SPECIFICATION SALINITY INDICATOR INSTRUMENT| ype ; yo=4004 SHIPYARD DAE WOO SHIPYARD SHIP NO, | 5272/73/74/75 use AIR EJECTOR OUTLET TANK CLEANNING HEATER OUTLET FEED WATER PUMP SUCTION LINE VACUUM CONDENSER OUTLET SECIFICATION 1 | SERIAL No. 2 | MEASURING RANGE 0 = 170 PPM 3 | ACCURACY 1) INDICATION + 2.5% OF Scale 2) ALARM ON/OFF DIFFERENCE | + 1.0% OF Scale 4 | WATER TEMP, COMPENSATION RANGE] 5 °C - 130 °C 5 _| SENSOR OPERATING PRESSURE | 10 Kg/Cm* 6 _| ALARM POINT 30 PPM (Adjustable) | 0-30:Green, 50-170:Red 7 _| ALARM SIGNAL COMMON ALARM SIGNAL| C - NO ~ NC 8 | POWER SOURCE ‘AC 220v 60Hz 10 9 | MOUNTING FLUSH 10 | Signal Output for Digital Indicator : 4 - 20mA ( 0 - 25PPM ) (Atomos Condenser Outlet Only ) COMPONENTS. NO. | NAME OF PART TYPE Q’Ty REMARK 1 | Main Unit yo-4004_| 1 | Flush Type 2 _| Salinity Sensor scyo-1 4 3 | Gate Valve GvYO-1 4 10 Kg/Cr? 4 | Junction Box JB-T 3 | Maker Supply 5 | Junction Box py-2xJB_ | 1 [Increased Safety, EXeTS 6 | Zener Barrier mm7esac | 1 7 | Converter (4-20mA) | C-420 1 | For Digital indicator (Botler panel) 8 | Spare Part STIP-A 1 Orawn Check Revised Title SALINITY INDICATOR SPECIFICATION MAY.KIM DWG NO. |) YO-400A-01 160 85 ° ° CONVERTER c—420 5 ° jenn n-n nap nh ASx4 160 %* INPUT : 0 - 25 PPM > OUTPUT : 4 - 20 mA DRAWN | CHECK FINAL | REVISED TITLE CONVERTER ( C-420 ) M.Y.KIM Y.T.OH DWG. NO. YO-400A-10 SPARE PART LIST NO] ARTICLE UNIT/Q‘TY REMARK FIG 1 [INDICATING LED | EA | 3 | RED:-2- GREEN:-1- Oh 2 |FUSE (GLASS) EA | 4 |1A -2- , 3A -2- =o 3 il. c EA 2 | 14011 (4011) 14011 4}l.c EA | 2 | 2902 2902 5 | TRANSISTOR EA | 8 |ct008 (c9014) ar EA | 4 |1 kK OHM EA | 4 | 4.7 OHM 6 | RESISTOR EA 4 | 47 K OHM —CiD— EA | 4 |100 oHM EA 4 1 MEGA OHM 7 | CAPACITOR EA | 4 |100 uF 35V @ 8 |SELECTOR SWITCH] EA | 1 | 4 STAGE = rower 0 He z oT span ! 9¢ o¢ 2 Be ZENER corte [Za] parRier (wIL765AC) | (HAZARDDUS AREAS | yB-T ()sB-1| () DY-2xsB} ()sB-T ' ' AIR FEED WATER TANK CLEAN, © VACUUM EJECTOR PUMP SUCTION HEATER COND. OUTLET UNE OUTLET OUTLET Drawn Check Final Revised Title ELECTRIC CIRCUIT DIAGRAM MY.KIM Y.1.0H DWG. NO. | YO-400A~02 4 (=n 12 1 gl oe g| 8 a] |] 4 hi 245 198 198 7 $ } 380 2 es x 2 s 379 * Panel Cutting Dimension & Fitting Hole * Weight : 11kg NO. DESCRIPTION 1 | PPM INDICATIONG METER (0 - 170 PPM) 2 | SELECTOR SWITCH FOR SENSOR SELECTION ,} ~ #%,: few 3 POWER INDICATING LAMP (Green Colored LED) 4 ALARM RESET PUSH BUTTON 5__| LAMP TEST PUSH BUTTON * NP: NAME PLATE 6 | POWER ON/OFF SWITCH NP1 : SALINITY INDICATOR 7 ALARM INDICATING LAMP (Red Colored LED) (Yo=4004 ) &_| WATER TEMP. COMPENSATING KNOB (5°C - 120°C) NP2 : AIR EJECTOR OUTLET @ | WOUNTNG HOLE (was x8) 3: FEED W. P. SUC. LINE 10 HINDGE 4: TANK CLEAN HEATER OUTLET 1" DOOR LOCKING BOLT + ACCUM COND. OUTLET 12 TERMINAL BLOCK FOR CABLE CONNECTION 13__| PAINT COLOR - 7.5 BG 7/2 14 | Converter (4 - 20mA) DRAWN | CHECK | FINAL | REVISED || TILE DIMENSION OF MAN UNIT W.Y.KIM Y.1.0H pwG. No. | YO-400A-03 Salinity High Alarm Power Source TO. AMS AC 220v 60Hz / Mox. 30 E Levere=1.25 C [NO[NC] ¢ [NO[NC| C [NONC] C [NO[NC AE.O ACO T.C.0 V.C.0 * MAIN UNIT ( YO - 400A ) Le-pPve-1.25, zener | 28} Barrier | ac) a1 (HAZARDDUS AREA) | DY-2xJB| | | <* Sensor Cable : 2m L-opve~1.25 L-peve-1.25 L-ppve-1.25 Indicator () <=* Junction Box 'L]<=* cote valve D UL Dea AIR FEED W. P. TANK CLEAN VACCUM EJECTOR. SUC. LINE HEATER. COND. * Mark : Maker Supply Drawn | Check | Final | Revised Title ELECTR caro (YO—A00A) M.Y.KIM Y.1.0H DWG. NO. YO-550511-400A-1 POWER SOURCE p< 220v 6dHz *MAIN UNIT (ECR) ———" ¥ 2, E ata1a7e2asasasae [ | (sfsis\sisfa{afsls[o{o] [(HAZARD( SOE eS 4-20mAl sj) > To. Boiler Digital Indicator ——> 1. £/R Alarm N Systern DOUS AREA)! US AREA)| (exi) | BAB | py-248! G1 "Junction Box T 1 *Sensor Cable : 2m |] 1 *Sensor & Gate Vahe AIR FEED W. P. TANK CLEAN VACCUM EJECTOR SUC. LINE HEATER. COND. * Mork : Maker Supply Drawn | Check | Final | Revised Title | ELECTRIC CONNECTION DIAGRAM M.Y.KIM Y.1.0H DWG. NO. | YO-400A-05 Nipple Silicon 2 3 ! 3 | i x ° x Gate Valve -_ \ oa g 2 ° 8 g i x 2 rin “| ye S Sensor (SCYO-1) 3 <= 3 abt. 210 * Weight : 3.9Kg Drawn | Check | Final |Revised Title Sie AE eee) M.Y.KIM Y.1.0H DWG. NO.| YO-4004-06 gg 90 | ( -He im NS 3] PACKING RUBBER | 1 5 | CABLE GLAND: Bess [4 [uoawia [2 | cover BRASS 1 ‘| TERMINAL BLOCK 1 [a 1] BODY BRASS 1 NO] NAME_OF PARTS WATERIAL | OTW_[ REMARKS [W0 | NAME OF PARTS [MATERIAL | CTY | REWARKS APPROVED | HIE | UNT syweol_| TILE CHECKED |B. KM | SCALE © 2-WAY JUNCTION BOX DESIGN Y.M.CHA | COLOR OATE Le TP FOR MARINE USE BD K TN im 1 1 (0 WODEL NO. | JBWS-R4BNI WEIGHT | 0.9 Kg A CODE No. [5-40 SHT NO | 66 115 38 a p ; | 60 {| 35 Al Tee noe 7 | Cm Con Ca TO poms [ 1 [a 2k | ME PLE USS 1 TY cone Ost us| 1 [BOT OF COVER muss | 2 1 | oo0r cast puss |_| Wa 1 AME OF PTS a a ware, | OTF | es AeraOeD wT __| Sith __| TITLE INCREASED SAFETY TYPE CHEED sar | JUNCTION. BOX Desc oe a Te (ExeT5) ME 194.831 P 5 FOR MARINE USE ZED DING BLECTRC 00 i ot LID 1-18 a0 CABLE GLAND Ko (15c) 8 8 8 8 NAME PLATE ( ga EARTH. * BOLT ® ® ® © |e 25 210 «a a NON-HZADOUS HAZARDOUS (BLACK COLOR) (BLUE COLOR) * Weight : 2.2 kg DRAWN | CHECK | FINAL | REVISED TLE DIMENSION OF ZENER BARRIER M.Y.KIM Y.1.0H DWG. NO. | YO-400A-09 INSTRUCTION MANUAL FOR SALINITY INDICATOR DAE SUNG ELECTRIC ENGINEERING 1. General Descrition The salinity indicator YO-400A is capable of making measurement of the density of salinity, impurity, chemicals in the distilled water or fresh water. This equipment is so designed that it causes the alarm lamp to light when the density of salinity, impurity, chemicals is over the setting point (30 PPM). Also in the same time common alarm signal can be issued to the monitoring system. When the density of salinity, impurity, chemicals returns to less than setfing point (30 PPM), alarm is automatically released. Salinity sensor must be located at the place that is not influenced or less influenced by chemical. 2. Specification 1) Measuring range 0 - 170 PPM 2) Water temp. compensating range 58°C - 130°C 3) Sensor operating pressure 10 Kg/Cm? 4) Sensor conductivity sensing method 5) Selfing range of alarm 0 - 170 PPM (30 PPM Factory setted) 6) Relay contact rating for common alarm signal 50 va, C-NO-NC (Without Voltage) 7) Power source 220v 6OHz 19 8) Power consumption Max. 30vA 9) Converter(C-420) 4-20mA (0-25PPM) 3. Composition of the Equipment 1) Measuring unit (Main Unit) -1- set 2) Sensor & Gate Valve ~4- set 4, Explanation of PC Board O-——1 5 2 (Normal / Self-Test) |o) ——— 3 io) ——4 jo) ——— 5 PC Board (Front View) 1) Alarm Indicating Lomp (Red LED) Alarm lamp is on when the density of salinity is over the setting value (30 PPM). 2) Normal / Self-Test Changeover Switch Swithching toggle switch to Self-Test position, enables operator fo ascertain 30 PPM of alarm setting value. 3) Adjustment for Self-Test On the Self-Test switch position to ‘Self-Test’, turn adjusting head by small driver to the clockwise, the indicating meter will increase. At 30 PPM, alarm lamp and common alarm signal ore operated. 4) Span Adjustment For use in span adjusting of the measuring uni Clockwise turn will increase the meter ond PPM 5) Alarm Point Adjustment For use of alarm setting value. Clockwise turn will increase the alarm point high. . Method For Adjustment 1) Method for testing the performance With the power source switch on, the power source indicating lamp glows when the measuring instrument is under operation. After ascertaining that the power from the power source is being supplied, set the ‘Normal/Self—Test changeover switch’ on test position, With ‘Adjustment for Self-test’ turning to clockwise or counter-clockwise and thereby ascericin that the alarm lamp glows and that the indicator shows 30 PPM. 2) Method for Setting the Alarm Setting of olarm is accomplished by ‘Alarm point adjustment’. Set the ‘Normal/Self—Test changeover switch’ to self test position. If the indication of PPM meter does not show 30 PPM, turn ‘Adjustment for self-test’ by small driver unfil 30 PPM. Next, turn the ‘Alarm point adjustment’ to clockwise or count~clockwise so that the alarm lamp will just starts lighting. Set the ‘Normal/Self-test changeover switch’ to normal position. 3) Selfing the ‘Temperature compensating knob’ on the front of measuring unit Compensation of conductivity variable with temperature of the distilled water being measured can be done by turing the ‘water temp. compensation knob’ on the front of measuring unit. Set the knob at actual water temperature. 6. Maintenance And Check 1) Cleaning of electrode In order to maintain exact performance of the equipment, remove the sensor at least once 6 months and clean it. @. Remove the sensor from gate valve. b. By use of soft cloths (waste cloth or the like), wipe the dust or scale deposited on the surface of the electrode of the sensor. 2) How to take out sensor a, Loose and pull out @(nut). b. Take out slowly @(sensor) untill 160mm long (Red Mark), and then close Gate valve handle, Water Red Mark iN | Gate valve ON laa }—U-packing Sax 7. Layout of Mainunit inside Dp jp fo jp q ] 3] ) wD) oOo ja pp fo po p fo io jo jo jo ‘—~ Power unit PCB {Alarm PCB for vaccum cond. ‘= Alarm PCB for Tank clean heater. ‘= Alarm PCB for Feed water pump. ‘— Alarm PCB for Air ejector. ® 2) oe « Alarm Indicating Lamp (Red LED) . Normal / Self-Test Changeover Switch 2 3. Adjustment for Self-Test 4, Span Adjuster 5. . Alarm Point Adjuster 8. 4-20mA Signal for Digital Indicator (range: 0-25 PPM) 4-20mA signal with Dc 24V source is provided to operate Digital PPM indicator on boiler panel. Range is 0-25 PPM Sea salt.

You might also like