You are on page 1of 7

VATECH

RIYADH, K.S.A.

SITE INSPECTION AND TEST RECORD


Description:

Contract No ::

LINE DIFFERENTIAL PROT. RELAY


TYPE : 7SD522

Record no. :

10531114/00

Customer:

End Client:

AL-BABTAIN

Sheet:

SEC-COA

Site:

Panel / Designation / Location no.:

1 of 7
Project no.:

S/S 8104-132/13.8KV
1.

2.

S/S 8104

GENERAL DATA AND INFORMATION


Bay No.

: ________________

Aux. Voltage

: _______________

Bay Name

: ________________

Serial No.

:________________

Manufacturer

: ________________

Order No.

: ________________

Draw. & Sh. No. : ________________

Conn. Diag. No. : ________________

Contact reset

No. of contacts

: _________________

: ________________

MECHANICAL CHECKS AND VISUAL INSPECTION:


ITEM

DESCRIPTION

Inspect for physical damage / defects.

Verify connections as per approved drawings.

Check tightness of all connections.

Check Ferrules

Check apparatus lists

CHECKED

3. ELECTRICAL TESTS:
ITEM

Tested by:
Name
Signature & Date :

DESCRIPTION

All contacts checked.

All output contacts resistance measured

Witnessed by:
Name:
Signature & Date :

CHECKED

VATECH
RIYADH, K.S.A.

SITE INSPECTION AND TEST RECORD


Description:

Contract No ::

LINE DIFFERENTIAL PROT. RELAY


TYPE : 7SD522
Customer:

End Client:

AL-BABTAIN
Site:

Record no. :

10531114/00
Sheet:

SEC-COA
Panel / Designation / Location no.:

2 of 7
Project no.:

S/S 8104-132/13.8KV

S/S 8104

4. DIFFERENTIAL PROTECTION TEST:


ADDRESS

1501 = ON
1601 = OFF
1131 = 0

1133 = 0
a) WHEN TESTING AN INDIVIDUAL UNIT, THE 400 OHMs RESISTANCE SHOULD BE
CONNECTED ACROSS PILOT WIRES TERMINALS.
b) RELAY SETTING :
PHASE

PICKUP

L1 E
L2 E
L3 - E
L1 L2
L2 L3
L3 L1

Tested by:
Name
Signature & Date :

Witnessed by:
Name:
Signature & Date :

DROP OFF

VATECH
RIYADH, K.S.A.

SITE INSPECTION AND TEST RECORD


Description:

Contract No ::

LINE DIFFERENTIAL PROT. RELAY


TYPE : 7SD522
Customer:

End Client:

AL-BABTAIN
Site:

Record no. :

10531114/00
Sheet:

SEC-COA
Panel / Designation / Location no.:

3 of 7
Project no.:

S/S 8104-132/13.8KV

S/S 8104

5. INTER TRIP TEST:


1541 = ON,

1542 = 0.1 Sec

APPLY THE CURRENT 1.1 TIMES THE PICK UP LEVEL & CHECK THE INTERTRIP
SEND CONTACT CLOSES.
PHASE

INTER TRIP
SEND CONTACT

DROPOUT
TIME

L1 E
L2 E
L3 - E
L1 L2
L2 L3
L3 L1

6. PILOT WIRE MONITORING TEST:


1601 = ON

1602 = MASTER AT _________________ END


SLAVE AT __________________ END

1603 = DIFFERENTUIAL BLOCK ON


1604 = 5Sec
1605 = 70 %
PILOT STATUS

DIFF. PROTN
BLOCK

PILOT OPEN
PILOT SHORT
PILOT CROSS

Tested by:
Name
Signature & Date :

Witnessed by:
Name:
Signature & Date :

PILOT ALARM
TIME = 5Secs

VATECH
RIYADH, K.S.A.

SITE INSPECTION AND TEST RECORD


Description:

Contract No ::

LINE DIFFERENTIAL PROT. RELAY


TYPE : 7SD522
Customer:

Record no. :

10531114/00
End Client:

AL-BABTAIN

Sheet:

SEC-COA

Site:

Panel / Designation / Location no.:

4 of 7
Project no.:

S/S 8104-132/13.8KV

S/S 8104

7. EXTERNAL LOCAL TRIP FACILITY (IF APPLICABLE)


ADDRESS

2101 = ON
2102 = 0.03 Secs
2103 = 0.2 Secs

INITIATE BINARY INPUT AND CHECK RELATED CONTACT FOR PICK -UP &
DROP-OFF.

TIME
PICK-UP
DROP-OFF

8. BACK UP O/C TIME PROTECTION:


2601 = ON

1501 = OFF

2603 = 4 =I > >


2604 = 0.1S = T- I > >

9. HIGH SET PICKUP TEST:


PHASE

PICKUP
CURRENT

L1 E
L2 E
L3 - E
L1 L2
L2 L3
L3 L1
Tested by:
Name
Signature & Date :

Witnessed by:
Name:
Signature & Date :

TIME AT 1.1 *
PICK UP

VATECH
RIYADH, K.S.A.

SITE INSPECTION AND TEST RECORD


Description:

Contract No ::

LINE DIFFERENTIAL PROT. RELAY


TYPE : 7SD522
Customer:

Record no. :

10531114/00
End Client:

AL-BABTAIN

Sheet:

SEC-COA

Site:

5 of 7

Panel / Designation / Location no.:

Project no.:

S/S 8104-132/13.8KV

S/S 8104

10. TIME DELAY UNIT:


(SET 2603 = 30 TO INIHIBIT HIGH SET DURING TESTING)
2612 = 2
2613 = 0.3

}
}

ONLY FOR DEFINITE TIME FUNCTION.

2614 = 1.5A

ONLY FOR INVERSE TIME FUNCTION.

2615 = 0.5 Secs}


2616 = WITH OUT HARMONICS

CURVE AT 3 * SETTING
PHASE

DIFINITE

NORMAL
INVERSE

L1 E
L2 E
L3 E
L1 L2
L2 L3
L3 L1

Tested by:
Name
Signature & Date :

Witnessed by:
Name:
Signature & Date :

VERY
INVERSE

EXTREAMLY
INVERSE

VATECH
RIYADH, K.S.A.

SITE INSPECTION AND TEST RECORD


Description:

Contract No ::

LINE DIFFERENTIAL PROT. RELAY


TYPE : 7SD522
Customer:

End Client:

AL-BABTAIN

Record no. :

10531114/00
Sheet:

SEC-COA

Site:

Panel / Designation / Location no.:

6 of 7
Project no.:

S/S 8104-132/13.8KV

S/S 8104

11. SWITCH ON TO FAULT TEST:


2621 = I > > UNDELAYED C.B CLOSE BINARY INPUT ENERGISED.
APPLY CURRENT > I HIGH SET SETTING AND CHECK RELAY OPERATES
INSTANTANOUSLY BYPASSING 2604 = 0.1 Sec
FAULT

OPERATIVE TIME

L1 E
L2 E
L3 - E
L1 L2
L2 L3
L3 L1

12. COMMISSSIONG USING PRIMARY TEST:

MEASURED VALUE

SET VALUE

CX =
RX =

Tested by:
Name
Signature & Date :

Witnessed by:
Name:
Signature & Date :

VATECH
RIYADH, K.S.A.

SITE INSPECTION AND TEST RECORD


Description:

Contract No ::

LINE DIFFERENTIAL PROT. RELAY


TYPE : 7SD522
Customer:

End Client:

AL-BABTAIN
Site:

Sheet:

SEC-COA
Panel / Designation / Location no.:

S/S 8104-132/13.8KV

I1
4120
I2
ALPHA
Id
RECEIVE
LEVEL

13. REMARKS:

Tested by:
Name
Signature & Date :

7 of 7
Project no.:

S/S 8104

AFTER ENERGISING CHECK THE FOLLOWING:

4130

Record no. :

10531114/00

Witnessed by:
Name:
Signature & Date :