You are on page 1of 9

Downstream design

Single link from the OLT ith to an ONT


Laser diode
The OLD 3355-49C1-SC (Optocom Corporation) is a hermetically
sealed CWDM 1490nm InGaAsP/ InP D FB laser diode module in a
small coaxial type package
Wavelength Division Multiplexing (WDM)1 & 2
WDM-GP of QAMnet, LLC is available in either a rugged
module with SC/APC connectors or unpackaged device form.
ADP
The JDSU RXA M DPGX
088 XX-000 series fiber
pigtail receivers
incorporate a 60-front-
illuminated avalanche
photodiode (APD)
packaged with a
transimpedance
amplifier (TIA) and a
single-mode fiber
pigtail, designed to
operate up to 2.5 Gbps
Optical fiber
• Draka’ s Enhanced Single-
Mode Fiber (ESMF) provides
improved performance
across the entire 1260 nm to
1625 nm wavelength
spectrum.
• It has a low dispersion in
the 1310 nm window and
low attenuation in the 1383
nm water-peak region to
allow use of the extended
band (1360 nm to 1460 nm).
Optical splitter

• The OFS MPO splitter


module is available in
multiple configurations to
meet customer
requirements. The OFS
splitters also utilize FHD
technology, insuring
better thermal stability.
• The splitter module meets
Telcordia GR-1221-CORE
and GR-1209-CORE
requirements.
Optical connector
 

Specification: FC/PC SM Connector


• Material: zirconia ferrule (ZrO2)
• Insertion loss: <0.2dB
• Return loss: >55dB
• Service life: >1000 times
• Temperature range: -40°~85°
Performance
 

For downstream, GEPON has:

• Data Rate 1.25 Gbps.


• Transmission distance: 20 km (maximum).
• Working in single mode fiber.
• Wavelength use for downstream is 1490 nm.
• Light source is laser diode.
• Receiver APD-TIA.
Link-power-budget calculation
Power Value Unit
Laser output 4 dBm
Receiver’s sensitivity (MDP) -34 dBm
Power loss
Connectors 8x0.2 1.6 * dB
Fibers 20x0.25 5 * dB
PON-splitter 1x16.5 16.3 * dB
Temperature derating 20x0.05 1 dB
Splice 2.0 * dB
WDM 2x1.1 2.2 * dB
----------------------------------------------------------------------------------------------------------
Total loss (worst case) 1.6+5+16.5+1+2+2.2 28.1 dB
Total loss (best case) 1.6+5+16.5+2+2.2 (*) 27.1 dB
----------------------------------------------------------------------------------------------------------
Power margin (worst case) 4 - (-34) – 28.1 9.9 dB
Power margin (best case) 3 - (-34) – 27.1 10.9 dB

 
 The GEPON optical transmission system downstream is feasible!