You are on page 1of 4

Jurutera Perunding/Consulting Engineers

Design by:

Project:
Job:

WY

Data:
Shear load =
Tension force =
Moment =
Bolt Diameter =
Nos of bolt =

20
20
7
20
1

Col. Of bolt =
Row of bolt =

1
1

kN
kN
kNm
mm

1. Bolt Bearing Capacity Check


Applied shear on each bolt =
Pbb = dtppbb
=

200 kN

Provided weld length, l =


weld size, s =
Weld strength, pw =
Plate Thickness, tp =
End Distance, e =
Edge Distance, Lv =

20 kN

>20kN

OK

2. Column Flange Connected Part Bearing Capacity Check


Pbs = kbsdtppbs
=

92 kN

>20kN

OK

>20kN

OK

3. Bolt Shear Capacity Check


P s = p sA s
=

50.27 kN

4. Bolt Shear and Tension


Pnom = 0.8ptAt
=

60.32 kN
Applied tension on each bolt =
Fs/Ps + Ft/Pnom = 0.73

5. Capacity of Welding
Pweld = pwal
=

72.24 kN

6. Bearing Capacity of Plate


Pbs= kbsdtppbs
=
92 kN

20 kN
< 1.4 Shear and tension of bolt is safe.

where a = 0.7s
>20kN

But

OK

Pbs 0.5kbsetppbs
=

7. Plate Block shear capacity


Pr= 0.6pyt[Lv+Ke(Lt-kDt)]
-21.78 kN

<20kN

Failed

0 kN

Check by:
Rev
Date

80 mm
6 mm
215
10
0
0

OK
Failed

N/mm2
mm
mm
mm