ANALISIS DINAMICO MODAL ESPECTRAL


INFORMACION:
Zona 3 ICA:

Z=0.4

Factor de Uso:

U=1

Suelo tipo S1:

S=1, Tp(S)=0.4

Coeficiente de Reduccin: DUAL

R=7

PERIODO FUNDAMENTAL DE VIBRACION:


hn

T= Ct

Ct = 60sistema dual
Hn = 17 m
T=0.283333 s

FACTOR DE AMPLIFICACION SISMICA:


C = 2.5

Tp
T )

GRAFICO DEL ESPECTRO SEGN LA NORMA


T
0.00
0.05
0.10
0.15
0.20
0.25
0.30
0.35
0.40
0.45
0.50
0.55
0.60
0.65
0.70
0.75
0.80
0.85
0.90
0.95
1.00

C
2.50
2.50
2.50
2.50
2.50
2.50
2.50
2.50
2.50
2.22
2.00
1.82
1.67
1.54
1.43
1.33
1.25
1.18
1.11
1.05
1.00

EC-231 INGENIERIA ANTISIMICA Pgina 2

Sa
1.40
1.40
1.40
1.40
1.40
1.40
1.40
1.40
1.40
1.24
1.12
1.02
0.93
0.86
0.80
0.75
0.70
0.66
0.62
0.59
0.56

UNIVERSIDAD NACIONAL DE INGENIERA


FACULTAD DE INGENIERA CIVIL
1.05
1.10
1.15
1.20
1.25
1.30
1.35
1.40
1.45
1.50
1.55
1.60
1.65
1.70
1.75
1.80
1.85
1.90
1.95
2.00
2.05
2.10

0.95
0.91
0.87
0.83
0.80
0.77
0.74
0.71
0.69
0.67
0.65
0.63
0.61
0.59
0.57
0.56
0.54
0.53
0.51
0.50
0.49
0.48

0.53
0.51
0.49
0.47
0.45
0.43
0.41
0.40
0.39
0.37
0.36
0.35
0.34
0.33
0.32
0.31
0.30
0.29
0.29
0.28
0.27
0.27

GRAFICO:

ESPECTRO DE NORMA
1.60
1.40
1.20
1.00
Sa

0.80
0.60
0.40
0.20
0.00
0.00

0.50

1.00

1.50

2.00

PROCEDIMIENTO UTILIZANDO PROGRAMA ETABS

EC-231 INGENIERIA ANTISIMICA Pgina 3

2.50

UNIVERSIDAD NACIONAL DE INGENIERA


FACULTAD DE INGENIERA CIVIL

Se procede a introducir el espectro de la norma

Luego creamos un nuevo caso de carga en ambas direcciones

Modificamos la direccin del sismo

EC-231 INGENIERIA ANTISIMICA Pgina 4

UNIVERSIDAD NACIONAL DE INGENIERA


FACULTAD DE INGENIERA CIVIL

RESULTADOS
VERIFICACION DE CORTANTE EN LA BASE DINAMICO CON EL
ESTATICO:
DIRECCION X

Load
Case/Co
mbo

Locatio
n

Story1

SX2

Bottom

Story1

SXdinami
co Max

Bottom

Story

% V dinmico con
respecto V esttico

VX

VY

tonf

tonf
811.937
1
541.566
2

tonf

67%

V dinmico
min
facto
r

<
80%
649.5
5
1.25

EC-231 INGENIERIA ANTISIMICA Pgina 5

0
14.072

ES NECESARIO ESCALAR EL
CORTANTE DINAMICO

ton

UNIVERSIDAD NACIONAL DE INGENIERA


FACULTAD DE INGENIERA CIVIL

DIRECCION Y

Story

Load
Case/Co
mbo

Locatio
n

VX

VY

tonf

tonf

tonf

Story1

SY2

Bottom

Story1

Sydinamic
o Max

Bottom

14.072

% V dinmico con respecto


V esttico

72%

<
80%

ES NECESARIO ESCALAR EL
CORTANTE DINAMICO

649.5
5
1.25

V dinmico min
factor

811.937
1
588.009
5

ton

TABLA DE FUERZAS CORTANTES E FUERZAS INERCIALES


ESCALADOS:
DIRECCION X

Load
Case/Co
mbo

Locatio
n

Story6

SXdinami
co Max

Story5

Vx
escalado(T FX(ton)
on)

VX

VY

tonf

tonf

Bottom

129.625

3.3591

162.03

162.03

SXdinami
co Max

Bottom

257.063
2

6.6425

321.33

159.30

Story4

SXdinami
co Max

Bottom

361.863
3

9.3703

452.33

131.00

Story3

SXdinami
co Max

Bottom

445.690
1

11.5506

557.11

104.78

Story2

SXdinami
co Max

Bottom

508.442
8

13.1927

635.55

78.44

Story1

SXdinami
co Max

Bottom

541.566
2

14.072

676.96

41.40

Story

EC-231 INGENIERIA ANTISIMICA Pgina 6

UNIVERSIDAD NACIONAL DE INGENIERA


FACULTAD DE INGENIERA CIVIL

DIRECCION Y

Load
Case/Co
mbo

Locatio
n

FY (ton)

tonf

Vy
escalado
(Ton)

Story6

Sydinamic
o Max

3.3224

137.499

171.87

171.87

Story5

Bottom

6.6426

276.125
6

345.16

173.28

Sydinamic
o Max

Bottom

9.3992

390.817
7

488.52

143.37

Story3

Sydinamic
o Max

Bottom

11.594

482.720
3

603.40

114.88

Story2

Sydinamic
o Max

Bottom

13.2273

551.581
6

689.48

86.08

Story1

Sydinamic
o Max

Bottom

14.072

588.009
5

735.01

45.53

VX

VY

tonf

Bottom

Sydinamic
o Max

Story4

Story

VERIFICACION DE DESPLAZAMIENTOS:
DIRECCION X

Story

Load
Case/Co
mbo

Label

Story6

SXdinamic
o Max

30

Max Drift
0.0019477
0.000371
X
5

0.007

Story5

SXdinamic
o Max

30

Max Drift
0.0027562
0.000525
X
5

0.007

Story4

SXdinamic
o Max

30

Max Drift
0.0035437
0.000675
X
5

0.007

Story3

SXdinamic
o Max

30

Max Drift
0.0041632
0.000793
X
5

0.007

Story2

SXdinamic
o Max

30

Max Drift
X

0.0044625

0.007

Story1

SXdinamic
o Max

51

Max Drift
0.0029767
0.000567
X
5

0.007

Item

EC-231 INGENIERIA ANTISIMICA Pgina 7

Drift

0.00085

0.75R

ADM.

UNIVERSIDAD NACIONAL DE INGENIERA


FACULTAD DE INGENIERA CIVIL

Observamos que se cumplen todos niveles el desplazamiento

DIRECCION Y

Story
Story6

Load
Case/Co
mbo
Sydinamic
o Max

Label

Item

Drift

0.75R

ADM.

49

Max Drift
Y

0.000368

0.00193
2

0.007

Story5

Sydinamic
o Max

49

Max Drift
Y

0.000515

0.00270
375

0.007

Story4

Sydinamic
o Max

49

Max Drift
Y

0.000654

0.00343
35

0.007

Story3

Sydinamic
o Max

49

Max Drift
Y

0.000764

0.00401
1

0.007

Story2

Sydinamic
o Max

49

Max Drift
Y

0.000829

0.00435
225

0.007

Story1

Sydinamic
o Max

49

Max Drift
Y

0.000582

0.00305
55

0.007

Observamos que cumplen todos los niveles en desplazamiento


JUNTA DE SEPARACION SISMICA:
Como se observa del plano de planta en la direccin x se encuentra el
lmite de propiedad
De la tabla de desplazamientos mximos en la direccin x escogemos
el mayor y luego lo multiplicamos por la altura del nivel:
0.00446253 100 = 1.34 cm

S = 21.34/3 = 0.89 cm
S/2 = (3+0.004 (1700-500))/2 = 3.9 cm
S/2 = 1.5 cm

Escogemos el mayor de todos:


S = 3.9 cm <> 1

EC-231 INGENIERIA ANTISIMICA Pgina 8

UNIVERSIDAD NACIONAL DE INGENIERA


FACULTAD DE INGENIERA CIVIL

EC-231 INGENIERIA ANTISIMICA Pgina 9