OptiX OSN 3500/2500/1500

Configuration Guide Contents

Contents

3 Configuring Ethernet Services ................................................................................................3-1


3.1 Configuring the Point-to-Point EPL Service .................................................................................................3-2
3.1.1 Engineering Requirements...................................................................................................................3-2
3.1.2 Engineering Planning...........................................................................................................................3-2
3.1.3 Configuration Process(by Station) .......................................................................................................3-6
3.1.4 Configuration Process (by Trail)........................................................................................................3-15
3.2 Configuring the PORT Shared EPL Service................................................................................................3-18
3.2.1 Engineering Requirements.................................................................................................................3-18
3.2.2 Engineering Planning.........................................................................................................................3-18
3.2.3 Configuration Process(by Station) .....................................................................................................3-21
3.2.4 Configuration Process (by Trail)........................................................................................................3-26
3.3 Configuring the VCTRUNK Shared EPL Service ......................................................................................3-29
3.3.1 Engineering Requirements.................................................................................................................3-29
3.3.2 Engineering Planning.........................................................................................................................3-30
3.3.3 Configuration Process(by Station) .....................................................................................................3-33
3.3.4 Configuration Process (by Trail)........................................................................................................3-38
3.4 Configuring the EPLn Service ....................................................................................................................3-42
3.4.1 Engineering Requirements.................................................................................................................3-42
3.4.2 Engineering Planning.........................................................................................................................3-42
3.4.3 Configuration Process(by Station) .....................................................................................................3-45
3.4.4 Configuration Process (by Trail)........................................................................................................3-54

Issue 01 (2006-09-20) Huawei Technologies Proprietary i


OptiX OSN 3500/2500/1500
Configuration Guide Figures

Figures

Figure 3-1 Ethernet service networking and port allocation...............................................................................3-3


Figure 3-2 Board layout of NE1.........................................................................................................................3-3
Figure 3-3 Board layout of NE5.........................................................................................................................3-4

Figure 3-4 Service configuration diagram..........................................................................................................3-4


Figure 3-5 SDH timeslot allocation for Ethernet services..................................................................................3-6
Figure 3-6 Ethernet service networking and port allocation.............................................................................3-19

Figure 3-7 Service configuration diagram........................................................................................................3-19


Figure 3-8 Timeslot allocation diagram............................................................................................................3-21
Figure 3-9 Ethernet service networking and port allocation.............................................................................3-30

Figure 3-10 Board layout of NE2 and NE3......................................................................................................3-31


Figure 3-11 Service configuration diagram ......................................................................................................3-31
Figure 3-12 SDH timeslot allocation for Ethernet services..............................................................................3-32

Figure 3-13 Ethernet service networking and port allocation...........................................................................3-42


Figure 3-14 Board layout of NE2 and NE3......................................................................................................3-43
Figure 3-15 Board layout of NE4.....................................................................................................................3-43

Figure 3-16 Service configuration diagram......................................................................................................3-44


Figure 3-17 SDH timeslot allocation for Ethernet services..............................................................................3-45

Issue 01 (2006-09-20) Huawei Technologies Proprietary iii


OptiX OSN 3500/2500/1500
Configuration Guide Tables

Tables

Table 3-1 Mapping between Ethernet boards and Ethernet services ..................................................................3-1
Table 3-2 Service requirement of each station....................................................................................................3-2
Table 3-3 Ethernet service connection table .......................................................................................................3-5

Table 3-4 Process of point-to-point EPL service configuration ..........................................................................3-6


Table 3-5 Process of creating point-to-point EPL service (by trail)..................................................................3-15
Table 3-6 Ethernet service connection table .....................................................................................................3-20

Table 3-7 Process of PORT shared EPL service configuration.........................................................................3-21


Table 3-8 Process of creating PORT-shared EPL service (by trail) ..................................................................3-26
Table 3-9 Ethernet service connection table .....................................................................................................3-32

Table 3-10 Process of VCTRUNK shared EPL service configuration..............................................................3-33


Table 3-11 Process of creating VCTRUNK-shared EPL service (by trail) .......................................................3-39
Table 3-12 Ethernet service connection table ...................................................................................................3-44

Table 3-13 Forwarding filter table ....................................................................................................................3-45


Table 3-14 Process of EPLn service configuration...........................................................................................3-46
Table 3-15 Process of creating EPLn service (by trail).....................................................................................3-54

Issue 01 (2006-09-20) Huawei Technologies Proprietary v


OptiX OSN 3500/2500/1500
Configuration Guide 3 Configuring Ethernet Services

3 Configuring Ethernet Services

About This Chapter

This chapter describes the process of configuring Ethernet private line (EPL) and Ethernet
private local area network (EPLn) services on the T2000, and related engineering
requirements and engineering information as well.
The configuration of Ethernet virtual private line (EVPL) and Ethernet virtual private local
area network (EVPLn) will be described with resilient packet ring (RPR) in Chapter 4.
Through this example, you can learn how to configure EPL and other similar services.
The following table is a mapping table which associates the Ethernet services to the Ethernet
boards of the OptiX OSN 3500/2500/1500.

Table 3-1 Mapping between Ethernet boards and Ethernet services


Ethernet ser EPL EVPL EPLn EVPLn
vices
Board

EFT8 Supported Not supported Not supported Not supported


EFT4 Supported Not supported Not supported Not supported
EGT2 Supported Not supported Not supported Not supported
EFS4 Supported Supported Supported Supported
EFS0 Supported Supported Supported Supported
EGS2 Supported Supported Supported Supported

In this chapter, the OptiX OSN 3500 product is taken as an example. For the OptiX OSN 2500 and the
OptiX OSN 1500A/B, service configuration is performed in the same way. The only difference is that
the boards of the OptiX OSN 2500 and the OptiX OSN 1500A/B are inserted in different slots.

The following table lists the contents of this chapter.

Issue 01 (2006-09-20) Huawei Technologies Proprietary 3-1


OptiX OSN 3500/2500/1500
3 Configuring Ethernet Services Configuration Guide

Title Description

3.1 Configuring the Point-to-Point Describes how to configure the point-to-point EPL
EPL Service services on the T2000
3.2 Configuring the PORT Shared Describes how to configure the port shared EPL
EPL Service services on the T2000
3.3 Configuring the VCTRUNK Describes how to configure the VCTRUNK shared
Shared EPL Service EPL services on the T2000
3.4 Configuring the EPLn Service Describes how to configure the EPLn services on the
T2000

3.1 Configuring the Point-to-Point EPL Service


3.1.1 Engineering Requirements
The two companies A and B in NE1 need to transmit data services to NE5 through
multi-service transport platform (MSTP) equipment. The services of A and B are required to
be completely isolated. Both A and B provide 100 Mbit/s Ethernet electrical interfaces. A
requires 10 Mbit/s bandwidth, B requires 40 Mbit/s bandwidth, and their interconnected
equipment does not support VLAN, as shown in Table 3-2.

Table 3-2 Service requirement of each station


User Service Source station (number Sink station (number of Bandwidth
requirement of ports occupied) ports occupied)

A Point-to-point NE1 (1) NE5 (1) 10 Mbit/s


B Point-to-point NE1 (1) NE5 (1) 40 Mbit/s

3.1.2 Engineering Planning


The engineering design department conducts planning based on the above requirements and
the engineering information described in Chapter 1, and outputs the following engineering
information:
z Networking Diagram
z Board Information of Each NE
z Service Configuration Diagram of Each NE
z Timeslot Allocation Diagram

Networking Diagram
Figure 3-1 shows the Ethernet service networking and port allocation.

3-2 Huawei Technologies Proprietary Issue 01 (2006-09-20)


OptiX OSN 3500/2500/1500
Configuration Guide 3 Configuring Ethernet Services

Figure 3-1 Ethernet service networking and port allocation

A B

PORT1 PORT2

T2000

NE1 STM-4 two-fiber


bidirectional non-
protection chain NE5
STM-16 two-fiber
NE2 bidirectional MSP ring NE4

PORT1 PORT2

NE3
A B
VC-Trunk

Board Information of Each NE


Ethernet boards need to be added according to the added service type and traffic volume. NE1
and NE5 are added with one N1EFS4 board respectively. Other NEs remain unchanged.
Figure 3-2 and Figure 3-3 show the board layout of NE1 and NE5 respectively.

Figure 3-2 Board layout of NE1

S S S S S S S S S S S S S S S S S S S
1 2 2 2 2 2 2 2 2 2 2 3 3 3 3 3 3 3 3
9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7
D75S
D75S
D75S
D75S
D75S
D75S

PIU
PIU

AUX

FAN FAN FAN

S S S S S S S S S S S S S S S S S S
1 2 3 4 5 6 7 8 9 1 1 1 1 1 1 1 1 1
0 1 2 3 4 5 6 7 8
GXCSA

GXCSA

N1EFS4
PQ1
PQ1

GSCC
GSCC
PQ1
PQ1

SL16

SL16

Issue 01 (2006-09-20) Huawei Technologies Proprietary 3-3


OptiX OSN 3500/2500/1500
3 Configuring Ethernet Services Configuration Guide

Figure 3-3 Board layout of NE5

S S S S S S S S S S S S S S S S S S S
1 2 2 2 2 2 2 2 2 2 2 3 3 3 3 3 3 3 3
9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7

D75S
D75S

C34S
PIU

PIU

AUX
FAN FAN FAN

S S S S S S S S S S S S S S S S S S
1 2 3 4 5 6 7 8 9 1 1 1 1 1 1 1 1 1
0 1 2 3 4 5 6 7 8

N1EFS4
GXCSA

GXCSA

GSCC
GSCC
PQ1

SL4

PL3

Service Configuration Diagram of Each NE


Figure 3-4shows the service configuration diagram of NE1 and NE5.

Figure 3-4 Service configuration diagram

PORT VCTRUNK VCTRUNK PORT

PORT1 PORT1
A A
10M VCTRUNK1 SDH VCTRUNK1 10M
VC4-4:VC12-1~VC12-5 VC4-4:VC12-1~VC12-5
PORT2 PORT2
B B
VCTRUNK2 VCTRUNK2
40M VC4-1:VC-3-1
40M
VC4-1:VC-3-1

NE1
NE5

Only VC4-4 can be used when the N2EFS0 and N1EFS4 boards are bounded with a path at VC-12 level.

Table 3-3 shows the Ethernet service connection table.

3-4 Huawei Technologies Proprietary Issue 01 (2006-09-20)


OptiX OSN 3500/2500/1500
Configuration Guide 3 Configuring Ethernet Services

Table 3-3 Ethernet service connection table

Service A B
Attribute

Source NE NE1 NE1


Source board - port 13-N1EFS4-1 13-N1EFS4-2
Source Timeslot range VC4-4: VC12-1–VC12-5 VC4-1: VC3-1
Source VCTRUNK VCTRUNK1 VCTRUNK2
Working mode of source PORT Auto negotiation Auto negotiation
TAG flag of source PORT Access Access
VLAN ID of source PORT 1 2
Bound bandwidth 5 x VC-12 1 x VC-3
Sink NE NE5 NE5
Sink board - port 15-N1EFS4-1 15-N1EFS4-2
Sink Timeslot range VC4-4: VC12-1–VC12-5 VC4-1: VC3-1
Sink VCTRUNK VCTRUNK1 VCTRUNK2
Working mode of sink PORT Auto negotiation Auto negotiation
TAG flag of sink PORT Access Access
VLAN ID of sink PORT 1 2

Timeslot Allocation Diagram


Figure 3-5shows the SDH timeslot allocation.

Issue 01 (2006-09-20) Huawei Technologies Proprietary 3-5


OptiX OSN 3500/2500/1500
3 Configuring Ethernet Services Configuration Guide

Figure 3-5 SDH timeslot allocation for Ethernet services

Ring
Station NE1 NE2 NE3 NE4 NE1
Timeslot 12-SL16-1 7-SL16-1 12-SL16-1 7-SL16-1 12-SL16-1 7-SL16-1 12-SL16-1 7-SL16-1
VC-12: 1-5
VC4-3
13-EFS4: VC4-4

VC-3: 1
VC4-4
13-EFS4: VC4-1

Chain
Station NE4 NE5
Timeslot 13-SL4-1 7-SL4-1
VC-12: 1-5
VC4-3
15-EFS4: VC4-4

VC-3: 1
VC4-4
15-EFS4: VC4-1

Forward
Add/Drop

3.1.3 Configuration Process(by Station)


Table 3-4 shows the process of configuring the point-to-point EPL service on the T2000.

Table 3-4 Process of point-to-point EPL service configuration

Procedure Description Remarks

1 Creating a board
2 Configuring Ethernet interfaces
3 Configuring bound paths
4 Creating the point-to-point EPL service
5 Configuring committed access rate (CAR) Optional
6 Configuring the cross-connect from Ethernet boards to SDH
line boards

Creating a Board
Follow the steps below to create a board.
Step 1 In the Main Topology, double click the NE1 icon to open the NE panel.
Step 2 Right click slot 13 according to the board layout shown in Figure 3-2, and select N1EFS4
from the shortcut menu.

Step 3 Make sure that the N1EFS4 board has been configured in slot 13 and click .

3-6 Huawei Technologies Proprietary Issue 01 (2006-09-20)


OptiX OSN 3500/2500/1500
Configuration Guide 3 Configuring Ethernet Services

Step 4 Repeat steps 1–3 to create the Ethernet board of NE5. Figure 3-3 shows the board layout of
NE5.
----End

Configuring NE1 Data

See the T2000 online help for the meaning of each parameter during service configuration.

Step 1 Configuring Ethernet interfaces


1. Right click the NE1 icon in the Main Topology, and select NE Explorer.
2. Select 13-N1EFS4 from the Object Tree and Configuration > Ethernet Interface
Management > Ethernet Interface from the Function Tree, and then click .
3. Select External Port, and set as follows. Select the Basic Attributes tab. Set the
Enabled/Disabled of the PORT1 and PORT2 to Enabled. Click Apply.

4. Select the Tag Attribute tab. Set the TAG of the PORT1 and PORT2 to Access. Other
items adopt the default value. Click Apply.

Step 2 Configuring bound paths


1. Select the Bound Path tab from the Internal Port page.
2. Click Configuration. Then, the Bound Path Configuration dialog box is displayed.
3. To set bound paths for VCTRUNK1, set as follows in the dialog box.
− Configurable Ports: VCTRUNK1
− Level: VC12-xv
− Direction: Bidirectional
− Available Resources: VC4-4
− Select VC12-1 to VC12-5 from the Available Timeslots one by one, and then click
.

Issue 01 (2006-09-20) Huawei Technologies Proprietary 3-7


OptiX OSN 3500/2500/1500
3 Configuring Ethernet Services Configuration Guide

4. To set a bound path for VCTRUNK2, set as follows in the dialog box.
− Configurable Ports: VCTRUNK2
− Level: VC3-xv
− Direction: Bidirectional
− Available Resources: VC4-1
− Select VC3-1 from the Available Timeslots, and then click .
− Click OK.

Step 3 Creating the point-to-point EPL service


1. Select 13-N1EFS4 from the Object Tree and select Configuration > Ethernet Service
> Ethernet Line Service from the Function Tree.
2. Click New, and the Create Ethernet Line Service dialog box is displayed.
3. According to Figure 3-4, set as follows to create the EPL service for A.
− Service Type: EPL
− Service Direction: Bidirectional
− Source Port: PORT1
− Sink Port: VCTRUNK1
− Click Apply.

3-8 Huawei Technologies Proprietary Issue 01 (2006-09-20)


OptiX OSN 3500/2500/1500
Configuration Guide 3 Configuring Ethernet Services

4. Repeat 3 to create the EPL service for B. Set as follows in the dialog box.
− Service Type: EPL
− Service Direction: Bidirectional
− Source Port: PORT2
− Sink Port: VCTRUNK2
− Click OK.
Step 4 Configuring CAR (optional)
1. Select 13-N1EFS4 from the Object Tree and select Configuration > QoS
Management > Flow Management from the Function Tree, and then the CAR tab.
2. Click New, and the Create CAR dialog box is displayed.
3. Set as follows in the dialog box.
− CAR ID: 1
− Enabled/Disabled: Enabled
− Committed Information Rate(kbit/s): 10 Mbit/s
− Committed Burst Size(kbyte): 0
− Peak Information Rate(kbit/s): 20 Mbit/s

Issue 01 (2006-09-20) Huawei Technologies Proprietary 3-9


OptiX OSN 3500/2500/1500
3 Configuring Ethernet Services Configuration Guide

− Maximum Burst Size(kbyte): 0


− Click Apply.

4. Repeat 3 to set as follows in the dialog box:


− CAR ID: 2
− Enabled/Disabled: Enabled
− Committed Information Rate(kbit/s): 40 Mbit/s
− Committed Burst Size(kbyte): 0
− Peak Information Rate(kbit/s): 50 Mbit/s
− Maximum Burst Size(kbyte): 0
− Click OK.
5. Select the Flow tab.
6. Set as follows in the dialog box for PORT1 and VCTRUNK1.
− Bound CAR: 1
− Click Apply.
7. Repeat 6 to set the bound CAR for port 2 and VCTRUNK2.
− Bound CAR: 2
− Click Apply.

Step 5 Configuring the cross-connect from Ethernet boards to SDH line boards

3-10 Huawei Technologies Proprietary Issue 01 (2006-09-20)


OptiX OSN 3500/2500/1500
Configuration Guide 3 Configuring Ethernet Services

1. Select NE1 from the Object Tree.


2. Select Configuration > SDH Service Configuration from the Function Tree.
3. Click Create, and the Create SDH Service dialog box is displayed.
4. Set as follows in the dialog box.
− Level: VC12
− Direction: Bidirectional
− Source Slot: 13-N1EFS4-1(SDH-1)
− Source VC4: VC4-4
− Source Timeslot Range(e.g.1,3-6): 1–5
− Sink Slot: 7-N2SL16-1(SDH-1)
− Sink VC4: VC4-3
− Sink Timeslot Range(e.g.1,3-6): 1–5
− Activate Immediately: Yes
− Click Apply.

5. Repeat 4 to set as follows in the dialog box.


− Level: VC3
− Direction: Bidirectional
− Source Slot: 13-N1EFS4-1(SDH-1)

Issue 01 (2006-09-20) Huawei Technologies Proprietary 3-11


OptiX OSN 3500/2500/1500
3 Configuring Ethernet Services Configuration Guide

− Source VC4: VC4-1


− Source Timeslot Range(e.g.1,3-6): 1
− Sink Slot: 7-N2SL16-1(SDH-1)
− Sink VC4: VC4-4
− Sink Timeslot Range(e.g.1,3-6): 1
− Activate Immediately: Yes
− Click Apply.
----End

Configuring NE5 Data

The data configuration of NE5 is the same as that of NE1, except that some parameters are different.

Step 1 Configuring Ethernet interfaces

1. Click the NE switching shortcut icon . Select NE5, and click OK.
2. Select 15-N1EFS4 from the Object Tree and select Configuration > Ethernet
Interface Management > Ethernet Interface from the Function Tree. Then, click
.
3. Select External Port, and set as follows.
− Select the Basic Attributes tab. Set the Enabled/Disabled of the PORT1 and PORT2
to Enabled. Click Apply.
− Select the TAG Attribute tab. Set the TAG of the PORT1 and PORT2 to Access.
− Other items adopt the default value. Click Apply.
Step 2 Configuring bound paths
1. Select the Bound Path tab from the Internal Port page.
2. Click Configuration, and the Bound Path Configuration dialog box is displayed.
3. To set bound paths for VCTRUNK1, set as follows in the dialog box.
− Configurable Ports: VCTRUNK1
− Level: VC12-xv
− Direction: Bidirectional
− Available Resources: VC4-4
− Select VC12-1 to VC12-5 from the Available Timeslots one by one, and then click
.
4. To set a bound path for VCTRUNK2, set as follows in the dialog box.
− Configurable Ports: VCTRUNK2
− Level: VC3-xv
− Direction: Bidirectional
− Available Resources: VC4-1
− Select VC3-1 from the Available Timeslots, and then click .
− Click OK.
Step 3 Creating the point-to-point EPL service

3-12 Huawei Technologies Proprietary Issue 01 (2006-09-20)


OptiX OSN 3500/2500/1500
Configuration Guide 3 Configuring Ethernet Services

1. Select Configuration > Ethernet Service > Ethernet Line Service from the Function
Tree.
2. Click New and the Create Ethernet Line Service dialog box is displayed.
3. According to Figure 3-4 set as follows to create the EPL service for A.
− Service Type: EPL
− Service Direction: Bidirectional
− Source Port: PORT1
− Sink Port: VCTRUNK1
− Click Apply.
4. Repeat 3 to create the EPL service for B. Set as follows in the dialog box.
− Service Type: EPL
− Service Direction: Bidirectional
− Source Port: PORT2
− Sink Port: VCTRUNK2
− Click OK.
Step 4 Configuring CAR (optional)
1. Select Configuration > QoS Management > Flow Management from the Function
Tree and select the CAR tab.
2. Click New and the Create CAR dialog box is displayed.
3. Set as follows in the dialog box.
− CAR ID: 1
− Enabled/Disabled: Enabled
− Committed Information Rate(kbit/s): 10 Mbit/s
− Committed Burst Size(kbyte): 0
− Peak Information Rate(kbit/s): 20 Mbit/s
− Maximum Burst Size(kbyte): 0
− Click Apply.
4. Repeat 3 to set as follows in the dialog box.
− CAR ID: 2
− Enabled/Disabled: Enabled
− Committed Information Rate(kbit/s): 40 Mbit/s
− Committed Burst Size(kbyte): 0
− Peak Information Rate(kbit/s): 50 Mbit/s
− Maximum Burst Size(kbyte): 0
− Click OK.
5. Select the Flow tab.
6. Set the bound CAR for PORT1 and VCTRUNK1.
− Bound CAR: 1
− Click Apply.
7. Repeat 6 to set the bound CAR for PORT 2 and VCTRUNK2.
− Bound CAR: 2
− Click Apply.

Issue 01 (2006-09-20) Huawei Technologies Proprietary 3-13


OptiX OSN 3500/2500/1500
3 Configuring Ethernet Services Configuration Guide

Step 5 Configuring the cross-connect from Ethernet boards to SDH line boards
1. Select NE5 from the Object Tree.
2. Select Configuration > SDH Service Configuration from the Function Tree.
3. Click Create, and the Create SDH Service dialog box is displayed.
4. Set as follows in the dialog box.
− Level: VC12
− Direction: Bidirectional
− Source Slot: 15-N1EFS4-1(SDH-1)
− Source VC4: VC4-4
− Source Timeslot Range(e.g.1,3-6): 1–5
− Sink Slot: 7-N2SL4-1(SDH-1)
− Sink VC4: VC4-3
− Sink Timeslot Range(e.g.1,3-6): 1–5
− Activate Immediately: Yes
− Click Apply.
5. Repeat 4 to set as follows in the dialog box.
− Level: VC3
− Direction: Bidirectional
− Source Slot: 15-N1EFS4-1(SDH-1)
− Source VC4: VC4-1
− Source Timeslot Range(e.g.1,3-6): 1
− Sink Slot: 7-N2SL4-1(SDH-1)
− Sink VC4: VC4-4
− Sink Timeslot Range(e.g.1,3-6): 1
− Activate Immediately: Yes
− Click Apply.
----End

Configuring NE4 Data


The Ethernet service of NE4 to be configured is pass-through service. Follow the steps below
to configure NE4 data.

Step 1 Click the NE switching shortcut icon . Select NE4, and click OK.
Step 2 Select Configuration > SDH Service Configuration from the Function Tree.
Step 3 Click Create, and the Create SDH Service dialog box is displayed.
Step 4 Set as follows in the dialog box.
z Level: VC12
z Direction: Bidirectional
z Source Slot: 12-N2SL16-1(SDH-1)
z Source VC4: VC4-3

3-14 Huawei Technologies Proprietary Issue 01 (2006-09-20)


OptiX OSN 3500/2500/1500
Configuration Guide 3 Configuring Ethernet Services

z Source Timeslot Range(e.g.1,3-6): 1–5


z Sink Slot: 13-N2SL4-1(SDH-1)
z Sink VC4: VC4-3
z Sink Timeslot Range(e.g.1,3-6): 1–5
z Activate Immediately: Yes
z Click Apply.
Step 5 Repeat 4 to set as follows in the dialog box.
z Level: VC3
z Direction: Bidirectional
z Source Slot: 12-N2SL16-1(SDH-1)
z Source VC4: VC4-4
z Source Timeslot Range(e.g.1,3-6): 1
z Sink Slot: 13-N2SL4-1(SDH-1)
z Sink VC4: VC4-4
z Sink Timeslot Range(e.g.1,3-6): 1
z Activate Immediately: Yes
z Click OK.
----End

3.1.4 Configuration Process (by Trail)

Ethernet service can be created by trail or by station. If you purchase the license with trail management
function, you can create Ethernet service by trail; otherwise, you can only create Ethernet service by
station.

Table 3-5 shows the process of creating point-to-point EPL service on the T2000.

Table 3-5 Process of creating point-to-point EPL service (by trail)


Procedure Action Remarks

1 Create a server trail See section 1.4.10 of chapter 1


2 Create a trunk link
3 Create an EPL trail

Create a Trunk Link


Step 1 Select Trail > Trunk Link Creation from the main menu.
Step 2 Set Bandwidth to 5 x VC12 in the pop-up interface.
Step 3 Click Browse. Select the source NE (NE1), and click OK.

Issue 01 (2006-09-20) Huawei Technologies Proprietary 3-15


OptiX OSN 3500/2500/1500
3 Configuring Ethernet Services Configuration Guide

Step 4 Select the N1EFS4 board, then select VCTRUNK port 1 and select
VC4:4-VC12:1–VC4:4-VC12:5 for available timeslot. Click OK.

Step 5 Click Browse. Select the sink NE (NE5). Select the N1EFS4 board, and select N1EFS4, then
select VCTRUNK port 1 and VC4:4-VC12:1–VC4:4-VC12:5 for Available Timeslot. Click
OK.
Step 6 Select the Activate check box, and leave default setting for others.

Step 7 Click Apply to create the trunk link from NE1 to NE5 of user A.

3-16 Huawei Technologies Proprietary Issue 01 (2006-09-20)


OptiX OSN 3500/2500/1500
Configuration Guide 3 Configuring Ethernet Services

Step 8 Repeat 2–7 to create the trunk link from NE1 to NE5 of user B.
----End

Create an EPL Trail


Step 1 Select Trail > Ethernet Trail Creation > EPL Creation from the main menu.
Step 2 Set source parameters in the pop-up interface.
z Port Usage Strategy: Port
z Click Browse and select a proper source line port: NE 1-13-N1EFS4-PORT1.
z Set sink parameters.
z Port Usage Strategy: Port
z Click Browse and select a proper sink line port: NE 5-15-N1EFS4-PORT1.
z Trunk Link Route Strategy: Use Existing Trunk Link.
z Select Trunk_Link-0001 with bandwidth being 5 x VC12.
z Click Next.

Step 3 Set port attributes in the pop-up interface.

Issue 01 (2006-09-20) Huawei Technologies Proprietary 3-17


OptiX OSN 3500/2500/1500
3 Configuring Ethernet Services Configuration Guide

z For PORT1 of NE1:


− TAG: Access
− Enable port: Enable
z Set PORT1 of NE5 similarly.
Step 4 Click Finish.
Step 5 Repeat 1–4 to create EPL service of user B similarly.

----End

3.2 Configuring the PORT Shared EPL Service


3.2.1 Engineering Requirements
The headquarters of company C is located in NE1, with two branches (M&S Department and
Technical Support Department) located in NE5. The headquarters needs to communicate with
two branches. The service of the two branches is required to be isolated completely, each
occupying 10 Mbit/s bandwidth. The Ethernet switch of company C provides 100 Mbit/s
Ethernet electrical interfaces. The Ethernet switch of headquarters supports virtual local area
network (VLAN), but the interconnected equipment of the two branches does not.

3.2.2 Engineering Planning


The engineering design department conducts planning based on the above requirements and
the engineering information described in Chapter 1, and outputs the following engineering
information:
z Networking Diagram
z Board Information of Each NE
z Service Configuration Diagram of Each NE
z Timeslot Allocation Diagram

3-18 Huawei Technologies Proprietary Issue 01 (2006-09-20)


OptiX OSN 3500/2500/1500
Configuration Guide 3 Configuring Ethernet Services

Networking Diagram
Figure 3-6shows the Ethernet service networking and port allocation.

Figure 3-6 Ethernet service networking and port allocation

C (Headquarters)
PORT3
NE1
T2000

PORT1 PORT2 C(1) C(2)

PORT3 PORT4
A B
NE2 NE4 NE5

PORT1 PORT2

NE3

A B
VC-Trunk

Board Information of Each NE


NE1 and NE5 do not require any new board.

Service Configuration Diagram of Each NE


Figure 3-7shows the service configuration diagram of NE1 and NE5.

Figure 3-7 Service configuration diagram

PORT VCTRUNK VCTRUNK PORT

PORT1 PORT1
A A
10M VCTRUNK1 VCTRUNK1 10M
VC4-4:VC12-1~VC12-5 VC4-4:VC12-1~VC12-5
PORT2 PORT2
B B
VCTRUNK2 VCTRUNK2
40M SDH VC4-1:VC-3-1
40M
VC4-1:VC-3-1

PORT3
C1
PORT3 VCTRUNK3 VCTRUNK3 10M
C VC4-4:VC12-6~VC12-10 VC4-4:VC12-6~VC12-10
PORT4
C2
VCTRUNK4 VCTRUNK4
VC4-4:VC12-11~VC12-15 VC4-4:VC12-11~VC12-15
10M

NE1 NE5

Table 3-6 shows the Ethernet service connection table.

Issue 01 (2006-09-20) Huawei Technologies Proprietary 3-19


OptiX OSN 3500/2500/1500
3 Configuring Ethernet Services Configuration Guide

Table 3-6 Ethernet service connection table

Service C
Attribute

Source NE NE1
Source board - port 13-N1EFS4-3
Source Timeslot range VC4-4: VC12-6–VC12-10 VC4-4:
VC12-11–VC12-15
Source VCTRUNK VCTRUNK3 VCTRUNK4
Working mode of source Auto negotiation Auto negotiation
PORT
TAG flag of source PORT Tag aware Tag aware
Source VLAN ID 3 4
Bound bandwidth 5 x VC12 5 x VC12
Sink NE NE5
Sink board - port 15-N1EFS4-3 15-N1EFS4-4
Sink Timeslot range VC4-4: VC12-6–VC12-10 VC4-4:
VC12-11–VC12-15
Sink VCTRUNK VCTRUNK3 VCTRUNK4
Working mode of sink PORT Auto negotiation Auto negotiation
TAG flag of sink PORT Access Access
Sink VLAN ID 3 4

Timeslot Allocation Diagram


The SDH timeslot allocation for Ethernet services is shown in Figure 3-8.

3-20 Huawei Technologies Proprietary Issue 01 (2006-09-20)


OptiX OSN 3500/2500/1500
Configuration Guide 3 Configuring Ethernet Services

Figure 3-8 Timeslot allocation diagram


Ring
Station NE1 NE2 NE3 NE4 NE1
Timeslot 12-SL16-1 7-SL16-1 12-SL16-1 7-SL16-1 12-SL16-1 7-SL16-1 12-SL16-1 7-SL16-1
VC-12: 6-15
VC4-3
13-EFS4: VC4-4

Chain
Station NE4 NE5
Timeslot 13-SL4-1 7-SL4-1
VC-12: 6-15
VC4-3
15-EFS4: VC4-4

Forwared
Add/Drop

3.2.3 Configuration Process(by Station)


Table 3-7 shows the process of configuring the PORT shared Ethernet EPL service on the
T2000.

Table 3-7 Process of PORT shared EPL service configuration


Procedure Description Remarks

1 Creating a board Not required in this section


2 Configuring Ethernet interfaces
3 Configuring bound paths
4 Creating the PORT shared EPL service
5 Configuring CAR Optional
6 Configuring the cross-connect from
Ethernet boards to SDH line boards

The configuration of the PORT shared EPL service is the same as that of the point-to-point EPL service,
except that the Ethernet service configuration on NE1 and interface attributes are different.

Configuring NE1 Data


Step 1 Configuring Ethernet interfaces
1. Right click the NE1 icon in the Main Topology, and select NE Explorer.
2. Select 13-N1EFS4 from the Object Tree and Configuration > Ethernet Interface
Management > Ethernet Interface from the Function Tree. Then, click .
3. Select External Port, and set as follows.

Issue 01 (2006-09-20) Huawei Technologies Proprietary 3-21


OptiX OSN 3500/2500/1500
3 Configuring Ethernet Services Configuration Guide

− Select the Basic Attributes tab. Set the Enabled/Disabled of the PORT3 to Enabled.
Click Apply.
− Select the TAG Attribute tab. Set the TAG of the PORT3 to Tag Aware.
− Other items adopt the default value. Click Apply.
Step 2 Configuring bound paths
1. Select the Bound Path tab from the Internal Port page.
2. Click Configuration, and the Bound Path Configuration dialog box is displayed.
3. To set bound paths for VCTRUNK3, set as follows in the dialog box.
− Configurable Ports: VCTRUNK3
− Level: VC12-xv
− Direction: Bidirectional
− Available Resources: VC4-4
− Select VC12-6 to VC12-10 from the Available Timeslots one by one, and then click
.
4. To set bound paths for VCTRUNK4, set as follows in the dialog box.
− Configurable Ports: VCTRUNK4
− Level: VC12-xv
− Direction: Bidirectional
− Available Resources: VC4-4
− Select VC12-11 to VC12-15 from the Available Timeslots one by one, and then click
.
− Click OK.
Step 3 Creating the PORT shared EPL service
1. Select Configuration > Ethernet Service > Ethernet Line Service from the Function
Tree.
2. Click New and the Create Ethernet Line Service dialog box is displayed.
3. According to Figure 3-7, set as follows to create the service from C to C1.
− Service Type: EPL
− Service Direction: Bidirectional
− Source Port: PORT3
− Source VLAN: 3
− Sink Port: VCTRUNK3
− Sink VLAN: 3
− Click Apply.
4. Repeat 3 to create the service from C to C2. Set as follows in the dialog box.
− Service Type: EPL
− Service Direction: Bidirectional
− Source Port: PORT3
− Source VLAN: 4
− Sink Port: VCTRUNK4
− Sink VLAN: 4

3-22 Huawei Technologies Proprietary Issue 01 (2006-09-20)


OptiX OSN 3500/2500/1500
Configuration Guide 3 Configuring Ethernet Services

− Click OK.
Step 4 Configuring the cross-connect from Ethernet boards to SDH line boards
1. Select NE1 from the Object Tree.
2. Select Configuration > SDH Service Configuration from the Function Tree.
3. Click Create, and the Create SDH Service dialog box is displayed.
4. Set as follows in the dialog box.
− Level: VC12
− Direction: Bidirectional
− Source Slot: 13-N1EFS4-1(SDH-1)
− Source VC4: VC4-4
− Source Timeslot Range(e.g.1,3-6): 6–15
− Sink Slot: 7-N2SL16-1(SDH-1)
− Sink VC4: VC4-3
− Sink Timeslot Range(e.g.1,3-6): 6–15
− Activate Immediately: Yes
− Click OK.

----End

Issue 01 (2006-09-20) Huawei Technologies Proprietary 3-23


OptiX OSN 3500/2500/1500
3 Configuring Ethernet Services Configuration Guide

Configuring NE5 Data

The data configuration of NE5 is performed in the similar way, except that some parameters are
different.

Step 1 Configuring Ethernet interfaces

1. Click the NE switching shortcut icon . Select NE5, and click OK.
2. Select 15-N1EFS4 from the Object Tree and Configuration > Ethernet Interface
Management > Ethernet Interface from the Function Tree, and then click .
3. Select External Port, and set as follows.
− Select the Basic Attributes tab. Set the Enabled/Disabled of the PORT3 and PORT4
to Enabled. Click Apply.
− Select the TAG Attribute tab. Set the TAG of the PORT3 and PORT4 to Access. Set
the Default VLAN ID of the PORT3 to 3. Set the Default VLAN ID of the PORT4
to 4.
− Other items adopt the default value. Click Apply.
Step 2 Configuring bound paths
1. Select the Bound Path tab from the Internal Port page.
2. Click Configuration, and the Bound Path Configuration dialog box is displayed.
3. To set bound paths for VCTRUNK3, set as follows in the dialog box.
− Configurable Ports: VCTRUNK3
− Level: VC12-xv
− Direction: Bidirectional
− Available Resources: VC4-4
− Select VC12-6 to VC12-10 from the Available Timeslots one by one, and then click
.
4. To set bound paths for VCTRUNK4, set as follows in the dialog box.
− Configurable Ports: VCTRUNK4
− Level: VC12-xv
− Direction: Bidirectional
− Available Resources: VC4-4
− Select VC12-11 to VC12-15 from the Available Timeslots one by one, and then click
.
− Click OK.
Step 3 Creating the PORT shared EPL service
1. Select Configuration > Ethernet Service > Ethernet Line Service from the Function
Tree.
2. Click New, and the Create Ethernet Line Service dialog box is displayed.
3. According to Figure 3-7, set as follows to create the service from C1 to C.
− Service Type: EPL
− Service Direction: Bidirectional
− Source Port: PORT3

3-24 Huawei Technologies Proprietary Issue 01 (2006-09-20)


OptiX OSN 3500/2500/1500
Configuration Guide 3 Configuring Ethernet Services

− Source VLAN: 3
− Sink Port: VCTRUNK3
− Sink VLAN: 3
− Click Apply.
4. Repeat 3 to create the service from C2 to C. Set as follows in the dialog box.
− Service Type: EPL
− Service Direction: Bidirectional
− Source Port: PORT4
− Source VLAN: 4
− Sink Port: VCTRUNK4
− Sink VLAN: 4
− Click OK.
Step 4 Configuring the cross-connect from Ethernet boards to SDH line boards
1. Select NE5 from the Object Tree.
2. Select Configuration > SDH Service Configuration from the Function Tree.
3. Click Create, and the Create SDH Service dialog box is displayed.
4. Set as follows in the dialog box.
− Level: VC12
− Direction: Bidirectional
− Source Slot: 15-N1EFS4-1(SDH-1)
− Source VC4: VC4-4
− Source Timeslot Range(e.g.1,3-6): 6-15
− Sink Slot: 7-N2SL4-1(SDH-1)
− Sink VC4: VC4-3
− Sink Timeslot Range(e.g.1,3-6): 6-15
− Activate Immediately: Yes
− Click OK.
----End

Configuring NE4 Data


The Ethernet service of NE4 to be configured is pass-through service. Follow the steps below
to configure NE4 data.

Step 1 Click the NE switching shortcut icon . Select NE4, and click OK.
Step 2 Select Configuration > SDH Service Configuration from the Function Tree.
Step 3 Click Create, and the Create SDH Service dialog box is displayed.
Step 4 Set as follows in the dialog box.
z Level: VC12
z Direction: Bidirectional
z Source Slot: 12-N2SL16-1(SDH-1)

Issue 01 (2006-09-20) Huawei Technologies Proprietary 3-25


OptiX OSN 3500/2500/1500
3 Configuring Ethernet Services Configuration Guide

z Source VC4: VC4-3


z Source Timeslot Range(e.g.1,3-6): 6–15
z Sink Slot: 13-N2SL4-1(SDH-1)
z Sink VC4: VC4-3
z Sink Timeslot Range(e.g.1,3-6): 6–15
z Activate Immediately: Yes
z Click OK.
----End

3.2.4 Configuration Process (by Trail)

Ethernet service can be created by trail or by station. If you purchase the license with trail management
function, you can create Ethernet service by trail; otherwise, you can only create Ethernet service by
station.

Table 3-8 shows main procedures of creating PORT shared EPL service on the T2000.

Table 3-8 Process of creating PORT-shared EPL service (by trail)


Procedure Description Remarks

1 Creating a server trail See section 1.4.10 of Chapter 1


2 Creating a trunk link
3 Creating an EPL trail

Creating a Trunk Link


Follow the steps below to create a trunk link.
Step 1 Select Trail > Trunk Link Creation from the main menu.
Step 2 Set Bandwidth to 5 x VC12 in the interface displayed.
Step 3 Click Browse. Select the source NE (NE1).
Step 4 In the pop-up interface, select the N1EFS4 board, then select VCTRUNK port 3 and select
VC4:4-VC12:6–VC4:4-VC12:10 for available timeslot. Click OK.
Step 5 Click Browse. Select the sink NE (NE5). In the pop-up interface, select N1EFS4, VCTRUNK
port 3 and VC4:4-VC12:6–VC4:4-VC12:10 for available timeslot.
Step 6 Select the Activate check box, and leave the default setting for others.

3-26 Huawei Technologies Proprietary Issue 01 (2006-09-20)


OptiX OSN 3500/2500/1500
Configuration Guide 3 Configuring Ethernet Services

Step 7 Click Apply to create the trunk link from C of NE1 to C1 of NE5.
Step 8 Repeat steps 2–7 to create the trunk link from C of NE1 to C2 of NE5.
----End

Creating an EPL Trail


Follow the steps below to create an EPL trail.
Step 1 Select Trail > Ethernet Trail Creation > EPL Creation from the main menu.
Step 2 Set source parameters in the pop-up interface.
z Port Usage Strategy: Port+VLAN
z Click Browse and select a proper source line port: NE1-13-N1EFS4-PORT3.

Issue 01 (2006-09-20) Huawei Technologies Proprietary 3-27


OptiX OSN 3500/2500/1500
3 Configuring Ethernet Services Configuration Guide

z VLAN ID: 3
z Set sink parameters.
z Port Usage Strategy: Port+VLAN
Step 3 Click Browse and select a proper sink line port: NE5-15-N1EFS4-PORT3
z VLAN ID: 3.
z Trunk Link Route Strategy: Use Existing Trunk Links.
z Select Trunk_Link-0003 with bandwidth being 5 x VC12.
z Click Next.
Step 4 Set port attributes in the pop-up interface.
z For PORT3 of NE1:
z TAG: Tag Aware
z Enable Port: Enable
z For PORT3 of NE5:
z TAG: Access
z Enable Port: Enable
z Select the Activate check box.
z Click Finish.
Step 5 Repeat steps 1–4 to create an EPL trail from C of NE1 to C2 of NE5.

3-28 Huawei Technologies Proprietary Issue 01 (2006-09-20)


OptiX OSN 3500/2500/1500
Configuration Guide 3 Configuring Ethernet Services

----End

3.3 Configuring the VCTRUNK Shared EPL Service


3.3.1 Engineering Requirements
D and D' are users of integrated intelligent communities and located in NE2 and NE3
respectively. They need to communicate with each other. E and E' are users of large
corporations and located in NE2 and NE3 respectively. They also need to communicate with
each other. Services of communities and that of corporations are isolated completely. Because
the traffic peak of community services is at night and that of corporation services is in
daytime, they can share a 300 Mbit/s bandwidth. Their Ethernet equipment provides GE
optical interfaces but does not support VLAN.

Issue 01 (2006-09-20) Huawei Technologies Proprietary 3-29


OptiX OSN 3500/2500/1500
3 Configuring Ethernet Services Configuration Guide

3.3.2 Engineering Planning


The engineering design department conducts planning based on the above requirements and
the engineering information described in Chapter 1, and outputs the following engineering
information.
z Networking Diagram
z Board Information of Each NE
z Service Configuration Diagram of Each NE
z Timeslot Allocation Diagram

Networking Diagram
Figure 3-9 shows the Ethernet service networking and port allocation.

Figure 3-9 Ethernet service networking and port allocation

NE1
T2000

PORT1
D
NE2 B
NE4

E NE5
PORT2
NE3

PORT1 PORT2
VC-Trunk

D’ E’

Board Information of Each NE


Ethernet boards need to be added according to the added service type and traffic volume. NE2
and NE3 are added with one N2EGS2 board respectively. Other NEs remain unchanged.
Figure 3-10 shows the board layout of NE2 and NE3.

3-30 Huawei Technologies Proprietary Issue 01 (2006-09-20)


OptiX OSN 3500/2500/1500
Configuration Guide 3 Configuring Ethernet Services

Figure 3-10 Board layout of NE2 and NE3

S S S S S S S S S S S S S S S S S S S
1 2 2 2 2 2 2 2 2 2 2 3 3 3 3 3 3 3 3
9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7
D75S
D75S

PIU

PIU

AUX
FAN FAN FAN

S S S S S S S S S S S S S S S S S S
1 2 3 4 5 6 7 8 9 1 1 1 1 1 1 1 1 1
0 1 2 3 4 5 6 7 8

N2EGS2
GXCSA

GXCSA

GSCC
GSCC
SL16

SL16
PQ1

Service Configuration Diagram of Each NE


Figure 3-11shows the service configuration of NE2 and NE3.

Figure 3-11 Service configuration diagram

MAC VCTRUNK VCTRUNK MAC

PORT1 PORT1
D D’
300M 300M

PORT2 VCTRUNK1 VCTRUNK1 PORT2


E VC4-1:VC3-1~VC3-3 VC4-1:VC3-1~VC3-3 E’
300M VC4-2:VC3-1~VC3-3 VC4-2:VC3-1~VC3-3 300M
SDH

NE2 NE3

Table 3-9 shows the Ethernet service connection table.

Issue 01 (2006-09-20) Huawei Technologies Proprietary 3-31


OptiX OSN 3500/2500/1500
3 Configuring Ethernet Services Configuration Guide

Table 3-9 Ethernet service connection table

Service D E
Attribute

Source NE NE2
Source board - port 13-N2EGS2-1 13-N2EGS2-2
Source Timeslot range VC4-1: VC3-1 to VC3-3
VC4-2: VC3-1 to VC3-3
Source VCTRUNK VCTRUNK1
Working mode of source PORT 1000M full duplex 1000M full duplex
TAG flag of source PORT Access Access
VLAN ID of source PORT 1 2
Bound bandwidth 6 x VC-3
Sink NE NE3
Sink board - port 13-N2EGS2-1 13-N2EGS2-2
Sink Timeslot range VC4-1: VC3-1 to VC3-3
VC4-2: VC3-1 to VC3-3
Sink VCTRUNK VCTRUNK1
Working mode of sink PORT 1000M full duplex 1000M full duplex
TAG flag of sink PORT Access Access
VLAN ID of sink PORT 1 2

Timeslot Allocation Diagram


Figure 3-12 shows the SDH timeslot allocation.

Figure 3-12 SDH timeslot allocation for Ethernet services


Ring
Station NE1 NE2 NE3 NE4 NE1
Timeslot 12-SL16-1 7-SL16-1 12-SL16-1 7-SL16-1 12-SL16-1 7-SL16-1 12-SL16-1 7-SL16-1
VC-3: 1-3
VC4-3
13-EGS2: VC4-1

VC-3: 1-3
VC4-4
13-EGS2: VC4-2

Forward
Add/Drop

3-32 Huawei Technologies Proprietary Issue 01 (2006-09-20)


OptiX OSN 3500/2500/1500
Configuration Guide 3 Configuring Ethernet Services

3.3.3 Configuration Process(by Station)


Table 3-10 shows the process of configuring the VCTRUNK shared EPL service on the
T2000.

Table 3-10 Process of VCTRUNK shared EPL service configuration


Procedure Description Remarks

1 Creating a board
2 Configuring Ethernet interfaces
3 Configuring bound paths
4 Creating the VCTRUNK shared EPL service
5 Configuring CAR Optional.
6 Configuring the cross-connect from Ethernet
boards to SDH line boards

Creating a Board
Follow the steps below to create a board.
Step 1 In the Main Topology, double click the NE2 icon to open the NE panel.
Step 2 Right click slot 13 according to the board layout of NE1 shown in Figure 3-10, and select
N2EGS2.

Step 3 Make sure the N2EGS2 board is configured in slot 13, and click .
Step 4 Repeat steps 1–3 to create the Ethernet board of NE3. Figure 3-10 shows the board layout of
NE3.
----End

Configuring NE2 Data

See theT2000 online help for the meaning of each parameter during service configuration.

Step 1 Configuring Ethernet interfaces


1. Right click the NE2 icon in the Main Topology, and select NE Explorer.
2. Select 13-N2EGS2 from the Object Tree and Configuration > Ethernet Interface
Management > Ethernet Interface from the Function Tree, and then click .
3. Select External Port, and set as follows. Select the Basic Attributes tab. Set the
Enabled/Disabled of the PORT1 and PORT2 to Enabled. Set the Working mode of the
PORT1 and PORT2 to 1000M Full-Duplex. Click Apply.
4. Select the TAG Attribute tab. Set the TAG of the PORT1 and PORT2 to Access. Set
the Default VLAN ID of the PORT1 to 1. Set the Default VLAN ID of the PORT2 to 2.
Other items adopt the default value. Click Apply.

Issue 01 (2006-09-20) Huawei Technologies Proprietary 3-33


OptiX OSN 3500/2500/1500
3 Configuring Ethernet Services Configuration Guide

Step 2 Configuring bound paths


1. Select the Bound Path tab from the Internal Port page.
2. Click Configuration, and the Bound Path Configuration dialog box is displayed.
3. To set bound paths for VCTRUNK1, set as follows in the dialog box.
− Configurable Ports: VCTRUNK1
− Level: VC3-xv
− Direction: Bidirectional
− Available Resources: VC4-1
− Select VC3-1 to VC3-3 from the Available Timeslots, and then click .
− Available Resources: VC4-2
− Select VC3-1 to VC3-3 from the Available Timeslots, and then click .
− Click OK.

Step 3 Creating the VCTRUNK shared EPL service


1. Select Configuration > Ethernet Service > Ethernet Line Service from the Function
Tree.
2. Click New, and the Create Ethernet Line Service dialog box is displayed.
3. According to Figure 3-11, set as follows to create the service of D.
− Service Type: EPL
− Service Direction: Bidirectional
− Source Port: PORT1
− Source VLAN: 1
− Sink Port: VCTRUNK1
− Sink VLAN: 1
− Click Apply.

3-34 Huawei Technologies Proprietary Issue 01 (2006-09-20)


OptiX OSN 3500/2500/1500
Configuration Guide 3 Configuring Ethernet Services

4. Repeat 3 to create the service of E. Set as follows in the dialog box.


− Service Type: EPL
− Service Direction: Bidirectional
− Source Port: PORT2
− Source VLAN: 2
− Sink Port: VCTRUNK1
− Sink VLAN: 2
− Click OK.
Step 4 Configuring the cross-connect from Ethernet boards to SDH line boards
1. Select NE2 from the Object Tree.
2. Select Configuration > SDH Service Configuration from the Function Tree.
3. Click Create, and the Create SDH Service dialog box is displayed.
4. Set as follows in the dialog box.
− Level: VC3
− Direction: Bidirectional
− Source Slot: 13-N2EGS2-1(SDH-1)

Issue 01 (2006-09-20) Huawei Technologies Proprietary 3-35


OptiX OSN 3500/2500/1500
3 Configuring Ethernet Services Configuration Guide

− Source VC4: VC4-1


− Source Timeslot Range(e.g.1,3-6): 1–3
− Sink Slot: 12-N2SL16-1(SDH-1)
− Sink VC4: VC4-3
− Sink Timeslot Range(e.g.1,3-6): 1–3
− Activate Immediately: Yes
− Click Apply.

5. Repeat 4 to set as follows in the dialog box.


− Level: VC3
− Direction: Bidirectional
− Source Slot: 13-N2EGS2-1(SDH-1)
− Source VC4: VC4-2
− Source Timeslot Range(e.g.1,3-6): 1–3
− Sink Slot: 12-N2SL16-1(SDH-1)
− Sink VC4: VC4-4
− Sink Timeslot Range(e.g.1,3-6): 1–3
− Activate Immediately: Yes
− Click OK.
----End

3-36 Huawei Technologies Proprietary Issue 01 (2006-09-20)


OptiX OSN 3500/2500/1500
Configuration Guide 3 Configuring Ethernet Services

Configuring NE3 Data

The data configuration of NE3 is the same as that of NE2.

Step 1 Configuring Ethernet interfaces

1. Click the NE switching shortcut icon . Select NE3, and click OK.
2. Select 13-N2EGS2 from the Object Tree and Configuration > Ethernet Interface
Management > Ethernet Interface from the Function Tree, and then click .
3. Select External Port, and set as follows.
− Select the Basic Attributes tab. Set the Enabled/Disabled of the PORT1 and PORT2
to Enabled. Set the Working mode of the PORT1 and PORT2 to 1000M
Full-Duplex. Click Apply.
− Select the TAG Attribute tab. Set the TAG of the PORT1 and PORT2 to Access. Set
the Default VLAN ID of the PORT1 to 1. Set the Default VLAN ID of the PORT2
to 2.
− Other items adopt the default value. Click Apply.
Step 2 Configuring bound paths
1. Select the Bound Path tab from the Internal Port page.
2. Click Configuration, and the Bound Path Configuration dialog box is displayed.
3. To set bound paths for VCTRUNK1, set as follows in the dialog box.
− Configurable Ports: VCTRUNK1
− Level: VC3-xv
− Direction: Bidirectional
− Available Resources: VC4-1
− Select VC3-1 to VC3-3 from the Available Timeslots, and then click .
− Available Resources: VC4-2
− Select VC3-1 to VC3-3 from the Available Timeslots, and then click .
− Click OK.
Step 3 Creating the VCTRUNK shared EPL service
1. Select Configuration > Ethernet Service > Ethernet Line Service from the Function
Tree.
2. Click New, and the Create Ethernet Line Service dialog box is displayed.
3. According to Figure 3-11, set as follows to create the EPL service for D.
− Service Type: EPL
− Service Direction: Bidirectional
− Source Port: PORT1
− Source VLAN: 1
− Sink Port: VCTRUNK1
− Sink VLAN: 1
− Click Apply.
4. Repeat 3 to create the EPL service for E. Set as follows in the dialog box.

Issue 01 (2006-09-20) Huawei Technologies Proprietary 3-37


OptiX OSN 3500/2500/1500
3 Configuring Ethernet Services Configuration Guide

− Service Type: EPL


− Service Direction: Bidirectional
− Source Port: PORT2
− Source VLAN: 2
− Sink Port: VCTRUNK1
− Sink VLAN: 2
− Click OK.
Step 4 Configuring the cross-connect from Ethernet boards to SDH line boards
1. Select NE3 from the Object Tree.
2. Select Configuration > SDH Service Configuration from the Function Tree.
3. Click Create, and the Create SDH Service dialog box is displayed.
4. Set as follows in the dialog box.
− Level: VC3
− Direction: Bidirectional
− Source Slot: 13-N2EGS2-1(SDH-1)
− Source VC4: VC4-1
− Source Timeslot Range(e.g.1,3-6): 1–3
− Sink Slot: 7-N2SL16-1(SDH-1)
− Sink VC4: VC4-3
− Sink Timeslot Range(e.g.1,3-6): 1–3
− Activate Immediately: Yes
− Click Apply.
5. Repeat 4 to set as follows in the dialog box.
− Level: VC3
− Direction: Bidirectional
− Source Slot: 13-N2EGS2-1(SDH-1)
− Source VC4: VC4-2
− Source Timeslot Range(e.g.1,3-6): 1–3
− Sink Slot: 7-N2SL16-1(SDH-1)
− Sink VC4: VC4-4
− Sink Timeslot Range(e.g.1,3-6): 1–3
− Activate Immediately: Yes
− Click OK.
----End

3.3.4 Configuration Process (by Trail)

Ethernet service can be created by trail or by station. If you purchase the license with trail management
function, you can create Ethernet service by trail; otherwise, you can only create Ethernet service by
station.

Table 3-11 shows the process of creating VCTRUNK shared EPL service on the T2000.

3-38 Huawei Technologies Proprietary Issue 01 (2006-09-20)


OptiX OSN 3500/2500/1500
Configuration Guide 3 Configuring Ethernet Services

Table 3-11 Process of creating VCTRUNK-shared EPL service (by trail)

Procedure Action Remarks

1 Create a server trail See section 1.4.10 of chapter 1


2 Create a trunk link
3 Create an EPL trail

Create a Trunk Link


Step 1 Select Trail > Trunk Link Creation from the main menu.
Step 2 Set Bandwidth to 6 x VC3 in the pop-up interface.
Step 3 Click Browse. Select the source NE (NE2).
Step 4 In the pop-up interface, select the N2EGS2 board, then select VCTRUNK Port 1, 1 and 2 for
Higher Order and VC4:1-VC3:1–VC4:1-VC3:3 and VC4:2-VC3:1–VC4:2-VC3:3 for
available timeslot. Click OK.

Step 5 Click Browse. Select the sink NE (NE3). In the pop-up interface, select N2EGS2,
VCTRUNK port 1, 1 and 2 for Higher Order, and VC4:1-VC3:1–VC4:1-VC3:3 and
VC4:2-VC3:1–VC4:2-VC3:3 for available timeslot.
Step 6 Select the Activate check box, and leave the default setting for others.

Issue 01 (2006-09-20) Huawei Technologies Proprietary 3-39


OptiX OSN 3500/2500/1500
3 Configuring Ethernet Services Configuration Guide

Step 7 Click Apply to create the trunk link from NE2 to NE3 shared by users D, D', E, and E'.
----End

Create an EPL Trail


Step 1 Select Trail > Ethernet Trail Creation > EPL Creation from the main menu.
Step 2 Set source parameters in the pop-up interface.
z Port Usage Strategy: Port+VLAN
z Click Browse and select a proper source line port: NE2-13-N2EGS2-PORT1.
z VLAN ID: 1
Step 3 Set sink parameters.
z Port Usage Strategy: Port+VLAN
z Click Browse and select a proper source line port: NE3-13-N2EGS2-PORT1.
z VLAN ID: 1.
z Trunk Link Route Strategy: Use Existing Trunk Link.
z Select the trunk link with bandwidth being 6 x VC3.
z Click Next.

3-40 Huawei Technologies Proprietary Issue 01 (2006-09-20)


OptiX OSN 3500/2500/1500
Configuration Guide 3 Configuring Ethernet Services

Step 4 Set port attributes in the pop-up interface.


z For PORT1 of NE2:
− TAG: Access
− Enable Port: Enable
z For PORT1 of NE3:
− TAG: Access
− Enable Port: Enable
z Select the Activate check box.

Step 5 Click Finish to create the EPL trail from D of NE2 to D' of NE3.
Step 6 Repeat steps 1–5 to create an EPL trail from E of NE2 to E' of NE3.
----End

Issue 01 (2006-09-20) Huawei Technologies Proprietary 3-41


OptiX OSN 3500/2500/1500
3 Configuring Ethernet Services Configuration Guide

3.4 Configuring the EPLn Service


3.4.1 Engineering Requirements
Company F has three branches located in NE2, NE3 and NE4 respectively. The information
needs to be shared between the branches, and any two branches can visit each other. The three
branches share a 10 Mbit/s bandwidth dynamically. The Ethernet equipment of company F
provides 100 Mbit/s Ethernet interfaces.

3.4.2 Engineering Planning


The engineering design department conducts planning based on the above requirements and
the engineering information described in Chapter 1, and outputs the following engineering
information.
z Networking Diagram
z Board Information of Each NE
z Service Configuration Diagram of Each NE
z Timeslot Allocation Diagram

Networking Diagram
Figure 3-13 shows the Ethernet service networking and port allocation.

Figure 3-13 Ethernet service networking and port allocation

NE1
T2000
VCTRUNK1 VB

PORT1
VB VCTRUNK1
NE2
PORT1
B
NE4
PORT1 PORT1
NE5
NE3

F1 F3

PORT1 VCTRUNK
VCTRUNK1 VB VCTRUNK2

F2 PORT1

Board Information of Each NE


Ethernet boards need to be added according to the added service type and traffic volume. NE2,
NE3 and NE4 are added with one N2EFS0 board respectively. Other NEs remain unchanged.
Figure 3-14 and Figure 3-15 show the board layout of NE2 and NE3, and NE4 respectively.

3-42 Huawei Technologies Proprietary Issue 01 (2006-09-20)


OptiX OSN 3500/2500/1500
Configuration Guide 3 Configuring Ethernet Services

Figure 3-14 Board layout of NE2 and NE3

S S S S S S S S S S S S S S S S S S S
1 2 2 2 2 2 2 2 2 2 2 3 3 3 3 3 3 3 3
9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7

ETF8
D75S
D75S

AUX
PIU

PIU
FAN FAN FAN

S S S S S S S S S S S S S S S S S S
1 2 3 4 5 6 7 8 9 1 1 1 1 1 1 1 1 1
0 1 2 3 4 5 6 7 8

N2EGS2
N2EFS0
GXCSA
GXCSA

GSCC
GSCC
SL16

SL16
PQ1

Figure 3-15 Board layout of NE4

S S S S S S S S S S S S S S S S S S S
1 2 2 2 2 2 2 2 2 2 2 3 3 3 3 3 3 3 3
9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7
D75S
D75S
D75S
D75S

ETF8
C34S
PIU

PIU

AUX

FAN FAN FAN

S S S S S S S S S S S S S S S S S S
1 2 3 4 5 6 7 8 9 1 1 1 1 1 1 1 1 1
0 1 2 3 4 5 6 7 8
N2EFS0
GXCSA
GXCSA

GSCC
PQ1
PQ1

SL16

SL16

GSCC
SL4
PL3

Service Configuration Diagram of Each NE


Figure 3-16 shows the service configuration of NE2, NE3 and NE4.

Issue 01 (2006-09-20) Huawei Technologies Proprietary 3-43


OptiX OSN 3500/2500/1500
3 Configuring Ethernet Services Configuration Guide

Figure 3-16 Service configuration diagram

VCTRUNK PORT

LP2 LP1 PORT1


F1
PORT VCTRUNK VCTRUNK1 10M

VC4-4:VC12-1~VC12-5
VB1
LP2
PORT1 LP1 VCTRUNK1 NE2
F2 VC4-4:VC12-1~VC12-5
10M LP3

VCTRUNK2 VCTRUNK PORT


VB1 VC4-4:VC12-6~VC12-10

NE3 LP2 LP1 PORT1


F3
VCTRUNK1 10M

SDH VC4-4:VC12-1~VC12-5
VB1
NE4

Table 3-12shows the Ethernet service connection table.

Table 3-12 Ethernet service connection table


Service F
Attribute

Source NE NE3
Source board - port 14-N2EFS0-1
Source Timeslot range VC4-4: VC12-1–VC12-5 VC4-4:
VC12-6–VC12-10
Source VCTRUNK VCTRUNK1 VCTRUNK2
Source VCTRUNK attribute PE PE
Working mode of source PORT Auto negotiation
TAG flag of source PORT Access
VLAN ID of source PORT 11 (Set as the user's demand)
VB VB1
Attached port PORT1, VCTRUNK1, VCTRUNK2
Sink NE NE2 NE4
Sink board - port 14-N2EFS0-1 15-N2EFS0-1
Sink Timeslot range VC4-4: VC12-1–VC12-5 VC4-4: VC12-1–VC12-5
Sink VCTRUNK VCTRUNK1 VCTRUNK1
Sink VCTRUNK attribute PE PE
Working mode of sink PORT Auto negotiation Auto negotiation

3-44 Huawei Technologies Proprietary Issue 01 (2006-09-20)


OptiX OSN 3500/2500/1500
Configuration Guide 3 Configuring Ethernet Services

Service F
Attribute

TAG flag of sink PORT Access Access


VLAN ID of sink PORT 11 11
Virtual bridge (VB) VB1 VB1
Attached port PORT1, VCTRUNK1 PORT1, VCTRUNK1

Table 3-13 shows the forwarding filter table of NE2, NE3 and NE4.

Table 3-13 Forwarding filter table


NE name VB VLAN ID Forwarding port

NE2 VB1 11 PORT1, VCTRUNK1


NE3 VB1 11 PORT1, VCTRUNK1,
VCTRUNK2
NE4 VB1 11 PORT1, VCTRUNK1

Timeslot Allocation Diagram


Figure 3-17 shows the SDH timeslot allocation.

Figure 3-17 SDH timeslot allocation for Ethernet services


Ring
Station NE1 NE2 NE3 NE4 NE1
Timeslot 12-SL16-1 7-SL16-1 12-SL16-1 7-SL16-1 12-SL16-1 7-SL16-1 12-SL16-1 7-SL16-1
VC-12: 1-5 VC-12: 1-5
VC4-5
14-EFS0: VC4-4 15-EFS0: VC4-4

Forward
Add/Drop

3.4.3 Configuration Process(by Station)


Table 3-14 shows the process of configuring the EPLn service on the T2000.

Issue 01 (2006-09-20) Huawei Technologies Proprietary 3-45


OptiX OSN 3500/2500/1500
3 Configuring Ethernet Services Configuration Guide

Table 3-14 Process of EPLn service configuration

Procedure Description Remarks

1 Creating a board
2 Configuring Ethernet interfaces
3 Configuring bound paths
4 Creating the EPLn service
5 Configuring the VLAN forwarding filter table
6 Configuring CAR Optional, see 3.1.3
7 Configuring the cross-connect from Ethernet
boards to SDH line boards

Creating a Board
Step 1 In the Main Topology, double click the NE2 icon to open the NE panel.
Step 2 Right click slot 14 according to Figure 3-14, and then select N2EFS0. Right click slot 31, and
then select ETF8.
Step 3 Make sure the N2EFS0 and ETF8 boards are configured in slots 14 and 31, and then click
Close.
Step 4 Repeat steps 1–3 to create the Ethernet board for NE3 and NE4. Figure 3-14 and Figure 3-15
show the board layout of NE3 and NE4 respectively.
----End

Configuring NE2 Data

See the NM online help for the meaning of each parameter during service configuration.

Step 1 Configuring Ethernet interfaces


1. Right click the NE2 icon in the Main Topology, and select NE Explorer.
2. Select 14-N2EFS0 from the Object Tree and Configuration > Ethernet Interface
Management > Ethernet Interface from the Function Tree, and then click .
3. Select External Port, and set as follows.
− Select the Basic Attributes tab. Set the Enabled/Disabled of the PORT1 to Enabled.
Click Apply.
− Select the TAG Attribute tab. Set the TAG of the PORT1 to Access. Set the Default
VLAN ID of the PORT1 to 11.
− Other items adopt the default value. Click Apply.
Step 2 Configuring bound paths
1. Select the Bound Path tab from the Internal Port page.
2. Click Configuration, and the Bound Path Configuration dialog box is displayed.

3-46 Huawei Technologies Proprietary Issue 01 (2006-09-20)


OptiX OSN 3500/2500/1500
Configuration Guide 3 Configuring Ethernet Services

3. To set bound paths for VCTRUNK1, set as follows in the dialog box.
− Configurable Ports: VCTRUNK1
− Level: VC12-xv
− Direction: Bidirectional
− Available Resources: VC4-4
− Select VC12-1 to VC12-5 from the Available Timeslots, and then click .
− Click OK.

Step 3 Creating the EPLn service


1. Select Configuration > Ethernet Service > Ethernet LAN Service from the Function
Tree.
2. Click New and the Create Ethernet LAN Service dialog box is displayed.
3. Set the VB name to VB1.
4. Click Configure Mounted Port and the VB Mount Port Configuration dialog box is
displayed.
5. Set as follows in the dialog box according to the service configuration diagram of NE2.
Select PORT1 and VCTRUNK1 for Available Mounted Ports, and click . Click
OK.

Issue 01 (2006-09-20) Huawei Technologies Proprietary 3-47


OptiX OSN 3500/2500/1500
3 Configuring Ethernet Services Configuration Guide

6. Click OK in the Create Ethernet LAN Service dialog box.

Step 4 Configuring the VLAN forwarding filter table

3-48 Huawei Technologies Proprietary Issue 01 (2006-09-20)


OptiX OSN 3500/2500/1500
Configuration Guide 3 Configuring Ethernet Services

1. Select Configuration > Ethernet Service > Ethernet LAN Service from the Function
Tree. Select VLAN tab.
2. Click New and the Create VLAN dialog box is displayed.
3. Set as following in the dialog box.
− VB: 1-VB1
− VLAN ID: 11
− Selected forwarding ports: PORT1 and VCTRUNK1
− Click OK.

Step 5 Configuring the cross-connect from Ethernet boards to SDH line boards
1. Select NE2 from the Object Tree.
2. Select Configuration > SDH Service Configuration from the Function Tree.
3. Click Create and the Create SDH Service dialog box is displayed.
4. Set as follows in the dialog box.
− Level: VC12
− Direction: Bidirectional
− Source Slot: 14-N2EFS0-1(SDH-1)
− Source VC4: VC4-4
− Source Timeslot Range(e.g.1,3-6): 1–5
− Sink Slot: 12-N2SL16-1(SDH-1)
− Sink VC4: VC4-5
− Sink Timeslot Range(e.g.1,3-6): 1–5
− Activate Immediately: Yes

Issue 01 (2006-09-20) Huawei Technologies Proprietary 3-49


OptiX OSN 3500/2500/1500
3 Configuring Ethernet Services Configuration Guide

− Click OK.

----End

Configuring NE3 Data

The data configuration of NE3 is performed in the same way as that of NE2, except that some
parameters are different.

Step 1 Configuring Ethernet interfaces

1. Click the NE switching shortcut icon . Select NE3, and click OK.
2. Select 14-N2EFS0 from the Object Tree and Configuration > Ethernet Interface
Management > Ethernet Interface from the Function Tree. Then, click .
3. Select External Port, and set as follows.
− Select the Basic Attributes tab. Set the Enabled/Disabled of the PORT1 to Enabled.
Click Apply.
− Select the TAG Attribute tab. Set the TAG of the PORT1 to Access. Set the Default
VLAN ID of the PORT1 to 11.
− Other items adopt the default value. Click Apply.
Step 2 Configuring bound paths
1. Select the Bound Path tab from the Internal Port page.

3-50 Huawei Technologies Proprietary Issue 01 (2006-09-20)


OptiX OSN 3500/2500/1500
Configuration Guide 3 Configuring Ethernet Services

2. Click Configuration and the Bound Path Configuration dialog box is displayed.
3. To set bound paths for VCTRUNK1, set as follows in the dialog box.
− Configurable Ports: VCTRUNK1
− Level: VC12-xv
− Direction: Bidirectional
− Available Resources: VC4-4
− Select VC12-1 to VC12-5 from the Available Timeslots, and then click .
− Configurable Ports: VCTRUNK2
− Level: VC12-xv
− Direction: Bidirectional
− Available Resources: VC4-4
− Select VC12-6 to VC12-10 from the Available Timeslots, and then click .
− Click OK.
Step 3 Creating the EPLn service
1. Select Configuration > Ethernet Service > Ethernet LAN Service from the Function
Tree.
2. Click New and the Create Ethernet LAN Service dialog box is displayed.
3. Set the VB name to VB1.
4. Click Configure Mounted Port and the VB Mount Port Configuration dialog box is
displayed.
5. Set as follows in the dialog box according to the service configuration diagram of NE2.
Select PORT1, VCTRUNK1 and VCTRUNK2 for Available Mounted Ports, and click
. Click OK.
6. Click OK in the Create Ethernet LAN Service dialog box.
Step 4 Configuring the VLAN Forward Filter Table
1. Select Configuration > Ethernet Service > Ethernet LAN Service from the Function
Tree. Select VLAN tab.
2. Click New and the Create VLAN dialog box is displayed.
3. Set as following in the dialog box.
− VB: 1-VB1
− VLAN ID: 11
− Selected forwarding ports: PORT1, VCTRUNK1 and VCTRUNK2
− Click OK.
Step 5 Configuring the cross-connect from Ethernet boards to SDH line boards
1. Select NE3 from the Object Tree.
2. Select Configuration > SDH Service Configuration from the Function Tree.
3. Click Create and the Create SDH Service dialog box are displayed.
4. Set as follows in the dialog box.
− Level: VC12
− Direction: Bidirectional
− Source Slot: 14-N2EFS0-1(SDH-1)

Issue 01 (2006-09-20) Huawei Technologies Proprietary 3-51


OptiX OSN 3500/2500/1500
3 Configuring Ethernet Services Configuration Guide

− Source VC4: VC4-4


− Source Timeslot Range(e.g.1,3-6): 1–5
− Sink Slot: 7-N2SL16-1(SDH-1)
− Sink VC4: VC4-5
− Sink Timeslot Range(e.g.1,3-6): 1–5
− Activate Immediately: Yes
− Click Apply.
5. Repeat 3–4 to set as follows in the dialog box.
− Level: VC12
− Direction: Bidirectional
− Source Slot: 14-N2EFS0-1(SDH-1)
− Source VC4: VC4-4
− Source Timeslot Range(e.g.1,3-6): 6–10
− Sink Slot: 12-N2SL16-1(SDH-1)
− Sink VC4: VC4-5
− Sink Timeslot Range(e.g.1,3-6): 1–5
− Activate Immediately: Yes
− Click OK.
----End

Configuring NE4 Data

The data configuration of NE4 is performed in the same way as that of NE2.

Step 1 Configuring Ethernet interfaces

1. Click the NE switching shortcut icon . Select NE4, and click OK.
2. Select 15-N2EFS0 from the Object Tree and Configuration > Ethernet Interface
Management > Ethernet Interface from the Function Tree, and then click .
3. Select External Port, and set as follows.
− Select the Basic Attributes tab. Set the Enabled/Disabled of the PORT1 to Enabled.
Click Apply.
− Select the TAG Attribute tab. Set the TAG of the PORT1 to Access. Set the Default
VLAN ID of the PORT1 to 11.
− Other items adopt the default value. Click Apply.
Step 2 Configuring bound paths
1. Select the Bound Path tab from the Internal Port page.
2. Click Configuration and the Bound Path Configuration dialog box are displayed.
3. To set bound paths for VCTRUNK1, set as follows in the dialog box.
− Configurable Ports: VCTRUNK1
− Level: VC12-xv
− Direction: Bidirectional

3-52 Huawei Technologies Proprietary Issue 01 (2006-09-20)


OptiX OSN 3500/2500/1500
Configuration Guide 3 Configuring Ethernet Services

− Available Resources: VC4-4


− Select VC12-1 to VC12-5 from the Available Timeslots, and then click .
− Click OK.
Step 3 Creating the EPLn service
1. Select Configuration > Ethernet Service > Ethernet LAN Service from the Function
Tree.
2. Click New and the Create Ethernet LAN Service dialog box is displayed.
3. Set the VB name to VB1.
4. Click Configure Mounted Port and the VB Mount Port Configuration dialog box is
displayed.
5. Set as follows in the dialog box according to the service configuration diagram of NE2.
Select PORT1 and VCTRUNK1 for Available Mounted Ports, and click . Click
OK.
6. Click OK in the Create Ethernet LAN Service dialog box.
Step 4 Configuring the VLAN forwarding filter table
1. Select Configuration > Ethernet Service > Ethernet LAN Service from the Function
Tree. Select VLAN tab.
2. Click New and the Create VLAN dialog box is displayed.
3. Set as following in the dialog box.
− VB: 1-VB1
− VLAN ID: 11
− Selected forwarding ports: PORT1 and VCTRUNK1
− Click OK.
Step 5 Configuring the cross-connect from Ethernet boards to SDH line boards
1. Select NE4 from the Object Tree.
2. Select Configuration > SDH Service Configuration from the Function Tree.
3. Click Create and the Create SDH Service dialog box is displayed.
4. Set as follows in the dialog box.
− Level: VC12
− Direction: Bidirectional
− Source Slot: 15-N2EFS0-1(SDH-1)
− Source VC4: VC4-4
− Source Timeslot Range(e.g.1,3-6): 1–5
− Sink Slot: 7-N2SL16-1(SDH-1)
− Sink VC4: VC4-5
− Sink Timeslot Range(e.g.1,3-6): 1–5
− Activate Immediately: Yes
− Click OK.
----End

Issue 01 (2006-09-20) Huawei Technologies Proprietary 3-53


OptiX OSN 3500/2500/1500
3 Configuring Ethernet Services Configuration Guide

3.4.4 Configuration Process (by Trail)

Ethernet service can be created by trail or by station. If you purchase the license with trail management
function, you can create Ethernet service by trail; otherwise, you can only create Ethernet service by
station.

Table 3-15 shows the process of creating EPLn service on the T2000.

Table 3-15 Process of creating EPLn service (by trail)


Procedure Action Remarks

1 Create a server trail See section 1.4.10 of chapter 1


2 Create a trunk link
3 Create an EPLn trail

Create a Trunk Link


Step 1 Select Trail > Trunk Link Creation from the main menu.
Step 2 Set Bandwidth to 5 x VC12 in the pop-up interface.
Step 3 Click Browse. Select the source NE (NE3).
Step 4 In the pop-up interface, select the N2EFS0 board, then select VCTRUNK port 1, 4 for Higher
Order, VC4:4-VC12:1–VC4:4-VC12:5 for available timeslot. Click OK.

Step 5 Click Browse. Select the sink NE (NE2). In the pop-up interface, select N2EFS0, then select
VCTRUNK port 1, 4 for Higher Order, and VC4:4-VC12:1–VC4:4-VC12:5 for available
timeslot (lower order).
Step 6 Select the Activate check box, and leave the default setting for others.

3-54 Huawei Technologies Proprietary Issue 01 (2006-09-20)


OptiX OSN 3500/2500/1500
Configuration Guide 3 Configuring Ethernet Services

Step 7 Click Apply to create the trunk link from NE3 to NE2.
Step 8 Create the trunk link from NE3 to NE4 similarly.

----End

Create an EPLn Trail


Step 1 Select Trail > Ethernet Trail Creation > EPLn Creation from the main menu.
Step 2 Set source parameters in the pop-up EPLn creation window. Double click the nodes
(NE2–NE4) to be added into the EPLn. In the pop-up interface, click to select
available ports and then click OK.

Issue 01 (2006-09-20) Huawei Technologies Proprietary 3-55


OptiX OSN 3500/2500/1500
3 Configuring Ethernet Services Configuration Guide

Step 3 Select the trunk link created previously from Trunk Link Route Strategy and click Next.

Step 4 Set port attributes in the port attribute setting window. For PORT1 of NE2, NE3 and NE4:
z TAG: Access
z Port Enable: Enable

3-56 Huawei Technologies Proprietary Issue 01 (2006-09-20)


OptiX OSN 3500/2500/1500
Configuration Guide 3 Configuring Ethernet Services

Step 5 Click Add in the VLAN configuration window, and set the following parameter in the VLAN
Configuration for Ethernet Trail window.
z VLAN ID: 11

z Select the PORT and VCTRUNK, click to select the port, and click OK.

Step 6 Click Next.

Issue 01 (2006-09-20) Huawei Technologies Proprietary 3-57


OptiX OSN 3500/2500/1500
3 Configuring Ethernet Services Configuration Guide

Step 7 Set the name to be EPLn, select the Activate check box and click Finish.

3-58 Huawei Technologies Proprietary Issue 01 (2006-09-20)


OptiX OSN 3500/2500/1500
Configuration Guide 3 Configuring Ethernet Services

----End

Issue 01 (2006-09-20) Huawei Technologies Proprietary 3-59