Counter

Name

Sub Counter
C310080064

Name

Counter explanation

Cause & Solution


1. CE shortageneed CE expansion 2. Check alarm for more information Transmission problem Code shortage, need traffic balance, add new cell, second carrier Power shortage, need traffic balance, add new cell, second carrier Check the reason for RTWP increase, follow the interference shooting document CE shortageneed CE expansion CE shortageneed CE expansion 1. RCB OVERLOAD 2. DSP on RUB not config IP address Transmission problem

C310080063

Number of failed RRC connection preparation, NodeB C310080065

Number of failed RRC connection preparation,Due To Rl setup FAIL Rl setup FAIL Number of failed RRC connection preparation, Due To Rl setup expiry. Number of failed RRC connection preparation, Due To Codes Number of failed RRC connection preparation, Due To DL POWER Shortage Number of failed RRC connection preparation, Due To UL Interfere Number of failed RRC connection preparation, Due To UL CE Shortage Number of failed RRC connection preparation, Due To DL CE Shortage / Number of failed RRC connection preparation,Due To Iub RlSetup TbFail Number of failed RRC connection preparation,Due To Iub RlSetup TbCacFail Number of failed RRC connection preparation,Due To Iub UP Fail Number of failed RRC connection preparation, Due To CN Overload Due To Rl setup expiry

C310080067

CODE Shortage

C310080068 Number of failed RRC connection preparation, Due To Admission Control

DL POWER Shortage

C310080066

C310080069

UL Interference

C310080070

UL CE

C310080071 Number of failed RRC connection preparation, Due To RNC Internal Reasons

DL CE

C310080072

RL setup fail, Due to RNC

C310080077 Number of failed RRC connection preparation, Due To Trans

Iub Transmission Fail

C310080076

C310080078

Iub Transmission access Fail

Transmission problem

C310080079 Number of failed RRC connection preparation,Due To C310086447 CN

IUB Use Plane Fail

Transmission problem

C310086446

CN OVERLOAD

CN OVERLOAD

C310080167

Number of failed RRC connection access, due to Radio Interface Synch.

CAUSE: DSP Failed Other hardware problem RRC lodebalance strategy Radio interface failure has Timer for RL restore is to short Have Sent RRC Connection been attributed to some Setup, hardware failures(in sympathy SOLUTION: change hardware But do not received RRC with traffic as what happened Connection Setup Complete or to check if it is the problem at site selbone Park (BPC), Radio Link Restore 1. change the site CMP Nguboyenja (RRU)) 2. change resource shelf priority if it worked, need upgrade or repalce

C310080168

Number of failed RRC connection access, due to timeout of Uu interface

Have sent RRC Connection Setup, but do not receiced RRC Connection Setup Complete, but received Radio Link Restore

N/A

Meanwhile, UU interface may require some downtilt adjustments and that is what I will be doing for those cells with more than 100 RRC setup blocked due to UU interfac

C310080169

Number of failed RRC connection access, due to RNC Inner Reasons

Have sent RRC Connection Setup,but do not received RRC N/A Connection Setup Complete, because of RNC