Flange Leakage Check

Sr.
No.

Line No.

Node
No.

Nozzle Details
Size
(Inch)

Rating
(#)

Pressure

Temperature

Axial Force

Resultant
Moment

Mean Dia. of
Gasket Contact
face

Equivalent
Pressure

Allowable
Pressure

Condition /
Case

Result
(Flange Leakage
Check)

(Kg/cm2g)

(Deg F)

(N)

(N-m)

(mm)

(psig)

(psig)

10

14

150

11.6

368

2021

2256

389

195

210

Case -1

PASS

10

14

150

9.6

341

1798

2021

389

164

218

Case -2

PASS

10

14

150

0.5

374

2098

2325

389

39

208

Case -3

PASS

100

10

150

11.6

368

5940

4965

302

309

410

Case -1

PASS

100

10

150

9.6

341

5284

6011

302

307

218

Case -2

FAIL

100

10

150

0.5

374

5679

4822

302

147

208

Case -3

PASS

150

10

150

11.6

368

17

851

302

187

210

Case -1

PASS

150

10

150

9.6

341

10

760

302

157

218

Case -2

PASS

150

10

150

0.5

374

337

848

302

30

208

Case -3

PASS

Notes :
1) Gasket dimensions are as per ANSI B 16.20
2) Allowable Pressure is as per "Pressure-Temperature" Chart from ANSI B16.5.
3) This table is prepared based on ASME Section III, Paragraph NC-3658.1.
4) All values of Static output results (Force & Moments) for different cases are considered for the calculation.
6) The formula used to calculate the Equivalent Pressure is as follows :
Peqv = Pd + 4*F/3.14*G2 + 16*M/3.14*G3
Pd = Internal Pressure
where ;
F = Axial Force
G = Mean Diameter of Gasket
M = Resultant Bending Moment
7) Units have been converted suitably.
Case -1
Case -2
Case -3

Design Case
Operating Case
Occasional Case