WEATHERMAKER 50TFF004-014,
50TJ016-028
WEATHERMASTER 50HJ004-028
Single-Package Rooftop Units
Electric Heating/Electric Cooling
3 to 25 Nominal Tons

50HJ004-014
50TFF004-014

50HJ015,017
50TJ016-025

50TJ028

Standard-Efficiency (TFF,TJ) and


High-Efficiency (HJ) electric heating with electric cooling rooftop
units offer:
Pre-painted galvanized steel
cabinet for long life and quality
appearance
Commercial strength base rails with
built-in rigging capability
Convertible design for vertical or
horizontal supply/return (sizes 004014 only)
Non-corrosive, sloped condensate
drain pan, meets ASHRAE 62 (IAQ)
Two-inch return-air filters
A wide assortment of factoryinstalled options available, including
high-static drives that provide
additional performance range
Optional factory-installed COBRA
energy recovery unit (option on
50HJ004-014 units only)
Factory-installed PremierLink
digital communicating controls
Factory-installed optional gear
driven EconoMi$er IV (vertical
return for sizes 004-012 only) for
use with standard rooftop unit controls (includes CO2 sensor control
capability)
Factory-installed optional gear
driven EconoMi$er2 (vertical return
only) for use with PremierLink DDC
controls (includes 4 to 20 mA actuator for demand control ventilation)
Humid-MiZer adaptive dehumidification system (50HJ004-014)
MoistureMi$er dehumidification
package
Heat Options
Electric resistance heat elements
Glycol hydronic coils

Copyright 2004 Carrier Corporation

905

Form 50H,T-7PD

Table of contents
Features/Benefits. . . . . . . . . .
Model Number Nomenclature
ARI Capacity Ratings . . . . . . .
Options and Accessories . . . .

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

Page
. . . . . . . . . . . . . 2-4
. . . . . . . . . . . . . 5-9
. . . . . . . . . . . 10,11
. . . . . . . . . . . 12-21

50TFF
Physical Data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Base Unit Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Accessory Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Selection Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Performance Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Electrical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Typical Wiring Schematics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Typical Piping and Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Guide Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

22,23
24,25
26,27
28,29
30-68
69-80
81-83
. . .84
85-90

50TJ
Physical Data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91,92
Base Unit Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93,94
Accessory Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95-98
Selection Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .99
Performance Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100-119
Electrical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120,121
Typical Wiring Schematics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122-124
Typical Piping and Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .125
Guide Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126-131
50HJ
Physical Data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Base Unit Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Accessory Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Selection Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Performance Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Electrical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Typical Wiring Schematics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Typical Piping and Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Guide Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

132-138
139-146
147-154
155,156
157-221
222-251
252-262
263,264
265-288

Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 289-298
Application Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 299-303
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .304

Features/Benefits
Every compact one-piece
unit arrives fully assembled,
charged, tested, and ready to
run.
Quiet, efficient operation and
dependable performance
Compressors have vibration isolators
for quiet operation. Efficient fan and
motor design permits operation at low
sound levels.

Unit sizes 008-028 offer lower utility


costs through part-load operation using 2 stages of cooling.
Quiet and efficient operation is provided by belt-driven evaporator fans
(standard on all units over 5 tons). The
belt-driven evaporator-fan is equipped
with variable-pitch pulleys which allow
adjustment within the rpm ranges of
the factory-supplied pulleys.
Increased operating efficiency is
achieved through computer-designed
coils featuring staggered internally
enhanced copper tubes. Fins are
ripple-edged for strength, lanced, and
double waved for higher heat transfer.

Durable, dependable
construction
Designed for durability in any climate,
the weather-resistant cabinets are constructed of galvanized steel and bonderized, and all exterior panels are coated
with a prepainted baked enamel finish.
The paint finish is non-chalking, and is
capable of withstanding ASTM (American Society for Testing and Materials)
B117 500-hour Salt Spray Test. All
internal cabinet panels are primed,
permitting longer life and a more attractive appearance for the entire unit.
In addition, all size 004-014 units
are designed with a single, continuous
top piece to eliminate any possible
leaks at seams or gasketing. Totally enclosed condenser-fan motors and permanently lubricated bearings provide
additional unit dependability.

Easy installation and


conversion
All units are shipped in the vertical duct configuration for fit-up to
standard roof curbs. The contractor
can order and install the roof curb early
in the construction stage, before decisions on size requirements are made.
All units feature a base rail design
with forklift slots and rigging holes for
easier maneuvering. Durable packaging protects all units during shipment
and storage.
The units can be easily converted
from a vertical to a horizontal duct configuration by relocating the panels supplied with the unit (sizes 004-014 only).
To convert size 004-014 units
from vertical to horizontal discharge,
simply relocate 2 panels. The same basic unit can be used for a variety of applications and can be quickly modified
at the jobsite.
To convert size 015-028 units from
vertical to horizontal discharge, use the
optional horizontal supply/return
adapter roof curb (50HJ015,017 and
50TJ016-025) or accessory conversion kit (50HJ020-028).
Convenient duct openings in the
unit basepans permit side-by-side or
concentric duct connections (see
Application data section) without requiring internal unit modification.
NOTE: On units using horizontal supply and return, the accessory barometric relief or power exhaust MUST be
installed on the return ductwork.
Thru-the-bottom service connection capability comes standard with
the rooftop unit to allow power and
control wiring to be routed through the
units basepan, thereby minimizing

roof penetrations (to prevent water


leaks). Power and control connections
are made on the same side of the unit
to simplify installation.
The non-corrosive sloped condensate drain pan (size 004-014)
permits either an external horizontal
side condensate drain (outside the roof
curb) or an internal vertical bottom
drain (inside the roof curb). Both
options require an external, fieldsupplied P-trap.
Standard 2-in. throwaway filters
are easily accessed through a removable panel located above the air intake
hood. No tools are required to change
unit filters.
Belt-driven evaporator-fan motors
allow maximum on-site flexibility without changing motors or drives.
Field-installed accessory electric
heaters are available in a wide range
of capacities. An available single-point
wiring kit makes installation simple.
Low voltage wiring connections
are easily made thanks to the large terminal board which is located for quick,
convenient access.
In addition, color-coded wires permit
easy tracing and diagnostics.

Proven compressor reliability


Design techniques feature computerprogrammed balance between compressor, condenser, and evaporator.
Carrier-specified hermetic compressors are equipped with compressor
overcurrent and overtemperature protection to ensure dependability.
All units have Carriers exclusive
Acutrol (004-014) or TXV (thermostatic expansion valve) metering device (015-028) which precisely controls refrigerant flow, preventing
slugging and flood-back, while maintaining optimum unit performance.
Refrigerant filter driers are standard.
Integrated economizers and

outdoor-air dampers

Available as options or accessories,


economizers and manual outdoor-air
dampers introduce outdoor air which
mixes with the conditioned air, improving indoor-air quality and often reducing energy consumption.
During a first stage call for cooling, if
the outdoor-air temperature is below
the economizer control changeover
set point, the mixed-air sensor modulates the economizer outdoor-air
damper open to take advantage of free
cooling provided by the outside air.
When second-stage cooling is called
for, the compressor is energized in
addition to the economizer. If the

outdoor-air temperature is above the


changeover set point, the first stage
of compression is activated and the
economizer damper stays at minimum
position.
Accessory upgrade kits allow for
control by differential dry-bulb temperature (outdoor vs return), outdoor air
enthalpy changeover, or more precise
differential enthalpy control.
Units can be equipped with different
economizer options to meet specific
controls applications. The factoryinstalled or field-installed EconoMi$er
IV and EconoMi$er2 are available. The
EconoMi$er IV is used with the standard rooftop unit controls and includes
an industry standard, stand-alone,
solid-state control. The control can be
used with a CO2 sensor for DCV (demand control ventilation) operation.
For direct digital control (DDC) applications, the EconoMi$er2 can be operated using PremierLink controls or a
third party controller. The EconoMi$er2 includes 4 to 20 mA actuator
capability for demand control ventilation applications.
All economizers incorporate a parallel blade, gear-driven damper system
for efficient air mixing and reliable
control. In addition, the standard
damper actuator includes a spring
return to provide reliable closure on
power loss. The economizers for sizes
004-014 are equipped with up to
100% barometric relief capability for
high outdoor airflow operations. Economizers for unit sizes 004-014 are
available factory installed for vertical return only. Economizers for unit sizes
015-028 are compatible for vertical or
horizontal return. An optional fieldinstalled barometric relief package is
available for 015-028 size units.
In addition, single-stage power
exhaust is available as a field-installed
accessory for EconoMi$er IV to help
maintain proper building pressure.
For units without economizer, yearround ventilation is enhanced by a
manual outdoor-air damper. On size
004-014 units, a 25% or 50% manual
damper is available as a field-installed
accessory. Unit sizes 015-028 are
equipped with a manual 25% damper.

Service options (50HJ004017, 50TFF004-014 and


50TJ016-028 only)
Servicing a rooftop unit has never
been easier with the new factoryinstalled service options for these
rooftop units. These options include
the following:
Hinged access panels are provided
for the filter/indoor-fan motor,
905

compressors, evaporator fan, and


control box areas. Quick access to
major components is accomplished
by simply unlatching and swinging
open the various panels. Each
hinged panel is permanently
mounted to the unit, thereby eliminating the concern of a dropped or
wind-blown panel puncturing delicate roof materials. The 4 extended
access panels are also equipped
with tie back retaining devices to
hold the door in the open position
while servicing the unit.
An external, covered, 115-v Ground
Fault Interrupt (GFI) receptacle is
provided as a convenient power
source for drills, lights, refrigerant
recovery units, or other electrical
service tools. A factory-supplied step
down transformer is connected to
the load side of the unit main
power connection (size 004-014).
For sizes 015-028, connect the outlet to a field-supplied and properly
fused branch circuit power supply.
Slide out motor-drive-blower
reduces service time (only on
50HJ017).
An integral non-fused disconnect
switch within the rooftop unit
reduces installation time, labor and
material costs. Safety is assured by
an interlock which prevents access to
the control box unless the switch is in
the OFF position. In addition, the
externally mounted handle incorporates power lockout capability to further protect service personnel.

Carrier PremierLink controls


add reliability, efficiency, and
simplification (50HJ004-017,
50TFF004-014 and 50TJ016028 only)
The PremierLink direct digital controls
can be ordered as a factory-installed
option or as a field-installed accessory.
Designed and manufactured exclusively
by Carrier, the controls can be used to
actively monitor and control all modes
of operations, as well as monitor the
following diagnostics and features:
unit number, zone temperature, zone
set point, zone humidity set point,
discharge air temperatures, fan status,
stages of heating, stages of cooling,
damper position, outdoor-air temperature, outdoor humidity level, filter status, fire shutdown status, IAQ (indoor
air quality) set point, enthalpy status,
differential enthalpy status, heat/cool
lockout, cfm set point, pre-occupancy
purge, economizer controls and early
morning warm-up.
This controller has a 38.4K baud
communications capability and is
3

Features/Benefits (cont)
compatible with ComfortLink controls, CCN (Carrier Comfort Network) and ComfortVIEW Software.
The Scrolling Marquee and Navigator display are optional tools that can
be used for programming and monitoring the unit for optimal performance.
The addition of the Carrier CO2 sensor
in the conditioned space provides
ASHRAE 62-99 (American Society of
Heating, Refrigeration and Air Conditioning Engineers) compliance and Demand Control Ventilation.
The PremierLink peer-to-peer,
Internet ready communicating control is
designed specifically for Constant Volume (CV) and Variable Volume and
Temperature (VVT) applications. This
comprehensive controls system allows
all Carrier rooftops with a 3-wire communication bus to be daisy chained together on a roof to create a fully functional HVAC (heating, ventilation, and
air conditioning) automation system.

Indoor-air quality begins with


Carrier rooftops
Sloped condensate pans minimize
biological growth in rooftop units in
accordance with ASHRAE Standard
62. Two-inch filters with optional dirty
filter indicator switch provide for
greater particle reduction in the return
air. The face-split evaporator coils
improve the dehumidification capability of standard units, maximize building
humidity control.
Optional proportional reacting
CO2 sensor is available with the
EconoMi$er IV or EconoMi$er2 outdoor air damper option/accessory to
aid the IAQ benefits.

Humidi-MiZer adaptive
dehumidification system
(50HJ004-014)
Carriers Humidi-MiZer adaptive dehumidification system is an all-inclusive
factory-installed option that can be
ordered with any Weathermaster
50HJ004-014 rooftop unit to meet
the demand for providing a flexible
and high performing solution to
accommodate all of these design related issues. This system expands the envelope of operation of Carriers
Weathermaster 50HJ004-014 rooftop
products to provide unprecedented
flexibility to meet year-round comfort
conditions. The Humidi-MiZer adaptive dehumidification system has the
industrys only dual dehumidification
mode setting. The Humidi-MiZer
system includes two new modes of
operation. The Weathermaster
50HJ004-014 rooftop coupled with
the Humidi-MiZer system is capable of
4

operating in normal design cooling


mode, subcooling mode, and hot gas
reheat mode. Normal Design Cooling
mode is when the unit will operate under its normal sequence of operation
by cycling compressors to maintain
comfort conditions. Subcooling mode
will operate to satisfy part load type
conditions when the space requires
combined sensible and a higher proportion of latent load control. Hot Gas
Reheat mode will operate when outdoor temperatures diminish and the
need for latent capacity is required for
sole humidity control. Hot Gas Reheat
mode will provide neutral air for maximum dehumidification operation.

Exclusive MoistureMi$er
dehumidification package
(50HJ015,017 and
50TJ016-028)
The MoistureMi$er dehumidification
package is a result of recent advances
by Carrier in controlling comfort levels.
This factory-installed option significantly improves the dehumidification capability of the rooftop unit and helps control humidity levels in the building.
This option provides increased dehumidification by cooling the hot liquid
refrigerant leaving the condenser coil.
The MoistureMi$er package consists
of a subcooling coil located on the
leaving-air side of the evaporator coil.
The location of this coil in the indoor
airstream enhances the latent capacity
of the 50HJ and TJ units by as much
as 40%. Many buildings suffer from humidity damage or poor indoor air quality due to humid conditions. The improved latent capacity provided by the
MoistureMi$er option reduces the
buildings humidity, eliminating potential property damage and making the
space more comfortable.
The MoistureMi$er option is the
ideal IAQ (indoor-air quality) option for
hot and humid regions. The operation
of the MoistureMi$er package can be
controlled by a field-installed, wall
mounted humidistat or Thermidistat
device. The circuit activates only when
needed (using the accessory humidistat)
as opposed to some dehumidification
systems that operate continuously. The
humidistat can be set for any humidity
level between 20% and 80% relative
humidity.The Thermidistat device can
be set for any humidity level between
50% and 90% relative humidity.

COBRA energy recovery


units (50HJ004-014 only)
Carriers factory-installed optional
COBRA units recover energy from the
building exhaust air and precondition

ventilation air for the rooftop unit


during winter and summer operation.
These units are designed to satisfy the
higher ventilation requirements and
other building codes while minimizing
energy costs.
Factory installation of the 62AQ section provides the benefit of reduced
field-installation time, single point power connections, and the assurance of a
factory test for the complete COBRA
unit. The COBRA energy recovery
section requires less maintenance than
other energy recovery systems and can
be serviced by any qualified refrigeration technician.
The COBRA energy recovery units
utilize Carriers high-efficiency
50HJ004-014 rooftop units and provide 3 to 121/2 tons of cooling capacity with the capability to pre-condition
600 to 3000 cfm of outdoor air.
Indoor-air quality (IAQ) generally
refers to the level of pollutants inside a
building. These pollutants include cigarette smoke, carbon dioxide exhaled by
occupants, radon gas, car exhaust,
paint fumes, and odors.
Concern over increased indoor air
pollutants has been spurred by several
issues: 1) changes in new building
construction methods and retrofit of
older buildings have reduced air
infiltration rates; 2) Synthetic materials
release airborne particles, odors,
and chemicals; and 3) HVAC (heating,
ventilation, and air conditioning)
systems that bring in minimal fresh
air.
In 1989, IAQ concerns caused
ASHRAE to recommend increased
ventilation for all public buildings.
Simply introducing fresh air into a
building, however, is not always
practical or cost effective. Additional
ventilation can overload HVAC
systems and increase energy costs.
Carriers COBRA energy recovery
unit solves this dilemma by providing
increased fresh air while keeping
increased costs to a minimum. In
addition, the COBRA energy recovery
unit helps reduce humidity levels,
which helps to prevent deterioration of
building materials and retards the
growth of mold and mildew.
The COBRA energy recovery unit
provides the best solution to retaining
the energy-conserving benefits of todays tighter building construction
while improving indoor-air quality.

Model number nomenclature


50TFF004-014 (3 TO 121/2 TONS)

50 TFF

006 P M F 6 - 1

50 Packaged Rooftop
Electric Cooling
Units with Accessory
Electric Heat

HA
FIOPs
Packaging
1 Domestic
3 Export

TFF Constant Volume, Standard Efficiency


Nominal Capacity Tons
004 3 Tons
005 4 Tons
006 5 Tons
007 6 Tons
008 7 1/2 Tons
009 8 1/2 Tons
012 10 Tons
014 12 1/2 Tons
Controls and Sensors
- None
N Novar ETM3051 Control*
P PremierLink DDC Control

Al
Cu
DDC
FIOP

LEGEND
Aluminum
Copper
Direct Digital Control
Factory-Installed Option

*Contact factory for availability and application information.


Refer to 50TFF Price Pages or contact your local Carrier representative for FIOP code table.

Voltage
1 575-3-60
3 208/230-1-60
5 208/230-3-60
6 460-3-60
Coil Protection Options (fin/tube)
- Al/Cu Cond & Evap
B Cu/Cu Cond & Evap
C Cu/Cu Cond & Al/Cu Evap
F E-Coat Al/Cu Cond & Al/Cu Evap
G E-Coat Cu/Cu Cond & Al/Cu Evap
V Al/Cu Pre-Coat Cond Fin & Al/Cu
Indoor Motor Options
- Standard Motor & Drive
A Alternate Motor
M High-Static Indoor Motor

Quality Assurance
Certified to ISO 9001:2000

Model number nomenclature (cont)


50TJ016-028 (15 TO 25 TONS)

50 TJ - 024 P - F 6 - 1 YA
50 Packaged Rooftop
Electric Cooling
Units with Accessory
Electric Heat

TJ Constant Volume, Standard Efficiency

Tons Normal Capacity


016 15 Tons
020 18 Tons
024 20 Tons
028 25 Tons

Control/Service Options
- Standard Controls
G Service Option (Non-fused D/C, Cold 115 C.O.,
Hinged Access Panels) with Standard Controls
H Hinged Access Panels with PremierLink Controller
J Hinged Access Panels
P PremierLink DDC Control
X Service Options with PremierLink Controller

Al
Cu
DDC
FIOP

LEGEND
Aluminum
Copper
Direct Digital Controls
Factory-Installed Option

*Refer to 50TJ Price pages or contact your local Carrier


representative for FIOP code table.

FIOP Code*
Packaging
1 Domestic
3 Export
Design Changes
A Gear Driven EconoMi$er
Voltage
1 575-3-60
5 208/230-3-60
6 460-3-60

Coil Protection Options (fin/tube)


- Al/Cu Cond & Evap
B Cu/Cu Cond & Evap
C Cu/Cu Cond & Al/Cu Evap
F E-Coat Al/Cu Condenser
G E-Coat Cu/Cu Condenser
V Black Pre-Costed Condenser Fins
Fan Drive Position (Standard Motor)
- Standard Motor & Drive

Quality Assurance
Certified to ISO 9001:2000

50HJ004-014

Al
Cu
DDC
FIOP
RTU

LEGEND
Aluminum
Copper
Direct Digital Controls
Factory-Installed Option
Rooftop Unit

*Contact factory for availability and applications.


Refer to 50HJ Price Pages or contact your local Carrier
Representative for FIOP code table.

Quality Assurance
Certified to ISO 9001:2000

50HJ004-012 UNITS ARE


ENERGY STAR QUALIFIED

Model number nomenclature (cont)


50HJ015,017

50

HJ - 017 Z - C 6 - - YA

50 Package
Rooftop Units
Electric Cooling/
Optional Electric Heat

HJ Constant Volume, High Efficiency


Nominal Capacity - Tons
015 12 Tons
017 15 Tons

Service/Control Options
- Standard Controls
G Service Option with Six Hinged Access Panels,
Non-Fused Disconnect, and Non-Powered 115-v GFI
Convenience Outlet
J Hinged Access Panels
P PremierLink DDC Control
LEGEND
Al Aluminum
Cu Copper
DDC Direct Digital Controls
GFI Ground Fault Interrupter
*Refer to 50HJ price pages or contact
your local Carrier representative for
FIOP code table.

FIOP (Factory-Installed Options) Code*

Voltage Description
1 575-3-60
5 208/230-3-60
6 460-3-60

Coil Protection Options


- Al/Cu Condenser and Evaporator
B Cu/Cu Condenser and Evaporator
C Cu/Cu Condenser and Al/Cu Evaporator
F E-Coated Al/Cu Condenser and Al/Cu Evaporator
G E-Coated Cu/Cu Condenser and Al/Cu Evaporator
V Al/Cu Pre-coated Condenser Fins

Quality Assurance
Certified to ISO 9001:2000

50HJ020-028
50HJ

024

AA
Factory-Installed Options Code*

50HJ Single Package Rooftop Units,


Electric Cooling, Optional Electric Heat, Constant Volume
Voltage Description
1 575-3-60
5 208/230-3-60
6 460-3-60

Heating Options
No Heat
A Low Electric Heat
B Medium Electric Heat
C High Electric Heat
Nominal Capacity Tons
020 18 Tons
024 20 Tons
028 25 Tons
Service/Control Options
Mechanical Controls
U Mechanical Controls with Return Smoke Detector
V Mechanical Controls with Supply and Return Smoke Detectors

LEGEND
Al
Aluminum
Cu
Copper
FIOP Factory-Installed Option

Coil Protection Options (fin/tube)


Al/Cu Cond & Evap
A Al/Cu Pre-Coat Cond & Al/Cu Evap
B Al/Cu E-Coat Cond & Al/Cu Evap
C Al/Cu E-Coat Cond & Evap
D Cu/Cu Cond & Al/Cu Evap
E Cu/Cu Cond & Evap
F Cu/Cu E-Coat Cond & Al/Cu Evap
G Cu/Cu E-Coat Cond & Cu/Cu Evap
H Cu/Cu E-Coat Cond & Evap
Indoor Motor Options
A Low Range, Vertical Supply/Return
B Mid-Low Range, Vertical Supply/Return
C Mid-High Range, Vertical Supply/Return
D High Range, Vertical Supply/Return
E Low Range, Horizontal Supply/Return
F Mid-Low Range, Horizontal Supply/Return
G Mid-High Range, Horizontal Supply/Return
H High Range, Horizontal Supply/Return
J Low Range, Vertical Supply/Return with Hinged Panels
K Mid-Low Range, Vertical Supply/Return with Hinged Panels
L Mid-Range, Vertical Supply/Return with Hinged Panels
M High Range, Vertical Supply/Return with Hinged Panels
N Low Range, Horizontal Supply/Return with Hinged Panels
P Mid-Low Range, Horizontal Supply/Return with Hinged Panels
Q Mid-High Range, Horizontal Supply/Return with Hinged Panels
R High Range, Horizontal Supply/Return with Hinged Panels

*Refer to 50HJ price pages or contact your local Carrier representative for FIOP code table.

Quality Assurance
Certified to ISO 9001:2000

ARI* capacity ratings


ARI* CAPACITY RATINGS 50TFF004-014
NET COOLING
CAPACITY
(Btuh)
35,000
47,000
57,000
72,000
85,000
98,000
117,000
144,000

UNIT
50TFF

NOMINAL
TONS

004
005
006
007
008
009
012
014

3
4
5
6
71/2
81/2
10
121/2

dry bulb
Energy Efficiency Ratio
Integrated Part-Load Values
Seasonal Energy Efficiency Ratio
wet bulb

TOTAL
kW

SEER

4.0
5.3
6.7
8.0
9.6
10.9
13.0
16.0

9.7
9.7
9.7

LEGEND

db
EER
IPLV
SEER
wb

*Air Conditioning and Refrigeration Institute.


The SEER values shown for sizes 004, 005, and 006 are for units with the
standard direct drive motors; SEER rating for these units with the optional
belt drive motor is 10.0.
**ARI does not require EER ratings for units with capacity below
65,000 Btuh. For these units, the EER ratings at ARI standard conditions
is provided for information only.
The IPLV applies only to 2-stage cooling units.

EER
8.7**
8.8**
8.5**
9.0
8.9
9.0
9.0
9.2

SOUND
RATING
(dB)
81
81
81
81
87
87
88
87

IPLV
N/A
N/A
N/A
N/A
9.4
9.0
9.4
9.2

NOTES:
1. Rated in accordance with ARI Standards 210-94 (004-012) or 360-93.
2. Ratings are net values, reflecting the effects of circulating fan heat.
3. Ratings are based on:
Cooling Standard: 80 F db, 67 F wb indoor entering-air temperature and
95 F db air entering outdoor unit.
IPLV Standard: 80 F db, 67 F wb indoor entering-air temperature and 80
F db outdoor entering-air temperature.

ARI* CAPACITY RATINGS 50TJ016-028

db
EER
IPLV
wb

UNIT
50TM

NOMINAL
TONS

NET COOLING
CAPACITY (Btuh)

TOTAL
WATTS

EER

016
020
024
028

15
18
20
25

178,000
188,000
220,000
270,000

19,813
21,298
25,146
30,901

8.9
8.8
8.7
8.7

LEGEND
Dry Bulb
Energy Efficiency Ratio
Integrated Part-Load Values
Wet Bulb

*Air Conditioning and Refrigeration Institute.


NOTES:
1. Rated in accordance with ARI Standards 360-89 and 270-89.
2. The 50TJ028 is beyond the scope of the ARI Certification Program.
3. ARI ratings are net values, reflecting the effects of circulating fan heat.

10

SOUND
RATING
(decibels)
88
88
94
94

IPLV
9.6
9.8
8.9
9.2

4. Ratings are based on:


Cooling Standard: 80 F db, 67 F wb indoor entering-air temperature
and 95 F db air entering outdoor unit.
IPLV Standard: 80 F db, 67 F wb indoor entering-air temperature and
80 F db outdoor entering-air temperature.

ARI* CAPACITY RATINGS 50HJ004-014


UNIT
50HJ
004
005
006
007
008
009
012
014

NOMINAL
TONS
3
4
5
6
7 1/ 2
8 1/ 2
10
121/2

NET COOLING CAP


(Btuh)
36,000
46,000
61,000
74,000
73,000
104,000
120,000
140,000

TOTAL
kW
3.2
4.1
5.5
6.7
8.2
8.8
10.9
14.3

LEGEND

EER
Energy Efficiency Ratio
IPLV
Integrated Part-Load Value
SEER Seasonal Energy Efficiency Ratio
*Air-Conditioning & Refrigeration Institute.
Applies only to units with capacity of 65,000 Btuh or less.
**ARI does not require EER ratings for units with capacity below
65,000 Btuh. For these units, the EER rating at ARI Standard conditions is
provided for information only.
IPLV is not applicable to single-compressor units.
NOTES:
1. Rated in accordance with ARI Standard 210-94 or 360-93.
2. Ratings are net values, reflecting the effects of circulating fan heat.
Ratings are based on:
Cooling Standard: 80 F db, 67 wb indoor entering-air temperature
and 95 F db outdoor entering-air temperature.

SEER
13.0
13.0
13.0

SOUND RATING
(decibels)
76
76
80
80
82
82
84
86

EER
11.2**
11.1**
11.0**
11.1
11.0
11.8
11.0
9.8

IPLV
N/A
N/A
N/A
N/A
11.6
13.1
11.4
10.5

IPLV Standard: 80 F db, 67 F wb indoor entering-air temperature and


80 F db outdoor entering-air temperature.
3. All 50HJ004-014 units are in compliance with ASHRAE 90.1 2001
Energy Standard for minimum SEER and EER requirements. Refer to
state and local codes or visit the following website: http://solstice.crest.org/efficiency/bcap to determine if compliance with this
standard pertains to a given geographical area of the United States.

ARI* CAPACITY RATINGS 50HJ015,017


UNIT
50HJ
015
017
db
EER
IPLV
wb

NOMINAL
TONS
12
15

NET COOLING
CAPACITY (Btuh)
152,000
176,000

LEGEND
Dry Bulb
Energy Efficiency Ratio
Integrated Part-Load Values
Wet Bulb

TOTAL
WATTS
14,074
16,296

SOUND RATING
(decibels)
8.8
8.8

EER
10.80
10.80

IPLV
11.8
11.7

4. All 50HJ015, 017 units are in compliance with ASHRAE 90.1 2001
Energy Standard for minimum SEER and EER requirements. Refer to
state and local codes or visit the following website: http://solstice.crest.org/efficiency/bcap to determine if compliance with this
standard pertains to a given geographical area of the United States.

*Air Conditioning and Refrigeration Institute.


NOTES:
1. Rated in accordance with ARI Standards 360-93 and 270-95.
2. ARI ratings are net values, reflecting the effects of circulating fan heat.
3. Ratings are based on:
Cooling Standard: 80 F db, 67 F wb indoor entering-air temperature
and 95 F db air entering outdoor unit.
IPLV Standard: 80 F db, 67 F wb indoor entering-air temperature and
80 F db outdoor entering-air temperature.

ARI* CAPACITY RATINGS 50HJ020-028


UNIT
50HJ
020
024
028**
db
EER
IPLV
wb

NOMINAL
TONS
18
20
25

CFM
5,500
6,000
7,500

NET COOLING
CAPACITY (Btuh)
200,000
234,000
278,000

LEGEND
Dry Bulb
Energy Efficiency Ratio
Integrated Part-Load Values
Wet Bulb

TOTAL
kW
18.5
21.7
27.8

EER
10.8
10.8
10.0

SOUND RATING
(dB)
81.7
81.7
84.6

IPLV
12.0
11.9
10.9

3. Ratings are based on:


Cooling Standard: 80 F db, 67 F wb indoor entering-air temperature
and 95 F db air entering outdoor unit.
IPLV Standard: 80 F db, 67 F wb indoor entering-air temperature and
80 F db outdoor entering-air temperature.

*Air Conditioning and Refrigeration Institute.


IPLV values are calculated based on control configuration T.CTL = 2
(2 Stage Y1).
**Size 028 unit is not listed with ARI, but is tested to ARI standards.
NOTES:
1. Rated in accordance with ARI Standards 360-93 and 270-95.
2. ARI ratings are net values, reflecting the effects of circulating fan heat.

11

Options and accessories


50TFF004-014
ITEM
100% Open Two-Position Damper
25% Open Two-Position Damper
Condenser Coil Grille
Condenser Coil Hail Guard Assembly
Convenience Outlet (Load Side)
Copper Fins Indoor and Outdoor Coil
Copper Fins Outdoor Coil
E-Coat Outdoor Coil (Aluminum)
E-Coat Outdoor Coil (Copper)
EconoMi$er IV with Corporate Controls
EconoMi$er2 (for use with PremierLink or Third Party Controls)
EconoMi$er2 Hinged Panel Kit
Electric Heat
Electronic Programmable Thermostat
Energy$Recycler Mounting Kit
Energy$Recycler Supply Air Blower
Energy$Recycler Transformer for 460 v
Energy$Recycler Transformer for 575 v
Energy$Recycler Unit
Enthalpy or Differential Enthalpy Sensor
Fan/Filter Status
High-Static Motor and Drive
Humidistat
Indoor Air Quality (CO2) Sensor
Light Commercial Thermidistat Device
Low Ambient Kit
Manual Outdoor-Air Damper
Motormaster I, II, IV Head Pressure Control
Novar Control
Outdoor Air Enthalpy Sensor
Outdoor Air/Return Air Temperature Sensor
Power Exhaust Transformer for 575 v
Power Exhaust with Barometric Relief
Pre-Coat Aluminum Fins on Outdoor Coil
PremierLink DDC Communicating Control
Return Air Enthalpy Sensor
Return Air Temperature Sensor
Roof Curbs (Vertical and Horizontal Discharge)
Thermostats and Subbases
Thru-the-Bottom Utility Connections
Time Guard II Control Circuit (Compressor Cycle Delay)
Unit-Mounted Non-Fused Disconnect

OPTION*

X
X
X
X
X
X
X

X
X
X
X
X
X
X
X
X
X
X
X

X
X
X
X
X
X
X
X
X
X
X
X
X
X

*Factory-installed.
Field-installed.
NOTES:
1. Refer to unit price pages or contact your local representative for accessory and option package information.
2. Some options may increase product lead times.

12

ACCESSORY
X
X
X
X

905

X
X
X
X
X
X
X

50TJ016-028
ITEM
25% Open Two-Position Damper
Barometric Relief Damper (Not for use with horizontal roof curb)
Condenser Coil Hail Guard Assembly (016-025)
Convenience Outlet (Load Side)
Copper Fins Indoor and Outdoor Coil
Copper Fins Outdoor Coil
E-Coat Outdoor Coil (Aluminum)
E-Coat Outdoor Coil (Copper)
EconoMi$er IV with Corporate Controls
EconoMi$er2 (for use with PremierLink or Third Party Controls)
EconoMi$er2 Hinged Panel Kit
Electric Heat
Electronic Programmable Thermostat
Enthalpy or Differential Enthalpy Sensor
Fan/Filter Status
High-Static Motor and Drive
Hinged Access Panels
Horizontal Adapter Curb (016-025)
Humidistat
Hydronic Glycol Coil
Indoor Air Quality (CO2) Sensor
Light Commercial Thermidistat Device
Low Ambient Kit
Manual Outdoor-Air Damper
MoistureMi$er Dehumidification Package
Motormaster I, V Head Pressure Control
Novar Control
Outdoor Air Enthalpy Sensor
Power Exhaust without Barometric Relief
Pre-Coat Aluminum Fins on Outdoor Coil
PremierLink DDC Communicating Control
Return Air Enthalpy Sensor
Return Air Temperature Sensor
Roof Curbs (Vertical and Horizontal Discharge)
Thermostats and Subbases
Time Guard II Control Circuit (Compressor Cycle Delay)
Unit-Mounted Non-Fused Disconnect
Winter Start Time Delay

OPTION*

X
X
X
X
X
X
X

ACCESSORY
X
X
X

X
X
X
X
X
X
X

X
X
X
X
X
X
X
X
X
X
X
X**
X
X
X
X**

X
X
X
X
X
X

X**
X

*Factory-installed.
Field-installed.
**Available as a DEC special order only.
NOTES:
1. Refer to unit price pages or contact your local representative for accessory and option package information.
2. Some options may increase product lead times.

905

13

Options and accessories (cont)


50HJ004-014
ITEM
100% Open Two-Position Damper
25% Open Two-Position Damper
COBRA Energy Recovery Unit
COBRA Full Perimeter Roof Curb
COBRA Sleeper Rail (for use with Standard Unit Roof Curb)
Condenser Coil Grille
Condenser Coil Hail Guard Assembly
Convenience Outlet (Load Side)
Copper Fins Indoor and Outdoor Coil
Copper Fins Outdoor Coil
E-Coat Outdoor Coil (Aluminum)
E-Coat Outdoor Coil (Copper)
EconoMi$er IV with Corporate Controls
EconoMi$er2 (for use with PremierLink or Third Party Controls)
EconoMi$er2 Hinged Panel Kit
Electric Heat
Electronic Programmable Thermostat
Energy$Recycler Mounting Kit
Energy$Recycler Supply Air Blower
Energy$Recycler Transformer for 460 v
Energy$Recycler Transformer for 575 v
Energy$Recycler Unit
Enthalpy or Differential Enthalpy Sensor
Fan/Filter Status
High-Static Motor and Drive
Hinged Access Panels
Humidistat
Humidi-MiZer Adaptive Dehumidification System
Indoor Air Quality (CO2) Sensor
Light Commercial Thermidistat Device
Low Ambient Kit
Manual Outdoor-Air Damper
Motormaster I, II, IV Head Pressure Control
Novar Control
Outdoor Air Enthalpy Sensor
Outdoor Air/Return Air Temperature Sensor
Power Exhaust Transformer for 575 v
Power Exhaust with Barometric Relief
Pre-Coat Aluminum Fins on Outdoor Coil
PremierLink DDC Communicating Control
Return Air Enthalpy Sensor
Return Air Temperature Sensor
Roof Curbs (Vertical and Horizontal Discharge)
Thermostats and Subbases
Thru-the-Bottom Utility Connections
Time Guard II Control Circuit (Compressor Cycle Delay)
Unit-Mounted Non-Fused Disconnect

OPTION*

X
X
X
X
X
X
X
X
X
X
X
X

X
X
X
X
X
X
X
X
X
X
X
X

X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X

*Factory-installed.
Field-installed.
NOTES:
1. Refer to unit price pages or contact your local representative for accessory and option package information.
2. Some options may increase product lead times.

14

ACCESSORY
X
X

905

X
X
X
X
X
X
X

50HJ015,017
ITEM
25% Open Two-Position Damper
Barometric Relief Damper (Not for use with horizontal roof curb)
Condenser Coil Hail Guard Assembly
Convenience Outlet (Load Side)
Copper Fins Indoor and Outdoor Coil
Copper Fins Outdoor Coil
E-Coat Outdoor Coil (Aluminum)
E-Coat Outdoor Coil (Copper)
EconoMi$er IV with Corporate Controls
EconoMi$er2 (for use with PremierLink or Third Party Controls)
EconoMi$er2 Hinged Panel Kit
Electric Heat
Electronic Programmable Thermostat
Enthalpy or Differential Enthalpy Sensor
Fan/Filter Status
High-Static Motor and Drive
Hinged Access Panels
Horizontal Adapter Curb
Humidistat
Hydronic Glycol Coil
Indoor Air Quality (CO2) Sensor
Light Commercial Thermidistat Device
Low Ambient Kit
Manual Outdoor-Air Damper
MoistureMi$er Dehumidification Package
Motormaster I, V Head Pressure Control
Novar Control
Outdoor Air Enthalpy Sensor
Power Exhaust without Barometric Relief
Pre-Coat Aluminum Fins on Outdoor Coil
PremierLink DDC Communicating Control
Return Air Enthalpy Sensor
Return Air Temperature Sensor
Roof Curbs (Vertical and Horizontal Discharge)
Thermostats and Subbases
Time Guard II Control Circuit (Compressor Cycle Delay)
Unit-Mounted Non-Fused Disconnect
Winter Start Time Delay

OPTION*

X
X
X
X
X
X
X

ACCESSORY
X
X
X

X
X
X
X
X
X
X

X
X
X
X
X
X
X
X
X
X
X
X**
X
X
X
X**

X
X
X
X
X
X

X**
X

*Factory-installed.
Field-installed.
**Available as a DEC special order only.
NOTES:
1. Refer to unit price pages or contact your local representative for accessory and option package information.
2. Some options may increase product lead times.

905

15

Options and accessories (cont)


50HJ020-028
ITEM
EconoMi$er IV
Power Exhaust
Barometric Relief
Hail Guard
Horizontal Kit
CO2 Sensor
Return Smoke Detector
Supply Smoke Detector
Return and Supply Smoke Detector
Non-Fused Disconnect
Non-Powered Convenience Outlet
Relative Enthalpy Sensor
Differential Relative Enthalpy Sensors
Pre-Coat Condenser
E-Coat Condenser
Copper Condenser
Copper Evaporator
E-Coat Copper Evaporator
Low Range Drive
Mid-Low Range Drive
Mid-High Range Drive
High Range Drive
Roof Curb (14 in.)
Roof Curb (24 in.)
Low Electric Heat
High Electric Heat
Medium Electric Heat
Drip Edge
Two-Position Damper
Condensate Overflow Switch
Phase Loss Detection
Manual Damper
Thermostat and Subbase
Hinged Access Panels
Electronic Programmable Thermostat
Outdoor Air Enthalpy Sensor
Return Air Enthalpy Sensor
Return Air Temperature Sensor
Return Air CO2 Sensor
Indoor Air Quality (CO2) Room Sensor

OPTION*
X
X
X
X
X
X
X
X
X
X
X

X
X

X
X
X
X
X
X
X
X
X
X
X
X
X
X
X

X
X
X
X
X
X

X
X
X
X
X
X
X

*Factory-installed.
Field-installed.
NOTES:
1. Refer to unit price pages or contact your local representative for accessory and option package information.
2. Some options may increase product lead times.

16

ACCESSORY
X
X
X
X
X
X
X
X

905

Carrier PremierLink controls are available as a


factory-installed option or as a field-installed accessory.
The controls can be used to actively monitor and control all
modes of operations.
Roof curbs (horizontal and vertical) permit installation and securing of ductwork to curb prior to mounting
unit on the curb. Both 14-in. and 24-in. roof curbs are
available.
EconoMi$er IV is available as a factory-installed option
in vertical supply/return configuration only for unit
sizes 004-014. Vertical or horizontal configuration is available for unit sizes 015-028. (The EconoMi$er IV is available as a field-installed accessory for horizontal and/or vertical supply return configurations.) The EconoMi$er IV is
provided with an industry standard, stand-alone, solid-state
controller that is easy to configure and troubleshoot. The
EconoMi$er IV is compatible with non-DDC applications.
The EconoMi$er IV is equipped with a barometric relief
damper capable of relieving up to 100% return air (for unit
sizes 004-014 only). Dry bulb outdoor-air temperature sensor is provided as standard. The return air sensor, indoor
enthalpy sensor, and outdoor humidity sensor are provided
as field-installed accessories to provide enthalpy control,
differential enthalpy control, and differential dry bulb temperature control.
EconoMi$er2 is available as a factory-installed option
in vertical supply/return configuration only. (The
EconoMi$er2 is available as a field-installed accessory for
horizontal and/or vertical supply return configurations.)
The EconoMi$er2 is provided without a controller for use
with factory-installed PremierLink controls or fieldinstalled third-party controls. The EconoMi$er2 is
equipped with a barometric relief damper capable of relieving up to 100% return air. Dry bulb outdoor-air temperature sensor is provided as standard. The enthalpy, differential temperature (adjustable), and differential enthalpy control are provided as field-installed accessories. The
EconoMi$er2 is capable of control from a 4 to 20 mA signal through optional 4 to 20 mA design without microprocessor control (required for PremierLink or third party
control interface).
Manual outdoor-air damper can be preset to admit up
to 50% outdoor air for year round ventilation.

905

Two-position damper package is available as an accessory. Both 25% or 100% outdoor air dampers are
available.
Head pressure control (Motormaster) package maintains condensing temperature between 90 F and 110 F
at outdoor ambient temperatures down to 20 F by
condenser-fan speed modulation or condenser-fan cycling
and wind baffles.
Electric resistance heaters are UL listed and available
to match heating requirements. Single point kits available
for each heater when required.
Unit-mounted, non-fused disconnect switch provides
unit power shutoff. The switch is accessible from outside
the unit and provides power off lockout capability.
Convenience outlet is factory-installed and internally
mounted with easily accessible 115-v female receptacle.
Compressor cycle delay (Time Guard II) prevents unit
from restarting for minimum of 5 minutes after shutdown.
Thru-the-bottom utility connectors permit electrical
connections to be brought to the unit through the basepan.
Fan/filter status switch provides status of indoor (evaporator) fan (ON/ OFF) or filter (CLEAN/DIRTY).
Energy$Recycler unit recovers energy from building
exhaust air and pre-conditions ventilation air to allow higher ventilation requirements and minimizing energy cost.
Power exhaust accessory will provide system exhaust of
up to 100% of return air (vertical only). The power exhaust
is a field-installed accessory (separate vertical and horizontal design).
Ultraviolet germicidal lamps eliminate odor causing
mold and fungus that may develop in the wet area of the
evaporator section of the unit. The high output, low temperature germicidal lamps are field installed in the evaporator section of the unit, aimed at the evaporator coil and
condensate pan.
Hinged panel option provides hinged access panels for
the filter, compressor, evaporator fan, and control box areas. Filter hinged panels permit tool-less entry for changing filters. Each hinged panel is permanently attached to
the rooftop unit.

17

Options and accessories (cont)


ACCESSORY ENERGY$RECYCLER UNIT (3 TO 121/2 TON UNITS ONLY)
CONDENSER-FAN
DISCHARGE AIR

EXHAUST
AIR

FRESH AIR
INLET
OUTDOOR-AIR
INLET

ROOF CURB
RETURN AIR
BAFFLE
MOUNTING
KIT
OUTDOOR AIRFLOW

FILTER
ACCESS

INDOOR AIRFLOW
SUPPLY AIR
RETURN AIR

GEAR-DRIVEN ECONOMI$ER IV

ECONOMI$ER IV CONTROL
EXH

N1
N

Min
Pos

T1

DCV
2V

SO+
SO

SR

18

24
Vac
HOT

24 Vac
COM

ACTUATOR

Max
10V

DCV

AQ

SR+

WIRING
HARNESS

Open

AQ1

ECONOMI$ER IV
CONTROLLER

TR1

Set
10V

2V
EXH

P1

TR

COMPONENT PARTS

2V

DCV
Set
10V

Free
Cool
B

EF

EF1

905

OUTSIDE AIR
TEMPERATURE SENSOR
LOW AMBIENT
SENSOR

UNIT-MOUNTED DISCONNECT (Sizes 004-014)

UNIT-MOUNTED DISCONNECT (Sizes 015-028)

CONVENIENCE OUTLET

19

Options and accessories (cont)


CONTROL BOX HINGED PANEL OPTION,
50HJ004-007 UNITS SHOWN

COMPRESSOR HINGED PANEL OPTION,


50HJ008-014 UNITS SHOWN

20

CONTROL BOX HINGED PANEL OPTION,


50HJ008-014 UNITS SHOWN

COMPRESSOR HINGED PANEL OPTION,


50HJ004-006 UNITS SHOWN

EVAPORATOR-FAN HINGED PANEL OPTION

FILTER HINGED PANEL OPTION

BAROMETRIC RELIEF OR POWER EXHAUST


(Sizes 015-028 Shown)

21

50TFF

Physical data 50TFF004-007


UNIT SIZE 50TFF
NOMINAL CAPACITY (tons)
OPERATING WEIGHT (lb)
Unit
Al/Al*
Al/Cu*
Cu/Cu*
EconoMi$er IV
Roof Curb
COMPRESSOR
Quantity
No. Cylinders (per circuit)
Oil (oz)
REFRIGERANT TYPE
Operating Charge (lb-oz)
Circuit 1
Circuit 2
CONDENSER COIL
Rows...Fins/in.
Total Face Area (sq ft)
CONDENSER FAN
Nominal Cfm
Quantity...Diameter (in.)
Motor Hp...Rpm
Watts Input (Total)
EVAPORATOR COIL
Expansion Device
Rows...Fins/in.
Total Face Area (sq ft)
EVAPORATOR FAN
Quantity...Size (in.)
Type Drive
Nominal Cfm
Maximum Continuous Bhp
Motor Frame Size
Nominal Rpm High/Low
Fan Rpm Range
Motor Bearing Type
Maximum Allowable Rpm
Motor Pulley Pitch Diameter Min/Max (in.)
Nominal Motor Shaft Diameter (in.)
Fan Pulley Pitch Diameter (in.)
Belt, Quantity...Type...Length (in.)
Pulley Center Line Distance (in.)
Speed Change per Full Turn of
Movable Pulley Flange (rpm)
Movable Pulley Maximum Full Turns
From Closed Position
Factory Setting
Factory Speed Setting (rpm)

004
3

005
4

006
5

007
6

365
370
373
50
115

375
381
387
50
115
Reciprocating
1
2
50

395
402
410
50
115

470
479
490
50
115
Scroll
1
2
54

1
2
50

R-22
4-4

1...17
8.36
3500
1...22.0
4...1100
325

1/

2...15
4.17
Std
Alt
High-Static
Std
Alt
High-Static
Std
Alt
High-Static
Std
Alt
High-Static
Std
Alt
High-Static
Std
Alt
High-Static
Std
Alt
High-Static
Std
Alt
High-Static
Std
Alt
High-Static
Std
Alt
High-Static
Std
Alt
High-Static
Std
Alt
High-Static
Std
Alt
High-Static
Std
Alt
High-Static
Std
Alt
High-Static

Fan Shaft Diameter at Pulley (in.)


HIGH-PRESSURE SWITCH (psig)
Standard Compressor Internal Relief (Differential)
Cutout
Reset (Auto.)
LOSS-OF-CHARGE (LOW-PRESSURE) SWITCH (psig)
Cutout
Reset (Auto.)
FREEZE-PROTECTION THERMOSTAT (F)
Opens
Closes
OUTDOOR-AIR INLET SCREENS
RETURN-AIR FILTERS
Quantity...Size (in.)

1...10 x 10
1...10 x 10
1...10 x 10
Direct
Belt
Belt
1200
.34
1.20
2.40
48
48
56
860/800
1620
1725

760-1000
1075-1455
Ball
2100

1.9/2.9
2.8/3.8
1 /2
1 /2
5 /8

4.5
4.5

1...A...36
1...A...39

10.0-12.4
10.0-12.4

48
65

5
6

3
31/2

856
1233
5 /8

LEGEND
Al Aluminum
Bhp Brake Horsepower
Cu Copper
*Evaporator coil fin material/condenser coil fin material. Contact your local representative for
details about coated fins.
Weight of 14-in. roof curb.
**Single phase/three phase.

22

1
2
50

6-6
6-14

Enhanced Copper Tubes, Aluminum Lanced Fins


2...17
2...17
8.36
10.42
Propeller Type
4000
4000
1...22.0
1...22.0
1/ ...1100
1/ ...1100
4
4
325
325
Enhanced Copper Tubes, Aluminum Double-Wavy Fins
Acutrol Metering Device
2...15
3...15
5.5
5.5
Centrifugal Type
1...10 x 10
1...11 x 10
1...10 x 10
1...10 x 10
1...10 x 10
1...10 x 10
Direct
Direct
Belt
Belt
Belt
Belt
1600
2000
.75
1.20
1.20
1.30/2.40**
2.40
2.90
48
48
48
56
56
56
1075/970
1075/1040
1620
1725
1725
1725

835-1185
900-1300
1075-1455
1300-1685
Ball
Ball
2100
2100

1.9/2.9
2.8/3.8
2.8/3.8
3.4/4.4
1/2
1/2
1/2
5/8
5/8
5/8

4.0
5.5
4.5
4.5

1...A...36
1...A...40
1...A...39
1...A...40

10.0-12.4
14.7-15.5
10.0-12.4
14.7-15.5

70
80
65
60

5
6
6
5

3
3
31/2
31/2

975
1100
1233
1416
5/8
5/8
450 50
428
320

9-0

2...17
10.42
4000
1...22.0
4...1100
325

1/

4...15
5.5
1...10 x 10

1...10 x 10
Belt

Belt
2100
2.40

2.90
56

56

1725
1070-1460

1300-1685
Ball
2100
2.8/3.8

3.4/4.4
5/8

5/8
4.5

4.5
1...A...39

1...A...40
14.7-15.5

14.7-15.5
80

60
5

5
3

31/2
1226

1416
5/8
500 50
428
320

73
22 7
30 5
45 5
Cleanable. Screen size and quantity varies with option selected.
Throwaway
2...16 x 25 x 2

Physical data 50TFF008-014

Type Drive
Nominal Cfm
Maximum Continuous Bhp
Motor Frame Size
Fan Rpm Range
Motor Bearing Type
Maximum Allowable Rpm
Motor Pulley Pitch Diameter Min/Max (in.)
Nominal Motor Shaft Diameter (in.)
Fan Pulley Pitch Diameter (in.)
Belt, Quantity...Type...Length (in.)
Pulley Center Line Distance (in.)
Speed Change per Full Turn of
Movable Pulley Flange (rpm)
Movable Pulley Maximum Full Turns
From Closed Position
Factory Setting
Factory Speed Setting (rpm)

008
71/2

755
766
778
75
143
Reciprocating
2
2
42 ea

009
81/2

012
10

760
915
776
937
787
960
75
75
143
143
Reciprocating
Reciprocating
2
2
2
2
65 ea
54 ea
R-22, Acutrol Metering Device

014
121/2

930
957
980
75
143
Scroll
2
2
54 ea

4-13
4-14

Std
Alt
High-Static
Std
Alt
High-Static
Std
Alt
High-Static
Std
Alt
High-Static
Std
Alt
High-Static
Std
Alt
High-Static
Std
Alt
High-Static
Std
Alt
High-Static
Std
Alt
High-Static
Std
Alt
High-Static

6-14
7- 3
8-10
9- 2
7-13
8- 6
Enhanced Copper Tubes, Aluminum Lanced Fins
1...17
2...17
2...17
2...17
20.50
18.00
20.47
25.00
Propeller Type
6400
6400
7000
7000
2...22
2...22
2...22
2...22
1/ ...1100
1/ ...1100
1/ ...1100
1/ ...1100
4
4
4
4
600
600
600
600
Enhanced Copper Tubes, Aluminum Double-Wavy Fins, Acutrol Metering Device, Face Split
3...15
3...15
3...15
4...15
8.0
8.0
10.0
11.1
Centrifugal Type
1...15 x 15
1...15 x 15
1...15 x 15
1...15 x 15
1...15 x 15

1...15 x 15
1...15 x 15
1...15 x 15
1...15 x 15
1...15 x 15

Belt
Belt
Belt
Belt
Belt

Belt
Belt
Belt
Belt
Belt

3000
3100
4000
5000
2.40
2.40
2.40
3.70
2.40

2.90
5.25
3.70
3.70
5.25

56
56
56
56
56

56
56
56
56
56

590- 840
685- 935
685- 935
860-1080
685- 935

835-1085
830-1130
860-1080
860-1080
830-1130

Ball
Ball
Ball
Ball
2100
2100
2100
2100
2.4/3.4
2.8/3.8
2.8/3.8
4.0/5.0
2.8/3.8

3.4/4.4
3.1/4.1
4.0/5.0
4.0/5.0
2.8/3.8

5/
5/
5/
7/
8
8
8
8
5/
7/
7/

8
8
8
7/
7/
7/

8
8
8
7.0
7.0
7.0
8.0
7.0

7.0
5.9
8.0
8.0
5.8

1...A...49
1...A...49
1...A...49
1...A...52
1...A...49

1...A...49
1...BX...46
1...A...55
1...A...55
1...BX...46

16.75-19.25
16.75-19.25
15.85-17.50
15.85-17.50
15.75-19.25

15.85-17.50
15.85-17.50
15.75-19.25
16.75-19.25
15.85-17.50

Std
Alt
High-Static

50
50
60

50

60

50
50
60

44
50

Std
Alt
High-Static
Std
Alt
High-Static
Std
Alt
High-Static

5
5
5
5
5
5
590
685
860
1

5
5

5
685

860
1

5
5
6
5
5
5
685
835
887
1

5
6

5
5

860
887

Fan Shaft Diameter at Pulley (in.)


HIGH-PRESSURE SWITCH (psig)
Standard Compressor Internal Relief (Differential)
Cutout
Reset (Auto.)
LOW-PRESSURE SWITCH (psig)
Cutout
Reset (Auto.)
FREEZE-PROTECTION THERMOSTAT (F)
Opens
Closes
OUTDOOR-AIR INLET SCREENS
RETURN-AIR FILTERS
Quantity...Size (in.)
LEGEND
Al
Aluminum
Bhp Brake Horsepower
Cu
Copper
*Evaporator coil fin material/condenser coil fin material. Contact your local representative for
details about coated fins.

450 50
428
320

500 50
428
320
73
22 7

30 5
45 5
Cleanable. Screen size and quantity varies with option selected.
Throwaway
4...16 x 20 x 2
4...16 x 20 x 2
4...20 x 20 x 2
4...20 x 20 x 2
Weight of 14-in. roof curb.

NOTES:
1. The 50TFF units have a loss-of-charge switch located in the liquid line.
2. High-static motor not available on size 014 units.

23

50TFF

UNIT SIZE 50TFF


NOMINAL CAPACITY (tons)
OPERATING WEIGHT (lb)
Unit
Al/Al*
Al/Cu*
Cu/Cu*
EconoMi$er IV
Roof Curb
COMPRESSOR
Quantity
No. Cylinders (per circuit)
Oil (oz)
REFRIGERANT TYPE
Operating Charge (lb-oz)
Circuit 1
Circuit 2
CONDENSER COIL
Rows...Fins/in.
Total Face Area (sq ft)
CONDENSER FAN
Nominal Cfm
Quantity...Diameter (in.)
Motor Hp...Rpm
Watts Input (Total)
EVAPORATOR COIL
Rows...Fins/in.
Total Face Area (sq ft)
EVAPORATOR FAN
Quantity...Size (in.)

50TFF

Base unit dimensions 50TFF004-007

24

Base unit dimensions 50TFF008-014

50TFF
25

Accessory dimensions 50TFF004-007


CONNECTOR
PKG. ACCY.
CRBTMPWR001A01
CRBTMPWR002A01
CRBTMPWR003A01

50TFF

CRBTMPWR004A01

1-911 /16
[551]

1-4
[406]

D ALT
DRAIN
HOLE

13/4

[44.5]

GAS
3/
4
[19] NPT
1/2
[12.7] NPT
3/
4
[19] NPT

POWER

CONTROL

ROOF CURB
ACCESSORY

ACCESSORY
PWR

CRRFCURB001A01

3/4

[19] NPT
11/4 [31.7]

3/4

[19] NPT

11/4

[31.7]

1/
2

[12.7]
NPT

1/
2

CRRFCURB002A01

[12.7]
NPT

UNIT SIZE

1-2
[356]
2-0
[610]

50TFF
004-007

NOTES:
1. Roof curb accessory is shipped disassembled.
2. Insulated panels.
3. Dimensions in [ ] are in millimeters.
4. Roof curb: galvanized steel.
5. Attach ductwork to curb (flanges of duct rest on
curb).
6. Service clearance: 4 ft on each side.
7.

Direction of airflow.

8. Connector packages CRBTMPWR001A01 and


002A01 are for thru-the-curb type gas. Packages
CRBTMPWR003A01 and 004A01 are for thruthe-bottom type gas connections.

26

Accessory dimensions 50TFF008-014


CONNECTOR
PKG. ACCY.
CRBTMPWR001A01
CRBTMPWR002A01
CRBTMPWR003A01
CRBTMPWR004A01

2-87/16
[827]

1-1015 /16
[583]

D ALT
DRAIN
HOLE

GAS

13/4
[44.5]

3/
4
[19] NPT
1/2
[12.7] NPT
3/
4
[19] NPT

POWER

CONTROL

ACCESSORY
PWR

1/2

1/2

3/4

[19] NPT
11/4 [31.7]

3/
4

[19] NPT

11/4 [31.7]

[12.7]
NPT

[12.7]
NPT

ROOF CURB
A
ACCESSORY
CRRFCURB003A01 1-2 [356]
CRRFCURB004A01 2-0 [610]

UNIT
SIZE
50TFF
008-014

7.

Direction of airflow.

8. Connector packages CRBTMPWR001A01


and 2A01 are for thru-the-curb gas type.
Packages CRBTMPWR003A01 and 4A01
are for the thru-the-bottom type gas
connections.

27

50TFF

NOTES:
1. Roof curb accessory is shipped disassembled.
2. Insulated panels: 1-in. thick polyurethane
foam, 13/4 lb density.
3. Dimensions in [ ] are in millimeters.
4. Roof curb: 16-gage steel.
5. Attach ductwork to curb (flanges of duct rest
on curb).
6. Service clearance 4 ft on each side.

Selection procedure (50TFF006 example)


Determine cooling and heating loads at design
conditions.
Given:
Required Cooling Capacity (TC) . . . . . .67,000 Btuh
Sensible Heat Capacity (SHC). . . . . . . .46,000 Btuh
Required Heating Capacity . . . . . . . . . .60,000 Btuh
Outdoor Entering-Air Temperature db . . . . . . . .95 F
Outdoor Entering-Air Temperature wb. . . . . . . .75 F
Outdoor-Air Entering Airflow Cfm . . . . . . 450 Cfm
Outdoor-Air Winter Design Temperature . . . . . . 0 F
Indoor-Air Winter Design Temperature . . . . . . .70 F
Air to room including outdoor air . . . . . . 2000 Cfm
External Static Pressure . . . . . Supply 0.60 in. wg
Return 0.2 in. wg
Indoor-Air Temperature db (room air) . . . . . . . .78 F
Indoor-Air Temperature wb (room air) . . . . . . . .65 F
Indoor-Air Exhaust Cfm . . . . . . . . . . . . . . 450 Cfm
Electrical Characteristics (V-Ph-Hz) . . . . . . 230-3-60
Vertical discharge unit with Energy$Recycler unit
required.

II

Determine fan speed and power requirements


at design conditions.
Before entering the Fan Performance tables, calculate
the total static pressure required based on unit component. From the given and the Accessory/FIOP
Static Pressure table of the 50TFF find:
External static pressure supply
0.6 in. wg
External static pressure return
0.2 in. wg
Accessory static None
0.0 in. wg
Total Static
0.8 in. wg
Enter the Fan Performance table for vertical
discharge units of the 50TFF006 at 2000 cfm. The
standard motor will provide 0.92 in. wg ESP at high
speed. Watts is 1144.
NOTE: Convert to Fan Heat using the formula below.
Indoor Fan Heat = watts x 3.413 Btuh/watt
= 1144 x 3.413
= 3904 Btuh

50TFF

III

Select Energy$Recycler unit based on Outdoor


Entering Cfm.
Entering the Energy$Recycler Product Data literature,
see the Cooling Ratings table in the Capacities section. At 450 cfm entering outdoor airflow, choose
Model 62AQ060.
Using 450 cfm outdoor supply airflow, 95 F OD DB,
and 75 F OD WB find performance of the 62AQ060
at these conditions:
Energy$Recycler Gross Cooling
Capacity is
13,000 Btuh
Energy$Recycler Gross Sensible
Capacity is
10,090 Btuh
Compressor power is
1.06 kW
Energy$Recycler Leaving db is
73 F
Energy$Recycler Leaving wb is
66.9 F

IV Using the simplified* method below, calculate


the approximate mixed air temperature for the
rooftop unit evaporator coil.
Using the outdoor-air entering cfm, the room cfm and
the room exhaust airflow with their respective db and
wb temperatures, determine the db and wb entering
the rooftop evaporator coil.

28

a) Estimate the mixed air db to the evaporator coil.


t mix db = ((cfm oa x t oa db) + ((cfm ra cfm exh)
x t ra db)) / ((cfm ao + (cfm ra cfm exh)))
= ((450 cfm x 73.0 F) + ((2000 cfm 450 cfm)
x 78 F)) / ((450 cfm + (2000 cfm 450 cfm)))
Mixed air into the rooftop evaporator coil
= 76.9 F db
b) Estimate the mixed air wb to the evaporator coil.
t mix wb* = ((cfm oa x t oa wb) + ((cfm ra cfm
exh) x tra wb))/ ((cfm oa + (cfm ra cfm exh)))
= ((450 cfm x 66.9 F) + ((2000 cfm 450 cfm)
x 65 F)) / ((450 cfm + (2000 cfm 450 cfm)))
Mixed air temperature into the rooftop evaporator
= 65.40 F wb
*Simplified method of determining wet bulb (wb)
temperature of mixture. This approximation is used
because the wb lines in the area of the psychrometric chart used in the calculation is relatively linear,
providing a close approximation. A more accurate
solution can be found using the E-Cat program.
cfm
db
exh
mix
oa
ra
sa
t
wb

LEGEND
cubic feet per minute of air
dry bulb
Energy$Recycler discharge
mixture of outdoor + return air
outside air leaving Energy$Recycler
return air
supply air at coil (sa = oa + ra exh)
temperature
wet bulb

Determine the cooling load requirement for the


rooftop unit.
Customer load is
67,000 Btuh
Less TC supplied by the
Energy$Recycler
13,000 Btuh
Rooftop cooling load required is
54,000 Btuh
VI Select the rooftop unit based on mixed air
entering conditions and cooling load.
Enter cooling capacity table at outdoor entering temperature 95 F, mixed air entering evaporator at
2000 cfm, 76.9 F db, and 65.4 F wb. Interpolation is
required.
The 50TFF006 will provide a total gross cooling
capacity of 58,250 Btuh, a sensible cooling of
41,330 Btuh, and a kW rating of 5.69.
Because these values were not at 80 F entering db,
they were calculated based on the notes following the
Cooling Capacity tables.
NOTE: Unit ratings are gross capacities and do not
include the effect of evaporator-fan motor heat. To
calculate net capacities see Steps VII and VIII.
VII Select net heating capacity of unit to meet
design condition requirements.
Enter the 62AQ060 Heating rating table at 450 cfm.
At 70 F and 0 F find the heating value for the
Energy$Recycler to be 15.2 MBtuh.
Rooftop fan heat from Step II
3,904 Btuh
Energy$Recycler Heat Capacity
15,200 Btuh
add Energy$Recycler optional
supply fan heat if supplied
0 Btuh
Total Unit heat with Energy$Recycler 19,104 Btuh

Gross Sensible Cooling


Rooftop unit
41,330 Btuh
Energy$Recycler
10,090 Btuh
Total
51,420 Btuh
Less
IFM heat (from Step II)
<3,904> Btuh
Opt. Energy$Recycler Supply
Fan Motor Heat
none
Net Sensible Capacity
47,516 Btuh
IX Determine the operating watts of the unit.
Cooling with Energy$Recycler in operation:
a) Rooftop unit:
Using the 50TFF006 cooling capacity table and
the calculations described in Step VI of this procedure, determine:
compressor watts
5,690 watts
Indoor fan motor from Step II
1,144 watts
Outdoor fan motor from Physical Data table find
1/4 hp
Assume OD motor efficiency is 0.75.
Watts = (746 x hp)/(motor Eff)
= (746 x 1/4)/(0.75)
= 249 watts
Dual circuit units will have two outdoor fans, double
values.

b) Energy$Recycler:
Compressor watts from 62AQ060
Cooling Ratings table
1,060 watts
Optional supply fan from
fan curves
none selected
Exhaust fan operating watts from
62AQ060 Exhaust Fan Performance
Curve at 230-v, 450 cfm,
0.2 in. wg, Static =
110 watts
Total watts for the unit in operation
at design conditions
8,253 watts
Electrical data RLA, FLA, LRA, MCA and
MOCP.
Separate Power Supply:
If the 62AQ is wired for separate power see the Electrical Data table.
Single Power Supply with Unit:
The unit is 230 v-3-60 Hz, so from the 50TFF Electrical Data table, find unit electrical data. For the rooftop
unit the data is MCA = 27.3 amps, MOCP =
35 amps, Min Unit Disconnect Size FLA = 29, and
LRA = 128.
For this example follow the steps outlined in the
Application Data section of the Energy$Recycler
Product Data for single power supply for all rooftop
units except size 014 (230-v) and 62AQ on 460-v
power supply. For other size and voltage conditions
follow corresponding steps also outlined in the
Energy$Recycler Product Data Application data
section.
From the Single Power Supply table (Electrical Data,
Energy$Recycler Product Data) find 230 v, for
62AQ060300, X = 8.1 amps and Y = 9.3 amps.
Add X amps to the MCA and MOCP and add Y
amps to the minimum disconnect size.
50TFF
62AQ
Total

MCA
27.3
8.1
35.4

MOCP
35
8.1
43.1

FLA
29
9.3
38.3

LRA
128
31.7
159.7

(MOCP calculation is 43.1. Round the value down to


40. 40 is greater than the MCA of 35.4, therefore 40
is the correct MOCP.)
The wiring to the unit must be suitable for the MCA
calculated above.
The overcurrent protective device for the combination
load is equal to 40, thus a single disconnect may be
used for BOTH the MAIN UNIT and the 62AQ provided that the wire supplying the 62AQ is sized for a
minimum of 33% of the maximum overcurrent protection device value (i.e., 40 x .33 = 14 Amps). No
further subfusing is required.
In this example a 40-amp disconnect would be used
for the combined load of the 50TFF006 and the
62AQ060 Energy$Recycler unit.

29

50TFF

The required heating capacity is 60,000 Btuh. Determine additional electric heat capacity in kW. Therefore 40,896 Btuh (60,000 Btuh 19,104 Btuh) of
additional heat is required.
Determine additional electric heat in kW.
(40,896/3413 Btuh/kW) = 11.98 kW of additional
heat is required.
Enter Electric Heating Capacities tables on page 68,
for the 50TFF006 at 208/230 v, 3 phase. The
16.0 kW heater at 240 v most closely satisfies the
heating requirement. To calculate kW at 230 v use
the multiplication factors table.
16.0 x 0.92 = 14.72 kW
16.0 x 0.92 x 3413 Btuh/kW = 50,239 Btuh
Total unit net heating capacity is 69,343 (50,239 +
19,104) Btuh. The 50TFF006 unit with accessory
16.0 kW electric heater is sufficient.
VIII Determine net cooling capacity.
Cooling capacities are gross capacities and
do not include indoor (evaporator) or optional
Energy$Recycler supply fan heat.
Determine net cooling capacity using the following
formula:
Net Capacity = (Gross Capacity Rooftop Unit +
Energy$Recycler) (Indoor [evaporator] fan motor
[IFM] Heat + Optional Energy$Recycler Supply Fan
motor heat)
Gross Total Cooling
Rooftop unit
58,250 Btuh
Energy$Recycler
13,000 Btuh
Total
71,250 Btuh
Less
IFM heat (from Step II)
<3,904> Btuh
Opt. Energy$Recycler Supply
Fan Motor Heat
none
Net Total Capacity
67,346 Btuh

Performance data 50TFF


COOLING CAPACITIES
50TFF004 (3 TONS)
Temp (F)
Air Entering
Condenser
(Edb)

50TFF

75

85

95

105

115

TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW

72
42.8
20.0
2.91
40.8
19.4
3.14
38.7
18.6
3.35
36.5
17.8
3.55
34.3
17.0
3.76

50TFF005 (4 TONS)
Air Entering Evaporator Cfm/BF
900/0.11
1200/0.14
1500/0.17
Air Entering Evaporator Ewb (F)
67
62
72
67
62
72
67
62
38.9 35.0 44.8 40.8 37.0 45.8 41.9 38.2
24.5 28.7 21.8 27.5 32.8 23.0 30.0 36.0
2.81 2.70 2.99 2.88 2.78 3.02 2.92 2.82
36.9 33.3 42.5 38.7 35.0 43.6 39.9 36.1
23.7 27.9 21.0 26.8 31.8 22.6 29.7 35.1
3.01 2.90 3.20 3.08 2.97 3.24 3.14 3.02
34.9 31.4 40.4 36.6 33.0 41.4 37.6 34.1
22.9 27.0 20.3 26.0 30.9 22.0 28.8 34.0
3.21 3.09 3.42 3.29 3.16 3.47 3.35 3.22
32.8 29.2 38.1 34.3 30.9 39.0 35.2 32.4
22.1 25.9 19.6 25.2 29.8 21.2 28.0 32.3
3.41 3.27 3.63 3.49 3.35 3.68 3.54 3.43
30.7 26.9 35.7 32.1 28.8 36.5 32.9 30.6
21.3 24.8 19.0 24.4 28.8 20.5 27.1 30.6
3.60 3.45 3.84 3.68 3.54 3.88 3.74 3.64

Temp (F)
Air Entering
Condenser
(Edb)
75

85

95

105

115

TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW

Air Entering Evaporator Cfm/BF


1200/0.12
1600/0.15
2000/0.18
Air Entering Evaporator Ewb (F)
72
67
62
72
67
62
72
67
62
57.9 53.1 48.3 60.4 55.9 51.3 62.2 57.3 52.9
27.2 33.3 39.2 29.4 37.2 44.8 31.4 40.3 49.1
4.07 3.93 3.79 4.17 4.03 3.90 4.24 4.08 3.96
55.7 50.8 45.3 57.7 53.4 48.5 59.4 55.0 50.2
26.4 32.5 37.8 28.4 36.7 43.6 30.5 40.3 47.9
4.40 4.24 4.08 4.47 4.35 4.20 4.54 4.42 4.25
52.9 48.1 42.5 55.2 50.5 45.7 56.7 52.0 47.4
25.5 31.5 36.4 27.6 35.6 42.2 29.7 39.2 46.7
4.70 4.54 4.36 4.78 4.63 4.47 4.87 4.70 4.56
50.1 45.3 39.8 52.3 47.6 42.8 53.6 48.9 44.9
24.4 30.3 35.1 26.7 34.5 40.7 28.8 38.1 44.6
5.00 4.81 4.62 5.10 4.91 4.73 5.17 4.99 4.84
47.3 42.6 37.2 49.3 44.6 40.0 50.5 45.9 42.4
23.4 29.2 33.7 25.9 33.3 39.3 27.8 37.1 42.4
5.30 5.07 4.88 5.42 5.19 4.99 5.48 5.28 5.12
Standard Ratings

50TFF006 (5 TONS)
Temp (F)
Air Entering
Condenser
(Edb)
75

85

95

105

115

TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW

Air Entering Evaporator Cfm/BF


1500/0.07
2000/0.09
2500/0.12
Air Entering Evaporator Ewb (F)
72
67
62
72
67
62
72
67
62
71.0 63.8 55.4 74.5 67.2 59.2 76.5 69.7 62.1
33.9 41.5 47.9 37.4 47.4 55.8 40.6 52.8 61.8
5.04 4.82 4.62 5.20 4.97 4.76 5.29 5.06 4.87
69.2 61.0 54.2 72.9 65.6 57.2 75.2 68.1 61.5
33.4 40.5 47.3 37.0 46.9 54.9 40.1 52.3 61.3
5.50 5.27 5.02 5.66 5.41 5.18 5.75 5.50 5.29
65.5 56.6 50.4 69.4 60.9 53.1 71.2 63.3 57.8
32.1 38.8 45.6 35.8 45.3 52.6 39.1 50.9 57.8
5.88 5.62 5.37 6.01 5.76 5.53 6.12 5.87 5.67
61.9 53.1 47.1 65.4 56.6 50.5 67.1 58.8 54.5
30.8 37.5 44.1 34.5 43.7 50.2 37.9 49.3 54.5
6.25 5.99 5.72 6.38 6.13 5.91 6.50 6.23 6.06
58.2 49.7 43.7 61.4 52.3 47.8 63.0 54.3 51.2
29.5 36.1 42.5 33.2 42.1 47.8 36.7 47.6 51.2
6.63 6.35 6.08 6.75 6.49 6.29 6.88 6.59 6.46

BF
Edb
Ewb
kW
Ldb
Lwb
SHC
TC

Temp (F)
Air Entering
Condenser
(Edb)
75

85

95

105

115

30

TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW

1800/0.06
72
86.6
42.2
5.48
84.1
41.4
6.17
81.6
40.6
6.86
78.4
39.4
7.60
75.1
38.1
8.36

67
80.0
52.3
5.33
77.4
51.3
6.00
74.7
50.3
6.67
71.8
49.2
7.39
68.7
47.9
8.14

62
73.6
62.2
5.21
71.0
61.1
5.85
68.5
60.0
6.49
65.6
58.7
7.20
62.5
57.2
7.93

LEGEND
Bypass Factor
Entering Dry-Bulb
Entering Wet-Bulb
Compressor Motor Power Input
Leaving Dry-Bulb
Leaving Wet-Bulb
Sensible Heat Capacity (1000 Btuh) Gross
Total Capacity (1000 Btuh) Gross

NOTES:
1. Direct interpolation is permissible. Do not extrapolate.
2. The following formulas may be used:
t ldb = t edb

sensible capacity (Btuh)


1.10 x cfm

tlwb = Wet-bulb temperature corresponding to enthalpy of air leaving


evaporator coil (hlwb )
hlwb = hewb

50TFF007 (6 TONS)
Air Entering Evaporator Cfm/BF
2100/0.08
2400/0.09
Air Entering Evaporator Ewb (F)
72
67
62
72
67
62
87.8 80.3 73.2 90.8 84.1 77.2
43.0 53.9 65.5 46.5 59.6 71.6
5.69 5.50 5.32 5.59 5.44 5.29
84.0 77.2 69.5 87.8 81.2 74.5
41.7 53.1 64.0 45.5 58.6 70.3
6.21 6.04 5.83 6.27 6.11 5.94
81.0 73.5 66.3 84.8 78.2 71.8
40.8 51.8 62.8 44.6 57.6 69.1
6.78 6.54 6.33 6.95 6.77 6.59
76.8 69.7 62.5 81.6 74.9 68.9
39.4 50.3 61.1 43.5 56.4 67.4
7.30 7.05 6.80 7.72 7.50 7.31
72.5 65.5 58.7 78.0 71.5 66.1
37.9 48.7 58.7 42.3 55.1 65.5
7.81 7.53 7.27 8.49 8.25 8.06

3000/0.11
72
93.2
50.1
5.66
90.1
49.4
6.35
87.0
48.7
7.03
83.3
47.4
7.77
79.5
46.3
8.55

67
86.6
66.4
5.51
83.5
65.4
6.19
80.4
64.5
6.86
76.9
63.1
7.59
73.3
61.6
8.33

62
79.7
78.7
5.35
77.3
76.7
6.02
74.8
74.7
6.69
72.1
72.0
7.41
69.3
69.2
8.18

total capacity (Btuh)


4.5 x cfm

Where: h ewb = Enthalpy of air entering evaporator coil


3. The SHC is based on 80 F edb temperature of air entering evaporator
coil.
Below 80 F edb, subtract (corr factor x cfm) from SHC.
Above 80 F edb, add (corr factor x cfm) to SHC.

BYPASS
FACTOR
(BF)

79
81

.05
.10
.20
.30

1.04
.98
.87
.76

ENTERING AIR DRY-BULB TEMP (F)


78
77
76
75
under 75
82
83
84
85
over 85
Correction Factor
2.07 3.11 4.14 5.18
1.96 2.94 3.92 4.90
Use formula
1.74 2.62 3.49 4.36
shown below.
1.53 2.29 3.05 3.82

Interpolation is permissible.
Correction Factor = 1.10 x (1 BF) x (edb 80).

COOLING CAPACITIES (cont)


50TFF008 (71/2 TONS)
Temp (F)
Air Entering
Condenser
(Edb)
75

85

105

115

2250/0.07
72
102.8
49.4
7.14
98.2
48.0
7.66
93.8
46.4
8.18
88.4
44.6
8.68
82.8
42.6
9.16

67
94.8
61.8
6.82
90.2
60.2
7.34
85.2
58.2
7.84
79.8
56.2
8.30
73.8
53.8
8.78

62
86.2
73.2
6.50
81.6
71.2
7.00
76.6
68.8
7.48
70.8
66.0
7.98
66.0
63.2
8.42

3750/0.12
72
109.2
58.2
7.46
104.6
56.8
7.98
99.4
55.6
8.50
93.8
54.2
8.98
87.6
52.8
9.48

67
101.6
77.4
7.18
96.8
76.0
7.68
91.2
74.4
8.16
85.4
72.4
8.64
79.4
70.4
9.10

62
93.6
92.2
6.86
89.6
89.4
7.40
85.2
85.2
7.92
80.6
80.6
8.42
76.0
75.8
8.94

BF
Edb
Ewb
kW
Ldb
Lwb
SHC
TC

LEGEND
Bypass Factor
Entering Dry-Bulb
Entering Wet-Bulb
Compressor Motor Power Input
Leaving Dry-Bulb
Leaving Wet-Bulb
Sensible Heat Capacity (1000 Btuh) Gross
Total Capacity (1000 Btuh) Gross

NOTES:
1. Direct interpolation is permissible. Do not extrapolate.
2. The following formulas may be used:
sensible capacity (Btuh)
1.10 x cfm

tldb = tedb

tlwb = Wet-bulb temperature corresponding to enthalpy of air leaving


evaporator coil (hlwb )
total capacity (Btuh)
4.5 x cfm

hlwb = hewb
50TFF009 (81/2 TONS)
Temp (F)
Air Entering
Condenser
(Edb)
75

85

95

105

115

TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW

2550/0.08
72
116.6
71.9
7.77
113.3
54.0
8.46
109.1
52.6
8.90
103.3
50.5
9.74
97.7
48.7
10.33

67
108.4
61.9
7.57
104.2
67.7
8.22
99.3
65.9
8.97
94.0
54.0
9.43
87.9
61.7
9.97

62
99.0
75.9
7.38
94.0
80.4
7.96
87.3
77.4
8.68
81.4
74.5
9.08
75.9
71.9
9.61

72
119.2
75.2
7.86
115.7
56.3
5.54
111.2
55.0
8.99
105.9
53.5
9.85
99.9
51.8
10.46

Air Entering Evaporator Cfm/BF


3000/0.10
3400/0.11
Air Entering Evaporator Ewb (F)
67
62
72
67
62
111.3 101.8 120.1 112.8 103.6
65.1
81.4
80.5
68.0
85.6
10.68
7.44
7.89
6.72
7.51
106.9
97.0
117.2 108.7
98.8
72.5
87.1
58.2
76.4
92.5
8.31
8.04
8.60
8.38
8.12
102.0
91.4
112.5 103.6
93.7
70.9
84.9
57.1
75.1
90.3
9.06
8.79
9.06
9.12
8.86
96.3
84.6
107.4
97.7
87.9
69.1
81.4
55.8
73.1
86.6
9.54
9.21
9.92
9.60
9.29
90.4
78.8
101.3
91.8
82.4
66.9
78.1
54.0
71.2
82.3
10.10
9.75
10.54 10.18
9.88

Where: hewb = Enthalpy of air entering evaporator coil


3. The SHC is based on 80 F edb temperature of air entering evaporator coil.
Below 80 F edb, subtract (corr factor x cfm) from SHC.
Above 80 F edb, add (corr factor x cfm) to SHC.

4250/0.135
72
122.3
32.7
7.97
120.1
62.9
8.72
115.3
62.2
4.76
109.4
60.4
10.03
102.9
58.5
10.61

67
114.8
73.9
7.80
111.0
84.2
8.48
105.8
83.2
9.24
99.9
81.4
9.72
93.8
79.4
10.30

50TFF

95

TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW

Standard Ratings
Air Entering Evaporator Cfm/BF
2800/0.09
3000/0.10
Air Entering Evaporator Ewb (F)
72
67
62
72
67
62
105.8
98.2 90.0
106.4
99.0 90.8
52.6
67.8 81.6
53.6
69.8 84.0
7.28
6.98 6.68
7.32
7.04 6.72
101.8
93.6 85.2
102.6
94.4 86.0
51.6
66.4 79.6
52.8
68.6 82.0
7.82
7.50 7.18
7.86
7.54 7.22
97.0
88.4 80.0
97.6
89.0 81.2
50.2
64.6 77.2
51.4
66.8 79.0
8.36
8.00 7.64
8.40
8.04 7.70
91.0
82.8 74.6
91.6
83.4 76.0
48.2
62.6 74.2
49.4
64.8 75.6
8.80
8.46 8.14
8.86
8.50 8.20
85.2
76.8 69.6
85.6
77.4 71.0
46.4
60.4 69.6
47.8
62.6 71.0
9.30
8.92 8.64
9.34
8.96 8.72

62
106.3
94.4
7.60
101.8
101.0
8.23
107.4
97.3
9.00
92.8
92.8
9.48
88.3
88.2
10.10

BYPASS
FACTOR
(BF)

79
81

.05
.10
.20
.30

1.04
.98
.87
.76

ENTERING AIR DRY-BULB TEMP (F)


78
77
76
75
under 75
82
83
84
85
over 85
Correction Factor
2.07 3.11 4.14 5.18
1.96 2.94 3.92 4.90
Use formula
1.74 2.62 3.49 4.36
shown below.
1.53 2.29 3.05 3.82

Interpolation is permissible.
Correction Factor = 1.10 x (1 BF) x (edb 80).

50TFF012 (10 TONS)


Temp (F)
Air Entering
Condenser
(Edb)
75

85

95

105

115

3000/0.095
72
135.8
66.8
9.76
130.0
64.3
10.41
124.1
62.2
11.13
118.1
60.4
11.93
115.0
59.4
12.26

TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW

67
124.8
82.6
9.41
119.6
80.5
10.07
113.7
78.4
10.78
104.6
74.9
11.52
98.0
72.4
11.82

Air Entering Evaporator Cfm/BF


4000/0.125
Air Entering Evaporator Ewb (F)
62
72
67
62
72
112.0
142.4
130.6
119.8
146.5
97.4
73.2
93.4
112.7
79.7
9.10
10.00
9.61
9.27
10.17
104.0
136.0
125.0
114.5
140.0
93.8
71.1
91.7
110.2
77.5
9.74
10.67
10.28
9.94
10.84
96.7
129.5
118.9
106.9
132.8
89.8
105.9
74.9
90.0
69.1
10.40
11.38
10.99
10.63
11.52
87.9
122.7
111.8
98.5
126.0
85.2
66.9
87.7
98.5
73.1
11.10
12.13
11.74
11.41
12.27
84.2
120.0
103.8
93.4
122.6
83.4
66.4
84.8
93.4
72.8
11.40
12.48
12.06
11.78
12.60

5000/0.15
67
134.2
104.4
9.75
127.9
101.8
10.41
122.0
100.1
11.14
115.1
98.3
11.89
109.8
96.6
12.20

62
123.7
123.1
9.41
118.8
118.7
10.09
114.1
114.0
10.83
108.0
108.0
11.65
102.8
102.8
12.00

50TFF014 (121/2 TONS)


Temp (F
Air Entering
Condenser
(Edb)
75

85

95

105

115

TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW

3750/0.08
72
175.6
85.7
11.16
169.3
83.9
12.15
161.9
81.4
13.12
154.9
79.0
14.16
146.2
76.1
15.09

67
162.2
107.3
10.85
155.7
104.8
11.78
148.9
102.0
12.72
141.3
99.2
13.66
132.2
95.7
14.57

62
149.2
128.0
10.57
140.6
124.0
11.42
132.0
119.8
12.28
123.0
115.5
13.17
113.1
110.3
14.07

Air Entering Evaporator Cfm/BF


4500/0.09
5000/0.10
Air Entering Evaporator Ewb (F)
72
67
62
72
67
62
181.0 167.5 154.2 182.9 170.2 156.4
91.4 116.2 140.3
94.2 122.2 146.5
11.32 11.00 10.69 11.37 11.07 10.73
174.2 160.7 147.0 176.9 163.0 149.7
89.6 113.9 137.0
92.7 119.7 143.6
12.31 11.94 11.58 12.39 12.01 11.63
166.8 153.5 139.1 169.5 155.7 142.8
87.0 111.1 133.2
90.7 117.3 140.2
13.30 12.89 12.46 13.40 12.97 12.56
158.8 145.4 130.2 160.9 147.6 135.0
84.5 108.2 128.1
87.8 114.3 134.9
14.31 13.82 13.35 14.38 13.91 13.48
150.5 137.0 122.4 152.3 139.4 127.8
81.7 105.2 122.3
85.0 111.6 127.7
15.30 14.76 14.25 15.37 14.87 14.43

6250/0.12
72
187.2
102.1
11.49
181.5
100.9
12.53
173.2
98.3
13.54
165.3
96.6
14.58
155.2
92.9
15.49

67
174.7
135.3
11.19
167.3
133.4
12.14
159.5
130.8
13.11
151.2
127.8
14.07
142.7
125.0
15.02

62
161.8
160.7
10.87
155.8
155.6
11.82
149.6
149.6
12.78
143.2
143.1
13.77
136.0
135.8
14.73

31

Performance data 50TFF (cont)

50TFF

FAN PERFORMANCE VERTICAL DISCHARGE UNITS


50TFF004 (3 TONS) STANDARD MOTOR (Direct Drive)
Low Speed
Airflow
208 v
230, 460, 575 v
(Cfm)
ESP
Bhp
Watts
ESP
Bhp
Watts
900
0.67
0.21
253
0.68
0.23
277
1000
0.60
0.23
270
0.61
0.25
292
1100
0.55
0.24
287
0.56
0.26
307
1200
0.51
0.26
304
0.51
0.27
323
1300
0.45
0.27
321
0.46
0.29
338
1400
0.38
0.29
338
0.41
0.30
354
1500
0.34
0.30
355
0.36
0.31
369
LEGEND
Bhp
Brake Horsepower Input to Fan
ESP External Static Pressure (in. wg)
Watts Input Watts to Motor

High Speed
ESP
0.69
0.61
0.57
0.52
0.46
0.43
0.38

208 v
Bhp
0.26
0.27
0.28
0.29
0.31
0.32
0.33

Watts
307
321
335
349
364
378
392

ESP
0.69
0.63
0.58
0.53
0.47

230, 460, 575 v


Bhp
Watts
0.31
363
0.32
374
0.33
385
0.34
397
0.34
408

See general fan performance notes below.

50TFF004 (3 TONS) ALTERNATE MOTOR (Belt Drive)*


External Static Pressure (in. wg)
0.6
Watts
Rpm
Bhp
Watts
Rpm
222
870
0.30
296
958
268
904
0.35
348
991
321
939
0.41
407
1025
382
976
0.48
474
1060
451
1013
0.55
550
1095
529
1051
0.64
636
1132
617
1090
0.74
731
1169

0.8
Bhp
0.37
0.43
0.50
0.57
0.66
0.75
0.85

Watts
373
430
496
570
652
744
846

Rpm
1037
1069
1102
1136
1170
1205
1242

1.0
Bhp
0.46
0.52
0.59
0.67
0.76
0.86
0.97

Watts
454
517
588
668
756
855
963

50TFF004 (3 TONS) ALTERNATE MOTOR (Belt Drive)* (cont)


External Static Pressure (in. wg)
Airflow
1.2
1.4
1.6
(Cfm)
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
900
1110
0.54
538
1177
0.63
627
1239
0.72
718
1298
1000
1141
0.61
607
1207
0.70
700
1269
0.80
796
1328
1100
1173
0.69
683
1238
0.79
781
1300
0.89
883
1358
1200
1205
0.77
768
1270
0.88
872
1332
0.98
979
1389
1300
1239
0.87
863
1303
0.98
972
1364
1.09
1084

1400
1273
0.97
967
1337
1.09
1082

1500
1309
1.09
1082

1.8
Bhp
0.82
0.90
0.99
1.09

Watts
813
895
987
1088

Rpm
1355
1384
1414

2.0
Bhp
0.92
1.00
1.10

Watts
911
998
1094

Airflow
(Cfm)
900
1000
1100
1200
1300
1400
1500

Rpm
643
683
725
767
811
855
900

0.2
Bhp
0.15
0.19
0.24
0.29
0.35
0.43
0.51

Watts
152
191
237
291
352
423
504

Rpm
768
804
842
880
920
960
1002

0.4
Bhp
0.22
0.27
0.32
0.38
0.45
0.53
0.62

LEGEND
Bhp
Brake Horsepower Input to Fan
Watts Input Watts to Motor

NOTES:
1. Boldface indicates field-supplied drive is required.
2. Maximum continuous bhp is 1.20.
3. See below for general fan performance notes.

*Motor drive range: 760 to 1000 rpm. All other rpms require fieldsupplied drive.

GENERAL FAN PERFORMANCE NOTES


1. Values include losses for filters, unit casing, and wet coils.
2. Extensive motor and electrical testing on these units ensures that the full range
of the motor can be utilized with confidence. Using your fan motors up to the
wattage ratings shown will not result in nuisance tripping or premature motor
failure. Unit warranty will not be affected. For additional information on motor
performance, refer to Evaporator Fan Motor Performance table on page 65.
3. Use of a field-supplied motor may affect wire sizing. Contact your Carrier representative for details.
4. Interpolation is permissible. Do not extrapolate.

32

FAN PERFORMANCE VERTICAL DISCHARGE UNITS (cont)


50TFF004 (3 TONS) HIGH-STATIC MOTOR (Belt Drive)*
0.8
Bhp
0.37
0.43
0.50
0.57
0.66
0.75
0.85

Watts
373
430
496
570
652
744
846

Rpm
1037
1069
1102
1136
1170
1205
1242

1.0
Bhp
0.46
0.52
0.59
0.67
0.76
0.86
0.97

Watts
454
517
588
668
756
855
963

50TFF004 (3 TONS) HIGH-STATIC MOTOR (Belt Drive)* (cont)


External Static Pressure (in. wg)
Airflow
1.2
1.4
1.6
(Cfm)
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
900
1110
0.54
538
1177
0.63
627
1239
0.72
718
1298
1000
1141
0.61
607
1207
0.70
700
1269
0.80
796
1328
1100
1173
0.69
683
1238
0.79
781
1300
0.89
883
1358
1200
1205
0.77
768
1270
0.88
872
1332
0.98
979
1389
1300
1239
0.87
863
1303
0.98
972
1364
1.09
1084
1421
1400
1273
0.97
967
1337
1.09
1082
1397
1.21
1200
1453
1500
1309
1.09
1082
1371
1.21
1204
1430
1.33
1327
1486

1.8
Bhp
0.82
0.90
0.99
1.09
1.21
1.33
1.46

Watts
813
895
987
1088
1199
1320
1453

Rpm
1355
1384
1414
1444
1475
1507
1540

2.0
Bhp
0.92
1.00
1.10
1.21
1.32
1.45
1.59

Watts
911
998
1094
1200
1316
1443
1581

900
1000
1100
1200
1300
1400
1500

Rpm
643
683
725
767
811
855
900

0.2
Bhp
0.15
0.19
0.24
0.29
0.35
0.43
0.51

Watts
152
191
237
291
352
423
504

Rpm
768
804
842
880
920
960
1002

0.4
Bhp
0.22
0.27
0.32
0.38
0.45
0.53
0.62

LEGEND
Bhp
Brake Horsepower Input to Fan
Watts Input Watts to Motor

NOTES:
1. Boldface indicates field-supplied drive is required.
2. Maximum continuous bhp is 2.40.
3. See page 32 for general fan performance notes.

*Motor drive range: 1075 to 1455 rpm. All other rpms require fieldsupplied drive.

50TFF005 (4 TONS) STANDARD MOTOR (Belt Drive)


Low Speed
Airflow
208
v
230, 460, 575 v
(Cfm)
ESP
Bhp
Watts
ESP
Bhp
Watts
1200
0.93
0.41
458
0.94
0.45
506
1300
0.86
0.42
471
0.87
0.46
521
1400
0.78
0.45
503
0.79
0.49
556
1500
0.70
0.47
536
0.73
0.52
593
1600
0.61
0.49
557
0.64
0.54
616
1700
0.51
0.52
584
0.54
0.57
646
1800
0.40
0.54
610
0.44
0.60
674
1900
0.29
0.56
629
0.37
0.62
696
2000
0.25
0.58
651
0.30
0.64
720

High Speed
ESP
0.94
0.87
0.79
0.73
0.66
0.58
0.51
0.46
0.39

208 v
Bhp
0.51
0.52
0.54
0.56
0.58
0.60
0.62
0.64
0.66

Watts
572
589
616
631
654
678
698
720
744

ESP
0.99
0.92
0.87
0.80
0.76
0.68
0.63
0.56
0.50

230, 460, 575 v


Bhp
Watts
0.56
632
0.58
651
0.60
681
0.62
698
0.64
723
0.66
750
0.68
772
0.70
796
0.73
823

See general fan performance notes on page 32.


LEGEND
Bhp
Brake Horsepower Input to Fan
ESP External Static Pressure (in. wg)
Watts Input Watts to Motor

33

50TFF

External Static Pressure (in. wg)


0.6
Watts
Rpm
Bhp
Watts
Rpm
222
870
0.30
296
958
268
904
0.35
348
991
321
939
0.41
407
1025
382
976
0.48
474
1060
451
1013
0.55
550
1095
529
1051
0.64
636
1132
617
1090
0.74
731
1169

Airflow
(Cfm)

Performance data 50TFF (cont)


FAN PERFORMANCE VERTICAL DISCHARGE UNITS (cont)
50TFF005 (4 TONS) ALTERNATE MOTOR (Belt Drive)
External Static Pressure (in. wg)
0.6
Watts
Rpm
Bhp
Watts
Rpm
361
873
0.48
476
956
418
902
0.54
540
983
481
932
0.61
610
1012
551
962
0.69
689
1041
629
994
0.78
774
1071
715
1026
0.87
869
1101
810
1059
0.98
972
1133
914
1092
1.09
1084

1028

0.8
Bhp
0.60
0.67
0.75
0.83
0.93
1.03
1.14

Watts
594
665
744
830
923
1025
1136

Rpm
1031
1057
1085
1112
1141
1170

1.0
Bhp
0.72
0.80
0.89
0.98
1.08
1.19

Watts
718
796
881
974
1076
1185

50TFF005 (4 TONS) ALTERNATE MOTOR (Belt Drive) (cont)


External Static Pressure (in. wg)
Airflow
1.2
1.4
1.6
(Cfm)
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
1200
1100
0.85
845
1165
0.98
977
1225
1.12
1112

1300
1126
0.94
930
1189
1.07
1069

1400
1152
1.03
1023
1215
1.17
1168

1500
1179
1.13
1123

1600

1700

1800

1900

2000

1.8
Bhp

Watts

Rpm

2.0
Bhp

Watts

Airflow
(Cfm

50TFF

1200
1300
1400
1500
1600
1700
1800
1900
2000

Rpm
666
701
737
774
811
849
887
926
965

0.2
Bhp
0.25
0.30
0.36
0.42
0.49
0.57
0.65
0.75
0.86

Watts
252
300
355
417
487
565
651
746
852

Rpm
778
809
842
875
909
943
978
1014
1050

0.4
Bhp
0.36
0.42
0.48
0.55
0.63
0.72
0.81
0.92
1.03

LEGEND
Bhp
Brake Horsepower Input to Fan
Watts Input Watts to Motor

NOTES:
1. Boldface indicates field-supplied drive is required.
2. Maximum continuous bhp is 1.20.
3. See page 32 for general fan performance notes.

*Motor drive range: 835 to 1185 rpm. All other rpms require fieldsupplied drive.

50TFF005 (4 TONS) HIGH-STATIC MOTOR (Belt Drive)*


External Static Pressure (in. wg)
0.6
Watts
Rpm
Bhp
Watts
Rpm
361
873
0.48
476
956
418
902
0.54
540
983
481
932
0.61
610
1012
551
962
0.69
689
1041
629
994
0.78
774
1071
715
1026
0.87
869
1101
810
1059
0.98
972
1133
914
1092
1.09
1084
1164
1028
1127
1.21
1206
1197

0.8
Bhp
0.60
0.67
0.75
0.83
0.93
1.03
1.14
1.26
1.39

Watts
594
665
744
830
923
1025
1136
1257
1387

Rpm
1031
1057
1085
1112
1141
1170
1200
1231
1262

1.0
Bhp
0.72
0.80
0.89
0.98
1.08
1.19
1.31
1.44
1.58

Watts
718
796
881
974
1076
1185
1304
1432
1570

50TFF005 (4 TONS) HIGH-STATIC MOTOR (Belt Drive)* (cont)


External Static Pressure (in. wg)
Airflow
1.2
1.4
1.6
(Cfm)
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
1200
1100
0.85
845
1165
0.98
977
1225
1.12
1112
1282
1300
1126
0.94
930
1189
1.07
1069
1249
1.22
1211
1306
1400
1152
1.03
1023
1215
1.17
1168
1274
1.32
1317
1330
1500
1179
1.13
1123
1241
1.28
1275
1300
1.44
1431
1355
1600
1206
1.24
1231
1268
1.40
1391
1326
1.56
1553
1381
1700
1235
1.36
1349
1295
1.52
1515
1352
1.69
1685
1407
1800
1264
1.48
1475
1323
1.66
1649
1380
1.84
1826
1434
1900
1293
1.62
1611
1352
1.80
1792
1408
1.99
1976
1461
2000
1324
1.77
1756
1381
1.96
1945
1436
2.15
2137
1489

1.8
Bhp
1.26
1.36
1.48
1.60
1.73
1.87
2.02
2.17
2.34

Watts
1252
1356
1469
1590
1719
1858
2006
2163
2332

Rpm
1337
1360
1384
1408
1433
1459
1485
1512

2.0
Bhp
1.40
1.51
1.63
1.76
1.90
2.04
2.20
2.37

Watts
1395
1506
1625
1752
1888
2034
2189
2353

Airflow
(Cfm)
1200
1300
1400
1500
1600
1700
1800
1900
2000

Rpm
666
701
737
774
811
849
887
926
965

0.2
Bhp
0.25
0.30
0.36
0.42
0.49
0.57
0.65
0.75
0.86

Watts
252
300
355
417
487
565
651
746
852

Rpm
778
809
842
875
909
943
978
1014
1050

0.4
Bhp
0.36
0.42
0.48
0.55
0.63
0.72
0.81
0.92
1.03

LEGEND
Bhp
Brake Horsepower Input to Fan
Watts Input Watts to Motor
*Motor drive range: 1075 to 1455 rpm. All other rpms require fieldsupplied drive.

34

NOTES:
1. Boldface indicates field-supplied drive is required.
2. Maximum continuous bhp is 2.40.
3. See page 32 for general fan performance notes.

FAN PERFORMANCE VERTICAL DISCHARGE UNITS (cont)

ESP
1.19
1.04
0.89
0.74
0.59
0.44
0.29
0.19
0.11
0.04

208 v
Bhp
0.70
0.74
0.77
0.81
0.84
0.88
0.91
0.93
0.97
1.00

LEGEND
Bhp
Brake Horsepower Input to Fan
ESP External Static Pressure (in. wg)
Watts Input Watts to Motor

Medium Speed
230, 460, 575 v
Watts ESP Bhp Watts
782 1.36 0.76
845
821 1.22 0.79
883
861 1.09 0.83
921
900 0.96 0.86
959
940 0.86 0.90
997
979 0.73 0.93 1035
1018 0.59 0.96 1073
1035 0.46 1.00 1111
1076 0.34 1.03 1149
1113 0.19 1.07 1187

0.09 1.10 1225

ESP
1.38
1.25
1.13
1.00
0.88
0.78
0.63
0.49
0.41
0.22
0.12

208 v
Bhp
0.79
0.82
0.85
0.89
0.92
0.95
0.99
1.02
1.06
1.09
1.12

High Speed
230, 460, 575 v
Watts ESP Bhp Watts
875
1.44 0.85
949
913
1.33 0.89
988
950
1.22 0.92 1027
988
1.11 0.96 1066
1025
1.00 0.99 1105
1063
0.92 1.03 1144
1101
0.81 1.06 1183
1138
0.69 1.10 1222
1176
0.59 1.13 1261
1213
0.43 1.17 1300
1251
0.34 1.20 1340

See general fan performance notes on page 32.

50TFF006 (5 TONS) ALTERNATE MOTOR (Belt Drive)*


External Static Pressure (in. wg)
0.6
Watts
Rpm
Bhp
Watts
Rpm
489
1011
0.71
621
1103
557
1042
0.79
694
1130
632
1073
0.88
774
1158
715
1106
0.98
863
1188
808
1140
1.09
960
1219
909
1175
1.21
1066
1251
1019
1211
1.35
1182
1285
1140
1247
1.49
1308
1319
1271
1284
1.65
1445
1353
1412
1322
1.81
1592
1389
1565
1360
1.99
1751
1425

0.8
Bhp
0.87
0.96
1.06
1.16
1.28
1.41
1.54
1.69
1.85
2.03
2.22

Watts
766
843
928
1021
1123
1234
1355
1486
1628
1781
1945

Rpm
1188
1213
1239
1266
1295
1325
1355
1387
1420
1454

1.0
Bhp
1.05
1.14
1.24
1.35
1.48
1.61
1.75
1.91
2.07
2.25

Watts
923
1003
1092
1189
1296
1411
1537
1673
1820
1977

50TFF006 (5 TONS) ALTERNATE MOTOR (Belt Drive)* (cont)


External Static Pressure (in. wg)
Airflow
1.2
1.4
1.6
(Cfm)
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
1500
1270
1.24
1091
1347
1.45
1269
1421
1.66
1458
1492
1600
1292
1.34
1174
1367
1.54
1356
1440
1.76
1547
1509
1700
1315
1.44
1267
1389
1.65
1451
1459
1.88
1646
1527
1800
1341
1.56
1368
1412
1.77
1556
1481
2.00
1753
1547
1900
1367
1.68
1478
1437
1.90
1670
1504
2.13
1871
1569
2000
1395
1.82
1598
1463
2.04
1794
1528
2.28
1998

2100
1424
1.97
1728
1490
2.20
1928

2200
1454
2.13
1869
1518
2.36
2073

2300
1485
2.30
2020

2400

2500

1.8
Bhp
1.89
1.99
2.11
2.23
2.37

Watts
1657
1748
1849
1960
2080

Rpm
1561
1576
1593

2.0
Bhp
2.13
2.23
2.35

Watts
1865
1959
2062

Airflow
(Cfm)
1500
1600
1700
1800
1900
2000
2100
2200
2300
2400
2500

Rpm
807
847
887
928
969
1010
1052
1095
1137
1180
1223

0.2
Bhp
0.42
0.49
0.57
0.66
0.76
0.87
0.99
1.12
1.26
1.41
1.58

Watts
369
432
501
579
666
761
866
981
1105
1241
1388

Rpm
913
948
983
1020
1057
1095
1133
1173
1212
1252
1293

0.4
Bhp
0.56
0.63
0.72
0.82
0.92
1.04
1.16
1.30
1.45
1.61
1.78

LEGEND
Bhp
Brake Horsepower Input to Fan
Watts Input Watts to Motor
*Motor drive range: 900 to 1300 rpm. All other rpms require fieldsupplied drive.

NOTES:
1. Boldface indicates field-supplied drive is required.
2. Maximum continuous bhp is 1.30 for single-phase units and 2.40 for
three-phase units.
3. See page 32 for general fan performance notes.

35

50TFF

50TFF006 (5 TONS) STANDARD MOTOR (Belt Drive)


Low Speed
Airflow
208 v
230, 460, 575 v
(Cfm)
ESP Bhp Watts ESP Bhp Watts
1500
0.88 0.67
750
1.20 0.71
791
1600
0.68 0.70
780
1.04 0.74
824
1700
0.51 0.73
810
0.89 0.77
857
1800
0.35 0.75
839
0.73 0.80
891
1900
0.26 0.78
873
0.58 0.83
924
2000
0.18 0.81
905
0.42 0.86
957
2100
0.08 0.84
940
0.27 0.89
990
2200

0.19 0.92 1023


2300

0.11 0.95 1056


2400

0.03 0.98 1096


2500

Performance data 50TFF (cont)


FAN PERFORMANCE VERTICAL DISCHARGE UNITS (cont)
50TFF006 (5 TONS) HIGH-STATIC MOTOR (Belt Drive)*
External Static Pressure (in. wg)
0.6
Watts
Rpm
Bhp
Watts
Rpm
489
1011
0.71
621
1103
557
1042
0.79
694
1130
632
1073
0.88
774
1158
715
1106
0.98
863
1188
808
1140
1.09
960
1219
909
1175
1.21
1066
1251
1019
1211
1.35
1182
1285
1140
1247
1.49
1308
1319
1271
1284
1.65
1445
1353
1412
1322
1.81
1592
1389
1565
1360
1.99
1751
1425

0.8
Bhp
0.87
0.96
1.06
1.16
1.28
1.41
1.54
1.69
1.85
2.03
2.22

Watts
766
843
928
1021
1123
1234
1355
1486
1628
1781
1945

Rpm
1188
1213
1239
1266
1295
1325
1355
1387
1420
1454
1488

1.0
Bhp
1.05
1.14
1.24
1.35
1.48
1.61
1.75
1.91
2.07
2.25
2.45

Watts
923
1003
1092
1189
1296
1411
1537
1673
1820
1977
2147

50TFF006 (5 TONS) HIGH-STATIC MOTOR (Belt Drive)* (cont)


External Static Pressure (in. wg)
Airflow
1.2
1.4
1.6
(Cfm)
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
1500
1270
1.24
1091
1347
1.45
1269
1421
1.66
1458
1492
1600
1292
1.34
1174
1367
1.54
1356
1440
1.76
1547
1509
1700
1315
1.44
1267
1389
1.65
1451
1459
1.88
1646
1527
1800
1341
1.56
1368
1412
1.77
1556
1481
2.00
1753
1547
1900
1367
1.68
1478
1437
1.90
1670
1504
2.13
1871
1569
2000
1395
1.82
1598
1463
2.04
1794
1528
2.28
1998
1591
2100
1424
1.97
1728
1490
2.20
1928
1554
2.43
2136
1615
2200
1454
2.13
1869
1518
2.36
2073
1580
2.60
2285
1641
2300
1485
2.30
2020
1547
2.54
2228
1608
2.79
2445

2400
1516
2.49
2182
1577
2.73
2395

2500
1549
2.69
2357

1.8
Bhp
1.89
1.99
2.11
2.23
2.37
2.52
2.68
2.85

Watts
1657
1748
1849
1960
2080
2212
2353
2505

Rpm
1561
1576
1593
1612
1632
1653

2.0
Bhp
2.13
2.23
2.35
2.48
2.62
2.77

Watts
1865
1959
2062
2175
2299
2433

Airflow
(Cfm)

50TFF

1500
1600
1700
1800
1900
2000
2100
2200
2300
2400
2500

Rpm
807
847
887
928
969
1010
1052
1095
1137
1180
1223

0.2
Bhp
0.42
0.49
0.57
0.66
0.76
0.87
0.99
1.12
1.26
1.41
1.58

Watts
369
432
501
579
666
761
866
981
1105
1241
1388

Rpm
913
948
983
1020
1057
1095
1133
1173
1212
1252
1293

0.4
Bhp
0.56
0.63
0.72
0.82
0.92
1.04
1.16
1.30
1.45
1.61
1.78

LEGEND
Bhp
Brake Horsepower Input to Fan
Watts Input Watts to Motor
*Motor drive range: 1300 to 1685 rpm. All other rpms require fieldsupplied drive.

36

NOTES:
1. Boldface indicates field-supplied drive is required.
2. Maximum continuous bhp is 2.90.
3. See page 32 for general fan performance notes.

FAN PERFORMANCE VERTICAL DISCHARGE UNITS (cont)


50TFF007 (6 TONS) STANDARD MOTOR (Belt Drive)*
0.8
Bhp
1.11
1.22
1.34
1.47
1.61
1.76
1.93
2.10
2.29

Watts
985
1084
1190
1306
1431
1567
1712
1868
2035

Rpm
1238
1268
1299
1330
1362
1395
1428
1462

1.0
Bhp
1.29
1.41
1.53
1.67
1.82
1.98
2.15
2.33

Watts
1148
1251
1362
1483
1614
1754
1905
2067

50TFF007 (6 TONS) STANDARD MOTOR (Belt Drive)* (cont)


External Static Pressure (in. wg)
Airflow
1.2
1.4
1.6
(Cfm)
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
1800
1306
1.48
1318
1370
1.69
1497
1431
1.90
1683
1489
1900
1335
1.61
1426
1398
1.81
1609
1458
2.03
1799
1515
2000
1364
1.74
1542
1427
1.95
1730
1486
2.17
1925
1542
2100
1395
1.88
1668
1456
2.09
1860
1514
2.32
2060

2200
1426
2.03
1804
1486
2.25
2001

2300
1457
2.19
1949

2400
1489
2.37
2106

2500

2600

2700

2800

2900

3000

1.8
Bhp
2.11
2.25
2.39

Watts
1877
1997
2126

Rpm
1545

2.0
Bhp
2.34

Watts
2078

1800
1900
2000
2100
2200
2300
2400
2500
2600
2700
2800
2900
3000

Rpm
905
944
983
1023
1063
1104
1145
1185
1227
1268
1309
1351

0.2
Bhp
0.62
0.71
0.81
0.92
1.05
1.18
1.32
1.48
1.64
1.82
2.02
2.23

Watts
551
633
723
821
929
1046
1174
1311
1460
1621
1793
1977

Rpm
1001
1037
1073
1110
1147
1185
1223
1262
1301
1340
1379

0.4
Bhp
0.77
0.87
0.98
1.10
1.23
1.37
1.52
1.68
1.85
2.04
2.24

LEGEND
Bhp
Brake Horsepower Input to Fan
Watts Input Watts to Motor
*Motor drive range: 1070 to 1460 rpm. All other rpms require fieldsupplied drive.

NOTES:
1. Boldface indicates field-supplied drive is required.
2. Maximum continuous bhp is 2.40.
3. See page 32 for general fan performance notes.

37

50TFF

External Static Pressure (in. wg)


0.6
Watts
Rpm
Bhp
Watts
Rpm
687
1087
0.94
832
1165
774
1120
1.04
925
1197
870
1154
1.16
1026
1229
975
1189
1.28
1137
1262
1089
1224
1.41
1256
1295
1212
1260
1.56
1386
1329
1346
1296
1.72
1526
1364
1490
1333
1.89
1676
1399
1646
1370
2.07
1837
1435
1812
1407
2.26
2010

1991

Airflow
(Cfm)

Performance data 50TFF (cont)


FAN PERFORMANCE VERTICAL DISCHARGE UNITS (cont)
50TFF007 (6 TONS) HIGH-STATIC MOTOR (Belt Drive)*
External Static Pressure (in. wg)
0.6
Watts
Rpm
Bhp
Watts
Rpm
687
1087
0.94
832
1165
774
1120
1.04
925
1197
870
1154
1.16
1026
1229
975
1189
1.28
1137
1262
1089
1224
1.41
1256
1295
1212
1260
1.56
1386
1329
1346
1296
1.72
1526
1364
1490
1333
1.89
1676
1399
1646
1370
2.07
1837
1435
1812
1407
2.26
2010
1470
1991
1445
2.47
2195
1507
2181
1483
2.69
2392

2385

0.8
Bhp
1.11
1.22
1.34
1.47
1.61
1.76
1.93
2.10
2.29
2.49
2.71

Watts
985
1084
1190
1306
1431
1567
1712
1868
2035
2214
2405

Rpm
1238
1268
1299
1330
1362
1395
1428
1462
1496
1531

1.0
Bhp
1.29
1.41
1.53
1.67
1.82
1.98
2.15
2.33
2.52
2.73

Watts
1148
1251
1362
1483
1614
1754
1905
2067
2240
2424

50TFF007 (6 TONS) HIGH-STATIC MOTOR (Belt Drive)* (cont)


External Static Pressure (in. wg)
Airflow
1.2
1.4
1.6
(Cfm)
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
1800
1306
1.48
1318
1370
1.69
1497
1431
1.90
1683
1489
1900
1335
1.61
1426
1398
1.81
1609
1458
2.03
1799
1515
2000
1364
1.74
1542
1427
1.95
1730
1486
2.17
1925
1542
2100
1395
1.88
1668
1456
2.09
1860
1514
2.32
2060
1570
2200
1426
2.03
1804
1486
2.25
2001
1543
2.48
2204
1598
2300
1457
2.19
1949
1516
2.42
2151
1573
2.66
2360
1627
2400
1489
2.37
2106
1547
2.60
2312
1603
2.84
2526

2500
1522
2.56
2272
1579
2.80
2484

2600
1555
2.76
2451

2700

2800

2900

3000

1.8
Bhp
2.11
2.25
2.39
2.55
2.72
2.90

Watts
1877
1997
2126
2265
2415
2574

Rpm
1545
1570
1596
1623

2.0
Bhp
2.34
2.48
2.63
2.79

Watts
2078
2202
2335
2478

Airflow
(Cfm)

50TFF

1800
1900
2000
2100
2200
2300
2400
2500
2600
2700
2800
2900
3000

Rpm
905
944
983
1023
1063
1104
1145
1185
1227
1268
1309
1351
1393

0.2
Bhp
0.62
0.71
0.81
0.92
1.05
1.18
1.32
1.48
1.64
1.82
2.02
2.23
2.45

Watts
551
633
723
821
929
1046
1174
1311
1460
1621
1793
1977
2174

Rpm
1001
1037
1073
1110
1147
1185
1223
1262
1301
1340
1379
1419
1459

0.4
Bhp
0.77
0.87
0.98
1.10
1.23
1.37
1.52
1.68
1.85
2.04
2.24
2.46
2.69

LEGEND
Bhp
Brake Horsepower Input to Fan
Watts Input Watts to Motor
*Motor drive range: 1300 to 1685 rpm. All other rpms require fieldsupplied drive.

38

NOTES:
1. Boldface indicates field-supplied drive is required.
2. Maximum continuous bhp is 2.90.
3. See page 32 for general fan performance notes.

FAN PERFORMANCE VERTICAL DISCHARGE UNITS (cont)


50TFF008 (71/2 TONS) STANDARD MOTOR (Belt Drive)*
Airflow
(Cfm)

Watts
538
567
630
698
733
770
848
932
1020
1115
1217
1324
1438
1558
1686
1820
1962
2036

Rpm
591
597
611
624
631
638
652
667
681
696
711
726
741
756
772
787
803

0.4
Bhp
0.75
0.78
0.86
0.93
0.98
1.02
1.11
1.21
1.31
1.42
1.53
1.65
1.78
1.92
2.06
2.21
2.37

External Static Pressure (in. wg)


0.6
Watts
Rpm
Bhp
Watts
Rpm
697
660
0.93
864
722
729
666
0.97
900
727
798
678
1.04
974
739
872
690
1.13
1053
750
910
697
1.17
1095
756
950
703
1.22
1138
762
1034
716
1.32
1228
774
1124
729
1.42
1323
786
1220
743
1.53
1425
799
1321
756
1.64
1532
812
1428
770
1.76
1645
825
1542
784
1.89
1765
838
1663
798
2.03
1892
851
1790
812
2.17
2025

1923
827
2.32
2165

2065

2213

0.8
Bhp
1.12
1.16
1.24
1.33
1.38
1.43
1.53
1.64
1.75
1.88
2.00
2.14
2.28

Watts
1041
1079
1158
1243
1287
1333
1428
1529
1636
1749
1869
1994
2126

Rpm
779
784
794
805
811
816
828
839
851
863
875
888

1.0
Bhp
1.32
1.36
1.45
1.55
1.60
1.65
1.75
1.87
1.99
2.12
2.25
2.39

Watts
1228
1268
1352
1441
1488
1536
1636
1742
1855
1973
2098
2229

1.8
Bhp
2.21
2.26
2.37

Watts
2061
2109
2209

Rpm

2.0
Bhp

Watts

50TFF008 (71/2 TONS) STANDARD MOTOR (Belt Drive)* (cont)


Airflow
(Cfm)
2250
2300
2400
2500
2550
2600
2700
2800
2900
3000
3100
3200
3300
3400
3500
3600
3700
3750

Rpm
831
836
846
856
862
867
878
889
900
912

1.2
Bhp
1.53
1.57
1.67
1.77
1.82
1.87
1.99
2.11
2.23
2.36

Watts
1423
1465
1554
1647
1697
1747
1852
1963
2080
2204

Rpm
880
885
895
905
910
915
925
936

1.4
Bhp
1.74
1.79
1.89
2.00
2.05
2.11
2.23
2.35

External Static Pressure (in. wg)


1.6
Watts
Rpm
Bhp
Watts
Rpm
1627
927
1.97
1840
971
1671
931
2.02
1886
975
1764
941
2.13
1982
984
1862
950
2.24
2085

1913
955
2.29
2138

1966
960
2.35
2193

2076

2192

LEGEND
Bhp
Brake Horsepower Input to Fan
Watts Input Watts to Motor
*Motor drive range: 590 to 840 rpm. All other rpms require fieldsupplied drive.

NOTES:
1. Boldface indicates field-supplied drive is required.
2. Maximum continuous bhp is 2.40.
3. See page 32 for general fan performance notes.

39

50TFF

2250
2300
2400
2500
2550
2600
2700
2800
2900
3000
3100
3200
3300
3400
3500
3600
3700
3750

Rpm
511
519
534
550
557
565
581
597
613
629
646
662
679
695
712
729
746
754

0.2
Bhp
0.58
0.61
0.68
0.75
0.79
0.83
0.91
1.00
1.09
1.20
1.30
1.42
1.54
1.67
1.81
1.95
2.10
2.18

Performance data 50TFF (cont)


FAN PERFORMANCE VERTICAL DISCHARGE UNITS (cont)
50TFF008 (71/2 TONS) ALTERNATE MOTOR (Belt Drive)*
AIRFLOW
(Cfm)

50TFF

2250
2300
2400
2500
2550
2600
2700
2800
2900
3000
3100
3200
3300
3400
3500
3600
3700
3750

Rpm
511
519
534
550
557
565
581
597
613
629
646
662
679
695
712
729
746
754

0.2
Bhp
0.58
0.61
0.68
0.75
0.79
0.83
0.91
1.00
1.09
1.20
1.30
1.42
1.54
1.67
1.81
1.95
2.10
2.18

Watts
538
567
630
698
733
770
848
932
1020
1115
1217
1324
1438
1558
1686
1820
1962
2036

Rpm
591
597
611
624
631
638
652
667
681
696
711
726
741
756
772
787
803

0.4
Bhp
0.75
0.78
0.86
0.93
0.98
1.02
1.11
1.21
1.31
1.42
1.53
1.65
1.78
1.92
2.06
2.21
2.37

EXTERNAL STATIC PRESSURE (in. wg)


0.6
Watts
Rpm
Bhp
Watts
Rpm
697
660
0.93
864
722
729
666
0.97
900
727
798
678
1.04
974
739
872
690
1.13
1053
750
910
697
1.17
1095
756
950
703
1.22
1138
762
1034
716
1.32
1228
774
1124
729
1.42
1323
786
1220
743
1.53
1425
799
1321
756
1.64
1532
812
1428
770
1.76
1645
825
1542
784
1.89
1765
838
1663
798
2.03
1892
851
1790
812
2.17
2025

1923
827
2.32
2165

2065

2213

0.8
Bhp
1.12
1.16
1.24
1.33
1.38
1.43
1.53
1.64
1.75
1.88
2.00
2.14
2.28

Watts
1041
1079
1158
1243
1287
1333
1428
1529
1636
1749
1869
1994
2126

Rpm
779
784
794
805
811
816
828
839
851
863
875
888

1.0
Bhp
1.32
1.36
1.45
1.55
1.60
1.65
1.75
1.87
1.99
2.12
2.25
2.39

Watts
1228
1268
1352
1441
1488
1536
1636
1742
1855
1973
2098
2229

1.8
Bhp
2.21
2.26
2.37

Watts
2061
2109
2209

Rpm

2.0
Bhp

Watts

50TFF008 (71/2 TONS) ALTERNATE MOTOR (Belt Drive)* (cont)


AIRFLOW
(Cfm)
2250
2300
2400
2500
2550
2600
2700
2800
2900
3000
3100
3200
3300
3400
3500
3600
3700
3750

Rpm
831
836
846
856
862
867
878
889
900
912

1.2
Bhp
1.53
1.57
1.67
1.77
1.82
1.87
1.99
2.11
2.23
2.36

Watts
1423
1465
1554
1647
1697
1747
1852
1963
2080
2204

Rpm
880
885
895
905
910
915
925
936

1.4
Bhp
1.74
1.79
1.89
2.00
2.05
2.11
2.23
2.35

EXTERNAL STATIC PRESSURE (in. wg)


1.6
Watts
Rpm
Bhp
Watts
Rpm
1627
927
1.97
1840
971
1671
931
2.02
1886
975
1764
941
2.13
1982
984
1862
950
2.24
2085

1913
955
2.29
2138

1966
960
2.35
2193

2076

2192

LEGEND
Bhp
Brake Horsepower Input to Fan
Watts Input Watts to Motor
*Motor drive range: 685 to 935 rpm. All other rpms require fieldsupplied drive.

40

NOTES:
1. Boldface indicates field-supplied drive is required.
2. Maximum continuous bhp is 2.40.
3. See page 32 for general fan performance notes.

FAN PERFORMANCE DATA VERTICAL DISCHARGE UNITS (cont)


50TFF008 (71/2 TONS) HIGH-STATIC MOTOR (Belt Drive)*
Airflow
(Cfm)

Watts
538
567
630
698
733
770
848
932
1020
1115
1217
1324
1438
1558
1686
1820
1962
2036

Rpm
591
597
611
624
631
638
652
667
681
696
711
726
741
756
772
787
803
811

0.4
Bhp
0.75
0.78
0.86
0.93
0.98
1.02
1.11
1.21
1.31
1.42
1.53
1.65
1.78
1.92
2.06
2.21
2.37
2.46

External Static Pressure (in. wg)


0.6
Watts
Rpm
Bhp
Watts
Rpm
697
660
0.93
864
722
729
666
0.97
900
727
798
678
1.04
974
739
872
690
1.13
1053
750
910
697
1.17
1095
756
950
703
1.22
1138
762
1034
716
1.32
1228
774
1124
729
1.42
1323
786
1220
743
1.53
1425
799
1321
756
1.64
1532
812
1428
770
1.76
1645
825
1542
784
1.89
1765
838
1663
798
2.03
1892
851
1790
812
2.17
2025
865
1923
827
2.32
2165
878
2065
841
2.48
2312
892
2213
856
2.65
2467
906
2290
864
2.73
2548
913

0.8
Bhp
1.12
1.16
1.24
1.33
1.38
1.43
1.53
1.64
1.75
1.88
2.00
2.14
2.28
2.43
2.59
2.75
2.92
3.01

Watts
1041
1079
1158
1243
1287
1333
1428
1529
1636
1749
1869
1994
2126
2266
2412
2565
2726
2809

Rpm
779
784
794
805
811
816
828
839
851
863
875
888
901
913
926
940
953
960

1.0
Bhp
1.32
1.36
1.45
1.55
1.60
1.65
1.75
1.87
1.99
2.12
2.25
2.39
2.54
2.69
2.86
3.03
3.21
3.30

Watts
1228
1268
1352
1441
1488
1536
1636
1742
1855
1973
2098
2229
2367
2512
2664
2823
2990
3076

1.8
Bhp
2.21
2.26
2.37
2.48
2.54
2.60
2.73
2.86
3.00
3.15
3.31
3.47
3.64

Watts
2061
2109
2209
2315
2370
2427
2545
2670
2800
2938
3082
3233
3391

Rpm
1013
1017
1026
1035
1039
1044
1053
1063
1072
1082
1093

2.0
Bhp
2.46
2.51
2.62
2.74
2.80
2.86
2.99
3.13
3.28
3.43
3.59

Watts
2289
2340
2443
2553
2611
2669
2791
2920
3055
3196
3345

50TFF008 (71/2 TONS) HIGH-STATIC MOTOR (Belt Drive)* (cont)


Airflow
(Cfm)
2250
2300
2400
2500
2550
2600
2700
2800
2900
3000
3100
3200
3300
3400
3500
3600
3700
3750

Rpm
831
836
846
856
862
867
878
889
900
912
923
935
947
960
972
985
997
1004

1.2
Bhp
1.53
1.57
1.67
1.77
1.82
1.87
1.99
2.11
2.23
2.36
2.50
2.65
2.80
2.96
3.13
3.31
3.49
3.59

Watts
1423
1465
1554
1647
1697
1747
1852
1963
2080
2204
2334
2471
2613
2764
2921
3086
3259
3347

Rpm
880
885
895
905
910
915
925
936
946
957
969
980
992
1003
1015
1028

1.4
Bhp
1.74
1.79
1.89
2.00
2.05
2.11
2.23
2.35
2.48
2.62
2.76
2.92
3.07
3.24
3.42
3.60

External Static Pressure (in. wg)


1.6
Watts
Rpm
Bhp
Watts
Rpm
1627
927
1.97
1840
971
1671
931
2.02
1886
975
1764
941
2.13
1982
984
1862
950
2.24
2085
993
1913
955
2.29
2138
998
1966
960
2.35
2193
1003
2076
970
2.47
2307
1012
2192
980
2.60
2427
1022
2314
990
2.74
2554
1032
2442
1001
2.88
2687
1043
2577
1012
3.03
2826
1053
2718
1023
3.19
2973
1064
2867
1034
3.35
3126
1074
3022
1045
3.52
3286

3185
1057
3.70
3454

3355

LEGEND
Bhp
Brake Horsepower Input to Fan
Watts Input Watts to Motor
*Motor drive range: 860 to 1080 rpm. All other rpms require fieldsupplied drive.

NOTES:
1. Boldface indicates field-supplied drive is required.
2. Maximum continuous bhp is 3.70.
3. See page 32 for general fan performance notes.

41

50TFF

2250
2300
2400
2500
2550
2600
2700
2800
2900
3000
3100
3200
3300
3400
3500
3600
3700
3750

Rpm
511
519
534
550
557
565
581
597
613
629
646
662
679
695
712
729
746
754

0.2
Bhp
0.58
0.61
0.68
0.75
0.79
0.83
0.91
1.00
1.09
1.20
1.30
1.42
1.54
1.67
1.81
1.95
2.10
2.18

Performance data 50TFF (cont)


FAN PERFORMANCE VERTICAL DISCHARGE UNITS (cont)
50TFF009 (81/2 TONS) STANDARD MOTOR (Belt Drive)*
Airflow
(Cfm)

50TFF

2550
2600
2700
2800
2900
3000
3100
3200
3300
3400
3500
3600
3700
3750
3800
3900
4000
4100
4200
4250

Rpm
557
565
581
597
613
629
646
662
679
695
712
729
746
754
763

0.2
Bhp
0.79
0.83
0.91
1.00
1.09
1.20
1.30
1.42
1.54
1.67
1.81
1.95
2.10
2.18
2.26

Watts
733
770
848
932
1020
1115
1217
1324
1438
1558
1686
1820
1962
2036
2112

Rpm
631
638
652
667
681
696
711
726
741
756
772
787
803

0.4
Bhp
0.98
1.02
1.11
1.21
1.31
1.42
1.53
1.65
1.78
1.92
2.06
2.21
2.37

External Static Pressure (in. wg)


0.6
Watts
Rpm
Bhp
Watts
Rpm
910
697
1.17
1095
756
950
703
1.22
1138
762
1034
716
1.32
1228
774
1124
729
1.42
1323
786
1220
743
1.53
1425
799
1321
756
1.64
1532
812
1428
770
1.76
1645
825
1542
784
1.89
1765
838
1663
798
2.03
1892
851
1790
812
2.17
2025

1923
827
2.32
2165

2065

2213

0.8
Bhp
1.38
1.43
1.53
1.64
1.75
1.88
2.00
2.14
2.28

Watts
1287
1333
1428
1529
1636
1749
1869
1994
2126

Rpm
811
816
828
839
851
863
875
888

1.0
Bhp
1.60
1.65
1.75
1.87
1.99
2.12
2.25
2.39

Watts
1488
1536
1636
1742
1855
1973
2098
2229

1.8
Bhp

Watts

Rpm

2.0
Bhp

Watts

50TFF009 (81/2 TONS) STANDARD MOTOR (Belt Drive)* (cont)


Airflow
(Cfm)
2550
2600
2700
2800
2900
3000
3100
3200
3300
3400
3500
3600
3700
3750
3800
3900
4000
4100
4200
4250

Rpm
862
867
878
889
900
912

1.2
Bhp
1.82
1.87
1.99
2.11
2.23
2.36

Watts
1697
1747
1852
1963
2080
2204

Rpm
910
915
925
936

1.4
Bhp
2.05
2.11
2.23
2.35

External Static Pressure (in. wg)


1.6
Watts
Rpm
Bhp
Watts
Rpm
1913
955
2.29
2138

1966
960
2.35
2193

2076

2192

LEGEND
Bhp
Brake Horsepower Input to Fan
Watts Input Watts to Motor
*Motor drive range: 685 to 935 rpm. All other rpms require fieldsupplied drive.

42

NOTES:
1. Boldface indicates field-supplied drive is required.
2. Maximum continuous bhp is 2.40.
3. See page 32 for general fan performance notes.

FAN PERFORMANCE VERTICAL DISCHARGE UNITS (cont)


50TFF009 (81/2 TONS) HIGH-STATIC MOTOR (Belt Drive)*
Airflow
(Cfm)

Watts
733
770
848
932
1020
1115
1217
1324
1438
1558
1686
1820
1962
2036
2112
2269
2434
2607
2788
2883

Rpm
631
638
652
667
681
696
711
726
741
756
772
787
803
811
819
835
851
867
883
891

0.4
Bhp
0.98
1.02
1.11
1.21
1.31
1.42
1.53
1.65
1.78
1.92
2.06
2.21
2.37
2.46
2.54
2.72
2.90
3.09
3.29
3.40

External Static Pressure (in. wg)


0.6
Watts
Rpm
Bhp
Watts
Rpm
910
697
1.17
1095
756
950
703
1.22
1138
762
1034
716
1.32
1228
774
1124
729
1.42
1323
786
1220
743
1.53
1425
799
1321
756
1.64
1532
812
1428
770
1.76
1645
825
1542
784
1.89
1765
838
1663
798
2.03
1892
851
1790
812
2.17
2025
865
1923
827
2.32
2165
878
2065
841
2.48
2312
892
2213
856
2.65
2467
906
2290
864
2.73
2548
913
2369
871
2.82
2630
920
2533
886
3.00
2800
934
2705
901
3.19
2978
949
2884
916
3.39
3164
963
3072
932
3.60
3358

3170

0.8
Bhp
1.38
1.43
1.53
1.64
1.75
1.88
2.00
2.14
2.28
2.43
2.59
2.75
2.92
3.01
3.10
3.29
3.49
3.70

Watts
1287
1333
1428
1529
1636
1749
1869
1994
2126
2266
2412
2565
2726
2809
2895
3070
3255
3447

Rpm
811
816
828
839
851
863
875
888
901
913
926
940
953
960
966
980

1.0
Bhp
1.60
1.65
1.75
1.87
1.99
2.12
2.25
2.39
2.54
2.69
2.86
3.03
3.21
3.30
3.39
3.59

Watts
1488
1536
1636
1742
1855
1973
2098
2229
2367
2512
2664
2823
2990
3076
3164
3346

1.8
Bhp
2.54
2.60
2.73
2.86
3.00
3.15
3.31
3.47
3.64

Watts
2370
2427
2545
2670
2800
2938
3082
3233
3391

Rpm
1039
1044
1053
1063
1072
1082
1093

2.0
Bhp
2.80
2.86
2.99
3.13
3.28
3.43
3.59

Watts
2611
2669
2791
2920
3055
3196
3345

50TFF009 (81/2 TONS) HIGH-STATIC MOTOR (Belt Drive)* (cont)


Airflow
(Cfm)
2550
2600
2700
2800
2900
3000
3100
3200
3300
3400
3500
3600
3700
3750
3800
3900
4000
4100
4200
4250

Rpm
862
867
878
889
900
912
923
935
947
960
972
985
997
1004
1010

1.2
Bhp
1.82
1.87
1.99
2.11
2.23
2.36
2.50
2.65
2.80
2.96
3.13
3.31
3.49
3.59
3.69

Watts
1697
1747
1852
1963
2080
2204
2334
2471
2613
2764
2921
3086
3259
3347
3438

Rpm
910
915
925
936
946
957
969
980
992
1003
1015
1028

1.4
Bhp
2.05
2.11
2.23
2.35
2.48
2.62
2.76
2.92
3.07
3.24
3.42
3.60

External Static Pressure (in. wg)


1.6
Watts
Rpm
Bhp
Watts
Rpm
1913
955
2.29
2138
998
1966
960
2.35
2193
1003
2076
970
2.47
2307
1012
2192
980
2.60
2427
1022
2314
990
2.74
2554
1032
2442
1001
2.88
2687
1043
2577
1012
3.03
2826
1053
2718
1023
3.19
2973
1064
2867
1034
3.35
3126
1074
3022
1045
3.52
3286

3185
1057
3.70
3454

3355

LEGEND
Bhp
Brake Horsepower Input to Fan
Watts Input Watts to Motor
*Motor drive range: 860 to 1080 rpm. All other rpms require fieldsupplied drive.

NOTES:
1. Boldface indicates field-supplied drive is required.
2. Maximum continuous bhp is 3.70.
3. See page 32 for general fan performance notes.

43

50TFF

2550
2600
2700
2800
2900
3000
3100
3200
3300
3400
3500
3600
3700
3750
3800
3900
4000
4100
4200
4250

Rpm
557
565
581
597
613
629
646
662
679
695
712
729
746
754
763
780
797
814
831
840

0.2
Bhp
0.79
0.83
0.91
1.00
1.09
1.20
1.30
1.42
1.54
1.67
1.81
1.95
2.10
2.18
2.26
2.43
2.61
2.80
2.99
3.09

Performance data 50TFF (cont)


FAN PERFORMANCE VERTICAL DISCHARGE UNITS (cont)
50TFF012 (10 TONS) STANDARD MOTOR (Belt Drive)*
External Static Pressure (in. wg)
0.6
Watts
Rpm
Bhp
Watts
Rpm
702
668
0.96
846
726
755
678
1.03
903
735
810
689
1.10
963
745
869
699
1.17
1026
755
930
710
1.24
1092
765
995
721
1.32
1162
775
1063
732
1.41
1234
785
1134
743
1.49
1310
796
1209
754
1.58
1390
806
1287
765
1.68
1472
817
1369
777
1.78
1559
828
1454
788
1.88
1649
838
1543
800
1.99
1743
850
1636
812
2.10
1841
861
1734
824
2.21
1943

1835
836
2.33
2049

1940

2049

0.8
Bhp
1.13
1.20
1.27
1.35
1.43
1.51
1.60
1.69
1.79
1.89
1.99
2.10
2.21
2.33

Watts
990
1052
1117
1184
1255
1329
1406
1487
1571
1658
1749
1844
1943
2046

Rpm
779
788
797
806
816
825
835
845
855
865
875
886

1.0
Bhp
1.29
1.37
1.45
1.53
1.62
1.71
1.80
1.90
2.00
2.10
2.21
2.32

Watts
1136
1202
1271
1343
1418
1497
1579
1664
1753
1845
1941
2040

50TFF012 (10 TONS) STANDARD MOTOR (Belt Drive)* (cont)


External Static Pressure (in. wg)
Airflow
1.2
1.4
1.6
(Cfm)
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
3000
829
1.46
1283
876
1.63
1432
920
1.80
1582
963
3100
838
1.54
1353
884
1.72
1506
928
1.89
1661
970
3200
846
1.63
1427
892
1.81
1584
936
1.99
1743
978
3300
855
1.71
1503
901
1.90
1665
944
2.08
1828
985
3400
864
1.80
1583
909
1.99
1749
952
2.18
1917
993
3500
873
1.90
1666
918
2.09
1837
960
2.29
2008

3600
882
2.00
1752
927
2.20
1927
969
2.40
2103

3700
891
2.10
1842
935
2.30
2021

3800
901
2.21
1935

3900
911
2.32
2032

4000

4100

4200

4300

4400

4500

4600

4700

4800

4900

5000

1.8
Bhp
1.98
2.07
2.17
2.27
2.38

Watts
1734
1818
1904
1993
2085

Rpm
1003
1010
1018

2.0
Bhp
2.15
2.25
2.35

Watts
1889
1976
2066

Airflow
(Cfm)

50TFF

3000
3100
3200
3300
3400
3500
3600
3700
3800
3900
4000
4100
4200
4300
4400
4500
4600
4700
4800
4900
5000

Rpm
532
545
557
570
583
596
609
623
636
649
663
676
690
703
717
731
744
758
772
786

0.2
Bhp
0.64
0.69
0.75
0.81
0.88
0.94
1.02
1.09
1.17
1.25
1.34
1.43
1.53
1.63
1.74
1.85
1.96
2.08
2.20
2.33

Watts
559
607
658
712
768
828
891
958
1028
1101
1178
1258
1343
1431
1523
1620
1720
1825
1934
2047

Rpm
604
615
627
638
650
662
673
685
698
710
722
735
747
760
772
785
798
811

0.4
Bhp
0.80
0.86
0.92
0.99
1.06
1.13
1.21
1.29
1.38
1.47
1.56
1.66
1.76
1.86
1.98
2.09
2.21
2.34

LEGEND
Bhp
Brake Horsepower Input to Fan
Watts Input Watts to Motor
*Motor drive range: 685 to 935 rpm. All other rpms require fieldsupplied drive.

44

NOTES:
1. Boldface indicates field-supplied drive is required.
2. Maximum continuous bhp is 2.40.
3. See page 32 for general fan performance notes.

FAN PERFORMANCE VERTICAL DISCHARGE UNITS (cont)


50TFF012 (10 TONS) ALTERNATE MOTOR (Belt Drive)*
0.8
Bhp
1.13
1.20
1.27
1.35
1.43
1.51
1.60
1.69
1.79
1.89
1.99
2.10
2.21
2.33
2.45
2.58
2.71
2.85

Watts
990
1052
1117
1184
1255
1329
1406
1487
1571
1658
1749
1844
1943
2046
2153
2263
2378
2497

Rpm
779
788
797
806
816
825
835
845
855
865
875
886
896
907
917
928

1.0
Bhp
1.29
1.37
1.45
1.53
1.62
1.71
1.80
1.90
2.00
2.10
2.21
2.32
2.44
2.56
2.69
2.82

Watts
1136
1202
1271
1343
1418
1497
1579
1664
1753
1845
1941
2040
2143
2251
2362
2478

50TFF012 (10 TONS) ALTERNATE MOTOR (Belt Drive) (cont)


External Static Pressure (in. wg)
Airflow
1.2
1.4
1.6
(Cfm))
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
3000
829
1.46
1283
876
1.63
1432
920
1.80
1582
963
3100
838
1.54
1353
884
1.72
1506
928
1.89
1661
970
3200
846
1.63
1427
892
1.81
1584
936
1.99
1743
978
3300
855
1.71
1503
901
1.90
1665
944
2.08
1828
985
3400
864
1.80
1583
909
1.99
1749
952
2.18
1917
993
3500
873
1.90
1666
918
2.09
1837
960
2.29
2008
1001
3600
882
2.00
1752
927
2.20
1927
969
2.40
2103
1009
3700
891
2.10
1842
935
2.30
2021
977
2.51
2202
1018
3800
901
2.21
1935
945
2.41
2119
986
2.63
2304
1026
3900
911
2.32
2032
954
2.53
2220
995
2.74
2409

4000
920
2.43
2132
963
2.65
2325
1004
2.87
2518

4100
930
2.55
2237
973
2.77
2433

4200
940
2.67
2345
982
2.90
2546

4300
950
2.80
2456

4400

4500

4600

4700

4800

4900

5000

1.8
Bhp
1.98
2.07
2.17
2.27
2.38
2.49
2.60
2.72
2.84

Watts
1734
1818
1904
1993
2085
2181
2281
2384
2490

Rpm
1003
1010
1018
1025
1033
1040
1048

2.0
Bhp
2.15
2.25
2.35
2.46
2.57
2.68
2.80

Watts
1889
1976
2066
2159
2256
2356
2459

3000
3100
3200
3300
3400
3500
3600
3700
3800
3900
4000
4100
4200
4300
4400
4500
4600
4700
4800
4900
5000

Rpm
532
545
557
570
583
596
609
623
636
649
663
676
690
703
717
731
744
758
772
786
800

0.2
Bhp
0.64
0.69
0.75
0.81
0.88
0.94
1.02
1.09
1.17
1.25
1.34
1.43
1.53
1.63
1.74
1.85
1.96
2.08
2.20
2.33
2.47

Watts
559
607
658
712
768
828
891
958
1028
1101
1178
1258
1343
1431
1523
1620
1720
1825
1934
2047
2165

Rpm
604
615
627
638
650
662
673
685
698
710
722
735
747
760
772
785
798
811
824
837
850

0.4
Bhp
0.80
0.86
0.92
0.99
1.06
1.13
1.21
1.29
1.38
1.47
1.56
1.66
1.76
1.86
1.98
2.09
2.21
2.34
2.47
2.60
2.74

LEGEND
Bhp
Brake Horsepower Input to Fan
Watts Input Watts to Motor
*Motor drive range: 835 to 1085 rpm. All other rpms require fieldsupplied drive.

NOTES:
1. Boldface indicates field-supplied drive is required.
2. Maximum continuous bhp is 2.90.
3. See page 32 for general fan performance notes.

45

50TFF

External Static Pressure (in. wg)


0.6
Watts
Rpm
Bhp
Watts
Rpm
702
668
0.96
846
726
755
678
1.03
903
735
810
689
1.10
963
745
869
699
1.17
1026
755
930
710
1.24
1092
765
995
721
1.32
1162
775
1063
732
1.41
1234
785
1134
743
1.49
1310
796
1209
754
1.58
1390
806
1287
765
1.68
1472
817
1369
777
1.78
1559
828
1454
788
1.88
1649
838
1543
800
1.99
1743
850
1636
812
2.10
1841
861
1734
824
2.21
1943
872
1835
836
2.33
2049
883
1940
848
2.46
2159
895
2049
860
2.59
2273
906
2163
872
2.73
2392

2282
885
2.87
2515

2405

Airflow
(Cfm)

Performance data 50TFF (cont)


FAN PERFORMANCE VERTICAL DISCHARGE UNITS (cont)
50TFF012 (10 TONS) HIGH-STATIC MOTOR (Belt Drive)*
External Static Pressure (in. wg)
0.6
Watts
Rpm
Bhp
Watts
Rpm
702
668
0.96
846
726
755
678
1.03
903
735
810
689
1.10
963
745
869
699
1.17
1026
755
930
710
1.24
1092
765
995
721
1.32
1162
775
1063
732
1.41
1234
785
1134
743
1.49
1310
796
1209
754
1.58
1390
806
1287
765
1.68
1472
817
1369
777
1.78
1559
828
1454
788
1.88
1649
838
1543
800
1.99
1743
850
1636
812
2.10
1841
861
1734
824
2.21
1943
872
1835
836
2.33
2049
883
1940
848
2.46
2159
895
2049
860
2.59
2273
906
2163
872
2.73
2392
918
2282
885
2.87
2515
930
2405
897
3.01
2643
942

0.8
Bhp
1.13
1.20
1.27
1.35
1.43
1.51
1.60
1.69
1.79
1.89
1.99
2.10
2.21
2.33
2.45
2.58
2.71
2.85
2.99
3.13
3.28

Watts
990
1052
1117
1184
1255
1329
1406
1487
1571
1658
1749
1844
1943
2046
2153
2263
2378
2497
2621
2749
2881

Rpm
779
788
797
806
816
825
835
845
855
865
875
886
896
907
917
928
939
950
961
973
984

1.0
Bhp
1.29
1.37
1.45
1.53
1.62
1.71
1.80
1.90
2.00
2.10
2.21
2.32
2.44
2.56
2.69
2.82
2.96
3.10
3.25
3.40
3.55

Watts
1136
1202
1271
1343
1418
1497
1579
1664
1753
1845
1941
2040
2143
2251
2362
2478
2597
2721
2850
2982
3119

50TFF012 (10 TONS) HIGH-STATIC MOTOR (Belt Drive)* (cont)


External Static Pressure (in. wg)
Airflow
1.2
1.4
1.6
(Cfm)
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
3000
829
1.46
1283
876
1.63
1432
920
1.80
1582
963
3100
838
1.54
1353
884
1.72
1506
928
1.89
1661
970
3200
846
1.63
1427
892
1.81
1584
936
1.99
1743
978
3300
855
1.71
1503
901
1.90
1665
944
2.08
1828
985
3400
864
1.80
1583
909
1.99
1749
952
2.18
1917
993
3500
873
1.90
1666
918
2.09
1837
960
2.29
2008
1001
3600
882
2.00
1752
927
2.20
1927
969
2.40
2103
1009
3700
891
2.10
1842
935
2.30
2021
977
2.51
2202
1018
3800
901
2.21
1935
945
2.41
2119
986
2.63
2304
1026
3900
911
2.32
2032
954
2.53
2220
995
2.74
2409
1035
4000
920
2.43
2132
963
2.65
2325
1004
2.87
2518
1043
4100
930
2.55
2237
973
2.77
2433
1013
3.00
2632
1052
4200
940
2.67
2345
982
2.90
2546
1023
3.13
2749
1061
4300
950
2.80
2456
992
3.03
2663
1032
3.27
2870
1070
4400
961
2.93
2572
1002
3.17
2783
1041
3.41
2995
1079
4500
971
3.07
2692
1012
3.31
2908
1051
3.56
3124
1089
4600
982
3.21
2817
1022
3.46
3036
1061
3.71
3257
1098
4700
992
3.36
2945
1032
3.61
3170
1071
3.87
3395
1108
4800
1003
3.51
3078
1043
3.77
3307
1081
4.03
3537
1117
4900
1014
3.66
3216
1053
3.93
3449
1091
4.20
3684
1127
5000
1025
3.83
3357
1063
4.10
3596
1101
4.37
3835
1137

1.8
Bhp
1.98
2.07
2.17
2.27
2.38
2.49
2.60
2.72
2.84
2.96
3.09
3.23
3.36
3.51
3.65
3.81
3.96
4.13
4.29
4.47
4.64

Watts
1734
1818
1904
1993
2085
2181
2281
2384
2490
2600
2713
2831
2952
3078
3207
3341
3479
3621
3768
3919
4075

Rpm
1003
1010
1018
1025
1033
1040
1048
1056
1064
1073
1081
1090
1098
1107
1116
1125
1134
1144
1153
1162
1172

2.0
Bhp
2.15
2.25
2.35
2.46
2.57
2.68
2.80
2.92
3.05
3.18
3.31
3.45
3.60
3.74
3.90
4.05
4.22
4.38
4.56
4.73
4.92

Watts
1889
1976
2066
2159
2256
2356
2459
2567
2677
2791
2909
3031
3157
3287
3420
3559
3701
3847
3999
4154
4315

Airflow
(Cfm)

50TFF

3000
3100
3200
3300
3400
3500
3600
3700
3800
3900
4000
4100
4200
4300
4400
4500
4600
4700
4800
4900
5000

Rpm
532
545
557
570
583
596
609
623
636
649
663
676
690
703
717
731
744
758
772
786
800

0.2
Bhp
0.64
0.69
0.75
0.81
0.88
0.94
1.02
1.09
1.17
1.25
1.34
1.43
1.53
1.63
1.74
1.85
1.96
2.08
2.20
2.33
2.47

Watts
559
607
658
712
768
828
891
958
1028
1101
1178
1258
1343
1431
1523
1620
1720
1825
1934
2047
2165

Rpm
604
615
627
638
650
662
673
685
698
710
722
735
747
760
772
785
798
811
824
837
850

0.4
Bhp
0.80
0.86
0.92
0.99
1.06
1.13
1.21
1.29
1.38
1.47
1.56
1.66
1.76
1.86
1.98
2.09
2.21
2.34
2.47
2.60
2.74

LEGEND
Bhp
Brake Horsepower Input to Fan
Watts Input Watts to Motor
*Motor drive range: 830 to 1130 rpm. All other rpms require fieldsupplied drive.

46

NOTES:
1. Boldface indicates field-supplied drive is required.
2. Maximum continuous bhp is 5.25.
3. See page 32 for general fan performance notes.

FAN PERFORMANCE VERTICAL DISCHARGE UNITS (cont)


50TFF014 (121/2 TONS) STANDARD MOTOR (Belt Drive)*
Airflow
(Cfm)

Watts
1040
1116
1197
1281
1370
1462
1559
1660
1766
1876
1991
2111
2235
2365
2499
2640
2784
2936
3092
3253
3421

Rpm
713
726
739
753
766
780
794
807
821
835
849
863
877
891
906
920
934
949
963

0.4
Bhp
1.31
1.39
1.48
1.58
1.68
1.79
1.89
2.01
2.13
2.25
2.38
2.51
2.65
2.80
2.95
3.10
3.26
3.43
3.60

External Static Pressure (in. wg)


0.6
Watts
Rpm
Bhp
Watts
Rpm
1218
767
1.50
1395
817
1299
779
1.59
1481
828
1385
792
1.69
1572
840
1474
804
1.79
1666
852
1567
817
1.89
1764
864
1665
830
2.00
1866
876
1767
843
2.12
1973
889
1873
856
2.23
2084
901
1984
869
2.36
2200
914
2099
882
2.49
2320
926
2219
895
2.62
2445
939
2344
909
2.76
2575
952
2473
922
2.91
2709
965
2608
936
3.06
2849
978
2747
949
3.21
2994
991
2892
963
3.37
3143
1004
3042
977
3.54
3298

3198

3359

0.8
Bhp
1.69
1.78
1.88
1.99
2.10
2.22
2.34
2.46
2.59
2.72
2.86
3.01
3.16
3.31
3.47
3.64

Watts
1571
1662
1758
1857
1960
2067
2179
2295
2415
2541
2670
2805
2944
3089
3238
3393

Rpm
863
874
886
897
909
920
932
944
956
968
980
993
1005
1018

1.0
Bhp
1.87
1.98
2.08
2.20
2.31
2.43
2.56
2.69
2.82
2.96
3.10
3.25
3.41
3.57

Watts
1748
1844
1943
2048
2155
2268
2384
2505
2630
2760
2895
3034
3178
3328

1.8
Bhp
2.63
2.76
2.88
3.02
3.15
3.29
3.44
3.59

Watts
2457
2571
2690
2812
2939
3070
3205
3345

Rpm
1063
1073
1082
1092
1102
1112
1122

2.0
Bhp
2.83
2.95
3.09
3.22
3.36
3.51
3.66

Watts
2636
2755
2877
3004
3136
3271
3411

50TFF014 (121/2 TONS) STANDARD MOTOR (Belt Drive)* (cont)


Airflow
(Cfm)
3700
3800
3900
4000
4100
4200
4300
4400
4500
4600
4700
4800
4900
5000
5100
5200
5300
5400
5500
5600
5700
5800
5900
6000
6100
6200
6300

Rpm
907
918
929
940
951
962
973
985
996
1008
1020
1032
1044

1.2
Bhp
2.06
2.17
2.28
2.40
2.52
2.65
2.78
2.91
3.05
3.20
3.34
3.50
3.66

Watts
1924
2025
2130
2238
2351
2468
2589
2715
2845
2979
3119
3263
3413

Rpm
949
959
970
980
991
1002
1013
1024
1035
1046
1058

1.4
Bhp
2.25
2.37
2.48
2.61
2.73
2.86
3.00
3.14
3.28
3.43
3.58

External Static Pressure (in. wg)


1.6
Watts
Rpm
Bhp
Watts
Rpm
2101
989
2.44
2279
1027
2207
999
2.56
2389
1036
2316
1009
2.68
2502
1046
2429
1019
2.81
2620
1056
2547
1029
2.94
2743
1066
2668
1040
3.08
2869
1076
2794
1050
3.22
2999
1087
2924
1061
3.36
3134
1097
3059
1072
3.51
3274

3199
1083
3.67
3418

3343

LEGEND
Bhp
Brake Horsepower Input to Fan
Watts Input Watts to Motor
*Motor drive range: 860 to 1080 rpm. All other rpms require fieldsupplied drive.

NOTES:
1. Boldface indicates field-supplied drive is required.
2. Maximum continuous bhp is 3.70.
3. See page 32 for general fan performance notes.

47

50TFF

3700
3800
3900
4000
4100
4200
4300
4400
4500
4600
4700
4800
4900
5000
5100
5200
5300
5400
5500
5600
5700
5800
5900
6000
6100
6200
6300

Rpm
654
668
683
697
712
726
741
755
770
785
800
815
829
844
859
874
889
904
920
935
950

0.2
Bhp
1.11
1.20
1.28
1.37
1.47
1.57
1.67
1.78
1.89
2.01
2.14
2.26
2.40
2.54
2.68
2.83
2.99
3.15
3.32
3.49
3.67

Performance data 50TFF (cont)


FAN PERFORMANCE VERTICAL DISCHARGE UNITS (cont)
50TFF014 (121/2 TONS) ALTERNATE MOTOR (Belt Drive)*
Airflow
(Cfm)

50TFF

3700
3800
3900
4000
4100
4200
4300
4400
4500
4600
4700
4800
4900
5000
5100
5200
5300
5400
5500
5600
5700
5800
5900
6000
6100
6200
6300

Rpm
654
668
683
697
712
726
741
755
770
785
800
815
829
844
859
874
889
904
920
935
950
965
980
995
1011
1026
1041

0.2
Bhp
1.11
1.20
1.28
1.37
1.47
1.57
1.67
1.78
1.89
2.01
2.14
2.26
2.40
2.54
2.68
2.83
2.99
3.15
3.32
3.49
3.67
3.85
4.05
4.24
4.45
4.66
4.88

Watts
1040
1116
1197
1281
1370
1462
1559
1660
1766
1876
1991
2111
2235
2365
2499
2640
2784
2936
3092
3253
3421
3594
3773
3958
4149
4347
4550

Rpm
713
726
739
753
766
780
794
807
821
835
849
863
877
891
906
920
934
949
963
977
992
1006
1021
1036
1050
1065
1080

0.4
Bhp
1.31
1.39
1.48
1.58
1.68
1.79
1.89
2.01
2.13
2.25
2.38
2.51
2.65
2.80
2.95
3.10
3.26
3.43
3.60
3.78
3.97
4.16
4.35
4.56
4.77
4.99
5.21

External Static Pressure (in. wg)


0.6
Watts
Rpm
Bhp
Watts
Rpm
1218
767
1.50
1395
817
1299
779
1.59
1481
828
1385
792
1.69
1572
840
1474
804
1.79
1666
852
1567
817
1.89
1764
864
1665
830
2.00
1866
876
1767
843
2.12
1973
889
1873
856
2.23
2084
901
1984
869
2.36
2200
914
2099
882
2.49
2320
926
2219
895
2.62
2445
939
2344
909
2.76
2575
952
2473
922
2.91
2709
965
2608
936
3.06
2849
978
2747
949
3.21
2994
991
2892
963
3.37
3143
1004
3042
977
3.54
3298
1017
3198
990
3.71
3459
1030
3359
1004
3.89
3625
1044
3525
1018
4.07
3796
1057
3698
1032
4.26
3974
1070
3876
1046
4.46
4157
1084
4060
1060
4.66
4346
1098
4250
1074
4.87
4541
1111
4446
1088
5.09
4742

4649

4857

0.8
Bhp
1.69
1.78
1.88
1.99
2.10
2.22
2.34
2.46
2.59
2.72
2.86
3.01
3.16
3.31
3.47
3.64
3.81
3.99
4.17
4.36
4.56
4.76
4.97
5.18

Watts
1571
1662
1758
1857
1960
2067
2179
2295
2415
2541
2670
2805
2944
3089
3238
3393
3553
3719
3890
4066
4249
4436
4630
4831

Rpm
863
874
886
897
909
920
932
944
956
968
980
993
1005
1018
1030
1043
1056
1068
1081
1094
1107
1120

1.0
Bhp
1.87
1.98
2.08
2.20
2.31
2.43
2.56
2.69
2.82
2.96
3.10
3.25
3.41
3.57
3.73
3.91
4.08
4.27
4.45
4.65
4.85
5.06

Watts
1748
1844
1943
2048
2155
2268
2384
2505
2630
2760
2895
3034
3178
3328
3483
3642
3807
3977
4153
4335
4522
4715

1.8
Bhp
2.63
2.76
2.88
3.02
3.15
3.29
3.44
3.59
3.74
3.90
4.07
4.24
4.41
4.59
4.78
4.97
5.17

Watts
2457
2571
2690
2812
2939
3070
3205
3345
3489
3638
3792
3950
4113
4282
4456
4634
4819

Rpm
1063
1073
1082
1092
1102
1112
1122
1132
1142
1152
1163
1174
1184
1195
1206
1217

2.0
Bhp
2.83
2.95
3.09
3.22
3.36
3.51
3.66
3.81
3.97
4.14
4.31
4.48
4.66
4.85
5.04
5.24

Watts
2636
2755
2877
3004
3136
3271
3411
3555
3704
3857
4016
4179
4347
4520
4699
4882

50TFF014 (121/2 TONS) ALTERNATE MOTOR (Belt Drive)*


Airflow
(Cfm)
3700
3800
3900
4000
4100
4200
4300
4400
4500
4600
4700
4800
4900
5000
5100
5200
5300
5400
5500
5600
5700
5800
5900
6000
6100
6200
6300

Rpm
907
918
929
940
951
962
973
985
996
1008
1020
1032
1044
1056
1068
1080
1093
1105
1118
1130
1143

1.2
Bhp
2.06
2.17
2.28
2.40
2.52
2.65
2.78
2.91
3.05
3.20
3.34
3.50
3.66
3.82
4.00
4.17
4.35
4.54
4.74
4.94
5.14

Watts
1924
2025
2130
2238
2351
2468
2589
2715
2845
2979
3119
3263
3413
3566
3726
3891
4060
4236
4417
4603
4795

Rpm
949
959
970
980
991
1002
1013
1024
1035
1046
1058
1069
1081
1093
1104
1116
1128
1140
1152
1165

1.4
Bhp
2.25
2.37
2.48
2.61
2.73
2.86
3.00
3.14
3.28
3.43
3.58
3.74
3.91
4.08
4.26
4.44
4.63
4.82
5.02
5.22

External Static Pressure (in. wg)


1.6
Watts
Rpm
Bhp
Watts
Rpm
2101
989
2.44
2279
1027
2207
999
2.56
2389
1036
2316
1009
2.68
2502
1046
2429
1019
2.81
2620
1056
2547
1029
2.94
2743
1066
2668
1040
3.08
2869
1076
2794
1050
3.22
2999
1087
2924
1061
3.36
3134
1097
3059
1072
3.51
3274
1108
3199
1083
3.67
3418
1118
3343
1094
3.83
3567
1129
3492
1105
3.99
3721
1140
3646
1117
4.16
3880
1151
3805
1128
4.34
4044
1162
3969
1139
4.52
4212
1173
4139
1151
4.70
4386
1185
4314
1163
4.90
4566
1196
4494
1174
5.10
4751

4679

4870

LEGEND
Bhp
Brake Horsepower Input to Fan
Watts Input Watts to Motor
*Motor drive range: 830 to 1130 rpm. All other rpms require fieldsupplied drive.

48

NOTES:
1. Boldface indicates field-supplied drive is required.
2. Maximum continuous bhp is 5.25.
3. See page 32 for general fan performance notes.

FAN PERFORMANCE HORIZONTAL DISCHARGE UNITS

LEGEND
Bhp
Brake Horsepower Input to Fan
ESP External Static Pressure (in. wg)
Watts Input Watts to Motor

High Speed
ESP
0.73
0.70
0.64
0.56
0.53
0.47
0.43

208 v
Bhp
0.26
0.27
0.28
0.29
0.31
0.32
0.33

Watts
307
321
335
349
364
378
392

ESP
0.76
0.71
0.65
0.59
0.54

230, 460, 575 v


Bhp
Watts
0.31
363
0.32
374
0.33
385
0.34
397
0.34
408

See general fan performance notes on page 32.

50TFF004 (3 TONS) ALTERNATE MOTOR (Belt Drive)*


External Static Pressure (in. wg)
0.6
Watts
Rpm
Bhp
Watts
Rpm
221
856
0.31
304
952
261
884
0.35
351
978
307
912
0.41
404
1005
359
941
0.47
464
1033
417
971
0.53
530
1062
483
1002
0.61
603
1091
556
1033
0.69
685
1121

0.8
Bhp
0.39
0.45
0.51
0.57
0.65
0.73
0.82

Watts
393
446
506
572
645
726
815

Rpm
1037
1062
1089
1116
1143
1172
1201

1.0
Bhp
0.49
0.55
0.61
0.69
0.77
0.86
0.95

Watts
485
545
611
683
764
851
947

50TFF004 (3 TONS) ALTERNATE MOTOR (Belt Drive)* (cont)


External Static Pressure (in. wg)
Airflow
1.2
1.4
1.6
(Cfm)
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
900
1114
0.59
582
1186
0.69
684
1253
0.79
789
1316
1000
1139
0.65
648
1210
0.76
754
1277
0.87
865
1340
1100
1165
0.72
720
1236
0.84
832
1302
0.95
948
1364
1200
1191
0.80
799
1261
0.92
917
1327
1.04
1039
1389
1300
1218
0.89
885
1288
1.02
1010
1353
1.14
1138

1400
1246
0.99
980
1315
1.12
1111

1500
1274
1.09
1083

1.8
Bhp
0.90
0.98
1.07
1.17

Watts
898
979
1068
1165

Rpm
1375
1399
1423

2.0
Bhp
1.02
1.10
1.20

Watts
1010
1097
1191

Airflow
(Cfm)
900
1000
1100
1200
1300
1400
1500

Rpm
607
640
674
708
743
780
816

0.2
Bhp
0.14
0.18
0.21
0.26
0.31
0.37
0.43

Watts
142
174
212
256
307
364
428

Rpm
745
775
805
836
868
900
934

0.4
Bhp
0.22
0.26
0.31
0.36
0.42
0.49
0.56

LEGEND
Bhp
Brake Horsepower Input to Fan
Watts Input Watts to Motor
*Motor drive range: 760 to 1000 rpm. All other rpms require fieldsupplied drive.

NOTES:
1. Boldface indicates field-supplied drive is required.
2. Maximum continuous bhp is 1.20.
3. See page 32 for general fan performance notes.

49

50TFF

50TFF004 (3 TONS) STANDARD MOTOR (Direct Drive)


Low Speed
Airflow
208 v
230, 460, 575 v
(Cfm)
ESP
Bhp
Watts
ESP
Bhp
Watts
900
0.72
0.21
253
0.75
0.23
277
1000
0.67
0.23
270
0.69
0.25
292
1100
0.61
0.24
287
0.63
0.26
307
1200
0.57
0.26
304
0.58
0.27
323
1300
0.51
0.27
321
0.53
0.29
338
1400
0.44
0.29
338
0.46
0.30
354
1500
0.39
0.30
355
0.41
0.31
369

Performance data 50TFF (cont)


FAN PERFORMANCE HORIZONTAL DISCHARGE UNITS (cont)
50TFF004 (3 TONS) HIGH-STATIC MOTOR (Belt Drive)*
External Static Pressure (in. wg)
0.6
Watts
Rpm
Bhp
Watts
Rpm
221
856
0.31
304
952
261
884
0.35
351
978
307
912
0.41
404
1005
359
941
0.47
464
1033
417
971
0.53
530
1062
483
1002
0.61
603
1091
556
1033
0.69
685
1121

0.8
Bhp
0.39
0.45
0.51
0.57
0.65
0.73
0.82

Watts
393
446
506
572
645
726
815

Rpm
1037
1062
1089
1116
1143
1172
1201

1.0
Bhp
0.49
0.55
0.61
0.69
0.77
0.86
0.95

Watts
485
545
611
683
764
851
947

50TFF004 (3 TONS) HIGH-STATIC MOTOR (Belt Drive)* (cont)


External Static Pressure (in. wg)
Airflow
1.2
1.4
1.6
(Cfm)
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
900
1114
0.59
582
1186
0.69
684
1253
0.79
789
1316
1000
1139
0.65
648
1210
0.76
754
1277
0.87
865
1340
1100
1165
0.72
720
1236
0.84
832
1302
0.95
948
1364
1200
1191
0.80
799
1261
0.92
917
1327
1.04
1039
1389
1300
1218
0.89
885
1288
1.02
1010
1353
1.14
1138
1414
1400
1246
0.99
980
1315
1.12
1111
1379
1.25
1246
1440
1500
1274
1.09
1083
1342
1.23
1221
1406
1.37
1362
1467

1.8
Bhp
0.90
0.98
1.07
1.17
1.28
1.39
1.51

Watts
898
979
1068
1165
1270
1383
1505

Rpm
1375
1399
1423
1448
1473
1499
1525

2.0
Bhp
1.02
1.10
1.20
1.30
1.41
1.53
1.66

Watts
1010
1097
1191
1293
1404
1523
1652

Airflow
(Cfm)

50TFF

900
1000
1100
1200
1300
1400
1500

Rpm
607
640
674
708
743
780
816

0.2
Bhp
0.14
0.18
0.21
0.26
0.31
0.37
0.43

Watts
142
174
212
256
307
364
428

Rpm
745
775
805
836
868
900
934

0.4
Bhp
0.22
0.26
0.31
0.36
0.42
0.49
0.56

LEGEND
Bhp
Brake Horsepower Input to Fan
Watts Input Watts to Motor
*Motor drive range: 1075 to 1455 rpm. All other rpms require fieldsupplied drive.

NOTES:
1. Boldface indicates field-supplied drive is required.
2. Maximum continuous bhp is 2.40.
3. See page 32 for general fan performance notes.

50TFF005 (4 TONS) STANDARD MOTOR (Direct Drive)


Low Speed
Airflow
208 v
230, 460, 575 v
(Cfm)
ESP
Bhp
Watts
ESP
Bhp
Watts
1200
0.93
0.41
458
0.97
0.45
506
1300
0.86
0.42
471
0.90
0.46
521
1400
0.78
0.45
503
0.84
0.49
556
1500
0.73
0.47
536
0.76
0.52
593
1600
0.67
0.49
557
0.70
0.54
616
1700
0.60
0.52
584
0.63
0.57
646
1800
0.51
0.54
610
0.54
0.60
674
1900
0.40
0.56
629
0.45
0.62
696
2000
0.32
0.58
661
0.33
0.65
731
LEGEND
Bhp
Brake Horsepower Input to Fan
ESP External Static Pressure (in. wg)
Watts Input Watts to Motor
See general fan performance notes on page 32.

50

High Speed
ESP
1.04
0.96
0.90
0.83
0.75
0.67
0.62
0.54
0.47

208 v
Bhp
0.51
0.52
0.54
0.56
0.58
0.60
0.62
0.64
0.66

Watts
572
589
616
631
654
678
698
720
744

ESP
1.09
1.02
0.96
0.89
0.82
0.74
0.69
0.62
0.54

230, 460, 575 v


Bhp
Watts
0.56
632
0.58
651
0.60
681
0.62
698
0.64
723
0.66
750
0.68
772
0.70
796
0.73
823

FAN PERFORMANCE HORIZONTAL DISCHARGE UNITS (cont)


50TFF005 (4 TONS) ALTERNATE MOTOR (Belt Drive)*
0.8
Bhp
0.58
0.65
0.72
0.80
0.89
0.98
1.08
1.19

Watts
579
645
717
796
881
974
1075
1184

Rpm
1020
1045
1071
1097
1124
1151

1.0
Bhp
0.71
0.78
0.86
0.95
1.04
1.14

Watts
705
777
857
942
1035
1136

50TFF005 (4 TONS) ALTERNATE MOTOR (Belt Drive)* (cont)


External Static Pressure (in. wg)
Airflow
1.2
1.4
1.6
(Cfm)
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
1200
1089
0.84
835
1153
0.98
971
1212
1.12
1111

1300
1114
0.92
915
1177
1.06
1056

1400
1139
1.01
1000
1202
1.15
1149

1500
1164
1.10
1093

1600
1190
1.20
1193

1700

1800

1900

2000

1.8
Bhp

Watts

Rpm

2.0
Bhp

Watts

1200
1300
1400
1500
1600
1700
1800
1900
2000

Rpm
643
674
706
738
771
804
837
871
906

0.2
Bhp
0.23
0.28
0.33
0.38
0.44
0.51
0.59
0.67
0.76

Watts
233
276
324
379
440
507
582
665
756

Rpm
762
791
820
849
879
910
941
972
1004

0.4
Bhp
0.35
0.40
0.45
0.52
0.59
0.66
0.75
0.84
0.94

LEGEND
Bhp
Brake Horsepower Input to Fan
Watts Input Watts to Motor
*Motor drive range: 835 to 1185 rpm. All other rpms require fieldsupplied drive.

NOTES:
1. Boldface indicates field-supplied drive is required.
2. Maximum continuous bhp is 1.20.
3. See page 32 for general fan performance notes.

50TFF005 (4 TONS) HIGH-STATIC MOTOR (Belt Drive)*


External Static Pressure (in. wg)
0.6
Watts
Rpm
Bhp
Watts
Rpm
344
860
0.46
459
944
395
887
0.52
517
970
451
914
0.59
582
997
515
942
0.66
653
1024
584
971
0.74
731
1051
661
1000
0.82
816
1079
745
1029
0.91
909
1107
837
1059
1.02
1010
1136
938
1089
1.12
1119
1165

0.8
Bhp
0.58
0.65
0.72
0.80
0.89
0.98
1.08
1.19
1.31

Watts
579
645
717
796
881
974
1075
1184
1301

Rpm
1020
1045
1071
1097
1124
1151
1178
1206
1234

1.0
Bhp
0.71
0.78
0.86
0.95
1.04
1.14
1.25
1.37
1.49

Watts
705
777
857
942
1035
1136
1244
1361
1486

50TFF005 (4 TONS) HIGH-STATIC MOTOR (Belt Drive)* (cont)


External Static Pressure (in. wg)
Airflow
1.2
1.4
1.6
(Cfm)
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
1200
1089
0.84
835
1153
0.98
971
1212
1.12
1111
1269
1300
1114
0.92
915
1177
1.06
1056
1236
1.21
1202
1292
1400
1139
1.01
1000
1202
1.15
1149
1261
1.31
1301
1316
1500
1164
1.10
1093
1227
1.25
1248
1285
1.41
1407
1341
1600
1190
1.20
1193
1252
1.36
1355
1311
1.53
1520
1366
1700
1217
1.31
1301
1278
1.48
1470
1336
1.65
1642
1391
1800
1244
1.42
1417
1305
1.60
1593
1362
1.78
1772
1416
1900
1271
1.55
1541
1331
1.73
1724
1388
1.92
1911
1442
2000
1298
1.68
1674
1358
1.87
1865
1415
2.07
2059
1468

1.8
Bhp
1.26
1.36
1.47
1.58
1.70
1.83
1.97
2.11
2.27

Watts
1256
1353
1457
1570
1690
1818
1955
2101
2256

Rpm
1322
1346
1369
1394
1418
1443
1468
1494

2.0
Bhp
1.41
1.52
1.63
1.75
1.87
2.01
2.15
2.31

Watts
1404
1508
1618
1736
1863
1998
2141
2294

Airflow
(Cfm)
1200
1300
1400
1500
1600
1700
1800
1900
2000

Rpm
643
674
706
738
771
804
837
871
906

0.2
Bhp
0.23
0.28
0.33
0.38
0.44
0.51
0.59
0.67
0.76

Watts
233
276
324
379
440
507
582
665
756

Rpm
762
791
820
849
879
910
941
972
1004

0.4
Bhp
0.35
0.40
0.45
0.52
0.59
0.66
0.75
0.84
0.94

LEGEND
Bhp
Brake Horsepower Input to Fan
Watts Input Watts to Motor
*Motor drive range: 1075 to 1455 rpm. All other rpms require fieldsupplied drive.

NOTES:
1. Boldface indicates field-supplied drive is required.
2. Maximum continuous bhp is 2.40.
3. See page 32 for general fan performance notes.

51

50TFF

External Static Pressure (in. wg)


0.6
Watts
Rpm
Bhp
Watts
Rpm
344
860
0.46
459
944
395
887
0.52
517
970
451
914
0.59
582
997
515
942
0.66
653
1024
584
971
0.74
731
1051
661
1000
0.82
816
1079
745
1029
0.91
909
1107
837
1059
1.02
1010
1136
938
1089
1.12
1119

Airflow
(Cfm)

Performance data 50TM (cont)


FAN PERFORMANCE HORIZONTAL DISCHARGE UNITS (cont)
50TFF006 (5 TONS) ALTERNATE MOTOR (Belt Drive)*
External Static Pressure (in. wg)
0.6
Watts
Rpm
Bhp
Watts
Rpm
454
977
0.65
579
1061
517
1007
0.73
646
1089
586
1038
0.81
721
1118
662
1069
0.90
802
1148
747
1102
1.00
892
1179
839
1135
1.11
990
1210
940
1169
1.23
1096
1242
1050
1203
1.36
1211
1274
1169
1238
1.50
1336
1308
1298
1273
1.66
1471
1341
1437
1309
1.82
1616
1375

0.8
Bhp
0.80
0.89
0.97
1.07
1.18
1.29
1.42
1.55
1.70
1.86
2.03

Watts
715
786
865
951
1046
1149
1260
1381
1511
1651
1801

Rpm
1138
1165
1192
1221
1250
1280
1310
1341
1373
1405
1438

1.0
Bhp
0.97
1.05
1.15
1.25
1.36
1.48
1.61
1.75
1.91
2.07
2.24

Watts
860
935
1018
1109
1208
1316
1432
1557
1693
1838
1994

50TFF006 (5 TONS) ALTERNATE MOTOR (Belt Drive)* (cont)


External Static Pressure (in. wg)
Airflow
1.2
1.4
1.6
(Cfm)
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
1500
1210
1.14
1014
1278
1.33
1178
1342
1.52
1350
1403
1600
1236
1.23
1094
1302
1.42
1261
1365
1.62
1436
1425
1700
1262
1.33
1181
1328
1.52
1351
1390
1.72
1530
1449
1800
1289
1.44
1276
1354
1.63
1450
1415
1.84
1632
1473
1900
1317
1.55
1379
1380
1.75
1557
1441
1.96
1743
1498
2000
1345
1.68
1491
1408
1.88
1673
1467
2.10
1863
1524
2100
1375
1.81
1611
1436
2.03
1798
1494
2.24
1993

2200
1405
1.96
1742
1465
2.18
1933
1522
2.40
2132

2300
1435
2.12
1882
1494
2.34
2078

2400
1466
2.29
2032

2500

1.8
Bhp
1.72
1.82
1.93
2.05
2.18
2.32

Watts
1530
1618
1716
1822
1937
2060

Rpm
1461
1483
1505
1529

2.0
Bhp
1.93
2.04
2.15
2.27

Watts
1717
1809
1910
2019

Airflow
(Cfm)

50TFF

1500
1600
1700
1800
1900
2000
2100
2200
2300
2400
2500

Rpm
776
813
851
888
927
965
1004
1044
1084
1123
1164

0.2
Bhp
0.38
0.45
0.52
0.60
0.69
0.78
0.89
1.01
1.14
1.27
1.42

Watts
340
397
461
532
610
697
792
896
1009
1132
1265

Rpm
883
916
949
984
1019
1054
1090
1127
1164
1201
1239

0.4
Bhp
0.51
0.58
0.66
0.75
0.84
0.94
1.06
1.18
1.32
1.46
1.62

LEGEND
Bhp
Brake Horsepower Input to Fan
Watts Input Watts to Motor
*Motor drive range: 900 to 1300 rpm. All other rpms require fieldsupplied drive.

NOTES:
1. Boldface indicates field-supplied drive is required.
2. Maximum continuous bhp is 1.30 for single-phase units and 2.40 for
three-phase units.
3. See page 32 for general fan performance notes.

50TFF006 (5 TONS) HIGH-STATIC MOTOR (Belt Drive)*


External Static Pressure (in. wg)
0.6
Watts
Rpm
Bhp
Watts
Rpm
454
977
0.65
579
1061
517
1007
0.73
646
1089
586
1038
0.81
721
1118
662
1069
0.90
802
1148
747
1102
1.00
892
1179
839
1135
1.11
990
1210
940
1169
1.23
1096
1242
1050
1203
1.36
1211
1274
1169
1238
1.50
1336
1308
1298
1273
1.66
1471
1341
1437
1309
1.82
1616
1375

0.8
Bhp
0.80
0.89
0.97
1.07
1.18
1.29
1.42
1.55
1.70
1.86
2.03

Watts
715
786
865
951
1046
1149
1260
1381
1511
1651
1801

Rpm
1138
1165
1192
1221
1250
1280
1310
1341
1373
1405
1438

1.0
Bhp
0.97
1.05
1.15
1.25
1.36
1.48
1.61
1.75
1.91
2.07
2.24

Watts
860
935
1018
1109
1208
1316
1432
1557
1693
1838
1994

50TFF006 (5 TONS) HIGH-STATIC MOTOR (Belt Drive)* (cont)


External Static Pressure (in. wg)
Airflow
1.2
1.4
1.6
(Cfm)
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
1500
1210
1.14
1014
1278
1.33
1178
1342
1.52
1350
1403
1600
1236
1.23
1094
1302
1.42
1261
1365
1.62
1436
1425
1700
1262
1.33
1181
1328
1.52
1351
1390
1.72
1530
1449
1800
1289
1.44
1276
1354
1.63
1450
1415
1.84
1632
1473
1900
1317
1.55
1379
1380
1.75
1557
1441
1.96
1743
1498
2000
1345
1.68
1491
1408
1.88
1673
1467
2.10
1863
1524
2100
1375
1.81
1611
1436
2.03
1798
1494
2.24
1993
1550
2200
1405
1.96
1742
1465
2.18
1933
1522
2.40
2132
1578
2300
1435
2.12
1882
1494
2.34
2078
1551
2.57
2280
1605
2400
1466
2.29
2032
1524
2.51
2232
1580
2.75
2440

2500
1498
2.47
2193
1555
2.70
2398

1.8
Bhp
1.72
1.82
1.93
2.05
2.18
2.32
2.47
2.63
2.80

Watts
1530
1618
1716
1822
1937
2060
2194
2337
2490

Rpm
1461
1483
1505
1529
1553
1579
1604
1631

2.0
Bhp
1.93
2.04
2.15
2.27
2.41
2.55
2.70
2.87

Watts
1717
1809
1910
2019
2137
2264
2401
2548

Airflow
(Cfm)
1500
1600
1700
1800
1900
2000
2100
2200
2300
2400
2500

Rpm
776
813
851
888
927
965
1004
1044
1084
1123
1164

0.2
Bhp
0.38
0.45
0.52
0.60
0.69
0.78
0.89
1.01
1.14
1.27
1.42

Watts
340
397
461
532
610
697
792
896
1009
1132
1265

Rpm
883
916
949
984
1019
1054
1090
1127
1164
1201
1239

0.4
Bhp
0.51
0.58
0.66
0.75
0.84
0.94
1.06
1.18
1.32
1.46
1.62

LEGEND
Bhp
Brake Horsepower Input to Fan
Watts Input Watts to Motor
*Motor drive range: 1300 to 1685 rpm. All other rpms require fieldsupplied drive.

52

NOTES:
1. Boldface indicates field-supplied drive is required.
2. Maximum continuous bhp is 2.90.
3. See page 32 for general fan performance notes.

FAN PERFORMANCE HORIZONTAL DISCHARGE UNITS (cont)


50TFF007 (6 TONS) STANDARD MOTOR (Belt Drive)*
Airflow
(Cfm)

Watts
458
525
599
680
769
865
970
1084
1206
1338
1480
1632
1794

Rpm
924
955
986
1017
1050
1082
1115
1149
1183
1217
1251
1286
1321

0.4
Bhp
0.65
0.73
0.82
0.92
1.02
1.14
1.26
1.39
1.54
1.69
1.86
2.04
2.22

External Static Pressure (in. wg)


0.6
Watts
Rpm
Bhp
Watts
579
1015
0.80
712
650
1043
0.89
787
729
1072
0.98
870
815
1101
1.08
960
909
1131
1.19
1059
1010
1161
1.31
1165
1120
1192
1.44
1279
1239
1223
1.58
1403
1367
1255
1.73
1535
1503
1287
1.89
1677
1650
1320
2.06
1829
1807
1353
2.24
1991
1975

Rpm
1099
1125
1151
1178
1206
1235
1264
1293
1323
1354
1385

0.8
Bhp
0.96
1.05
1.15
1.26
1.37
1.50
1.63
1.77
1.93
2.09
2.27

Watts
857
936
1022
1116
1218
1329
1448
1576
1713
1859
2015

Rpm
1177
1201
1226
1251
1277
1304
1332
1360
1389
1418

1.0
Bhp
1.14
1.23
1.33
1.44
1.56
1.69
1.83
1.98
2.14
2.31

Watts
1013
1096
1185
1283
1389
1503
1625
1757
1898
2049

External Static Pressure (in. wg)


1.6
Watts
Rpm
Bhp
Watts
1360
1385
1.74
1549
1447
1405
1.84
1638
1542
1427
1.95
1736
1646
1448
2.07
1842
1758
1471
2.20
1956
1878
1494
2.34
2080
2008

Rpm
1448
1467
1488
1508

1.8
Bhp
1.97
2.07
2.18
2.30

Watts
1748
1839
1939
2047

Rpm
1508
1527

2.0
Bhp
2.20
2.31

Watts
1957
2050

1.0
Bhp
1.14
1.23
1.33
1.44
1.56
1.69
1.83
1.98
2.14
2.31
2.49
2.68
2.89

Watts
1013
1096
1185
1283
1389
1503
1625
1757
1898
2049
2210
2381
2563

Bhp
2.20
2.31
2.42
2.55
2.68
2.83

Watts
1957
2050
2151
2262
2380
2509

50TFF007 (6 TONS) STANDARD MOTOR (Belt Drive)* (cont)


Airflow
(Cfm)
1800
1900
2000
2100
2200
2300
2400
2500
2600
2700
2800
2900
3000
Bhp
Watts

Rpm
1250
1273
1296
1320
1345
1371
1397
1424
1451

1.2
Bhp
1.33
1.43
1.53
1.64
1.77
1.90
2.04
2.19
2.36

Watts
1181
1266
1359
1459
1568
1686
1812
1948
2093

Rpm
1319
1341
1363
1386
1409
1434
1459

1.4
Bhp
1.53
1.63
1.74
1.85
1.98
2.11
2.26

LEGEND
Brake Horsepower Input to Fan
Input Watts to Motor

*Motor drive range: 1070 to 1460 rpm. All other rpms require field-supplied drive.

NOTES:
1. Boldface indicates field-supplied drive is required.
2. Maximum continuous bhp is 2.40.
3. See page 32 for general fan performance notes.

50TFF007 (6 TONS) HIGH-STATIC MOTOR (Belt Drive)*


Airflow
(Cfm)
1800
1900
2000
2100
2200
2300
2400
2500
2600
2700
2800
2900
3000

Rpm
823
857
892
927
962
997
1033
1069
1106
1142
1179
1216
1253

0.2
Bhp
0.52
0.59
0.67
0.77
0.87
0.97
1.09
1.22
1.36
1.51
1.67
1.84
2.02

Watts
458
525
599
680
769
865
970
1084
1206
1338
1480
1632
1794

Rpm
924
955
986
1017
1050
1082
1115
1149
1183
1217
1251
1286
1321

0.4
Bhp
0.65
0.73
0.82
0.92
1.02
1.14
1.26
1.39
1.54
1.69
1.86
2.04
2.22

External Static Pressure (in. wg)


0.6
Watts
Rpm
Bhp
Watts
579
1015
0.80
712
650
1043
0.89
787
729
1072
0.98
870
815
1101
1.08
960
909
1131
1.19
1059
1010
1161
1.31
1165
1120
1192
1.44
1279
1239
1223
1.58
1403
1367
1255
1.73
1535
1503
1287
1.89
1677
1650
1320
2.06
1829
1807
1353
2.24
1991
1975
1386
2.44
2163

Rpm
1099
1125
1151
1178
1206
1235
1264
1293
1323
1354
1385
1416
1448

0.8
Bhp
0.96
1.05
1.15
1.26
1.37
1.50
1.63
1.77
1.93
2.09
2.27
2.46
2.66

Watts
857
936
1022
1116
1218
1329
1448
1576
1713
1859
2015
2182
2359

Rpm
1177
1201
1226
1251
1277
1304
1332
1360
1389
1418
1447
1477
1508

External Static Pressure (in. wg)


1.6
Watts
Rpm
Bhp
Watts
1360
1385
1.74
1549
1447
1405
1.84
1638
1542
1427
1.95
1736
1646
1448
2.07
1842
1758
1471
2.20
1956
1878
1494
2.34
2080
2008
1518
2.49
2213
2147
1543
2.65
2355
2295
1568
2.82
2507
2454

Rpm
1448
1467
1488
1508
1530
1553
1576
1599

1.8
Bhp
1.97
2.07
2.18
2.30
2.44
2.58
2.73
2.89

Watts
1748
1839
1939
2047
2164
2290
2425
2571

Rpm
1508
1527
1546
1566
1587
1609

50TFF007 (6 TONS) HIGH-STATIC MOTOR (Belt Drive)* (cont)


Airflow
(Cfm)
1800
1900
2000
2100
2200
2300
2400
2500
2600
2700
2800
2900
3000
Bhp
Watts

Rpm
1250
1273
1296
1320
1345
1371
1397
1424
1451
1479
1507

1.2
Bhp
1.33
1.43
1.53
1.64
1.77
1.90
2.04
2.19
2.36
2.53
2.72

Watts
1181
1266
1359
1459
1568
1686
1812
1948
2093
2248
2412

Rpm
1319
1341
1363
1386
1409
1434
1459
1484
1511
1537

1.4
Bhp
1.53
1.63
1.74
1.85
1.98
2.11
2.26
2.42
2.58
2.76

LEGEND
Brake Horsepower Input to Fan
Input Watts to Motor

*Motor drive range: 1300 to 1685 rpm. All other rpms require field-supplied drive.

2.0

NOTES:
1. Boldface indicates field-supplied drive is required.
2. Maximum continuous bhp is 2.90.
3. See page 32 for general fan performance notes.

53

50TFF

1800
1900
2000
2100
2200
2300
2400
2500
2600
2700
2800
2900
3000

Rpm
823
857
892
927
962
997
1033
1069
1106
1142
1179
1216
1253

0.2
Bhp
0.52
0.59
0.67
0.77
0.87
0.97
1.09
1.22
1.36
1.51
1.67
1.84
2.02

Performance data 50TFF (cont)


FAN PERFORMANCE HORIZONTAL DISCHARGE UNITS (cont)
50TFF008 (71/2 TONS) STANDARD MOTOR (Belt Drive)*
External Static Pressure (in. wg)
0.6
Watts
Rpm
Bhp
Watts
Rpm
621
629
0.84
786
694
648
634
0.88
817
698
705
644
0.94
880
708
767
653
1.02
948
717
799
658
1.05
983
722
832
663
1.09
1020
727
902
674
1.18
1096
736
976
684
1.26
1176
746
1054
694
1.35
1261
756
1137
705
1.45
1351
766
1224
716
1.55
1445
776
1317
727
1.66
1545
786
1414
738
1.77
1649
797
1517
749
1.89
1759
807
1625
760
2.01
1874
818
1738
771
2.14
1995

1857
783
2.27
2121

1918
788
2.34
2187

0.8
Bhp
1.03
1.06
1.14
1.22
1.26
1.30
1.39
1.48
1.58
1.68
1.79
1.90
2.02
2.15
2.28

Watts
959
992
1061
1134
1173
1212
1294
1381
1472
1568
1669
1774
1885
2002
2124

Rpm
752
757
765
774
779
784
793
802
812
821
831
841
851

1.0
Bhp
1.22
1.26
1.34
1.42
1.47
1.51
1.61
1.71
1.81
1.92
2.03
2.15
2.28

Watts
1138
1174
1248
1327
1368
1410
1498
1590
1687
1789
1896
2008
2125

50TFF008 (71/2 TONS) STANDARD MOTOR (Belt Drive)* (cont)


External Static Pressure (in. wg)
Airflow
1.2
1.4
1.6
(Cfm)
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
2250
806
1.42
1326
855
1.63
1521
902
1.85
1723
946
810
1.46
1363
859
1.67
1561
906
1.89
1765
950
2300
818
1.55
1443
868
1.76
1644
914
1.99
1853
958
2400
827
1.64
1527
876
1.86
1733
922
2.09
1946
966
2500
832
1.68
1570
880
1.91
1779
926
2.14
1994
970
2550
836
1.73
1615
885
1.96
1826
931
2.19
2043

2600
845
1.83
1708
893
2.06
1923
939
2.30
2146

2700
854
1.94
1805
902
2.17
2026

2800
863
2.05
1907
911
2.29
2134

2900
872
2.16
2015

3000
882
2.28
2127

3100

3200

3300

3400

3500

3600

3700

3750

1.8
Bhp
2.07
2.12
2.22
2.32
2.38

Watts
1932
1976
2068
2165
2215

Rpm
988
991

2.0
Bhp
2.30
2.35

Watts
2148
2194

Airflow
(Cfm)

50TFF

2250
2300
2400
2500
2550
2600
2700
2800
2900
3000
3100
3200
3300
3400
3500
3600
3700
3750

Rpm
465
471
483
495
501
507
519
532
544
557
570
582
595
608
622
635
648
655

0.2
Bhp
0.49
0.52
0.57
0.63
0.66
0.69
0.76
0.83
0.91
0.99
1.07
1.17
1.26
1.36
1.47
1.58
1.70
1.77

Watts
459
483
534
588
617
647
709
775
846
922
1002
1087
1177
1271
1372
1477
1588
1646

Rpm
555
560
570
581
586
592
603
614
625
637
648
660
671
683
695
707
720
726

0.4
Bhp
0.67
0.69
0.76
0.82
0.86
0.89
0.97
1.05
1.13
1.22
1.31
1.41
1.52
1.63
1.74
1.86
1.99
2.06

LEGEND
Bhp
Brake Horsepower Input to Fan
Watts Input Watts to Motor
*Motor drive range: 590 to 840 rpm. All other rpms require fieldsupplied drive.

54

NOTES:
1. Boldface indicates field-supplied drive is required.
2. Maximum continuous bhp is 2.40.
3. See page 32 for general fan performance notes.

FAN PERFORMANCE HORIZONTAL DISCHARGE UNITS (cont)


50TFF008 (71/2 TONS) ALTERNATE MOTOR (Belt Drive)*
0.8
Bhp
1.03
1.06
1.14
1.22
1.26
1.30
1.39
1.48
1.58
1.68
1.79
1.90
2.02
2.15
2.28

Watts
959
992
1061
1134
1173
1212
1294
1381
1472
1568
1669
1774
1885
2002
2124

Rpm
752
757
765
774
779
784
793
802
812
821
831
841
851

1.0
Bhp
1.22
1.26
1.34
1.42
1.47
1.51
1.61
1.71
1.81
1.92
2.03
2.15
2.28

Watts
1138
1174
1248
1327
1368
1410
1498
1590
1687
1789
1896
2008
2125

50TFF008 (71/2 TONS) ALTERNATE MOTOR (Belt Drive)* (cont)


External Static Pressure (in. wg)
Airflow
1.2
1.4
1.6
(Cfm)
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
2250
806
1.42
1326
855
1.63
1521
902
1.85
1723
946
810
1.46
1363
859
1.67
1561
906
1.89
1765
950
2300
818
1.55
1443
868
1.76
1644
914
1.99
1853
958
2400
827
1.64
1527
876
1.86
1733
922
2.09
1946
966
2500
832
1.68
1570
880
1.91
1779
926
2.14
1994
970
2550
836
1.73
1615
885
1.96
1826
931
2.19
2043

2600
845
1.83
1708
893
2.06
1923
939
2.30
2146

2700
854
1.94
1805
902
2.17
2026

2800
863
2.05
1907
911
2.29
2134

2900
872
2.16
2015

3000
882
2.28
2127

3100

3200

3300

3400

3500

3600

3700

3750

1.8
Bhp
2.07
2.12
2.22
2.32
2.38

Watts
1932
1976
2068
2165
2215

Rpm
988
991

2.0
Bhp
2.30
2.35

Watts
2148
2194

2250
2300
2400
2500
2550
2600
2700
2800
2900
3000
3100
3200
3300
3400
3500
3600
3700
3750

Rpm
465
471
483
495
501
507
519
532
544
557
570
582
595
608
622
635
648
655

0.2
Bhp
0.49
0.52
0.57
0.63
0.66
0.69
0.76
0.83
0.91
0.99
1.07
1.17
1.26
1.36
1.47
1.58
1.70
1.77

Watts
459
483
534
588
617
647
709
775
846
922
1002
1087
1177
1271
1372
1477
1588
1646

Rpm
555
560
570
581
586
592
603
614
625
637
648
660
671
683
695
707
720
726

0.4
Bhp
0.67
0.69
0.76
0.82
0.86
0.89
0.97
1.05
1.13
1.22
1.31
1.41
1.52
1.63
1.74
1.86
1.99
2.06

LEGEND
Bhp
Brake Horsepower Input to Fan
Watts Input Watts to Motor
*Motor drive range: 685 to 935 rpm. All other rpms require fieldsupplied drive.

NOTES:
1. Boldface indicates field-supplied drive is required.
2. Maximum continuous bhp is 2.40.
3. See page 32 for general fan performance notes.

55

50TFF

External Static Pressure (in. wg)


0.6
Watts
Rpm
Bhp
Watts
Rpm
621
629
0.84
786
694
648
634
0.88
817
698
705
644
0.94
880
708
767
653
1.02
948
717
799
658
1.05
983
722
832
663
1.09
1020
727
902
674
1.18
1096
736
976
684
1.26
1176
746
1054
694
1.35
1261
756
1137
705
1.45
1351
766
1224
716
1.55
1445
776
1317
727
1.66
1545
786
1414
738
1.77
1649
797
1517
749
1.89
1759
807
1625
760
2.01
1874
818
1738
771
2.14
1995

1857
783
2.27
2121

1918
788
2.34
2187

Airflow
(Cfm)

Performance data 50TFF (cont)


FAN PERFORMANCE HORIZONTAL DISCHARGE UNITS (cont)
50TFF008 (71/2 TONS) HIGH-STATIC MOTOR (Belt Drive)*
External Static Pressure (in. wg)
0.6
Watts
Rpm
Bhp
Watts
Rpm
621
629
0.84
786
694
648
634
0.88
817
698
705
644
0.94
880
708
767
653
1.02
948
717
799
658
1.05
983
722
832
663
1.09
1020
727
902
674
1.18
1096
736
976
684
1.26
1176
746
1054
694
1.35
1261
756
1137
705
1.45
1351
766
1224
716
1.55
1445
776
1317
727
1.66
1545
786
1414
738
1.77
1649
797
1517
749
1.89
1759
807
1625
760
2.01
1874
818
1738
771
2.14
1995
829
1857
783
2.27
2121
839
1918
788
2.34
2187
845

0.8
Bhp
1.03
1.06
1.14
1.22
1.26
1.30
1.39
1.48
1.58
1.68
1.79
1.90
2.02
2.15
2.28
2.41
2.56
2.63

Watts
959
992
1061
1134
1173
1212
1294
1381
1472
1568
1669
1774
1885
2002
2124
2252
2385
2454

Rpm
752
757
765
774
779
784
793
802
812
821
831
841
851
861
871
881
892
897

1.0
Bhp
1.22
1.26
1.34
1.42
1.47
1.51
1.61
1.71
1.81
1.92
2.03
2.15
2.28
2.41
2.55
2.69
2.84
2.92

Watts
1138
1174
1248
1327
1368
1410
1498
1590
1687
1789
1896
2008
2125
2248
2376
2510
2650
2722

50TFF008 (71/2 TONS) HIGH-STATIC MOTOR (Belt Drive)* (cont)


External Static Pressure (in. wg)
Airflow
1.2
1.4
1.6
(Cfm)
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
2250
806
1.42
1326
855
1.63
1521
902
1.85
1723
946
810
1.46
1363
859
1.67
1561
906
1.89
1765
950
2300
818
1.55
1443
868
1.76
1644
914
1.99
1853
958
2400
827
1.64
1527
876
1.86
1733
922
2.09
1946
966
2500
832
1.68
1570
880
1.91
1779
926
2.14
1994
970
2550
836
1.73
1615
885
1.96
1826
931
2.19
2043
974
2600
845
1.83
1708
893
2.06
1923
939
2.30
2146
982
2700
854
1.94
1805
902
2.17
2026
948
2.42
2253
991
2800
863
2.05
1907
911
2.29
2134
956
2.54
2366
999
2900
872
2.16
2015
920
2.41
2246
965
2.66
2483
1008
3000
882
2.28
2127
929
2.54
2365
974
2.80
2607
1016
3100
891
2.41
2245
938
2.67
2488
983
2.93
2735
1025
3200
901
2.54
2369
948
2.81
2617
992
3.08
2869
1034
3300
911
2.68
2497
957
2.95
2751
1001
3.23
3010
1043
3400
921
2.82
2632
967
3.10
2891
1011
3.38
3155
1052
3500
930
2.97
2772
977
3.26
3038
1020
3.55
3307

3600
941
3.13
2918
986
3.42
3190

3700
946
3.21
2994
991
3.50
3268

3750

1.8
Bhp
2.07
2.12
2.22
2.32
2.38
2.43
2.55
2.67
2.79
2.92
3.06
3.20
3.35
3.51
3.67

Watts
1932
1976
2068
2165
2215
2267
2374
2486
2603
2726
2854
2988
3127
3273
3424

Rpm
988
991
999
1007
1011
1015
1023
1031
1040
1048
1057
1065
1074

2.0
Bhp
2.30
2.35
2.46
2.56
2.62
2.68
2.80
2.92
3.05
3.19
3.33
3.48
3.64

Watts
2148
2194
2290
2391
2444
2497
2609
2725
2847
2974
3107
3246
3390

Airflow
(Cfm)

50TFF

2250
2300
2400
2500
2550
2600
2700
2800
2900
3000
3100
3200
3300
3400
3500
3600
3700
3750

Rpm
465
471
483
495
501
507
519
532
544
557
570
582
595
608
622
635
648
655

0.2
Bhp
0.49
0.52
0.57
0.63
0.66
0.69
0.76
0.83
0.91
0.99
1.07
1.17
1.26
1.36
1.47
1.58
1.70
1.77

Watts
459
483
534
588
617
647
709
775
846
922
1002
1087
1177
1271
1372
1477
1588
1646

Rpm
555
560
570
581
586
592
603
614
625
637
648
660
671
683
695
707
720
726

0.4
Bhp
0.67
0.69
0.76
0.82
0.86
0.89
0.97
1.05
1.13
1.22
1.31
1.41
1.52
1.63
1.74
1.86
1.99
2.06

LEGEND
Bhp
Brake Horsepower Input to Fan
Watts Input Watts to Motor
*Motor drive range: 860 to 1080 rpm. All other rpms require fieldsupplied drive.

56

NOTES:
1. Boldface indicates field-supplied drive is required.
2. Maximum continuous bhp is 3.70.
3. See page 32 for general fan performance notes.

FAN PERFORMANCE HORIZONTAL DISCHARGE UNITS (cont)


50TFF009 (81/2 TONS) STANDARD MOTOR (Belt Drive)*
0.8
Bhp
1.26
1.30
1.39
1.48
1.58
1.68
1.79
1.90
2.02
2.15
2.28

Watts
1173
1212
1294
1381
1472
1568
1669
1774
1885
2002
2124

Rpm
779
784
793
802
812
821
831
841
851

1.0
Bhp
1.47
1.51
1.61
1.71
1.81
1.92
2.03
2.15
2.28

Watts
1368
1410
1498
1590
1687
1789
1896
2008
2125

50TFF009 (81/2 TONS) STANDARD MOTOR (Belt Drive)* (cont)


External Static Pressure (in. wg)
Airflow
1.2
1.4
1.6
(Cfm)
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
2550
832
1.68
1570
880
1.91
1779
926
2.14
1994
970
836
1.73
1615
885
1.96
1826
931
2.19
2043

2600
845
1.83
1708
893
2.06
1923
939
2.30
2146

2700
854
1.94
1805
902
2.17
2026

2800
863
2.05
1907
911
2.29
2134

2900
872
2.16
2015

3000
882
2.28
2127

3100

3200

3300

3400

3500

3600

3700

3750

3800

3900

4000

4100

4200

4250

1.8
Bhp
2.38

Watts
2215

Rpm

2.0
Bhp

Watts

2550
2600
2700
2800
2900
3000
3100
3200
3300
3400
3500
3600
3700
3750
3800
3900
4000
4100
4200
4250

Rpm
501
507
519
532
544
557
570
582
595
608
622
635
648
655
662
675
689
702
716

0.2
Bhp
0.66
0.69
0.76
0.83
0.91
0.99
1.07
1.17
1.26
1.36
1.47
1.58
1.70
1.77
1.83
1.96
2.10
2.24
2.40

Watts
617
647
709
775
846
922
1002
1087
1177
1271
1372
1477
1588
1646
1705
1828
1957
2092
2234

Rpm
586
592
603
614
625
637
648
660
671
683
695
707
720
726
732
744

0.4
Bhp
0.86
0.89
0.97
1.05
1.13
1.22
1.31
1.41
1.52
1.63
1.74
1.86
1.99
2.06
2.13
2.26

LEGEND
Bhp
Brake Horsepower Input to Fan
Watts Input Watts to Motor
*Motor drive range: 685 to 935 rpm. All other rpms require fieldsupplied drive.

NOTES:
1. Boldface indicates field-supplied drive is required.
2. Maximum continuous bhp is 2.40.
3. See page 32 for general fan performance notes.

57

50TFF

External Static Pressure (in. wg)


0.6
Watts
Rpm
Bhp
Watts
Rpm
799
658
1.05
983
722
832
663
1.09
1020
727
902
674
1.18
1096
736
976
684
1.26
1176
746
1054
694
1.35
1261
756
1137
705
1.45
1351
766
1224
716
1.55
1445
776
1317
727
1.66
1545
786
1414
738
1.77
1649
797
1517
749
1.89
1759
807
1625
760
2.01
1874
818
1738
771
2.14
1995

1857
783
2.27
2121

1918
788
2.34
2187

1982

2112

Airflow
(Cfm)

Performance data 50TFF (cont)


FAN PERFORMANCE HORIZONTAL DISCHARGE UNITS (cont)
50TFF009 (81/2 TONS) HIGH-STATIC MOTOR (Belt Drive)*
External Static Pressure (in. wg)
0.6
Watts
Rpm
Bhp
Watts
Rpm
799
658
1.05
983
722
832
663
1.09
1020
727
902
674
1.18
1096
736
976
684
1.26
1176
746
1054
694
1.35
1261
756
1137
705
1.45
1351
766
1224
716
1.55
1445
776
1317
727
1.66
1545
786
1414
738
1.77
1649
797
1517
749
1.89
1759
807
1625
760
2.01
1874
818
1738
771
2.14
1995
829
1857
783
2.27
2121
839
1918
788
2.34
2187
845
1982
794
2.42
2253
850
2112
806
2.56
2392
861
2249
817
2.72
2536
873
2392
829
2.88
2686
884
2541
841
3.05
2843
895
2619
847
3.14
2924
901

0.8
Bhp
1.26
1.30
1.39
1.48
1.58
1.68
1.79
1.90
2.02
2.15
2.28
2.41
2.56
2.63
2.71
2.86
3.02
3.19
3.37
3.46

Watts
1173
1212
1294
1381
1472
1568
1669
1774
1885
2002
2124
2252
2385
2454
2524
2669
2820
2978
3143
3227

Rpm
779
784
793
802
812
821
831
841
851
861
871
881
892
897
902
913
924
935
945

1.0
Bhp
1.47
1.51
1.61
1.71
1.81
1.92
2.03
2.15
2.28
2.41
2.55
2.69
2.84
2.92
3.00
3.16
3.33
3.51
3.69

Watts
1368
1410
1498
1590
1687
1789
1896
2008
2125
2248
2376
2510
2650
2722
2796
2948
3106
3271
3442

50TFF009 (81/2 TONS) HIGH-STATIC MOTOR (Belt Drive)* (cont)


External Static Pressure (in. wg)
Airflow
1.2
1.4
1.6
(Cfm)
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
2550
832
1.68
1570
880
1.91
1779
926
2.14
1994
970
836
1.73
1615
885
1.96
1826
931
2.19
2043
974
2600
845
1.83
1708
893
2.06
1923
939
2.30
2146
982
2700
854
1.94
1805
902
2.17
2026
948
2.42
2253
991
2800
863
2.05
1907
911
2.29
2134
956
2.54
2366
999
2900
872
2.16
2015
920
2.41
2246
965
2.66
2483
1008
3000
882
2.28
2127
929
2.54
2365
974
2.80
2607
1016
3100
891
2.41
2245
938
2.67
2488
983
2.93
2735
1025
3200
901
2.54
2369
948
2.81
2617
992
3.08
2869
1034
3300
911
2.68
2497
957
2.95
2751
1001
3.23
3010
1043
3400
921
2.82
2632
967
3.10
2891
1011
3.38
3155
1052
3500
930
2.97
2772
977
3.26
3038
1020
3.55
3307

3600
941
3.13
2918
986
3.42
3190

3700
946
3.21
2994
991
3.50
3268

3750
951
3.29
3071
996
3.59
3348

3800
961
3.46
3229

3900
971
3.64
3393

4000

4100

4200

4250

1.8
Bhp
2.38
2.43
2.55
2.67
2.79
2.92
3.06
3.20
3.35
3.51
3.67

Watts
2215
2267
2374
2486
2603
2726
2854
2988
3127
3273
3424

Rpm
1011
1015
1023
1031
1040
1048
1057
1065
1074

2.0
Bhp
2.62
2.68
2.80
2.92
3.05
3.19
3.33
3.48
3.64

Watts
2444
2497
2609
2725
2847
2974
3107
3246
3390

Airflow
(Cfm)

50TFF

2550
2600
2700
2800
2900
3000
3100
3200
3300
3400
3500
3600
3700
3750
3800
3900
4000
4100
4200
4250

Rpm
501
507
519
532
544
557
570
582
595
608
622
635
648
655
662
675
689
702
716
723

0.2
Bhp
0.66
0.69
0.76
0.83
0.91
0.99
1.07
1.17
1.26
1.36
1.47
1.58
1.70
1.77
1.83
1.96
2.10
2.24
2.40
2.47

Watts
617
647
709
775
846
922
1002
1087
1177
1271
1372
1477
1588
1646
1705
1828
1957
2092
2234
2307

Rpm
586
592
603
614
625
637
648
660
671
683
695
707
720
726
732
744
757
769
782
788

0.4
Bhp
0.86
0.89
0.97
1.05
1.13
1.22
1.31
1.41
1.52
1.63
1.74
1.86
1.99
2.06
2.13
2.26
2.41
2.57
2.73
2.81

LEGEND
Bhp
Brake Horsepower Input to Fan
Watts Input Watts to Motor
*Motor drive range: 860 to 1080 rpm. All other rpms require fieldsupplied drive.

58

NOTES:
1. Boldface indicates field-supplied drive is required.
2. Maximum continuous bhp is 3.70.
3. See page 32 for general fan performance notes.

FAN PERFORMANCE HORIZONTAL DISCHARGE UNITS (cont)


50TFF012 (10 TONS) STANDARD MOTOR (Belt Drive)*
0.8
Bhp
1.01
1.07
1.13
1.20
1.27
1.35
1.42
1.50
1.59
1.68
1.77
1.87
1.97
2.07
2.18
2.30

Watts
888
941
996
1055
1116
1181
1249
1320
1395
1473
1554
1639
1728
1821
1917
2017

Rpm
747
754
761
768
776
784
792
799
808
816
824
832
841
850
858

1.0
Bhp
1.18
1.24
1.31
1.38
1.45
1.52
1.60
1.69
1.78
1.87
1.96
2.06
2.17
2.28
2.39

Watts
1035
1089
1146
1207
1271
1338
1408
1482
1559
1640
1724
1811
1903
1999
2098

50TFF012 (10 TONS) STANDARD MOTOR (Belt Drive)* (cont)


External Static Pressure (in. wg)
Airflow
1.2
1.4
1.6
(Cfm)
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
3000
798
1.36
1191
846
1.55
1357
892
1.75
1534
935
3100
805
1.42
1247
853
1.61
1415
898
1.81
1592
941
3200
812
1.49
1306
859
1.68
1476
904
1.88
1654
947
3300
819
1.56
1369
866
1.75
1539
911
1.96
1719
953
3400
826
1.63
1434
873
1.83
1606
917
2.04
1788
959
3500
833
1.71
1503
880
1.91
1677
924
2.12
1860
966
3600
841
1.80
1576
887
2.00
1751
931
2.21
1936

3700
848
1.88
1651
894
2.08
1829
938
2.30
2015

3800
856
1.97
1731
901
2.18
1911
945
2.39
2098

3900
864
2.07
1814
909
2.27
1995

4000
872
2.17
1900
916
2.37
2084

4100
880
2.27
1991

4200
888
2.38
2085

4300

4400

4500

4600

4700

4800

4900

5000

1.8
Bhp
1.96
2.03
2.10
2.17
2.25
2.34

Watts
1719
1779
1842
1908
1978
2051

Rpm
976
982
987
994

2.0
Bhp
2.18
2.25
2.32
2.40

Watts
1915
1974
2038
2106

3000
3100
3200
3300
3400
3500
3600
3700
3800
3900
4000
4100
4200
4300
4400
4500
4600
4700
4800
4900
5000

Rpm
484
494
505
516
526
537
548
559
571
582
593
604
616
627
639
650
662
674
685
697
709

0.2
Bhp
0.58
0.63
0.68
0.74
0.80
0.86
0.93
1.00
1.07
1.15
1.23
1.32
1.41
1.50
1.60
1.70
1.81
1.92
2.03
2.15
2.28

Watts
506
550
597
647
699
755
813
875
940
1008
1080
1155
1233
1316
1402
1492
1585
1683
1785
1891
2001

Rpm
562
571
581
590
600
609
619
629
639
649
659
669
680
690
701
711
722
733
744
754

0.4
Bhp
0.71
0.77
0.82
0.88
0.95
1.01
1.09
1.16
1.24
1.32
1.41
1.50
1.59
1.69
1.79
1.90
2.01
2.12
2.24
2.37

LEGEND
Bhp
Brake Horsepower Input to Fan
Watts Input Watts to Motor
*Motor drive range: 685 to 935 rpm. All other rpms require fieldsupplied drive.

NOTES:
1. Boldface indicates field-supplied drive is required.
2. Maximum continuous bhp is 2.40.
3. See page 32 for general fan performance notes.

59

50TFF

External Static Pressure (in. wg)


0.6
Watts
Rpm
Bhp
Watts
Rpm
625
630
0.86
752
691
672
638
0.91
802
699
723
647
0.97
855
706
776
655
1.04
911
714
832
664
1.11
970
722
891
673
1.18
1032
731
953
682
1.25
1097
739
1018
691
1.33
1166
747
1087
700
1.41
1237
756
1158
709
1.50
1313
765
1234
719
1.59
1391
773
1312
728
1.68
1473
782
1395
738
1.78
1559
791
1481
747
1.88
1648
800
1570
757
1.98
1741
809
1664
767
2.10
1839
819
1762
777
2.21
1940

1863
787
2.33
2045

1969

2078

Airflow
(Cfm)

Performance data 50TFF (cont)


FAN PERFORMANCE HORIZONTAL DISCHARGE UNITS (cont)
50TFF012 (10 TONS) ALTERNATE MOTOR (Belt Drive)*
External Static Pressure (in. wg)
0.6
Watts
Rpm
Bhp
Watts
Rpm
625
630
0.86
752
691
672
638
0.91
802
699
723
647
0.97
855
706
776
655
1.04
911
714
832
664
1.11
970
722
891
673
1.18
1032
731
953
682
1.25
1097
739
1018
691
1.33
1166
747
1087
700
1.41
1237
756
1158
709
1.50
1313
765
1234
719
1.59
1391
773
1312
728
1.68
1473
782
1395
738
1.78
1559
791
1481
747
1.88
1648
800
1570
757
1.98
1741
809
1664
767
2.10
1839
819
1762
777
2.21
1940
828
1863
787
2.33
2045
838
1969
797
2.45
2154
847
2078
807
2.58
2268
857
2193
818
2.72
2385

0.8
Bhp
1.01
1.07
1.13
1.20
1.27
1.35
1.42
1.50
1.59
1.68
1.77
1.87
1.97
2.07
2.18
2.30
2.42
2.54
2.67
2.80

Watts
888
941
996
1055
1116
1181
1249
1320
1395
1473
1554
1639
1728
1821
1917
2017
2122
2230
2343
2459

Rpm
747
754
761
768
776
784
792
799
808
816
824
832
841
850
858
867
876
885
894

1.0
Bhp
1.18
1.24
1.31
1.38
1.45
1.52
1.60
1.69
1.78
1.87
1.96
2.06
2.17
2.28
2.39
2.51
2.63
2.76
2.89

Watts
1035
1089
1146
1207
1271
1338
1408
1482
1559
1640
1724
1811
1903
1999
2098
2201
2308
2420
2536

50TFF012 (10 TONS) ALTERNATE MOTOR (Belt Drive)* (cont)


External Static Pressure (in. wg)
Airflow
1.2
1.4
1.6
(Cfm)
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
3000
798
1.36
1191
846
1.55
1357
892
1.75
1534
935
3100
805
1.42
1247
853
1.61
1415
898
1.81
1592
941
3200
812
1.49
1306
859
1.68
1476
904
1.88
1654
947
3300
819
1.56
1369
866
1.75
1539
911
1.96
1719
953
3400
826
1.63
1434
873
1.83
1606
917
2.04
1788
959
3500
833
1.71
1503
880
1.91
1677
924
2.12
1860
966
3600
841
1.80
1576
887
2.00
1751
931
2.21
1936
972
3700
848
1.88
1651
894
2.08
1829
938
2.30
2015
979
3800
856
1.97
1731
901
2.18
1911
945
2.39
2098
986
3900
864
2.07
1814
909
2.27
1995
952
2.49
2185
993
4000
872
2.17
1900
916
2.37
2084
959
2.59
2276
1000
4100
880
2.27
1991
924
2.48
2177
966
2.70
2370

4200
888
2.38
2085
932
2.59
2273
974
2.81
2469

4300
896
2.49
2183
940
2.70
2374

4400
904
2.60
2285
948
2.82
2478

4500
913
2.72
2391

4600
921
2.85
2501

4700

4800

4900

5000

1.8
Bhp
1.96
2.03
2.10
2.17
2.25
2.34
2.42
2.52
2.61
2.71
2.82

Watts
1719
1779
1842
1908
1978
2051
2128
2209
2294
2382
2475

Rpm
976
982
987
994
1000
1006
1012
1019
1025

2.0
Bhp
2.18
2.25
2.32
2.40
2.48
2.56
2.65
2.75
2.85

Watts
1915
1974
2038
2106
2176
2251
2329
2411
2498

Airflow
(Cfm)

50TFF

3000
3100
3200
3300
3400
3500
3600
3700
3800
3900
4000
4100
4200
4300
4400
4500
4600
4700
4800
4900
5000

Rpm
484
494
505
516
526
537
548
559
571
582
593
604
616
627
639
650
662
674
685
697
709

0.2
Bhp
0.58
0.63
0.68
0.74
0.80
0.86
0.93
1.00
1.07
1.15
1.23
1.32
1.41
1.50
1.60
1.70
1.81
1.92
2.03
2.15
2.28

Watts
506
550
597
647
699
755
813
875
940
1008
1080
1155
1233
1316
1402
1492
1585
1683
1785
1891
2001

Rpm
562
571
581
590
600
609
619
629
639
649
659
669
680
690
701
711
722
733
744
754
765

0.4
Bhp
0.71
0.77
0.82
0.88
0.95
1.01
1.09
1.16
1.24
1.32
1.41
1.50
1.59
1.69
1.79
1.90
2.01
2.12
2.24
2.37
2.50

LEGEND
Bhp
Brake Horsepower Input to Fan
Watts Input Watts to Motor
*Motor drive range: 835 to 1085 rpm. All other rpms require fieldsupplied drive.

60

NOTES:
1. Boldface indicates field-supplied drive is required.
2. Maximum continuous bhp is 2.90.
3. See page 32 for general fan performance notes.

FAN PERFORMANCE HORIZONTAL DISCHARGE UNITS (cont)


50TFF012 (10 TONS) HIGH-STATIC MOTOR (Belt Drive)*
0.8
Bhp
1.01
1.07
1.13
1.20
1.27
1.35
1.42
1.50
1.59
1.68
1.77
1.87
1.97
2.07
2.18
2.30
2.42
2.54
2.67
2.80
2.94

Watts
888
941
996
1055
1116
1181
1249
1320
1395
1473
1554
1639
1728
1821
1917
2017
2122
2230
2343
2459
2580

Rpm
747
754
761
768
776
784
792
799
808
816
824
832
841
850
858
867
876
885
894
903
912

1.0
Bhp
1.18
1.24
1.31
1.38
1.45
1.52
1.60
1.69
1.78
1.87
1.96
2.06
2.17
2.28
2.39
2.51
2.63
2.76
2.89
3.03
3.17

Watts
1035
1089
1146
1207
1271
1338
1408
1482
1559
1640
1724
1811
1903
1999
2098
2201
2308
2420
2536
2656
2780

50TFF012 (10 TONS) HIGH-STATIC MOTOR (Belt Drive)* (cont)


External Static Pressure (in. wg)
Airflow
1.2
1.4
1.6
(Cfm)
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
3000
798
1.36
1191
846
1.55
1357
892
1.75
1534
935
3100
805
1.42
1247
853
1.61
1415
898
1.81
1592
941
3200
812
1.49
1306
859
1.68
1476
904
1.88
1654
947
3300
819
1.56
1369
866
1.75
1539
911
1.96
1719
953
3400
826
1.63
1434
873
1.83
1606
917
2.04
1788
959
3500
833
1.71
1503
880
1.91
1677
924
2.12
1860
966
3600
841
1.80
1576
887
2.00
1751
931
2.21
1936
972
3700
848
1.88
1651
894
2.08
1829
938
2.30
2015
979
3800
856
1.97
1731
901
2.18
1911
945
2.39
2098
986
3900
864
2.07
1814
909
2.27
1995
952
2.49
2185
993
4000
872
2.17
1900
916
2.37
2084
959
2.59
2276
1000
4100
880
2.27
1991
924
2.48
2177
966
2.70
2370
1007
4200
888
2.38
2085
932
2.59
2273
974
2.81
2469
1014
4300
896
2.49
2183
940
2.70
2374
981
2.93
2571
1021
4400
904
2.60
2285
948
2.82
2478
989
3.05
2678
1029
4500
913
2.72
2391
956
2.95
2586
997
3.18
2788
1036
4600
921
2.85
2501
964
3.08
2699
1005
3.31
2904
1044
4700
930
2.98
2615
972
3.21
2816
1013
3.44
3023
1052
4800
938
3.11
2733
981
3.35
2937
1021
3.58
3146
1060
4900
947
3.25
2856
989
3.49
3063
1029
3.73
3275
1067
5000
956
3.40
2984
998
3.64
3193
1037
3.88
3407
1075

1.8
Bhp
1.96
2.03
2.10
2.17
2.25
2.34
2.42
2.52
2.61
2.71
2.82
2.93
3.04
3.16
3.29
3.41
3.55
3.69
3.83
3.98
4.13

Watts
1719
1779
1842
1908
1978
2051
2128
2209
2294
2382
2475
2571
2672
2776
2884
2997
3115
3236
3362
3492
3627

Rpm
976
982
987
994
1000
1006
1012
1019
1025
1032
1039
1046
1053
1060
1067
1074
1082
1089
1097
1104
1112

2.0
Bhp
2.18
2.25
2.32
2.40
2.48
2.56
2.65
2.75
2.85
2.95
3.05
3.17
3.28
3.40
3.53
3.66
3.80
3.94
4.08
4.23
4.39

Watts
1915
1974
2038
2106
2176
2251
2329
2411
2498
2587
2681
2779
2881
2987
3098
3212
3332
3455
3583
3716
3853

3000
3100
3200
3300
3400
3500
3600
3700
3800
3900
4000
4100
4200
4300
4400
4500
4600
4700
4800
4900
5000

Rpm
484
494
505
516
526
537
548
559
571
582
593
604
616
627
639
650
662
674
685
697
709

0.2
Bhp
0.58
0.63
0.68
0.74
0.80
0.86
0.93
1.00
1.07
1.15
1.23
1.32
1.41
1.50
1.60
1.70
1.81
1.92
2.03
2.15
2.28

Watts
506
550
597
647
699
755
813
875
940
1008
1080
1155
1233
1316
1402
1492
1585
1683
1785
1891
2001

Rpm
562
571
581
590
600
609
619
629
639
649
659
669
680
690
701
711
722
733
744
754
765

0.4
Bhp
0.71
0.77
0.82
0.88
0.95
1.01
1.09
1.16
1.24
1.32
1.41
1.50
1.59
1.69
1.79
1.90
2.01
2.12
2.24
2.37
2.50

LEGEND
Bhp
Brake Horsepower Input to Fan
Watts Input Watts to Motor
*Motor drive range: 830 to 1130 rpm. All other rpms require fieldsupplied drive.

NOTES:
1. Boldface indicates field-supplied drive is required.
2. Maximum continuous bhp is 5.25.
3. See page 32 for general fan performance notes.

61

50TFF

External Static Pressure (in. wg)


0.6
Watts
Rpm
Bhp
Watts
Rpm
625
630
0.86
752
691
672
638
0.91
802
699
723
647
0.97
855
706
776
655
1.04
911
714
832
664
1.11
970
722
891
673
1.18
1032
731
953
682
1.25
1097
739
1018
691
1.33
1166
747
1087
700
1.41
1237
756
1158
709
1.50
1313
765
1234
719
1.59
1391
773
1312
728
1.68
1473
782
1395
738
1.78
1559
791
1481
747
1.88
1648
800
1570
757
1.98
1741
809
1664
767
2.10
1839
819
1762
777
2.21
1940
828
1863
787
2.33
2045
838
1969
797
2.45
2154
847
2078
807
2.58
2268
857
2193
818
2.72
2385
866

Airflow
(Cfm)

Performance data 50TFF (cont)


FAN PERFORMANCE HORIZONTAL DISCHARGE UNITS (cont)
50TFF014 (121/2 TONS) STANDARD MOTOR (Belt Drive)*
External Static Pressure (in. wg)
0.6
Watts
Rpm
Bhp
Watts
Rpm
1095
728
1.36
1267
781
1167
739
1.44
1343
791
1243
750
1.53
1423
801
1322
761
1.61
1506
812
1405
773
1.71
1593
822
1492
784
1.80
1683
833
1582
796
1.91
1777
844
1677
808
2.01
1876
855
1775
820
2.12
1978
866
1877
832
2.24
2085
877
1984
844
2.35
2195
889
2095
856
2.48
2310
900
2210
869
2.61
2430
912
2330
881
2.74
2554
923
2455
894
2.88
2682
935
2584
906
3.02
2815
947
2718
919
3.17
2953
959
2856
932
3.32
3096
971
3000
945
3.48
3242

3148
958
3.64
3396

3302

0.8
Bhp
1.55
1.64
1.72
1.82
1.92
2.02
2.12
2.23
2.35
2.46
2.59
2.71
2.85
2.98
3.13
3.27
3.42
3.58

Watts
1445
1525
1608
1695
1786
1880
1979
2081
2187
2297
2412
2531
2654
2782
2914
3050
3193
3339

Rpm
832
841
850
860
870
880
890
900
910
921
932
942
953
965
976
987
999

1.0
Bhp
1.75
1.84
1.93
2.03
2.13
2.23
2.34
2.46
2.57
2.70
2.82
2.95
3.09
3.23
3.38
3.53
3.69

Watts
1629
1712
1799
1890
1984
2082
2184
2290
2400
2514
2633
2756
2883
3014
3150
3292
3437

50TFF014 (121/2 TONS) STANDARD MOTOR (Belt Drive)* (cont)


External Static Pressure (in. wg)
Airflow
1.2
1.4
1.6
(Cfm)
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
3700
881
1.95
1816
928
2.16
2010
974
2.37
2207
1019
3800
889
2.04
1904
936
2.25
2100
981
2.47
2302
1025
3900
898
2.14
1995
944
2.35
2195
988
2.57
2399
1032
4000
907
2.24
2089
952
2.46
2293
996
2.68
2501
1038
4100
916
2.35
2187
960
2.57
2395
1004
2.80
2607
1046
4200
925
2.45
2289
969
2.68
2500
1011
2.91
2716
1053
4300
934
2.57
2395
978
2.80
2610
1020
3.03
2828
1061
4400
944
2.69
2504
986
2.92
2723
1028
3.16
2946
1068
4500
954
2.81
2618
996
3.05
2840
1037
3.29
3067
1076
4600
963
2.93
2736
1005
3.18
2962
1045
3.42
3192
1085
4700
974
3.07
2858
1014
3.31
3088
1054
3.56
3322

4800
984
3.20
2985
1024
3.45
3219

4900
994
3.34
3116
1034
3.60
3353

5000
1005
3.49
3251

5100
1015
3.64
3391

5200

5300

5400

5500

5600

5700

5800

5900

6000

6100

6200

6300

1.8
Bhp
2.58
2.69
2.80
2.91
3.03
3.15
3.27
3.40
3.54
3.67

Watts
2409
2507
2608
2713
2822
2935
3052
3173
3297
3426

Rpm
1062
1068
1074
1080
1087
1094
1101
1108

2.0
Bhp
2.80
2.91
3.03
3.14
3.26
3.39
3.52
3.65

Watts
2615
2716
2821
2930
3042
3159
3279
3403

Airflow
(Cfm)

50TFF

3700
3800
3900
4000
4100
4200
4300
4400
4500
4600
4700
4800
4900
5000
5100
5200
5300
5400
5500
5600
5700
5800
5900
6000
6100
6200
6300

Rpm
614
628
641
655
668
682
696
710
723
737
751
765
779
793
807
821
835
850
864
878
892
907
921

0.2
Bhp
1.00
1.07
1.15
1.23
1.31
1.40
1.49
1.59
1.69
1.80
1.91
2.02
2.14
2.26
2.39
2.53
2.67
2.81
2.96
3.12
3.28
3.44
3.61

Watts
929
997
1069
1144
1223
1305
1392
1482
1577
1675
1778
1885
1996
2112
2232
2357
2487
2622
2762
2906
3055
3211
3370

Rpm
673
685
697
709
722
734
747
760
773
785
798
812
825
838
851
864
878
891
905
918
932

0.4
Bhp
1.17
1.25
1.33
1.42
1.51
1.60
1.70
1.80
1.90
2.01
2.13
2.25
2.37
2.50
2.63
2.77
2.91
3.06
3.22
3.38
3.54

LEGEND
Bhp
Brake Horsepower Input to Fan
Watts Input Watts to Motor
*Motor drive range: 860 to 1080 rpm. All other rpms require fieldsupplied drive.

62

NOTES:
1. Boldface indicates field-supplied drive is required.
2. Maximum continuous bhp is 3.70.
3. See page 32 for general fan performance notes.

FAN PERFORMANCE HORIZONTAL DISCHARGE UNITS (cont)


50TFF014 (121/2 TONS) ALTERNATE MOTOR (Belt Drive)*
Airflow
(Cfm)

Watts
929
997
1069
1144
1223
1305
1392
1482
1577
1675
1778
1885
1996
2112
2232
2357
2487
2622
2762
2906
3055
3211
3370
3536
3707
3883
4066

Rpm
673
685
697
709
722
734
747
760
773
785
798
812
825
838
851
864
878
891
905
918
932
945
959
973
987
1000
1014

0.4
Bhp
1.17
1.25
1.33
1.42
1.51
1.60
1.70
1.80
1.90
2.01
2.13
2.25
2.37
2.50
2.63
2.77
2.91
3.06
3.22
3.38
3.54
3.71
3.89
4.07
4.26
4.45
4.65

External Static Pressure (in. wg)


0.6
Watts
Rpm
Bhp
Watts
Rpm
1095
728
1.36
1267
781
1167
739
1.44
1343
791
1243
750
1.53
1423
801
1322
761
1.61
1506
812
1405
773
1.71
1593
822
1492
784
1.80
1683
833
1582
796
1.91
1777
844
1677
808
2.01
1876
855
1775
820
2.12
1978
866
1877
832
2.24
2085
877
1984
844
2.35
2195
889
2095
856
2.48
2310
900
2210
869
2.61
2430
912
2330
881
2.74
2554
923
2455
894
2.88
2682
935
2584
906
3.02
2815
947
2718
919
3.17
2953
959
2856
932
3.32
3096
971
3000
945
3.48
3242
984
3148
958
3.64
3396
996
3302
971
3.81
3554
1008
3461
984
3.99
3716
1021
3626
997
4.17
3885
1033
3795
1010
4.35
4059
1046
3970
1023
4.54
4238
1059
4151
1036
4.74
4422
1071
4337
1050
4.95
4613
1084

0.8
Bhp
1.55
1.64
1.72
1.82
1.92
2.02
2.12
2.23
2.35
2.46
2.59
2.71
2.85
2.98
3.13
3.27
3.42
3.58
3.74
3.91
4.09
4.26
4.45
4.64
4.84
5.04
5.25

Watts
1445
1525
1608
1695
1786
1880
1979
2081
2187
2297
2412
2531
2654
2782
2914
3050
3193
3339
3491
3648
3810
3976
4149
4326
4510
4698
4892

Rpm
832
841
850
860
870
880
890
900
910
921
932
942
953
965
976
987
999
1010
1022
1034
1045
1057
1069
1082
1094

1.0
Bhp
1.75
1.84
1.93
2.03
2.13
2.23
2.34
2.46
2.57
2.70
2.82
2.95
3.09
3.23
3.38
3.53
3.69
3.85
4.01
4.19
4.36
4.55
4.74
4.93
5.13

Watts
1629
1712
1799
1890
1984
2082
2184
2290
2400
2514
2633
2756
2883
3014
3150
3292
3437
3588
3743
3903
4069
4240
4416
4598
4785

1.8
Bhp
2.58
2.69
2.80
2.91
3.03
3.15
3.27
3.40
3.54
3.67
3.82
3.96
4.12
4.27
4.44
4.60
4.78
4.95
5.14

Watts
2409
2507
2608
2713
2822
2935
3052
3173
3297
3426
3560
3697
3839
3986
4137
4293
4454
4619
4790

Rpm
1062
1068
1074
1080
1087
1094
1101
1108
1115
1123
1131
1139
1148
1156
1165
1174
1183
1192

2.0
Bhp
2.80
2.91
3.03
3.14
3.26
3.39
3.52
3.65
3.79
3.93
4.08
4.23
4.38
4.55
4.71
4.88
5.06
5.24

Watts
2615
2716
2821
2930
3042
3159
3279
3403
3531
3664
3801
3943
4088
4238
4393
4553
4718
4886

50TFF014 (121/2 TONS) ALTERNATE MOTOR (Belt Drive)*


Airflow
(Cfm)
3700
3800
3900
4000
4100
4200
4300
4400
4500
4600
4700
4800
4900
5000
5100
5200
5300
5400
5500
5600
5700
5800
5900
6000
6100
6200
6300

Rpm
881
889
898
907
916
925
934
944
954
963
974
984
994
1005
1015
1026
1037
1048
1059
1070
1082
1093
1105
1116

1.2
Bhp
1.95
2.04
2.14
2.24
2.35
2.45
2.57
2.69
2.81
2.93
3.07
3.20
3.34
3.49
3.64
3.79
3.95
4.12
4.29
4.46
4.65
4.83
5.03
5.23

Watts
1816
1904
1995
2089
2187
2289
2395
2504
2618
2736
2858
2985
3116
3251
3391
3536
3685
3840
3999
4163
4333
4508
4688
4873

Rpm
928
936
944
952
960
969
978
986
996
1005
1014
1024
1034
1044
1054
1064
1075
1085
1096
1106
1117
1128

1.4
Bhp
2.16
2.25
2.35
2.46
2.57
2.68
2.80
2.92
3.05
3.18
3.31
3.45
3.60
3.74
3.90
4.06
4.22
4.39
4.57
4.75
4.93
5.13

External Static Pressure (in. wg)


1.6
Watts
Rpm
Bhp
Watts
Rpm
2010
974
2.37
2207
1019
2100
981
2.47
2302
1025
2195
988
2.57
2399
1032
2293
996
2.68
2501
1038
2395
1004
2.80
2607
1046
2500
1011
2.91
2716
1053
2610
1020
3.03
2828
1061
2723
1028
3.16
2946
1068
2840
1037
3.29
3067
1076
2962
1045
3.42
3192
1085
3088
1054
3.56
3322
1093
3219
1063
3.71
3456
1102
3353
1073
3.85
3594
1111
3492
1082
4.01
3737
1119
3636
1092
4.17
3885
1129
3784
1101
4.33
4037
1138
3938
1111
4.50
4194
1147
4096
1121
4.67
4356
1157
4259
1132
4.85
4523
1167
4427
1142
5.03
4695

4601
1152
5.22
4872

4779

LEGEND
Bhp
Brake Horsepower Input to Fan
Watts Input Watts to Motor
*Motor drive range: 830 to 1130 rpm. All other rpms require fieldsupplied drive.

NOTES:
1. Boldface indicates field-supplied drive is required.
2. Maximum continuous bhp is 5.25.
3. See page 32 for general fan performance notes.

63

50TFF

3700
3800
3900
4000
4100
4200
4300
4400
4500
4600
4700
4800
4900
5000
5100
5200
5300
5400
5500
5600
5700
5800
5900
6000
6100
6200
6300

Rpm
614
628
641
655
668
682
696
710
723
737
751
765
779
793
807
821
835
850
864
878
892
907
921
935
949
964
978

0.2
Bhp
1.00
1.07
1.15
1.23
1.31
1.40
1.49
1.59
1.69
1.80
1.91
2.02
2.14
2.26
2.39
2.53
2.67
2.81
2.96
3.12
3.28
3.44
3.61
3.79
3.98
4.16
4.36

Performance data 50TFF (cont)

50TFF

FAN RPM AT MOTOR PULLEY SETTINGS* 50TFF004-007


UNIT
50TFF

1/

004
004**
005
005**
006
006**
007
007**

1000
1455
1185
1455
1300
1685
1460
1685

976
1423
1150
1423
1267
1647
1421
1647

11/2

952
1392
1115
1392
1233
1608
1382
1608

928
1360
1080
1360
1200
1570
1343
1570

904
1328
1045
1328
1167
1531
1304
1531

*Approximate fan rpm shown.


Indicates alternate motor and drive package.

MOTOR PULLEY TURNS OPEN


21/2
3
31/2
880
1297
1010
1297
1133
1493
1265
1493

856
1265
975
1265
1100
1454
1226
1454

832
1233
940
1233
1067
1416
1187
1416

41/2

51/2

808
1202
905
1202
1033
1377
1148
1377

784
1170
810
1170
1000
1339
1109
1339

760
1138
835
1138
967
1300
1070
1300

1107

1107
933

1075

1075
900

**Indicates high-static motor and drive package.


Indicates standard motor and drive package.

FAN RPM AT MOTOR PULLEY SETTINGS* 50TFF008-014


UNIT
50TFF
008
008**
008
009
009
012
012***
012
014
014***

0
840
935
1080
935
1080
935
1085
1130
1080
1130

1/

815
910
1025
910
1025
910
1060
1112
1060
1112

1
790
885
1007
885
1007
885
1035
1087
1035
1087

*Approximate fan rpm shown.


Indicates standard motor and drive package.
** Indicates alternate drive package only.

64

11/2
765
860
988
860
988
860
1010
1062
1015
1062

MOTOR PULLEY TURNS OPEN


2
21/2
3
31/2
740
715
690
665
835
810
785
760
970
952
933
915
835
810
785
760
970
952
933
915
835
810
785
760
985
960
935
910
1037
1012
987
962
990
970
950
925
1037
1012
987
962

4
635
735
897
735
897
735
885
937
905
937

41/2
615
710
878
710
878
710
860
912
880
912

5
590
685
860
685
860
685
835
887
860
887

Indicates high-static motor and drive package.


***Indicates alternate motor and drive package.

51 / 2

862

862

830

830

EVAPORATOR-FAN MOTOR PERFORMANCE 50TFF004-014


UNIT
50TFF

EVAPORATOR-FAN
MOTOR
Standard

004

Alternate

Standard

005

Alternate

High Static

Standard

006

Alternate

High Static

Standard
007
High Static

Standard,
Alternate
008
High Static

Standard
009
High Static

Standard

012

Alternate

High Static

Standard
014
Alternate

MAXIMUM ACCEPTABLE
CONTINUOUS BHP*

MAXIMUM ACCEPTABLE
OPERATING WATTS

0.34

440

1.20

1000

2.40

2120

0.75

850

1.20

1000

2.40

2120

1.20

1340

1.30/2.40

2120

2.90

2562

2.40

2120

2.90

2562

2.40

2120

3.70

3313

2.40

2120

3.70

3313

2.40

2120

2.90

2615

5.25

4400

3.70

3313

5.25

4400

LEGEND
Bhp Brake Horsepower
*Extensive motor and electrical testing on these units ensures that the full horsepower range of the motors can be utilized with confidence. Using your fan
motors up to the horsepower ratings shown in this table will not result in nuisance tripping or premature motor failure. Unit warranty will not be affected.
Single-phase/three-phase.

MAXIMUM
AMP DRAW
2.8
1.3
1.3
4.9
2.1
2.1
6.0
3.0
3.0
3.5
1.8
1.8
4.9
2.1
2.1
6.0
3.0
3.0
5.9
3.2
3.2
10.1/6.7
3.0
3.0
8.6
3.9
3.9
6.7
3.0
3.0
8.6
3.9
3.9
6.7
3.0
3.0
12.2
5.5
5.5
6.7
3.0
3.0
12.2
5.5
5.5
6.7
3.0
3.0
8.6
3.9
3.9
17.3
8.5
8.5
12.2
5.5
5.5
17.3
8.5
8.5

50TFF

High Static

UNIT
VOLTAGE
208/230
460
575
208/230
460
575
208/230
460
575
208/230
460
575
208/230
460
575
208/230
460
575
208/230
460
575
208/230
460
575
208/230
460
575
208/230
460
575
208/230
460
575
208/230
460
575
208/230
460
575
208/230
460
575
208/230
460
575
208/230
460
575
208/230
460
575
208/230
460
575
208/230
460
575
208/230
460
575

NOTES:
1. All indoor-fan motors 5 hp and larger meet the minimum efficiency requirements as established by the Energy Policy Act of 1992 (EPACT) effective
October 24, 1997.
2. High-static motor not available on single-phase units.

65

Performance data 50TFF (cont)


ACCESSORY HEATER STATIC PRESSURE* (in. wg) 50TFF004-007
COMPONENT
1 Heater Module
2 Heater Modules

CFM
900
0.05
0.15

1200
0.07
0.16

1400
0.09
0.16

1600
0.09
0.16

1800
0.10
0.17

2000
0.11
0.17

2200
0.11
0.17

2400
0.12
0.18

2600
0.13
0.18

3000
0.15
0.19

6000
0.16
0.21

6250
0.17
0.20

50TFF

*The static pressure must be added to external static pressure. The sum and the evaporator
entering-air cfm should then be used in conjunction with the Fan Performance tables to determine blower rpm and watts.

ACCESSORY HEATER STATIC PRESSURE* (in. wg) 50TFF008-014


COMPONENT
1 Heater Module
2 Heater Modules

CFM
2250
0.02
0.03

2500
0.03
0.05

3000
0.05
0.07

3500
0.07
0.09

4000
0.08
0.12

4500
0.10
0.14

5000
0.12
0.16

5500
0.14
0.19

*The static pressure must be added to external static pressure. The sum and the evaporator
entering-air cfm should then be used in conjunction with the Fan Performance tables to determine blower rpm and watts.

ACCESSORY/FIOP ECONOMI$ER IV AND ECONOMI$ER2 STATIC PRESSURE* (in. wg) 50TFF004-007


COMPONENT
Vertical EconoMi$er IV and EconoMi$er2
Horizontal EconoMi$er IV and EconoMi$er2
LEGEND
FIOP Factory-Installed Option

CFM
1250
0.045

1500
0.065

1750
0.08
0.1

2000
0.12
0.125

2250
0.145
0.15

2500
0.175
0.18

2750
0.22
0.225

3000
0.255
0.275

*The static pressure must be added to external static pressure. The


sum and the evaporator entering-air cfm should be used in conjunction
with the Fan Performance tables to determine indoor blower rpm and
watts.

ACCESSORY/FIOP ECONOMI$ER IV AND ECONOMI$ER2 STATIC PRESSURE* (in. wg) 50TFF008-014


CFM
2250 2500 2750 3000 3250 3500 3750 4000 4250 4500 4750 5000 5250 6250
Vertical EconoMi$er IV and EconoMi$er2
0.06 0.075 0.09 0.115 0.13 0.15 0.17 0.195 0.22 0.25 0.285 0.325 0.36

Horizontal EconoMi$er IV and EconoMi$er2


0.1
0.125 0.15 0.18 0.21 0.25 0.275 0.3 0.34 0.388

COMPONENT

LEGEND
FIOP Factory-Installed Option

66

*The static pressure must be added to external static pressure. The


sum and the evaporator entering-air cfm should be used in conjunction
with the Fan Performance tables to determine indoor blower rpm and
watts.

HORIZONTAL ECONOMI$ER IV AND ECONOMI$ER2


PERFORMANCE DATA (50TFF004-014)

VERTICAL ECONOMI$ER IV AND ECONOMI$ER2


PERFORMANCE DATA (50TFF004-014)
5000

2500
2000

3000

3-6 Ton

2000

7.5-12.5 Ton

FLOW (cfm)

FLOW (cfm)

4000

1000

1500
1000

50TFF

500

0
0

0.1

0.2

0.3

0.4

0.5
0

STATIC PRESSURE (in. wg)

VERTICAL POWER EXHAUST PERFORMANCE

0.1

0.2

0.3

0.4

0.5

STATIC PRESSURE (in. wg)

2500

2500
Flow in cubic feet per minute (cfm)

FLOW IN CUBIC FEET PER MINUTE (cfm)

HORIZONTAL POWER EXHAUST PERFORMANCE

2000
3-6 Ton

1500

7 1/2 - 12 1/2 Ton


1000
500
0
0.15

0.05

0.25

2000

1500
3-6 Ton
7-12 1/2 Ton
1000

500

STATIC PRESSURE (in. wg)

0
0.05"

BAROMETRIC RELIEF FLOW CAPACITY

0.15"

0.25"

Static Pressure (in. wg)

Flow in cubic feet per minute (cfm)

FLOW IN CUBIC FEET PER MINUTE (cfm)

BAROMETRIC RELIEF CAPACITY

30
25
20
3-6 Ton
7 1/2-12 1/2 Ton

15
10
5
0
0.13

0.20 0.22

0.25

0.30 0.35 0.40

0.45

30
25
20
3-6 Ton

15

7-12 1/2 Ton

10
5
0
0.1"

0.50

0.2"

0.3"

0.4"

0.5"

Static Pressure (in. wg)

STATIC PRESSURE (in. wg)

OUTDOOR AIR DAMPER LEAKAGE

OUTDOOR AIR DAMPER LEAKAGE

OUTDOOR SOUND DATA (Total Unit) 50TFF004-014


UNIT
50TFF

SOUND RATING
(dB)

A-WEIGHTED
(dB)

004-007
008,009
012
014

81
87
88
87

80.5
86.4
87.6
86.4

63
56.8
83.2
97.6
83.7

125
75.8
87.4
90.4
87.2

250
72.4
83.5
85.7
83.4

SOUND POWER
Octave Bands
500
1000
72.9
74.8
82.8
83.0
84.8
83.9
82.8
83.0

2000
75.4
77.7
77.5
77.7

4000
71.3
71.8
71.3
71.8

8000
69.1
67.0
65.8
67.0

67

Performance data 50TFF (cont)


ELECTRIC HEATING CAPACITIES
UNIT
VOLTAGE
(60 Hz)

UNIT
50TFF

ACCESSORY
kW

50TFF

208/230
(single phase)

004

208/230
(3 phase)

460
(3 phase)

208/230
(single phase)

005

208/230
(3 phase)
460
(3 phase)

208/230
(single phase)

208/230
(3 phase)

006

460
(3 phase)

4.4
6.5
8.7
10.5
13.0*
4.4
6.5
8.7
10.5
16.0
6.0
8.8
11.5
14.0
4.4
8.7
13.0*
17.4*
21.0*
6.5
8.7
16.0
21.0*
6.0
11.5
14.0*
23.0*
6.5
8.7
13.0*
17.4*
21.0*
6.5
10.5
16.0
21.0*
26.5*
6.0
11.5
14.0
23.0*
25.0*

ELECTRIC HEATING CAPACITIES (cont)

ACCESSORY
SINGLE POINT
BOX PART NO.
CRSINGLE---A00

004**

004**
004**
004**

002**

004**
004**
004**

002**
002**

UNIT
50TFF

UNIT
VOLTAGE
(60 Hz)
208/230
(3 phase)

007
460
(3 phase)

208/230
(3 phase)
008,009
460
(3 phase)
575
(3 phase)
208/230
(3 phase)

012,014

460
(3 phase)
575
(3 phase)

ACCESSORY
kW
6.5
10.5
16.0
21.0*
26.5*
6.0
11.5
14.0
23.0*
25.5*
10.4
16.0
24.8
32.0*
42.4*
13.9
16.5
27.8
33.0
41.7*
17.0
34.0
10.4
16.0
32.0
42.4*
50.0*
16.5
27.8
33.0
41.7*
50.0*
17.0
34.0
51.0*

ACCESSORY
SINGLE POINT
BOX PART NO.
CRSINGLE---A00

002**
002**

006
006
007
007**
009**
006
006
006
006
008**
006
006
011
011
012
015**
015**
011
011
011
014**
014**
011
011
014**

NOTES:
1. The kW ratings shown above are at 240, 480, and 600 v. Use the
Multiplication Factors table below to determine heater capacity for
your particular voltage.
2. Heaters are not available for size 004-007, 575-v units.

*Two heater packages required to provide kW indicated.


Single-point package is used for units with standard motor and without
convenience outlet. For units with alternate motor, high-static motor,
and/or convenience outlet, please contact Application Engineering.
**A single-point kit is required with each unit to meet UL requirements
when using electric heat. (CRSINGLE006A00 and CRSINGLE011A00
kits to not require fuses per NEC.)
012 for 50TFF014.

MULTIPLICATION FACTORS
HEATER RATING
VOLTAGE
240
480
600

200
0.694

208
0.751

230
0.918

240
1.000

ACTUAL HEATER VOLTAGE


380
440
460

0.626
0.840
0.918

NOTE: The following equation converts kW of heat energy to Btuh: kW


x 3.412 = Btuh.

MINIMUM HEATING AIRFLOW


UNIT 50TFF
004
005
006
007
008
009
012
014

68

CFM
900
1200
1500
1800
2250
2550
3000
3750

480

1.000

550

0.840

EXAMPLE: 32.0 kW (at 240 v) heater on 208 v


= 32.0 (.751 mult factor)
= 24.0 kW capacity at 208 v.

575

0.918

600

1.000

Electrical data 50TFF


ELECTRICAL DATA UNITS WITHOUT CONVENIENCE OUTLET
UNIT
50TFF

NOMINAL
V-PH-Hz

IFM
TYPE

VOLTAGE
RANGE
Min

Max

COMPRESSOR
(ea)
Qty

RLA

LRA

OFM (ea)
Qty

Hp

FLA

STD
208/230-1-60

3.5
187

254

16.2

96

1/
4

1.4

ALT

4.9

STD

3.5

ALT

HEATER
MODEL NO.
CRHEATER---A00

187

254

10.2

75

1/4

1.4

4.9

004

460-3-60

HIGH

5.2

STD

1.3

ALT

414

508

4.4

40

1/4

0.8

HIGH

575-3-60

STD
ALT
HIGH

2.1

2.6

518

632

3.7

31

1/4

0.8

1.3
2.1
2.6

LEGEND
FLA
HACR
IFM
LRA
MCA
MOCP
NEC
OFM
RLA

Full Load Amps


Heating, Air Conditioning and Refrigeration
Indoor (Evaporator) Fan Motor
Locked Rotor Amps
Minimum Circuit Amps
Maximum Overcurrent Protection
National Electrical Code
Outdoor (Condenser) Fan Motor
Rated Load Amps

*Used to determine minimum disconnect per NEC.


Fuse or HACR circuit breaker.

NONE
001
002
003
004
002 and 002
NONE
001
002
003
004
002 and 002
NONE
001
002
003
004
005
NONE
001
002
003
004
005
NONE
001
002
003
004
005
NONE
006
007
008
009
NONE
006
007
008
009
NONE
006
007
008
009
NONE
NONE
NONE

ELECTRIC HEAT
Nominal
kW
/
3.3/ 4.4
4.9/ 6.5
6.4/ 8.7
7.9/10.5
9.8/13.0
/
3.3/ 4.4
4.9/ 6.5
6.5/ 8.7
7.9/10.5
9.8/13.0
/
3.3/ 4.4
4.9/ 6.5
6.5/ 8.7
7.9/10.5
12.2/16.0
/
3.3/ 4.4
4.9/ 6.5
6.5/ 8.7
7.9/10.5
12.3/16.0
/
3.3/ 4.4
4.9/ 6.5
6.5/ 8.7
7.9/10.5
12.3/16.0

6.0
8.8
11.5
14.0

6.0
8.8
11.5
14.0

6.0
8.8
11.5
14.0

DISCONNECT
SIZE

POWER SUPPLY

FLA

MCA

MOCP*

FLA

LRA

SINGLE POINT
BOX P/N
CRSINGLE---A00

/
15.9/18.3
23.5/27.1
31.4/36.3
37.9/43.8
46.9/54.2
/
15.9/18.3
23.5/27.1
31.4/36.3
37.9/43.8
46.9/54.2
/
9.2/10.6
13.6/15.6
18.1/20.9
21.9/25.3
33.4/38.4
/
9.2/10.6
13.6/15.6
18.1/20.9
21.9/25.3
33.4/38.4
/
9.2/10.6
13.6/15.6
18.1/20.9
21.9/25.3
33.4/38.4

7.2
10.6
13.8
16.8

7.2
10.6
13.8
16.8

7.2
10.6
13.8
16.8

25.2/25.2
25.2/27.3
33.7/38.2
43.6/49.7
51.8/59.1
63.0/72.1
26.6/26.6
26.6/29.0
35.5/40.0
45.4/51.4
53.5/60.8
64.8/73.8
17.7/17.7
17.7/17.7
21.3/23.9
27.0/30.5
31.7/35.9
46.1/52.4
19.1/19.1
19.1/19.4
23.1/25.7
28.8/32.3
33.5/37.7
47.8/54.2
19.4/19.4
19.4/19.7
23.4/26.0
29.2/32.7
33.9/38.1
48.2/54.6
7.6
10.6
14.9
18.9
22.7
8.4
11.6
15.9
19.9
23.7
8.9
12.3
16.5
20.5
24.3
5.5
6.0
6.3

30/30
30/30
35/40
45/50
60/60
70/80
35/35
35/35
40/40
50/60
60/70
70/80
25/25
25/25
25/25
30/35
35/40
50/60
25/25
25/25
25/30
30/35
35/40
50/60
25/25
25/25
30/30
30/35
35/40
50/60
15
15
15
20
25
15
15
20
20
25
15
15
20
25
25
15
15
15

24/24
24/25
31/35
40/46
48/54
58/66
26/26
26/27
33/37
42/47
49/56
60/68
17/17
17/17
20/22
25/28
29/33
42/48
19/19
19/19
21/24
26/30
31/35
44/50
19/19
19/19
22/24
27/30
31/35
44/50
7
10
14
17
21
8
11
15
18
22
9
11
15
19
22
6
7
7

106/106
106/106
106/106
106/106
106/106
106/106
111/111
111/111
111/111
111/111
111/111
111/111
85/ 85
85/ 85
85/ 85
85/ 85
85/ 85
85/ 85
90/ 90
90/ 90
90/ 90
90/ 90
90/ 90
90/ 90
109/109
109/109
109/109
109/109
109/109
109/109
44
45
45
45
45
48
48
48
48
48
57
57
57
57
57
34
37
56

004

004
004

50TFF

208/230-3-60

IFM
FLA

Determine maximum deviation from average voltage.


(AB) 457 452 = 5 v
(BC) 464 457 = 7 v
(AC) 457 455 = 2 v
Maximum deviation is 7 v.
Determine percent of voltage imbalance.
% Voltage Imbalance = 100 x

7
457

= 1.53%
This amount of phase imbalance is satisfactory as it is below the maximum allowable 2%.
IMPORTANT: If the supply voltage phase imbalance is more than 2%, contact your local electric utility company immediately.

NOTES:
1. In compliance with NEC requirements for multimotor and combination load equipment (refer to NEC
Articles 430 and 440), the overcurrent protective device for the unit shall be fuse or HACR breaker.
Canadian units may be fuse or circuit breaker.
2. Unbalanced 3-Phase Supply Voltage
Never operate a motor where a phase imbalance in supply voltage is greater than 2%. Use the following formula to determine the percent of voltage imbalance.
% Voltage Imbalance
= 100 x

max voltage deviation from average voltage


average voltage

Example: Supply voltage is 460-3-60.


AB = 452 v
BC = 464 v
AC = 455 v
Average Voltage =
=

452 + 464 + 455


3
1371
3

= 457

3. For units with power exhaust: If a single power source is to be used, size wire to include power
exhaust MCA and MOCP. Check MCA and MOCP when power exhaust is powered through the
unit (must be in accordance with NEC and/or local codes). Determine the new MCA including the
power exhaust using the following formula:
MCA New = MCA unit only + MCA of Power Exhaust
For example, using a 50TFF006---5 unit with MCA = 28.9 and MOCP = 35, with
CRPWREXH030A01 power exhaust.
MCA New = 28.9 amps + 1.6 amps = 30.5 amps
If the new MCA does not exceed the published MOCP, then MOCP would not change. The MOCP
in this example is 35 amps, the MCA New is below 35, therefore the MOCP is acceptable. If MCA
New is larger than the published MOCP, raise the MOCP to the next larger size. For separate
power, the MOCP for the power exhaust will be 15 amps per NEC.
POWER EXHAUST
PART NO.

MCA
(230 v)

MCA
(460 v)

MCA
(575 v)

CRPWREXH021A01
CRPWREXH022A01
CRPWREXH023A01
CRPWREXH028A01
CRPWREXH029A01
CRPWREXH030A01

N/A
3.4
N/A
1.7
N/A
1.6

0.68
N/A
1.4
N/A
0.7
N/A

N/A
1.32
N/A
0.68
N/A
0.64

MOCP
(for separate
power source)
15
15
15
15
15
15

69

Electrical data 50TFF (cont)


ELECTRICAL DATA UNITS WITHOUT CONVENIENCE OUTLET (cont)
UNIT
50TFF

NOMINAL
V-PH-Hz

IFM
TYPE

VOLTAGE
RANGE
Min

Max

COMPRESSOR
(ea)
Qty

RLA

LRA

OFM (ea)
Qty

Hp

FLA

STD

50TFF

208/230-1-60

208/230-3-60

IFM
FLA

3.5
187

254

23.3

118

1/

1.4

ALT

4.9

STD

3.5

ALT

187

254

15.4

90

1/ 4

1.4

4.9

005

460-3-60

HIGH

5.2

STD

1.8

ALT

414

508

8.3

45

1/ 4

0.8

HIGH

575-3-60

STD
ALT
HIGH

2.1

2.6

518

632

6.4

36

1/ 4

0.8

1.8
2.1
2.6

HEATER
MODEL NO
CRHEATER---A00
NONE
001
003
002 and 002
003 and 003
004 and 004
NONE
001
003
002 and 002
003 and 003
004 and 004
NONE
002
003
005
004 and 004
NONE
002
003
005
004 and 004
NONE
002
003
005
004 and 004
NONE
006
008
009
008 and 008
NONE
006
008
009
008 and 008
NONE
006
008
009
008 and 008
NONE
NONE
NONE

LEGEND
FLA
HACR
IFM
LRA
MCA
MOCP
NEC
OFM
RLA

Full Load Amps


Heating, Air Conditioning and Refrigeration
Indoor (Evaporator) Fan Motor
Locked Rotor Amps
Minimum Circuit Amps
Maximum Overcurrent Protection
National Electrical Code
Outdoor (Condenser) Fan Motor
Rated Load Amps

*Used to determine minimum disconnect per NEC.


Fuse or HACR circuit breaker.

ELECTRIC HEAT
Nominal
kW
/
3.3/ 4.4
6.5/ 8.7
9.3/13.0
13.1/17.4
15.8/21.0
/
3.3/ 4.4
6.5/ 8.7
9.3/13.0
13.1/17.4
15.8/21.0
/
4.9/ 6.5
6.5/ 8.7
12.0/16.0
15.8/21.0
/
4.9/ 6.5
6.5/ 8.7
12.0/16.0
15.8/21.0
/
4.9/ 6.5
6.5/ 8.7
12.0/16.0
15.8/21.0

6.0
11.5
14.0
23.0

6.0
11.5
14.0
23.0

6.0
11.5
14.0
23.0

DISCONNECT
SIZE

POWER SUPPLY

FLA

MCA

MOCP*

FLA

LRA

SINGLE POINT
BOX P/N
CRSINGLE---A00

/
15.9/18.3
31.4/36.3
46.9/54.2
62.8/72.5
75.8/87.5
/
15.9/18.3
31.4/36.3
46.9/54.2
62.8/72.5
75.8/87.5
/
13.6/15.6
18.1/20.9
33.4/38.4
43.8/50.5
/
13.6/15.6
18.1/20.9
33.4/38.4
43.8/50.5
/
13.6/15.6
18.1/20.9
33.4/38.4
43.8/50.5

7.2
13.8
16.8
27.7

7.2
13.8
16.8
27.7

7.2
13.8
16.8
27.7

34.0/ 34.0
34.0/ 34.0
43.6/ 49.7
63.0/ 72.1
82.9/ 95.0
99.2/113.8
35.4/ 35.4
35.4/ 35.4
45.4/ 51.4
64.8/ 73.8
84.7/ 96.8
100.9/115.5
24.2/ 24.2
24.2/ 24.2
27.0/ 30.5
46.1/ 52.4
59.1/ 67.5
25.6/ 25.6
25.6/ 25.7
28.8/ 32.3
47.8/ 54.2
60.8/ 69.3
25.9/ 25.9
25.9/ 26.0
29.2/ 32.7
48.2/ 54.6
61.2/ 69.6
13.0
13.0
19.5
23.3
36.8
13.3
13.3
19.9
23.7
37.2
13.8
13.8
20.5
24.3
37.8
9.2
9.3
9.7

40/ 40
40/ 40
45/ 50
70/ 80
90/100
100/125
45/ 45
45/ 45
50/ 60
70/ 80
90/100
110/125
30/ 30
30/ 30
30/ 35
50/ 60
60/ 70
30/ 30
30/ 30
30/ 35
50/ 60
70/ 70
30/ 30
30/ 30
30/ 35
50/ 60
70/ 70
20
20
20
25
40
20
20
20
25
40
20
20
25
25
40
15
15
15

32/ 32
32/ 32
40/ 46
58/ 66
76/ 87
91/105
34/ 34
34/ 34
42/ 47
60/ 68
78/ 89
93/106
23/ 23
23/ 23
25/ 28
42/ 48
54/ 62
25/ 25
25/ 25
26/ 30
44/ 50
56/ 64
25/ 25
25/ 25
27/ 30
44/ 50
56/ 64
13
13
18
21
34
13
13
18
22
34
13
13
19
22
35
10
10
10

129/129
129/129
129/129
129/129
129/129
129/129
133/133
133/133
133/133
133/133
133/133
133/133
101/101
101/101
101/101
101/101
101/101
105/105
105/105
105/105
105/105
105/105
124/124
124/124
124/124
124/124
124/124
51
51
51
51
51
53
53
53
53
53
62
62
62
62
62
41
42
49

004
004
004

004
004
004

002

002

002

Determine maximum deviation from average voltage.


(AB) 457 452 = 5 v
(BC) 464 457 = 7 v
(AC) 457 455 = 2 v
Maximum deviation is 7 v.
Determine percent of voltage imbalance.
% Voltage Imbalance = 100 x

7
457

= 1.53%
This amount of phase imbalance is satisfactory as it is below the maximum allowable 2%.
IMPORTANT: If the supply voltage phase imbalance is more than 2%, contact your local electric utility company immediately.

NOTES:
1. In compliance with NEC requirements for multimotor and combination load equipment (refer to NEC
Articles 430 and 440), the overcurrent protective device for the unit shall be fuse or HACR breaker.
Canadian units may be fuse or circuit breaker.
2. Unbalanced 3-Phase Supply Voltage
Never operate a motor where a phase imbalance in supply voltage is greater than 2%. Use the following formula to determine the percent of voltage imbalance.
% Voltage Imbalance
= 100 x

max voltage deviation from average voltage


average voltage

Example: Supply voltage is 460-3-60.


AB = 452 v
BC = 464 v
AC = 455 v
Average Voltage =
=

452 + 464 + 455


3
1371
3

= 457

70

3. For units with power exhaust: If a single power source is to be used, size wire to include power
exhaust MCA and MOCP. Check MCA and MOCP when power exhaust is powered through the
unit (must be in accordance with NEC and/or local codes). Determine the new MCA including the
power exhaust using the following formula:
MCA New = MCA unit only + MCA of Power Exhaust
For example, using a 50TFF006---5 unit with MCA = 28.9 and MOCP = 35, with
CRPWREXH030A001 power exhaust.
MCA New = 28.9 amps + 1.6 amps = 30.5 amps
If the new MCA does not exceed the published MOCP, then MOCP would not change. The MOCP
in this example is 35 amps, the MCA New is below 35, therefore the MOCP is acceptable. If MCA
New is larger than the published MOCP, raise the MOCP to the next larger size. For separate
power, the MOCP for the power exhaust will be 15 amps per NEC.
POWER EXHAUST
PART NO.

MCA
(230 v)

MCA
(460 v)

MCA
(575 v)

CRPWREXH021A01
CRPWREXH022A01
CRPWREXH023A01
CRPWREXH028A01
CRPWREXH029A01
CRPWREXH030A01

N/A
3.4
N/A
1.7
N/A
1.6

0.68
N/A
1.4
N/A
0.7
N/A

N/A
1.32
N/A
0.68
N/A
0.64

MOCP
(for separate
power source)
15
15
15
15
15
15

ELECTRICAL DATA UNITS WITHOUT CONVENIENCE OUTLET (cont)


UNIT
50TFF

NOMINAL
V-PH-Hz

IFM
TYPE

VOLTAGE
RANGE
Min

Max

COMPRESSOR
(ea)
Qty

RLA

LRA

OFM (ea)
Qty

Hp

FLA

STD
208/230-1-60

5.9
187

254

28.8

147

1/

1.4

ALT

6.6

STD

5.9

ALT

187

254

16

114

1/ 4

1.4

5.2

006

460-3-60

HIGH

7.5

STD

3.1

ALT

414

508

7.4

64

1/

0.8

HIGH

575-3-60

STD
ALT
HIGH

2.6

3.4

518

632

6.2

52

1/ 4

0.8

3.1
2.6
3.4

HEATER
MODEL NO.
CRHEATER---A00
NONE
002
003
002 and 002
003 and 003
004 and 004
NONE
002
003
002 and 002
003 and 003
004 and 004
NONE
002
004
005
004 and 004
004 and 005
NONE
002
004
005
004 and 004
004 and 005
NONE
002
004
005
004 and 004
004 and 005
NONE
006
008
009
008 and 008
008 and 009
NONE
006
008
009
008 and 008
008 and 009
NONE
006
008
009
008 and 008
008 and 009
NONE
NONE
NONE

LEGEND
FLA
HACR
IFM
LRA
MCA
MOCP
NEC
OFM
RLA

Full Load Amps


Heating, Air Conditioning and Refrigeration
Indoor (Evaporator) Fan Motor
Locked Rotor Amps
Minimum Circuit Amps
Maximum Overcurrent Protection
National Electrical Code
Outdoor (Condenser) Fan Motor
Rated Load Amps

*Used to determine minimum disconnect per NEC.


Fuse or HACR circuit breaker.

ELECTRIC HEAT
Nominal
kW
/
4.9/ 6.5
6.5/ 8.7
9.8/13.0
13.1/17.4
15.8/21.0
/
4.9/ 6.5
6.5/ 8.7
9.8/13.0
13.1/17.4
15.8/21.0
/
4.9/ 6.5
7.9/10.5
12.0/16.0
15.8/21.0
19.9/26.5
/
4.9/ 6.5
7.9/10.5
12.0/16.0
15.8/21.0
19.9/26.5
/
4.9/ 6.5
7.9/10.5
12.0/16.0
15.8/21.0
19.9/26.5

6.0
11.5
14.0
23.0
25.0

6.0
11.5
14.0
23.0
25.0

6.0
11.5
14.0
23.0
25.0

DISCONNECT
SIZE

POWER SUPPLY

FLA

MCA

MOCP*

FLA

LRA

/
23.5/27.1
31.4/36.3
46.9/54.2
62.8/72.5
75.8/87.5
/
23.5/27.1
31.4/36.3
46.9/54.2
62.8/72.5
75.8/87.5
/
13.6/15.6
21.9/25.3
33.4/38.4
43.8/50.5
55.2/63.8
/
13.6/15.6
21.9/25.3
33.4/38.4
43.8/50.5
55.2/63.8
/
13.6/15.6
21.9/25.3
33.4/38.4
43.8/50.5
55.2/63.8

7.2
13.8
16.8
27.7
30.1

7.2
13.8
16.8
27.7
30.1

7.2
13.8
16.8
27.7
30.1

43.3/ 43.3
43.3/ 43.3
46.6/ 52.7
66.0/ 75.1
85.9/ 98.0
102.2/116.8
44.0/ 44.0
44.0/ 44.0
47.5/ 53.6
66.9/ 76.0
86.8/ 98.9
103.0/117.6
27.3/ 27.3
27.3/ 27.3
34.7/ 38.9
49.1/ 55.4
62.1/ 70.5
76.4/ 87.1
26.6/ 26.6
26.6/ 26.6
33.9/ 38.1
48.2/ 54.6
61.2/ 69.6
75.6/ 86.2
28.9/ 28.9
28.9 28.9
36.7/ 40.9
51.1/ 57.4
64.1/ 72.5
78.4/ 89.1
13.2
13.2
21.2
24.9
38.5
41.5
13.5
13.5
21.5
25.3
38.8
41.8
13.5
13.5
21.5
25.3
38.8
41.8
9.7
9.9
9.9

60/ 60
60/ 60
50/ 60
70/ 80
90/100
110/125
60/ 60
60/ 60
50/ 60
70/ 80
90/100
110/125
35/ 35
35/ 35
40/ 40
50/ 60
70 80
80/ 90
35/ 35
35/ 35
35/ 40
50/ 60
70/ 70
80/ 90
35/ 35
35/ 35
40/ 45
60/ 60
70/ 80
80/ 90
20
20
25
25
40
45
20
20
25
30
40
45
20
20
25
30
40
45
15
15
15

42/ 42
42/ 42
43/ 48
61/ 69
79/ 90
94/107
42/ 42
42/ 42
44/ 49
62/ 70
80/ 91
95/108
27/ 27
27/ 27
32/ 36
45/ 51
57/ 65
70/ 80
26/ 26
26/ 26
31/ 35
44/ 50
56/ 64
70/ 79
29/ 29
29/ 29
34/ 38
47/ 53
59/ 67
72/ 82
13
13
19
23
35
38
13
13
20
23
36
38
13
13
20
23
36
38
11
11
11

161/161
161/161
161/161
161/161
161/161
161/161
184/184
184/184
184/184
184/184
184/184
184/184
128/128
128/128
128/128
128/128
128/128
128/128
148/148
148/148
148/148
148/148
148/148
148/148
174/174
174/174
174/174
174/174
174/174
174/174
71
72
72
72
72
72
81
81
81
81
81
81
93
94
94
94
94
94
58
65
75

SINGLE POINT
BOX P/N
CRSINGLE---A00

004
004
004

004
004
004

002
002

002
002

002
002

50TFF

208/230-3-60

IFM
FLA

Determine maximum deviation from average voltage.


(AB) 457 452 = 5 v
(BC) 464 457 = 7 v
(AC) 457 455 = 2 v
Maximum deviation is 7 v.
Determine percent of voltage imbalance.
% Voltage Imbalance = 100 x

7
457

= 1.53%
This amount of phase imbalance is satisfactory as it is below the maximum allowable 2%.
IMPORTANT: If the supply voltage phase imbalance is more than 2%, contact your local electric utility company immediately.

NOTES:
1. In compliance with NEC requirements for multimotor and combination load equipment (refer to NEC
Articles 430 and 440), the overcurrent protective device for the unit shall be fuse or HACR breaker.
Canadian units may be fuse or circuit breaker.
2. Unbalanced 3-Phase Supply Voltage
Never operate a motor where a phase imbalance in supply voltage is greater than 2%. Use the following formula to determine the percent of voltage imbalance.
% Voltage Imbalance
= 100 x

max voltage deviation from average voltage


average voltage

Example: Supply voltage is 460-3-60.


AB = 452 v
BC = 464 v
AC = 455 v
Average Voltage =
=

452 + 464 + 455


3
1371
3

= 457

3. For units with power exhaust: If a single power source is to be used, size wire to include power
exhaust MCA and MOCP. Check MCA and MOCP when power exhaust is powered through the
unit (must be in accordance with NEC and/or local codes). Determine the new MCA including the
power exhaust using the following formula:
MCA New = MCA unit only + MCA of Power Exhaust
For example, using a 50TFF006---5 unit with MCA = 28.9 and MOCP = 35, with
CRPWREXH030A01 power exhaust.
MCA New = 28.9 amps + 1.6 amps = 30.5 amps
If the new MCA does not exceed the published MOCP, then MOCP would not change. The MOCP
in this example is 35 amps, the MCA New is below 35, therefore the MOCP is acceptable. If MCA
New is larger than the published MOCP, raise the MOCP to the next larger size. For separate
power, the MOCP for the power exhaust will be 15 amps per NEC.
POWER EXHAUST
PART NO.

MCA
(230 v)

MCA
(460 v)

MCA
(575 v)

CRPWREXH021A01
CRPWREXH022A01
CRPWREXH023A01
CRPWREXH028A01
CRPWREXH029A01
CRPWREXH030A01

N/A
3.4
N/A
1.7
N/A
1.6

0.68
N/A
1.4
N/A
0.7
N/A

N/A
1.32
N/A
0.68
N/A
0.64

MOCP
(for separate
power source)
15
15
15
15
15
15

71

Electrical data 50TFF (cont)


ELECTRICAL DATA UNITS WITHOUT CONVENIENCE OUTLET (cont)
UNIT
50TFF

NOMINAL
V-PH-Hz

IFM
TYPE

VOLTAGE
RANGE
Min

Max

COMPRESSOR
(ea)
Qty

RLA

LRA

OFM (ea)
Qty

Hp

FLA

STD

50TFF

208/230-3-60

IFM
FLA

HEATER
MODEL NO.
CRHEATER---A00

5.2
187

254

20.6

146

1/

1.4

HIGH

7.5

STD

2.6

007

460-3-60

414

508

9.5

73

1/ 4

0.9

HIGH

575-3-60

STD
HIGH

3.4

518

632

7.6

62

1/

0.9

2.6
3.4

LEGEND
FLA
HACR
IFM
LRA
MCA
MOCP
NEC
OFM
RLA

Full Load Amps


Heating, Air Conditioning and Refrigeration
Indoor (Evaporator) Fan Motor
Locked Rotor Amps
Minimum Circuit Amps
Maximum Overcurrent Protection
National Electrical Code
Outdoor (Condenser) Fan Motor
Rated Load Amps

*Used to determine minimum disconnect per NEC.


Fuse or HACR circuit breaker.

NONE
002
004
005
004 and 004
004 and 005
NONE
002
004
005
004 and 004
004 and 005
NONE
006
008
009
008 and 008
008 and 009
NONE
006
008
009
008 and 008
008 and 009
NONE
NONE

ELECTRIC HEAT
Nominal
kW
/
4.9/ 6.5
7.9/10.5
12.0/16.0
15.8/21.0
19.9/26.5
/
4.9/ 6.5
7.9/10.5
12.0/16.0
15.8/21.0
19.9/26.5

6.0
11.5
14.0
23.0
25.5

6.0
11.5
14.0
23.0
25.5

DISCONNECT
SIZE

POWER SUPPLY

FLA

MCA

MOCP*

FLA

LRA

SINGLE POINT
BOX P/N
CRSINGLE---A00

/
13.6/15.6
21.9/25.3
33.4/38.4
43.8/50.5
55.2/63.8
/
13.6/15.6
21.9/25.3
33.4/38.4
43.8/50.5
55.2/63.8

7.2
13.8
16.8
27.7
30.7

7.2
13.8
16.8
27.7
30.7

32.4/32.4
32.4/32.4
33.9/38.1
48.2/54.6
61.2/69.6
75.6/86.2
34.7/34.7
34.7/34.7
36.7/40.9
51.1/57.4
64.1/72.5
78.4/89.1
15.4
15.4
20.5
24.3
37.8
41.6
16.2
16.2
21.5
25.3
38.8
42.6
11.4
11.9

40/40
40/40
35/40
50/60
70/70
80/90
40/40
40/40
40/45
60/60
70/80
80/90
20
20
25
25
40
45
20
20
25
30
40
45
15
15

31/31
31/31
31/35
44/50
56/64
70/79
34/34
34/34
34/38
47/53
59/67
72/82
15
15
19
22
35
38
16
16
20
23
36
39
12
13

180/180
180/180
180/180
180/180
180/180
180/180
205/205
205/205
205/205
205/205
205/205
205/205
90
90
90
90
90
90
103
103
103
103
103
103
75
86

002
002

002
002

Determine maximum deviation from average voltage.


(AB) 457 452 = 5 v
(BC) 464 457 = 7 v
(AC) 457 455 = 2 v
Maximum deviation is 7 v.
Determine percent of voltage imbalance.
% Voltage Imbalance = 100 x

7
457

= 1.53%
This amount of phase imbalance is satisfactory as it is below the maximum allowable 2%.
IMPORTANT: If the supply voltage phase imbalance is more than 2%, contact your local electric utility company immediately.

NOTES:
1. In compliance with NEC requirements for multimotor and combination load equipment (refer to NEC
Articles 430 and 440), the overcurrent protective device for the unit shall be fuse or HACR breaker.
Canadian units may be fuse or circuit breaker.
2. Unbalanced 3-Phase Supply Voltage
Never operate a motor where a phase imbalance in supply voltage is greater than 2%. Use the following formula to determine the percent of voltage imbalance.
% Voltage Imbalance
= 100 x

max voltage deviation from average voltage


average voltage

Example: Supply voltage is 460-3-60.


AB = 452 v
BC = 464 v
AC = 455 v
Average Voltage =
=

452 + 464 + 455


3
1371
3

= 457

72

3. For units with power exhaust: If a single power source is to be used, size wire to include power
exhaust MCA and MOCP. Check MCA and MOCP when power exhaust is powered through the
unit (must be in accordance with NEC and/or local codes). Determine the new MCA including the
power exhaust using the following formula:
MCA New = MCA unit only + MCA of Power Exhaust
For example, using a 50TFF006---5 unit with MCA = 28.9 and MOCP = 35, with
CRPWREXH030A01 power exhaust.
MCA New = 28.9 amps + 1.6 amps = 30.5 amps
If the new MCA does not exceed the published MOCP, then MOCP would not change. The MOCP
in this example is 35 amps, the MCA New is below 35, therefore the MOCP is acceptable. If MCA
New is larger than the published MOCP, raise the MOCP to the next larger size. For separate
power, the MOCP for the power exhaust will be 15 amps per NEC.
POWER EXHAUST
PART NO.

MCA
(230 v)

MCA
(460 v)

MCA
(575 v)

CRPWREXH021A01
CRPWREXH022A01
CRPWREXH023A01
CRPWREXH028A01
CRPWREXH029A01
CRPWREXH030A01

N/A
3.4
N/A
1.7
N/A
1.6

0.68
N/A
1.4
N/A
0.7
N/A

N/A
1.32
N/A
0.68
N/A
0.64

MOCP
(for separate
power source)
15
15
15
15
15
15

ELECTRICAL DATA UNITS WITHOUT CONVENIENCE OUTLET (cont)


UNIT
50TFF

NOMINAL
V-Ph-Hz

IFM
TYPE

VOLTAGE
RANGE

COMPRESSOR
(ea)

Min

RLA

Max

LRA

OFM
(ea)
Qty Hp FLA

Std
and
Alt

008

5.8
187

254

14.0

91.0

1/4

1.4

High

10.6

Std
and
Alt

2.8

460-3-60

414

508

6.4

42.0

1/4

0.7

High

575-3-60

Std
and
Alt

2.6
518

632

5.2

39.0

1/
4

0.7

High

4.8

Std

5.8

208/230-3-60

009

4.8

187

254

16.0

137.0

1/4

1.4

High

10.6

Std

2.6

460-3-60

414

508

8.3

69.0

1/4

0.7

High

4.8

Std
575-3-60

012

208/230-3-60

2.6
518

632

6.4

58.0

1/4

0.7

High

4.8

Std

5.8

Alt

187

High

254

15.8

130.0

1/
4

1.4

7.5

15.0

ELECTRIC
HEAT
Nominal
FLA
kW
/
/
7.8/10.4
21.7/ 25.0
12.0/16.0
33.4/ 38.5
18.6/24.8
51.7/ 59.7
24.0/32.0
66.7/ 77.0
31.9/42.4
88.4/102.0
/
/
7.8/10.4
21.7/ 25.0
12.0/16.0
33.4/ 38.5
18.6/24.8
51.7/ 59.7
24.0/32.0
66.7/ 77.0
31.9/42.4
88.4/102.0

13.9
16.7
16.5
19.8
27.8
33.4
33.0
39.7
41.7
50.2

13.9
16.7
16.5
19.8
27.8
33.4
33.0
39.7
41.7
50.2

17.0
17.1
34.0
34.1

17.0
17.1
34.0
34.1
/
/
7.8/10.4
21.7/ 25.0
12.0/16.0
33.4/ 38.5
18.6/24.8
51.7/ 59.7
24.0/32.0
66.7/ 77.0
31.9/42.4
88.4/102.0
/
/
7.8/10.4
21.7/ 25.0
12.0/16.0
33.4/ 38.5
18.6/24.8
51.7/ 59.7
24.0/32.0
66.7/ 77.0
31.9/42.4
88.4/102.0

13.9
16.7
16.5
19.8
27.8
33.4
33.0
39.7
41.7
50.2

13.9
16.7
16.5
19.8
27.8
33.4
33.0
39.7
41.7
50.2

17.0
17.1
34.0
34.1

17.0
17.1
34.0
34.1
/
/
7.8/10.4
21.7/ 25.0
12.0/16.0
33.4/ 38.5
24.0/32.0
66.7/ 77.0
31.9/42.4
88.4/102.0
37.5/50.0 104.2/120.3
/
/
7.8/10.4
21.7/ 25.0
12.0/16.0
33.4/ 38.5
24.0/32.0
66.7/ 77.0
31.9/42.4
88.4/102.0
37.5/50.0 104.2/120.3
/
/
7.8/10.4
21.7/ 25.0
12.0/16.0
33.4/ 38.5
24.0/32.0
66.7/ 77.0
31.9/42.4
88.4/102.0
37.5/50.0 104.2/120.3

POWER
SUPPLY

DISCONNECT
SIZE*

MCA

MOCP

FLA

40.1/ 40.1
40.1/ 40.1
48.9/ 55.4
71.9/ 81.8
90.6/103.5
117.7/134.8
44.9/ 44.9
44.9/ 44.9
54.9/ 61.4
77.9/ 87.8
96.6/109.5
123.7/140.8
18.4
26.9
28.1
45.0
52.9
65.9
20.6
26.9
30.8
47.8
55.6
68.7
14.9
23.9
45.3
16.7
26.1
47.5
44.6/ 44.6
44.6/ 44.6
48.9/ 55.4
71.9/ 81.8
90.6/103.5
117.7/134.8
49.4/ 49.4
49.4/ 49.4
54.9/ 61.4
77.9/ 87.8
96.6/109.5
123.7/140.8
22.7
24.1
28.1
45.0
52.9
65.9
24.9
26.9
30.8
47.8
55.6
68.7
17.6
23.9
45.3
19.4
26.1
47.5
44.2/ 44.2
44.2/ 44.2
48.9/ 55.4
90.6/103.5
117.7/134.8
137.5/157.6
45.9/ 45.9
45.9/ 45.9
51.1/ 57.5
92.8/105.6
119.9/136.9
139.7/159.7
53.4/ 53.4
53.4/ 53.4
60.4/ 66.9
102.1/115.0
129.2/146.3
149.0/169.0

45/ 45
45/ 45
50/ 60
80/ 90**
100/110**
125/150**
50/ 50
50/ 50
60/ 70**
80/ 90**
100/110**
125/150**
20
30
30
50
60
70**
25
30
35
50
60
70**
20
25
50
20
30
50
50/ 50
50/ 50
50/ 60
80/ 90**
100/110**
125/150**
60/ 60
60/ 60
60/ 70**
80/ 90**
100/110**
125/150**
25
25
30
50
60
70**
30
30
35
50
60
70**
20
25
50
25
30
50
50/ 50
50/ 50
60/ 60
100/110**
125/150**
150/175**
50/ 50
50/ 50
60/ 60
100/110**
125/150**
150/175**
50/ 50
60/ 60
60/ 80**
110/125**
150/150**
150/175**

42/ 42
42/ 42
45/ 51
66/ 75
83/ 95
108/124
48/ 48
48/ 48
51/ 56
72/ 81
89/101
114/129
19
25
26
41
49
61
22
25
28
44
51
63
16
22
42
18
24
44
47/ 47
47/ 47
47/ 51
66/ 75
83/ 95
108/124
52/ 52
52/ 52
52/ 56
72/ 81
89/101
114/129
24
24
26
41
49
61
26
26
28
44
51
63
18
22
42
20
24
44
46/ 46
45/ 45
45/ 51
83/ 95
108/124
127/147
48/ 48
47/ 47
47/ 53
85/ 97
110/126
128/147
57/ 57
56/ 56
56/ 62
94/106
119/135
137/156

LRA

229/229

273/273

138

130

97

114

321/321

365/365

161

184

135

152

307/307

326/326

374/374

See Legend and Notes on page 74.

73

50TFF

208/230-3-60

IFM
FLA

Electrical data 50TFF (cont)


ELECTRICAL DATA UNITS WITHOUT CONVENIENCE OUTLET (cont)
UNIT
50TFF

NOMINAL
V-Ph-Hz

IFM
TYPE

VOLTAGE
RANGE
Min

Max

COMPRESSOR
(ea)
RLA

LRA

OFM
(ea)
Qty

Hp

FLA

Std

50TFF

460-3-60

012

575-3-60

Alt

2.6

414

508

7.9

64.0

1/ 4

0.7

3.4

High

7.4

Std

2.6

Alt

518

632

6.6

52.0

1/ 4

0.7

3.4

High

7.4

Std

10.6

208/230-3-60

187

254

23.0

146.0

1/

1.4

Alt

15.0

Std

4.8

014
460-3-60

414

508

10.4

73.0

1/ 4

0.7

Alt

7.4

Std
575-3-60

4.8
518

632

8.3

58.4

1/ 4

0.7

Alt
LEGEND
FLA
Full Load Amps
HACR Heating, Air Conditioning and Refrigeration
IFM
Indoor (Evaporator) Fan Motor
LRA
Locked Rotor Amps
MCA
Minimum Circuit Amps
MOCP Maximum Overcurrent Protection
NEC
National Electrical Code
OFM
Outdoor (Condenser) Fan Motor
RLA
Rated Load Amps
*Used to determine minimum disconnect per NEC.
Fuse or HACR circuit breaker per NEC.
**Fuse only.
Compressor no. 1 is shown in table.
208/230-3-60: Compressor no. 2 RLA is 14.1 amps and LRA is 105 amps.
460-3-60: Compressor no. 2 RLA is 7.1 amps and LRA is 55 amps.
575-3-60: Compressor no. 2 RLA is 6.4 amps and LRA is 40 amps.
NOTES:
1. In compliance with NEC requirements for multimotor and combination load equipment (refer to NEC
Articles 430 and 440), the overcurrent protective device for the unit shall be fuse or HACR breaker.
Canadian units may be fuse or circuit breaker.
2. Unbalanced 3-Phase Supply Voltage
Never operate a motor where a phase imbalance in supply voltage is greater than 2%. Use the following formula to determine the percent of voltage imbalance.
% Voltage Imbalance
max voltage deviation from average voltage
= 100 x
average voltage
Example: Supply voltage is 460-3-60.
AB = 452 v
BC = 464 v
AC = 455 v
452 + 464 + 455
Average Voltage =
3
1371
=
3
= 457
Determine maximum deviation from average voltage.
(AB) 457 452 = 5 v
(BC) 464 457 = 7 v
(AC) 457 455 = 2 v
Maximum deviation is 7 v.
Determine percent of voltage imbalance.
7
% Voltage Imbalance = 100 x
457
= 1.53%

74

IFM
FLA

7.4

ELECTRIC
HEAT
Nominal
FLA
kW

16.5
19.8
27.8
33.4
33.0
39.7
41.7
50.2
50.0
60.1

16.5
19.8
27.8
33.4
33.0
39.7
41.7
50.2
50.0
60.1

16.5
19.8
27.8
33.4
33.0
39.7
41.7
50.2
50.0
60.1

17.0
17.1
34.0
34.1
51.0
51.2

17.0
17.1
34.0
34.1
51.0
51.2

17.0
18.0
34.0
36.0
51.0
51.2
/
/
7.8/10.4
21.7/ 25.0
12.0/16.0
33.4/ 38.5
24.0/32.0
66.7/ 77.0
31.9/42.4
88.4/102.0
37.5/50.0
104.2/120.3
/
/
7.8/10.4
21.7/ 25.0
12.0/16.0
33.4/ 38.5
24.0/32.0
66.7/ 77.0
31.9/42.4
88.4/102.0
37.5/50.0
104.2/120.3

16.5
19.8
27.8
33.4
33.0
39.7
41.7
50.2
50.0
60.1

16.5
19.8
27.8
33.4
33.0
39.7
41.7
50.2
50.0
60.1

17.0
17.1
34.0
34.1
51.0
51.2

17.0
17.1
34.0
34.1
51.0
51.2

POWER
SUPPLY

DISCONNECT
SIZE*

MCA

MOCP

FLA

21.8
28.1
45.0
52.9
65.9
63.4
22.6
29.1
46.0
53.9
66.9
64.4
26.6
34.1
51.0
58.9
71.9
69.4
18.9
23.9
45.3
55.8
19.7
24.7
46.1
54.6
23.7
28.7
50.1
58.6
65.2/ 65.2
65.2/ 65.2
65.2/ 65.2
96.6/109.5
123.7/140.8
143.5/163.6
69.6/ 69.6
69.6/ 69.6
69.6/ 69.6
102.1/115.0
129.2/146.3
149.0/169.0
29.6
30.8
47.8
55.6
68.7
66.1
32.2
34.1
51.0
58.9
71.9
69.4
23.6
26.1
47.5
56.0
25.7
28.7
50.1
58.6

25
30
50
60
70**
70**
25
30
50
60
70**
70**
30
35
60
60
80**
80**
25
25
50
60
25
25
50
60
30
35
60
70**
80/ 80**
80/ 80**
70/ 70**
100/110**
125/150**
150/175**
80/ 80**
80/ 80**
80/ 80**
110/125**
150/150**
150/175**
40
40
50
60
70**
80**
45
45
60
60
80**
80**
30
30
50
60
30
35
60
70**

23
26
41
49
61
72
24
27
42
50
62
73
28
31
47
54
66
78
20
22
42
61
21
23
42
62
25
26
46
66
68/ 68
68/ 68
68/ 68
89/101
114/129
132/151
73/ 73
73/ 73
73/ 73
94/106
119/135
137/156
31
31
44
51
63
75
34
34
47
54
66
78
25
25
44
53
27
27
46
66

LRA

152

191

185

126

152

160

383/383

406/406

192

203

153

162

This amount of phase imbalance is satisfactory as it is below the maximum allowable 2%.
IMPORTANT: If the supply voltage phase imbalance is more than 2%, contact your local electric utility company immediately.
3. For units with power exhaust: If a single power source is to be used, size wire to include power
exhaust MCA and MOCP. Check MCA and MOCP when power exhaust is powered through the
unit (must be in accordance with NEC and/or local codes). Determine the new MCA including the
power exhaust using the following formula:
MCA New = MCA unit only + MCA of Power Exhaust
For example, using a 50TFF008 unit with MCA = 40.1 and MOCP = 45, with CRPWREXH030A01
power exhaust.
MCA New = 40.1 amps + 1.6 amps = 41.7 amps
If the new MCA does not exceed the published MOCP, then MOCP would not change. The MOCP
in this example is 45 amps, the MCA New is below 45, therefore the MOCP is acceptable. If MCA
New is larger than the published MOCP, raise the MOCP to the next larger size. For separate
power, the MOCP for the power exhaust will be 15 amps per NEC.
POWER EXHAUST
PART NO.

MCA
(230 v)

MCA
(460 v)

MCA
(575 v)

CRPWREXH021A01
CRPWREXH022A01
CRPWREXH023A01
CRPWREXH028A01
CRPWREXH029A01
CRPWREXH030A01

N/A
3.4
N/A
1.7
N/A
1.6

0.68
N/A
1.4
N/A
0.7
N/A

N/A
1.32
N/A
0.68
N/A
0.64

MOCP
(for separate
power source)
15
15
15
15
15
15

4. Determine heater capacity using multiplication factors table below:


HEATER RATING
VOLTAGE
200
240
480
600

ACTUAL HEATER VOLTAGE


208

230

240

380

440

460

480

550

575

600

0.694 0.751 0.918 1.000

0.626 0.840 0.918 1.000

0.840 0.918 1.000

NOTE: The following equation converts kW of heat energy to Btuh: kW x 3.412 = Btuh.
EXAMPLE: 32.0 kW (at 240 v) heater on 208 v
= 32.0 (.751 mult factor)
= 24.0 kW capacity at 208 v
5. For 50TFF electrical data with convenience outlet, see unit nameplate or contact service
engineering.

ELECTRICAL DATA UNITS WITH CONVENIENCE OUTLET


UNIT
50TFF

NOMINAL
V-PH-Hz

IFM
TYPE

VOLTAGE
RANGE
Min

Max

COMPRESSOR
(ea)
Qty

RLA

LRA

OFM (ea)
Qty

Hp

FLA

STD
208/230-1-60

3.5
187

254

16.2

96

1/

1.4

ALT

4.9

STD

3.5

ALT

HEATER
MODEL NO.
CRHEATER---A00

187

254

10.2

75

1/ 4

1.4

4.9

004

460-3-60

HIGH

5.2

STD

1.3

ALT

414

508

4.4

40

1/ 4

0.8

HIGH

575-3-60

STD
ALT
HIGH

2.1

2.6

518

632

3.7

31

1/ 4

0.8

1.3
2.1
2.6

LEGEND
FLA
HACR
IFM
LRA
MCA
MOCP
NEC
OFM
RLA

Full Load Amps


Heating, Air Conditioning and Refrigeration
Indoor (Evaporator) Fan Motor
Locked Rotor Amps
Minimum Circuit Amps
Maximum Overcurrent Protection
National Electrical Code
Outdoor (Condenser) Fan Motor
Rated Load Amps

*Used to determine minimum disconnect per NEC.


Fuse or HACR circuit breaker.

NONE
001
002
003
004
002 and 002
NONE
001
002
003
004
002 and 002
NONE
001
002
003
004
005
NONE
001
002
003
004
005
NONE
001
002
003
004
005
NONE
006
007
008
009
NONE
006
007
008
009
NONE
006
007
008
009
NONE
NONE
NONE

ELECTRIC HEAT
Nominal
kW
/
3.3/ 4.4
4.9/ 6.5
6.4/ 8.7
7.9/10.5
9.8/13.0
/
3.3/ 4.4
4.9/ 6.5
6.5/ 8.7
7.9/10.5
9.8/13.0
/
3.3/ 4.4
4.9/ 6.5
6.5/ 8.7
7.9/10.5
12.2/16.0
/
3.3/ 4.4
4.9/ 6.5
6.5/ 8.7
7.9/10.5
12.3/16.0
/
3.3/ 4.4
4.9/ 6.5
6.5/ 8.7
7.9/10.5
12.3/16.0

6.0
8.8
11.5
14.0

6.0
8.8
11.5
14.0

6.0
8.8
11.5
14.0

DISCONNECT
SIZE

POWER SUPPLY

FLA

MCA

MOCP*

FLA

LRA

SINGLE POINT
BOX P/N
CRSINGLE---A00

/
15.9/18.3
23.5/27.1
31.4/36.3
37.9/43.8
46.9/54.2
/
15.9/18.3
23.5/27.1
31.4/36.3
37.9/43.8
46.9/54.2
/
9.2/10.6
13.6/15.6
18.1/20.9
21.9/25.3
33.4/38.4
/
9.2/10.6
13.6/15.6
18.1/20.9
21.9/25.3
33.4/38.4
/
9.2/10.6
13.6/15.6
18.1/20.9
21.9/25.3
33.4/38.4

7.2
10.6
13.8
16.8

7.2
10.6
13.8
16.8

7.2
10.6
13.8
16.8

31.2/31.2
31.2/32.3
38.7/43.2
48.6/54.7
56.8/64.1
68.0/77.1
32.6/32.6
32.6/34.0
40.5/45.0
50.4/56.4
58.5/65.8
69.8/78.8
22.5/22.5
22.5/23.0
27.3/29.4
33.1/36.0
37.7/42.0
52.1/57.9
23.9/23.9
23.9/24.8
29.1/31.1
34.8/37.7
39.5/43.7
53.8/59.6
24.2/24.2
24.2/25.2
29.5/31.5
35.2/38.1
39.9/44.1
54.2/60.0
9.8
13.4
17.6
21.6
25.4
10.6
14.4
18.6
22.6
26.4
11.1
15.0
19.2
23.3
27.0
7.2
7.7
8.0

35/35
35/35
40/45
50/60
60/70
70/80
40/40
40/40
45/45
60/60
60/70
70/80
30/30
30/30
30/30
35/40
40/45
60/60
30/30
30/30
30/35
35/40
40/45
60/60
30/30
30/30
35/35
40/40
40/45
60/60
15
15
20
25
30
15
15
20
25
30
15
20
20
25
30
15
15
15

30/30
30/31
37/41
46/51
53/60
64/72
31/31
31/32
38/42
47/53
55/61
65/73
23/23
23/23
25/28
30/34
35/39
48/54
25/25
25/25
27/29
32/35
36/40
50/55
25/25
25/25
27/29
32/36
37/41
50/56
10
12
16
20
23
11
13
17
21
24
11
14
18
21
25
8
9
9

111/111
111/111
111/111
111/111
111/111
111/111
116/116
116/116
116/116
116/116
116/116
116/116
90/ 90
90 90
90/ 90
90/ 90
90/ 90
90/ 90
95/ 95
95/ 95
95/ 95
95/ 95
95/ 95
95/ 95
114/114
114/114
114/114
114/114
114/114
114/114
47
47
47
47
47
50
50
50
50
50
59
59
59
59
59
36
39
58

004
004

004
004

50TFF

208/230-3-60

IFM
FLA

Determine maximum deviation from average voltage.


(AB) 457 452 = 5 v
(BC) 464 457 = 7 v
(AC) 457 455 = 2 v
Maximum deviation is 7 v.
Determine percent of voltage imbalance.
% Voltage Imbalance = 100 x

7
457

= 1.53%
This amount of phase imbalance is satisfactory as it is below the maximum allowable 2%.
IMPORTANT: If the supply voltage phase imbalance is more than 2%, contact your local electric utility company immediately.

NOTES:
1. In compliance with NEC requirements for multimotor and combination load equipment (refer to NEC
Articles 430 and 440), the overcurrent protective device for the unit shall be fuse or HACR breaker.
Canadian units may be fuse or circuit breaker.
2. Unbalanced 3-Phase Supply Voltage
Never operate a motor where a phase imbalance in supply voltage is greater than 2%. Use the following formula to determine the percent of voltage imbalance.
% Voltage Imbalance
= 100 x

max voltage deviation from average voltage


average voltage

Example: Supply voltage is 460-3-60.


AB = 452 v
BC = 464 v
AC = 455 v
Average Voltage =
=

452 + 464 + 455


3
1371
3

= 457

3. For units with power exhaust: If a single power source is to be used, size wire to include power
exhaust MCA and MOCP. Check MCA and MOCP when power exhaust is powered through the
unit (must be in accordance with NEC and/or local codes). Determine the new MCA including the
power exhaust using the following formula:
MCA New = MCA unit only + MCA of Power Exhaust
For example, using a 50TFF006---5 unit with MCA = 28.9 and MOCP = 35, with
CRPWREXH030A01 power exhaust.
MCA New = 28.9 amps + 1.6 amps = 30.5 amps
If the new MCA does not exceed the published MOCP, then MOCP would not change. The MOCP
in this example is 35 amps, the MCA New is below 35, therefore the MOCP is acceptable. If MCA
New is larger than the published MOCP, raise the MOCP to the next larger size. For separate
power, the MOCP for the power exhaust will be 15 amps per NEC.
POWER EXHAUST
PART NO.

MCA
(230 v)

MCA
(460 v)

MCA
(575 v)

CRPWREXH021A01
CRPWREXH022A01
CRPWREXH023A01
CRPWREXH028A01
CRPWREXH029A01
CRPWREXH030A01

N/A
3.4
N/A
1.7
N/A
1.6

0.68
N/A
1.4
N/A
0.7
N/A

N/A
1.32
N/A
0.68
N/A
0.64

MOCP
(for separate
power source)
15
15
15
15
15
15

75

Electrical data 50TFF (cont)


ELECTRICAL DATA UNITS WITH CONVENIENCE OUTLET (cont)
UNIT
50TFF

NOMINAL
V-PH-Hz

IFM
TYPE

VOLTAGE
RANGE
Min

Max

COMPRESSOR
(ea)
Qty

RLA

LRA

OFM (ea)
Qty

Hp

FLA

STD

50TFF

208/230-1-60

208/230-3-60

IFM
FLA

3.5
187

254

23.3

118

1/

1.4

ALT

4.9

STD

3.5

ALT

187

254

15.4

90

1/ 4

1.4

4.9

005

460-3-60

HIGH

5.2

STD

1.8

ALT

414

508

8.3

45

1/ 4

0.8

HIGH

575-3-60

STD
ALT
HIGH

2.1

2.6

518

632

6.4

36

1/ 4

0.8

1.8
2.1
2.6

HEATER
MODEL NO.
CRHEATER---A00
NONE
001
003
002 and 002
003 and 003
004 and 004
NONE
001
003
002 and 002
003 and 003
004 and 004
NONE
002
003
005
004 and 004
NONE
002
003
005
004 and 004
NONE
002
003
005
004 and 004
NONE
006
008
009
008 and 008
NONE
006
008
009
008 and 008
NONE
006
008
009
008 and 008
NONE
NONE
NONE

LEGEND
FLA
HACR
IFM
LRA
MCA
MOCP
NEC
OFM
RLA

Full Load Amps


Heating, Air Conditioning and Refrigeration
Indoor (Evaporator) Fan Motor
Locked Rotor Amps
Minimum Circuit Amps
Maximum Overcurrent Protection
National Electrical Code
Outdoor (Condenser) Fan Motor
Rated Load Amps

*Used to determine minimum disconnect per NEC.


Fuse or HACR circuit breaker.

ELECTRIC HEAT
Nominal
kW
/
3.3/ 4.4
6.5/ 8.7
9.3/13.0
13.1/17.4
15.8/21.0
/
3.3/ 4.4
6.5/ 8.7
9.3/13.0
13.1/17.4
15.8/21.0
/
4.9/ 6.5
6.5/ 8.7
12.0/16.0
15.8/21.0
/
4.9/ 6.5
6.5/ 8.7
12.0/16.0
15.8/21.0
/
4.9/ 6.5
6.5/ 8.7
12.0/16.0
15.8/21.0

6.0
11.5
14.0
23.0

6.0
11.5
14.0
23.0

6.0
11.5
14.0
23.0

DISCONNECT
SIZE

POWER SUPPLY

FLA

MCA

MOCP*

FLA

LRA

/
15.9/18.3
31.4/36.3
46.9/54.2
62.8/72.5
75.8/87.5
/
15.9/18.3
31.4/36.3
46.9/54.2
62.8/72.5
75.8/87.5
/
13.6/15.6
18.1/20.9
33.4/38.4
43.8/50.5
/
13.6/15.6
18.1/20.9
33.4/38.4
43.8/50.5
/
13.6/15.6
18.1/20.9
33.4/38.4
43.8/50.5

7.2
13.8
16.8
27.7

7.2
13.8
16.8
27.7

7.2
13.8
16.8
27.7

40.0/ 40.0
40.0/ 40.0
48.6/ 54.7
68.0/ 77.1
87.9/100.0
104.2/118.8
41.4/ 41.4
41.4/ 41.4
50.4/ 56.4
69.8/ 78.8
89.7/101.8
105.9/120.5
29.0/ 29.0
29.0/ 29.4
33.1/ 36.0
52.1/ 57.9
65.1/ 73.5
30.4/ 30.4
30.4/ 31.1
34.8/ 37.7
53.8/ 59.6
66.9/ 75.3
30.7/ 30.7
30.7/ 31.5
35.2/ 38.1
54.2/ 60.0
67.2/ 75.7
15.2
15.2
22.3
26.0
39.6
15.5
15.5
22.6
26.4
39.9
16.0
16.0
23.3
27.0
40.6
10.9
11.1
11.4

45/ 45
45/ 45
50/ 60
70/ 80
90/100
110/125
50/ 50
50/ 50
60/ 60
70/ 80
90/110
110/125
35/ 35
35 35
35/ 40
60/ 60
70/ 80
35/ 35
35/ 35
35/ 40
60/ 60
70/ 80
35/ 35
35/ 35
40/ 40
60/ 60
70/ 80
20
20
25
30
40
20
20
25
30
40
20
20
25
30
45
15
15
15

38/ 38
38/ 38
46/ 51
64/ 72
82/ 93
97/110
40/ 40
40/ 40
47/ 53
65/ 73
83/ 95
98/112
29/ 29
29/ 29
30/ 34
48/ 54
60/ 68
30/ 30
30/ 30
32/ 35
50/ 55
62/ 69
31/ 31
31/ 31
32 /36
50/ 56
62/ 70
15
15
20
24
36
15
15
21
24
37
16
16
21
25
37
12
12
12

134/134
134/134
134/134
134/134
134/134
134/134
138/138
138/138
138/138
138/138
138/138
138/138
106/106
106/106
106/106
106/106
106/106
110/110
110/110
110/110
110/110
110/110
129/129
129/129
129/129
129/129
129/129
53
53
53
53
53
55
55
55
55
55
64
64
64
64
64
42
44
51

SINGLE POINT
BOX P/N
CRSINGLE---A00

004
004
004

004
004
004

002

002

002

Determine maximum deviation from average voltage.


(AB) 457 452 = 5 v
(BC) 464 457 = 7 v
(AC) 457 455 = 2 v
Maximum deviation is 7 v.
Determine percent of voltage imbalance.
% Voltage Imbalance = 100 x

7
457

= 1.53%
This amount of phase imbalance is satisfactory as it is below the maximum allowable 2%.
IMPORTANT: If the supply voltage phase imbalance is more than 2%, contact your local electric utility company immediately.

NOTES:
1. In compliance with NEC requirements for multimotor and combination load equipment (refer to NEC
Articles 430 and 440), the overcurrent protective device for the unit shall be fuse or HACR breaker.
Canadian units may be fuse or circuit breaker.
2. Unbalanced 3-Phase Supply Voltage
Never operate a motor where a phase imbalance in supply voltage is greater than 2%. Use the following formula to determine the percent of voltage imbalance.
% Voltage Imbalance
= 100 x

max voltage deviation from average voltage


average voltage

Example: Supply voltage is 460-3-60.


AB = 452 v
BC = 464 v
AC = 455 v
Average Voltage =
=

452 + 464 + 455


3
1371
3

= 457

76

3. For units with power exhaust: If a single power source is to be used, size wire to include power
exhaust MCA and MOCP. Check MCA and MOCP when power exhaust is powered through the
unit (must be in accordance with NEC and/or local codes). Determine the new MCA including the
power exhaust using the following formula:
MCA New = MCA unit only + MCA of Power Exhaust
For example, using a 50TFF006---5 unit with MCA = 28.9 and MOCP = 35, with
CRPWREXH030A01 power exhaust.
MCA New = 28.9 amps + 1.6 amps = 30.5 amps
If the new MCA does not exceed the published MOCP, then MOCP would not change. The MOCP
in this example is 35 amps, the MCA New is below 35, therefore the MOCP is acceptable. If MCA
New is larger than the published MOCP, raise the MOCP to the next larger size. For separate
power, the MOCP for the power exhaust will be 15 amps per NEC.
POWER EXHAUST
PART NO.

MCA
(230 v)

MCA
(460 v)

MCA
(575 v)

CRPWREXH021A01
CRPWREXH022A01
CRPWREXH023A01
CRPWREXH028A01
CRPWREXH029A01
CRPWREXH030A01

N/A
3.4
N/A
1.7
N/A
1.6

0.68
N/A
1.4
N/A
0.7
N/A

N/A
1.32
N/A
0.68
N/A
0.64

MOCP
(for separate
power source)
15
15
15
15
15
15

ELECTRICAL DATA UNITS WITH CONVENIENCE OUTLET (cont)


UNIT
50TFF

NOMINAL
V-PH-Hz

IFM
TYPE

VOLTAGE
RANGE
Min

Max

COMPRESSOR
(ea)
Qty

RLA

LRA

OFM (ea)
Qty

Hp

FLA

STD
208/230-1-60

5.9
187

254

28.8

147

1/
4

1.4

ALT

6.6

STD

5.9

ALT

HEATER
MODEL NO.
CRHEATER---A00

187

254

16

114

1/4

1.4

5.2

006

460-3-60

HIGH

7.5

STD

3.1

ALT

414

508

7.4

64

1/
4

0.8

HIGH

575-3-60

STD
ALT
HIGH

2.6

3.4

518

632

6.2

52

1/4

0.8

3.1
2.6
3.4

LEGEND
FLA
HACR
IFM
LRA
MCA
MOCP
NEC
OFM
RLA

Full Load Amps


Heating, Air Conditioning and Refrigeration
Indoor (Evaporator) Fan Motor
Locked Rotor Amps
Minimum Circuit Amps
Maximum Overcurrent Protection
National Electrical Code
Outdoor (Condenser) Fan Motor
Rated Load Amps

*Used to determine minimum disconnect per NEC.


Fuse or HACR circuit breaker.

NONE
002
003
002 and 002
003 and 003
004 and 004
NONE
002
003
002 and 002
003 and 003
004 and 004
NONE
002
004
005
004 and 004
004 and 005
NONE
002
004
005
004 and 004
004 and 005
NONE
002
004
005
004 and 004
004 and 005
NONE
006
008
009
008 and 008
008 and 009
NONE
006
008
009
008 and 008
008 and 009
NONE
006
008
009
008 and 008
008 and 009
NONE
NONE
NONE

ELECTRIC HEAT
Nominal
kW
/
4.9/ 6.5
6.5/ 8.7
9.8/13.0
13.1/17.4
15.8/21.0
/
4.9/ 6.5
6.5/ 8.7
9.8/13.0
13.1/17.4
15.8/21.0
/
4.9/ 6.5
7.9/10.5
12.0/16.0
15.8/21.0
19.9/26.5
/
4.9/ 6.5
7.9/10.5
12.0/16.0
15.8/21.0
19.9/26.5
/
4.9/ 6.5
7.9/10.5
12.0/16.0
15.8/21.0
19.9/26.5

6.0
11.5
14.0
23.0
25.0

6.0
11.5
14.0
23.0
25.0

6.0
11.5
14.0
23.0
25.0

DISCONNECT
SIZE

POWER SUPPLY

FLA

MCA

MOCP*

FLA

LRA

SINGLE POINT
BOX P/N
CRSINGLE---A00

/
23.5/27.1
31.4/36.3
46.9/54.2
62.8/72.5
75.8/87.5
/
23.5/27.1
31.4/36.3
46.9/54.2
62.8/72.5
75.8/87.5
/
13.6/15.6
21.9/25.3
33.4/38.4
43.8/50.5
55.2/63.8
/
13.6/15.6
21.9/25.3
33.4/38.4
43.8/50.5
55.2/63.8
/
13.6/15.6
21.9/25.3
33.4/38.4
43.8/50.5
55.2/63.8

7.2
13.8
16.8
27.7
30.1

7.2
13.8
16.8
27.7
30.1

7.2
13.8
16.8
27.7
30.1

49.3/ 49.3
49.3/ 49.3
51.6/ 57.7
71.0/ 80.1
90.9/103.0
107.2/121.8
50.0/ 50.0
50.0/ 50.0
52.5/ 58.6
71.9/ 81.0
91.8/103.9
108.0/122.6
32.1/ 32.1
32.1/ 32.4
40.7/ 44.4
55.1/ 60.9
68.1/ 76.5
82.4/ 92.5
31.4/ 31.4
31.4/ 31.5
39.9/ 43.5
54.2/ 60.0
67.2/ 75.7
81.6/ 91.6
33.7/ 33.7
33.7/ 34.4
42.7/ 46.4
57.1/ 62.9
70.1/ 78.5
84.4/ 94.5
15.3
15.6
23.9
27.6
41.2
44.2
15.6
16.0
24.3
28.0
41.6
44.6
15.6
16.0
24.3
28.0
41.6
44.6
11.5
11.7
11.7

60/ 60
60/ 60
60/ 60
80/ 90
100/110
110/125
60/ 60
60/ 60
60/ 60
80/ 90
100/110
110/125
40/ 40
40/ 40
45/ 45
60/ 70
70/ 80
90/100
40/ 40
40/ 40
40/ 45
60/ 60
70/ 80
90/100
40/ 40
40/ 40
45/ 50
60/ 70
80/ 80
90/100
20
20
25
30
45
45
20
20
25
30
45
45
20
20
25
30
45
45
15
15
15

47/ 47
47/ 47
48/ 54
66/ 75
85/ 96
100/113
48/ 48
48/ 48
49/ 55
67/ 75
85/ 96
100/114
32/ 32
32/ 32
37/ 41
51/ 57
63/ 70
76/ 86
32/ 32
32/ 32
37/ 41
50/ 56
62/ 70
75/ 85
34/ 34
34/ 34
39/4 3
53/ 58
65/ 72
78/ 87
15
15
22
25
38
41
16
16
22
26
38
41
16
16
22
26
38
41
13
13
13

166/166
166/166
166/166
166/166
166/166
166/166
188/188
188/188
188/188
188/188
188/188
188/188
133/133
133/133
133/133
133/133
133/133
133/133
153/153
153/153
153/153
153/153
153/153
153/153
179/179
179/179
179/179
179/179
179/179
179/179
74
74
74
74
74
74
83
83
83
83
83
83
96
96
96
96
96
96
60
67
77

004
004
004

004
004
004

002
002
002

002
002

002
002
002

50TFF

208/230-3-60

IFM
FLA

Determine maximum deviation from average voltage.


(AB) 457 452 = 5 v
(BC) 464 457 = 7 v
(AC) 457 455 = 2 v
Maximum deviation is 7 v.
Determine percent of voltage imbalance.
% Voltage Imbalance = 100 x

7
457

= 1.53%
This amount of phase imbalance is satisfactory as it is below the maximum allowable 2%.
IMPORTANT: If the supply voltage phase imbalance is more than 2%, contact your local electric utility company immediately.

NOTES:
1. In compliance with NEC requirements for multimotor and combination load equipment (refer to NEC
Articles 430 and 440), the overcurrent protective device for the unit shall be fuse or HACR breaker.
Canadian units may be fuse or circuit breaker.
2. Unbalanced 3-Phase Supply Voltage
Never operate a motor where a phase imbalance in supply voltage is greater than 2%. Use the following formula to determine the percent of voltage imbalance.
% Voltage Imbalance
= 100 x

max voltage deviation from average voltage


average voltage

Example: Supply voltage is 460-3-60.


AB = 452 v
BC = 464 v
AC = 455 v
Average Voltage =
=

452 + 464 + 455


3
1371
3

= 457

3. For units with power exhaust: If a single power source is to be used, size wire to include power
exhaust MCA and MOCP. Check MCA and MOCP when power exhaust is powered through the
unit (must be in accordance with NEC and/or local codes). Determine the new MCA including the
power exhaust using the following formula:
MCA New = MCA unit only + MCA of Power Exhaust
For example, using a 50TFF006---5 unit with MCA = 28.9 and MOCP = 35, with
CRPWREXH030A01 power exhaust.
MCA New = 28.9 amps + 1.6 amps = 30.5 amps
If the new MCA does not exceed the published MOCP, then MOCP would not change. The MOCP
in this example is 35 amps, the MCA New is below 35, therefore the MOCP is acceptable. If MCA
New is larger than the published MOCP, raise the MOCP to the next larger size. For separate
power, the MOCP for the power exhaust will be 15 amps per NEC.
POWER EXHAUST
PART NO.

MCA
(230 v)

MCA
(460 v)

MCA
(575 v)

CRPWREXH021A01
CRPWREXH022A01
CRPWREXH023A01
CRPWREXH028A01
CRPWREXH029A01
CRPWREXH030A01

N/A
3.4
N/A
1.7
N/A
1.6

0.68
N/A
1.4
N/A
0.7
N/A

N/A
1.32
N/A
0.68
N/A
0.64

MOCP
(for separate
power source)
15
15
15
15
15
15

77

Electrical data 50TFF (cont)


ELECTRICAL DATA UNITS WITH CONVENIENCE OUTLET (cont)
UNIT
50TFF

NOMINAL
V-PH-Hz

IFM
TYPE

VOLTAGE
RANGE
Min

Max

COMPRESSOR
(ea)
Qty

RLA

LRA

OFM (ea)
Qty

Hp

FLA

STD

50TFF

208/230-3-60

IFM
FLA

HEATER
MODEL NO.
CRHEATER---A00

5.2
187

254

20.6

146

1/

1.4

HIGH

7.5

STD

2.6

007

460-3-60

414

508

9.5

73

1/ 4

0.9

HIGH

575-3-60

STD
HIGH

3.4

518

632

7.6

62

1/

0.9

2.6
3.4

LEGEND
FLA
HACR
IFM
LRA
MCA
MOCP
NEC
OFM
RLA

Full Load Amps


Heating, Air Conditioning and Refrigeration
Indoor (Evaporator) Fan Motor
Locked Rotor Amps
Minimum Circuit Amps
Maximum Overcurrent Protection
National Electrical Code
Outdoor (Condenser) Fan Motor
Rated Load Amps

*Used to determine minimum disconnect per NEC.


Fuse or HACR circuit breaker.

NONE
002
004
005
004 and 004
004 and 005
NONE
002
004
005
004 and 004
004 and 005
NONE
006
008
009
008 and 008
008 and 009
NONE
006
008
009
008 and 008
008 and 009
NONE
NONE

ELECTRIC HEAT
Nominal
kW
/
4.9/ 6.5
7.9/10.5
12.0/16.0
15.8/21.0
19.9/26.5
/
4.9/ 6.5
7.9/10.5
12.0/16.0
15.8/21.0
19.9/26.5

6.0
11.5
14.0
23.0
25.5

6.0
11.5
14.0
23.0
25.5

DISCONNECT
SIZE

POWER SUPPLY

FLA

MCA

MOCP*

FLA

LRA

SINGLE POINT
BOX P/N
CRSINGLE---A00

/
13.6/15.6
21.9/25.3
33.4/38.4
43.8/50.5
55.2/63.8
/
13.6/15.6
21.9/25.3
33.4/38.4
43.8/50.5
55.2/63.8

7.2
13.8
16.8
27.7
30.7

7.2
13.8
16.8
27.7
30.7

37.2/37.2
37.2/37.2
37.2/38.1
54.2/60.0
67.2/75.7
81.6/91.6
39.5/39.5
39.5/39.5
39.5/40.9
57.1/62.9
70.1/78.5
84.4/94.5
17.6
17.6
20.5
27.0
40.6
44.3
18.4
18.4
21.5
28.0
41.6
45.3
13.1
13.7

45/ 45
45/ 45
40/ 45
60/ 60
70/ 80
90/100
45/ 45
45/ 45
45/ 50
60/ 70
80/ 80
90/100
20
20
25
30
45
45
25
25
25
30
45
50
20
20

37/37
37/37
37/41
50/56
62/70
75/85
39/39
39/39
39/43
53/58
65/72
78/87
17
17
21
25
37
41
18
18
22
26
38
42
14
15

184/184
184/184
184/184
184/184
184/184
184/184
210/210
210/210
210/210
210/210
210/210
210/210
92
92
92
92
92
92
105
105
105
105
105
105
77
87

002
002

002
002
002

Determine maximum deviation from average voltage.


(AB) 457 452 = 5 v
(BC) 464 457 = 7 v
(AC) 457 455 = 2 v
Maximum deviation is 7 v.
Determine percent of voltage imbalance.
% Voltage Imbalance = 100 x

7
457

= 1.53%
This amount of phase imbalance is satisfactory as it is below the maximum allowable 2%.
IMPORTANT: If the supply voltage phase imbalance is more than 2%, contact your local electric utility company immediately.

NOTES:
1. In compliance with NEC requirements for multimotor and combination load equipment (refer to NEC
Articles 430 and 440), the overcurrent protective device for the unit shall be fuse or HACR breaker.
Canadian units may be fuse or circuit breaker.
2. Unbalanced 3-Phase Supply Voltage
Never operate a motor where a phase imbalance in supply voltage is greater than 2%. Use the following formula to determine the percent of voltage imbalance.
% Voltage Imbalance
= 100 x

max voltage deviation from average voltage


average voltage

Example: Supply voltage is 460-3-60.


AB = 452 v
BC = 464 v
AC = 455 v
Average Voltage =
=

452 + 464 + 455


3
1371
3

= 457

78

3. For units with power exhaust: If a single power source is to be used, size wire to include power
exhaust MCA and MOCP. Check MCA and MOCP when power exhaust is powered through the
unit (must be in accordance with NEC and/or local codes). Determine the new MCA including the
power exhaust using the following formula:
MCA New = MCA unit only + MCA of Power Exhaust
For example, using a 50TFF006---5 unit with MCA = 28.9 and MOCP = 35, with
CRPWREXH030A01 power exhaust.
MCA New = 28.9 amps + 1.6 amps = 30.5 amps
If the new MCA does not exceed the published MOCP, then MOCP would not change. The MOCP
in this example is 35 amps, the MCA New is below 35, therefore the MOCP is acceptable. If MCA
New is larger than the published MOCP, raise the MOCP to the next larger size. For separate
power, the MOCP for the power exhaust will be 15 amps per NEC.
POWER EXHAUST
PART NO.

MCA
(230 v)

MCA
(460 v)

MCA
(575 v)

CRPWREXH021A01
CRPWREXH022A01
CRPWREXH023A01
CRPWREXH028A01
CRPWREXH029A01
CRPWREXH030A01

N/A
3.4
N/A
1.7
N/A
1.6

0.68
N/A
1.4
N/A
0.7
N/A

N/A
1.32
N/A
0.68
N/A
0.64

MOCP
(for separate
power source)
15
15
15
15
15
15

ELECTRICAL DATA UNITS WITH CONVENIENCE OUTLET (cont)


UNIT
50TFF

NOMINAL
V-PH-Hz

IFM
TYPE

VOLTAGE
RANGE
Min

Max

COMPRESSOR
(ea)
Qty

RLA

LRA

OFM (ea)
Qty

Hp

FLA

STD

208/230-3-60

ALT

IFM
FLA

5.8

187

254

14

91

1/
4

1.4

5.8

10.6

STD

2.6

008

460-3-60

575-3-60

ALT

508

6.4

42

1/
4

0.7

2.6

HIGH

4.8

STD

2.6

ALT

518

632

5.2

39

1/
4

0.7

2.6

HIGH

4.8

STD

5.8

208/230-3-60

009

414

187

254

17.3

120

1/4

1.4

HIGH

10.6

STD

2.6

460-3-60

414

508

7.9

70

1/4

0.7

HIGH

4.8

STD

2.6
518

575-3-60

632

5.5

HIGH

50

1/4

0.7
4.8

NONE
017
010
011
012
012 and 017
NONE
017
010
011
012
012 and 017
NONE
017
010
011
012
012 and 017
NONE
016
013
014
015
014 and 016
NONE
016
013
014
015
014 and 016
NONE
016
013
014
015
014 and 016
NONE
018
019
NONE
018
019
NONE
018
019
NONE
017
010
011
012
012 and 017
NONE
017
010
011
012
012 and 017
NONE
016
013
014
015
014 and 016
NONE
016
013
014
015
014 and 016
NONE
018
019
NONE
018
019

LEGEND
FLA
Full Load Amps
HACR Heating, Air Conditioning and Refrigeration
IFM
Indoor (Evaporator) Fan Motor
LRA
Locked Rotor Amps
MCA
Minimum Circuit Amps
MOCP Maximum Overcurrent Protection
NEC
National Electrical Code
OFM
Outdoor (Condenser) Fan Motor
RLA
Rated Load Amps
*Used to determine minimum disconnect per NEC.
Fuse or HACR circuit breaker.
NOTES:
1. In compliance with NEC requirements for multimotor and combination load equipment (refer to NEC
Articles 430 and 440), the overcurrent protective device for the unit shall be fuse or HACR breaker.
Canadian units may be fuse or circuit breaker.
2. Unbalanced 3-Phase Supply Voltage
Never operate a motor where a phase imbalance in supply voltage is greater than 2%. Use the following formula to determine the percent of voltage imbalance.
% Voltage Imbalance
= 100 x

max voltage deviation from average voltage


average voltage

Example: Supply voltage is 460-3-60.


AB = 452 v
BC = 464 v
AC = 455 v
452 + 464 + 455
Average Voltage =
3
1371
=
3
= 457
Determine maximum deviation from average voltage.
(AB) 457 452 = 5 v
(BC) 464 457 = 7 v
(AC) 457 455 = 2 v

ELECTRIC HEAT
Nominal
kW
/
7.8/10.4
12.0/16.0
18.4/24.8
24.0/32.0
31.8/42.4
/
7.8/10.4
12.0/16.0
18.6/24.8
24.0/32.0
31.8/42.4
/
7.8/10.4
12.0/16.0
18.6/24.8
24.0/32.0
32.3/42.4

13.9
16.5
27.8
33.0
41.7

13.9
16.5
27.8
33.0
41.7

13.9
16.5
27.8
33.0
41.7

17.0
34.0

17.0
34.0

17.0
34.0
/
7.8/10.4
12.0/16.0
18.6/24.8
24.0/32.0
31.8/42.4
/
7.8/10.4
12.0/16.0
18.6/24.8
24.0/32.0
31.8/42.4

13.9
16.5
27.8
33.0
41.7

13.9
16.5
27.8
33.0
41.7

17.0
34.0

17.0
34.0

DISCONNECT
SIZE*

POWER SUPPLY

FLA

MCA

/
21.7/ 25.0
33.4/ 38.5
51.7/ 59.7
66.7/ 77.0
88.4/102.0
/
21.7/ 25.0
33.4/ 38.5
51.7/ 59.7
66.7/ 77.0
88.4/102.0
/
21.7/ 25.0
33.4/ 38.5
51.7/ 59.7
66.7/ 77.0
88.4/102.0

16.7
19.8
33.4
39.7
50.2

16.7
19.8
33.4
39.7
50.2

16.7
19.8
33.4
39.7
50.2

17.1
34.1

17.1
34.1

17.1
34.1
/
21.7/ 25.0
33.4/ 38.5
51.7/ 59.7
66.7/ 77.0
88.4/102.0
/
21.7/ 25.0
33.4/ 38.5
51.7/ 59.7
66.7/ 77.0
88.4/102.0

16.7
19.8
33.4
39.7
50.2

16.7
19.8
33.4
39.7
50.2

17.1
34.1

17.1
34.1

44.9/ 44.9
44.9/ 44.9
55.0/ 60.8
77.9/ 87.3
96.6/108.9
123.7/140.2
44.9/ 44.9
44.9/ 44.9
55.0/ 60.8
77.9/ 87.3
96.6/108.9
123.7/140.2
49.7/ 49.7
49.7/ 50.0
61.0/ 66.8
83.9/ 93.3
102.6/114.9
129.7/146.2
20.6
26.9
28.1
47.8
55.6
68.7
20.6
26.9
28.1
47.8
55.6
68.7
22.8
29.6
30.8
50.5
58.3
71.4
16.6
26.1
47.4
16.6
26.1
47.4
18.4
28.3
49.6
49.1/ 49.1
49.1/ 49.1
55.0/ 60.8
77.9/ 87.3
96.6/108.9
123.7/140.2
53.9/ 53.9
53.9/ 53.9
61.0/ 66.8
83.9/ 93.3
102.6/114.9
129.7/146.2
23.2
26.9
28.1
47.8
55.6
68.7
25.4
29.6
30.8
50.5
58.3
71.4
18.4
26.1
47.4
20.2
28.3
49.6

FLA

LRA

SINGLE POINT
BOX P/N
CRSINGLE---A00

48/ 48
48/ 48
51/ 56
72/ 81
89/101
114/130
48/ 48
48/ 48
51/ 56
72/ 81
89/101
114/130
53/ 53
53/ 53
56/ 61
77/ 86
94/106
119/135
22
25
28
44
51
63
22
25
28
44
51
63
24
27
31
46
54
66
18
24
44
18
24
44
20
26
46
52/ 52
52/ 52
52/ 56
72/ 81
89/101
114/130
57/ 57
57/ 57
57/ 61
77/ 86
94/106
119/135
24
25
28
44
51
63
27
27
31
46
54
66
19
24
44
21
26
46

234/234
234/234
234/234
234/234
234/234
234/234
234/234
234/234
234/234
234/234
234/234
234/234
277/277
277/277
277/277
277/277
277/277
277/277
110
110
110
110
110
110
110
110
110
110
110
110
132
132
132
132
132
132
99
99
99
99
99
99
116
116
116
277/277
277/277
277/277
277/277
277/277
277/277
320/320
320/320
320/320
320/320
320/320
320/320
151
151
151
151
151
151
173
173
173
173
173
173
111
111
111
128
128
128

006
006
007
009
009

006
006
007
007
009

006
007
007
007
009

006
006
006
006
008

006
006
006
006
008

006
006
006
006
008

006
006

006
006

006
006

006
006
007
007
009

006
007
007
007
009

006
006
006
006
008

006
006
006
006
008

006
006

006
006

MOCP
50/ 50
50/ 50
60/ 60
80/ 90**
100/110**
125/150**
50/ 50
50/ 50
60/ 60
80/ 90**
100/110**
125/150**
60/ 60
60/ 60
70/ 70**
90/100**
110/125**
150/150**
25
25
30
50
60
70**
25
25
30
50
60
70**
25
30
35
60
60
80**
20
25
45
20
25
45
20
30
45
60/ 60
60/ 60
60/ 60
80/ 90**
100/110**
125/150**
60/ 60
60/ 60
70/ 70**
90/100**
110/125**
150/150**
30
30
30
50
60
70**
30
30
35
60
60
80**
25
25
45
25
30
45

50TFF

HIGH

HEATER
MODEL NO.
CRHEATER---A00

Maximum deviation is 7 v.
Determine percent of voltage imbalance.
7
% Voltage Imbalance = 100 x
457
= 1.53%
This amount of phase imbalance is satisfactory as it is below the maximum allowable 2%.
IMPORTANT: If the supply voltage phase imbalance is more than 2%, contact your local electric utility
company immediately.
3. For units with power exhaust: If a single power source is to be used, size wire to include power
exhaust MCA and MOCP. Check MCA and MOCP when power exhaust is powered through the unit
(must be in accordance with NEC and/or local codes). Determine the new MCA including the power
exhaust using the following formula:
MCA New = MCA unit only + MCA of Power Exhaust
For example, using a 50TFF006---5 unit with MCA = 28.9 and MOCP = 35, with
CRPWREXH030A01 power exhaust.
MCA New = 28.9 amps + 1.6 amps = 30.5 amps
If the new MCA does not exceed the published MOCP, then MOCP would not change. The MOCP
in this example is 35 amps, the MCA New is below 35, therefore the MOCP is acceptable. If MCA
New is larger than the published MOCP, raise the MOCP to the next larger size. For separate
power, the MOCP for the power exhaust will be 15 amps per NEC.
POWER EXHAUST
PART NO.

MCA
(230 v)

MCA
(460 v)

MCA
(575 v)

CRPWREXH021A01
CRPWREXH022A01
CRPWREXH023A01
CRPWREXH028A01
CRPWREXH029A01
CRPWREXH030A01

N/A
3.4
N/A
1.7
N/A
1.6

0.68
N/A
1.4
N/A
0.7
N/A

N/A
1.32
N/A
0.68
N/A
0.64

MOCP
(for separate
power source)
15
15
15
15
15
15

79

Electrical data 50TFF (cont)


ELECTRICAL DATA UNITS WITH CONVENIENCE OUTLET (cont)
UNIT
50TFF

NOMINAL
V-PH-Hz

IFM
TYPE

VOLTAGE
RANGE
Min

Max

COMPRESSOR
(ea)
Qty

RLA

LRA

OFM (ea)
Qty

Hp

FLA

5.8

STD

50TFF

208/230-3-60

ALT

IFM
FLA

187

254

16

125

1/
4

1.4

7.5

HIGH

15

STD

2.6

012
460-3-60

575-3-60

ALT

414

508

62.5

1/4

0.7

3.4

HIGH

7.4

STD

2.6

ALT

518

632

6.3

50

1/4

0.7

HIGH

7.4

STD
208/230-3-60

3,4

10.6
187

254

19

156

1/
4

1.4

ALT

15

STD

4.8

014
460-3-60

414

508

75

1/4

0.7

ALT

7.4

4.8

STD
575-3-60

518

632

7.4

ALT

54

1/4

0.7
7.4

HEATER
MODEL NO.
CRHEATER---A00
NONE
017
010
012
012 and 017
010 and 012
NONE
017
010
012
012 and 017
010 and 012
NONE
017
010
012
012 and 017
010 and 012
NONE
013
014
015
014 and 016
013 and 015
NONE
013
014
015
014 and 016
013 and 015
NONE
013
014
015
014 and 016
013 and 015
NONE
018
019
018 and 019
NONE
018
019
018 and 019
NONE
018
019
018 and 019
NONE
017
010
012
012 and 017
010 and 012
NONE
017
010
012
012 and 017
010 and 012
NONE
013
014
015
014 and 016
013 and 015
NONE
013
014
015
014 and 016
013 and 015
NONE
018
019
018 and 019
NONE
018
019
018 and 019

LEGEND
FLA
Full Load Amps
HACR Heating, Air Conditioning and Refrigeration
IFM
Indoor (Evaporator) Fan Motor
LRA
Locked Rotor Amps
MCA
Minimum Circuit Amps
MOCP Maximum Overcurrent Protection
NEC
National Electrical Code
OFM
Outdoor (Condenser) Fan Motor
RLA
Rated Load Amps
*Used to determine minimum disconnect per NEC.
Fuse or HACR circuit breaker.
NOTES:
1. In compliance with NEC requirements for multimotor and combination load equipment (refer to NEC Articles 430 and 440), the overcurrent protective device for the unit shall be fuse or HACR breaker. Canadian units may be fuse or circuit breaker.
2. Unbalanced 3-Phase Supply Voltage
Never operate a motor where a phase imbalance in supply voltage is greater than 2%. Use the following
formula to determine the percent of voltage imbalance.
% Voltage Imbalance
= 100 x

max voltage deviation from average voltage


average voltage

Example: Supply voltage is 460-3-60.


AB = 452 v
BC = 464 v
AC = 455 v
452 + 464 + 455
Average Voltage =
3
1371
=
3
= 457
Determine maximum deviation from average voltage.

80

ELECTRIC HEAT
Nominal
kW
/
7.8/10.4
12.0/16.0
24.0/32.0
31.8/42.4
37.6/50.0
/
7.8/10.4
12.0/16.0
24.0/32.0
31.8/42.4
37.6/50.0
/
7.8/10.4
12.0/16.0
22.9/32
31.8/42.4
37.6/50.0

16.5
27.8
33.0
41.7
50.0

16.5
27.8
33.0
41.7
50.0

16.5
27.8
33.0
41.7
50.0

17.0
34.0
51.0

17.0
34.0
51.0

17.0
34.0
51.0
/
7.8/10.4
12.0/16.0
24.0/32.0
31.8/42.4
37.6/50.0
/
7.8/10.4
12.0/16.0
24.0/32.0
31.8/42.4
37.6/50.0

16.5
27.8
33.0
41.7
50.0

16.5
27.8
33.0
41.7
50.0

17.0
34.0
51.0

17.0
34.0
51.0

POWER SUPPLY

DISCONNECT
SIZE*

FLA

MCA

MOCP

FLA

LRA

SINGLE POINT
BOX P/N
CRSINGLE---A00

/
21.7/ 25.0
33.4/ 38.5
66.7/ 77.0
88.4/102.0
104.2/120.3
/
21.7/ 25.0
33.4/ 38.5
66.7/ 77.0
88.4/102.0
104.2/120.3
/
21.7/ 25.0
33.4/ 38.5
66.7/ 77.0
88.4/102.0
104.2/120.3

19.8
33.4
39.7
50.2
60.1

19.8
33.4
39.7
50.2
60.1

19.8
33.4
39.7
50.2
60.1

17.1
34.1
51.2

17.1
34.1
51.2

17.1
34.1
51.2
/
21.7/ 25.0
33.4/ 38.5
66.7/ 77.0
88.4/102.0
104.2/120.3
/
21.7/ 25.0
33.4/ 38.5
66.7/ 77.0
88.4/102.0
104.2/120.3

19.8
33.4
39.7
50.2
60.1

19.8
33.4
39.7
50.2
60.1

17.1
34.1
51.2

17.1
34.1
51.2

49.4/ 49.4
49.4/ 49.4
55.0/ 60.8
96.6/108.9
123.7/140.2
143.6/163.0
51.1/ 51.1
51.1/ 51.1
57.1/ 62.9
98.8/111.0
125.9/142.3
145.7/165.2
58.6/ 68.6
58.6/ 58.6
66.5/ 72.3
108.1/120.4
135.2/151.7
155.1/174.5
24.2
30.8
45.0
55.6
68.7
81.1
25.0
31.8
46.0
56.6
69.7
82.1
29.0
36.8
51.0
61.6
74.7
87.1
19.1
26.1
47.4
68.8
19.7
26.9
48.2
69.6
22.9
30.9
52.2
73.6
61.0/ 61.0
61.0/ 61.0
61.0/ 66.8
102.6/114.9
129.7/146.2
149.6/169.0
65.4/ 65.4
65.4/ 65.4
66.5/ 72.3
108.1/120.4
135.2/151.7
155.1/174.5
28.7
33.5
47.8
58.3
71.4
83.9
31.3
36.8
51.0
61.6
74.7
87.1
23.3
28.3
49.6
71.0
25.4
30.9
52.2
73.6

60/ 60
60/ 60
60/ 60
100/110**
125/150**
150/175**
60/ 60
60/ 60
60/ 60
100/125**
150/150**
150/175**
70/ 70**
70/ 70**
80/ 80**
110/125**
150/175**
175/175**
30
30
40
60
70**
90**
30
30
45
60
70**
90**
35
40
60
70**
80**
90**
25
25
45
70**
25
25
45
70**
25
35
50
80**
70/ 70**
70/ 70**
70/ 70**
110/125**
150/150**
150/175**
80/ 80**
80/ 80**
80/ 80**
110/125**
150/175**
175/175**
35
35
45
60
80**
90**
35
40
60
70**
80**
90**
30
30
45
80**
30
35
50
80**

52/ 52
52/ 52
52/ 56
89/101
114/130
132/151
54/ 54
54/ 54
54/ 58
91/103
116/131
134/152
63/ 63
63/ 63
63/ 67
99/111
124/140
143/161
26
28
44
51
63
75
26
29
45
52
64
76
31
34
49
57
69
80
20
24
44
63
21
25
44
64
25
28
48
68
65/ 65
65/ 65
65/ 65
94/106
119/135
138/156
70/ 70
70/ 70
70/ 70
99/111
124/140
143/161
30
31
46
54
66
77
33
34
49
57
69
80
25
26
46
65
27
28
48
68

302/302
302/302
302/302
302/302
302/302
302/302
321/321
321/321
321/321
321/321
321/321
321/321
369/369
369/369
369/369
369/369
369/369
369/369
151
151
151
151
151
151
190
190
190
190
190
190
184
184
184
184
184
184
121
121
121
121
152
152
152
152
148
148
148
148
364/364
364/364
364/364
364/364
364/364
364/364
383/383
383/383
383/383
383/383
383/383
383/383
176
176
176
176
176
176
215
215
215
215
215
215
129
129
129
129
160
160
160
160

011
011
012
015
015

011
011
012
015
015

012
012
012
015
015

011
011
011
014
014

011
011
011
014
014

011
011
014
014
014

011
011
014

011
011
014

011
011
014

012
012
012
015
015

012
012
012
015
015

011
011
011
014
014

011
011
014
014
014

011
011
014

011
011
014

(AB) 457 452 = 5 v


(BC) 464 457 = 7 v
(AC) 457 455 = 2 v
Maximum deviation is 7 v.
Determine percent of voltage imbalance.
7
% Voltage Imbalance = 100 x
457
= 1.53%
This amount of phase imbalance is satisfactory as it is below the maximum allowable 2%.
IMPORTANT: If the supply voltage phase imbalance is more than 2%, contact your local electric utility
company immediately.
3. For units with power exhaust: If a single power source is to be used, size wire to include power
exhaust MCA and MOCP. Check MCA and MOCP when power exhaust is powered through the unit
(must be in accordance with NEC and/or local codes). Determine the new MCA including the power
exhaust using the following formula:
MCA New = MCA unit only + MCA of Power Exhaust
For example, using a 50TFF006---5 unit with MCA = 28.9 and MOCP = 35, with CRPWREXH030A01
power exhaust.
MCA New = 28.9 amps + 1.6 amps = 30.5 amps
If the new MCA does not exceed the published MOCP, then MOCP would not change. The MOCP in
this example is 35 amps, the MCA New is below 35, therefore the MOCP is acceptable. If MCA New
is larger than the published MOCP, raise the MOCP to the next larger size. For separate power, the
MOCP for the power exhaust will be 15 amps per NEC.
POWER EXHAUST
PART NO.
CRPWREXH021A01
CRPWREXH022A01
CRPWREXH023A01
CRPWREXH028A01
CRPWREXH029A01
CRPWREXH030A01

MCA
(230 v)
N/A
3.4
N/A
1.7
N/A
1.6

MCA
(460 v)
0.68
N/A
1.4
N/A
0.7
N/A

MCA
(575 v)
N/A
1.32
N/A
0.68
N/A
0.64

MOCP
(for separate power source)
15
15
15
15
15
15

Typical wiring schematics 50TFF

50TFF

LEGEND
C
CAP
COMP
EQUIP
FPT
FU
GND
HC
HPS
IFC
IFM
LPS
LSM
OFM
OLR
P
PL
QT
SAT
TB
TDR
TRAN

Contactor, Compressor
Capacitor
Compressor Motor
Equipment
Freeze Up Protection Thermostat
Fuse
Ground
Heater Contactor
High-Pressure Switch
Indoor Fan Contactor
Indoor (Evaporator) Fan Motor
Low-Pressure/Loss-of-Charge Switch
Limit Switch (Motor)
Outdoor (Condenser) Fan Motor
Overload Relay
Plug
Plug Assembly
Quadruple Terminal
Supply Air Temperature Sensor
Terminal Block
Time Delay Relay
Transformer

Field Splice
Marked Wire
Terminal (Marked)
Terminal (Unmarked)
Terminal Block
Splice
Splice (Marked)
Factory Wiring

NOTES:
1. If any of the original wire furnished must
be replaced, it must be replaced with
type 90 C wire or its equivalent.
2. Three-phase motors are protected under
primary single-phasing conditions.
3. Use copper conductors only.
4. Use copper, copper clad aluminum or
aluminum conductors.
5. TRAN is wired for 230-v unit. If unit is to
be run with 208-v power supply disconnect BLK wire from 230-v tap (ORN) and
connect to 208-v tap (RED). Insulate end
of 230-v tap.
6. Unit will have either LSM or OLR, but not
both.

Field Control Wiring


Field Power Wiring
Accessory or Optional Wiring
To indicate common potential only;
not to represent wiring.

81

Typical wiring schematics 50TFF (cont)

50TFF

ECONOMI$ER IV WIRING 50TFF004-014

LEGEND
IAQ Indoor Air Quality
LA Low Ambient Lockout Device
POT Potentiometer
OAT Outdoor-Air Temperature
RAT Return-Air Temperature

NOTE:
Potentiometer Defaults Settings:
Power Exhaust Middle
Minimum Pos.
Fully Closed
DCV Max.
Middle
DCV Set
Middle
Enthalpy
C Setting

NOTES:
1. 620 ohm, 1 watt 5% resister should be removed only when using differential enthalpy or dry bulb.
2. If a separate field-supplied 24v transformer is used for the IAQ sensor
power supply, it cannot have the secondary of the transformer grounded.
3. For field-installed remote minimum position POT, remove black wire jumper
between P and P1 and set control minimum position POT to the minimum
position.

ECONOMI$ER2 WIRING 50TFF004-014


BLACK

4
3
5

BLUE
500 OHM
RESISTOR

8
VIOLET

NOTE 1
PINK

RUN
RED

NOTE 3

YELLOW

10

50HJ540573
ACTUATOR
ASSEMBLY

OPTIONAL CO 2
SENSOR 4 - 20 mA
OUTPUT

11
9
WHITE

DIRECT DRIVE
ACTUATOR

12

ECONOMISER2 PLUG
NOTES:
1. Switch on actuator must be in run position for economizer to operate.
2. PremierLink control requires that the standard 50HJ540569 outside-air sensor be replaced by either the CROASENR001A00 dry bulb sensor or HH57A077
enthalpy sensor.
3. 50HJ540573 actuator consists of the 50HJ540567 actuator and a harness with 500-ohm resistor.

82

905

CONVENIENCE OUTLET (OPTIONAL) 50TFF004-014


460V
C2 FOR 008-014 UNITS

RED

YEL BLU

LINE SIDE

GRA

C
H3

H1

H2

H4

11

21

RED
YEL

13

23

50TFF

TRAN4

BLU
GRA

23

240V
X4

X2

X1

X3

RED

SECONDARY
120V

H1

YEL BLU
H3

H2

X2

X3

GRA
208-230-1 ONLY

H4

TRAN4

RED

GRA

X4

600V
H2

H1

X1

BLK

WHT
SECONDARY
120V

TRAN4

X4

X2

GROUND FAULT
INTERRUPTER
CONVENIENCE
OUTLET
GFI - CO

X1

X3

GRN-YEL
GRN-YEL

SECONDARY
120V
SWITCH

BLK

FUSE

TEST
RESET

WHT

15 AMP

NON-FUSED DISCONNECT (OPTIONAL) 50TFF004-014

UNIT
DISCONNECT
FIELD
POWER
SUPPLY

BLK

BLK

YEL

YEL

BLU

BLU

TB
BLK

BLK

YEL

YEL

BLU

BLU

SINGLE POINT CONNECTION BOX

NOTE: Use copper conductors only.

83

Typical piping and wiring 50TFF004-014

50TFF

VERTICAL DISCHARGE DUCTING

HORIZONTAL DISCHARGE DUCTING

LEGEND
NEC National Electrical Code
*Factory-supplied, internally mounted disconnect
available as an option.

84

Guide specifications 50TFF004-014


Packaged Rooftop Electric Cooling Unit
Constant Volume Application
HVAC Guide Specifications
Size Range: 3 to 121/2 Tons, Nominal (Cooling)
4.4 to 51.0 kW, Nominal
(Accessory Electric Heating)

Part 1 General
1.01 SYSTEM DESCRIPTION
Outdoor rooftop mounted, electrically controlled
heating and cooling unit utilizing a hermetic compressor(s) for cooling duty. Unit shall discharge
supply air vertically or horizontally as shown on contract drawings.
1.02 QUALITY ASSURANCE
A. Unit shall be rated in accordance with ARI
Standards 210 or 360. Designed in accordance with
UL Standard 1995.
B. Unit shall be designed to conform to ASHRAE 15,
latest revision.
C. Unit shall be UL-tested and certified in accordance
with ANSI Z21.47 Standards and UL-listed and
certified under Canadian standards as a total package for safety requirements.
D. Roof curb shall be designed to conform to NRCA
Standards.
E. Insulation and adhesive shall meet NFPA 90A
requirements for flame spread and smoke
generation.
F. Unit casing shall be capable of withstanding
500-hour salt spray exposure per ASTM B117
(scribed specimen).
G. Unit shall be designed in accordance with
ISO 9001:2000, and shall be manufactured in a
facility registered to ISO 9001:2000.
H. Each unit shall be subjected to a completely automated run testing on the assembly line. Units contain a factory-supplied printout indicating tested
pressures, amperages, data, and inspectors; providing certification of the unit status at the time of
manufacture.
1.03 DELIVERY, STORAGE, AND HANDLING
Unit shall be stored and handled per manufacturers
recommendations.
Part 2 Products
2.01 EQUIPMENT (STANDARD)
A. General:
Factory assembled, single-piece heating and cooling
unit. Contained within the unit enclosure shall be all
factory wiring, piping, controls, refrigerant charge
(R-22), and special features required prior to field
start-up.

85

50TFF

Carrier Model Number:


50TFF

B. Unit Cabinet:
1. Unit cabinet shall be constructed of galvanized
steel, and shall be bonderized and coated with a
prepainted baked enamel finish on all externally
exposed surfaces.
2. Evaporator fan compartment interior cabinet
surfaces shall be insulated with a minimum
1/ -in. thick, 1 lb density, flexible fiberglass
2
insulation, neoprene coated on the air side.
3. Cabinet panels shall be easily removable for
servicing.
4. Holes shall be provided in the base rails for
rigging shackles to facilitate maneuvering and
overhead rigging.
5. Unit shall have a factory-installed, sloped condensate drain pan made of a non-corrosive
material, providing a minimum 3/4-in.-14 NPT
connection with both vertical and horizontal
drains, and shall comply with ASHRAE
Standard 62.
6. Unit shall have a factory-installed filter access
panel to provide filter access with tool-less
removal.
7. Unit shall have standard thru-the-bottom power
connection capability (accessory kit is required).
C. Fans:
1. Evaporator Fan:
a. Fan shall be direct or belt driven as shown
on the equipment drawings. Belt drive shall
include an adjustable-pitch motor pulley.
b. Fan wheel shall be double-inlet type with
forward-curved blades.
c. Bearings shall be sealed, permanently lubricated ball-bearing type for longer life and
lower maintenance.
2. Evaporator fan shall be made from steel with a
corrosion-resistant finish and shall be dynamically balanced.
3. Condenser fan shall be of the direct-driven (with
totally enclosed motors) propeller type and shall
discharge air vertically.
4. Condenser fan shall have aluminum blades
riveted to corrosion-resistant steel spiders and
shall be dynamically balanced.
5. Induced-draft blower shall be of the directdriven, single inlet, forward-curved centrifugal
type, made from steel with a corrosion-resistant
finish and shall be dynamically balanced.
D. Compressor(s):
1. Fully hermetic type, internally protected reciprocating (004-012) or scroll-type (014).
2. Factory mounted on rubber grommets and internally spring mounted for vibration isolation.

Guide specifications 50TFF004-014 (cont)

50TFF

3. On dual electrically and mechanically independent circuits (008-014).


E. Coils:
1. Standard evaporator and condenser coils shall
have aluminum lanced plate fins mechanically
bonded to seamless internally grooved copper
tubes with all joints brazed.
2. Dual compressor models (008-014), evaporator
coils are face-split design (circuit no. 1 on
bottom).
3. Testing:
a. Evaporator and condenser coils shall be
qualified to UL 1995 burst test at 2,200 psi.
b. Evaporator and condenser coils shall be leak
tested to 150 psig and pressure tested to
400 psig.
4. Optional Coils:
a. Optional pre-coated aluminum-fin coils shall
have a durable epoxy-phenolic coating to
provide protection in mildly corrosive coastal
environments. Coating shall be applied to
the aluminum fin stock prior to the fin
stamping process to create an inert barrier
between the aluminum fin and copper tube.
Epoxy-phenolic barrier shall minimize galvanic action between dissimilar metals.
b. Copper-fin coils shall be constructed of copper fins mechanically bonded to copper
tubes and copper tube sheets. Galvanized
steel tube sheets shall not be acceptable. A
polymer strip shall prevent coil assembly
from contacting the sheet metal coil pan to
minimize potential for galvanic corrosion
between coil and pan. All copper construction shall provide protection in moderate
coastal environments.
c. E-Coated aluminum-fin coils shall have a
flexible epoxy polymer coating uniformly
applied to all coil surface areas without material bridging between fins. Coating process
shall ensure complete coil encapsulation.
Color shall be high gloss black with gloss
60 deg of 65 to 90% per ASTM D523-89.
Uniform dry film thickness from 0.8 to
1.2 mil on all surface areas including fin
edges. Superior hardness characteristics of
2H per ASTM D3363-92A and cross-hatch
adhesion of 4B-5B per ASTM D3359-93.
Impact resistance shall be up to 160 in.-lb
(ASTM D2794-93). Humidity and water
immersion resistance shall be up to minimum 1000 and 250 hours respectively
(ASTM D2247-92 and ASTM D870-92).
Corrosion durability shall be confirmed
through testing to be no less than 1000
hours salt spray per ASTM B117-90. Coil
construction shall be aluminum fins mechanically bonded to copper tubes.

86

d. E-Coated copper-fin coils shall have a flexible epoxy polymer coating uniformly applied
to all coil surface areas without material
bridging between fins. Coating process shall
ensure complete coil encapsulation. Color
shall be high gloss black with gloss 60 deg
of 65 to 90% per ASTM D523-89. Uniform
dry film thickness from 0.8 to 1.2 mil on all
surface areas including fin edges. Superior
hardness characteristics of 2H per ASTM
D3363-92A and cross-hatch adhesion of
4B-5B per ASTM D3359-93. Impact resistance shall be up to 160 in.-lb (ASTM
D2794-93). Humidity and water immersion
resistance shall be up to minimum 1000 and
250 hours respectively (ASTM D2247-92
and ASTM D870-92). Corrosion durability
shall be confirmed through testing to be no
less than 1000 hours salt spray per ASTM
B117-90. Coil construction shall be copper
fins mechanically bonded to copper tubes
with copper tube sheets. Galvanized steel
tube sheets shall not be acceptable. A polymer strip shall prevent coil assembly from
contacting sheet metal coil pan to maintain
coating integrity and minimize corrosion
potential between coil and pan.
F. Refrigerant Components:
Refrigerant circuit components shall include:
1. Fixed orifice metering system (AcutrolTM
device).
2. Refrigerant filter drier.
3. Service gage connections on suction, discharge,
and liquid lines.
G. Filter Section:
1. Standard filter section shall consist of factoryinstalled, low velocity, throwaway 2-in. thick
fiberglass filters of commercially available sizes.
2. Filter face velocity shall not exceed 320 fpm at
nominal airflows.
3. Filter section should use only one size filter.
4. Filters shall be accessible through an access
panel with no-tool removal.
H. Controls and Safeties:
1. Unit Controls:
Unit shall be complete with self-contained lowvoltage control circuit protected by a fuse on
the 24-v transformer side (008-014 units have
a resettable circuit breaker).
2. Safeties:
a. Unit shall incorporate a solid-state compressor protector which provides anti-cycle reset
capability at the space thermostat, should
any of the following standard safety devices
trip and shut off compressor.
1) Compressor overtemperature, overcurrent.
2) Loss-of-charge/low-pressure switch.

905

f. Shall have baud communication rate of


38.4K or faster.
g. Shall be Internet ready.
h. Shall include an integrated economizer
controller.
i. If an economizer is specified the
EconoMi$er2 with the 4 to 20 mA actuator
and no microprocessor control is required.
2. Roof Curbs (Horizontal and Vertical):
a. Formed galvanized steel with wood nailer
strip and shall be capable of supporting
entire unit weight.
b. Permits installation and securing of ductwork
to curb prior to mounting unit on the curb.
3. Integrated Economizers:
a. Integrated integral modulating type capable
of simultaneous economizer and compressor
operation. During economizer operation, up
to two compressors on sizes 008-014 will
operate.
b. Available as a factory-installed option in vertical supply/return configuration only. (Available as a field-installed accessory for
dedicated horizontal and/or vertical supply
return configurations.)
c. Includes all hardware and controls to provide
cooling with outdoor air.
d. Equipped with low-leakage dampers, not to
exceed 2% leakage at 1 in. wg pressure
differential.
e. Capable of introducing up to 100% outdoor
air.
f. EconoMi$er IV and EconoMi$er2 shall be
equipped with a barometric relief damper
capable of relieving up to 100% return air.
g. Designed to close damper(s) during loss-ofpower situations with spring return built into
motor.
h. Dry bulb outdoor-air temperature sensor
shall be provided as standard. Outdoor air
sensor set point is adjustable and shall range
from 40 to 100 F. For the EconoMi$er IV,
the return air sensor, indoor enthalpy sensor,
and outdoor enthalpy sensor shall be provided as field-installed accessories to provide
enthalpy control, differential enthalpy control, and differential dry bulb temperature
control. For the EconoMi$er2, the enthalpy,
differential temperature (adjustable), and
differential enthalpy control shall be provided as field-installed accessories.
i. The EconoMi$er IV and EconoMi$er2 shall
have a gear-driven parallel blade design.
j. EconoMi$er IV microprocessor control shall
provide control of internal building pressure
through its accessory power exhaust

87

50TFF

3) Freeze-protection thermostat, evaporator coil.


4) High-pressure switch.
5) Automatic reset motor thermal overload
protector.
The lockout protection shall be easily disconnected at the control board, if necessary.
I. Operating Characteristics:
1. Unit shall be capable of starting and running at
115 F ambient outdoor temperature (125 F,
TFF009 and 014), meeting maximum load criteria of ARI Standard 210 or 360 at + 10%
voltage.
2. Compressor with standard controls shall be
capable of operation down to 25 F ambient
outdoor temperature.
J. Electrical Requirements:
All unit power wiring shall enter unit cabinet at a
single factory-predrilled location.
K. Motors:
1. Compressor motors shall be cooled by refrigerant gas passing through motor windings and
shall have line break thermal and current overload protection.
2. Evaporator-fan motor shall have permanently
lubricated bearings and inherent automaticreset thermal overload protection. Evaporator
motors are designed specifically for Carrier and
do not have conventional horsepower (HP) ratings listed on the motor nameplate. Motors are
designed and qualified in the air-over location
downstream of the cooling coil and carry a
maximum continuous bhp rating that is the
maximum application bhp rating for the motor;
no safety factors above that rating may be
applied.
3. Totally enclosed condenser-fan motor shall have
permanently lubricated bearings, and inherent
automatic-reset thermal overload protection.
L. Special Features:
Certain features are not applicable when the features designated * are specified. For assistance in
amending the specifications, contact your local
Carrier Sales Office.
* 1. Carrier PremierLink Controls:
a. Shall be available as a factory-installed or as
a field-installed accessory.
b. Shall work with Carrier Comfort Network
(CCN) and ComfortVIEW software.
c. Shall be compatible with ComfortLink
controllers.
d. Shall be ASHRAE 62-2001 compliant.
e. Shall accept a CO2 sensor in the conditioned
space Demand Control Ventilation (DCV)
ready.

50TFF

Guide specifications 50TFF004-014 (cont)

88

* 5. 100% Two-Position Damper:


a. Two-position damper package shall include
single blade damper and motor. Admits up
to 100% outdoor air.
b. Damper shall close upon indoor (evaporator)
fan shutoff.
c. Designed to close damper during loss of
power situations.
d. Equipped with 15% barometric relief
damper.
* 6. 25% Two-Position Damper:
a. Two-position damper package shall include
single blade damper and motor. Admits up
to 25% outdoor air.
b. Damper shall close upon indoor (evaporator)
fan shutoff.
* 7. Low Ambient Kit:
When used, kit allows unit to operate at lower
outdoor ambient temperatures down to 25 F.
* 8. Head Pressure Control Package:
Package consists of solid-state control and condenser-coil temperature sensor to maintain condensing temperature between 90 F and 110 F
at outdoor ambient temperatures down to
20 F by condenser-fan speed modulation or
condenser-fan cycling and wind baffles.
9. Electric Resistance Heaters and Single Point
Kits:
a. Open wire nichrome elements with all necessary safety operating controls.
b. UL listed and indicated on basic unit informative plate.
c. Available in multiples to match heating
requirements.
d. Single point kits available for each heater
when required.
*10. Electronic Programmable Thermostat:
Unit shall be capable of using deluxe fullfeatured electronic thermostat. Thermostat
shall use built-in compressor cycle delay control
for both heating and cooling duty. Thermostat
shall be capable of working with Carrier direct
digital controls.
11. Light Commercial Thermidistat device:
Field-installed wall-mounted thermostat is used
to control temperature and activation of the
Energy$Recycler device. The Thermidistat
device can be set for humidity settings from
50% to 90% relative humidity. Automatic
humidity control adjusts indoor humidity based
on the outdoor temperature sensor.

function. Factory set at 100%, with a range


of 0% to 100%.
k. EconoMi$er2 shall be capable of control
from a 4 to 20 mA signal through optional
4 to 20 mA design without microprocessor
control (required for PremierLink or third
party control interface).
l. EconoMi$er IV Microprocessor Occupied
Minimum Damper Position Setting maintains the minimum airflow into the building
during occupied period providing design
ventilation rate for full occupancy (damper
position during heating). A remote potentiometer may be used to override the set
point.
m. EconoMi$er IV Microprocessor Unoccupied
Minimum Damper Position Setting The
EconoMi$er IV dampers shall be completely
closed when the unit is in the occupied
mode.
n. EconoMi$er IV Microprocessor IAQ/DCV
Maximum Damper Position Setting Setting the maximum position of the damper
prevents the introduction of large amounts
of hot or cold air into the space. This position is intended to satisfy the base minimum
ventilation rate.
o. EconoMi$er IV Microprocessor IAQ/DCV
control modulates the outdoor-air damper
to provide ventilation based on the optional
2 to 10 vdc CO2 sensor input.
p. Compressor lockout sensor (opens at 35 F,
closes at 50 F).
q. Actuator shall be direct coupled to economizer gear, eliminating linkage arms and
rods.
r. Control LEDs:
1) When the outdoor air damper is capable
of providing free cooling, the Free
Cool LED shall illuminate.
2) The IAQ LED indicates when the module is on the DCV mode.
3) The EXH LED indicates when the
exhaust fan contact is closed.
s. Remote Minimum Position Control A
field-installed accessory remote potentiometer shall allow the outdoor air damper to be
opened or closed beyond the minimum
position in the occupied mode for modified
ventilation.
4. Manual Outdoor-Air Damper:
Manual damper package shall consist of
damper, birdscreen, and rainhood which can be
preset to admit up to 50% outdoor air for year
round ventilation.

905

905

The Energy$Recycler unit shall recover energy


from building exhaust air and precondition ventilation air to allow higher ventilation requirements and minimizing energy cost.
This accessory shall be available with the
following:
a. A mounting kit for the Energy$Recycler unit
for cantilever mounting off of the rooftop
unit with out the use of a slab or a roof curb.
b. A supplementary supply air fan kit to provide increased air movement into the 62AQ
unit.
c. A field-installed 460 v to 208/230 v transformer to provide power when the
208-230/1/60 62AQ060 or 100 size
Energy$Recycler unit is used with a 460 v
rooftop unit.
d. A field-installed 575-v to 208/230-v transformer to provide power when an
Energy$Recycler unit is used with a 575-v
unit.
23. Indoor Air Quality (CO2) Room Sensor
(EconoMi$er IV):
Sensor shall have the ability to provide demand
ventilation control through the EconoMi$er IV.
The IAQ sensor shall be wall mounted with an
LED display in parts per million. The set point
shall have adjustment capability.
24. Return Air CO2 Sensor (EconoMi$er IV):
Sensor shall have the ability to provide demand
ventilation control through the EconoMi$er IV.
The IAQ sensor shall be duct mounted. The set
point shall have adjustment capability.
25. Power Exhaust Accessory for EconoMi$er IV
and EconoMi$er2:
Power exhaust shall be used in conjunction with
EconoMi$er IV or EconoMi$er2 to provide system exhaust of up to 100% of return air (vertical only). The power exhaust is a field-installed
accessory (separate vertical and horizontal
design).
NOTE: Horizontal power exhaust is intended to
mount in return ductwork.
As the outdoor-air damper opens and closes,
both propeller fans are energized and deenergized through the Economi$er IV controller.
The set point is factory set at 100% of outdoorair, and is adjustable 0 to 100% to meet specific
job requirements. Available in 208/230-1-60 v
or 460-3-60 v. An LED light on the controller
indicates when the power exhaust is operating.
For the EconoMi$er2, the power exhaust shall
be controlled by the PremierLink or third
party controls.

89

50TFF

12. Humidistat:
Field-installed, wall-mounted humidistat is used
to control activation of the Energy$Recycler
device. The humidistat can be set for humidity
levels between 20% and 80% relative humidity.
*13. Thermostat and Subbase:
Thermostat and subbase shall provide staged
cooling and heating automatic (or manual)
changeover, fan control, and indicator light.
*14. Condenser Coil Hail Guard Assembly:
Hail guard shall protect against damage from
hail and flying debris.
15. Unit-Mounted, Non-Fused Disconnect Switch:
Switch shall be factory-installed, internally
mounted. NEC and UL approved non-fused
switch shall provide unit power shutoff. Shall be
accessible from outside the unit and shall provide power off lockout capability.
16. Convenience Outlet:
Outlet shall be factory-installed and internally
mounted with easily accessible 115-v female
receptacle. Shall include 15 amp GFI receptacle
with independent fuse protection. Voltage
required to operate convenience outlet shall be
provided by a factory-installed step-down transformer. Shall be accessible from outside the
unit.
17. Alternate (004-014) and High-Static Indoor
Fan Motor(s) and Drive(s) (004-012):
Alternate and High-static motor(s) and drive(s)
shall be factory-installed to provide additional
performance range.
18. Condenser Coil Grille:
The grille protects the condenser coil from
damage by large objects without increasing unit
clearances.
19. Compressor Cycle Delay:
Unit shall be prevented from restarting for minimum of 5 minutes after shutdown.
20. Thru-the-Bottom Utility Connectors:
Kit shall provide connectors to permit electrical
connections to be brought to the unit through
the basepan.
21. Fan/Filter Status Switch:
Switch shall provide status of indoor (evaporator) fan (ON/ OFF) or filter (CLEAN/DIRTY).
Status shall be displayed over communication
bus when used with direct digital controls or
with an indicator light at the thermostat.
22. Energy$Recycler unit:
The package shall be an outdoor rooftop, surface mounted, electronically controlled, air-toair heat pump unit utilizing a hermetic
compressor for cooling and heating duty.

Guide specifications 50TFF004-014 (cont)

50TFF

90

30. Indoor
Air
Quality
(CO2)
Sensor
(EconoMi$er2):
a. Shall have the ability to provide demand ventilation indoor air quality (IAQ) control
through the EconoMi$er2 with an IAQ
sensor.
b. The IAQ sensor shall be available in duct
mount, wall mount, and wall mount with
LED display. The set point shall have adjustment capability.
c. Requires EconoMi$er2, PremierLink or
Apollo control options.
31. Ultraviolet Germicidal Lamps:
Ultraviolet germicidal lamps are designed to
eliminate odor causing mold and fungus that
may develop in the wet area of the evaporator
section of the unit. The high output, low temperature germicidal lamps are field installed in
the evaporator section of the unit, aimed at the
evaporator coil and condensate pan. The short
wavelength ultraviolet light inhibits and kills
mold, fungus and microbial growth. The lamps
have an output rating at 45 F in 400 fpm airflow of 120 microwatts/cm2 at 1 meter.

26. Outdoor Air Enthalpy Sensor (EconoMi$er IV


or EconoMi$er2):
The outdoor air enthalpy sensor shall be used
with the EconoMi$er IV or EconoMi$er2
device to provide single enthalpy control. When
used in conjunction with a return air enthalpy
sensor, controller will provide differential
enthalpy control. The sensor allows the controller to determine if outside air is suitable for free
cooling.
27. Return Air Enthalpy Sensor (EconoMi$er IV or
EconoMi$er2):
The return air enthalpy sensor shall be used
with the EconoMi$er IV or EconoMi$er2
device. When used in conjunction with an outdoor air enthalpy sensor, the EconoMi$er IV or
EconoMi$er2 device will provide differential
enthalpy control.
28. Return Air Temperature Sensor (EconoMi$er
IV or EconoMi$er2):
The return air temperature sensor shall be used
with the EconoMi$er IV or EconoMi$er2
device. When used in conjunction with the standard outdoor air temperature sensor, the
EconoMi$er IV or EconoMi$er2 device will
provide differential temperature control.
29. Outdoor Air/Return Air Temperature Sensor
(adjustable) (EconoMi$er2):
Optional sensor uses the PremierLink control
to control outdoor air damper and compressor
operation.

905

Physical data 50TJ


016
208/230, 460 v
15
1500
90
200

UNIT 50TJ
NOMINAL CAPACITY (tons)
OPERATING WEIGHT (lb)
Economizer
Roof Curb
COMPRESSOR
Quantity...Model (Ckt 1, Ckt 2)

2...SR*942AE
2
90, 90
50/50

Number of Refrigerant Circuits


Oil (oz) (Ckt 1, Ckt 2)
Stages of Capacity Control (%)
REFRIGERANT TYPE
Expansion Device
Operating Charge (lb-oz)
Circuit 1*
Circuit 2
CONDENSER COIL

Rows...Fins/in.
Total Face Area (sq ft)
EVAPORATOR FAN
Quantity...Size (in.)
Type Drive
Nominal Cfm
Motor Hp
Motor Nominal Rpm

Nominal Fan Shaft Diameter (in.)


Belt, Quantity...Type...Length (in.)
Pulley Center Line Distance (in.)
Speed Change per Full Turn of
Movable Pulley Flange (rpm)
Movable Pulley Maximum Full Turns
From Closed Position
Factory Speed
Factory Speed Setting (rpm)
Fan Shaft Diameter at Pulley (in.)
HIGH-PRESSURE SWITCH (psig)
Cutout
Reset (Auto)
LOW-PRESSURE SWITCH (psig)
Cutout
Reset (Auto)
FREEZE PROTECTION THERMOSTAT (F)
Opens
Closes
OUTDOOR-AIR INLET SCREENS
Quantity...Size (in.)
RETURN-AIR FILTERS
Quantity...Size (in.)
POWER EXHAUST

024

028

18
1650
90
200
Scroll
1...SM120,
1...SR*782AE
2
110, 72
60/40
R-22
TXV

20
1775
90
200

25
1850
90
200

1...SM120,
1...SM110
2
110, 110
52/48

1...SM161,
1...SM120
2
112, 110
56/44

Low-Medium Static
High Static
Low-Medium Static
High Static
Low-Medium Static
High Static
Low-Medium Static
High Static
Low-Medium Static
High Static

Low-Medium Static
High Static

15-2
16-3
21-0
11-5
14-8
15-4
Cross-Hatched 3/8-in. Copper Tubes, Aluminum Lanced,
Aluminum Pre-Coated, or Copper Plate Fins
2...17
3...15
3...15
4...15
21.7
21.7
21.7
21.7
Propeller Type
10,400
9300
13,700
12,500
3...22
3...22
2...30
2...30
1/2...1050
1/2...1050
1...1075
1...1075
1100
1100
3400
3400
Cross-Hatched 3/8-in. Copper Tubes, Aluminum Lanced or
Copper Plate Fins, Face Split
2...17
3...15
3...15
4...15
17.5
17.5
17.5
17.5
Centrifugal Type
2...10 x 10
2...10 x 10
2...12 x 12
2...12 x 12
2...12 x 12
Belt
Belt
Belt
Belt
Belt
6000
6000
7200
8000
10,000
3.7
3.0
5
7.5
10
1725
1725
1745
1745
1740
8.7
[208/230,
575
v]
10.2
[208/230,
575 v]
4.25
3.45
5.90
9.5 [460 v]
11.8 [460 v]
56H
56H
184T
213T
215T

891-1179
1159-1429
910-1095
1002-1225
1066-1283
1227-1559

1069-1287
1193-1458
1332-1550
Ball
Ball
Ball
Ball
Ball
1550
1550
1550
1550
1550
3.1/4.1
4.3/5.3
4.9/5.9
5.4/6.6
4.9/5.9
3.7/4.7

4.9/5.9
5.4/6.6
4.9/5.9
7/
7/
11/8
13/8
13/8
8
8
6.0
6.4
9.4
9.4
8.0
5.2

8.0
7.9
6.4
13/16
13/16
17/16
17/16
17/16
1...BX...42
1...BX...45
1...BX...50
1...BX...53
2...BX...50
1...BX...42

1...BX...48
1...BX...50
2...BX...47
13.5-15.5
13.5-15.5
13.3-14.8
14.6-15.4
14.6-15.4
48
44
37
37
36
55

34
44
45
5
3.5
1035
1389
13/16

5
3.5
1296

13/16

5
3.5
1002
1178
17/16

5
3.5
1120
1328
17/16

5
3.5
1182
1470
17/16

426
320
27
44
30 5
45 5
Cleanable
2...20 x 25 x 1
1...20 x 20 x 1
Throwaway
4...20 x 20 x 2
4...16 x 20 x 2
1/ Hp, 208/230-460 v Motor Direct Drive, Propeller-Fan (Factory-Wired for 460 v)
2

LEGEND
Bhp Brake Horsepower
TXV Thermostatic Expansion Valve

NOTE: The 50TJ016-028 units have a low-pressure switch (standard) located on


the suction side.

*Circuit 1 uses the lower portion of condenser coil and lower portion of evaporator
coils; and Circuit 2 uses the upper portion of both coils.
The 50TJ028 units requires 2-in. industrial-grade filters capable of handling face
velocities of up to 625 ft/min (such as American Air Filter no. 5700 or equivalent).

91

50TJ

Motor Bearing Type


Maximum Allowable Rpm
Motor Pulley Pitch Diameter
Min/Max (in.)
Nominal Motor Shaft Diameter (in.)
Fan Pulley Pitch Diameter (in.)

020

10-13
10- 5

Rows...Fins/in.
Total Face Area (sq ft)
CONDENSER FAN
Nominal Cfm
Quantity...Diameter (in.)
Motor Hp...Rpm
Watts Input (Total)
EVAPORATOR COIL

Maximum Continuous Bhp


Motor Frame Size
Nominal Rpm High/Low
Fan Rpm Range

575 v

Physical data 50TJ (cont)


OPERATING AND RIGGING WEIGHTS
UNIT
50TJ

BASE UNIT OPERATING WEIGHTS*


020
024
lb
kg
lb
1650
748
1775

016
lb
1500

kg
680

028
kg
805

lb
1850

kg
839

*Base unit weight does not include electric heaters, copper coils, economizer, power exhaust, barometric relief or crating. See Options and Accessories table below for more information.
NOTE: For 016 and 020 unit sizes add 75 lb (34 kg) for domestic crating. For 024 and 028 unit sizes
add 135 lb (61 kg). For export crating add 500 lb (227 kg).

OPTIONS AND ACCESSORIES


(Weight Adders)
OPTION/
ACCESSORY

50TJ

Barometric Relief Damper


Power Exhaust
Electric Heater
EconoMi$er IV
Cu Condenser Coil
Cu Condenser and Evaporator Coils
Roof Curb (14-in. curb)
Horizontal Adapter Curb (Pre-Assembled)
MoistureMi$er Dehumidification Package
Horizontal Adapter Curb (Field-Assembled)
Hail Guard
LEGEND
Cu Copper

92

016
lb
50
85
50
90
150
280
200
250
40
343
60

kg
23
39
23
41
68
127
91
113
18
156
27

OPTION/ACCESSORY WEIGHTS
020
024
lb
kg
lb
kg
50
23
50
23
85
39
85
39
50
23
50
23
90
41
90
41
150
68
150
68
280
127
280
127
200
91
200
91
250
113
250
113
40
18
40
18
343
156
343
156
60
27
60
27

028
lb
50
85
50
90
150
280
200
250
40
343
60

kg
23
39
23
41
68
127
91
113
18
156
27

50TJ016
50TJ020

STD UNIT
WEIGHT
Lb
Kg
1500
680
1650
748

ECONOMIZER
WEIGHT
Lb
Kg
90
41
90
41

CORNER
(A)
Lb
Kg
374
170
380
172

50TJ

UNIT

CORNER
(B)
Lb
Kg
377
171
403
183

CORNER
(D)
Lb
Kg
375
170
405
184
mm
1054
1006

DIM A
Ft-in.
3-6
3-4

Direction of airflow.

Center of gravity.

mm
559
508

DIM C
Ft-in.
1-10
1- 8

5. Ductwork to be attached to accessory roof curb only.


6. Minimum clearance:
Rear: 7-0 (2134) for coil removal. This dimension can be reduced to
4-0 (1219) if conditions permit coil removal from the top.
Left side: 4-0 (1219) for proper condenser coil airflow.
Front: 4-0 (1219) for control box access.
Right side: 4-0 (1219) for proper operation of damper and power
exhaust if so equipped.
Top: 6-0 (1829) to assure proper condenser fan operation.
Local codes or jurisdiction may prevail.
7. With the exception of clearance for the condenser coil and the damper/
power exhaust as stated in Note #6, a removable fence or barricade requires
no clearance.
8. Dimensions are from outside of corner post. Allow 0-5/16 (8) on each side
for top cover drip edge.
9. See drawing 50TJ500352 for service option details.

4.

3.

mm
1096
1147

DIM B
Ft-in.
3-7
3-9

NOTES:
1. Refer to print for roof curb accessory dimensions.
2. Dimensions in [ ] are in millimeters.

CORNER
(C)
Lb
Kg
375
170
437
198

Base unit dimensions 50TJ024,028

93

94
50TJ024
50TJ028

UNIT

STD UNIT
WEIGHT
Lb
Kg
1775
805
1850
839

ECONOMIZER
WEIGHT
Lb
Kg
90
41
90
41

CORNER
(A)
Lb
Kg
412
187
419
190

50TJ

CORNER
(B)
Lb
Kg
416
189
421
191

CORNER
(C)
Lb
Kg
468
212
503
228
mm
989
963

DIM A
Ft-in.
3-3
3-2

mm
1090
1090

DIM B
Ft-in.
3-7
3-7

Direction of airflow.

Center of gravity.

mm
508
508

DIM C
Ft-in.
1-8
1-8

5. Ductwork to be attached to accessory roof curb only.


6. Minimum clearance:
Rear: 7-0 (2134) for coil removal. This dimension can be reduced to
4-0 (1219) if conditions permit coil removal from the top.
Left side: 4-0 (1219) for proper condenser coil airflow.
Front: 4-0 (1219) for control box access.
Right side: 4-0 (1219) for proper operation of damper and power
exhaust if so equipped.
Top: 6-0 (1829) to assure proper condenser fan operation.
Local codes or jurisdiction may prevail.
7. With the exception of clearance for the condenser coil and the damper/
power exhaust as stated in Note #6, a removable fence or barricade
requires no clearance.
8. Dimensions are from outside of corner post. Allow 0-5/16 (8) on each
side for top cover drip edge.
9. See drawing 50TJ500352 for service option details.
10. A 90 degree elbow must be installed on the supply ductwork below the
unit discharge for units equipped with electric heaters.

4.

3.

NOTES:
1. Refer to print for roof curb accessory dimensions.
2. Dimensions in [ ] are in millimeters.

CORNER
(D)
Lb
Kg
479
217
507
230

Base unit dimensions 50TJ024,028

CRRFCURB010A00
CRRFCURB011A00
CRRFCURB012A00

PKG. NO. REF.

CURB
HEIGHT
1 2 (305)
2- 0 (610)
2- 0 (610)
DESCRIPTION
Standard Curb 14 High
Standard Curb for Units Requiring High Installation
Side Supply and Return Curb for High Installation

50TJ

50TJ016-028

HORIZONTAL AND VERTICAL ROOF CURBS

Accessory dimensions 50TJ016-028

905

95

Accessory dimensions 50TJ016-028 (cont)


HORIZONTAL SUPPLY/RETURN ADAPTER INSTALLATION (50TJ016-024 Only)

3 1/2"

2" X 1/4
SUPPORT TYP.
STITCH WELDED

FULLY INSULATED
SUPPLY PLENUM
1" INSULATION
1 1/2 # DENSITY,
STICK PINNED & GLUED

14 3/4"

23"

50TJ

6"

NOTE: CRRFCURB013A00 is a fully factory preassembled


horizontal adapter and includes an insulated transition duct.
The pressure drop through the adapter curb is negligible.
For Horizontal return applications: The power exhaust and
barometric relief dampers must be installed in the return air
duct.

12" WIDE STANDING


SEAM PANELS

ACCESSORY
PACKAGE NO.
CRRFCURB013A00

96

CURB
HEIGHT
1-11
(584)

DESCRIPTION
Pre-Assembled Horizontal
Adapter Roof Curb

FACTORY-INSTALLED CONVENIENCE OUTLET (50TJ016-028)

LEGEND
K.O. Knockout

50TJ
97

Accessory dimensions 50TJ016-028 (cont)


BAROMETRIC RELIEF/POWER EXHAUST (50TJ016-028)

2'-1 5/8"

2'-2 1/16"

50TJ

1'-6 5/16"

FACTORY-INSTALLED NON-FUSED DISCONNECT (50TJ016-028)

98

Selection procedure (with 50TJ016 example)

76,000 Btuh
3.414 Btu/W

= 22,261 Watts of heat required


= 22.3 kW

Enter the Electric Resistance Heater Data table on


page 119 for the 50TJ016 at 230-3-60. The
34 kW electric heater most closely satisfies the heat
required.

IV Determine fan speed and motor horsepower


requirements at design conditions.
Enter Accessory/FIOP Static Pressure table on
page 118 at selected unit size and heater kW.
Find that at given air quantity (6000 cfm), pressure
loss is .09 in. wg.
Before entering the Fan Performance tables, calculate the total static pressure required based on unit
components. From the given find:
External static pressure
0.66 in. wg
34 kW Heater static pressure
0.09 in. wg
Total static pressure
0.75 in. wg
Enter Fan Performance table for unit 50TJ016 on
page 116. At 6000 cfm and 0.75 in. wg external
static pressure, the fan speed is 1068 rpm and the
watts are 2633. (Interpolation is necessary.) The
3.7 hp motor is suitable and a field-supplied drive is
required.
V Determine net cooling capacity.
Cooling capacities are gross capacities and do not
include indoor (evaporator) fan motor (IFM) heat.
Use the watts input power to the motor calculated in
Section IV above.
IFM watts = 2633
Determine net cooling capacity using the following
formula:
Net capacity = Gross capacity IFM heat
= 186,000 Btuh 2633 (3.414

Btuh
)
Watt

= 186,000 Btuh 8989 Btuh


= 177,011 Btuh
Net sensible capacity = 130,000 Btuh 8989 Btuh
= 121,011 Btuh
As demonstrated above, the 50TJ016 with the
34 kW electric heater and a field-supplied drive
meets the cooling capacity, sensible heating capacity, and heating capacity requirements.
NOTE: To obtain more sensible cooling, increase
quantity of air entering evaporator.

99

50TJ

I Determine cooling and heating requirements


at design conditions:
Given:
Cooling Capacity Required . . . . . . . .177,000 Btuh
Sensible Heat Capacity . . . . . . . . . .127,000 Btuh
Condenser Entering-Air
Temperature . . . . . . . . . . . . 95 F Edb/78 F Ewb
Evaporator Entering-Air
Temperature . . . . . . . . . . . . 80 F Edb/67 F Ewb
Evaporator Air Quantity . . . . . . . . . . . . . 6000 cfm
External Static Pressure . . . . . . . . . . . . 0.66 in. wg
Heating Capacity . . . . . . . . . . . . . . .76,000 Btuh
Power Supply (V-Ph-Hz). . . . . . . . . . . . . 230-3-60
Edb Entering dry bulb
Ewb Entering wet bulb
II Select unit based on required cooling capacity.
Enter cooling capacity table for 50TJ016 on
page 100 at condenser entering dry bulb temperature 95 F, air entering evaporator at 6000 cfm,
80 F edb and 67 F ewb. The 50TJ016 unit will provide a total cooling capacity of 186,000 Btuh, and a
sensible heating capacity of 130,000 Btuh. For
evaporator-air temperatures other than 80 F edb,
calculate sensible heat capacity correction as
required using the formula in the notes following the
Cooling Capacities tables.
NOTE: Unit ratings are gross capacities and do not
include the effect of evaporator-fan motor heat. To
calculate net capacities, see Step V.
III Select electric heat.
Heating load required is 76,000 Btuh.

Performance data 50TJ


COOLING CAPACITIES STANDARD UNITS
50TJ016 (15 Tons)
Temp (F)
Air Entering
Condenser
(Edb)
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW

75

85

95

105

115

117

120

Evaporator Air Quantity Cfm


4500
54/0.48

159
159
13.7
154
154
15.3
149
149
16.9
144
144
18.6
143
143
18.9
141
141
19.5

58/0.32
168
152
12.4
164
148
13.8
159
142
15.4
154
137
17.0
145
142
18.6
143
142
19.0
141
141
19.5

62/0.22
177
142
12.6
171
139
14.1
165
136
15.5
158
133
17.1
152
130
18.9
150
129
19.2
148
128
19.8

67/0.20
192
123
13.0
186
120
14.4
179
117
15.9
172
114
17.6
165
111
19.3
163
110
19.7
161
109
20.2

5250
72/0.19
209
103
13.3
202
100
14.8
195
98
16.3
187
95
18.0
179
92
19.8
178
91
20.2
175
90
20.7

Evaporator Air Ewb (F)/BF


76/0.24 80/0.04 54/0.54 58/0.39
225
240
171
171
85
69
171
150
13.6
13.9
12.5
12.6
219
233
166
172
83
66
166
151
15.5
15.4
13.9
14.0
210
226
161
164
80
64
161
155
16.7
17.3
15.5
15.5
201
216
156
156
78
61
156
156
18.4
18.7
17.2
17.1
193
207
150
151
75
58
150
151
20.2
20.6
18.9
18.9
191
205
149
149
74
57
149
149
20.5
20.9
19.2
19.2

147
148

147
148

19.8
19.8

62/0.25
182
151
12.7
175
148
14.1
169
145
15.7
162
142
17.2
156
137
19.0
154
136
19.4
152
135
19.9

67/0.23
197
130
13.1
190
127
14.5
183
124
16.0
176
121
17.7
168
118
19.5
167
117
19.8
164
116
20.4

72/0.21
214
108
13.4
207
105
14.9
199
102
16.5
191
99
18.1
183
96
19.9
181
96
20.3
179
95
20.8

76/0.23
229
88
13.7
222
86
15.2
214
83
16.8
205
81
18.5
196
78
20.3
194
77
20.7

80/0.04
246
69
14.0
237
67
15.5
229
64
17.1
222
62
19.1
210
58
20.7
208
58
21.0

72/0.25
221
116
13.5
213
113
15.1
205
111
16.6
197
108
18.3
188
104
20.1
186
104
20.4

76/0.25
236
93
13.9
228
91
15.3
220
88
17.0
211
85
18.6
201
82
20.5
199
82
20.8

80/0.03
253
70
14.1
247
68
16.3
235
65
17.3
225
62
18.9
215
59
20.8

50TJ016 (15 Tons) (cont)

50TJ

Temp (F)
Air Entering
Condenser
(Edb)
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW

75

85

95

105

115

117

120

BF
Edb
Ewb
kW
ldb
lwb
SHC
TC

Evaporator Air Quantity Cfm


6000
54/0.58
178
178
12.7
173
173
14.1
167
167
15.7
162
162
17.3
156
156
19.1
154
154
19.4
153
153
19.9

58/0.43
174
171
12.7
173
172
14.1
167
167
15.6
162
162
17.3
156
156
19.1
155
155
19.4
153
153
19.9

62/0.30
185
159
12.8
179
156
14.2
173
152
15.8
167
147
17.4
160
143
19.1
159
142
19.5
157
140
20.0

67/0.25
200
136
13.1
193
133
14.6
186
130
16.1
179
127
17.8
171
124
19.6
169
124
19.9
167
122
20.4

6750
72/0.23
218
112
13.5
210
109
15.0
203
106
16.6
194
104
18.2
186
101
20.0
184
100
20.4
181
99
20.9

LEGEND
Bypass Factor
Entering Dry-Bulb
Entering Wet-Bulb
Compressor Motor Power Input
Leaving Dry-Bulb
Leaving Wet-Bulb
Sensible Heat Capacity (1000 Btuh) Gross
Total Capacity (1000 Btuh) Gross

NOTES:
1. Direct interpolation is permissible. Do not extrapolate.
2. The following formulas may be used:
sensible capacity (Btuh)
1.10 x cfm

tldb =

tedb

tlwb =

Wet-bulb temperature corresponding to enthalpy of air


leaving evaporator coil (hlwb)

total capacity (Btuh)


4.5 x cfm
Where: hewb = Enthalpy of air entering evaporator coil

hlwb = hewb

100

Evaporator Air Ewb (F)/BF


76/0.24 80/0.04 54/0.62 58/0.48
233
250
183
179
91
70
183
179
13.8
14.1
12.8
12.7
227
244
178
178
89
68
178
178
15.8
16.2
14.2
14.2
217
232
173
173
86
64
173
173
16.9
17.2
15.8
15.8
208
223
168
167
83
61
168
167
18.5
18.9
17.4
17.4
199
213
160
160
80
59
160
160
20.4
20.7
19.2
19.2
197
211
159
159
79
58
159
159
20.8
21.1
19.6
19.6

157
157

157
157

20.1
20.1

62/0.36
183
161
12.8
183
161
14.3
177
157
15.9
171
152
17.5
165
145
19.3
163
144
19.7
161
142
20.2

67/0.28
203
142
13.2
196
139
14.7
189
137
16.2
181
133
17.9
173
130
19.6
171
129
20.0
169
128
20.5

3. The SHC is based on 80 F edb temperature of air entering evaporator coil.


Below 80 F edb, subtract (corr factor x cfm) from SHC.
Above 80 F edb, add (corr factor x cfm) to SHC.
BYPASS
FACTOR
(BF)

79
81

0.05
0.10
0.20
0.30
0.40
0.50
0.60
0.70

1.04
0.98
0.87
0.76
0.65
0.55
0.44
0.33

ENTERING AIR DRY-BULB TEMP (F)


78
77
76
75
under 75
82
83
84
85
over 85
Correction Factor
2.07
3.11
4.14
5.18
1.96
2.94
3.92
4.91
1.74
2.62
3.49
4.36
1.53
2.29
3.05
3.82
Use formula
shown below.
1.31
1.96
2.62
3.27
1.09
0.87
0.65

1.64
1.31
0.98

2.18
1.74
1.31

Interpolation is permissible.
Correction Factor = 1.10 x (1 BF) x (edb 80).

2.73
2.18
1.64

COOLING CAPACITIES STANDARD UNITS (cont)


50TJ016 (15 Tons) (cont)
Temp (F)
Air Entering
Condenser
(Edb)
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW

75

85

95

105

115

117

120

BF
Edb
Ewb
kW
ldb
lwb
SHC
TC

54/0.65
188
188
12.9
183
183
14.4
177
177
15.9
171
171
17.6
164
164
19.4
163
163
19.7
161
161
20.2

Evaporator Air Quantity Cfm


7500
Evaporator Air Ewb (F)/BF
58/0.52 62/0.41 67/0.30 72/0.28 76/0.27
183
193
206
223
239
183
170
148
120
95
12.8
13.0
13.2
13.6
13.9
183
187
199
215
233
183
167
145
117
94
14.4
14.4
14.7
15.1
15.9
177
181
191
207
222
177
161
142
114
90
15.9
16.0
16.3
16.7
17.0
171
175
183
199
213
171
154
138
111
87
17.6
17.7
18.0
18.4
18.7
164
169
175
190
203
164
146
135
108
84
19.4
19.5
19.7
20.2
20.5
163
167
173
188
201
163
145
134
107
84
19.7
19.9
20.0
20.5
20.9
161
165
170

161
143
133

20.3
20.4
20.6

LEGEND
Bypass Factor
Entering Dry-Bulb
Entering Wet-Bulb
Compressor Motor Power Input
Leaving Dry-Bulb
Leaving Wet-Bulb
Sensible Heat Capacity (1000 Btuh) Gross
Total Capacity (1000 Btuh) Gross

sensible capacity (Btuh)


1.10 x cfm

tldb =

tedb

tlwb =

Wet-bulb temperature corresponding to enthalpy of air


leaving evaporator coil (hlwb)

total capacity (Btuh)


4.5 x cfm
Where: hewb = Enthalpy of air entering evaporator coil

hlwb = hewb

3. The SHC is based on 80 F edb temperature of air entering evaporator coil.


Below 80 F edb, subtract (corr factor x cfm) from SHC.
Above 80 F edb, add (corr factor x cfm) to SHC.
BYPASS
FACTOR
(BF)

79
81

0.05
0.10
0.20
0.30
0.40
0.50
0.60
0.70

1.04
0.98
0.87
0.76
0.65
0.55
0.44
0.33

ENTERING AIR DRY-BULB TEMP (F)


78
77
76
75
under 75
82
83
84
85
over 85
Correction Factor
2.07
3.11
4.14
5.18
1.96
2.94
3.92
4.91
1.74
2.62
3.49
4.36
1.53
2.29
3.05
3.82
Use formula
shown below.
1.31
1.96
2.62
3.27
1.09
1.64
2.18
2.73
0.87
1.31
1.74
2.18
0.65
0.98
1.31
1.64

Interpolation is permissible.
Correction Factor = 1.10 x (1 BF) x (edb 80).

101

50TJ

NOTES:
1. Direct interpolation is permissible. Do not extrapolate.
2. The following formulas may be used:

80/0.03
256
70
14.2
249
68
16.3
237
65
17.3
228
62
19.0
217
59
20.9

Performance data 50TJ (cont)


COOLING CAPACITIES STANDARD UNITS (cont)
50TJ020 (18 Tons)
Temp (F)
Air Entering
Condenser
(Edb)
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW

75

85

95

105

115

117

120

Evaporator Air Quantity Cfm


5400
54/0.49
194
194
13.6
189
189
15.1
183
183
16.8
177
177
18.6
171
171
20.5
170
170
20.9
168
168
21.5

58/0.31
198
178
13.7
192
176
15.2
184
181
16.8
178
178
18.6
171
171
20.5
170
170
20.9
168
168
21.5

62/0.20
206
169
13.9
200
166
15.4
193
162
17.1
185
159
18.8
177
154
20.7
176
154
21.1
173
152
21.7

67/0.18
223
146
14.2
217
143
15.9
209
140
17.6
201
137
19.3
192
133
21.2
191
132
21.6
188
131
22.2

6000
72/0.16
243
121
14.6
235
118
16.3
227
115
18.0
218
112
19.8
209
109
21.8
207
108
22.1
204
107
22.7

Evaporator Air Ewb (F)/BF


76/0.19 80/0.05 54/0.53 58/0.35
260
277
200
203
99
79
200
191
15.0
15.2
13.7
13.8
252
269
195
195
97
76
195
195
16.6
16.9
15.3
15.3
243

189
190
94

189
190
18.4

17.0
17.0
234

183
185
91

183
185
20.2

18.8
18.6
224

176
177
88

176
177
22.1

20.7
20.7
222

175
175
87

175
175
22.5

21.1
21.1

173
173

173
173

21.7
21.7

62/0.23
210
177
14.0
204
174
15.7
196
170
17.2
189
166
18.9
181
161
20.8
180
160
21.2
177
159
21.8

67/0.19
227
152
14.4
220
149
16.0
212
146
17.6
204
143
19.4
195
139
21.3
193
138
21.7
191
137
22.3

72/0.17
246
125
14.7
239
123
16.4
230
120
18.1
221
116
19.9
212
113
21.8
210
112
22.2
207
111
22.8

76/0.19
263
102
15.1
255
100
16.8
246
97
18.5
237
94
20.3
226
90
22.2
224
90
22.6

80/0.05

72/0.22
255
138
15.0
247
135
16.6
238
132
18.3
228
128
20.1
218
125
22.1
216
124
22.5

76/0.21
272
109
15.3
263
107
17.0
254
104
18.7
244
100
20.6

80/0.04

50TJ020 (18 Tons) (cont)

50TJ

Temp (F)
Air Entering
Condenser
(Edb)
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW

75

85

95

105

115

117

120

BF
Edb
Ewb
kW
ldb
lwb
SHC
TC

Evaporator Air Quantity Cfm


7000
54/0.58
209
209
13.9
203
203
15.5
197
197
17.2
191
191
19.0
184
184
21.0
183
183
21.3
180
180
21.9

58/0.42
209
209
13.9
204
204
15.5
197
197
17.2
191
191
19.0
184
184
21.0
183
183
21.4
180
180
22.0

62/0.29
215
189
14.1
209
185
15.7
202
180
17.4
195
175
19.2
188
168
21.1
187
166
21.5
185
163
22.1

67/0.21
232
162
14.5
224
159
16.1
216
156
17.8
208
152
19.5
199
149
21.5
197
148
21.8
194
147
22.4

8000
72/0.20
251
132
14.9
243
129
16.5
235
126
18.2
225
123
20.0
215
119
22.0
214
118
22.4
210
117
23.0

LEGEND
Bypass Factor
Entering Dry-Bulb
Entering Wet-Bulb
Compressor Motor Power Input
Leaving Dry-Bulb
Leaving Wet-Bulb
Sensible Heat Capacity (1000 Btuh) Gross
Total Capacity (1000 Btuh) Gross

NOTES:
1. Direct interpolation is permissible. Do not extrapolate.
2. The following formulas may be used:
sensible capacity (Btuh)
1.10 x cfm

tldb =

tedb

tlwb =

Wet-bulb temperature corresponding to enthalpy of air


leaving evaporator coil (hlwb)

total capacity (Btuh)


4.5 x cfm
Where: hewb = Enthalpy of air entering evaporator coil

hlwb = hewb

102

Evaporator Air Ewb (F)/BF


76/0.20 80/0.05 54/0.62 58/0.48
268

216
217
106

216
217
15.2

14.1
14.1
260

211
211
103

211
211
16.9

15.7
15.7
251

204
204
100

204
204
18.7

17.4
17.4
241

197
197
97

197
197
20.5

19.2
19.2
230

190
190
94

190
190
22.4

21.1
21.1
228

188
188
93

188
188
22.7

21.5
21.5

186
186

186
186

22.1
22.1

62/0.36
221
198
14.2
215
192
15.8
209
185
17.6
202
177
19.3
194
170
21.2
192
171
21.7
190
172
22.2

67/0.23
236
171
14.5
228
168
16.2
220
165
17.9
211
161
19.6
202
158
21.6
200
157
22.0
197
156
22.5

3. The SHC is based on 80 F edb temperature of air entering evaporator coil.


Below 80 F edb, subtract (corr factor x cfm) from SHC.
Above 80 F edb, add (corr factor x cfm) to SHC.
BYPASS
FACTOR
(BF)

79
81

0.05
0.10
0.20
0.30
0.40
0.50
0.60
0.70

1.04
0.98
0.87
0.76
0.65
0.55
0.44
0.33

ENTERING AIR DRY-BULB TEMP (F)


78
77
76
75
under 75
82
83
84
85
over 85
Correction Factor
2.07
3.11
4.14
5.18
1.96
2.94
3.92
4.91
1.74
2.62
3.49
4.36
1.53
2.29
3.05
3.82
Use formula
shown below.
1.31
1.96
2.62
3.27
1.09
0.87
0.65

1.64
1.31
0.98

2.18
1.74
1.31

Interpolation is permissible.
Correction Factor = 1.10 x (1 BF) x (edb 80).

2.73
2.18
1.64

COOLING CAPACITIES STANDARD UNITS (cont)


50TJ020 (18 Tons) (cont)
Temp (F)
Air Entering
Condenser
(Edb)
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW

75

85

95

105

115

117

120

BF
Edb
Ewb
kW
ldb
lwb
SHC
TC

54/0.65
223
223
14.3
216
216
15.8
210
210
17.6
202
202
19.4
195
195
21.3
193
193
21.7
191
191
22.3

Evaporator Air Quantity Cfm


9000
Evaporator Air Ewb (F)/BF
58/0.53 62/0.40 67/0.25 72/0.23 76/0.23
223
228
239
258
275
223
202
181
144
113
14.3
14.4
14.6
15.0
15.4
217
222
231
250
266
217
194
177
141
110
15.9
16.0
16.3
16.7
17.1
210
215
223
241
257
210
187
174
138
107
17.6
17.7
18.0
18.4
18.8
202
207
214
231

202
184
170
134

19.4
19.5
19.7
20.2

195
196
204
221

195
192
166
131

21.3
21.4
21.7
22.2

193
194
202
219

193
192
166
130

21.7
21.7
22.0
22.6

191
191
199

191
191
164

22.3
22.3
22.6

LEGEND
Bypass Factor
Entering Dry-Bulb
Entering Wet-Bulb
Compressor Motor Power Input
Leaving Dry-Bulb
Leaving Wet-Bulb
Sensible Heat Capacity (1000 Btuh) Gross
Total Capacity (1000 Btuh) Gross

sensible capacity (Btuh)


1.10 x cfm

tldb =

tedb

tlwb =

Wet-bulb temperature corresponding to enthalpy of air


leaving evaporator coil (hlwb)

total capacity (Btuh)


4.5 x cfm
Where: hewb = Enthalpy of air entering evaporator coil

hlwb = hewb

3. The SHC is based on 80 F edb temperature of air entering evaporator coil.


Below 80 F edb, subtract (corr factor x cfm) from SHC.
Above 80 F edb, add (corr factor x cfm) to SHC.
BYPASS
FACTOR
(BF)

79
81

0.05
0.10
0.20
0.30
0.40
0.50
0.60
0.70

1.04
0.98
0.87
0.76
0.65
0.55
0.44
0.33

ENTERING AIR DRY-BULB TEMP (F)


78
77
76
75
under 75
82
83
84
85
over 85
Correction Factor
2.07
3.11
4.14
5.18
1.96
2.94
3.92
4.91
1.74
2.62
3.49
4.36
1.53
2.29
3.05
3.82
Use formula
shown below.
1.31
1.96
2.62
3.27
1.09
0.87
0.65

1.64
1.31
0.98

2.18
1.74
1.31

2.73
2.18
1.64

Interpolation is permissible.
Correction Factor = 1.10 x (1 BF) x (edb 80).

103

50TJ

NOTES:
1. Direct interpolation is permissible. Do not extrapolate.
2. The following formulas may be used:

80/0.05

Performance data 50TJ (cont)


COOLING CAPACITIES STANDARD UNITS (cont)
50TJ024 (20 Tons)
Temp (F)
Air Entering
Condenser
(Edb)
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW

75

85

95

105

115

117

120

Evaporator Air Quantity Cfm


6,000
54/0.48
217
217
15.1
212
212
16.9
206
206
18.9
199
199
20.8
192
192
23.0
191
191
23.5
189
189
24.2

58/0.31
222
199
15.2
217
194
17.2
208
197
18.8
202
190
20.9
194
192
22.9
191
191
23.5
189
189
24.2

62/0.21
232
189
15.4
226
185
17.3
217
181
19.0
209
177
21.1
200
173
23.3
199
172
23.7
196
170
24.4

67/0.19
252
163
15.8
244
159
17.6
236
156
19.5
227
152
21.6
218
149
23.8
216
148
24.2
213
147
25.0

7,000
72/0.17
274
136
16.2
266
133
18.0
257
129
20.0
247
126
22.0
237
122
24.3
235
121
24.8
232
120
25.5

Evaporator Air Ewb (F)/BF


76/0.22 80/0.05 54/0.54 58/0.37
294
316
227
231
112
90
227
217
16.6
17.0
15.3
15.4
285
306
222
225
109
87
222
211
18.4
18.8
17.1
17.3
276
295
215
216
106
84
215
213
20.4
20.8
19.0
19.0
265
285
208
209
103
80
208
209
22.5
22.9
21.0
21.0
254

202
202
99

202
202
24.8

23.2
23.2
252

200
200
99

200
200
25.2

23.8
23.8
249

197
198
98

197
198
25.9

24.5
24.5

62/0.25
238
202
15.5
231
198
17.3
223
194
19.2
215
189
21.2
207
183
23.5
205
182
23.9
203
181
24.6

67/0.21
254
172
15.9
250
170
17.7
241
166
19.6
232
163
21.7
222
159
23.9
220
158
24.4
217
156
25.1

72/0.19
281
143
16.4
272
140
18.2
262
136
20.1
252
132
22.2
242
129
24.5
240
128
24.9
236
127
25.6

76/0.21
297
115
16.5
291
113
18.6
281
110
20.5
270
107
22.6
259
103
24.9
257
102
25.3

80/0.04
322
91
17.2
312
88
19.0
301
84
21.0

72/0.23
290
155
16.6
281
152
18.4
270
148
20.3
260
145
22.4
249
141
24.7
246
140
25.1
243
139
25.8

76/0.23
307
123
16.7
300
121
18.8
289
117
20.8
278
114
22.8
266
110
25.1
263
109
25.6

80/0.04

50TJ024 (20 Tons) (cont)

50TJ

Temp (F)
Air Entering
Condenser
(Edb)
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW

75

85

95

105

115

117

120

BF
Edb
Ewb
kW
ldb
lwb
SHC
TC

Evaporator Air Quantity Cfm


8,000
54/0.58
236
236
15.5
231
231
17.5
223
223
19.2
216
216
21.3
208
208
23.5
207
207
24.0
204
204
24.7

58/0.43
238
232
15.5
230
230
17.3
223
223
19.2
216
216
21.3
209
209
23.5
207
207
24.0
205
205
24.7

62/0.30
241
211
15.6
237
209
17.4
229
203
19.3
221
197
21.4
213
190
23.7
212
188
24.1
209
185
24.8

67/0.23
259
181
15.9
254
179
17.8
245
176
19.8
236
172
21.8
226
168
24.0
224
167
24.5
221
166
25.2

9,000
72/0.21
286
149
16.5
276
146
18.3
267
142
20.2
256
139
22.3
246
135
24.6
243
134
25.0
240
133
25.7

LEGEND
Bypass Factor
Entering Dry-Bulb
Entering Wet-Bulb
Compressor Motor Power Input
Leaving Dry-Bulb
Leaving Wet-Bulb
Sensible Heat Capacity (1000 Btuh) Gross
Total Capacity (1000 Btuh) Gross

NOTES:
1. Direct interpolation is permissible. Do not extrapolate.
2. The following formulas may be used:
sensible capacity (Btuh)
1.10 x cfm

tldb =

tedb

tlwb =

Wet-bulb temperature corresponding to enthalpy of air


leaving evaporator coil (hlwb)

total capacity (Btuh)


4.5 x cfm
Where: hewb = Enthalpy of air entering evaporator coil

hlwb = hewb

104

Evaporator Air Ewb (F)/BF


76/0.22 80/0.04 54/0.62 58/0.48
302
328
244
244
119
91
244
244
16.6
17.3
15.7
15.7
296

237
238
117

237
238
18.7

17.5
17.6
285

231
230
114

231
230
20.6

19.5
19.4
274

222
223
110

222
223
22.7

21.4
21.5
263

214
214
107

214
214
25.0

23.7
23.7
260

213
213
106

213
213
25.5

24.2
24.2

210
210

210
210

24.9
24.9

62/0.35
250
222
15.8
243
216
17.6
235
209
19.5
228
202
21.6
220
193
23.9
219
191
24.2
215
193
25.0

67/0.24
267
192
16.1
258
189
18.0
249
185
19.8
239
181
21.9
229
177
24.2
227
176
24.6
224
175
25.3

3. The SHC is based on 80 F edb temperature of air entering evaporator coil.


Below 80 F edb, subtract (corr factor x cfm) from SHC.
Above 80 F edb, add (corr factor x cfm) to SHC.
BYPASS
FACTOR
(BF)

79
81

0.05
0.10
0.20
0.30
0.40
0.50
0.60
0.70

1.04
0.98
0.87
0.76
0.65
0.55
0.44
0.33

ENTERING AIR DRY-BULB TEMP (F)


78
77
76
75
under 75
82
83
84
85
over 85
Correction Factor
2.07
3.11
4.14
5.18
1.96
2.94
3.92
4.91
1.74
2.62
3.49
4.36
1.53
2.29
3.05
3.82
Use formula
shown below.
1.31
1.96
2.62
3.27
1.09
0.87
0.65

1.64
1.31
0.98

2.18
1.74
1.31

Interpolation is permissible.
Correction Factor = 1.10 x (1 BF) x (edb 80).

2.73
2.18
1.64

COOLING CAPACITIES STANDARD UNITS (cont)


50TJ024 (20 Tons) (cont)
Temp (F)
Air Entering
Condenser
(Edb)
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW

75

85

95

105

115

117

120

BF
Edb
Ewb
kW
ldb
lwb
SHC
TC

54/0.65
250
250
15.8
243
243
17.6
236
236
19.5
228
228
21.6
220
220
23.9
218
218
24.3
215
215
25.1

Evaporator Air Quantity Cfm


10,000
Evaporator Air Ewb (F)/BF
58/0.52 62/0.40 67/0.26 72/0.24 76/0.24
250
256
267
294
314
250
227
200
161
127
15.8
15.9
16.1
16.7
17.1
244
249
262
284
303
244
220
198
158
124
17.8
17.7
18.0
18.5
18.9
236
241
252
274
292
236
212
194
154
121
19.5
19.7
19.9
20.4
20.9
228
234
242
263
281
228
203
190
151
117
21.6
21.8
22.0
22.5
22.9
220
223
232
251
268
220
207
186
147
113
23.9
23.9
24.2
24.7
25.2
218
221
230
249
266
218
205
185
146
112
24.3
24.4
24.7
25.2
25.6
215
218
226
245

215
203
183
145

25.1
25.1
25.4
25.9

LEGEND
Bypass Factor
Entering Dry-Bulb
Entering Wet-Bulb
Compressor Motor Power Input
Leaving Dry-Bulb
Leaving Wet-Bulb
Sensible Heat Capacity (1000 Btuh) Gross
Total Capacity (1000 Btuh) Gross

sensible capacity (Btuh)


1.10 x cfm

tldb =

tedb

tlwb =

Wet-bulb temperature corresponding to enthalpy of air


leaving evaporator coil (hlwb)

total capacity (Btuh)


4.5 x cfm
Where: hewb = Enthalpy of air entering evaporator coil

hlwb = hewb

3. The SHC is based on 80 F edb temperature of air entering evaporator coil.


Below 80 F edb, subtract (corr factor x cfm) from SHC.
Above 80 F edb, add (corr factor x cfm) to SHC.
BYPASS
FACTOR
(BF)

79
81

0.05
0.10
0.20
0.30
0.40
0.50
0.60
0.70

1.04
0.98
0.87
0.76
0.65
0.55
0.44
0.33

ENTERING AIR DRY-BULB TEMP (F)


78
77
76
75
under 75
82
83
84
85
over 85
Correction Factor
2.07
3.11
4.14
5.18
1.96
2.94
3.92
4.91
1.74
2.62
3.49
4.36
1.53
2.29
3.05
3.82
Use formula
shown below.
1.31
1.96
2.62
3.27
1.09
0.87
0.65

1.64
1.31
0.98

2.18
1.74
1.31

2.73
2.18
1.64

Interpolation is permissible.
Correction Factor = 1.10 x (1 BF) x (edb 80).

105

50TJ

NOTES:
1. Direct interpolation is permissible. Do not extrapolate.
2. The following formulas may be used:

80/0.04

Performance data 50TJ (cont)


COOLING CAPACITIES STANDARD UNITS (cont)
50TJ028 (25 Tons)
Temp (F)
Air Entering
Condenser
(Edb)
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW

75

85

95

105

115

117

120

Evaporator Air Quantity Cfm


7,000
54/0.44

249
249
21.3
244
244
23.6
237
237
25.9
229
229
28.6
228
228
29.1
226
226
30.0

58/0.26
256
243
19.3
251
238
21.3
245
230
23.5
238
233
25.9
231
225
28.6
230
225
29.1
226
225
30.0

62/0.13
270
229
20.0
265
226
21.7
257
223
24.1
247
218
26.3
237
213
28.9
236
212
29.4
232
211
30.3

67/0.12
298
198
20.3
289
194
22.4
279
190
24.6
269
185
27.0
258
181
29.6
256
180
30.2
252
179
30.9

8,000
72/0.12
325
164
21.0
315
160
23.1
306
156
25.6
293
152
27.8
283
148
30.3
279
147
31.0
276
145
31.8

Evaporator Air Ewb (F)/BF


76/0.19 80/0.01 54/0.49 58/0.32
349
370
266
268
133
106
266
251
21.6
22.2
19.5
19.6
340
361
260
262
130
103
260
254
24.3
24.4
21.6
21.6
328
349
254
256
127
99
254
249
26.2
26.7
23.8
23.9
315
336
246
247
122
95
246
245
28.5
29.2
26.3
26.3
302
322
238
239
119
91
238
239
31.2
31.9
28.9
28.9
299

237
237
118

237
237
31.7

29.4
29.5

234
234

234
234

30.3
30.3

62/0.15
280
246
19.9
272
243
22.0
262
238
24.1
253
233
26.5
243
228
29.1
241
227
29.6
238
225
30.5

67/0.14
304
209
20.5
294
205
22.5
284
201
24.8
274
197
27.2
264
193
29.7
260
192
30.4
257
190
31.1

72/0.13
324
168
20.9
321
167
23.3
310
163
25.5
298
159
28.0
286
155
30.6
283
154
31.2
280
152
32.0

76/0.17
352
137
21.8
344
135
23.9
332
131
26.2
319
127
28.7
306
123
31.4
304
122
31.9

80/0.00
379
107
22.4
367
104
24.6
355
100
26.9
343
96
29.5
328
91
32.1

72/0.15
341
186
21.5
330
182
23.6
319
177
25.8
306
173
28.3
293
168
30.9
291
168
31.4

76/0.17
365
147
22.1
354
143
24.2
341
139
26.5
328
135
29.0
315
131
31.7

80/0.00
390
108
22.7
378
105
24.9
364
101
27.2
352
97
29.8

50TJ028 (25 Tons) (cont)

50TJ

Temp (F)
Air Entering
Condenser
(Edb)
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW

75

85

95

105

115

117

120

BF
Edb
Ewb
kW
ldb
lwb
SHC
TC

Evaporator Air Quantity Cfm


9,000
54/0.53
277
277
19.8
271
271
22.2
263
263
24.1
255
255
26.5
247
247
29.1
244
244
29.7
241
241
30.6

58/0.37
276
269
19.5
272
264
21.9
263
263
24.1
255
255
26.5
246
246
29.2
244
244
29.7
242
242
30.6

62/0.18
286
261
20.0
277
257
22.1
268
251
24.3
258
246
26.6
249
239
29.3
247
237
29.8
244
235
30.7

67/0.15
310
221
20.6
300
217
22.7
289
213
24.9
278
208
27.3
267
204
30.0
265
203
30.4
261
201
31.3

10,000
72/0.14
336
178
21.3
326
175
23.4
316
171
25.9
302
166
28.1
290
162
30.8
288
161
31.3

LEGEND
Bypass Factor
Entering Dry-Bulb
Entering Wet-Bulb
Compressor Motor Power Input
Leaving Dry-Bulb
Leaving Wet-Bulb
Sensible Heat Capacity (1000 Btuh) Gross
Total Capacity (1000 Btuh) Gross

NOTES:
1. Direct interpolation is permissible. Do not extrapolate.
2. The following formulas may be used:
sensible capacity (Btuh)
1.10 x cfm

tldb =

tedb

tlwb =

Wet-bulb temperature corresponding to enthalpy of air


leaving evaporator coil (hlwb)

total capacity (Btuh)


4.5 x cfm
Where: hewb = Enthalpy of air entering evaporator coil

hlwb = hewb

106

Evaporator Air Ewb (F)/BF


76/0.17 80/0.00 54/0.57 58/0.41
361
385
286
284
142
108
286
284
22.0
22.6
20.0
20.2
349
373
278
278
139
104
278
278
24.1
24.8
22.1
22.1
337
360
270
270
135
100
270
270
26.4
27.1
24.4
24.4
326
346
261
262
132
96
261
262
29.0
29.6
26.8
26.8
311

253
253
127

253
253
31.5

29.3
29.3
308

251
251
126

251
251
32.1

30.0
30.0

248
248

248
248

30.8
30.8

62/0.23
291
274
20.2
282
269
22.2
273
262
24.4
264
254
26.9
255
245
29.6
253
243
30.0
250
239
31.0

67/0.16
314
232
20.8
304
228
22.8
293
223
25.1
282
219
27.5
270
214
30.1
268
213
30.6
264
212
31.5

3. The SHC is based on 80 F edb temperature of air entering evaporator coil.


Below 80 F edb, subtract (corr factor x cfm) from SHC.
Above 80 F edb, add (corr factor x cfm) to SHC.
BYPASS
FACTOR
(BF)

79
81

0.05
0.10
0.20
0.30
0.40
0.50
0.60
0.70

1.04
0.98
0.87
0.76
0.65
0.55
0.44
0.33

ENTERING AIR DRY-BULB TEMP (F)


78
77
76
75
under 75
82
83
84
85
over 85
Correction Factor
2.07
3.11
4.14
5.18
1.96
2.94
3.92
4.91
1.74
2.62
3.49
4.36
1.53
2.29
3.05
3.82
Use formula
shown below.
1.31
1.96
2.62
3.27
1.09
0.87
0.65

1.64
1.31
0.98

2.18
1.74
1.31

Interpolation is permissible.
Correction Factor = 1.10 x (1 BF) x (edb 80).

2.73
2.18
1.64

COOLING CAPACITIES STANDARD UNITS (cont)


50TJ028 (25 Tons) (cont)
Temp (F)
Air Entering
Condenser
(Edb)
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW

75

85

95

105

115

117

120

BF
Edb
Ewb
kW
ldb
lwb
SHC
TC

54/0.61
295
295
20.3
288
288
22.5
278
278
24.6
269
269
27.0
259
259
29.7
257
257
30.3
254
254
31.1

Evaporator Air Quantity Cfm


11,250
Evaporator Air Ewb (F)/BF
58/0.47 62/0.30 67/0.16 72/0.17 76/0.17
295
298
319
342
367
295
285
245
193
151
20.3
20.4
20.9
21.2
21.5
287
289
310
334
359
287
278
241
190
148
22.4
22.4
23.1
23.7
24.4
278
280
318
323
346
278
269
150
186
144
24.6
24.7
30.0
26.0
26.7
269
272
285
310
332
269
259
232
182
140
27.0
27.1
27.6
28.4
29.1
260
262
273
297
318
260
247
227
177
136
29.6
29.8
30.2
31.1
31.8
257
261
271
294

257
245
226
176

30.3
30.3
30.7
31.6

254
257
267

254
242
224

31.1
31.3
31.6

LEGEND
Bypass Factor
Entering Dry-Bulb
Entering Wet-Bulb
Compressor Motor Power Input
Leaving Dry-Bulb
Leaving Wet-Bulb
Sensible Heat Capacity (1000 Btuh) Gross
Total Capacity (1000 Btuh) Gross

sensible capacity (Btuh)


1.10 x cfm

tldb =

tedb

tlwb =

Wet-bulb temperature corresponding to enthalpy of air


leaving evaporator coil (hlwb)

total capacity (Btuh)


4.5 x cfm
Where: hewb = Enthalpy of air entering evaporator coil

hlwb = hewb

3. The SHC is based on 80 F edb temperature of air entering evaporator coil.


Below 80 F edb, subtract (corr factor x cfm) from SHC.
Above 80 F edb, add (corr factor x cfm) to SHC.
BYPASS
FACTOR
(BF)

79
81

0.05
0.10
0.20
0.30
0.40
0.50
0.60
0.70

1.04
0.98
0.87
0.76
0.65
0.55
0.44
0.33

ENTERING AIR DRY-BULB TEMP (F)


78
77
76
75
under 75
82
83
84
85
over 85
Correction Factor
2.07
3.11
4.14
5.18
1.96
2.94
3.92
4.91
1.74
2.62
3.49
4.36
1.53
2.29
3.05
3.82
Use formula
shown below.
1.31
1.96
2.62
3.27
1.09
1.64
2.18
2.73
0.87
1.31
1.74
2.18
0.65
0.98
1.31
1.64

Interpolation is permissible.
Correction Factor = 1.10 x (1 BF) x (edb 80).

107

50TJ

NOTES:
1. Direct interpolation is permissible. Do not extrapolate.
2. The following formulas may be used:

80/0.00
392
108
21.9
384
106
25.3

Performance data 50TJ (cont)


COOLING CAPACITIES UNITS WITH MOISTUREMI$ER OPTION
50TJ016 (15 Tons)
Temp (F)
Air Entering
Condenser
(Edb)
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW

75

85

95

105

115

117

120

Evaporator Air Quantity Cfm


4500
54/0.41

58/0.30

62/0.25
166
122
12.6
157
115
13.9
149
107
15.2
139
99
16.6
130
90
18.0
128
88
18.3
125
85
18.7

67/0.23
182
104
13.0
174
97
14.4
164
88
15.6
154
79
17.1
143
70
18.5
141
68
18.9
138
65
19.2

5250
72/0.22
199
85
13.4
191
77
14.9
180
68
16.1
169
58
17.6
159
48
18.9
156
46
19.4
153
43
19.8

Evaporator Air Ewb (F)/BF


76/0.25 80.0.04 54/0.48 58/0.35
215
231

162
69
51

142
13.8
14.1

12.5
206
222

153
60
43

134
15.4
15.8

13.8
194
210

145
50
33

127
16.5
16.9

15.1
183
198

136
41
22

118
18.0
18.4

16.5
173
186

127
30
11

109
19.4
19.9

17.9
169
183

125
28
9

106
19.9
20.3

18.2
165
179
118
122
25
5
118
102
20.2
20.7
18.4
18.5

62/0.28
171
131
12.7
163
124
14.0
154
116
15.4
144
107
16.8
134
98
18.2
132
96
18.5
128
92
18.8

67/0.26
187
111
13.1
179
103
14.6
168
94
15.8
158
85
17.2
147
75
18.7
145
73
19.0
141
70
19.4

72/0.24
205
90
13.5
196
81
15.1
185
72
16.3
174
62
17.7
163
51
19.1
160
49
19.5
156
46
19.9

76/0.34
221
70
13.9
211
60
15.5
200
50
16.7
188
40
18.1
177
29
19.5
173
28
20.0
169
24
20.3

80/0.03
237
52
14.2
226
42
15.6
216
32
17.2
202
21
18.5
191
10
20.0
187
7
20.3
182
3
20.7

72/0.29
213
98
13.7
203
88
15.3
191
79
16.5
180
68
17.9
168
57
19.4
165
55
19.7
161
51
20.0

76/0.31
228
75
14.1
218
65
15.7
206
55
16.8
194
44
18.3
182
33
19.9
178
30
20.1
174
26
20.5

80/0.03
245
52
14.4
234
42
16.1
221
31
17.2
208
20
18.7
195
7
20.2
192
4
20.2
187
0
20.8

50TJ016 (15 Tons) (cont)

50TJ

Temp (F)
Air Entering
Condenser
(Edb)
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW

75

85

95

105

115

117

120

BF
Edb
Ewb
kW
ldb
lwb
SHC
TC

Evaporator Air Quantity Cfm


6000
54/0.53
164
164
12.6
157
157
14.1
148
148
15.2
139
139
16.6
129
129
18.0
127
127
18.3
123
123
18.6

58/0.42
170
146
12.7
161
139
14.0
152
129
15.3
143
121
16.7
133
111
18.2
131
107
18.5
127
104
18.8

62/0.30
175
140
12.9
168
132
14.2
157
123
15.5
147
114
16.9
137
105
18.3
135
103
18.6
131
99
18.9

67/0.28
191
118
13.2
182
109
14.6
172
100
15.9
161
90
17.3
150
80
18.8
148
78
19.1
144
75
19.4

6750
72/0.27
209
94
13.6
199
85
15.0
188
75
16.4
177
65
17.8
165
54
19.3
163
52
19.6
159
48
20.0

LEGEND
Bypass Factor
Entering Dry-Bulb
Entering Wet-Bulb
Compressor Motor Power Input
Leaving Dry-Bulb
Leaving Wet-Bulb
Sensible Heat Capacity (1000 Btuh) Gross
Total Capacity (1000 Btuh) Gross

NOTES:
1. Direct interpolation is permissible. Do not extrapolate.
2. The following formulas may be used:
sensible capacity (Btuh)
1.10 x cfm

tldb =

tedb

tlwb =

Wet-bulb temperature corresponding to enthalpy of air


leaving evaporator coil (hlwb)

total capacity (Btuh)


4.5 x cfm
Where: hewb = Enthalpy of air entering evaporator coil

hlwb = hewb

108

Evaporator Air Ewb (F)/BF


76/0.30 80/0.03 54/0.57 58/0.48
225
241
169
176
73
52
169
148
14.0
14.3
12.4
12.9
215
231
162
167
63
42
162
140
15.6
16.0
14.0
14.2
203
218
154
159
53
31
154
132
16.7
17.1
15.3
15.5
191
206
144
148
43
20
144
122
18.2
18.6
16.8
16.9
179
193
134
138
31
8
134
112
19.8
20.4
18.2
18.3
176
189
132
136
29
6
132
109
20.0
20.4
18.5
18.6
179
193
128
132
31
8
128
105
19.8
20.4
18.8
18.9

62/0.33
179
148
12.9
170
139
14.2
160
131
15.6
150
122
17.0
140
112
18.4
138
109
18.7
134
106
19.0

67/0.31
195
124
13.3
185
115
14.6
175
106
16.0
164
96
17.4
153
85
18.9
151
83
19.2
146
79
19.5

3. The SHC is based on 80 F edb temperature of air entering evaporator coil.


Below 80 F edb, subtract (corr factor x cfm) from SHC.
Above 80 F edb, add (corr factor x cfm) to SHC.
BYPASS
FACTOR
(BF)

79
81

0.05
0.10
0.20
0.30
0.40
0.50
0.60
0.70

1.04
0.98
0.87
0.76
0.65
0.55
0.44
0.33

ENTERING AIR DRY-BULB TEMP (F)


78
77
76
75
under 75
82
83
84
85
over 85
Correction Factor
2.07
3.11
4.14
5.18
1.96
2.94
3.92
4.91
1.74
2.62
3.49
4.36
1.53
2.29
3.05
3.82
Use formula
shown below.
1.31
1.96
2.62
3.27
1.09
0.87
0.65

1.64
1.31
0.98

2.18
1.74
1.31

Interpolation is permissible.
Correction Factor = 1.10 x (1 BF) x (edb 80).

2.73
2.18
1.64

COOLING CAPACITIES UNITS WITH MOISTUREMI$ER OPTION (cont)


50TJ016 (15 Tons) (cont)
Temp (F)
Air Entering
Condenser
(Edb)
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW

75

85

95

105

115

117

120

BF
Edb
Ewb
kW
ldb
lwb
SHC
TC

54/0.6
176
176
12.9
167
167
14.2
158
158
15.5
148
148
16.9
138
138
18.4
135
135
18.6
132
132
18.9

Evaporator Air Quantity Cfm


7500
Evaporator Air Ewb (F)/BF
58/0.52 62/0.36 67/0.33 72/0.31 76/0.33
182
182
197
215
231
151
153
129
101
78
13.0
13.0
13.4
13.8
14.1
173
173
187
206
221
143
145
120
92
67
14.5
14.3
14.7
15.3
15.8
163
164
177
194
208
135
136
110
82
57
15.6
15.7
16.1
16.5
16.9
152
153
166
182
196
129
127
100
71
46
17.0
17.1
17.5
18.0
18.4
140
143
155
170
183
122
116
90
60
34
18.5
18.5
19.0
19.5
19.9
138
140
152
167
180
120
113
87
57
31
18.7
18.8
19.2
19.7
20.1
134
137
148
163
176
117
110
84
53
27
19.1
19.1
19.6
20.1
20.5

LEGEND
Bypass Factor
Entering Dry-Bulb
Entering Wet-Bulb
Compressor Motor Power Input
Leaving Dry-Bulb
Leaving Wet-Bulb
Sensible Heat Capacity (1000 Btuh) Gross
Total Capacity (1000 Btuh) Gross

sensible capacity (Btuh)


1.10 x cfm

tldb =

tedb

tlwb =

Wet-bulb temperature corresponding to enthalpy of air


leaving evaporator coil (hlwb)

total capacity (Btuh)


4.5 x cfm
Where: hewb = Enthalpy of air entering evaporator coil

hlwb = hewb

3. The SHC is based on 80 F edb temperature of air entering evaporator coil.


Below 80 F edb, subtract (corr factor x cfm) from SHC.
Above 80 F edb, add (corr factor x cfm) to SHC.
BYPASS
FACTOR
(BF)

79
81

0.05
0.10
0.20
0.30
0.40
0.50
0.60
0.70

1.04
0.98
0.87
0.76
0.65
0.55
0.44
0.33

ENTERING AIR DRY-BULB TEMP (F)


78
77
76
75
under 75
82
83
84
85
over 85
Correction Factor
2.07
3.11
4.14
5.18
1.96
2.94
3.92
4.91
1.74
2.62
3.49
4.36
1.53
2.29
3.05
3.82
Use formula
shown below.
1.31
1.96
2.62
3.27
1.09
1.64
2.18
2.73
0.87
1.31
1.74
2.18
0.65
0.98
1.31
1.64

Interpolation is permissible.
Correction Factor = 1.10 x (1 BF) x (edb 80).

109

50TJ

NOTES:
1. Direct interpolation is permissible. Do not extrapolate.
2. The following formulas may be used:

80/0.03
247
52
14.5
237
42
16.2
224
31
17.3
211
19
18.7
196
6
20.2
194
3
20.4
188
0
20.8

Performance data 50TJ (cont)


COOLING CAPACITIES UNITS WITH MOISTUREMI$ER OPTION (cont)
50TJ020 (18 Tons)
Temp (F)
Air Entering
Condenser
(Edb)
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW

75

85

95

105

115

117

120

Evaporator Air Quantity Cfm


4500
54/0.42
180
180
13.3
171
171
14.7
162
162
16.1
152
152
17.5
140
140
19.0
138
138
19.3
133
133
19.7

58/0.27
185
165
13.5
176
156
14.9
167
147
16.3
157
138
17.7
147
127
19.0
143
123
19.5
139
119
19.9

62/0.20
193
151
14.1
187
143
15.2
178
134
16.6
167
125
18.1
155
113
19.5
152
111
19.8
148
107
20.2

67/0.18
214
129
14.3
205
120
15.7
195
110
17.1
183
100
18.6
170
88
20.1
167
85
20.4
163
81
20.8

5250
72/0.17
235
104
14.8
225
94
16.2
213
84
17.7
201
73
19.1
187
60
20.7
184
57
21.0
179
53
21.5

Evaporator Air Ewb (F)/BF


76/0.26 80/0.05 54/0.46 58/0.33
253
272
187
193
82
62
187
170
15.2
15.6
13.5
13.7
243
260
178
184
72
51
178
161
16.9
17.3
14.9
15.1
230
247
168
174
61
40
168
152
18.1
18.5
16.3
16.5
219
233
158
164
50
27
158
141
19.9
20.0
17.7
17.9
202
216
145
152
36
13
145
129
21.2
21.7
19.2
19.3
199
214
143
149
33
10
143
126
21.5
22.0
19.5
19.7
194
209
139
145
29
6
139
122
22.0
22.5
20.0
20.1

62/0.21
198
159
14.2
191
152
15.3
182
143
16.7
171
132
18.2
158
121
19.7
155
118
19.9
151
114
20.4

67/0.19
219
135
14.4
209
126
15.8
198
116
17.2
187
106
18.9
173
93
20.2
170
90
20.5
166
86
21.0

72/0.18
239
108
14.9
229
99
16.3
217
88
17.8
205
77
19.2
190
63
20.8
187
60
21.1
182
56
21.6

76/0.22
257
85
15.3
246
75
16.8
234
64
18.3
221
52
19.8
206
39
21.5
201
35
21.6
196
30
22.1

80/0.05
276
62
15.7
265
52
17.5
251
39
18.6
236
26
20.1
219
11
21.8
217
9
22.1
211
4
22.6

72/0.22
250
122
15.2
238
111
16.6
226
100
18.1
214
88
19.6
197
73
21.1
194
70
21.4
189
66
21.9

76/0.23
267
93
15.6
256
82
17.3
243
70
18.5
230
58
20.3
212
42
21.6
209
39
21.9
204
35
22.4

80/0.04

50TJ020 (18 Tons) (cont)

50TJ

Temp (F)
Air Entering
Condenser
(Edb)
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW

75

85

95

105

115

117

120

BF
Edb
Ewb
kW
ldb
lwb
SHC
TC

Evaporator Air Quantity Cfm


6000
54/0.52
197
197
13.8
188
188
15.2
177
177
16.6
166
166
18.0
153
153
19.5
150
150
19.7
145
145
20.2

58/0.37
201
183
13.9
191
175
15.3
180
167
16.7
169
159
18.1
156
146
19.6
152
144
19.8
147
140
20.3

62/0.24
207
173
14.1
197
164
15.5
188
155
16.9
176
144
18.3
162
131
19.8
159
128
20.1
155
124
20.5

67/0.21
225
146
14.6
215
136
16.0
203
126
17.4
192
115
18.9
177
102
20.4
174
99
20.7
170
94
21.2

6750
72/0.20
245
115
15.0
234
105
16.5
223
94
18.0
210
82
19.4
195
69
21.2
191
65
21.3
186
61
21.8

LEGEND
Bypass Factor
Entering Dry-Bulb
Entering Wet-Bulb
Compressor Motor Power Input
Leaving Dry-Bulb
Leaving Wet-Bulb
Sensible Heat Capacity (1000 Btuh) Gross
Total Capacity (1000 Btuh) Gross

NOTES:
1. Direct interpolation is permissible. Do not extrapolate.
2. The following formulas may be used:
sensible capacity (Btuh)
1.10 x cfm

tldb =

tedb

tlwb =

Wet-bulb temperature corresponding to enthalpy of air


leaving evaporator coil (hlwb)

total capacity (Btuh)


4.5 x cfm
Where: hewb = Enthalpy of air entering evaporator coil

hlwb = hewb

110

Evaporator Air Ewb (F)/BF


76/0.21 80/0.05 54/0.56 58/0.40
262
282
205
205
89
63
205
205
15.5
15.9
14.0
14.1
252
270
196
196
79
51
196
196
17.2
17.5
15.5
15.5
238
256
185
185
67
39
185
185
18.4
18.9
16.8
16.8
225

173
174
55

173
174
20.0

18.2
18.2
209

160
160
40

160
160
21.4

19.7
19.7
206

157
157
37

157
157
21.8

20.0
20.0
209

152
152
40

152
152
21.4

20.5
20.5

62/0.28
212
184
14.2
202
175
15.7
191
164
17.0
180
153
18.4
166
139
19.9
163
137
20.3
158
132
20.6

67/0.23
229
155
14.7
219
145
16.1
207
135
17.5
195
124
19.0
181
110
20.4
177
107
20.8
173
102
21.3

3. The SHC is based on 80 F edb temperature of air entering evaporator coil.


Below 80 F edb, subtract (corr factor x cfm) from SHC.
Above 80 F edb, add (corr factor x cfm) to SHC.
BYPASS
FACTOR
(BF)

79
81

0.05
0.10
0.20
0.30
0.40
0.50
0.60
0.70

1.04
0.98
0.87
0.76
0.65
0.55
0.44
0.33

ENTERING AIR DRY-BULB TEMP (F)


78
77
76
75
under 75
82
83
84
85
over 85
Correction Factor
2.07
3.11
4.14
5.18
1.96
2.94
3.92
4.91
1.74
2.62
3.49
4.36
1.53
2.29
3.05
3.82
Use formula
shown below.
1.31
1.96
2.62
3.27
1.09
0.87
0.65

1.64
1.31
0.98

2.18
1.74
1.31

Interpolation is permissible.
Correction Factor = 1.10 x (1 BF) x (edb 80).

2.73
2.18
1.64

COOLING CAPACITIES UNITS WITH MOISTUREMI$ER OPTION (cont)


50TJ020 (18 Tons) (cont)
Temp (F)
Air Entering
Condenser
(Edb)
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW

75

85

95

105

115

117

120

BF
Edb
Ewb
kW
ldb
lwb
SHC
TC

54/0.6
212
212
14.1
203
203
15.6
191
191
17.0
179
179
18.4
165
165
19.9
162
162
20.2
157
157
20.7

Evaporator Air Quantity Cfm


7500
Evaporator Air Ewb (F)/BF
58/0.46 62/0.33 67/0.25 72/0.23 76/0.23
212
218
233
253
271
212
192
165
128
97
14.3
14.4
14.8
15.3
15.7
203
207
222
242
260
203
182
155
117
86
15.7
15.8
16.2
16.7
17.4
192
197
211
229
246
192
171
144
106
73
17.0
17.2
17.7
18.2
18.7
179
185
198
217
233
179
159
132
93
61
18.4
18.6
19.1
19.7
20.2
165
170
184
200
215
165
144
118
78
45
19.9
20.1
20.5
21.2
21.7
162
167
179
196
212
162
141
115
75
41
20.2
20.4
20.9
21.5
22.0
157
162
175
192
206
157
137
110
70
37
20.6
20.9
21.3
21.9
22.5

LEGEND
Bypass Factor
Entering Dry-Bulb
Entering Wet-Bulb
Compressor Motor Power Input
Leaving Dry-Bulb
Leaving Wet-Bulb
Sensible Heat Capacity (1000 Btuh) Gross
Total Capacity (1000 Btuh) Gross

sensible capacity (Btuh)


1.10 x cfm

tldb =

tedb

tlwb =

Wet-bulb temperature corresponding to enthalpy of air


leaving evaporator coil (hlwb)

total capacity (Btuh)


4.5 x cfm
Where: hewb = Enthalpy of air entering evaporator coil

hlwb = hewb

3. The SHC is based on 80 F edb temperature of air entering evaporator coil.


Below 80 F edb, subtract (corr factor x cfm) from SHC.
Above 80 F edb, add (corr factor x cfm) to SHC.
BYPASS
FACTOR
(BF)

79
81

0.05
0.10
0.20
0.30
0.40
0.50
0.60
0.70

1.04
0.98
0.87
0.76
0.65
0.55
0.44
0.33

ENTERING AIR DRY-BULB TEMP (F)


78
77
76
75
under 75
82
83
84
85
over 85
Correction Factor
2.07
3.11
4.14
5.18
1.96
2.94
3.92
4.91
1.74
2.62
3.49
4.36
1.53
2.29
3.05
3.82
Use formula
shown below.
1.31
1.96
2.62
3.27
1.09
0.87
0.65

1.64
1.31
0.98

2.18
1.74
1.31

2.73
2.18
1.64

Interpolation is permissible.
Correction Factor = 1.10 x (1 BF) x (edb 80).

111

50TJ

NOTES:
1. Direct interpolation is permissible. Do not extrapolate.
2. The following formulas may be used:

80/0.05

Performance data 50TJ (cont)


COOLING CAPACITIES UNITS WITH MOISTUREMI$ER OPTION (cont)
50TJ024 (20 Tons)
Temp (F)
Air Entering
Condenser
(Edb)
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW

75

85

95

105

115

117

120

Evaporator Air Quantity Cfm


4500
54/0.41

58.0.27

200
176
16.7
190
168
18.4
180
157
20.3
169
146
22.2
167
144
22.6
163
141
23.2

62/0.20
222
171
15.3
212
162
17.0
202
152
18.7
191
142
20.5
179
132
22.6
177
130
23.0
173
126
23.6

67/0.19
243
146
15.8
233
136
17.7
221
126
19.2
209
115
21.1
197
104
23.1
195
102
23.5
191
99
24.1

5250
72/0.18
262
118
16.3
255
109
18.0
244
98
19.8
231
87
21.6
218
75
23.7
215
73
24.1
211
69
24.7

Evaporator Air Ewb (F)/BF


76/0.25 80/0.05 54/0.47 58/0.35
288
310
215
222
96
75
215
192
16.7
17.2
15.2
15.3
276
298
206
211
85
63
206
185
18.4
19.1
17.0
17.0
263
283
195
201
74
51
195
174
20.3
20.7
18.5
18.7
250
270
184
191
62
39
184
163
22.1
22.7
20.3
20.5
236
255
173
179
50
27
173
152
24.2
24.7
22.3
22.6
233
252
171
177
48
24
171
149
24.6
25.1
22.7
23.0
229

167
173
44

167
146
25.2

23.3
23.6

62/0.22
226
184
15.7
219
175
17.1
208
165
18.9
198
155
20.6
185
144
22.8
183
142
23.2
179
138
23.7

67/0.21
250
157
16.0
239
146
17.8
228
136
19.5
217
126
21.0
203
113
23.3
200
111
23.7
196
108
24.3

72/0.20
274
126
16.5
263
116
18.5
249
104
19.9
236
93
21.8
224
81
23.8
220
78
24.3
216
75
24.9

76/0.25
295
100
16.9
282
89
18.6
270
77
20.5
255
65
22.3
241
53
24.4
238
50
24.8
234
46
25.4

80/0.04
318
76
17.4
305
64
19.3
290
52
20.9
276
39
22.9
261
26
24.8
258
23
25.3

72/0.23
284
140
16.7
272
128
18.7
259
117
20.2
245
104
22.1
231
92
24.1
228
89
24.5
224
85
25.1

76/0.24
305
109
17.2
292
97
19.1
279
85
20.8
264
72
22.5
249
58
24.6
246
56
25.0
242
51
25.6

80/0.04

50TJ024 (20 Tons) (cont)

50TJ

Temp (F)
Air Entering
Condenser
(Edb)
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW

75

85

95

105

115

117

120

BF
Edb
Ewb
kW
ldb
lwb
SHC
TC

Evaporator Air Quantity Cfm


6000
54/0.52
224
224
15.4
215
215
17.1
204
204
18.8
193
193
20.6
181
181
22.6
179
179
23.0
175
175
23.6

58/0.38
227
212
15.4
218
202
17.1
207
191
18.9
197
181
20.5
185
169
22.7
182
166
23.1
178
162
23.7

62/0.25
232
196
15.8
224
187
17.3
213
177
19.0
203
166
20.8
190
155
22.8
187
153
23.3
184
149
23.9

67/0.23
256
167
16.1
244
156
17.8
232
145
19.5
221
134
21.4
207
122
23.4
205
120
23.8
201
116
24.5

6750
72/0.21
280
133
16.6
268
122
18.6
254
111
20.1
242
99
21.9
228
86
24.0
225
84
24.4
221
80
25.0

LEGEND
Bypass Factor
Entering Dry-Bulb
Entering Wet-Bulb
Compressor Motor Power Input
Leaving Dry-Bulb
Leaving Wet-Bulb
Sensible Heat Capacity (1000 Btuh) Gross
Total Capacity (1000 Btuh) Gross

NOTES:
1. Direct interpolation is permissible. Do not extrapolate.
2. The following formulas may be used:
sensible capacity (Btuh)
1.10 x cfm

tldb =

tedb

tlwb =

Wet-bulb temperature corresponding to enthalpy of air


leaving evaporator coil (hlwb)

total capacity (Btuh)


4.5 x cfm
Where: hewb = Enthalpy of air entering evaporator coil

hlwb = hewb

112

Evaporator Air Ewb (F)/BF


76/0.24 80/0.04 54/0.56 58/0.42
301
319
231
236
105
76
231
222
17.0
17.2
15.4
15.7
288
310
222
225
93
64
222
213
19.0
19.5
17.2
17.3
274
296
211
213
81
52
211
204
20.5
21.2
19.0
19.0
260
282
200
202
69
39
200
195
22.4
23.1
20.8
20.8
247
265
188
189
56
25
188
185
24.4
25.0
22.8
22.8
243
262
185
186
53
22
185
182
24.9
25.4
23.2
23.2
247

181
183
56

181
177
24.4

23.8
23.8

62/0.28
241
209
15.9
231
198
17.5
219
187
19.2
207
177
20.9
194
164
23.0
192
162
23.4
188
158
24.0

67/0.24
261
177
16.2
250
166
18.1
237
155
19.6
224
143
21.5
211
131
23.5
208
129
23.9
204
125
24.6

3. The SHC is based on 80 F edb temperature of air entering evaporator coil.


Below 80 F edb, subtract (corr factor x cfm) from SHC.
Above 80 F edb, add (corr factor x cfm) to SHC.
BYPASS
FACTOR
(BF)

79
81

0.05
0.10
0.20
0.30
0.40
0.50
0.60
0.70

1.04
0.98
0.87
0.76
0.65
0.55
0.44
0.33

ENTERING AIR DRY-BULB TEMP (F)


78
77
76
75
under 75
82
83
84
85
over 85
Correction Factor
2.07
3.11
4.14
5.18
1.96
2.94
3.92
4.91
1.74
2.62
3.49
4.36
1.53
2.29
3.05
3.82
Use formula
shown below.
1.31
1.96
2.62
3.27
1.09
0.87
0.65

1.64
1.31
0.98

2.18
1.74
1.31

Interpolation is permissible.
Correction Factor = 1.10 x (1 BF) x (edb 80).

2.73
2.18
1.64

COOLING CAPACITIES UNITS WITH MOISTUREMI$ER OPTION (cont)


50TJ024 (20 Tons) (cont)
Temp (F)
Air Entering
Condenser
(Edb)
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW

75

85

95

105

115

117

120

BF
Edb
Ewb
kW
ldb
lwb
SHC
TC

54/0.6
238
238
15.5
229
229
17.4
217
217
19.1
206
206
21.0
194
194
23.0
191
191
23.4
187
187
24.0

Evaporator Air Quantity Cfm


7500
Evaporator Air Ewb (F)/BF
58/0.45 62/0.32 67/0.26 72/0.24 76/0.25
240
247
264
288
309
240
216
186
146
112
15.8
15.9
16.3
16.8
17.3
229
235
253
276
297
229
206
175
135
101
17.4
17.6
18.1
18.5
19.4
218
225
240
262
282
218
194
164
123
88
19.2
19.4
19.7
20.3
20.9
206
212
228
249
268
206
183
152
110
75
21.0
21.1
21.7
22.1
22.8
194
199
214
234
253
194
170
139
97
61
23.0
23.2
23.6
24.2
24.6
191
197
211
231
249
191
168
137
94
58
23.4
23.6
24.0
24.6
25.1
187
192
207
227

187
164
133
90

24.0
24.2
24.7
25.2

LEGEND
Bypass Factor
Entering Dry-Bulb
Entering Wet-Bulb
Compressor Motor Power Input
Leaving Dry-Bulb
Leaving Wet-Bulb
Sensible Heat Capacity (1000 Btuh) Gross
Total Capacity (1000 Btuh) Gross

sensible capacity (Btuh)


1.10 x cfm

tldb =

tedb

tlwb =

Wet-bulb temperature corresponding to enthalpy of air


leaving evaporator coil (hlwb)

total capacity (Btuh)


4.5 x cfm
Where: hewb = Enthalpy of air entering evaporator coil

hlwb = hewb

3. The SHC is based on 80 F edb temperature of air entering evaporator coil.


Below 80 F edb, subtract (corr factor x cfm) from SHC.
Above 80 F edb, add (corr factor x cfm) to SHC.
BYPASS
FACTOR
(BF)

79
81

0.05
0.10
0.20
0.30
0.40
0.50
0.60
0.70

1.04
0.98
0.87
0.76
0.65
0.55
0.44
0.33

ENTERING AIR DRY-BULB TEMP (F)


78
77
76
75
under 75
82
83
84
85
over 85
Correction Factor
2.07
3.11
4.14
5.18
1.96
2.94
3.92
4.91
1.74
2.62
3.49
4.36
1.53
2.29
3.05
3.82
Use formula
shown below.
1.31
1.96
2.62
3.27
1.09
0.87
0.65

1.64
1.31
0.98

2.18
1.74
1.31

2.73
2.18
1.64

Interpolation is permissible.
Correction Factor = 1.10 x (1 BF) x (edb 80).

113

50TJ

NOTES:
1. Direct interpolation is permissible. Do not extrapolate.
2. The following formulas may be used:

80/0.04

Performance data 50TJ (cont)


COOLING CAPACITIES UNITS WITH MOISTUREMI$ER OPTION (cont)
50TJ028 (25 Tons)
Temp (F)
Air Entering
Condenser
(Edb)
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW

75

85

95

105

115

117

120

Evaporator Air Quantity Cfm


7,000
54/0.39

58/0.22

62/0.13
219
169
18.2
201
153
19.9
186
140
21.7
171
126
23.6
154
111
25.7
152
108
26.1
147
105
27.0

67/0.12
245
139
18.8
225
122
20.5
209
107
22.3
192
92
24.3
176
78
26.4
172
75
26.8
168
70
27.6

8,000
72/0.13
276
108
19.5
254
90
21.2
234
73
23.0
216
57
25.0
199
42
27.1
195
39
27.6
190
34
28.3

Evaporator Air Ewb (F)/BF


76/0.23 80/0.01 54/0.44 58/0.28
303
328

82
58

20.1
20.6

280
305

195
62
39

178
21.8
22.4

19.7
257
280
176
181
44
19
176
165
23.7
24.3
21.4
21.5
238
259
164
166
28
1
164
151
25.8
26.3
23.4
23.4
219
239
147
150
11
16
147
135
27.8
28.4
25.5
25.5
215
235
144
148
8
19
144
130
28.3
28.9
25.9
26.0
210
229
139
143
3
24
139
127
29.0
29.6
26.6
26.7

62/0.15
225
184
18.4
206
167
20.0
190
152
21.8
174
138
23.8
158
123
25.8
155
120
26.3
149
115
27.0

67/0.14
252
151
19.0
230
132
20.6
214
116
22.5
197
101
24.6
179
86
26.5
176
83
27.0
171
78
27.7

72/0.13
282
115
19.6
259
96
21.3
239
79
23.2
220
62
25.1
202
46
27.3
198
43
27.7
193
38
28.4

76/0.20
309
85
20.2
285
66
22.0
261
46
23.8
242
29
25.8
222
13
27.9
218
9
28.4
212
4
29.1

80/0.00
335
58
20.8
311
39
22.6
285
18
24.5
264
1
26.4
243
19
28.6
238
22
29.0
232
28
29.7

72/0.16
292
129
19.9
268
109
21.6
246
89
23.4
227
72
25.4
207
54
27.5
203
51
27.9
197
46
28.6

76/0.18
319
94
20.5
294
73
22.2
269
51
24.0
248
33
26.0
227
15
28.1
223
11
28.6
217
6
29.3

80/0.00
346
59
21.1
320
38
22.8
293
15
24.7
270
5
26.7
248
24
28.8
244
28
29.2
237
34
29.9

50TJ028 (25 Tons) (cont)

50TJ

Temp (F)
Air Entering
Condenser
(Edb)
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW

75

85

95

105

115

117

120

BF
Edb
Ewb
kW
ldb
lwb
SHC
TC

Evaporator Air Quantity Cfm


9,000
54/0.48
217
217
18.2
200
200
20.2
184
184
21.7
169
169
23.6
152
152
25.7
150
150
26.2
144
144
26.9

58/0.33
222
203
18.3
204
185
20.0
188
168
21.9
172
155
23.7
155
140
25.8
152
140
26.2
147
134
26.9

62/0.16
229
198
18.5
211
181
20.1
194
165
22.0
177
150
23.9
160
135
26.0
157
131
26.4
151
126
27.1

67/0.15
257
162
19.1
234
141
20.8
217
126
22.6
200
110
24.7
182
94
26.6
178
91
27.1
173
86
27.8

10,000
72/0.15
287
122
19.7
264
103
21.4
243
84
23.3
224
67
25.3
205
50
27.5
202
47
27.8
195
42
28.5

LEGEND
Bypass Factor
Entering Dry-Bulb
Entering Wet-Bulb
Compressor Motor Power Input
Leaving Dry-Bulb
Leaving Wet-Bulb
Sensible Heat Capacity (1000 Btuh) Gross
Total Capacity (1000 Btuh) Gross

NOTES:
1. Direct interpolation is permissible. Do not extrapolate.
2. The following formulas may be used:
sensible capacity (Btuh)
1.10 x cfm

tldb =

tedb

tlwb =

Wet-bulb temperature corresponding to enthalpy of air


leaving evaporator coil (hlwb)

total capacity (Btuh)


4.5 x cfm
Where: hewb = Enthalpy of air entering evaporator coil

hlwb = hewb

114

Evaporator Air Ewb (F)/BF


76/0.18 80/0.00 54/0.52 58/0.36
314
341
226
228
90
58
226
219
20.3
20.9
18.4
18.5
290
316
207
209
70
38
207
200
22.1
22.7
20.1
20.6
266
290
191
193
49
17
191
184
23.9
24.6
21.9
21.9
245
267
175
176
31
3
175
168
25.9
26.6
24.0
23.9
225
246
157
160
14
22
157
153
28.0
28.7
25.9
26.0
222
241
154
155
11
25
154
150
28.5
29.1
26.4
26.4
225
235
148
149
14
31
148
143
28.0
29.8
27.0
27.1

62/0.18
234
212
18.6
214
193
20.3
197
177
22.1
180
161
24.0
162
145
26.1
159
141
26.5
153
136
27.2

67/0.16
262
172
19.2
239
152
20.9
220
134
22.7
202
118
24.8
184
102
26.7
180
99
27.2
175
94
27.9

3. The SHC is based on 80 F edb temperature of air entering evaporator coil.


Below 80 F edb, subtract (corr factor x cfm) from SHC.
Above 80 F edb, add (corr factor x cfm) to SHC.
BYPASS
FACTOR
(BF)

79
81

0.05
0.10
0.20
0.30
0.40
0.50
0.60
0.70

1.04
0.98
0.87
0.76
0.65
0.55
0.44
0.33

ENTERING AIR DRY-BULB TEMP (F)


78
77
76
75
under 75
82
83
84
85
over 85
Correction Factor
2.07
3.11
4.14
5.18
1.96
2.94
3.92
4.91
1.74
2.62
3.49
4.36
1.53
2.29
3.05
3.82
Use formula
shown below.
1.31
1.96
2.62
3.27
1.09
0.87
0.65

1.64
1.31
0.98

2.18
1.74
1.31

Interpolation is permissible.
Correction Factor = 1.10 x (1 BF) x (edb 80).

2.73
2.18
1.64

COOLING CAPACITIES UNITS WITH MOISTUREMI$ER OPTION (cont)


50TJ028 (25 Tons) (cont)
Temp (F)
Air Entering
Condenser
(Edb)
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW

75

85

95

105

115

117

120

BF
Edb
Ewb
kW
ldb
lwb
SHC
TC

54/0.56
235
235
18.7
215
215
20.3
197
197
22.1
180
180
24.1
162
162
26.1
159
159
26.6
152
152
27.3

Evaporator Air Quantity Cfm


11,250
Evaporator Air Ewb (F)/BF
58/0.41 62/0.22 67/0.18 72/0.17 76/0.18
234
239
266
296
323
234
225
185
137
98
18.6
18.7
19.3
20.0
20.5
214
218
242
271
298
214
205
163
116
77
20.3
20.4
21.0
21.7
22.3
198
201
223
249
272
198
188
146
96
55
22.1
22.2
22.8
23.5
24.1
180
184
205
229
251
180
172
129
78
36
24.1
24.3
24.8
25.5
26.2
162
165
186
209
230
162
153
112
60
17
26.1
26.2
26.8
27.6
28.2
158
161
182
205
226
158
149
109
57
13
26.6
26.6
27.3
28.0
28.7
152
155
176
199
219
152
143
103
51
7
27.3
27.3
28.0
28.7
29.4

LEGEND
Bypass Factor
Entering Dry-Bulb
Entering Wet-Bulb
Compressor Motor Power Input
Leaving Dry-Bulb
Leaving Wet-Bulb
Sensible Heat Capacity (1000 Btuh) Gross
Total Capacity (1000 Btuh) Gross

sensible capacity (Btuh)


1.10 x cfm

tldb =

tedb

tlwb =

Wet-bulb temperature corresponding to enthalpy of air


leaving evaporator coil (hlwb)

total capacity (Btuh)


4.5 x cfm
Where: hewb = Enthalpy of air entering evaporator coil

hlwb = hewb

3. The SHC is based on 80 F edb temperature of air entering evaporator coil.


Below 80 F edb, subtract (corr factor x cfm) from SHC.
Above 80 F edb, add (corr factor x cfm) to SHC.
BYPASS
FACTOR
(BF)

79
81

0.05
0.10
0.20
0.30
0.40
0.50
0.60
0.70

1.04
0.98
0.87
0.76
0.65
0.55
0.44
0.33

ENTERING AIR DRY-BULB TEMP (F)


78
77
76
75
under 75
82
83
84
85
over 85
Correction Factor
2.07
3.11
4.14
5.18
1.96
2.94
3.92
4.91
1.74
2.62
3.49
4.36
1.53
2.29
3.05
3.82
Use formula
shown below.
1.31
1.96
2.62
3.27
1.09
0.87
0.65

1.64
1.31
0.98

2.18
1.74
1.31

2.73
2.18
1.64

Interpolation is permissible.
Correction Factor = 1.10 x (1 BF) x (edb 80).

115

50TJ

NOTES:
1. Direct interpolation is permissible. Do not extrapolate.
2. The following formulas may be used:

80/0.00
351
59
21.2
324
37
22.9
297
14
24.8
273
7
26.8

Performance data 50TJ (cont)


GLYCOL HEATING PERFORMANCE
GLYCOL COIL (50TJ016-028)

Edb
55

70

80

Air Entering Cfm


5400
Percent Glycol

4400

Temperature
Entering
Ewt
200
180
160
200
180
160
200
180
160

Cap
310
255
200
274
218
164
249
194
140

25
Gpm
33
27
21
29
23
17
26
21
15

Ldb
120
108
97
127
116
104
132
121
109

50
Gpm
33
27
21
29
23
17
27
20
14

Cap
293
237
181
257
201
146
233
177
123

Ldb
116
105
93
124
112
100
129
117
106

Cap
347
285
223
306
244
183
279
217
156

25
Gpm
37
30
24
32
26
19
30
23
16

Edb

Air Entering Cfm


9000
Percent Glycol

55

70

Cap
453
371
290
400
317
237
364
281
201

25
Gpm
48
39
31
42
34
25
39
30
21

50
Gpm
37
30
23
33
26
19
30
23
16

Ldb
111
101
90
119
109
98
125
114
103

Cap
405
332
259
357
284
212
325
252
180

25
Gpm
43
35
27
38
30
22
34
26
18

Ldb
107
98
89
116
107
97
122
113
103

Cap
381
306
233
333
259
187
302
228
156

50
Gpm
43
35
27
38
30
22
34
27
19

Ldb
104
95
85
113
104
94
119
109
100

Ldb
102
93
85
111
103
94
118
109
101

Cap
425
342
260
372
287
208
337
254
173

Entering
Fluid
Temp (F)
50
Gpm
48
39
30
42
33
24
38
29
20

4,000
Gpm
P*
27
1.2
22
0.9
16
0.6

200
180
160

Ldb
99
90
82
108
100
91
115
106
78

5,000
Gpm
P*
31
1.5
25
1.1
19
0.7

Cfm
6,000
Gpm
P*
35
1.8
27
1.3
20
0.8

8,000
Gpm
P*
41
2.4
32
1.6
24
1.0

10,000
Gpm
P*
47
2.9
36
2.0
27
1.2

LEGEND
Cap
Edb
Ewt
Gpm
Ldb

Btuh 1000
Entering Dry Bulb Temperature (F)
Entering Water Temperature (F)
Gallons Per Minute
Leaving Dry-Bulb Temperature (F)

*P is the fluid pressure in ft of head.


NOTES:
1. This accessory glycol coil is intended for use with a MINIMUM of 25% glycol solution. It
IS NOT intended for use solely with water due to freeze-up conditions and the resulting
water damage to the conditioned space.
2. Water = 20 F.

50TJ

80

Ewt
200
180
160
200
180
160
200
180
160

Cap
327
264
202
287
224
162
260
197
136

GLYCOL COIL RATINGS (50TJ016-028)

GLYCOL COIL (50TJ016-028) (cont)


Temperature
Entering

Ldb
115
104
94
123
112
101
128
117
107

7200

FAN PERFORMANCE 50TJ016-028 UNITS


LEGEND

50TJ016 (15 TONS)*


Airflow
(Cfm)
4500
4800
5100
5400
5700
6000
6300
6600
6900
7200
7500

Rpm
684
715
747
779
812
845
878
912
946
981
1016

0.2
Bhp
1.28
1.47
1.67
1.90
2.14
2.40
2.68
2.98
3.29
3.63
3.99

Watts
1102
1265
1442
1635
1844
2068
2309
2566
2841
3133
3443

Available External Static Pressure (in. wg)


0.6
0.8
Watts Rpm Bhp Watts Rpm Bhp Watts
1283
887 1.70 1466
977 1.92 1652
1451
910 1.90 1638
997 2.12 1828
1633
934 2.12 1825 1018 2.34 2019
1831
959 2.35 2027 1040 2.58 2226
2044
985 2.60 2245 1063 2.84 2448
2273 1011 2.87 2478 1087 3.11 2685
2518 1039 3.16 2728 1112 3.41 2939
2780 1067 3.47 2994 1138 3.72 3209
3059 1096 3.80 3277 1165 4.05 3496
3355 1125 4.15 3578

3669

Rpm
791
817
844
872
901
931
961
992
1023
1055
1087

0.4
Bhp
1.49
1.68
1.89
2.12
2.37
2.64
2.92
3.22
3.55
3.89
4.25

Rpm
1285
1297
1311
1326
1342
1359

Available External Static Pressure (in. wg)


1.6
1.8
1.9
Bhp Watts Rpm Bhp Watts Rpm Bhp
2.82 2430 1353 3.05 2633 1386 3.17
3.04 2619 1364 3.27 2825 1396 3.40
3.27 2823 1376 3.51 3031 1408 3.64
3.53 3043 1390 3.77 3254 1421 3.90
3.80 3278 1405 4.05 3492 1435 4.17
4.09 3530 1421 4.34 3746

Rpm
1061
1078
1097
1117
1138
1160
1183
1207
1232

1.0
Bhp
2.13
2.34
2.57
2.81
3.07
3.35
3.65
3.97
4.31

Watts
1841
2021
2216
2426
2652
2893
3151
3425
3716

Rpm
1418
1428
1439
1452
1466

2.0
Bhp
3.29
3.52
3.76
4.02
4.30

Watts
2839
3033
3242
3467
3708

Rpm
1139
1155
1171
1189
1209
1229
1250
1273

50TJ016 (15 TONS)* (cont)


Airflow
(Cfm)
4500
4800
5100
5400
5700
6000
6300
6600
6900
7200
7500

Rpm
1214
1228
1243
1259
1277
1295
1315

1.4
Bhp
2.59
2.80
3.04
3.29
3.56
3.84
4.15

Watts
2230
2417
2618
2835
3067
3316
3580

Watts
2736
2928
3136
3360
3600

1.2
Bhp
2.36
2.57
2.80
3.05
3.31
3.60
3.90
4.22

Bhp
Brake Horsepower
Watts Input Watts to Motor
Watts
2034
2217
2416
2629
2858
3103
3365
3642

*Standard low-medium static drive range is


891 to 1179 rpm (for 208/230 and 460-v
units) or 1159 to 1429 rpm (for 575-v units).
Alternate high-static drive range is 1227 to
1550 (for 208/230 and 460-v units). The
alternate high-static drive is not available for
50TJ016 575-v units. Other rpms require a
field-supplied drive.
NOTES:
1. Maximum continuous bhp is 4.25 (208/
230 and 460-v) or 3.45 (575-v) and the
maximum continuous watts are 3775
(208/230 and 460-v) or 3065 (575-v).
Do not adjust motor rpm such that
motor maximum bhp and/or watts is
exceeded at the maximum operating
cfm.
2. See this page for general fan performance notes.

GENERAL FAN PERFORMANCE NOTES


NOTES:
1. Values include losses for filters, unit casing, and wet coils. See page 118 for accessory/
factory-installed option static pressure information.
2. Extensive motor and electrical testing on these units ensures that the full range of the
motor can be utilized with confidence. Using your fan motors up to the wattage ratings
shown will not result in nuisance tripping or premature motor failure. Unit warranty will not

116

3.
4.

be affected. See Evaporator-Fan Motor Performance table on page 119 for additional
information.
Use of a field-supplied motor may affect wire sizing. Contact your Carrier representative
for details.
Interpolation is permissible. Do not extrapolate.

FAN PERFORMANCE 50TJ016-028 UNITS (cont)


50TJ020, 024 (18 and 20 TONS)*
Airflow
(Cfm)
5,500
6,000
6,500
7,000
7,500
8,000
8,500
9,000
9,500
10,000

Rpm
682
730
778
828
878
928
979
1030
1082
1134

0.2
Bhp
1.99
2.38
2.82
3.31
3.84
4.42
5.05
5.73
6.46
7.25

Watts
1675
2005
2373
2780
3227
3715
4245
4817
5433
6093

Rpm
760
802
846
892
938
985
1033
1082
1131
1180

0.4
Bhp
2.29
2.68
3.13
3.62
4.15
4.74
5.38
6.06
6.80
7.59

Rpm
1142
1167
1194
1224
1255
1289
1324
1360
1398
1438

1.6
Bhp
4.24
4.66
5.12
5.63
6.19
6.80
7.45
8.16
8.93
9.74

Watts
1922
2257
2630
3042
3494
3986
4521
5098
5718
6382

Available External Static Pressure (in. wg)


0.6
0.8
Rpm
Bhp Watts Rpm
Bhp Watts
832
2.59
2177
901
2.90
2441
871
2.99
2516
935
3.31
2783
911
3.44
2893
972
3.76
3164
953
3.94
3310
1011
4.26
3583
996
4.48
3766
1051
4.81
4043
1040
5.07
4263
1093
5.40
4544
1085
5.71
4801
1136
6.05
5086
1131
6.40
5382
1180
6.74
5671
1178
7.14
6007
1225
7.49
6299
1226
7.94
6675
1270
8.29
6971

Rpm
965
997
1031
1067
1105
1144
1185
1227
1270
1313

1.0
Bhp
3.22
3.63
4.09
4.59
5.14
5.74
6.39
7.09
7.84
8.65

Watts
2712
3057
3440
3863
4326
4830
5375
5964
6595
7271

Rpm
1249
1270
1294
1320
1348
1379
1411
1445
1480

2.0
Bhp
4.96
5.37
5.83
6.35
6.91
7.52
8.18
8.90
9.67

Watts
4167
4516
4906
5337
5810
6325
6883
7484
8129

Rpm
1027
1056
1087
1121
1156
1194
1232
1272
1313
1356

1.2
Bhp
3.56
3.97
4.43
4.93
5.49
6.09
6.74
7.44
8.20
9.01

Watts
2990
3337
3722
4148
4613
5120
5669
6260
6895
7574

50TJ020, 024 (18 and 20 TONS)* (cont)


Airflow
(Cfm)
5,500
6,000
6,500
7,000
7,500
8,000
8,500
9,000
9,500
10,000

Rpm
1086
1112
1142
1173
1207
1242
1279
1317
1356
1397

1.4
Bhp
3.89
4.31
4.77
5.28
5.83
6.44
7.10
7.80
8.56
9.37

Watts
3275
3623
4010
4438
4906
5415
5966
6561
7198
7881

Available External Static Pressure (in. wg)


1.8
1.9
Watts Rpm
Bhp Watts Rpm
Bhp
3567
1197
4.59 3864 1223
4.77
3915
1219
5.01 4213 1245
5.19
4304
1245
5.47 4602 1270
5.65
4733
1273
5.98 5033 1296
6.17
5203
1302
6.55 5504 1326
6.73
5714
1334
7.16 6018 1357
7.34
6268
1368
7.82 6573 1389
8.00
6865
1403
8.53 7173 1424
8.71
7505
1440
9.29 7815 1460
9.48
8190
1477 10.11 8503

LEGEND
Bhp Brake Horsepower
FIOP Factory-Installed Option
Watts Input Watts to Motor

NOTES:
1. Maximum continuous bhp for the 020 size is 5.90. Maximum continuous bhp
for the 024 size is 8.70 (208/230, 575 v) or 9.50 (460 v). The maximum continuous watts for the 020 size is 5180. The maximum continuous watts for
the 024 size is 7915 (208/230, 575 v) or 8640 (460 v). Do not adjust motor
rpm such that motor maximum bhp and/or watts is exceeded at the maximum operating cfm.
2. See page 116 for fan performance notes.

50TJ

*Standard low-medium static drive range for the 020 size is 910 to 1095 rpm.
Standard low-medium static drive range for the 024 size is 1002 to 1225 rpm.
Alternate high-static drive range for the 020 size is 1069 to 1287. Alternate highstatic drive range for the 024 size is 1193 to 1458 rpm. Other rpms require a
field-supplied drive.

Watts
4015
4364
4754
5184
5657
6171
6728
7328
7972

50TJ028 (25 TONS)*


Airflow
(Cfm)
7,000
7,500
8,000
8,500
9,000
9,500
10,000
10,500
11,000
11,250

Rpm
845
896
948
1001
1053
1106
1159
1213
1266
1293

0.2
Bhp
3.26
3.82
4.43
5.11
5.85
6.65
7.52
8.45
9.45
9.97

Watts
2693
3156
3667
4226
4836
5498
6214
6984
7810
8245

Rpm
909
956
1005
1054
1104
1155
1206
1257
1309
1334

0.4
Bhp
3.60
4.17
4.80
5.49
6.23
7.04
7.92
8.86
9.87
10.40

Watts
2979
3450
3969
4537
5155
5824
6547
7325
8159
8597

Available External Static Pressure (in. wg)


0.6
0.8
Rpm
Bhp Watts Rpm
Bhp Watts
969
3.96 3272
1028
4.32 3574
1014
4.54 3752
1069
4.91 4060
1060
5.17 4278
1112
5.56 4593
1106
5.87 4853
1156
6.26 5175
1154
6.63 5478
1202
7.02 5808
1202
7.44 6155
1248
7.85 6492
1251
8.33 6886
1295
8.74 7229
1300
9.28 7671
1342
9.70 8020
1350 10.29 8511
1391 10.73 8868
1375 10.83 8953
1415 11.26 9313

Rpm
1083
1123
1163
1205
1248
1293
1338
1384
1431
1454

1.0
Bhp
4.70
5.29
5.94
6.66
7.43
8.26
9.16
10.13
11.16
11.70

Watts
3883
4375
4915
5504
6142
6833
7577
8375
9229
9677

Rpm
1137
1174
1213
1253
1294
1336
1380
1424
1470
1493

1.2
Bhp
5.08
5.68
6.34
7.06
7.84
8.68
9.59
10.56
11.60
12.15

Watts
4,200
4,698
5,243
5,838
6,483
7,179
7,929
8,733
9,594
10,045

50TJ028 (25 TONS)* (cont)


Airflow
(Cfm)
7,000
7,500
8,000
8,500
9,000
9,500
10,000
10,500
11,000
11,250

Rpm
1189
1224
1261
1299
1338
1379
1421
1464
1508
1530

1.4
Bhp
5.47
6.08
6.75
7.47
8.26
9.11
10.02
11.00
12.05
12.60

Available External Static Pressure (in. wg)


1.6
1.8
Watts
Rpm
Bhp
Watts
Rpm
Bhp
4,524 1239
5.87
4,854 1288
4.91
5,026 1272
6.48
5,362 1320
5.56
5,577 1307
7.16
5,917 1353
6.26
6,177 1344
7.89
6,523 1388
7.02
6,828 1382
8.68
7,179 1424
7.85
7,530 1421
9.54
7,887 1462
8.74
8,286 1461 10.46
8,648 1501
9.70
9,096 1503 11.45
9,464 1541 10.73
9,963 1546 12.50 10,336

10,417

LEGEND
Bhp
Brake Horsepower
Watts Input Watts to Motor

*Standard low-medium static drive range is 1066 to 1283 rpm. Alternate highstatic drive range is 1332 to 1550. Other rpms require a field-supplied drive.

Watts
5191
5703
6263
6873
7534
8247
9014
9835

NOTES:
1. Maximum continuous bhp is 10.20 (208/230, 575 v) or 11.80 (460 v) and the
maximum continuous watts are 9510 (208/230, 575 v) or 11,000 (460 v). Do
not adjust motor rpm such that motor maximum bhp and/or watts is
exceeded at the maximum operating cfm.
2. See page 116 for fan performance notes.

117

Performance data 50TJ (cont)


OUTDOOR SOUND POWER
SOUND
RATING
(dB)
88 Bels
88 Bels
94 Bels
94 Bels

UNIT
50TJ
016
020
024
028

OCTAVE BANDS

A-WEIGHTED
(dB)

63

125

250

500

1000

2000

4000

8000

87.8
87.8
94.1
94.1

90.8
90.8
98.7
98.7

88.7
88.7
92.3
92.3

86.4
86.4
93.8
93.8

84.3
84.3
90.9
90.9

83.5
83.5
89.6
89.6

78.4
78.4
85.9
85.9

75.6
75.6
80.3
80.3

66.8
66.8
74.3
74.3

ACCESSORY/FIOP STATIC PRESSURE (in. wg)* 50TJ016


COMPONENT
EconoMi$er IV
Glycol Coil
Electric Heat (kW)
26/34
32
42/56
50
55
56/75
80
MoistureMi$er Dehumidification

4500
0.04
0.22

5000
0.05
0.26

CFM
6000
0.07
0.35

7200
0.09
0.44

7500
0.10
0.46

0.06
0.06
0.07
0.09
0.07
0.09
0.09
0.05

0.07
0.07
0.08
0.10
0.08
0.10
0.10
0.05

0.09
0.09
0.12
0.15
0.12
0.15
0.15
0.07

0.11
0.11
0.16
0.20
0.15
0.20
0.20
0.10

0.12
0.12
0.17
0.21
0.17
0.21
0.21
0.11

LEGEND
FIOP Factory-Installed Option
*The static pressure must be added to external static pressure. The sum and the evaporator entering-air cfm should
then be used in conjunction with the Fan Performance tables to determine blower rpm and watts.

ACCESSORY/FIOP STATIC PRESSURE (in. wg)* 50TJ020-028

50TJ

COMPONENT
EconoMi$er IV
Glycol Coil
Electric Heat (kW)
26/34
32
42/56
55
56/75
80
MoistureMi$er Dehumidification
FIOP

5400
0.06
0.30

6000
0.07
0.35

7200
0.09
0.44

CFM
9000
0.11
0.58

0.08
0.08
0.11
0.11
0.14
0.14
0.06

0.09
0.09
0.12
0.12
0.15
0.15
0.07

0.11
0.11
0.15
0.15
0.20
0.20
0.10

0.15
0.15
0.19
0.19
0.24
0.24
0.16

10,000
0.12
0.66

11,250
0.14
0.77

0.17
0.17
0.21
0.21
0.26
0.26
0.20

0.20
0.20
0.24
0.24
0.29
0.29
0.25

LEGEND
Factory-Installed Option

*The static pressure must be added to external static pressure. The sum and the evaporator entering-air cfm should
then be used in conjunction with the Fan Performance tables to determine blower rpm and watts.

FAN RPM AT MOTOR PULLEY SETTINGS*


UNIT
50TJ

1/
2

11/2

016 (208/230, 460 v)


016 (208/230, 460 v)**
016 (575 v)
020
020**
024
024**
028
028**

1179
1559
1429
1095
1287
1225
1458
1283

1150
1522
1403
1077
1265
1209
1434
1269

1121
1488
1376
1058
1243
1187
1407
1247
1550

*Approximate fan rpm shown.


Indicates standard drive package.
**Indicates alternate drive package.
Due to belt and pulley size, pulley cannot be set to this number of turns open.

118

MOTOR PULLEY TURNS OPEN


21/2
3
31/2
4
1093
1455
1349
1040
1222
1165
1381
1225
1524

1064
1422
1323
1021
1200
1143
1354
1203
1497

1035
1389
1296
1002
1178
1120
1328
1182
1470

1006
1356
1269
984
1156
1098
1301
1160
1443

41/2

51/2

978
1323
1242
965
1134
1076
1275
1138
1415

949
1289
1215
947
1112
1053
1248
1116
1388

920
1256
1188
928
1091
1031
1222
1095
1361

891
1227
1159
910
1069
1002
1193
1066
1332

EVAPORATOR-FAN MOTOR PERFORMANCE


UNIT
50TJ

UNIT
VOLTAGE
208/230
460
575
208/230
460
575
208/230
460
575
208/230
460
575

016

020

024

028

BHP
BkW

MAXIMUM ACCEPTABLE
CONTINUOUS BHP*
4.25
4.25
3.45

MAXIMUM ACCEPTABLE
CONTINUOUS BkW*
3.17
3.17
2.59

MAXIMUM ACCEPTABLE
OPERATING WATTS
3,775
3,775
3,065

5.90

4.40

5,180

8.70
9.50
8.70
10.20
11.80
10.20

6.49
7.08
6.49
7.61
8.80
7.61

7,915
8,640
7,915
9,510
11,000
9,510

LEGEND
Brake Horsepower
Brake Kilowatts

MAXIMUM
AMP DRAW
10.5
4.8
3.9
15.8
7.9
6.0
22.0
13.0
10.0
28.0
14.6
13.0

NOTE: All indoor-fan motors 5 hp and larger meet the minimum efficiency requirements
as established by the Energy Policy Act of 1992 (EPACT) effective October 24, 1997.

*Extensive motor and electrical testing on these units ensures that the full horsepower
(brake kilowatt) range of the motors can be utilized with confidence. Using your fan
motors up to the horsepower (brake kilowatt) ratings shown in this table will not result in
nuisance tripping or premature motor failure. Unit warranty will not be affected.

EVAPORATOR-FAN MOTOR EFFICIENCY


UNIT
50TJ
016 (3.0 Hp)
016 (3.7 Hp)
020 (5 Hp)
024 (7.5 Hp)
028 (10 Hp)

FAN PERFORMANCE USING ACCESSORY POWER


EXHAUST (50TJ016-028)

MOTOR EFFICIENCY
(%)
81.7
85.8
87.5
88.5
89.5

NOTE: All indoor-fan motors 5 hp and larger meet the minimum efficiency requirements
as established by the Energy Policy Act of 1992 (EPACT) effective October 24, 1997.

50TJ

ELECTRIC RESISTANCE HEATER DATA 50TJ016-028


UNIT
50TJ

016

020

024

028

208
26
42
56
26
42
56
26
42
56
26
42
56

HEATER kW
Unit Voltages
230
460
34
32
56
55
75
80
34
32
56
55
75
80
34
32
56
55
75
80
34
32
56
55
75
80

575

50

HEATER
STAGES

HEAT
PER STAGE

MAXIMUM
STAGES*

2
2
2
2
2
2
2
2
2
2
2
2

50/50
33/67
50/50
50/50
33/67
50/50
50/50
33/67
50/50
50/50
33/67
50/50

2
3
4
2
3
4
2
3
4
2
3
4

MINIMUM
HEATING CFM
Cfm
L/s
4500

2124

5400

2549

6000

2832

7000

3304

*Maximum number of stages using accessory low-ambient kit or head pressure control device and low-ambient kit.
NOTE: Heaters are rated at 240, 480, and 600 v. Use the Multiplication Factors table below to determine heater capacity for your particular voltage.

MULTIPLICATION FACTORS
HEATER RATING
VOLTAGE
240
480
600

200
0.69

208
0.75

230
0.92

240
1.00

ACTUAL HEATER VOLTAGE


440
460

0.84
0.92

480

1.00

550

0.84

575

0.92

600

1.00

NOTE: The following equation converts kW of heat energy to Btuh: kW x 3.413 = Btuh.
EXAMPLE: 34 kW (at 230 v) heater on 208 v
= 34.0 (.751 mult factor)
= 25.5 kW capacity at 208 v.

119

Electrical data 50TJ


UNIT
50TJ

NOMINAL VOLTAGE
COMPRESSOR
OFM
IFM
VOLTAGE RANGE
No. 1
No. 2
(3 Ph,
Min Max RLA LRA RLA LRA Qty Hp FLA (ea) Hp
FLA
60 Hz)

208/230

187

253

25.6 190 25.6 190

0.5

1.7

3.7 10.5/11.0

460

414

508

13.5

95

13.5

95

0.5

0.8

3.7

4.8

575

518

632

10.2

75

10.2

75

0.5

0.75

3.0

3.9

208/230

187

253

33

237

23

184

0.5

1.7

5.0 15.8/15.8

460

414

508

16.2 130 10.2

90

0.5

0.8

5.0

7.9

575

518

633

12.7

73

0.5

0.75

5.0

6.0

208/230

187

253

33

237 29.5 237

6.6

7.5 25.0/25.0

460

414

508

16.2 130 14.1 130

3.3

7.5

13.0

575

518

632

12.7

3.4

7.5

10.0

50TJ

016
(15 Tons)

020
(18 Tons)

85

024
(20 Tons)

120

85 11.3

85

POWER
EXHAUST
FLA LRA

4.6

4.6

4.6

4.6

2.3

2.3

2.3

2.3

2.1

2.1

4.6

4.6

4.6

4.6

2.3

2.3

2.3

2.3

2.1

4.6

4.6

4.6

4.6

2.3

2.3

2.3

2.3

2.1

18.8

18.8

18.8

18.8

6.0

6.0

6.0

6.0

4.8

4.8

18.8

18.8

18.8

18.8

6.0

6.0

6.0

6.0

4.8

18.8

18.8

18.8

18.8

6.0

6.0

6.0

6.0

4.8

ELECTRIC
HEAT*

POWER
SUPPLY

kW

FLA

MCA

MOCP

26/34
26/34
42/56
42/56
56/75**
56/75**

32
32
55
55
80**
80**

50**
50**

26/34
26/34
42/56
42/56
56/75**
56/75**

32
32
55
55
80**
80**

26/34
26/34
42/56
42/56
56/75**
56/75**

32
32
55
55
80**
80**

71/82
71/82
117/135
117/135
156/180
156/180

39
39
66
66
96
96

48
48

71/82
71/82
117/135
117/135
156/180
156/180

39
39
66
66
96
96

71/82
71/82
117/135
117/135
156/180
156/180

39
39
66
66
96
96

73/74
78/78
102/116
108/122
159/149
165/155
169/194
175/200
38
40
55
58
72
75
102
105
29
31
53
56
85/85
90/90
109/122
114/128
166/155
172/161
176/200
182/206
41
43
59
62
76
79
106
109
33
35
109/109
114/114
120/134
126/140
178/166
183/172
187/211
193/217
54
56
65
68
82
85
112
115
44
46

90/90
100/100
110/125
110/125
175/175
175/175
200/225
200/225
50
50
60
60
80
80
110
110
35
40
60
60
110/110
110/110
110/125
125/150
175/175
175/175
200/225
200/225
50
50
60
70
90
90
125
125
45
45
125/125
125/125
125/150
150/150
200/175
200/175
200/225
200/225
70
70
70
70
90
90
125
125
50
50

NOMINAL VOLTAGE
COMPRESSOR
OFM
VOLTAGE RANGE
No. 1
No. 2
(3 Ph,
Min Max RLA LRA RLA LRA Qty Hp FLA (ea)
60 Hz)

UNIT
50TJ

33

Hp

FLA

FLA LRA

208/230

187

253

47.5 265

237

6.6

10.0 28.0/28.0

460

414

508

22.9 145 16.2 130

3.3

10.0

14.6

575

518

632

17.9 102 12.7

3.4

10.0

13.0

028
(25 Tons)

FLA
HACR
IFM
LRA
MCA
MOCP
NEC
OFM
RLA

POWER
EXHAUST

IFM

85

LEGEND
Full Load Amps
Heating, Air Conditioning and Refrigeration
Indoor (Evaporator) Fan Motor
Locked Rotor Amps
Minimum Circuit Amps
Maximum Overcurrent Protection
National Electrical Code
Outdoor (Condenser) Fan Motor
Rated Load Amps

kW

POWER
SUPPLY

FLA

18.8

26/34
71/82
18.8 26/34
71/82

42/56 117/135
18.8 42/56 117/135
56/75** 156/180
18.8 56/75** 156/180

6.0

32
39
6.0
32
39

55
66
6.0
55
66

80**
96
6.0
80**
96

4.8

MCA

MOCP

134/134
138/138
134/138
138/143
181/170
187/176
191/215
197/221
66
68
67
70
84
87
114
117
55
57

175/175
175/175
175/175
175/175
200/175
200/200
200/225
200/225
80
90
80
90
90
100
125
125
70
70

Example: Supply voltage is 460-3-60.


AB = 452 v
BC = 464 v
AC = 455 v
Average Voltage =
=

452 + 464 + 455


3
1371
3

= 457
Determine maximum deviation from average voltage.
(AB) 457 452 = 5 v
(BC) 464 457 = 7 v
(AC) 457 455 = 2 v
Maximum deviation is 7 v.
Determine percent of voltage imbalance.
7
% Voltage Imbalance = 100 x
457

50TJ

*Heater capacity (kW) is based on heater voltage of 208 v, 240 v,


480 v, and 575 v. Heaters are rated at 240 v, 480 v, or 600 v. If power
distribution voltage to unit varies from rated heater voltage, heater kW
will vary accordingly.
Fuse or HACR circuit breaker.
**Heaters are field installed only.
NOTES:
1. In compliance with NEC requirements for multimotor and combination load equipment (refer to NEC Articles 430 and 440), the overcurrent protective device for the unit shall be fuse or HACR breaker.
Canadian units may be fuse or circuit breaker.
2. Unbalanced 3-Phase Supply Voltage
Never operate a motor where a phase imbalance in supply voltage is
greater than 2%. Use the following formula to determine the percent
of voltage imbalance.
% Voltage Imbalance
max voltage deviation from average voltage
= 100 x
average voltage

4.6

4.6

4.6

4.6

2.3

2.3

2.3

2.3

2.1

ELECTRIC
HEAT*

= 1.53%
This amount of phase imbalance is satisfactory as it is below the maximum allowable 2%.
IMPORTANT: If the supply voltage phase imbalance is
more than 2%, contact your local electric utility company
immediately.
3. MCA calculation for units with electric heaters over 50 kW = (1.25 x
IFM amps) + (1.00 x heater FLA).

121

Typical wiring schematics 50TJ


TYPICAL WIRING SCHEMATIC (50TJ024, 208/230-3-60 SHOWN)

50TJ

A
B
C

122

ELECTRIC HEAT
208/240 v Amps
200/230 v kW
71.3/82.3
25.7/34.2
117/135
42.2/56.1
156/180
56.2/74.8

LEGEND AND NOTES FOR TYPICAL WIRING SCHEMATICS


LEGEND
AHA

BRK W/AT
C

CB

CC

CLO

COMP

CR

DU

EQUIP

FL

FLA

FPT

FU

GND

HC

HPS

HTR

Adjustable Heat Anticipator


Breaks with Amp Turns
Contactor, Compressor
Circuit Breaker
Cooling Compensator
Compressor Lockout
Compressor Motor
Control Relay
Dummy Terminal
Equipment
Fuse Link
Full Load Amps
Freeze Protection Thermostat
Fuse
Ground
Heater Contactor
High-Pressure Switch
Heater

IFC
IFCB
IFM
IFR
L
LOR
LPS
LS
NEC
OFC
OFM
OP
PL
PRI
TB
TC
TH
TRAN

Indoor-Fan Contactor
Indoor-Fan Circuit Breaker
Indoor-Fan Motor
Indoor-Fan Relay
Light
Lockout Relay
Low-Pressure Switch
Limit Switch
National Electrical Code
Outdoor-Fan Contactor
Outdoor-Fan Motor
Overcurrent Protection
Plug Assembly
Primary
Terminal Block
Thermostat Cooling
Thermostat Heating
Transformer

Terminal (Marked)
Terminal (Unmarked)
Terminal Block
Splice
Factory Wiring
Field Control Wiring
Option/Accessory Wiring
To indicate common potential
only; not to represent wiring.

NOTES:
1. Compressor and fan motor(s) thermally protected; 3-phase motors protected against primary single-phasing
conditions.
2. If any of the original wire furnished must be replaced, it must be replaced with type 90 C wire or its equivalent.
3. TRAN1 is wired for 230 v (60 Hz) or 220 v (50 Hz) operation. If unit is 208 v, disconnect the black wires from the
ORN TRAN wire and reconnect to the RED TRAN wire, apply wirenuts to wires.
5. IFCB must trip amps is equal to or less than 140% FLA.
6. The CLO locks out the compressor to prevent short cycling on compressor overload and safety devices. Before
replacing CLO, check these devices.
7. Jumpers are omitted when unit is equipped with economizer.
8. Number(s) indicates the line location of used contacts. A bracket over (2) numbers signifies a single-pole, doublethrow contact. An underlined number signifies a normally closed contact. Plain (no line) number signifies a normally
open contact.

50TJ

ECONOMI$ER IV WIRING 50TJ016-028

AL
ECB
IA
IAQ

Ambient Limit
Economizer Control Board
Indoor Air
Indoor Air Quality

LEGEND
OA
OAS
RAS
SAT

905

Outdoor Air
Outdoor Air Sensor
Return Air Sensor
Supply Air Temperature

123

Typical wiring schematics 50TJ (cont)


ECONOMI$ER2 WIRING 50TJ016-028
4
3
7
RED
500 OHM
RESISTOR

8
PINK

NOTE 1
BLUE

RUN

OAT
BLACK

NOTE 2

1
10

50HJ540573
ACTUATOR
ASSEMBLY

11
9
WHITE

50TJ

DIRECT DRIVE
ACTUATOR

LEGEND
OAT Outdoor Air Temperature Sensor
NOTES:
1. Switch on actuator must be in run position for economizer to operate.
2. 50HJ540573 actuator consists of the 50HJ540567 actuator and a harness with 500-ohm resistor.

12

ECONOMISER2 PLUG

NON-FUSED DISCONNECT (OPTIONAL) 50TJ016-028

NOTES:
1. If the Non-Fused Disconnect Service Option is ordered for size 016-028 units, the Non-Fused Disconnect will be factory-installed.
2. The Disconnect takes the place of TB-1 as shown on the unit wiring diagram label and the component arrangement label.

124

Typical piping and wiring 50TJ016-028


(50TJ016 shown)

50TJ

LEGEND
NEC National Electrical Code
NOTES:
1. Illustration shown is a general guide only and is not intended to include all details for any specific installation.
2. Installation must comply with all applicable codes.
3. A 90-degree elbow must be installed on the supply ductwork below the unit discharge for units equipped with electric heat.

125

Guide specifications 50TJ016-028


Packaged Rooftop Electric Cooling Unit with
Electric or Glycol Heat Constant Volume
Application
HVAC Guide Specifications
Size Range: 15 to 25 Tons Nominal (Cooling),
26 to 80 kW Nominal (Electric Heating),
123,000 to 405,000 Btuh Nominal
(Glycol Heating Coil)

50TJ

Carrier Model Number:


50TJ
Part 1 General
1.01 SYSTEM DESCRIPTION
Unit is an outdoor rooftop mounted, electrically controlled heating and cooling unit utilizing scroll hermetic compressors for cooling duty and electric or
glycol coils for heating duty. Supply air shall be discharged downward or horizontally (with horizontal
supply/return curb adapter assembly), as shown on
contract drawings. Standard unit shall include a
manual outdoor-air inlet.
1.02 QUALITY ASSURANCE
A. Unit shall be rated in accordance with ARI
Standards 270 and 360 and all units shall be
designed in accordance with UL Standard 1995.
NOTE: Size 028 units are beyond the scope of ARI
certification guidelines.
B. Unit shall be designed to conform to ASHRAE 15.
C. Unit shall be ETL and ETL, Canada tested and certified in accordance with ANSI Z21.47 Standards as a
total package.
D. Roof curb shall be designed to conform to NRCA
Standards.
E. Insulation and adhesive shall meet NFPA 90A
requirements for flame spread and smoke
generation.
F. Unit casing shall be capable of withstanding
500-hour salt spray exposure per ASTM B117
(scribed specimen).
G. Unit shall be manufactured in a facility registered to
ISO 9001:2000.
1.03 DELIVERY, STORAGE, AND HANDLING
Unit shall be stored and handled per manufacturers
recommendations.
Part 2 Products
2.01 EQUIPMENT (STANDARD)
A. General:
Each unit shall be a factory assembled, single-piece
heating and cooling unit. Contained within the unit
enclosure shall be all factory wiring, piping, controls,
refrigerant charge (R-22), and special features
required prior to field start-up.

126

B. Unit Cabinet:
1. Constructed of galvanized steel (G90 1.8 oz.
of zinc per square foot of sheet metal), bonderized and primer-coated on both sides and
coated with a baked polyester thermosetting
powdercoating finish on the outer surface.
2. Indoor blower compartment interior surfaces
shall be insulated with a minimum 1/2-in. thick,
1 lb density fiberglass insulation. Fiberglass
insulation shall be bonded with a thermosetting
resin (8 to 12% by weight nominal, phenol
formaldehyde typical), and coated with an
acrylic or other material that meets the
NFPA 90 flame retardance requirements and
has an R Value of 3.70.
3. Cabinet panels shall be easily removable for
servicing. Cabinet panels are minimum
20 gage. Panels shall have 1/2-in. thick, 1.5-lb
density insulation.
4. Filters shall be accessible through an access
panel.
5. Holes shall be provided in the base rails (minimum 12 gage) for rigging shackles to facilitate
overhead rigging.
6. Unit shall contain a sloped drain pan, to prevent standing water from accumulating. Pan
shall be fabricated of hot dipped zinc coated
minimum spangle steel. Zinc coating shall be
G90 designation according to ASTM Standard
A653. Unit shall contain a factory-installed
nonferrous main condensate drain connection.
C. Fans:
1. Indoor blower (evaporator fan):
a. Fan shall be belt driven. Belt drive shall
include an adjustable pulley. The standard
fan drive shall have a factory-installed lowmedium static pressure fan drive. The alternate fan drive option shall have a factoryinstalled high static pressure fan drive.
b. Fan wheel shall be made from steel with a
corrosion resistant finish. It shall be a
dynamically balanced, double-inlet type with
forward-curved blades.
2. Condenser fans shall be of the direct-driven
propeller type, with corrosion-resistant blades
riveted to corrosion-resistant steel supports.
They shall be dynamically balanced and discharge air upwards.
D. Compressor(s):
1. Fully hermetic, scroll type, internally protected.
2. Factory spring-shock mounted and internally
spring mounted for vibration isolation.
3. On electrically and mechanically independent
refrigerant circuits.
4. All compressors shall have 70 W crankcase
heaters.

K. Motors:
1. Compressor motors shall be cooled by refrigerant gas passing through motor windings and
shall have line break thermal and current overload protection.
2. All fan motors shall have permanently lubricated, sealed bearings and inherent automaticreset thermal overload protection or manual
reset calibrated circuit breakers. Evaporator
motors are designed specifically for Carrier and
do NOT have conventional horsepower (hp)
ratings listed on the motor nameplate. Motors
are designed and qualified in the air-over location downstream of the cooling coil and carry a
maximum continuous bhp rating that is the
maximum application bhp rating for the motor;
no safety factors above that rating may be
applied.
3. All indoor-fan motors 5 hp and larger shall
meet the minimum efficiency requirements as
established by the Energy Policy Act of 1992
(EPACT) effective October 24, 1997.
L. Special Features:
Certain features are not applicable when the features designated * are specified. For assistance in
amending the specifications, contact your local
Carrier Sales Office.
* 1. Carrier PremierLink Controls:
a. Shall be available as a factory-installed or as
a field-installed accessory.
b. Shall work with CCN and ComfortVIEW
software.
c. Shall be compatible with ComfortLink
controllers.
d. Shall be ASHRAE 62-2001 compliant.
e. Shall accept a CO2 sensor in the conditioned
space Demand Control Ventilation (DCV)
Ready.
f. Shall have baud communication rate of
38.4K or faster.
g. Shall be Internet Ready.
h. Shall include an integrated economizer
controller.
2. Optional Coils:
a. Optional pre-coated aluminum-fin coils shall
have a durable epoxy-phenolic coating to
provide protection in mildly corrosive coastal
environments. Coating shall be applied to
the aluminum fin stock prior to the fin
stamping process to create an inert barrier
between the aluminum fin and copper tube.
Epoxy-phenolic barrier shall minimize galvanic action between dissimilar metals.
b. Optional copper-fin coils shall be constructed of copper fins mechanically bonded
to copper tubes and copper tube sheets.
Galvanized steel tube sheets shall not be
127

50TJ

E. Coils:
1. Standard evaporator and condenser coils shall
have aluminum plate fins mechanically bonded
to seamless internally grooved copper tubes
with all joints brazed.
2. Coils shall be leak tested at 150 psig and pressure tested at 450 psig.
F. Refrigerant Components:
Refrigerant circuit components shall include:
1. Thermostatic expansion valve (TXV).
2. Filter driers.
3. Gage port and connections on suction, discharge, and liquid lines.
G. Filter Section:
Standard filter section shall consist of 2 sizes of
factory-installed 2-in. thick throwaway fiberglass filters of commercially available sizes. Filters shall be
approximately 10% efficient with an airside pressure
drop of approximately 0.07 in. wg (clean).
H. Controls and Safeties:
1. Unit Controls:
a. Economizer control (optional).
b. Capacity control (2-step).
c. Unit shall be complete with self-contained
low-voltage control circuit.
2. Safeties:
a. Unit shall incorporate a solid-state compressor lockout which provides reset capability at
the space thermostat, should any of the
following safety devices trip and shut off
compressor:
1) Compressor lockout protection provided
for either internal or external overload.
2) Low-pressure switch.
3) Dual freezestats (evaporator coil).
4) High-pressure switch.
b. Supply-air thermostat shall be located in the
unit.
c. Heating section shall be provided with a
high-temperature limit switch.
I. Operating Characteristics:
1. Unit shall be capable of starting and running at
120 F (size 016-025) or 125 F (size 028) ambient outdoor temperature per maximum load
criteria of ARI Standard 360.
2. Unit with standard controls will operate in cooling down to an outdoor ambient temperature of
40 F.
3. Unit shall be provided with fan time delay to
prevent cold air delivery.
J. Electrical Requirements:
All unit power wiring shall enter unit cabinet at a
single location.

Guide specifications 50TJ016-028 (cont)

50TJ

acceptable. A polymer strip shall prevent


coil assembly from contacting the sheet
metal coil pan to minimize potential for galvanic corrosion between coil and pan. All
copper construction shall provide protection
in moderate coastal environments.
c. Optional E-Coated aluminum-fin coils shall
have a flexible epoxy polymer coating uniformly applied to all coil surface areas without material bridging between fins. Coating
process shall ensure complete coil encapsulation. Color shall be high gloss black with
gloss 60 deg of 65 to 90% per
ASTM D523-89. Uniform dry film thickness
from 0.8 to 1.2 mil on all surface areas
including fin edges. Superior hardness characteristics of 2H per ASTM D3363-92A
and cross-hatch adhesion of 4B-5B per
ASTM D3359-93. Impact resistance shall be
up to 160 in./lb (ASTM D2794-93). Humidity and water immersion resistance shall be
up to minimum 1000 and 250 hours respectively (ASTM D2247-92 and ASTM D87092). Corrosion durability shall be confirmed
through testing to be no less than
1000 hours salt spray per ASTM B117-90.
Coil construction shall be aluminum fins
mechanically bonded to copper tubes.
d. Optional E-Coated copper-fin coils shall have
a flexible epoxy polymer coating uniformly
applied to all coil surface areas without material bridging between fins. Coating process
shall ensure complete coil encapsulation.
Color shall be high gloss black with gloss
60 deg of 65 to 90% per ASTM D523-89.
Uniform dry film thickness from 0.8 to
1.2 mil on all surface areas including fin
edges. Superior hardness characteristics of
2H per ASTM D3363-92A and cross-hatch
adhesion of 4B-5B per ASTM D3359-93.
Impact resistance shall be up to 160 in./lb
(ASTM D2794-93). Humidity and water
immersion resistance shall be up to minimum 1000 and 250 hours respectively
(ASTM D2247-92 and ASTM D870-92).
Corrosion durability shall be confirmed
through testing to be no less than
1000 hours salt spray per ASTM B117-90.
Coil construction shall be copper fins
mechanically bonded to copper tubes with
copper tube sheets. Galvanized steel tube
sheets shall not be acceptable. A polymer
strip shall prevent coil assembly from contacting sheet metal coil pan to maintain coating integrity and minimize corrosion
potential between coil and pan.
3. Roof Curbs (Horizontal and Vertical):
a. Formed of 16-gage galvanized steel with
wood nailer strip and shall be capable of
supporting entire unit weight.

128

905

b. Permits installing and securing ductwork to


curb prior to mounting unit on the curb.
4. Horizontal Adapter Roof Curb:
Includes factory-assembled adapter and internal
duct.
NOTE: Power exhaust or barometric relief must
be mounted in the return ductwork when used
in conjunction with this accessory.
5. Integrated Economizers:
a. Integrated integral modulating type capable
of simultaneous economizer and compressor
operation.
b. Available as a factory-installed option in vertical supply/return configuration only. (Available as a field-installed accessory for
dedicated horizontal and/or vertical supply
return configurations.)
c. Includes all hardware and controls to provide
cooling with outdoor air.
d. Equipped with low-leakage dampers, not to
exceed 2% leakage at 1 in. wg pressure
differential.
e. Capable of introducing up to 100% outdoor
air.
f. EconoMi$er IV and EconoMi$er2 shall be
equipped with a barometric relief damper
capable of relieving up to 100% return air.
g. Designed to close damper(s) during loss-ofpower situations with spring return built into
motor.
h. Dry bulb outdoor-air temperature sensor
shall be provided as standard. Outdoor air
sensor set point is adjustable and shall range
from 40 to 100 F. For the EconoMi$er IV,
the return air sensor, indoor enthalpy sensor,
and outdoor enthalpy sensor shall be provided as field-installed accessories to provide
enthalpy control, differential enthalpy control, and differential dry bulb temperature
control. For the EconoMi$er2, the enthalpy,
differential temperature (adjustable), and differential enthalpy control shall be provided
as field-installed accessories.
i. The EconoMi$er IV and EconoMi$er2 shall
have a gear-driven parallel blade design.
j. EconoMi$er IV microprocessor control shall
provide control of internal building pressure
through its accessory power exhaust function. Factory set at 100%, with a range of
0% to 100%.
k. EconoMi$er2 shall be capable of control
from a 4 to 20 mA signal through optional
4 to 20 mA design without microprocessor
control (required for PremierLink or third
party control interface).

905

9. Barometric Relief Damper Package:


a. Package shall include damper, seals, hardware, and hoods to relieve excess internal
pressure.
b. Damper shall close due to gravity upon unit
shutdown.
c. Damper package must be field-installed in
return-air ductwork when used with optional
side return connections.
10. Power Exhaust:
Package shall include an exhaust (propeller
style) fan, 1/2 Hp 208-230, 460 v
(factory-wired for 460 v) direct drive motor, and
damper for vertical flow units with economizer
to control over-pressurization of building.
Power Exhaust package must be field-installed
in return-air ductwork when used with optional
side return connections.
*11. Head Pressure Control Package:
Package consists of an accessory outdoor-air
package and a solid-state control with condenser coil temperature sensor for controlling
condenser-fan motor speed to maintain condensing temperature between 90 F and 100 F
at outdoor ambient temperature down to 20 F
(size 016-025 only).
12. Low-Ambient Kits:
When used, kits allow units to operate at lower
outdoor ambient temperatures. Sizes 016, 020,
and 028 will operate down to 10 F. Size 025
will operate down to 25 F.
*13. Electronic Programmable Thermostat:
Unit shall be capable of using deluxe fullfeatured electronic thermostat.
14. Winter Start Time-Delay Relay:
Used in conjunction with the accessory lowambient kit or head pressure control device,
relay permits operation in cooling at lower outdoor ambient temperatures. See price pages for
more information.
15. Service Option Package:
a. Hinged access panels for the filter, compressors, evaporator fan, and control box areas.
Filter hinged access panels permit tool-less
entry for changing filters. Evaporator fan
hinged access panel shall be field-convertible
to a tool-less entry by removing and discarding screws. Each external hinged access
panel shall be permanently attached to the
rooftop unit.
b. Convenience outlet shall be factory-installed
and internally mounted with an externally
accessible 115-v, 15 amp GFI, female
receptacle with hinged cover. Voltage
required to operate convenience outlet shall
be provided by a field-supplied and properly
fused separate branch circuit.
129

50TJ

l. EconoMi$er IV Microprocessor Occupied


Minimum Damper Position Setting maintains the minimum airflow into the building
during occupied period providing design
ventilation rate for full occupancy (damper
position during heating). A remote potentiometer may be used to override the set
point.
m. EconoMi$er IV Microprocessor Unoccupied
Minimum Damper Position Setting The
EconoMi$er IV dampers shall be completely
closed when the unit is in the occupied
mode.
n. EconoMi$er IV Microprocessor IAQ/DCV
Maximum Damper Position Setting Setting the maximum position of the damper
prevents the introduction of large amounts
of hot or cold air into the space. This position is intended to satisfy the base minimum
ventilation rate.
o. EconoMi$er IV Microprocessor IAQ/DCV
control modulates the outdoor-air damper
to provide ventilation based on the optional
2 to 10 vdc CO2 sensor input.
p. Compressor lockout sensor (opens at 35 F,
closes at 50 F).
q. Actuator shall be direct coupled to economizer gear, eliminating linkage arms and
rods.
r. Control LEDs:
1) When the outdoor air damper is capable
of providing free cooling, the Free
Cool LED shall illuminate.
2) The IAQ LED indicates when the module is on the DCV mode.
3) The EXH LED indicates when the
exhaust fan contact is closed.
s. Remote Minimum Position Control A
field-installed accessory remote potentiometer allows the outdoor air damper to be
opened or closed beyond the minimum
position in the occupied mode for modified
ventilation.
6. Two-Position Damper:
Two-position damper package shall include single blade damper and 24-v motor. Admits up to
25% outdoor air, and shall close upon unit shutoff. Damper shall cover 3.8-in. high by
17.75-in. wide (117.8 sq in.) opening in return
air upper panel.
7. Accessory Compressor Cycle Delay:
Compressor shall be prevented from restarting
for a minimum of 5 minutes after shutdown.
* 8. Thermostats and Subbases:
Thermostats and subbases shall provide staged
heating and cooling in addition to automatic (or
manual) changeover and fan control.

Guide specifications 50TJ016-028 (cont)

50TJ

16.

17.

18.

19.

130

c. Non-fused disconnect switch shall be


factory-installed, internally mounted, NEC
and UL approved. Non-fused switch shall
provide unit power shutoff. The control
access door shall be interlocked with the
non-fused disconnect. The disconnect switch
must be in the OFF position to open the
control box access door. Shall be accessible
from outside the unit and shall provide
power off lockout capability.
Electric Heater Package:
a. Fully assembled for installation. The packages are designed in accordance with UL
safety standards 1995 and listed by ETL.
Heater construction approved by UL 5306.
b. Heater element open coil resistance wire,
nickel-chrome alloy, 0.29 inches inside
diameter, strung through ceramic insulators
mounted on metal frame. Coil ends are
staked and welded to terminal screw slots.
c. Heater assemblies are provided with integral
fusing for protection of internal heater circuits not exceeding 48 amps each.
d. Auto reset thermo limit controls, magnetic
heater contactors (24 v coil) and terminal
block all mounted in electric heater control
box (minimum 18 ga. Galvanized steel)
attached to end of heater assembly.
e. Certain models (208-230/3/60, 42/56 and
56/75 kW) require an additional heater control box that contains a field power terminal
block, a field power wiring fuse block and
fuses (125 A, 250 V, class K5 or RK%);
included with the electric heater assembly
package.
f. All power wiring leads are 10 AWG and control wiring leads are 18 AWG, both rated at
105 deg. C.
Glycol Coil: (Hot Water Coil)
Coil shall be 2-row copper tube (1/2-in. OD)
with aluminum plate fins (15 fins/in.) and
(1.625 in. OD) copper headers. Input and output connections shall be (1.625 in. ODM)
copper stubs for sweat connections. Coil shall
be furnished with suitable support rails, end
plates, and hardware for ready field installation
in heater compartment.
Alternate Drive:
Alternate drive shall provide higher static drive
capability to enhance evaporator-fan performance rpm range.
Hail Guard (016-025):
Hail guard shall protect the condenser coil from
hail, flying debris, and damage by large objects
without increasing unit clearances.

905

20. Ultraviolet Germicidal Lamps:


Ultraviolet germicidal lamps are designed to
eliminate odor causing mold and fungus that
may develop in the wet area of the evaporator
section of the unit. The high output, low temperature germicidal lamps are field installed in
the evaporator section of the unit, aimed at the
evaporator coil and condensate pan. The short
wavelength ultraviolet light inhibits and kills
mold, fungus and microbial growth. The lamps
have an output rating at 45 F in 400 fpm airflow of 120 microwatts/cm2 at 1 meter.
21. Stainless Steel Condensate Pan:
Stainless steel condensate pans shall be available for condensate collection.
22. Indoor Air Quality (CO2) Room Sensor
(EconoMi$er IV):
Sensor shall have the ability to provide demand
ventilation control through the EconoMi$er IV.
The IAQ sensor shall be wall mounted with an
LED display in parts per million. The set point
shall have adjustment capability.
23. Return Air CO2 Sensor (EconoMi$er IV):
Sensor shall have the ability to provide demand
ventilation control through the EconoMi$er IV.
The IAQ sensor shall be duct mounted. The set
point shall have adjustment capability.
24. Outdoor Air Enthalpy Sensor (EconoMi$er IV
or EconoMi$er2):
The outdoor air enthalpy sensor shall be used
with the controller to provide single enthalpy
control. When used in conjunction with a return
air enthalpy sensor, the controller will provide
different enthalpy control. The sensor allows
the controller to determine if outside air is suitable for free cooling.
25. Return Air Enthalpy Sensor (EconoMi$er IV or
EconoMi$er2):
The return air enthalpy sensor shall be used
with the EconoMi$er IV or EconoMi$er2
device. When used in conjunction with an outdoor air enthalpy sensor, the controller will provide differential enthalpy control.
26. Return Air Temperature Sensor (EconoMi$er IV
or EconoMi$er2):
The return air temperature sensor shall be used
with the EconoMi$er IV or EconoMi$er2
device. When used in conjunction with the standard outdoor air temperature sensor, the controller will provide differential temperature
control.
27. MoistureMi$er Dehumidification Package:
The dehumidification package is a factoryinstalled option that provides increased dehumidification by further subcooling the hot liquid

humidity control adjusts indoor humidity based


on the outdoor temperature sensor.
30. Fan/Filter Status Switch:
Switch shall provide status of indoor (evaporator) fan (ON/OFF) or filter (CLEAN/DIRITY).
Status shall be displayed over communication
bus when used with direct digital controls or
with an indicator light at the thermostat.
31. Indoor
Air
Quality
(CO2)
Sensor
(EconoMi$er2):
a. Shall have the ability to provide demand ventilation indoor air quality (IAQ) control
through the EconoMi$er2 with an IAQ
sensor.
b. The IAQ sensor shall be available in duct
mount, wall mount, and wall mount with
LED display. The set point shall have adjustment capability.
c. Requires EconoMi$er2 or PremierLink
control options.
32. Manual Outdoor-Air Damper:
Manual damper package shall consist of
damper, birdscreen, and rainhood which can be
preset to admit up to 50% outdoor air for year
round ventilation.
50TJ

refrigerant leaving the condenser coil. The


package consists of a subcooling coil located on
the leaving airside of the evaporator coil. The
location of this coil in the indoor airstream
greatly enhances the latent capacity of the
units. The package shall be equipped with
crankcase heater(s), low pressure switch(es) and
thermostatic expansion valve(s) (TXV). Low
pressure switch(es) prevents evaporator coil
freeze-up and TXVs assure a positive superheat
condition. If the operation of the subcooling coil
is controlled by a field-installed, wall-mounted
humidistat, the dehumidification circuit will then
operate only when needed. Optional field
connections for the humidistat are made in the
low voltage compartment of the unit control
box.
28. Humidistat:
Field-installed, wall-mounted humidistat is used
to control activation of the dehumidification
package. The humidistat can be set for humidity
levels between 20% and 80% relative humidity.
29. Light Commercial Thermidistat Device:
Field-installed wall-mounted thermostat is used
to control temperature and activation of the
dehumidification package. The Thermidistat
device can be set for humidity settings from
50% to 90% relative humidity. Automatic

131

Physical data 50HJ

50HJ

UNIT 50HJ
NOMINAL CAPACITY (tons)
OPERATING WEIGHT (lb)
Unit
EconoMi$er IV
Humidi-MiZer Adaptive Dehumidification System
Roof Curb
COMPRESSOR
Quantity
Oil (oz)
REFRIGERANT TYPE
Expansion Device
Operating Charge (lb-oz)
Standard Unit
Unit With Humidi-MiZer Adaptive Dehumidification System
CONDENSER FAN
Quantity...Diameter (in.)
Nominal Cfm
Motor Hp...Rpm
Watts Input (Total)
CONDENSER COIL
Rows...Fins/in.
Total Face Area (sq ft)
EVAPORATOR FAN
Quantity...Size (in.)
Nominal Cfm
Maximum Continuous Bhp
Standard
High Static
Motor Frame
Standard
High Static
Fan Rpm Range
Standard
High Static
Motor Bearing Type
Maximum Fan Rpm
Motor Pulley Pitch Diameter A/B (in.)
Standard
High Static
Nominal Motor Shaft Diameter (in.)
Standard
High Static
Fan Pulley Pitch Diameter (in.)
Standard
High Static
Belt Quantity...Type...Length (in.)
Standard
High Static
Pulley Center Line Distance (in.)
Speed Change per Full Turn of
Movable Pulley Flange (rpm)
Standard
High Static
Movable Pulley Maximum Full Turns
From Closed Position
Standard
High Static
Factory Setting Full Turns Open
Standard
High Static
Factory Speed Setting (rpm)
Standard
High Static
Fan Shaft Diameter at Pulley (in.)
EVAPORATOR COIL
Standard Unit
Rows...Fins/in.
Total Face Area (sq ft)
Unit With Humidi-MiZer Adaptive Dehumidification System
Rows...Fins/in.
Total Face Area (sq ft)
HIGH-PRESSURE SWITCH (psig)
Standard Compressor Internal Relief (Differential)
Cutout
Reset (Auto.)
LOSS-OF-CHARGE/LOW-PRESSURE
SWITCH (Liquid Line) (psig)
Cutout
Reset (Auto.)
FREEZE-PROTECTION THERMOSTAT
Opens (F)
Closes (F)
OUTDOOR-AIR INLET SCREENS
RETURN-AIR FILTERS
Quantity...Size (in.)
LEGEND
Bhp Brake Horsepower
*Single-phase/three-phase.

132

004
3

005
4

006
5

007
6

435
50
15
115

445
50
23
115

465
50
25
115

540
50
29
115

1
42

1
53

1
50

1
60

Scroll

R-22
Acutrol Metering Device
5-8
12-5

10-2
18-8

10-0
12- 8
20-5
23-14
Propeller Type
1...22
1...22
1...22
1...22
3500
3500
4100
4100
1/ ...825
1/ ...825
1/ ...1100
1/ ...1100
8
8
4
4
180
180
320
320
High-Efficiency Enhanced Copper Tubes, Lanced Aluminum Fins
1...17
2...17
2...17
2...17
14.6
16.5
16.5
21.3
Centrifugal Type, Belt Drive
1...10 x 10
1...10 x 10
1...10 x 10
1...10 x 10
1200
1600
2000
2400
1.20
2.40

1.20
2.40

1.30/2.40*
2.90

2.40
2.90

48
56

48
56

56
56

56
56

680-1044
1075-1455
Ball
2100

770-1185
1075-1455
Ball
2100

1035-1460/1035-1460*
1300-1685
Ball
2100

1120-1585
1300-1685
Ball
2100

1.9/2.9
2.8/3.8

1.9/2.9
2.8/3.8

2.4/3.4
3.4/4.4

2.4/3.4
3.4/4.4

1/2
5/
8

1/2
5/
8

5/8
7/
8

5/8
7/
8

4.5
4.5

4.0
4.5

4.0
4.5

3.7
4.5

1...A...36
1...A...39
10.0-12.4

1...A...36
1...A...39
10.0-12.4

1...A...40
1...A...40
14.7-15.5

1...A...38
1...A...40
14.7-15.5

65
65

70
65

75
60

95
60

5
6

5
6

6
5

5
5

3
31/2

3
31/2

3
31/2

3
31/2

826
1233
5/
8

936
1233
5/
8

1248
1396
5/
8

1304
1396
5/
8

High-Efficiency Enhanced Copper Tubes, Aluminum Double-Wavy Fins


2...15
5.5

2...15
5.5

4...15
5.5

4...15
7.3

1...17
3.9

2...17
3.9

2...17
3.9

2...17
5.2

450 50
428
320

73
22 5
30
45
Cleanable. Screen size and quantity varies by option selected.
Throwaway
2...16 x 25 x 2
2...16 x 16 x 2

UNIT 50HJ
NOMINAL CAPACITY (tons)

009
81/2

012
10

014
121/2

755
75
44
143

895
75
51
143

915
75
51
143

930
75
51
143

2
53

2
53

2
50

2
60

Scroll
R-22
Acutrol Metering Device
7-10
8- 2

9- 8
8-13

9-6
10-9

9-8
9-5

17
18-3

19- 2
19-10

19-14
20- 3

19-6
19

Propeller Type
2...22
2...22
2...22
6500
7000
7000
1/ ...1100
1/ ...1100
1/ ...1100
4
4
4
650
650
650
High-Efficiency Enhanced Copper Tubes, Lanced Aluminum Fins
2...17
2...17
2...17
2...17
20.5
25.0
25.0
25.0
Centrifugal Type, Belt Drive
15 x 15
15 x 15
15 x 15
15 x 15
3000
3400
4000
5000

2...22
6500
1/ ...1100
4
650

2.90
4.20
56

2.90
4.20
56

3.70
5.25
56

5.25

56

840-1085
860-1080
Ball
2100

840-1085
860-1080
Ball
2100

860-1080
830-1130
Ball
2100

830-1130

Ball
2100

3.4/4.4
4.0/5.0
7/8

3.4/4.4
4.0/5.0
7/8

4.0/5.0
2.8/3.8
7/8

2.8/3.8

7/8

7.0
8.0

7.0
8.0

8.0
5.8

5.8

1...A...48
1...A...53
16.75-19.25

1...A...51
1...A...53
16.75-19.25

1...A...53
1...BX...45
15.85-17.50

1...BX...48

15.85-17.50

50
60

50
60

45
60

60

5
5
5

5
5
5

5
6
5

840
840
860
887
860
860
890

1
1
1
1
High-Efficiency Enhanced Copper Tubes, Aluminum Double-Wavy Fins, Face Split
3...15
8.9

4...15
11.1

4...15
11.1

4...15
11.1

2...17
6.3

2...17
8.4

2...17
8.4

2...17
8.4

450 50
428
320

50HJ

OPERATING WEIGHT (lb)


Unit
EconoMi$er IV
Humidi-MiZer Adaptive Dehumidification System
Roof Curb
COMPRESSOR
Quantity
Oil (oz) (each compressor)
REFRIGERANT TYPE
Expansion Device
Operating Charge (lb-oz)
Standard Unit
Circuit 1
Circuit 2
Unit With Humidi-MiZer Adaptive Dehumidification System
Circuit 1
Circuit 2
CONDENSER FAN
Quantity...Diameter (in.)
Nominal Cfm
Motor Hp...Rpm
Watts Input (Total)
CONDENSER COIL
Rows...Fins/in.
Total Face Area (sq ft)
EVAPORATOR FAN
Size (in.)
Nominal Cfm Standard
Maximum Continuous Bhp
Standard
High Static
Motor Frame
Fan Rpm Range
Standard
High Static
Motor Bearing Type
Maximum Fan Rpm
Motor Pulley Pitch Diameter A/B (in.)
Standard
High Static
Nominal Motor Shaft Diameter (in.)
Fan Pulley Pitch Diameter (in.)
Standard
High Static
Belt Quantity...Type...Length (in.)
Standard
High Static
Pulley Center Line Distance (in.)
Speed Change per Full Turn of
Movable Pulley Flange (rpm)
Standard
High Static
Movable Pulley Maximum Full Turns
From Closed Position
Standard
High Static
Factory Setting Full Turns Open
Factory Speed Setting (rpm)
Standard
High Static
Fan Shaft Diameter at Pulley (in.)
EVAPORATOR COIL
Standard Unit
Rows...Fins/in.
Total Face Area (sq ft)
Unit with Humidi-MiZer Adaptive Dehumidification System
Rows...Fins/in.
Total Face Area (sq ft)
HIGH-PRESSURE SWITCH (psig)
Standard Compressor Internal Relief (Differential)
Cutout
Reset (Auto.)
LOSS-OF-CHARGE/LOW-PRESSURE
SWITCH (Liquid Line) (psig)
Cutout
Reset (Auto.)
FREEZE-PROTECTION THERMOSTAT
Opens (F)
Closes (F)
OUTDOOR-AIR INLET SCREENS
RETURN-AIR FILTERS
Quantity...Size (in.)

008
71/2

73
22 5
30 5
45 5
Cleanable. Screen size and quantity varies with option selected.
Throwaway
4...16 x 20 x 2
4...20 x 20 x 2
4...20 x 20 x 2
4...20 x 20 x 2

LEGEND
Bhp Brake Horsepower

133

Physical data 50HJ (cont)


UNIT 50HJ

208/230

UNIT VOLTAGE
NOMINAL CAPACITY (tons)
OPERATING WEIGHT (lb)
Unit
Al/Al*
Al/Cu*
Cu/Cu*
EconoMi$er IV
EconoMi$er2
Roof Curb
MoistureMi$er Dehumidification Package
COMPRESSOR
Quantity...Model (Ckt 1, Ckt 2)
Number of Refrigerant Circuits
Crankcase Heater Watts
Loading (% of Full Capacity)
Oil (oz) (Ckt 1, Ckt 2)
REFRIGERANT TYPE
Expansion Device
Operating Charge (lb)**
Circuit 1
Circuit 2
CONDENSER FAN
Nominal Cfm
Quantity...Diameter (in.)
Motor Hp...Rpm
Watts Input (Total)
CONDENSER COIL
Rows...Fins/in.
Total Face Area (sq ft)
EVAPORATOR FAN
Quantity...Size (in.)
Type Drive
Nominal Cfm
Std Motor Hp
Opt Motor Hp
Motor Nominal Rpm
Std Maximum Continuous Bhp
Opt Maximum Continuous Bhp
Motor Frame Size
Fan Rpm Range
Motor Bearing Type
Maximum Allowable Rpm
Motor Pulley Pitch Dia.
Nominal Motor Shaft Diameter (in.)
Fan Pulley Pitch Diameter (in.)
Nominal Fan Shaft Diameter (in.)
Belt, Quantity...Type...Length (in.)

50HJ

Pulley Center Line Distance (in.)


Speed Change per Full Turn of Movable
Pulley Flange (Rpm)
Movable Pulley Maximum Full Turns
From Closed Position
Factory Speed
Factory Speed Setting (Rpm)

Low-Medium Static
High Static
Low-Medium Static
High Static
Low-Medium Static
High Static
Low-Medium Static
High Static
Low-Medium Static
High Static

Low-Medium Static
High Static

LEGEND
Aluminum
Brake Horsepower
Copper
Thermostatic Expansion Valve

*Evaporator coil fin material/condenser coil fin material.


Weight of 14-in. roof curb.

134

208/230

017
460

12

15

1575
1725
1855
90
85
200
40

1650
1800
1930
90
85
200
40

2...ZR72KC
2
70
0, 53, 100
60, 60

1...ZR94KC, 1...ZR72KC
2
70
0, 60, 100
85, 60

20.7
13.4

RETURN-AIR FILTERS
Quantity...Size (in.)

575

575

R-22
TXV

EVAPORATOR COIL
Rows...Fins/in.
Total Face Area (sq ft)
HIGH-PRESSURE SWITCH (psig)
Cutout
Reset (Auto.)
LOW-PRESSURE SWITCH (psig)
Cutout
Reset (Auto.)
FREEZE PROTECTION THERMOSTAT (F)
Opens
Closes
OUTDOOR-AIR INLET SCREENS
Quantity...Size (in.)

Al
Bhp
Cu
TXV

015
460

19.5
13.45

Propeller Type
10,500
10,500
3...22
3...22
1/ ...1050
1/ ...1050
2
2
1100
1100
Cross-Hatched 3/8-in. Copper Tubes, Aluminum Lanced, Aluminum Pre-Coated, or Copper Plate Fins
4...15
4...15
21.7
21.7
Centrifugal Type
2...12 x 12
2...12 x 12
Belt
Belt
5200
6000
2.9
3.0
5
3.7
N/A
1725
1745
3.13
3.38
6.13
4.26
N/A
N/A
56H
184T
895-1147
895-1147
873-1021
1040-1315
N/A
1025-1200
Ball
Ball
1,550
1,550
3.1/4.1
3.1/4.1
4.9/5.9
3.7/4.7
N/A
4.9/5.9
7/8
7/8
11/8
6.0
6.0
9.4
6.0
6.0
8.0
13/16
13/16
17/16
1...BX...45
1...BX...45
1...BX...50
1...BX...45
1...BX...45
1...BX...48
14.5-16.0
14.5-16.0
13.3-14.8
45
45
37
45
N/A
44
6
6
4
3.5
3.5
3.5
987
987
965
1155
N/A
1134
Cross-Hatched 3/8-in. Copper Tubes, Aluminum Lanced or Copper Plate Fins, Face Split
4...15
4...15
17.5
17.5
426
320
27
44
30 5
45 5
Cleanable
2...20 x 25 x 1
1...20 x 20 x 1
Throwaway
4...20 x 20 x 2
4...16 x 20 x 2
**Circuit 1 uses the lower portion of condenser coil and lower portion of evaporator coils, and Circuit 2 uses the upper portion of both coils.
Due to belt and pulley style, pulley cannot be set from 0 to 11/2 turns open.

OPERATING AND RIGGING WEIGHTS 50HJ015,017


BASE UNIT OPERATING WEIGHTS*
UNIT

015
lb
1575

50HJ

017
kg
714

lb
1650

kg
748

*Base unit weight does not include electric heaters, copper coils, economizer, power exhaust, barometric relief or crating. See
Options and Accessories table below for more information.
NOTE: For 015 and 017 unit sizes add 75 lb (34 kg) for domestic crating.

OPTIONS AND ACCESSORIES 50HJ015,017


(Weight Adders)
OPTION/
ACCESSORY
Barometric Relief Damper
Power Exhaust
Electric Heater
EconoMi$er IV
EconoMi$er2
Cu Condenser Coil
Cu Condenser and Evaporator Coils
Roof Curb (14-in. curb)
Horizontal Adapter Roof Curb (Preassembled)
Horizontal Adapter Roof Curb (Field-assembled)
Hail Guard
MoistureMi$er Dehumidification Package
Cu

lb
50
85
50
90
85
150
280
200
250
343
60
40

OPTION/ACCESSORY WEIGHTS
50HJ015
50HJ017
kg
lb
kg
23
50
23
39
85
39
23
50
23
41
90
41
39
85
39
68
150
68
127
280
127
91
200
91
113
250
113
156
343
156
27
60
27
18
40
18

LEGEND
Copper

020
18

024
20

028
25

2139

2187

2446

3
3
68...68...90

3
3
90...90...90

2
2
110...110...NA

TXV

TXV

TXV

13.1
12.7
15.2

13.8
13.9
15.5

21.8
20.3
NA

14,000
4...22

14,000
4...22

21,000
6...22

1/ ...1100
4

1/ ...1100
4

1/ ...1100
4

1400

1400

2100

2...17
57.78

2...17
57.78

2...17
66.67

2...15x11
Belt
7000
Ball
1400

2...15x11
Belt
8000
Ball
1400

2...15x11
Belt
10,000
Ball
1400

3...15
23.33

4...15
23.33

4...15
27.22

426
320

426
320

426
320

3...20x25

3...20x25

3...20x25

9...16x25

9...16x25

9...18x24

50HJ

UNIT 50HJ
NOMINAL CAPACITY (tons)
OPERATING WEIGHT (lb)
Al/Al
COMPRESSOR
Quantity
Number of Refrigerant Circuits
Oil (ounces) Ckt A...Ckt B...Ckt C
REFRIGERANT TYPE
Expansion Device
Operating Charge (lb)
Circuit A
Circuit B
Circuit C
CONDENSER FAN
Nominal Cfm (Total, all fans)
Quantity...Diameter (in.)
Motor Hp...Rpm
Watts Input (Total)
CONDENSER COIL
Rows...Fins/in.
Total Face Area (sq ft)
EVAPORATOR FAN
Quantity...Size
Type Drive
Nominal Cfm
Motor Bearing Type
Maximum Allowable Fan Rpm
EVAPORATOR COIL
Rows...Fins/in.
Total Face Area (sq ft)
HIGH-PRESSURE SWITCH (psig)
Cutout
Reset (Auto)
OUTDOOR-AIR INLET SCREENS
Quantity...Size (in.)
RETURN-AIR FILTERS
Quantity...Size (in.)
LEGEND
TXV Thermostatic Expansion Valve

135

Physical data 50HJ (cont)


EVAPORATOR FAN DATA 50HJ020-028 VERTICAL SUPPLY/RETURN UNITS
020

50HJ

50HJ

208/230
and 460 v

024
575 v

208/230
and 460 v

028
575 v

208/230
and 460 v

575 v

LOW RANGE
Motor Hp
N/A
N/A
3.7
5
5
5
Drive Motor Nominal Rpm
N/A
N/A
1725
1745
1745
1745
Drive Maximum Continuous Bhp
N/A
N/A
4.25
5.75
5.75
5.75
Drive Maximum Continuous Watts
N/A
N/A
3698
4900
4900
4900
Motor Frame Size
N/A
N/A
56HZ
184T
S184T
184T
7/ 8
11 / 8
11 / 8
11/8
Motor Shaft Diameter (in.)
N/A
N/A
Fan Rpm Range
N/A
N/A
685-939
751-954
687-873
687-873
Motor Pulley Min. Pitch Diameter (in.)
N/A
N/A
2.7
3.7
3.7
3.7
Motor Pulley Max. Pitch Diameter (in.)
N/A
N/A
3.7
4.7
4.7
4.7
Blower Pulley Pitch Diameter (in.)
N/A
N/A
6.8
8.6
9.4
9.4
Blower Pulley Shaft Diameter (in.)
N/A
N/A
1.1875
1.1875
1.1875
1.1875
Blower Pulley Type
N/A
N/A
Fixed
Fixed
Fixed
Fixed
Pulley Center Line Distance (in.)
N/A
N/A
11.293-13.544 9.81-13.055 9.81-13.055 9.81-13.055
Belt, Quantity...Type...Length (in.)
N/A
N/A
1...BX38
1...BX...40
1...BX...41
1...BX...41
Speed Change Per Turn Moveable Pulley (Rpm)
N/A
N/A
42
34
31
31
Moveable Pulley Maximum Full Turns
N/A
N/A
6
6
6
6
Factory Speed Setting (Rpm)
N/A
N/A
812
853
780
780
MID-LOW RANGE
Motor Hp
3.7
3
5
5
5
5
Motor Nominal Rpm
1725
1725
1745
1745
1745
1745
Maximum Continuous Bhp
4.25
3.45
5.75
5.75
5.75
5.75
Maximum Continuous Watts
3698
3149
4900
4900
4900
4900
Motor Frame Size
56HZ
56HZ
S184T
184T
S184T
184T
7/8
7/8
11/8
11 / 8
11 / 8
11/8
Motor Shaft Diameter (in.)
Fan Rpm Range
647-886
810-1072
949-1206
949-1206
805-1007
805-1007
Motor Pulley Min. Pitch Diameter (in.)
2.7
3.1
3.7
3.7
4.8
4.8
Motor Pulley Max. Pitch Diameter (in.)
3.7
4.1
4.7
4.7
6.0
6.0
Blower Pulley Pitch Diameter (in.)
7.2
6.6
6.8
6.8
10.4
10.4
Blower Pulley Shaft Diameter (in.)
1.1875
1.1875
1.1875
1.1875
1.1875
1.1875
Blower Pulley Type
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Pulley Center Line Distance (in.)
11.293-13.544 11.286-14.475 9.81-13.055
9.81-13.055 9.81-13.055 9.81-13.055
Belt, Quantity...Type...Length (in.)
1...BX...38
1...BX...38
1...BX...38
1...BX...38
1...BX...45
1...BX...45
Speed Change per Turn Moveable Pulley (Rpm)
40
44
43
43
34
34
Moveable Pulley Maximum Full Turns
6
6
6
6
6
6
Factory Speed Setting (Rpm)
767
941
1078
1078
906
906
MID-HIGH RANGE
Motor Hp
5
5
7.5
7.5
7.5
7.5
Motor Nominal Rpm
1745
1745
1745
1745
1745
1745
Maximum Continuous Bhp
5.75
5.75
8.63
8.63
8.63
8.63
Maximum Continuous Watts
4900
4900
7267
7267
7267
7267
Motor Frame Size
S184T
184T
S213T
S213T
S213T
S213T
11 / 8
13/8
13 / 8
13 / 8
13/8
Motor Shaft Diameter (in.)
11 / 8
Fan Rpm Range
897-1139
873-1108
941-1176
941-1176
941-1176
941-1176
Motor Pulley Min. Pitch Diameter (in.)
3.7
3.7
4.8
4.8
4.8
4.8
Motor Pulley Max. Pitch Diameter (in.)
4.7
4.7
6.0
6.0
6.0
6.0
Blower Pulley Pitch Diameter (in.)
7.2
7.4
8.9
8.9
8.9
8.9
Blower Pulley Shaft Diameter (in.)
1.1875
1.1875
1.1875
1.1875
1.1875
1.1875
Blower Pulley Type
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Pulley Center Line Distance (in.)
9.81-13.055
9.81-13.055
9.025-12.179 9.025-12.179 9.025-12.179 9.025-12.179
Belt, Quantity...Type...Length (in.)
1...BX...38
1...BX...38
1...BX...42
1...BX...42
1...BX...42
1...BX...42
Speed Change per Turn Moveable Pulley (Rpm)
40
39
39
39
39
39
Moveable Pulley Maximum Full Turns
6
6
6
6
6
6
Factory Speed Setting (Rpm)
1018
991
1059
1059
1059
1059
HIGH RANGE
Motor Hp
7.5
7.5
10
10
10
10
Motor Nominal Rpm
1745
1745
1745
1745
1745
1745
Maximum Continuous Bhp
8.63
8.63
11.5
11.5
11.5
11.5
Maximum Continuous Watts
7267
7267
9582
9582
9582
9582
Motor Frame Size
S213T
S213T
S215T
S215T
S215T
S215T
13 / 8
13/8
13 / 8
13 / 8
13/8
Motor Shaft Diameter (in.)
13 / 8
Fan Rpm Range
1078-1274
1078-1274
1014-1297
1014-1297
1014-1297
1014-1297
Motor Pulley Min. Pitch Diameter (in.)
5.5
5.5
4.3
4.3
4.3
4.3
Motor Pulley Max. Pitch Diameter (in.)
6.5
6.5
5.5
5.5
5.5
5.5
Blower Pulley Pitch Diameter (in.)
8.9
8.9
7.4
7.4
7.4
7.4
Blower Pulley Shaft Diameter (in.)
1.1875
1.1875
1.1875
1.1875
1.1875
1.1875
Blower Pulley Type
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Pulley Center Line Distance (in.)
9.025-12.179 9.025-12.179 9.025-12.179 9.025-12.179 9.025-12.179 9.025-12.179
Belt, Quantity...Type...Length (in.)
1...BX...42
1...BX...42
2...BX...38
2...BX...38
2...BX...38
2...BX...38
Speed Change per Turn Moveable Pulley (Rpm)
33
33
47
47
47
47
Moveable Pulley Maximum Full Turns
6
6
6
6
6
6
Factory Speed Setting (Rpm)
1176
1176
1156
1156
1156
1156

136

EVAPORATOR FAN DATA 50HJ020-028 HORIZONTAL SUPPLY/RETURN UNITS


020
50HJ

208/230
and 460 v

024
575 v

028
575 v

208/230
and 460 v

575 v

3.7
5
5
5
1725
1745
1745
1745
4.25
5.75
5.75
5.75
3698
4900
4900
4900
56HZ
184T
S184T
184T
7/ 8
11/8
11/8
11 / 8
685-939
751-954
687-873
687-873
2.7
3.7
3.7
3.7
3.7
4.7
4.7
4.7
6.8
8.6
9.4
9.4
1.1875
1.1875
1.1875
1.1875
Fixed
Fixed
Fixed
Fixed
11.293-13.544 9.81-13.055 9.81-13.055 9.81-13.055
1...BX38
1...BX...40
1...BX...41
1...BX...41
42
34
31
31
6
6
6
6
812
853
780
780
5
1745
5.75
4900
S184T
11/8
949-1206
3.7
4.7
6.8
1.1875
Fixed
9.81-13.055
1...BX...38
43
6
1078

5
5
5
1745
1745
1745
5.75
5.75
5.75
4900
4900
4900
184T
S184T
184T
11/8
11/8
11 / 8
949-1206
805-1007
805-1007
3.7
4.8
4.8
4.7
6.0
6.0
6.8
10.4
10.4
1.1875
1.1875
1.1875
Fixed
Fixed
Fixed
9.81-13.055 9.81-13.055 9.81-13.055
1...BX...38
1...BX...45
1...BX...45
43
34
34
6
6
6
1078
906
906

7.5
7.5
7.5
7.5
1745
1745
1745
1745
8.63
8.63
8.63
8.63
7267
7267
7267
7267
S213T
S213T
S213T
S213T
13/8
13/8
13/8
13 / 8
941-1176
941-1176
941-1176
941-1176
4.8
4.8
4.8
4.8
6.0
6.0
6.0
6.0
8.9
8.9
8.9
8.9
1.1875
1.1875
1.1875
1.1875
Fixed
Fixed
Fixed
Fixed
9.025-12.179 9.025-12.179 9.025-12.179 9.025-12.179
1...BX...42
1...BX...42
1...BX...42
1...BX...42
39
39
39
39
6
6
6
6
1059
1059
1059
1059
10
10
10
10
1745
1745
1745
1745
11.5
11.5
11.5
11.5
9582
9582
9582
9582
S215T
S215T
S215T
S215T
13/8
13/8
13/8
13 / 8
1014-1297
1014-1297
1014-1297
1014-1297
4.3
4.3
4.3
4.3
5.5
5.5
5.5
5.5
7.4
7.4
7.4
7.4
1.1875
1.1875
1.1875
1.1875
Fixed
Fixed
Fixed
Fixed
9.025-12.179 9.025-12.179 9.025-12.179 9.025-12.179
2...BX...38
2...BX...38
2...BX...38
2...BX...38
47
47
47
47
6
6
6
6
1156
1156
1156
1156

137

50HJ

LOW RANGE
Motor Hp
N/A
N/A
Motor Nominal Rpm
N/A
N/A
Maximum Continuous Bhp
N/A
N/A
Maximum Continuous Watts
N/A
N/A
Motor Frame Size
N/A
N/A
Motor Shaft Diameter (in.)
N/A
N/A
Fan Rpm Range
N/A
N/A
Motor Pulley Min. Pitch Diameter (in.)
N/A
N/A
Motor Pulley Max. Pitch Diameter (in.)
N/A
N/A
Blower Pulley Pitch Diameter (in.)
N/A
N/A
Blower Pulley Shaft Diameter (in.)
N/A
N/A
Blower Pulley Type
N/A
N/A
Drive Pulley Center Line Distance (in.)
N/A
N/A
Drive Belt, Quantity...Type...Length (in.)
N/A
N/A
Drive Speed Change per Turn Moveable Pulley (Rpm)
N/A
N/A
Drive Moveable Pulley Maximum Full Turns
N/A
N/A
Drive Factory Speed Setting (Rpm)
N/A
N/A
MID-LOW RANGE
Motor Hp
3.7
3
Motor Nominal Rpm
1725
1725
Maximum Continuous Bhp
4.25
3.45
Maximum Continuous Watts
3698
3149
Motor Frame Size
56HZ
56HZ
7/8
7/ 8
Motor Shaft Diameter (in.)
Fan Rpm Range
647-886
810-1072
Motor Pulley Min. Pitch Diameter (in.)
2.7
3.1
Motor Pulley Max. Pitch Diameter (in.)
3.7
4.1
Blower Pulley Pitch Diameter (in.)
7.2
6.6
Blower Pulley Shaft Diameter (in.)
1.1875
1.1875
Blower Pulley Type
Fixed
Fixed
Pulley Center Line Distance (in.)
11.293-13.544 11.286-14.475
Belt, Quantity...Type...Length (in.)
1...BX...38
1...BX...38
Speed Change per Turn Moveable Pulley (Rpm)
40
44
Moveable Pulley Maximum Full Turns
6
6
Factory Speed Setting (Rpm)
767
941
MID-HIGH RANGE
Motor Hp
5
5
Motor Nominal Rpm
1745
1745
Maximum Continuous Bhp
5.75
5.75
Maximum Continuous Watts
4900
4900
Motor Frame Size
S184T
184T
11/8
Motor Shaft Diameter (in.)
11 / 8
Fan Rpm Range
897-1139
873-1108
Motor Pulley Min. Pitch Diameter (in.)
3.7
3.7
Motor Pulley Max. Pitch Diameter (in.)
4.7
4.7
Blower Pulley Pitch Diameter (in.)
7.2
7.4
Blower Pulley Shaft Diameter (in.)
1.1875
1.1875
Blower Pulley Type
Fixed
Fixed
Pulley Center Line Distance (in.)
9.81-13.055 9.81-13.055
Belt, Quantity...Type...Length (in.)
1...BX...38
1...BX...38
Speed Change per Turn Moveable Pulley (Rpm)
40
39
Moveable Pulley Maximum Full Turns
6
6
Factory Speed Setting (Rpm)
1018
991
HIGH RANGE
Motor Hp
7.5
7.5
Motor Nominal Rpm
1745
1745
Maximum Continuous Bhp
8.63
8.63
Maximum Continuous Watts
7267
7267
Motor Frame Size
S213T
S213T
13/8
Motor Shaft Diameter (in.)
13 / 8
Fan Rpm Range
1078-1274
1078-1274
Motor Pulley Min. Pitch Diameter (in.)
5.5
5.5
Motor Pulley Max. Pitch Diameter (in.)
6.5
6.5
Blower Pulley Pitch Diameter (in.)
8.9
8.9
Blower Pulley Shaft Diameter (in.)
1.1875
1.1875
Blower Pulley Type
Fixed
Fixed
Pulley Center Line Distance (in.)
9.025-12.179 9.025-12.179
Belt, Quantity...Type...Length (in.)
1...BX...42
1...BX...42
Speed Change per Turn Moveable Pulley (Rpm)
33
33
Moveable Pulley Maximum Full Turns
6
6
Factory Speed Setting (Rpm)
1176
1176

208/230
and 460 v

Performance data 50HJ (cont)


OPTIONS AND ACCESSORIES 50HJ020-028
(Weight Adders)
OPTION/ACCESSORY WEIGHTS
OPTION/
ACCESSORY
Barometric Relief Damper
Power Exhaust
Economizer
Cu Condenser Coil
Cu Condenser and Evaporator Coils
Electric Heat
Roof Curb (14 inch)
Optional Indoor Motor
Two-Position Damper
Hail Guard
Horizontal Airflow
CO2 Sensor
Return Smoke Detector
Supply Smoke Detector
Non-Fused Disconnect
Non-Powered Convenience Outlet
Enthalpy Sensor
Differential Enthalpy Sensor
Drip Edge
Manual Damper

50HJ

LEGEND
Cu Copper

138

50HJ020
lb
50
125
170
162
316
85
210
28
45
85
90
5
5
5
15
20
2
3
5
25

50HJ028

50HJ024
kg
23
57
77
73
143
39
95
13
20
39
41
2
2
2
7
9
1
1
2
11

lb
50
125
170
162
290
85
210
28
45
85
90
5
5
5
15
20
2
3
5
25

kg
23
57
77
73
132
39
95
13
20
39
41
2
2
2
7
9
1
1
2
11

lb
50
125
195
202
365
85
210
20
45
100
90
5
5
5
15
20
2
3
5
25

kg
23
57
88
92
166
39
95
9
20
45
41
2
2
2
7
9
1
1
2
11

50HJ004
50HJ005
50HJ006
50HJ007

STD UNIT
WEIGHT
Lb
Kg
435
197
445
202
465
211
540
245

ECONOMI$ER IV
WEIGHT
Lb
Kg
50
22.7
50
22.7
50
22.7
50
22.7

50HJ

UNIT

VERT. ECON IV
W/P.E. WEIGHT
Lb
Kg
90
40.9
90
40.9
90
40.9
90
40.9

(A)
CORNER WEIGHT
Lb
Kg
124
56.2
127
57.6
133
60.3
155
70.3

(B)
CORNER WEIGHT
Lb
Kg
106
48.1
108
49.0
113
51.3
132
59.9

(C)
CORNER WEIGHT
Lb
Kg
95
43.1
97
44.0
101
45.8
116
52.6

(D)
CORNER WEIGHT
Lb
Kg
110
49.9
113
51.3
118
53.5
137
62.1
ft-in.
2-95/16
2-95/16
2-95/16
3-55/16

J
mm
846.5
846.5
846.5
1050.0

Base unit dimensions 50HJ004-007

139

140

50HJ008
50HJ009
50HJ012
50HJ014

UNIT

STD UNIT
WEIGHT
Lb
Kg
755
342
895
406
915
415
930
422

ECONOMI$ER IV
WEIGHT
Lb
Kg
75
34.1
75
34.1
75
34.1
75
34.1

50HJ

VERT. ECON IV
W/P.E. WEIGHT
Lb
Kg
145
65.9
145
65.9
145
65.9
145
65.9

(A)
CORNER WEIGHT
Lb
Kg
164
74
195
88
199
90
202
92

(B)
CORNER WEIGHT
Lb
Kg
140
64
166
75
170
77
172
78

(C)
CORNER WEIGHT
Lb
Kg
208
94
247
112
252
114
256
116

(D)
CORNER WEIGHT
Lb
Kg
243
110
288
131
294
134
300
136
H
ft-in.
2- 07/8
2-107/8
2-107/8
1- 27/8

mm
632
885
885
378

J
ft-in.
3-55/16
4-15/16
4-15/16
4-15/16

mm
1050
1253
1253
1253

K
ft-in.
2-911/16
3-03/8
3-03/8
3-03/8

mm
856
924
924
924

Base unit dimensions 50HJ008-014

FRONT

REAR

FRONT

RIGHT
SIDE

RIGHT SIDE

Base unit dimensions COBRA energy


recovery unit 50HJ004-007 with 62AQ060,100

LEFT SIDE

LEFT
SIDE

50HJ
141

50HJ

Base unit dimensions COBRA energy


recovery unit 50HJ004-007 with 62AQ060,100
(cont)

142

Base unit dimensions COBRA energy


recovery unit 50HJ008-014 with 62AQ200,300

50HJ
143

50HJ

Base unit dimensions COBRA energy


recovery unit 50HJ008-014 with 62AQ200,300
(cont)

144

Base unit dimensions 50HJ015,017

50HJ
145

50HJ

Base unit dimensions 50HJ020-028

146

Accessory dimensions 50HJ004-007

50HJ
147

50HJ

Accessory dimensions 50HJ008-014

148

Accessory dimensions 50HJ004-014


COBRA ENERGY RECOVERY UNIT FULL-PERIMETER ROOF CURB 50HJ004-007 WITH 62AQ060,100
DECK PANS

DUCT OPENING SIZES

3 1/4

WATERTIGHT SEAL

R1

Supply = 13 7/8" x 20 1/4"


R1 = 13 5/8" x 17 3/4"
R2 = 13 5/8" x 12 5/16"

DECK PANS

R2
SUPPLY

R1 = Return from building to HVAC


R2 = Return from building to 62AQ

* R2 AIR FROM
"CONTAMINATED" AREAS
SUCH AS PHOTO
PROCESSING LABS, OR
BATHROOM

SIDE VIEW
END VIEW

COBRA ENERGY RECOVERY UNIT FULL-PERIMETER ROOF CURB 50HJ008-014 WITH 62AQ200,300

50HJ
149

Accessory dimensions 50HJ004-014 (cont)


COBRA ENERGY RECOVERY UNIT SUPPLEMENTAL ENERGY RECOVERY SECTION
EQUIPMENT SUPPORT
EQUIPMENT SUPPORT DIMENSIONS (in.)
PART NUMBER
A
B
C
CRAQSUPT001A00
36.9 40 8 to 14
3-6 Ton
CRAQSUPT002A00
36.9 40 14 to 24
CRAQSUPT003A00
49.7
54 8 to 14
71/2-121/2 Ton
CRAQSUPT004A00
49.7 54 14 to 24
UNIT SIZE

4
A

ENERGY
RECOVERY
SECTION

ROOFTOP UNIT
SECTION

SCREW
SUPPORT
IN PLACE
ADJUSTABLE
EQUIPMENT
SUPPORT

50HJ

10 x B (SEE CHART)
PROTECTIVE
RUBBER PAD
(EPDM)

150

PAD
ROOF

UNIT ROOF
CURB

CURB
HEIGHT
1- 2 (305)

2- 0 (610)

2- 0 (610)

CRRFCURB010A00

CRRFCURB011A00

CRRFCURB012A00

50HJ

PKG. NO. REF.


Standard Curb 14 High
Standard Curb for Units
Requiring High Installation
Side Supply and Return
Curb for High Installation

DESCRIPTION

Direction of airflow.

ALL

UNIT

in.

.45

Deg.

.28

.28

Deg.

DIMENSIONS* (degrees and inches)

.43

in.

5. Roof curb: 16 ga. (VA03-56) stl.


6. A 90 degree elbow must be installed on the supply ductwork
below the unit discharge for units equipped with electric heaters.
7. To prevent the hazard of stagnant water build-up in the drain pan of the
indoor section, unit can only be pitched as shown.

4.

NOTES:
1. Roof curb accessory is shipped disassembled.
2. Insulated panels: 1 thick neoprene coated 11/2 lb density.
3. Dimensions in ( ) are in millimeters.

Accessory dimensions 50HJ015,017

151

Accessory dimensions 50HJ015,017 (cont)


HORIZONTAL SUPPLY/RETURN ADAPTER INSTALLATION 50HJ015,017

3 1/2"

2" X 1/4
SUPPORT TYP.
STITCH WELDED

FULLY INSULATED
SUPPLY PLENUM
1" INSULATION
1 1/2 # DENSITY,
STICK PINNED & GLUED

14 3/4"

23"

6"

NOTE: CRRFCURB013A00 is a fully factory preassembled


horizontal adapter and includes an insulated transition duct.
The pressure drop through the adapter curb is negligible.
For horizontal return applications: The power exhaust and
barometric relief dampers must be installed in the return air
duct.

12" WIDE STANDING


SEAM PANELS

ACCESSORY
PACKAGE NO.
CRRFCURB013A00

CURB
HEIGHT
1-11
(584)

50HJ

BAROMETRIC RELIEF/POWER EXHAUST 50HJ015,017

2'-1 5/8"

2'-2 1/16"
1'-6 5/16"

152

DESCRIPTION
Pre-Assembled Horizontal
Adapter Roof Curb

FACTORY-INSTALLED CONVENIENCE OUTLET 50HJ015,017

FACTORY-INSTALLED NON-FUSED DISCONNECT 50HJ015,017

50HJ
153

50HJ

Accessory dimensions 50HJ020-028

154

Selection procedure (with 50HJ006 example)


IV Using the simplified* method below, calculate
the approximate mixed air temperature for
the Small Rooftop (SRT) evaporator coil.
Using the outdoor-air entering cfm, the room cfm
and the room exhaust airflow with their respective
db and wb temperatures, determine the db and wb
entering the rooftop evaporator coil.
a) Estimate the mixed air db to the evaporator coil.
t mix db = ((cfm oa x t oa db) + ((cfm ra cfm
exh) x t ra db)) / ((cfm oa + (cfm ra cfm exh)))
= ((450 cfm x 73.0 F) + ((2000 cfm 450 cfm)
x 78 F)) / ((450 cfm + (2000 cfm 450 cfm)))
Mixed air into the rooftop evaporator coil
= 76.9 F db
b) Estimate the mixed air wb to the evaporator coil.
t mix wb* = ((cfm oa x t oa wb) + ((cfm ra cfm
exh) x t ra wb)) / (cfm oa + (cfm ra cfm exh))
= ((450 cfm x 66.9 F) + ((2000 cfm 450 cfm)
x 65 F)) / ((450 cfm + (2000 cfm 450 cfm)))
Mixed air temperature into the rooftop evaporator = 65.4 F wb
*Simplified method of determining wet bulb (wb)
temperature of mixture. This approximation is
used because the wb lines in the area of the psychrometric chart used in the calculation is relatively
linear, providing a close approximation. A more
accurate solution can be found using the E-Cat
program.
LEGEND
cfm
db
exh
mix
oa
ra
t
wb

cubic feet per minute of air


dry bulb
Energy$Recycler discharge
mixture of outdoor + return air
outside air leaving Energy$Recycler
return air
temperature
wet bulb

V Determine the cooling load requirement for


the rooftop unit.
Customer load is
67,000 Btuh
Less TC supplied by the
Energy$Recycler
13,000 Btuh
Rooftop cooling load required is
54,000 Btuh
VI Select the rooftop unit based on mixed air
entering conditions and cooling load.
Enter cooling capacity table at outdoor entering
temperature 95 F, mixed air entering evaporator at
2000 cfm, 76.9 F db, and 65.4 F wb.
The 50HJ006 will provide a total gross cooling
capacity of 59,420 Btuh and sensible cooling of
43,420 Btuh.
Because these values were not at 80 F entering db,
they were calculated based on the notes following
the Cooling Capacity tables.
NOTE: Unit ratings are gross capacities and do not
include the effect of evaporator-fan motor heat. To
calculate net capacities see Steps VII and VIII.
VII Select net heating capacity of unit to meet
design condition requirements.
Enter the 62AQ060 Heating rating table at
450 cfm. At 70 F and 0 F find the heating value for
the Energy$Recycler to be 15.2 MBtuh. Since the
Energy$Recycler uses room air, the instantaneous
heat is also the Integrated Heat Rating.
The customer heat requirement is 50,000 Btuh.
155

50HJ

I Determine cooling and heating loads at


design conditions.
Given:
Required Cooling Capacity (TC) . . . . .67,000 Btuh
Sensible Heat Capacity (SHC) . . . . . .46,000 Btuh
Required Heating Capacity . . . . . . . .50,000 Btuh
Outdoor Entering-Air Temperature db . . . . . . .95 F
Outdoor Entering-Air Temperature wb . . . . . .75 F
Outdoor-Air Entering Airflow Cfm . . . . . . 450 cfm
Outdoor-Air Winter Design Temperature . . . . . 0 F
Indoor-Air Winter Design Temperature . . . . . .70 F
Air to room including outdoor air . . . . . . 2000 cfm
External Static Pressure . . . . Supply 0.60 in. wg
Return 0.2 in. wg
Indoor-Air Temperature db (room air) . . . . . . .78 F
Indoor-Air Temperature wb (room air) . . . . . . .65 F
Indoor-Air Exhaust Cfm . . . . . . . . . . . . . . 450 cfm
Electrical Characteristics (V-Ph-Hz) . . . . . 230-3-60
Vertical discharge unit with Energy$Recycler unit
required.
II Determine fan speed and power requirements at design conditions.
Before entering the Fan Performance tables, calculate the total static pressure required based on unit
component. From the given and the Accessory Electric Heaters Static Pressure table on page 213 find:
External static pressure supply
0.6 in. wg
External static pressure return
0.2 in. wg
Accessory static electric heater
0.11 in. wg
Total Static
0.9 in. wg
Enter the Fan Performance table for vertical
discharge, 50HJ006 (page 176) at 0.90 in. wg. At
2000 cfm the rpm is 1264 and bhp is 1.44 (interpolation required).
NOTE: Convert bhp to Fan Heat and Watts
using the formula found in the note following the
Evaporator-Fan Motor Efficiency table on page 207.
For this example:
Watts = (746 x Bhp)/(motor efficiency)
Watts = (746 x 1.44)/(0.84) = 1279 watts
Indoor Fan Heat = watts x 3.413 Btuh/watt
= 1279 x 3.413
= 4365 Btuh
III Select Energy$Recycler unit based on Outdoor Entering Cfm.
Entering Energy$Recycler cooling rating table in the
Energy$Recycler Product Data literature at 450 cfm
entering outdoor airflow. Choose Model 62AQ060.
Using 450 cfm outdoor supply airflow, 95 F OD db,
and 75 F OD wb find performance of the
62AQ060 at these conditions:
Energy$Recycler Gross Cooling
Capacity is
13,000 Btuh
Energy$Recycler Gross Sensible
Capacity is
10,090 Btuh
Compressor power is
1.06 kW
Energy$Recycler Leaving db is
73 F
Energy$Recycler Leaving wb is
66.9 F

50HJ

Selection procedure (with 50HJ006 example) (cont)


Fan heat from Step II
4,365 Btuh
Energy$Recycler Heat Capacity
15,200 Btuh
add ER optional supply fan heat
if supplied
+
0 Btuh
Total Unit heat with Energy$Recycler 19,565 Btuh
Determine additional electric heat capacity.
The required heating capacity is 50,000 Btuh.
Therefore, 30,435 Btuh (50,000 19,565) additional heat is required.
Determine additional electric heat in kW.
(30,435/3413 Btuh/kW) = 8.92 kW of heat is
required.
Enter Electric Heating Usage tables, page 216, for
50HJ006 at 208/230, 3 phase. The 10.5 kW
heater at 240 v most closely satisfies the heating
required. To calculate kW at 230 v use the Multiplication Factors table.
10.5 kW x 0.92 = 9.668 kW
10.5 kW x 0.92 x 3413 Btuh/kW = 32,970 Btuh
Total unit net heating capacity is 52,535 Btuh
(32,970 + 19,565).
VIII Determine net cooling capacity.
Cooling capacities are gross capacities and
do not include indoor (evaporator) or optional
Energy$Recycler supply fan heat.
Determine net cooling capacity using the following
formula:
Net Capacity = (Gross Capacity Rooftop Unit +
Energy$Recycler) (IFM Heat + Optional
Energy$Recycler Supply Fan motor heat)
Gross Total Cooling
Rooftop unit
59,420 Btuh
Energy$Recycler
13,000 Btuh
Total
72,420 Btuh
Less
IFM heat (from Step II)
4,365 Btuh
Opt. Energy$Recycler Supply
Fan Motor Heat
none
Net Total Capacity
68,055 Btuh
Gross Sensible Cooling
Rooftop from run
43,400 Btuh
Energy$Recycler
10,090 Btuh
Total
53,490 Btuh
Less
IFM heat (from Step II)
4,365 Btuh
Opt. Energy$Recycler Supply
Fan Motor Heat
none
Net Sensible Capacity
49,125 Btuh
IX Determine the operating watts of the unit.
Cooling with Energy$Recycler in operation:
Rooftop unit:
Compressor watts from cooling
capacity tables . . . . . . . . . . . . . . . . 4,440 watts
Indoor fan motor from Step II. . . . . . 1,279 watts
Outdoor fan motor from Physical Data table find
1/ hp
4
assume OD motor efficiency is 0.75.
Watts = 746 x hp)/(motor Eff)
= (746 x 1/4)/(0.75)
= 249 watts
Dual circuit units will have two indoor and two outdoor fans, double values.
156

b) Energy$Recycler:
Compressor watts from
Energy$Recycler Product Data
literature
1,060 watts
Optional supply fan from
Energy$Recycler Product Data
literature fan curves
none
Exhaust fan, from Energy$Recycler
Product Data literature fan curve
at 450 cfm, 0.2 in. wg Static
110 watts
Total watts for the unit in operation
at design conditions
7,138 watts
X Electrical data RLA, FLA, LRA, MCA and
MOCP.
Separate Power Supply:
If the 62AQ is wired for separate power see the
Electrical Data table.
Single Power Supply with Unit:
The unit is 230 v-3-60 Hz. Look up the 50HJ006
without convenience outlet in the Electrical Data
table and with a 10.5 kW heater, find unit electrical
data. For the rooftop unit the data is MCA =
38.8 amps, MOCP = 40, Min Unit Disconnect Size
FLA = 36, and LRA = 168.
From the Table of X and Y values in the
Energy$Recycler Product Data literature find
230 v, for 62AQ060300, X = 8.1 amps and Y
= 9.3 amps.
Add X amps to the MCA and MOCP and add Y
amps to the minimum disconnect size.
MCA
MOCP
FLA
LRA
SRT
38.8
40
36
168
62AQ
8.1
8.1
9.3
31.7
Total
46.9 amps 48.1** amps 45.3 amps 199.7 amps
**The calculated MOCP is 48.1 amps; it is rounded down to
40 amps. Compare it to MCA; it must be larger than the
MCA of 46.9 amps, so it is rounded up 50 amps.

The wiring of the unit must be suitable for the MCA


calculated above, and the maximum overcurrent
protection (MOCP) device must be selected to meet
the calculated MOCP.
If the overcurrent protective device for the combination load is equal to or less than 60 amps, a single
disconnect may be used for BOTH the main unit
and the 62AQ provided that the wire ampacity supplying the 62AQ is sized for a minimum of 33%
larger than the overcurrent protection device value
(i.e., 60 amps x 0.33 = 20 amps), no further subfusing would be required.
If the overcurrent protection device is greater than
60 amps and the old overcurrent protection device
was less than 60 amps, a FUSED disconnect no
greater than 60 amps must be provided for the
Main Unit and a SEPARATE FUSED disconnect
must be provided for the 62AQ unit.
If the old overcurrent protection device is greater
than 60 amps, a disconnect is required for the
MAIN UNIT as well as a FUSED DISCONNECT for
the 62AQ unit.
In this example a 50-amp disconnect would be
used for the combination load of the 50HJ006
with a 10.5 kW heater and the 62AQ060
Energy$Recycler unit.

Performance data 50HJ


COOLING CAPACITIES, STANDARD UNITS
50HJ004 (3 TONS)
Temp (F)
Air Ent
Condenser
(Edb)

Do not operate at these conditions.


Air Entering Evaporator CFM/BF
900/0.14

1200/0.17

LEGEND

1500/0.20

BF
Edb
Ewb
kW
SHC
TC

Air Entering Evaporator Ewb (F)

Bypass Factor
Entering Dry Bulb
Entering Wet Bulb
Compressor Motor Power Input
Sensible Heat Capacity (1000 Btuh) Gross
Total Capacity (1000 Btuh) Gross

78

72

67

62

78

72

67

62

78

72

67

62

75

TC
SHC
kW

45.6
14.5
2.24

41.9
20.4
2.19

38.7
25.2
2.16

35.7
29.7
2.12

46.8
14.7
2.26

43.5
21.8
2.21

40.8
28.2
2.18

37.7
33.8
2.15

48.1
14.8
2.28

44.8
23.3
2.23

41.8
30.7
2.19

39.0
37.0
2.16

85

TC
SHC
kW

44.4
14.1
2.51

40.7
19.9
2.46

37.5
24.7
2.42

34.5
29.2
2.39

45.7
14.4
2.53

42.1
21.5
2.47

39.3
27.7
2.44

36.4
33.2
2.41

47.0
14.8
2.54

43.5
23.2
2.50

40.4
30.3
2.45

37.6
36.4
2.42

95

TC
SHC
kW

42.9
13.6
2.80

39.3
19.5
2.75

36.1
24.1
2.71

33.1
28.4
2.66

44.6
14.0
2.83

40.8
21.1
2.77

37.8
27.2
2.73

34.9
32.5
2.69

42.0
22.8
2.79

38.9
29.9
2.74

36.1
35.6
2.71

tldb = tedb

105

TC
SHC
kW

41.3
13.0
3.11

37.7
18.8
3.06

34.6
23.5
3.02

31.7
27.8
2.98

39.3
20.7
3.09

36.2
26.6
3.04

33.4
31.8
3.01

40.1
22.1
3.10

37.2
29.3
3.06

34.7
34.7
3.03

tlwb = wet-bulb temperature corresponding to enthalpy of


air leaving indoor coil (hlwb)

115

TC
SHC
kW

36.0
18.3
3.41

33.0
22.9
3.36

29.7
26.7
3.31

37.4
19.9
3.43

34.5
26.1
3.39

31.5
30.9
3.34

38.1
21.3
3.44

35.5
28.7
3.41

33.2
33.2
3.37

125

TC
SHC
kW

34.2
17.6
3.78

31.3
22.2
3.73

27.8
25.8
3.66

35.6
19.4
3.80

32.7
25.4
3.76

29.4
29.4
3.71

36.3
20.8
3.81

33.6
28.0
3.78

31.9
31.8
3.75

NOTES:
1. Direct interpolation is permissible. Do not extrapolate.
2. The following formulas may be used:

hlwb = hewb

sensible heat capacity (Btuh)


1.1 x cfm

total capacity (Btuh)


4.5 x cfm

where hewb = enthalpy of air entering indoor coil


3. The SHC is based on 80 F edb temperature of air entering
evaporator coil.
Below 80 F db, subtract (corr factor x cfm) from SHC.
Above 80 F db, add (corr factor x cfm) to SHC.
Correction Factor = 1.10 x (1 BF) x (db 80)

50HJ005 (4 TONS)
Temp (F)
Air Ent
Condenser
(Edb)

Air Entering Evaporator CFM/BF


1200/0.17

1450/0.19

1600/0.21

2000/0.24

Air Entering Evaporator Ewb (F)


78

72

67

62

78

72

67

62

78

72

67

62

78

72

67

62

75

TC
SHC
kW

58.6
18.3
2.80

54.0
26.1
2.80

50.7
32.7
2.80

44.2
37.5
2.80

59.6
18.7
2.90

55.9
27.6
2.80

52.2
35.1
2.80

47.7
41.8
2.80

59.9
18.7
2.90

56.4
28.2
2.80

52.8
36.2
2.80

49.1
43.8
2.80

61.5
19.2
2.90

58.1
30.2
2.80

54.5
39.5
2.80

50.6
47.5
2.80

85

TC
SHC
kW

56.4
17.6
3.30

52.2
25.4
3.20

48.9
32.0
3.20

41.9
36.4
3.20

57.3
17.9
3.30

54.1
26.9
3.20

50.4
34.5
3.20

45.9
40.8
3.20

58.1
18.2
3.30

54.5
27.5
3.20

51.0
35.7
3.20

47.2
42.8
3.20

59.5
18.5
3.30

55.3
28.6
3.20

52.3
38.5
3.20

48.7
46.6
3.20

95

TC
SHC
kW

54.2
16.9
3.70

50.7
24.9
3.60

46.9
31.1
3.60

39.5
35.0
3.60

55.0
17.2
3.70

51.9
26.1
3.70

48.4
33.6
3.60

43.5
39.6
3.60

56.3
17.6
3.70

52.5
26.8
3.70

48.9
34.7
3.60

45.2
41.8
3.60

57.5
17.8
3.70

53.9
28.8
3.70

50.1
37.5
3.60

46.7
45.6
3.60

105

TC
SHC
kW

52.0
16.2
4.20

48.8
24.3
4.10

44.5
30.2
4.10

36.7
33.6
4.00

52.7
16.5
4.20

49.8
25.3
4.10

46.2
32.8
4.10

40.7
38.2
4.10

53.8
16.8
4.20

50.2
26.0
4.10

46.7
33.9
4.10

42.1
40.3
4.10

54.7
17.1
4.20

51.5
27.9
4.10

48.2
37.4
4.10

44.7
44.4
4.10

115

TC
SHC
kW

49.9
15.5
4.70

46.5
23.4
4.60

41.1
28.9
4.60

34.3
32.4
4.50

50.4
15.8
4.70

47.7
24.9
4.70

43.3
31.8
4.60

37.0
36.3
4.60

41.3
16.0
4.70

48.0
25.4
4.60

44.4
33.4
4.60

38.5
38.3
4.60

51.9
16.3
4.70

48.9
27.1
4.70

45.7
36.9
4.60

42.0
42.0
4.60

125

TC
SHC
kW

47.5
15.0
5.20

43.8
22.5
5.20

37.5
27.4
5.10

32.4
31.5
5.10

45.1
24.1
5.20

39.0
30.2
5.20

33.8
33.7
5.10

45.3
24.7
5.20

40.1
31.9
5.20

35.4
35.4
5.10

46.3
26.5
5.20

42.6
35.9
5.20

38.8
38.8
5.20

50HJ006 (5 TONS)
Temp (F)
Air Ent
Condenser
(Edb)

Air Entering Evaporator CFM/BF


1500/0.08

1750/0.09

2000/0.11

2500/0.13

Air Entering Evaporator Ewb (F)


78

72

67

62

78

72

67

62

78

72

67

62

72

67

62

75

TC
SHC
kW

80.4
25.6
3.65

70.8
34.1
3.53

65.4
42.7
3.49

58.5
49.9
3.44

82.5
26.1
3.68

72.5
35.7
3.55

67.3
45.5
3.50

61.1
54.2
3.46

83.7
26.3
3.70

73.0
36.8
3.55

68.4
48.0
3.51

62.8
57.8
3.47

78

74.8
39.6
3.57

70.3
53.0
3.54

64.8
63.4
3.48

85

TC
SHC
kW

78.5
25.1
4.20

68.9
33.5
3.98

63.2
41.8
3.94

55.3
48.4
3.87

70.5
35.0
4.00

65.1
44.8
3.96

57.9
52.8
3.90

72.2
37.0
4.03

66.4
47.6
3.97

60.2
56.8
3.92

73.2
39.3
4.04

68.1
52.5
3.99

62.9
62.4
3.94

95

TC
SHC
kW

66.8
32.8
4.48

60.6
40.7
4.43

52.4
47.0
4.35

68.3
34.5
4.50

62.5
43.8
4.45

54.3
51.1
4.37

69.3
36.0
4.51

63.8
46.7
4.46

56.6
55.0
4.40

71.2
39.1
4.55

65.6
51.8
4.48

60.6
60.5
4.44

105

TC
SHC
kW

64.3
32.0
5.03

57.7
39.6
4.96

49.9
45.8
4.87

65.9
33.7
5.05

59.8
42.8
4.99

51.7
49.7
4.90

66.9
35.3
5.06

61.1
45.7
5.00

54.1
53.5
4.93

68.4
38.4
5.08

62.8
51.0
5.02

58.4
58.4
4.98

115

TC
SHC
kW

61.5
31.0
5.61

54.8
38.4
5.55

47.3
44.5
5.46

62.8
32.5
5.62

56.7
41.6
5.58

49.1
48.2
5.49

64.0
34.4
5.65

58.2
44.6
5.60

51.6
51.6
5.52

65.4
37.4
5.67

59.9
50.0
5.61

56.1
56.1
5.57

125

TC
SHC
kW

58.7
30.0
6.27

51.6
37.2
6.19

44.5
43.1
6.09

59.9
31.7
6.28

53.4
40.4
6.21

46.2
46.2
6.13

60.8
33.3
6.29

54.9
43.4
6.24

49.0
48.9
6.17

62.2
36.4
6.31

56.8
48.9
6.27

53.5
53.4
6.22

50HJ007 (6 TONS)
Air Entering Evaporator CFM/BF
1800/0.05

2100/0.06

2400/0.06

3000/0.08

50HJ

Temp (F)
Air Ent
Condenser
(Edb)

Air Entering Evaporator Ewb (F)


78

72

67

62

78

72

67

62

78

72

67

62

72

67

62

75

TC
SHC
kW

93.5
29.9
4.73

86.7
43.0
4.58

80.7
53.7
4.46

74.4
63.8
4.33

95.3
30.1
4.77

88.8
45.0
4.63

82.7
57.4
4.50

76.6
68.9
4.38

97.3
30.7
4.82

90.5
47.2
4.67

84.4
61.2
4.55

78.2
73.6
4.41

78

92.6
51.2
4.72

86.3
67.4
4.58

81.0
80.7
4.47

85

TC
SHC
kW

91.3
29.2
5.29

84.1
42.0
5.10

78.2
52.6
4.97

72.0
62.7
4.85

93.0
29.6
5.34

86.4
44.5
5.16

80.3
56.6
5.03

74.1
68.0
4.90

88.2
46.8
5.21

81.7
60.2
5.06

75.7
72.5
4.93

90.2
50.6
5.26

84.0
67.4
5.12

78.8
78.7
4.99

95

TC
SHC
kW

89.0
28.4
5.85

81.3
41.0
5.65

75.3
51.4
5.52

69.2
61.4
5.39

83.4
43.4
5.71

77.3
55.3
5.57

71.3
66.6
5.44

85.1
45.8
5.77

78.9
59.2
5.62

72.9
71.2
5.48

87.2
50.2
5.83

80.6
65.8
5.66

76.2
76.2
5.55

105

TC
SHC
kW

77.9
39.7
6.22

72.0
50.2
6.08

66.1
60.0
5.94

80.0
42.2
6.29

73.8
54.0
6.13

68.0
65.2
6.00

81.6
44.6
6.34

75.3
57.8
6.17

69.6
69.3
6.04

83.4
49.0
6.40

77.1
64.5
6.22

73.2
73.2
6.12

115

TC
SHC
kW

74.7
38.7
6.84

68.4
48.8
6.68

61.8
58.1
6.49

75.9
40.8
6.87

70.0
52.6
6.71

64.1
63.2
6.56

77.6
43.3
6.93

71.3
56.4
6.75

66.5
66.4
6.63

78.7
46.9
6.96

73.0
63.2
6.80

70.1
70.0
6.72

125

TC
SHC
kW

70.3
37.2
7.43

63.6
47.0
7.25

57.2
55.8
7.03

71.8
39.5
7.48

65.5
51.0
7.30

59.1
59.1
7.13

72.9
41.7
7.51

66.8
55.0
7.35

61.9
61.9
7.22

74.0
45.4
7.54

68.6
61.8
7.41

66.4
66.3
7.33

157

Performance data 50HJ (cont)


COOLING CAPACITIES, STANDARD UNITS (cont)
50HJ008 (71/2 TONS)
Temp (F)
Air Ent
Condenser
(Edb)

Do not operate at these conditions.


Air Entering Evaporator CFM/BF
2250/0.095

3000/0.110

LEGEND

3750/0.135

BF
Edb
Ewb
kW
SHC
TC

Air Entering Evaporator Ewb (F)

Bypass Factor
Entering Dry Bulb
Entering Wet Bulb
Compressor Motor Power Input
Sensible Heat Capacity (1000 Btuh) Gross
Total Capacity (1000 Btuh) Gross

78

72

67

62

78

72

67

62

78

72

67

62

75

TC
SHC
kW

111.9
35.4
5.15

105.5
50.6
5.15

96.9
63.6
5.07

87.6
75.7
5.04

113.3
35.9
5.42

107.3
53.3
5.16

99.6
69.2
5.11

90.7
83.7
5.06

114.7
38.8
5.68

110.3
58.0
5.20

101.9
76.6
5.13

93.8
92.2
5.07

85

TC
SHC
kw

108.8
34.4
5.86

102.5
49.7
5.86

93.6
62.4
5.79

83.6
73.9
5.73

111.9
35.3
6.15

105.1
52.8
5.89

96.5
68.4
5.82

87.5
82.2
5.77

114.1
35.7
6.43

107.7
57.3
5.93

99.0
75.9
5.86

90.6
90.0
5.78

95

TC
SHC
kW

107.4
34.0
6.69

98.9
48.5
6.65

90.1
61.2
6.58

79.3
71.9
6.49

109.3
34.3
6.94

101.6
51.9
6.69

92.9
67.2
6.61

83.5
80.2
6.53

110.8
34.9
7.21

103.8
56.2
6.72

95.3
74.9
6.64

87.4
87.3
6.57

tldb = tedb

105

TC
SHC
kW

103.4
32.6
7.52

95.3
47.3
7.51

86.2
59.6
7.44

75.7
70.2
7.31

97.6
50.7
7.55

88.8
65.9
7.48

79.6
78.0
7.36

100.0
55.3
7.59

91.0
73.6
7.50

84.1
84.1
7.41

tlwb = wet-bulb temperature corresponding to enthalpy of


air leaving indoor coil (hlwb)

115

TC
SHC
kW

91.0
45.9
8.43

82.0
58.0
8.33

71.6
68.1
8.20

93.2
49.3
8.46

84.5
64.2
8.37

75.4
75.3
8.27

95.6
54.2
8.52

86.6
72.1
8.42

80.7
80.7
8.34

125

TC
SHC
kW

86.2
44.1
9.38

77.8
56.4
9.29

68.1
66.3
9.14

88.3
47.5
9.43

80.0
62.6
9.34

71.9
71.8
9.24

90.0
52.1
9.47

81.9
70.1
9.38

77.2
77.2
9.32

NOTES:
1. Direct interpolation is permissible. Do not extrapolate.
2. The following formulas may be used:

hlwb = hewb

Temp (F)
Air Ent
Condenser
(Edb)

Air Entering Evaporator CFM/BF


2550/0.11

3000/0.12

3400/0.13

4250/0.17

Air Entering Evaporator Ewb (F)


57

62

67

72

57

62

67

72

57

62

67

72

57

62

67

72

75

TC
SHC
kW

94.6
94.6
5.72

101.0 110.0 119.2 100.4


84.4
69.4
54.4 100.4
5.76
5.76
5.82
5.74

104.4 113.4 121.8 104.2 106.8 115.8


92.4
75.0
57.2 104.2
99.0
80.0
5.76
5.80
5.86
5.74
5.76
5.82

123.4 109.8 111.0 119.0 125.8


59.8 109.8 110.4
89.4
64.2
5.88
5.76
5.78
5.84
5.90

85

TC
SHC
kW

91.0
91.0
6.46

97.4
83.0
6.50

106.8 115.8
68.8
53.2
6.52
6.58

97.4
97.4
6.50

101.0 110.0 119.6 101.2 103.0 112.0


91.2
74.2
57.0 101.2
97.6
78.8
6.52
6.54
6.60
6.5
6.52
6.54

121.6 108.0 108.0 116.0 123.4


59.6 108.0 108.0
89.4
64.2
6.64
6.54
6.54
6.60
6.64

95

TC
SHC
kW

85.2
85.2
7.24

91.4
80.4
7.28

103.0 112.8
67.2
52.6
7.36
7.42

93.4
93.4
7.30

96.6
89.4
7.32

106.2 116.0
73.0
55.8
7.38
7.44

98.2
98.2
7.34

99.2
96.2
7.36

108.4
78.2
7.40

117.8 104.6 104.6 111.6 121.2


58.8 104.6 104.6
88.0
64.6
7.46
7.36
7.36
7.42
7.50

105

TC
SHC
kW

80.0
80.0
8.08

82.2
76.6
8.12

98.6
65.6
8.26

108.6
51.2
8.32

87.0
87.0
8.16

87.8
85.6
8.16

101.6 111.8
71.6
54.8
8.28
8.36

93.4
93.4
8.20

93.6
93.2
8.20

103.8
76.6
8.30

114.0 101.0 100.8 106.8 116.6


57.8 101.0 100.8
86.8
63.6
8.38
8.28
8.28
8.30
8.40

115

TC
SHC
kW

73.6
73.6
9.00

74.6
73.0
9.00

89.4
62.2
9.16

103.4
49.6
9.28

81.0
81.0
9.08

81.2
81.2
9.08

95.2
69.4
9.22

86.2
86.2
9.14

86.2
86.2
9.14

98.4
75.0
9.26

108.4
56.4
9.34

125

TC
SHC
kW

68.6
68.6
9.98

68.6
68.6
9.98

80.2
98.2
74.4
59.0
48.0
74.4
10.14 10.32 10.06

106.4
53.0
9.30

74.4
84.0 101.0 79.2
79.2
86.8
74.4
65.4
51.6 79.2
79.2
71.0
10.06 10.18 10.36 10.14 10.14 10.22

96.4
96.4
9.22

96.4
96.4
9.22

101.6 111.8
85.4
62.8
9.30
9.38

102.8 88.0
88.0
93.8 105.6
54.6 88.0
88.0
82.8
61.0
10.38 10.24 10.24 10.28 10.42

50HJ012 (10 TONS)


Temp (F)
Air Ent
Condenser
(Edb)

Air Entering Evaporator CFM/BF


3000/0.31

3200/0.34

4000/0.46

5000/0.61

Air Entering Evaporator Ewb (F)


78

72

67

62

78

72

67

62

78

72

67

62

78

72

67

62

75

TC
SHC
kW

152.7 140.3 129.4 115.0 153.1


46.7
65.6
82.2
97.4
47.3
7.34
7.35
7.21
7.12
7.54

141.2 130.4 118.1 154.9 145.2 134.0


66.7
84.4 101.5
49.8
71.3
93.1
7.37
7.23
7.13
7.71
7.46
7.31

122.1 158.1 147.5 136.6 125.3


113.5
51.0
77.9 103.7 124.7
7.17
8.10
7.51
7.37
7.22

85

TC
SHC
kW

150.5 137.7 125.3 110.0 151.5


44.7
65.0
81.2
95.2
44.9
8.28
8.29
8.13
8.02
8.51

138.9 126.6 113.6


66.3
83.6
99.7
8.32
8.16
8.03

142.6 130.6
71.0
92.8
8.40
8.24

117.7
112.0
8.09

144.6 133.3 122.3


76.9 103.1 122.2
8.45
8.31
8.16

95

TC
SHC
kW

147.7 133.8 120.7 103.0


43.9
63.9
79.6
92.2
9.33
9.33
9.16
8.98

135.1 121.9 107.2


65.2
82.0
97.0
9.35
9.18
9.00

138.8 125.8
70.6
91.5
9.44
9.27

112.8
109.7
9.07

141.7 128.5 118.5


76.9 102.5 118.4
9.51
9.33
9.19

105

TC
SHC
kW

128.7 115.4 96.5


62.3
77.6 89.4
10.46 10.28 10.00

129.8 116.6 99.7


63.6
80.2 93.5
10.47 10.30 10.07

133.7 120.3
69.4
89.6
10.57 10.38

107.1
106.8
10.21

136.7 122.8 114.5


76.0 100.6 114.3
10.66 10.43 10.31

115

TC
SHC
kW

123.2 109.1 90.8


60.4
75.1 86.6
11.66 11.47 11.20

124.3 110.3 92.2


61.9
77.8 90.0
11.68 11.51 11.25

127.9 114.4
67.6
87.6
11.77 11.60

100.8
100.7
11.41

130.9 116.8 110.1


74.6
98.7 109.9
11.89 11.66 11.58

125

TC
SHC
kW

117.5 101.8 86.2


58.5
72.5 84.5
12.99 12.77 12.50

118.5 103.0 87.4


60.0
75.0 87.3
13.02 12.81 12.55

121.6 107.1
65.8
85.1
13.10 12.92

96.0
96.0
12.74

124.1 110.3 104.8


72.5
96.9 104.8
13.19 13.01 12.91

50HJ014 (121/2 TONS)


Temp (F)
Air Ent
Condenser
(Edb)

Air Entering Evaporator CFM/BF


3750/0.08

4300/0.09

5000/0.11

6250/0.13

Air Entering Evaporator Ewb (F)


72

67

62

72

67

62

72

67

62

72

67

62

75

TC
SHC
kW

167.1
82.5
9.44

154.3
103.5
9.18

142.0
123.6
8.95

169.8
85.8
9.50

157.7
109.7
9.26

144.8
132.0
9.01

173.5
90.3
9.60

160.6
117.7
9.33

148.4
141.9
9.07

176.5
98.2
9.68

164.5
130.7
9.43

153.3
153.1
9.17

85

TC
SHC
kW

162.3
80.9
10.49

149.3
101.4
10.18

135.6
120.9
9.97

165.1
84.4
10.55

152.5
107.9
10.27

139.6
129.9
10.02

168.8
89.6
10.67

155.3
115.8
10.32

143.5
139.8
10.11

172.1
97.6
10.75

159.2
129.3
10.43

149.3
149.1
10.21

95

TC
SHC
kW

156.5
79.1
11.60

143.7
99.5
11.30

126.3
116.5
11.01

159.6
83.0
11.69

146.8
106.1
11.39

131.3
126.0
11.10

162.3
87.6
11.75

149.8
114.2
11.47

136.5
135.8
11.20

166.5
95.8
11.87

153.2
127.7
11.56

144.5
144.4
11.35

105

TC
SHC
kW

150.0
76.5
12.76

136.2
96.7
12.42

115.7
111.2
12.09

153.0
80.8
12.83

139.3
103.5
12.52

120.9
120.0
12.20

155.6
85.7
12.91

142.5
112.3
12.62

128.5
128.4
12.32

158.8
93.6
12.96

145.9
125.9
12.72

138.8
138.7
12.52

115

TC
SHC
kW

141.8
73.6
13.85

122.2
91.2
13.55

104.4
104.2
13.22

144.3
77.9
13.94

126.1
98.5
13.64

110.8
110.8
13.35

147.7
83.4
14.05

129.4
107.3
13.73

118.9
118.4
13.50

150.7
91.8
14.14

135.2
121.9
13.86

130.1
129.9
13.70

125

TC
SHC
kW

132.5
70.9
15.04

108.6
85.7
14.66

93.9
93.8
14.44

134.8
74.9
15.14

111.4
92.9
14.75

100.7
100.7
14.55

137.6
80.2
15.23

114.4
101.4
14.85

106.6
106.5
14.72

140.3
89.0
15.29

122.9
116.3
14.94

120.1
120.1
14.84

158

sensible heat capacity (Btuh)


1.1 x cfm

total capacity (Btuh)


4.5 x cfm

where hewb = enthalpy of air entering indoor coil


3. The SHC is based on 80 F edb temperature of air entering
evaporator coil.
Below 80 F db, subtract (corr factor x cfm) from SHC.
Above 80 F db, add (corr factor x cfm) to SHC.
Correction Factor = 1.10 x (1 BF) x (db 80)

50HJ009 (81/2 TONS)

50HJ

COOLING CAPACITIES STANDARD UNITS (cont)


50HJ015 (12 Tons)
Temp (F)
Air Ent
Condenser
(Edb)
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW

60
70
75
85
95
105
115
125

3600/0.01
54
152
152
7.56
148
148
8.5
146
146
9.02
142
142
10.1
138
138
11.4
134
134
12.7
129
129
14.2
124
124
15.8

58
156
144
7.65
152
141
8.58
150
139
9.1
145
136
10.2
141
133
11.4
136
129
12.8
130
125
14.2
125
121
15.8

62
161
135
7.74
156
133
8.67
154
132
9.18
149
129
10.3
143
127
11.5
138
124
12.8
132
121
14.3
126
118
15.9

67
174
114
8.01
169
112
8.97
166
111
9.45
161
109
10.6
155
106
11.8
149
104
13.2
143
101
14.6
136
98.2
16.2

72
189
92.9
8.33
183
90.6
9.26
181
89.7
9.8
175
87.4
10.9
168
85
12.2
162
82.4
13.5
155
79.8
15
147
77
16.6

76
201
75.4
8.6
195
73.2
9.53
192
72.2
10.1
186
70
11.2
179
67.7
12.4
172
65.3
13.8
164
62.7
15.3
156
60.1
17

80
213
57.5
8.86
206
55.4
9.8
204
54.6
10.4
196
52.4
11.5
189
50.1
12.7
181
47.7
14.1
172
45.1
15.6
163
42.5
17.2

54
161
161
7.76
157
157
8.7
155
155
9.22
151
151
10.3
147
147
11.6
141
141
12.9
136
136
14.4
131
131
16.1

Air Entering Evaporator Cfm/BF


4375/0.01
Air Entering Evaporator Ewb (F)
58
62
67
72
76
164
167
180
195
207
156
150
125 99.6 78.7
7.82 7.88 8.14 8.46 8.72
160
162
174
189
200
153
148
123 97.3 76.5
8.75 8.81 9.07 9.39 9.66
158
160
172
186
197
151
146
122 96.2 75.5
9.27 9.31 9.58 9.91 10.2
153
154
166
179
190
147
144
119 93.9 73.2
10.4 10.4 10.7
11
11.3
148
149
160
173
183
144
141
117 91.6 70.9
11.6 11.6 11.9 12.3 12.6
142
143
153
166
176
139
137
114
89
68.4
13
13 13.3 13.6 13.9
137
138
146
158
168
135
133
111 86.3 65.9
14.4 14.5 14.7 15.1 15.5
131
132
140
150
159
130
128
109 83.5 63.2
16.1 16.1 16.4 16.7 17.1

5000/0.01
80
218
57.5
8.97
211
55.3
9.91
208
54.6
10.5
200
52.3
11.6
192
50
12.8
184
47.5
14.2
175
45
15.7
165
42.5
17.3

54
169
169
7.92
165
165
8.86
163
163
9.39
158
158
10.5
153
153
11.8
148
148
13.1
142
142
14.6
136
136
16.3

58
171
166
7.95
166
162
8.89
164
161
9.41
159
157
10.5
153
153
11.8
148
148
13.1
142
142
14.6
136
136
16.2

62
172
162
7.98
167
160
8.91
164
158
9.43
159
155
10.5
154
152
11.8
148
148
13.1
142
142
14.6
136
136
16.2

67
184
134
8.24
179
132
9.16
176
131
9.68
170
128
10.8
164
126
12
157
123
13.4
149
120
14.8
142
117
16.4

72
199
105
8.55
193
103
9.49
189
101
9.99
183
99.1
11.1
177
96.9
12.4
169
94.3
13.7
161
91.6
15.2
153
88.7
16.8

76
211
81.3
8.82
204
79.1
9.76
201
78.1
10.3
194
75.8
11.4
187
73.5
12.7
179
70.9
14
171
68.4
15.6
162
65.7
17.2

80
222
57.4
9.06
214
55.3
9.99
212
54.5
10.6
203
52.2
11.7
195
49.9
12.9
186
47.4
14.3
177
45
15.7
167
42.4
17.4

50HJ015 (12 Tons) (cont)


Temp (F)
Air Ent
Condenser
(Edb)
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW

60
70
75
85
95
105
115
125

54
175
175
8.03
170
170
8.98
168
168
9.5
163
163
10.6
158
158
11.9
152
152
13.2
146
146
14.7
140
140
16.4

58
175
173
8.05
171
169
8.99
168
167
9.51
163
162
10.6
158
157
11.9
152
152
13.2
146
146
14.7
140
140
16.4

62
176
171
8.07
171
168
9.01
169
166
9.52
164
162
10.6
158
157
11.9
152
152
13.2
146
146
14.7
140
140
16.4

67
187
142
8.3
181
140
9.23
179
139
9.75
172
136
10.9
166
134
12.1
159
131
13.4
151
128
14.9
144
125
16.5

6250/0.02
Air Entering Evaporator Ewb (F)
72
76
80
54
58
62
202
214
224
180
180
180
110 83.8 57.3 180
180
180
8.61 8.87
9.1
8.14 8.15 8.16
195
207
216
175
176
176
108 81.5 55.2 175
176
176
9.55 9.81
10
9.09
9.1
9.11
192
203
213
173
173
173
107 80.5 54.4 173
173
173
10.1 10.3 10.6 9.62 9.62 9.62
185
196
205
168
168
168
104 78.2 52.2 168
168
168
11.2 11.5 11.7 10.7 10.7 10.8
178
189
196
162
162
162
102 75.9 49.8 162
162
162
12.4 12.7 12.9
12
12
12
171
181
187
157
157
157
99.3 73.3 47.4 157
157
157
13.8 14.1 14.3 13.4 13.4 13.4
163
172
177
150
150
150
96.6 70.7 44.9 150
150
150
15.3 15.6 15.8 14.9 14.9 14.9
155
163
167
144
144
144
93.7 67.9 42.4 144
144
144
16.9 17.2 17.4 16.5 16.5 16.5

LEGEND
Bypass Factor
Entering Dry-Bulb
Entering Wet-Bulb
Compressor Motor Power Input
Leaving Dry-Bulb
Leaving Wet-Bulb
Sensible Heat Capacity (1000 Btuh) Gross
Total Capacity (1000 Btuh) Gross

NOTES:
1. Direct interpolation is permissible. Do not extrapolate.
2. The following formulas may be used:
sensible capacity (Btuh)
tldb = tedb
1.10 x cfm
tlwb = Wet-bulb temperature corresponding to enthalpy of air leaving evaporator coil (hlwb)
total capacity (Btuh)
hlwb = hewb
4.5 x cfm
Where: hewb = Enthalpy of air entering evaporator coil
3. The SHC is based on 80 F edb temperature of air entering evaporator coil.
Below 80 F edb, subtract (corr factor x cfm) from SHC.
Above 80 F edb, add (corr factor x cfm) to SHC.

67
190
151
8.36
184
148
9.3
181
147
9.81
175
145
10.9
168
142
12.1
161
139
13.5
153
136
14.9
146
133
16.6

72
204
115
8.66
198
113
9.61
195
112
10.1
188
109
11.2
180
107
12.5
173
104
13.9
165
102
15.4
156
98.7
17

76
216
86.2
8.93
209
84
9.87
206
83
10.4
198
80.6
11.5
190
78.3
12.8
182
75.7
14.2
174
73.1
15.7
164
70.2
17.3

80
226
57.2
9.14
218
55.1
10.1
215
54.3
10.6
206
52.1
11.8
197
49.7
13
188
47.4
14.4
178
44.8
15.8
168
42.3
17.4

BYPASS
FACTOR
(BF)

79
81

.05
.10
.20
.30

1.04
.98
.87
.76

ENTERING AIR DRY-BULB TEMP (F)


78
77
76
75
under 75
82
83
84
85
over 85
Correction Factor
2.07 3.11 4.14 5.18
1.96 2.94 3.92 4.90
Use formula
1.74 2.62 3.49 4.36
shown below.
1.53 2.29 3.05 3.82

Interpolation is permissible.
Correction Factor = 1.10 x (1 BF) x (edb 80).
4. Use chart below for bypass factor.

CFM

54

58

3600
4375
5000
5625
6250

0.355
0.439
0.486
0.525
0.551

0.158
0.255
0.314
0.360
0.410

ENTERING WET-BULB (F)


62
67
72
Bypass Factor
0.054
0.038
0.049
0.112
0.043
0.057
0.126
0.054
0.037
0.174
0.066
0.073
0.202
0.080
0.079

76

80

0.000
0.000
0.000
0.000
0.000

0.000
0.000
0.000
0.000
0.000

159

50HJ

BF
Edb
Ewb
kW
ldb
lwb
SHC
TC

Air Entering Evaporator Cfm/BF


5625/0.02

Performance data 50HJ (cont)


COOLING CAPACITIES STANDARD UNITS (cont)
50HJ017 (15 Tons)
Temp (F)
Air Ent
Condenser
(Edb)
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW

60
70
75
85
95
105
115
125

4500/0.01
54
180.5
180.5
9.41
176.7
176.7
10.5
174.7
174.7
11.07
169.6
169.6
12.29
164.3
164.3
13.59
158.1
158.1
14.97
151.8
151.8
16.45
144.7
144.7
17.96

58
184.6
172.4
9.49
180.5
169
10.57
177.5
167.2
11.14
172.2
163.3
12.35
166.5
158.9
13.65
159.8
154.2
15.02
152.8
149.1
16.48
145.4
143.5
18.01

62
188.7
159.4
9.58
184.4
155.8
10.64
181
147
11.2
175
145
12.3
168
142
13.5
161
138
14.8
152
134
16.1
146
123.4
18.05

67
203.5
132.3
9.87
199
129.4
10.96
196
124
11.6
190
121
12.7
182
118
13.9
174
115
15.2
165
111
16.5
157.1
102.2
18.49

72
219.9
104.7
10.19
215.1
102.4
11.35
213
99
12
205
97
13.1
197
93
14.3
188
91
15.6
179
87
16.9
170.5
81.16
18.99

76
233.7
87.9
10.47
227.8
86
11.62
224.2
84.9
12.23
218.1
82.5
13.5
209.8
79.8
14.85
200.3
76.8
16.28
190.6
73.7
17.79
180.7
70.4
19.44

80
247
65.7
10.78
242
63.9
11.95
238
62.9
12.57
230.8
60.7
13.86
221.2
57.9
15.23
212.4
55.2
16.69
201.3
52.1
18.21
191.1
48.9
19.85

54
189.3
189.3
9.58
185.3
185.3
10.68
182.3
182.3
11.25
177.2
177.2
12.47
171.7
171.7
13.8
165.2
165.2
15.19
158.4
158.4
16.68
150.8
150.8
18.18

Air Entering Evaporator Cfm/BF


5250/0.01
Air Entering Evaporator Ewb (F)
58
62
67
72
76
191.7 194.2 208.7 224.1 238
183.2 173.2 142.8 110.4
91
9.63 9.68 9.97 10.29 10.57
187.5 189.8 203 219.2 231.8
179.7 169.3 138.9 108
89.1
10.72 10.76 11.06 11.45 11.72
184.4 186
201
217 229.2
177.9 160
133
105
88
11.3 11.3 11.7 12.1 12.33
179
180
194
209 221.9
174.1 157
130
102
85.6
12.51 12.5 12.8 13.2 13.61
172.6 172
187
201 213.4
168.8 154
127
98
82.8
13.82 13.6
14
14.4 14.96
166
165
178
191 203.8
163.1 150
124
95
79.9
15.21 14.9 15.3 15.7 16.39
158.8 157
168
180
194
157
145
120
91 76.7
16.68 16.2 16.6
17 17.91
151.1 151.5 160.2 172.9 183.9
150.2 135.2 109.6 85.15 73.4
18.22 18.25 18.6 19.11 19.5

6000/0.01
80
251
65.5
10.87
245
63.8
12.04
242
62.8
12.66
233.3
60.5
13.96
224.6
57.9
15.32
214.6
55.1
16.77
204.5
52.1
18.3
192
48.8
19.89

54
198.1
198.1
9.75
193
193
10.85
190.9
190.9
11.45
185.6
185.6
12.67
179.1
179.1
14
172.3
172.3
15.41
165
165
16.89
156.8
156.8
18.42

58
198.8
195.1
9.77
194.5
191.4
10.87
191.3
189.5
11.45
185.9
184.7
12.68
179.3
178.7
14
172.3
172.2
15.4
164.9
164.9
16.88
156.9
156.9
18.44

62
199.6
185.1
9.79
195.1
181
10.89
189
173
11.4
183
168
12.6
176
164
13.8
169
158
15.1
161
151
16.4
157
145.6
18.46

67
212.9
153.1
10.07
208.1
149.7
11.17
204
143
11.8
198
139
12.9
190
136
14.1
181
132
15.4
171
128
16.7
163.2
117.4
18.72

72
229.3
116.7
10.39
224.3
114.2
11.55
219
113
12.1
212
106
13.3
203
102
14.5
193
98
15.7
181
94
17
175.4
89.3
19.14

76
242
94
10.67
237
92.2
11.82
233.1
91
12.44
225.7
88.6
13.71
217.1
86
15.07
207.3
83
16.5
197.3
79.8
18.01
186.2
76.4
19.65

80
255
65.4
10.95
248
63.7
12.13
246
62.7
12.75
237
60.4
14.05
228
57.8
15.43
216.8
54.9
16.86
206.6
51.9
18.39
193.9
48.7
19.93

50HJ017 (15 Tons) (cont)


Temp (F)
Air Ent
Condenser
(Edb)
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW

60
70
75
85
95
105
115

50HJ

125

BF
Edb
Ewb
kW
ldb
lwb
SHC
TC

Air Entering Evaporator Cfm/BF


6750/0.01
54
203.8
203.8
9.88
199.6
199.6
10.99
196.4
196.4
11.58
191
191
12.81
184.4
184.4
14.15
176.7
176.7
15.55
169.5
169.5
17.05
160.9
160.9
18.57

58
204.2
201.8
9.88
199.8
197.8
10.99
196.6
195.7
11.58
191.1
190.5
12.81
184.5
184.2
14.15
176.7
176.7
15.55
169.4
169.4
17.04
161.1
161.1
18.59

62
204.6
191.2
9.89
200.1
187
11
194
181
11.6
188
175
12.7
181
170
13.9
173
162
15.2
166
155
16.6
161.2
150.7
18.62

67
216.3
164.1
10.13
210.5
159.7
11.24
206
153
11.9
200
148
13
192
144
14.2
182
140
15.5
172
136
16.8
165.6
125.6
18.81

7500/0.02
Air Entering Evaporator Ewb (F)
72
76
80
54
58
62
67
72
231.7 244
257 209.5 209.5 209.6 218.8 235
124.1
97 65.4 209.5 209.5 196.6 173.7 138.1
10.45 10.72 11
9.99 9.99 9.99 10.19 10.51
226.5 239
250 205.2 205.1 205.1 213.8 228.8
121.3 95.2 63.5 205.2 205.1 192.4 169.8 134.5
11.6 11.88 12.18 11.12 11.11 11.11 11.31 11.65
220
235
247 201.9 201.9 198
208
223
120
94 62.5 201.9 201.9 186
163
163
12.2 12.5 12.8 11.71 11.7 11.7 11.9 11.9
213 227.8 239 196.4 196.4 192
202
214
115
91.6 60.2 196.4 196.4 180
157
119
13.3 13.77 14.1 12.96 12.95 12.8 13.1 13.4
205 219.1 229.7 189.7 189.7 185
194
206
108
88.9 57.7 189.7 189.7 174
153
113
14.6 15.14 15.47 14.29 14.29
14 14.3 14.6
194 209.2 218.5 181.9 181.9 177
184
194
103
86
54.9 181.9 181.9 166
148
107
15.8 16.57 16.9 15.7 15.7 15.3 15.5 15.8
183 198.2 207.1 173.9 173.8 169
174
183
98
82.7 51.8 173.9 173.8 158
142
101
17.1 18.08 18.42 17.2 17.2 16.7 16.9 17.1
177.4 187.9 195.4 165.1 165.2 165.4 167.8 179.2
95.04 79.4 48.7 165.1 165.2 155.2 133.2 105.3
19.18 19.68 20.06 18.72 18.75 18.78 18.91 19.33

LEGEND
Bypass Factor
Entering Dry-Bulb
Entering Wet-Bulb
Compressor Motor Power Input
Leaving Dry-Bulb
Leaving Wet-Bulb
Sensible Heat Capacity (1000 Btuh) Gross
Total Capacity (1000 Btuh) Gross

NOTES:
1. Direct interpolation is permissible. Do not extrapolate.
2. The following formulas may be used:
sensible capacity (Btuh)
tldb = tedb
1.10 x cfm
tlwb = Wet-bulb temperature corresponding to enthalpy of air leaving evaporator coil (hlwb)
total capacity (Btuh)
hlwb = hewb
4.5 x cfm
Where: hewb = Enthalpy of air entering evaporator coil
3. The SHC is based on 80 F edb temperature of air entering evaporator coil.
Below 80 F edb, subtract (corr factor x cfm) from SHC.
Above 80 F edb, add (corr factor x cfm) to SHC.

160

76
248
100
10.78
241
98.2
11.94
237
97.1
12.56
229.8
94.6
13.84
221.1
91.9
15.2
211.1
88.9
16.64
200
85.6
18.15
188.6
82.3
19.71

80
259
65.2
11.05
252
63.5
12.22
249
62.5
12.84
241
60.2
14.13
230.5
57.6
15.51
220.1
54.7
16.94
208.6
51.7
18.45
196
48.6
20.09

BYPASS
FACTOR
(BF)

79
81

.05
.10
.20
.30

1.04
.98
.87
.76

ENTERING AIR DRY-BULB TEMP (F)


78
77
76
75
under 75
82
83
84
85
over 85
Correction Factor
2.07 3.11 4.14 5.18
1.96 2.94 3.92 4.90
Use formula
1.74 2.62 3.49 4.36
shown below.
1.53 2.29 3.05 3.82

Interpolation is permissible.
Correction Factor = 1.10 x (1 BF) x (edb 80).
4. Use chart below for bypass factor.

CFM

54

58

4500
5250
6000
6750
7500

0.396
0.455
0.504
0.544
0.578

0.193
0.272
0.337
0.390
0.436

ENTERING WET-BULB (F)


62
67
72
Bypass Factor
0.054
0.053
0.067
0.077
0.065
0.077
0.121
0.077
0.088
0.193
0.094
0.100
0.244
0.108
0.114

76

80

0.000
0.000
0.000
0.000
0.000

0.000
0.000
0.000
0.000
0.000

COOLING CAPACITIES STANDARD UNITS (cont)


50HJ020 (18 Tons)
Temp (F)
Air Ent
Condenser
(Edb)
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW

60
70
75
85
95
105
115
125

5400/0.05
54
202
202
10.2
197
197
11.4
195
195
12.1
190
190
13.5
184
184
15
178
178
16.6
171
171
18.4
164
164
20.2

58
206
193
10.3
202
189
11.5
199
187
12.2
193
183
13.5
187
179
15
180
173
16.7
172
168
18.4
165
162
20.3

62
211
184
10.4
206
181
11.5
203
180
12.2
196
177
13.6
190
173
15.1
182
169
16.7
174
165
18.4
165
160
20.3

67
229
155
10.6
223
152
11.8
219
150
12.5
213
148
13.8
205
144
15.4
197
141
17
188
137
18.8
178
134
20.6

72
248
124
10.8
242
122
12
238
120
12.7
231
118
14.1
222
114
15.7
213
111
17.3
203
107
19.1
192
104
21

76
263
99.3
11
256
97
12.2
253
95.8
13
246
93.4
14.4
236
90.2
15.9
228
87.3
17.7
217
83.6
19.4
205
79.8
21.3

80
279
74.7
11.2
272
72.5
12.5
268
71.3
13.2
260
68.8
14.6
250
65.9
16.2
240
62.9
17.9
228
59.6
19.7
216
56.1
21.6

54
212
212
10.4
207
207
11.6
204
204
12.3
199
199
13.6
193
193
15.1
186
186
16.8
179
179
18.6
171
171
20.4

Air Entering Evaporator Cfm/BF


6300/0.06
Air Entering Evaporator Ewb (F)
58
62
67
72
76
215
218
235
254
269
205
199
166
131
103
10.4 10.4 10.7 10.9 11.1
209
212
228
247
262
202
196
163
129
101
11.6 11.6 11.9 12.1 12.3
206
209
225
244
258
199
195
162
127 99.3
12.3 12.3 12.6 12.8
13
201
202
218
236
251
195
191
159
125 96.9
13.7 13.7 13.9 14.2 14.5
194
195
210
227
241
190
187
156
121 93.7
15.2 15.2 15.5 15.8
16
187
188
201
217
232
184
183
152
118 90.8
16.8 16.8 17.1 17.4 17.8
179
179
192
207
221
178
178
149
114 87.1
18.6 18.6 18.9 19.2 19.5
171
171
182
196
208
171
171
145
110 83.2
20.4 20.4 20.8 21.1 21.4

7200/0.07
80
285
74.9
11.3
277
72.7
12.6
273
71.4
13.3
264
68.9
14.7
254
66.1
16.3
244
63.1
18
232
59.7
19.8
219
56.3
21.7

54
220
220
10.5
215
215
11.7
212
212
12.4
206
206
13.7
200
200
15.3
193
193
16.9
185
185
18.7
177
177
20.6

58
221
216
10.5
216
212
11.7
213
210
12.4
207
205
13.8
200
199
15.3
193
193
16.9
185
185
18.7
177
177
20.6

62
223
213
10.5
217
210
11.7
214
208
12.4
208
204
13.8
201
199
15.3
193
193
16.9
185
185
18.7
177
177
20.6

67
239
177
10.7
233
174
11.9
229
173
12.6
222
170
14
214
167
15.5
205
163
17.2
195
159
19
185
155
20.8

72
259
138
11
252
135
12.2
248
134
12.9
240
131
14.3
231
128
15.8
221
124
17.5
210
121
19.3
199
117
21.2

76
273
106
11.2
267
104
12.4
263
103
13.1
255
100
14.5
245
97.1
16.1
235
94.1
17.8
224
90.4
19.6
211
86.5
21.5

80
289
75
11.4
282
72.8
12.6
277
71.5
13.3
268
69
14.8
258
66.2
16.3
247
63.2
18
235
59.9
19.9
222
56.4
21.8

50HJ020 (18 Tons) (cont)


Temp (F)
Air Ent
Condenser
(Edb)
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW

60
70
75
85
95
105
115
125

54
227
227
10.5
222
222
11.8
219
219
12.5
213
213
13.8
206
206
15.4
199
199
17
191
191
18.8
182
182
20.7

58
227
226
10.6
222
221
11.8
219
218
12.5
213
213
13.8
206
206
15.4
199
199
17.1
191
191
18.8
182
182
20.7

62
228
224
10.6
222
221
11.8
219
218
12.5
213
213
13.8
206
206
15.4
199
199
17.1
191
191
18.8
182
182
20.7

67
243
187
10.7
236
185
12
232
183
12.7
225
180
14.1
217
177
15.6
208
173
17.3
198
169
19
188
165
20.9

9000/0.09
Air Entering Evaporator Ewb (F)
72
76
80
54
58
62
262
277
293
233
233
233
144
109 75.1 233
233
233
11 11.2 11.4 10.6 10.6 10.6
255
271
284
228
228
227
142
107 72.8 228
228
227
12.2 12.5 12.7 11.9 11.9 11.8
251
266
280
225
224
224
140
106 71.6 225
224
224
12.9 13.2 13.4 12.6 12.5 12.5
243
258
271
218
218
218
138
103 69.1 218
218
218
14.3 14.6 14.8 13.9 13.9 13.9
234
248
260
211
211
211
134
100 66.3 211
211
211
15.9 16.1 16.4 15.5 15.5 15.5
224
238
249
203
203
204
131 97.2 63.2 203
203
204
17.6 17.9 18.1 17.2 17.2 17.2
213
226
237
195
195
195
127 93.5
60
195
195
195
19.3 19.7 19.9 18.9 18.9 18.9
201
213
224
186
186
186
123 89.6 56.5 186
186
186
21.2 21.6 21.9 20.9 20.9 20.9

LEGEND
Bypass Factor
Entering Dry-Bulb
Entering Wet-Bulb
Compressor Motor Power Input
Leaving Dry-Bulb
Leaving Wet-Bulb
Sensible Heat Capacity (1000 Btuh) Gross
Total Capacity (1000 Btuh) Gross

NOTES:
1. Direct interpolation is permissible. Do not extrapolate.
2. The following formulas may be used:
sensible capacity (Btuh)
tldb = tedb
1.10 x cfm
tlwb = Wet-bulb temperature corresponding to enthalpy of air leaving evaporator coil (hlwb)
total capacity (Btuh)
hlwb = hewb
4.5 x cfm
Where: hewb = Enthalpy of air entering evaporator coil
3. The SHC is based on 80 F edb temperature of air entering evaporator coil.
Below 80 F edb, subtract (corr factor x cfm) from SHC.
Above 80 F edb, add (corr factor x cfm) to SHC.

67
246
198
10.8
239
195
12
235
193
12.7
228
190
14.1
220
187
15.6
210
183
17.3
201
179
19.1
190
174
21

72
265
151
11
258
148
12.3
254
147
13
245
144
14.4
236
141
15.9
226
137
17.6
215
133
19.4
203
129
21.3

76
280
113
11.3
272
110
12.5
268
109
13.2
260
107
14.6
250
103
16.2
240
100
17.9
228
96.6
19.7
215
92.6
21.6

80
295
75.1
11.5
287
72.9
12.7
282
71.7
13.4
273
69.2
14.8
262
66.4
16.4
251
63.4
18.1
238
60
19.9
225
56.6
21.9

BYPASS
FACTOR
(BF)

79
81

.05
.10
.20
.30

1.04
.98
.87
.76

ENTERING AIR DRY-BULB TEMP (F)


78
77
76
75
under 75
82
83
84
85
over 85
Correction Factor
2.07 3.11 4.14 5.18
1.96 2.94 3.92 4.90
Use formula
1.74 2.62 3.49 4.36
shown below.
1.53 2.29 3.05 3.82

Interpolation is permissible.
Correction Factor = 1.10 x (1 BF) x (edb 80).
4. Use chart below for bypass factor.

CFM

54

58

5400
6300
7200
8100
9000

0.424
0.478
0.525
0.562
0.594

0.238
0.304
0.364
0.414
0.456

ENTERING WET-BULB (F)


62
67
72
Bypass Factor
0.125
0.120
0.138
0.153
0.132
0.145
0.190
0.144
0.153
0.231
0.156
0.162
0.281
0.168
0.170

76

80

0.000
0.000
0.000
0.000
0.000

0.000
0.000
0.000
0.000
0.000

161

50HJ

BF
Edb
Ewb
kW
ldb
lwb
SHC
TC

Air Entering Evaporator Cfm/BF


8100/0.08

Performance data 50HJ (cont)


COOLING CAPACITIES STANDARD UNITS (cont)
50HJ024 (20 Tons)
Temp (F)
Air Ent
Condenser
(Edb)
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW

60
70
75
85
95
105
115
125

6,000/0.04
54
235
235
11.5
231
231
13.1
228
228
13.9
223
223
15.6
216
216
17.4
208
208
19.3
200
200
21.3
191
191
23.5

58
242
224
11.6
237
220
13.2
234
218
14
227
213
15.7
219
208
17.5
211
202
19.4
202
195
21.4
192
188
23.5

62
248
212
11.7
242
209
13.3
239
208
14.1
231
204
15.8
223
200
17.6
214
195
19.5
204
190
21.5
193
185
23.6

67
267
178
12
261
175
13.6
257
174
14.5
250
171
16.2
241
167
18.1
231
163
20
220
158
22
208
153
24.2

72
288
143
12.4
282
141
14
278
139
14.9
270
136
16.6
260
132
18.6
249
129
20.6
237
124
22.7
224
120
24.8

76
306
115
12.7
300
113
14.3
295
112
15.2
287
109
17.1
277
105
19
265
101
21
253
97.2
23.2
239
92.8
25.4

80
323
86.6
13
316
84.5
14.6
311
83.1
15.6
303
80.5
17.4
292
77.2
19.4
279
73.6
21.5
266
69.5
23.6
251
65.3
25.9

54
247
247
11.7
242
242
13.3
239
239
14.1
234
234
15.8
226
226
17.7
218
218
19.6
209
209
21.7
199
199
23.8

Air Entering Evaporator Cfm/BF


7,000/0.05
Air Entering Evaporator Ewb (F)
58
62
67
72
76
251
256
274
296
312
238
230
191
151
119
11.8 11.8 12.1 12.5 12.8
246
250
268
289
305
234
227
189
149
117
13.3 13.4 13.7 14.1 14.4
243
246
264
285
301
232
225
187
147
115
14.2 14.2 14.6
15 15.3
236
238
256
277
292
227
221
184
144
112
15.9 15.9 16.3 16.8 17.2
228
230
247
267
282
221
217
180
141
109
17.7 17.8 18.2 18.7 19.1
219
220
236
256
270
215
212
176
137
105
19.6 19.7 20.2 20.8 21.2
210
210
225
243
257
207
206
171
132
101
21.7 21.7 22.2 22.9 23.3
199
200
212
230
243
199
199
166
128 96.4
23.8 23.8 24.4
25 25.5

8,000/0.05
80
330
87
13.1
323
84.9
14.8
318
83.6
15.7
310
80.9
17.6
298
77.7
19.6
285
74
21.6
271
70
23.8
255
65.7
26

54
257
257
11.9
252
252
13.4
249
249
14.3
243
243
16
235
235
17.9
226
226
19.9
217
217
21.9
207
207
24.1

58
259
251
11.9
254
247
13.5
250
245
14.3
244
240
16.1
235
233
17.9
226
226
19.9
217
217
21.9
207
207
24.1

62
262
246
11.9
256
243
13.5
252
241
14.4
245
236
16.1
236
231
17.9
226
225
19.9
217
217
21.9
206
206
24.1

67
279
204
12.2
273
201
13.8
269
199
14.7
261
196
16.5
251
192
18.3
241
188
20.3
229
183
22.4
216
178
24.5

72
300
159
12.6
293
156
14.2
290
155
15.1
282
152
16.9
272
148
18.9
260
145
20.9
248
140
23
232
135
25.1

76
317
123
12.9
310
120
14.5
305
119
15.4
296
116
17.3
285
112
19.2
273
108
21.3
260
104
23.4
245
99.8
25.7

80
333
86.7
13.1
326
84.6
14.8
322
83.5
15.8
314
81.3
17.7
303
78
19.7
290
74.4
21.8
275
70.4
23.9
257
65.5
26.1

50HJ024 (20 Tons) (cont)


Temp (F)
Air Ent
Condenser
(Edb)
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW

60
70
75
85
95
105
115

50HJ

125

BF
Edb
Ewb
kW
ldb
lwb
SHC
TC

54
265
265
12
260
260
13.6
256
256
14.5
250
250
16.2
242
242
18.1
233
233
20.1
223
223
22.2
213
213
24.3

58
266
262
12
261
258
13.6
257
255
14.5
250
250
16.2
242
242
18.1
233
233
20.1
223
223
22.1
212
212
24.3

Air Entering Evaporator Cfm/BF


9,000/0.06
10,000/0.07
Air Entering Evaporator Ewb (F)
62
67
72
76
80
54
58
62
67
72
267
284
305
321
338
272
272
272
287
307
260
216
166
126
87
272
271
271
227
173
12 12.3 12.7 12.9 13.2 12.1 12.1 12.1 12.4 12.7
261
277
298
315
331
266
267
267
281
301
256
213
164
124
85
266
267
267
225
171
13.6 13.9 14.3 14.6 14.9 13.7 13.7 13.7
14 14.3
258
273
294
310
326
263
263
263
277
296
254
211
162
123 83.7 263
263
263
223
169
14.5 14.8 15.2 15.5 15.8 14.6 14.6 14.6 14.9 15.2
250
265
285
301
316
257
256
256
268
287
249
208
159
120
81
257
256
256
220
166
16.2 16.5
17 17.4 17.7 16.4 16.4 16.4 16.6
17
242
255
274
288
304
248
248
248
258
276
242
204
155
116 77.8 248
248
248
215
162
18.1 18.4 18.9 19.3 19.7 18.3 18.3 18.2 18.5
19
233
244
263
275
291
239
239
239
247
264
233
200
152
112 74.2 239
239
239
211
158
20.1 20.4
21 21.4 21.8 20.3 20.2 20.2 20.5
21
223
232
250
262
276
229
228
228
235
251
223
195
147
108 70.2 229
228
228
206
154
22.1 22.5 23.1 23.5
24
22.3 22.3 22.3 22.6 23.1
212
219
234
247
258
218
217
217
222
235
212
189
142
103 65.4 218
217
217
200
148
24.3 24.6 25.2 25.7 26.2 24.5 24.5 24.5 24.7 25.3

LEGEND
Bypass Factor
Entering Dry-Bulb
Entering Wet-Bulb
Compressor Motor Power Input
Leaving Dry-Bulb
Leaving Wet-Bulb
Sensible Heat Capacity (1000 Btuh) Gross
Total Capacity (1000 Btuh) Gross

NOTES:
1. Direct interpolation is permissible. Do not extrapolate.
2. The following formulas may be used:
sensible capacity (Btuh)
tldb = tedb
1.10 x cfm
tlwb = Wet-bulb temperature corresponding to enthalpy of air leaving evaporator coil (hlwb)
total capacity (Btuh)
hlwb = hewb
4.5 x cfm
Where: hewb = Enthalpy of air entering evaporator coil
3. The SHC is based on 80 F edb temperature of air entering evaporator coil.
Below 80 F edb, subtract (corr factor x cfm) from SHC.
Above 80 F edb, add (corr factor x cfm) to SHC.

162

76
325
130
13
317
127
14.6
312
126
15.6
303
123
17.4
292
120
19.4
279
116
21.5
263
111
23.6
248
106
25.8

80
340
86.7
13.3
333
84.7
15
327
83.4
15.9
317
80.7
17.7
306
77.6
19.7
291
73.9
21.8
276
69.9
24
259
65.2
26.2

BYPASS
FACTOR
(BF)

79
81

.05
.10
.20
.30

1.04
.98
.87
.76

ENTERING AIR DRY-BULB TEMP (F)


78
77
76
75
under 75
82
83
84
85
over 85
Correction Factor
2.07 3.11 4.14 5.18
1.96 2.94 3.92 4.90
Use formula
1.74 2.62 3.49 4.36
shown below.
1.53 2.29 3.05 3.82

Interpolation is permissible.
Correction Factor = 1.10 x (1 BF) x (edb 80).
4. Use chart below for bypass factor.

CFM

54

58

6,000
7,000
8,000
9,000
10,000

0.386
0.444
0.492
0.532
0.566

0.197
0.260
0.321
0.375
0.420

ENTERING WET-BULB (F)


62
67
72
Bypass Factor
0.108
0.109
0.134
0.131
0.121
0.138
0.163
0.133
0.145
0.205
0.146
0.154
0.245
0.158
0.164

76

80

0.000
0.000
0.000
0.000
0.000

0.000
0.000
0.000
0.000
0.000

COOLING CAPACITIES STANDARD UNITS (cont)


50HJ028 (25 Tons)
Temp (F)
Air Ent
Condenser
(Edb)
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW

60
70
75
85
95
105
115
125

7,500/0.05
54
287
287
15.5
279
279
17
275
275
17.9
267
267
19.8
259
259
22.1
253
253
24.9
246
246
28.1
238
238
31.6

58
296
274
15.7
286
267
17.2
281
264
18.1
272
257
19.9
263
251
22.2
256
246
25
249
240
28.2
240
234
31.7

62
304
261
15.9
293
255
17.3
287
252
18.2
277
247
20
267
242
22.3
260
239
25.1
252
235
28.3
242
230
31.7

67
331
220
16.5
318
214
18
311
212
18.8
299
207
20.6
288
202
22.8
279
198
25.4
270
195
28.6
259
190
32

72
359
178
17.3
345
173
18.7
338
170
19.5
324
165
21.2
311
160
23.4
301
156
25.9
291
152
29
279
148
32.4

76
385
145
17.9
367
139
19.3
360
136
20.1
345
131
21.8
331
126
23.9
318
122
26.4
305
118
29.3
293
114
32.6

80
408
110
18.6
392
105
20
383
102
20.8
366
97.3
22.4
350
92.5
24.5
335
87.9
26.9
320
83.5
29.6
305
79.2
32.9

54
297
297
15.7
288
288
17.2
283
283
18.1
274
274
20
267
267
22.3
260
260
25.1
253
253
28.3
245
245
31.8

Air Entering Evaporator Cfm/BF


8,250/0.06
Air Entering Evaporator Ewb (F)
58
62
67
72
76
304
310
336
367
390
285
273
229
185
148
15.9
16 16.7 17.4 18.1
293
298
323
350
372
278
268
224
178
142
17.3 17.5 18.1 18.8 19.4
288
293
316
343
365
274
265
221
176
139
18.2 18.4 18.9 19.7 20.3
278
282
304
329
350
267
259
216
171
134
20.1 20.1 20.7 21.4
22
270
273
293
315
335
261
255
212
166
129
22.4 22.5 22.9 23.5
24
262
264
282
304
322
255
250
207
162
125
25.1 25.1 25.5
26 26.5
255
256
274
294
309
250
246
204
158
121
28.3 28.3 28.6
29 29.4
246
246
262
281
295
243
240
199
153
116
31.8 31.8 32.1 32.4 32.7

9,500/0.07
80
414
110
18.7
397
105
20.1
388
103
20.9
370
97.3
22.6
354
92.5
24.6
338
87.8
26.9
323
83.4
29.7
310
79.7
33

54
311
311
16
301
301
17.5
296
296
18.4
286
286
20.2
278
278
22.6
269
269
25.2
262
262
28.4
253
253
31.9

58
315
303
16.1
303
294
17.6
298
290
18.5
287
282
20.3
279
276
22.6
270
268
25.2
262
261
28.4
253
253
31.9

62
319
294
16.2
306
287
17.7
300
284
18.5
289
278
20.3
281
273
22.6
270
267
25.2
262
261
28.4
253
253
31.9

67
345
246
16.9
329
239
18.3
323
237
19.1
311
232
20.9
299
227
23.1
287
222
25.6
277
218
28.7
266
214
32.1

72
375
194
17.6
357
188
19
349
185
19.8
334
180
21.5
322
175
23.6
308
171
26.1
298
167
29.1
284
162
32.5

76
398
152
18.3
381
147
19.7
372
144
20.5
355
139
22.1
340
134
24.2
326
129
26.6
312
125
29.4
298
120
32.7

80
421
111
19
403
105
20.3
394
103
21.1
375
97.3
22.7
358
92.4
24.7
342
87.7
27.1
328
83.9
29.9
313
79.9
33.1

50HJ028 (25 Tons) (cont)


Temp (F)
Air Ent
Condenser
(Edb)
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW

60
70
75
85
95
105
115
125

54
322
322
16.3
311
311
17.8
306
306
18.7
295
295
20.5
286
286
22.7
277
277
25.4
268
268
28.5
260
260
32

58
324
317
16.4
312
308
17.8
307
304
18.7
296
295
20.5
286
286
22.7
277
277
25.4
269
269
28.5
259
259
32

62
327
313
16.4
314
305
17.9
308
302
18.7
297
294
20.5
286
286
22.7
277
277
25.4
269
269
28.5
259
259
32

67
351
260
17
336
255
18.4
329
252
19.3
315
246
21
303
241
23.1
290
236
25.7
281
232
28.7
269
227
32.1

12,000/0.09
Air Entering Evaporator Ewb (F)
72
76
80
54
58
62
67
72
380
404
429
332
333
334
357
386
203
157
111
332
330
329
276
212
17.8 18.5 19.2 16.6 16.6 16.6 17.2
18
364
386
408
320
320
321
341
368
198
151
105
320
320
319
269
206
19.2 19.8 20.5
18
18
18 18.5 19.3
356
378
398
315
315
315
333
360
195
149
103
315
314
314
266
203
20 20.6 21.3 18.9 18.9 18.9 19.4 20.1
340
362
379
303
303
303
319
344
189
144 97.3 303
303
303
260
198
21.7 22.3 22.8 20.7 20.7 20.7 21.1 21.8
327
344
364
293
293
294
307
330
185
138
93
293
293
294
255
193
23.8 24.3 24.9 22.9 22.9 22.9 23.2 23.9
312
329
347
284
284
285
295
314
179
133 88.3 284
284
285
250
188
26.2 26.7 27.2 25.5 25.6 25.6 25.8 26.3
300
315
332
274
274
275
283
303
176
129 84.4 274
274
275
245
184
29.2 29.5
30
28.6 28.6 28.6 28.8 29.2
287
300
316
265
265
264
271
289
171
125
80
265
265
264
240
179
32.5 32.8 33.2 32.1 32.1 32.1 32.2 32.5

LEGEND
Bypass Factor
Entering Dry-Bulb
Entering Wet-Bulb
Compressor Motor Power Input
Leaving Dry-Bulb
Leaving Wet-Bulb
Sensible Heat Capacity (1000 Btuh) Gross
Total Capacity (1000 Btuh) Gross

NOTES:
1. Direct interpolation is permissible. Do not extrapolate.
2. The following formulas may be used:
sensible capacity (Btuh)
tldb = tedb
1.10 x cfm
tlwb = Wet-bulb temperature corresponding to enthalpy of air leaving evaporator coil (hlwb)
total capacity (Btuh)
hlwb = hewb
4.5 x cfm
Where: hewb = Enthalpy of air entering evaporator coil
3. The SHC is based on 80 F edb temperature of air entering evaporator coil.
Below 80 F edb, subtract (corr factor x cfm) from SHC.
Above 80 F edb, add (corr factor x cfm) to SHC.

76
410
162
18.6
392
156
20
383
153
20.8
365
148
22.4
347
142
24.4
331
137
26.7
317
133
29.5
302
129
32.8

80
432
111
19.2
414
106
20.6
404
103
21.4
385
97.9
23
366
92.8
24.9
352
88.7
27.3
333
84
30
318
80.1
33.3

BYPASS
FACTOR
(BF)

79
81

.05
.10
.20
.30

1.04
.98
.87
.76

ENTERING AIR DRY-BULB TEMP (F)


78
77
76
75
under 75
82
83
84
85
over 85
Correction Factor
2.07 3.11 4.14 5.18
1.96 2.94 3.92 4.90
Use formula
1.74 2.62 3.49 4.36
shown below.
1.53 2.29 3.05 3.82

Interpolation is permissible.
Correction Factor = 1.10 x (1 BF) x (edb 80).
4. Use chart below for bypass factor.

CFM

54

58

7,500
8,250
9,500
10,750
12,000

0.407
0.443
0.494
0.536
0.571

0.208
0.256
0.324
0.380
0.427

ENTERING WET-BULB (F)


62
67
72
Bypass Factor
0.097
0.104
0.123
0.110
0.112
0.128
0.138
0.123
0.136
0.181
0.134
0.145
0.232
0.145
0.154

76

80

0.000
0.000
0.000
0.000
0.000

0.000
0.000
0.000
0.000
0.000

163

50HJ

BF
Edb
Ewb
kW
ldb
lwb
SHC
TC

Air Entering Evaporator Cfm/BF


10,750/0.08

Performance data 50HJ (cont)


COOLING CAPACITIES UNITS WITH HUMIDI-MIZER ADAPTIVE DEHUMIDIFICATION SYSTEM OPTION
50HJ004 (3 TONS) SUBCOOLING MODE
Temp (F)
Air Ent
Condenser
(Edb)
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW

75
85
95
105
115
125

900/0.14
72
41.3
17.5
2.19
38.6
15.2
2.46
35.9
13.0
2.74
33.8
10.9
3.05
31.8
9.0
3.40
28.7
6.9
3.78

67
37.3
22.4
2.14
34.4
20.1
2.40
31.4
17.9
2.68
29.7
15.8
3.00
28.0
13.7
3.36
26.3
12.2
3.73

62
34.3
26.7
2.10
31.6
25.1
2.37
28.8
23.3
2.63
27.4
21.0
2.97
25.5
18.4
3.31
23.4
17.3
3.66

Air Entering Evaporator Cfm/BF


1200/0.17
Air Entering Evaporator Ewb (F)
72
67
62
43.5
39.2
35.9
19.6
25.5
31.2
2.21
2.16
2.14
41.3
37.5
33.3
17.1
23.2
29.0
2.47
2.43
2.40
39.2
35.9
30.6
14.5
21.1
26.9
2.76
2.74
2.67
36.3
32.2
28.7
12.5
18.9
24.6
3.09
3.04
2.99
33.2
28.7
26.5
10.3
16.8
22.3
3.45
3.38
3.32
29.7
25.5
22.9
7.9
14.5
20.6
3.84
3.77
3.71

1500/0.20
72
45.5
21.5
2.24
43.5
18.9
2.51
41.3
16.1
2.80
38.1
14.0
3.12
34.9
11.9
3.48
31.3
9.2
3.87

67
41.6
28.5
2.19
38.6
26.3
2.45
35.7
24.2
2.75
32.8
21.7
3.07
30.0
19.3
3.41
27.1
17.3
3.79

62
38.2
35.2
2.16
35.5
32.9
2.42
32.9
30.6
2.71
30.4
28.1
3.03
27.9
25.2
3.37
25.5
22.3
3.75

50HJ004 (3 TONS) HOT GAS REHEAT MODE


75 Dry Bulb
62.5 Wet Bulb
(50% Relative)

Temp (F)
Air Ent
Condenser
(Edb)

80
75
70
60
50

50HJ

40

BF
Edb
Ewb
kW
SHC
TC

TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW

900
12.83
4.06
2.12
13.61
4.62
2.11
14.39
5.17
2.10
15.95
6.27
2.09
17.50
7.37
2.07
19.06
8.47
2.06

1200
15.84
5.69
2.12
16.44
6.16
2.11
17.05
6.62
2.10
18.26
7.55
2.09
19.48
8.47
2.07
20.69
9.40
2.06

LEGEND
Bypass Factor
Entering Dry Bulb
Entering Wet Bulb
Compressor Motor Power Input
Sensible Heat Capacity (1000 Btuh) Gross
Total Capacity (1000 Btuh) Gross

NOTES:
1. Direct interpolation is permissible. Do not extrapolate.

164

1500
18.20
6.98
2.12
18.67
7.37
2.11
19.14
7.77
2.10
20.08
8.56
2.09
21.02
9.35
2.07
21.07
10.13
2.06

Air Entering Evaporator Ewb (F)


75 Dry Bulb
64 Wet Bulb
(55% Relative)
Air Entering Evaporator Cfm
900
1200
1500
13.24
16.31
18.73
2.21
3.83
5.12
2.13
2.13
2.13
14.03
16.93
19.20
2.89
4.43
5.65
2.12
2.12
2.12
14.82
17.54
19.68
3.58
5.03
6.18
2.12
2.12
2.12
16.40
18.77
20.63
4.95
6.23
7.24
2.11
2.11
2.11
17.98
20.00
21.58
6.32
7.43
8.30
2.10
2.10
2.10
19.56
21.23
22.54
7.71
8.63
9.36
2.08
2.08
2.08

75 Dry Bulb
65.3 Wet Bulb
(60% Relative)
900
13.58
.59
2.14
14.39
1.40
2.14
15.19
2.20
2.13
16.79
3.81
2.12
18.40
5.42
2.12
20.00
7.02
2.11

1200
16.72
2.20
2.14
17.34
2.93
2.14
17.96
3.65
2.13
19.21
5.09
2.12
20.45
6.52
2.12
21.70
7.95
2.11

1500
19.18
3.50
2.14
19.67
4.15
2.14
20.15
4.80
2.13
21.11
6.10
2.12
22.07
7.39
2.12
23.03
8.69
2.11

2. The following formulas may be used:


sensible capacity (Btuh)
tldb = tedb
1.10 x cfm
tlwb = Wet-bulb temperature corresponding to enthalpy of air
leaving evaporator coil (hlwb)
hlwb = hewb

total capacity (Btuh)


4.5 x cfm

Where: hewb = Enthalpy of air entering evaporator coil.


3. The SHC is based on 80 F edb temperature of air entering evaporator coil.
Below 80 F edb, subtract (corr factor x cfm) from SHC.
Above 80 F edb, add (corr factor x cfm) to SHC.
Correction Factor = 1.10 x (1 BF) x (edb 80).

COOLING CAPACITIES UNITS WITH HUMIDI-MIZER ADAPTIVE DEHUMIDIFICATION SYSTEM OPTION (cont)
50HJ005 (4 TONS) SUBCOOLING MODE
Temp (F)
Air Ent
Condenser
(Edb)
75
85
95
105
115
125

TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW

1200/0.17
72
52.9
22.7
2.87
49.2
19.8
3.26
45.8
17.2
3.71
41.6
13.5
4.20
37.2
9.9
4.73
32.4
7.2
5.29

67
47.5
28.4
2.86
43.8
25.5
3.25
40.1
22.5
3.68
37.0
19.5
4.17
33.2
16.4
4.68
28.1
12.9
5.23

62
41.5
33.4
2.82
37.1
30.4
3.21
32.8
27.3
3.64
29.7
23.9
4.11
27.1
20.7
4.62
24.9
18.3
5.15

72
55.7
26.1
2.89
52.1
22.2
3.28
48.2
18.4
3.72
43.2
14.7
4.20
38.4
11.3
4.74
33.8
8.4
5.30

Air Entering Evaporator Cfm/BF


1450/0.19
1600/0.21
Air Entering Evaporator Ewb (F)
67
62
72
67
50.9
47.5
57.0
51.7
34.1
38.9
25.9
33.7
2.87
2.84
2.89
2.86
47.2
43.6
52.9
47.9
29.5
35.8
22.4
31.1
3.26
3.23
3.28
3.26
43.6
39.4
48.8
44.0
24.8
32.6
19.0
28.1
3.69
3.67
3.72
3.69
38.9
35.4
43.9
39.7
21.7
29.2
15.0
23.7
4.17
4.14
4.20
4.17
34.0
30.8
39.4
35.5
18.5
25.6
11.2
19.7
4.71
4.64
4.73
4.72
28.1
27.4
35.3
30.5
14.5
21.9
16.8
21.1
5.25
5.19
5.29
5.27

2000/0.24
62
48.1
41.6
2.85
43.7
38.7
3.24
39.3
35.9
3.67
34.7
30.6
4.15
30.0
25.4
4.65
26.6
21.2
5.21

72
60.5
29.4
2.90
55.4
24.2
3.28
51.7
20.7
3.74
46.5
16.4
4.22
41.3
12.4
4.74
36.1
9.5
5.30

67
55.6
39.1
2.88
51.4
36.0
3.26
47.4
33.0
3.70
41.4
27.8
4.19
35.2
22.4
4.72
32.0
18.3
5.29

62
52.1
47.5
2.85
47.0
44.3
3.24
43.0
41.0
3.68
37.5
35.1
4.16
31.9
28.6
4.69
28.7
24.1
5.25

50HJ005 (4 TONS) HOT GAS REHEAT MODE*


75 Dry Bulb
62.5 Wet Bulb
(50% Relative)

Temp (F)
Air Ent
Condenser
(Edb)

80
75
70
60
50
40

TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW

1200
12.13
1.01
2.76
13.25
1.60
7.54
14.37
2.18
2.70
16.60
3.35
2.64
18.83
4.51
2.59
21.06
5.68
2.53

1450
14.30
1.60
2.76
15.28
2.14
7.54
16.27
2.69
2.70
18.24
3.79
2.64
20.22
4.89
2.59
22.19
5.99
2.53

1600
15.43
1.90
2.76
16.34
2.43
7.57
17.26
2.96
2.70
19.10
4.03
2.64
20.94
5.09
2.59
22.78
6.16
2.53

Air Entering Evaporator Ewb (F)


75 Dry Bulb
64 Wet Bulb
(55% Relative)
Air Entering Evaporator Cfm
1200
1450
1600
14.98
17.20
18.36
-0.18
0.41
0.72
2.75
2.75
2.75
15.96
18.05
19.14
0.50
1.05
1.34
7.61
7.64
7.66
16.94
18.90
19.92
1.17
1.69
1.96
2.70
2.70
2.70
18.91
20.60
21.48
2.52
2.97
3.21
2.65
2.65
2.65
20.87
22.30
23.04
3.86
4.25
4.45
2.60
2.60
2.60
22.84
24.00
24.61
5.21
5.53
5.69
2.55
2.55
2.55

1200
17.44
-1.20
2.74
18.31
-0.45
7.66
19.17
0.30
2.70
20.91
1.80
2.65
22.65
3.30
2.61
24.38
4.80
2.57

1450
19.71
-0.61
2.74
20.44
0.11
7.70
21.17
0.82
2.70
22.64
2.25
2.65
24.10
3.69
2.61
25.57
5.12
2.57

1600
20.90
-0.30
2.74
21.56
0.40
7.71
22.22
1.10
2.70
23.54
2.50
2.65
24.86
3.89
2.61
26.19
5.29
2.57

2. The following formulas may be used:


sensible capacity (Btuh)
tldb = tedb
1.10 x cfm
tlwb = Wet-bulb temperature corresponding to enthalpy of air
leaving evaporator coil (hlwb)
hlwb = hewb

total capacity (Btuh)


4.5 x cfm

Where: hewb = Enthalpy of air entering evaporator coil.


3. The SHC is based on 80 F edb temperature of air entering evaporator coil.
Below 80 F edb, subtract (corr factor x cfm) from SHC.
Above 80 F edb, add (corr factor x cfm) to SHC.
Correction Factor = 1.10 x (1 BF) x (edb 80).

165

50HJ

LEGEND
BF
Bypass Factor
Edb Entering Dry Bulb
Ewb Entering Wet Bulb
kW Compressor Motor Power Input
SHC Sensible Heat Capacity (1000 Btuh) Gross
TC
Total Capacity (1000 Btuh) Gross
*Negative SHC value indicates that the air entering the coil is being
heated.
NOTES:
1. Direct interpolation is permissible. Do not extrapolate.

75 Dry Bulb
65.3 Wet Bulb
(60% Relative)

Performance data 50HJ (cont)


COOLING CAPACITIES UNITS WITH HUMIDI-MIZER ADAPTIVE DEHUMIDIFICATION SYSTEM OPTION (cont)
50HJ006 (5 TONS) SUBCOOLING MODE
Temp (F)
Air Ent
Condenser
(Edb)
75
85
95
105
115
125

TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW

1500/0.08
72
69.9
29.0
3.61
65.9
25.3
4.05
61.9
21.6
4.53
57.7
18.1
5.05
53.4
14.7
5.60
48.7
10.9
6.26

67
62.7
36.9
3.55
59.1
34.0
3.97
55.2
31.1
4.43
51.1
27.8
4.93
47.2
24.6
5.49
42.0
19.6
6.12

62
56.2
43.9
3.51
51.7
41.9
3.91
47.7
40.0
4.35
44.9
35.7
4.84
42.0
31.5
5.40
36.9
28.0
6.02

72
74.7
31.7
3.64
70.6
27.5
4.07
66.5
23.5
4.55
61.8
20.0
5.09
56.6
16.5
5.64
51.3
12.5
6.28

Air Entering Evaporator Cfm/BF


1750/0.09
2000/0.11
Air Entering Evaporator Ewb (F)
67
62
72
67
67.3
61.0
78.5
71.2
40.5
51.2
34.5
44.2
3.58
3.49
3.65
3.60
63.2
56.3
75.5
66.8
37.6
48.0
30.7
41.6
4.01
3.92
4.11
4.00
58.8
51.3
70.4
61.9
34.5
44.6
26.0
38.6
4.47
4.37
4.56
4.42
54.5
47.7
65.1
57.2
31.2
40.1
22.1
34.3
4.97
4.88
5.11
4.96
50.0
44.2
59.6
52.5
27.8
35.7
18.2
30.0
5.52
5.45
5.69
5.55
45.0
39.0
54.1
46.8
22.2
31.5
13.5
24.0
6.18
6.09
6.33
6.18

2500/0.13
62
64.8
55.4
3.51
60.7
52.0
3.95
55.7
47.9
4.41
50.8
43.5
4.92
46.2
39.0
5.48
40.9
34.0
6.13

72
81.7
37.8
3.62
78.1
33.8
4.08
74.2
30.0
4.58
68.4
26.1
5.11
62.6
22.1
5.69
56.9
16.5
6.33

67
75.5
52.0
3.58
70.8
47.4
4.02
65.9
42.8
4.49
60.3
38.9
5.03
54.9
34.9
5.61
49.2
28.0
6.27

62
69.3
62.8
3.51
65.1
58.0
3.96
60.6
52.6
4.44
56.1
48.5
4.98
51.6
44.3
5.57
45.9
38.8
6.22

50HJ006 (5 TONS) HOT GAS REHEAT MODE*


75 Dry Bulb
62.5 Wet Bulb
(50% Relative)

Temp (F)
Air Ent
Condenser
(Edb)

80
75
70
60
50

50HJ

40

TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW

1500
17.67
-0.39
3.45
18.55
0.28
3.43
19.44
0.95
3.42
21.20
2.30
3.38
22.96
3.64
3.35
24.73
4.99
3.32

1750
19.23
0.07
3.45
20.03
0.71
3.43
20.83
1.36
3.42
22.44
2.65
3.38
24.05
3.94
3.35
25.66
5.23
3.32

2000
20.59
0.46
3.45
21.32
1.09
3.43
22.06
1.71
3.42
23.53
2.95
3.38
25.00
4.20
3.35
26.48
5.45
3.32

Air Entering Evaporator Ewb (F)


75 Dry Bulb
64 Wet Bulb
(55% Relative)
Air Entering Evaporator Cfm
1500
1750
2000
17.51
19.09
20.48
-1.61
-1.15
-0.75
3.48
3.48
3.48
18.45
19.95
21.27
-0.85
-0.42
-0.04
3.46
3.46
3.46
19.39
20.81
22.06
-0.09
0.32
0.68
3.45
3.45
3.45
21.27
22.54
23.65
1.44
1.80
2.11
3.42
3.42
3.42
23.15
24.26
25.23
2.97
3.27
3.53
3.40
3.40
3.40
25.03
25.98
26.81
4.50
4.75
4.96
3.37
3.37
3.37

LEGEND
BF
Bypass Factor
Edb Entering Dry Bulb
Ewb Entering Wet Bulb
kW Compressor Motor Power Input
SHC Sensible Heat Capacity (1000 Btuh) Gross
TC
Total Capacity (1000 Btuh) Gross
*Negative SHC value indicates that the air entering the coil is being
heated.
NOTES:
1. Direct interpolation is permissible. Do not extrapolate.

166

75 Dry Bulb
65.3 Wet Bulb
(60% Relative)
1500
17.37
-2.67
3.50
18.36
-1.83
3.49
19.35
-0.99
3.48
21.33
0.70
3.46
23.31
2.39
3.43
25.28
4.07
3.41

1750
18.98
-2.21
3.50
19.89
-1.39
3.49
20.80
-0.58
3.48
22.62
1.06
3.46
24.43
2.69
3.43
26.25
4.32
3.41

2000
20.39
-1.80
3.50
21.23
-1.01
3.49
22.07
-0.22
3.48
23.75
1.37
3.46
25.42
2.96
3.43
27.10
4.54
3.41

2. The following formulas may be used:


sensible capacity (Btuh)
tldb = tedb
1.10 x cfm
tlwb = Wet-bulb temperature corresponding to enthalpy of air
leaving evaporator coil (hlwb)
hlwb = hewb

total capacity (Btuh)


4.5 x cfm

Where: hewb = Enthalpy of air entering evaporator coil.


3. The SHC is based on 80 F edb temperature of air entering evaporator coil.
Below 80 F edb, subtract (corr factor x cfm) from SHC.
Above 80 F edb, add (corr factor x cfm) to SHC.
Correction Factor = 1.10 x (1 BF) x (edb 80).

COOLING CAPACITIES UNITS WITH HUMIDI-MIZER ADAPTIVE DEHUMIDIFICATION SYSTEM OPTION (cont)
50HJ007 (6 TONS) SUBCOOLING MODE
Temp (F)
Air Ent
Condenser
(Edb)
75
85
95
105
115
125

TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW

1800/0.05
72
82.6
36.0
4.60
78.2
31.4
5.16
73.8
27.0
5.75
68.4
22.3
6.37
63.4
18.1
7.04
55.5
15.3
7.80

67
75.6
44.8
4.52
71.6
41.2
5.03
67.4
37.6
5.60
62.6
33.5
6.22
57.8
29.5
6.89
49.6
24.0
7.61

62
68.5
55.4
4.36
64.5
51.7
4.89
60.2
47.9
5.44
55.9
43.5
6.06
50.7
38.9
6.68
45.8
35.2
7.38

72
84.9
37.5
4.67
80.9
33.0
5.22
76.3
28.2
5.80
71.4
23.4
6.45
66.0
18.8
7.10
58.4
15.7
7.83

Air Entering Evaporator Cfm/BF


2100/0.06
2400/0.06
Air Entering Evaporator Ewb (F)
67
62
72
67
78.0
70.9
85.9
79.5
49.1
59.7
38.8
51.1
4.57
4.46
4.70
4.57
73.4
65.8
82.0
74.4
44.7
55.8
34.7
47.4
5.11
4.96
5.26
5.09
68.3
60.5
77.5
69.3
40.0
51.6
30.2
43.7
5.66
5.48
5.84
5.68
64.3
56.2
72.1
64.6
36.5
48.0
25.4
38.4
6.27
6.10
6.46
6.29
60.1
51.5
66.4
59.6
32.9
44.1
20.7
33.3
6.91
6.74
7.12
6.95
52.4
46.1
57.6
52.1
27.5
39.0
17.5
27.5
7.67
7.49
7.89
7.72

3000/0.08
62
73.5
64.0
4.45
67.9
60.1
4.97
62.3
56.2
5.53
58.3
50.2
6.16
54.5
43.8
6.83
49.5
38.4
7.58

72
89.1
41.8
4.77
85.8
37.6
5.32
82.0
33.6
5.90
75.7
29.1
6.53
68.8
24.3
7.16
59.2
20.9
7.92

67
82.7
58.1
4.61
78.2
54.3
5.17
72.8
49.2
5.73
67.0
45.2
6.36
60.8
41.4
7.01
52.8
34.6
7.78

62
77.0
70.2
4.51
72.3
66.7
5.04
67.5
62.9
5.60
62.4
56.2
6.24
57.5
49.7
6.92
53.1
44.4
7.70

50HJ007 (6 TONS) HOT GAS REHEAT MODE*


75 Dry Bulb
62.5 Wet Bulb
(50% Relative)

Temp (F)
Air Ent
Condenser
(Edb)

80
75
70
60
50
40

TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW

1800
27.41
5.74
4.40
27.98
5.73
4.45
28.55
5.71
4.51
29.70
5.67
4.62
30.84
5.63
4.74
31.99
5.60
4.86

2100
28.12
7.61
4.39
28.66
7.48
4.45
29.19
7.35
4.51
30.25
7.09
4.62
31.32
6.83
4.74
32.38
6.57
4.86

2400
28.75
9.25
4.39
29.24
9.02
4.45
29.74
8.79
4.51
30.74
8.34
4.62
31.73
7.89
4.74
32.73
7.43
4.86

Air Entering Evaporator Ewb (F)


75 Dry Bulb
64 Wet Bulb
(55% Relative)
Air Entering Evaporator Cfm
1800
2100
2400
27.25
27.98
28.62
1.68
3.52
5.14
4.44
4.44
4.44
27.89
28.58
29.18
1.92
3.65
5.18
4.50
4.50
4.50
28.53
29.18
29.74
2.17
3.79
5.22
4.57
4.57
4.57
29.80
30.37
30.86
2.65
4.06
5.29
4.69
4.69
4.69
31.07
31.56
31.98
3.14
4.33
5.37
4.82
4.82
4.82
32.35
32.75
33.12
3.63
4.59
5.44
4.95
4.95
4.95

1800
27.12
-1.85
4.49
27.81
-1.38
4.55
28.51
-0.91
4.62
29.89
0.04
4.75
31.27
0.98
4.89
32.66
1.92
5.02

2100
27.86
-0.03
4.49
28.52
0.34
4.55
29.17
0.70
4.62
30.47
1.43
4.75
31.77
2.15
4.89
33.07
2.88
5.02

2400
28.51
1.58
4.49
29.13
1.85
4.55
29.74
2.12
4.62
30.97
2.65
4.75
32.20
3.19
4.89
33.43
3.72
5.02

2. The following formulas may be used:


sensible capacity (Btuh)
tldb = tedb
1.10 x cfm
tlwb = Wet-bulb temperature corresponding to enthalpy of air
leaving evaporator coil (hlwb)
hlwb = hewb

total capacity (Btuh)


4.5 x cfm

Where: hewb = Enthalpy of air entering evaporator coil.


3. The SHC is based on 80 F edb temperature of air entering evaporator coil.
Below 80 F edb, subtract (corr factor x cfm) from SHC.
Above 80 F edb, add (corr factor x cfm) to SHC.
Correction Factor = 1.10 x (1 BF) x (edb 80).

167

50HJ

LEGEND
BF
Bypass Factor
Edb Entering Dry Bulb
Ewb Entering Wet Bulb
kW Compressor Motor Power Input
SHC Sensible Heat Capacity (1000 Btuh) Gross
TC
Total Capacity (1000 Btuh) Gross
*Negative SHC value indicates that the air entering the coil is being
heated.
NOTES:
1. Direct interpolation is permissible. Do not extrapolate.

75 Dry Bulb
65.3 Wet Bulb
(60% Relative)

Performance data 50HJ (cont)


COOLING CAPACITIES UNITS WITH HUMIDI-MIZER ADAPTIVE DEHUMIDIFICATION SYSTEM OPTION (cont)
50HJ008 (71/2 TONS) SUBCOOLING MODE
Temp (F)
Air Ent
Condenser
(Edb)
75
85
95
105
115
125

TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW

Air Entering Evaporator Cfm/BF


3000/0.11
Air Entering Evaporator Ewb (F)
72
67
62
107.3
99.6
90.7
53.3
69.2
83.7
5.16
5.11
5.06
105.1
96.5
87.5
52.8
68.4
82.2
5.89
5.82
5.77
101.6
92.9
83.5
51.9
67.2
80.2
6.69
6.61
6.53
97.6
88.8
79.6
50.7
65.9
78.0
7.55
7.48
7.36
93.2
84.5
75.4
49.3
64.2
75.3
8.46
8.37
8.27
88.3
80.0
71.9
47.5
62.6
71.8
9.43
9.34
9.24

2250/0.10
72
105.5
50.6
5.15
102.5
49.7
5.86
98.9
48.5
6.65
95.3
47.3
7.51
91.0
45.9
8.43
86.2
44.1
9.38

67
96.9
63.6
5.07
93.6
62.4
5.79
90.1
61.2
6.58
86.2
59.6
7.44
82.0
58.0
8.33
77.8
56.4
9.29

62
87.6
75.7
5.04
83.6
73.9
5.73
79.3
71.9
6.49
75.7
70.2
7.31
71.6
68.1
8.20
68.1
66.3
9.14

3750/0.14
72
110.3
58.0
5.20
107.7
57.3
5.93
103.8
56.2
6.72
100.0
55.3
7.59
95.6
54.2
8.52
90.0
52.1
9.47

67
101.9
76.6
5.13
99.0
75.9
5.86
95.3
74.9
6.64
91.0
73.6
7.50
86.6
72.1
8.42
81.9
70.1
9.38

62
93.8
92.2
5.07
90.6
90.0
5.78
87.4
87.3
6.57
84.1
84.1
7.41
80.7
80.7
8.34
77.2
77.2
9.32

50HJ008 (71/2 TONS) HOT GAS REHEAT MODE*


75 Dry Bulb
62.5 Wet Bulb
(50% Relative)

Temp (F)
Air Ent
Condenser
(Edb)

80
75
70
60
50

50HJ

40

TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW

2250
37.74
10.67
4.92
37.34
9.83
5.19
36.93
8.99
5.46
36.13
7.31
5.99
35.32
5.63
6.52
34.52
3.94
7.05

3000
40.54
15.63
4.92
39.95
14.48
5.19
39.36
13.33
5.46
38.18
11.04
5.99
37.00
8.74
6.52
35.82
6.44
7.05

3750
42.68
19.63
4.92
41.95
18.24
5.19
41.22
16.84
5.46
39.75
14.04
5.99
38.29
11.25
6.52
36.82
8.45
7.05

Air Entering Evaporator Ewb (F)


75 Dry Bulb
64 Wet Bulb
(55% Relative)
Air Entering Evaporator Cfm
2250
3000
3750
38.48
41.35
43.55
5.01
9.84
13.74
4.97
4.97
4.97
38.08
40.75
42.81
4.52
9.05
12.70
5.25
5.25
5.25
37.67
40.16
42.07
4.02
8.26
11.67
5.52
5.52
5.52
36.87
38.97
40.58
3.04
6.67
9.60
6.08
6.08
6.08
36.06
37.78
39.10
2.06
5.09
7.53
6.63
6.63
6.63
35.26
36.60
37.62
1.08
3.51
5.47
7.18
7.18
7.18

LEGEND
BF
Bypass Factor
Edb Entering Dry Bulb
Ewb Entering Wet Bulb
kW Compressor Motor Power Input
SHC Sensible Heat Capacity (1000 Btuh) Gross
TC
Total Capacity (1000 Btuh) Gross
*Negative SHC value indicates that the air entering the coil is being
heated.
NOTES:
1. Direct interpolation is permissible. Do not extrapolate.

168

75 Dry Bulb
65.3 Wet Bulb
(60% Relative)
2250
39.12
0.10
5.01
38.72
-0.09
5.30
38.31
-0.28
5.58
37.51
-0.66
6.15
36.75
-1.03
6.73
35.90
-1.41
7.30

3000
42.05
4.82
5.01
41.45
4.34
5.30
40.85
3.86
5.58
39.66
2.89
6.15
38.46
1.93
6.73
37.27
0.97
7.30

3750
44.29
8.63
5.01
43.55
7.91
5.30
42.80
7.19
5.58
41.31
5.75
6.15
39.81
4.32
6.73
38.32
2.88
7.30

2. The following formulas may be used:


sensible capacity (Btuh)
tldb = tedb
1.10 x cfm
tlwb = Wet-bulb temperature corresponding to enthalpy of air
leaving evaporator coil (hlwb)
hlwb = hewb

total capacity (Btuh)


4.5 x cfm

Where: hewb = Enthalpy of air entering evaporator coil.


3. The SHC is based on 80 F edb temperature of air entering evaporator coil.
Below 80 F edb, subtract (corr factor x cfm) from SHC.
Above 80 F edb, add (corr factor x cfm) to SHC.
Correction Factor = 1.10 x (1 BF) x (edb 80).

COOLING CAPACITIES UNITS WITH HUMIDI-MIZER ADAPTIVE DEHUMIDIFICATION SYSTEM OPTION (cont)
50HJ009 (81/2 TONS) SUBCOOLING MODE
Temp (F)
Air Ent
Condenser
(Edb)
75
85
95
105
115
125

TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW

2550/0.08
72
114.1
49.8
5.57
107.3
42.2
6.32
101.9
35.4
7.06
94.5
29.7
7.99
86.4
24.0
8.91
78.6
18.3
9.81

67
104.1
64.2
5.46
98.4
58.3
6.30
92.4
51.9
7.13
85.4
45.7
8.00
75.0
38.7
8.83
65.5
32.0
9.65

62
97.8
81.2
5.44
92.6
76.0
6.15
86.8
70.3
6.93
77.0
63.2
7.81
68.3
56.4
8.66
60.2
48.8
9.53

72
116.3
52.6
5.59
111.0
47.1
6.32
105.3
40.1
7.06
97.6
33.9
8.01
89.3
27.4
8.93
81.3
21.2
9.86

Air Entering Evaporator Cfm/BF


3000/0.09
3400/0.11
Air Entering Evaporator Ewb (F)
67
62
72
67
108.5
103.4
117.6
111.9
70.8
89.0
55.4
76.9
5.50
5.44
5.60
5.51
101.8
98.0
113.0
104.2
64.5
83.5
51.2
70.2
6.27
6.18
6.34
6.22
95.5
92.8
107.4
97.7
58.5
77.9
44.9
64.9
7.06
6.95
7.06
6.99
88.3
82.4
99.9
90.6
52.2
70.1
38.0
58.3
7.97
7.85
8.02
7.94
80.2
74.1
91.4
83.2
45.6
62.9
31.1
51.9
8.86
8.76
8.97
8.86
68.9
64.7
83.3
71.6
38.0
53.5
24.1
44.1
9.68
9.64
9.89
9.71

4250/0.13
62
108.0
95.4
5.44
102.0
89.2
6.20
96.5
83.7
6.98
88.0
75.7
7.89
78.4
67.0
8.84
68.2
57.5
9.75

72
122.2
62.0
5.62
117.1
57.3
6.30
112.1
52.1
7.01
104.1
44.4
7.96
96.5
37.0
8.91
88.5
29.4
9.90

67
118.9
87.0
5.62
111.4
81.2
6.31
103.7
74.0
7.04
96.1
67.6
7.96
88.4
60.8
8.93
78.8
53.3
9.72

62
111.4
107.2
5.69
106.1
101.2
6.45
100.3
94.8
7.17
94.0
88.5
8.08
87.1
81.8
8.90
78.9
73.8
9.88

50HJ009 (81/2 TONS) HOT GAS REHEAT MODE


75 Dry Bulb
62.5 Wet Bulb
(50% Relative)

Temp (F)
Air Ent
Condenser
(Edb)
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW

80
75
70
60
50
40

3000
46.26
16.78
6.31
47.00
17.12
6.38
47.73
17.47
6.46
49.19
18.15
6.60
50.66
18.83
6.74
52.13
19.52
6.88

3400
48.45
20.29
6.31
49.06
20.44
6.8
49.68
20.59
6.46
50.90
20.90
6.60
52.13
21.20
6.74
53.35
21.51
6.88

4250
52.38
26.74
6.31
52.78
26.54
6.38
53.18
26.34
6.46
53.97
25.95
6.60
54.77
25.56
6.74
55.56
25.16
6.88

LEGEND
Bypass Factor
Entering Dry Bulb
Entering Wet Bulb
Compressor Motor Power Input
Sensible Heat Capacity (1000 Btuh) Gross
Total Capacity (1000 Btuh) Gross

NOTES:
1. Direct interpolation is permissible. Do not extrapolate.

75 Dry Bulb
65.3 Wet Bulb
(60% Relative)
2550
46.84
0.11
5.83
47.67
1.51
5.95
48.51
2.92
6.07
50.18
5.73
6.32
51.85
8.55
6.56
53.53
11.36
6.81

3000
49.79
4.40
5.83
50.46
5.58
5.95
51.14
6.76
6.07
52.49
9.11
6.32
53.83
11.47
6.56
55.18
13.82
6.81

3400
52.08
7.80
5.83
52.63
8.79
5.95
53.18
9.79
6.07
54.27
11.78
6.32
55.37
13.77
6.56
56.47
15.76
6.81

4250
56.20
14.03
5.83
56.52
14.70
5.95
56.84
15.36
6.07
57.49
16.68
6.32
58.14
18.01
6.56
58.78
19.33
6.81

2. The following formulas may be used:


sensible capacity (Btuh)
tldb = tedb
1.10 x cfm
tlwb = Wet-bulb temperature corresponding to enthalpy of air
leaving evaporator coil (hlwb)
hlwb = hewb

total capacity (Btuh)


4.5 x cfm

Where: hewb = Enthalpy of air entering evaporator coil.


3. The SHC is based on 80 F edb temperature of air entering evaporator coil.
Below 80 F edb, subtract (corr factor x cfm) from SHC.
Above 80 F edb, add (corr factor x cfm) to SHC.
Correction Factor = 1.10 x (1 BF) x (edb 80).

169

50HJ

BF
Edb
Ewb
kW
SHC
TC

2550
43.44
12.34
6.31
44.33
12.92
6.38
45.22
13.50
6.46
46.99
14.67
6.60
48.77
15.83
6.74
50.54
17.00
6.88

Air Entering Evaporator Ewb (F)


75 Dry Bulb
64 Wet Bulb
(55% Relative)
Air Entering Evaporator Cfm
2550
3000
3400
4250
45.26
48.15
50.39
54.43
5.79
10.15
13.60
19.93
6.05
6.05
6.05
6.05
46.12
48.85
50.97
54.78
6.81
10.94
14.20
20.20
6.15
6.15
6.15
6.15
46.98
49.55
51.55
55.14
7.83
11.73
14.81
20.46
6.25
6.25
6.25
6.25
48.70
50.96
52.71
55.86
9.88
13.31
16.01
20.99
6.45
6.45
6.45
6.45
50.42
52.36
53.87
56.57
11.93
14.89
17.22
21.51
6.64
6.64
6.64
6.64
52.14
53.76
55.02
57.29
13.98
16.47
18.43
22.04
6.84
6.84
6.84
6.84

Performance data 50HJ (cont)


COOLING CAPACITIES UNITS WITH HUMIDI-MIZER ADAPTIVE DEHUMIDIFICATION SYSTEM OPTION (cont)
50HJ012 (10 TONS) SUBCOOLING MODE
Temp (F)
Air Ent
Condenser
(Edb)
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW

75
85
95
105
115
125

3000/0.03
72
134.3
60.0
7.03
127.6
51.5
7.96
120.9
43.0
8.88
112.0
36.1
10.0
103.0
29.2
11.2
94.1
22.3
12.35

67
122.5
76.1
6.84
115.4
68.8
7.86
108.3
61.5
8.87
99.9
54.1
10.0
91.5
46.7
11.1
83.1
39.3
12.15

62
111.4
93.7
6.72
104.6
87.2
7.59
97.8
80.6
8.46
90.4
73.8
9.6
83.1
66.9
10.8
75.7
60.1
11.94

72
135.8
61.3
7.01
128.9
53.9
7.94
121.9
46.5
8.86
113.1
38.8
10.0
104.3
31.2
11.2
95.5
23.5
12.38

Air Entering Evaporator Cfm/BF


3200/0.03
4000/0.04
Air Entering Evaporator Ewb (F)
67
62
72
67
124.3
113.0
138.4
129.5
79.1
97.4
68.0
89.5
6.89
6.77
7.10
6.92
118.1
107.0
132.5
121.5
72.0
91.2
61.0
82.7
7.78
7.51
8.02
7.84
111.8
101.0
126.5
113.4
64.8
84.9
53.9
75.9
8.66
8.26
8.94
8.76
103.2
93.4
117.2
105.0
57.8
78.9
45.6
68.2
9.8
9.5
10.1
9.9
94.6
85.9
107.8
96.7
50.7
72.9
37.3
60.6
11.0
10.7
11.3
11.1
86.0
78.3
98.5
88.3
43.7
66.8
29.0
52.9
12.13
11.92
12.48
12.27

5000/0.04
62
123.5
109.4
6.77
116.6
102.4
7.69
109.7
95.4
8.60
100.7
86.8
9.8
91.7
78.3
11.0
82.7
69.7
12.25

72
143.3
75.2
7.15
137.2
68.6
8.02
131.1
62.0
8.89
122.1
53.0
10.1
113.0
44.0
11.3
104.0
35.0
12.53

67
136.5
100.9
7.03
128.0
93.6
7.94
119.4
86.2
8.85
110.5
78.3
10.0
101.6
70.3
11.2
92.7
62.4
12.30

62
130.2
123.3
6.88
122.9
115.9
7.79
115.5
108.4
8.69
105.9
99.7
9.9
96.4
90.9
11.1
86.8
82.2
12.28

50HJ012 (10 TONS) HOT GAS REHEAT MODE*


Air Entering Evaporator Ewb (F)
75 Dry Bulb
62.5 Wet Bulb
(50% Relative)

Temp (F)
Air Ent
Condenser
(Edb)
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW

80
75

70
60

50
40

50HJ

BF
Edb
Ewb
kW
SHC
TC

3000
49.15
9.58
7.39
49.60
10.07
7.56
50.04
10.56
7.73
50.93
11.54
8.07
51.82
12.53
8.42
52.71
13.51
8.76

3200
50.16
12.02
7.38
50.61
12.38
7.56
51.07
12.73
7.73
51.98
13.44
8.07
52.90
14.14
8.42
53.81
14.85
8.76

4000
53.80
20.74
7.38
54.30
20.60
7.55
54.81
20.47
7.72
55.81
20.19
8.07
56.81
19.92
8.41
57.82
19.64
8.76

5000
57.72
29.89
7.37
58.28
29.23
7.55
58.83
28.58
7.72
59.93
27.28
8.06
61.03
25.98
8.41
62.13
24.67
8.75

75 Dry Bulb
64 Wet Bulb
(55% Relative)
Air Entering Evaporator Cfm
3000
3200
4000
5000
51.04
52.08
55.86
59.94
2.88
5.29
13.88
22.89
7.45
7.45
7.44
7.43
51.45
52.50
56.33
60.45
3.82
6.09
14.20
22.70
7.63
7.63
7.62
7.62
51.86
52.92
56.80
60.96
4.75
6.89
14.52
22.52
7.81
7.81
7.81
7.80
52.68
53.77
57.73
61.99
6.62
8.49
15.16
22.15
8.18
8.18
8.17
8.17
53.50
54.62
58.66
63.01
8.50
10.09
15.80
21.78
8.54
8.54
8.54
8.54
54.32
55.46
59.59
64.04
10.37
11.70
16.43
21.41
8.91
8.91
8.91
8.90

LEGEND
Bypass Factor
Entering Dry Bulb
Entering Wet Bulb
Compressor Motor Power Input
Sensible Heat Capacity (1000 Btuh) Gross
Total Capacity (1000 Btuh) Gross

*Negative SHC value indicates that the air entering the coil is being heated.
NOTES:
1. Direct interpolation is permissible. Do not extrapolate.

170

75 Dry Bulb
65.3 Wet Bulb
(60% Relative)
3000
52.67
-2.92
7.50
53.05
-1.60
7.69
53.43
-0.28
7.89
54.20
2.36
8.27
54.96
5.00
8.66
55.72
7.64
9.04

3200
53.74
-0.55
7.50
54.14
0.64
7.69
54.53
1.83
7.88
55.32
4.21
8.27
56.10
6.58
8.65
56.89
8.96
9.04

4000
57.65
7.93
7.49
58.09
8.65
7.69
58.52
9.36
7.88
59.39
10.79
8.26
60.26
12.22
8.65
61.13
13.65
9.04

5000
61.86
16.83
7.49
62.34
17.05
7.68
62.82
17.26
7.87
63.77
17.70
8.26
64.73
18.14
8.65
65.69
18.58
9.03

2. The following formulas may be used:


sensible capacity (Btuh)
tldb = tedb
1.10 x cfm
tlwb

= Wet-bulb temperature corresponding to enthalpy of air


leaving evaporator coil (hlwb)

hlwb = hewb

total capacity (Btuh)


4.5 x cfm

Where: hewb = Enthalpy of air entering evaporator coil.


3. The SHC is based on 80 F edb temperature of air entering evaporator
coil.
Below 80 F edb, subtract (corr factor x cfm) from SHC.
Above 80 F edb, add (corr factor x cfm) to SHC.
Correction Factor = 1.10 x (1 BF) x (edb 80).

COOLING CAPACITIES UNITS WITH HUMIDI-MIZER ADAPTIVE DEHUMIDIFICATION SYSTEM OPTION (cont)
50HJ014 (121/2 TONS) SUBCOOLING MODE
Temp (F)
Air Ent
Condenser
(Edb)
75
85
95
105
115
125

TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW

3750/0.08
72
156.3
66.6
9.28
147.6
58.7
10.29
138.9
50.8
11.29
129.1
42.1
12.59
119.2
33.5
13.90
109.4
24.8
15.20

67
144.2
87.6
8.98
136.2
80.0
9.93
128.2
72.3
10.87
117.8
63.5
12.14
107.3
54.8
13.40
96.9
46.0
14.67

62
132.3
112.1
8.59
123.7
103.8
9.58
115.1
95.5
10.57
105.8
86.5
11.82
96.4
77.5
13.08
87.1
68.5
14.33

72
160.0
72.5
9.35
150.7
63.5
10.36
141.4
54.4
11.37
131.7
45.4
12.67
122.1
36.4
13.98
112.4
27.4
15.28

Air Entering Evaporator Cfm/BF


4300/0.09
5000/0.11
Air Entering Evaporator Ewb (F)
67
62
72
67
148.4
136.2
162.8
150.6
94.8
121.3
76.9
99.6
9.08
8.80
9.40
9.18
140.1
127.2
154.1
140.8
86.5
112.2
68.7
91.0
10.08
9.77
10.40
10.34
131.8
118.3
145.3
131.0
78.1
103.2
60.5
82.3
11.08
10.74
11.40
11.50
121.0
108.7
134.8
119.9
69.0
93.9
51.2
74.2
12.34
11.96
12.70
12.67
110.2
99.0
124.2
108.8
59.8
84.7
41.9
66.1
13.59
13.18
14.00
13.83
99.4
89.3
113.7
97.7
50.7
75.5
32.6
58.0
14.85
14.40
15.30
15.00

6250/0.13
62
138.2
127.5
8.9
127.9
118.1
10.03
117.6
108.7
11.1
107.7
101.3
12.28
97.8
93.8
13.41
87.8
86.4
14.54

72
169.0
87.0
9.43
161.1
77.7
10.45
153.1
68.5
11.46
140.9
57.7
12.79
128.7
46.8
14.11
116.5
36.0
15.44

67
157.5
115.5
9.18
148.0
107.8
10.18
138.4
100.0
11.17
126.9
90.2
12.46
115.3
80.5
13.75
103.8
70.7
15.04

62
145.6
142.7
8.93
135.4
133.2
9.88
125.1
123.7
10.83
115.9
113.6
12.08
106.7
103.5
13.33
97.5
93.5
14.58

50HJ014 (121/2 TONS) HOT GAS REHEAT MODE*


75 Dry Bulb
62.5 Wet Bulb
(50% Relative)

Temp (F)
Air Ent
Condenser
(Edb)

80
75
70
60
50
40

TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW

3750
43.54
-4.36
8.70
44.45
-3.84
8.90
45.36
-3.32
9.10
47.17
-2.28
9.51
48.98
-1.24
9.91
50.79
-0.20
10.31

4300
45.21
0.76
8.70
46.02
0.96
8.90
46.82
1.17
9.10
48.44
1.59
9.51
50.05
2.00
9.91
51.67
2.41
10.31

5000
47.05
6.50
8.70
47.75
6.36
8.90
48.45
6.21
9.10
49.84
5.93
9.51
51.24
5.64
9.91
52.64
5.35
10.31

6250
49.78
15.20
8.70
50.32
14.53
8.90
50.86
13.85
9.10
51.93
12.50
9.51
53.00
11.15
9.91
54.07
9.80
10.31

Air Entering Evaporator Ewb (F)


75 Dry Bulb
64 Wet Bulb
(55% Relative)
Air Entering Evaporator Cfm
3750
4300
5000
6250
45.46
47.16
49.05
51.85
-9.51
-4.35
1.45
10.22
8.82
8.82
8.82
8.82
46.33
47.94
49.71
52.34
-8.66
-3.81
1.63
9.86
9.03
9.03
9.03
9.03
47.20
48.71
50.37
52.84
-7.81
-3.28
1.80
9.50
9.24
9.24
9.24
9.24
48.95
50.25
51.69
53.83
-6.12
-2.22
2.16
8.79
9.66
9.66
9.66
9.66
50.70
51.80
53.01
54.82
-4.43
-1.15
2.52
8.07
10.09
10.09
10.09
10.09
52.44
53.34
54.33
55.80
-2.73
-.019
2.87
7.36
10.51
10.51
10.51
10.51

3750
47.11
-13.97
8.92
47.96
-12.84
9.14
48.80
-11.71
9.36
50.49
-9.45
9.80
52.18
-7.18
10.24
53.87
-4.92
10.68

4300
48.86
-8.77
8.92
49.60
-7.96
9.14
50.34
-7.14
9.36
51.82
-5.52
9.80
53.31
-3.89
10.24
54.79
-2.26
10.68

5000
50.78
-2.93
8.92
51.41
-2.48
9.14
52.04
-2.02
9.36
53.29
-1.11
9.80
54.55
-0.19
10.24
55.80
0.72
10.68

6250
53.64
5.90
8.92
54.10
5.82
9.14
54.55
5.74
9.36
55.47
5.57
9.80
56.39
5.41
10.24
57.30
5.24
10.68

2. The following formulas may be used:


sensible capacity (Btuh)
tldb = tedb
1.10 x cfm
tlwb = Wet-bulb temperature corresponding to enthalpy of air
leaving evaporator coil (hlwb)
hlwb = hewb

total capacity (Btuh)


4.5 x cfm

Where: hewb = Enthalpy of air entering evaporator coil.


3. The SHC is based on 80 F edb temperature of air entering evaporator coil.
Below 80 F edb, subtract (corr factor x cfm) from SHC.
Above 80 F edb, add (corr factor x cfm) to SHC.
Correction Factor = 1.10 x (1 BF) x (edb 80).

171

50HJ

LEGEND
BF
Bypass Factor
Edb Entering Dry Bulb
Ewb Entering Wet Bulb
kW Compressor Motor Power Input
SHC Sensible Heat Capacity (1000 Btuh) Gross
TC
Total Capacity (1000 Btuh) Gross
*Negative SHC value indicates that the air entering the coil is being
heated.
NOTES:
1. Direct interpolation is permissible. Do not extrapolate.

75 Dry Bulb
65.3 Wet Bulb
(60% Relative)

Performance data 50HJ (cont)


COOLING CAPACITIES, UNITS WITH MOISTUREMI$ER OPTION
50HJ015 (12 TONS)
Temp (F)
Air Entering
Condenser
(Edb)
75

85

95

105

115

117

120

125

TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW

3600/0.01
62

121
96
12.3
105
81
13.7
105
79
13.8
104
80
14.5
97
74
15.1

67
159
97
9.3
153
90
10.4
146
85
11.6
138
80
12.8
127
71
14.2
123
67
14.3
120
65
14.9
113
59
15.5

4375/0.01
72
180
78
9.8
168
72
10.9
161
67
12.0
154
62
13.3
145
55
14.6
145
53
15.0
141
51
15.3
137
48
16.2

62
151
131
9.2
145
126
10.4
139
119
11.3
129
111
12.6
114
96
13.8
110
94
14.2
107
88
14.5
101
83
15.1

67
166
110
9.7
159
103
10.8
152
97
11.7
145
91
12.9
134
85
14.4
132
84
14.6
129
79
15.1
118
69
15.6

Evaporator Air Quantity Cfm/BF


5000/0.01
Evaporator Air Ewb (F)
72
62
67
72
62
181
157
170
188
161
85
143
117
89
154
9.8
9.2
9.5
10.0
9.4
175
151
162
178
155
79
138
112
84
149
11.1
10.4
10.7
11.0
10.3
166
145
156
172
148
74
132
107
80
142
12.2
11.6
11.8
12.3
11.7
161
133
149
164
137
68
123
101
56
133
13.5
12.7
13.0
13.3
12.8
151
116
139
155
121
63
103
93
67
114
14.9
14.0
14.7
15.1
14.2
150
114
137
154
120
60
105
123
67
115
15.3
14.3
14.7
15.4
14.1
147
110
134
152
114
57
99
88
64
107
15.5
14.6
15.2
15.6
14.6
142
105
127
146
109
54
94
82
60
101
16.3
15.3
15.9
16.4
15.2

5625/0.02
67
173
127
9.7
166
121
10.7
160
116
12.0
151
109
13.0
142
102
14.8
141
101
14.9
138
97
15.2
131
92
16.1

6250/0.02
72
193
97
10.0
182
90
11.2
174
85
12.3
165
80
13.6
158
72
15.2
156
70
15.4
154
68
15.9
148
64
16.5

62
171
170
9.7
160
158
10.8
152
149
11.6
144
141
12.9
131
126
14.4
129
125
14.5
123
116
15.0
113
105
15.5

67
176
135
9.8
169
129
10.9
163
125
12.0
154
118
13.3
145
111
14.8
143
111
14.9
142
105
15.4
136
100
16.1

72
192
101
10.1
184
96
11.4
176
89
12.3
168
85
13.7
160
78
15.2
158
77
15.4
156
73
15.9
150
71
16.6

50HJ017 (15 TONS)


Temp (F)
Air Entering
Condenser
(Edb)
75

85

95

105

115

118

50HJ

120

BF
Edb
Ewb
kW
ldb
lwb
SHC
TC

TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW

4500/0.02
62

67
185
105
11.3
176
98
12.3
168
91
13.7
156
83
14.5
141
72
15.6
138
68
16.1
134
65
16.2

5250/0.03
72
203
82
11.7
193
74
12.7
182
66
13.5
173
59
15.3
156
47
15.9
151
43
16.5

62
175
141
11.0
166
134
12.1
156
126
13.1
145
117
14.2
130
104
15.2
126
100
15.7
124
99
15.9

67
191
115
11.4
183
108
12.9
173
100
13.6
160
90
14.8
146
79
15.8
141
74
16.1

72
209
88
11.8
199
81
13.4
187
72
13.9
175
62
15.1
160
52
16.2
153
46
16.5

Evaporator Air Quantity Cfm/BF


6000/0.04
Evaporator Air Ewb (F)
62
67
72
62
179
195
212
182
154
125
96
165
11.1
11.5
11.9
11.2
170
186
202
173
145
116
85
156
12.1
12.6
13.5
12.2
160
176
191
163
137
108
76
146
13.2
13.6
14.1
13.3
148
162
177
151
127
98
66
136
14.4
14.5
15.1
14.4
132
150
162
135
112
86
55
119
15.3
16.1
16.3
15.4
129
144

134
108
83

120
15.8
16.3

16.0
126

106

16.0

LEGEND
Bypass Factor
Entering Dry-Bulb
Entering Wet-Bulb
Compressor Motor Power Input
Leaving Dry-Bulb
Leaving Wet-Bulb
Sensible Heat Capacity (1000 Btuh) Gross
Total Capacity (1000 Btuh) Gross

NOTES:
1. Direct interpolation is permissible. Do not extrapolate.
2. The following formulas may be used:
sensible capacity (Btuh)
tldb = tedb
1.10 x cfm
tlwb = Wet-bulb temperature corresponding to enthalpy of air leaving evaporator coil (hlwb)
total capacity (Btuh)
hlwb = hewb
4.5 x cfm
Where: hewb = Enthalpy of air entering evaporator coil

172

6750/0.04
67
198
135
11.6
189
126
12.7
178
116
13.4
166
106
14.9
150
93
16.0
145
88
16.3

7500/0.05
72
213
104
11.9
204
93
13.5
194
82
14.3
178
70
14.9
164
59
16.4

62
186
174
11.3
177
162
12.7
167
153
13.5
154
141
14.2
139
127
15.8
135
124
15.9

67
200
145
11.7
190
134
12.2
181
125
13.9
167
112
14.6
152
100
16.1
148
96
16.3

72
216
109
12.0
205
97
12.7
196
86
14.6
180
74
14.9
166
63
16.4

3. The SHC is based on 80 F edb temperature of air entering evaporator coil.


Below 80 F edb, subtract (corr factor x cfm) from SHC.
Above 80 F edb, add (corr factor x cfm) to SHC.

BYPASS
FACTOR
(BF)

79
81

.05
.10
.20
.30

1.04
.98
.87
.76

ENTERING AIR DRY-BULB TEMP (F)


78
77
76
75
under 75
82
83
84
85
over 85
Correction Factor
2.07
3.11
4.14
5.18
Use formula
1.96
2.94
3.92
4.90
shown below.
1.74
2.62
3.49
4.36
1.53
2.29
3.05
3.82

Interpolation is permissible.
Correction Factor = 1.10 x (1 BF) x (edb 80).

GLYCOL HEATING PERFORMANCE


GLYCOL COIL (50HJ015,017)

Edb

Ewt
200
180
160
200
180
160
200
180
160

55

70

80

Air Entering Cfm


5400
Percent Glycol

4400

Temperature
Entering
Cap
310
255
200
274
218
164
249
194
140

25
Gpm
33
27
21
29
23
17
26
21
15

Ldb
120
108
97
127
116
104
132
121
109

Cap
293
237
181
257
201
146
233
177
123

50
Gpm
33
27
21
29
23
17
27
20
14

GLYCOL COIL (50HJ015,017) (cont)


Air Entering Cfm
Temperature
9000
Entering
25
50
Edb
Ewt
Cap
Gpm
Ldb
Cap
Gpm
200
453
48
102
425
48
55
180
371
39
93
342
39
160
290
31
85
260
30
200
400
42
111
372
42
70
180
317
34
103
287
33
160
237
25
94
208
24
200
364
39
118
337
38
80
180
281
30
109
254
29
160
201
21
101
173
20

Ldb
116
105
93
124
112
100
129
117
106

Cap
347
285
223
306
244
183
279
217
156

25
Gpm
37
30
24
32
26
19
30
23
16

Ldb
115
104
94
123
112
101
128
117
107

Cap
327
264
202
287
224
162
260
197
136

50
Gpm
37
30
23
33
26
19
30
23
16

7200

Ldb
111
101
90
119
109
98
125
114
103

Cap
405
332
259
357
284
212
325
252
180

25
Gpm
43
35
27
38
30
22
34
26
18

Ldb
107
98
89
116
107
97
122
113
103

Cap
381
306
233
333
259
187
302
228
156

50
Gpm
43
35
27
38
30
22
34
27
19

Ldb
104
95
85
113
104
94
119
109
100

Ldb
99
90
82
108
100
91
115
106
78

GLYCOL COIL RATINGS (50HJ015,017)


Entering
Fluid
Temp (F)
200
180
160
Cap
Edb
Ewt
Gpm
Ldb

4,000
Gpm
27
22
16

LEGEND
Btuh 1000
Entering Dry Bulb Temperature (F)
Entering Water Temperature (F)
Gallons Per Minute
Leaving Dry-Bulb Temperature (F)

Cfm
6,000

5,000
P*
1.2
0.9
0.6

Gpm
31
25
19

P*
1.5
1.1
0.7

Gpm
35
27
20

8,000
P*
1.8
1.3
0.8

Gpm
41
32
24

10,000
P*
2.4
1.6
1.0

Gpm
47
36
27

P*
2.9
2.0
1.2

NOTES:
1. This accessory glycol coil is intended for use with a MINIMUM of 25% glycol
solution. It IS NOT intended for use solely with water due to freeze-up conditions and the resulting water damage to the conditioned space.
2. Water = 20 F.

*P is the fluid pressure in ft of head.

50HJ
173

Performance data 50HJ (cont)


FAN PERFORMANCE VERTICAL DISCHARGE UNITS
50HJ004 (3 TONS) STANDARD MOTOR (BELT DRIVE)*
Airflow
(Cfm)
900
1000
1100
1200
1300
1400
1500

Rpm
566
598
632
666
701
737
774

0.2
Bhp
0.14
0.17
0.21
0.25
0.30
0.36
0.42

Watts
142
173
210
252
300
355
417

Rpm
690
718
748
778
809
842
875

0.4
Bhp
0.23
0.27
0.31
0.36
0.42
0.48
0.55

External Static Pressure (in. wg


0.6
Watts
Rpm
Bhp
Watts
Rpm
228
791
0.32
320
879
267
817
0.37
366
903
311
844
0.42
418
929
361
873
0.48
476
956
418
902
0.54
540
983
481
932
0.61
610
1012
551
962
0.69
689
1041

0.8

1.0

Bhp
0.42
0.47
0.53
0.60
0.67
0.75
0.83

Watts
418
471
530
594
665
744
830

Rpm
957
981
1006
1031
1057
1085
1112

Bhp
0.52
0.58
0.65
0.72
0.80
0.89
0.98

Watts
522
581
646
718
796
881
974

1.8
Bhp
0.99
1.07
1.16

Watts
980
1064
1154

Rpm
1272
1293

2.0
Bhp
1.11
1.20

Watts
1105
1195

50HJ004 (3 TONS) STANDARD MOTOR (BELT DRIVE)* (cont)


Airflow
(Cfm)
900
1000
1100
1200
1300
1400
1500
Bhp
Watts

Rpm
1029
1052
1076
1100
1126
1152
1179

1.2
Bhp
0.63
0.70
0.77
0.85
0.94
1.03
1.13

Watts
630
695
767
845
930
1023
1123

Rpm
1095
1118
1141
1165
1189
1215

1.4
Bhp
0.75
0.82
0.90
0.98
1.07
1.17

External Static Pressure (in. wg)


1.6
Watts
Rpm
Bhp
Watts
Rpm
742
1157
0.86
859
1216
814
1179
0.94
937
1237
892
1202
1.03
1021
1260
977
1225
1.12
1112

1069

1168

LEGEND
Brake Horsepower Input to Fan
Input Watts to Motor

NOTES:
1. Boldface indicates field-supplied drive is required.
2. Maximum continuous bhp is 1.20.
3. See page 187 for general fan performance notes.

*Motor drive range: 680 to 1044 rpm. All other rpms require field-supplied
drive.

50HJ004 (3 TONS) HIGH-STATIC MOTOR (BELT DRIVE)*


External Static Pressure (in. wg)
0.6
Watts
Rpm
Bhp
Watts
Rpm
228
791
0.32
320
879
267
817
0.37
366
903
311
844
0.42
418
929
361
873
0.48
476
956
418
902
0.54
540
983
481
932
0.61
610
1012
551
962
0.69
689
1041

0.8
Bhp
0.42
0.47
0.53
0.60
0.67
0.75
0.83

Watts
418
471
530
594
665
744
830

Rpm
957
981
1006
1031
1057
1085
1112

1.0
Bhp
0.52
0.58
0.65
0.72
0.80
0.89
0.98

Watts
522
581
646
718
796
881
974

50HJ004 (3 TONS) HIGH-STATIC MOTOR (BELT DRIVE)* (cont)


External Static Pressure (in. wg)
Airflow
1.2
1.4
1.6
(Cfm)
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
900
1029
0.63
630
1095
0.75
742
1157
0.86
859
1216
1000
1052
0.70
695
1118
0.82
814
1179
0.94
937
1237
1100
1076
0.77
767
1141
0.90
892
1202
1.03
1021
1260
1200
1100
0.85
845
1165
0.98
977
1225
1.12
1112
1282
1300
1126
0.94
930
1189
1.07
1069
1249
1.22
1211
1306
1400
1152
1.03
1023
1215
1.17
1168
1274
1.32
1317
1330
1500
1179
1.13
1123
1241
1.28
1275
1300
1.44
1431
1355

1.8
Bhp
0.99
1.07
1.16
1.26
1.36
1.48
1.60

Watts
980
1064
1154
1252
1356
1469
1590

Rpm
1272
1293
1314
1337
1360
1384
1408

2.0
Bhp
1.11
1.20
1.30
1.40
1.51
1.63
1.76

Watts
1105
1195
1291
1395
1506
1625
1752

Airflow
(Cfm)
900
1000
1100
1200
1300
1400
1500

50HJ

Bhp
Watts

Rpm
566
598
632
666
701
737
774

0.2
Bhp
0.14
0.17
0.21
0.25
0.30
0.36
0.42

Watts
142
173
210
252
300
355
417

Rpm
690
718
748
778
809
842
875

0.4
Bhp
0.23
0.27
0.31
0.36
0.42
0.48
0.55

LEGEND
Brake Horsepower Input to Fan
Input Watts to Motor

*Motor drive range: 1075 to 1455 rpm. All other rpms require field-supplied
drive.

174

NOTES:
1. Boldface indicates field-supplied drive is required.
2. Maximum continuous bhp is 2.40.
3. See page 187 for general fan performance notes.

FAN PERFORMANCE VERTICAL DISCHARGE UNITS (cont)


50HJ005 (4 TONS) STANDARD MOTOR (BELT DRIVE)*
Airflow
(Cfm)
1200
1300
1400
1500
1600
1700
1800
1900
2000

Rpm
666
701
737
774
811
849
887
926
965

0.2
Bhp
0.25
0.30
0.36
0.42
0.49
0.57
0.65
0.75
0.86

Watts
252
300
355
417
487
565
651
746
852

Rpm
778
809
842
875
909
943
978
1014
1050

0.4
Bhp
0.36
0.42
0.48
0.55
0.63
0.72
0.81
0.92
1.03

External Static Pressure (in. wg)


0.6
Watts
Rpm
Bhp
Watts
Rpm
361
873
0.48
476
956
418
902
0.54
540
983
481
932
0.61
610
1012
551
962
0.69
689
1041
629
994
0.78
774
1071
715
1026
0.87
869
1101
810
1059
0.98
972
1133
914
1092
1.09
1084

1028

0.8
Bhp
0.60
0.67
0.75
0.83
0.93
1.03
1.14

Watts
594
665
744
830
923
1025
1136

Rpm
1031
1057
1085
1112
1141
1170

1.0
Bhp
0.72
0.80
0.89
0.98
1.08
1.19

Watts
718
796
881
974
1076
1185

1.8
Bhp

Watts

Rpm

2.0
Bhp

Watts

50HJ005 (4 TONS) STANDARD MOTOR (BELT DRIVE)* (cont)


Airflow
(Cfm)
1200
1300
1400
1500
1600
1700
1800
1900
2000
Bhp
Watts

Rpm
1100
1126
1152
1179

1.2
Bhp
0.85
0.94
1.03
1.13

Watts
845
930
1023
1123

Rpm
1165
1189
1215

1.4
Bhp
0.98
1.07
1.17

External Static Pressure (in. wg)


1.6
Watts
Rpm
Bhp
Watts
Rpm
977
1225
1.12
1112

1069

1168

LEGEND
Brake Horsepower Input to Fan
Input Watts to Motor

NOTES:
1. Boldface indicates field-supplied drive is required.
2. Maximum continuous bhp is 1.20.
3. See page 187 for general fan performance notes.

*Motor drive range: 770 to 1185 rpm. All other rpms require field-supplied
drive.

50HJ005 (4 TONS) HIGH-STATIC MOTOR (BELT DRIVE)*


0.8
Bhp
0.60
0.67
0.75
0.83
0.93
1.03
1.14
1.26
1.39

Watts
594
665
744
830
923
1025
1136
1257
1387

Rpm
1031
1057
1085
1112
1141
1170
1200
1231
1262

1.0
Bhp
0.72
0.80
0.89
0.98
1.08
1.19
1.31
1.44
1.58

Watts
718
796
881
974
1076
1185
1304
1432
1570

50HJ005 (4 TONS) HIGH-STATIC MOTOR (BELT DRIVE)* (cont)


External Static Pressure (in. wg)
Airflow
1.2
1.4
1.6
(Cfm)
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
1200
1100
0.85
845
1165
0.98
977
1225
1.12
1112
1282
1300
1126
0.94
930
1189
1.07
1069
1249
1.22
1211
1306
1400
1152
1.03
1023
1215
1.17
1168
1274
1.32
1317
1330
1500
1179
1.13
1123
1241
1.28
1275
1300
1.44
1431
1355
1600
1206
1.24
1231
1268
1.40
1391
1326
1.56
1553
1381
1700
1235
1.36
1349
1295
1.52
1515
1352
1.69
1685
1407
1800
1264
1.48
1475
1323
1.66
1649
1380
1.84
1826
1434
1900
1293
1.62
1611
1352
1.80
1792
1408
1.99
1976
1461
2000
1324
1.77
1756
1381
1.96
1945
1436
2.15
2137
1489

1.8
Bhp
1.26
1.36
1.48
1.60
1.73
1.87
2.02
2.17
2.34

Watts
1252
1356
1469
1590
1719
1858
2006
2163
2332

Rpm
1337
1360
1384
1408
1433
1459
1485
1512

2.0
Bhp
1.40
1.51
1.63
1.76
1.90
2.04
2.20
2.37

Watts
1395
1506
1625
1752
1888
2034
2189
2353

1200
1300
1400
1500
1600
1700
1800
1900
2000

Bhp
Watts

Rpm
666
701
737
774
811
849
887
926
965

0.2
Bhp
0.25
0.30
0.36
0.42
0.49
0.57
0.65
0.75
0.86

Watts
252
300
355
417
487
565
651
746
852

Rpm
778
809
842
875
909
943
978
1014
1050

0.4
Bhp
0.36
0.42
0.48
0.55
0.63
0.72
0.81
0.92
1.03

LEGEND
Brake Horsepower Input to Fan
Input Watts to Motor

NOTES:
1. Boldface indicates field-supplied drive is required.
2. Maximum continuous bhp is 2.40.
3. See page 187 for general fan performance notes.

*Motor drive range: 1075 to 1455 rpm. All other rpms require field-supplied
drive.

175

50HJ

External Static Pressure (in. wg)


0.6
Watts
Rpm
Bhp
Watts
Rpm
361
873
0.48
476
956
418
902
0.54
540
983
481
932
0.61
610
1012
551
962
0.69
689
1041
629
994
0.78
774
1071
715
1026
0.87
869
1101
810
1059
0.98
972
1133
914
1092
1.09
1084
1164
1028
1127
1.21
1206
1197

Airflow
(Cfm)

Performance data 50HJ (cont)


FAN PERFORMANCE VERTICAL DISCHARGE UNITS (cont)
50HJ006 (5 TONS) STANDARD MOTOR (BELT DRIVE) SINGLE PHASE*
External Static Pressure (in. wg)
Airflow
0.2
0.4
0.6
(Cfm)
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
1500
790
0.40
353
897
0.53
471
991
0.68
600
1075
1600
828
0.46
412
931
0.60
536
1022
0.75
670
1104
1700
866
0.54
478
966
0.68
608
1054
0.84
747
1134
1800
905
0.62
551
1001
0.77
687
1087
0.94
832
1165
1900
944
0.71
633
1037
0.87
774
1120
1.04
925
1197
2000
983
0.81
723
1073
0.98
870
1154
1.16
1026

2100
1023
0.92
821
1110
1.10
975
1189
1.28
1137

2200
1063
1.05
929
1147
1.23
1089

2300
1104
1.18
1046

2400

2500

0.8
Bhp
0.83
0.92
1.01
1.11
1.22

Watts
739
813
895
985
1084

Rpm
1152
1180
1208
1238

1.0
Bhp
1.00
1.09
1.19
1.29

Watts
888
966
1053
1148

50HJ006 (5 TONS) STANDARD MOTOR (BELT DRIVE) SINGLE PHASE* (cont)


External Static Pressure (in. wg)
Airflow
1.2
1.4
1.6
(Cfm)
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
1500
1224
1.18
1045

1600
1250
1.27
1128

1700

1800

1900

2000

2100

2200

2300

2400

2500

1.8
Bhp

Watts

Rpm

2.0
Bhp

Watts

Bhp
Watts

LEGEND
Brake Horsepower Input to Fan
Input Watts to Motor

NOTES:
1. Boldface indicates field-supplied drive is required.
2. Maximum continuous bhp is 1.30.
3. See page 187 for general fan performance notes.

50HJ

*Motor drive range: 1035 to 1460 rpm. All other rpms require field-supplied
drive.

50HJ006 (5 TONS) STANDARD MOTOR (BELT DRIVE) THREE PHASE*


External Static Pressure (in. wg)
Airflow
0.2
0.4
0.6
(Cfm)
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
1500
790
0.40
353
897
0.53
471
991
0.68
600
1075
1600
828
0.46
412
931
0.60
536
1022
0.75
670
1104
1700
866
0.54
478
966
0.68
608
1054
0.84
747
1134
1800
905
0.62
551
1001
0.77
687
1087
0.94
832
1165
1900
944
0.71
633
1037
0.87
774
1120
1.04
925
1197
2000
983
0.81
723
1073
0.98
870
1154
1.16
1026
1229
2100
1023
0.92
821
1110
1.10
975
1189
1.28
1137
1262
2200
1063
1.05
929
1147
1.23
1089
1224
1.41
1256
1295
2300
1104
1.18
1046
1185
1.37
1212
1260
1.56
1386
1329
2400
1145
1.32
1174
1223
1.52
1346
1296
1.72
1526
1364
2500
1185
1.48
1311
1262
1.68
1490
1333
1.89
1676
1399

0.8
Bhp
0.83
0.92
1.01
1.11
1.22
1.34
1.47
1.61
1.76
1.93
2.10

Watts
739
813
895
985
1084
1190
1306
1431
1567
1712
1868

Rpm
1152
1180
1208
1238
1268
1299
1330
1362
1395
1428
1462

1.0
Bhp
1.00
1.09
1.19
1.29
1.41
1.53
1.67
1.82
1.98
2.15
2.33

Watts
888
966
1053
1148
1251
1362
1483
1614
1754
1905
2067

50HJ006 (5 TONS) STANDARD MOTOR (BELT DRIVE) THREE PHASE* (cont)


External Static Pressure (in. wg)
Airflow
1.2
1.4
1.6
(Cfm)
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
1500
1224
1.18
1045
1291
1.36
1212
1354
1.56
1387
1414
1600
1250
1.27
1128
1316
1.46
1299
1379
1.66
1478
1438
1700
1278
1.37
1219
1343
1.57
1394
1405
1.77
1576
1463
1800
1306
1.48
1318
1370
1.69
1497
1431
1.90
1683
1489
1900
1335
1.61
1426
1398
1.81
1609
1458
2.03
1799
1515
2000
1364
1.74
1542
1427
1.95
1730
1486
2.17
1925
1542
2100
1395
1.88
1668
1456
2.09
1860
1514
2.32
2060

2200
1426
2.03
1804
1486
2.25
2001

2300
1457
2.19
1949

2400
1489
2.37
2106

2500

1.8
Bhp
1.77
1.87
1.99
2.11
2.25
2.39

Watts
1570
1664
1766
1877
1997
2126

Rpm
1472
1495
1520
1545

2.0
Bhp
1.98
2.09
2.21
2.34

Watts
1761
1858
1964
2078

LEGEND
Bhp
Brake Horsepower Input to Fan
Watts Input Watts to Motor
*Motor drive range: 1035 to 1460 rpm. All other rpms require field-supplied
drive.

176

NOTES:
1. Boldface indicates field-supplied drive is required.
2. Maximum continuous bhp is 2.40.
3. See page 187 for general fan performance notes.

FAN PERFORMANCE VERTICAL DISCHARGE UNITS (cont)


50HJ006 (5 TONS) HIGH-STATIC MOTOR (BELT DRIVE)*
External Static Pressure (in. wg)
0.6
Watts
Rpm
Bhp
Watts
Rpm
471
991
0.68
600
1075
536
1022
0.75
670
1104
608
1054
0.84
747
1134
687
1087
0.94
832
1165
774
1120
1.04
925
1197
870
1154
1.16
1026
1229
975
1189
1.28
1137
1262
1089
1224
1.41
1256
1295
1212
1260
1.56
1386
1329
1346
1296
1.72
1526
1364
1490
1333
1.89
1676
1399

0.8
Bhp
0.83
0.92
1.01
1.11
1.22
1.34
1.47
1.61
1.76
1.93
2.10

Watts
739
813
895
985
1084
1190
1306
1431
1567
1712
1868

Rpm
1152
1180
1208
1238
1268
1299
1330
1362
1395
1428
1462

1.0
Bhp
1.00
1.09
1.19
1.29
1.41
1.53
1.67
1.82
1.98
2.15
2.33

Watts
888
966
1053
1148
1251
1362
1483
1614
1754
1905
2067

50HJ006 (5 TONS) HIGH-STATIC MOTOR (BELT DRIVE)* (cont)


External Static Pressure (in. wg)
Airflow
1.2
1.4
1.6
(Cfm)
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
1500
1224
1.18
1045
1291
1.36
1212
1354
1.56
1387
1414
1600
1250
1.27
1128
1316
1.46
1299
1379
1.66
1478
1438
1700
1278
1.37
1219
1343
1.57
1394
1405
1.77
1576
1463
1800
1306
1.48
1318
1370
1.69
1497
1431
1.90
1683
1489
1900
1335
1.61
1426
1398
1.81
1609
1458
2.03
1799
1515
2000
1364
1.74
1542
1427
1.95
1730
1486
2.17
1925
1542
2100
1395
1.88
1668
1456
2.09
1860
1514
2.32
2060
1570
2200
1426
2.03
1804
1486
2.25
2001
1543
2.48
2204
1598
2300
1457
2.19
1949
1516
2.42
2151
1573
2.66
2360
1627
2400
1489
2.37
2106
1547
2.60
2312
1603
2.84
2526

2500
1522
2.56
2272
1579
2.80
2484

1.8
Bhp
1.77
1.87
1.99
2.11
2.25
2.39
2.55
2.72
2.90

Watts
1570
1664
1766
1877
1997
2126
2265
2415
2574

Rpm
1472
1495
1520
1545
1570
1596
1623

2.0
Bhp
1.98
2.09
2.21
2.34
2.48
2.63
2.79

Watts
1761
1858
1964
2078
2202
2335
2478

Airflow
(Cfm)
1500
1600
1700
1800
1900
2000
2100
2200
2300
2400
2500

Bhp
Watts

Rpm
790
828
866
905
944
983
1023
1063
1104
1145
1185

0.2
Bhp
0.40
0.46
0.54
0.62
0.71
0.81
0.92
1.05
1.18
1.32
1.48

Watts
353
412
478
551
633
723
821
929
1046
1174
1311

Rpm
897
931
966
1001
1037
1073
1110
1147
1185
1223
1262

0.4
Bhp
0.53
0.60
0.68
0.77
0.87
0.98
1.10
1.23
1.37
1.52
1.68

LEGEND
Brake Horsepower Input to Fan
Input Watts to Motor

*Motor drive range: 1300 to 1685 rpm. All other rpms require field-supplied
drive.

NOTES:
1. Boldface indicates field-supplied drive is required.
2. Maximum continuous bhp is 2.90.
3. See page 187 for general fan performance notes.

50HJ007 (6 TONS) STANDARD MOTOR (BELT DRIVE)*


Airflow
(Cfm)
1800
1900
2000
2100
2200
2300
2400
2500
2600
2700
2800
2900
3000

Rpm
907
945
984
1024
1063
1103
1143
1183
1224
1264
1305
1346

0.2
Bhp
0.63
0.72
0.82
0.93
1.05
1.18
1.32
1.47
1.63
1.81
1.99
2.20

Watts
558
638
727
823
929
1044
1168
1303
1448
1604
1772
1951

Rpm
1006
1042
1078
1115
1152
1189
1227
1265
1303
1342
1381

0.4
Bhp
0.80
0.90
1.00
1.12
1.25
1.39
1.54
1.70
1.87
2.06
2.26

External Static Pressure (in. wg)


0.6
Watts
Rpm
Bhp
Watts
Rpm
708
1092
0.97
860
1169
796
1126
1.08
956
1201
892
1160
1.19
1060
1235
997
1195
1.32
1173
1268
1111
1230
1.46
1294
1302
1234
1266
1.60
1425
1337
1367
1302
1.76
1566
1371
1510
1339
1.93
1717
1406
1663
1375
2.12
1878
1442
1828
1412
2.31
2051

2003

0.8
Bhp
1.14
1.26
1.39
1.52
1.67
1.82
1.99
2.17
2.36

Watts
1015
1119
1230
1350
1480
1618
1767
1926
2095

Rpm
1239
1271
1303
1335
1368
1402
1435

1.0
Bhp
1.32
1.45
1.58
1.72
1.88
2.04
2.22

Watts
1174
1285
1403
1531
1668
1814
1970

1.8
Bhp
2.08
2.23
2.40

Watts
1848
1984
2130

Rpm
1528

2.0
Bhp
2.28

Watts
2025

50HJ007 (6 TONS) STANDARD MOTOR (BELT DRIVE)* (cont)

1800
1900
2000
2100
2200
2300
2400
2500
2600
2700
2800
2900
3000
Bhp
Watts

Rpm
1304
1335
1366
1398
1430
1462

1.2
Bhp
1.51
1.64
1.78
1.93
2.09
2.27

Watts
1337
1454
1580
1715
1858
2012

Rpm
1365
1395
1426
1457
1488

1.4
Bhp
1.69
1.83
1.98
2.14
2.31

External Static Pressure (in. wg)


1.6
Watts
Rpm
Bhp
Watts
Rpm
1503
1422
1.88
1674
1477
1627
1452
2.03
1804
1506
1760
1482
2.19
1943
1535
1901
1512
2.35
2091

2052

LEGEND
Brake Horsepower Input to Fan
Input Watts to Motor

*Motor drive range: 1120 to 1585 rpm. All other rpms require field-supplied
drive.

NOTES:
1. Boldface indicates field-supplied drive is required.
2. Maximum continuous bhp is 2.40.
3. See page 187 for general fan performance notes.

177

50HJ

50HJ

Airflow
(Cfm)

Performance data 50HJ (cont)


FAN PERFORMANCE VERTICAL DISCHARGE UNITS (cont)
50HJ007 (6 TONS) HIGH-STATIC MOTOR (BELT DRIVE)*
External Static Pressure (in. wg)
0.6
Watts
Rpm
Bhp
Watts
Rpm
708
1092
0.97
860
1169
796
1126
1.08
956
1201
892
1160
1.19
1060
1235
997
1195
1.32
1173
1268
1111
1230
1.46
1294
1302
1234
1266
1.60
1425
1337
1367
1302
1.76
1566
1371
1510
1339
1.93
1717
1406
1663
1375
2.12
1878
1442
1828
1412
2.31
2051
1478
2003
1450
2.52
2235
1514
2191
1488
2.74
2431

2391

0.8
Bhp
1.14
1.26
1.39
1.52
1.67
1.82
1.99
2.17
2.36
2.56
2.78

Watts
1015
1119
1230
1350
1480
1618
1767
1926
2095
2275
2467

Rpm
1239
1271
1303
1335
1368
1402
1435
1470
1504
1539

1.0
Bhp
1.32
1.45
1.58
1.72
1.88
2.04
2.22
2.41
2.60
2.82

Watts
1174
1285
1403
1531
1668
1814
1970
2136
2313
2501

50HJ007 (6 TONS) HIGH-STATIC MOTOR (BELT DRIVE)* (cont)


External Static Pressure (in. wg)
Airflow
1.2
1.4
1.6
(Cfm)
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
1800
1304
1.51
1337
1365
1.69
1503
1422
1.88
1674
1477
1900
1335
1.64
1454
1395
1.83
1627
1452
2.03
1804
1506
2000
1366
1.78
1580
1426
1.98
1760
1482
2.19
1943
1535
2100
1398
1.93
1715
1457
2.14
1901
1512
2.35
2091
1565
2200
1430
2.09
1858
1488
2.31
2052
1543
2.53
2249
1596
2300
1462
2.27
2012
1520
2.49
2212
1574
2.72
2416

2400
1495
2.45
2175
1552
2.68
2383

2500
1529
2.64
2349
1585
2.89
2564

2600
1562
2.85
2533

2700

2800

2900

3000

1.8
Bhp
2.08
2.23
2.40
2.57
2.76

Watts
1848
1984
2130
2284
2449

Rpm
1528
1557
1586
1616

2.0
Bhp
2.28
2.44
2.61
2.79

Watts
2025
2168
2319
2481

Airflow
(Cfm)
1800
1900
2000
2100
2200
2300
2400
2500
2600
2700
2800
2900
3000

Bhp
Watts

Rpm
907
945
984
1024
1063
1103
1143
1183
1224
1264
1305
1346
1387

0.2
Bhp
0.63
0.72
0.82
0.93
1.05
1.18
1.32
1.47
1.63
1.81
1.99
2.20
2.41

Watts
558
638
727
823
929
1044
1168
1303
1448
1604
1772
1951
2142

Rpm
1006
1042
1078
1115
1152
1189
1227
1265
1303
1342
1381
1420
1459

0.4
Bhp
0.80
0.90
1.00
1.12
1.25
1.39
1.54
1.70
1.87
2.06
2.26
2.47
2.69

LEGEND
Brake Horsepower Input to Fan
Input Watts to Motor

50HJ

*Motor drive range: 1300 to 1685 rpm. All other rpms require field-supplied
drive.

178

NOTES:
1. Boldface indicates field-supplied drive is required.
2. Maximum continuous bhp is 2.90.
3. See page 187 for general fan performance notes.

FAN PERFORMANCE VERTICAL DISCHARGE UNITS (cont)


50HJ008 (71/2 TONS) STANDARD MOTOR (BELT DRIVE)*
Airflow
(Cfm)
2250
2300
2400
2500
2550
2600
2700
2800
2900
3000
3100
3200
3300
3400
3500
3600
3700
3750

Rpm
511
519
534
550
558
565
581
597
613
630
646
663
679
696
713
729
746
755

0.2
Bhp
0.53
0.56
0.61
0.67
0.71
0.74
0.81
0.89
0.97
1.06
1.15
1.25
1.35
1.46
1.58
1.70
1.83
1.89

Watts
492
518
571
629
660
691
758
829
905
985
1071
1162
1259
1361
1469
1583
1703
1766

Rpm
591
597
611
624
631
638
652
667
681
696
711
726
741
756
772
787
803
811

0.4
Bhp
0.73
0.76
0.82
0.89
0.93
0.97
1.04
1.13
1.22
1.31
1.41
1.51
1.62
1.74
1.86
1.99
2.13
2.20

External Static Pressure (in. wg)


0.6
Watts
Rpm
Bhp
Watts
Rpm
680
660
0.95
885
722
709
666
0.98
916
727
768
678
1.05
982
739
832
690
1.13
1051
750
866
697
1.17
1088
756
901
703
1.21
1125
762
974
716
1.29
1204
774
1051
729
1.38
1287
786
1133
742
1.48
1376
799
1220
756
1.58
1469
811
1313
770
1.68
1568
824
1411
784
1.79
1672
837
1514
798
1.91
1781
851
1623
812
2.03
1896
864
1737
827
2.16
2017
878
1857
841
2.30
2144
892
1985
856
2.44
2277
906
2051
864
2.52
2346
913

0.8
Bhp
1.19
1.22
1.30
1.38
1.42
1.46
1.55
1.65
1.75
1.86
1.97
2.09
2.21
2.34
2.48
2.62
2.77
2.84

Watts
1106
1140
1210
1285
1324
1365
1449
1538
1632
1731
1835
1944
2060
2181
2308
2441
2580
2653

Rpm
779
784
795
805
811
816
828
839
851
863
875
888
900
913
926

1.0
Bhp
1.44
1.48
1.56
1.64
1.69
1.73
1.83
1.93
2.04
2.15
2.27
2.39
2.52
2.66
2.80

Watts
1342
1378
1453
1533
1574
1617
1707
1801
1900
2004
2114
2229
2351
2478
2610

1.8
Bhp
2.59
2.64
2.74
2.84
2.90

Watts
2420
2463
2556
2653
2704

Rpm

2.0
Bhp

Watts

50HJ008 (71/2 TONS) STANDARD MOTOR (BELT DRIVE)* (cont)


Airflow
(Cfm)
2250
2300
2400
2500
2550
2600
2700
2800
2900
3000
3100
3200
3300
3400
3500
3600
3700
3750
Bhp
Watts

Rpm
832
837
847
857
862
867
878
889
900
912
923
935
947

1.2
Bhp
1.71
1.75
1.83
1.92
1.97
2.02
2.12
2.23
2.34
2.46
2.58
2.71
2.84

Watts
1592
1630
1710
1794
1838
1884
1978
2077
2181
2290
2406
2526
2652

Rpm
882
886
896
905
910
915
926
936
947
958
969

1.4
Bhp
1.99
2.03
2.12
2.22
2.27
2.32
2.42
2.54
2.65
2.78
2.90

External Static Pressure (in. wg)


1.6
Watts
Rpm
Bhp
Watts
Rpm
1855
928
2.29
2131
973
1896
933
2.33
2174
977
1980
942
2.43
2262
986
2069
951
2.52
2355
995
2114
956
2.58
2403
999
2162
961
2.63
2453

2261
971
2.74
2556

2365
981
2.86
2664

2474

2588

2708

LEGEND
Brake Horsepower Input to Fan
Input Watts to Motor

NOTES:
1. Boldface indicates field-supplied drive is required.
2. Maximum continuous bhp is 2.90.
3. See page 187 for general fan performance notes.

*Motor drive range: 840 to 1085 rpm. All other rpms require field-supplied
drive.

50HJ
179

Performance data 50HJ (cont)


FAN PERFORMANCE VERTICAL DISCHARGE UNITS (cont)
50HJ008 (71/2 TONS) HIGH-STATIC MOTOR (BELT DRIVE)*
Airflow
(Cfm)
2250
2300
2400
2500
2550
2600
2700
2800
2900
3000
3100
3200
3300
3400
3500
3600
3700
3750

Rpm
511
519
534
550
558
565
581
597
613
630
646
663
679
696
713
729
746
755

0.2
Bhp
0.53
0.56
0.61
0.67
0.71
0.74
0.81
0.89
0.97
1.06
1.15
1.25
1.35
1.46
1.58
1.70
1.83
1.89

Watts
492
518
571
629
660
691
758
829
905
985
1071
1162
1259
1361
1469
1583
1703
1766

Rpm
591
597
611
624
631
638
652
667
681
696
711
726
741
756
772
787
803
811

0.4
Bhp
0.73
0.76
0.82
0.89
0.93
0.97
1.04
1.13
1.22
1.31
1.41
1.51
1.62
1.74
1.86
1.99
2.13
2.20

External Static Pressure (in. wg)


0.6
Watts
Rpm
Bhp
Watts
Rpm
680
660
0.95
885
722
709
666
0.98
916
727
768
678
1.05
982
739
832
690
1.13
1051
750
866
697
1.17
1088
756
901
703
1.21
1125
762
974
716
1.29
1204
774
1051
729
1.38
1287
786
1133
742
1.48
1376
799
1220
756
1.58
1469
811
1313
770
1.68
1568
824
1411
784
1.79
1672
837
1514
798
1.91
1781
851
1623
812
2.03
1896
864
1737
827
2.16
2017
878
1857
841
2.30
2144
892
1985
856
2.44
2277
906
2051
864
2.52
2346
913

0.8
Bhp
1.19
1.22
1.30
1.38
1.42
1.46
1.55
1.65
1.75
1.86
1.97
2.09
2.21
2.34
2.48
2.62
2.77
2.84

Watts
1106
1140
1210
1285
1324
1365
1449
1538
1632
1731
1835
1944
2060
2181
2308
2441
2580
2653

Rpm
779
784
795
805
811
816
828
839
851
863
875
888
900
913
926
939
953
959

1.0
Bhp
1.44
1.48
1.56
1.64
1.69
1.73
1.83
1.93
2.04
2.15
2.27
2.39
2.52
2.66
2.80
2.95
3.10
3.18

Watts
1342
1378
1453
1533
1574
1617
1707
1801
1900
2004
2114
2229
2351
2478
2610
2749
2894
2969

1.8
Bhp
2.59
2.64
2.74
2.84
2.90
2.95
3.07
3.19
3.32
3.45
3.59
3.73
3.89
4.04

Watts
2420
2463
2556
2653
2704
2755
2862
2975
3094
3217
3347
3482
3623
3771

Rpm
1015
1020
1028
1037
1041
1045
1055
1064
1073
1083
1093
1103

2.0
Bhp
2.92
2.97
3.07
3.18
3.23
3.29
3.41
3.54
3.67
3.80
3.95
4.10

Watts
2720
2766
2861
2962
3014
3068
3180
3297
3419
3547
3682
3821

50HJ008 (71/2 TONS) HIGH-STATIC MOTOR (BELT DRIVE)* (cont)


Airflow
(Cfm)
2250
2300
2400
2500
2550
2600
2700
2800
2900
3000
3100
3200
3300
3400
3500
3600
3700
3750
Bhp
Watts

Rpm
832
837
847
857
862
867
878
889
900
912
923
935
947
959
972
984
997
1004

1.2
Bhp
1.71
1.75
1.83
1.92
1.97
2.02
2.12
2.23
2.34
2.46
2.58
2.71
2.84
2.99
3.13
3.29
3.45
3.54

Watts
1592
1630
1710
1794
1838
1884
1978
2077
2181
2290
2406
2526
2652
2785
2923
3068
3218
3296

Rpm
882
886
896
905
910
915
926
936
947
958
969
980
992
1003
1015
1027
1040
1046

1.4
Bhp
1.99
2.03
2.12
2.22
2.27
2.32
2.42
2.54
2.65
2.78
2.90
3.04
3.18
3.33
3.48
3.64
3.81
3.90

External Static Pressure (in. wg)


1.6
Watts
Rpm
Bhp
Watts
Rpm
1855
928
2.29
2131
973
1896
933
2.33
2174
977
1980
942
2.43
2262
986
2069
951
2.52
2355
995
2114
956
2.58
2403
999
2162
961
2.63
2453
1004
2261
971
2.74
2556
1013
2365
981
2.86
2664
1023
2474
991
2.98
2778
1033
2588
1001
3.11
2897
1043
2708
1012
3.24
3022
1053
2834
1023
3.38
3152
1064
2966
1034
3.53
3289
1075
3103
1045
3.68
3432
1086
3246
1057
3.84
3581

3396
1068
4.01
3736

3553
1080
4.18
3897

3633

LEGEND
Brake Horsepower Input to Fan
Input Watts to Motor

50HJ

*Motor drive range: 860 to 1080 rpm. All other rpms require field-supplied
drive.

180

NOTES:
1. Boldface indicates field-supplied drive is required.
2. Maximum continuous bhp is 4.20.
3. See page 187 for general fan performance notes.

FAN PERFORMANCE VERTICAL DISCHARGE UNITS (cont)


50HJ009 (81/2 TONS) STANDARD MOTOR (BELT DRIVE)*
Airflow
(Cfm)
2500
2600
2700
2800
2900
3000
3100
3200
3300
3400
3500
3600
3700
3800
3900
4000
4100
4200
4300

Rpm
489
502
515
529
542
556
569
583
597
611
625
639
654
668
683
697
712
726
741

0.2
Bhp
0.41
0.45
0.50
0.55
0.59
0.65
0.70
0.76
0.83
0.89
0.96
1.04
1.11
1.20
1.28
1.37
1.47
1.57
1.67

Watts
386
424
465
508
555
604
656
712
770
832
898
967
1040
1116
1197
1281
1370
1462
1559

Rpm
564
576
587
599
611
623
636
648
661
674
687
700
713
726
739
753
766
780
794

0.4
Bhp
0.54
0.59
0.64
0.69
0.74
0.80
0.86
0.93
1.00
1.07
1.14
1.22
1.31
1.39
1.48
1.58
1.68
1.79
1.89

External Static Pressure (in. wg)


0.6
Watts
Rpm
Bhp
Watts
Rpm
506
629
0.67
625
688
548
640
0.72
672
697
594
650
0.77
723
707
642
661
0.83
776
718
693
672
0.89
832
728
748
684
0.95
891
738
805
695
1.02
953
749
865
707
1.09
1018
760
929
718
1.17
1086
771
996
730
1.24
1158
782
1066
742
1.32
1233
794
1140
754
1.41
1312
805
1218
767
1.50
1395
817
1299
779
1.59
1481
828
1385
792
1.69
1572
840
1474
804
1.79
1666
852
1567
817
1.89
1764
864
1665
830
2.00
1866
876
1767
843
2.12
1973
889

0.8
Bhp
0.80
0.85
0.91
0.98
1.04
1.11
1.18
1.26
1.33
1.42
1.50
1.59
1.69
1.78
1.88
1.99
2.10
2.22
2.34

Watts
745
797
852
910
970
1034
1100
1170
1244
1320
1400
1484
1571
1662
1758
1857
1960
2067
2179

Rpm
741
750
760
769
779
789
799
809
820
831
841
852
863
874
886
897
909
920
932

1.0
Bhp
0.93
0.99
1.05
1.12
1.19
1.26
1.34
1.42
1.50
1.59
1.68
1.78
1.87
1.98
2.08
2.20
2.31
2.43
2.56

Watts
866
923
982
1044
1109
1177
1249
1323
1401
1483
1567
1656
1748
1844
1943
2048
2155
2268
2384

1.8
Bhp
1.46
1.54
1.62
1.71
1.80
1.89
1.98
2.08
2.19
2.29
2.40
2.52
2.63
2.76
2.88

Watts
1362
1436
1513
1592
1675
1761
1849
1942
2038
2137
2240
2347
2457
2571
2690

Rpm
962
969
977
985
993
1001
1010
1018
1027
1036
1045
1054
1063

2.0
Bhp
1.60
1.68
1.77
1.86
1.95
2.05
2.15
2.25
2.36
2.47
2.58
2.70
2.83

Watts
1490
1568
1648
1732
1819
1909
2002
2099
2199
2303
2410
2521
2636

50HJ009 (81/2 TONS) STANDARD MOTOR (BELT DRIVE)* (cont)


Airflow
(Cfm)
2500
2600
2700
2800
2900
3000
3100
3200
3300
3400
3500
3600
3700
3800
3900
4000
4100
4200
4300
Bhp
Watts

Rpm
791
799
808
817
827
836
846
856
866
876
886
897
907
918
929
940
951
962
973

1.2
Bhp
1.06
1.12
1.19
1.26
1.34
1.42
1.50
1.58
1.67
1.76
1.86
1.96
2.06
2.17
2.28
2.40
2.52
2.65
2.78

Watts
988
1049
1113
1179
1249
1322
1398
1477
1559
1645
1734
1827
1924
2025
2130
2238
2351
2468
2589

Rpm
837
845
854
863
872
881
890
899
909
919
929
939
949
959
970
980
991
1002

1.4
Bhp
1.19
1.26
1.34
1.41
1.49
1.57
1.66
1.75
1.84
1.94
2.04
2.14
2.25
2.37
2.48
2.61
2.73
2.86

EXTERNAL STATIC PRESSURE (in. wg)


1.6
Watts
Rpm
Bhp
Watts
Rpm
1112
881
1.33
1236
922
1177
889
1.40
1306
930
1245
897
1.48
1378
938
1316
905
1.56
1454
946
1390
914
1.64
1532
954
1467
923
1.73
1613
963
1547
932
1.82
1698
972
1631
941
1.92
1786
980
1718
950
2.01
1878
989
1808
960
2.12
1972
998
1902
969
2.22
2071
1008
2000
979
2.33
2173
1017
2101
989
2.44
2279
1027
2207
999
2.56
2389
1036
2316
1009
2.68
2502
1046
2429
1019
2.81
2620

2547

2668

LEGEND
Brake Horsepower Input to Fan
Input Watts to Motor

NOTES:
1. Boldface indicates field-supplied drive is required.
2. Maximum continuous bhp is 2.90.
3. See page 187 for general fan performance notes.

*Motor drive range: 840 to 1085 rpm. All other rpms require field-supplied
drive.

50HJ
181

Performance data 50HJ (cont)


FAN PERFORMANCE VERTICAL DISCHARGE UNITS (cont)
50HJ009 (81/2 TONS) HIGH-STATIC MOTOR (BELT DRIVE)*
Airflow
(Cfm)
2500
2600
2700
2800
2900
3000
3100
3200
3300
3400
3500
3600
3700
3800
3900
4000
4100
4200
4300

Rpm
489
502
515
529
542
556
569
583
597
611
625
639
654
668
683
697
712
726
741

0.2
Bhp
0.41
0.45
0.50
0.55
0.59
0.65
0.70
0.76
0.83
0.89
0.96
1.04
1.11
1.20
1.28
1.37
1.47
1.57
1.67

Watts
386
424
465
508
555
604
656
712
770
832
898
967
1040
1116
1197
1281
1370
1462
1559

Rpm
564
576
587
599
611
623
636
648
661
674
687
700
713
726
739
753
766
780
794

0.4
Bhp
0.54
0.59
0.64
0.69
0.74
0.80
0.86
0.93
1.00
1.07
1.14
1.22
1.31
1.39
1.48
1.58
1.68
1.79
1.89

External Static Pressure (in. wg)


0.6
Watts
Rpm
Bhp
Watts
Rpm
506
629
0.67
625
688
548
640
0.72
672
697
594
650
0.77
723
707
642
661
0.83
776
718
693
672
0.89
832
728
748
684
0.95
891
738
805
695
1.02
953
749
865
707
1.09
1018
760
929
718
1.17
1086
771
996
730
1.24
1158
782
1066
742
1.32
1233
794
1140
754
1.41
1312
805
1218
767
1.50
1395
817
1299
779
1.59
1481
828
1385
792
1.69
1572
840
1474
804
1.79
1666
852
1567
817
1.89
1764
864
1665
830
2.00
1866
876
1767
843
2.12
1973
889

0.8
Bhp
0.80
0.85
0.91
0.98
1.04
1.11
1.18
1.26
1.33
1.42
1.50
1.59
1.69
1.78
1.88
1.99
2.10
2.22
2.34

Watts
745
797
852
910
970
1034
1100
1170
1244
1320
1400
1484
1571
1662
1758
1857
1960
2067
2179

Rpm
741
750
760
769
779
789
799
809
820
831
841
852
863
874
886
897
909
920
932

1.0
Bhp
0.93
0.99
1.05
1.12
1.19
1.26
1.34
1.42
1.50
1.59
1.68
1.78
1.87
1.98
2.08
2.20
2.31
2.43
2.56

Watts
866
923
982
1044
1109
1177
1249
1323
1401
1483
1567
1656
1748
1844
1943
2048
2155
2268
2384

1.8
Bhp
1.46
1.54
1.62
1.71
1.80
1.89
1.98
2.08
2.19
2.29
2.40
2.52
2.63
2.76
2.88
3.02
3.15
3.29
3.44

Watts
1362
1436
1513
1592
1675
1761
1849
1942
2038
2137
2240
2347
2457
2571
2690
2812
2939
3070
3205

Rpm
962
969
977
985
993
1001
1010
1018
1027
1036
1045
1054
1063
1073
1082
1092
1102
1112
1122

2.0
Bhp
1.60
1.68
1.77
1.86
1.95
2.05
2.15
2.25
2.36
2.47
2.58
2.70
2.83
2.95
3.09
3.22
3.36
3.51
3.66

Watts
1490
1568
1648
1732
1819
1909
2002
2099
2199
2303
2410
2521
2636
2755
2877
3004
3136
3271
3411

50HJ009 (81/2 TONS) HIGH-STATIC MOTOR (BELT DRIVE)* (cont)


Airflow
(Cfm)
2500
2600
2700
2800
2900
3000
3100
3200
3300
3400
3500
3600
3700
3800
3900
4000
4100
4200
4300
Bhp
Watts

Rpm
791
799
808
817
827
836
846
856
866
876
886
897
907
918
929
940
951
962
973

1.2
Bhp
1.06
1.12
1.19
1.26
1.34
1.42
1.50
1.58
1.67
1.76
1.86
1.96
2.06
2.17
2.28
2.40
2.52
2.65
2.78

Watts
988
1049
1113
1179
1249
1322
1398
1477
1559
1645
1734
1827
1924
2025
2130
2238
2351
2468
2589

Rpm
837
845
854
863
872
881
890
899
909
919
929
939
949
959
970
980
991
1002
1013

1.4
Bhp
1.19
1.26
1.34
1.41
1.49
1.57
1.66
1.75
1.84
1.94
2.04
2.14
2.25
2.37
2.48
2.61
2.73
2.86
3.00

External Static Pressure (in. wg)


1.6
Watts
Rpm
Bhp
Watts
Rpm
1112
881
1.33
1236
922
1177
889
1.40
1306
930
1245
897
1.48
1378
938
1316
905
1.56
1454
946
1390
914
1.64
1532
954
1467
923
1.73
1613
963
1547
932
1.82
1698
972
1631
941
1.92
1786
980
1718
950
2.01
1878
989
1808
960
2.12
1972
998
1902
969
2.22
2071
1008
2000
979
2.33
2173
1017
2101
989
2.44
2279
1027
2207
999
2.56
2389
1036
2316
1009
2.68
2502
1046
2429
1019
2.81
2620
1056
2547
1029
2.94
2743
1066
2668
1040
3.08
2869
1076
2794
1050
3.22
2999
1087

LEGEND
Brake Horsepower Input to Fan
Input Watts to Motor

50HJ

*Motor drive range: 860 to 1080 rpm. All other rpms require field-supplied
drive.

182

NOTES:
1. Boldface indicates field-supplied drive is required.
2. Maximum continuous bhp is 4.20.
3. See page 187 for general fan performance notes.

FAN PERFORMANCE VERTICAL DISCHARGE UNITS (cont)


50HJ012 (10 TONS) STANDARD MOTOR (BELT DRIVE)*
Airflow
(Cfm)
3000
3100
3200
3300
3400
3500
3600
3700
3800
3900
4000
4100
4200
4300
4400
4500
4600
4700
4800
4900
5000

Rpm
556
569
583
597
611
625
639
654
668
683
697
712
726
741
755
770
785
800
815
829
844

0.2
Bhp
0.65
0.70
0.76
0.83
0.89
0.96
1.04
1.11
1.20
1.28
1.37
1.47
1.57
1.67
1.78
1.89
2.01
2.14
2.26
2.40
2.54

Watts
604
656
712
770
832
898
967
1040
1116
1197
1281
1370
1462
1559
1660
1766
1876
1991
2111
2235
2365

Rpm
623
636
648
661
674
687
700
713
726
739
753
766
780
794
807
821
835
849
863
877
891

0.4
Bhp
0.80
0.86
0.93
1.00
1.07
1.14
1.22
1.31
1.39
1.48
1.58
1.68
1.79
1.89
2.01
2.13
2.25
2.38
2.51
2.65
2.80

External Static Pressure (in. wg)


0.6
Watts
Rpm
Bhp
Watts
Rpm
748
684
0.95
891
738
805
695
1.02
953
749
865
707
1.09
1018
760
929
718
1.17
1086
771
996
730
1.24
1158
782
1066
742
1.32
1233
794
1140
754
1.41
1312
805
1218
767
1.50
1395
817
1299
779
1.59
1481
828
1385
792
1.69
1572
840
1474
804
1.79
1666
852
1567
817
1.89
1764
864
1665
830
2.00
1866
876
1767
843
2.12
1973
889
1873
856
2.23
2084
901
1984
869
2.36
2200
914
2099
882
2.49
2320
926
2219
895
2.62
2445
939
2344
909
2.76
2575
952
2473
922
2.91
2709
965
2608
936
3.06
2849
978

0.8
Bhp
1.11
1.18
1.26
1.33
1.42
1.50
1.59
1.69
1.78
1.88
1.99
2.10
2.22
2.34
2.46
2.59
2.72
2.86
3.01
3.16
3.31

Watts
1034
1100
1170
1244
1320
1400
1484
1571
1662
1758
1857
1960
2067
2179
2295
2415
2541
2670
2805
2944
3089

Rpm
789
799
809
820
831
841
852
863
874
886
897
909
920
932
944
956
968
980
993
1005
1018

1.0
Bhp
1.26
1.34
1.42
1.50
1.59
1.68
1.78
1.87
1.98
2.08
2.20
2.31
2.43
2.56
2.69
2.82
2.96
3.10
3.25
3.41
3.57

Watts
1177
1249
1323
1401
1483
1567
1656
1748
1844
1943
2048
2155
2268
2384
2505
2630
2760
2895
3034
3178
3328

1.8
Bhp
1.89
1.98
2.08
2.19
2.29
2.40
2.52
2.63
2.76
2.88
3.02
3.15
3.29
3.44
3.59

Watts
1761
1849
1942
2038
2137
2240
2347
2457
2571
2690
2812
2939
3070
3205
3345

Rpm
1001
1010
1018
1027
1036
1045
1054
1063
1073
1082
1092
1102
1112
1122

2.0
Bhp
2.05
2.15
2.25
2.36
2.47
2.58
2.70
2.83
2.95
3.09
3.22
3.36
3.51
3.66

Watts
1909
2002
2099
2199
2303
2410
2521
2636
2755
2877
3004
3136
3271
3411

50HJ012 (10 TONS) STANDARD MOTOR (BELT DRIVE)* (cont)


Airflow
(Cfm)
3000
3100
3200
3300
3400
3500
3600
3700
3800
3900
4000
4100
4200
4300
4400
4500
4600
4700
4800
4900
5000
Bhp
Watts

Rpm
836
846
856
866
876
886
897
907
918
929
940
951
962
973
985
996
1008
1020
1032
1044

1.2
Bhp
1.42
1.50
1.58
1.67
1.76
1.86
1.96
2.06
2.17
2.28
2.40
2.52
2.65
2.78
2.91
3.05
3.20
3.34
3.50
3.66

Watts
1322
1398
1477
1559
1645
1734
1827
1924
2025
2130
2238
2351
2468
2589
2715
2845
2979
3119
3263
3413

Rpm
881
890
899
909
919
929
939
949
959
970
980
991
1002
1013
1024
1035
1046
1058

1.4
Bhp
1.57
1.66
1.75
1.84
1.94
2.04
2.14
2.25
2.37
2.48
2.61
2.73
2.86
3.00
3.14
3.28
3.43
3.58

External Static Pressure (in. wg)


1.6
Watts
Rpm
Bhp
Watts
Rpm
1467
923
1.73
1613
963
1547
932
1.82
1698
972
1631
941
1.92
1786
980
1718
950
2.01
1878
989
1808
960
2.12
1972
998
1902
969
2.22
2071
1008
2000
979
2.33
2173
1017
2101
989
2.44
2279
1027
2207
999
2.56
2389
1036
2316
1009
2.68
2502
1046
2429
1019
2.81
2620
1056
2547
1029
2.94
2743
1066
2668
1040
3.08
2869
1076
2794
1050
3.22
2999
1087
2924
1061
3.36
3134
1097
3059
1072
3.51
3274

3199
1083
3.67
3418

3343

LEGEND
Brake Horsepower Input to Fan
Input Watts to Motor

NOTES:
1. Boldface indicates field-supplied drive is required.
2. Maximum continuous bhp is 3.70.
3. See page 187 for general fan performance notes.

*Motor drive range: 860 to 1080 rpm. All other rpms require field-supplied
drive.

50HJ
183

Performance data 50HJ (cont)


FAN PERFORMANCE VERTICAL DISCHARGE UNITS (cont)
50HJ012 (10 TONS) HIGH-STATIC MOTOR (BELT DRIVE)*
External Static Pressure (in. wg)
0.6
Watts
Rpm
Bhp
Watts
Rpm
748
684
0.95
891
738
805
695
1.02
953
749
865
707
1.09
1018
760
929
718
1.17
1086
771
996
730
1.24
1158
782
1066
742
1.32
1233
794
1140
754
1.41
1312
805
1218
767
1.50
1395
817
1299
779
1.59
1481
828
1385
792
1.69
1572
840
1474
804
1.79
1666
852
1567
817
1.89
1764
864
1665
830
2.00
1866
876
1767
843
2.12
1973
889
1873
856
2.23
2084
901
1984
869
2.36
2200
914
2099
882
2.49
2320
926
2219
895
2.62
2445
939
2344
909
2.76
2575
952
2473
922
2.91
2709
965
2608
936
3.06
2849
978

0.8
Bhp
1.11
1.18
1.26
1.33
1.42
1.50
1.59
1.69
1.78
1.88
1.99
2.10
2.22
2.34
2.46
2.59
2.72
2.86
3.01
3.16
3.31

Watts
1034
1100
1170
1244
1320
1400
1484
1571
1662
1758
1857
1960
2067
2179
2295
2415
2541
2670
2805
2944
3089

Rpm
789
799
809
820
831
841
852
863
874
886
897
909
920
932
944
956
968
980
993
1005
1018

1.0
Bhp
1.26
1.34
1.42
1.50
1.59
1.68
1.78
1.87
1.98
2.08
2.20
2.31
2.43
2.56
2.69
2.82
2.96
3.10
3.25
3.41
3.57

Watts
1177
1249
1323
1401
1483
1567
1656
1748
1844
1943
2048
2155
2268
2384
2505
2630
2760
2895
3034
3178
3328

50HJ012 (10 TONS) HIGH-STATIC MOTOR (BELT DRIVE)* (cont)


External Static Pressure (in. wg)
Airflow
1.2
1.4
1.6
(Cfm)
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
3000
836
1.42
1322
881
1.57
1467
923
1.73
1613
963
3100
846
1.50
1398
890
1.66
1547
932
1.82
1698
972
3200
856
1.58
1477
899
1.75
1631
941
1.92
1786
980
3300
866
1.67
1559
909
1.84
1718
950
2.01
1878
989
3400
876
1.76
1645
919
1.94
1808
960
2.12
1972
998
3500
886
1.86
1734
929
2.04
1902
969
2.22
2071
1008
3600
897
1.96
1827
939
2.14
2000
979
2.33
2173
1017
3700
907
2.06
1924
949
2.25
2101
989
2.44
2279
1027
3800
918
2.17
2025
959
2.37
2207
999
2.56
2389
1036
3900
929
2.28
2130
970
2.48
2316
1009
2.68
2502
1046
4000
940
2.40
2238
980
2.61
2429
1019
2.81
2620
1056
4100
951
2.52
2351
991
2.73
2547
1029
2.94
2743
1066
4200
962
2.65
2468
1002
2.86
2668
1040
3.08
2869
1076
4300
973
2.78
2589
1013
3.00
2794
1050
3.22
2999
1087
4400
985
2.91
2715
1024
3.14
2924
1061
3.36
3134
1097
4500
996
3.05
2845
1035
3.28
3059
1072
3.51
3274
1108
4600
1008
3.20
2979
1046
3.43
3199
1083
3.67
3418
1118
4700
1020
3.34
3119
1058
3.58
3343
1094
3.83
3567
1129
4800
1032
3.50
3263
1069
3.74
3492
1105
3.99
3721
1140
4900
1044
3.66
3413
1081
3.91
3646
1117
4.16
3880
1151
5000
1056
3.82
3566
1093
4.08
3805
1128
4.34
4044
1162

1.8
Bhp
1.89
1.98
2.08
2.19
2.29
2.40
2.52
2.63
2.76
2.88
3.02
3.15
3.29
3.44
3.59
3.74
3.90
4.07
4.24
4.41
4.59

Watts
1761
1849
1942
2038
2137
2240
2347
2457
2571
2690
2812
2939
3070
3205
3345
3489
3638
3792
3950
4113
4282

Rpm
1001
1010
1018
1027
1036
1045
1054
1063
1073
1082
1092
1102
1112
1122
1132
1142
1152
1163
1174
1184
1195

2.0
Bhp
2.05
2.15
2.25
2.36
2.47
2.58
2.70
2.83
2.95
3.09
3.22
3.36
3.51
3.66
3.81
3.97
4.14
4.31
4.48
4.66
4.85

Watts
1909
2002
2099
2199
2303
2410
2521
2636
2755
2877
3004
3136
3271
3411
3555
3704
3857
4016
4179
4347
4520

Airflow
(Cfm)
3000
3100
3200
3300
3400
3500
3600
3700
3800
3900
4000
4100
4200
4300
4400
4500
4600
4700
4800
4900
5000

Bhp
Watts

Rpm
556
569
583
597
611
625
639
654
668
683
697
712
726
741
755
770
785
800
815
829
844

0.2
Bhp
0.65
0.70
0.76
0.83
0.89
0.96
1.04
1.11
1.20
1.28
1.37
1.47
1.57
1.67
1.78
1.89
2.01
2.14
2.26
2.40
2.54

Watts
604
656
712
770
832
898
967
1040
1116
1197
1281
1370
1462
1559
1660
1766
1876
1991
2111
2235
2365

Rpm
623
636
648
661
674
687
700
713
726
739
753
766
780
794
807
821
835
849
863
877
891

0.4
Bhp
0.80
0.86
0.93
1.00
1.07
1.14
1.22
1.31
1.39
1.48
1.58
1.68
1.79
1.89
2.01
2.13
2.25
2.38
2.51
2.65
2.80

LEGEND
Brake Horsepower Input to Fan
Input Watts to Motor

50HJ

*Motor drive range: 830 to 1130 rpm. All other rpms require field-supplied
drive.

184

NOTES:
1. Boldface indicates field-supplied drive is required.
2. Maximum continuous bhp is 5.25.
3. See page 187 for general fan performance notes.

FAN PERFORMANCE VERTICAL DISCHARGE UNITS (cont)


50HJ014 (121/2 TONS) STANDARD MOTOR (BELT DRIVE)*
External Static Pressure (in. wg)
0.6
Watts
Rpm
Bhp
Watts
Rpm
1218
767
1.50
1395
817
1299
779
1.59
1481
828
1385
792
1.69
1572
840
1474
804
1.79
1666
852
1567
817
1.89
1764
864
1665
830
2.00
1866
876
1767
843
2.12
1973
889
1873
856
2.23
2084
901
1984
869
2.36
2200
914
2099
882
2.49
2320
926
2219
895
2.62
2445
939
2344
909
2.76
2575
952
2473
922
2.91
2709
965
2608
936
3.06
2849
978
2747
949
3.21
2994
991
2892
963
3.37
3143
1004
3042
977
3.54
3298
1017
3198
990
3.71
3459
1030
3359
1004
3.89
3625
1044
3525
1018
4.07
3796
1057
3698
1032
4.26
3974
1070
3876
1046
4.46
4157
1084
4060
1060
4.66
4346
1098
4250
1074
4.87
4541
1111
4446
1088
5.09
4742

4649

0.8
Bhp
1.69
1.78
1.88
1.99
2.10
2.22
2.34
2.46
2.59
2.72
2.86
3.01
3.16
3.31
3.47
3.64
3.81
3.99
4.17
4.36
4.56
4.76
4.97
5.18

Watts
1571
1662
1758
1857
1960
2067
2179
2295
2415
2541
2670
2805
2944
3089
3238
3393
3553
3719
3890
4066
4249
4436
4630
4831

Rpm
863
874
886
897
909
920
932
944
956
968
980
993
1005
1018
1030
1043
1056
1068
1081
1094
1107
1120

1.0
Bhp
1.87
1.98
2.08
2.20
2.31
2.43
2.56
2.69
2.82
2.96
3.10
3.25
3.41
3.57
3.73
3.91
4.08
4.27
4.45
4.65
4.85
5.06

Watts
1748
1844
1943
2048
2155
2268
2384
2505
2630
2760
2895
3034
3178
3328
3483
3642
3807
3977
4153
4335
4522
4715

50HJ014 (121/2 TONS) STANDARD MOTOR (BELT DRIVE)* (cont)


External Static Pressure (in. wg)
Airflow
1.2
1.4
1.6
(Cfm)
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
3700
907
2.06
1924
949
2.25
2101
989
2.44
2279
1027
3800
918
2.17
2025
959
2.37
2207
999
2.56
2389
1036
3900
929
2.28
2130
970
2.48
2316
1009
2.68
2502
1046
4000
940
2.40
2238
980
2.61
2429
1019
2.81
2620
1056
4100
951
2.52
2351
991
2.73
2547
1029
2.94
2743
1066
4200
962
2.65
2468
1002
2.86
2668
1040
3.08
2869
1076
4300
973
2.78
2589
1013
3.00
2794
1050
3.22
2999
1087
4400
985
2.91
2715
1024
3.14
2924
1061
3.36
3134
1097
4500
996
3.05
2845
1035
3.28
3059
1072
3.51
3274
1108
4600
1008
3.20
2979
1046
3.43
3199
1083
3.67
3418
1118
4700
1020
3.34
3119
1058
3.58
3343
1094
3.83
3567
1129
4800
1032
3.50
3263
1069
3.74
3492
1105
3.99
3721
1140
4900
1044
3.66
3413
1081
3.91
3646
1117
4.16
3880
1151
5000
1056
3.82
3566
1093
4.08
3805
1128
4.34
4044
1162
5100
1068
4.00
3726
1104
4.26
3969
1139
4.52
4212
1173
5200
1080
4.17
3891
1116
4.44
4139
1151
4.70
4386
1185
5300
1093
4.35
4060
1128
4.63
4314
1163
4.90
4566
1196
5400
1105
4.54
4236
1140
4.82
4494
1174
5.10
4751

5500
1118
4.74
4417
1152
5.02
4679

5600
1130
4.94
4603

5700

5800

5900

6000

6100

6200

6300

1.8
Bhp
2.63
2.76
2.88
3.02
3.15
3.29
3.44
3.59
3.74
3.90
4.07
4.24
4.41
4.59
4.78
4.97
5.17

Watts
2457
2571
2690
2812
2939
3070
3205
3345
3489
3638
3792
3950
4113
4282
4456
4634
4819

Rpm
1063
1073
1082
1092
1102
1112
1122
1132
1142
1152
1163
1174
1184
1195
1206

2.0
Bhp
2.83
2.95
3.09
3.22
3.36
3.51
3.66
3.81
3.97
4.14
4.31
4.48
4.66
4.85
5.04

Watts
2636
2755
2877
3004
3136
3271
3411
3555
3704
3857
4016
4179
4347
4520
4699

Airflow
(Cfm)
3700
3800
3900
4000
4100
4200
4300
4400
4500
4600
4700
4800
4900
5000
5100
5200
5300
5400
5500
5600
5700
5800
5900
6000
6100
6200
6300

Watts
1040
1116
1197
1281
1370
1462
1559
1660
1766
1876
1991
2111
2235
2365
2499
2640
2784
2936
3092
3253
3421
3594
3773
3958
4149
4347
4550

Rpm
713
726
739
753
766
780
794
807
821
835
849
863
877
891
906
920
934
949
963
977
992
1006
1021
1036
1050
1065

0.4
Bhp
1.31
1.39
1.48
1.58
1.68
1.79
1.89
2.01
2.13
2.25
2.38
2.51
2.65
2.80
2.95
3.10
3.26
3.43
3.60
3.78
3.97
4.16
4.35
4.56
4.77
4.99

LEGEND
Brake Horsepower Input to Fan
Input Watts to Motor

NOTES:
1. Boldface indicates field-supplied drive is required.
2. Maximum continuous bhp is 5.25.
3. See page 187 for general fan performance notes.

50HJ

Bhp
Watts

Rpm
654
668
683
697
712
726
741
755
770
785
800
815
829
844
859
874
889
904
920
935
950
965
980
995
1011
1026
1041

0.2
Bhp
1.11
1.20
1.28
1.37
1.47
1.57
1.67
1.78
1.89
2.01
2.14
2.26
2.40
2.54
2.68
2.83
2.99
3.15
3.32
3.49
3.67
3.85
4.05
4.24
4.45
4.66
4.88

*Motor drive range: 830 to 1130 rpm. All other rpms require field-supplied
drive.

185

Performance data 50HJ (cont)


FAN PERFORMANCE VERTICAL DISCHARGE UNITS (cont)
50HJ015 (12 TONS) WITH STANDARD MOTOR*
Airflow
(Cfm)
3750
4000
4250
4500
4750
5000
5250
5500
5750
6000
6250

Rpm
542
564
586
610
634
659
684
710
736
762
788

0.2
Watts
687
792
903
1021
1147
1281
1423
1572
1732
1900
2080

Bhp
0.72
0.83
0.96
1.09
1.24
1.40
1.58
1.78
1.98
2.21
2.45

Rpm
649
666
684
702
721
741
762
783
805
828
851

0.4
Watts
841
956
1078
1207
1343
1486
1637
1796
1965
2143
2332

Available External Static Pressure (in. wg)


0.6
Bhp
Rpm
Watts
Bhp
Rpm
0.96
737
1045
1.19
813
1.08
754
1170
1.33
829
1.21
771
1302
1.47
846
1.35
789
1440
1.63
863
1.51
806
1584
1.80
880
1.68
823
1735
1.98
897
1.86
841
1894
2.17
914
2.06
859
2060
2.38
932
2.28
878
2235
2.60
949
2.51
898
2419
2.84
967
2.76
918
2612
3.09

0.8
Watts
1229
1364
1506
1653
1807
1968
2135
2311
2496
2689

Bhp
1.43
1.58
1.73
1.90
2.08
2.28
2.48
2.70
2.94
3.18

Rpm
882
897
913
929
946
963
980
997
1014

1.0
Watts
1419
1565
1716
1873
2037
2207
2385
2571
2765

Bhp
1.68
1.83
2.00
2.18
2.37
2.57
2.79
3.03
3.27

1.4
Watts
1823
1989
2161
2339
2524
2717

Available External Static Pressure (in. wg)


1.6
Bhp
Rpm
Watts
Bhp
Rpm
2.20
1069
2051
2.47
1127
2.36
1079
2227
2.64
1135
2.54
1090
2408
2.83
1144
2.74
1102
2596
3.03
1155
2.95
1116
2790
3.24

3.17

1.8
Watts
2301
2486
2676
2843

Bhp
2.75
2.93
3.12
3.33

Rpm
1184
1190

2.0
Watts
2563
2756

Bhp
3.05
3.23

50HJ015 (12 TONS) WITH STANDARD MOTOR* (cont)


Airflow
(Cfm)
3750
4000
4250
4500
4750
5000
5250
5500
5750
6000
6250

Rpm
947
960
975
990
1006
1022
1039
1056

1.2
Watts
1617
1773
1934
2102
2276
2457
2646
2843

Bhp
1.93
2.09
2.27
2.45
2.66
2.87
3.10
3.35

Rpm
1009
1020
1033
1047
1062
1078

LEGEND
Bhp
Brake Horsepower
Watts Input Watts to Motor
*Standard low-medium static drive range is 895 to 1147 rpm. Alternate high-static
drive range is 1040 to 1315 (for 208/230 and 460-v units). The alternate highstatic drive range is not available for 575-v units. Other rpms require a fieldsupplied drive.

NOTES:
1. Boldface indicates field-supplied drive required.
2. Maximum continuous bhp for the standard motor is 3.13 (for 208/230 and
460-v units) or 3.38 (for 575-v units). The maximum continuous watts is
2700 (for 208/230 and 460-v units) or 3065 (for 575-v units). Do not adjust
motor rpm such that motor maximum bhp and/or watts is exceeded at the
maximum operating cfm.
3. Fan performance is identical for horizontal discharge applications using
Carrier horizontal adapter curb.
4. See page 187 for general fan performance notes.

50HJ015 (12 TONS) WITH OPTIONAL MOTOR*


Airflow
(Cfm)
3750
4000
4250
4500
4750
5000
5250
5500
5750
6000
6250

Rpm
542
564
586
610
634
659
684
710
736
762
788

0.2
Watts
687
792
903
1021
1147
1281
1423
1572
1732
1900
2080

Bhp
0.72
0.83
0.96
1.09
1.24
1.40
1.58
1.78
1.98
2.21
2.45

Rpm
649
666
684
702
721
741
762
783
805
828
851

0.4
Watts
841
956
1078
1207
1343
1486
1637
1796
1965
2143
2332

Available External Static Pressure (in. wg)


0.6
Bhp
Rpm
Watts
Bhp
Rpm
0.96
737
1045
1.19
813
1.08
754
1170
1.33
829
1.21
771
1302
1.47
846
1.35
789
1440
1.63
863
1.51
806
1584
1.80
880
1.68
823
1735
1.98
897
1.86
841
1894
2.17
914
2.06
859
2060
2.38
932
2.28
878
2235
2.60
949
2.51
898
2419
2.84
967
2.76
918
2612
3.09
985

0.8
Watts
1229
1364
1506
1653
1807
1968
2135
2311
2496
2689
2892

Bhp
1.43
1.58
1.73
1.90
2.08
2.28
2.48
2.70
2.94
3.18
3.45

Rpm
882
897
913
929
946
963
980
997
1014
1031
1048

Bhp
2.75
2.93
3.12
3.33
3.55
3.79
4.04

Rpm
1184
1190
1197
1207
1218
1231

1.0
Watts
1419
1565
1716
1873
2037
2207
2385
2571
2765
2968
3181

Bhp
1.68
1.83
2.00
2.18
2.37
2.57
2.79
3.03
3.27
3.53
3.81

50HJ015 (12 TONS) WITH OPTIONAL MOTOR* (cont)

50HJ

Airflow
(Cfm)
3750
4000
4250
4500
4750
5000
5250
5500
5750
6000
6250

Rpm
947
960
975
990
1006
1022
1039
1056
1073
1090
1107

1.2
Watts
1617
1773
1934
2102
2276
2457
2646
2843

3048
3261
3483

Bhp
1.93
2.09
2.27
2.45
2.66
2.87
3.10
3.35
3.60
3.88
4.16

Rpm
1009
1020
1033
1047
1062
1078
1094
1111
1128
1145

1.4
Watts
1823
1989
2161
2339
2524
2717

2916
3124
3339
3562

Available External Static Pressure (in. wg)


1.6
Bhp
Rpm
Watts
Bhp
Rpm
2.20
1069
2051
2.47
1127
2.36
1079
2227
2.64
1135
2.54
1090
2408
2.83
1144
2.74
1102
2596
3.03
1155
2.95
1116
2790
3.24
1168
3.17
1131
2990
3.48
1182
3.41
1146
3.73
1196
3198
3.67
1162
3412
3.99

3.94

4.22

LEGEND
Bhp
Brake Horsepower
Watts Input Watts to Motor
*Standard low-medium static drive range is 895 to 1147 rpm. Alternate high-static
drive range is 1040 to 1315. Other rpms require a field-supplied drive.

186

1.8
Watts
2301
2486
2676

2872
3073
3280
3493

2.0
Watts
2563
2756

2954
3158
3366
3579

Bhp
3.05
3.23
3.42
3.63
3.86
4.10

NOTES:
1. Boldface indicates field-supplied drive required.
2. Maximum continuous bhp for the standard motor is 4.26. The maximum continuous watts is 3610. Do not adjust motor rpm such that motor maximum
bhp and/or watts is exceeded at the maximum operating cfm.
3. Fan performance is identical for horizontal discharge applications using
Carrier horizontal adapter curb.
4. See page 187 for general fan performance notes.

FAN PERFORMANCE VERTICAL DISCHARGE UNITS (cont)


50HJ017* (15 TONS)
Airflow
(Cfm)
4500
4800
5100
5700
6000
6300
6600
6900
7200
7500

Rpm
753
747
741
735
759
790
821
852
883
914

0.2
Watts
1307
1384
1465
1659
1854
2088
2340
2611
2903
3215

Bhp
1.53
1.62
1.76
2.22
2.48
2.77
3.07
3.40
3.75
4.13

Available External Static Pressure (in. wg)


0.6
0.8
Rpm Watts
Bhp
Rpm Watts
Bhp
784
1397
1.64
859
1635
1.92
806
1563
1.83
878
1808
2.12
828
1745
2.05
898
1996
2.34
876
2156
2.53
942
2423
2.84
901
2388
2.80
965
2663
3.12
926
2638
3.09
988
2920
3.43
952
2906
3.41
1013
3196
3.75
979
3194
3.75
1038
3492
4.10
1006
3501
4.11
1063
3807
4.47
1033
3830
4.49
1089
4143
4.86

Rpm
928
946
964
1004
1026
1048
1070
1094
1118
1142

1.0
Watts
1880
2060
2255
2696
2943
3208
3491
3794
4117
4461

Bhp
2.20
2.42
2.65
3.16
3.45
3.76
4.10
4.45
4.83
5.23

Rpm
993
1009
1026
1064
1083
1104
1125
1147
1170
1193

1.2
Watts
2133
2319
2521
2975
3228
3501
3791
4101
4431
4781

Bhp
2.50
2.72
2.96
3.49
3.79
4.11
4.45
4.81
5.20
5.61

Bhp
3.12
3.35
3.60
4.17
4.48
4.81
5.17
5.55
5.95

Available External Static Pressure (in. wg)


1.8
2.0
Rpm Watts
Bhp
Rpm Watts
Bhp
1170
2938
3.45
1224
3220
3.78
1183
3139
3.68
1236
3427
4.02
1196
3359
3.94
1248
3650
4.28
1226
3848
4.51
1277
4151
4.87
1243
4119
4.83
1292
4427
5.19
1260
4410
5.17
1309
4724
5.54
1278
4720
5.54
1326
5039
5.91
1297
5050
5.92

Rpm
1276
1287
1299
1325
1340
1356

2.2
Watts
3509
3721
3949
4458
4741
5043

Bhp
4.12
4.36
4.63
5.23
5.56
5.91

Rpm
1326
1336
1347
1373
1387

2.4
Watts
3805
4020
4253
4772
5060

Bhp
4.46
4.72
4.99
5.60
5.93

Rpm
753
747
752
805
832
860
888
917
946
975

0.4
Watts
1307
1384
1500
1895
2118
2360
2621
2900
3200
3521

Bhp
2.81
3.03
3.28
3.82
4.13
4.46
4.80
5.18
5.57
5.99

Rpm
1114
1127
1142
1174
1192
1210
1229
1249
1270

1.6
Watts
2662
2859
3073
3551
3817
4102
4405
4728
5072

Bhp
4.82
5.07
5.35
5.97

Available External Static Pressure (in. wg)


2.8
3.0
Rpm Watts
Bhp
Rpm Watts
Bhp
1421
4414
5.18
1467
4728
5.55
1430
4638
5.44
1475
4955
5.81
1440
4879
5.72

Bhp
1.53
1.62
1.72
1.95
2.18
2.45
2.74
3.06
3.40
3.77

50HJ017* (15 TONS) (cont)


Airflow
(Cfm)
4500
4800
5100
5700
6000
6300
6600
6900
7200
7500

Rpm
1055
1070
1086
1120
1139
1158
1178
1199
1221
1243

1.4
Watts
2394
2585
2794
3260
3520
3799
4095
4412
4749
5107

50HJ017* (15 TONS) (cont)


Airflow
(Cfm)
4500
4800
5100
5700
6000
6300
6600
6900
7200
7500

Rpm
1375
1384
1395
1418

2.6
Watts
4107
4326
4563
5091

LEGEND
Bhp
Brake Horsepower
Watts Input Watts to Motor
*Standard low-medium static drive range is 873 to 1021 rpm. Alternate high-static
drive range is 1025 to 1200. Other rpms require a field-supplied drive.

Rpm
1511

3.2
Watts
5047

Bhp
5.92

NOTES:
1. Maximum continuous bhp for the standard motor is 6.13. The maximum continuous watts is 5180. Do not adjust motor rpm such that motor maximum
bhp and/or watts is exceeded at the maximum operating cfm.
2. Fan performance is identical for horizontal discharge applications using
Carrier horizontal adapter curb.
3. See below for general fan performance notes.

GENERAL FAN PERFORMANCE NOTES


nuisance tripping or premature motor failure. Unit warranty will not
be affected. See Evaporator-Fan Motor Performance tables on
pages 206-209 for additional information.
3. Use of a field-supplied motor may affect wire sizing. Contact your
Carrier representative for details.
4. Interpolation is permissible. Do not extrapolate.

187

50HJ

NOTES:
1. Values include losses for filters, unit casing, and wet coils. See
pages 211-214 for accessory/factory-installed option static pressure information.
2. Extensive motor and electrical testing on these units ensures that
the full range of the motor can be utilized with confidence. Using
your fan motors up to the wattage ratings shown will not result in

Performance data 50HJ (cont)


FAN PERFORMANCE VERTICAL DISCHARGE UNITS (cont)
50HJ020* (18 TONS)
Airflow
(Cfm)

3500
4000
4500
5000
5500
6000
6500
7000
7500
8000
8500

Rpm

0.2
Watts

Bhp

423
454
487
522
559
598
637
677
718
759
801

522
675
859
1077
1330
1621
1953
2327
2745
3209
3722

0.60
0.78
0.99
1.24
1.53
1.86
2.25
2.68
3.16
3.69
4.28

Rpm

0.4
Watts

Available External Static Pressure (in. wg)


0.6
Bhp
Rpm
Watts
Bhp
Rpm

0.8
Watts

Bhp

Rpm

1.0
Watts

Bhp

521
545
572
601
632
664
698
734
770
808
846

715
884
1082
1311
1573
1873
2212
2593
3018
3489
4007

0.82
1.02
1.24
1.51
1.81
2.15
2.54
2.98
3.47
4.01
4.61

679
697
717
739
763
789
817
846
876
907
940

1093
1299
1529
1789
2080
2405
2766
3167
3609
4095
4628

1.26
1.49
1.76
2.06
2.39
2.77
3.18
3.64
4.15
4.71
5.32

747
762
780
800
822
846
871
898
926
956
986

1278
1502
1750
2026
2332
2671
3046
3459
3913
4410
4952

1.47
1.73
2.01
2.33
2.68
3.07
3.50
3.98
4.50
5.07
5.69

Available External Static Pressure (in. wg)


1.6
Bhp
Rpm
Watts
Bhp
Rpm

1.8
Watts

Bhp

Rpm

2.0
Watts

Bhp

1.89
2.19
2.51
2.87
3.26
3.68
4.15
4.65
5.20
5.80
6.45

1999
2296
2613
2956
3326
3726
4159
4627
5134
5680
6268

2.30
2.64
3.01
3.40
3.83
4.29
4.78
5.32
5.90
6.53
7.21

1024
1034
1045
1058
1073
1090
1108
1128
1150
1173
1197

2176
2490
2826
3185
3570
3986
4434
4917
5436
5995
6596

2.50
2.86
3.25
3.66
4.11
4.58
5.10
5.65
6.25
6.90
7.59

605
625
648
673
700
729
759
791
824
858
893

906
1093
1307
1550
1826
2137
2486
2876
3309
3787
4311

1.04
1.26
1.50
1.78
2.10
2.46
2.86
3.31
3.81
4.36
4.96

50HJ020* (18 TONS) (cont)


Airflow
(Cfm)

3500
4000
4500
5000
5500
6000
6500
7000
7500
8000
8500

Rpm

1.2
Watts

Bhp

Rpm

1.4
Watts

810
823
839
857
877
899
923
948
975
1002
1031

1461
1703
1969
2261
2583
2937
3327
3753
4219
4727
5280

1.68
1.96
2.26
2.60
2.97
3.38
3.83
4.32
4.85
5.44
6.07

868
880
894
911
930
950
972
996
1021
1047
1075

1642
1902
2185
2494
2832
3202
3606
4045
4525
5045
5609

923
934
947
962
979
999
1020
1042
1066
1091
1117

LEGEND
Bhp Brake Horsepower Input to Fan
Watts Input Watts to Motor

50HJ

*Motor drive ranges:


Low Range: Not Used
Mid-Low Range: 647-886 (208/230 and 460-v), 810-1072 (575-v)
Mid-High Range: 897-1139 (208/230 and 460-v), 873-1108 (575-v)
High Range: 1078-1274
All other rpms require field-supplied drive.

188

1821
2100
2400
2726
3080
3465
3883
4337
4829
5362
5938

2.09
2.42
2.76
3.14
3.54
3.98
4.47
4.99
5.55
6.17
6.83

975
985
997
1011
1027
1045
1065
1086
1109
1133
1158

NOTES:
1. Maximum continuous bhp is:
Low Range: Not Used
Mid-Low Range: 4.25 (208/230 and 460-v), 3.45 (575-v)
Mid-High Range: 5.75
High Range: 8.63
2. See page 187 for general fan performance notes.

FAN PERFORMANCE VERTICAL DISCHARGE UNITS (cont)


50HJ024* (20 TONS)
Airflow
(Cfm)

5,000
5,500
6,000
6,500
7,000
7,500
8,000
8,500
9,000
9,500
10,000

Rpm

0.2
Watts

Bhp

533
571
610
650
691
732
775
817
860
903
947

1106
1366
1666
2007
2391
2820
3297
3823
4400
5031
5715

1.27
1.57
1.92
2.31
2.75
3.24
3.79
4.40
5.06
5.79
6.57

Rpm

0.4
Watts

Available External Static Pressure (in. wg)


0.6
Bhp
Rpm
Watts
Bhp
Rpm

0.8
Watts

Bhp

Rpm

1.0
Watts

Bhp

611
643
676
712
748
786
824
863
904
944
985

1342
1613
1922
2271
2663
3100
3585
4118
4702
5339
6030

1.54
1.86
2.21
2.61
3.06
3.57
4.12
4.74
5.41
6.14
6.93

748
773
800
829
859
891
924
958
993
1028
1065

1822
2121
2456
2829
3242
3698
4200
4749
5347
5998
6703

2.10
2.44
2.82
3.25
3.73
4.25
4.83
5.46
6.15
6.90
7.71

808
832
857
883
911
941
972
1003
1036
1070
1105

2059
2374
2724
3110
3536
4004
4516
5075
5683
6343
7055

2.37
2.73
3.13
3.58
4.07
4.61
5.19
5.84
6.54
7.29
8.11

Available External Static Pressure (in. wg)


1.6
Bhp
Rpm
Watts
Bhp
Rpm

1.8
Watts

Bhp

Rpm

2.0
Watts

Bhp

2.91
3.31
3.74
4.22
4.74
5.31
5.93
6.60
7.32
8.10
8.94

2990
3369
3779
4224
4706
5227
5790
6396
7048
7749
8500

3.44
3.87
4.35
4.86
5.41
6.01
6.66
7.36
8.11
8.91
9.78

1065
1081
1099
1118
1140
1163
1187
1212
1239
1266
1295

3219
3614
4040
4499
4996
5530
6106
6725
7390
8102
8864

3.70
4.16
4.65
5.18
5.75
6.36
7.02
7.73
8.50
9.32
10.20

682
711
740
772
805
839
874
911
948
986
1025

1582
1867
2188
2548
2949
3395
3887
4428
5019
5663
6360

1.82
2.15
2.52
2.93
3.39
3.91
4.47
5.09
5.77
6.51
7.32

50HJ024* (20 TONS) (cont)


Airflow
(Cfm)

5,000
5,500
6,000
6,500
7,000
7,500
8,000
8,500
9,000
9,500
10,000

Rpm

1.2
Watts

Bhp

Rpm

1.4
Watts

865
886
910
935
961
989
1018
1048
1079
1112
1145

2294
2625
2990
3391
3830
4311
4835
5405
6022
6691
7412

2.64
3.02
3.44
3.90
4.40
4.96
5.56
6.22
6.93
7.70
8.52

918
938
960
984
1008
1035
1062
1091
1121
1152
1184

2527
2875
3254
3670
4123
4617
5153
5735
6364
7042
7773

LEGEND
Bhp Brake Horsepower Input to Fan
Watts Input Watts to Motor
*Motor drive ranges:
Low Range: 685-939 (208/230 and 460-v), 751-954 (575-v)
Mid-Low Range: 949-1206
Mid-High Range: 941-1176
High Range: 1014-1297
All other rpms require field-supplied drive.

969
988
1008
1030
1054
1079
1105
1133
1161
1191
1222

2760
3123
3518
3948
4415
4922
5472
6065
6706
7395
8135

3.17
3.59
4.05
4.54
5.08
5.66
6.29
6.98
7.71
8.51
9.36

1018
1035
1054
1075
1098
1122
1147
1173
1201
1229
1259

NOTES:
1. Maximum continuous bhp is:
Low Range: 4.25 (208/230 and 460-v), 5.75 (575-v)
Mid-Low Range: 5.75
Mid-High Range: 8.63
High Range: 11.50
2. See page 187 for general fan performance notes.

50HJ
189

Performance data 50HJ (cont)


FAN PERFORMANCE VERTICAL DISCHARGE UNITS (cont)
50HJ028* (25 TONS)
Airflow
(Cfm)

6,500
7,000
7,500
8,000
8,500
9,000
9,500
10,000
10,500
11,000
11,500
12,000
12,500

Rpm

0.2
Watts

Bhp

Rpm

0.4
Watts

734
728
746
786
827
870
913
957
1002
1047
1092
1137
1182

2384
2506
2738
3148
3611
4125
4691
5312
5988
6719
7507
8356
9264

2.74
2.88
3.15
3.62
4.15
4.74
5.40
6.11
6.89
7.73
8.63
9.61
10.65

752
792
831
869
905
940
975
1010
1047
1086
1126
1168
1210

2482
2911
3375
3868
4384
4921
5480
6073
6715
7416
8180
9009
9903

Available External Static Pressure (in. wg)


0.6
Bhp
Rpm
Watts
Bhp
Rpm

2.85
3.35
3.88
4.45
5.04
5.66
6.30
6.98
7.72
8.53
9.41
10.36
11.39

803
844
884
925
964
1003
1042
1079
1115
1150
1185
1220
1256

2,752
3,220
3,734
4,292
4,891
5,529
6,202
6,906
7,635
8,388
9,163
9,975
10,835

3.16
3.70
4.29
4.94
5.63
6.36
7.13
7.94
8.78
9.65
10.54
11.47
12.46

848
887
927
968
1008
1049
1089
1128
1167
1205
1242
1278
1314

0.8
Watts

Bhp

Rpm

1.0
Watts

Bhp

2,998
3,484
4,023
4,612
5,251
5,939
6,674
7,453
8,275
9,133
10,025
10,945
11,891

3.45
4.01
4.63
5.30
6.04
6.83
7.68
8.57
9.52
10.50
11.53
12.59
13.68

891
928
966
1006
1046
1086
1127
1167
1207
1247
1286
1325

3,250
3,742
4,293
4,901
5,564
6,281
7,053
7,876
8,751
9,674
10,642
11,654

3.74
4.30
4.94
5.64
6.40
7.22
8.11
9.06
10.06
11.13
12.24
13.40

1.8
Watts

Bhp

Rpm

2.0
Watts

Bhp

4,540
4,960
5,474
6,076
6,756
7,512
8,340
9,237
10,203
11,237

5.22
5.70
6.30
6.99
7.77
8.64
9.59
10.62
11.73
12.92

1119
1134
1155
1181
1212
1246
1282
1319
1358
1397

4,961
5,344
5,830
6,412
7,081
7,832
8,660
9,563
10,537
11,584

5.71
6.15
6.71
7.37
8.14
9.01
9.96
11.00
12.12
13.32

50HJ028* (25 TONS) (cont)


Airflow
(Cfm)

6,500
7,000
7,500
8,000
8,500
9,000
9,500
10,000
10,500
11,000
11,500
12,000
12,500

Rpm

1.2
Watts

Bhp

Rpm

1.4
Watts

934
967
1003
1041
1081
1121
1161
1202
1242
1282
1322

3,521
4,010
4,565
5,181
5,859
6,595
7,390
8,244
9,154
10,118
11,136

4.05
4.61
5.25
5.96
6.74
7.59
8.50
9.48
10.53
11.64
12.81

978
1007
1040
1076
1114
1153
1193
1233
1273
1314
1354

3,822
4,297
4,847
5,465
6,150
6,899
7,710
8,584
9,519
10,514
11,568

LEGEND
Bhp Brake Horsepower Input to Fan
Watts Input Watts to Motor

50HJ

*Motor drive ranges:


Low Range: 687-873
Mid-Low Range: 805-1007
Mid-High Range: 941-1176
High Range: 1014-1297
All other rpms require field-supplied drive.

190

Available External Static Pressure (in. wg)


1.6
Bhp
Rpm
Watts
Bhp
Rpm

4.40
4.94
5.57
6.29
7.07
7.93
8.87
9.87
10.95
12.09
13.30

1023
1048
1078
1111
1147
1184
1223
1263
1303
1343
1384

4,160
4,612
5,148
5,762
6,448
7,202
8,025
8,913
9,866
10,884
11,964

4.78
5.30
5.92
6.63
7.42
8.28
9.23
10.25
11.35
12.52
13.76

1071
1090
1116
1146
1179
1215
1253
1291
1331
1371

NOTES:
1. Maximum continuous bhp is:
Low Range: 5.75
Mid-Low Range: 5.75
Mid-High Range: 8.63
High Range: 11.50
2. See page 187 for general fan performance notes.

FAN PERFORMANCE HORIZONTAL DISCHARGE UNITS


50HJ004 (3 TONS) STANDARD MOTOR (BELT DRIVE)*
Airflow
(Cfm)
900
1000
1100
1200
1300
1400
1500

Rpm
554
583
612
643
674
706
738

0.2
Bhp
0.14
0.16
0.20
0.23
0.28
0.33
0.38

Watts
134
163
195
233
276
324
379

Rpm
681
707
735
762
791
820
849

0.4
Bhp
0.22
0.26
0.30
0.35
0.40
0.45
0.52

External Static Pressure (in. wg)


0.6
Watts
Rpm
Bhp
Watts
Rpm
222
783
0.32
316
870
257
808
0.36
358
894
298
834
0.41
406
919
344
860
0.46
459
944
395
887
0.52
517
970
451
914
0.59
582
997
515
942
0.66
653
1024

0.8
Bhp
0.42
0.47
0.52
0.58
0.65
0.72
0.80

Watts
416
465
519
579
645
717
796

Rpm
947
971
995
1020
1045
1071
1097

1.0
Bhp
0.53
0.58
0.64
0.71
0.78
0.86
0.95

Watts
523
578
638
705
777
857
942

1.8
Bhp
1.01
1.09
1.17

Watts
1004
1081
1165

Rpm
1254

2.0
Bhp
1.14

Watts
1136

50HJ004 (3 TONS) STANDARD MOTOR (BELT DRIVE)* (cont)


Airflow
(Cfm)
900
1000
1100
1200
1300
1400
1500
Bhp
Watts

Rpm
1017
1041
1065
1089
1114
1139
1164

1.2
Bhp
0.64
0.70
0.77
0.84
0.92
1.01
1.10

Watts
635
696
763
835
915
1000
1093

Rpm
1082
1105
1129
1153
1177
1202

1.4
Bhp
0.76
0.82
0.90
0.98
1.06
1.15

External Static Pressure (in. wg)


1.6
Watts
Rpm
Bhp
Watts
Rpm
753
1143
0.88
876
1200
820
1166
0.95
948
1223
892
1189
1.03
1026
1245
971
1212
1.12
1111

1056

1149

LEGEND
Brake Horsepower Input to Fan
Input Watts to Motor

NOTES:
1. Boldface indicates field-supplied drive is required.
2. Maximum continuous bhp is 1.20.
3. See page 187 for general fan performance notes.

*Motor drive range: 680 to 1044 rpm. All other rpms require field-supplied
drive.

50HJ004 (3 TONS) HIGH-STATIC MOTOR (BELT DRIVE)*


External Static Pressure (in. wg)
0.6
Watts
Rpm
Bhp
Watts
Rpm
222
783
0.32
316
870
257
808
0.36
358
894
298
834
0.41
406
919
344
860
0.46
459
944
395
887
0.52
517
970
451
914
0.59
582
997
515
942
0.66
653
1024

0.8
Bhp
0.42
0.47
0.52
0.58
0.65
0.72
0.80

Watts
416
465
519
579
645
717
796

Rpm
947
971
995
1020
1045
1071
1097

1.0
Bhp
0.53
0.58
0.64
0.71
0.78
0.86
0.95

Watts
523
578
638
705
777
857
942

50HJ004 (3 TONS) HIGH-STATIC MOTOR (BELT DRIVE)* (cont)


External Static Pressure (in. wg)
Airflow
1.2
1.4
1.6
(Cfm)
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
900
1017
0.64
635
1082
0.76
753
1143
0.88
876
1200
1000
1041
0.70
696
1105
0.82
820
1166
0.95
948
1223
1100
1065
0.77
763
1129
0.90
892
1189
1.03
1026
1245
1200
1089
0.84
835
1153
0.98
971
1212
1.12
1111
1269
1300
1114
0.92
915
1177
1.06
1056
1236
1.21
1202
1292
1400
1139
1.01
1000
1202
1.15
1149
1261
1.31
1301
1316
1500
1164
1.10
1093
1227
1.25
1248
1285
1.41
1407
1341

1.8
Bhp
1.01
1.09
1.17
1.26
1.36
1.47
1.58

Watts
1004
1081
1165
1256
1353
1457
1570

Rpm
1254
1276
1299
1322
1346
1369
1394

2.0
Bhp
1.14
1.23
1.32
1.41
1.52
1.63
1.75

Watts
1136
1219
1308
1404
1508
1618
1736

Airflow
(Cfm)
900
1000
1100
1200
1300
1400
1500

Watts
134
163
195
233
276
324
379

Rpm
681
707
735
762
791
820
849

0.4
Bhp
0.22
0.26
0.30
0.35
0.40
0.45
0.52

LEGEND
Brake Horsepower Input to Fan
Input Watts to Motor

NOTES:
1. Boldface indicates field-supplied drive is required.
2. Maximum continuous bhp is 2.40.
3. See page 187 for general fan performance notes.

50HJ

Bhp
Watts

Rpm
554
583
612
643
674
706
738

0.2
Bhp
0.14
0.16
0.20
0.23
0.28
0.33
0.38

*Motor drive range: 1075 to 1455 rpm. All other rpms require field-supplied
drive.

191

Performance data 50HJ (cont)


FAN PERFORMANCE HORIZONTAL DISCHARGE UNITS (cont)
50HJ005 (4 TONS) STANDARD MOTOR (BELT DRIVE)*
Airflow
(Cfm)
1200
1300
1400
1500
1600
1700
1800
1900
2000

Rpm
643
674
706
738
771
804
837
871
906

0.2
Bhp
0.23
0.28
0.33
0.38
0.44
0.51
0.59
0.67
0.76

Watts
233
276
324
379
440
507
582
665
756

Rpm
762
791
820
849
879
910
941
972
1004

0.4
Bhp
0.35
0.40
0.45
0.52
0.59
0.66
0.75
0.84
0.94

External Static Pressure (in. wg)


0.6
Watts
Rpm
Bhp
Watts
Rpm
344
860
0.46
459
944
395
887
0.52
517
970
451
914
0.59
582
997
515
942
0.66
653
1024
584
971
0.74
731
1051
661
1000
0.82
816
1079
745
1029
0.91
909
1107
837
1059
1.02
1010
1136
938
1089
1.12
1119

0.8
Bhp
0.58
0.65
0.72
0.80
0.89
0.98
1.08
1.19

Watts
579
645
717
796
881
974
1075
1184

Rpm
1020
1045
1071
1097
1124
1151

1.0
Bhp
0.71
0.78
0.86
0.95
1.04
1.14

Watts
705
777
857
942
1035
1136

External Static Pressure (in. wg)


1.6
Watts
Rpm
Bhp
Watts
Rpm
971
1212
1.12
1111

1056

1149

1.8
Bhp

Watts

Rpm

2.0
Bhp

Watts

50HJ005 (4 TONS) STANDARD MOTOR (BELT DRIVE)*


Airflow
(Cfm)
1200
1300
1400
1500
1600
1700
1800
1900
2000
Bhp
Watts

Rpm
1089
1114
1139
1164
1190

1.2
Bhp
0.84
0.92
1.01
1.10
1.20

Watts
835
915
1000
1093
1193

Rpm
1153
1177
1202

1.4
Bhp
0.98
1.06
1.15

LEGEND
Brake Horsepower Input to Fan
Input Watts to Motor

NOTES:
1. Boldface indicates field-supplied drive is required.
2. Maximum continuous bhp is 1.20.
3. See page 187 for general fan performance notes.

*Motor drive range: 770 to 1185 rpm. All other rpms require field-supplied
drive.

50HJ005 (4 TONS) HIGH-STATIC MOTOR (BELT DRIVE)*


External Static Pressure (in. wg)
0.6
Watts
Rpm
Bhp
Watts
Rpm
344
860
0.46
459
944
395
887
0.52
517
970
451
914
0.59
582
997
515
942
0.66
653
1024
584
971
0.74
731
1051
661
1000
0.82
816
1079
745
1029
0.91
909
1107
837
1059
1.02
1010
1136
938
1089
1.12
1119
1165

0.8
Bhp
0.58
0.65
0.72
0.80
0.89
0.98
1.08
1.19
1.31

Watts
579
645
717
796
881
974
1075
1184
1301

Rpm
1020
1045
1071
1097
1124
1151
1178
1206
1234

1.0
Bhp
0.71
0.78
0.86
0.95
1.04
1.14
1.25
1.37
1.49

Watts
705
777
857
942
1035
1136
1244
1361
1486

50HJ005 (4 TONS) HIGH-STATIC MOTOR (BELT DRIVE)* (cont)


External Static Pressure (in. wg)
Airflow
1.2
1.4
1.6
(Cfm)
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
1200
1089
0.84
835
1153
0.98
971
1212
1.12
1111
1269
1300
1114
0.92
915
1177
1.06
1056
1236
1.21
1202
1292
1400
1139
1.01
1000
1202
1.15
1149
1261
1.31
1301
1316
1500
1164
1.10
1093
1227
1.25
1248
1285
1.41
1407
1341
1600
1190
1.20
1193
1252
1.36
1355
1311
1.53
1520
1366
1700
1217
1.31
1301
1278
1.48
1470
1336
1.65
1642
1391
1800
1244
1.42
1417
1305
1.60
1593
1362
1.78
1772
1416
1900
1271
1.55
1541
1331
1.73
1724
1388
1.92
1911
1442
2000
1298
1.68
1674
1358
1.87
1865
1415
2.07
2059
1468

1.8
Bhp
1.26
1.36
1.47
1.58
1.70
1.83
1.97
2.11
2.27

Watts
1256
1353
1457
1570
1690
1818
1955
2101
2256

Rpm
1322
1346
1369
1394
1418
1443
1468
1494

2.0
Bhp
1.41
1.52
1.63
1.75
1.87
2.01
2.15
2.31

Watts
1404
1508
1618
1736
1863
1998
2141
2294

Airflow
(Cfm)

50HJ

1200
1300
1400
1500
1600
1700
1800
1900
2000

Bhp
Watts

Rpm
643
674
706
738
771
804
837
871
906

0.2
Bhp
0.23
0.28
0.33
0.38
0.44
0.51
0.59
0.67
0.76

Watts
233
276
324
379
440
507
582
665
756

Rpm
762
791
820
849
879
910
941
972
1004

0.4
Bhp
0.35
0.40
0.45
0.52
0.59
0.66
0.75
0.84
0.94

LEGEND
Brake Horsepower Input to Fan
Input Watts to Motor

*Motor drive range: 1075 to 1455 rpm. All other rpms require field-supplied
drive.

192

NOTES:
1. Boldface indicates field-supplied drive is required.
2. Maximum continuous bhp is 2.40.
3. See page 187 for general fan performance notes.

FAN PERFORMANCE HORIZONTAL DISCHARGE UNITS (cont)


50HJ006 (5 TONS) STANDARD MOTOR (BELT DRIVE) SINGLE PHASE*
External Static Pressure (in. wg)
Airflow
0.2
0.4
0.6
(Cfm)
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
1500
724
0.33
295
837
0.45
402
937
0.59
524
1028
1600
757
0.39
343
866
0.51
455
962
0.65
580
1050
1700
790
0.45
398
894
0.58
514
988
0.72
643
1074
1800
823
0.52
458
924
0.65
579
1015
0.80
712
1099
1900
857
0.59
525
955
0.73
650
1043
0.89
787
1125
2000
892
0.67
599
986
0.82
729
1072
0.98
870
1151
2100
927
0.77
680
1017
0.92
815
1101
1.08
960
1178
2200
962
0.87
769
1050
1.02
909
1131
1.19
1059

2300
997
0.97
865
1082
1.14
1010

2400
1033
1.09
970
1115
1.26
1120

2500
1069
1.22
1084

0.8
Bhp
0.74
0.81
0.88
0.96
1.05
1.15
1.26

Watts
660
719
784
857
936
1022
1116

Rpm
1111
1132
1154
1177
1201

1.0
Bhp
0.91
0.98
1.06
1.14
1.23

Watts
808
870
938
1013
1096

50HJ006 (5 TONS) STANDARD MOTOR (BELT DRIVE) SINGLE PHASE* (cont)


External Static Pressure (in. wg)
Airflow
1.2
1.4
1.6
(Cfm)
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
1500
1188
1.09
970
1261
1.29
1143

1600
1208
1.16
1033

1700
1229
1.24
1103

1800

1900

2000

2100

2200

2300

2400

2500

1.8
Bhp

Watts

Rpm

2.0
Bhp

Watts

Bhp
Watts

LEGEND
Brake Horsepower Input to Fan
Input Watts to Motor

NOTES:
1. Boldface indicates field-supplied drive is required.
2. Maximum continuous bhp is 1.30.
3. See page 187 for general fan performance notes.

*Motor drive range: 1035 to 1460 rpm. All other rpms require field-supplied
drive.

0.8
Bhp
0.74
0.81
0.88
0.96
1.05
1.15
1.26
1.37
1.50
1.63
1.77

Watts
660
719
784
857
936
1022
1116
1218
1329
1448
1576

Rpm
1111
1132
1154
1177
1201
1226
1251
1277
1304
1332
1360

1.0
Bhp
0.91
0.98
1.06
1.14
1.23
1.33
1.44
1.56
1.69
1.83
1.98

Watts
808
870
938
1013
1096
1185
1283
1389
1503
1625
1757

50HJ006 (5 TONS) STANDARD MOTOR (BELT DRIVE) THREE PHASE* (cont)


External Static Pressure (in. wg)
Airflow
1.2
1.4
1.6
(Cfm)
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
1500
1188
1.09
970
1261
1.29
1143
1330
1.49
1327
1395
1600
1208
1.16
1033
1279
1.36
1208
1347
1.57
1394
1412
1700
1229
1.24
1103
1299
1.44
1280
1366
1.65
1468
1429
1800
1250
1.33
1181
1319
1.53
1360
1385
1.74
1549
1448
1900
1273
1.43
1266
1341
1.63
1447
1405
1.84
1638
1467
2000
1296
1.53
1359
1363
1.74
1542
1427
1.95
1736
1488
2100
1320
1.64
1459
1386
1.85
1646
1448
2.07
1842
1508
2200
1345
1.77
1568
1409
1.98
1758
1471
2.20
1956

2300
1371
1.90
1686
1434
2.11
1878
1494
2.34
2080

2400
1397
2.04
1812
1459
2.26
2008

2500
1424
2.19
1948

1.8
Bhp
1.71
1.79
1.88
1.97
2.07
2.18
2.30

Watts
1523
1590
1665
1748
1839
1939
2047

Rpm
1457
1474
1490
1508
1527

2.0
Bhp
1.95
2.02
2.11
2.20
2.31

Watts
1729
1797
1873
1957
2050

Bhp
Watts

LEGEND
Brake Horsepower Input to Fan
Input Watts to Motor

NOTES:
1. Boldface indicates field-supplied drive is required.
2. Maximum continuous bhp is 2.40.
3. See page 187 for general fan performance notes.

*Motor drive range: 1035 to 1460 rpm. All other rpms require field-supplied
drive.

193

50HJ

50HJ006 (5 TONS) STANDARD MOTOR (BELT DRIVE) THREE PHASE*


External Static Pressure (in. wg)
Airflow
0.2
0.4
0.6
(Cfm)
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
1500
724
0.33
295
837
0.45
402
937
0.59
524
1028
1600
757
0.39
343
866
0.51
455
962
0.65
580
1050
1700
790
0.45
398
894
0.58
514
988
0.72
643
1074
1800
823
0.52
458
924
0.65
579
1015
0.80
712
1099
1900
857
0.59
525
955
0.73
650
1043
0.89
787
1125
2000
892
0.67
599
986
0.82
729
1072
0.98
870
1151
2100
927
0.77
680
1017
0.92
815
1101
1.08
960
1178
2200
962
0.87
769
1050
1.02
909
1131
1.19
1059
1206
2300
997
0.97
865
1082
1.14
1010
1161
1.31
1165
1235
2400
1033
1.09
970
1115
1.26
1120
1192
1.44
1279
1264
2500
1069
1.22
1084
1149
1.39
1239
1223
1.58
1403
1293

Performance data 50HJ (cont)


FAN PERFORMANCE HORIZONTAL DISCHARGE UNITS (cont)
50HJ006 (5 TONS) HIGH-STATIC MOTOR (BELT DRIVE)*
External Static Pressure (in. wg)
0.6
Watts
Rpm
Bhp
Watts
Rpm
402
937
0.59
524
1028
455
962
0.65
580
1050
514
988
0.72
643
1074
579
1015
0.80
712
1099
650
1043
0.89
787
1125
729
1072
0.98
870
1151
815
1101
1.08
960
1178
909
1131
1.19
1059
1206
1010
1161
1.31
1165
1235
1120
1192
1.44
1279
1264
1239
1223
1.58
1403
1293

0.8
Bhp
0.74
0.81
0.88
0.96
1.05
1.15
1.26
1.37
1.50
1.63
1.77

Watts
660
719
784
857
936
1022
1116
1218
1329
1448
1576

Rpm
1111
1132
1154
1177
1201
1226
1251
1277
1304
1332
1360

1.0
Bhp
0.91
0.98
1.06
1.14
1.23
1.33
1.44
1.56
1.69
1.83
1.98

Watts
808
870
938
1013
1096
1185
1283
1389
1503
1625
1757

50HJ006 (5 TONS) HIGH-STATIC MOTOR (BELT DRIVE)* (cont)


External Static Pressure (in. wg)
Airflow
1.2
1.4
1.6
(Cfm)
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
1500
1188
1.09
970
1261
1.29
1143
1330
1.49
1327
1395
1600
1208
1.16
1033
1279
1.36
1208
1347
1.57
1394
1412
1700
1229
1.24
1103
1299
1.44
1280
1366
1.65
1468
1429
1800
1250
1.33
1181
1319
1.53
1360
1385
1.74
1549
1448
1900
1273
1.43
1266
1341
1.63
1447
1405
1.84
1638
1467
2000
1296
1.53
1359
1363
1.74
1542
1427
1.95
1736
1488
2100
1320
1.64
1459
1386
1.85
1646
1448
2.07
1842
1508
2200
1345
1.77
1568
1409
1.98
1758
1471
2.20
1956
1530
2300
1371
1.90
1686
1434
2.11
1878
1494
2.34
2080
1553
2400
1397
2.04
1812
1459
2.26
2008
1518
2.49
2213
1576
2500
1424
2.19
1948
1484
2.42
2147
1543
2.65
2355
1599

1.8
Bhp
1.71
1.79
1.88
1.97
2.07
2.18
2.30
2.44
2.58
2.73
2.89

Watts
1523
1590
1665
1748
1839
1939
2047
2164
2290
2425
2571

Rpm
1457
1474
1490
1508
1527
1546
1566
1587
1609

2.0
Bhp
1.95
2.02
2.11
2.20
2.31
2.42
2.55
2.68
2.83

Watts
1729
1797
1873
1957
2050
2151
2262
2380
2509

Airflow
(Cfm)
1500
1600
1700
1800
1900
2000
2100
2200
2300
2400
2500

Bhp
Watts

Rpm
724
757
790
823
857
892
927
962
997
1033
1069

0.2
Bhp
0.33
0.39
0.45
0.52
0.59
0.67
0.77
0.87
0.97
1.09
1.22

Watts
295
343
398
458
525
599
680
769
865
970
1084

Rpm
837
866
894
924
955
986
1017
1050
1082
1115
1149

0.4
Bhp
0.45
0.51
0.58
0.65
0.73
0.82
0.92
1.02
1.14
1.26
1.39

LEGEND
Brake Horsepower Input to Fan
Input Watts to Motor

NOTES:
1. Boldface indicates field-supplied drive is required.
2. Maximum continuous bhp is 2.90.
3. See page 187 for general fan performance notes.

*Motor drive range: 1300 to 1685 rpm. All other rpms require field-supplied
drive.
50HJ007 (6 TONS) STANDARD MOTOR (BELT DRIVE)*
Airflow
(Cfm)
1800
1900
2000
2100
2200
2300
2400
2500
2600
2700
2800
2900
3000

Rpm
822
855
889
923
957
992
1026
1061
1097
1132
1168
1204
1240

0.2
Bhp
0.51
0.59
0.66
0.75
0.85
0.95
1.06
1.19
1.32
1.46
1.61
1.77
1.94

Watts
455
520
591
668
753
845
945
1053
1169
1294
1428
1572
1725

Rpm
927
957
988
1019
1051
1083
1115
1148
1181
1214
1247
1281
1315

0.4
Bhp
0.66
0.74
0.83
0.92
1.03
1.14
1.26
1.39
1.53
1.67
1.83
2.00
2.18

External Static Pressure (in. wg)


0.6
Watts
Rpm
Bhp
Watts
Rpm
589
1018
0.82
728
1100
659
1046
0.91
805
1127
737
1075
1.00
888
1154
821
1104
1.10
979
1182
912
1134
1.21
1077
1210
1011
1164
1.33
1182
1239
1118
1195
1.46
1295
1268
1233
1226
1.59
1416
1297
1356
1257
1.74
1546
1327
1487
1289
1.90
1684
1358
1629
1320
2.06
1832
1388
1779
1353
2.24
1989

1939

0.8
Bhp
0.98
1.08
1.18
1.29
1.40
1.53
1.66
1.81
1.96
2.12
2.30

Watts
873
956
1045
1142
1245
1357
1476
1604
1740
1885
2039

Rpm
1174
1200
1226
1253
1280
1308
1336
1364
1393
1422

1.0
Bhp
1.15
1.25
1.36
1.48
1.60
1.73
1.87
2.02
2.18
2.35

Watts
1024
1113
1208
1310
1419
1537
1662
1796
1938
2089

1.8
Bhp
1.90
2.02
2.15
2.29

Watts
1687
1796
1911
2034

Rpm
1483
1505
1528

2.0
Bhp
2.10
2.23
2.36

Watts
1867
1979
2100

50HJ007 (6 TONS) STANDARD MOTOR (BELT DRIVE)* (cont)

50HJ

Airflow
(Cfm)
1800
1900
2000
2100
2200
2300
2400
2500
2600
2700
2800
2900
3000
Bhp
Watts

Rpm
1244
1268
1294
1320
1346
1372
1400
1427

1.2
Bhp
1.33
1.44
1.55
1.67
1.80
1.94
2.09
2.24

Watts
1182
1275
1376
1483
1598
1721
1852
1992

Rpm
1308
1332
1357
1382
1408
1434
1460

1.4
Bhp
1.51
1.63
1.74
1.87
2.01
2.15
2.31

External Static Pressure (in. wg)


1.6
Watts
Rpm
Bhp
Watts
Rpm
1345
1369
1.70
1513
1427
1443
1393
1.82
1617
1450
1549
1417
1.95
1727
1474
1662
1441
2.08
1845
1498
1782
1466
2.22
1971

1911
1491
2.37
2105

2047

LEGEND
Brake Horsepower Input to Fan
Input Watts to Motor

*Motor drive range: 1120 to 1585 rpm. All other rpms require field-supplied
drive.

194

NOTES:
1. Boldface indicates field-supplied drive is required.
2. Maximum continuous bhp is 2.40.
3. See page 187 for general fan performance notes.

FAN PERFORMANCE HORIZONTAL DISCHARGE UNITS (cont)


50HJ007 (6 TONS) HIGH-STATIC MOTOR (BELT DRIVE)*
External Static Pressure (in. wg)
0.6
Watts
Rpm
Bhp
Watts
Rpm
589
1018
0.82
728
1100
659
1046
0.91
805
1127
737
1075
1.00
888
1154
821
1104
1.10
979
1182
912
1134
1.21
1077
1210
1011
1164
1.33
1182
1239
1118
1195
1.46
1295
1268
1233
1226
1.59
1416
1297
1356
1257
1.74
1546
1327
1487
1289
1.90
1684
1358
1629
1320
2.06
1832
1388
1779
1353
2.24
1989
1419
1939
1385
2.43
2156
1451

0.8
Bhp
0.98
1.08
1.18
1.29
1.40
1.53
1.66
1.81
1.96
2.12
2.30
2.48
2.68

Watts
873
956
1045
1142
1245
1357
1476
1604
1740
1885
2039
2202
2376

Rpm
1174
1200
1226
1253
1280
1308
1336
1364
1393
1422
1452
1482

1.0
Bhp
1.15
1.25
1.36
1.48
1.60
1.73
1.87
2.02
2.18
2.35
2.53
2.72

Watts
1024
1113
1208
1310
1419
1537
1662
1796
1938
2089
2249
2419

50HJ007 (6 TONS) HIGH-STATIC MOTOR (BELT DRIVE)* (cont)


External Static Pressure (in. wg)
Airflow
1.2
1.4
1.6
(Cfm)
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
1800
1244
1.33
1182
1308
1.51
1345
1369
1.70
1513
1427
1900
1268
1.44
1275
1332
1.63
1443
1393
1.82
1617
1450
2000
1294
1.55
1376
1357
1.74
1549
1417
1.95
1727
1474
2100
1320
1.67
1483
1382
1.87
1662
1441
2.08
1845
1498
2200
1346
1.80
1598
1408
2.01
1782
1466
2.22
1971
1522
2300
1372
1.94
1721
1434
2.15
1911
1491
2.37
2105
1547
2400
1400
2.09
1852
1460
2.31
2047
1517
2.53
2247
1572
2500
1427
2.24
1992
1487
2.47
2192
1543
2.70
2398

2600
1455
2.41
2140
1514
2.64
2346
1570
2.88
2557

2700
1483
2.59
2297
1541
2.83
2509

2800
1512
2.77
2463

2900
1541
2.97
2640

3000

1.8
Bhp
1.90
2.02
2.15
2.29
2.44
2.59
2.76

Watts
1687
1796
1911
2034
2165
2304
2451

Rpm
1483
1505
1528
1552
1575
1600

2.0
Bhp
2.10
2.23
2.36
2.51
2.66
2.82

Watts
1867
1979
2100
2227
2363
2507

Airflow
(Cfm)
1800
1900
2000
2100
2200
2300
2400
2500
2600
2700
2800
2900
3000

Bhp
Watts

Rpm
822
855
889
923
957
992
1026
1061
1097
1132
1168
1204
1240

0.2
Bhp
0.51
0.59
0.66
0.75
0.85
0.95
1.06
1.19
1.32
1.46
1.61
1.77
1.94

Watts
455
520
591
668
753
845
945
1053
1169
1294
1428
1572
1725

Rpm
927
957
988
1019
1051
1083
1115
1148
1181
1214
1247
1281
1315

0.4
Bhp
0.66
0.74
0.83
0.92
1.03
1.14
1.26
1.39
1.53
1.67
1.83
2.00
2.18

LEGEND
Brake Horsepower Input to Fan
Input Watts to Motor

NOTES:
1. Boldface indicates field-supplied drive is required.
2. Maximum continuous bhp is 2.90.
3. See page 187 for general fan performance notes.

*Motor drive range: 1300 to 1685 rpm. All other rpms require field-supplied
drive.

50HJ
195

Performance data 50HJ (cont)


FAN PERFORMANCE HORIZONTAL DISCHARGE UNITS (cont)
50HJ008 (71/2 TONS) STANDARD MOTOR (BELT DRIVE)*
Airflow
(Cfm)
2250
2300
2400
2500
2550
2600
2700
2800
2900
3000
3100
3200
3300
3400
3500
3600
3700
3750

Rpm
465
471
483
495
501
507
519
532
544
557
570
583
596
609
622
635
649
655

0.2
Bhp
0.43
0.45
0.49
0.54
0.56
0.59
0.64
0.70
0.75
0.82
0.88
0.95
1.03
1.10
1.19
1.27
1.36
1.41

Watts
402
421
461
503
526
549
597
649
703
761
823
888
957
1030
1106
1187
1272
1316

Rpm
555
560
571
581
587
592
603
614
625
637
648
660
672
684
696
708
720
726

0.4
Bhp
0.64
0.66
0.71
0.77
0.79
0.82
0.88
0.95
1.01
1.08
1.16
1.23
1.32
1.40
1.49
1.59
1.69
1.74

External Static Pressure (in. wg)


0.6
Watts
Rpm
Bhp
Watts
Rpm
596
629
0.86
802
694
618
634
0.89
828
699
665
644
0.94
881
708
715
654
1.01
937
717
740
659
1.04
967
722
767
664
1.07
996
727
823
674
1.14
1059
737
882
684
1.21
1125
746
944
695
1.28
1194
756
1009
705
1.36
1266
766
1079
716
1.44
1342
776
1151
727
1.53
1422
787
1228
738
1.61
1506
797
1308
749
1.71
1593
808
1392
760
1.81
1685
818
1481
771
1.91
1781
829
1573
783
2.02
1881
840
1621
789
2.07
1932
845

0.8
Bhp
1.10
1.13
1.19
1.26
1.29
1.33
1.40
1.48
1.56
1.64
1.73
1.82
1.92
2.02
2.13
2.24
2.35
2.41

Watts
1021
1050
1109
1171
1204
1237
1306
1378
1453
1533
1615
1702
1792
1887
1985
2088
2195
2250

Rpm
753
757
766
775
779
784
793
803
812
822
831
841
851
861
872
882
892
897

1.0
Bhp
1.34
1.38
1.45
1.52
1.56
1.60
1.68
1.76
1.85
1.94
2.03
2.13
2.24
2.35
2.46
2.58
2.70
2.76

Watts
1252
1283
1348
1416
1452
1488
1563
1641
1723
1808
1897
1991
2088
2188
2294
2403
2517
2575

1.8
Bhp
2.45
2.49
2.58
2.68
2.73
2.78
2.88

Watts
2282
2323
2410
2499
2545
2592
2689

Rpm
988
992
1000

2.0
Bhp
2.75
2.80
2.89

Watts
2564
2607
2698

50HJ008 (71/2 TONS) STANDARD MOTOR (BELT DRIVE)* (cont)


Airflow
(Cfm)
2250
2300
2400
2500
2550
2600
2700
2800
2900
3000
3100
3200
3300
3400
3500
3600
3700
3750
Bhp
Watts

Rpm
806
811
819
828
832
836
845
854
864
873
882
892
901
911
921

1.2
Bhp
1.60
1.64
1.71
1.79
1.83
1.88
1.96
2.05
2.15
2.24
2.35
2.45
2.56
2.68
2.80

Watts
1494
1528
1599
1672
1710
1749
1830
1914
2002
2093
2189
2288
2391
2499
2610

Rpm
856
860
868
877
881
885
894
903
912
921
930
939
948

1.4
Bhp
1.87
1.91
1.99
2.08
2.12
2.17
2.26
2.36
2.46
2.56
2.67
2.78
2.90

External Static Pressure (in. wg)


1.6
Watts
Rpm
Bhp
Watts
Rpm
1747
903
2.15
2009
947
1784
907
2.20
2048
950
1859
915
2.28
2129
958
1938
923
2.37
2214
966
1979
927
2.42
2258
971
2021
931
2.47
2302
975
2107
940
2.57
2394
983
2197
948
2.67
2488

2290
957
2.77
2587

2388
966
2.89
2691

2489

2595

2704

LEGEND
Brake Horsepower Input to Fan
Input Watts to Motor

50HJ

*Motor drive range: 840 to 1085 rpm. All other rpms require field-supplied
drive.

196

NOTES:
1. Boldface indicates field-supplied drive is required.
2. Maximum continuous bhp is 2.90.
3. See page 187 for general fan performance notes.

FAN PERFORMANCE HORIZONTAL DISCHARGE UNITS (cont)


50HJ008 (71/2 TONS) HIGH-STATIC MOTOR (BELT DRIVE)*
Airflow
(Cfm)
2250
2300
2400
2500
2550
2600
2700
2800
2900
3000
3100
3200
3300
3400
3500
3600
3700
3750

Rpm
465
471
483
495
501
507
519
532
544
557
570
583
596
609
622
635
649
655

0.2
Bhp
0.43
0.45
0.49
0.54
0.56
0.59
0.64
0.70
0.75
0.82
0.88
0.95
1.03
1.10
1.19
1.27
1.36
1.41

Watts
402
421
461
503
526
549
597
649
703
761
823
888
957
1030
1106
1187
1272
1316

Rpm
555
560
571
581
587
592
603
614
625
637
648
660
672
684
696
708
720
726

0.4
Bhp
0.64
0.66
0.71
0.77
0.79
0.82
0.88
0.95
1.01
1.08
1.16
1.23
1.32
1.40
1.49
1.59
1.69
1.74

External Static Pressure (in. wg)


0.6
Watts
Rpm
Bhp
Watts
Rpm
596
629
0.86
802
694
618
634
0.89
828
699
665
644
0.94
881
708
715
654
1.01
937
717
740
659
1.04
967
722
767
664
1.07
996
727
823
674
1.14
1059
737
882
684
1.21
1125
746
944
695
1.28
1194
756
1009
705
1.36
1266
766
1079
716
1.44
1342
776
1151
727
1.53
1422
787
1228
738
1.61
1506
797
1308
749
1.71
1593
808
1392
760
1.81
1685
818
1481
771
1.91
1781
829
1573
783
2.02
1881
840
1621
789
2.07
1932
845

0.8
Bhp
1.10
1.13
1.19
1.26
1.29
1.33
1.40
1.48
1.56
1.64
1.73
1.82
1.92
2.02
2.13
2.24
2.35
2.41

Watts
1021
1050
1109
1171
1204
1237
1306
1378
1453
1533
1615
1702
1792
1887
1985
2088
2195
2250

Rpm
753
757
766
775
779
784
793
803
812
822
831
841
851
861
872
882
892
897

1.0
Bhp
1.34
1.38
1.45
1.52
1.56
1.60
1.68
1.76
1.85
1.94
2.03
2.13
2.24
2.35
2.46
2.58
2.70
2.76

Watts
1252
1283
1348
1416
1452
1488
1563
1641
1723
1808
1897
1991
2088
2188
2294
2403
2517
2575

1.8
Bhp
2.45
2.49
2.58
2.68
2.73
2.78
2.88
2.99
3.10
3.22
3.34
3.47
3.60
3.73
3.87
4.01
4.16

Watts
2282
2323
2410
2499
2545
2592
2689
2790
2894
3003
3115
3233
3353
3479
3608
3743
3882

Rpm
988
992
1000
1008
1012
1016
1024
1032
1041
1049
1057
1066
1075
1084

2.0
Bhp
2.75
2.80
2.89
3.00
3.05
3.10
3.21
3.32
3.44
3.56
3.69
3.82
3.96
4.10

Watts
2564
2607
2698
2793
2842
2891
2993
3099
3209
3323
3441
3564
3690
3821

50HJ008 (71/2 TONS) HIGH-STATIC MOTOR (BELT DRIVE)* (cont)


Airflow
(Cfm)
2250
2300
2400
2500
2550
2600
2700
2800
2900
3000
3100
3200
3300
3400
3500
3600
3700
3750
Bhp
Watts

Rpm
806
811
819
828
832
836
845
854
864
873
882
892
901
911
921
931
941
946

1.2
Bhp
1.60
1.64
1.71
1.79
1.83
1.88
1.96
2.05
2.15
2.24
2.35
2.45
2.56
2.68
2.80
2.92
3.05
3.12

Watts
1494
1528
1599
1672
1710
1749
1830
1914
2002
2093
2189
2288
2391
2499
2610
2726
2847
2908

Rpm
856
860
868
877
881
885
894
903
912
921
930
939
948
958
967
977
987
992

1.4
Bhp
1.87
1.91
1.99
2.08
2.12
2.17
2.26
2.36
2.46
2.56
2.67
2.78
2.90
3.02
3.15
3.28
3.41
3.48

External Static Pressure (in. wg)


1.6
Watts
Rpm
Bhp
Watts
Rpm
1747
903
2.15
2009
947
1784
907
2.20
2048
950
1859
915
2.28
2129
958
1938
923
2.37
2214
966
1979
927
2.42
2258
971
2021
931
2.47
2302
975
2107
940
2.57
2394
983
2197
948
2.67
2488
991
2290
957
2.77
2587
1000
2388
966
2.89
2691
1008
2489
975
3.00
2798
1017
2595
984
3.12
2909
1026
2704
993
3.24
3024
1035
2817
1002
3.37
3144
1044
2935
1011
3.50
3268
1053
3057
1021
3.64
3396
1062
3184
1030
3.78
3529
1071
3249
1035
3.86
3597

LEGEND
Brake Horsepower Input to Fan
Input Watts to Motor

NOTES:
1. Boldface indicates field-supplied drive is required.
2. Maximum continuous bhp is 4.20.
3. See page 187 for general fan performance notes.

*Motor drive range: 860 to 1080 rpm. All other rpms require field-supplied
drive.

50HJ
197

Performance data 50HJ (cont)


FAN PERFORMANCE HORIZONTAL DISCHARGE UNITS (cont)
50HJ009 (81/2 TONS) STANDARD MOTOR (BELT DRIVE)*
Airflow
(Cfm)
2500
2600
2700
2800
2900
3000
3100
3200
3300
3400
3500
3600
3700
3800
3900
4000
4100
4200
4300

Rpm
462
474
486
498
510
523
536
549
562
575
588
601
614
628
641
655
668
682
696

0.2
Bhp
0.37
0.41
0.45
0.49
0.53
0.58
0.63
0.68
0.74
0.80
0.86
0.93
1.00
1.07
1.15
1.23
1.31
1.40
1.49

Watts
348
381
417
456
497
541
587
637
689
744
802
864
929
997
1069
1144
1223
1305
1392

Rpm
541
551
561
571
581
592
603
614
626
637
649
661
673
685
697
709
722
734
747

0.4
Bhp
0.50
0.54
0.58
0.63
0.68
0.73
0.78
0.84
0.90
0.96
1.03
1.10
1.17
1.25
1.33
1.42
1.51
1.60
1.70

External Static Pressure (in. wg)


0.6
Watts
Rpm
Bhp
Watts
Rpm
467
614
0.64
594
681
505
622
0.68
635
688
545
630
0.73
679
695
587
639
0.78
725
702
632
648
0.83
774
710
680
657
0.88
825
718
730
666
0.94
879
726
783
676
1.00
936
735
839
686
1.07
996
743
898
696
1.14
1059
752
961
707
1.21
1125
762
1026
717
1.28
1194
771
1095
728
1.36
1267
781
1167
739
1.44
1343
791
1243
750
1.53
1423
801
1322
761
1.61
1506
812
1405
773
1.71
1593
822
1492
784
1.80
1683
833
1582
796
1.91
1777
844

0.8
Bhp
0.78
0.83
0.88
0.93
0.99
1.05
1.11
1.17
1.24
1.31
1.39
1.47
1.55
1.64
1.72
1.82
1.92
2.02
2.12

Watts
728
773
820
870
922
977
1035
1096
1159
1226
1296
1369
1445
1525
1608
1695
1786
1880
1979

Rpm
744
750
756
762
768
775
783
790
798
806
815
823
832
841
850
860
870
880
890

1.0
Bhp
0.93
0.98
1.04
1.09
1.15
1.22
1.28
1.35
1.42
1.50
1.58
1.66
1.75
1.84
1.93
2.03
2.13
2.23
2.34

Watts
868
916
967
1020
1076
1135
1196
1260
1328
1398
1472
1548
1629
1712
1799
1890
1984
2082
2184

1.8
Bhp
1.59
1.65
1.72
1.79
1.87
1.95
2.03
2.11
2.20
2.29
2.38
2.48
2.58
2.69
2.80

Watts
1479
1541
1606
1673
1742
1815
1891
1969
2051
2135
2223
2314
2409
2507
2608

Rpm
1017
1018
1021
1023
1026
1029
1033
1037
1041
1046
1051
1056
1062

2.0
Bhp
1.76
1.83
1.90
1.98
2.06
2.14
2.23
2.31
2.40
2.50
2.60
2.70
2.80

Watts
1642
1708
1776
1847
1920
1996
2075
2157
2242
2331
2422
2516
2615

50HJ009 (81/2 TONS) STANDARD MOTOR (BELT DRIVE)* (cont)


Airflow
(Cfm)
2500
2600
2700
2800
2900
3000
3100
3200
3300
3400
3500
3600
3700
3800
3900
4000
4100
4200
4300
Bhp
Watts

Rpm
804
809
813
819
824
830
837
843
850
858
865
873
881
889
898
907
916
925
934

1.2
Bhp
1.09
1.14
1.20
1.26
1.32
1.39
1.46
1.53
1.61
1.69
1.77
1.86
1.95
2.04
2.14
2.24
2.35
2.45
2.57

Watts
1013
1065
1119
1176
1235
1298
1363
1431
1502
1576
1653
1733
1816
1904
1995
2089
2187
2289
2395

Rpm
861
864
869
873
878
883
889
894
901
907
914
921
928
936
944
952
960
969
978

1.4
Bhp
1.25
1.31
1.37
1.43
1.50
1.57
1.65
1.72
1.80
1.88
1.97
2.06
2.16
2.25
2.35
2.46
2.57
2.68
2.80

External Static Pressure (in. wg)


1.6
Watts
Rpm
Bhp
Watts
Rpm
1164
915
1.41
1319
967
1219
918
1.48
1378
969
1277
921
1.54
1439
972
1337
925
1.61
1503
975
1400
929
1.68
1569
978
1466
934
1.76
1638
982
1534
938
1.83
1710
986
1606
944
1.91
1785
991
1680
949
2.00
1863
996
1758
955
2.09
1944
1001
1838
961
2.18
2029
1007
1922
967
2.27
2116
1012
2010
974
2.37
2207
1019
2100
981
2.47
2302
1025
2195
988
2.57
2399
1032
2293
996
2.68
2501

2395
1004
2.80
2607

2500

2610

LEGEND
Brake Horsepower Input to Fan
Input Watts to Motor

50HJ

*Motor drive range: 840 to 1085 rpm. All other rpms require field-supplied
drive.

198

NOTES:
1. Boldface indicates field-supplied drive is required.
2. Maximum continuous bhp is 2.90.
3. See page 187 for general fan performance notes.

FAN PERFORMANCE HORIZONTAL DISCHARGE UNITS (cont)


50HJ009 (81/2 TONS) HIGH-STATIC MOTOR (BELT DRIVE)*
Airflow
(Cfm)
2500
2600
2700
2800
2900
3000
3100
3200
3300
3400
3500
3600
3700
3800
3900
4000
4100
4200
4300

Rpm
462
474
486
498
510
523
536
549
562
575
588
601
614
628
641
655
668
682
696

0.2
Bhp
0.37
0.41
0.45
0.49
0.53
0.58
0.63
0.68
0.74
0.80
0.86
0.93
1.00
1.07
1.15
1.23
1.31
1.40
1.49

Watts
348
381
417
456
497
541
587
637
689
744
802
864
929
997
1069
1144
1223
1305
1392

Rpm
541
551
561
571
581
592
603
614
626
637
649
661
673
685
697
709
722
734
747

0.4
Bhp
0.50
0.54
0.58
0.63
0.68
0.73
0.78
0.84
0.90
0.96
1.03
1.10
1.17
1.25
1.33
1.42
1.51
1.60
1.70

External Static Pressure (in. wg)


0.6
Watts
Rpm
Bhp
Watts
Rpm
467
614
0.64
594
681
505
622
0.68
635
688
545
630
0.73
679
695
587
639
0.78
725
702
632
648
0.83
774
710
680
657
0.88
825
718
730
666
0.94
879
726
783
676
1.00
936
735
839
686
1.07
996
743
898
696
1.14
1059
752
961
707
1.21
1125
762
1026
717
1.28
1194
771
1095
728
1.36
1267
781
1167
739
1.44
1343
791
1243
750
1.53
1423
801
1322
761
1.61
1506
812
1405
773
1.71
1593
822
1492
784
1.80
1683
833
1582
796
1.91
1777
844

0.8
Bhp
0.78
0.83
0.88
0.93
0.99
1.05
1.11
1.17
1.24
1.31
1.39
1.47
1.55
1.64
1.72
1.82
1.92
2.02
2.12

Watts
728
773
820
870
922
977
1035
1096
1159
1226
1296
1369
1445
1525
1608
1695
1786
1880
1979

Rpm
744
750
756
762
768
775
783
790
798
806
815
823
832
841
850
860
870
880
890

1.0
Bhp
0.93
0.98
1.04
1.09
1.15
1.22
1.28
1.35
1.42
1.50
1.58
1.66
1.75
1.84
1.93
2.03
2.13
2.23
2.34

Watts
868
916
967
1020
1076
1135
1196
1260
1328
1398
1472
1548
1629
1712
1799
1890
1984
2082
2184

1.8
Bhp
1.59
1.65
1.72
1.79
1.87
1.95
2.03
2.11
2.20
2.29
2.38
2.48
2.58
2.69
2.80
2.91
3.03
3.15
3.27

Watts
1479
1541
1606
1673
1742
1815
1891
1969
2051
2135
2223
2314
2409
2507
2608
2713
2822
2935
3052

Rpm
1017
1018
1021
1023
1026
1029
1033
1037
1041
1046
1051
1056
1062
1068
1074
1080
1087
1094
1101

2.0
Bhp
1.76
1.83
1.90
1.98
2.06
2.14
2.23
2.31
2.40
2.50
2.60
2.70
2.80
2.91
3.03
3.14
3.26
3.39
3.52

Watts
1642
1708
1776
1847
1920
1996
2075
2157
2242
2331
2422
2516
2615
2716
2821
2930
3042
3159
3279

50HJ009 (81/2 TONS) HIGH-STATIC MOTOR (BELT DRIVE)* (cont)


Airflow
(Cfm)
2500
2600
2700
2800
2900
3000
3100
3200
3300
3400
3500
3600
3700
3800
3900
4000
4100
4200
4300
Bhp
Watts

Rpm
804
809
813
819
824
830
837
843
850
858
865
873
881
889
898
907
916
925
934

1.2
Bhp
1.09
1.14
1.20
1.26
1.32
1.39
1.46
1.53
1.61
1.69
1.77
1.86
1.95
2.04
2.14
2.24
2.35
2.45
2.57

Watts
1013
1065
1119
1176
1235
1298
1363
1431
1502
1576
1653
1733
1816
1904
1995
2089
2187
2289
2395

Rpm
861
864
869
873
878
883
889
894
901
907
914
921
928
936
944
952
960
969
978

1.4
Bhp
1.25
1.31
1.37
1.43
1.50
1.57
1.65
1.72
1.80
1.88
1.97
2.06
2.16
2.25
2.35
2.46
2.57
2.68
2.80

External Static Pressure (in. wg)


1.6
Watts
Rpm
Bhp
Watts
Rpm
1164
915
1.41
1319
967
1219
918
1.48
1378
969
1277
921
1.54
1439
972
1337
925
1.61
1503
975
1400
929
1.68
1569
978
1466
934
1.76
1638
982
1534
938
1.83
1710
986
1606
944
1.91
1785
991
1680
949
2.00
1863
996
1758
955
2.09
1944
1001
1838
961
2.18
2029
1007
1922
967
2.27
2116
1012
2010
974
2.37
2207
1019
2100
981
2.47
2302
1025
2195
988
2.57
2399
1032
2293
996
2.68
2501
1038
2395
1004
2.80
2607
1046
2500
1011
2.91
2716
1053
2610
1020
3.03
2828
1061

LEGEND
Brake Horsepower Input to Fan
Input Watts to Motor

NOTES:
1. Boldface indicates field-supplied drive is required.
2. Maximum continuous bhp is 4.20.
3. See page 187 for general fan performance notes.

*Motor drive range: 860 to 1080 rpm. All other rpms require field-supplied
drive.

50HJ
199

Performance data 50HJ (cont)


FAN PERFORMANCE HORIZONTAL DISCHARGE UNITS (cont)
50HJ012 (10 TONS) STANDARD MOTOR (BELT DRIVE)*
Airflow
(Cfm)
3000
3100
3200
3300
3400
3500
3600
3700
3800
3900
4000
4100
4200
4300
4400
4500
4600
4700
4800
4900
5000

Rpm
523
536
549
562
575
588
601
614
628
641
655
668
682
696
710
723
737
751
765
779
793

0.2
Bhp
0.58
0.63
0.68
0.74
0.80
0.86
0.93
1.00
1.07
1.15
1.23
1.31
1.40
1.49
1.59
1.69
1.80
1.91
2.02
2.14
2.26

Watts
541
587
637
689
744
802
864
929
997
1069
1144
1223
1305
1392
1482
1577
1675
1778
1885
1996
2112

Rpm
592
603
614
626
637
649
661
673
685
697
709
722
734
747
760
773
785
798
812
825
838

0.4
Bhp
0.73
0.78
0.84
0.90
0.96
1.03
1.10
1.17
1.25
1.33
1.42
1.51
1.60
1.70
1.80
1.90
2.01
2.13
2.25
2.37
2.50

External Static Pressure (in. wg)


0.6
Watts
Rpm
Bhp
Watts
Rpm
680
657
0.88
825
718
730
666
0.94
879
726
783
676
1.00
936
735
839
686
1.07
996
743
898
696
1.14
1059
752
961
707
1.21
1125
762
1026
717
1.28
1194
771
1095
728
1.36
1267
781
1167
739
1.44
1343
791
1243
750
1.53
1423
801
1322
761
1.61
1506
812
1405
773
1.71
1593
822
1492
784
1.80
1683
833
1582
796
1.91
1777
844
1677
808
2.01
1876
855
1775
820
2.12
1978
866
1877
832
2.24
2085
877
1984
844
2.35
2195
889
2095
856
2.48
2310
900
2210
869
2.61
2430
912
2330
881
2.74
2554
923

0.8
Bhp
1.05
1.11
1.17
1.24
1.31
1.39
1.47
1.55
1.64
1.72
1.82
1.92
2.02
2.12
2.23
2.35
2.46
2.59
2.71
2.85
2.98

Watts
977
1035
1096
1159
1226
1296
1369
1445
1525
1608
1695
1786
1880
1979
2081
2187
2297
2412
2531
2654
2782

Rpm
775
783
790
798
806
815
823
832
841
850
860
870
880
890
900
910
921
932
942
953
965

1.0
Bhp
1.22
1.28
1.35
1.42
1.50
1.58
1.66
1.75
1.84
1.93
2.03
2.13
2.23
2.34
2.46
2.57
2.70
2.82
2.95
3.09
3.23

Watts
1135
1196
1260
1328
1398
1472
1548
1629
1712
1799
1890
1984
2082
2184
2290
2400
2514
2633
2756
2883
3014

1.8
Bhp
1.95
2.03
2.11
2.20
2.29
2.38
2.48
2.58
2.69
2.80
2.91
3.03
3.15
3.27
3.40
3.54
3.67

Watts
1815
1891
1969
2051
2135
2223
2314
2409
2507
2608
2713
2822
2935
3052
3173
3297
3426

Rpm
1029
1033
1037
1041
1046
1051
1056
1062
1068
1074
1080
1087
1094
1101
1108

2.0
Bhp
2.14
2.23
2.31
2.40
2.50
2.60
2.70
2.80
2.91
3.03
3.14
3.26
3.39
3.52
3.65

Watts
1996
2075
2157
2242
2331
2422
2516
2615
2716
2821
2930
3042
3159
3279
3403

50HJ012 (10 TONS) STANDARD MOTOR (BELT DRIVE)* (cont)


Airflow
(Cfm)
3000
3100
3200
3300
3400
3500
3600
3700
3800
3900
4000
4100
4200
4300
4400
4500
4600
4700
4800
4900
5000
Bhp
Watts

Rpm
830
837
843
850
858
865
873
881
889
898
907
916
925
934
944
954
963
974
984
994
1005

1.2
Bhp
1.39
1.46
1.53
1.61
1.69
1.77
1.86
1.95
2.04
2.14
2.24
2.35
2.45
2.57
2.69
2.81
2.93
3.07
3.20
3.34
3.49

Watts
1298
1363
1431
1502
1576
1653
1733
1816
1904
1995
2089
2187
2289
2395
2504
2618
2736
2858
2985
3116
3251

Rpm
883
889
894
901
907
914
921
928
936
944
952
960
969
978
986
996
1005
1014
1024
1034

1.4
Bhp
1.57
1.65
1.72
1.80
1.88
1.97
2.06
2.16
2.25
2.35
2.46
2.57
2.68
2.80
2.92
3.05
3.18
3.31
3.45
3.60

External Static Pressure (in. wg)


1.6
Watts
Rpm
Bhp
Watts
Rpm
1466
934
1.76
1638
982
1534
938
1.83
1710
986
1606
944
1.91
1785
991
1680
949
2.00
1863
996
1758
955
2.09
1944
1001
1838
961
2.18
2029
1007
1922
967
2.27
2116
1012
2010
974
2.37
2207
1019
2100
981
2.47
2302
1025
2195
988
2.57
2399
1032
2293
996
2.68
2501
1038
2395
1004
2.80
2607
1046
2500
1011
2.91
2716
1053
2610
1020
3.03
2828
1061
2723
1028
3.16
2946
1068
2840
1037
3.29
3067
1076
2962
1045
3.42
3192
1085
3088
1054
3.56
3322

3219

3353

LEGEND
Brake Horsepower Input to Fan
Input Watts to Motor

50HJ

*Motor drive range: 860 to 1080 rpm. All other rpms require field-supplied
drive.

200

NOTES:
1. Boldface indicates field-supplied drive is required.
2. Maximum continuous bhp is 3.70.
3. See page 187 for general fan performance notes.

FAN PERFORMANCE HORIZONTAL DISCHARGE UNITS (cont)


50HJ012 (10 TONS) HIGH-STATIC MOTOR (BELT DRIVE)*
External Static Pressure (in. wg)
0.6
Watts
Rpm
Bhp
Watts
Rpm
680
657
0.88
825
718
730
666
0.94
879
726
783
676
1.00
936
735
839
686
1.07
996
743
898
696
1.14
1059
752
961
707
1.21
1125
762
1026
717
1.28
1194
771
1095
728
1.36
1267
781
1167
739
1.44
1343
791
1243
750
1.53
1423
801
1322
761
1.61
1506
812
1405
773
1.71
1593
822
1492
784
1.80
1683
833
1582
796
1.91
1777
844
1677
808
2.01
1876
855
1775
820
2.12
1978
866
1877
832
2.24
2085
877
1984
844
2.35
2195
889
2095
856
2.48
2310
900
2210
869
2.61
2430
912
2330
881
2.74
2554
923

0.8
Bhp
1.05
1.11
1.17
1.24
1.31
1.39
1.47
1.55
1.64
1.72
1.82
1.92
2.02
2.12
2.23
2.35
2.46
2.59
2.71
2.85
2.98

Watts
977
1035
1096
1159
1226
1296
1369
1445
1525
1608
1695
1786
1880
1979
2081
2187
2297
2412
2531
2654
2782

Rpm
775
783
790
798
806
815
823
832
841
850
860
870
880
890
900
910
921
932
942
953
965

1.0
Bhp
1.22
1.28
1.35
1.42
1.50
1.58
1.66
1.75
1.84
1.93
2.03
2.13
2.23
2.34
2.46
2.57
2.70
2.82
2.95
3.09
3.23

Watts
1135
1196
1260
1328
1398
1472
1548
1629
1712
1799
1890
1984
2082
2184
2290
2400
2514
2633
2756
2883
3014

50HJ012 (10 TONS) HIGH-STATIC MOTOR (BELT DRIVE)* (cont)


External Static Pressure (in. wg)
Airflow
1.2
1.4
1.6
(Cfm)
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
3000
830
1.39
1298
883
1.57
1466
934
1.76
1638
982
3100
837
1.46
1363
889
1.65
1534
938
1.83
1710
986
3200
843
1.53
1431
894
1.72
1606
944
1.91
1785
991
3300
850
1.61
1502
901
1.80
1680
949
2.00
1863
996
3400
858
1.69
1576
907
1.88
1758
955
2.09
1944
1001
3500
865
1.77
1653
914
1.97
1838
961
2.18
2029
1007
3600
873
1.86
1733
921
2.06
1922
967
2.27
2116
1012
3700
881
1.95
1816
928
2.16
2010
974
2.37
2207
1019
3800
889
2.04
1904
936
2.25
2100
981
2.47
2302
1025
3900
898
2.14
1995
944
2.35
2195
988
2.57
2399
1032
4000
907
2.24
2089
952
2.46
2293
996
2.68
2501
1038
4100
916
2.35
2187
960
2.57
2395
1004
2.80
2607
1046
4200
925
2.45
2289
969
2.68
2500
1011
2.91
2716
1053
4300
934
2.57
2395
978
2.80
2610
1020
3.03
2828
1061
4400
944
2.69
2504
986
2.92
2723
1028
3.16
2946
1068
4500
954
2.81
2618
996
3.05
2840
1037
3.29
3067
1076
4600
963
2.93
2736
1005
3.18
2962
1045
3.42
3192
1085
4700
974
3.07
2858
1014
3.31
3088
1054
3.56
3322
1093
4800
984
3.20
2985
1024
3.45
3219
1063
3.71
3456
1102
4900
994
3.34
3116
1034
3.60
3353
1073
3.85
3594
1111
5000
1005
3.49
3251
1044
3.74
3492
1082
4.01
3737
1119

1.8
Bhp
1.95
2.03
2.11
2.20
2.29
2.38
2.48
2.58
2.69
2.80
2.91
3.03
3.15
3.27
3.40
3.54
3.67
3.82
3.96
4.12
4.27

Watts
1815
1891
1969
2051
2135
2223
2314
2409
2507
2608
2713
2822
2935
3052
3173
3297
3426
3560
3697
3839
3986

Rpm
1029
1033
1037
1041
1046
1051
1056
1062
1068
1074
1080
1087
1094
1101
1108
1115
1123
1131
1139
1148
1156

2.0
Bhp
2.14
2.23
2.31
2.40
2.50
2.60
2.70
2.80
2.91
3.03
3.14
3.26
3.39
3.52
3.65
3.79
3.93
4.08
4.23
4.38
4.55

Watts
1996
2075
2157
2242
2331
2422
2516
2615
2716
2821
2930
3042
3159
3279
3403
3531
3664
3801
3943
4088
4238

Airflow
(Cfm)
3000
3100
3200
3300
3400
3500
3600
3700
3800
3900
4000
4100
4200
4300
4400
4500
4600
4700
4800
4900
5000

Bhp
Watts

Rpm
523
536
549
562
575
588
601
614
628
641
655
668
682
696
710
723
737
751
765
779
793

0.2
Bhp
0.58
0.63
0.68
0.74
0.80
0.86
0.93
1.00
1.07
1.15
1.23
1.31
1.40
1.49
1.59
1.69
1.80
1.91
2.02
2.14
2.26

Watts
541
587
637
689
744
802
864
929
997
1069
1144
1223
1305
1392
1482
1577
1675
1778
1885
1996
2112

Rpm
592
603
614
626
637
649
661
673
685
697
709
722
734
747
760
773
785
798
812
825
838

0.4
Bhp
0.73
0.78
0.84
0.90
0.96
1.03
1.10
1.17
1.25
1.33
1.42
1.51
1.60
1.70
1.80
1.90
2.01
2.13
2.25
2.37
2.50

LEGEND
Brake Horsepower Input to Fan
Input Watts to Motor

NOTES:
1. Boldface indicates field-supplied drive is required.
2. Maximum continuous bhp is 5.25.
3. See page 187 for general fan performance notes.

*Motor drive range: 830 to 1130 rpm. All other rpms require field-supplied
drive.

50HJ
201

Performance data 50HJ (cont)


FAN PERFORMANCE HORIZONTAL DISCHARGE UNITS (cont)
50HJ014 (121/2 TONS) STANDARD MOTOR (BELT DRIVE)*
Airflow
(Cfm)
3700
3800
3900
4000
4100
4200
4300
4400
4500
4600
4700
4800
4900
5000
5100
5200
5300
5400
5500
5600
5700
5800
5900
6000
6100
6200
6300

Rpm
614
628
641
655
668
682
696
710
723
737
751
765
779
793
807
821
835
850
864
878
892
907
921
935
949
964
978

0.2
Bhp
1.00
1.07
1.15
1.23
1.31
1.40
1.49
1.59
1.69
1.80
1.91
2.02
2.14
2.26
2.39
2.53
2.67
2.81
2.96
3.12
3.28
3.44
3.61
3.79
3.98
4.16
4.36

Watts
929
997
1069
1144
1223
1305
1392
1482
1577
1675
1778
1885
1996
2112
2232
2357
2487
2622
2762
2906
3055
3211
3370
3536
3707
3883
4066

Rpm
673
685
697
709
722
734
747
760
773
785
798
812
825
838
851
864
878
891
905
918
932
945
959
973
987
1000
1014

0.4
Bhp
1.17
1.25
1.33
1.42
1.51
1.60
1.70
1.80
1.90
2.01
2.13
2.25
2.37
2.50
2.63
2.77
2.91
3.06
3.22
3.38
3.54
3.71
3.89
4.07
4.26
4.45
4.65

External Static Pressure (in. wg)


0.6
Watts
Rpm
Bhp
Watts
Rpm
1095
728
1.36
1267
781
1167
739
1.44
1343
791
1243
750
1.53
1423
801
1322
761
1.61
1506
812
1405
773
1.71
1593
822
1492
784
1.80
1683
833
1582
796
1.91
1777
844
1677
808
2.01
1876
855
1775
820
2.12
1978
866
1877
832
2.24
2085
877
1984
844
2.35
2195
889
2095
856
2.48
2310
900
2210
869
2.61
2430
912
2330
881
2.74
2554
923
2455
894
2.88
2682
935
2584
906
3.02
2815
947
2718
919
3.17
2953
959
2856
932
3.32
3096
971
3000
945
3.48
3242
984
3148
958
3.64
3396
996
3302
971
3.81
3554
1008
3461
984
3.99
3716
1021
3626
997
4.17
3885
1033
3795
1010
4.35
4059
1046
3970
1023
4.54
4238
1059
4151
1036
4.74
4422
1071
4337
1050
4.95
4613
1084

0.8
Bhp
1.55
1.64
1.72
1.82
1.92
2.02
2.12
2.23
2.35
2.46
2.59
2.71
2.85
2.98
3.13
3.27
3.42
3.58
3.74
3.91
4.09
4.26
4.45
4.64
4.84
5.04
5.25

Watts
1445
1525
1608
1695
1786
1880
1979
2081
2187
2297
2412
2531
2654
2782
2914
3050
3193
3339
3491
3648
3810
3976
4149
4326
4510
4698
4892

Rpm
832
841
850
860
870
880
890
900
910
921
932
942
953
965
976
987
999
1010
1022
1034
1045
1057
1069
1082
1094

1.0
Bhp
1.75
1.84
1.93
2.03
2.13
2.23
2.34
2.46
2.57
2.70
2.82
2.95
3.09
3.23
3.38
3.53
3.69
3.85
4.01
4.19
4.36
4.55
4.74
4.93
5.13

Watts
1629
1712
1799
1890
1984
2082
2184
2290
2400
2514
2633
2756
2883
3014
3150
3292
3437
3588
3743
3903
4069
4240
4416
4598
4785

1.8
Bhp
2.58
2.69
2.80
2.91
3.03
3.15
3.27
3.40
3.54
3.67
3.82
3.96
4.12
4.27
4.44
4.60
4.78
4.95
5.14

Watts
2409
2507
2608
2713
2822
2935
3052
3173
3297
3426
3560
3697
3839
3986
4137
4293
4454
4619
4790

Rpm
1062
1068
1074
1080
1087
1094
1101
1108
1115
1123
1131
1139
1148
1156
1165
1174
1183
1192

2.0
Bhp
2.80
2.91
3.03
3.14
3.26
3.39
3.52
3.65
3.79
3.93
4.08
4.23
4.38
4.55
4.71
4.88
5.06
5.24

Watts
2615
2716
2821
2930
3042
3159
3279
3403
3531
3664
3801
3943
4088
4238
4393
4553
4718
4886

50HJ014 (121/2 TONS) STANDARD MOTOR (BELT DRIVE)* (cont)


Airflow
(Cfm)

50HJ

3700
3800
3900
4000
4100
4200
4300
4400
4500
4600
4700
4800
4900
5000
5100
5200
5300
5400
5500
5600
5700
5800
5900
6000
6100
6200
6300
Bhp
Watts

Rpm
881
889
898
907
916
925
934
944
954
963
974
984
994
1005
1015
1026
1037
1048
1059
1070
1082
1093
1105
1116

1.2
Bhp
1.95
2.04
2.14
2.24
2.35
2.45
2.57
2.69
2.81
2.93
3.07
3.20
3.34
3.49
3.64
3.79
3.95
4.12
4.29
4.46
4.65
4.83
5.03
5.23

Watts
1816
1904
1995
2089
2187
2289
2395
2504
2618
2736
2858
2985
3116
3251
3391
3536
3685
3840
3999
4163
4333
4508
4688
4873

Rpm
928
936
944
952
960
969
978
986
996
1005
1014
1024
1034
1044
1054
1064
1075
1085
1096
1106
1117
1128

1.4
Bhp
2.16
2.25
2.35
2.46
2.57
2.68
2.80
2.92
3.05
3.18
3.31
3.45
3.60
3.74
3.90
4.06
4.22
4.39
4.57
4.75
4.93
5.13

External Static Pressure (in. wg)


1.6
Watts
Rpm
Bhp
Watts
Rpm
2010
974
2.37
2207
1019
2100
981
2.47
2302
1025
2195
988
2.57
2399
1032
2293
996
2.68
2501
1038
2395
1004
2.80
2607
1046
2500
1011
2.91
2716
1053
2610
1020
3.03
2828
1061
2723
1028
3.16
2946
1068
2840
1037
3.29
3067
1076
2962
1045
3.42
3192
1085
3088
1054
3.56
3322
1093
3219
1063
3.71
3456
1102
3353
1073
3.85
3594
1111
3492
1082
4.01
3737
1119
3636
1092
4.17
3885
1129
3784
1101
4.33
4037
1138
3938
1111
4.50
4194
1147
4096
1121
4.67
4356
1157
4259
1132
4.85
4523
1167
4427
1142
5.03
4695

4601
1152
5.22
4872

4779

LEGEND
Brake Horsepower Input to Fan
Input Watts to Motor

NOTES:
1. Boldface indicates field-supplied drive is required.
2. Maximum continuous bhp is 5.25.
3. See page 187 for general fan performance notes.

*Motor drive range: 830 to 1130 rpm. All other rpms require field-supplied
drive.

NOTE: REFER TO 50HJ015,017 VERTICAL FAN PERFORMANCE TABLES ON PAGES 186 AND 187 FOR FAN PERFORMANCE WITH HORIZONTAL ADAPTER CURB.

202

FAN PERFORMANCE HORIZONTAL DISCHARGE UNITS (cont)


50HJ020* (18 TONS)
Airflow
(Cfm)

3500
4000
4500
5000
5500
6000
6500
7000
7500
8000
8500

Rpm

0.2
Watts

Bhp

445
484
524
566
608
651
695
740
785
831
878

546
718
923
1166
1450
1777
2152
2576
3051
3581
4167

0.63
0.83
1.06
1.34
1.67
2.04
2.47
2.96
3.51
4.12
4.79

Rpm

0.4
Watts

Available External Static Pressure (in. wg)


0.6
Bhp
Rpm
Watts
Bhp
Rpm

0.8
Watts

Bhp

Rpm

1.0
Watts

Bhp

526
559
596
634
672
712
753
794
836
878
922

712
896
1116
1373
1667
2002
2381
2807
3282
3810
4394

0.82
1.03
1.28
1.58
1.92
2.30
2.74
3.23
3.77
4.38
5.05

681
694
717
747
780
815
852
890
929
969
1008

1102
1280
1508
1781
2099
2459
2863
3312
3807
4352
4948

1.27
1.47
1.73
2.05
2.41
2.83
3.29
3.81
4.38
5.01
5.69

761
763
777
800
829
862
897
933
971
1009
1048

1346
1505
1724
1996
2318
2686
3100
3561
4069
4625
5233

1.55
1.73
1.98
2.30
2.67
3.09
3.57
4.10
4.68
5.32
6.02

Available External Static Pressure (in. wg)


1.6
Bhp
Rpm
Watts
Bhp
Rpm

1.8
Watts

Bhp

Rpm

2.0
Watts

Bhp

2.56
2.84
3.21
3.63
4.12
4.67
5.28
5.94
6.66

3029
3315
3672
4094
4575
5112
5706
6353

3.48
3.81
4.22
4.71
5.26
5.88
6.56
7.31

1077
1087
1105
1128
1156
1187
1220

3606
3950
4364
4843
5382
5980
6634

4.15
4.54
5.02
5.57
6.19
6.88
7.63

603
627
658
692
729
766
805
844
885
925
966

892
1079
1308
1576
1884
2232
2623
3059
3544
4077
4664

1.03
1.24
1.50
1.81
2.17
2.57
3.02
3.52
4.08
4.69
5.36

50HJ020* (18 TONS) (cont)


Airflow
(Cfm)

3500
4000
4500
5000
5500
6000
6500
7000
7500
8000
8500

Rpm

1.2
Watts

Bhp

Rpm

1.4
Watts

833
838
854
878
907
939
974
1010
1047
1085

1759
1961
2226
2546
2918
3339
3809
4328
4896
5515

2.02
2.26
2.56
2.93
3.36
3.84
4.38
4.98
5.63
6.34

900
909
927
952
981
1013
1047
1083
1120

2223
2473
2787
3158
3583
4059
4587
5165
5795

962
964
976
996
1022
1052
1084
1118
1154

LEGEND
Bhp Brake Horsepower Input to Fan
Watts Input Watts to Motor
*Motor drive ranges:
Low Range: Not Used
Mid-Low Range: 647-886 (208/230 and 460-v), 810-1072 (575-v)
Mid-High Range: 897-1139 (208/230 and 460-v), 873-1108 (575-v)
High Range: 1078-1274
All other rpms require field-supplied drive.

2507
2740
3042
3408
3834
4314
4848
5435
6074

2.88
3.15
3.50
3.92
4.41
4.96
5.58
6.25
6.99

1020
1026
1041
1063
1090
1120
1153
1187

NOTES:
1. Maximum continuous bhp is:
Low Range: Not Used
Mid-Low Range: 4.25 (208/230 and 460-v), 3.45 (575-v)
Mid-High Range: 5.75
High Range: 8.63
2. See page 187 for general fan performance notes.

50HJ
203

Performance data 50HJ (cont)


FAN PERFORMANCE HORIZONTAL DISCHARGE UNITS (cont)
50HJ024* (20 TONS)
Airflow
(Cfm)

5,000
5,500
6,000
6,500
7,000
7,500
8,000
8,500
9,000
9,500
10,000

Rpm

0.2
Watts

Bhp

575
619
663
708
753
800
847
894
941
989
1037

1193
1483
1817
2198
2629
3112
3650
4244
4896
5610
6386

1.37
1.71
2.09
2.53
3.02
3.58
4.20
4.88
5.63
6.45
7.34

Rpm

0.4
Watts

Available External Static Pressure (in. wg)


0.6
Bhp
Rpm
Watts
Bhp
Rpm

0.8
Watts

Bhp

Rpm

1.0
Watts

Bhp

642
682
723
765
807
850
894
939
983
1029
1075

1400
1702
2046
2435
2871
3357
3897
4491
5145
5858
6634

1.61
1.96
2.35
2.80
3.30
3.86
4.48
5.17
5.92
6.74
7.63

754
788
825
863
902
942
982
1024
1065
1108
1150

1810
2134
2503
2916
3377
3885
4445
5056
5723
6447
7231

2.08
2.45
2.88
3.35
3.88
4.47
5.11
5.82
6.58
7.41
8.32

808
837
871
906
944
982
1022
1062
1103
1144
1186

2028
2355
2731
3155
3626
4146
4717
5340
6018
6753
7546

2.33
2.71
3.14
3.63
4.17
4.77
5.43
6.14
6.92
7.77
8.68

Available External Static Pressure (in. wg)


1.6
Bhp
Rpm
Watts
Bhp
Rpm

1.8
Watts

Bhp

Rpm

2.0
Watts

Bhp

2.89
3.25
3.69
4.19
4.75
5.37
6.05
6.79
7.59
8.46
9.40

3073
3365
3728
4157
4647
5195
5800
6463
7182
7959
8794

3.53
3.87
4.29
4.78
5.34
5.98
6.67
7.43
8.26
9.15
10.11

1084
1086
1096
1114
1139
1167
1199
1232
1268
1305
1342

3384
3660
4009
4430
4918
5468
6077
6745
7472
8258
9103

3.89
4.21
4.61
5.10
5.66
6.29
6.99
7.76
8.59
9.50
10.47

700
737
776
816
857
898
940
982
1025
1069
1113

1603
1918
2276
2677
3125
3621
4169
4770
5428
6145
6923

1.84
2.21
2.62
3.08
3.59
4.16
4.80
5.49
6.24
7.07
7.96

50HJ024* (20 TONS) (cont)


Airflow
(Cfm)

5,000
5,500
6,000
6,500
7,000
7,500
8,000
8,500
9,000
9,500
10,000

Rpm

1.2
Watts

Bhp

Rpm

1.4
Watts

862
886
916
949
984
1021
1059
1099
1138
1179
1220

2260
2586
2965
3395
3875
4406
4988
5623
6312
7057
7860

2.60
2.97
3.41
3.90
4.46
5.07
5.74
6.47
7.26
8.12
9.04

917
935
960
990
1023
1059
1095
1133
1172
1212
1252

2510
2829
3207
3641
4127
4666
5258
5903
6603
7359
8174

LEGEND
Bhp Brake Horsepower Input to Fan
Watts Input Watts to Motor

50HJ

*Motor drive ranges:


Low Range: 685-939 (208/230 and 460-v), 751-954 (575-v)
Mid-Low Range: 949-1206
Mid-High Range: 941-1176
High Range: 1014-1297
All other rpms require field-supplied drive.

204

972
985
1005
1032
1062
1095
1130
1167
1205
1244
1283

2781
3089
3461
3894
4383
4928
5528
6182
6893
7660
8485

3.20
3.55
3.98
4.48
5.04
5.67
6.36
7.11
7.93
8.81
9.76

1028
1035
1050
1073
1100
1131
1165
1200
1237
1275
1313

NOTES:
1. Maximum continuous bhp is:
Low Range: 4.25 (208/230 and 460-v), 5.75 (575-v)
Mid-Low Range: 5.75
Mid-High Range: 8.63
High Range: 11.50
2. See page 187 for general fan performance notes.

FAN PERFORMANCE HORIZONTAL DISCHARGE UNITS (cont)


50HJ028* (25 TONS)
Airflow
(Cfm)

6,500
7,000
7,500
8,000
8,500
9,000
9,500
10,000
10,500
11,000
11,500
12,000
12,500

Rpm

0.2
Watts

Bhp

Rpm

0.4
Watts

759
810
862
913
965
1017
1069
1121
1173
1226
1278
1331

2,517
3,020
3,581
4,206
4,894
5,651
6,477
7,376
8,350
9,401
10,532
11,745

2.89
3.47
4.12
4.84
5.63
6.50
7.45
8.48
9.60
10.81
12.11
13.51

804
853
903
953
1003
1054
1105
1156
1207
1259
1310

2,753
3,274
3,856
4,500
5,209
5,988
6,834
7,755
8,751
9,823
10,975

Available External Static Pressure (in. wg)


0.6
Bhp
Rpm
Watts
Bhp
Rpm

3.17
3.77
4.43
5.18
5.99
6.89
7.86
8.92
10.06
11.30
12.62

844
891
939
988
1037
1087
1137
1187
1238
1288
1339

2,975
3,509
4,105
4,765
5,491
6,285
7,150
8,089
9,103
10,194
11,366

3.42
4.04
4.72
5.48
6.32
7.23
8.22
9.30
10.47
11.72
13.07

883
928
974
1021
1069
1118
1167
1216
1266
1316
1366

0.8
Watts

Bhp

Rpm

1.0
Watts

Bhp

3,202
3,743
4,348
5,019
5,758
6,567
7,446
8,400
9,430
10,538
11,726

3.68
4.30
5.00
5.77
6.62
7.55
8.56
9.66
10.85
12.12
13.49

922
964
1008
1053
1100
1147
1195
1243
1292
1342

3,445
3,986
4,596
5,274
6,022
6,841
7,733
8,699
9,744
10,866

3.96
4.58
5.29
6.07
6.93
7.87
8.89
10.01
11.21
12.50

1.8
Watts

Bhp

Rpm

2.0
Watts

Bhp

4,701
5,174
5,744
6,403
7,149
7,978
8,890
9,884
10,960

5.41
5.95
6.61
7.36
8.22
9.18
10.22
11.37
12.61

1135
1155
1182
1214
1249
1288
1329
1371

5,103
5,547
6,091
6,733
7,467
8,289
9,198
10,193

5.87
6.38
7.01
7.74
8.59
9.53
10.58
11.72

50HJ028* (25 TONS) (cont)


Airflow
(Cfm)

6,500
7,000
7,500
8,000
8,500
9,000
9,500
10,000
10,500
11,000
11,500
12,000
12,500

Rpm

1.2
Watts

Bhp

Rpm

1.4
Watts

962
1000
1041
1085
1129
1175
1222
1270
1318
1366

3,710
4,245
4,854
5,535
6,289
7,115
8,016
8,993
10,048
11,183

4.27
4.88
5.58
6.37
7.23
8.18
9.22
10.34
11.56
12.86

1003
1037
1075
1116
1159
1204
1249
1296
1343
1390

4,005
4,527
5,129
5,808
6,563
7,394
8,301
9,286
10,351
11,496

LEGEND
Bhp
Brake Horsepower Input to Fan
Watts Input Watts to Motor

*Motor drive ranges:


Low Range: 687-873
Mid-Low Range: 805-1007
Mid-High Range: 941-1176
High Range: 1014-1297
All other rpms require field-supplied drive.

Available External Static Pressure (in. wg)


1.6
Bhp
Rpm
Watts
Bhp
Rpm

4.61
5.21
5.90
6.68
7.55
8.50
9.55
10.68
11.90
13.22

1045
1075
1110
1148
1189
1232
1276
1321
1367

4,334
4,836
5,424
6,096
6,849
7,681
8,591
9,582
10,655

4.98
5.56
6.24
7.01
7.88
8.83
9.88
11.02
12.25

1090
1115
1145
1180
1219
1260
1302
1346
1391

NOTES:
1. Maximum continuous bhp is:
Low Range: 5.75
Mid-Low Range: 5.75
Mid-High Range: 8.63
High Range: 11.50
2. See page 187 for general fan performance notes.

50HJ
205

Performance data 50HJ (cont)


EVAPORATOR-FAN MOTOR PERFORMANCE 50HJ004-014 STANDARD MOTOR
UNIT
50HJ

UNIT
PHASE
Single

MAXIMUM
CONTINUOUS BHP*
1.20

MAXIMUM
OPERATING WATTS*
1000

Three

1.20

1000

Single

1.20

1000

Three

1.20

1000

Single

1.30

1650

Three

2.40

2120

007

Three

2.40

2120

008,009

Three

2.90

2615

012

Three

3.70

3775

014

Three

5.25

4400

004

005

006

UNIT VOLTAGE
208/230
208/230
460
575
208/230
208/230
460
575
208/230
208/230
460
575
208/230
460
575
208/230
460
575
208/230
460
575
208/230
460
575

MAXIMUM
AMP DRAW
4.9
4.9
2.2
2.2
4.9
4.9
2.2
2.2
10.1
6.7
3.0
3.0
6.7
3.0
3.0
8.6
3.9
3.9
12.2
5.5
5.5
17.3
8.5
8.5

LEGEND
Bhp Brake Horsepower
*Extensive motor and electrical testing on these units ensures that the full horsepower and watts range of the
motors can be utilized with confidence. Using your fan motors up to the ratings shown in this table will not
result in nuisance tripping or premature motor failure. Unit warranty will not be affected.

50HJ

EVAPORATOR-FAN MOTOR PERFORMANCE 50HJ004-014 HIGH-STATIC MOTORS


UNIT
50HJ

UNIT
PHASE

MAXIMUM
CONTINUOUS BHP*

MAXIMUM
OPERATING WATTS*

004

Three

2.40

2120

005

Three

2.40

2120

006

Three

2.90

2615

007

Three

2.90

2615

008,009

Three

4.20

3775

012

Three

5.25

4400

LEGEND
Bhp Brake Horsepower
*Extensive motor and electrical testing on these units ensures that the full
horsepower and watts range of the motors can be utilized with confidence.
Using your fan motors up to the ratings shown in this table will not result in
nuisance tripping or premature motor failure. Unit warranty will not be
affected.

206

UNIT VOLTAGE
208/230
460
575
208/230
460
575
208/230
460
575
208/230
460
575
208/230
460
575
208/230
460
575

MAXIMUM
AMP DRAW
6.7
3.0
3.0
6.7
3.0
3.0
8.6
3.9
3.9
8.6
3.9
3.9
12.2
5.5
5.5
17.3
8.5
8.5

EVAPORATOR FAN MOTOR PERFORMANCE 50HJ015,017


UNIT 50HJ
015
(Standard
Motor)
015
(Optional
Motor)
017

NOMINAL HP
2.9
2.9
2.9
3
3.7
3.7
3.7
5
5
5
5

VOLTAGE
208
230
460
575
208
230
460
208
230
460
575

MAX WATTS
2700
2700
2700
3065
3610
3610
3610
5180
5180
5180
5180

EFF. %
85.8
85.8
85.8
81.7
85.8
85.8
85.8
87.5
87.5
87.5
87.5

MAX BHP
3.13
3.13
3.13
3.38
4.26
4.26
4.26
6.13
6.13
6.13
6.13

MAX BkW
2.34
2.34
2.34
2.53
3.27
3.27
3.27
4.57
4.57
4.57
4.57

MAX AMPS
9.46
8.6
4.3
3.9
10.5
10.5
4.8
15.8
15.8
7.9
6.0

LEGEND
BHP Brake Horsepower
BkW Brake Kilowatts

EVAPORATOR-FAN MOTOR EFFICIENCY


50HJ004-014
MOTOR 50HJ
004,005
006
007
008,009
012
014

EFFICIENCY
75
74/84*
84
80
85
87

*Single-phase/3-phase.
NOTES:
1. Convert watts to bhp using the following formula:
bhp =

EVAPORATOR-FAN MOTOR EFFICIENCY


50HJ015,017
MOTOR
HORSEPOWER
3.0
2.9, 3.7
5.0

MOTOR EFFICIENCY
(%)
81.7
85.8
87.5

NOTE: All indoor-fan motors 5 hp and larger meet the minimum efficiency requirements as established by the Energy Policy Act of 1992
(EPACT) effective October 24, 1997.

watts input x motor efficiency


746

2. The EPACT (Energy Policy Act of 1992) regulates energy requirements for specific types of indoor fan motors. Motors regulated by
EPACT include any general purpose, T-frame (three-digit, 143 and
larger), single-speed, foot mounted, polyphase, squirrel cage induction motors of NEMA (National Electrical Manufacturers Association)
design A and B, manufactured for use in the United States. Ranging
from 1 to 200 Hp, these continuous-duty motors operate on 230 and
460 volt, 60 Hz power. If a motor does not fit into these specifications, the motor does not have to be replaced by an EPACTcompliant energy-efficient motor. Variable-speed motors are exempt
from EPACT compliance requirements. Therefore, the indoor fan
motors for Carrier 50HJ004-014 units are exempt from these
requirements.

FAN PERFORMANCE USING ACCESSORY POWER


EXHAUST (50HJ015,017)

50HJ
207

Performance data 50HJ (cont)


50HJ EVAPORATOR FAN MOTOR PERFORMANCE 50HJ020-028
UNIT

DRIVE

ORIENTATION

Low

Vertical

Mid-Low

Vertical

Mid-High

Vertical

High

Vertical

Low

Horizontal

Mid-Low

Horizontal

Mid-High

Horizontal

High

Horizontal

Low

Vertical

Mid-Low

Vertical

Mid-High

Vertical

High

Vertical

Low

Horizontal

Mid-Low

Horizontal

Mid-High

Horizontal

High

Horizontal

50HJ020

50HJ

50HJ024

LEGEND
BHP Brake Horsepower
BkW Brake Kilowatts

208

MOTOR
P/N
N/A
N/A
N/A
N/A
HD60FK651
HD60FK651
HD60FK651
HD58DL575
HD60FL650
HD60FL650
HD60FL650
HD60FL575
HD62FL650
HD62FL650
HD62FL650
HD62FL575
N/A
N/A
N/A
N/A
HD60FK651
HD60FK651
HD60FK651
HD58DL575
HD60FL650
HD60FL650
HD60FL650
HD60FL575
HD62FL650
HD62FL650
HD62FL650
HD62FL575
HD60FK651
HD60FK651
HD60FK651
HD60FL575
HD60FL650
HD60FL650
HD60FL650
HD60FL575
HD62FL650
HD62FL650
HD62FL650
HD62FL575
HD64FL650
HD64FL650
HD64FL650
HD64FL575
HD60FK651
HD60FK650
HD60FK651
HD60FL575
HD60FL650
HD60FL650
HD60FL650
HD60FL575
HD62FL650
HD62FL650
HD62FL650
HD62FL575
HD64FL650
HD64FL650
HD64FL650
HD64FL575

NOMINAL
HP
N/A
N/A
N/A
N/A
3.7
3.7
3.7
3.0
5
5
5
5
7.5
7.5
7.5
7.5
N/A
N/A
N/A
N/A
3.7
3.7
3.7
3
5
5
5
5
7.5
7.5
7.5
7.5
3.7
3.7
3.7
5
5
5
5
5
7.5
7.5
7.5
7.5
10
10
10
10
3.7
3.7
3.7
5
5
5
5
5
7.5
7.5
7.5
7.5
10
10
10
10

VOLTAGE
208
230
460
575
208
230
460
575
208
230
460
575
208
230
460
575
208
230
460
575
208
230
460
575
208
230
460
575
208
230
460
575
208
230
460
575
208
230
460
575
208
230
460
575
208
230
460
575
208
230
460
575
208
230
460
575
208
230
460
575
208
230
460
575

MAX
WATTS
N/A
N/A
N/A
N/A
3698
3698
3698
3149
4900
4900
4900
4900
7267
7267
7267
7267
N/A
N/A
N/A
N/A
3698
3698
3698
3149
4900
4900
4900
4900
7267
7267
7267
7267
3698
3698
3698
4900
4900
4900
4900
4900
7267
7267
7267
7267
9582
9582
9582
9582
3698
3698
3698
4900
4900
4900
4900
4900
7267
7267
7267
7267
9582
9582
9582
9582

EFFICIENCY
%
N/A
N/A
N/A
N/A
85.8
85.8
85.8
81.7
87.5
87.5
87.5
87.5
88.5
88.5
88.5
88.5
N/A
N/A
N/A
N/A
85.8
85.8
85.8
81.7
87.5
87.5
87.5
87.5
88.5
88.5
88.5
88.5
85.8
85.8
85.8
87.5
87.5
87.5
87.5
87.5
88.5
88.5
88.5
88.5
89.5
89.5
89.5
89.5
85.8
85.8
85.8
87.5
87.5
87.5
87.5
87.5
88.5
88.5
88.5
88.5
89.5
89.5
89.5
89.5

MAX
BHP
N/A
N/A
N/A
N/A
4.25
4.25
4.25
3.45
5.75
5.75
5.75
5.75
8.63
8.63
8.63
8.63
N/A
N/A
N/A
N/A
4.25
4.25
4.25
3.45
5.75
5.75
5.75
5.75
8.63
8.63
8.63
8.63
4.25
4.25
4.25
5.75
5.75
5.75
5.75
5.75
8.63
8.63
8.63
8.63
11.5
11.5
11.5
11.5
4.25
4.25
4.25
5.75
5.75
5.75
5.75
5.75
8.63
8.63
8.63
8.63
11.5
11.5
11.5
11.5

MAX
BkW
N/A
N/A
N/A
N/A
3.17
3.17
3.17
2.57
4.29
4.29
4.29
4.29
6.43
6.43
6.43
6.43
N/A
N/A
N/A
N/A
3.17
3.17
3.17
2.57
4.29
4.29
4.29
4.29
6.43
6.43
6.43
6.43
3.17
3.17
3.17
4.29
4.29
4.29
4.29
4.29
6.43
6.43
6.43
6.43
8.58
8.58
8.58
8.58
3.17
3.17
3.17
4.29
4.29
4.29
4.29
4.29
6.43
6.43
6.43
6.43
8.58
8.58
8.58
8.58

MAX
AMPS
N/A
N/A
N/A
N/A
10.6
9.6
4.8
3.9
16.7
15.2
7.6
6.1
24.2
22
11
9
N/A
N/A
N/A
N/A
10.6
9.6
4.8
3.9
16.7
15.2
7.6
6.1
24.2
22
11
9
10.6
9.6
4.8
6.1
16.7
15.2
7.6
6.1
24.2
22
11
9
30.8
28
14
11
10.6
9.6
4.8
6.1
16.7
15.2
7.6
6.1
24.2
22
11
9
30.8
28
14
11

50HJ EVAPORATOR FAN MOTOR PERFORMANCE 50HJ020-028 (cont)


UNIT

DRIVE

ORIENTATION

Low

Vertical

Mid-Low

Vertical

Mid-High

Vertical

High

Vertical

Low

Horizontal

Mid-Low

Horizontal

Mid-High

Horizontal

High

Horizontal

50HJ028

MOTOR
P/N
HD60FL650
HD60FL650
HD60FL650
HD60FL575
HD60FL650
HD60FL650
HD60FL650
HD60FL575
HD62FL650
HD62FL650
HD62FL650
HD62FL575
HD64FL650
HD64FL650
HD64FL650
HD64FL575
HD60FL650
HD60FL650
HD60FL650
HD60FL575
HD60FL650
HD60FL650
HD60FL650
HD60FL575
HD62FL650
HD62FL650
HD62FL650
HD62FL575
HD64FL650
HD64FL650
HD64FL650
HD64FL575

NOMINAL
HP
5
5
5
5
5
5
5
5
7.5
7.5
7.5
7.5
10
10
10
10
5
5
5
5
5
5
5
5
7.5
7.5
7.5
7.5
10
10
10
10

VOLTAGE
208
230
460
575
208
230
460
575
208
230
460
575
208
230
460
575
208
230
460
575
208
230
460
575
208
230
460
575
208
230
460
575

MAX
WATTS
4900
4900
4900
4900
4900
4900
4900
4900
7267
7267
7267
7267
9582
9582
9582
9582
4900
4900
4900
4900
4900
4900
4900
4900
7267
7267
7267
7267
9582
9582
9582
9582

EFFICIENCY
%
87.5
87.5
87.5
87.5
87.5
87.5
87.5
87.5
88.5
88.5
88.5
88.5
89.5
89.5
89.5
89.5
87.5
87.5
87.5
87.5
87.5
87.5
87.5
87.5
88.5
88.5
88.5
88.5
89.5
89.5
89.5
89.5

MAX
BHP
5.75
5.75
5.75
5.75
5.75
5.75
5.75
5.75
8.63
8.63
8.63
8.63
11.5
11.5
11.5
11.5
5.75
5.75
5.75
5.75
5.75
5.75
5.75
5.75
8.63
8.63
8.63
8.63
11.5
11.5
11.5
11.5

MAX
BkW
4.29
4.29
4.29
4.29
4.29
4.29
4.29
4.29
6.43
6.43
6.43
6.43
8.58
8.58
8.58
8.58
4.29
4.29
4.29
4.29
4.29
4.29
4.29
4.29
6.43
6.43
6.43
6.43
8.58
8.58
8.58
8.58

MAX
AMPS
16.7
15.2
7.6
6.1
16.7
15.2
7.6
6.1
24.2
22
11
9
30.8
28
14
11
16.7
15.2
7.6
6.1
16.7
15.2
7.6
6.1
24.2
22
11
9
30.8
28
14
11

51/2

1070

962

1035

830

LEGEND
BHP Brake Horsepower
BkW Brake Kilowatts

FAN RPM AT MOTOR PULLEY SETTING WITH STANDARD MOTOR* 50HJ004-014


UNIT 50HJ
004
005
006
007
008,009
012
014

0
1044
1185
1460
1585
1085
1080
1130

1/
2

1008
1144
1425
1538
1060
1060
1112

1
971
1102
1389
1492
1035
1035
1087

11/2
935
1061
1354
1445
1010
1015
1062

2
898
1019
1318
1399
985
990
1037

MOTOR PULLEY TURNS OPEN


21/2
3
31 / 2
4
862
826
789
753
978
936
895
853
1283
1248
1212
1177
1352
1305
1259
1212
960
935
910
890
970
950
925
905
1212
987
962
937

41 / 2
716
812
1141
1166
865
880
912

5
680
770
1106
1119
840
860
887

*Approximate fan rpm shown (standard motor/drive).

50HJ
209

Performance data 50HJ (cont)


FAN RPM AT MOTOR PULLEY SETTING WITH HIGH-STATIC MOTOR* 50HJ004-014
UNIT 50HJ
004
005
006
007
008
009
012

0
1455
1455
1685
1685
1080
1080
1130

1/2

11/2
1360
1360
1525
1525
988
988
1062

1
1392
1392
1557
1557
1007
1007
1087

1423
1423
1589
1589
1025
1025
1112

MOTOR PULLEY TURNS OPEN


21/2
3
31/2
1297
1265
1233
1297
1265
1233
1460
1428
1396
1460
1428
1396
952
933
915
952
933
915
1212
987
962

2
1328
1328
1493
1493
970
970
1037

4
1202
1202
1364
1364
897
897
937

41/2
1170
1170
1332
1332
878
878
912

5
1138
1138
1300
1300
860
860
887

51/2
1107
1107

962

6
1075
1075

830

51/2
895
1063
895
891
1047

1040

873
1025

*Approximate fan rpm shown (high-static motor/drive).

FAN RPM AND MOTOR PULLEY SETTINGS* 50HJ015,017


UNIT 50HJ

0
1147
1315
1147

015 (208/230, 460 v)


015 (208/230, 460 v)**
015 (575 v)
017
017**

1/
2

1124
1292
1124

11/2
1078
1246
1078

1
1101
1269
1101

2
1055
1223
1055
1021
1200

MOTOR PULLEY TURNS OPEN


21/2
3
31/2
4
1032
1010
987
964
1200
1178
1155
1132
1032
1010
987
964
1002
984
965
947
1178
1156
1134
1112

41/2
941
1109
941
928
1091

5
918
1086
918
910
1069

*Approximate fan rpm shown (belt slip may vary).


Indicates standard drive package.
**Indicates alternate drive package.
Due to belt and pulley style, pulley cannot be set to this number of turns open.

FAN RPM AND MOTOR PULLEY SETTINGS* 50HJ020-028


50HJ

020
(230 and 460 volt)

020
(575 volt)

024
(230 and 460 volt)

50HJ

024
(575 volt)

028
(all voltages)

RANGE
Low Range Vertical
Mid-Low Range Vertical
Mid-High Range Vertical
High Range Vertical
Low Range Horizontal
Mid-Low Range Horizontal
Mid-High Range Horizontal
High Range Horizontal
Low Range Vertical
Mid-Low Range Vertical
Mid-High Range Vertical
High Range Vertical
Low Range Horizontal
Mid-Low Range Horizontal
Mid-High Range Horizontal
High Range Horizontal
Low Range Vertical
Mid-Low Range Vertical
Mid-High Range Vertical
High Range Vertical
Low Range Horizontal
Mid-Low Range Horizontal
Mid-High Range Horizontal
High Range Horizontal
Low Range Vertical
Mid-Low Range Vertical
Mid-High Range Vertical
High Range Vertical
Low Range Horizontal
Mid-Low Range Horizontal
Mid-High Range Horizontal
High Range Horizontal
Low Range Vertical
Mid-Low Range Vertical
Mid-High Range Vertical
High Range Vertical
Low Range Horizontal
Mid-Low Range Horizontal
Mid-High Range Horizontal
High Range Horizontal

*Approximate fan rpm shown.

210

1/
2

11/2

MOTOR PULLEY TURNS OPEN


2
21/2
3
31/2
4

41/2

51/2

647
897
1078

647
897
1078

810
873
1078

810
873
1078
685
949
941
1014
685
949
941
1014
751
949
941
1014
751
949
941
1014
687
805
941
1014
687
805
941
1014

667
917
1094

667
917
1094

832
893
1094

832
893
1094
706
970
961
1038
706
970
961
1038
768
970
961
1038
768
970
961
1038
703
822
961
1038
703
822
961
1038

687
937
1111

687
937
1111

854
912
1111

854
912
1111
727
992
980
1061
727
992
980
1061
785
992
980
1061
785
992
980
1061
718
839
980
1061
718
839
980
1061

707
958
1127

707
958
1127

876
932
1127

876
932
1127
749
1013
1000
1085
749
1013
1000
1085
802
1013
1000
1085
802
1013
1000
1085
734
856
1000
1085
734
856
1000
1085

727
978
1143

727
978
1143

897
951
1143

897
951
1143
770
1035
1019
1108
770
1035
1019
1108
819
1035
1019
1108
819
1035
1019
1108
749
872
1019
1108
749
872
1019
1108

826
1079
1225

826
1079
1225

1007
1049
1225

1007
1049
1225
876
1142
1117
1226
876
1142
1117
1226
903
1142
1117
1226
903
1142
1117
1226
827
957
1117
1226
827
957
1117
1226

846
1099
1241

846
1099
1241

1028
1069
1241

1028
1069
1241
897
1163
1137
1250
897
1163
1137
1250
920
1163
1137
1250
920
1163
1137
1250
842
973
1137
1250
842
973
1137
1250

866
1119
1258

866
1119
1258

1050
1088
1258

1050
1088
1258
918
1185
1156
1273
918
1185
1156
1273
937
1185
1156
1273
937
1185
1156
1273
858
990
1156
1273
858
990
1156
1273

886
1139
1274

886
1139
1274

1072
1108
1274

1072
1108
1274
939
1206
1176
1297
939
1206
1176
1297
954
1206
1176
1297
954
1206
1176
1297
873
1007
1176
1297
873
1007
1176
1297

747
998
1160

747
998
1160

919
971
1160

919
971
1160
791
1056
1039
1132
791
1056
1039
1132
836
1056
1039
1132
836
1056
1039
1132
765
889
1039
1132
765
889
1039
1132

767
1018
1176

767
1018
1176

941
991
1176

941
991
1176
812
1078
1059
1156
812
1078
1059
1156
853
1078
1059
1156
853
1078
1059
1156
780
906
1059
1156
780
906
1059
1156

786
1038
1192

786
1038
1192

963
1010
1192

963
1010
1192
833
1099
1078
1179
833
1099
1078
1179
869
1099
1078
1179
869
1099
1078
1179
796
923
1078
1179
796
923
1078
1179

806
1058
1209

806
1058
1209

985
1030
1209

985
1030
1209
854
1120
1098
1203
854
1120
1098
1203
886
1120
1098
1203
886
1120
1098
1203
811
940
1098
1203
811
940
1098
1203

ACCESSORY/FIOP ECONOMI$ER IV AND ECONOMI$ER2 STATIC PRESSURE* (in. wg) 50HJ004-007


CFM

COMPONENT
Vertical EconoMi$er IV and EconoMi$er2
Horizontal EconoMi$er IV and EconoMi$er2

1250
0.045

1500
0.065

LEGEND
FIOP Factory-Installed Option

1750
0.08
0.1

2000
0.12
0.125

2250
0.145
0.15

2500
0.175
0.18

2750
0.22
0.225

3000
0.255
0.275

*The static pressure must be added to external static pressure. The


sum and the evaporator entering-air cfm should be used in conjunction
with the Fan Performance tables to determine indoor blower rpm and
watts.

ACCESSORY/FIOP ECONOMI$ER IV AND ECONOMI$ER2 STATIC PRESSURE* (in. wg) 50HJ008-014


CFM
2250 2500 2750 3000 3250 3500 3750 4000 4250 4500 4750 5000 5250 6250
Vertical EconoMi$er IV and EconoMi$er2
0.06 0.075 0.09 0.115 0.13 0.15 0.17 0.195 0.22 0.25 0.285 0.325 0.36

Horizontal EconoMi$er IV and EconoMi$er2


0.1 0.125 0.15 0.18 0.21 0.25 0.275 0.3
0.34 0.388

COMPONENT

LEGEND
FIOP Factory-Installed Option

*The static pressure must be added to external static pressure. The


sum and the evaporator entering-air cfm should be used in conjunction
with the Fan Performance tables to determine indoor blower rpm and
watts.

HORIZONTAL ECONOMI$ER IV AND


ECONOMI$ER2 PERFORMANCE DATA (50HJ004-

VERTICAL ECONOMI$ER IV AND ECONOMI$ER2


PERFORMANCE DATA (50HJ004-014)
5000

2500
2000

3000

3-6 Ton

2000

7.5-12.5 Ton

FLOW (cfm)

FLOW (cfm)

4000

1000

1500
1000
500

0
0

0.1

0.2

0.3

0.4

0.5
0

STATIC PRESSURE (in. wg)

VERTICAL POWER EXHAUST PERFORMANCE

0.1

0.2

0.3

0.4

0.5

STATIC PRESSURE (in. wg)

2500

2500
2000
3-6 Ton

1500

7 1/2 - 12 1/2 Ton


1000
500
0
0.15

0.05

Flow in cubic feet per minute (cfm)

FLOW IN CUBIC FEET PER MINUTE (cfm)

HORIZONTAL POWER EXHAUST PERFORMANCE

2000

1500
3-6 Ton
7-12 1/2 Ton
1000

500

0.25

STATIC PRESSURE (in. wg)

0.05"

0.15"

BAROMETRIC RELIEF FLOW CAPACITY

0.25"

Static Pressure (in. wg)

25
20
3-6 Ton
7 1/2-12 1/2 Ton

15
10
5
0
0.13

0.20 0.22

0.25

0.30 0.35 0.40

0.45

0.50

STATIC PRESSURE (in. wg)

OUTDOOR AIR DAMPER LEAKAGE

Flow in cubic feet per minute (cfm)

30

50HJ

FLOW IN CUBIC FEET PER MINUTE (cfm)

BAROMETRIC RELIEF CAPACITY

30
25
20
3-6 Ton

15

7-12 1/2 Ton

10
5
0
0.1"

0.2"

0.3"

0.4"

0.5"

Static Pressure (in. wg)

OUTDOOR AIR DAMPER LEAKAGE

211

Performance data 50HJ (cont)


ACCESSORY/FIOP STATIC PRESSURE (in. wg)* 50HJ020-028
COMPONENT

4,000
0.02
0.00

Economizer
4-in. Filters

4,500
0.03
0.02

5,000
0.04
0.003

5,500
0.05
0.05

CFM
6,000
0.06
0.06

6,500
0.07
0.08

7,000
0.08
0.09

7,500
0.09
0.11

CFM

COMPONENT

8,500
0.02
0.00

Economizer
4-in. Filters

9,000
0.03
0.02

9,500
0.04
0.003

10,000
0.05
0.05

10,500
0.06
0.06

11,000
0.07
0.08

11,500
0.08
0.09

LEGEND
FIOP Factory-Installed Option
*The static pressure must be added to external static pressure. The sum and the evaporator entering-air cfm should
then be used in conjunction with the Fan Performance tables to determine blower rpm and watts.
Four-inch filters are field-supplied.

HUMIDI-MIZER ADAPTIVE DEHUMIDIFICATION COIL PRESSURE DROP


0.35

Coil Pressure Drop (in. wg)

0.3

0.25

0.2

0.15

0.1

0.05

0
0

1000

50HJ

3 ton

212

8,000
0.10
0.12

2000
4 & 5 ton

3000
Airflow (CFM)
6 ton

4000
7.5 ton

5000
8.5, 10 & 12.5 ton

6000

12,000
0.09
0.11

ACCESSORY/FIOP STATIC PRESSURE (in. wg)* 50HJ015,017


COMPONENT
EconoMi$er IV and EconoMi$er2
MoistureMi$er Dehumidification Package

4500
0.040
0.045

5000
0.050
0.048

LEGEND
FIOP Factory-Installed Option

1 Heater
Module
2 Heater
Modules

6000
0.070
0.071

CFM
7200
0.090
0.103

7500
0.100
0.111

9000
0.110
0.160

10,000
0.120
0.197

11,250
0.140
0.250

*The static pressure must be added to external static pressure. The


sum and the evaporator entering-air cfm should then be used in
conjunction with the Fan Performance tables to determine blower rpm
and watts.

ACCESSORY ELECTRIC HEATERS STATIC PRESSURE


DROP (in. wg) 50HJ004-007
COMPONENT

5400
0.060
0.060

CFM
900 1200 1400 1600 1800 2000 2200 2400 2600
0.05 0.07 0.09 0.09 0.10 0.11 0.11 0.12 0.13
0.15 0.16 0.16 0.16 0.17 0.17 0.17 0.18 0.18

ACCESSORY ELECTRIC HEATERS STATIC PRESSURE


DROP (in. wg) 50HJ008-014
COMPONENT
1 Heater
Module
2 Heater
Modules

CFM
2200 2500 3000 3500 4000 4500 5000 5500 6000
0.02 0.03 0.05 0.065 0.08 0.10 0.12 0.14 0.155
0.03 0.05 0.07 0.09

0.12 0.14 0.16 0.19 0.21

ACCESSORY ELECTRIC HEATER STATIC PRESSURE (in. wg) 50HJ015,017 UNITS


UNIT 50HJ

HEATER RATED VOLTAGE*

208/240-3-60

015, 017

480-3-60

600-3-60

LEGEND
FIOP Factory-Installed Option
*There are no electric heaters available for 017 575-v units.

CFM
3,750
4,000
5,000
6,000
7,200
7,500
3,750
4,000
5,000
6,000
7,200
7,500
3,750
4,000
5,000
6,000
7,200
7,500

ELECTRIC HEATERS PRESSURE DROP (kW)


0.05 (14/19, 26/34)
0.06 (42/56)
0.07 (56/75)
0.05 (14/19, 26/34)
0.06 (42/56)
0.07 (56/75)
0.07 (14/19, 26/34)
0.08 (42/56)
0.10 (56/75)
0.09 (14/19, 26/34)
0.12 (42/56)
0.15 (56/75)
0.11 (14/19, 26/34)
0.16 (42/56)
0.20 (56/75)
0.12 (14/19, 26/34)
0.17 (42/56)
0.21 (56/75)
0.05 (15, 32)
0.06 (55)
0.07 (80)
0.05 (15, 32)
0.06 (55)
0.07 (80)
0.07 (15, 32)
0.08 (55)
0.10 (80)
0.09 (15, 32)
0.12 (55)
0.15 (80)
0.11 (15, 32)
0.15 (55)
0.20 (80)
0.12 (15, 32)
0.17 (55)
0.21 (80)
0.06 (40)
0.06 (40)
0.08 (40)
0.12 (40)
0.15 (40)
0.17 (40)
NOTES:
1. Heaters are rated at 240 v, 480 v, and 600 v.
2. The factory assembled horizontal adapter substantially improves
fan performance.
3. The static pressure must be added to external static pressure. The
sum and the evaporator entering-air cfm should then be used in
conjunction with the Fan Performance table to determine blower
rpm, bhp, and watts.

50HJ
213

Performance data 50HJ (cont)


ACCESSORY ELECTRIC HEAT STATIC PRESSURE (in. wg) 50HJ020-028 UNITS
ELECTRIC HEATERS
UNIT
50HJ

Unit
Voltages
208/240

208/240-3-60

020,
024,028

480-3-60

575-3-60

Cfm
4,800
5,000
6,000
7,000
8,000
9,000
10,000
11,500
4,800
5,000
6,000
7,000
8,000
9,000
10,000
11,500
4,800
5,000
6,000
7,000
8,000
9,000
10,000
11,500

Nominal
Heater Size
(kW)

Pressure Drop
(in. wg)

25

0.01
0.01
0.02
0.03
0.04
0.05
0.06
0.09
0.01
0.01
0.02
0.03
0.04
0.05
0.06
0.09
0.01
0.01
0.02
0.03
0.04
0.05
0.06
0.09

LEGEND
FIOP Factory-Installed Option
NOTES:
1. Heaters are rated at 240 v, 480 v, and 600 v.

Nominal
Heater Size
(kW)

Pressure Drop
(in. wg)

50

0.02
0.02
0.04
0.06
0.08
0.10
0.13
0.18
0.02
0.02
0.04
0.06
0.08
0.10
0.13
0.18
0.02
0.02
0.04
0.06
0.08
0.10
0.13
0.18

Nominal
Heater Size
(kW)

Pressure Drop
(in. wg)

75

0.03
0.04
0.06
0.08
0.12
0.15
0.20
0.27
0.03
0.04
0.06
0.08
0.12
0.15
0.20
0.27
0.03
0.04
0.06
0.08
0.12
0.15
0.20
0.27

2. The static pressure must be added to external static pressure. The


sum and the evaporator entering-air cfm should then be used in
conjunction with the Fan Performance table to determine blower
rpm, bhp, and watts.

ELECTRIC RESISTANCE HEATER DATA 50HJ015-028


HEATER kW
MINIMUM
HEAT MAXIMUM
HEATER %PER
Unit Voltages
Heating Cfm
STAGES STAGE STAGES*
208 230 240 460 480 575 600
Cfm
L/s
14 17 19 14 15

1
100
1
015
26 31 34 30 32

2
50/50
2
3750 1770
42 52 56 50 55 37 40
2
33/67
3
26 31 34 30 32

2
50/50
2
42 52 56 50 55

2
33/67
3
3750 1770
017
56 69 75 73 80

2
50/50
4
19 23 25 23 25 23 25
2
50/50
2
020,
38 46 50 46 50 44 48
2
50/50
2
4800 2265
024,028
56 69 75 69 75 72 78
2
50/50
2

50HJ

UNIT
50HJ

HEATER AMPS
208
39.3
71.3
117.0
71.3
117.0
155.9
52.0
104.0
156.0

230
43.4
78.9
129.4
78.8
129.4
172.4
58.0
115.0
173.0

240
45.3
82.3
135.0
82.3
135.0
179.9
60.0
120.0
180.0

*Maximum number of stages using accessory low-ambient kit or head pressure control device and low-ambient kit.
NOTE: Heaters are rated at 208, 240, 480, and 600 v. Use multiplication factors table to determine kW at different voltages.

214

460
17.2
37.3
63.3
37.3
63.3
92.0
29.0
58.0
86.0

480
17.9
39.0
66.1
39.0
66.1
96.0
30.0
60.0
90.0

575

37.0

23.0
44.0
72.0

600

38.6

24.0
46.0
75.0

MULTIPLICATION FACTORS
HEATER RATING
VOLTAGE
240
480
600

200
0.69

208
0.75

230
0.92

240
1.000

ACTUAL HEATER VOLTAGE


380
440
460

0.63
0.84
0.92

480

1.00

550

0.84

575

0.92

600

1.00

NOTE: The following equation converts kW of heat energy to Btuh: kW x 3.413 = Btuh.
EXAMPLE: 26.0 kW (at 240 v) heater on 208 v
= 26.0 (.75 mult factor)
= 19.5 kW capacity at 208 v.

COOLING OPERATION AIR QUANTITY LIMITS


50HJ015,017
UNIT 50HJ
015
017

MINIMUM CFM
3600
4500

MINIMUM HEATING AIRFLOW


50HJ004-014

MAXIMUM CFM
6250
7500

UNIT 50HJ
004
005
006
007
008
009
012
014

OUTDOOR AIR LOW TEMPERATURE


OPERATING LIMITS 50HJ015,017
UNIT
SIZE
50HJ
015, 017

Standard
Unit
40

TEMPERATURE LIMIT (F)


Unit With
Unit With
Low Ambient Kit Motormaster I Control
20
20

CFM
900
1200
1500
1800
2250
2550
3000
3750

OUTDOOR SOUND POWER (TOTAL UNIT)


UNIT
50HJ
004,005
006,007
008,009
012
014
015,017
020-024
028

ARI
RATING
(decibels)
76
80
82
84
86
88
82
85

OCTAVE BANDS

A-WEIGHT
(dB)

63

125

250

500

1000

2000

4000

8000

76.0
80.0
82.0
84.0
86.0
87.6
81.7
84.9

55.9
59.1
62.2
64.6
63.7
90.8
90.2
90.0

66.0
68.9
69.3
71.1
69.9
88.7
84.8
86.3

64.0
68.7
71.5
73.3
72.5
86.4
80.7
83.6

66.2
71.9
74.7
76.9
78.2
84.3
79.0
82.9

68.4
74.0
76.2
77.6
81.1
83.5
77.6
80.3

64.5
68.9
72.9
73.7
77.3
78.4
71.4
74.9

61.7
65.7
68.7
70.6
73.3
75.6
66.7
71.4

57.3
59.0
61.5
63.7
66.8
66.8
60.7
66.5

LEGEND
ARI Air Conditioning and Refrigeration Institute
NOTE: Indoor sound power is available in Carriers Electronic Catalog Program (ECAT) for
specific operating parameters.

50HJ
215

Performance data 50HJ (cont)


ELECTRIC HEATER USAGE 50HJ004-007
UNIT SIZE
50HJ

VOLTAGE
V-PH-60 Hz
208/230/240-1

004

208/230/240-3

460/480-3

208/230/240-1

005

208/230/240-3

460/480-3

208/230/240-1

006

208/230/240-3

kW AT EACH
VOLTAGE
3.3/ 4.0/ 4.4
4.9/ 5.8/ 6.5
6.5/ 8.0/ 8.7
7.9/ 9.6/10.5
9.8/11.6/13.0
3.3/ 4.0/ 4.4
4.9/ 5.8/ 6.5
6.5/ 8.0/ 8.7
7.9/ 9.6/10.5
12.0/14.7/16.0
5.5/ 6.0
8.1/ 8.8
10.6/11.5
12.9/14.0
3.3/ 4.0/ 4.4
6.5/ 8.0/ 8.7
9.8/11.6/13.0
13.1/16.0/17.4
16.0/19.3/21.0
4.9/ 5.8/ 6.5
6.5/ 8.0/ 8.7
12.0/14.7/16.0
16.0/19.3/21.0
5.5/ 6.0
10.6/11.5
12.9/14.0
21.1/23.0
4.9/ 5.8/ 6.5
6.5/ 8.0/ 8.7
8.7/11.6/13.0
13.0/16.0/17.4
15.8/19.3/21.0
4.9/ 5.8/ 6.5
7.9/ 9.6/10.5
12.0/14.7/16.0
15.8/19.3/21.0
19.9/24.3/26.5

460/480-3

5.5/ 6.0
10.6/11.5
12.9/14.0
21.1/23.0
23.4/25.5

208/230/240-3

4.9/ 5.8/ 6.5


7.9/ 9.6/10.5
12.0/14.7/16.0
15.8/19.3/21.0
19.9/24.3/26.5

007
460/480-3

5.5/ 6.0
10.6/11.5
12.9/14.0
21.1/23.0

50HJ

23.4/25.5

FIOP
UL

REQUIRED HEATER
PART NUMBER(S)
CRHEATER101A00
CRHEATER102A00
CRHEATER103A00
CRHEATER104A00
(2) CRHEATER102A00
CRHEATER101A00
CRHEATER102A00
CRHEATER103A00
CRHEATER104A00
CRHEATER105A00
CRHEATER106A00
CRHEATER107A00
CRHEATER108A00
CRHEATER109A00
CRHEATER101A00
CRHEATER103A00
(2) CRHEATER102A00
(2) CRHEATER103A00
(2) CRHEATER104A00
CRHEATER102A00
CRHEATER103A00
CRHEATER105A00
(2) CRHEATER104A00
CRHEATER106A00
CRHEATER108A00
CRHEATER109A00
(2) CRHEATER108A00
CRHEATER102A00
CRHEATER103A00
(2) CRHEATER102A00
(2) CRHEATER103A00
(2) CRHEATER104A00
CRHEATER102A00
CRHEATER104A00
CRHEATER105A00
(2) CRHEATER104A00
(1) CRHEATER104A00 and
(1) CRHEATER105A00
CRHEATER106A00
CRHEATER108A00
CRHEATER109A00
(2) CRHEATER108A00
(1) CRHEATER108A00 and
(1) CRHEATER109A00
CRHEATER102A00
CRHEATER104A00
CRHEATER105A00
(2) CRHEATER104A00
(1) CRHEATER104A00 and
(1) CRHEATER105A00
CRHEATER106A00
CRHEATER108A00
CRHEATER109A00
(2) CRHEATER108A00
(1) CRHEATER108A00 and
(1) CRHEATER109A00

LEGEND
Factory-Installed Option
Underwriters Laboratories

*When utilizing 115-volt convenience outlet FIOP with standard motor,


CRSINGLE004A00 must be used.
When utilizing 115-volt convenience outlet FIOP with high-static motor
only, CRSINGLE002A00 must be used.

216

SINGLE-POINT ELECTRIC
HEATER PACKAGES PART NUMBER
Not Required
Not Required
Not Required
Not Required*
CRSINGLE004A00
Not Required
Not Required
Not Required
Not Required
Not Required
Not Required
Not Required
Not Required
Not Required
Not Required
Not Required
CRSINGLE004A00
CRSINGLE004A00
CRSINGLE004A00
Not Required
Not Required
Not Required
CRSINGLE002A00
Not Required
Not Required
Not Required
Not Required
Not Required
Not Required*
CRSINGLE004A00
CRSINGLE004A00
CRSINGLE004A00
Not Required
Not Required
Not Required
CRSINGLE002A00
CRSINGLE002A00
Not Required
Not Required
Not Required
Not Required
Not Required
Not Required
Not Required
Not Required
CRSINGLE002A00
CRSINGLE002A00
Not Required
Not Required
Not Required
Not Required
Not Required

NOTES:
1. For those kWs where two heater packages are furnished, the opportunity exists for two-stage capabilities.
2. Non-fused disconnect switch cannot be used when rooftop electrical
ratings exceed 80 amps.
3. Only those heaters and combinations of heaters shown above are
UL approved.

ELECTRIC HEATER USAGE 50HJ008-014


UNIT SIZE
50HJ

VOLTAGE
V-PH-60 Hz

kW AT EACH
VOLTAGE
7.8/ 9.6/10.4
12.0/14.7/16.0
18.6/22.8/24.8
24.0/29.4/32.0

217

50HJ

REQUIRED HEATER
SINGLE-POINT ELECTRIC
PART NUMBER(S)
HEATER PACKAGES PART NUMBER
CRHEATER117A00
CRSINGLE006A00*
CRHEATER110A00
CRSINGLE006A00*
CRHEATER111A00
CRSINGLE007A00
208/230/240-3
CRHEATER112A00
CRSINGLE007A00
(1) CRHEATER112A00 and
31.8/39.0/42.4
CRSINGLE009A00
(1) CRHEATER117A00
12.8/13.9
CRHEATER116A00
CRSINGLE006A00
008
15.2/16.5
CRHEATER113A00
CRSINGLE006A00
25.6/27.8
CRHEATER114A00
CRSINGLE006A00
460/480-3
30.4/33.0
CRHEATER115A00
CRSINGLE006A00
(1) CRHEATER114A00 and
CRSINGLE008A00
38.4/41.7
(1) CRHEATER116A00
17.0
CRHEATER118A00
CRSINGLE006A00
575-3
34.0
CRHEATER119A00
CRSINGLE006A00
7.8/ 9.6/10.4
CRHEATER117A00
CRSINGLE011A00
12.0/14.7/16.0
CRHEATER110A00
CRSINGLE011A00
18.6/22.8/24.8
CRHEATER111A00
CRSINGLE012A00
208/230/240-3
24.0/29.4/32.0
CRHEATER112A00
CRSINGLE012A00
(1) CRHEATER112A00 and
31.8/39.0/42.4
CRSINGLE015A00
(1) CRHEATER117A00
12.8/13.9
CRHEATER116A00
CRSINGLE011A00
009
15.2/16.5
CRHEATER113A00
CRSINGLE011A00
25.6/27.8
CRHEATER114A00
CRSINGLE011A00
460/480-3
30.4/33.0
CRHEATER115A00
CRSINGLE011A00
(1) CRHEATER114A00 and
38.4/41.7
CRSINGLE014A00
(1) CRHEATER116A00
17.0
CRHEATER118A00
CRSINGLE011A00
575-3
34.0
CRHEATER119A00
CRSINGLE011A00
7.8/ 9.6/10.4
CRHEATER117A00
CRSINGLE011A00
12.0/14.7/16.0
CRHEATER110A00
CRSINGLE012A00
24.0/29.4/32.0
CRHEATER112A00
CRSINGLE012A00
208/230/240-3
(1) CRHEATER112A00 and
31.8/38.9/42.4
CRSINGLE015A00
(1) CRHEATER117A00
(1) CRHEATER112A00 and
37.5/46.0/50.0
CRSINGLE015A00
(1) CRHEATER110A00
12.8/13.9
CRHEATER116A00
CRSINGLE011A00
15.2/16.5
CRHEATER113A00
CRSINGLE011A00
012
30.4/33.0
CRHEATER115A00
CRSINGLE011A00**
460/480-3
(1) CRHEATER114A00 and
38.4/41.7
CRSINGLE014A00
(1) CRHEATER116A00
(1) CRHEATER115A00 and
46.0/50.0
CRSINGLE014A00
(1) CRHEATER113A00
17.0
CRHEATER118A00
CRSINGLE011A00
34.0
CRHEATER119A00
CRSINGLE011A00
575-3
(1) CRHEATER118A00 and
51.0
CRSINGLE014A00
(1) CRHEATER119A00
7.8/ 9.6/10.4
CRHEATER117A00
CRSINGLE012A00
12.0/14.7/16.0
CRHEATER110A00
CRSINGLE012A00
24.0/29.4/32.0
CRHEATER112A00
CRSINGLE012A00
208/230/240-3
(1) CRHEATER112A00 and
31.8/38.9/42.4
CRSINGLE015A00
(1) CRHEATER117A00
(1) CRHEATER112A00 and
37.5/46.0/50.0
CRSINGLE015A00
(1) CRHEATER110A00
12.8/13.9
CRHEATER116A00
CRSINGLE011A00
15.2/16.5
CRHEATER113A00
CRSINGLE011A00
014
30.4/33.0
CRHEATER115A00
CRSINGLE011A00***
460/480-3
(1) CRHEATER114A00 and
38.4/41.7
CRSINGLE014A00
(1) CRHEATER116A00
(1)
CRHEATER115A00
and
46.0/50.0
CRSINGLE014A00
(1) CRHEATER113A00
17.0
CRHEATER118A00
CRSINGLE011A00
34.0
CRHEATER119A00
CRSINGLE014A00
575-3
(1) CRHEATER118A00 and
51.0
CRSINGLE014A00
(1) CRHEATER119A00
LEGEND
When utilizing high-static motor with or without 115-volt convenience outlet FIOP, CRSINGLE014A00 must be used.
FIOP Factory-Installed Option
***When utilizing 115-volt convenience outlet FIOP, CRSINGLE014A00
UL
Underwriters Laboratories
must be used.
*For use with standard motor without convenience outlet only, when
NOTES:
utilizing high-static motor or 115-volt convenience outlet FIOP,
1. For those kWs where two heater packages are furnished, the opporCRSINGLE012A00 must be used.
tunity exists for two-stage capabilities.
For use with standard motor without convenience outlet only, when
2. Non-fused disconnect switch cannot be used when rooftop electrical
utilizing high-static motors or 115-v convenience outlet FIOP,
ratings exceed 80 amps.
CRSINGLE012A00 must be used.
3. Only those heaters and combinations of heaters shown above are
**When utilizing 115-volt convenience outlet FIOP with high-static
UL approved.
motor, CRSINGLE014A00 must be used.
4. CRSINGLE006A00 and CRSINGLE011A00 kits do not require fuses.

Performance data 50HJ (cont)


ELECTRIC HEATER USAGE COBRA ENERGY RECOVERY UNITS 50HJ004-007 AND 62AQ060
50HJ/62AQ
UNIT SIZE

VOLTAGE
V-PH-60 Hz
208/230/240-1

004/060

208/230/240-3

460/480-3

208/230/240-1

005/060

208/230/240-3

460/480-3

208/230/240-1

006/060

208/230/240-3

kW AT EACH
VOLTAGE
3.3/ 4.0/ 4.4
4.9/ 5.8/ 6.5
6.5/ 8.0/ 8.7
7.9/ 9.6/10.5
9.8/11.6/13.0
3.3/ 4.0/ 4.4
4.9/ 5.8/ 6.5
6.5/ 8.0/ 8.7
7.9/ 9.6/10.5
12.0/14.7/16.0
5.5/ 6.0
8.1/ 8.8
10.6/11.5
12.9/14.0
3.3/ 4.0/ 4.4
6.5/ 8.0/ 8.7
9.8/11.6/13.0
13.1/16.0/17.4
16.0/19.3/21.0
4.9/ 5.8/ 6.5
6.5/ 8.0/ 8.7
12.0/14.7/16.0
16.0/19.3/21.0
5.5/ 6.0
10.6/11.5
12.9/14.0
21.1/23.0
4.9/ 5.8/ 6.5
6.5/ 8.0/ 8.7
9.8/11.6/13.0
13.1/16.0/17.4
16.0/19.3/21.0
4.9 /5.8/ 6.5
7.9/ 9.6/10.5
12.0/14.7/16.0
16.0/19.3/21.0
20.0/24.3/26.5

460/480-3

5.5 /6.0
10.6/11.5
12.9/14.0
21.1/23.0
23.4/25.5

208/230/240-3

4.9/ 5.8/ 6.5


7.9/ 9.6/10.5
12.0/14.7/16.0
15.8/19.3/21.0
19.9/24.3/26.5

007/060
460/480-3

5.5 /6.0
10.6/11.5
12.9/14.0
21.1/23.0

50HJ

23.4/25.5

FIOP
UL

REQUIRED HEATER
PART NUMBER(S)
CRHEATER101A00
CRHEATER102A00
CRHEATER103A00
CRHEATER104A00
(2) CRHEATER102A00
CRHEATER101A00
CRHEATER102A00
CRHEATER103A00
CRHEATER104A00
CRHEATER105A00
CRHEATER106A00
CRHEATER107A00
CRHEATER108A00
CRHEATER109A00
CRHEATER101A00
CRHEATER103A00
(2) CRHEATER102A00
(2) CRHEATER103A00
(2) CRHEATER104A00
CRHEATER102A00
CRHEATER103A00
CRHEATER105A00
(2) CRHEATER104A00
CRHEATER106A00
CRHEATER108A00
CRHEATER109A00
(2) CRHEATER108A00
CRHEATER102A00
CRHEATER103A00
(2) CRHEATER102A00
(2) CRHEATER103A00
(2) CRHEATER104A00
CRHEATER102A00
CRHEATER104A00
CRHEATER105A00
(2) CRHEATER104A00
(1) CRHEATER104A00 and
(1) CRHEATER105A00
CRHEATER106A00
CRHEATER108A00
CRHEATER109A00
(2) CRHEATER108A00
(1) CRHEATER108A00 and
(1) CRHEATER109A00
CRHEATER102A00
CRHEATER104A00
CRHEATER105A00
(2) CRHEATER104A00
(1) CRHEATER104A00 and
(1) CRHEATER105A00
CRHEATER106A00
CRHEATER108A00
CRHEATER109A00
(2) CRHEATER108A00
(1) CRHEATER108A00 and
(1) CRHEATER109A00

LEGEND
Factory-Installed Option
Underwriters Laboratories

*When utilizing 115-volt convenience outlet FIOP with high-static


motor, CRSINGLE005A00 must be used.
When utilizing 115-volt convenience outlet FIOP with high-static
motor, CRSINGLE003A00 must be used.
**When utilizing 115-volt convenience outlet FIOP, CRSINGLE025A00
must be used.
For use with standard motor without convenience outlet only, when
utilizing high-static motor or 115-volt convenience outlet FIOP,
CRSINGLE003A00 must be used.

218

SINGLE-POINT ELECTRIC HEATER


PACKAGES PART NUMBER
Not Required
Not Required
CRSINGLE004A00
CRSINGLE004A00*
CRSINGLE005A00
Not Required
Not Required
Not Required
Not Required
CRSINGLE002A00
Not Required
Not Required
Not Required
Not Required**
Not Required
CRSINGLE004A00
CRSINGLE005A00
CRSINGLE005A00
CRSINGLE005A00
Not Required
Not Required
CRSINGLE002A00
CRSINGLE003A00
Not Required
Not Required
Not Required**
CRSINGLE025A00
CRSINGLE004A00
CRSINGLE004A00*
CRSINGLE005A00
CRSINGLE005A00
CRSINGLE005A00
Not Required
Not Required
CRSINGLE002A00
CRSINGLE003A00
CRSINGLE003A00
Not Required
Not Required
Not Required**
CRSINGLE025A00
CRSINGLE025A00
Not Required
Not Required
CRSINGLE002A00
CRSINGLE003A00
CRSINGLE003A00
Not Required
Not Required
Not Required**
CRSINGLE025A00
CRSINGLE025A00

NOTES:
1. For those kWs where two heater packages are furnished, the opportunity exists for two-stage capabilities.
2. Non-fused disconnect switch cannot be used when rooftop electrical
ratings exceed 80 amps.
3. Only those heaters and combinations of heaters shown above are
UL approved.

ELECTRIC HEATER USAGE COBRA ENERGY RECOVERY UNITS 50HJ004-007 AND 62AQ100
50HJ/62AQ
UNIT SIZE

VOLTAGE
V-PH-60 Hz
208/230/240-1

004/100

208/230/240-3

460/480-3

208/230/240-1

005/100

208/230/240-3

460/480-3

208/230/240-1

006/100

208/230/240-3

kW AT EACH
VOLTAGE
3.3/ 4.0/ 4.4
4.9/ 5.8/ 6.5
6.5/ 8.0/ 8.7
7.9/ 9.6/10.5
9.8/11.6/13.0
3.3/ 4.0/ 4.4
4.9/ 5.8/ 6.5
6.5/ 8.0/ 8.7
7.9/ 9.6/10.5
12.0/14.7/16.0
5.5/ 6.0
8.1/ 8.8
10.6/11.5
12.9/14.0
3.3/ 4.0/ 4.4
6.5/ 8.0/ 8.7
9.8/11.6/13.0
13.1/16.0/17.4
16.0/19.3/21.0
4.9/ 5.8/ 6.5
6.5/ 8.0/ 8.7
12.0/14.7/16.0
16.0/19.3/21.0
5.5/ 6.0
10.6/11.5
12.9/14.0
21.1/23.0
4.9/ 5.8/ 6.5
6.5/ 8.0/ 8.7
9.8/11.6/13.0
13.1/16.0/17.4
16.0/19.3/21.0
4.9/ 5.8/ 6.5
7.9/ 9.6/10.5
12.0/14.7/16.0
16.0/19.3/21.0
20.0/24.3/26.5

460/480-3

5.5/ 6.0
10.6/11.5
12.9/14.0
21.1/23.0
23.4/25.5

208/230/240-3

4.9/ 5.8/ 6.5


7.9/ 9.6/10.5
12.0/14.7/16.0
15.8/19.3/21.0
19.9/24.3/26.5

007/100
460/480-3

5.5/ 6.0
10.6/11.5
12.9/14.0
21.1/23.0
23.4/25.5

LEGEND
Factory-Installed Option
Underwriters Laboratories

*When
utilizing
115-volt
convenience
outlet
FIOP,
CRSINGLE005A00 must be used.
When
utilizing
115-volt
convenience
outlet
FIOP,
CRSINGLE002A00 must be used.
**When utilizing 115-volt convenience outlet FIOP with high-static
motor, CRSINGLE003A00 must be used.
When
utilizing
115-volt
convenience
outlet
FIOP,
CRSINGLE004A00 must be used.
***For use with standard motor without convenience outlet only, when
utilizing high-static motor or 115-volt convenience outlet FIOP,
CRSINGLE002A00 must be used.
When
utilizing
115-volt
convenience
outlet
FIOP,
CRSINGLE003A00 must be used.

SINGLE-POINT ELECTRIC HEATER


PACKAGES PART NUMBER
Not Required
CRSINGLE004A00
CRSINGLE004A00
CRSINGLE004A00*
CRSINGLE005A00
Not Required
Not Required
Not Required
Not Required
CRSINGLE002A00**
Not Required
Not Required
CRSINGLE025A00
CRSINGLE025A00
Not Required
CRSINGLE004A00
CRSINGLE005A00
CRSINGLE005A00
CRSINGLE005A00
Not Required
Not Required
CRSINGLE002A00**
CRSINGLE003A00
Not Required
CRSINGLE025A00
CRSINGLE025A00
CRSINGLE025A00
CRSINGLE004A00
CRSINGLE004A00*
CRSINGLE005A00
CRSINGLE005A00
CRSINGLE005A00
Not Required
Not Required*
CRSINGLE002A00
CRSINGLE003A00
CRSINGLE003A00
Not Required
CRSINGLE025A00
CRSINGLE025A00
CRSINGLE025A00
CRSINGLE025A00
Not Required
Not Required***
CRSINGLE002A00
CRSINGLE003A00
CRSINGLE003A00
Not Required
CRSINGLE025A00
CRSINGLE025A00
CRSINGLE025A00
CRSINGLE025A00

For use with standard motor without convenience outlet only, when utilizing high-static motor or 115-volt convenience outlet FIOP,
CRSINGLE003A00 must be used.
NOTES:
1. For those kWs where two heater packages are furnished, the opportunity exists for two-stage capabilities.
2. Non-fused disconnect switch cannot be used when rooftop electrical
ratings exceed 80 amps.
3. Only those heaters and combinations of heaters shown above are
UL approved.

219

50HJ

FIOP
UL

REQUIRED HEATER
PART NUMBER(S)
CRHEATER101A00
CRHEATER102A00
CRHEATER103A00
CRHEATER104A00
(2) CRHEATER102A00
CRHEATER101A00
CRHEATER102A00
CRHEATER103A00
CRHEATER104A00
CRHEATER105A00
CRHEATER106A00
CRHEATER107A00
CRHEATER108A00
CRHEATER109A00
CRHEATER101A00
CRHEATER103A00
(2) CRHEATER102A00
(2) CRHEATER103A00
(2) CRHEATER104A00
CRHEATER102A00
CRHEATER103A00
CRHEATER105A00
(2) CRHEATER104A00
CRHEATER106A00
CRHEATER108A00
CRHEATER109A00
(2) CRHEATER108A00
CRHEATER102A00
CRHEATER103A00
(2) CRHEATER102A00
(2) CRHEATER103A00
(2) CRHEATER104A00
CRHEATER102A00
CRHEATER104A00
CRHEATER105A00
(2) CRHEATER104A00
(1) CRHEATER104A00 and
(1) CRHEATER105A00
CRHEATER106A00
CRHEATER108A00
CRHEATER109A00
(2) CRHEATER108A00
(1) CRHEATER108A00 and
(1) CRHEATER109A00
CRHEATER102A00
CRHEATER104A00
CRHEATER105A00
(2) CRHEATER104A00
(1) CRHEATER104A00 and
(1) CRHEATER105A00
CRHEATER106A00
CRHEATER108A00
CRHEATER109A00
(2) CRHEATER108A00
(1) CRHEATER108A00 and
(1) CRHEATER109A00

Performance data 50HJ (cont)


ELECTRIC HEATER USAGE COBRA ENERGY RECOVERY UNITS 50HJ008-014 AND 62AQ200
UNIT SIZE
50HJ/62AQ

VOLTAGE
V-PH-60 Hz

208/230/240-3

kW AT EACH
VOLTAGE
7.8/ 9.6/10.4
12.0/14.7/16.0
18.6/22.8/24.8
24.0/29.4/32.0
31.8/39.0/42.4

008/200
460/480-3

12.8/13.9
15.2/16.5
25.6/27.8
30.4/33.0
38.4/41.7

208/230/240-3

7.8/ 9.6/10.4
12.0/14.7/16.0
18.6/22.8/24.8
24.0/29.4/32.0
31.8/39.0/42.4

009/200
460/480-3

12.8/13.9
15.2/16.5
25.6/27.8
30.4/33.0
38.4/41.7
7.8/ 9.6/10.4
12.0/14.7/16.0
24.0/29.4/32.0

208/230/240-3

31.8/38.9/42.4
37.5/46.0/50.0

012/200

12.8/13.9
15.2/16.5
30.4/33.0
460/480-3

38.4/41.7
46.0/50.0
7.8/ 9.6/10.4
12.0/14.7/16.0
24.0/29.4/32.0

208/230/240-3

31.8/38.9/42.4
37.5/46.0/50.0

014/200

12.8/13.9
15.2/16.5
30.4/33.0
460/480-3

38.4/41.7
46.0/50.0

50HJ

FIOP
UL

LEGEND
Factory-Installed Option
Underwriters Laboratories

*For use with standard motor without convenience outlet only, when
utilizing high-static motors or 115-volt convenience outlet FIOP,
CRSINGLE009A00 must be used.
When utilizing 115-volt convenience outlet FIOP with high-static
motor, CRSINGLE008A00 must be used.
**For use with standard motor without convenience outlet only, when
utilizing high-static motors or 115-volt convenience outlet FIOP,
CRSINGLE015A00 must be used.
When utilizing 115-volt convenience outlet FIOP with high-static
motor, CRSINGLE014A00 must be used.
***When utilizing 115-volt convenience outlet FIOP with high-static
motor, CRSINGLE016A00 must be used.

220

REQUIRED HEATER
PART NUMBER(S)
CRHEATER117A00
CRHEATER110A00
CRHEATER111A00
CRHEATER112A00
(1) CRHEATER112A00 and
(1) CRHEATER117A00
CRHEATER116A00
CRHEATER113A00
CRHEATER114A00
CRHEATER115A00
(1) CRHEATER114A00 and
(1) CRHEATER116A00
CRHEATER117A00
CRHEATER110A00
CRHEATER111A00
CRHEATER112A00
(1) CRHEATER112A00 and
(1) CRHEATER117A00
CRHEATER116A00
CRHEATER113A00
CRHEATER114A00
CRHEATER115A00
(1) CRHEATER114A00 and
(1) CRHEATER116A00
CRHEATER117A00
CRHEATER110A00
CRHEATER112A00
(1) CRHEATER112A00 and
(1) CRHEATER117A00
(1) CRHEATER112A00 and
(1) CRHEATER110A00
CRHEATER116A00
CRHEATER113A00
CRHEATER115A00
(1) CRHEATER114A00 and
(1) CRHEATER116A00
(1) CRHEATER115A00 and
(1) CRHEATER113A00
CRHEATER117A00
CRHEATER110A00
CRHEATER112A00
(1) CRHEATER112A00 and
(1) CRHEATER117A00
(1) CRHEATER112A00 and
(1) CRHEATER110A00
CRHEATER116A00
CRHEATER113A00
CRHEATER115A00
(1) CRHEATER114A00 and
(1) CRHEATER116A00
(1) CRHEATER115A00 and
(1) CRHEATER113A00

SINGLE-POINT ELECTRIC HEATER


PACKAGES PART NUMBER
CRSINGLE007A00
CRSINGLE007A00*
CRSINGLE009A00
CRSINGLE009A00
CRSINGLE009A00
CRSINGLE006A00*
CRSINGLE006A00
CRSINGLE006A00
CRSINGLE008A00
CRSINGLE010A00
CRSINGLE012A00
CRSINGLE012A00**
CRSINGLE015A00
CRSINGLE015A00
CRSINGLE015A00
CRSINGLE011A00
CRSINGLE011A00
CRSINGLE011A00
CRSINGLE014A00
CRSINGLE016A00
Standard on RTU
Standard on RTU
Standard on RTU
Standard on RTU
Standard on RTU
CRSINGLE011A00
CRSINGLE011A00
CRSINGLE014A00***
CRSINGLE016A00
CRSINGLE016A00
Standard on RTU
Standard on RTU
Standard on RTU
Standard on RTU
Standard on RTU
CRSINGLE011A00
CRSINGLE011A00
CRSINGLE014A00
CRSINGLE016A00
CRSINGLE016A00

For use with standard motor without convenience outlet only, when
utilizing 115-volt convenience outlet FIOP, CRSINGLE016A00 must
be used.
NOTES:
1. For those kWs where two heater packages are furnished, the opportunity exists for two-stage capabilities.
2. Non-fused disconnect switch cannot be used when rooftop electrical
ratings exceed 80 amps.
3. Only those heaters and combinations of heaters shown above are
UL approved.
4. CRSINGLE006A00 and CRSINGLE011A00 kits do not require
fuses.

ELECTRIC HEATER USAGE COBRA ENERGY RECOVERY UNITS 50HJ008-014 AND 62AQ300
UNIT SIZE
50HJ/62AQ

VOLTAGE
V-PH-60 Hz

208/230/240-3

kW AT EACH
VOLTAGE
7.8/ 9.6/10.4
12.0/14.7/16.0
18.6/22.8/24.8
24.0/29.4/32.0
31.8/39.0/42.4

008/300
460/480-3

12.8/13.9
15.2/16.5
25.6/27.8
30.4/33.0
38.4/41.7

208/230/240-3

7.8/ 9.6/10.4
12.0/14.7/16.0
18.6/22.8/24.8
24.0/29.4/32.0
31.8/39.0/42.4

009/300
460/480-3

12.8/13.9
15.2/16.5
25.6/27.8
30.4/33.0
38.4/41.7
7.8/ 9.6/10.4
12.0/14.7/16.0
24.0/29.4/32.0

208/230/240-3

31.8/38.9/42.4
37.5/46.0/50.0

012/300

12.8/13.9
15.2/16.5
30.4/33.0
460/480-3

38.4/41.7
46.0/50.0
7.8/ 9.6/10.4
12.0/14.7/16.0
24.0/29.4/32.0

208/230/240-3

31.8/38.9/42.4
37.5/46.0/50.0

014/300

12.8/13.9
15.2/16.5
30.4/33.0
460/480-3

38.4/41.7
46.0/50.0

FIOP
UL

LEGEND
Factory-Installed Option
Underwriters Laboratories

SINGLE-POINT ELECTRIC HEATER


PACKAGES PART NUMBER
CRSINGLE007A00
CRSINGLE007A00*
CRSINGLE009A00
CRSINGLE009A00
CRSINGLE009A00
CRSINGLE006A00
CRSINGLE006A00
CRSINGLE008A00
CRSINGLE008A00
CRSINGLE010A00
CRSINGLE012A00
CRSINGLE012A00
CRSINGLE015A00
CRSINGLE015A00
CRSINGLE015A00
CRSINGLE011A00
CRSINGLE011A00
CRSINGLE011A00
CRSINGLE014A00
CRSINGLE016A00
Standard on RTU
Standard on RTU
Standard on RTU
Standard on RTU
Standard on RTU
CRSINGLE011A00
CRSINGLE011A00
CRSINGLE014A00**
CRSINGLE016A00
CRSINGLE016A00
Standard on RTU
Standard on RTU
Standard on RTU
Standard on RTU
Standard on RTU
CRSINGLE011A00
CRSINGLE011A00
CRSINGLE014A00
CRSINGLE016A00
CRSINGLE016A00

For use with standard motor without convenience outlet only, when
utilizing 115-volt convenience outlet FIOP, CRSINGLE016A00 must
be used.
NOTES:
1. For those kWs where two heater packages are furnished, the opportunity exists for two-stage capabilities.
2. Non-fused disconnect switch cannot be used when rooftop electrical
ratings exceed 80 amps.
3. Only those heaters and combinations of heaters shown above are
UL approved.
4. CRSINGLE006A00 and CRSINGLE011A00 kits do not require
fuses.

221

50HJ

*For use with standard motor without convenience outlet only, when
utilizing high-static motors or 115-volt convenience outlet FIOP,
CRSINGLE009A00 must be used.
For use with standard motor without convenience outlet only, when
utilizing high-static motors or 115-volt convenience outlet FIOP,
CRSINGLE015A00 must be used.
**When utilizing 115-volt convenience outlet FIOP with high-static
motor, CRSINGLE016A00 must be used.

REQUIRED HEATER
PART NUMBER(S)
CRHEATER117A00
CRHEATER110A00
CRHEATER111A00
CRHEATER112A00
(1) CRHEATER112A00 and
(1) CRHEATER117A00
CRHEATER116A00
CRHEATER113A00
CRHEATER114A00
CRHEATER115A00
(1) CRHEATER114A00 and
(1) CRHEATER116A00
CRHEATER117A00
CRHEATER110A00
CRHEATER111A00
CRHEATER112A00
(1) CRHEATER112A00 and
(1) CRHEATER117A00
CRHEATER116A00
CRHEATER113A00
CRHEATER114A00
CRHEATER115A00
(1) CRHEATER114A00 and
(1) CRHEATER116A00
CRHEATER117A00
CRHEATER110A00
CRHEATER112A00
(1)CRHEATER112A00 and
(1)CRHEATER117A00
(1)CRHEATER112A00 and
(1)CRHEATER110A00
CRHEATER116A00
CRHEATER113A00
CRHEATER115A00
(1)CRHEATER114A00 and
(1)CRHEATER116A00
(1)CRHEATER115A00 and
(1)CRHEATER113A00
CRHEATER117A00
CRHEATER110A00
CRHEATER112A00
(1)CRHEATER112A00 and
(1)CRHEATER117A00
(1)CRHEATER112A00 and
(1)CRHEATER110A00
CRHEATER116A00
CRHEATER113A00
CRHEATER115A00
(1)CRHEATER114A00 and
(1)CRHEATER116A00
(1)CRHEATER115A00 and
(1)CRHEATER113A00

Electrical data 50HJ


50HJ004-014 STANDARD UNITS
UNIT
50HJ

NOMINAL
V-PH-Hz

208/230-1-60

IFM
TYPE

CONV
OUTLET

VOLTAGE COMP NO. 1


RANGE
Min Max RLA

LRA

ELECTRIC HEAT
OFM IFM
FLA FLA CRHEATER Nominal
FLA
---A00
kW

NO

187

254

16.0

88.0

0.7

4.9

YES

187

254

16.0

88.0

0.7

4.9

NO

187

254

10.3

77.0

0.7

4.9

YES

187

254

10.3

77.0

0.7

4.9

NO

187

254

10.3

77.0

0.7

5.8

YES

187

254

10.3

77.0

0.7

5.8

NO

414

508

5.1

39.0

0.4

2.2

YES

414

508

5.1

39.0

0.4

2.2

NO

414

508

5.1

39.0

0.4

2.6

YES

414

508

5.1

39.0

0.4

2.6

NO
YES
NO
YES

518
518
518
518

632
632
632
632

4.2
4.2
4.2
4.2

31.0
31.0
31.0
31.0

0.4
0.4
0.4
0.4

2.2
2.2
2.6
2.6

NO

197

254

23.7

126.0

0.7

4.9

YES

197

254

23.7

126.0

0.7

4.9

NO

187

254

13.5

93.0

0.7

4.9

YES

187

254

13.5

93.0

0.7

4.9

NO

187

254

13.5

93.0

0.7

5.8

YES

187

254

13.5

93.0

0.7

5.8

STD

STD

208/230-3-60

HIGH STATIC

004
(3 Tons)

STD

460-3-60

HIGH STATIC

STD
575-3-60
HIGH STATIC

50HJ

208/230-1-60

005
(4 Tons)

STD

STD

208/230-3-60

HIGH STATIC

See Legend and Notes on page 223.

222

001
002
003
004
002+002

001
002
003
004
002+002

001
002
003
004
005

001
002
003
004
005

001
002
003
004
005

001
002
003
004
005

006
007
008
009

006
007
008
009

006
007
008
009

006
007
008
009

001
003
002+002
003+003
004+004

001
003
002+002
003+003
004+004

002
003
005
004+004

002
003
005
004+004

002
003
005
004+004

002
003
005
004+004

/
3.3/ 4.4
4.9/ 6.5
6.5/ 8.7
7.9/10.5
9.8/13.0
/
3.3/ 4.4
4.9/ 6.5
6.5/ 8.7
7.9/10.5
9.8/13.0
/
3.3/ 4.4
4.9/ 6.5
6.5/ 8.7
7.9/10.5
12.0/16.0
/
3.3/ 4.4
4.9/ 6.5
6.5/ 8.7
7.9/10.5
12.0/16.0
/
3.3/ 4.4
4.9/ 6.5
6.5/ 8.7
7.9/10.5
12.0/16.0
/
3.3/ 4.4
4.9/ 6.5
6.5/ 8.7
7.9/10.5
12.0/16.0

6.0
8.8
11.5
14.0

6.0
8.8
11.5
14.0

6.0
8.8
11.5
14.0

6.0
8.8
11.5
14.0

/
3.3/ 4.4
6.5/ 8.7
9.8/13.0
13.1/17.4
16.0/21.0
/
3.3/ 4.4
6.5/ 8.7
9.8/13.0
13.1/17.4
16.0/21.0
/
4.9/ 6.5
6.5/ 8.7
12.0/16.0
16.0/21.0
/
4.9/ 6.5
6.5/ 8.7
12.0/16.0
16.0/21.0
/
4.9/ 6.5
6.5/ 8.7
12.0/16.0
16.0/21.0
/
4.9/ 6.5
6.5/ 8.7
12.0/16.0
16.0/21.0

/
15.9/18.3
23.5/27.1
31.4/36.3
37.9/43.1
46.9/54.2
/
15.9/18.3
23.5/27.1
31.4/36.3
37.9/43.1
46.9/54.2
/
9.2/10.6
13.6/15.6
18.1/20.9
21.9/25.3
33.4/38.5
/
9.2/10.6
13.6/15.6
18.1/20.9
21.9/25.3
33.4/38.5
/
9.2/10.6
13.6/15.6
18.1/20.9
21.9/25.3
33.4/38.5
/
9.2/10.6
13.6/15.6
18.1/20.9
21.9/25.3
33.4/38.5

7.2
10.6
13.8
16.8

7.2
10.6
13.8
16.8

7.2
10.6
13.8
16.8

7.2
10.6
13.8
16.8

/
15.9/18.3
31.4/36.3
46.9/54.2
62.8/72.5
75.8/87.5
/
15.9/18.3
31.4/36.3
46.9/54.2
62.8/72.5
75.8/87.5
/
13.6/15.6
18.1/20.9
33.4/38.5
43.8/50.5
/
13.6/15.6
18.1/20.9
33.4/38.5
43.8/50.5
/
13.6/15.6
18.1/20.9
33.4/38.5
43.8/50.5
/
13.6/15.6
18.1/20.9
33.4/38.5
43.8/50.5

POWER SUPPLY*
MCA
25.6/ 25.6
26.0/ 29.0
35.5/ 40.0
45.4/ 51.4
53.5/ 60.0
64.8/ 73.8
31.6/ 31.6
31.6/ 34.0
40.5/ 45.0
50.4/ 56.4
58.5/ 65.0
69.8/ 78.8
18.5/ 18.5
18.5/ 19.4
23.1/ 25.7
28.8/ 32.3
33.5/ 37.7
47.8/ 54.2
24.5/ 24.5
24.5/ 24.5
28.1/ 30.7
33.8/ 37.3
38.5/ 42.7
52.8/ 59.2
19.4/ 19.4
19.4/ 20.5
24.2/ 26.8
29.9/ 33.4
34.6/ 38.8
48.9/ 55.4
25.4/ 25.4
25.4/ 25.5
29.2/ 31.8
34.9/ 38.4
39.6/ 43.8
53.9/ 60.4
9.0
11.8
16.0
20.0
23.8
11.7
15.1
18.7
22.7
26.5
9.4
12.3
16.5
20.5
24.3
12.1
15.6
19.2
23.2
27.0
7.3
9.5
7.7
9.8
35.2/ 35.2
35.2/ 35.2
45.4/ 51.4
64.8/ 73.8
84.7/ 96.8
100.9/115.5
41.2/ 41.2
41.2/ 41.2
50.4/ 56.4
69.8/ 78.8
89.7/101.8
105.9/120.5
22.5/ 22.5
23.1/ 25.7
28.8/ 32.3
47.8/ 54.2
60.8/ 69.3
28.5/ 28.5
28.5/ 30.7
33.8/ 37.3
52.8/ 59.2
65.8/ 74.3
23.4/ 23.4
24.2/ 26.8
29.9/ 33.4
48.9/ 55.4
62.0/ 70.4
29.4/ 29.4
29.4/ 31.8
34.9/ 38.4
53.9/ 60.4
67.0/ 75.4

Fuse or
HACR
Bkr
30/30
30/30
40/40
50/60
60/60

35/35
35/35
45/45
60/60

25/25
25/25
25/30
30/35
35/40
50/60
30/30
30/30
30/35
35/40
40/45
60/60
25/25
25/25
30/30
35/35
35/40
50/60
30/30
30/30
35/35
40/40
40/45

20
20
20
25
25
20
20
20
25
30
20
20
20
25
25
20
20
20
25
30
20
20
20
20
45/45
45/45
50/60

50/50
50/50
60/60

30/30
30/30
30/35
50/60

35/35
35/35
35/40
60/60

30/30
30/30
35/35
50/60

35/35
35/35
40/40

MOCP

70/ 80

60/ 70
70/ 80

60/ 70

70/ 80
90/100
110/125

70/ 80
90/110
110/125

70/ 70

70/ 80

70/ 80

60/ 70
70/ 80

CRSINGLE
---A00

004

004
004

002

004
004
004

004
004
004

002

002

002

002
002

DISCONNECT
SIZE
FLA

LRA

25/ 25
25/ 27
33/ 37
42/ 47
49/ 55
60/ 68
30/ 30
30/ 32
38/ 42
47/ 53
55/ 61
65/ 73
18/ 18
18/ 18
21/ 24
26/ 30
31/ 35
44/ 50
24/ 24
24/ 24
27/ 29
32/ 35
36/ 40
50/ 55
19/ 19
19/ 19
22/ 25
28/ 31
32/ 36
45/ 51
25/ 25
25/ 25
28/ 30
33/ 36
37/ 41
51/ 56
9
11
15
18
22
11
13
17
21
24
9
11
15
19
22
12
14
18
21
25
7
9
8
10
34/ 34
34/ 34
42/ 47
60/ 68
78/ 89
93/106
39/ 39
39/ 39
47/ 53
65/ 73
83/ 95
98/112
22/ 22
22/ 24
26/ 30
44/ 50
56/ 64
27/ 27
27/ 29
32/ 35
50/ 55
62/ 69
23/ 23
23/ 25
28/ 31
45/ 51
57/ 65
29/ 29
29/ 30
33/ 36
51/ 56
63/ 70

101/101
101/101
101/101
101/101
101/101
101/101
106/106
106/106
106/106
106/106
106/106
106/106
90/ 90
90/ 90
90/ 90
90/ 90
90/ 90
90/ 90
95/ 95
95/ 95
95/ 95
95/ 95
95/ 95
95/ 95
120/120
120/120
120/120
120/120
120/120
120/120
124/124
124/124
124/124
124/124
124/124
124/124
46
46
46
46
46
48
48
48
48
48
60
60
60
60
60
62
63
63
63
63
36
30
48
49
139/139
139/139
139/139
139/139
139/139
139/139
144/144
144/144
144/144
144/144
144/144
144/144
106/106
106/106
106/106
106/106
106/106
111/111
111/111
111/111
111/111
111/111
136/136
136/136
136/136
136/136
136/136
140/140
140/140
140/140
140/140
140/140

50HJ004-014 STANDARD UNITS (cont)


UNIT
50HJ

NOMINAL
V-PH-Hz

IFM
TYPE

CONV
OUTLET

VOLTAGE
RANGE
Min

Max

COMP NO. 1
RLA

LRA

ELECTRIC HEAT
OFM
FLA

IFM
FLA

NO

414

508

6.4

46.5

0.4

2.2

YES

414

508

6.4

46.5

0.4

2.2

NO

414

508

6.4

46.5

0.4

2.6

YES

414

508

6.4

46.5

0.4

2.6

NO
YES
NO
YES

518
518
518
518

632
632
632
632

6.4
6.4
6.4
6.4

40.0
40.0
40.0
40.0

0.4
0.4
0.4
0.4

2.2
2.2
2.6
2.6

STD

460-3-60
005
(4 Tons)
(cont)
HIGH STATIC

STD
575-3-60
HIGH STATIC

FLA
HACR
IFM
LRA
MCA
MOCP
NEC
OFM
RLA
UL

LEGEND
Full Load Amps
Heating, Air Conditioning and Refrigeration
Indoor (Evaporator) Fan Motor
Locked Rotor Amps
Minimum Circuit Amps
Maximum Overcurrent Protection
National Electrical Code
Outdoor (Condenser) Fan Motor
Rated Load Amps
Underwriters Laboratories

POWER SUPPLY*

CRHEATER
---A00

Nominal
kW

FLA

MCA

006
008
009
008+008

006
008
009
008+008

006
008
009
008+008

006
008
009
008+008

6.0
11.5
14.0
23.0

6.0
11.5
14.0
23.0

6.0
11.5
14.0
23.0

6.0
11.5
14.0
23.0

7.2
13.8
16.8
27.7

7.2
13.8
16.8
27.7

7.2
13.8
16.8
27.7

7.2
13.8
16.8
27.7

10.6
11.8
20.0
23.8
37.3
13.3
15.1
22.7
26.5
40.0
11.0
12.3
20.5
24.3
37.8
13.7
15.6
23.2
27.0
40.5
10.1
12.2
10.4
12.6

Fuse or
HACR
Bkr
20
20
25
25
40
20
20
25
30
45
20
20
25
25
40
20
20
25
30
45
20
20
20
20

MOCP

CRSINGLE
---A00

DISCONNECT
SIZE
FLA

LRA

10
11
18
22
34
13
13
21
24
37
11
11
19
22
35
13
14
21
25
37
10
12
10
12

53
54
54
54
54
55
56
56
56
56
67
68
68
68
68
70
70
70
70
70
45
47
57
58

Determine maximum deviation from average voltage.


(AB) 457 452 = 5 v
(BC) 464 457 = 7 v
(AC) 457 455 = 2 v
Maximum deviation is 7 v.
Determine percent of voltage imbalance.
% Voltage Imbalance = 100 x =

7
457

= 1.53%
This amount of phase imbalance is satisfactory as it is below the maximum allowable 2%.
IMPORTANT: If the supply voltage phase imbalance is more than 2%, contact your local electric utility company immediately.

*Used to determine minimum disconnect per NEC.


Heater capacity (kW) is based on heater voltage of 208 v, 240 v, 480 v or 600 v. If power distribution voltage to unit varies from rated heater voltage, heater kW will vary accordingly.
NOTES:
1. In compliance with NEC requirements for multimotor and combination load equipment (refer
to NEC Articles 430 and 440), the overcurrent protective device for the unit shall be fuse or
HACR breaker.
2. Unbalanced 3-Phase Supply Voltage
Never operate a motor where a phase imbalance in supply voltage is greater than 2%. Use
the following formula to determine the percent of voltage imbalance.
% Voltage Imbalance
max voltage deviation from average voltage
= 100 x
average voltage
Example: Supply voltage is 460-3-60.
AB = 452 v
BC = 464 v
AC = 455 v
Average Voltage =

452 + 464 + 455


3

1371
3
= 457

3. Non-fused disconnect switch cannot be used when rooftop unit electrical ratings exceed
80 amps.
4. 575-v units have UL, Canada approval only. Electric heaters are not available for 004-007,
575-v units.
5. For units with power exhaust: If a single power source is to be used, size wire to include
power exhaust MCA and MOCP.
Check MCA and MOCP when power exhaust is powered through the unit. Determine the
new MCA including the power exhaust using the following formula:
MCA New = MCA unit only + MCA of Power Exhaust
For example, using a 50HJ006---5 unit with MCA = 28.9 and MOCP = 35, with
CRPWREXH030A01 power exhaust.
MCA New = 28.9 amps + 1.6 amps = 30.5 amps
If the new MCA does not exceed the published MOCP, then MOCP would not change. The
MOCP in this example is 35 amps, the MCA New is below 35, therefore the MOCP is
acceptable. If MCA New is larger than the published MOCP, raise the MOCP to the next
larger size. For separate power, the MOCP for the power exhaust will be 15 amps per NEC.
POWER EXHAUST
PART NO.

MCA
(230 v)

MCA
(460 v)

MCA
(575 v)

CRPWREXH021A01
CRPWREXH022A01
CRPWREXH023A01
CRPWREXH028A01
CRPWREXH029A01
CRPWREXH030A01

N/A
3.4
N/A
1.7
N/A
1.6

0.68
N/A
1.4
N/A
0.7
N/A

N/A
1.32
N/A
0.68
N/A
0.64

MOCP
(for separate
power source)
15
15
15
15
15
15

N/A Not Available

50HJ
223

Electrical data 50HJ (cont)


50HJ004-014 STANDARD UNITS (cont)
UNIT
50HJ

NOMINAL
V-PH-Hz

208/230-1-60

IFM
TYPE

CONV
OUTLET

VOLTAGE COMP NO. 1


RANGE
Min Max

RLA

LRA

ELECTRIC HEAT
OFM IFM
FLA FLA CRHEATER Nominal
FLA
---A00
kW

NO

187

254

28.8

169.0

1.5

8.8

YES

187

254

28.8

169.0

1.5

8.8

NO

187

254

17.3

123.0

1.5

5.8

YES

187

254

17.3

123.0

1.5

5.8

NO

187

254

17.3

123.0

1.5

7.5

YES

187

254

17.3

123.0

1.5

7.5

NO

414

508

9.0

62.0

0.8

2.6

YES

414

508

9.0

62.0

0.8

2.6

NO

414

508

9.0

62.0

0.8

3.4

YES

414

508

9.0

62.0

0.8

3.4

NO
YES
NO
YES

518
518
518
518

632
632
632
632

7.1
7.1
7.1
7.1

50.0
50.0
50.0
50.0

0.8
0.8
0.8
0.8

2.6
2.6
3.4
3.4

NO

187

254

20.5

156.0

1.4

5.8

YES

187

254

20.5

156.0

1.4

5.8

NO

187

254

20.5

156.0

1.4

7.5

YES

187

254

20.5

156.0

1.4

7.5

STD

STD

208/230-3-60

HIGH STATIC
006
(5 Tons)

STD

460-3-60

HIGH STATIC

STD
575-3-60
HIGH STATIC

50HJ

STD

007
(6 Tons) 208/230-3-60

HIGH STATIC

See Legend and Notes on page 225.

224

002
003
002+002
003+003
004+004

002
003
002+002
003+003
004+004

002
004
005
004+004
004+005

002
004
005
004+004
004+005

002
004
005
004+004
004+005

002
004
005
004+004
004+005

006
008
009
008+008
008+009

006
008
009
008+008
008+009

006
008
009
008+008
008+009

006
008
009
008+008
008+009

002
004
005
004+004
004+005

002
004
005
004+004
004+005

002
004
005
004+004
004+005

002
004
005
004+004
004+005

/
4.9/ 6.5
6.5/ 8.7
8.7/13.0
13.0/17.4
15.8/21.0
/
4.9/ 6.5
6.5/ 8.7
8.7/13.0
13.0/17.4
15.8/21.0
/
4.9/ 6.5
7.9/10.5
12.0/16.0
15.8/21.0
19.9/26.5
/
4.9/ 6.5
7.9/10.5
12.0/16.0
15.8/21.0
19.9/26.5
/
4.9/ 6.5
7.9/10.5
12.0/16.0
15.8/21.0
19.9/26.5
/
4.9/ 6.5
7.9/10.5
12.0/16.0
15.8/21.0
19.9/26.5

6.0
11.5
14.0
23.0
25.5

6.0
11.5
14.0
23.0
25.5

6.0
11.5
14.0
23.0
25.5

6.0
11.5
14.0
23.0
25.5

/
4.9/ 6.5
7.9/10.5
12.0/16.0
15.8/21.0
19.9/26.5
/
4.9/ 6.5
7.9/10.5
12.0/16.0
15.8/21.0
19.9/26.5
/
4.9/ 6.5
7.9/10.5
12.0/16.0
15.8/21.0
19.9/26.5
/
4.9/ 6.5
7.9/10.5
12.0/16.0
15.8/21.0
19.9/26.5

/
23.5/27.1
31.4/36.3
46.9/54.2
62.8/72.5
75.8/87.5
/
23.5/27.1
31.4/36.3
46.9/54.2
62.8/72.5
75.8/87.5
/
13.6/15.6
21.9/25.3
33.4/38.5
43.8/50.5
55.2/63.8
/
13.6/15.6
21.9/25.3
33.4/38.5
43.8/50.5
55.2/63.8
/
13.6/15.6
21.9/25.3
33.4/38.5
43.8/50.5
55.2/63.8
/
13.6/15.6
21.9/25.3
33.4/38.5
43.8/50.5
55.2/63.8

7.2
13.8
16.8
27.7
30.1

7.2
13.8
16.8
27.7
30.1

7.2
13.8
16.8
27.7
30.1

7.2
13.8
16.8
27.7
30.1

/
13.6/15.6
21.9/25.3
33.4/38.5
43.8/50.5
55.2/63.8
/
13.6/15.6
21.9/25.3
33.4/38.5
43.8/50.5
55.2/63.8
/
13.6/15.6
21.9/25.3
33.4/38.5
43.8/50.5
55.2/63.8
/
13.6/15.6
21.9/25.3
33.4/38.5
43.8/50.5
55.2/63.8

POWER SUPPLY*
MCA
46.3/ 46.3
46.3/ 46.3
50.3/ 56.3
69.7/ 78.7
89.5/101.6
105.8/120.4
52.3/ 52.3
52.3/ 52.3
55.3/ 61.3
74.7/ 83.7
94.5/106.6
110.8/125.4
28.9/ 28.9
28.9/ 28.9
34.6/ 38.8
48.9/ 55.4
62.0/ 70.4
76.3/ 86.9
34.9/ 34.9
34.9/ 34.9
39.6/ 43.8
53.9/ 60.4
67.0/ 75.4
81.3/ 91.9
30.6/ 30.6
30.6/ 30.6
36.7/ 40.9
51.1/ 57.5
64.1/ 72.5
78.4/ 89.1
36.6/ 36.6
36.6/ 36.6
41.7/ 45.9
56.1/ 62.5
69.1/ 77.5
83.4/ 94.1
14.7
14.7
20.5
24.3
37.8
40.8
17.4
17.4
23.2
27.0
40.5
43.5
15.5
15.5
21.5
25.3
38.8
41.8
18.2
18.2
24.2
28.0
41.5
44.5
11.6
13.8
12.2
14.4
32.8/ 32.8
32.8/ 32.8
34.6/ 38.8
48.9/ 55.4
62.0/ 70.4
76.3/ 86.9
38.8/ 38.8
38.8/ 38.8
39.6/ 43.8
53.9/ 60.4
67.0/ 75.4
81.3/ 91.9
34.5/ 34.5
34.5/ 34.5
36.7/ 40.9
51.1/ 57.5
64.1/ 72.5
78.4/ 89.1
40.5/ 40.5
40.5/ 40.5
41.7/ 45.9
56.1/ 62.5
69.1/ 77.5
83.4/ 94.1

Fuse or
HACR
MOCP
Bkr
60/60

60/60

60/60

70/ 80

90/110

110/125
60/60

60/60

60/ 70

80/ 90

100/110

125/150
35/35

35/35

35/40

50/60

70/ 80

80/ 90
40/40

40/40

40/45

60/ 70

70/ 80

90/100
35/35

35/35

40/45

60/60

70/ 80

80/ 90
40/40

40/40

45/50

60/ 70

70/ 80

90/100
20

20

25

25

40

45

20

20

25

30

45

45

20

20

25

30

40

45

20

20

25.

30

45

45

20

20

20

20

40/40

40/40

40/40

50/60

70/ 80

80/ 90
45/45

45/45

45/45

60/ 70

70/ 80

90/100
40/40

40/40

40/45

60/60

70/ 80

80/ 90
45/45

45/45

45/50

60/ 70

70/ 80

90/100

CRSINGLE
---A00

004
004
004

004
004
004
004

002
002

002
002
002

002
002

002
002
002

002
002

002
002
002

002
002

002
002
002

DISCONNECT
SIZE
FLA

LRA

45/ 45
45/ 45
46/ 52
64/ 72
82/ 93
97/111
50/ 50
50/ 50
52/ 57
70/ 78
88/ 99
103/116
28/ 28
28/ 28
32/ 36
45/ 51
57/ 65
70/ 80
34/ 34
34/ 34
37/ 41
51/ 56
63/ 70
76/ 86
30/ 30
30/ 30
34/ 38
47/ 53
59/ 67
72/ 82
36/ 36
36/ 36
39/ 43
53/ 58
65/ 72
78/ 87
14
10
19
22
35
38
17
17
21
25
37
40
15
15
20
23
36
38
18
18
22
26
38
41
11
13
12
14
32/ 32
32/ 32
32/ 36
45/ 51
57/ 65
70/ 80
37/ 37
37/ 37
37/ 41
51/ 56
63/ 70
76/ 86
34/ 34
34/ 34
34/ 38
47/ 53
59/ 67
72/ 82
39/ 39
39/ 39
39/ 43
53/ 58
65/ 72
78/ 87

216/216
216/216
216/216
216/216
216/216
216/216
221/221
221/221
221/221
221/221
221/221
221/221
168/168
168/168
168/168
168/168
168/168
168/168
173/173
173/173
173/173
173/173
173/173
173/173
187/187
187/187
187/187
187/187
187/187
187/187
192/192
192/192
192/192
192/192
192/192
192/192
84
84
84
84
84
84
86
87
87
87
87
87
93
94
94
94
94
94
96
96
96
96
96
96
67
69
75
77
200/200
200/200
200/200
200/200
200/200
200/200
205/205
205/205
205/205
205/205
205/205
205/205
219/219
219/219
219/219
219/219
219/219
219/219
224/224
224/224
224/224
224/224
224/224
224/224

50HJ004-014 STANDARD UNITS (cont)


UNIT
50HJ

NOMINAL
V-PH-Hz

IFM
TYPE

CONV
OUTLET

VOLTAGE COMP NO. 1


RANGE
Min Max RLA

LRA

ELECTRIC HEAT
OFM IFM
FLA FLA CRHEATER Nominal
FLA
---A00
kW

NO

414

508

9.6

75.0

0.6

2.6

YES

414

508

9.6

75.0

0.6

2.6

NO

414

508

9.6

75.0

0.6

3.4

YES

414

508

9.6

75.0

0.6

3.4

NO
YES
NO
YES

518
518
518
518

632
632
632
632

7.7
7.7
7.7
7.7

56.0
56.0
56.0
56.0

0.6
0.6
0.6
0.6

2.6
2.6
3.4
3.4

STD

460-3-60
007
(6 Tons)
(cont)
HIGH STATIC

STD
575-3-60
HIGH STATIC

FLA
HACR
IFM
LRA
MCA
MOCP
NEC
OFM
RLA
UL

LEGEND
Full Load Amps
Heating, Air Conditioning and Refrigeration
Indoor (Evaporator) Fan Motor
Locked Rotor Amps
Minimum Circuit Amps
Maximum Overcurrent Protection
National Electrical Code
Outdoor (Condenser) Fan Motor
Rated Load Amps
Underwriters Laboratories

006
008
009
008+008
008+009

006
008
009
008+008
008+009

006
008
009
008+008
008+009

006
008
009
008+008
008+009

6.0
11.5
14.0
23.0
25.5

6.0
11.5
14.0
23.0
25.5

6.0
11.5
14.0
23.0
25.5

6.0
11.5
14.0
23.0
25.5

POWER SUPPLY*
MCA

7.2
13.8
16.8
27.7
30.7

7.2
13.8
16.8
27.7
30.7

7.2
13.8
16.8
27.7
30.7

7.2
13.8
16.8
27.7
30.7

15.2
15.2
20.5
24.3
37.8
41.6
17.9
17.9
23.2
27.0
40.5
44.3
16.0
16.0
21.5
25.3
38.8
42.6
18.7
18.7
24.2
28.0
41.5
45.3
12.2
14.3
12.8
15.0

Fuse or
HACR
Bkr
20
20
25
25
40
45
20
20
25
30
45
45
20
20
25
30
40
45
25
25
25
30
45
50
20
20
20
20

MOCP

CRSINGLE
---A00

DISCONNECT
SIZE
FLA

LRA

15
15
19
22
35
38
17
17
21
25
37
41
16
16
20
23
36
39
18
18
22
26
38
42
13
15
13
15

97
97
97
97
97
97
99
99
99
99
99
99
106
107
107
107
107
107
108
109
109
109
109
109
78
79
87
89

Determine maximum deviation from average voltage.


(AB) 457 452 = 5 v
(BC) 464 457 = 7 v
(AC) 457 455 = 2 v
Maximum deviation is 7 v.
Determine percent of voltage imbalance.
% Voltage Imbalance = 100 x =

7
457

= 1.53%
This amount of phase imbalance is satisfactory as it is below the maximum allowable 2%.
IMPORTANT: If the supply voltage phase imbalance is more than 2%, contact your local electric utility company immediately.

*Used to determine minimum disconnect per NEC.


Heater capacity (kW) is based on heater voltage of 208 v, 240 v, 480 v or 600 v. If power distribution voltage to unit varies from rated heater voltage, heater kW will vary accordingly.
NOTES:
1. In compliance with NEC requirements for multimotor and combination load equipment (refer
to NEC Articles 430 and 440), the overcurrent protective device for the unit shall be fuse or
HACR breaker.
2. Unbalanced 3-Phase Supply Voltage
Never operate a motor where a phase imbalance in supply voltage is greater than 2%. Use
the following formula to determine the percent of voltage imbalance.
% Voltage Imbalance
max voltage deviation from average voltage
= 100 x
average voltage
Example: Supply voltage is 460-3-60.
AB = 452 v
BC = 464 v
AC = 455 v
Average Voltage =

452 + 464 + 455


3

1371
3
= 457

3. Non-fused disconnect switch cannot be used when rooftop unit electrical ratings exceed
80 amps.
4. 575-v units have UL, Canada approval only. Electric heaters are not available for 004-007,
575-v units.
5. For units with power exhaust: If a single power source is to be used, size wire to include
power exhaust MCA and MOCP.
Check MCA and MOCP when power exhaust is powered through the unit. Determine the
new MCA including the power exhaust using the following formula:
MCA New = MCA unit only + MCA of Power Exhaust
For example, using a 50HJ006---5 unit with MCA = 28.9 and MOCP = 35, with
CRPWREXH030A01 power exhaust.
MCA New = 28.9 amps + 1.6 amps = 30.5 amps
If the new MCA does not exceed the published MOCP, then MOCP would not change. The
MOCP in this example is 35 amps, the MCA New is below 35, therefore the MOCP is
acceptable. If MCA New is larger than the published MOCP, raise the MOCP to the next
larger size. For separate power, the MOCP for the power exhaust will be 15 amps per NEC.
POWER EXHAUST
PART NO.

MCA
(230 v)

MCA
(460 v)

MCA
(575 v)

CRPWREXH021A01
CRPWREXH022A01
CRPWREXH023A01
CRPWREXH028A01
CRPWREXH029A01
CRPWREXH030A01

N/A
3.4
N/A
1.7
N/A
1.6

0.68
N/A
1.4
N/A
0.7
N/A

N/A
1.32
N/A
0.68
N/A
0.64

MOCP
(for separate
power source)
15
15
15
15
15
15

N/A Not Available

50HJ
225

Electrical data 50HJ (cont)


50HJ004-014 STANDARD UNITS (cont)
UNIT
50HJ

NOMINAL
V-PH-HZ

IFM
TYPE

CONV
OUTLET

VOLTAGE
RANGE
Min

Max

COMP NO. 1
RLA

LRA

COMP NO. 2
RLA

LRA

ELECTRIC HEATER
OFM
QTY

OFM
FLA

IFM
FLA

STD

NO

187

254

12.4

88.0

12.4

88.0

1.4

7.5

STD

YES

187

254

12.4

88.0

12.4

88.0

1.4

7.5

HIGH
STATIC

NO

187

254

12.4

88.0

12.4

88.0

1.4

10.6

HIGH
STATIC

YES

187

254

12.4

88.0

12.4

88.0

1.4

10.6

STD

NO

414

508

6.4

44.0

6.4

44.0

0.7

3.4

STD

YES

414

508

6.4

44.0

6.4

44.0

0.7

3.4

HIGH
STATIC

NO

414

508

6.4

44.0

6.4

44.0

0.7

4.8

HIGH
STATIC

YES

414

508

6.4

44.0

6.4

44.0

0.7

4.8

STD

NO

518

632

4.8

34.0

4.8

34.0

0.7

3.4

STD

YES

518

632

4.8

34.0

4.8

34.0

0.7

3.4

HIGH
STATIC

NO

518

632

4.8

34.0

4.8

34.0

0.7

4.8

HIGH
STATIC

YES

518

632

4.8

34.0

4.8

34.0

0.7

4.8

STD

NO

187

254

13.4

105.0

13.1

105.0

1.4

7.5

STD

YES

187

254

13.4

105.0

13.1

105.0

1.4

7.5

HIGH
STATIC

NO

187

254

13.4

105.0

13.1

105.0

1.4

10.6

HIGH
STATIC

YES

187

254

13.4

105.0

13.1

105.0

1.4

10.6

STD

NO

414

508

7.4

55.0

7.4

55.0

0.7

3.4

STD

YES

414

508

7.4

55.0

7.4

55.0

0.7

3.4

HIGH
STATIC

NO

414

508

7.4

55.0

7.4

55.0

0.7

4.8

HIGH
STATIC

YES

414

508

7.4

55.0

7.4

55.0

0.7

4.8

208/230-3-60

008

460-3-60

575-3-60

208/230-3-60

50HJ

009

460-3-60

See page 227 for legend and notes.

226

CRHEATER
---A00

Nominal
kW

FLA

017
010
011
012
012+017

017
010
011
012
012+017

017
010
011
012
012+017

017
010
011
012
012+017

016
013
014
015
014+016

016
013
014
015
014+016

016
013
014
015
014+016

016
013
014
015
014+016

018
019

018
019

018
019

018
019

017
010
011
012
012+017

017
010
011
012
012+017

017
010
011
012
012+017

017
010
011
012
012+017

016
013
014
015
014+016

016
013
014
015
014+016

016
013
014
015
014+016

016
013
014
015
014+016

7.8/10.4
12.0/16.0
18.6/24.8
24.0/32.0
31.8/42.4

7.8/10.4
12.0/16.0
18.6/24.8
24.0/32.0
31.8/42.4

7.8/10.4
12.0/16.0
18.6/24.8
24.0/32.0
31.8/42.4

7.8/10.4
12.0/16.0
18.6/24.8
24.0/32.0
31.8/42.4

13.9
16.5
27.8
33.0
41.7

13.9
16.5
27.8
33.0
41.7

13.9
16.5
27.8
33.0
41.7

13.9
16.5
27.8
33.0
41.7

17.0
34.0

17.0
34.0

17.0
34.0

17.0
34.0

7.8/10.4
12.0/16.0
18.6/24.8
24.0/32.0
31.8/42.4

7.8/10.4
12.0/16.0
18.6/24.8
24.0/32.0
31.8/42.4

7.8/10.4
12.0/16.0
18.6/24.8
24.0/32.0
31.8/42.4

7.8/10.4
12.0/16.0
18.6/24.8
24.0/32.0
31.8/42.4

13.9
16.5
27.8
33.0
41.7

13.9
16.5
27.8
33.0
41.7

13.9
16.5
27.8
33.0
41.7

13.9
16.5
27.8
33.0
41.7

/
21.7/ 25.0
33.4/ 38.5
51.7/ 59.7
66.7/ 77.0
88.4/102.0
/
21.7/ 25.0
33.4/ 38.5
51.7/ 59.7
66.7/ 77.0
88.4/102.0
/
21.7/ 25.0
33.4/ 38.5
51.7/ 59.7
66.7/ 77.0
88.4/102.0
/
21.7/ 25.0
33.4/ 38.5
51.7/ 59.7
66.7/ 77.0
88.4/102.0

16.7
19.8
33.4
39.7
50.2

16.7
19.8
33.4
39.7
50.2

16.7
19.8
33.4
39.7
50.2

16.7
19.8
33.4
39.7
50.2

16.4
32.7

16.4
32.7

16.4
32.7

16.4
32.7
/
21.7/ 25.0
33.4/ 38.5
51.7/ 59.7
66.7/ 77.0
88.4/102.0
/
21.7/ 25.0
33.4/ 38.5
51.7/ 59.7
66.7/ 77.0
88.4/102.0
/
21.7/ 25.0
33.4/ 38.5
51.7/ 59.7
66.7/ 77.0
88.4/102.0
/
21.7/ 25.0
33.4/ 38.5
51.7/ 59.7
66.7/ 77.0
88.4/102.0

16.7
19.8
33.4
39.7
50.2

16.7
19.8
33.4
39.7
50.2

16.7
19.8
33.4
39.7
50.2

16.7
19.8
33.4
39.7
50.2

POWER SUPPLY*
Fuse or
HACR
MOCP
Bkr
38.2/ 38.2
45/45

38.2/ 40.6
45/45

51.1/ 57.5
60/60

74.0/ 84.0

80/ 90
92.8/105.6

100/110
119.9/136.9

125/150
44.2/ 44.2
50/50

44.2/ 45.6
50/50

56.1/ 62.5

60/ 70
79.0/ 89.0

80/ 90
97.8/110.6

100/125
124.9/141.9

125/150
41.3/ 41.3
45/45

41.3/ 44.5
50/50

54.9/ 61.4

60/ 70
77.9/ 87.8

80/ 90
96.6/109.5

100/110
123.7/140.8

125/150
47.3/ 47.3
50/50

47.3/ 49.5
60/60

59.9/ 66.4

70/ 70
82.9/ 92.8

90/100
101.6/114.5

110/125
128.7/145.8

150/150
19.2
20

25.1
20

29.1
20

46.0
50

53.9
60

66.9

70
21.9
20

28.5
20

31.8
35

48.7
50

56.6
60

69.6

70
20.6
20

26.9
20

30.8
35

47.8
50

55.6
60

68.7

70
23.3
20

30.3
35

33.5
35

50.5
60

58.3
60

71.4

80
14.6
20

23.8
20

44.3
45

16.8
20

26.5
20

44.3
45

15.8
20

25.2
20

45.7
50

17.9
20

27.9
20

45.7
50

40.2/ 40.2
45/45

40.2/ 40.6
45/45

51.1/ 57.5
60/60

74.0/ 84.0

80/ 90
92.8/105.6

100/110
119.9/136.9

110/150
46.2/ 46.2
50/50

46.2/ 46.2
50/50

56.1/ 62.5

60/ 70
79.0/ 89.0

80/ 90
97.8/110.6

100/125
124.9/141.9

125/150
43.3/ 43.3
50/50

43.3/ 44.5
50/50

54.9/ 61.4

60/ 70
77.9/ 87.8

80/ 90
96.6/109.5

100/110
123.7/140.8

125/150
49.3/ 49.3
60/60

49.3/ 49.5
60/60

59.9/ 66.4

70/ 70
82.9/ 92.8

90/100
101.6/114.5

110/125
128.7/145.8

150/150
21.5
20

25.1
20

29.1
20

46.0
50

53.9
60

66.9

70
24.2
20

28.5
20

31.8
35

48.7
50

56.6
60

69.6

70
22.9
20

26.9
20

30.8
35

47.8
50

55.6
60

68.7

70
25.6
20

30.3
35

33.5
35

50.5
60

58.3
60

71.4

80
MCA

DISCONNECT
SIZE
FLA

LRA

40/ 40
40/ 40
47/ 53
68/ 77
85/ 97
110/126
46/ 46
46/ 46
53/ 58
74/ 83
91/103
116/131
44/ 44
44/ 44
51/ 56
72/ 81
89/101
114/129
49/ 49
49/ 49
56/ 62
77/ 86
94/106
119/135
20
23
27
42
50
62
23
26
29
45
52
64
22
25
28
44
51
63
24
27
31
46
54
66
15
22
41
17
24
43
17
23
42
19
25
44
42/ 42
42/ 42
47/ 53
68/ 77
85/ 97
110/126
48/ 48
48/ 48
53/ 58
74/ 83
91/103
116/131
46/ 46
46/ 46
51/ 56
72/ 81
89/101
114/129
51/ 51
51/ 51
56/ 62
77/ 86
94/106
119/135
23
23
27
42
50
62
25
26
29
45
52
64
24
25
28
44
51
63
27
27
31
46
54
66

242/242
242/242
242/242
242/242
242/242
242/242
247/247
247/247
247/247
247/247
247/247
247/247
267/267
267/267
267/267
267/267
267/267
267/267
271/271
271/271
271/271
271/271
271/271
271/271
121
121
121
121
121
121
123
123
123
123
123
123
133
134
134
134
134
134
135
136
136
136
136
136
94
95
95
96
96
96
104
104
104
106
106
106
276/276
276/276
276/276
276/276
276/276
276/276
281/281
281/281
281/281
281/281
281/281
281/281
301/301
301/301
301/301
301/301
301/301
301/301
305/305
305/305
305/305
305/305
305/305
305/305
143
143
143
143
143
143
145
145
145
145
145
145
155
156
156
156
156
156
157
158
158
158
158
158

50HJ004-014 STANDARD UNITS (cont)


UNIT
50HJ

NOMINAL
V-PH-HZ

009
(cont)

IFM
TYPE

CONV
OUTLET

VOLTAGE
RANGE
Min

Max

COMP NO. 1
RLA

LRA

COMP NO. 2
RLA

LRA

OFM
QTY

OFM
FLA

ELECTRIC HEATER
IFM
Nominal
FLA CRHEATER
FLA
---A00
kW

MCA

FLA

LRA

17.0
34.0

16.4
32.7

18.2
23.8
44.3

20
20
45

19
22
41

114
115
115

MOCP

STD

NO

518

632

6.4

44.0

6.4

44.0

0.7

3.4

STD

YES

518

632

6.4

44.0

6.4

44.0

0.7

3.4

018
019

17.0
34.0

16.4
32.7

20.4
26.5
46.9

25
25
50

21
24
43

116
116
116

HIGH
STATIC

NO

518

632

6.4

44.0

6.4

44.0

0.7

3.4

018
019

17.0
34.0

16.4
32.7

18.2
23.8
44.3

20
20
45

19
22
41

114
115
115

HIGH
STATIC

YES

518

632

6.4

44.0

6.4

44.0

0.7

4.8

018
019

17.0
34.0

16.4
32.7

21.5
27.9
48.3

25
25
50

22
25
44

126
126
126

575-3-60

DISCONNECT
SIZE

Fuse or
HACR
Bkr

018
019

Determine maximum deviation from average voltage.


(AB) 457 452 = 5 v
(BC) 464 457 = 7 v
(AC) 457 455 = 2 v
Maximum deviation is 7 v.
Determine percent of voltage imbalance.

LEGEND
FLA
HACR
IFM
LRA
MCA
MOCP
NEC
OFM
RLA
UL

POWER SUPPLY*

Full Load Amps


Heating, Air Conditioning and Refrigeration
Indoor (Evaporator) Fan Motor
Locked Rotor Amps
Minimum Circuit Amps
Maximum Overcurrent Protection
National Electrical Code
Outdoor (Condenser) Fan Motor
Rated Load Amps
Underwriters Laboratories

% Voltage Imbalance

= 100 x =

7
457

= 1.53%
This amount of phase imbalance is satisfactory as it is below the maximum allowable 2%.
IMPORTANT: If the supply voltage phase imbalance is more than 2%, contact your local electric utility
company immediately.
3.
4.
5.

*Used to determine minimum disconnect per NEC.


Heater capacity (kW) is based on heater voltage of 208 v, 240 v, 480 v or 600 v. If power distribution
voltage to unit varies from rated heater voltage, heater kW will vary accordingly.
NOTES:
1. In compliance with NEC requirements for multimotor and combination load equipment (refer to NEC
Articles 430 and 440), the overcurrent protective device for the unit shall be fuse or HACR breaker.
2. Unbalanced 3-Phase Supply Voltage
Never operate a motor where a phase imbalance in supply voltage is greater than 2%. Use the following formula to determine the percent of voltage imbalance.
% Voltage Imbalance
= 100 x

max voltage deviation from average voltage


average voltage

Example: Supply voltage is 460-3-60.


AB = 452 v
BC = 464 v
AC = 455 v
Average Voltage =

452 + 464 + 455


3

Non-fused disconnect switch cannot be used when rooftop unit electrical ratings exceed 80 amps.
575-v units have UL, Canada approval only. Electric heaters are not available for 004-007, 575-v
units.
For units with power exhaust: If a single power source is to be used, size wire to include power
exhaust MCA and MOCP.
Check MCA and MOCP when power exhaust is powered through the unit. Determine the new MCA
including the power exhaust using the following formula:
MCA New = MCA unit only + MCA of Power Exhaust
For example, using a 50HJ006---5 unit with MCA = 28.9 and MOCP = 35, with CRPWREXH030A01
power exhaust.
MCA New = 28.9 amps + 1.6 amps = 30.5 amps
If the new MCA does not exceed the published MOCP, then MOCP would not change. The MOCP in
this example is 35 amps, the MCA New is below 35, therefore the MOCP is acceptable. If MCA
New is larger than the published MOCP, raise the MOCP to the next larger size. For separate
power, the MOCP for the power exhaust will be 15 amps per NEC.
POWER EXHAUST
PART NO.

MCA
(230 v)

MCA
(460 v)

MCA
(575 v)

CRPWREXH021A01
CRPWREXH022A01
CRPWREXH023A01
CRPWREXH028A01
CRPWREXH029A01
CRPWREXH030A01

N/A
3.4
N/A
1.7
N/A
1.6

0.68
N/A
1.4
N/A
0.7
N/A

N/A
1.32
N/A
0.68
N/A
0.64

MOCP
(for separate
power source)
15
15
15
15
15
15

N/A Not Available


=

1371
3

= 457

50HJ
227

Electrical data 50HJ (cont)


50HJ004-014 STANDARD UNITS (cont)
UNIT
50HJ

NOMINAL
V-PH-HZ

IFM
TYPE

CONV
OUTLET

VOLTAGE
RANGE
Min

Max

COMP NO. 1
RLA

LRA

COMP NO. 2
RLA

LRA

OFM
QTY

OFM
FLA

ELECTRIC HEATER
IFM
FLA CRHEATER Nominal
FLA
---A00
kW*

FLA

LRA

/
21.7/ 25.0
33.4/ 38.5
66.7/ 77.0
88.4/102.0
104.2/120.3

53.0/ 53.0
53.0/ 53.0
54.9/ 61.4
96.6/109.5
123.7/140.8
143.5/133.5

60/60
60/60

60/ 70
100/110
125/150
150/150

56/ 56
56/ 56
56/ 56
89/101
114/129
132/151

341/341
341/341
341/341
341/341
341/341
341/341

MOCP

NO

187

254

17.6

125.0

17.6

125.0

1.4

10.6

STD

YES

187

254

17.6

125.0

17.6

125.0

1.4

10.6

017
011
012
012+017
012+010

7.8/10.4
12.0/16.0
24.0/32.0
31.8/42.4
37.5/50.0

/
21.7/ 25.0
33.4/ 38.5
66.7/ 77.0
88.4/102.0
104.2/120.3

59.0/ 59.0
59.0/ 59.0
59.9/ 66.4
101.6/114.5
128.7/145.8
148.5/137.5

70/70

70/ 70
70/ 70
110/125
150/150
150/150

61/ 61
61/ 61
61/ 62
94/106
119/135
138/156

345/345
345/345
345/345
345/345
345/345
345/345

HIGH
STATIC

NO

187

254

17.6

125.0

17.6

125.0

1.4

15.0

017
011
012
012+017
012+010

7.8/10.4
12.0/16.0
24.0/32.0
31.8/42.4
37.5/50.0

/
21.7/ 25.0
33.4/ 38.5
66.7/ 77.0
88.4/102.0
104.2/120.3

57.4/ 57.4
57.4/ 57.4
60.4/ 66.9
102.1/115.0
129.2/146.3
149.0/139.0

70/70

70/ 70
70/ 80
110/125
150/150
150/175

61/ 61
61/ 61
61/ 62
94/106
119/135
137/156

364/364
364/364
364/364
364/364
364/364
364/364

HIGH
STATIC

YES

187

254

17.6

125.0

17.6

125.0

1.4

15.0

017
011
012
012+017
012+010

7.8/10.4
12.0/16.0
24.0/32.0
31.8/42.4
37.5/50.0

/
21.7/ 25.0
33.4/ 38.5
66.7/ 77.0
88.4/102.0
104.2/120.3

63.4/ 63.4
63.4/ 63.4
65.4/ 71.9
107.1/120.0
134.2/151.3
154.0/143.0

70/70

70/ 70
80/ 80
110/125
150/175
175/175

66/ 66
66/ 66
66/ 67
99/111
124/140
143/161

369/369
369/369
369/369
369/369
369/369
369/369

STD

NO

414

508

8.3

62.5

8.3

62.5

0.7

4.8

016
013
015
014+016
015+013

13.9
16.5
33.0
41.7
50.0

16.7
19.8
39.7
50.2
60.1

24.9
26.9
30.8
55.6
68.7
66.1

20
20
35
60

70
80

26
26
28
51
63
75

170
171
171
171
171
171

STD

YES

414

508

8.3

62.5

8.3

62.5

0.7

4.8

016
013
015
014+016
015+013

13.9
16.5
33.0
41.7
50.0

16.7
19.8
39.7
50.2
60.1

27.6
30.3
33.5
58.3
71.4
70.1

20
35
35
60

80
80

29
29
31
54
66
77

172
173
173
173
173
173

HIGH
STATIC

NO

414

508

8.3

62.5

8.3

62.5

0.7

7.4

016
013
015
014+016
015+013

13.9
16.5
33.0
41.7
50.0

16.7
19.8
39.7
50.2
60.1

27.5
30.1
34.1
58.9
71.9
69.4

20
35
40
60

80
80

29
29
31
54
66
78

182
182
182
182
182
182

HIGH
STATIC

YES

414

508

8.3

62.5

8.3

62.5

0.7

7.4

016
013
015
014+016
015+013

13.9
16.5
33.0
41.7
50.0

16.7
19.8
39.7
50.2
60.1

30.2
33.5
36.8
61.6
74.6
73.4

35
40
40

70
80
80

32
32
34
57
69
80

184
184
184
184
184
184

STD

NO

518

632

6.3

50.0

6.3

50.0

0.7

4.8

018
019
018+019

17.0
34.0
51.0

16.4
32.7
49.1

19.1
25.2
45.7
53.9

25
25
50
60

20
23
42
61

136
136
136
136

STD

YES

518

632

6.3

50.0

6.3

50.0

0.7

4.8

018
019
018+019

17.0
34.0
51.0

16.4
32.7
49.1

21.3
27.9
48.3
56.5

25
25
50
60

22
25
44
63

138
138
138
138

HIGH
STATIC

NO

518

632

6.3

50.0

6.3

50.0

0.7

7.4

018
019
018+019

17.0
34.0
51.0

16.4
32.7
49.1

21.2
27.8
48.3
56.5

25
25
50

70

23
26
44
63

145
146
146
146

HIGH
STATIC

YES

518

632

6.3

50.0

6.3

50.0

0.7

7.4

018
019
018+019

17.0
34.0
51.0

16.4
32.7
49.1

23.4
30.5
50.9
59.1

25
35
60

70

25
28
46
65

147
148
148
148

STD

NO

187

254

19.0

156.0

19.0

156.0

1.4

15.0

017
010
012
012+017
012+010

7.8/10.4
12.0/16.0
24.0/32.0
31.8/42.4
37.5/50.0

/
21.7/ 25.0
33.4/ 38.5
66.7/ 77.0
88.4/102.0
104.2/120.3

60.6/ 60.6
60.6/ 60.6
60.4/ 66.9
102.1/115.0
129.2/146.3
149.0/139.0

70/70

70/ 70
70/ 80
110/125
150/150
150/175

64/ 64
64/ 64
64/ 64
94/106
119/135
137/156

426/426
426/426
426/426
426/426
426/426
426/426

STD

YES

187

254

19.0

156.0

19.0

156.0

1.4

15.0

016
013
015
014+016
015+013

7.8/10.4
12.0/16.0
24.0/32.0
31.8/42.4
37.5/50.0

/
21.7/ 25.0
33.4/ 38.5
66.7/ 77.0
88.4/102.0
104.2/120.3

66.6/ 66.6
66.6/ 66.6
65.4/ 71.9
107.1/120.0
134.2/151.3
154.0/143.0

70/70

70/ 70
80/ 80
110/125
150/175
175/175

70/ 70
70/ 70
70/ 70
99/111
124/140
143/161

431/431
431/431
431/431
431/431
431/431
431/431

STD

NO

414

508

9.0

70.0

9.0

70.0

0.7

7.4

016
013
015
014+016
015+013

13.9
16.5
33.0
41.7
50.0

16.7
19.8
39.7
50.2
60.1

29.1
30.1
34.1
58.9
71.9
69.4

35
35
40
60

80
80

31
31
31
54
66
78

197
197
197
197
197
197

STD

YES

414

508

9.0

70.0

9.0

70.0

0.7

7.4

016
013
015
014+016
015+013

13.9
16.5
33.0
41.7
50.0

16.7
19.8
39.7
50.2
60.1

31.8
33.5
36.8
61.6
74.6
73.4

35
40
40

70
80
80

33
33
34
57
69
80

199
199
199
199
199
199

STD

NO

518

632

7.4

54.0

7.4

54.0

0.7

7.4

018
019
018+019

17.0
34.0
51.0

16.4
32.7
49.1

23.7
27.8
48.3
56.5

30
30
50

70

25
26
44
63

153
154
154
154

STD

YES

518

632

7.4

54.0

7.4

54.0

0.7

7.4

018
019
018+019

17.0
34.0
51.0

16.4
32.7
49.1

25.9
30.5
50.9
59.1

30
35
60

70

27
28
46
65

155
155
155
155

575-3-60

208/230-3-60

014
460-3-60

50HJ

MCA

7.8/10.4
12.0/16.0
24.0/32.0
31.8/42.4
37.5/50.0

STD

460-3-60

575-3-60

228

DISCONNECT
SIZE

Fuse or
HACR
Bkr

017
011
012
012+017
012+010

208/230-3-60

012

POWER SUPPLY*

COBRA ENERGY RECOVERY UNITS 50HJ004-007 UNITS WITH 62AQ060


UNIT
50HJ

NOMINAL
V-PH-Hz

IFM
TYPE

208/230-1-60

CONV
OUTLET

62AQ
FLA

9.2

YES

9.2

NO

9.2

YES

9.2

NO

9.2

YES

9.2

NO

9.2

YES

9.2

NO

9.2

YES

9.2

NO

9.2

YES

9.2

NO

9.2

YES

9.2

NO

9.2

YES

9.2

STD

STD

208/230-3-60

004
HIGH STATIC

STD

460-3-60

HIGH STATIC

208/230-1-60

STD

005
STD

208/230-3-60

HIGH STATIC

HEAT

NONE
001
002
003
004
002+002
NONE
001
002
003
004
002+002
NONE
001
002
003
004
005
NONE
001
002
003
004
005
NONE
001
002
003
004
005
NONE
001
002
003
004
005
NONE
006
007
008
009
NONE
006
007
008
009
NONE
006
007
008
009
NONE
006
007
008
009
NONE
001
003
002+002
003+003
004+004
NONE
001
003
002+002
003+003
004+004
NONE
002
003
005
004+004
NONE
002
003
005
004+004
NONE
002
003
005
004+004
NONE
002
003
005
004+004

/
15.9/18.3
23.5/27.1
31.4/36.3
37.9/43.8
46.9/54.2
/
15.9/18.3
23.5/27.1
31.4/36.3
37.9/43.8
46.9/54.2
/
9.2/10.6
13.6/15.6
18.1/20.9
21.9/25.3
33.4/38.5
/
9.2/10.6
13.6/15.6
18.1/20.9
21.9/25.3
33.4/38.5
/
9.2/10.6
13.6/15.6
18.1/20.9
21.9/25.3
33.4/38.5
/
9.2/10.6
13.6/15.6
18.1/20.9
21.9/25.3
33.4/38.5

7.2
10.6
13.8
16.8

7.2
10.6
13.8
16.8

7.2
10.6
13.8
16.8

7.2
10.6
13.8
16.8
/
15.9/18.3
31.4/36.3
46.9/54.2
62.8/72.5
75.8/87.5
/
15.9/18.3
31.4/36.3
46.9/54.2
62.8/72.5
75.8/87.5
/
13.6/15.6
18.1/20.9
33.4/38.5
43.8/50.5
/
13.6/15.6
18.1/20.9
33.4/38.5
43.8/50.5
/
13.6/15.6
18.1/20.9
33.4/38.5
43.8/50.5
/
13.6/15.6
18.1/20.9
33.4/38.5
43.8/50.5

FLA

POWER SUPPLY*
Fuse or
HACR Bkr
34.8/ 34.8
40/40
35.7/ 38.8
40/45
45.2/ 49.7
50/50
55.1/ 61.2

63.2/ 70.5

74.5/ 83.6

40.8/ 40.8
45/45
40.8/ 43.0
45/50
50.0/ 53.9
60/60
59.9/ 65.4

68.0/ 74.7

79.3/ 87.8

27.7/ 27.7
35/35
27.7/ 29.1
35/35
32.8/ 35.4
40/40
38.5/ 42.0
45/45
43.2/ 47.4
45/50
57.5/ 64.0

33.7/ 33.7
40/35
33.7/ 33.7
40/40
37.6/ 39.6
45/45
43.3/ 46.2
50/50
48.0/ 51.6
50/60
62.3/ 68.2

28.6/ 28.6
35/35
28.6/ 30.0
35/35
33.7/ 36.3
40/40
39.4/ 42.9
45/45
44.1/ 48.3
50/50
58.4/ 64.9

34.6/ 34.6
40/40
34.6/ 34.6
40/40
38.5/ 40.5
45/45
44.2/ 47.1
50/50
48.9/ 52.5
60/60
63.2/ 69.1

13.6
20
16.7
20
20.9
25
25.0
25
28.7
30
16.3
20
18.8
25
23.0
25
27.1
30
30.8
35
14.0
20
17.1
20
21.3
25
25.4
30
29.1
30
16.7
20
19.2
25
23.4
25
27.5
30
31.2
35
44.4/ 44.4
60/60
44.4/ 44.4
60/60
55.1/ 61.2

74.5/ 83.6

94.4/106.5

110.6/125.2

50.4/ 50.4
60/60
50.4/ 50.4
60/60
59.9/ 65.4

79.3/ 87.8

99.2/110.7

115.4/129.4

31.7/ 31.7
40/40
32.8/ 35.4
40/40
38.5/ 42.0
45/45
57.5/ 64.0

70.6/ 79.0

37.7/ 37.7
40/40
37.7/ 39.6
45/45
43.3/ 46.2
50/50
62.3/ 68.2

75.4/ 83.2

32.6/ 32.6
40/40
33.7/ 36.3
40/40
39.4/ 42.9
45/45
58.4/ 64.9

71.5/ 79.9

38.6/ 38.6
45/45
38.6/ 40.5
45/45
44.2/ 47.1
50/50
63.2/ 69.1

76.3/ 84.1

MCA

MOCP

SINGLE
POINT BOX
CRSINGLE---A00

60/ 70
70/ 80
80/ 90

60/ 70
70/ 80
80/ 90

60/ 70

70/ 70

60/ 70

70/ 70

60/ 70
80/ 90
100/110
125/150

60/ 70
80/ 90
100/125
125/150

60/ 70
80/ 80

70/ 70
80/ 90

60/ 70
80/ 80

70/ 70
80/ 90

004
004
005

004
005
005

002

002

002

003

004
005
005
005

004
005
005
005

002
003

002
003

002
003

003
003

DISCONNECT SIZE
FLA

LRA

35/ 35
35/ 37
43/ 47
52/ 58
60/ 67
70/ 79
41/ 41
41/ 42
49/ 52
58/ 63
65/ 71
76/ 83
29/ 29
29/ 29
32/ 34
37/ 40
41/ 45
55/ 60
34/ 34
34/ 34
37/ 39
43/ 45
47/ 50
60/ 65
30/ 30
30/ 30
33/ 35
38/ 41
42/ 46
56/ 62
35/ 35
35/ 35
38/ 40
44/ 46
48/ 51
61/ 66
14
14
15
24
27
20
20
20
29
32
15
15
15
24
28
20
20
20
29
32
44/ 44
44/ 44
52/ 58
70/ 79
88/100
103/117
50/ 50
50/ 50
58/ 63
76/ 83
94/104
109/122
33/ 33
33/ 34
37/ 40
55/ 60
67/ 74
38/ 38
38/ 39
43/ 45
60/ 65
72/ 79
34/ 34
34/ 35
38/ 41
56/ 62
68/ 75
39/ 39
39/ 40
44/ 46
61/ 66
73/ 80

135/135
135/135
135/135
135/135
135/135
135/135
140/140
140/140
140/140
140/140
140/140
140/140
124/124
124/124
124/124
124/124
124/124
124/124
129/129
129/129
129/129
129/129
129/129
129/129
154/154
154/154
154/154
154/154
154/154
154/154
158/158
158/158
158/158
158/158
158/158
158/158
63
63
63
63
63
67
68
68
68
68
77
77
77
77
77
82
82
82
82
82
173/173
173/173
173/173
173/173
173/173
173/173
178/178
178/178
178/178
178/178
178/178
178/178
140/140
140/140
140/140
140/140
140/140
145/145
145/145
145/145
145/145
145/145
170/170
170/170
170/170
170/170
170/170
174/174
174/174
174/174
174/174
174/174

See legend and notes on page 230.

229

50HJ

NO

HEATER
CRHEATER
---A00

Electrical data 50HJ (cont)


COBRA ENERGY RECOVERY UNITS 50HJ004-007 UNITS WITH 62AQ060 (cont)
UNIT
50HJ

NOMINAL
V-PH-Hz

IFM
TYPE

CONV
OUTLET

62AQ
FLA

NO

9.2

YES

9.2

NO

9.2

YES

9.2

NO

9.2

YES

9.2

NO

9.2

YES

9.2

NO

9.2

YES

9.2

NO

9.2

YES

9.2

STD

005
(cont)

460-3-60

HIGH STATIC

208/230-1-60

STD

STD

006

208/230-3-60

HIGH STATIC

50HJ

460-3-60

STD

HEATER
CRHEATER
---A00
NONE
006
008
009
008+008
NONE
006
008
009
008+008
NONE
006
008
009
008+008
NONE
006
008
009
008+008
NONE
002
003
002+002
003+003
004+004
NONE
002
003
002+002
003+003
004+004
NONE
002
004
005
004+004
004+005
NONE
002
004
005
004+004
004+005
NONE
002
004
005
004+004
004+005
NONE
002
004
005
004+004
004+005
NONE
006
008
009
008+008
008+009
NONE
006
008
009
008+008
008+009

HEAT
FLA

7.2
13.8
16.8
27.7

7.2
13.8
16.8
27.7

7.2
13.8
16.8
27.7

7.2
13.8
16.8
27.7
/
23.5/27.1
31.4/36.3
46.9/54.2
62.8/72.5
75.8/87.5
/
23.5/27.1
31.4/36.3
46.9/54.2
62.8/72.5
75.8/87.5
/
13.6/15.6
21.9/25.3
33.4/38.5
43.8/50.5
55.2/63.8
/
13.6/15.6
21.9/25.3
33.4/38.5
43.8/50.5
55.2/63.8
/
13.6/15.6
21.9/25.3
33.4/38.5
43.8/50.5
55.2/63.8
/
13.6/15.6
21.9/25.3
33.4/38.5
43.8/50.5
55.2/63.8

7.2
13.8
16.8
27.7
30.7

7.2
13.8
16.8
27.7
30.7

LEGEND
FLA
Full Load Amps
HACR Heating, Air Conditioning and Refrigeration
IFM
Indoor (Evaporator) Fan Motor
LRA
Locked Rotor Amps
MCA Minimum Circuit Amps
MOCP Maximum Overcurrent Protection
NEC
National Electrical Code
UL
Underwriters Laboratories
*Used to determine minimum disconnect per NEC.
NOTES:
1. In compliance with NEC requirements for multimotor and combination load equipment (refer to NEC Articles 430 and 440), the overcurrent protective device for the
unit shall be fuse or HACR breaker. UL, Canada units may be fuse or circuit breaker.
2. Unbalanced 3-Phase Supply Voltage
Never operate a motor where a phase imbalance in supply voltage is greater than 2%.
Use the following formula to determine the percent of voltage imbalance.
max voltage deviation from average voltage
= 100 x
average voltage

POWER SUPPLY*
Fuse or
HACR Bkr
15.2
20
16.7
20
25.0
25
28.7
30
42.3
45
17.9
20
18.8
25
27.1
30
30.8
35
44.4
45
15.6
20
17.1
20
25.4
30
29.1
30
42.7
45
18.3
20
19.2
25
27.5
30
31.2
35
44.8
45
55.5/ 55.5
70/70
55.5/ 55.5

59.5/ 65.5

78.9/ 87.9

98.7/110.8

115.0/129.6

61.5/ 61.5
70/70
61.5/ 61.5

64.3/ 69.7

83.7/ 92.1

103.5/115.0

119.8/133.8

38.1/ 38.1
45/45
38.1/ 38.1
45/45
44.1/ 48.3
50/50
58.4/ 64.9

71.5/ 79.9

85.8/ 96.4

44.1/ 44.1
50/50
44.1/ 44.1
50/50
48.9/ 52.5
60/60
63.2/ 69.1

76.3/ 84.1

90.6/100.6

39.8/ 39.8
45/45
39.8/ 39.8
45/45
45.9/ 50.1
50/60
60.3/ 66.7

73.3/ 81.7

87.6/ 98.3

45.8/ 45.8
50/50
45.8/ 45.8
50/50
50.7/ 54.3
60/60
65.1/ 70.9

78.1/ 85.9

92.4/102.5

19.3
25
19.3
25
25.4
30
29.1
30
42.7
45
46.4
50
22.0
25
22.0
25
27.5
30
31.2
35
44.8
45
48.5
50
MCA

MOCP

70/ 70
70/ 70
80/ 90
100/125
125/150

70/ 70
70/ 70
90/100
110/125
125/150

60/ 70
80/ 80
90/100

70/ 70
80/ 90
100/110

70/ 70
80/ 90
90/100

70/ 80
80/ 90
100/110

SINGLE POINT
BOX
CRSINGLE---A00

025

025
025

025

025
025

004
004
005
005
005

004
005
005
005
005

002
003
003

003
003
003

003
003
003

003
003
003

025
025

025
025
025

DISCONNECT SIZE
FLA

LRA

16
16
18
27
40
21
21
21
32
44
16
16
19
28
40
22
22
22
32
45
56/ 56
56/ 56
57/ 62
75/ 83
93/104
108/121
61/ 61
61/ 61
62/ 67
80/ 88
98/109
113/126
39/ 39
39/ 39
42/ 46
56/ 62
68/ 75
81/ 91
44/ 44
44/ 44
48/ 51
61/ 66
73/ 80
86/ 95
41/ 41
41/ 41
44/ 48
58/ 63
70/ 77
83/ 93
46/ 46
46/ 46
50/ 53
63/ 68
75/ 82
88/ 97
20
20
20
28
40
44
25
25
25
32
45
48

70
71
71
71
71
75
75
75
75
75
84
85
85
85
85
89
90
90
90
90
250/250
250/250
250/250
250/250
250/250
250/250
255/255
255/255
255/255
255/255
255/255
255/255
202/202
202/202
202/202
202/202
202/202
202/202
207/207
207/207
207/207
207/207
207/207
207/207
221/221
221/221
221/221
221/221
221/221
221/221
226/226
226/226
226/226
226/226
226/226
226/226
101
101
101
101
101
101
106
106
106
106
106
106

Example: Supply voltage is 460-3-60.


AB = 452 v
BC = 464 v
AC = 455 v
452 + 464 + 455
3
1371
=
3
= 457
Determine maximum deviation from average voltage.
(AB) 457 452 = 5 v
(BC) 464 457 = 7 v
(AC) 457 455 = 2 v
Maximum deviation is 7 v.
Determine percent of voltage imbalance.
7
% Voltage Imbalance = 100 x
457
= 1.53%
This amount of phase imbalance is satisfactory as it is below the maximum allowable
2%.
Average Voltage =

IMPORTANT: If the supply voltage phase imbalance is more than 2%, contact your
local electric utility company immediately.

230

COBRA ENERGY RECOVERY UNITS 50HJ004-007 UNITS WITH 62AQ060 (cont)


UNIT
50HJ

006
(cont)

NOMINAL
V-PH-Hz

460-3-60

IFM
TYPE

CONV
OUTLET

62AQ
FLA

NO

9.2

YES

9.2

NO

9.2

YES

9.2

NO

9.2

YES

9.2

NO

9.2

YES

9.2

NO

9.2

YES

9.2

HIGH STATIC

STD

208/230-3-60

HIGH STATIC

007

STD

460-3-60

HIGH STATIC

FLA
HACR
IFM
LRA
MCA
MOCP
NEC
UL

HEATER
CRHEATER
---A00

HEAT

NONE
006
008
009
008+008
008+009
NONE
006
008
009
008+008
008+009
NONE
002
004
005
004+004
004+005
NONE
002
004
005
004+004
004+005
NONE
002
004
005
004+004
004+005
NONE
002
004
005
004+004
004+005
NONE
006
008
009
008+008
008+009
NONE
006
008
009
008+008
008+009
NONE
006
008
009
008+008
008+009
NONE
006
008
009
008+008
008+009

7.2
13.8
16.8
27.7
30.7

7.2
13.8
16.8
27.7
30.7
/
13.6/15.6
21.9/25.3
33.4/38.5
43.8/50.5
55.2/63.8
/
13.6/15.6
21.9/25.3
33.4/38.5
43.8/50.5
55.2/63.8
/
13.6/15.6
21.9/25.3
33.4/38.5
43.8/50.5
55.2/63.8
/
13.6/15.6
21.9/25.3
33.4/38.5
43.8/50.5
55.2/63.8

7.2
13.8
16.8
27.7
30.7

7.2
13.8
16.8
27.7
30.7

7.2
13.8
16.8
27.7
30.7

7.2
13.8
16.8
27.7
30.7

FLA

LEGEND
Full Load Amps
Heating, Air Conditioning and Refrigeration
Indoor (Evaporator) Fan Motor
Locked Rotor Amps
Minimum Circuit Amps
Maximum Overcurrent Protection
National Electrical Code
Underwriters Laboratories

*Used to determine minimum disconnect per NEC.

= 100 x

max voltage deviation from average voltage


average voltage

SINGLE
POINT BOX
CRSINGLE---A00

025
025

025
025
025

002
003
003

003
003
003

003
003
003

003
003
003

025
025

025
025
025

025
025

025
025
025

DISCONNECT SIZE
FLA

LRA

20
20
20
29
41
44
26
26
26
33
46
49
42/42
42/42
42/46
56/62
68/75
81/91
48/48
48/48
48/51
61/66
73/80
86/95
44/44
44/44
44/48
58/63
70/77
83/93
50/50
50/50
50/53
63/68
75/82
88/97
20
20
20
28
40
44
26
26
26
32
45
48
21
21
21
29
41
44
26
26
26
33
46
49

110
111
111
111
111
111
115
116
116
116
116
116
234/234
234/234
234/234
234/234
234/234
234/234
239/239
239/239
239/239
239/239
239/239
239/239
253/253
253/253
253/253
253/253
253/253
253/253
258/258
258/258
258/258
258/258
258/258
258/258
114
114
114
114
114
114
118
119
119
119
119
119
123
124
124
124
124
124
128
128
128
128
128
128

Example: Supply voltage is 460-3-60.


AB = 452 v
BC = 464 v
AC = 455 v
Average Voltage =
=

452 + 464 + 455


3
1371
3

= 457
Determine maximum deviation from average voltage.
(AB) 457 452 = 5 v
(BC) 464 457 = 7 v
(AC) 457 455 = 2 v
Maximum deviation is 7 v.
Determine percent of voltage imbalance.
7
% Voltage Imbalance = 100 x
457
= 1.53%
This amount of phase imbalance is satisfactory as it is below the maximum allowable
2%.
IMPORTANT: If the supply voltage phase imbalance is more than 2%, contact your
local electric utility company immediately.

231

50HJ

NOTES:
1. In compliance with NEC requirements for multimotor and combination load equipment (refer to NEC Articles 430 and 440), the overcurrent protective device for the
unit shall be fuse or HACR breaker. UL, Canada units may be fuse or circuit breaker.
2. Unbalanced 3-Phase Supply Voltage
Never operate a motor where a phase imbalance in supply voltage is greater than
2%. Use the following formula to determine the percent of voltage imbalance.

POWER SUPPLY*
Fuse or
MOCP
HACR Bkr
20.1
25

20.1
25

26.2
30

29.9
30

43.5
45

47.2
50

22.8
25

22.8
25

28.3
30

32.0
35

45.6
50

49.3
50

42.0/ 42.0
50/50

42.0/ 42.0
50/50

44.1/ 48.3
50/50

58.4/ 64.9

60/ 70
71.5/ 79.9

80/ 80
85.8/ 96.4

90/100
48.0/ 48.0
60/60

48.0/ 48.0
60/60

48.9/ 52.5
60/60

63.2/ 69.1

70/ 70
76.3/ 84.1

80/ 90
90.6/100.6

100/110
43.7/ 43.7
50/50

43.7/ 43.7
50/50

45.9/ 50.1
50/60

60.3/ 66.7

70/ 70
73.3/ 81.7

80/ 90
87.6/ 98.3

90/100
49.7/ 49.7
60/60

49.7/ 49.7
60/60

50.7/ 54.3
60/60

65.1/ 70.9

70/ 80
78.1/ 85.9

80/ 90
92.4/102.5

100/110
19.8
25

19.8
25

25.4
30

29.1
30

42.7
45

46.4
50

22.5
25

22.5
25

27.5
30

31.2
35

44.8
45

48.5
50

20.6
25

20.6
25

26.2
30

29.9
30

43.5
45

47.2
50

23.3
30

23.3
30

28.3
30

32.0
35

45.6
50

49.3
50

MCA

Electrical data 50HJ (cont)


COBRA ENERGY RECOVERY UNITS 50HJ004-007 UNITS WITH 62AQ100
UNIT
50HJ

NOMINAL
V-PH-Hz

IFM
TYPE

208/230-1-60

CONV
OUTLET

62AQ
FLA

NO

15.1

YES

15.1

NO

15.1

YES

15.1

NO

15.1

YES

15.1

NO

15.1

YES

15.1

NO

15.1

YES

15.1

NO

15.1

YES

15.1

NO

15.1

YES

15.1

NO

15.1

YES

15.1

STD

STD

208/230-3-60

004
HIGH STATIC

STD

460-3-60

HIGH STATIC

50HJ

208/230-1-60

STD

005
STD

208/230-3-60

HIGH STATIC

See legend and notes on page 233.

232

HEATER
CRHEATER
---A00

HEAT

NONE
001
002
003
004
002+002
NONE
001
002
003
004
002+002
NONE
001
002
003
004
005
NONE
001
002
003
004
005
NONE
001
002
003
004
005
NONE
001
002
003
004
005
NONE
006
007
008
009
NONE
006
007
008
009
NONE
006
007
008
009
NONE
006
007
008
009
NONE
001
003
002+002
003+003
004+004
NONE
001
003
002+002
003+003
004+004
NONE
002
003
005
004+004
NONE
002
003
005
004+004
NONE
002
003
005
004+004
NONE
002
003
005
004+004

/
15.9/18.3
23.5/27.1
31.4/36.3
37.9/43.8
46.9/54.2
/
15.9/18.3
23.5/27.1
31.4/36.3
37.9/43.8
46.9/54.2
/
9.2/10.6
13.6/15.6
18.1/20.9
21.9/25.3
33.4/38.5
/
9.2/10.6
13.6/15.6
18.1/20.9
21.9/25.3
33.4/38.5
/
9.2/10.6
13.6/15.6
18.1/20.9
21.9/25.3
33.4/38.5
/
9.2/10.6
13.6/15.6
18.1/20.9
21.9/25.3
33.4/38.5

7.2
10.6
13.8
16.8

7.2
10.6
13.8
16.8

7.2
10.6
13.8
16.8

7.2
10.6
13.8
16.8
/
15.9/18.3
31.4/36.3
46.9/54.2
62.8/72.5
75.8/87.5
/
15.9/18.3
31.4/36.3
46.9/54.2
62.8/72.5
75.8/87.5
/
13.6/15.6
18.1/20.9
33.4/38.5
43.8/50.5
/
13.6/15.6
18.1/20.9
33.4/38.5
43.8/50.5
/
13.6/15.6
18.1/20.9
33.4/38.5
43.8/50.5
/
13.6/15.6
18.1/20.9
33.4/38.5
43.8/50.5

FLA

POWER SUPPLY*
Fuse or
HACR Bkr
40.7/ 40.7
45/45
42.5/ 45.5
50/60
52.0/ 56.5

61.9/ 67.9

70.0/ 77.3

81.3/ 90.3

46.7/ 46.7
50/50
47.3/ 49.7
60/60
56.8/ 60.7

66.7/ 72.1

74.8/ 81.5

86.1/ 94.5

33.6/ 33.6
40/40
34.1/ 35.9
45/45
39.6/ 42.2
50/50
45.3/ 48.8
60/60
50.0/ 54.2
60/60
64.3/ 70.7

39.6/ 39.6
45/45
39.6/ 40.1
50/50
44.4/ 46.4
60/60
50.1/ 53.0
60/60
54.8/ 58.4

69.1/ 74.9

34.5/ 34.5
40/40
35.0/ 36.8
45/45
40.5/ 43.1
50/50
46.2/ 49.7
60/60
50.9/ 55.1
60/60
65.2/ 71.6

40.5/ 40.5
45/45
40.5/ 41.0
50/50
45.3/ 47.3
60/60
51.0/ 53.9
60/60
55.7/ 59.3

70.0/ 75.8

16.5
20.0
20.1
25.0
24.3
30.0
28.4
35.0
32.1
35.0
19.2
20.0
22.2
30.0
26.4
30.0
30.5
35.0
34.2
40.0
16.9
20.0
20.5
25.0
24.7
30.0
28.8
35.0
32.5
35.0
19.6
25.0
22.6
30.0
26.8
30.0
30.9
35.0
34.6
40.0
50.3/ 50.3
60/60
50.3/ 50.3
60/60
61.9/ 67.9

81.3/ 90.3

101.2/113.3

117.4/132.0

56.3/ 56.3
70/70
56.3/ 56.3

66.7/ 72.1

86.1/ 94.5

106.0/117.5

122.2/136.2

37.6/ 37.6
45/45
39.6/ 42.2
50/50
45.3/ 48.8
60/60
64.3/ 70.7

77.3/ 85.8

43.6/ 43.6
50/50
44.4/ 46.4
60/60
50.1/ 53.0
60/60
69.1/ 74.9

82.1/ 90.0

38.5/ 38.5
45/45
40.5/ 43.1
50/50
46.2/ 49.7
60/60
65.2/ 71.6

78.2/ 86.7

44.5/ 44.5
50/50
45.3/ 47.3
60/60
51.0/ 53.9
60/60
70.0/ 75.8

83.0/ 90.9

MCA

MOCP

SINGLE
POINT BOX
CRSINGLE---A00

60/ 70
70/ 70
80/ 80
90/100

70/ 70
70/ 80
80/ 90
90/100

70/ 80

60/ 70
80/ 80

70/ 80

70/ 70
80/ 80

70/ 70
90/100
110/125
125/150

70/ 70
70/ 80
90/100
110/125
125/150

70/ 80
80/ 90

80/ 80
90/ 90

70/ 80
80/ 90

80/ 80
90/100

004
004
004
005

004
004
005
005

002

002
002

002

002
003

025
025

025
025

025
025

025
025

004
005
005
005

004
004
005
005
005

002
003

002
003

002
003

003
003

DISCONNECT SIZE
FLA

LRA

42/ 42
42/ 44
50/ 54
59/ 65
67/ 73
77/ 85
48/ 48
48/ 49
56/ 59
65/ 70
72/ 78
82/ 90
36/ 36
36/ 36
39/ 41
44/ 47
48/ 52
61/ 67
41/ 41
41/ 41
44/ 46
49/ 52
54/ 57
67/ 72
37/ 37
37/ 37
40/ 42
45/ 48
49/ 53
62/ 68
42/ 42
42/ 42
45/ 47
50/ 53
55/ 58
68/ 73
18
18
18
27
31
23
23
23
32
35
18
18
18
28
31
24
24
24
32
36
51/ 51
51/ 51
59/ 65
77/ 85
95/106
110/124
57/ 57
57/ 57
65/ 70
82/ 90
101/111
116/128
39/ 39
39/ 41
44/ 47
61/ 67
73/ 81
45/ 45
45/ 46
49/ 52
67/ 72
79/ 86
40/ 40
40/ 42
45/ 48
62/ 68
74/ 82
46/ 46
46/ 47
50/ 53
68/ 73
80/ 87

161/161
161/161
161/161
161/161
161/161
161/161
166/166
166/166
166/166
166/166
166/166
166/166
150/150
150/150
150/150
150/150
150/150
150/150
155/155
155/155
155/155
155/155
155/155
155/155
180/180
180/180
180/180
180/180
180/180
180/180
184/184
184/184
184/184
184/184
184/184
184/184
76
76
77
80
83
80
81
81
82
85
90
90
91
94
97
95
95
95
96
99
199/199
199/199
199/199
199/199
199/199
199/199
204/204
204/204
204/204
204/204
204/204
204/204
166/166
166/166
166/166
166/166
166/166
171/171
171/171
171/171
171/171
171/171
196/196
196/196
196/196
196/196
196/196
200/200
200/200
200/200
200/200
200/200

COBRA ENERGY RECOVERY UNITS 50HJ004-007 UNITS WITH 62AQ100 (cont)


UNIT
50HJ

NOMINAL
V-PH-Hz

IFM
TYPE

CONV
OUTLET

62AQ
FLA

NO

15.1

YES

15.1

NO

15.1

YES

15.1

NO

15.1

YES

15.1

NO

15.1

YES

15.1

NO

15.1

YES

15.1

STD

005
(cont)

460-3-60

HIGH STATIC

208/230-1-60

006

STD

STD

208/230-3-60

HIGH STATIC

FLA
HACR
IFM
LRA
MCA
MOCP
NEC
UL

HEATER
CRHEATER
---A00

HEAT

NONE
006
008
009
008+008
NONE
006
008
009
008+008
NONE
006
008
009
008+008
NONE
006
008
009
008+008
NONE
002
003
002+002
003+003
004+004
NONE
002
003
002+002
003+003
004+004
NONE
002
004
005
004+004
004+005
NONE
002
004
005
004+004
004+005
NONE
002
004
005
004+004
004+005
NONE
002
004
005
004+004
004+005

7.2
13.8
16.8
27.7

7.2
13.8
16.8
27.7

7.2
13.8
16.8
27.7

7.2
13.8
16.8
27.7
/
23.5/27.1
31.4/36.3
46.9/54.2
62.8/72.5
75.8/87.5
/
23.5/27.1
31.4/36.3
46.9/54.2
62.8/72.5
75.8/87.5
/
13.6/15.6
21.9/25.3
33.4/38.5
43.8/50.5
55.2/63.8
/
13.6/15.6
21.9/25.3
33.4/38.5
43.8/50.5
55.2/63.8
/
13.6/15.6
21.9/25.3
33.4/38.5
43.8/50.5
55.2/63.8
/
13.6/15.6
21.9/25.3
33.4/38.5
43.8/50.5
55.2/63.8

FLA

LEGEND
Full Load Amps
Heating, Air Conditioning and Refrigeration
Indoor (Evaporator) Fan Motor
Locked Rotor Amps
Minimum Circuit Amps
Maximum Overcurrent Protection
National Electrical Code
Underwriters Laboratories

*Used to determine minimum disconnect per NEC.

= 100 x

max voltage deviation from average voltage


average voltage

MOCP

SINGLE
POINT BOX
CRSINGLE---A00

70/ 70
70/ 80
90/100
110/125
125/150

80/ 80
80/ 80
90/100
110/125
150/150

70/ 80
80/ 90
100/110

70/ 70
80/ 80
90/100
100/110

60/ 70
70/ 80
80/ 90
100/110

70/ 70
80/ 80
90/100
100/110

025
025
025

025
025
025

025
025
025

025
025
025

004
004
005
005
005

004
005
005
005
005

002
003
003

002
003
003
003

002
002
003
003

002
003
003
003

DISCONNECT SIZE
FLA

LRA

19
19
19
31
43
25
25
25
35
48
19
19
19
31
43
25
25
25
36
48
62/ 62
62/ 62
64/ 69
81/ 90
100/111
115/128
68/ 68
68/ 68
69/ 74
87/ 95
105/116
120/133
46/ 46
46/ 46
49/ 53
62/ 68
74/ 82
88/ 97
51/ 51
51/ 51
55/ 58
68/ 73
80/ 87
93/102
48/ 48
48/ 48
51/ 55
64/ 70
76/ 84
90/ 99
53/ 53
53/ 53
57/ 60
70/ 75
82/ 89
95/104

83
84
84
84
94
88
88
88
88
96
97
98
98
98
108
102
103
103
103
110
276/276
276/276
276/276
276/276
276/276
276/276
281/281
281/281
281/281
281/281
281/281
281/281
228/228
228/228
228/228
228/228
228/228
228/228
233/233
233/233
233/233
233/233
233/233
233/233
247/247
247/247
247/247
247/247
247/247
247/247
252/252
252/252
252/252
252/252
252/252
252/252

Example: Supply voltage is 460-3-60.


AB = 452 v
BC = 464 v
AC = 455 v
Average Voltage =
=

452 + 464 + 455


3
1371
3

= 457
Determine maximum deviation from average voltage.
(AB) 457 452 = 5 v
(BC) 464 457 = 7 v
(AC) 457 455 = 2 v
Maximum deviation is 7 v.
Determine percent of voltage imbalance.
7
% Voltage Imbalance = 100 x
457
= 1.53%
This amount of phase imbalance is satisfactory as it is below the maximum allowable
2%.
IMPORTANT: If the supply voltage phase imbalance is more than 2%, contact your
local electric utility company immediately.

233

50HJ

NOTES:
1. In compliance with NEC requirements for multimotor and combination load equipment (refer to NEC Articles 430 and 440), the overcurrent protective device for the
unit shall be fuse or HACR breaker. UL, Canada units may be fuse or circuit breaker.
2. Unbalanced 3-Phase Supply Voltage
Never operate a motor where a phase imbalance in supply voltage is greater than
2%. Use the following formula to determine the percent of voltage imbalance.

POWER SUPPLY*
Fuse or
HACR Bkr
18.2
20
20.1
25
28.4
35
32.1
30
45.6
50
20.9
25
22.2
30
30.5
35
34.2
40
47.7
50
18.6
25
20.5
25
28.8
35
32.5
35
46.0
50
21.3
25
22.6
30
30.9
35
34.6
40
48.1
50
61.4/ 61.4
70/70
61.4/ 61.4

65.8/ 71.8

85.2/ 94.2

105.1/117.2

121.3/135.9

67.4/ 67.4
80/80
67.4/ 67.4

70.6/ 76.0

90.0/ 98.4

109.9/121.4

126.1/140.1

44.0/ 44.0
50/50
44.0/ 44.0
50/50
50.9/ 55.1
60/60
65.2/ 71.6

78.2/ 86.7

92.6/103.2

50.0/ 50.0
60/60
50.0/ 50.0
60/60
55.7/ 59.3

70.0/ 75.8

83.0/ 90.9

97.4/107.4

45.7/ 45.7
60/60
45.7/ 45.7
60/60
52.6/ 56.8

66.9/ 73.3

79.9/ 88.4

94.3/104.9

51.7/ 51.7
60/60
51.7/ 51.7
60/60
57.4/ 61.0

71.7/ 77.5

84.7/ 92.6

99.1/109.1

MCA

Electrical data 50HJ (cont)


COBRA ENERGY RECOVERY UNITS 50HJ004-007 UNITS WITH 62AQ100 (cont)
UNIT
50HJ

NOMINAL
V-PH-Hz

IFM
TYPE

CONV
OUTLET

62AQ
FLA

NO

15.1

YES

15.1

NO

15.1

YES

15.1

NO

15.1

YES

15.1

NO

15.1

YES

15.1

NO

15.1

YES

15.1

NO

15.1

YES

15.1

STD

006
(cont)

460-3-60

HIGH STATIC

STD

208/230-3-60

HIGH STATIC

007

STD

460-3-60

50HJ

HIGH STATIC

FLA
HACR
IFM
LRA
MCA
MOCP
NEC
UL

HEATER
CRHEATER
---A00

HEAT

NONE
006
008
009
008+008
008+009
NONE
006
008
009
008+008
008+009
NONE
006
008
009
008+008
008+009
NONE
006
008
009
008+008
008+009
NONE
002
004
005
004+004
004+005
NONE
002
004
005
004+004
004+005
NONE
002
004
005
004+004
004+005
NONE
002
004
005
004+004
004+005
NONE
006
008
009
008+008
008+009
NONE
006
008
009
008+008
008+009
NONE
006
008
009
008+008
008+009
NONE
006
008
009
008+008
008+009

7.2
13.8
16.8
27.7
30.7

7.2
13.8
16.8
27.7
30.7

7.2
13.8
16.8
27.7
30.7

7.2
13.8
16.8
27.7
30.7
/
13.6/15.6
21.9/25.3
33.4/38.5
43.8/50.5
55.2/63.8
/
13.6/15.6
21.9/25.3
33.4/38.5
43.8/50.5
55.2/63.8
/
13.6/15.6
21.9/25.3
33.4/38.5
43.8/50.5
55.2/63.8
/
13.6/15.6
21.9/25.3
33.4/38.5
43.8/50.5
55.2/63.8

7.2
13.8
16.8
27.7
30.7

7.2
13.8
16.8
27.7
30.7

7.2
13.8
16.8
27.7
30.7

7.2
13.8
16.8
27.7
30.7

FLA

LEGEND
Full Load Amps
Heating, Air Conditioning and Refrigeration
Indoor (Evaporator) Fan Motor
Locked Rotor Amps
Minimum Circuit Amps
Maximum Overcurrent Protection
National Electrical Code
Underwriters Laboratories

*Used to determine minimum disconnect per NEC.


NOTES:
1. In compliance with NEC requirements for multimotor and combination load equipment (refer
to NEC Articles 430 and 440), the overcurrent protective device for the unit shall be fuse or
HACR breaker. UL, Canada units may be fuse or circuit breaker.
2. Unbalanced 3-Phase Supply Voltage
Never operate a motor where a phase imbalance in supply voltage is greater than 2%. Use
the following formula to determine the percent of voltage imbalance.
= 100 x

max voltage deviation from average voltage


average voltage

POWER SUPPLY*
Fuse or
HACR Bkr
22.2
25
22.2
25
28.8
35
32.5
35
46.0
50
49.8
50
24.9
30
24.9
30
30.9
35
34.6
40
48.1
50
51.9
60
23.0
30
23.0
30
29.6
35
33.3
35
46.8
50
50.6
60
25.7
30
25.7
30
31.7
35
35.4
40
48.9
50
52.7
60
47.9/ 47.9
60/60
47.9/ 47.9
60/60
50.9/ 55.1
60/60
65.2/ 71.6

78.2/ 86.7

92.6/103.2

53.9/ 53.9
60/60
53.9/ 53.9
60/60
55.7/ 59.3

70.0/ 75.8

83.0/ 90.9

97.4/107.4

49.6/ 49.6
60/60
49.6/ 49.6
60/60
52.6/ 56.8

66.9/ 73.3

79.9/ 88.4

94.3/104.9

55.6/ 55.6
60/60
55.6/ 55.6
60/60
57.4/ 61.0

71.7/ 77.5

84.7/ 92.6

99.1/109.1

22.8
30
22.8
30
28.8
35
32.5
35
46.0
50
49.8
50
25.5
30
25.5
30
30.9
35
34.6
40
48.1
50
51.9
60
23.6
30
23.6
30
29.6
35
33.3
35
46.8
50
50.6
60
26.3
30
26.3
30
31.7
35
35.4
40
48.9
50
52.7
60
MCA

MOCP

SINGLE
POINT BOX
CRSINGLE---A00

70/ 80
80/ 90
100/110

70/ 70
80/ 80
90/100
100/110

60/ 70
70/ 80
80/ 90
100/110

70/ 70
80/ 80
90/100
100/110

025
025
025
025

025
025
025
025

025
025
025
025

025
025
025
025

002
003
003

002
003
003
003

002
002
003
003

002
003
003
003

025
025
025
025

025
025
025
025

025
025
025
025

025
025
025
025

DISCONNECT SIZE
FLA

LRA

23
23
23
31
43
47
28
28
28
36
48
52
24
24
24
32
44
48
29
29
29
37
49
53
49/ 49
49/ 49
49/ 53
62/ 68
74/ 82
88/ 97
55/ 55
55/ 55
55/ 58
68/ 73
80/ 87
93/102
51/ 51
51/ 51
51/ 55
64/ 70
76/ 84
90/ 99
57/ 57
57/ 57
57/ 60
70/ 75
82/ 89
95/104
23
23
23
31
43
47
29
29
29
36
48
52
24
24
24
32
44
48
30
30
30
37
49
53

114
114
114
114
114
114
119
119
119
119
119
119
123
124
124
124
124
124
128
129
129
129
129
129
260/260
260/260
260/260
260/260
260/260
260/260
265/265
265/265
265/265
265/265
265/265
265/265
279/279
279/279
279/279
279/279
279/279
279/279
284/284
284/284
284/284
284/284
284/284
284/284
127
127
127
127
127
127
131
132
132
132
132
132
136
137
137
137
137
137
141
141
141
141
141
141

Example: Supply voltage is 460-3-60.


AB = 452 v
BC = 464 v
AC = 455 v
Average Voltage =

452 + 464 + 455

1371
=
3
= 457
Determine maximum deviation from average voltage.
(AB) 457 452 = 5 v
(BC) 464 457 = 7 v
(AC) 457 455 = 2 v
Maximum deviation is 7 v.
Determine percent of voltage imbalance.
7
% Voltage Imbalance
= 100 x 457
= 1.53%
This amount of phase imbalance is satisfactory as it is below the maximum allowable 2%.
IMPORTANT: If the supply voltage phase imbalance is more than 2%, contact your local
electric utility company immediately.

234

COBRA ENERGY RECOVERY UNITS 50HJ008-014 UNITS WITH 62AQ200


UNIT
50HJ

NOMINAL
V-PH-Hz

IFM
TYPE

CONV
OUTLET

62AQ
FLA

21.9

YES

21.9

NO

21.9

YES

21.9

NO

10.2

YES

10.2

NO

10.2

YES

10.2

NO

21.9

YES

21.9

NO

21.9

YES

21.9

NO

10.2

YES

10.2

NO

10.2

YES

10.2

STD

208/230-3-60

HIGH STATIC

008

STD

460-3-60

HIGH STATIC

STD

208/230-3-60

HIGH STATIC

009

STD

460-3-60

HIGH STATIC

HEAT
FLA
/
21.7/ 25.0
33.4/ 38.5
51.7/ 59.7
66.7/ 77.0
88.4/102.0
/
21.7/ 25.0
33.4/ 38.5
51.7/ 59.7
66.7/ 77.0
88.4/102.0
/
21.7/ 25.0
33.4/ 38.5
51.7/ 59.7
66.7/ 77.0
88.4/102.0
/
21.7/ 25.0
33.4/ 38.5
51.7/ 59.7
66.7/ 77.0
88.4/102.0

16.7
19.8
33.4
39.7
50.2

16.7
19.8
33.4
39.7
50.2

16.7
19.8
33.4
39.7
50.2

16.7
19.8
33.4
39.7
50.2
/
21.7/ 25.0
33.4/ 38.5
51.7/ 59.7
66.7/ 77.0
88.4/102.0
/
21.7/ 25.0
33.4/ 38.5
51.7/ 59.7
66.7/ 77.0
88.4/102.0
/
21.7/ 25.0
33.4/ 38.5
51.7/ 59.7
66.7/ 77.0
88.4/102.0
/
21.7/ 25.0
33.4/ 38.5
51.7/ 59.7
66.7/ 77.0
88.4/102.0

16.7
19.8
33.4
39.7
50.2

16.7
19.8
33.4
39.7
50.2

16.7
19.8
33.4
39.7
50.2

16.7
19.8
33.4
39.7
50.2

POWER SUPPLY*
Fuse or
HACR Bkr
60.1/ 60.1
70/70
60.1/ 64.0

74.5/ 80.9

97.4/107.4

116.2/129.0

143.3/160.3

66.1/ 66.1
70/70
66.1/ 68.2

79.3/ 85.1

102.2/111.6

121.0/133.2

148.1/164.5

63.2/ 63.2
70/70
63.2/ 67.1

77.6/ 84.0

100.5/110.5

119.3/132.1

146.4/163.4

69.2/ 69.2
80/80
69.2/ 71.3

82.4/ 88.2

105.3/114.7

124.1/136.3

151.2/167.6

29.4
35.0
36.1
40.0
40.0
45.0
57.0
60.0
64.8

77.9

32.1
35.0
38.2
45.0
42.1
45.0
59.1
60.0
66.9

80.0

30.8
35.0
37.5
40.0
41.4
45.0
58.4
60.0
66.2

79.3

33.5
35.0
39.6
45.0
43.5
45.0
60.5

68.3

81.4

62.1/ 62.1
70/70
62.1/ 64.0

74.5/ 80.9

97.4/107.4

116.2/129.0

143.3/160.3

68.1/ 68.1
70/70
68.1/ 68.2

79.3/ 85.1

102.2/111.6

121.0/133.2

148.1/164.5

65.2/ 65.2
70/70
65.2/ 67.1

77.6/ 84.0

100.5/110.5

119.3/132.1

146.4/163.4

71.2/ 71.2
80/80
71.2/ 71.3

82.4 /88.2

105.3/114.7

124.1/136.3

151.2/167.6

31.7
35.0
36.1
40.0
40.0
45.0
57.0
60.0
64.8

77.9

34.4
40.0
38.2
45.0
42.1
45.0
59.1
60.0
66.9

80.0

33.1
35.0
37.5
40.0
41.4
45.0
58.4
60.0
66.2

79.3

35.8
40.0
39.6
45.0
43.5
45.0
60.5

68.3

81.4

MCA

MOCP
/
70/ 80
80/ 90
100/110
125/150
150/175
/
80/ 80
90/ 90
110/125
125/150
150/175
/
80/ 80
90/ 90
110/125
125/150
150/175
/
80/ 80
90/100
110/125
125/150
175/175

70.0
80.0

70.0
80.0

70.0
80.0

70.0
70.0
90.0

70/ 80
80/ 90
100/110
125/150
150/175

80/ 80
90/ 90
110/125
125/150
150/175
/
80/ 80
90/ 90
110/125
125/150
150/175
/
80/ 80
90/100
110/125
125/150
175/175

70.0
80.0

70.0
80.0

70.0
80.0

70.0
70.0
90.0

SINGLE
POINT BOX
CRSINGLE---A00

007
007
009
009
009

007
009
009
009
009

007
009
009
009
009

007
009
009
009
009

006
006
006
008
010

006
006
006
008
010

006
006
006
008
010

006
006
008
008
010

012
012
015
015
015

012
015
015
015
015

012
015
015
015
015

012
015
015
015
015

011
011
011
014
016

011
011
011
014
016

011
011
011
014
016

011
011
014
014
016

DISCONNECT SIZE
FLA

LRA

66/ 66
66/ 66
72/ 78
93/102
111/122
135/151
71/ 71
71/ 71
78/ 83
99/107
116/127
141/156
69/ 69
69/ 69
76/ 82
97/106
114/126
139/155
75/ 75
75/ 75
81/ 86
102/111
120/131
145/160
32.0
35.0
38.0
54.0
61.0
73.0
34.0
37.0
41.0
57.0
64.0
76.0
34.0
36.0
40.0
56.0
63.0
75.0
36.0
39.0
42.0
58.0
65.0
77.0
68/ 68
68/ 68
72/ 78
93/102
111/122
135/151
73/ 73
73/ 73
78/ 83
99/107
116/127
141/156
71/ 71
71/ 71
76/ 82
97/106
114/126
139/155
77/ 77
77/ 77
81/ 86
102/111
120/131
145/160
34.0
35.0
38.0
54.0
61.0
73.0
37.0
37.0
41.0
57.0
64.0
76.0
36.0
36.0
40.0
56.0
63.0
75.0
38.0
39.0
42.0
58.0
65.0
77.0

366/366
366/366
366/366
366/366
366/366
366/366
371/371
371/371
371/371
371/371
371/371
371/371
391/391
391/391
391/391
391/391
391/391
391/391
395/395
395/395
395/395
395/395
395/395
395/395
184.0
184.0
184.0
184.0
184.0
184.0
186.0
186.0
186.0
186.0
186.0
186.0
196.0
197.0
197.0
197.0
197.0
197.0
198.0
199.0
199.0
199.0
199.0
199.0
400/400
400/400
400/400
400/400
400/400
400/400
405/405
405/405
405/405
405/405
405/405
405/405
425/425
425/425
425/425
425/425
425/425
425/425
429/429
429/429
429/429
429/429
429/429
429/429
206.0
206.0
206.0
206.0
206.0
206.0
208.0
208.0
208.0
208.0
208.0
208.0
218.0
219.0
219.0
219.0
219.0
219.0
220.0
221.0
221.0
221.0
221.0
221.0

235

50HJ

NO

HEATER
CRHEATER
---A00
NONE
017
010
011
012
012+017
NONE
017
010
011
012
012+017
NONE
017
010
011
012
012+017
NONE
017
010
011
012
012+017
NONE
016
013
014
015
014+016
NONE
016
013
014
015
014+016
NONE
016
013
014
015
014+016
NONE
016
013
014
015
014+016
NONE
017
010
011
012
012+017
NONE
017
010
011
012
012+017
NONE
017
010
011
012
012+017
NONE
017
010
011
012
012+017
NONE
016
013
014
015
014+016
NONE
016
013
014
015
014+016
NONE
016
013
014
015
014+016
NONE
016
013
014
015
014+016

Electrical data 50HJ (cont)


COBRA ENERGY RECOVERY UNITS 50HJ008-014 UNITS WITH 62AQ200 (cont)
UNIT
50HJ

NOMINAL
V-PH-Hz

IFM
TYPE

CONV
OUTLET

62AQ
FLA

NO

21.9

YES

21.9

NO

21.9

YES

21.9

NO

10.2

YES

10.2

NO

10.2

YES

10.2

NO

21.9

YES

21.9

NO

10.2

YES

10.2

STD

208/230-3-60

HIGH STATIC

012

STD

460-3-60

HIGH STATIC

208/230-3-60

STD

014

50HJ

460-3-60

FLA
HACR
IFM
LRA
MCA
MOCP
NEC
UL

STD

HEATER
CRHEATER
---A00

HEAT

NONE
017
010
012
012+017
010+012
NONE
017
010
012
012+017
010+012
NONE
017
010
012
012+017
010+012
NONE
017
010
012
012+017
010+012
NONE
016
013
015
014+016
013+015
NONE
016
013
015
014+016
013+015
NONE
016
013
015
014+016
013+015
NONE
016
013
015
014+016
013+015
NONE
017
010
012
012+017
010+012
NONE
017
010
012
012+017
010+012
NONE
016
013
015
014+016
013+015
NONE
016
013
015
014+016
013+015

/
21.7/ 25.0
33.4/ 38.5
66.7/ 77.0
88.4/102.0
104.2/120.3
/
21.7/ 25.0
33.4/ 38.5
66.7/ 77.0
88.4/102.0
104.2/120.3
/
21.7/ 25.0
33.4/ 38.5
66.7/ 77.0
88.4/102.0
104.2/120.3
/
21.7/ 25.0
33.4/ 38.5
66.7/ 77.0
88.4/102.0
104.2/120.3

16.7
19.8
39.7
50.2
60.1

16.7
19.8
39.7
50.2
60.1

16.7
19.8
39.7
50.2
60.1

16.7
19.8
39.7
50.2
60.1
/
21.7/ 25.0
33.4/ 38.5
66.7/ 77.0
88.4/102.0
104.2/120.3
/
21.7/ 25.0
33.4/ 38.5
66.7/ 77.0
88.4/102.0
104.2/120.3

16.7
19.8
39.7
50.2
60.1

16.7
19.8
39.7
50.2
60.1

FLA

LEGEND
Full Load Amps
Heating, Air Conditioning and Refrigeration
Indoor (Evaporator) Fan Motor
Locked Rotor Amps
Minimum Circuit Amps
Maximum Overcurrent Protection
National Electrical Code
Underwriters Laboratories

*Used to determine minimum disconnect per NEC.


NOTES:
1. In compliance with NEC requirements for multimotor and combination load equipment (refer
to NEC Articles 430 and 440), the overcurrent protective device for the unit shall be fuse or
HACR breaker. UL, Canada units may be fuse or circuit breaker.
2. Unbalanced 3-Phase Supply Voltage
Never operate a motor where a phase imbalance in supply voltage is greater than 2%. Use
the following formula to determine the percent of voltage imbalance.
max voltage deviation from average voltage
= 100 x
average voltage

POWER SUPPLY*
Fuse or
HACR Bkr
74.9/ 74.9

74.9/ 74.9

77.6/ 84.0

119.3/132.1

146.4/163.4

166.2/156.2

80.9/ 80.9

80.9/ 80.9

82.4/ 88.2

124.1/136.3

151.2/167.6

171.0/160.4

79.3/ 79.3

79.3/ 79.3

82.3/ 88.8

124.0/136.9

151.1/168.2

170.9/160.9

85.3/ 85.3

85.3/ 85.3

87.1/ 93.0

128.8/141.1

155.9/172.4

175.7/165.1

35.1
40.0
37.5
40.0
41.4
45.0
66.2

79.3

76.7

37.8
40.0
39.6
45.0
43.5
45.0
68.3

81.4

78.8

37.7
40.0
40.3
45.0
44.3
50.0
69.1

82.1

79.6

40.4
45.0
42.4
50.0
46.4
50.0
71.2

84.2

81.7

82.5/ 82.5

82.5/ 82.5

82.3/ 88.8

124.0/136.9

151.1/168.2

170.9/160.9

88.5/ 88.5

88.5/ 88.5

87.1/ 93.0

128.8/141.1

155.9/172.4

175.7/165.1

39.3
45.0
40.3
45.0
44.3
50.0
69.1

82.1

79.6

42.0
45.0
42.4
50.0
46.4
50.0
71.2

84.2

81.7

MCA

MOCP

SINGLE
POINT BOX
CRSINGLE---A00

80/ 80
80/ 80
90/ 90
125/150
150/175
175/175
90/ 90
90/ 90
90/100
125/150
175/175
175/175
90/ 90
90/ 90
90/100
125/150
175/175
175/200
90/ 90
90/ 90
100/100
150/150
175/175
200/200

70.0
80.0
90.0

70.0
90.0
90.0

70.0
90.0
90.0

80.0
90.0
90.0
90/ 90
90/ 90
90/100
125/150
175/175
175/200
100/100
100/100
100/100
150/150
175/175
200/200

70.0
90.0
90.0

80.0
90.0
90.0

011
011
014
016
016

011
011
014
016
016

011
011
014
016
016

011
011
014
016
016

011
011
016
016
016

011
011
016
016
016

DISCONNECT SIZE
FLA

LRA

81/ 81
81/ 81
81/ 82
114/126
139/155
157/176
87/ 87
87/ 87
87/ 87
120/131
145/160
163/181
86/ 86
86/ 86
86/ 87
119/131
144/160
162/181
92/ 92
92/ 92
92/ 92
125/136
150/165
168/186
38.0
38.0
40.0
63.0
75.0
86.0
40.0
40.0
42.0
65.0
77.0
89.0
41.0
41.0
43.0
66.0
78.0
89.0
43.0
43.0
45.0
68.0
80.0
92.0
89/ 89
89/ 89
89/ 89
119/131
144/160
162/181
95/ 95
95/ 95
95/ 95
125/136
150/165
168/186
43.0
43.0
43.0
66.0
78.0
89.0
45.0
45.0
45.0
68.0
80.0
92.0

465/465
465/465
465/465
465/465
465/465
465/465
469/469
469/469
469/469
469/469
469/469
469/469
488/488
488/488
488/488
488/488
488/488
488/488
493/493
493/493
493/493
493/493
493/493
493/493
233.0
234.0
234.0
234.0
234.0
234.0
235.0
236.0
236.0
236.0
236.0
236.0
245.0
245.0
245.0
245.0
245.0
245.0
247.0
247.0
247.0
247.0
247.0
247.0
550/550
550/550
550/550
550/550
550/550
550/550
555/555
555/555
555/555
555/555
555/555
555/555
260.0
260.0
260.0
260.0
260.0
260.0
262.0
262.0
262.0
262.0
262.0
262.0

Example: Supply voltage is 460-3-60.


AB = 452 v
BC = 464 v
AC = 455 v
Average Voltage =
=

452 + 464 + 455


3
1371
3

= 457
Determine maximum deviation from average voltage.
(AB) 457 452 = 5 v
(BC) 464 457 = 7 v
(AC) 457 455 = 2 v
Maximum deviation is 7 v.
Determine percent of voltage imbalance.
7
% Voltage Imbalance = 100 x
457
= 1.53%
This amount of phase imbalance is satisfactory as it is below the maximum allowable 2%.
IMPORTANT: If the supply voltage phase imbalance is more than 2%, contact your local
electric utility company immediately.

236

COBRA ENERGY RECOVERY UNITS 50HJ008-014 UNITS WITH 62AQ300


UNIT
50HJ

NOMINAL
V-PH-Hz

IFM
TYPE

CONV
OUTLET

62AQ
FLA

29.8

YES

29.8

NO

29.8

YES

29.8

NO

15.8

YES

15.8

NO

15.8

YES

15.8

NO

29.8

YES

29.8

NO

29.8

YES

29.8

NO

15.8

YES

15.8

NO

15.8

YES

15.8

STD

208/230-3-60

HIGH STATIC

008

STD

460-3-60

HIGH STATIC

STD

208/230-3-60

HIGH STATIC

009

STD

460-3-60

HIGH STATIC

HEAT

NONE
017
010
011
012
012+017
NONE
017
010
011
012
012+017
NONE
017
010
011
012
012+017
NONE
017
010
011
012
012+017
NONE
016
013
014
015
014+016
NONE
016
013
014
015
014+016
NONE
016
013
014
015
014+016
NONE
016
013
014
015
014+016
NONE
017
010
011
012
012+017
NONE
017
010
011
012
012+017
NONE
017
010
011
012
012+017
NONE
017
010
011
012
012+017
NONE
016
013
014
015
014+016
NONE
016
013
014
015
014+016
NONE
016
013
014
015
014+016
NONE
016
013
014
015
014+016

/
21.7/ 25.0
33.4/ 38.5
51.7/ 59.7
66.7/ 77.0
88.4/102.0
/
21.7/ 25.0
33.4/ 38.5
51.7/ 59.7
66.7/ 77.0
88.4/102.0
/
21.7/ 25.0
33.4/ 38.5
51.7/ 59.7
66.7/ 77.0
88.4/102.0
/
21.7/ 25.0
33.4/ 38.5
51.7/ 59.7
66.7/ 77.0
88.4/102.0

16.7
19.8
33.4
39.7
50.2

16.7
19.8
33.4
39.7
50.2

16.7
19.8
33.4
39.7
50.2

16.7
19.8
33.4
39.7
50.2
/
21.7/ 25.0
33.4/ 38.5
51.7/ 59.7
66.7/ 77.0
88.4/102.0
/
21.7/ 25.0
33.4/ 38.5
51.7/ 59.7
66.7/ 77.0
88.4/102.0
/
21.7/ 25.0
33.4/ 38.5
51.7/ 59.7
66.7/ 77.0
88.4/102.0
/
21.7/ 25.0
33.4/ 38.5
51.7/ 59.7
66.7/ 77.0
88.4/102.0

16.7
19.8
33.4
39.7
50.2

16.7
19.8
33.4
39.7
50.2

16.7
19.8
33.4
39.7
50.2

16.7
19.8
33.4
39.7
50.2

FLA

POWER SUPPLY*
Fuse or
HACR Bkr
68.0/ 68.0
80/80
68.7/ 72.9

83.3/ 89.7

106.2/116.2

125.0/137.8

152.1/169.1

74.0/ 74.0
80/80
74.0/ 77.1

88.1/ 93.9

111.0/120.4

129.8/142.0

156.9/173.3

71.1/ 71.1
80/80
71.8/ 76.0

86.4/ 92.8

109.3/119.3

128.1/140.9

155.2/172.2

77.1/ 77.1
80/80
77.1/ 80.2

91.2/ 97.0

114.1/123.5

132.9/145.1

160.0/176.4

35.0
40.0
44.4
60.0
48.3
60.0
65.3

73.1

86.2

37.7
40.0
46.5
60.0
50.4
60.0
67.4

75.2

88.3

36.4
40.0
45.8
60.0
49.7
60.0
66.7

74.5

87.6

39.1
45.0
47.9
60.0
51.8
60.0
68.8

76.6

89.7

70.0/ 70.0
80/80
70.0/ 72.9

83.3/ 89.7

106.2/116.2

125.0/137.8

152.1/169.1

76.0/ 76.0
80/80
76.0/ 77.1

88.1/ 93.9

111.0/120.4

129.8/142.0

156.9/173.3

73.1/ 73.1
80/80
73.1/ 76.0

86.4/ 92.8

109.3/119.3

128.1/140.9

155.2/172.2

79.1/ 79.1
80/80
79.1/ 80.2

91.2/ 97.0

114.1/123.5

132.9/145.1

160.0/176.4

37.3
40.0
44.4
60.0
48.3
60.0
65.3

73.1

86.2

40.0
45.0
46.5
60.0
50.4
60.0
67.4

75.2

88.3

38.7
45.0
45.8
60.0
49.7
60.0
66.7

74.5

87.6

41.4
45.0
47.9
60.0
51.8
60.0
68.8

76.6

89.7

MCA

MOCP

SINGLE
POINT BOX
CRSINGLE---A00

90/ 90
100/100
125/125
150/150
175/175

90/ 90
100/110
125/125
150/150
175/175

90/ 90
100/110
125/125
150/150
175/175

90/100
110/110
125/150
150/150
175/200

80.0
90.0
100.0

80.0
90.0
100.0

80.0
90.0
100.0

80.0
90.0
100.0

90/ 90
100/100
125/125
150/150
175/175

90/ 90
100/110
125/125
150/150
175/175

90/ 90
100/110
125/125
150/150
175/175

90/100
110/110
125/150
150/150
175/200

80.0
90.0
100.0

80.0
90.0
100.0

80.0
90.0
100.0

80.0
90.0
100.0

007
007
009
009
009

007
009
009
009
009

007
009
009
009
009

007
009
009
009
009

006
006
008
008
010

006
006
008
008
010

006
006
008
008
010

006
006
008
008
010

012
012
015
015
015

012
015
015
015
015

012
015
015
015
015

012
015
015
015
015

011
011
014
014
016

011
011
014
014
016

011
011
014
014
016

011
011
014
014
016

DISCONNECT SIZE
FLA

LRA

75/ 75
75/ 75
81/ 87
102/112
120/131
145/160
80/ 80
80/ 80
87/ 92
108/116
125/136
150/165
78/ 78
78/ 78
85/ 91
106/115
123/135
148/164
84/ 84
84/ 84
90/ 96
111/120
129/140
154/169
38.0
41.0
45.0
61.0
68.0
80.0
41.0
44.0
47.0
63.0
70.0
82.0
40.0
43.0
47.0
62.0
69.0
81.0
43.0
45.0
49.0
65.0
72.0
84.0
77/ 77
77/ 77
81/ 87
102/112
120/131
145/160
82/ 82
82/ 82
87/ 92
108/116
125/136
150/165
80/ 80
80/ 80
85/ 91
106/115
123/135
148/164
86/ 86
86/ 86
90/ 96
111/120
129/140
154/169
41.0
41.0
45.0
61.0
68.0
80.0
43.0
44.0
47.0
63.0
70.0
82.0
42.0
43.0
47.0
62.0
69.0
81.0
45.0
45.0
49.0
65.0
72.0
84.0

420/420
420/420
420/420
420/420
420/420
420/420
425/425
425/425
425/425
425/425
425/425
425/425
445/445
445/445
445/445
445/445
445/445
445/445
449/449
449/449
449/449
449/449
449/449
449/449
211.0
211.0
211.0
211.0
211.0
211.0
213.0
213.0
213.0
213.0
213.0
213.0
223.0
224.0
224.0
224.0
224.0
224.0
225.0
226.0
226.0
226.0
226.0
226.0
454/454
454/454
454/454
454/454
454/454
454/454
459/459
459/459
459/459
459/459
459/459
459/459
479/479
479/479
479/479
479/479
479/479
479/479
483/483
483/483
483/483
483/483
483/483
483/483
233.0
233.0
233.0
233.0
233.0
233.0
235.0
235.0
235.0
235.0
235.0
235.0
245.0
246.0
246.0
246.0
246.0
246.0
247.0
248.0
248.0
248.0
248.0
248.0

237

50HJ

NO

HEATER
CRHEATER
---A00

Electrical data 50HJ (cont)


COBRA ENERGY RECOVERY UNITS 50HJ008-014 UNITS WITH 62AQ300 (cont)
UNIT
50HJ

NOMINAL
V-PH-Hz

IFM
TYPE

CONV
OUTLET

62AQ
FLA

NO

29.8

YES

29.8

NO

29.8

YES

29.8

NO

15.8

YES

15.8

NO

15.8

YES

15.8

NO

29.8

YES

29.8

NO

15.8

YES

15.8

STD

208/230-3-60

HIGH STATIC

012

STD

460-3-60

HIGH STATIC

208/230-3-60

STD

014

50HJ

460-3-60

FLA
HACR
IFM
LRA
MCA
MOCP
NEC
UL

STD

HEATER
CRHEATER
---A00

HEAT

NONE
017
010
012
012+017
010+012
NONE
017
010
012
012+017
010+012
NONE
017
010
012
012+017
010+012
NONE
017
010
012
012+017
010+012
NONE
016
013
014
014+016
013+015
NONE
016
013
014
014+016
013+015
NONE
016
013
014
014+016
013+015
NONE
016
013
014
014+016
013+015
NONE
017
010
012
012+017
010+012
NONE
017
010
012
012+017
010+012
NONE
016
013
016
014+016
013+015
NONE
016
013
016
014+016
013+015

/
21.7/ 25.0
33.4/ 38.5
66.7/ 77.0
88.4/102.0
104.2/120.3
/
21.7/ 25.0
33.4/ 38.5
66.7/ 77.0
88.4/102.0
104.2/120.3
/
21.7/ 25.0
33.4/3 8.5
66.7/ 77.0
88.4/102.0
104.2/120.3
/
21.7/ 25.0
33.4/ 38.5
66.7/ 77.0
88.4/102.0
104.2/120.3

16.7
19.8
33.4
50.2
60.1

16.7
19.8
33.4
50.2
60.1

16.7
19.8
33.4
50.2
60.1

16.7
19.8
33.4
50.2
60.1
/
21.7/ 25.0
33.4/ 38.5
66.7/ 77.0
88.4/102.0
104.2/120.3
/
21.7/ 25.0
33.4/ 38.5
66.7/ 77.0
88.4/102.0
104.2/120.3

16.7
19.8
16.7
50.2
60.1

16.7
19.8
16.7
50.2
60.1

FLA

LEGEND
Full Load Amps
Heating, Air Conditioning and Refrigeration
Indoor (Evaporator) Fan Motor
Locked Rotor Amps
Minimum Circuit Amps
Maximum Overcurrent Protection
National Electrical Code
Underwriters Laboratories

*Used to determine minimum disconnect per NEC.


NOTES:
1. In compliance with NEC requirements for multimotor and combination load equipment (refer
to NEC Articles 430 and 440), the overcurrent protective device for the unit shall be fuse or
HACR breaker. UL, Canada units may be fuse or circuit breaker.
2. Unbalanced 3-Phase Supply Voltage
Never operate a motor where a phase imbalance in supply voltage is greater than 2%. Use
the following formula to determine the percent of voltage imbalance.
max voltage deviation from average voltage
= 100 x
average voltage

POWER SUPPLY*
FUSE OR
HACR BKR
82.8/ 82.8

82.8/ 82.8

86.4/ 92.8

128.1/140.9

155.2/172.2

175.0/165.0

88.8/ 88.8

88.8/ 88.8

91.2/ 97.0

132.9/145.1

160.0/176.4

179.8/169.2

87.2/ 87.2

87.2/ 87.2

90.8/ 97.2

132.5/145.3

159.6/176.6

179.4/169.4

93.2/ 93.2

93.2/ 93.2

95.6/101.4

137.3/149.5

164.4/180.8

184.2/173.6

40.7
45.0
45.8
60.0
49.7
60.0
66.7

87.6

85.0

43.4
45.0
47.9
60.0
51.8
60.0
68.8

89.7

87.1

43.3
50.0
48.4
60.0
52.3
60.0
69.3

90.2

87.6

46.0
50.0
50.5
60.0
54.4
60.0
71.4

92.3

89.7

90.4/ 90.4

90.4/ 90.4

90.8/ 97.2

132.5/145.3

159.6/176.6

179.4/169.4

96.4/ 96.4

96.4/ 96.4

95.6/101.4

137.3/149.5

164.4/180.8

184.2/173.6

44.9
50.0
48.4
60.0
52.3
60.0
48.4

90.2

87.6

47.6
50.0
50.5
60.0
54.4
60.0
50.5

92.3

89.7

MCA

MOCP

SINGLE
POINT BOX
CRSINGLE---A00

90/ 90
90/ 90
100/110
150/150
175/175
175/200
100/100
100/100
110/110
150/150
175/200
200/200
100/100
100/100
100/110
150/150
175/200
200/200
100/100
100/100
110/110
150/150
175/200
200/200

80.0
100.0
110.0

80.0
100.0
110.0

80.0
100.0
110.0

90.0
100.0
110.0
100/100
100/100
100/110
150/150
175/200
200/200
100/100
100/100
110/110
150/150
175/200
200/200

70.0
100.0
110.0

70.0
100.0
110.0

011
011
014
016
016

014
011
014
016
016

014
011
014
016
016

014
011
014
016
016

014
011
014
016
016

014
011
014
016
016

DISCONNECT SIZE
FLA

LRA

90/ 90
90/ 90
90/ 91
123/135
148/164
166/185
96/ 96
96/ 96
96/ 96
129/140
154/169
172/190
95/ 95
95/ 95
95/ 96
128/140
153/169
171/190
101/101
101/101
101/101
134/145
159/174
177/195
44.0
44.0
47.0
62.0
81.0
93.0
47.0
47.0
49.0
65.0
84.0
95.0
47.0
47.0
50.0
65.0
84.0
96.0
50.0
50.0
52.0
68.0
87.0
98.0
98/ 98
98/ 98
98/ 98
128/140
153/169
171/190
104/104
104/104
104/104
134/145
159/174
177/195
49.0
49.0
50.0
49.0
84.0
96.0
51.0
51.0
52.0
51.0
87.0
98.0

519/519
519/519
519/519
519/519
519/519
519/519
523/523
523/523
523/523
523/523
523/523
523/523
542/542
542/542
542/542
542/542
542/542
542/542
547/547
547/547
547/547
547/547
547/547
547/547
260.0
261.0
261.0
261.0
261.0
261.0
262.0
263.0
263.0
263.0
263.0
263.0
272.0
272.0
272.0
272.0
272.0
272.0
274.0
274.0
274.0
274.0
274.0
274.0
604/604
604/604
604/604
604/604
604/604
604/604
609/609
609/609
609/609
609/609
609/609
609/609
287.0
287.0
287.0
287.0
287.0
287.0
289.0
289.0
289.0
289.0
289.0
289.0

Example: Supply voltage is 460-3-60.


AB = 452 v
BC = 464 v
AC = 455 v
Average Voltage =
=

452 + 464 + 455


3
1371
3

= 457
Determine maximum deviation from average voltage.
(AB) 457 452 = 5 v
(BC) 464 457 = 7 v
(AC) 457 455 = 2 v
Maximum deviation is 7 v.
Determine percent of voltage imbalance.
7
% Voltage Imbalance = 100 x
457
= 1.53%
This amount of phase imbalance is satisfactory as it is below the maximum allowable 2%.
IMPORTANT: If the supply voltage phase imbalance is more than 2%, contact your local
electric utility company immediately.

238

ELECTRICAL DATA 50HJ015,017


VOLTAGE
RANGE
Min
Max

COMPRESSOR
No. 1
No. 2
RLA LRA RLA LRA

208/230

187

253

20.7

156

20.7

460

414

506

10

75

575

518

633

8.2

208/230

187

253

460

414

208/230

NOMINAL
VOLTAGE
(3 Ph, 60 Hz)

UNIT
50HJ

OFM

IFM

Qty

Hp

FLA (ea)

Hp

FLA

156

0.5

1.7

2.9

8.8/
8.4

10

75

0.5

0.8

2.9

4.2

54

8.2

54

0.5

0.75

3.0

3.9

20.7

156

20.7

156

0.5

1.7

3.7

10.5/
11.0

506

10

75

10

75

0.5

0.8

3.7

4.8

187

253

32.1

195

20.7

156

0.5

1.7

5.0

15.8/
15.8

460

414

508

16.4

95

10

70

0.5

0.8

5.0

7.9

575

518

633

12

80

8.2

54

0.5

0.75

5.0

6.0

015
(Standard
IFM)

015
(Optional
IFM)

017

LEGEND

FLA
HACR
IFM
LRA
MCA
MOCP
NEC
OFM
RLA

Full Load Amps


Heating, Air Conditioning and Refrigeration
Indoor (Evaporator) Fan Motor
Locked Rotor Amps
Minimum Circuit Amps
Maximum Overcurrent Protection
National Electrical Code
Outdoor (Condenser) Fan Motor
Rated Load Amps

NOTES:
1. In compliance with NEC requirements for multimotor and combination load equipment (refer to NEC Articles 430 and 440), the overcurrent protective device for the
unit shall be fuse or HACR breaker. The Canadian units may be fuse or circuit
breaker.
2. Unbalanced 3-Phase Supply Voltage
Never operate a motor where a phase imbalance in supply voltage is greater than
2%. Use the following formula to determine the percent of voltage imbalance.
% Voltage Imbalance
= 100 x

max voltage deviation from average voltage


average voltage

ELECTRIC
HEAT*
kW
FLA

14/19
39/ 45
14/19
39/ 45
26/34
71/ 82
26/34
71/ 82
42/56**
117/135
42/56**
117/135

15
18
15
18
32
39
32
39
55**
66
55**
66

37**
37
37**
37

14/19
39/ 45
14/19
39/ 45
26/34
71/ 82
26/34
71/ 82
42/56**
117/135
42/56**
117/135

15
18
15
18
32
39
32
39
55**
66
55**
66

26/34
71/ 82
26/34
71/ 82
42/56
117/135
42/56
117/135
56/75**
156/180
56/75**
156/180

32
39
32
39
55
66
55
66
80**
96
80**
96

POWER
SUPPLY
MCA
MOCP
60/ 60
80/ 80
65/ 65
80/ 80
60/ 67
80/ 80
66/ 73
80/ 80
100/113
100/125
106/119
110/125
157/146
175/175
163/151
175/175
29
35
31
40
29
35
31
40
54
60
57
60
71
80
74
80
25
30
27
30
51
60
54
60
62/ 63
80/ 80
67/ 67
80/ 80
62/ 70
80/ 80
68/ 76
80/ 80
102/116
110/125
108/122
110/125
159/149
175/175
165/155
175/175
30
35
32
40
30
35
32
40
55
60
58
60
72
80
75
80
82/ 82
110/110
86/ 86
110/110
109/122
110/125
114/128
125/150
166/155
175/175
172/161
175/175
176/200
200/225
182/206
200/225
41
50
43
50
59
60
62
70
76
90
79
90
106
125
109
125
31
40
34
40

EXAMPLE: Supply voltage is 460-3-60.


AB = 452 v
BC = 464 v
AC = 455 v
Average Voltage =

452 + 464 + 455


3

1371
3
= 457
=

Determine maximum deviation from average voltage.


(AB) 457 452 = 5 v
(BC) 464 457 = 7 v
(AC) 457 455 = 2 v
Maximum deviation is 7 v.
Determine percent voltage imbalance.
% Voltage Imbalance = 100 x

50HJ

*Heater capacity (kW) is based on heater voltage of 208 v, 240 v, 480 v, and 600 v.
Heaters are rated at 240 v, 480 v, or 600 v. If power distribution voltage to unit varies
from rated heater voltage, heater kW will vary accordingly. To determine heater capacity at actual unit voltage, multiply 240 v, 480 v, or 600 v capacity by multipliers found in
table on page 215.
Fuse or HACR circuit breaker.
**Electric heaters are field installed.

POWER
EXHAUST
FLA
LRA

4.6
18.8

4.6
18.8

4.6
18.8

4.6
18.8

2.3
6.0

2.3
6.0

2.3
6.0

2.3
6.0

2.1
4.8

2.1
4.8

4.6
18.8

4.6
18.8

4.6
18.8

4.6
18.8

2.3
6.0

2.3
6.0

2.3
6.0

2.3
6.0

4.6
18.8

4.6
18.8

4.6
18.8

4.6
18.8

2.3
6.0

2.3
6.0

2.3
6.0

2.3
6.0

2.1
4.8

7
457

= 1.53%
This amount of phase imbalance is satisfactory as it is below the maximum allowable 2%.
IMPORTANT: If the supply voltage phase imbalance is more than 2%, contact your local electric utility company immediately.

3. MCA calculation for 50HJ015,017 units with electric heaters over 50 kW = (1.25 x
IFM amps) + (1.00 x heater FLA).

239

Electrical data 50HJ (cont)


ELECTRICAL DATA 50HJ020-028
UNIT
SIZE
50HJ

NOMINAL
VOLTAGE
(3 Ph, 60 Hz)

VOLTAGE
RANGE
Min

Max

No. 1
RLA

COMPRESSOR
No. 2

LRA

RLA LRA

RLA

ELECTRIC
HEAT

OFM

No. 3
LRA Qty

Hp

FLA
(ea)

kW

FLA

19/25

208/230

187

253

16.7

130

16.7

130

22.4

184

0.25

52/ 60

IFM
Hp

FLA

3.7

10.6/9.6

16.7/15.2

7.5

24.2/22

3.7

10.6/9.6

16.7/15.2

7.5

24.2/22

3.7

10.6/9.6

16.7/15.2

7.5

24.2/22

3.7

10.6/9.6

16.7/15.2

7.5

24.2/22

3.7

4.8

7.6

7.5

11

3.7

4.8

7.6

7.5

11

3.7

4.8

7.6

7.5

11

3.7

4.8

7.6

7.5

11

1.5

38/50

104/120

56/75 156/180

020

25

460

414

506

70

70

10.7

90

0.25

75

LEGEND
MCA
MOCP
NEC
OFM
RLA

Minimum Circuit Amps


Maximum Overcurrent Protection
National Electrical Code
Outdoor (Condenser) Fan Motor
Rated Load Amps

50HJ

*Fuse or HACR circuit breaker.


208/230 v 75-kW Electric Heat units must use dual-point wiring. The main table lists the
branch circuit values for the refrigeration part of the system. The following two tables list the
branch circuit values for the electric heat and values for a feeder circuit for both branch circuits.
NOTES:
1. In compliance with NEC requirements for multimotor and combination load equipment (refer
to NEC Articles 430 and 440), the overcurrent protective device for the unit shall be fuse or
HACR breaker. Canadian units may be fuse or circuit breaker.
2. Unbalanced 3-Phase Supply Voltage
Never operate a motor where a phase imbalance in supply voltage is greater than 2%. Use
the following formula to determine the percent of voltage imbalance.
% Voltage Imbalance
= 100 x

max voltage deviation from average voltage


average voltage

Example: Supply voltage is 460-3-60.


AB = 452 v
BC = 464 v
AC = 455 v
Average Voltage =

452 + 464 + 455


3

1371
3
= 457
=

240

30

0.7

50

FLA Full Load Amps


HACR Heating, Air Conditioning and
Refrigeration
IFM
Indoor (Evaporator) Fan Motor
LRA Locked Rotor Amps

60

90

POWER
EXHAUST
Qty Hp FLA
(ea)

2
1
5.9

2
1
5.9

2
1
5.9

2
1
5.9

2
1
5.9

2
1
5.9

2
1
5.9

2
1
5.9

2
1
5.9

2
1
5.9

2
1
5.9

2
1
5.9

2
1
3.1

2
1
3.1

2
1
3.1

2
1
3.1

2
1
3.1

2
1
3.1

2
1
3.1

2
1
3.1

2
1
3.1

2
1
3.1

2
1
3.1

2
1
3.1

POWER
SUPPLY

DISCONNECT
SIZE

MCA

MOCP*

FLA

78/ 77
90/ 89
84/ 83
96/ 94
92/ 89
104/101
78/ 87
93/102
86/ 94
101/109
95/103
110/117
143/132
158/147
151/139
166/154
160/148
175/162
78/ 77
90/ 89
84/ 83
96/ 94
92/ 89
104/101
39
45
42
48
45
51
44
51
47
55
51
59
66
74
70
77
74
82
96
104
100
107
104
112

100/ 90
100/100
100/100
100/100
100/100
125/110
100/ 90
100/110
100/100
110/110
100/110
125/125
150/150
175/150
175/150
175/175
175/150
200/175
100/ 90
100/100
100/100
100/100
100/100
125/110
45
50
50
50
50
60
45
60
50
60
60
60
80
80
80
80
80
90
100
110
110
125
125
125

83/ 82
97/ 96
90/ 89
104/102
99/ 96
112/110
83/ 82
97/ 96
90/ 89
104/102
99/ 96
112/110
132/149
145/163
139/155
152/169
147/163
161/177
83/ 82
97/ 96
90/ 89
104/102
99/ 96
112/110
42
49
45
52
49
56
42
49
45
52
49
56
75
82
78
85
82
89
109
116
112
119
116
123

Determine maximum deviation from average voltage.


(AB) 457 452 = 5 v
(BC) 464 457 = 7 v
(AC) 457 455 = 2 v
Maximum deviation is 7 v.
Determine percent of voltage imbalance.
7
% Voltage Imbalance = 100 x 457
= 1.53%
This amount of phase imbalance is satisfactory as it is below the maximum allowable 2%.
IMPORTANT: If the supply voltage phase imbalance is more than 2%, contact your
local electric utility company immediately.
3. The 75-kW 208/240-v electric heat can be factory installed but it must be wired separately in
the field.
4. The convenience outlet full load amps (FLA) are 5, 3 and 3 for 208/230, 460, 575-v units,
respectively.
5. The FLA load amps provided in the table for electric heaters are based on 208/240, 480 and
600 v.
6. MCA calculation for 50HJ units with electric heaters over 50 kW is = 1.25 x (IFM + Power
Exhaust + Convenience Outlet FLA amps) + 1.00 x (Electric Heater FLA).

ELECTRICAL DATA 50HJ020-028 (cont)


UNIT
SIZE
50HJ

NOMINAL
VOLTAGE
(3 Ph, 60 Hz)

VOLTAGE
RANGE
Min

COMPRESSOR
No. 2

No. 1

Max

RLA

LRA

RLA

LRA

RLA

ELECTRIC
HEAT

OFM

No. 3
LRA

Qty

Hp

FLA
(ea)

kW

FLA

575

518

633

55

55

9.3

73

0.25

Hp

FLA

3.9

6.1

7.5

3.9

6.1

7.5

3.9

6.1

7.5

3.9

6.1

7.5

24.8

020

IFM

24

0.7

48.3

46

78

75

POWER
EXHAUST
Qty Hp FLA
(ea)

2
1
2.4

2
1
2.4

2
1
2.4

2
1
2.4

2
1
2.4

2
1
2.4

2
1
2.4

2
1
2.4

2
1
2.4

2
1
2.4

2
1
2.4

2
1
2.4

POWER
SUPPLY

DISCONNECT
SIZE

MCA

MOCP*

FLA

32
37
35
39
37
42
35
41
38
44
41
47
62
68
65
71
69
75
80
86
83
89
86
92

40
45
40
45
45
50
40
45
40
45
45
50
70
70
70
80
70
80
90
90
90
100
100
100

35
40
37
43
40
46
35
40
37
43
40
46
57
63
60
65
63
69
91
96
93
99
97
102

ELECTRIC HEAT BRANCH CIRCUIT 208/240 75-kW ELECTRIC HEAT


VOLTAGE
RANGE

COMPRESSOR
No. 2

NOMINAL
VOLTAGE
(3 Ph, 60 Hz)

Min

Max

RLA

LRA

RLA

LRA

RLA

LRA

Qty

Hp

020

208/240

187

253

No. 1

ELECTRIC
HEAT

OFM

UNIT
SIZE
50HJ

No. 3

FLA
(ea)

IFM

kW

FLA

Hp

FLA

56/75

156/180

POWER
EXHAUST
Qty Hp FLA
(ea)

POWER
SUPPLY

DISCONNECT
SIZE

MCA

MOCP*

FLA

156/180

175/200

179/207

FEEDER CIRCUIT FOR 208/230 UNIT WITH 75-kW ELECTRIC HEAT


UNIT
SIZE
50HJ

NOMINAL
VOLTAGE
(3 Ph, 60 Hz)

020

208/230

VOLTAGE
RANGE
Min

187

Max

253

No. 1
RLA

LRA

16.7

FLA Full Load Amps


HACR Heating, Air Conditioning and
Refrigeration
IFM
Indoor (Evaporator) Fan Motor
LRA Locked Rotor Amps

COMPRESSOR
No. 2

130

RLA

16.7

LEGEND
MCA
MOCP
NEC
OFM
RLA

LRA

130

RLA

22.4

LRA

184

Qty

Hp

0.25

Minimum Circuit Amps


Maximum Overcurrent Protection
National Electrical Code
Outdoor (Condenser) Fan Motor
Rated Load Amps

*Fuse or HACR circuit breaker.


208/230 v 75-kW Electric Heat units must use dual-point wiring. The main table lists the
branch circuit values for the refrigeration part of the system. The following two tables list the
branch circuit values for the electric heat and values for a feeder circuit for both branch circuits.
NOTES:
1. In compliance with NEC requirements for multimotor and combination load equipment (refer
to NEC Articles 430 and 440), the overcurrent protective device for the unit shall be fuse or
HACR breaker. Canadian units may be fuse or circuit breaker.
2. Unbalanced 3-Phase Supply Voltage
Never operate a motor where a phase imbalance in supply voltage is greater than 2%. Use
the following formula to determine the percent of voltage imbalance.
% Voltage Imbalance
max voltage deviation from average voltage
average voltage

Example: Supply voltage is 460-3-60.


AB = 452 v
BC = 464 v
AC = 455 v
Average Voltage =

FLA
(ea)

1.5

kW

56/75

FLA

156/180

IFM
Hp

FLA

3.7

10.6/ 9.6

16.7/15.2

7.5

24.2/22.0

POWER
EXHAUST
Qty Hp FLA
(ea)

2
1
5.9

2
1
5.9

2
1
5.9

POWER
SUPPLY

DISCONNECT
SIZE

MCA

MOCP*

FLA

169/192
184/207
177/199
192/214
186/208
201/222

200/225
200/225
200/225
200/225
200/225
225/225

192/218
205/232
199/224
212/238
207/232
221/246

Determine maximum deviation from average voltage.


(AB) 457 452 = 5 v
(BC) 464 457 = 7 v
(AC) 457 455 = 2 v
Maximum deviation is 7 v.
Determine percent of voltage imbalance.
7
% Voltage Imbalance = 100 x 457
= 1.53%
This amount of phase imbalance is satisfactory as it is below the maximum allowable 2%.
IMPORTANT: If the supply voltage phase imbalance is more than 2%, contact your
local electric utility company immediately.
3. The 75-kW 208/240-v electric heat can be factory installed but it must be wired separately in
the field.
4. The convenience outlet full load amps (FLA) are 5, 3 and 3 for 208/230, 460, 575-v units,
respectively.
5. The FLA load amps provided in the table for electric heaters are based on 208/240, 480 and
600 v.
6. MCA calculation for 50HJ units with electric heaters over 50 kW is = 1.25 x (IFM + Power
Exhaust + Convenience Outlet FLA amps) + 1.00 x (Electric Heater FLA).

452 + 464 + 455


3

1371
3
= 457
=

241

50HJ

= 100 x

ELECTRIC
HEAT

OFM

No. 3

Electrical data 50HJ (cont)


ELECTRICAL DATA 50HJ020-028 (cont)
UNIT
SIZE
50HJ

NOMINAL
VOLTAGE
(3 Ph, 60 Hz)

VOLTAGE
RANGE
Min

Max

No. 1
RLA

LRA

COMPRESSOR
No. 2
RLA

LRA

RLA

LRA

ELECTRIC
HEAT

OFM

No. 3
Qty

Hp

FLA
(ea)

kW

19/25

208/230

187

253

22.4

184

22.4

184

22.4

184

0.25

FLA

IFM
Hp

FLA

3.7

10.6/9.6

16.7/15.2

7.5

24.2/22

10

30.8/28

3.7

10.6/9.6

16.7/15.2

7.5

24.2/22

10

30.8/28

3.7

10.6/9.6

16.7/15.2

7.5

24.2/22

10

30.8/28

3.7

10.6/9.6

16.7/15.2

7.5

24.2/22

10

30.8/28

3.7

4.8

7.6

7.5

11

10

14

3.7

4.8

7.6

7.5

11

10

14

3.7

4.8

7.6

7.5

11

10

14

3.7

4.8

7.6

7.5

11

10

14

52/60

1.5

38/50

56/75

104/120

156/180

024

25

460

414

506

10.7

90

10.7

90

10.7

90

0.25

50HJ

75

242

30

0.7

50

See legend and notes on next page.

60

90

POWER
EXHAUST
Qty Hp FLA
(ea)

2
1
5.9

2
1
5.9

2
1
5.9

2
1
5.9

2
1
5.9

2
1
5.9

2
1
5.9

2
1
5.9

2
1
5.9

2
1
5.9

2
1
5.9

2
1
5.9

2
1
5.9

2
1
5.9

2
1
5.9

2
1
5.9

2
1
3.1

2
1
3.1

2
1
3.1

2
1
3.1

2
1
3.1

2
1
3.1

2
1
3.1

2
1
3.1

2
1
3.1

2
1
3.1

2
1
3.1

2
1
3.1

2
1
3.1

2
1
3.1

2
1
3.1

2
1
3.1

POWER
SUPPLY

DISCONNECT
SIZE

MCA

MOCP*

FLA

89/ 88
101/100
96/ 94
107/106
103/101
115/113
112/108
124/120
89/ 88
101/102
96/ 94
107/109
103/103
115/117
112/110
124/125
143/132
158/147
151/139
166/154
160/148
175/162
169/155
183/170
89/ 88
101/100
96/ 94
107/106
103/101
115/113
112/108
124/120
42
49
45
51
49
55
52
59
44
51
47
55
51
59
55
63
66
74
70
77
74
82
78
85
96
104
100
107
104
112
108
115

100/100
110/110
100/100
125/125
125/110
125/125
125/125
150/125
100/100
110/110
100/100
125/125
125/110
125/125
125/125
150/125
150/150
175/150
175/150
175/175
175/150
200/175
175/175
200/175
100/100
110/110
100/100
125/125
125/110
125/125
125/125
150/125
50
50
50
60
50
60
60
60
50
60
50
60
60
60
60
70
80
80
80
80
80
90
90
90
100
110
110
125
125
125
125
125

96/ 95
110/109
103/102
117/115
112/109
126/123
120/116
133/130
96/ 95
110/109
103/102
117/115
112/109
126/123
120/116
133/130
132/149
145/163
139/155
152/169
147/163
161/177
155/170
169/184
96/ 95
110/109
103/102
117/115
112/109
126/123
120/116
133/130
46
53
49
56
53
60
56
63
46
53
49
56
53
60
56
63
75
82
78
85
82
89
85
92
109
116
112
119
116
123
120
127

ELECTRICAL DATA 50HJ020-028 (cont)


UNIT
SIZE
50HJ

NOMINAL
VOLTAGE
(3 Ph, 60 Hz)

VOLTAGE
RANGE
Min

COMPRESSOR
No. 2

No. 1

Max

RLA

LRA

RLA

LRA

RLA

ELECTRIC
HEAT

OFM

No. 3
LRA

Qty

Hp

FLA
(ea)

kW

FLA

575

518

633

9.3

73

9.3

73

9.3

73

0.25

Hp

24.8

024

IFM

24

FLA

6.1

7.5

10

11

6.1

7.5

10

11

6.1

7.5

10

11

6.1

7.5

10

11

0.7

48.3

46

78

75

POWER
EXHAUST
Qty Hp FLA
(ea)

2
1
2.4

2
1
2.4

2
1
2.4

2
1
2.4

2
1
2.4

2
1
2.4

2
1
2.4

2
1
2.4

2
1
2.4

2
1
2.4

2
1
2.4

2
1
2.4

POWER
SUPPLY

DISCONNECT
SIZE

MCA

MOCP*

FLA

39
44
42
47
44
49
39
44
42
47
44
50
65
71
69
75
71
77
83
89
86
92
89
95

45
50
50
50
50
60
45
50
50
50
50
60
70
80
70
80
80
80
90
100
100
100
100
100

42
48
46
51
48
53
42
48
46
51
48
53
60
65
63
69
66
71
93
99
97
102
99
104

ELECTRIC HEAT BRANCH CIRCUIT 208/240 75-kW ELECTRIC HEAT


VOLTAGE
RANGE

COMPRESSOR
No. 2

NOMINAL
VOLTAGE
(3 Ph, 60 Hz)

Min

Max

RLA

LRA

RLA

LRA

RLA

LRA

Qty

Hp

024

208/240

187

253

No. 1

ELECTRIC
HEAT

OFM

UNIT
SIZE
50HJ

No. 3

FLA
(ea)

IFM

kW

FLA

Hp

FLA

56/75

156/180

POWER
EXHAUST
Qty Hp FLA
(ea)

POWER
SUPPLY

DISCONNECT
SIZE

MCA

MOCP*

FLA

156/180

175/200

179/207

FEEDER CIRCUIT FOR 208/230 UNIT WITH 75-kW ELECTRIC HEAT


UNIT
SIZE
50HJ

024

NOMINAL
VOLTAGE
(3 Ph, 60 Hz)

208/230

VOLTAGE
RANGE
Min

187

Max

253

No. 1
RLA

LRA

22.4

FLA Full Load Amps


HACR Heating, Air Conditioning and
Refrigeration
IFM
Indoor (Evaporator) Fan Motor
LRA Locked Rotor Amps

COMPRESSOR
No. 2

184

RLA

22.4

LEGEND
MCA
MOCP
NEC
OFM
RLA

LRA

184

RLA

22.4

LRA

184

Qty

Hp

0.25

Minimum Circuit Amps


Maximum Overcurrent Protection
National Electrical Code
Outdoor (Condenser) Fan Motor
Rated Load Amps

*Fuse or HACR circuit breaker.


208/230 v 75-kW Electric Heat units must use dual-point wiring. The main table lists the
branch circuit values for the refrigeration part of the system. The following two tables list the
branch circuit values for the electric heat and values for a feeder circuit for both branch circuits.

Average Voltage =

FLA
(ea)

1.5

kW

56/75

FLA

IFM
Hp

FLA

3.7

10.6/9.6

16.7/15.2

7.5

24.2/22

10

30.8/28

156/180

POWER
EXHAUST
Qty Hp FLA
(ea)

2
1
5.9

2
1
5.9

2
1
5.9

2
1
5.9

POWER
SUPPLY

DISCONNECT
SIZE

MCA

MOCP*

FLA

169/192
184/207
177/199
192/214
186/208
201/222
195/215
209/230

200/225
200/225
200/225
200/225
200/225
225/225
225/225
225/250

192/218
205/232
199/224
212/238
207/232
221/246
215/239
228/253

Determine maximum deviation from average voltage.


(AB) 457 452 = 5 v
(BC) 464 457 = 7 v
(AC) 457 455 = 2 v
Maximum deviation is 7 v.
Determine percent of voltage imbalance.
7
% Voltage Imbalance = 100 x 457
= 1.53%
This amount of phase imbalance is satisfactory as it is below the maximum allowable 2%.
IMPORTANT: If the supply voltage phase imbalance is more than 2%, contact your
local electric utility company immediately.
3. The 75-kW 208/240-v electric heat can be factory installed but it must be wired separately in
the field.
4. The convenience outlet full load amps (FLA) are 5, 3 and 3 for 208/230, 460, 575-v units,
respectively.
5. The FLA load amps provided in the table for electric heaters are based on 208/240, 480 and
600 v.
6. MCA calculation for 50HJ units with electric heaters over 50 kW is = 1.25 x (IFM + Power
Exhaust + Convenience Outlet FLA amps) + 1.00 x (Electric Heater FLA).

452 + 464 + 455


3

1371
3
= 457
=

243

50HJ

NOTES:
1. In compliance with NEC requirements for multimotor and combination load equipment (refer
to NEC Articles 430 and 440), the overcurrent protective device for the unit shall be fuse or
HACR breaker. Canadian units may be fuse or circuit breaker.
2. Unbalanced 3-Phase Supply Voltage
Never operate a motor where a phase imbalance in supply voltage is greater than 2%. Use
the following formula to determine the percent of voltage imbalance.
% Voltage Imbalance
max voltage deviation from average voltage
= 100 x
average voltage
Example: Supply voltage is 460-3-60.
AB = 452 v
BC = 464 v
AC = 455 v

ELECTRIC
HEAT

OFM

No. 3

Electrical data 50HJ (cont)


ELECTRICAL DATA 50HJ020-028 (cont)
UNIT
SIZE
50HJ

NOMINAL
VOLTAGE
(3 Ph, 60 Hz)

VOLTAGE
RANGE
Min

Max

COMPRESSOR
No. 2

No. 1
RLA

LRA

RLA

LRA

RLA

LRA

ELECTRIC
HEAT

OFM

No. 3
Qty

Hp

FLA
(ea)

kW

19/25

208/230

187

253

47.1

245

47.1

245

0.25

FLA

52/60

IFM
Hp

FLA

16.7/15.2

7.5

24.2/22

10

30.8/28

16.7/15.2

7.5

24.2/22

10

30.8/28

16.7/15.2

7.5

24.2/22

10

30.8/28

16.7/15.2

7.5

24.2/22

10

30.8/28

7.6

7.5

11

10

14

7.6

7.5

11

10

14

7.6

7.5

11

10

14

7.6

7.5

11

10

14

1.5

38/50

56/75

104/120

156/180

028

25

460

414

506

19.6

125

19.6

125

0.25

75

LEGEND
MCA
MOCP
NEC
OFM
RLA

Minimum Circuit Amps


Maximum Overcurrent Protection
National Electrical Code
Outdoor (Condenser) Fan Motor
Rated Load Amps

50HJ

*Fuse or HACR circuit breaker.


208/230 v 75-kW Electric Heat units must use dual-point wiring. The main table lists the
branch circuit values for the refrigeration part of the system. The following two tables list the
branch circuit values for the electric heat and values for a feeder circuit for both branch circuits.
NOTES:
1. In compliance with NEC requirements for multimotor and combination load equipment (refer
to NEC Articles 430 and 440), the overcurrent protective device for the unit shall be fuse or
HACR breaker. Canadian units may be fuse or circuit breaker.
2. Unbalanced 3-Phase Supply Voltage
Never operate a motor where a phase imbalance in supply voltage is greater than 2%. Use
the following formula to determine the percent of voltage imbalance.
% Voltage Imbalance
= 100 x

max voltage deviation from average voltage


average voltage

Example: Supply voltage is 460-3-60.


AB = 452 v
BC = 464 v
AC = 455 v
Average Voltage =

452 + 464 + 455


3

1371
3
= 457
=

244

30

0.7

50

FLA Full Load Amps


HACR Heating, Air Conditioning and
Refrigeration
IFM
Indoor (Evaporator) Fan Motor
LRA Locked Rotor Amps

60

90

POWER
EXHAUST
Qty Hp FLA
(ea)

2
1
5.9

2
1
5.9

2
1
5.9

2
1
5.9

2
1
5.9

2
1
5.9

2
1
5.9

2
1
5.9

2
1
5.9

2
1
5.9

2
1
5.9

2
1
5.9

2
1
3.1

2
1
3.1

2
1
3.1

2
1
3.1

2
1
3.1

2
1
3.1

2
1
3.1

2
1
3.1

2
1
3.1

2
1
3.1

2
1
3.1

2
1
3.1

POWER
SUPPLY

DISCONNECT
SIZE

MCA

MOCP*

FLA

132/130
143/142
139/137
151/149
146/143
158/155
132/130
143/142
139/137
151/149
146/143
158/155
151/139
166/154
160/148
175/162
169/155
183/170
132/130
143/142
139/137
151/149
146/143
158/155
56
62
59
66
62
69
56
62
59
66
62
69
70
77
74
82
78
85
100
107
104
112
108
115

175/175
175/175
175/175
175/175
175/175
200/200
175/175
175/175
175/175
175/175
175/175
200/200
175/175
175/175
175/175
200/175
175/175
200/200
175/175
175/175
175/175
175/175
175/175
200/200
60
80
60
80
80
80
60
80
60
80
80
80
80
80
80
90
90
90
110
125
125
125
125
125

138/136
151/150
147/144
160/158
154/151
168/164
138/136
151/150
147/144
160/158
154/151
168/164
139/155
152/169
147/163
161/177
155/170
169/184
138/136
151/150
147/144
160/158
154/151
168/164
59
66
63
70
66
73
59
66
63
70
66
73
78
85
82
89
85
92
112
119
116
123
120
127

Determine maximum deviation from average voltage.


(AB) 457 452 = 5 v
(BC) 464 457 = 7 v
(AC) 457 455 = 2 v
Maximum deviation is 7 v.
Determine percent of voltage imbalance.
7
% Voltage Imbalance = 100 x 457
= 1.53%
This amount of phase imbalance is satisfactory as it is below the maximum allowable 2%.
IMPORTANT: If the supply voltage phase imbalance is more than 2%, contact your
local electric utility company immediately.
3. The 75-kW 208/240-v electric heat can be factory installed but it must be wired separately in
the field.
4. The convenience outlet full load amps (FLA) are 5, 3 and 3 for 208/230, 460, 575-v units,
respectively.
5. The FLA load amps provided in the table for electric heaters are based on 208/240, 480 and
600 v.
6. MCA calculation for 50HJ units with electric heaters over 50 kW is = 1.25 x (IFM + Power
Exhaust + Convenience Outlet FLA amps) + 1.00 x (Electric Heater FLA).

ELECTRICAL DATA 50HJ020-028 (cont)


UNIT
SIZE
50HJ

NOMINAL
VOLTAGE
(3 Ph, 60 Hz)

VOLTAGE
RANGE
Min

COMPRESSOR
No. 2

No. 1

Max

RLA

LRA

RLA

LRA

RLA

ELECTRIC
HEAT

OFM

No. 3
LRA

Qty

Hp

FLA
(ea)

kW

FLA

575

518

633

15.8

100

15.8

100

0.25

Hp

24.8

028

IFM

24

FLA

6.1

7.5

10

11

6.1

7.5

10

11

6.1

7.5

10

11

6.1

7.5

10

11

0.7

48.3

46

78

75

POWER
EXHAUST
Qty Hp FLA
(ea)

2
1
2.4

2
1
2.4

2
1
2.4

2
1
2.4

2
1
2.4

2
1
2.4

2
1
2.4

2
1
2.4

2
1
2.4

2
1
2.4

2
1
2.4

2
1
2.4

POWER
SUPPLY

DISCONNECT
SIZE

MCA

MOCP*

FLA

46
51
49
54
51
56
46
51
49
54
51
56
65
71
69
75
71
77
83
89
86
92
89
95

60
60
60
60
60
60
60
60
60
60
60
60
70
80
70
80
80
80
90
100
100
100
100
100

48
54
52
57
54
59
48
54
52
57
54
59
60
65
63
69
66
71
93
99
97
102
99
104

ELECTRIC HEAT BRANCH CIRCUIT 208/240 75-kW ELECTRIC HEAT


VOLTAGE
RANGE

COMPRESSOR
No. 2

NOMINAL
VOLTAGE
(3 Ph, 60 Hz)

Min

Max

RLA

LRA

RLA

LRA

RLA

LRA

Qty

Hp

028

208/240

187

253

No. 1

ELECTRIC
HEAT

OFM

UNIT
SIZE
50HJ

No. 3

FLA
(ea)

IFM

kW

FLA

Hp

FLA

56/75

156/180

POWER
EXHAUST
Qty Hp FLA
(ea)

POWER
SUPPLY

DISCONNECT
SIZE

MCA

MOCP*

FLA

156/180

175/200

179/207

FEEDER CIRCUIT FOR 208/230 UNIT WITH 75-kW ELECTRIC HEAT


UNIT
SIZE
50HJ

NOMINAL
VOLTAGE
(3 Ph, 60 Hz)

028

208/230

VOLTAGE
RANGE
Min

187

Max

253

No. 1
RLA

LRA

47.1

FLA Full Load Amps


HACR Heating, Air Conditioning and
Refrigeration
IFM
Indoor (Evaporator) Fan Motor
LRA Locked Rotor Amps

COMPRESSOR
No. 2

245

RLA

47.1

LEGEND
MCA
MOCP
NEC
OFM
RLA

LRA

245

RLA

LRA

Qty

Hp

0.25

Minimum Circuit Amps


Maximum Overcurrent Protection
National Electrical Code
Outdoor (Condenser) Fan Motor
Rated Load Amps

*Fuse or HACR circuit breaker.


208/230 v 75-kW Electric Heat units must use dual-point wiring. The main table lists the
branch circuit values for the refrigeration part of the system. The following two tables list the
branch circuit values for the electric heat and values for a feeder circuit for both branch circuits.
NOTES:
1. In compliance with NEC requirements for multimotor and combination load equipment (refer
to NEC Articles 430 and 440), the overcurrent protective device for the unit shall be fuse or
HACR breaker. Canadian units may be fuse or circuit breaker.
2. Unbalanced 3-Phase Supply Voltage
Never operate a motor where a phase imbalance in supply voltage is greater than 2%. Use
the following formula to determine the percent of voltage imbalance.
% Voltage Imbalance
max voltage deviation from average voltage
average voltage

Example: Supply voltage is 460-3-60.


AB = 452 v
BC = 464 v
AC = 455 v
Average Voltage =

FLA
(ea)

1.5

kW

56/75

FLA

156/180

IFM
Hp

FLA

16.7/15.2

7.5

24.2/22

10

30.8/28

POWER
EXHAUST
Qty Hp FLA
(ea)

2
1
5.9

2
1
5.9

2
1
5.9

POWER
SUPPLY

DISCONNECT
SIZE

MCA

MOCP*

FLA

177/199
192/214
186/208
201/222
195/215
209/230

200/225
200/225
200/225
225/225
225/225
225/250

199/224
212/238
207/232
221/246
215/239
228/253

Determine maximum deviation from average voltage.


(AB) 457 452 = 5 v
(BC) 464 457 = 7 v
(AC) 457 455 = 2 v
Maximum deviation is 7 v.
Determine percent of voltage imbalance.
7
% Voltage Imbalance = 100 x 457
= 1.53%
This amount of phase imbalance is satisfactory as it is below the maximum allowable 2%.
IMPORTANT: If the supply voltage phase imbalance is more than 2%, contact your
local electric utility company immediately.
3. The 75-kW 208/240-v electric heat can be factory installed but it must be wired separately in
the field.
4. The convenience outlet full load amps (FLA) are 5, 3 and 3 for 208/230, 460, 575-v units,
respectively.
5. The FLA load amps provided in the table for electric heaters are based on 208/240, 480 and
600 v.
6. MCA calculation for 50HJ units with electric heaters over 50 kW is = 1.25 x (IFM + Power
Exhaust + Convenience Outlet FLA amps) + 1.00 x (Electric Heater FLA).

452 + 464 + 455


3

1371
3
= 457
=

245

50HJ

= 100 x

ELECTRIC
HEAT

OFM

No. 3

Electrical data 50HJ (cont)


ELECTRICAL DATA 50HJ020-028 WITH OPTIONAL CONVENIENCE OUTLET
UNIT
SIZE
50HJ

NOMINAL
VOLTAGE
(3 Ph, 60 Hz)

VOLTAGE
RANGE
Min

Max

COMPRESSOR
No. 2

No. 1
RLA

LRA

RLA

LRA

RLA

LRA

ELECTRIC
HEAT

OFM

No. 3
Qty

Hp

FLA
(ea)

kW

19/25

208/230

187

253

16.7

130

16.7

130

22.4

184

0.25

FLA

52/60

IFM
Hp

FLA

3.7

10.6/9.6

16.7/15.2

7.5

24.2/22

3.7

10.6/9.6

16.7/15.2

7.5

24.2/22

3.7

10.6/9.6

16.7/15.2

7.5

24.2/22

3.7

10.6/9.6

16.7/15.2

7.5

24.2/22

3.7

4.8

7.6

7.5

11

3.7

4.8

7.6

7.5

11

3.7

4.8

7.6

7.5

11

3.7

4.8

7.6

7.5

11

1.5

38/50

56/75

104/120

156/180

020

25

460

414

506

70

70

10.7

90

0.25

75

LEGEND
MCA
MOCP
NEC
OFM
RLA

Minimum Circuit Amps


Maximum Overcurrent Protection
National Electrical Code
Outdoor (Condenser) Fan Motor
Rated Load Amps

50HJ

*Fuse or HACR circuit breaker.


208/230 v 75-kW Electric Heat units must use dual-point wiring. The main table lists the
branch circuit values for the refrigeration part of the system. The following two tables list the
branch circuit values for the electric heat and values for a feeder circuit for both branch circuits.
NOTES:
1. In compliance with NEC requirements for multimotor and combination load equipment (refer
to NEC Articles 430 and 440), the overcurrent protective device for the unit shall be fuse or
HACR breaker. Canadian units may be fuse or circuit breaker.
2. Unbalanced 3-Phase Supply Voltage
Never operate a motor where a phase imbalance in supply voltage is greater than 2%. Use
the following formula to determine the percent of voltage imbalance.
% Voltage Imbalance
= 100 x

max voltage deviation from average voltage


average voltage

Example: Supply voltage is 460-3-60.


AB = 452 v
BC = 464 v
AC = 455 v
Average Voltage =

452 + 464 + 455


3

1371
3
= 457
=

246

30

0.7

50

FLA Full Load Amps


HACR Heating, Air Conditioning and
Refrigeration
IFM
Indoor (Evaporator) Fan Motor
LRA Locked Rotor Amps

60

90

POWER
EXHAUST
Qty Hp FLA
(ea)

2
1
5.9

2
1
5.9

2
1
5.9

2
1
5.9

2
1
5.9

2
1
5.9

2
1
5.9

2
1
5.9

2
1
5.9

2
1
5.9

2
1
5.9

2
1
5.9

2
1
3.1

2
1
3.1

2
1
3.1

2
1
3.1

2
1
3.1

2
1
3.1

2
1
3.1

2
1
3.1

2
1
3.1

2
1
3.1

2
1
3.1

2
1
3.1

POWER
SUPPLY

DISCONNECT
SIZE

MCA

MOCP*

FLA

83/ 82
95/ 94
89/ 88
101/ 99
97/ 94
109/106
85/ 93
99/108
92/100
107/115
102/109
116/124
150/138
164/153
157/145
172/160
167/154
181/169
83/ 82
95/ 94
89/ 88
101/ 99
97/ 94
109/106
42
48
45
51
48
54
47
55
51
59
55
63
70
78
73
81
78
85
100
108
103
111
108
115

100/100
100/100
100/100
110/100
100/100
125/125
100/100
100/110
100/110
110/125
110/110
125/125
150/150
175/175
175/150
175/175
175/175
200/175
100/100
100/100
100/100
110/100
100/100
125/125
50
50
50
60
50
60
50
60
60
60
60
70
80
80
80
90
80
90
110
125
125
125
125
125

89/ 88
103/101
96/ 94
110/108
105/102
118/116
89/ 88
103/101
96/ 94
110/108
105/102
118/116
138/155
151/168
145/161
158/175
153/169
167/183
89/ 88
103/101
96/ 94
110/108
105/102
118/116
45
52
48
56
52
59
45
52
48
56
52
59
78
85
81
88
85
92
112
120
116
123
120
127

Determine maximum deviation from average voltage.


(AB) 457 452 = 5 v
(BC) 464 457 = 7 v
(AC) 457 455 = 2 v
Maximum deviation is 7 v.
Determine percent of voltage imbalance.
7
% Voltage Imbalance = 100 x 457
= 1.53%
This amount of phase imbalance is satisfactory as it is below the maximum allowable 2%.
IMPORTANT: If the supply voltage phase imbalance is more than 2%, contact your
local electric utility company immediately.
3. The 75-kW 208/240-v electric heat can be factory installed but it must be wired separately in
the field.
4. The convenience outlet full load amps (FLA) are 5, 3 and 3 for 208/230, 460, 575-v units,
respectively.
5. The FLA load amps provided in the table for electric heaters are based on 208/240, 480 and
600 v.
6. MCA calculation for 50HJ units with electric heaters over 50 kW is = 1.25 x (IFM + Power
Exhaust + Convenience Outlet FLA amps) + 1.00 x (Electric Heater FLA).

ELECTRICAL DATA 50HJ020-028 WITH OPTIONAL CONVENIENCE OUTLET


UNIT
SIZE
50HJ

NOMINAL
VOLTAGE
(3 Ph, 60 Hz)

VOLTAGE
RANGE
Min

COMPRESSOR
No. 2

No. 1

Max

RLA

LRA

RLA

LRA

RLA

ELECTRIC
HEAT

OFM

No. 3
LRA

Qty

Hp

FLA
(ea)

kW

FLA

575

518

633

55

55

9.3

73

0.25

Hp

FLA

3.9

6.1

7.5

3.9

6.1

7.5

3.9

6.1

7.5

3.9

6.1

7.5

24.8

020

IFM

24

0.7

48.3

78

46

75

POWER
EXHAUST
Qty Hp FLA
(ea)

2
1
2.4

2
1
2.4

2
1
2.4

2
1
2.4

2
1
2.4

2
1
2.4

2
1
2.4

2
1
2.4

2
1
2.4

2
1
2.4

2
1
2.4

2
1
2.4

POWER
SUPPLY

DISCONNECT
SIZE

MCA

MOCP*

FLA

35
40
38
42
40
45
39
45
41
47
45
51
66
72
69
75
73
79
84
90
86
92
90
96

40
45
45
50
45
50
40
45
45
50
50
60
70
80
70
80
80
80
90
100
100
100
100
100

38
43
40
46
44
49
38
43
40
46
44
49
61
66
63
69
67
72
94
100
97
102
100
106

ELECTRIC HEAT BRANCH CIRCUIT 208/240 75-kW ELECTRIC HEAT


VOLTAGE
RANGE

COMPRESSOR
No. 2

NOMINAL
VOLTAGE
(3 Ph, 60 Hz)

Min

Max

RLA

LRA

RLA

LRA

RLA

LRA

Qty

Hp

020

208/240

187

253

No. 1

ELECTRIC
HEAT

OFM

UNIT
SIZE
50HJ

No. 3

FLA
(ea)

IFM

kW

FLA

Hp

FLA

56/75

156/180

POWER
EXHAUST
Qty Hp FLA
(ea)

POWER
SUPPLY

DISCONNECT
SIZE

MCA

MOCP*

FLA

156/180

175/200

179/207

FEEDER CIRCUIT FOR 208/230 UNIT WITH 75-kW ELECTRIC HEAT


UNIT
SIZE
50HJ

NOMINAL
VOLTAGE
(3 Ph, 60 Hz)

020

208/230

VOLTAGE
RANGE
Min

187

Max

253

No. 1
RLA

LRA

16.7

FLA Full Load Amps


HACR Heating, Air Conditioning and
Refrigeration
IFM
Indoor (Evaporator) Fan Motor
LRA Locked Rotor Amps

COMPRESSOR
No. 2

130

RLA

16.7

LEGEND
MCA
MOCP
NEC
OFM
RLA

LRA

130

RLA

22.4

LRA

184

Qty

Hp

0.25

Minimum Circuit Amps


Maximum Overcurrent Protection
National Electrical Code
Outdoor (Condenser) Fan Motor
Rated Load Amps

*Fuse or HACR circuit breaker.


208/230 v 75-kW Electric Heat units must use dual-point wiring. The main table lists the
branch circuit values for the refrigeration part of the system. The following two tables list the
branch circuit values for the electric heat and values for a feeder circuit for both branch circuits.
NOTES:
1. In compliance with NEC requirements for multimotor and combination load equipment (refer
to NEC Articles 430 and 440), the overcurrent protective device for the unit shall be fuse or
HACR breaker. Canadian units may be fuse or circuit breaker.
2. Unbalanced 3-Phase Supply Voltage
Never operate a motor where a phase imbalance in supply voltage is greater than 2%. Use
the following formula to determine the percent of voltage imbalance.
% Voltage Imbalance
max voltage deviation from average voltage
average voltage

Example: Supply voltage is 460-3-60.


AB = 452 v
BC = 464 v
AC = 455 v
Average Voltage =

FLA
(ea)

1.5

kW

56/75

FLA

156/180

IFM
Hp

FLA

3.7

10.6/9.6

16.7/15.2

7.5

24.2/22

POWER
EXHAUST
Qty Hp FLA
(ea)

2
1
5.9

2
1
5.9

2
1
5.9

POWER
SUPPLY

DISCONNECT
SIZE

MCA

MOCP*

FLA

176/198
190/213
183/205
198/220
193/214
207/229

200/225
200/225
200/225
200/225
200/225
225/250

197/224
211/237
204/230
218/244
213/238
227/252

Determine maximum deviation from average voltage.


(AB) 457 452 = 5 v
(BC) 464 457 = 7 v
(AC) 457 455 = 2 v
Maximum deviation is 7 v.
Determine percent of voltage imbalance.
7
% Voltage Imbalance = 100 x 457
= 1.53%
This amount of phase imbalance is satisfactory as it is below the maximum allowable 2%.
IMPORTANT: If the supply voltage phase imbalance is more than 2%, contact your
local electric utility company immediately.
3. The 75-kW 208/240-v electric heat can be factory installed but it must be wired separately in
the field.
4. The convenience outlet full load amps (FLA) are 5, 3 and 3 for 208/230, 460, 575-v units,
respectively.
5. The FLA load amps provided in the table for electric heaters are based on 208/240, 480 and
600 v.
6. MCA calculation for 50HJ units with electric heaters over 50 kW is = 1.25 x (IFM + Power
Exhaust + Convenience Outlet FLA amps) + 1.00 x (Electric Heater FLA).

452 + 464 + 455


3

1371
3
= 457
=

247

50HJ

= 100 x

ELECTRIC
HEAT

OFM

No. 3

Electrical data 50HJ (cont)


ELECTRICAL DATA 50HJ020-028 WITH OPTIONAL CONVENIENCE OUTLET (cont)
UNIT
SIZE
50HJ

NOMINAL
VOLTAGE
(3 Ph, 60 Hz)

VOLTAGE
RANGE
Min

Max

No. 1
RLA

LRA

COMPRESSOR
No. 2
RLA

LRA

RLA

LRA

ELECTRIC
HEAT

OFM

No. 3
Qty

Hp

FLA
(ea)

kW

19/25

208/230

187

253

22.4

184

22.4

184

22.4

184

0.25

FLA

IFM
Hp

FLA

3.7

10.6/9.6

16.7/15.2

7.5

24.2/22

10

30.8/28

3.7

10.6/9.6

16.7/15.2

7.5

24.2/22

10

30.8/28

3.7

10.6/9.6

16.7/15.2

7.5

24.2/22

10

30.8/28

3.7

10.6/9.6

16.7/15.2

7.5

24.2/22

10

30.8/28

3.7

4.8

7.6

7.5

11

10

14

3.7

4.8

7.6

7.5

11

10

14

3.7

4.8

7.6

7.5

11

10

14

3.7

4.8

7.6

7.5

11

10

14

52/60

1.5

38/50

56/75

104/120

156/180

024

25

460

414

506

10.7

90

10.7

90

10.7

90

0.25

50HJ

75

248

30

0.7

50

See legend and notes on next page.

60

90

POWER
EXHAUST
Qty Hp FLA
(ea)

2
1
5.9

2
1
5.9

2
1
5.9

2
1
5.9

2
1
5.9

2
1
5.9

2
1
5.9

2
1
5.9

2
1
5.9

2
1
5.9

2
1
5.9

2
1
5.9

2
1
5.9

2
1
5.9

2
1
5.9

2
1
5.9

2
1
3.1

2
1
3.1

2
1
3.1

2
1
3.1

2
1
3.1

2
1
3.1

2
1
3.1

2
1
3.1

2
1
3.1

2
1
3.1

2
1
3.1

2
1
3.1

2
1
3.1

2
1
3.1

2
1
3.1

2
1
3.1

POWER
SUPPLY

DISCONNECT
SIZE

MCA

MOCP*

FLA

94 /93
106/105
101/ 99
112/111
108/106
120/118
117/113
129/125
94/ 93
106/108
101/100
112/115
108/109
120/124
117/116
129/131
150/138
164/153
157/145
172/160
167/154
181/169
175/161
190/176
94/ 93
106/105
101/ 99
112/111
108/106
120/118
117/113
129/125
45
52
48
54
52
58
55
62
47
55
51
59
55
63
59
67
70
78
73
81
78
85
81
89
100
108
103
111
108
115
111
119

100/100
125/125
110/100
125/125
125/125
125/125
125/125
150/150
100/100
125/125
110/110
125/125
125/125
125/125
125/125
150/150
150/150
175/175
175/150
175/175
175/175
200/175
175/175
200/200
100/100
125/125
110/100
125/125
125/125
125/125
125/125
150/150
50
60
50
60
60
60
60
70
50
60
60
60
60
70
60
70
80
80
80
90
80
90
90
100
110
125
125
125
125
125
125
125

102/101
116/115
109/107
123/121
118/115
131/129
125/122
139/136
102/101
116/115
109/107
123/121
118/115
131/129
125/122
139/136
138/155
151/168
145/161
158/175
153/169
167/183
161/176
174/190
102/101
116/115
109/107
123/121
118/115
131/129
125/122
139/136
49
56
52
59
56
63
60
67
49
56
52
59
56
63
60
67
78
85
81
88
85
92
89
96
112
120
116
123
120
127
123
130

ELECTRICAL DATA 50HJ020-028 WITH OPTIONAL CONVENIENCE OUTLET (cont)


UNIT
SIZE
50HJ

NOMINAL
VOLTAGE
(3 Ph, 60 Hz)

VOLTAGE
RANGE
Min

COMPRESSOR
No. 2

No. 1

Max

RLA

LRA

RLA

LRA

RLA

ELECTRIC
HEAT

OFM

No. 3
LRA

Qty

Hp

FLA
(ea)

kW

FLA

575

518

633

9.3

73

9.3

73

9.3

73

0.25

Hp

24.8

024

IFM

24

FLA

6.1

7.5

10

11

6.1

7.5

10

11

6.1

7.5

10

11

6.1

7.5

10

11

0.7

48.3

46

78

75

POWER
EXHAUST
Qty Hp FLA
(ea)

2
1
2.4

2
1
2.4

2
1
2.4

2
1
2.4

2
1
2.4

2
1
2.4

2
1
2.4

2
1
2.4

2
1
2.4

2
1
2.4

2
1
2.4

2
1
2.4

POWER
SUPPLY

DISCONNECT
SIZE

MCA

MOCP*

FLA

42
47
45
50
47
52
42
47
45
51
48
54
69
75
73
79
75
81
86
92
90
96
93
99

50
50
50
50
50
60
50
50
50
60
50
60
70
80
80
80
80
90
100
100
100
100
100
100

46
51
49
55
51
57
46
51
49
55
51
57
63
69
67
72
69
75
97
102
100
106
102
108

ELECTRIC HEAT BRANCH CIRCUIT 208/240 75-kW ELECTRIC HEAT


VOLTAGE
RANGE

COMPRESSOR
No. 2

NOMINAL
VOLTAGE
(3 Ph, 60 Hz)

Min

Max

RLA

LRA

RLA

LRA

RLA

LRA

Qty

Hp

024

208/240

187

253

No. 1

ELECTRIC
HEAT

OFM

UNIT
SIZE
50HJ

No. 3

FLA
(ea)

IFM

kW

FLA

Hp

FLA

56/75

156/180

POWER
EXHAUST
Qty Hp FLA
(ea)

POWER
SUPPLY

DISCONNECT
SIZE

MCA

MOCP*

FLA

156/180

175/200

179/207

FEEDER CIRCUIT FOR 208/230 UNIT WITH 75-kW ELECTRIC HEAT


UNIT
SIZE
50HJ

024

NOMINAL
VOLTAGE
(3 Ph, 60 Hz)

208/230

VOLTAGE
RANGE
Min

187

Max

253

No. 1
RLA

LRA

22.4

FLA Full Load Amps


HACR Heating, Air Conditioning and
Refrigeration
IFM
Indoor (Evaporator) Fan Motor
LRA Locked Rotor Amps

COMPRESSOR
No. 2

184

RLA

22.4

LEGEND
MCA
MOCP
NEC
OFM
RLA

LRA

184

RLA

22.4

LRA

184

Qty

Hp

0.25

Minimum Circuit Amps


Maximum Overcurrent Protection
National Electrical Code
Outdoor (Condenser) Fan Motor
Rated Load Amps

*Fuse or HACR circuit breaker.


208/230 v 75-kW Electric Heat units must use dual-point wiring. The main table lists the
branch circuit values for the refrigeration part of the system. The following two tables list the
branch circuit values for the electric heat and values for a feeder circuit for both branch circuits.

Average Voltage =

FLA
(ea)

1.5

kW

56/75

FLA

IFM
Hp

FLA

3.7

10.6/9.6

16.7/15.2

7.5

24.2/22

10

30.8/28

156/180

POWER
EXHAUST
Qty Hp FLA
(ea)

2
1
5.9

2
1
5.9

2
1
5.9

2
1
5.9

POWER
SUPPLY

DISCONNECT
SIZE

MCA

MOCP*

FLA

176/198
190/213
183/205
198/220
193/214
207/229
201/221
216/236

200/225
200/225
200/225
200/225
200/225
225/250
225/225
225/250

197/224
211/237
204/230
218/244
213/238
227/252
221/245
234/259

Determine maximum deviation from average voltage.


(AB) 457 452 = 5 v
(BC) 464 457 = 7 v
(AC) 457 455 = 2 v
Maximum deviation is 7 v.
Determine percent of voltage imbalance.
7
% Voltage Imbalance = 100 x 457
= 1.53%
This amount of phase imbalance is satisfactory as it is below the maximum allowable 2%.
IMPORTANT: If the supply voltage phase imbalance is more than 2%, contact your
local electric utility company immediately.
3. The 75-kW 208/240-v electric heat can be factory installed but it must be wired separately in
the field.
4. The convenience outlet full load amps (FLA) are 5, 3 and 3 for 208/230, 460, 575-v units,
respectively.
5. The FLA load amps provided in the table for electric heaters are based on 208/240, 480 and
600 v.
6. MCA calculation for 50HJ units with electric heaters over 50 kW is = 1.25 x (IFM + Power
Exhaust + Convenience Outlet FLA amps) + 1.00 x (Electric Heater FLA).

452 + 464 + 455


3

1371
3
= 457
=

249

50HJ

NOTES:
1. In compliance with NEC requirements for multimotor and combination load equipment (refer
to NEC Articles 430 and 440), the overcurrent protective device for the unit shall be fuse or
HACR breaker. Canadian units may be fuse or circuit breaker.
2. Unbalanced 3-Phase Supply Voltage
Never operate a motor where a phase imbalance in supply voltage is greater than 2%. Use
the following formula to determine the percent of voltage imbalance.
% Voltage Imbalance
max voltage deviation from average voltage
= 100 x
average voltage
Example: Supply voltage is 460-3-60.
AB = 452 v
BC = 464 v
AC = 455 v

ELECTRIC
HEAT

OFM

No. 3

Electrical data 50HJ (cont)


ELECTRICAL DATA 50HJ020-028 WITH OPTIONAL CONVENIENCE OUTLET (cont)
UNIT
SIZE
50HJ

NOMINAL
VOLTAGE
(3 Ph, 60 Hz)

VOLTAGE
RANGE
Min

Max

No. 1
RLA

COMPRESSOR
No. 2

LRA

RLA

LRA

RLA

LRA

ELECTRIC
HEAT

OFM

No. 3
Qty

Hp

FLA
(ea)

kW

FLA

19/25

208/230

187

253

47.1

245

47.1

245

0.25

52/60

IFM
Hp

FLA

16.7/15.2

7.5

24.2/22

10

30.8/28

16.7/15.2

7.5

24.2/22

10

30.8/28

16.7/15.2

7.5

24.2/22

10

30.8/28

16.7/15.2

7.5

24.2/22

10

30.8/28

7.6

7.5

11

10

14

7.6

7.5

11

10

14

7.6

7.5

11

10

14

7.6

7.5

11

10

14

1.5

38/50

104/120

56/75

156/180

028

25

460

414

506

19.6

125

19.6

125

0.25

75

LEGEND
MCA
MOCP
NEC
OFM
RLA

Minimum Circuit Amps


Maximum Overcurrent Protection
National Electrical Code
Outdoor (Condenser) Fan Motor
Rated Load Amps

50HJ

*Fuse or HACR circuit breaker.


208/230 v 75-kW Electric Heat units must use dual-point wiring. The main table lists the
branch circuit values for the refrigeration part of the system. The following two tables list the
branch circuit values for the electric heat and values for a feeder circuit for both branch circuits.
NOTES:
1. In compliance with NEC requirements for multimotor and combination load equipment (refer
to NEC Articles 430 and 440), the overcurrent protective device for the unit shall be fuse or
HACR breaker. Canadian units may be fuse or circuit breaker.
2. Unbalanced 3-Phase Supply Voltage
Never operate a motor where a phase imbalance in supply voltage is greater than 2%. Use
the following formula to determine the percent of voltage imbalance.
% Voltage Imbalance
= 100 x

max voltage deviation from average voltage


average voltage

Example: Supply voltage is 460-3-60.


AB = 452 v
BC = 464 v
AC = 455 v
Average Voltage =

452 + 464 + 455


3

1371
3
= 457
=

250

30

0.7

50

FLA Full Load Amps


HACR Heating, Air Conditioning and
Refrigeration
IFM
Indoor (Evaporator) Fan Motor
LRA Locked Rotor Amps

60

90

POWER
EXHAUST
Qty Hp FLA
(ea)

2
1
5.9

2
1
5.9

2
1
5.9

2
1
5.9

2
1
5.9

2
1
5.9

2
1
5.9

2
1
5.9

2
1
5.9

2
1
5.9

2
1
5.9

2
1
5.9

2
1
3.1

2
1
3.1

2
1
3.1

2
1
3.1

2
1
3.1

2
1
3.1

2
1
3.1

2
1
3.1

2
1
3.1

2
1
3.1

2
1
3.1

2
1
3.1

POWER
SUPPLY

DISCONNECT
SIZE

MCA

MOCP*

FLA

137/135
148/147
144/142
156/154
151/148
163/160
137/135
148/147
144/142
156/154
151/148
163/160
157/145
172/160
167/154
181/169
175/161
190/176
137/135
148/147
144/142
156/154
151/148
163/160
59
65
62
69
65
72
59
65
62
69
65
72
73
81
78
85
81
89
103
111
108
115
111
119

175/175
175/175
175/175
200/200
175/175
200/200
175/175
175/175
175/175
200/200
175/175
200/200
175/175
175/175
175/175
200/200
175/175
200/200
175/175
175/175
175/175
200/200
175/175
200/200
60
80
80
80
80
90
60
80
80
80
80
90
80
90
80
90
90
100
125
125
125
125
125
125

144/142
157/155
152/150
166/163
160/157
173/170
144/142
157/155
152/150
166/163
160/157
173/170
145/161
158/175
153/169
167/183
161/176
174/190
144/142
157/155
152/150
166/163
160/157
173/170
62
69
66
73
69
77
62
69
66
73
69
77
81
88
85
92
89
96
116
123
120
127
123
130

Determine maximum deviation from average voltage.


(AB) 457 452 = 5 v
(BC) 464 457 = 7 v
(AC) 457 455 = 2 v
Maximum deviation is 7 v.
Determine percent of voltage imbalance.
7
% Voltage Imbalance = 100 x 457
= 1.53%
This amount of phase imbalance is satisfactory as it is below the maximum allowable 2%.
IMPORTANT: If the supply voltage phase imbalance is more than 2%, contact your
local electric utility company immediately.
3. The 75-kW 208/240-v electric heat can be factory installed but it must be wired separately in
the field.
4. The convenience outlet full load amps (FLA) are 5, 3 and 3 for 208/230, 460, 575-v units,
respectively.
5. The FLA load amps provided in the table for electric heaters are based on 208/240, 480 and
600 v.
6. MCA calculation for 50HJ units with electric heaters over 50 kW is = 1.25 x (IFM + Power
Exhaust + Convenience Outlet FLA amps) + 1.00 x (Electric Heater FLA).

ELECTRICAL DATA 50HJ020-028 WITH OPTIONAL CONVENIENCE OUTLET (cont)


UNIT
SIZE
50HJ

NOMINAL
VOLTAGE
(3 Ph, 60 Hz)

VOLTAGE
RANGE
Min

COMPRESSOR
No. 2

No. 1

Max

RLA

LRA

RLA

LRA

RLA

ELECTRIC
HEAT

OFM

No. 3
LRA

Qty

Hp

FLA
(ea)

kW

FLA

575

518

633

15.8

100

15.8

100

0.25

Hp

24.8

028

IFM

24

FLA

6.1

7.5

10

11

6.1

7.5

10

11

6.1

7.5

10

11

6.1

7.5

10

11

0.7

48.3

46

78

75

POWER
EXHAUST
Qty Hp FLA
(ea)

2
1
2.4

2
1
2.4

2
1
2.4

2
1
2.4

2
1
2.4

2
1
2.4

2
1
2.4

2
1
2.4

2
1
2.4

2
1
2.4

2
1
2.4

2
1
2.4

POWER
SUPPLY

DISCONNECT
SIZE

MCA

MOCP*

FLA

49
54
52
57
54
59
49
54
52
57
54
59
69
75
73
79
75
81
86
92
90
96
93
99

60
60
60
60
60
60
60
60
60
60
60
60
70
80
80
80
80
90
100
100
100
100
100
100

52
57
55
60
57
63
52
57
55
60
57
63
63
69
67
72
69
75
97
102
100
106
102
108

ELECTRIC HEAT BRANCH CIRCUIT 208/240 75-kW ELECTRIC HEAT


VOLTAGE
RANGE

COMPRESSOR
No. 2

NOMINAL
VOLTAGE
(3 Ph, 60 Hz)

Min

Max

RLA

LRA

RLA

LRA

RLA

LRA

Qty

Hp

028

208/240

187

253

No. 1

ELECTRIC
HEAT

OFM

UNIT
SIZE
50HJ

No. 3

FLA
(ea)

IFM

kW

FLA

Hp

FLA

56/75

156/180

POWER
EXHAUST
Qty Hp FLA
(ea)

POWER
SUPPLY

DISCONNECT
SIZE

MCA

MOCP*

FLA

156/180

175/200

179/207

FEEDER CIRCUIT FOR 208/230 UNIT WITH 75-kW ELECTRIC HEAT


UNIT
SIZE
50HJ

NOMINAL
VOLTAGE
(3 Ph, 60 Hz)

028

208/230

VOLTAGE
RANGE
Min

187

Max

253

No. 1
RLA

LRA

47.1

FLA Full Load Amps


HACR Heating, Air Conditioning and
Refrigeration
IFM
Indoor (Evaporator) Fan Motor
LRA Locked Rotor Amps

COMPRESSOR
No. 2

245

RLA

47.1

LEGEND
MCA
MOCP
NEC
OFM
RLA

LRA

245

RLA

LRA

Qty

Hp

0.25

Minimum Circuit Amps


Maximum Overcurrent Protection
National Electrical Code
Outdoor (Condenser) Fan Motor
Rated Load Amps

*Fuse or HACR circuit breaker.


208/230 v 75-kW Electric Heat units must use dual-point wiring. The main table lists the
branch circuit values for the refrigeration part of the system. The following two tables list the
branch circuit values for the electric heat and values for a feeder circuit for both branch circuits.
NOTES:
1. In compliance with NEC requirements for multimotor and combination load equipment (refer
to NEC Articles 430 and 440), the overcurrent protective device for the unit shall be fuse or
HACR breaker. Canadian units may be fuse or circuit breaker.
2. Unbalanced 3-Phase Supply Voltage
Never operate a motor where a phase imbalance in supply voltage is greater than 2%. Use
the following formula to determine the percent of voltage imbalance.
% Voltage Imbalance
max voltage deviation from average voltage
average voltage

Example: Supply voltage is 460-3-60.


AB = 452 v
BC = 464 v
AC = 455 v
Average Voltage =

FLA
(ea)

1.5

kW

56/75

FLA

156/180

IFM
Hp

FLA

16.7/15.2

7.5

24.2/22

10

30.8/28

POWER
EXHAUST
Qty Hp FLA
(ea)

2
1
5.9

2
1
5.9

2
1
5.9

POWER
SUPPLY

DISCONNECT
SIZE

MCA

MOCP*

FLA

183/205
198/220
193/214
207/229
201/221
216/236

200/225
200/225
200/225
225/250
225/225
225/250

204/230
218/244
213/238
227/252
221/245
234/259

Determine maximum deviation from average voltage.


(AB) 457 452 = 5 v
(BC) 464 457 = 7 v
(AC) 457 455 = 2 v
Maximum deviation is 7 v.
Determine percent of voltage imbalance.
7
% Voltage Imbalance = 100 x 457
= 1.53%
This amount of phase imbalance is satisfactory as it is below the maximum allowable 2%.
IMPORTANT: If the supply voltage phase imbalance is more than 2%, contact your
local electric utility company immediately.
3. The 75-kW 208/240-v electric heat can be factory installed but it must be wired separately in
the field.
4. The convenience outlet full load amps (FLA) are 5, 3 and 3 for 208/230, 460, 575-v units,
respectively.
5. The FLA load amps provided in the table for electric heaters are based on 208/240, 480 and
600 v.
6. MCA calculation for 50HJ units with electric heaters over 50 kW is = 1.25 x (IFM + Power
Exhaust + Convenience Outlet FLA amps) + 1.00 x (Electric Heater FLA).

452 + 464 + 455


3

1371
3
= 457
=

251

50HJ

= 100 x

ELECTRIC
HEAT

OFM

No. 3

Typical wiring schematics 50HJ


50HJ004-014 (50HJ007 Shown)

50HJ

LEGEND AND NOTES FOR 50HJ004-017 TYPICAL WIRING SCHEMATICS


AHA
AWG
C
CAP
CB
CC
CH
CLO
COMP
EQUIP
FL
FPT
FU
GND
HC
HPS
HTR
IFC
IFCB
IFM
IFR
IRH
LS
LPS
LSM
OAT
OFC
OFM

252

Adjustable Heat Anticipator


American Wire Gage
Contactor, Compressor
Capacitor
Circuit Breaker
Cooling Compensator
Crankcase Heater
Compressor Lockout
Compressor Motor
Equipment
Fuse Link
Freeze Protection Thermostat
Fuse
Ground
Heater Contactor
High-Pressure Switch
Heater
Indoor (Evaporator) Fan Contactor
Indoor Fan Circuit Breaker
Indoor (Evaporator) Fan Motor
Indoor (Evaporator) Fan Relay
Indoor/Return Relative Humidity
Limit Switch
Low-Pressure Switch
Limit Switch (Manual Reset)
Outdoor-Air Thermostat
Outdoor (Condenser) Fan Contactor
Outdoor (Condenser) Fan Motor

OLR
OP
ORH
P
PL
QT
RAT
SAT
TB
TC
TH
TRAN

Overload Relay
Overcurrent Protection
Outdoor Relative Humidity
Plug
Plug Assembly
Quadruple Terminal
Return Air Temperature Sensor
Supply-Air Thermostat
Terminal Block
Thermostat-Cooling
Thermostat-Heating
Transformer
Field Splice
Marked Wire
Terminal (Marked)
Terminal (Unmarked)
Terminal Block
Splice
Splice (Marked)
Factory Wiring
Field Control Wiring

Field Power Wiring


Accessory or Optional Wiring
To indicate common potential only. Not to represent wiring.

NOTES 50HJ004-014 Wiring Diagram:


1. If any of the original wire furnished must be replaced, it must be replaced with
type 90 C wire or its equivalent.
2. Three-phase motors are protected under primary single-phasing conditions.
5. Use copper conductors only.
6. Use copper, copper clad aluminum or aluminum conductors.
NOTES 50HJ015,017 Wiring Diagram:
1. Compressor and/or fan motor(s) thermally protected; three-phase motors
protected against primary single phasing conditions.
2. If any of the original wire furnished must be replaced, it must be replaced with
type 90 C or its equivalent.
3. Jumpers are omitted when unit is equipped with economizer.
4. IFCB Must Trip Amps is equal to or less than 140% FLA.
5. On TRAN1 use BLK lead for 460-v power supply and ORN lead for 575-v
power supply.
6. The CLO locks out the compressor to prevent short cycling on compressor
overload and safety devices; before replacing CLO, check these devices.
7. Number(s) indicates the line location of used contacts. A bracket over (2)
numbers signifies a single pole, double throw contact. An underlined number
signifies a normally closed contact. Plain (no line) number signifies a normally open contact.

50HJ015,017

50HJ
253

Typical wiring schematics 50HJ (cont)

50HJ

LOW VOLTAGE CONTROL SCHEMATIC 50HJ020-028

254

905

POWER SCHEMATIC 50HJ020-028

50HJ

905

255

256

905

---A
AUX
AL
---B
---C
C
CAP
CB
CCH
CLO
COMP
CR
ECB
FCS
FIOP
FPT
HACR

HPS
IAQ
IFC
IFCB
IFM
LPS

Circuit A
Auxiliary Contact
Ambient Limit
Circuit B
Circuit C
Compressor, Contactor
Capacitor
Circuit Breaker
Crankcase Heater
Compressor Lockout
Compressor
Control Relay
Economizer Control Board
Fan Cycling Switch
Factory-Installed Option
Freeze Protect Thermostat
Heating, Air Conditioning,
and Refrigeration
High-Pressure Switch
Indoor Air Quality
Indoor Fan Contactor
Indoor Fan Circuit Breaker
Indoor Fan Motor
Low-Pressure Switch
OAT
OFC
OFM
PEC
PEM
PL
SAT
TB
TRAN

LEGEND

50HJ

Field Wiring
To indicate common potential
only. Not to represent wiring.
To indicate FIOP or Accessory

Terminal (Marked)
Splice
Factory Wiring

Terminal (Unmarked)

Terminal Block

Outdoor Air Temperature


Outdoor Fan Contactor
Outdoor Fan Motor
Power Exhaust Contactor
Power Exhaust Motor
Plug
Supply-Air Temperature
Terminal Block
Transformer
BM
C
CM
CS
G
IFO
L1
R
RT
SS
W
W1
W2
X
Y1
Y2

THERMOSTAT MARKINGS
Blower Motor
Common
Combustion Motor
Centrifugal Switch
Fan
Indoor Fan On
Line 1
Thermostat Power
Power Supply
Speed Sensor
Thermostat Heat
1st Stage of Heating
2nd Stage of Heating
Alarm Output
1st Stage of Cooling
2nd Stage of Cooling

NOTES:
1. Factory wiring is in accordance with the National Electrical Codes. Any field modifications or additions must be in compliance with all applicable codes.
2. Use 75 C min wire for field power supply. Use copper wires for all units.
3. All circuit breakers Must Trip Amps are equal to or less than 156% RLA.
4. Compressor and fan motors are thermally protected. Three-phase motors protected
against primary single-phase conditions.
5. The CLO locks out the compressor to prevent short cycling on compressor overload
and safety devices. Before replacing CLO, check these devices.

COMPONENT ARRANGEMENT 50HJ020-028

Typical wiring schematics 50HJ (cont)

ECONOMI$ER IV WIRING 50HJ004-014 UNITS

LEGEND
IAQ Indoor Air Quality
LA Low Ambient Lockout Device
POT Potentiometer
OAT Outdoor-Air Temperature
RAT Return-Air Temperature

NOTE:
Potentiometer Defaults Settings:
Power Exhaust Middle
Minimum Pos.
Fully Closed
DCV Max.
Middle
DCV Set
Middle
Enthalpy
C Setting

NOTES:
1. 620 ohm, 1 watt 5% resister should be removed only when using differential enthalpy or dry bulb.
2. If a separate field-supplied 24v transformer is used for the IAQ sensor
power supply, it cannot have the secondary of the transformer grounded.
3. For field-installed remote minimum position POT, remove black wire jumper
between P and P1 and set control minimum position POT to the minimum
position.

ECONOMI$ER IV WIRING 50HJ015,017 UNITS

50HJ

AL
ECB
IA
IAQ

Ambient Limit
Economizer Control Board
Indoor Air
Indoor Air Quality

LEGEND
OA
OAS
RAS
SAT

905

Outdoor Air
Outdoor Air Sensor
Return Air Sensor
Supply Air Temperature

257

Typical wiring schematics 50HJ (cont)


ECONOMI$ER2 WIRING 50HJ004-014 UNITS
BLACK

4
3
5

BLUE
500 OHM
RESISTOR

8
VIOLET

NOTE 1
PINK

RUN
RED

NOTE 3

YELLOW

10

50HJ540573
ACTUATOR
ASSEMBLY

OPTIONAL CO 2
SENSOR 4 - 20 mA
OUTPUT

11
9
WHITE

DIRECT DRIVE
ACTUATOR

12

ECONOMISER2 PLUG
NOTES:
1. Switch on actuator must be in run position for economizer to operate.
2. PremierLink control requires that the standard 50HJ540569 outside-air sensor be replaced by either the CROASENR001A00 dry bulb sensor or HH57A077
enthalpy sensor.
3. 50HJ540573 actuator consists of the 50HJ540567 actuator and a harness with 500-ohm resistor.

ECONOMI$ER2 WIRING 50HJ015,017 UNITS


4
3
7
RED
500 OHM
RESISTOR

8
PINK

NOTE 1
BLUE

RUN

OAT
BLACK

NOTE 2

50HJ

1
10

50HJ540573
ACTUATOR
ASSEMBLY

11
9
DIRECT DRIVE
ACTUATOR

LEGEND
OAT Outdoor Air Temperature Sensor
NOTES:
1. Switch on actuator must be in run position for economizer to operate.
2. 50HJ540573 actuator consists of the 50HJ540567 actuator and a harness with 500-ohm resistor.

258

WHITE

12

ECONOMISER2 PLUG

CONVENIENCE OUTLET (OPTIONAL) 50HJ004-014


460V
C2 FOR 008-014 UNITS

RED

YEL BLU

LINE SIDE

GRA

C
H3

H1

H2

H4

TRAN4

BLU
GRA

11

21

RED
YEL

13

23

23

240V
X4

X2

X1

X3

RED

SECONDARY
120V

H1

YEL BLU
H3

H2

X2

X3

GRA
208-230-1 ONLY

H4

TRAN4

RED

GRA

X4

600V
H2

H1

X1

BLK

WHT
SECONDARY
120V

TRAN4

X4

X2

GROUND FAULT
INTERRUPTER
CONVENIENCE
OUTLET
GFI - CO

X1

X3

GRN-YEL
GRN-YEL

SECONDARY
120V
SWITCH

BLK

FUSE

TEST
RESET

WHT

15 AMP

NON-FUSED DISCONNECT (OPTIONAL) 50HJ004-014


UNIT
DISCONNECT
FIELD
POWER
SUPPLY

BLK

BLK

YEL

YEL

BLU

BLU

BLK

YEL

YEL

BLU

BLU

50HJ

TB
BLK

SINGLE POINT CONNECTION BOX

NOTE: Use copper conductors only.

259

Typical wiring schematics 50HJ (cont)


NON-FUSED DISCONNECT (OPTIONAL) 50HJ015,017

50HJ

NOTES:
1. If the Non-Fused Disconnect Service Option is ordered for size 015 and 017 units, the Non-Fused Disconnect will be factory-installed.
2. The Disconnect takes the place of TB-1 as shown on the unit wiring diagram label and the component arrangement label.

260

COBRA ENERGY RECOVERY UNIT CONTROL WIRING WITH THERMIDISTAT AND STANDARD CONTROLS
BASE UNIT
CONNECTION
BOARD

CONNECTION
BOARD

R
Y1

HM
OC

Y2
W1

T STAT

W2
W1

W2
G
C

W2

UNIT

W1

CONTROL BOX

HM

CONTROL
BOX
ROOFTOP UNIT
SECTION

HM

ENERGY
RECOVERY
SECTION

THERMIDISTAT/
THERMOSTAT
CONNECTION
BOARD
R
C
Y1
Y2
G
W1
W2
OC
DEHUM

50HJ

LIGHT COMMERCIAL THERMIDISTAT DEVICE

261

Typical wiring schematics 50HJ (cont)


COBRA ENERGY RECOVERY UNIT CONTROL WIRING WITH HUMIDISTAT, SPACE TEMPERATURE SENSOR,
CO2 SENSOR, AND PREMIERLINK CONTROLS
TB2
1
2
3
4
5
6
7
8

BLU
BRN
BLK

COM
4-20mA

TB1
HM
OC
W2

R
Y1
Y2
W1

T STAT

W1

W2
G
C

W2

UNIT

W1

CONTROL BOX
TB3

TB2

HM

TB1

CONTROL
BOX

PREMIERLINK
CONTROLS

ROOFTOP UNIT
SECTION

HM

ENERGY
RECOVERY
SECTION

HM
R

HUMIDISTAT

SEN
SW1

6
RED(+)
WHT(GND)
BLK(-)

SET

BLK
(T56)
BRN (GND)
BLU (SPT)

50HJ

CCN COM

JUMPER
TERMINALS
AS SHOWN

Cool

ALARM
NC
COM RELAY
NO CONTACTS

H G 24 VAC
OR
+ - 24 VDC

2 1

8765432 1

Warm

SPACE TEMPERATURE SENSOR


(33ZCT56SPT)

262

+ 0-10VDC
- SIG COM
+ 4-20mA

SENSOR WIRING

INDOOR AIR QUALITY (CO 2 ) SENSOR


(33ZCSENCO2)

Typical piping and wiring 50HJ004-014


VERTICAL DISCHARGE DUCTING

HORIZONTAL DISCHARGE DUCTING

50HJ
LEGEND
NEC National Electrical Code
*Factory-supplied, internally mounted disconnect
available as an option.

263

Typical piping and wiring 50HJ015, 017


(50HJ015 shown)

LEGEND
NEC National Electrical Code

50HJ

NOTES:
1. Illustration shown is a general guide only and is not intended to include all details for any specific installation.
2. Installation must comply with all applicable codes.
3. A 90-degree elbow must be installed on the supply ductwork below the unit discharge for units equipped with electric heat.

264

Guide specifications 50HJ004-014


Packaged Rooftop Electric Cooling Unit
Constant Volume Application
HVAC Guide Specifications
Size Range: 3 to 121/2 Tons, Nominal (Cooling)
4.4 to 51 kW, Nominal
(Accessory Electric Heating)
Carrier Model
Numbers:
50HJ

SIZES 004 TO 012


ARE ENERGY STAR
QUALIFIED

265

50HJ

Part 1 General
1.01 SYSTEM DESCRIPTION
Outdoor rooftop mounted, electrically controlled
heating and cooling unit utilizing a hermetic compressor(s) for cooling duty. Unit shall discharge supply air vertically or horizontally as shown on contract
drawings.
1.02 QUALITY ASSURANCE
A. Unit shall well exceed ASHRAE 90.1-2001 Energy
Standards. Units 004 to 012 are Energy Star
qualified.
B. Unit shall be rated in accordance with ARI
Standards 210 or 360. Designed in accordance with
UL Standard 1995.
C. Unit shall be designed to conform to ASHRAE 15,
latest revision.
D. Unit shall be UL-tested and certified in accordance
with ANSI Z21.47 Standards and UL-listed and
certified under Canadian standards as a total package for safety requirements.
E. Roof curb shall be designed to conform to NRCA
Standards.
F. Insulation and adhesive shall meet NFPA 90A
requirements for flame spread and smoke
generation.
G. Unit casing shall be capable of withstanding
500-hour salt spray exposure per ASTM B117
(scribed specimen).
H. Unit shall be designed in accordance with
ISO 9001:2000, and shall be manufactured in a
facility registered to ISO 9001:2000.
I. Each unit shall be subjected to a completely automated run testing on the assembly line. Units
contain a factory-supplied printout indicating tested
pressures, amperages, data, and inspectors; providing certification of the unit status at the time of
manufacture.
1.03 DELIVERY, STORAGE, AND HANDLING
Unit shall be stored and handled per manufacturers
recommendations.

Part 2 Products
2.01 EQUIPMENT (STANDARD)
A. General:
Factory assembled, single-piece heating and cooling
unit. Contained within the unit enclosure shall be all
factory wiring, piping, controls, refrigerant charge
(R-22), and special features required prior to field
start-up.
B. Unit Cabinet:
1. Unit cabinet shall be constructed of galvanized
steel, and shall be bonderized and coated with a
prepainted baked enamel finish on all externally
exposed surfaces.
2. Evaporator fan compartment interior cabinet
surfaces shall be insulated with a minimum
1/ -in. thick, 1 lb density, flexible fiberglass
2
insulation, neoprene coated on the air side.
3. Cabinet panels shall be easily removable for
servicing.
4. Holes shall be provided in the base rails for rigging shackles to facilitate maneuvering and
overhead rigging.
5. Unit shall have a factory-installed, sloped condensate drain pan made of a non-corrosive
material, providing a minimum 3/4-in.-14 NPT.
connection with both vertical and horizontal
drains, and shall comply with ASHRAE
Standard 62.
6. Unit shall have a factory-installed filter access
panel to provide filter access with tool-less
removal.
7. Unit shall have standard thru-the-bottom power
connection capability (accessory kit is required).
C. Fans:
1. Evaporator Fan:
a. Fan shall be direct or belt driven as shown
on the equipment drawings. Belt drive shall
include an adjustable-pitch motor pulley.
b. Fan wheel shall be double-inlet type with
forward-curved blades.
c. Bearings shall be sealed, permanently lubricated ball-bearing type for longer life and
lower maintenance.
2. Evaporator fan shall be made from steel with a
corrosion-resistant finish and shall be dynamically balanced.
3. Condenser fan shall be of the direct-driven (with
totally enclosed motors) propeller type and shall
discharge air vertically.
4. Condenser fan shall have aluminum blades riveted to corrosion-resistant steel spiders and
shall be dynamically balanced.

50HJ

Guide specifications 50HJ004-014 (cont)


D. Compressor(s):
1. Fully hermetic type, internally protected
scroll-type.
2. Factory mounted on rubber grommets and
internally spring mounted for vibration
isolation.
3. On dual electrically and mechanically independent circuits (008-014).
E. Coils:
1. Standard evaporator and condenser coils shall
have aluminum lanced plate fins mechanically
bonded to seamless internally grooved copper
tubes with all joints brazed.
2. Dual compressor models (008-014), evaporator
coils are face-split design (circuit no. 1 on
bottom).
3. Testing:
a. Evaporator and condenser coils shall be
qualified to UL 1995 burst test at 2,200 psi.
b. Evaporator and condenser coils shall be leak
tested to 150 psig and pressure tested to
400 psig.
4. Optional Coils:
a. Optional pre-coated aluminum-fin coils shall
have a durable epoxy-phenolic coating to
provide protection in mildly corrosive coastal
environments. Coating shall be applied to
the aluminum fin stock prior to the fin
stamping process to create an inert barrier
between the aluminum fin and copper tube.
Epoxy-phenolic barrier shall minimize galvanic action between dissimilar metals.
b. Copper-fin coils shall be constructed of copper fins mechanically bonded to copper
tubes and copper tube sheets. Galvanized
steel tube sheets shall not be acceptable. A
polymer strip shall prevent coil assembly
from contacting the sheet metal coil pan to
minimize potential for galvanic corrosion
between coil and pan. All copper construction shall provide protection in moderate
coastal environments.
c. E-Coated aluminum-fin coils shall have a
flexible epoxy polymer coating uniformly
applied to all coil surface areas without material bridging between fins. Coating process
shall ensure complete coil encapsulation.
Color shall be high gloss black with gloss
60 deg of 65 to 90% per ASTM D523-89.
Uniform dry film thickness from 0.8 to
1.2 mil on all surface areas including fin
edges. Superior hardness characteristics of
2H per ASTM D3363-92A and cross-hatch
adhesion of 4B-5B per ASTM D3359-93.
Impact resistance shall be up to 160 in.-lb
(ASTM D2794-93). Humidity and water
immersion resistance shall be up to minimum 1000 and 250 hours respectively
266

(ASTM D2247-92 and ASTM D870-92).


Corrosion durability shall be confirmed
through testing to be no less than
1000 hours salt spray per ASTM B117-90.
Coil construction shall be aluminum fins
mechanically bonded to copper tubes.
d. E-Coated copper-fin coils shall have a flexible epoxy polymer coating uniformly applied
to all coil surface areas without material
bridging between fins. Coating process shall
ensure complete coil encapsulation. Color
shall be high gloss black with gloss 60 deg
of 65 to 90% per ASTM D523-89. Uniform
dry film thickness from 0.8 to 1.2 mil on all
surface areas including fin edges. Superior
hardness characteristics of 2H per
ASTM D3363-92A and cross-hatch adhesion of 4B-5B per ASTM D3359-93.
Impact resistance shall be up to 160 in.-lb
(ASTM D2794-93). Humidity and water
immersion resistance shall be up to
minimum 1000 and 250 hours respectively
(ASTM D2247-92 and ASTM D870-92).
Corrosion durability shall be confirmed
through testing to be no less than
1000 hours salt spray per ASTM B117-90.
Coil construction shall be copper fins
mechanically bonded to copper tubes with
copper tube sheets. Galvanized steel tube
sheets shall not be acceptable. A polymer
strip shall prevent coil assembly from contacting sheet metal coil pan to maintain
coating integrity and minimize corrosion
potential between coil and pan.
F. Refrigerant Components:
Refrigerant circuit components shall include:
1. Fixed orifice metering system (Acutrol device).
2. Refrigerant filter drier.
3. Service gage connections on suction, discharge,
and liquid lines.
G. Filter Section:
1. Standard filter section shall consist of factoryinstalled, low velocity, throwaway 2-in. thick
fiberglass filters of commercially available sizes.
2. Filter face velocity shall not exceed 320 fpm at
nominal airflows.
3. Filter section should use only one size filter.
4. Filters shall be accessible through an access
panel with no-tool removal.
H. Controls and Safeties:
1. Unit Controls:
Unit shall be complete with self-contained lowvoltage control circuit protected by a fuse on
the 24-v transformer side (008-014 units have
a resettable circuit breaker).

905

c. Shall be compatible with ComfortLink


controllers.
d. Shall be ASHRAE 62-2001 compliant.
e. Shall accept a CO2 sensor in the conditioned
space Demand Control Ventilation (DCV)
ready.
f. Shall have baud communication rate of
38.4K or faster.
g. Shall be Internet ready.
h. Shall include an integrated economizer
controller.
i. If an economizer is specified the
EconoMi$er2 with the 4 to 20 mA actuator
and no microprocessor control is required.
2. Roof Curbs (Horizontal and Vertical):
a. Formed galvanized steel with wood nailer
strip and shall be capable of supporting
entire unit weight.
b. Permits installation and securing of ductwork
to curb prior to mounting unit on the curb.
3. Integrated Economizers:
a. Integrated integral modulating type capable
of simultaneous economizer and compressor
operation.
b. Available as a factory-installed option in vertical supply/return configuration only. (Available as a field-installed accessory for
dedicated horizontal and/or vertical supply
return configurations.)
c. Includes all hardware and controls to provide
cooling with outdoor air.
d. Equipped with low-leakage dampers, not to
exceed 2% leakage at 1 in. wg pressure
differential.
e. Capable of introducing up to 100% outdoor
air.
f. EconoMi$er IV and EconoMi$er2 shall be
equipped with a barometric relief damper
capable of relieving up to 100% return air.
g. Designed to close damper(s) during loss-ofpower situations with spring return built into
motor.
h. Dry bulb outdoor-air temperature sensor
shall be provided as standard. Outdoor air
sensor set point is adjustable and shall range
from 40 to 100 F. For the EconoMi$er IV,
the return air sensor, indoor enthalpy sensor,
and outdoor enthalpy sensor shall be provided as field-installed accessories to provide
enthalpy control, differential enthalpy control, and differential dry bulb temperature
control. For the EconoMi$er2, the enthalpy,
differential temperature (adjustable), and differential enthalpy control shall be provided
as field-installed accessories.

267

50HJ

2. Safeties:
a. Unit shall incorporate a solid-state compressor protector which provides anti-cycle reset
capability at the space thermostat, should
any of the following standard safety devices
trip and shut off compressor.
1) Compressor overtemperature,
overcurrent.
2) Loss-of-charge/low-pressure switch.
3) Freeze-protection thermostat, evaporator coil.
4) High-pressure switch.
5) Automatic reset motor thermal overload
protector.
The lockout protection shall be easily disconnected at the control board, if necessary.
I. Operating Characteristics:
1. Unit shall be capable of starting and running at
125 F ambient outdoor temperature, meeting
maximum load criteria of ARI Standard 210/
240 or 360 at + 10% voltage.
2. Compressor with standard controls shall be
capable of operation down to 25 F ambient
outdoor temperature.
J. Electrical Requirements:
All unit power wiring shall enter unit cabinet at a single factory-predrilled location.
K. Motors:
1. Compressor motors shall be cooled by refrigerant gas passing through motor windings and
shall have line break thermal and current overload protection.
2. Evaporator-fan motor shall have permanently
lubricated bearings and inherent automaticreset thermal overload protection. Evaporator
motors are designed specifically for Carrier and
do NOT have conventional horsepower (HP)
ratings listed on the motor nameplate. Motors
are designed and qualified in the air-over location downstream of the cooling coil and carry a
maximum continuous bhp rating that is the
maximum application bhp rating for the motor;
no safety factors above that rating may be
applied.
3. Totally enclosed condenser-fan motor shall have
permanently lubricated bearings, and inherent
automatic-reset thermal overload protection.
L. Special Features:
Certain features are not applicable when the features designated * are specified. For assistance in
amending the specifications, contact your local
Carrier Sales Office.
* 1. Carrier PremierLink Controls:
a. Shall be available as a factory-installed or as
a field-installed accessory.
b. Shall work with Carrier Comfort Network
(CCN) and ComfortVIEW software.

Guide specifications 50HJ004-014 (cont)

50HJ

268

i. The EconoMi$er IV and EconoMi$er2 shall


have a gear-driven parallel blade design.
j. EconoMi$er IV microprocessor control shall
provide control of internal building pressure
through its accessory power exhaust function. Factory set at 100%, with a range of
0% to 100%.
k. EconoMi$er2 shall be capable of control
from a 4 to 20 mA signal through optional
4 to 20 mA design without microprocessor
control (required for PremierLink or third
party control interface).
l. EconoMi$er IV Microprocessor Occupied
Minimum Damper Position Setting maintains the minimum airflow into the building
during occupied period providing design
ventilation rate for full occupancy (damper
position during heating). A remote potentiometer may be used to override the set
point.
m. EconoMi$er IV Microprocessor Unoccupied
Minimum Damper Position Setting The
EconoMi$er IV dampers shall be completely
closed when the unit is in the occupied
mode.
n. EconoMi$er IV Microprocessor IAQ/DCV
Maximum Damper Position Setting Setting the maximum position of the damper
prevents the introduction of large amounts
of hot or cold air into the space. The position is intended to satisfy the base minimum
ventilation rate.
o. EconoMi$er IV Microprocessor IAQ/DCV
control modulates the outdoor-air damper to
provide ventilation based on the optional 2
to 10 vdc CO2 sensor input.
p. Compressor lockout sensor (opens at 35 F,
closes at 50 F).
q. Actuator shall be direct coupled to economizer gear, eliminating linkage arms and
rods.
r. Control LEDs:
1) When the outdoor air damper is capable
of providing free cooling, the Free
Cool LED shall illuminate.
2) The IAQ LED indicates when the module is on the DCV mode.
3) The EXH LED indicates when the
exhaust fan contact is closed.
s. Remote Minimum Position Control A
field-installed accessory remote potentiometer allows the outdoor air damper to be
opened or closed beyond the minimum
position in the occupied mode for modified
ventilation.
4. Manual Outdoor-Air Damper:
Manual damper package shall consist of
damper, birdscreen, and rainhood which can be

* 5.

* 6.

* 7.

8.

9.

*10.

11.

905

preset to admit up to 50% outdoor air for year


round ventilation.
100% Two-Position Damper:
a. Two-position damper package shall include
single blade damper and motor. Admits up
to 100% outdoor air.
b. Damper shall close upon indoor (evaporator)
fan shutoff.
c. Designed to close damper during loss of
power situations.
d. Equipped with 15% barometric relief
damper.
25% Two-Position Damper:
a. Two-position damper package shall include
single blade damper and motor. Admits up
to 25% outdoor air.
b. Damper shall close upon indoor (evaporator)
fan shutoff.
Head Pressure Control Package:
Package shall consist of solid-state control and
condenser-coil temperature sensor to maintain
condensing temperature between 90 F and
110 F at outdoor ambient temperatures down
to 20 F by condenser-fan speed modulation or
condenser-fan cycling and wind baffles.
Low Ambient Kit:
When used, kit allows unit to operate at lower
outdoor ambient temperatures down to 20 F.
Electric Resistance Heaters and Single Point
Kits:
a. Open wire nichrome elements with all necessary safety operating controls.
b. UL listed and indicated on basic unit informative plate.
c. Available in multiples to match heating
requirements.
d. Single point kits available for each heater
when required.
Electronic Programmable Thermostat:
Unit shall be capable of using deluxe fullfeatured electronic thermostat. Thermostat
shall use built-in compressor cycle delay control
for both heating and cooling duty. Thermostat
shall be capable of working with Carrier direct
digital controls.
Light Commercial Thermidistat Device:
Field-installed wall-mounted thermostat is used
to control temperature and activation of the
dehumidification package. The Thermidistat
device can be set for humidity settings from
50% to 90% relative humidity. Automatic
humidity control adjusts indoor humidity based
on the outdoor temperature sensor.

905

This factory-installed option or field-installed


accessory shall be available with the following:
a. A mounting kit for the Energy$Recycler unit
for cantilever mounting off of the rooftop
unit with out the use of a slab or a roof curb.
b. A supplementary supply air fan kit to provide increased air movement into the 62AQ
unit.
c. A field-installed 460 v to 208/230 v transformer to provide power when the 208230/1/60 62AQ060 or 100 size
Energy$Recycler unit is used with a 460 v
rooftop unit.
d. An accessory sleeper rail is available for use
with a standard unit roof curb.
e. A field-installed 575 v to 208/230 v
transformer provides power when an
Energy$Recycler unit is used with a 575 v unit.
22. Indoor Air Quality (CO2) Room Sensor
(EconoMi$er IV):
Sensor shall have the ability to provide demand
ventilation control through the EconoMi$er IV.
The IAQ sensor shall be wall mounted with an
LED display in parts per million. The set point
shall have adjustment capability.
23. Return Air CO2 Sensor (EconoMi$er IV):
Sensor shall have the ability to provide demand
ventilation control through the EconoMi$er IV.
The IAQ sensor shall be duct mounted. The set
point shall have adjustment capability.
24. Power Exhaust Accessory for EconoMi$er IV or
EconoMi$er2:
Power exhaust shall be used in conjunction with
EconoMi$er IV or EconoMi$er2 to provide system exhaust of up to 100% of return air (vertical only). The power exhaust is a field-installed
accessory (separate vertical and horizontal
design).
NOTE: Horizontal power exhaust is intended to
mount in return ductwork.
As the outdoor-air damper opens and closes,
both propeller fans are energized and
deenergized through the Economi$er IV controller. The set point is factory set at 100% of
outdoor air, and is adjustable 0 to 100% to
meet specific job requirements. Available in
208/230-1-60 v or 460-3-60 v. An LED light
on the controller indicates when the power
exhaust is operating.
For the EconoMi$er2, the power exhaust shall
be controlled by the PremierLink or third
party controls.

269

50HJ

*12. Thermostat and Subbase:


Thermostat and subbase shall provide staged
cooling and heating automatic (or manual)
changeover, fan control, and indicator light.
*13. Condenser Coil Hail Guard Assembly:
Hail guard shall protect against damage from
hail and flying debris.
14. Unit-Mounted, Non-Fused Disconnect Switch:
Switch shall be factory-installed, internally
mounted. NEC and UL approved non-fused
switch shall provide unit power shutoff. Switch
shall be accessible from outside the unit and
shall provide power off lockout capability.
15. Convenience Outlet:
Outlet shall be factory-installed and internally
mounted with easily accessible 115-v female
receptacle. Shall include 15 amp GFI receptacle
with independent fuse protection. Voltage
required to operate convenience outlet shall be
provided by a factory-installed step-down transformer. Shall be accessible from outside the
unit.
16. High-Static Indoor Fan Motor(s) and Drive(s)
(004-012):
High-static motor(s) and drive(s) shall be factoryinstalled to provide additional performance
range.
17. Condenser Coil Grille:
The grille protects the condenser coil from
damage by large objects without increasing unit
clearances.
18. Compressor Cycle Delay:
Unit shall be prevented from restarting for minimum of 5 minutes after shutdown.
19. Thru-the-Bottom Utility Connectors:
Kit shall provide connectors to permit electrical
connections to be brought to the unit through
the basepan.
20. Fan/Filter Status Switch:
Switch shall provide status of indoor (evaporator) fan (ON/ OFF) or filter (CLEAN/DIRTY).
Status shall be displayed over communication
bus when used with direct digital controls or
with an indicator light at the thermostat.
21. Energy$Recycler Unit:
The package shall be an outdoor rooftop,
surface mounted, electronically controlled, airto-air heat pump unit utilizing a hermetic compressor for cooling and heating duty.
The Energy$Recycler unit shall recover energy
from building exhaust air and precondition
ventilation air to allow higher ventilation
requirements and minimizing energy cost.

Guide specifications 50HJ004-014 (cont)

50HJ

270

31. Humidi-MiZer Adaptive Dehumidification


System:
a. The Humidi-MiZer dehumidification system
shall be factory-installed in the Weathermaster 50HJ004-014 rooftop units, and shall
provide greater dehumidification of the
occupied space by two modes of dehumidification operations beside its normal design
cooling mode:
1) Subcooling mode further subcools the
hot liquid refrigerant leaving the condenser coil when both temperature and
humidity in the space are not satisfied.
2) Hot gas reheat mode shall mix a portion
of the hot gas from the discharge of the
compressor with the hot liquid refrigerant leaving the condenser coil to create
a two-phase heat transfer in the system,
resulting in a neutral leaving-air temperature when only humidity in the space is
not satisfied.
b. The system shall consist of a subcooling/
reheat dehumidification coil located downstream of the standard evaporator coil. This
dehumidification coil is a two-row coil with
the exception of the 004 unit, which has a
one-row coil.
c. The system shall include crankcase heater(s)
for the scroll compressor(s).
d. The system shall include a low outdoor air
temperature switch to lock out both subcooling and hot gas reheat mode when the outdoor-air temperature is below 40 F.
e. The system shall include a Motormaster
low ambient control to ensure the normal
design cooling mode capable of down to
0 F low ambient operation.
f. The system shall include a low-pressure
switch on the suction line to ensure low
pressure start-up of hot gas reheat mode at
lower outdoor temperature condition.
g. The system operation may be controlled by
a field-installed, wall-mounted humidistat.
The dehumidification circuit will then operate only when needed. Field connections for
the humidistat are made in the low-voltage
compartment of the unit control box. The
sensor can be set for any level between 55%
and 80% relative humidity.
h. The system shall include a Thermal Expansion Valve (TXV) to ensure a positive superheat condition and a balance of pressure
drop.

25. Outdoor Air Enthalpy Sensor (EconoMi$er IV


or EconoMi$er2):
The outdoor air enthalpy sensor shall be used
with the EconoMi$er IV or EconoMi$er2
device to provide single enthalpy control. When
used in conjunction with a return air enthalpy
sensor, the EconoMi$er IV or EconoMi$er2
device will provide differential enthalpy control.
The sensor allows the controller to determine if
outside air is suitable for free cooling.
26. Return Air Enthalpy Sensor (EconoMi$er IV or
EconoMi$er2):
The return air enthalpy sensor shall be used
with the EconoMi$er IV or EconoMi$er2
device. When used in conjunction with an outdoor air enthalpy sensor, the EconoMi$er IV or
EconoMi$er2 device will provide differential
enthalpy control.
27. Return Air Temperature Sensor (EconoMi$er
IV or EconoMi$er2):
The return air temperature sensor shall be used
with the EconoMi$er IV or EconoMi$er2
device. When used in conjunction with the standard outdoor air temperature sensor, the controller will provide differential temperature
control.
28. Outdoor Air/Return Air Temperature Sensor
(adjustable) (EconoMi$er2):
Optional sensor uses the PremierLink control
to control outdoor air damper and compressor
operation.
29. Indoor
Air
Quality
(CO2)
Sensor
(EconoMi$er2):
a. Shall have the ability to provide demand ventilation indoor air quality (IAQ) control
through the EconoMi$er2 with an IAQ
sensor.
b. The IAQ sensor shall be available in duct
mount, wall mount, and wall mount with
LED display. The set point shall have adjustment capability.
c. Requires EconoMi$er2 or PremierLink control options.
30. Ultraviolet Germicidal Lamps:
Ultraviolet germicidal lamps are designed to
eliminate odor causing mold and fungus that
may develop in the wet area of the evaporator
section of the unit. The high output, low temperature germicidal lamps are field installed in
the evaporator section of the unit, aimed at the
evaporator coil and condensate pan. The short
wavelength ultraviolet light inhibits and kills
mold, fungus and microbial growth. The lamps
have an output rating at 45 F in 400 fpm airflow of 120 microwatts/cm2 at 1 meter.

905

i. For units with two compressors (sizes 008014), depending on the conditions required
to maintain the space set points, one or both
compressors can operate in subcooling
mode, one compressor could operate in subcooling mode while the other operates in
hot gas reheat mode, or one or both compressors can operate in hot gas reheat
mode.
32. Humidistat:
Field-installed, wall-mounted humidistat is used
to control activation of the dehumidification

package. The humidistat can be set for humidity


levels between 20% and 80% relative humidity.
33. Hinged Panel Option:
Hinged panel option provide hinged access
panels for the filter, compressor, evaporator
fan, and control box areas. Filter hinged panels
permit tool-less entry for changing filters. Each
hinged panel is permanently attached to the
rooftop unit.

50HJ
271

Guide specifications 50HJ004-014


COBRA units
Packaged Rooftop Electric Cooling Unit with
Energy Recovery Capability Constant
Volume Application
HVAC Guide Specifications
Size Range: 3 to 121/2 Tons, Nominal (Cooling)
4.4 to 51 kW, Nominal
(Accessory Electric Heating)
600 to 3000 cfm of outdoor air

Carrier Model
Numbers:

50HJ

50HJ

Part 1 General
1.01 SYSTEM DESCRIPTION
Outdoor rooftop mounted, electrically controlled
heating and cooling unit utilizing a hermetic compressor(s) for cooling duty and accessory electric
heat for heating duty. Energy recovery section is
electrically controlled using a rotary compressor for
cooling and heating duty. Unit shall discharge supply
air vertically.
1.02 QUALITY ASSURANCE
A. Unit well exceeds ASHRAE 90.1-2001 Energy
Standards. Units are Energy Star qualified.
B. Unit shall be rated in accordance with ARI
Standards 210 or 360. Designed in accordance with
UL Standard 1812/1995.
C. Unit shall be designed to conform to ASHRAE 15,
latest revision.
D. Unit shall be UL-tested and certified in accordance
with ANSI Z21.47 Standards and UL-listed and certified under Canadian standards as a total package
for safety requirements.
E. Roof curb shall be designed to conform to NRCA
Standards.
F. Insulation and adhesive shall meet NFPA 90A
requirements for flame spread and smoke
generation.
G. Unit casing shall be capable of withstanding
500-hour salt spray exposure per ASTM B117
(scribed specimen).
H. Unit casing shall be capable of withstanding Federal
Test Method Standard No. 141 (Method 6061)
5000-hour salt spray.
I. Unit shall be designed in accordance with ISO
9001:2000, and shall be manufactured in a facility
registered to ISO 9001:2000.
J. Each unit shall be subjected to a completely automated run testing on the assembly line. Units contain a factory-supplied printout indicating tested
pressures, amperages, data, and inspectors; providing certification of the unit status at the time of
manufacture.

272

1.03 DELIVERY, STORAGE, AND HANDLING


Unit shall be stored and handled per manufacturers
recommendations.
Part 2 Products
2.01 EQUIPMENT (STANDARD)
A. General:
Factory assembled, single-piece heating and cooling
rooftop unit with energy recovery capability for vertical discharge applications. Contained within the
unit enclosure shall be all factory wiring, piping,
controls, refrigerant charge (R-22), and special features required prior to field start-up.
B. Unit Cabinet:
1. General:
a. Unit cabinet shall be constructed of galvanized steel, and shall be bonderized and
coated with a prepainted baked enamel finish on all externally exposed surfaces.
b. Cabinet panels shall be easily removable for
servicing.
c. Holes shall be provided in the base rails for
rigging shackles to facilitate maneuvering
and overhead rigging.
d. Unit shall have 2 factory-installed, sloped
condensate drain pans made of a non-corrosive material, providing a common connection with a minimum 3/4-in. drain, and shall
comply with ASHRAE Standard 62. Condensate drain must be installed per manufacturers recommendations.
e. Unit shall have one factory-installed filter
access panel to provide filter access with
tool-less removal.
2. Rooftop Section:
a. Evaporator fan compartment interior cabinet surfaces shall be insulated with a minimum 1/2-in. thick, 1 lb density, flexible
fiberglass insulation, neoprene coated on the
air side. Aluminum foil-faced fiberglass
insulation shall be used in the gas heat
compartment.
b. Unit shall have standard thru-the-bottom
power connection capability (accessory kit is
required).
3. Energy Recovery Section:
a. All internal panels shall be primer coated.
b. Cabinet interior shall be insulated with a
minimum 1/2-in. thick, rigid foam board
insulation with foil facing on the air side.
C. Fans:
1. Evaporator Fan (Rooftop Section):
a. Fan shall be direct or belt driven as shown
on the equipment drawings. Belt drive shall
include an adjustable-pitch motor pulley.

3. Optional Coils:
a. Copper-fin coils shall be constructed of copper fins mechanically bonded to copper
tubes and copper tube sheets. Galvanized
steel tube sheets shall not be acceptable. A
polymer strip shall prevent coil assembly
from contacting the sheet metal coil pan to
minimize potential for galvanic corrosion
between coil and pan. All copper construction shall provide protection in moderate
coastal environments.
b. E-Coated aluminum-fin coils shall have a
flexible epoxy polymer coating uniformly
applied to all coil surface areas without
material bridging between fins. Coating process shall ensure complete coil encapsulation. Color shall be high gloss black with
gloss 60 deg of 65 to 90% per ASTM
D523-89. Uniform dry film thickness from
0.8 to 1.2 mil on all surface areas including
fin edges. Superior hardness characteristics
of 2H per ASTM D3363-92A and crosshatch adhesion of 4B-5B per ASTM
D3359-93. Impact resistance shall be up to
160 in.-lb (ASTM D2794-93). Humidity and
water immersion resistance shall be up to
minimum 1000 and 250 hours respectively
(ASTM D2247-92 and ASTM D870-92).
Corrosion durability shall be confirmed
through testing to be no less than 1000
hours salt spray per ASTM B117-90. Coil
construction shall be aluminum fins mechanically bonded to copper tubes.
F. Refrigerant Components:
1. Rooftop section refrigerant circuit components
shall include:
a. Fixed orifice metering system (AcutrolTM
device).
b. Refrigerant filter drier.
c. Service gage connections on suction, discharge, and liquid lines.
2. Energy recovery section refrigerant circuit components shall include:
a. Fixed orifice metering device combined with
maximum overcurrent protection (MOCP)
type thermostatic expansion valve (TXV) to
prevent compressor overloading.
b. Service gage connections on suction and discharge lines to charge and evacuate the
system.
c. Ability to route gage hoses through the
energy recovery section side panel to eliminate air bypass during diagnostic periods.
d. Reversing valve.
e. Accumulator located in compressor suction
line.

273

50HJ

b. Fan wheel shall be double-inlet type with


forward-curved blades.
c. Bearings shall be sealed, permanently lubricated ball-bearing type for longer life and
lower maintenance.
d. Evaporator fan shall be made from steel with
a corrosion-resistant finish and shall be
dynamically balanced.
2. Condenser Fan (Rooftop Section):
a. Fan shall be of the direct-driven (with totally
enclosed motors) propeller type and shall
discharge air vertically.
b. Fan shall have aluminum blades riveted to
corrosion-resistant steel spiders and shall be
dynamically balanced.
3. Supply Fan and Exhaust Air Fan (Energy
Recovery Section):
a. Fans shall be of the double-inlet forwardcurved centrifugal type.
b. Fan wheels shall be made from steel with a
corrosion-resistant finish and shall be statically and dynamically balanced.
c. Bearings shall be sealed and permanently
lubricated for longer life and lower
maintenance.
D. Compressor(s):
1. Rooftop Section:
a. Fully hermetic type, internally protected
scroll-type.
b. Factory mounted on rubber grommets and
internally spring mounted for vibration
isolation.
c. On independent circuits (008-014).
2. Energy Recovery Section:
a. Fully hermetic type with electrical overload
protection.
b. Factory rubber shock mounted vibration
isolation.
E. Coils:
1. Rooftop Section:
a. Standard evaporator and condenser coils
shall have aluminum lanced plate fins
mechanically bonded to seamless internally
grooved copper tubes with all joints brazed.
b. Dual compressor models (size 008-014)
shall have face-split type evaporator coil (circuit no. 1 on bottom).
2. Energy Recovery Section:
a. Supply and exhaust air coils shall have aluminum plate fins mechanically bonded to
internally enhanced seamless copper tubes
with all joints brazed.
b. Tube sheet openings shall be belled to prevent tube wear.

50HJ

Guide specifications 50HJ004-014


COBRA units (cont)
G. Filter Section:
1. Rooftop Section:
a. Standard filter section shall consist of
factory-installed, low velocity, throwaway
2-in. thick fiberglass filters of commercially
available sizes.
b. Filter face velocity shall not exceed 320 fpm
at nominal airflows.
c. Filter section should use only one size filter.
d. Filters shall be accessible through an access
panel with no-tool removal.
2. Energy Recovery Section:
a. Standard filter section shall consist of
factory-installed low-velocity, throwaway
fiberglass filters of commercially available
sizes.
b. Filter face velocity shall not exceed 300 fpm
at nominal airflows.
H. Controls and Safeties:
1. Unit Controls:
Unit shall be complete with self-contained lowvoltage control circuit protected by a fuse on
the 24-v transformer side (size 008-014 units
have a resettable circuit breaker).
2. Safeties:
a. Rooftop Section:
1) Unit shall incorporate a solid-state compressor protector which provides anticycle reset capability at the space thermostat, should any of the following standard safety devices trip and shut off
compressor.
2) Compressor overtemperature,
overcurrent.
3) Loss-of-charge/low-pressure switch.
4) Freeze-protection thermostat, evaporator coil.
5) High-pressure switch.
6) Automatic reset motor thermal overload
protector.
7) The lockout protection shall be easily
disconnected at the control board, if
necessary.
b. Energy recovery section shall be provided
with the following minimum protections:
1) High-pressure switch.
2) Unit shall incorporate an outdoor coil
defrost system to prevent excessive frost
accumulation during heating duty.
Defrost system shall be initiated on the
basis of time and coil temperature. A
30/50/90 minute timer shall activate
defrost cycle only if coil temperature is
low enough to indicate a heavy frost
condition. Defrost cycle shall terminate
when the defrost thermostat is satisfied

274

and shall have a positive termination


time of 10 minutes. A 5-minute time
delay shall be built into the defrost control to prevent compressor short cycling.
I. Operating Characteristics:
1. Rooftop Section:
a. Unit shall be capable of starting and running
at 125 F ambient outdoor temperature,
meeting maximum load criteria of ARI Standard 210/240 or 360 at 10% voltage.
b. Compressor with standard controls shall be
capable of operation down to 25 F ambient
outdoor temperature.
2. Energy Recovery Section:
a. Unit shall be capable of starting and running
at 125 F ambient outdoor temperature,
meeting maximum load criteria of ARI Standard 210/240 10% voltage.
b. Compressor with standard controls shall be
capable of operation down to 55 F ambient
outdoor temperature in cooling mode and
20 F ambient outdoor temperature in heating mode.
J. Electrical Requirements:
All unit power wiring shall enter unit cabinet at a
single factory-predrilled location.
K. Motors:
1. Rooftop Section:
a. Compressor motors shall be cooled by
refrigerant gas passing through motor windings and shall have line break thermal and
current overload protection.
b. Evaporator-fan motor shall have permanently lubricated bearings and inherent
automatic-reset thermal overload protection.
Evaporator motors are designed specifically
for Carrier and do not have conventional
horsepower (hp) ratings listed on the motor
nameplate. Motors are designed and qualified in the air-over location downstream of
the cooling coil and carry a maximum continuous bhp rating that is the maximum
application bhp rating for the motor; no
safety factors above that rating may be
applied.
c. Totally enclosed condenser-fan motor shall
have permanently lubricated bearings, and
inherent automatic-reset thermal overload
protection.
2. Energy Recovery Section:
a. Compressor motors shall be cooled by
refrigerant gas passing through motor windings and shall include thermal overload
protection.

d. Keypad lock feature to prevent unauthorized


changing of program control.
e. Holiday Mode With a single touch of a
button mode adjusts all comfort levels for
optimum efficiency while the home is
unoccupied and restores the settings to normal upon return.
f. Comfort and energy savings Seven-day
programming with 4 temperature changes
and humidity set point changes provided per
day, means proper ventilation during
occupied periods and savings through
reduced energy usage when the building is
unoccupied.
g. Easy to use Simple instructions are
located inside the thermostats door.
h. Duplicate Programming Copy the programmed schedule of one day to the next
using the copy function.
i. Override Capability Hold function allows
the regular schedule to be bypassed with a
temporary setting.
j. Battery-Free Non-volatile RAM chip
requires no battery backup. Retained in
memory so reprogramming is not required
after power loss.
3. Humidistat:
Field-installed, wall-mounted humidistat is used
to control activation of the dehumidification
package. The humidistat can be set for humidity
levels between 20% and 80% relative humidity.
4. Roof Curbs (Vertical):
a. Full perimeter roof curb with exhaust capability providing separate airstreams for
energy recovery from the exhaust air without supply air contamination.
b. Formed galvanized steel with wood nailer
strip and shall be capable of supporting
entire unit weight.
c. Permits installation and securing of ductwork
to curb prior to mounting unit on the curb.
d. Sleeper rail shall be available for use with
standard unit roof curb.
5. Electric Resistance Heaters and Single Point
Kits:
a. Open wire nichrome elements with all necessary safety operating controls.
b. UL listed and indicated on basic unit informative plate.
c. Available in multiples to match heating
requirements.
d. Single point kits available for each heater
when required.

275

50HJ

b. Supply and exhaust-air fan motor shall have


permanently lubricated bearings and
inherent automatic reset thermal overload
protection.
L. Energy Recovery Section Supply and Exhaust Air
Damper:
1. Modulating type supply air damper opens to
preset position any time system fans are energized to provide specified ventilation airflow.
2. Motorized spring return supply air damper
automatically closes on loss of power.
3. Capable of providing up to 100% outside air
when matched to proper size rooftop unit.
4. Functions as economizer when outdoor air
enthalpy sufficient to provide free cooling.
5. Barometric type exhaust air damper with
adjustable stops to limit exhaust airflow to specified cfm. Gravity type damper closes automatically on loss of power or fan shut down.
6. Supply and exhaust rain hoods with cleanable
aluminum mesh filters on supply air inlet and
bird screens on exhaust air outlet standard.
M. Special Features:
Certain features are not applicable when the features designated * are specified. For assistance in
amending the specifications, contact your local
Carrier Sales Office.
*
1. Carrier PremierLink Controls:
a. Shall be available as a factory-installed or as
a field-installed accessory.
b. Shall work with CCN and ComfortVIEW
software.
c. Shall be compatible with ComfortLink
controllers.
d. Shall be ASHRAE 62-2001 compliant.
e. Shall accept a CO2 sensor in the conditioned
space Demand Control Ventilation (DCV)
Ready.
f. Shall have baud communication rate of
38.4K or faster.
g. Shall be Internet Ready.
h. Shall include an integrated economizer
controller.
2. Electronic Programmable Light Commercial
Thermidistat Accessory:
The Light Commercial Thermidistat Accessory
is a fully programmable thermostat with a builtin humidistat.
a. Provides direct control of energy recovery
unit control and rooftop unit fans in
response to occupied/unoccupied output
signals.
b. Liquid crystal display (LCD) equipment function indicators display operating mode.
c. Five-minute compressor delay with override
functions.

Guide specifications 50HJ004-014


COBRA units (cont)
*

50HJ

276

6. Head Pressure Control Package:


Consists of solid-state control and condensercoil temperature sensor to maintain condensing
temperature between 90 F and 110 F at outdoor ambient temperatures down to 20 F by
condenser-fan speed modulation or condenserfan cycling and wind baffles.
7. Condenser Coil Hail Guard Assembly:
Hail guard shall protect against damage from
hail and flying debris.
8. Unit-Mounted, Non-Fused Disconnect Switch:
Shall be factory-installed, internally mounted.
NEC and UL approved non-fused switch shall
provide unit power shutoff. Shall be accessible
from outside the unit and shall provide power
off lockout capability. (80 amp MAXIMUM)
9. Convenience Outlet:
Shall be factory-installed and internally
mounted with easily accessible 115-v female
receptacle. Shall include 15 amp GFI receptacle
with independent fuse protection. Voltage
required to operate convenience outlet shall be
provided by a factory-installed step-down transformer. Shall be accessible from outside the
unit.
10. High-Static Indoor Fan Motor(s) and Drive(s)
(004-012):
High-static motor(s) and drive(s) shall be
factory-installed to provide additional performance range.
11. Condenser Coil Grille:
The grille protects the condenser coil from
damage by large objects without increasing unit
clearances.
12. Compressor Cycle Delay:
Unit shall be prevented from restarting for minimum of 5 minutes after shutdown.
13. Thru-the-Bottom Utility Connectors:
Kit shall provide connectors to permit gas and
electrical connections to be brought to the unit
through the basepan.
14. Fan/Filter Status Switch:
Provides status of indoor (evaporator) fan (ON/
OFF) or filter (CLEAN/DIRTY). Status shall be
displayed over communication bus when used
with direct digital controls or with an indicator
light at the thermostat.
15. Outdoor Air Enthalpy Sensor:
The outdoor air enthalpy sensor shall be used
to provide single enthalpy control. When used
in conjunction with a return air enthalpy sensor,
the unit will provide differential enthalpy
control. The sensor allows the unit to determine
if outside air is suitable for free cooling.

16. Return Air Enthalpy Sensor:


The return air enthalpy sensor shall be used in
conjunction with an outdoor air enthalpy sensor
to provide differential enthalpy control.
17. Indoor Air Quality (CO2) Sensor:
a. Shall have the ability to provide demand ventilation indoor air quality (IAQ) control.
b. The IAQ sensor shall be available in duct
mount, wall mount, and wall mount with
LED display. The set point shall have adjustment capability.
18. Humidi-MiZer Adaptive Dehumidification
System:
a. The Humidi-MiZer dehumidification system
shall be factory-installed in the Weathermaster 50HJ004-014 rooftop units, and shall
provide greater dehumidification of the
occupied space by two modes of dehumidification operations beside its normal design
cooling mode:
1) Subcooling mode further subcools the
hot liquid refrigerant leaving the condenser coil when both temperature and
humidity in the space are not satisfied.
2) Hot gas reheat mode shall mix a portion
of the hot gas from the discharge of the
compressor with the hot liquid refrigerant leaving the condenser coil to create
a two-phase heat transfer in the system,
resulting in a neutral leaving-air temperature when only humidity in the space is
not satisfied.
b. The system shall consist of a subcooling/
reheat dehumidification coil located downstream of the standard evaporator coil. This
dehumidification coil is a two-row coil with
the exception of the 004 unit, which has a
one-row coil.
c. The system shall include crankcase heater(s)
for the scroll compressor(s).
d. The system shall include a low outdoor air
temperature switch to lock out both subcooling and hot gas reheat mode when the outdoor-air temperature is below 40 F.
e. The system shall include a Motormaster
low ambient control to ensure the normal
design cooling mode capable of down to
0 F low ambient operation.
f. The system shall include a low-pressure
switch on the suction line to ensure low
pressure start-up of hot gas reheat mode at
lower outdoor temperature condition.

g. The system operation may be controlled by


a field-installed, wall-mounted humidistat.
The dehumidification circuit will then operate only when needed. Field connections for
the humidistat are made in the low-voltage
compartment of the unit control box. The
sensor can be set for any level between 55%
and 80% relative humidity.
h. The system shall include a Thermal Expansion Valve (TXV) to ensure a positive superheat condition and a balance of pressure
drop.
i. For units with two compressors (sizes 008014), depending on the conditions required
to maintain the space set points, one or both

compressors can operate in subcooling


mode, one compressor could operate in subcooling mode while the other operates in
hot gas reheat mode, or one or both compressors can operate in hot gas reheat
mode.
19. Hinged Panel Option:
Hinged panel option provides hinged access
panels for the filter, compressor, evaporator
fan, and control box areas. Filter hinged panels
permit tool-less entry for changing filters. Each
hinged panel is permanently attached to the
rooftop unit.

50HJ
277

Guide specifications 50HJ015,017


Packaged Rooftop Electric Cooling Unit with
Electric or Glycol Heat Constant Volume
Application
HVAC Guide Specifications
Size Range: 12 to 15 Tons Nominal (Cooling)
14 to 80 kW Nominal (Electric Heating)
123,000 to 405,000 Btuh
Nominal (Glycol Heating Coil)

50HJ

Carrier Model
Number:
50HJ

Part 1 General
1.01 SYSTEM DESCRIPTION
Unit is an outdoor rooftop mounted, electrically controlled heating and cooling unit utilizing scroll hermetic compressors for cooling duty and electric or
glycol coils for heating duty. Supply air shall be discharged downward or horizontally (with horizontal
supply/return curb adapter assembly), as shown on
contract drawings. Standard unit shall include a
manual outdoor-air inlet.
1.02 QUALITY ASSURANCE
A. Unit shall well exceed the energy efficiency requirements of ASHRAE Standard 90.1 - 2001. Units are
Energy Star qualified.
B. Unit shall be rated in accordance with ARI
Standards 270 and 360 and all units shall be
designed in accordance with UL Standard 1995.
C. Unit shall be designed to conform to ASHRAE 15.
D. Unit shall be ETL and ETL, Canada tested and certified in accordance with ANSI Z21.47 Standards as a
total package.
E. Roof curb shall be designed to conform to NRCA
Standards.
F. Insulation and adhesive shall meet NFPA 90A
requirements for flame spread and smoke
generation.
G. Unit casing shall be capable of withstanding
500-hour salt spray exposure per ASTM B117
(scribed specimen).
H. Unit shall be manufactured in a facility registered to
ISO 9001:2000.
1.03 DELIVERY, STORAGE, AND HANDLING
Unit shall be stored and handled per manufacturers
recommendations.
Part 2 Products
2.01 EQUIPMENT (STANDARD)
A. General:
Each unit shall be a factory assembled, single-piece
heating and cooling unit. Contained within the unit
enclosure shall be all factory wiring, piping, controls,
278

refrigerant charge (R-22), and special features


required prior to field start-up.
B. Unit Cabinet:
1. Constructed of galvanized steel (G90 1.8 oz.
of zinc per square foot of sheet metal), bonderized and primer-coated on both sides and
coated with a baked polyester thermosetting
powdercoating finish on the outer surface.
2. Indoor blower compartment interior surfaces
shall be insulated with a minimum 1/2-in. thick,
1 lb density fiberglass insulation. Fiberglass
insulation shall be bonded with a thermosetting
resin (8 to 12% by weight nominal, phenol
formaldehyde typical), and coated with an
acrylic or other material that meets the NFPA
90 flame retardance requirements and has an
R Value of 3.70.
3. Cabinet panels shall be easily removable for servicing. Cabinet panels are minimum 20 gage.
Panels shall have 1/2-in. thick, 1.5-lb density
insulation.
4. Filters shall be accessible through an access
panel.
5. Holes shall be provided in the base rails (minimum 12 gage) for rigging shackles to facilitate
overhead rigging.
6. Unit shall contain a sloped drain pan, to prevent standing water from accumulating. Pan
shall be fabricated of hot dipped zinc coated
minimum spangle steel. Zinc coating shall be
G90 designation according to ASTM Standard
A653. Unit shall contain a factory-installed
nonferrous main condensate drain connection.
C. Fans:
1. Indoor blower (evaporator fan):
a. Fan shall be belt driven. Belt drive shall
include an adjustable pulley. The standard
fan drive shall have a factory-installed lowmedium static pressure fan drive. The alternate fan drive option shall have a factoryinstalled high static pressure fan drive.
b. Fan wheel shall be made from steel with a
corrosion resistant finish. It shall be a
dynamically balanced, double-inlet type with
forward-curved blades.
2. Condenser fans shall be of the direct-driven
propeller type, with corrosion-resistant blades
riveted to corrosion-resistant steel supports.
They shall be dynamically balanced and discharge air upwards.
D. Compressor(s):
1. Fully hermetic, scroll type, internally protected.
2. Factory spring-shock mounted and internally
spring mounted for vibration isolation.
3. On electrically and mechanically independent
refrigerant circuits.

E.

F.

G.

H.

I.

J. Electrical Requirements:
All unit power wiring shall enter unit cabinet at a
single location.
K. Motors:
1. Compressor motors shall be cooled by refrigerant gas passing through motor windings and
shall have line break thermal and current overload protection.
2. All fan motors shall have permanently lubricated, sealed bearings and inherent automaticreset thermal overload protection or manual
reset calibrated circuit breakers. Evaporator
motors are designed specifically for Carrier and
do NOT have conventional horsepower (hp)
ratings listed on the motor nameplate. Motors
are designed and qualified in the air-over location downstream of the cooling coil and carry a
maximum continuous bhp rating that is the
maximum application bhp rating for the motor;
no safety factors above that rating may be
applied.
3. All indoor-fan motors 5 hp and larger shall
meet the minimum efficiency requirements as
established by the Energy Policy Act of 1992
(EPACT) effective October 24, 1997.
L. Special Features:
Certain features are not applicable when the
features designated * are specified. For assistance in
amending the specifications, contact your local
Carrier Sales Office.
* 1. Carrier PremierLink Controls:
a. Shall be available as a factory-installed or as
a field-installed accessory.
b. Shall work with CCN and ComfortVIEW
software.
c. Shall be compatible with ComfortLink
controllers.
d. Shall be ASHRAE 62-2001 compliant.
e. Shall accept a CO2 sensor in the conditioned
space Demand Control Ventilation (DCV)
Ready.
f. Shall have baud communication rate of
38.4K or faster.
g. Shall be Internet Ready.
h. Shall include an integrated economizer
controller.
2. Optional Coils:
a. Optional pre-coated aluminum-fin coils shall
have a durable epoxy-phenolic coating to
provide protection in mildly corrosive coastal
environments. Coating shall be applied to
the aluminum fin stock prior to the fin
stamping process to create an inert barrier
between the aluminum fin and copper tube.
Epoxy-phenolic barrier shall minimize galvanic action between dissimilar metals.

279

50HJ

4. All compressors shall have 70 W crankcase


heaters.
Coils:
1. Standard evaporator and condenser coils shall
have aluminum plate fins mechanically bonded
to seamless internally grooved copper tubes
with all joints brazed.
2. Coils shall be leak tested at 150 psig and pressure tested at 450 psig.
Refrigerant Components:
Refrigerant circuit components shall include:
1. Thermostatic expansion valve (TXV).
2. Filter driers.
3. Gage port and connections on suction, discharge, and liquid lines.
Filter Section:
Standard filter section shall consist of 2 sizes of
factory-installed 2-in. thick throwaway fiberglass filters of commercially available sizes. Filters shall be
approximately 10% efficient with an airside pressure
drop of approximately 0.07 in. wg (clean).
Controls and Safeties:
1. Unit Controls:
a. Economizer control (optional)
b. Capacity control (2-step)
c. Unit shall be complete with self-contained
low-voltage control circuit.
2. Safeties:
a. Unit shall incorporate a solid-state compressor lockout which provides reset capability at
the space thermostat, should any of the
following safety devices trip and shut off
compressor:
1) Compressor lockout protection provided
for either internal or external overload.
2) Low-pressure switch.
3) Dual freezestats (evaporator coil).
4) High-pressure switch.
b. Supply-air thermostat shall be located in the
unit.
c. Heating section shall be provided with a
high-temperature limit switch.
Operating Characteristics:
1. Unit shall be capable of starting and running at
120 F (size 017) or 125 F (size 015) ambient
outdoor temperature per maximum load criteria
of ARI Standard 360.
2. Unit with standard controls will operate in cooling down to an outdoor ambient temperature of
40 F.
3. Unit shall be provided with fan time delay to
prevent cold air delivery.

Guide specifications 50HJ015,017 (cont)

50HJ

b. Optional copper-fin coils shall be constructed of copper fins mechanically bonded


to copper tubes and copper tube sheets.
Galvanized steel tube sheets shall not be
acceptable. A polymer strip shall prevent
coil assembly from contacting the sheet
metal coil pan to minimize potential for galvanic corrosion between coil and pan. All
copper construction shall provide protection
in moderate coastal environments.
c. Optional E-Coated aluminum-fin coils shall
have a flexible epoxy polymer coating uniformly applied to all coil surface areas without material bridging between fins. Coating
process shall ensure complete coil encapsulation. Color shall be high gloss black with
gloss 60 deg of 65 to 90% per
ASTM D523-89. Uniform dry film thickness
from 0.8 to 1.2 mil on all surface areas
including fin edges. Superior hardness characteristics of 2H per ASTM D3363-92A
and cross-hatch adhesion of 4B-5B per
ASTM D3359-93. Impact resistance shall be
up to 160 in./lb (ASTM D2794-93). Humidity and water immersion resistance shall be
up to minimum 1000 and 250 hours respectively (ASTM D2247-92 and ASTM D87092). Corrosion durability shall be confirmed
through testing to be no less than
1000 hours salt spray per ASTM B117-90.
Coil construction shall be aluminum fins
mechanically bonded to copper tubes.
d. Optional E-Coated copper-fin coils shall have
a flexible epoxy polymer coating uniformly
applied to all coil surface areas without material bridging between fins. Coating process
shall ensure complete coil encapsulation.
Color shall be high gloss black with gloss
60 deg of 65 to 90% per ASTM D523-89.
Uniform dry film thickness from 0.8 to
1.2 mil on all surface areas including fin
edges. Superior hardness characteristics of
2H per ASTM D3363-92A and cross-hatch
adhesion of 4B-5B per ASTM D3359-93.
Impact resistance shall be up to 160 in./lb
(ASTM D2794-93). Humidity and water
immersion resistance shall be up to minimum 1000 and 250 hours respectively
(ASTM D2247-92 and ASTM D870-92).
Corrosion durability shall be confirmed
through testing to be no less than
1000 hours salt spray per ASTM B117-90.
Coil construction shall be copper fins
mechanically bonded to copper tubes with
copper tube sheets. Galvanized steel tube
sheets shall not be acceptable. A polymer
strip shall prevent coil assembly from contacting sheet metal coil pan to maintain coating integrity and minimize corrosion
potential between coil and pan.

280

905

3. Roof Curbs (Horizontal and Vertical):


a. Formed of 16-gage galvanized steel with
wood nailer strip and shall be capable of
supporting entire unit weight.
b. Permits installing and securing ductwork to
curb prior to mounting unit on the curb.
4. Horizontal Adapter Roof Curb:
Includes factory-assembled adapter and internal
duct.
NOTE: Power exhaust or barometric relief must
be mounted in the return ductwork when used
in conjunction with this accessory.
5. Integrated Economizers:
a. Integrated integral modulating type capable
of simultaneous economizer and compressor
operation.
b. Available as a factory-installed option in vertical supply/return configuration only. (Available as a field-installed accessory for
dedicated horizontal and/or vertical supply
return configurations.)
c. Includes all hardware and controls to provide
cooling with outdoor air.
d. Equipped with low-leakage dampers, not to
exceed 2% leakage at 1 in. wg pressure
differential.
e. Capable of introducing up to 100% outdoor
air.
f. EconoMi$er IV and EconoMi$er2 shall be
equipped with a barometric relief damper.
g. Designed to close damper(s) during loss-ofpower situations with spring return built into
motor.
h. Dry bulb outdoor-air temperature sensor
shall be provided as standard. Outdoor air
sensor set point is adjustable and shall range
from 40 to 100 F. For the EconoMi$er IV,
the return air sensor, indoor enthalpy sensor,
and outdoor enthalpy sensor shall be
provided as field-installed accessories to
provide enthalpy control, differential
enthalpy control, and differential dry bulb
temperature control. For the EconoMi$er2,
the enthalpy, differential temperature
(adjustable), and differential enthalpy control shall be provided as field-installed
accessories.
i. The EconoMi$er IV and EconoMi$er2 shall
have a gear-driven parallel blade design.
j. EconoMi$er IV microprocessor control shall
provide control of internal building pressure
through its accessory power exhaust function. Factory set at 100%, with a range of
0% to 100%.
k. EconoMi$er2 shall be capable of control
from a 4 to 20 mA signal through optional
4 to 20 mA design without microprocessor

905

* 9. Barometric Relief Damper Package:


a. Package shall include damper, seals, hardware, and hoods to relieve excess internal
pressure.
b. Damper shall close due to gravity upon unit
shutdown.
c. Damper package must be field-installed in
return-air ductwork when used with optional
side return connections.
*10. Power Exhaust:
Package shall include an exhaust (propeller
style) fan, 1/2 Hp 208-230, 460 v (factorywired for 460 v) direct drive motor, and damper
for vertical flow units with economizer to control over-pressurization of building. Power
Exhaust package must be field-installed in
return-air ductwork when used with optional
side return connections.
*11. Head Pressure Control Package:
Package shall consist of an accessory outdoorair package and a solid-state control with condenser coil temperature sensor for controlling
condenser-fan motor speed to maintain condensing temperature between 90 F and 100 F
at outdoor ambient temperature down to 20 F.
12. Low-Ambient Kits:
When used, kit allows units to operate at lower
outdoor ambient temperatures down to 20 F.
*13. Electronic Programmable Thermostat:
Unit shall be capable of using deluxe fullfeatured electronic thermostat.
14. MoistureMi$er Dehumidification Package:
The dehumidification package is a factoryinstalled option that provides increased dehumidification by further subcooling the hot liquid
refrigerant leaving the condenser coil. The
package consists of a single row, 3/8 to
12.25 sq ft subcooling coil located on the leaving airside of the evaporator coil. The location
of this coil in the indoor airstream greatly
enhances the latent capacity of the unit.
The package shall be equipped with low pressure switch(es) and TXVs. Low pressure
switch(es) prevents evaporator coil freeze-up
and TXVs assure a positive superheat condition. If the operation of the subcooling coil is
controlled by a field-installed wall-mounted
humidistat, the dehumidification circuit will then
operate only when needed. Optional field
connections for the humidistat are made in the
low voltage compartment of the unit control
box.
15. Winter Start Time-Delay Relay:
Relay shall be used in conjunction with the
accessory low-ambient kit or head pressure
control device, permits operation in cooling at

281

50HJ

control (required for PremierLink or third


party control interface).
l. EconoMi$er IV Microprocessor Occupied
Minimum Damper Position Setting maintains the minimum airflow into the building
during occupied period providing design
ventilation rate for full occupancy (damper
position during heating). A remote potentiometer may be used to override the set
point.
m. EconoMi$er IV Microprocessor Unoccupied
Minimum Damper Position Setting The
EconoMi$er IV dampers shall be completely
closed when the unit is in the occupied
mode.
n. EconoMi$er IV Microprocessor Maximum
Damper Position Setting Setting the maximum position of the damper prevents the
introduction of large amounts of hot or cold
air into the space. This position is intended
to satisfy the base minimum ventilation rate.
o. EconoMi$er IV Microprocessor IAQ control modulates the outdoor-air damper to
provide ventilation based on the optional 2
to 10 vdc CO2 sensor input.
p. Compressor lockout sensor (opens at 35 F,
closes at 50 F).
q. Actuator shall be direct coupled to economizer gear, eliminating linkage arms and
rods.
r. Control LEDs:
1) When the outdoor air damper is capable
of providing free cooling, the Free
Cool LED shall illuminate.
2) The IAQ LED indicates when the module is on the DCV mode.
3) The EXH LED indicates when the
exhaust fan contact is closed.
s. Remote Minimum Position Control A
field-installed accessory remote potentiometer allows the outdoor air damper to be
opened or closed beyond the minimum
position in the occupied mode for modified
ventilation.
6. Two-Position Damper:
Two-position damper package shall include single blade damper and 24-v motor. Admits up to
25% outdoor air, and shall close upon unit
shutoff. Damper shall cover 3.8-in. high by
17.75-in. wide (117.8 sq. in.) opening in return
air upper panel.
7. Accessory Compressor Cycle Delay:
Compressor shall be prevented from restarting
for a minimum of 5 minutes after shutdown.
* 8. Thermostats and Subbases:
Thermostats and subbase shall provide staged
heating and cooling in addition to automatic (or
manual) changeover and fan control.

Guide specifications 50HJ015,017 (cont)

50HJ

lower outdoor ambient temperatures. See price


pages for more information.
16. Service Option Package:
a. Hinged access panels for the filter, compressors, evaporator fan, and control box areas.
Filter hinged access panels permit tool-less
entry for changing filters. Evaporator fan
hinged access panel shall be field-convertible
to a tool-less entry by removing and discarding screws. Each external hinged access
panel shall be permanently attached to the
rooftop unit.
b. Convenience outlet shall be factory-installed
and internally mounted with an externally
accessible 115-v, 15 amp GFI, female
receptacle with hinged cover. Voltage
required to operate convenience outlet shall
be provided by a field-supplied and properly
fused separate branch circuit.
c. Non-fused disconnect switch shall be
factory-installed, internally mounted, NEC
and UL approved. Non-fused switch shall
provide unit power shutoff. The control
access door shall be interlocked with the
non-fused disconnect. The disconnect switch
must be in the OFF position to open the
control box access door. Shall be accessible
from outside the unit and shall provide
power off lockout capability.
17. Electric Heater Package:
a. Fully assembled for installation. The packages are designed in accordance with UL
safety standards 1995 and listed by ETL.
Heater construction approved by UL 5306.
b. Heater element open coil resistance wire,
nickel-chrome alloy, 0.29 inches inside
diameter, strung through ceramic insulators
mounted on metal frame. Coil ends are
staked and welded to terminal screw slots.
c. Heater assemblies are provided with integral
fusing for protection of internal heater circuits not exceeding 48 amps each.
d. Auto reset thermo limit controls, magnetic
heater contactors (24 v coil) and terminal
block all mounted in electric heater control
box (minimum 18 ga. galvanized steel)
attached to end of heater assembly.
e. Certain models (208-230/3/60, 42/56 and
56/75 kW) require an additional heater control box that contains a field power terminal
block, a field power wiring fuse block and
fuses (125 A, 250 V, class K5 or RK%);
included with the electric heater assembly
package.
f. All power wiring leads are 10 AWG and control wiring leads are 18 AWG, both rated at
105 deg. C.

282

905

18. Glycol Coil: (Hot Water Coil)


Coil shall be 2-row copper tube (1/2-in. OD)
with aluminum plate fins (15 fins/in.) and
(1.625 in. OD) copper headers. Input and output connections shall be (1.625 in. ODM) copper stubs for sweat connections. Coil shall be
furnished with suitable support rails, end plates,
and hardware for ready field installation in
heater compartment.
19. Alternate Drive:
Drive shall provide higher static drive capability
to enhance evaporator-fan performance rpm
range.
20. Hail Guard:
Hail guard shall protect the condenser coil from
hail, flying debris, and damage by large objects
without increasing unit clearances.
21. Ultraviolet Germicidal Lamps:
Ultraviolet germicidal lamps are designed to
eliminate odor causing mold and fungus that
may develop in the wet area of the evaporator
section of the unit. The high output, low temperature germicidal lamps are field installed in
the evaporator section of the unit, aimed at the
evaporator coil and condensate pan. The short
wavelength ultraviolet light inhibits and kills
mold, fungus and microbial growth. The lamps
have an output rating at 45 F in 400 fpm airflow of 120 microwatts/cm2 at 1 meter.
22. Stainless Steel Condensate Pan:
Stainless steel condensate pans shall be available for condensate collection.
23. Outdoor Air Enthalpy Sensor (EconoMi$er IV
or EconoMi$er2):
The outdoor air enthalpy sensor shall be used
with the EconoMi$er IV or EconoMi$er2
device to provide single enthalpy control. When
used in conjunction with a return air enthalpy
sensor, the EconoMi$er IV or EconoMi$er2
device will provide differential enthalpy control.
The sensor allows the controller to determine if
outside air is suitable for free cooling.
24. Return Air Enthalpy Sensor (EconoMi$er IV or
EconoMi$er2):
The return air enthalpy sensor shall be used
with the EconoMi$er IV or EconoMi$er2
device. When used in conjunction with an outdoor air enthalpy sensor, the EconoMi$er IV or
EconoMi$er2 device will provide differential
enthalpy control.
25. Return Air Temperature Sensor (EconoMi$er
IV or EconoMi$er2):
The return air temperature sensor shall be used
with the EconoMi$er IV or EconoMi$er2
device. When used in conjunction with the standard outdoor air temperature sensor, the

EconoMi$er IV or EconoMi$er2 device will


provide differential temperature control.
26. Indoor Air Quality (CO2) Room Sensor
(EconoMi$er IV):
Sensor shall have the ability to provide demand
ventilation control through the EconoMi$er IV.
The IAQ sensor shall be wall mounted with an
LED display in parts per million. The set point
shall have adjustment capability.
27. Return Air CO2 Sensor (EconoMi$er IV):
Sensor shall have the ability to provide demand
ventilation control through the EconoMi$er IV.
The IAQ sensor shall be duct mounted. The set
point shall have adjustment capability.
28. Humidistat:
Field-installed, wall-mounted humidistat is used
to control activation of the dehumidification
package. The humidistat can be set for humidity
levels between 20% and 80% relative humidity.

29. Light Commercial Thermidistat Device:


Field-installed wall-mounted thermidistat is used
to control temperature and activation of the
dehumidification package. The Thermidistat
device can be set for humidity settings from
50% to 90% relative humidity.
30. Fan/Filter Status Switch:
Status switch shall provide status of indoor
(evaporator) fan (ON/OFF) or filter (CLEAN/
DIRTY). Status shall be displayed over communication bus when used with direct digital controls or with an indicator light at the thermostat.
31. Manual Outdoor-Air Damper:
Manual damper package shall consist of
damper, birdscreen, and rainhood which can be
preset to admit up to 50% outdoor air for year
round ventilation.

50HJ

905

283

Guide specifications 50HJ020-028


Packaged Rooftop Electric Cooling Unit with
Optional Electric Heat Constant Volume
Application
Size Range: 18 to 25 Tons, Nominal (Cooling)
19 to 78 kW Nominal (Electric Heating)

50HJ

Carrier Model
Number:
50HJ

Part 1 General
1.01 SYSTEM DESCRIPTION
Unit is an outdoor rooftop mounted, electrically controlled heating and cooling unit utilizing scroll hermetic compressors with crankcase heaters for
cooling duty and gas combustion heat for heating
duty. Supply air shall be discharged downward or
horizontally, as shown on contract drawings.
1.02 QUALITY ASSURANCE
A. Unit shall well exceed the energy efficiency requirements of ASHRAE standard 90.1-2001. Unit shall
be Energy Star qualified.
B. Unit shall be rated in accordance with ARI
Standards 270 and 360 and all units shall be
designed in accordance with UL Standard 1995.
C. Unit shall be designed to conform to ASHRAE 15.
D. Unit shall be UL and UL, Canada tested and certified in accordance with ANSI Z21.47 Standards as a
total package.
E. Roof curb shall be designed to conform to NRCA
Standards.
F. Insulation and adhesive shall meet NFPA 90A
requirements for flame spread and smoke generation.
G. Unit casing shall be capable of withstanding
500-hour salt spray exposure per ASTM B117
(scribed specimen).
H. Unit shall be manufactured in a facility registered to
ISO 9001:2000.
1.03 DELIVERY, STORAGE, AND HANDLING
Unit shall be stored and handled per manufacturers
recommendations.
Part 2 Products
2.01 EQUIPMENT (STANDARD)
A. General:
The 50HJ unit shall be a factory assembled, singlepiece heating (if equipped) and cooling unit. Contained within the unit enclosure shall be all factory
wiring, piping, controls, refrigerant charge (R-22),
and special features required prior to field start-up.

284

B. Unit Cabinet:
1. Constructed of galvanized steel (G90 1.8 oz.
of zinc per square foot of sheet metal), bonderized and primer-coated on both sides and
coated with a baked polyester thermosetting
powdercoating finish on the outer surface.
2. Indoor blower compartment interior surfaces
shall be insulated with a minimum 1/2-in. thick,
1 lb density fiberglass insulation. Fiberglass
insulation shall be bonded with a thermosetting
resin (8 to 12% by weight nominal, phenol
formaldehyde typical), and coated with an
acrylic or other material that meets the NFPA
90 flame retardance requirements and has an
R Value of 3.70. Aluminum foil-faced fiberglass insulation shall be used in the gas heat
compartment.
3. Cabinet panels shall have minimum 1/2-in.
thick, 1.5-lb. density insulation. Cabinet panels
shall be easily removable for servicing.
4. Filters shall be accessible through an access
panel.
5. Holes shall be provided in the base rails (minimum 14 gage) for rigging shackles and level
travel and movement during overhead rigging
operations.
6. Fork lift slots shall be available from two sides of
the unit (end and side).
7. Unit shall contain a sloped drain pan, to prevent standing water from accumulating. Pan
shall be fabricated of epoxy powder coated
steel.
C. Fans:
1. Indoor blower (evaporator fan):
a. Centrifugal supply air blower shall have pillow-block ball bearings and adjustable belt
drive. Blower assembly shall slide out of unit
for servicing.
b. Fan wheel shall be made from steel with a
corrosion resistant finish. It shall be a
dynamically balanced, double-inlet type with
forward-curved blades.
c. The indoor fan system (blower wheels,
motors, belts, and both bearings) shall slide
out for easy access.
2. Condenser fans shall be of the direct-driven
propeller type, with corrosion-resistant blades
riveted to corrosion-resistant steel supports.
They shall be dynamically balanced and discharge air upwards. Condenser fan motors shall
be totally enclosed and be of a shaft down
design.
D. Compressor(s):
1. Fully hermetic, scroll type, internally protected.
2. Factory spring-shock mounted and internally
spring mounted for vibration isolation.

F.

G.

H.

I.

including fin edges. Superior hardness characteristics of 2H per ASTM D3363-92A and
cross-hatch adhesion of 4B-5B per ASTM
D3359-93. Impact resistance shall be up to
160 in./lb (ASTM D2794-93). Humidity and
water immersion resistance shall be up to minimum 1000 and 250 hours respectively (ASTM
D2247-92 and ASTM D870-92). Corrosion
durability shall be confirmed through testing to
be no less than 1000 hours salt spray per
ASTM B117-90. Coil construction shall be
copper fins mechanically bonded to copper
tubes with copper tube sheets. Galvanized steel
tube sheets shall not be acceptable. A polymer
strip shall prevent coil assembly from contacting
sheet metal coil pan to maintain coating integrity and minimize corrosion potential between
coil and pan.
Refrigerant Components:
Each refrigerant circuit shall include:
1. Thermostatic expansion valve (TXV) with
removable power element.
2. Filter driers.
3. Gage port and connections on suction and discharge.
Filter Section:
Standard filter section shall consist of factoryinstalled 2-in. thick throwaway fiberglass filters.
Controls and Safeties:
1. Electro-Mechanical Control:
a. Economizer control (optional).
b. Capacity control (2-step).
c. Unit shall be complete with self-contained
low-voltage control circuit.
2. Safeties:
a. Unit shall incorporate a solid-state compressor lockout which provides optional reset
capability at the space thermostat, should
any of the following safety devices trip and
shut off compressor:
1) Compressor lockout protection provided
for either internal or external overload.
2) Low-pressure protection.
3) Freeze protection (evaporator coil).
4) High-pressure protection (high pressure
switch or internal).
Operating Characteristics:
1. Unit shall be capable of starting and running at
125 F ambient outdoor temperature per maximum load criteria of ARI Standard 360.
2. Unit with standard controls will operate in cooling down to an outdoor ambient temperature of
40 F.
3. Size 18 and 20 ton units shall have 3 fully independent refrigerant circuits to allow for 33%
capacity per circuit.

285

50HJ

3. On electrically and mechanically independent


refrigerant circuits.
4. Reverse rotation protection capability.
5. Crankcase heaters shall only be activated during
compressor OFF mode.
E. Coils:
1. Standard evaporator and condenser coils shall
have copper or aluminum plate fins mechanically bonded to seamless internally grooved
copper tubes with all joints brazed.
2. Coils shall be leak tested at 150 psig (1034 kPa)
and pressure tested at 450 psig (3103 kPa).
3. Optional pre-coated aluminum-fin coils shall
have a durable epoxy-phenolic coating to provide protection in mildly corrosive coastal environments. Coating shall be applied to the
aluminum fin stock prior to the fin stamping
process to create an inert barrier between the
aluminum fin and copper tube. Epoxy-phenolic
barrier shall minimize galvanic action between
dissimilar metals.
4. Copper-fin coils shall be constructed of copper
fins mechanically bonded to copper tubes and
copper tube sheets. Galvanized steel tube
sheets shall not be acceptable. A polymer strip
shall prevent coil assembly from contacting the
sheet metal coil pan to minimize potential for
galvanic corrosion between coil and pan. All
copper construction shall provide protection in
moderate coastal environments.
5. E-Coated aluminum-fin coils shall have a flexible epoxy polymer coating uniformly applied to
all coil surface areas without material bridging
between fins. Coating process shall ensure
complete coil encapsulation. Color shall be high
gloss black with gloss 60 deg of 65 to 90%
per ASTM D523-89. Uniform dry film thickness from 0.8 to 1.2 mil on all surface areas
including fin edges. Superior hardness characteristics of 2H per ASTM D3363-92A and
cross-hatch adhesion of 4B-5B per ASTM
D3359-93. Impact resistance shall be up to
160 in./lb (ASTM D2794-93). Humidity and
water immersion resistance shall be up to minimum 1000 and 250 hours respectively (ASTM
D2247-92 and ASTM D870-92). Corrosion
durability shall be confirmed through testing to
be no less than 1000 hours salt spray per
ASTM B117-90. Coil construction shall be aluminum fins mechanically bonded to copper
tubes.
6. E-Coated copper-fin coils shall have a flexible
epoxy polymer coating uniformly applied to all
coil surface areas without material bridging
between fins. Coating process shall ensure
complete coil encapsulation. Color shall be high
gloss black with gloss 60 deg of 65 to 90%
per ASTM D523-89. Uniform dry film thickness from 0.8 to 1.2 mil on all surface areas

Guide specifications 50HJ020-028 (cont)

50HJ

J. Electrical Requirements:
All unit power wiring shall enter unit cabinet at a single location.
NOTE: On 208/230 v units using 75-kW heaters,
separate wiring is required.
K. Motors:
1. Compressor motors shall be cooled by refrigerant gas passing through motor windings and
shall have line break thermal and current overload protection.
2. All fan motors shall have permanently lubricated, sealed bearings and inherent automaticreset thermal overload protection or manual
reset calibrated circuit breakers.
3. All indoor-fan motors 5 hp and larger shall
meet the minimum efficiency requirements as
established by the Energy Policy Act of 1992
(EPACT), effective October 24, 1997.
L. Special Features:
Certain features are not applicable when the features designated * are specified. For assistance in
amending the specifications, contact your local
Carrier Sales Office.
1. Full Perimeter Roof Curbs (Horizontal and
Vertical):
a. Formed of 14-gage galvanized steel with
wood nailer strip and shall be capable of
supporting entire unit weight.
b. Permits installing and securing ductwork to
curb prior to mounting unit on the curb.
c. Retrofit roof curb kit shall be available for fit
up to existing Carrier DP, DR, TJ roof curbs.
*
2. Integrated Economizers:
a. Integrated integral modulating type capable
of simultaneous economizer and compressor
operation.
b. Available as a factory-installed option in vertical supply/return configuration only. (Available as a field-installed accessory for
dedicated horizontal and/or vertical supply
return configurations.)
c. Includes all hardware and controls to provide
cooling with outdoor air.
d. Equipped with low-leakage dampers, not to
exceed 2% leakage at 1 in. wg pressure
differential.
e. Capable of introducing up to 100% outdoor
air.
f. EconoMi$er IV shall be equipped with a
barometric relief damper.
g. Designed to close damper(s) during loss-ofpower situations with spring return built into
motor.
h. Dry bulb outdoor-air temperature sensor
shall be provided as standard. Outdoor air
sensor set point is adjustable and shall range

286

905

from 40 to 100 F. For the EconoMi$er IV,


the return air sensor, indoor enthalpy sensor,
and outdoor enthalpy sensor shall be provided as field-installed accessories to provide
enthalpy control, differential enthalpy control, and differential dry bulb temperature
control.
i. The EconoMi$er IV shall have a gear-driven
parallel blade design.
j. EconoMi$er IV microprocessor control shall
provide control of internal building pressure
through its accessory power exhaust function. Factory set at 100%, with a range of
0% to 100%.
k. EconoMi$er IV Microprocessor Occupied
Minimum Damper Position Setting maintains the minimum airflow into the building
during occupied period providing design
ventilation rate for full occupancy (damper
position during heating). A remote potentiometer may be used to override the set
point.
l. EconoMi$er IV Microprocessor Unoccupied
Minimum Damper Position Setting The
EconoMi$er IV dampers shall be completely
closed when the unit is in the occupied
mode.
m. EconoMi$er IV Microprocessor IAQ/DCV
control modulates the outdoor-air damper to
provide ventilation based on the optional 2
to 10 vdc CO2 sensor input.
n. Compressor lockout sensor (opens at 35 F,
closes at 50 F).
o. Actuator shall be direct coupled to economizer gear, eliminating linkage arms and
rods.
p. Control LEDs:
1) When the outside air damper is capable
of providing free cooling, the Free
Cool LED shall illuminate.
2) The IAQ LED indicates when the module is on the DCV mode.
3) The EXH LED indicates when the
exhaust fan contact is closed.
q. Remote Minimum Position Control A
field-installed accessory remote potentiometer allows the outdoor air damper to be
opened or closed beyond the minimum
position in the occupied mode for modified
ventilation.
* 3. Barometric Relief Damper Package:
a. Package shall include damper, seals, hardware, and hoods to relieve excess internal
pressure.
b. Damper shall close due to gravity upon unit
shutdown.

905

13.

14.

15.

16.

17.

18.

detected. The smoke detector shall be factory


installed in the return air section or shall be
available as a field-installed accessory.
Two-Position Damper:
The damper shall admit up to 25% outdoor air
and shall close upon shutdown. The package
shall include a single-blade damper and motor.
Manual Damper:
The damper shall have a manually adjustable
outside air intake for up to 33% outside air.
Motor/Drive Combinations:
Low, mid-low, mid-high and high motor/drive
combinations are available to match evaporator
fan performance with each application.
Outdoor Air Enthalpy Sensor (EconoMi$er IV):
The outdoor air enthalpy sensor is used to
sense outdoor air enthalpy for the EconoMi$er
IV device. The outdoor air humidity sensor, in
conjunction with the standard outdoor air temperature sensor, shall be used with the
EconoMi$er IV device to provide outdoor
enthalpy. Outdoor air enthalpy shall be calculated by the EconoMi$er IV device from the
outdoor air temperature and humidity readings.
When the outdoor air enthalpy sensor is
installed, the EconoMi$er IV can perform Outdoor Air Enthalpy control. With the additional
installation of an accessory return air temperature sensor and return air enthalpy sensor, differential enthalpy control can also be
performed.
Return Air Enthalpy Sensor (EconoMi$er IV):
The return air enthalpy sensor is used to sense
return air enthalpy for the EconoMi$er IV
device. The return air enthalpy sensor, in conjunction with the accessory return air temperature sensor, shall be used with the EconoMi$er
IV device to provide return air enthalpy. Return
air enthalpy shall be calculated by the
EconoMi$er IV device from the return air temperature and humidity readings. With the additional installation of an accessory return air
temperature sensor and outdoor air enthalpy
sensor, differential enthalpy control can also be
performed.
Return Air Temperature Sensor (EconoMi$er
IV):
The return air temperature sensor is used to
sense return air temperature for the EconoMi$er
IV device. When the return air temperature sensor is installed, the EconoMi$er IV can perform
Differential Temperature control. The return air
temperature sensor, in conjunction with the
accessory return air enthalpy sensor, shall be
used with the EconoMi$er IV device to provide
return air enthalpy. Return air enthalpy shall be
calculated by the EconoMi$er IV device from the
return air temperature and humidity readings.
287

50HJ

* 4. Power Exhaust:
Package shall include an exhaust (centrifugal
style) fan, 1 Hp 208-230, 460 v (factory-wired
for 460 v) direct-drive motor, and damper for
vertical flow units with economizer to control
over-pressurization of building
* 5. Thermostats and Subbases:
Thermostats and subbases shall provide staged
heating and cooling in addition to automatic (or
manual) changeover and fan control.
* 6. Electronic Programmable Thermostat:
Unit shall be capable of using deluxe fullfeatured electronic thermostat.
7. Convenience Outlet:
Outlet shall be factory-installed and internally
mounted with an externally accessible 115-v,
15 amp GFI, female receptacle with hinged
cover. A step-down transformer shall be
included so no additional wiring is necessary.
8. Non-Fused Disconnect Switch:
Switch shall be factory-installed, internally
mounted, NEC and UL approved. Non-fused
switch shall provide unit power shutoff. Switch
shall be accessible from outside the unit and
shall provide power off lockout capability.
9. Electric Heater Package:
a. Fully assembled for installation. The packages are designed in accordance with UL
safety standards 1995 and listed by ETL.
Heater construction approved by UL 5306.
b. Heater element open coil resistance wire,
nickel-chrome alloy, 0.29 inches inside
diameter, strung through ceramic insulators
mounted on metal frame. Coil ends are
staked and welded to terminal screw slots.
c. Heater assemblies are provided with integral
fusing for protection of internal heater circuits not exceeding 48 amps each.
d. Auto reset thermo limit controls, magnetic
heater contactors (24 v coil) and terminal
block all mounted in electric heater control
box (minimum 18 ga. Galvanized steel)
attached to end of heater assembly.
10. Hail Guard, Condenser Coil Grille:
Hail guard, coil grille shall protect the condenser
coil from hail, flying debris, and damage by large
objects without increasing unit clearances.
11. Horizontal Kit:
Horizontal kit shall contain all the necessary
hardware to convert a vertical airflow unit to a
horizontal airflow unit.
The unit shall also be available as a horizontal
airflow unit directly from the factory.
12. Return Air Smoke Detector:
The smoke detector shall send input to the controller to shut down the unit in case smoke is

Guide specifications 50HJ020-028 (cont)

50HJ

detected. The smoke detector shall be factory


installed in the supply air section or shall be
available as a field-installed accessory.
22. Supply and Return Air Smoke Detector:
The smoke detector shall send input to the controller to shut down the unit in case smoke is
detected. The smoke detector shall be factory
installed in the supply and return air sections or
shall be available as a field-installed accessory.
23. Condensate Overflow Switch:
The condenser overflow switch shall close when
the condensate level in the pan rises above
switch.
24. Hinged Panel Option:
Hinged panel option provide hinged access
panels for the filter, compressor, evaporator
fan, and control box areas. Filter hinged panels
permit tool-less entry for changing filters. Each
hinged panel is permanently attached to the

With the additional installation of an accessory


return air enthalpy sensor and outdoor air
enthalpy sensor, differential enthalpy control can
also be performed.
19. Indoor Air Quality (CO2) Room Sensor
(EconoMi$er IV):
Sensor shall have the ability to provide demand
ventilation control through the EconoMi$er IV.
The IAQ sensor shall be wall mounted with an
LED display in parts per million. The set point
shall have adjustment capability.
20. Return Air CO2 Sensor (EconoMi$er IV):
Sensor shall have the ability to provide demand
ventilation control through the EconoMi$er IV.
The IAQ sensor shall be duct mounted. The set
point shall have adjustment capability.
21. Supply Air Smoke Detector:
The smoke detector shall send input to the controller to shut down the unit in case smoke is

288

905

Controls
Advanced Control Functions
Smoke Detection
Optimal Start (90.1)
Unoccupied Free Cool
Smart Staging and Optimal Staging
Network Protocol
CCN
Internet Ready 38.4 K baud rate
Diagnostics/Advanced Service Features
Diagnostics
Onboard display
Scheduling
Via Communicating Stat
User Interface
Navigator (LEN protocol)
LID2B (CCN)
PC with Carrier software (CCN)

PremierLink Direct Digital controls The PremierLink Direct Digital Controls (DDC) require the use of a
Carrier electronic thermostat or a CCN connection for
time broadcast to initiate its internal timeclock. This is necessary for broadcast of time of day functions (occupied/
unoccupied).
PremierLink Features:
Equipment Control Functions
Cooling Stages
Heating Stages
Indoor-Fan Motor
4-Way Valve
Economizer Control Functions
Dry Bulb Control
Enthalpy Control
Differential Enthalpy
Power Exhaust

CCN POINTS FOR PREMIERLINK CONTROL


DESCRIPTION
Space Temperature
Supply Air Temperature
Outside Air Temperature
Control Setpoint
Cooling % Total Capacity
Heating % Total Capacity
Economizer Active
Supply Fan Relay
Supply Fan Status
Economizer Position
Current Min Damper Pos
Filter Status
Remote Occupied Mode
Heat Stage 1
Heat Stage 2
Heat 3/Exhaust/Rev Valve
Enthalpy
Indoor Air Quality
Indoor Air Quality Setpt
Outdoor Air Quality
Fire Shutdown
SPT Offset
Compressor 1
Compressor 2
Compressor Safety

STATUS
xxx.x
xxx.x
xxx.x
xxx.x
xxx
xxx
No/Yes
Off/On
Off/On
xxx.x
xxx.x
Clean/Dirty
Off/On
Off/On
Off/On
Off/On
Low/High
xxxx.x
xxxx.x
xxxx.x
Normal/Alarm
xx.x
Off/On
Off/On
Off/On

UNITS
dF
dF
dF
dF
%
%

%
%

^F

POINT
SPT
SAT
OAT
CLSP
CCAP
HCAP
ECOS
SF
SFS
ECONPOS
IQMP
FLTS
RMTOCC
HS1
HS2
H3_EX_RV
ENTH
IAQI
IAQS
OAQ
FSD
STO
CMP1
CMP2
CMPSAFE

LIMITS
40.0 to 245.0 dF
40.0 to 245.0 dF
40.0 to 245.0 dF
0 to 100 %
0 to 100 %
0 to 1
0 to 1
0 to 1
0.0 to 100.0 %
0.0 to 100.0 %
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0.0 to 5000.0
0.0 to 5000.0
0.0 to 5000.0
0 to 1
15.0 to 15.0 ^F
0 to 1
0 to 1
0 to 1

ACCESS
R/W
R/W
R/W
R
R
R
R
R/W
R
R/W
R
R/W
R/W
R
R
R
R/W
R/W
R
R/W
R/W
R/W
R
R
R

289

Cool

Warm

290
Cool

Warm

BUILDING MECHANICAL ROOM

T-56
SENSOR

TM016 WITH
PREMIERLINK
CONTROL

T-56
SENSOR

PC

3 WIRE COM BUS

3RD PARTY
CONTROL

HJ014 WITH
PREMIERLINK
CONTROL

ASCII

Cool

T-56
SENSOR

RS
-48
5

LID2B

DATA LINK

COMFORT
NETWORK

OR

OR

3 WIRE COM BUS


(AT ROOFTOP LEVEL)

RS232, RS485 ADAPTOR

RS-2
MO 32 TO
DEL RS
485 - 485
S D9
R

RS
-23
2

Carrier

Warm

TM004 WITH
PREMIERLINK
CONTROL

CARRIER COMFORTLINK/PREMIERLINK CONTROLS

Cool

Warm

T-56
SENSOR

HG016 WITH
COMFORTLINK
CONTROL

Controls (cont)

TYPICAL PREMIERLINK CONTROLS WIRING (Sizes 004-014)

BLK
RED

VIO

OAT

VIO

TB - 2

HK50AA039

BLU

PNK

BRN

BLU

BRN

VIO

BRN
ORN

J6
ANAL OG

SAT
PNK

BLK

BLK
RED
BLU
YEL
WHT

10

10

Space Temp./ Set


Point Adjustment

12

12

BLK

BRN

RED

BRN

BLU

ORN

BRN
BLU
GRN

RED

Indoor Air
Quality Sensor

YEL
J4
DISCRETE

BLU

11

J5
0 - 20 mA IN

YEL

11

PremierLink

PNK
BRN

BLU
WHT

Outdoor Air
Quality Sensor
Power Exhaust/Energy Recycler

PNK
J9
0-20 mA

J2
J1
PWR COMMS

GRA
GRA

J8
Relays

GRA

TB - 3
ORN

RMTOCC

PNK

TR1

SR

PNK
GRN

GRA

WHT GRA

BRN
BLK

TB - 1
R
1

RED

GRA

FSD

BLU

SFS

WHT

Y2

PNK

W1

ORN

RED

W2

PNK

WHT

BLK

Y1

OUTDOOR AIR
ENTHALPY SENSOR

CCN
Comm.

BLK

Economi$er2
4 - 20mA

RED

BRN

PNK

RED

YEL

GRAY
GRAY

ORN ORN

ORN
RED

CMPSAFE

TR

J7
PP/MP

ORN

WHT

RETURN AIR
ENTHALPY
SENSOR

RTU Terminal
Board

RED
BRN

COMMS
OAT

PWR

RTU

SAT

TB

LEGEND
Communications
Outdoor Air Temperature Sensor
Power
Rooftop Unit
Supply Air Temperature Sensor
Terminal Block

291

292

Y2

W1

W2

Y2

W1

W2

SFS

NOT USED

RMTOCC

*If PremierLink control is in thermostat mode.


TB2 terminal designations for 24 vac discrete inputs. Default is for DDC control.

FSD

W2

W1

Y2

Y1

12

WHT

12

RED

RED

2
PL1

PL1-2

BRN

RED

BRN

WHT

BLK

PWR
J1

4-20ma
ECONO
MOTOR

ECONOMIZER
50TJ401148
(CRECOMZR010B00)

TB2-C

BRN

ENTH

NOT USED

BRN
GRAY

RED

ORN

ECONO
PLUG

PL1-1

BLK

FIELD
THERMOSTAT*

BRN

26

25

RED

PNK

SFS

FSD

SWITCH
POSITION 0
POSITION 1

CCN/LEN
+
1

0
1234

RED

NOT
USED

PL1-12

PNK
FROM
PL1-9

PL1

BLU

RED

WHT

ORN
FROM
IGC-W

RED

W2

VIO
FROM
MGV-W2

MGV

ORN

IGC

RED

RED
FROM
IGC-R

RED

HS3/
EXH/
PWR
RVS
PNK ORN RED
HS2

RED

PNK

WHT

HS1

RED

BLU

IGC

RELAYS

YEL

CMP1 CMP2
GRN

FAN

RELAYS

LEGEND
Compressor Lockout
Compressor
Economizer
Enthalpy Sensor
Integrated Gas Unit Controller
Main Gas Valve
Outdoor Air Temperature Sensor
Plug
Supply Air Temperature Sensor
Space Temperature Sensor
Terminal Block

BLU
FROM
PL1-8

8
PL1

WHT
OR
BLK
FROM
IGC-G

RED

YEL

J8

LOAD FACTORY DEFAULTS ON POWERUP

CUT FOR DUAL


TRANSFORMER
EQUIPMENT

4
NO ACTION

CCN

PremierLink
Control

1
LEN

NOT
J7 USED

IGC

GRN

BRN VIO
GND +4-20

ECONO
J9

CLO

CMP

ECONO
ENTH
IGC

MGV

OAT

PL

SAT

SPT

TB

FROM 24V
UNIT
TRANSFORMER

ECONO

SERVICE/
NAVIGATOR PORT

J3

CUT TO ISOLATE POWER SUPPLY TO CONTROLLER

VIO

RED

J2

RED

ENTH

W2

W1

Y2

Y1

BLK

TB2

Y1

Y1

BRN

ORN

24

RED

WHT

23

22

21

RMTOCC

CMPSAFE

RED

RED
ORN

WHT
RED
PNK

RED
BLU
RED

TSTAT CONTROL
GRN
RED
YEL

WHT

CMP SAFE

TB2

W2

TRAN1

RED

RED

RED

BLU

RED

YEL

RED

20

19

18

17

16

GRN

DDC
CONTROL

OAQ

COM

IAQI

COM

DISCRETE

TSTAT CONTROL

WHT

Y2
W1

RED

PNK

RED

RED

RED

15

BLU

BRN

RED

BRN

VIO

J4

WHT

BLU

YEL

GRN

14

13

12

11

10

OAT

COM

SAT

COM

0-20mA IN

Y1

BRN
BLU

RED

BRN

BRN

ORN

BRN

J5
RED

DDC CONTROL

PNK

VIO

BRN

ANALO G

VIO

BRN

BRN

STO

DISCRETE

CLO1

BLU

PL1 - 6

ORN

BLK

SPT
COM

J4

OAT

SAT

PL1 - 5

GRN
WHT

BRN

BRN

J6

BLK

BLU

BLUE

TYPICAL PREMIERLINK CONTROLS WIRING (50HJ015,017 AND 50TJ016-028)

Controls (cont)

Operating sequence, size 004-014 units


Cooling, units without economizer When thermostat calls for cooling, terminals G and Y1 are energized.
The indoor (evaporator) fan contactor (IFC) and compressor contactor no. 1 (C1) are energized, and evaporator-fan
motor (IFM), compressor no. 1, and condenser fan(s) start.
The liquid line solenoid valve for compressor no. 1 is deenergized open. The condenser-fan motor(s) runs continuously while unit is cooling. For units with 2 stages of
cooling, if the thermostat calls for a second stage of cooling by energizing Y2, compressor contactor no. 2 (C2) is
energized and compressor no. 2 starts.
Heating, units without economizer (units with electric heat) Upon a call for heating through W1, indoor
(evaporator) fan contactor (IFC) and heater contactor no. 1
(HC1) are energized. On units equipped for 2 stages of
heat, when additional heat is needed, heater contactor no.
2 is energized through W2.
Cooling, units with EconoMi$er IV When free
cooling is not available, the compressors will be controlled
by the zone thermostat. When free cooling is available, the
outdoor-air damper is modulated by the EconoMi$er IV
control to provide a 50 to 55 F mixed-air temperature into
the zone. As the mixed-air temperature fluctuates above
55 or below 50 F, the dampers will be modulated (open or
close) to bring the mixed-air temperature back within
control.
If mechanical cooling is utilized with free cooling, the
outdoor-air damper will maintain its current position at the
time the compressor is started. If the increase in cooling
capacity causes the mixed-air temperature to drop below
45 F, then the outdoor-air damper position will be
decreased to the minimum position. If the mixed-air temperature continues to fall, the outdoor-air damper will
close. Control returns to normal once the mixed-air temperature rises above 48 F.
If optional power exhaust is installed, as the outdoor-air
damper opens and closes, the power exhaust fans will be
energized and deenergized.
If field-installed accessory CO2 sensors are connected to
the EconoMi$er IV control, a demand controlled ventilation strategy will begin to operate. As the CO2 level in the
zone increases above the CO2 set point, the minimum
position of the damper will be increased proportionally. As
the CO2 level decreases because of the increase in fresh
air, the outdoor-air damper will be proportionally closed.
For EconoMi$er IV operation, there must be a thermostat call for the fan (G). If the unit is occupied and the fan is
on, the damper will operate at minimum position. Otherwise, the damper will be closed.
When the EconoMi$er IV control is in the occupied
mode and a call for cooling exists (Y1 on the thermostat),
the control will first check for indoor fan operation. If the
fan is not on, then cooling will not be activated. If the fan is
on, then the control will open the EconoMi$er IV damper
to the minimum position.
On the initial power to the EconoMi$er IV control, it will
take the damper up to 21/2 minutes before it begins to
position itself. Any change in damper position will take up

to 30 seconds to initiate. Damper movement from full


closed to full open (or vice versa) will take between 11/2
and 21/2 minutes.
If free cooling can be used as determined from the
appropriate changeover command (switch, dry bulb,
enthalpy curve, differential dry bulb, or differential
enthalpy), then the control will modulate the dampers open
to maintain the mixed-air temperature set point at 50 to
55 F.
If there is a further demand for cooling (cooling second
stage Y2 is energized), then the control will bring on
compressor stage 1 to maintain the mixed-air temperature
set point. The EconoMi$er IV damper will be open at maximum position. EconoMi$er IV operation is limited to a
single compressor.
Heating, units with EconoMi$er IV
NOTE: The units have 2 stages of electric heat.
When the thermostat calls for one stage of heating, W1
is energized. The thermostat must be configured such that
the blower output (G) is energized when there is a W1 call
for heating. The indoor fan contactor (IFC) and first stage
electric heat contactor(s) are energized, and the indoor-fan
motor and first stage electric heater are started. The
EconoMi$er IV damper modulates to the minimum
position.
If additional heating is required, the thermostat will call
for a second stage of heating, energizing W2. This will
energize the second stage of electric heat. The
EconoMi$er IV damper modulates to the minimum
position.
When the thermostat is satisfied, the EconoMi$er IV
damper modulates closed.
Cooling, units with EconoMi$er2, PremierLink
control and a thermostat When free cooling is not
available, the compressors will be controlled by the
PremierLink control in response to the Y1 and Y2 inputs
from the thermostat.
The PremierLink control will use the following information to determine if free cooling is available:
Indoor fan has been on for at least 30 seconds.
The SPT, SAT, and OAT inputs must have valid
readings.
OAT must be less than 75 F.
OAT must be less than SPT.
Enthalpy must be LOW (may be jumpered if an
enthalpy sensor not available).
Economizer position is NOT forced.
Pre-cooling occurs when the is no call from the thermostat except G. Pre-cooling is defined as the economizer
modulates to provide 70 F supply air.
When free cooling is available the PremierLink control
will control the compressors and economizer to provide a
supply-air temperature determined to meet the Y1 and Y2
calls from the thermostat.
If optional power exhaust is installed, as the outdoor-air
damper opens and closes, the power exhaust fans will be
energized and deenergized.

905

293

Controls (cont)
If field-installed accessory CO2 sensors are connected to
the PremierLink control, a PID-controlled demand ventilation strategy will begin to operate. As the CO2 level in the
zone increases above the CO2 set point, the minimum
position of the damper will be increased proportionally. As
the CO2 level decreases because of the increase in fresh
air, the outdoor-air damper will be proportionally closed.
Heating, units with EconoMi$er2, PremierLink
control and a thermostat When the thermostat calls
for heating, terminal W1 is energized. The PremierLink
control will move the economizer damper to the minimum
position if there is a call for G and closed if there is a call
for W1 without G. The IFC and heater contactor (HC1) are
energized.
When the thermostat is satisfied and W1 is deenergized,
the IFM stops after a 45-second time-off delay unless G is
still maintained.
Cooling, units with EconoMi$er2, PremierLink
control and a room sensor When free cooling is
not available, the compressors will be controlled by
the PremierLink controller using a PID Error reduction
calculation.
The PremierLink controller will use the following information to determine if free cooling is available:
Indoor fan has been on for at least 30 seconds.
The SPT, SAT, and OAT inputs must have valid
readings.
OAT must be less than 75 F.
OAT must be less than SPT.
Enthalpy must be LOW (may be jumpered if an
enthalpy sensor is not available).
Economizer position is NOT forced.
When free cooling is available, the outdoor-air damper is
positioned through the use of a Proportional Integral (PID)
control process to provide a calculated supply-air temperature into the zone. The supply air will maintain the space
temperature between the heating and cooling set points.
The PremierLink control will integrate the compressors
stages with the economizer based on logic built into the
controller.
If an optional power exhaust is installed, as the outdoorair damper opens and closes, the power exhaust fans will
be energized and deenergized.
If field-installed accessory CO2 sensors are connected to
the PremierLink control, a PID-controlled demand ventilation strategy will begin to operate. As the CO2 level in the
zone increases above the CO2 set point, the minimum
position of the damper will be increased proportionally. As
the CO2 level decreases because of the increase in fresh
air, the outdoor-air damper will be proportionally closed.
Heating, unit with EconoMi$er2, PremierLink control and a room sensor Every 40 seconds the controller will calculate the required heat stages (maximum of
3) to maintain Supply Air Temperature (SAT) if the following qualifying conditions are met:
Indoor fan has been on for at least 30 seconds.
COOL mode is not active.
OCCUPIED, TEMP. COMPENSATED START or
HEAT mode is active.
294

SAT reading is available.


Fire shutdown mode is not active.
If all of the above conditions are met, the number of heat
stages is calculated; otherwise the required number of heat
stages will be set to 0.
If the PremierLink controller determines that heat stages
are required, the economizer damper will be moved to
minimum position if occupied and closed if unoccupied.
Cooling, units with COBRA energy recovery
The cooling changeover thermostat located on COBRA
energy recovery unit hood determines when the COBRA
energy recovery unit goes into economizer mode. When
the outdoor temperature is below the cooling set point the
unit will be in economizer mode.
In the unoccupied mode, fans are normally set for
AUTO operation, causing the fans to cycle on only as
needed for heating or cooling. If the Thermidistat device
is set for AUTO fan, the rooftop unit fan will be off
except when cooling or humidity control is required. The
COBRA energy recovery unit fans will be off except when
unit is running in the economizer mode. If the Thermidistat
fan setting is set to ON, the COBRA energy recovery
unit and rooftop unit fans will run continuously. If outdoor
air is below the outdoor air thermostat set point, the compressors are locked off and the unit operates in economizer
mode when cooling is required. If outdoor air is unsuitable
due to humidity or quality, the COBRA energy recovery
unit is off and only the rooftop unit compressor runs when
cooling is required. Note that the COBRA energy recovery
unit does not run and dampers are closed when the outdoor air is unsuitable for cooling and the mode is unoccupied. If outdoor air is suitable, first stage cooling is COBRA
energy recovery unit in economizer mode and all compressors are off. Second stage cooling adds the COBRA
energy recovery unit compressor and rooftop unit compressor no. 1.
In occupied mode, when the COBRA energy recovery
unit compressor runs in cooling mode, it is extracting heat
from the incoming outdoor air and rejecting heat to the
exhaust air. The COBRA energy recovery unit and rooftop
unit fans run continuously. On a first stage call, all compressors will be off if the outdoor air is suitable for free
cooling. Otherwise, the COBRA energy recovery unit
compressor and rooftop unit compressor no. 1 will run
whenever there is a first stage demand for cooling. On a
second stage call, the COBRA energy recovery unit
compressor and rooftop unit compressor no. 1 and 2 will
run whenever there is a demand for cooling. If there is a
demand for humidity control but not cooling, only the
COBRA energy recovery unit compressor will run. If there
is a field-installed CO2 sensor and the levels are below that
sensor set point, then the unit will operate in the unoccupied mode sequence (i.e., COBRA energy recovery unit
dampers closed and rooftop unit operation only to maintain space conditions).
Heating, units with COBRA energy recovery The
heating changeover thermostat located on the COBRA
energy recovery unit hood determines the stage 1 to stage
2 switchover point in heating mode.

In unoccupied mode, the COBRA energy recovery unit


is off and all compressors are locked off. First stage heat is
rooftop unit heat at 50%. Second stage heat is rooftop unit
heat at 100%.
In unoccupied mode, when the COBRA energy recovery
unit compressor runs in heat mode, it is extracting heat
from the exhaust air and rejecting heat to the incoming
outdoor air. So it is returning energy to the building that
otherwise would be thrown away. The COBRA energy
recovery unit and rooftop unit fans run continuously. The
rooftop unit compressors are always off. On a first stage
call, the COBRA energy recovery unit compressor is on in
heat mode. Rooftop unit heat is off if the outdoor air is
above the set point. Rooftop unit heat is on at 50% if the
outdoor air is below the set point. On a second stage call,
the COBRA energy recovery unit compressor is on in heat
mode. Rooftop unit heat is on a 50% if the outdoor air is

above the set point. Rooftop unit heat is on at 100% if the


outdoor air is below the set point.
Defrost If the temperature of the 62AQ section condenser (exhaust air) coil drops below 28 F at the defrost
thermostat (DFT) and the defrost timer is at the end of a
timed period (adjustable to 30, 50, or 90 minutes), then
the reversing valve solenoid (RVS) is energized and the
condenser fan contactor(s) are deenergized. This switches
the position of the reversing valve and shuts off the 62AQ
section condenser (exhaust air) fan. The unit continues to
defrost until the coil temperature measured at the DFT
reaches 65 F or the defrost cycle completes a 10-minute
cycle. At the end of the defrost cycle the RVS deenergizes
and the exhaust fan motor energizes to put the unit in
heating mode. If the space thermostat is satisfied during a
defrost cycle, then the 62AQ section will continue in the
Defrost mode until the defrost cycle is complete.

TYPICAL COBRA ENERGY RECOVERY UNIT AIRFLOW DIAGRAM

ROOFTOP UNIT

ENERGY RECOVERY SECTION

CONDENSER

COMPRESSOR

MIXED AIR

EVAPORATOR

EXHAUST AIR

R
O
AT
R
O
AP
EV

OUTSIDE AIR

ROOF LINE
ROOM AIR

SUPPLY AIR

THERMIDISTAT/
HUMIDISTAT

295

Controls (cont)
Operating sequence, 50HJ015,017 and
50TJ016-028 units
Cooling, units without economizer When thermostat calls for cooling, terminals G and Y1 are energized.
The indoor (evaporator) fan contactor (IFC) and compressor contactor no. 1 (C1) are energized, and evaporator-fan
motor (IFM), compressor no. 1 and condenser fan(s) start.
The condenser-fan motor(s) runs continuously while unit is
cooling. When the thermostat calls for a second stage of
cooling by energizing Y2, compressor contactor no. 2 (C2)
is energized and compressor no. 2 starts.
Heating, units without economizer (if accessory or
optional heater is installed) Upon a call for heating
through terminal W1, IFC and heater contactor no. 1
(HC1) are energized. On units equipped for 2 stages of
heat, when additional heat is needed, HC2 is energized
through W2.
Cooling, units with EconoMi$er IV When free
cooling is not available, the compressors will be controlled
by the zone thermostat. When free cooling is available, the
outdoor-air damper is modulated by the EconoMi$er IV
control to provide a 50 to 55 F mixed-air temperature into
the zone. As the mixed-air temperature fluctuates above
55 or below 50 F, the dampers will be modulated (open or
close) to bring the mixed-air temperature back within
control.
If mechanical cooling is utilized with free cooling, the
outdoor-air damper will maintain its current position at the
time the compressor is started. If the increase in cooling
capacity causes the mixed-air temperature to drop below
45 F, then the outdoor-air damper position will be
decreased to the minimum position. If the mixed-air temperature continues to fall, the outdoor-air damper will
close. Control returns to normal once the mixed-air temperature rises above 48 F.
If optional power exhaust is installed, as the outdoor-air
damper opens and closes, the power exhaust fans will be
energized and deenergized.
If field-installed accessory CO2 sensors are connected to
the EconoMi$er IV control, a demand controlled ventilation strategy will begin to operate. As the CO2 level in the
zone increases above the CO2 set point, the minimum
position of the damper will be increased proportionally. As
the CO2 level decreases because of the increase in fresh
air, the outdoor-air damper will be proportionally closed.
For EconoMi$er IV operation, there must be a thermostat call for the fan (G). If the unit is occupied and the fan is
on, the damper will operate at minimum position. Otherwise, the damper will be closed.
When the EconoMi$er IV control is in the occupied
mode and a call for cooling exists (Y1 on the thermostat),
the control will first check for indoor fan operation. If the
fan is not on, then cooling will not be activated. If the fan is
on, then the control will open the EconoMi$er IV damper
to the minimum position.
On the initial power to the EconoMi$er IV control, it will
take the damper up to 21/2 minutes before it begins to
position itself. Any change in damper position will take up
to 30 seconds to initiate. Damper movement from full
296

closed to full open (or vice versa) will take between 11/2
and 21/2 minutes.
If free cooling can be used as determined from the
appropriate changeover command (switch, dry bulb,
enthalpy curve, differential dry bulb, or differential
enthalpy), then the control will modulate the dampers open
to maintain the mixed-air temperature set point at 50 to
55 F.
If there is a further demand for cooling (cooling second
stage Y2 is energized), then the control will bring on
compressor stage 1 to maintain the mixed-air temperature
set point. The EconoMi$er IV damper will be open at maximum position. EconoMi$er IV operation is limited to a
single compressor.
Heating, units with EconoMi$er IV
NOTE: The units have 2 stages of electric heat.
When the thermostat calls for one stage of heating, W1
is energized. The thermostat must be configured such that
the blower output (G) is energized when there is a W1 call
for heating. The indoor fan contactor (IFC) and first stage
electric heat contactor(s) are energized, and the indoor-fan
motor and first stage electric heater are started.
The EconoMi$er IV damper modulates to the minimum
position.
If additional heating is required, the thermostat will call
for a second stage of heating, energizing W2. This will
energize the second stage of electric heat. The
EconoMi$er IV damper modulates to the minimum
position.
When the thermostat is satisfied, the EconoMi$er IV
damper modulates closed.
Cooling, units with EconoMi$er2, PremierLink
control and a thermostat When free cooling is not
available, the compressors will be controlled by the
PremierLink control in response to the Y1 and Y2 inputs
from the thermostat.
The PremierLink control will use the following information to determine if free cooling is available:
Indoor fan has been on for at least 30 seconds.
The SPT, SAT, and OAT inputs must have valid
readings.
OAT must be less than 75 F.
OAT must be less than SPT.
Enthalpy must be LOW (may be jumpered if an
enthalpy sensor not available).
Economizer position is NOT forced.
Pre-cooling occurs when the is no call from the thermostat except G. Pre-cooling is defined as the economizer
modulates to provide 70 F supply air.
When free cooling is available the PremierLink control
will control the compressors and economizer to provide a
supply-air temperature determined to meet the Y1 and Y2
calls from the thermostat.
If optional power exhaust is installed, as the outdoor-air
damper opens and closes, the power exhaust fans will be
energized and deenergized.
If field-installed accessory CO2 sensors are connected to
the PremierLink control, a PID-controlled demand
905

ventilation strategy will begin to operate. As the CO2 level


in the zone increases above the CO2 set point, the minimum position of the damper will be increased proportionally. As the CO2 level decreases because of the increase in
fresh air, the outdoor-air damper will be proportionally
closed.
Heating, units with EconoMi$er2, PremierLink
control and a thermostat When the thermostat calls
for heating, terminal W1 is energized. The PremierLink
control will move the economizer damper to the minimum
position if there is a call for G and closed if there is a call
for W1 without G. The IFC and heater contactor (HC1) is
energized.
When the thermostat is satisfied and W1 is deenergized,
the IFM stops after a 45-second time-off delay unless G is
still maintained.
Cooling, units with EconoMi$er2, PremierLink
control and a room sensor When free cooling is
not available, the compressors will be controlled by
the PremierLink controller using a PID Error reduction
calculation as indicated below.
The PremierLink controller will use the following information to determine if free cooling is available:
Indoor fan has been on for at least 30 seconds.
The SPT, SAT, and OAT inputs must have valid
readings.
OAT must be less than 75 F.
OAT must be less than SPT.
Enthalpy must be LOW (may be jumpered if an
enthalpy sensor is not available).
Economizer position is NOT forced.
When free cooling is available, the outdoor-air damper is
positioned through the use of a Proportional Integral (PID)
control process to provide a calculated supply-air temperature into the zone. The supply air will maintain the space
temperature between the heating and cooling set points.
The PremierLink control will integrate the compressors
stages with the economizer based on logic built into the
controller.
If an optional power exhaust is installed, as the outdoorair damper opens and closes, the power exhaust fans will
be energized and deenergized.
If field-installed accessory CO2 sensors are connected to
the PremierLink control, a PID-controlled demand ventilation strategy will begin to operate. As the CO2 level in the
zone increases above the CO2 set point, the minimum
position of the damper will be increased proportionally. As
the CO2 level decreases because of the increase in fresh
air, the outdoor-air damper will be proportionally closed.
Heating, unit with EconoMi$er2, PremierLink control and a room sensor Every 40 seconds the controller will calculate the required heat stages (maximum of
3) to maintain Supply Air Temperature (SAT) if the following qualifying conditions are met:
Indoor fan has been on for at least 30 seconds.
COOL mode is not active.
OCCUPIED, TEMP. COMPENSATED START or
HEAT mode is active.

SAT reading is available.


Fire shutdown mode is not active.
If all of the above conditions are met, the number of heat
stages is calculated; otherwise the required number of heat
stages will be set to 0.
If the PremierLink controller determines that heat stages
are required, the economizer damper will be moved to
minimum position if occupied and closed if unoccupied.
Units with MoistureMi$er dehumidification package When thermostat calls for cooling, terminals G, Y1
and Y2 and the compressor contactors C1 and C2 are
energized. The indoor (evaporator) fan motor (IFM), compressor, and outdoor (condenser) fan motor (OFM) start.
The OFM runs continuously while the unit is in cooling. As
shipped from the factory, MoistureMi$er dehumidification
circuit is always energized. If MoistureMi$er circuit modulation is desired, a field-installed, wall-mounted humidistat is
required.
If the MoistureMi$er humidistat is installed and calls for
the MoistureMi$er subcooler coil to operate, the humidistat internal switch closes. This energizes and closes the liquid line solenoid valve coil (LLSV) of the MoistureMi$er
circuit, forcing the hot liquid refrigerant of the liquid line to
enter the subcooler coil. As the hot liquid passes through
the subcooler coil, it is exposed to the cold supply airflow
coming off from the evaporator coil and the liquid is further
cooled to a temperature approaching the evaporator coil
leaving-air temperature. The state of the refrigerant leaving
the subcooler coil is a highly subcooled liquid refrigerant.
The liquid then enters a thermostatic expansion valve
(TXV) where the liquid is dropped to a lower pressure. The
TXV does not have a pressure drop great enough to
change the liquid to a 2-phase fluid. The TXV can throttle
the pressure drop of the liquid refrigerant and maintain
proper conditions at the compressor suction valve over a
wide range of operating conditions. The liquid then enters
a second fixed restrictor expansion device for a second
pressure drop to a 2-phase fluid. The liquid proceeds to the
evaporator coil at a temperature lower than normal cooling operation. This lower temperature is what increases
the latent capacity of the rooftop. The 2-phase refrigerant
passes through the evaporator and is changed into a vapor.
The air passing over the evaporator coil will become colder
than during normal operation as a result of the colder
refrigerant temperatures. However, as it passes over the
subcooler coil, the air will be warmed slightly.
As the refrigerant leaves the evaporator, the refrigerant
passes a low-pressure switch in the suction line. This lowpressure switch will de-activate the MoistureMi$er package
when the suction pressure reaches 60 psig. The lowpressure switch is an added safety device to protect against
evaporator coil freeze-up. The low-pressure switch will
only de-activate and open the liquid line solenoid valve in
the MoistureMi$er circuit. The compressors will continue
to run as long as there is a call for cooling, regardless of the
position of the low-pressure switch. The solenoid valve and
the MoistureMi$er package will be re-activated only when
the call for cooling has been satisfied, the low-pressure
switch has closed, and a new call for cooling exists. The
crankcase heaters on the scroll compressor provide
297

Controls (cont)
additional protection for the compressor due to the additional refrigerant charge in the subcooler.
When the humidistat is satisfied, the humidistat internal
switch opens cutting power to and opening the LLSV. The
refrigerant is routed back through the evaporator and the
subcooler coil is removed from the refrigerant loop.
When the thermostat is satisfied, C1 and C2 are deenergized and the compressor and OFM shut off. After a
30-second delay, the IFM shuts off. If the thermostat fan
selector switch is in the ON position, the IFM will run
continuously.

Operating sequence 50HJ020-028


Cooling, units without economizer When thermostat calls for cooling, terminals G and Y1 are energized.
Compressor contactors A1 and B1 (except 028 units) are
energized and indoor-fan motor, compressor, and outdoor
fan starts. The outdoor-fan motor runs continuously while
unit is cooling. If further cooling is required, the Y2 output
from the thermostat energizes compressor contactor C1
(B1 on 028 units).
Heating, units without economizer (if accessory or
optional heater is installed) Upon a call for heating
through terminal W1, IFC and heater contactor no. 1
(HC1) are energized. On units equipped for 2 stages of
heat, when additional heat is needed, HC2 is energized
through W2.
Cooling, units with EconoMi$er IV When free
cooling is not available, the compressors will be controlled
by the zone thermostat. When free cooling is available, the
outdoor-air damper is modulated by the EconoMi$er IV
control to provide a 50 to 55 F mixed-air temperature into
the zone. As the mixed-air temperature fluctuates above
55 or below 50 F, the dampers will be modulated (open or
close) to bring the mixed-air temperature back within
control.
If mechanical cooling is utilized with free cooling, the
outdoor-air damper will maintain its current position at the
time the compressor is started. If the increase in cooling
capacity causes the mixed-air temperature to drop below
45 F, then the outdoor-air damper position will be
decreased to the minimum position. If the mixed-air temperature continues to fall, the outdoor-air damper will
close. Control returns to normal once the mixed-air temperature rises above 48 F.
If optional power exhaust is installed, as the outdoor-air
damper opens and closes, the power exhaust fans will be
energized and deenergized.
If field-installed accessory CO2 sensors are connected to
the EconoMi$er IV control, a demand controlled ventilation strategy will begin to operate. As the CO2 level in the

298

zone increases above the CO2 set point, the minimum


position of the damper will be increased proportionally. As
the CO2 level decreases because of the increase in fresh
air, the outdoor-air damper will be proportionally closed.
For EconoMi$er IV operation, there must be a thermostat call for the fan (G). If the unit is occupied and the fan is
on, the damper will operate at minimum position. Otherwise, the damper will be closed.
When the EconoMi$er IV control is in the occupied
mode and a call for cooling exists (Y1 on the thermostat),
the control will first check for indoor fan operation. If the
fan is not on, then cooling will not be activated. If the fan is
on, then the control will open the EconoMi$er IV damper
to the minimum position.
On the initial power to the EconoMi$er IV control, it will
take the damper up to 21/2 minutes before it begins to
position itself. Any change in damper position will take up
to 30 seconds to initiate. Damper movement from full
closed to full open (or vice versa) will take between 11/2
and 21/2 minutes.
If free cooling can be used as determined from the
appropriate changeover command (switch, dry bulb,
enthalpy curve, differential dry bulb, or differential
enthalpy), then the control will modulate the dampers open
to maintain the mixed-air temperature set point at 50 to
55 F.
If there is a further demand for cooling (cooling second
stage Y2 is energized), then the control will bring on
compressor stage 1 to maintain the mixed-air temperature
set point. The EconoMi$er IV damper will be open at maximum position. EconoMi$er IV operation is limited to a
single compressor.
Heating, units with EconoMi$er IV
NOTE: The units have 2 stages of electric heat.
When the thermostat calls for one stage of heating, W1
is energized. The thermostat must be configured such that
the blower output (G) is energized when there is a W1 call
for heating. The indoor fan contactor (IFC) and first stage
electric heat contactor(s) are energized, and the indoor-fan
motor and first stage electric heater are started.
The EconoMi$er IV damper modulates to the minimum
position.
If additional heating is required, the thermostat will call
for a second stage of heating, energizing W2. This will
energize the second stage of electric heat. The
EconoMi$er IV damper modulates to the minimum
position.
When the thermostat is satisfied, the EconoMi$er IV
damper modulates closed.

Application data
Condensate drain pan

Maximum operating outdoor-air temperature

A sloped condensate drain pan is supplied on all units. The


condensate pan must be externally trapped. Condensate
drains are located on both the bottom and end of the unit.

Maximum outdoor operating temperature for cooling is


shown below (60 Hz):
50TFF004-008,012
115 F
50TFF009,014
125 F
50TJ016-025
120 F
50TJ028
125 F
50HJ004-015
125 F
50HJ017
120 F
50HJ020-028
125 F

Ductwork
All ductwork must be attached to flanges. If no flanges are
present, they must be field supplied. Secure vertical discharge ductwork to roof curb. For horizontal discharge
applications, attach ductwork to flanges. Field-supplied
flanges can be attached to horizontal discharge openings
and all ductwork attached to flanges.
NOTE: A 90-degree elbow must be installed in the supply
ductwork below the unit discharge for units equipped with
electric heat.

Thermostat
Use of 2-stage cooling thermostat is recommended for all
units equipped with economizer. A 2-stage cooling thermostat is required for size 015-028 units with integrated
economizer.

Heating-to-cooling changeover
All units are automatic changeover from heating to cooling
when automatic changeover thermostat and subbase are
used.

Airflow
Units are draw-thru on cooling and blow-thru on heating.

Maximum airflow
To minimize possibility of condensate blow-off from evaporator, airflow through units should not exceed 500 cfm/ton
(sizes 004-025) and 11,250 cfm (size 028).

Minimum airflow
Minimum airflow for cooling is 300 cfm/ton (size 004025) and 280 cfm/ton (028 units). Refer to Electric Resistance Heater Data table for minimum heating airflow.

Minimum ambient operating temperature


Minimum ambient operating temperature for 50HJ004014 standard units is 25 F. Minimum ambient operating
temperature for 50TFF004-014 is 40 F. With accessory
Motormaster I, II, or IV control, units can operate at outdoor temperatures down to 20 F.
Unit sizes 015-028 are designed to operate at outdoor
temperatures down to 40 F. With accessory Motormaster I
or Motormaster V control, units can operate at outdoor
temperatures down to 20 F.
NOTE: Under most application circumstances, if the rooftop unit is equipped with an economizer, low ambient controls are not required. Unless the outdoor air is
unsatisfactory for free cooling due to high temperature,
excessive humidity, or poor air quality, outdoor air should
be used.

Motor data
Due to Carriers internal unit design (draw-thru over the
motor), air path, and specially designed motors, the full
horsepower (maximum continuous bhp) listed in the Physical Data tables and the notes following each Fan Performance table can be utilized with extreme confidence.
Using Carrier motors to the values listed in the Physical
Data, Fan Performance, and Evaporator-Fan Motor Data
tables will not result in nuisance tripping or premature
motor failure. In addition, the unit warranty will not be
affected.

Carrier PremierLink controls


The Carrier PremierLink controls can be used with any
thermostat.

Thru-the-bottom connections
The accessory thru-the-bottom connections are needed to
ensure proper connections when routing wiring and piping
through the basepan and roof curb. This accessory is used
for electric and control power.

Field-supplied fan drives


If the factory drive sets must be changed to obtain other
wheel speeds, consult the nearest Browning Manufacturing
Co. sales office with the required new wheel speed and the
data from Physical Data tables (center distances, motor and
fan shaft diameters, motor horsepower) for a modified
drive set selection. For minor speed changes, the fan
sheave size should be changed. (Do not reduce the size of
the motor sheave; this will result in reduced belt horsepower ratings and reduced belt life.)

299

Application data (cont)


Concentric duct details
CONCENTRIC DUCT DETAILS

CONCENTRIC DUCT DISTRIBUTION

6'-2 3/8'' MAX.


5'-9 3/16'' MAX.

1'-10 11/16''
MAX.

5 3/16''
4'-6 13/16''

1'-0 3/16''

1'-7 15/16''
1'-0 3/16''
B
B

24'' MIN.

A
BAFFLE

Shaded area indicates block-off panels.


NOTE: Do not drill in this area, damage to basepan may result in
water leak.

NOTE: Dimensions A, A and B, B are obtained from field-supplied


ceiling diffuser.

Concentric ducts may only be installed on units without electric


heat. Personal injury or unit damage may result.

Condenser coil protection


Pre-coated aluminum-fin coils have a durable epoxyphenolic coating applied to the fin prior to the fin stamping
process to provide protection in mildly corrosive coastal
environments. Pre-coated coils have an inert barrier
between the aluminum fin and copper tube. This barrier
electrically disconnects the dissimilar metals to minimize
the potential for galvanic corrosion. This economical
option provides substantial corrosion protection beyond
the standard uncoated coil construction.
Copper-fin coils provide increased corrosion resistance
in moderate coastal environments where industrial air pollution is not present. All copper coils eliminate bi-metallic
construction to eliminate the potential for galvanic corrosion. Application in industrial environments is not recommended due to potential attack from sulfur, sulfur oxide,
nitrogen oxides, carbon and several other industrial airborne contaminants. In moderate seacoast environments,
copper-fin coils have extended life compared to standard
or pre-coated aluminum-fin coils.

E-Coated aluminum-fin coils undergo a precisely controlled scientific process that bonds an impermeable epoxy
coating to the specially prepared fin coil surface. E-Coating
produces a smooth, consistent coating that is less brittle,
more resilient and more durable than previous postcoating
processes. E-Coated aluminum-fin coils offer economical
protection and improved coil life in many contaminated
environments.
E-Coated copper-fin coils provide maximum protection
in virtually all environments, this option combines the continuous, impenetrable barrier of the E-Coating process
with the natural resistance of an all-copper construction.
E-Coated copper-fin coil assemblies ensure long life, even
in environments that combine harsh coastal conditions
with industrial contamination.

CONDENSER COIL PROTECTION APPLICATIONS


DESCRIPTION
(Enviro-Shield Option)
Standard, Al/Cu
Pre-Coated Al/Cu
Cu/Cu
E-Coated Al/Cu
E-Coated Cu/Cu
Al/Cu
Cu/Cu
Enviro-Shield

300

Standard, Non-Corrosive
X

Mild Coastal

ENVIRONMENT
Severe Coastal
Industrial

Combined Coastal and Industrial

X
X
X
X
Aluminum Fin with Copper Tube Coil
Copper Fin with Copper Tube Coil
Family of Coil Protection Options

LEGEND
E-Coated

Extremely Flexible and Durable Epoxy Coating Uniformly


Applied to the Coil Surfaces
Pre-Coated Epoxy Coating Applied to Fin Stock Material

EconoMi$er IV
The EconoMi$er IV factory-installed economizer package
includes a gear-driven damper system that modulates the
return air and outdoor air supply to the rooftop unit in
order to take advantage of free cooling with outdoor air
when conditions are suitable. The system utilizes industry
proven technology available for integrating the use of outdoor air for cooling with mechanical cooling for 3 through
25-ton rooftop units. The intuitive EconoMi$er IV
microprocessor-based controller optimizes and enhances
rooftop operation through reduced energy consumption,
optimal zone comfort, and efficient equipment cycling.
This is accomplished by operating the compressors when
the outdoor air temperature is too warm, integrating the
compressors with outdoor air when free cooling is available, and locking out the compressor when outdoor air
temperature is too cold. The detailed sequence of operation is described in the controls section with a brief description of selected application items here.
Thermostat interface The EconoMi$er IV control
was designed to work with conventional thermostats that
have Y1 (cooling stage 1), Y2 (cooling stage 2), W1 (heat
stage 1), W2 (heat stage 2), and G (fan). In addition, the
EconoMi$er IV will support an occupied/unoccupied
switch (typically integrated into the thermostat or Thermidistat device). When the switch is closed, it provides a
24-vac signal to the unit for occupied mode, and provides
no signal to indicate unoccupied mode. The EconoMi$er
IV control can be configured to allow different minimum
economizer damper positions and to allow the use of
mechanical cooling in the occupied mode.
Control features The EconoMi$er IV controller provides superior functionality for rooftop unit operation.
EconoMi$er IV control features are included as follows:
Remote minimum position control The EconoMi$er IV
controller can be used with a field-supplied and fieldinstalled remote minimum position control switch that will
enable and disable the EconoMi$er IV to open or close the
damper beyond the minimum position for modified ventilation, providing 2 to 10 vdc output.
NOTE: Minimum position signal takes priority over the
DCV (demand control ventilation) maximum position
signal.
Demand control ventilation (DCV) The EconoMi$er IV
has DCV capability when using an IAQ sensor. This sensor
is typically installed in the return duct or occupied space.
When implementing a DCV control scheme with the
EconoMi$er IV, the control algorithm will modulate the
position of the damper between two user-configured
damper positions, Maximum DCV Position and Minimum
Occupied position. Design airflow rates for these two
damper positions should be such that when the damper is
at the Maximum DCV position, enough fresh ventilation
air will be brought in to remove contaminants and CO2
generated by sources other than people (i.e., since in unoccupied mode). The maximum DCV position is intended to
satisfy the IAQ Base Ventilation Rate. The Minimum
Occupied position design airflow rate should be sufficient
to satisfy ventilation requirements for removing CO2 from
all sources including people at the maximum occupancy.
905

IAQ sensors EconoMi$er IV can be utilized with any


IAQ (CO2) sensor that provides a 2 to 10 vdc output. The
controller will modulate the outdoor air damper to provide
ventilation based on the sensor output and the IAQ setting
of the controller. When used, an IAQ sensor will modulate
the damper from the minimum position (base ventilation
rate based on CO2 levels) to maximum position (full occupancy ventilation rate).
Damper operation The EconoMi$er IV allows the
damper to be configured for two adjustable damper positions including maximum position and occupied minimum
positions. The two (2) position damper capability is a
unique feature of EconoMi$er IV and includes operation
flexibility as follows:
1. Minimum Occupied Position: This adjustable position
allows a minimum ventilation airflow rate through the
unit during occupied periods (base ventilation rate).
2. Demand Control Ventilation (DCV) Maximum Position: A DCV maximum occupied position is provided
when using an IAQ sensor for DCV. See DCV and
Control section for sequence. The DCV Maximum
Position limits outdoor airflow into the rooftop when
the DCV routine overrides the mixed air sensor. Setting the DCV Maximum Position of the outdoor air
damper prevents large amounts of hot or cold air into
the space.
IMPORTANT: When the DCV Maximum Position is set
below the minimum position, the minimum position
overrides the maximum position, negating most DCV
functions.
Power exhaust The EconoMi$er IV has the capability to
control one stage of power exhaust for maintaining air balance and pressurization. Control is activated based on outdoor air damper position (adjustable) factory-set at the
middle position (damper halfway open).
Compressor staging The EconoMi$er IV is an integrated economizer and has the ability to utilize simultaneous outdoor air and compressors. The EconoMi$er IV
can be configured to support economizer and compressor
operation for up to 4 compressors. Only one or two compressor operation is available with 3 to 121/2 ton units.
Changeover strategies The EconoMi$er IV controller can be configured to accommodate all available economizer control strategies that place the rooftop unit in
economizer mode including:
Switch Used when a remote signal from an energy management system will enable and disable the EconoMi$er IV
(remote enable control).
Outdoor dry bulb EconoMi$er IV will be enabled based
on the outside-air temperature. This is provided standard
with the EconoMi$er IV.
Differential dry bulb EconoMi$er IV will be enabled
whenever the outside-air temperature is lower than the
return air temperature.

301

Application data (cont)


will be suitable. In general terms, a hot and humid climate
may be a reason not to use the A curve, while a cooler climate might be more applicable for using the A or B curve.
The EconoMi$er IV has expanded outdoor air capability.
For a changeover economizer which cannot utilize simultaneous economizer and compression, both A and B curves
would potentially be undesirable since the temperature and
humidity levels are too high without compression assistance to provide effective cooling. Therefore, most
changeover economizers utilize the D curve.
Differential enthalpy The EconoMi$er IV will be enabled
based on the comparison of the enthalpy of the return air
and outside air. When the outside air enthalpy is lower than
the return side, the unit will be in economizer mode.
Using the EconoMi$er IV controller for implementing
different control changeover strategies requires the use of
different combinations of dry bulb and humidity sensors as
outlined in the EconoMi$er IV Sensor Usage table.

Outside air enthalpy EconoMi$er IV will be enabled


based on the outside air enthalpy curves as shown in the
EconoMi$er IV Changeover diagram below. The A, B, C,
and D curves shown have been in use for many years and
have been included as part of the latest ASHRAE 90.1
energy efficiency code. The curves are designed to take
into consideration both outdoor temperature and humidity.
These curves are used to set up the EconoMi$er IV controller to use the EconoMi$er IV for free cooling when the
conditions to the left of the curve exist. When the conditions are to the right of the curve, then outdoor air cooling
will not be used and the outdoor air damper position will be
set at the minimum position.
Deciding which curve is used is a function of the outdoor
climate and the type of economizer utilized. Since
EconoMi$er IV is a fully integrated economizer, the range
where outdoor air can be utilized for free cooling is
expanded and the A and B curves may be used. The control point table in the EconoMi$er IV Changeover diagram
below provides assistance for whether the A and B curves

ECONOMIZER CHANGEOVER CURVES

46

85
90
95 100 105 110
(29) (32) (35) (38) (41) (43)

44

CONTROL CONTROL POINT


APPROX. F (C)
CURVE
AT 50% RH
73 (23)
A
70 (21)
B
67 (19)
C
63 (17)
D

RE
LA
TIV
EH
UM

36

75
(24)

32

PE
R

34

PO
UN
D

IDI

DR
Y

TY

38

AI
R

(%
)

40

42

80
(27)

30

16
12

14

50
(10)

40
(4)

45
(7)

30

18

55
(13) B

40

20

60
(16)

50

22

60

70

24

65
(18)

80

10
0
90

EN
TH
AL
26 PY

2 BT

70
(21)

20

D
10

35
(2)

B A
D C
35
(2)

40
(4)

45
(7)

50
(10)

55
60
65
70
75
80
85
90
95 100 105 110
(13) (16) (18) (21) (24) (27) (29) (32) (35) (38) (41) (43)

APPROXIMATE DRY BULB TEMPERATURE F (C)

302

905

HIGH LIMIT
CURVE

ECONOMIZER SENSOR USAGE CHART


ECONOMI$ER IV WITH OUTDOOR AIR
DRY BULB SENSOR
Accessories Required
None. The outdoor air dry bulb sensor is factory installed.
CRTEMPSN002A00*
HH57AC078
HH57AC078
and
CRENTDIF004A00*

APPLICATION
Outdoor Air Dry Bulb
Differential Dry Bulb
Single Enthalpy
Differential Enthalpy
CO2 for DCV Control using a
Wall-Mounted CO2 Sensor

*CRENTDIF004A00 and CRTEMPSN002A00 accessories are used on


many different base units. As such, these kits may contain parts that will
not be needed for installation.
33ZCSENCO2 is an accessory CO2 sensor.

905

OR

CO2 for DCV Control using a


Duct-Mounted CO2 Sensor

33ZCSENCO2
33ZCSENCO2
and
33ZCASPCO2**

CRCBDIOX005A00

**33ZCASPCO2

is an accessory aspirator box required for duct-mounted


applications.
CRCBDIOX005A00 is an accessory that contains both 33ZCSENCO2
and 33ZCASPCO2 accessories.

303

Index
50HJ004-028 section 132-288
50TFF004-014 section 22-90
50TJ016-028 section 91-131
Airflow
Configuration 299
Maximum 215, 299
Minimum 68, 215, 299
Application data 299-303
ARI capacity ratings
50HJ004-014 11
50HJ015, 017 11
50HJ020-028 11
50TFF004-014 10
50TJ016-028 10
Changeover, heating to cooling 299
COBRA energy recovery units 4, 7,
261, 262, 294, 295

Concentric duct details 300


Condenser coil protection 300
Controls 289-298
Convenience outlet 17, 19, 83, 97, 153, 259
Cooling capacities
50HJ004-014 157, 158, 164-172
50HJ015, 017 159, 160, 172
50HJ020-028 161-163
50TFF004-014 30, 31
50TJ016-028 100-115
Dimensions
Accessory
50HJ004-014 147, 148
50HJ015, 017 151-153
50HJ020-028 154
50TFF004-014 26, 27
50TJ016-028 95-98
COBRA energy recovery units 149, 150
Base unit
50HJ004-014 139, 140
50HJ015, 017 145
50HJ020-028 146
50TFF004-014 24, 25
50TJ016-028 93, 94
COBRA energy recovery units 141-144
Ductwork 299
EconoMi$er IV 17, 82, 123, 301-303
50HJ004-014 257
50HJ015,017 257
50TFF004-014 82
50TJ016-028 123
EconoMi$er2 17, 82, 124
50HJ004-014 258
50HJ015,017 258
50TFF004-014 82
50TJ016-028 124
Electric heaters 17
50HJ004-014 216, 217
50HJ015, 017 214
50HJ020-028 214
50TFF004-014 68
50TJ016-028 119
COBRA energy recovery units 218-221
Electrical data
50HJ004-014 222-228
50HJ015, 017 239
50HJ020-028 240-251
50TFF004-014 69-80
50TJ016-028 120, 121
COBRA energy recovery units 229-238

Energy$Recycler 17, 18
Evaporator fan motor
Efficiency
50HJ004-014 207
50HJ015, 017 207
50TJ016-028 119
Performance
50HJ004-014 206
50HJ015, 017 207
50HJ020-028 208, 209
50TFF004-014 65
50TJ016-028 119
Fan performance tables
50HJ004-014 vertical discharge
units 174-185
50HJ004-014 horizontal discharge
units 191-202
50HJ015, 017 186, 187
50HJ020-028 188-190, 203-205
50TFF004-014 vertical discharge
units 32-48
50TFF004-014 horizontal discharge
units 49-63
50TJ016-028 116, 117
Fan rpm at motor pulley settings
50HJ004-014 209, 210
50HJ015, 017 210
50HJ020-028 210
50TFF004-014 64
50TJ016-028 118
Features/Benefits 2-4
Glycol coil 116, 173
Guide specifications
50HJ004-014 265-271
50HJ015, 017 278-283
50HJ020-028 284-288
50TFF004-014 85-90
50TJ016-028 126-131
COBRA energy recovery units 272-277
Hinged panels 17, 20, 21
Humidi-MiZer 4, 212
50HJ004-014 164-171
Humidistat 262
Indoor air quality (IAQ) 4
Maximum ambient cooling operating
temperature 299
Minimum ambient cooling operating
temperature 299
Model number nomenclature
50HJ004-014 7
50HJ015, 017 8
50HJ020-028 9
50TFF004-014 5
50TJ016-028 6
MoistureMi$er dehumidification
package 4, 108-115, 172
50HJ015, 017 172
50TJ016-028 108-115
Motormaster options 17
Options and accessories 12-21
Performance data
50HJ004-028 157-221
50TFF004-014 30-68
50TJ016-028 100-119

Carrier Corporation Syracuse, New York 13221

905

Physical data
50HJ004-014 132, 133
50HJ015, 017 134, 135
50HJ020-028 135-138
50TFF004-014 22, 23
50TJ016-028 91, 92
Piping and wiring
50HJ004-014 263
50HJ015, 017 264
50TFF004-014 84
50TJ016-028 125
Power exhaust
50HJ015, 017 152, 207
50TJ016-028 98, 119
with economizer
50HJ004-014 211
50TFF004-014 67
PremierLink controls 3, 4, 17, 289-292
Roof curb dimensions
50HJ004-014 147, 148
50HJ015, 017 151
COBRA energy recovery units 149
50HJ020-028 154
50TFF004-014 26, 27
50TJ016-028 95
Selection procedure
50HJ004-028 155, 156
50TFF004-014 28, 29
50TJ016-028 99
Service options 3
Sound data
50HJ004-014 215
50HJ015, 017 215
50HJ020-028 215
50TFF004-014 67
50TJ016-028 118
Static pressure drop
Economizer
50HJ004-014 211
50HJ015, 017 213
50HJ020-028 212
50TFF004-014 66
50TJ016-028 118
Electric heat
50HJ004-014 213
50HJ015, 017 213
50HJ020-028 214
50TFF004-014 66
50TJ016-028 118
MoistureMi$er
50HJ015, 017 213
50TJ016-028 118
Thermidistat device 261
Thermostat
Application data 299
Unit-mounted disconnect 17, 19, 83, 98, 124,
153, 259, 260

Wiring
50HJ004-014
50HJ015, 017
50HJ020-028
50TFF004-014
50TM016-028
EconoMi$er IV
EconoMi$er2

252
253
254-256
81
122
82, 123, 257
82, 124, 258

9-04

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
Book 1
Book 1 4
New
Pg 304
Catalog No. 525-00044
Printed in U.S.A.
PC 111
Form 50H,T-7PD
Replaces: 50H,T-4PD
Tab
1OP2b
Tab 1b 6b

You might also like