You are on page 1of 160

EDVN041323

Warning

ENGINEERING DATA

Ask a qualified installer or contractor to install this product. Do not try to install the product yourself.
Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.

EDVN041323

Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or
contractor to install those parts and accessories. Use of unauthorised parts and accessories or
improper installation of parts and accessories can result in water or refrigerant leakage, electrical
shock, fire or explosion.
Read the User's Manual carefully before using this product. The User's Manual provides important
safety instructions and warnings. Be sure to follow these instructions and warnings.

SPLIT

If you have any enquiries, please contact your local importer, distributor and/or retailer.

FTXS-G Series

Cautions on product corrosion


1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.
2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install
the outdoor unit close to the sea shore, contact your local distributor.

- Heat Pump FTXS-G Series

Specifications, designs and other content appearing in this brochure are current as of December 2013 but subject to change without notice.
c All rights reserved

AK

EDVN041323

Split Type
Air Conditioners
FTXS-G Series
Heat Pump

1.
2.
3.
4.

FTXS25GVMV
FTXS35GVMV
FTXS50GVMV
FTXS60GVMV
FTXS71GVMV

RXS25GVMV
RXS35GVMV
RXS50GVMV
RXS60GVMV
RXS71GVMV

Power Supply ..........................................................................................3


Functions.................................................................................................4
Specifications ..........................................................................................5
Dimensions .............................................................................................8
4.1 Indoor Unit................................................................................................8
4.2 Outdoor Unit ...........................................................................................10

5. Wiring Diagrams....................................................................................12
5.1 Indoor Unit..............................................................................................12
5.2 Outdoor Unit ...........................................................................................13

6. Piping Diagrams....................................................................................15
6.1 Indoor Unit..............................................................................................15
6.2 Outdoor Unit ...........................................................................................16

7. Capacity Tables ....................................................................................18


7.1 Heat Pump .............................................................................................18
7.2 Capacity Correction Factor by the Length of Refrigerant Piping
(Reference) ............................................................................................23

8. Operation Limit......................................................................................24
9. Sound Level ..........................................................................................25
9.1 Measuring Location ................................................................................25
9.2 Indoor Unit..............................................................................................26
9.3 Outdoor Unit ...........................................................................................28

10.Electric Characteristics..........................................................................30
11.Installation Manual ................................................................................31
11.1
11.2
11.3
11.4

Safety Precautions .................................................................................31


25/35 Class ............................................................................................32
50/60 Class ............................................................................................46
71 Class .................................................................................................60

12.Operation Manual..................................................................................74
12.1
12.2
12.3
12.4

Safety Precautions .................................................................................74


25/35 Class ............................................................................................77
50/60 Class ..........................................................................................101
71 Class ...............................................................................................125

13.Optional Accessories ..........................................................................151


13.1 Option List ............................................................................................151
13.2 <KPW937A4> Air Direction Adjustment Grille......................................152
Split Type Air Conditioners FTXS-G Series

EDVN041323

13.3 <KPW945A4> Air Direction Adjustment Grille......................................153


13.4 <KKP945A4> Drain Plug......................................................................154

Split Type Air Conditioners FTXS-G Series

EDVN041323

Power Supply

1. Power Supply

Note:

Indoor Unit

Outdoor Unit

FTXS25GVMV

RXS25GVMV

FTXS35GVMV

RXS35GVMV

FTXS50GVMV

RXS50GVMV

FTXS60GVMV

RXS60GVMV

FTXS71GVMV

RXS71GVMV

Power Supply

1 , 220 ~ 240 V, 50 Hz
1 , 220 ~ 230 V, 60 Hz

Power Supply Intake ; Outdoor Unit

Split Type Air Conditioners FTXS-G Series

Functions

EDVN041323

Basic
Function

Operation limit for cooling (CDB)

10
~ 46

10
~ 46

Operation limit for heating (CWB)

15
~ 20

15
~ 18

PAM control

Standby electricity saving

Compressor

Oval scroll compressor

Comfortable
Airflow

Comfort
Control

Operation

Functions

Inverter
(with inverter power control)

FTXS50/60/71GVMV
RXS50/60/71GVMV

FTXS50/60/71GVMV
RXS50/60/71GVMV

Category

FTXS25/35GVMV
RXS25/35GVMV

FTXS25/35GVMV
RXS25/35GVMV

2. Functions

Air-purifying filter

Photocatalytic deodorising filter

Air-purifying filter with photocatalytic


deodorising function (option)

Titanium apatite photocatalytic


air-purifying filter

z
z

Category

Health &
Clean

Functions

Swing compressor

Air filter (prefilter)

Rotary compressor

Wipe-clean flat panel

Reluctance DC motor

Washable grille

Power-airflow flap

MOULD PROOF operation

Power-airflow dual flaps

Heating dry operation

Power-airflow diffuser

Wide-angle louvres

Vertical auto-swing (up and down)

Horizontal auto-swing (right and left)

3-D airflow

COMFORT AIRFLOW operation

Auto fan speed

Indoor unit quiet operation

NIGHT QUIET mode (automatic)

OUTDOOR UNIT QUIET operation


(manual)

INTELLIGENT EYE operation


Quick warming function

Timer

Good-sleep cooling operation

24-hour ON/OFF TIMER

NIGHT SET mode

Worry Free Auto-restart (after power failure)


Reliability &
Self-diagnosis (digital, LED) display
Durability
Wiring error check function

Anti-corrosion treatment of outdoor


heat exchanger

Multi-split / split type compatible indoor


unit

Flexible power supply correspondence

Chargeless

10 m

10 m

Either side drain (right or left)

Hot-start function

Power selection

Automatic defrosting

Flexibility

Remote
Control

5-room centralised controller (option)

Remote control adaptor


(normal open pulse contact) (option)

Automatic operation

Programme dry operation

Remote control adaptor


(normal open contact) (option)

Fan only

DIII-NET compatible
(adaptor) (option)

Wireless

Wired

Lifestyle
New POWERFUL operation
Convenience (non-Inverter)
Inverter POWERFUL operation

Priority-room setting

COOL / HEAT mode lock

HOME LEAVE operation

ECONO operation

Indoor unit [ON/OFF] button

Signal receiving sign

Temperature display

Remote
Controller

Note: z : Available
: Not available

Split Type Air Conditioners FTXS-G Series

EDVN041323

Specifications

3. Specifications
50 Hz, 220 - 230 - 240 V / 60 Hz, 220 - 230 V
Indoor Unit
Model

FTXS25GVMV
RXS25GVMV

Outdoor Unit
kW
Btu/h
kcal/h
L/h
A

Capacity Rated (Min. ~ Max.)


Moisture Removal
Running Current (Rated)
Power Consumption Rated
(Min. ~ Max.)
Power Factor (Rated)
COP Rated (Min. ~ Max.)
Liquid
Piping Connections
Gas
Drain
Heat Insulation
Max. Interunit Piping Length
Max. Interunit Height Difference
Chargeless
Amount of Additional Charge of
Refrigerant
Indoor Unit
Front Panel Colour
H
M
Airflow Rate
L
SL
Type
Fan
Motor Output
Speed
Air Direction Control
Air Filter

Heating
3.4 (1.2 ~ 4.5)
11,600 (4,100 ~ 15,350)
2,920 (1,030 ~ 3,870)

4.3 - 4.1 - 3.9 / 4.3 - 4.1

Cooling
3.5 (1.2 ~ 3.8)
11,900 (4,100 ~ 12,950)
3,010 (1,030 ~ 3,260)
1.9
4.9 - 4.7 - 4.5 / 4.9 - 4.7

Heating
4.0 (1.2 ~ 5.0)
13,600 (4,100 ~ 17,050)
3,440 (1,030 ~ 4,300)

5.1 - 4.9 - 4.7 / 5.1 - 4.9

600 (300 ~ 800)

830 (290 ~ 1,340)

1,020 (300 ~ 1,200)

1,080 (290 ~ 1,550)

77.9 - 79.1 - 78.1 /


77.9 - 79.1
4.17 (4.00 ~ 3.75)

87.7 - 88.0 - 88.7 /


87.7 - 88.0
4.10 (4.14 ~ 3.36)

94.6 - 94.4 - 94.4 /


94.6 - 94.4
3.43 (4.00 ~ 3.17)

96.3 - 95.8 - 95.7 /


96.3 - 95.8
3.70 (4.14 ~ 3.23)

W/W
mm
mm
mm
m
m
m

6.4
9.5
18.0

6.4
9.5
18.0

Both Liquid and Gas Pipes


20
15
10

Both Liquid and Gas Pipes


20
15
10

g/m

W
Steps

Power Consumption (Rated)

Power Factor (Rated)

%
mm
mm
kg
kg
dB(A)
dB

W
L
kg
m/min
(cfm)
W

20

20

FTXS25GVMV
White

FTXS35GVMV
White

8.7 (307)
6.7 (237)
4.7 (166)
3.9 (138)

m/min
(cfm)

Running Current (Rated)

Temperature Control
Dimensions (H W D)
Packaged Dimensions (H W D)
Weight (Mass)
Gross Weight (Gross Mass)
Sound Pressure Level H / M / L / SL
Sound Power Level
H
Outdoor Unit
Casing Colour
Type
Compressor
Model
Motor Output
Type
Refrigerant Oil
Charge
Type
Refrigerant
Charge
H
Airflow Rate
SL
Type
Fan
Motor Output

Cooling
2.5 (1.2 ~ 3.0)
8,500 (4,100 ~ 10,200)
2,150 (1,030 ~ 2,580)
1.2
3.5 - 3.3 - 3.2 / 3.5 - 3.3

FTXS35GVMV
RXS35GVMV

9.4 (332)
7.6 (268)
5.8 (205)
5.0 (177)

Cross Flow Fan


40
5 Steps, Quiet, Auto
Right, Left, Horizontal, Downwards
Removable, Washable, Mildew Proof
0.17 - 0.16 - 0.15 /
0.17 - 0.16 - 0.15 /
0.17 - 0.16
0.17 - 0.16
35 - 35 - 35 / 35 - 35
35 - 35 - 35 / 35 - 35
93.6 - 95.1 - 97.2 /
93.6 - 95.1 - 97.2 /
93.6 - 95.1
93.6 - 95.1
Microcomputer Control
283 800 195
265 855 340
9
12
37 / 31 / 25 / 22
37 / 33 / 28 / 25

RXS25GVMV
Ivory White
Hermetically Sealed Swing Type
1YC23NXD
600
FVC50K
0.375
R-410A
1.0
33.5 (1,183)
30.2 (1,066)
23.4 (826)
28.3 (999)
Propeller
50
3.33 - 3.14 - 3.05 /
4.13 - 3.94 - 3.75 /
3.33 - 3.14
4.13 - 3.94

Running Current (Rated)

Power Consumption (Rated)

565 - 565 - 565 / 565 - 565

795 - 795 - 795 / 795 - 795

Power Factor (Rated)

77.1 - 78.2 - 77.2 /


77.1 - 78.2

87.5 - 87.7 - 88.3 /


87.5 - 87.7

Starting Current
Dimensions (H W D)
Packaged Dimensions (H W D)
Weight (Mass)
Gross Weight (Gross Mass)
Sound Pressure Level H / SL
Sound Power Level
H
Drawing No.

Note:

A
mm
mm
kg
kg
dB(A)
dB

4.3
550 765 285
589 882 363
34
40
46 / 43
61

47 / 44
62
C: 3D086402

8.9 (314)
6.9 (244)
4.8 (169)
4.0 (141)

Cross Flow Fan


40
5 Steps, Quiet, Auto
Right, Left, Horizontal, Downwards
Removable, Washable, Mildew Proof
0.19 - 0.18 - 0.17 /
0.19 - 0.18 - 0.17 /
0.19 - 0.18
0.19 - 0.18
40 - 40 - 40 / 40 - 40
40 - 40 - 40 / 40 - 40
95.7 - 96.6 - 98.0 /
95.7 - 96.6 - 98.0 /
95.7 - 96.6
95.7 - 96.6
Microcomputer Control
283 800 195
265 855 340
9
12
38 / 32 / 26 / 23
38 / 34 / 29 / 26

RXS35GVMV
Ivory White
Hermetically Sealed Swing Type
1YC23NXD
600
FVC50K
0.375
R-410A
1.0
33.5 (1,183)
30.2 (1,066)
23.4 (826)
28.3 (999)
Propeller
50
4.71 - 4.52 - 4.33 /
4.91 - 4.72 - 4.53 /
4.71 - 4.52
4.91 - 4.72
1,040 - 1,040 - 1,040 /
980 - 980 - 980 / 980 - 980
1,040 - 1,040
94.6 - 94.3 - 94.3 /
96.3 - 95.8 - 95.7 /
94.6 - 94.3
96.3 - 95.8
5.1
550 765 285
589 882 363
34
40
47 / 44
48 / 45
62
63
C: 3D086398

The data are based on the conditions shown in the table below.

Cooling
Indoor ; 27CDB / 19CWB
Outdoor ; 35CDB / 24CWB

Split Type Air Conditioners FTXS-G Series

Heating
Indoor ; 20CDB
Outdoor ; 7CDB / 6CWB

9.7 (342)
7.9 (279)
6.0 (212)
5.2 (184)

Piping Length
7.5 m

Conversion Formulae
kcal/h = kW 860
Btu/h = kW 3412
cfm = m/min 35.3

Specifications

EDVN041323

50 Hz, 220 - 230 - 240 V / 60 Hz, 220 - 230 V


Indoor Unit
Model

FTXS50GVMV
RXS50GVMV

Outdoor Unit

FTXS60GVMV
RXS60GVMV

kW
Btu/h
kcal/h
L/h

Cooling
5.0 (1.7 ~ 6.0)
17,100 (5,800 ~ 20,500)
4,300 (1,460 ~ 5,160)

Heating
5.8 (1.7 ~ 7.7)
19,800 (5,800 ~ 26,300)
4,990 (1,460 ~ 6,620)

Running Current (Rated)

7.2 - 6.9 - 6.6 / 7.2 - 6.9

Power Consumption Rated


(Min. ~ Max.)

W
%

Capacity Rated (Min. ~ Max.)


Moisture Removal

Power Factor (Rated)


COP Rated (Min. ~ Max.)
Liquid
Piping Connections
Gas
Drain
Heat Insulation
Max. Interunit Piping Length
Max. Interunit Height Difference
Chargeless
Amount of Additional Charge of
Refrigerant
Indoor Unit
Front Panel Colour
H
M
Airflow Rate
L
SL
Type
Fan
Motor Output
Speed
Air Direction Control
Air Filter

W/W
mm
mm
mm

m/min
(cfm)

W
Steps

A
W

Power Factor (Rated)

%
mm
mm
kg
kg
dB(A)
dB

W
L
kg
m/min
(cfm)
W

Running Current (Rated)

Power Consumption (Rated)

Power Factor (Rated)

Note:

1,550 (440 ~ 2,080)

1,600 (400 ~ 2,530)

1,980 (440 ~ 2,390)

2,040 (400 ~ 2,810)

97.9 - 97.7 - 97.9 /


97.9 - 97.7
3.23 (3.86 ~ 2.88)

98.3 - 98.0 - 98.0 /


98.3 - 98.0
3.63 (4.25 ~ 3.04)

97.8 - 97.8 - 98.2 /


97.8 - 97.8
3.03 (3.86 ~ 2.80)

98.6 - 98.6 - 98.8 /


98.6 - 98.6
3.43 (4.25 ~ 2.85)
6.4
12.7
18.0

Both Liquid and Gas Pipes


30
20
10

Both Liquid and Gas Pipes


30
20
10

A
mm
mm
kg
kg
dB(A)
dB

14.7 (519)
12.6 (445)
10.2 (360)
9.2 (325)

20

20

FTXS50GVMV
White

FTXS60GVMV
White
16.2 (572)
13.8 (487)
11.5 (406)
10.2 (360)

Cross Flow Fan


43
5 Steps, Quiet, Auto
Right, Left, Horizontal, Downwards
Removable, Washable, Mildew Proof
0.16 - 0.15 - 0.15 /
0.17 - 0.16 - 0.16 /
0.16 - 0.15
0.17 - 0.16
34
36
96.6 - 98.6 - 94.4 /
96.3 - 97.8 - 93.8 /
96.6 - 98.6
96.3 - 97.8
Microcomputer Control
290 1,050 238
337 1,147 366
12
17
44 / 40 / 35 / 32
42 / 38 / 33 / 30
60
58
RXS50GVMV
Ivory White
Hermetically Sealed Swing Type
2YC36BXD
1,100
FVC50K
0.65
R-410A
1.5
48.9 (1,727)
45.0 (1,589)
41.7 (1,472)
45.0 (1,589)
Propeller
53
7.04 - 6.75 - 6.45 /
7.23 - 6.94 - 6.64 /
7.04 - 6.75
7.23 - 6.94
1,516
1,564
97.9 - 97.6 - 97.9 /
98.3 - 98.0 - 98.1 /
97.9 - 97.6
98.3 - 98.0
7.4
735 825 300
792 960 390
48
53
47 / 44
48 / 45
61
62
C: 3D086399

16.2 (572)
13.9 (491)
11.5 (406)
10.0 (353)

Heating
Indoor ; 20CDB
Outdoor ; 7CDB / 6CWB

17.4 (614)
15.3 (540)
12.8 (452)
10.5 (371)

Cross Flow Fan


43
5 Steps, Quiet, Auto
Right, Left, Horizontal, Downwards
Removable, Washable, Mildew Proof
0.19 - 0.18 - 0.17 /
0.21 - 0.20 - 0.19 /
0.19 - 0.18
0.21 - 0.20
40
45
95.7 - 96.6 - 98.0 /
97.4 - 97.8 - 98.7 /
95.7 - 96.6
97.4 - 97.8
Microcomputer Control
290 1,050 238
337 1,147 366
12
17
45 / 41 / 36 / 33
44 / 40 / 35 / 32
61
60
RXS60GVMV
Ivory White
Hermetically Sealed Swing Type
2YC36BXD
1,100
FVC50K
0.65
R-410A
1.5
50.9 (1,797)
46.3 (1,635)
45.0 (1,589)
46.3 (1,635)
Propeller
53
9.01 - 8.62 - 8.23 /
9.19 - 8.80 - 8.41 /
9.01 - 8.62
9.19 - 8.80
1,940
1,995
97.9 - 97.9 - 98.2 /
98.7 - 98.6 - 98.8 /
97.9 - 97.9
98.7 - 98.6
9.4
735 825 300
792 960 390
48
53
49 / 46
49 / 46
63
63
C: 3D086400

The data are based on the conditions shown in the table below.

Cooling
Indoor ; 27CDB / 19CWB
Outdoor ; 35CDB / 24CWB

6.4
12.7
18.0

g/m

Power Consumption (Rated)

Starting Current
Dimensions (H W D)
Packaged Dimensions (H W D)
Weight (Mass)
Gross Weight (Gross Mass)
Sound Pressure Level H / SL
Sound Power Level
H
Drawing No.

Heating
7.0 (1.7 ~ 8.0)
23,900 (5,800 ~ 27,300)
6,020 (1,460 ~ 6,880)

9.4 - 9.0 - 8.6 /


9.4 - 9.0

m
m
m

Running Current (Rated)

Temperature Control
Dimensions (H W D)
Packaged Dimensions (H W D)
Weight (Mass)
Gross Weight (Gross Mass)
Sound Pressure Level H / M / L / SL
Sound Power Level
H
Outdoor Unit
Casing Colour
Type
Compressor
Model
Motor Output
Type
Refrigerant Oil
Charge
Type
Refrigerant
Charge
H
Airflow Rate
SL
Type
Fan
Motor Output

7.4 - 7.1 - 6.8 / 7.4 - 7.1

Cooling
6.0 (1.7 ~ 6.7)
20,500 (5,800 ~ 22,900)
5,160 (1,460 ~ 5,760)

9.2 - 8.8 - 8.4 /


9.2 - 8.8

Piping Length
7.5 m

Conversion Formulae
kcal/h = kW 860
Btu/h = kW 3412
cfm = m/min 35.3

Split Type Air Conditioners FTXS-G Series

EDVN041323

Specifications

50 Hz, 220 - 230 - 240 V / 60 Hz, 220 - 230 V


Indoor Unit
Model

FTXS71GVMV
RXS71GVMV

Outdoor Unit

Capacity Rated (Min. ~ Max.)


Moisture Removal
Running Current (Rated)
Power Consumption Rated
(Min. ~ Max.)
Power Factor (Rated)
COP Rated (Min. ~ Max.)
Liquid
Piping Connections
Gas
Drain
Heat Insulation
Max. Interunit Piping Length
Max. Interunit Height Difference
Chargeless
Amount of Additional Charge of
Refrigerant
Indoor Unit
Front Panel Colour
H
M
Airflow Rate
L
SL
Type
Fan
Motor Output
Speed
Air Direction Control
Air Filter
Running Current (Rated)
Power Consumption (Rated)
Power Factor (Rated)
Temperature Control
Dimensions (H W D)
Packaged Dimensions (H W D)
Weight (Mass)
Gross Weight (Gross Mass)
Sound Pressure Level H / M / L / SL
Sound Power Level
H
Outdoor Unit
Casing Colour
Type
Compressor
Model
Motor Output
Type
Refrigerant Oil
Charge
Type
Refrigerant
Charge
H
Airflow Rate
SL
Type
Fan
Motor Output
Running Current (Rated)
Power Consumption (Rated)
Power Factor (Rated)
Starting Current
Dimensions (H W D)
Packaged Dimensions (H W D)
Weight (Mass)
Gross Weight (Gross Mass)
Sound Pressure Level H / SL
Sound Power Level
H
Drawing No.

Note:

Cooling
7.1 (2.3 ~ 8.5)
24,200 (7,800 ~ 29,000)
6,110 (1,980 ~ 7,310)

10.8 - 10.4 - 9.9 / 10.8 - 10.4

kW
Btu/h
kcal/h
L/h
A

Heating
8.2 (2.3 ~ 10.0)
28,000 (7,900 ~ 34,100)
7,050 (1,980 ~ 8600)

11.6 - 11.1 - 10.6 / 11.6 - 11.1

2,360 (570 ~ 3,200)

2,520 (520 ~ 3,730)

%
W/W
mm
mm
mm

99.3 - 98.7 - 99.3 / 99.3 - 98.7


3.01 (4.04 ~ 2.66)

98.7 - 98.7 - 99.1 / 98.7 - 98.7


3.25 (4.42 ~ 2.68)
6.4
15.9
18.0

Both Liquid and Gas Pipes


30
20
10

m
m
m
g/m

20
FTXS71GVMV
White
17.4 (614)
14.6 (516)
11.9 (420)
11.2 (395)

m/min
(cfm)

W
Steps

A
W
%
mm
mm
kg
kg
dB(A)
dB

W
L
kg
m/min
(cfm)
W
A
W
%
A
mm
mm
kg
kg
dB(A)
dB

21.5 (759)
18.0 (636)
14.4 (508)
13.3 (470)

Cross Flow Fan


43
5 Steps, Quiet, Auto
Right, Left, Horizontal, Downwards
Removable, Washable, Mildew Proof
0.21 - 0.20 - 0.19 / 0.21 - 0.20
0.28 - 0.27 - 0.26 / 0.28 - 0.27
45
60
97.4 - 97.8 - 98.7 / 97.4 - 97.8
97.4 - 96.6 - 96.2 / 97.4 - 96.6
Microcomputer Control
290 1,050 238
337 1,147 366
12
17
46 / 42 / 37 / 34
46 / 42 / 37 / 34
62
62
RXS71GVMV
Ivory White
Hermetically Sealed Swing Type
2YC63BXD
1,920
FVC50K
0.75
R-410A
2.3
54.5 (1,924)
52.5 (1,854)
46.0 (1,624)
52.5 (1,854)
Propeller
66
10.59 - 10.20 - 9.71 / 10.59 - 10.20
11.32 - 10.83 - 10.34 / 11.32 - 10.83
2,315
2,460
99.4 - 98.7 - 99.3 / 99.4 - 98.7
98.8 - 98.8 - 99.1 / 98.8 - 98.8
11.6
770 900 320
900 925 390
71
79
52 / 49
52 / 49
66
66
C: 3D086401

The data are based on the conditions shown in the table below.

Cooling
Indoor ; 27CDB / 19CWB
Outdoor ; 35CDB / 24CWB

Split Type Air Conditioners FTXS-G Series

Heating
Indoor ; 20CDB
Outdoor ; 7CDB / 6CWB

Piping Length
7.5 m

Conversion Formulae
kcal/h = kW 860
Btu/h = kW 3412
cfm = m/min 35.3

Dimensions

EDVN041323

4. Dimensions
4.1

Indoor Unit

THE MARK () SHOWS PIPING DIRECTION

AIR FLOW (INDOOR)


30 MIN.

REAR

(SPACE FOR
PERFORMANCE)

FTXS25/35GVMV

800

LEFT

RIGHT

( INCLUDING
MOUNTING PLATE )
50 MIN.
(SPACE FOR
MAINTENANCE)

197
195

50 MIN.
(SPACE FOR
MAINTENANCE)

REQUIRED SPACE

SIGNAL RECEIVER
283

NAME PLATE
OPERATION LAMP
TIMER LAMP
INTELLIGENT EYE LAMP

TERMINAL BLOCK
WITH EARTH
TERMINAL

INTELLIGENT EYE SENSOR


BOTTOM

GAS PIPE 9.5 Cut


(THE LENGTH OF PIPE OUTSIDE
THE UNIT : ABOUT 390)

INDOOR UNIT ON/OFF SWITCH

FRONT PANEL FIXED SCREWS


(INSIDE)
FLAPS

ROOM TEMP. THERMISTOR (INSIDE)

DRAIN HOSE
(CONNECTING PART

I.D. 14
LIQUID PIPE 6.4 CuT

(THE LENGTH OF PIPE OUTSIDE O.D. 18


THE HOSE LENGTH OF OUTSIDE
THE UNIT : ABOUT 340)
THE UNIT IS APPROX. 440)

SIGNAL TRANSMITTER

711

17

18

BLADE ANGLE

13

800
58

49

UP/DOWN (AUTOMATIC)

60

70

65

110

WALL HOLE FOR EMBEDDED PIPING


65 HOLE

30

50
RIGHT/LEFT (MANUAL)

WIRELESS REMOTE CONTROLLER

283

10

44.5

163

FAN

44.5.

HEATING

COOLING, DRY

180

DAIKIN

WALL HOLE
65 HOLE

STANDARD LOCATIONS OF WALL HOLES

(ARC433B46)

45

3D084049A

45

AIR FLOW (INDOOR)


(FOR PERFORMANCE AND MAINTENANCE)
THE MARK () SHOWS PIPING DIRECTION
RIGHT
(SPACE FOR
MAINTENANCE)
MIN. 50

INCLUDING
INSTALLATION PLATE
240
238

OPERATION LAMP
SIGNAL RECEIVER

FLAPS

TERMINAL BLOCK WITH


EARTH TERMINAL
(INSIDE)

ROOM TEMP. THERMISTOR


(INSIDE)
INTELLIGENT EYE SENSOR
TIMER LAMP
HOME LEAVE LAMP

FRONT GRILLE FIXING SCREWS


(INSIDE)

GAS PIPE 12.7 CuT


(THE LENGTH OF PIPE OUTSIDE
THE UNIT: ABOUT 430)

DRAIN HOSE FOR VP13


(CONNECTING PART
I. D. 14. 0, O. D. 18. 0)
(THE HOSE LENGTH OF
LIQUID PIPE 6.4 CuT
OUTSIDE THE UNIT:
(THE LENGTH OF PIPE OUTSIDE
ABOUT 530)
THE UNIT: ABOUT 480)

SIGNAL
TRANSMITTER
18

1050

BLADE ANGLES

893.5

HEATING

DRY

52.5

163

155.5

HORIZONTAL BLADE
(AUTOMATIC)
COOLING

14.5

58

MODEL NAME
PLATE
290

INDOOR UNIT ON/OFF


SWITCH

MIN. 50
(SPACE FOR
MAINTENANCE)

REQUIRED SPACE

40

WIRELESS REMOTE
CONTROLLER

55

FAN

15

35

52
5
35

55

60

VERTICAL BLADE (AUTOMATIC)

5
50

5
55

15

40 10

50

WALL HOLE FOR


EMBEDDED PIPING
80 HOLE

99.5

52

10

(ARC433B70)

30

REAR

1050

290

REAR

LEFT

MIN. 30
(SPACE FOR
PERFORMANCE)

FTXS50/60GVMV

WALL HOLE
80 HOLE

STANDARD LOCATIONS OF WALL HOLES

3D077945A

55

Split Type Air Conditioners FTXS-G Series

EDVN041323

Dimensions

AIR FLOW (INDOOR)


(FOR PERFORMANCE AND MAINTENANCE)

THE MARK () SHOWS PIPING DIRECTION

RIGHT
(SPACE FOR
MAINTENANCE)
MIN.50

INCLUDING
INSTALLATION PLATE
240
238

OPERATION LAMP
SIGNAL RECEIVER

MODEL NAME
PLATE
290

INDOOR UNIT ON/OFF


SWITCH

TERMINAL BLOCK WITH


EARTH TERMINAL
(INSIDE)

ROOM TEMP. THERMISTOR


(INSIDE)

FLAPS

INTELLIGENT EYE SENSOR


TIMER LAMP
HOME LEAVE LAMP

FRONT GRILLE FIXING SCREWS


(INSIDE)

DRAIN HOSE FOR VP13


(CONNECTING PART
I.D. 14.0, O.D. 18.0)
(THE HOSE LENGTH OF
LIQUID PIPE 6.4 CuT
OUTSIDE THE UNIT:
(THE LENGTH OF PIPE OUTSIDE
ABOUT 530)
THE UNIT: ABOUT 480)
1050

GAS PIPE 15.9 CuT


(THE LENGTH OF PIPE OUTSIDE
THE UNIT: ABOUT 430)

SIGNAL
TRANSMITTER
18
HORIZONTAL BLADE
(AUTOMATIC)

893.5

HEATING

DRY

52.5

163

155.5

COOLING

BLADE ANGLES
14.5

58

MIN.50
(SPACE FOR
MAINTENANCE)

REQUIRED SPACE

40

WIRELESS REMOTE
(ARC433B70)

55

FAN

15

35

52

15

40 10

5
35

55

VERTICAL BLADE (AUTOMATIC)

5
50

5
55

50

60
WALL HOLE FOR
EMBEDDED PIPING
80 HOLE

99.5

STANDARD LOCATIONS OF WALL HOLES

52

10

CONTROLLER

30

REAR

1050

290

REAR

LEFT

MIN.30
(SPACE FOR
PERFORMANCE)

FTXS71GVMV

WALL HOLE
80 HOLE

3D077942A

55

Split Type Air Conditioners FTXS-G Series

Dimensions

4.2

EDVN041323

Outdoor Unit

574

WALL HEIGHT ON AIR OUTLET SIDE


= LESS THAN 1200

MINIMUM SPACE FOR AIR PASSAGE

4-HOLES FOR ANCHOR BOLTS


(M8 OR M10)

DRAIN OUTLET
(I.D15.9 HOSE FOR CONNECTION)

150

RXS25/35GVMV

105.5

50

50

100

50

300

50

29.5

311

150

100

13

490

HANDLE

BRAND NAME LABEL


285

12

765

63
OUTDOOR AIR THERMISTOR
MANUFACTURER' S
LABEL

LIQUID
STOP VALVE
(6.4 CuT)

105

SERVICE
PORT

165

550

WIRING
INLET

22

196
IN CASE OF REMOVING
STOP VALVE COVER

GAS STOP VALVE


(9.5 CuT)

3D077982A

DRAIN OUTLET
(I.D.15.9 HOSE FOR CONNECTION)
825

WALL HEIGHT ON AIR OUTLET SIDE


= LESS THAN 1200

MINIMUM SPACE FOR AIR PASSAGE

100

RXS50/60GVMV

78

350

580

50

50

350

100

330

300

IN CASE OF REMOVING
STOP VALVE COVER

25

10

350

50

OUTDOOR AIR TEMPERATURE


THERMISTOR

NAME PLATE
BRAND NAME LABEL

WIRING INLET

TERMINAL STRIP
WITH EARTH TERMINAL

89 64

735

4-HOLES FOR ANCHOR BOLTS


(M8 OR M10)

350

36

124

100

325

LIQUID STOP VALVE


(6.4 CuT)
SERVICE PORT

155
160

18
30
GAS STOP VALVE
(12.7 CuT)

3D077994A

10

Split Type Air Conditioners FTXS-G Series

EDVN041323

Dimensions

RXS71GVMV
MINIMUM SPACE FOR AIR PASSAGE
900
4-CUTS FOR ANCHOR BOLTS
(M12)

WALL HEIGHT ON AIR OUTLET SIDE = LESS THAN 1200


350
100

100
350

191

50

30

376

380

320
350
(345~355)

102 71
117
30

45

50

350

140

100

620

DRAIN OUTLET
I.D.25 HOSE FOR CONNECTION.

50

GAS STOP VALVE


TERMINAL STRIP
WITH EARTH TERMINAL
LIQUID STOP VALVE

OUTDOOR AIR
THERMISTOR

126

50
78
108

104

INTERCONNECTING PIPING
AND WIRING INLET

90

410

770

NAME PLATE

GAS PIPE
(15.9 SINGLE UNION)

30
67

LIQUID PIPE
(6.4 SINGLE UNION)

3D078005A

Split Type Air Conditioners FTXS-G Series

11

Wiring Diagrams

EDVN041323

5. Wiring Diagrams
5.1

Indoor Unit

FTXS25/35GVMV

3D078575B

FTXS50/60/71GVMV

3D078576B

12

Split Type Air Conditioners FTXS-G Series

EDVN041323

5.2

Wiring Diagrams

Outdoor Unit

RXS25/35GVMV

3D078579B

RXS50/60GVMV

3D078580A

Split Type Air Conditioners FTXS-G Series

13

Wiring Diagrams

EDVN041323

RXS71GVMV

3D078581C

14

Split Type Air Conditioners FTXS-G Series

EDVN041323

Piping Diagrams

6. Piping Diagrams
6.1

Indoor Unit

FTXS25/35GVMV

FTXS50/60GVMV

INDOOR UNIT

INDOOR UNIT

MUFFLER ASSY
HEAT EXCHANGER
7.0 CuT
(7.9 CuT)

7.9 CuT

6.4 CuT

THERMISTOR
ON HEAT EXCH.

6.4 CuT

HEAT EXCHANGER

6.4 CuT
THERMISTOR
ON HEAT EXCH.

FIELD PIPING
(6.4 CuT)

CROSS FLOW FAN


FIELD PIPING
(6.4 CuT)

M
FAN MOTOR

FIELD PIPING
(12.7 CuT)

9.5 CuT

FIELD PIPING
(9.5 CuT)

REFRIGERANT FLOW
COOLING
HEATING

4D078439A

CROSS FLOW FAN

M
FAN MOTOR
(12.7 CuT)

REFRIGERANT FLOW
COOLING
HEATING

4D077898A

FTXS71GVMV

INDOOR UNIT

(7.9 CuT)

HEAT EXCHANGER

THERMISTOR
ON HEAT EXCH.
FIELD PIPING
(6.4 CuT)
FIELD PIPING
(15.9 CuT)

CROSS FLOW FAN

M
FAN MOTOR
(12.7 CuT)

REFRIGERANT FLOW
COOLING
HEATING

4D077941A

Split Type Air Conditioners FTXS-G Series

15

Piping Diagrams

6.2

EDVN041323

Outdoor Unit

RXS25/35GVMV
OUTDOOR UNIT
OUTDOOR TEMPERATURE
THERMISTOR

9.5 CuT

7.0 CuT HEAT EXCHANGER


7.0 CuT

4.8 CuT

MUFFLER
WITH
FILTER

MOTOR OPERATED
VALVE
.4.0xID.2.0 CuT

HEAT EXCHANGER
THERMISTOR
4.8 CuT
6.4 CuT 6.4 CuT

MUFFLER
WITH
FILTER

9.5 CuT

PROPELLER FAN

FOUR WAY
VALVE
ON:HEATING

7.9 CuT

MUFFLER
DISCHARGE PIPE
THERMISTOR

9.5 CuT

7.9 CuT

6.4 CuT

9.5 CuT

LIQUID STOP
VALVE

9.5 CuT
COMPRESSOR

MUFFLER
WITH
FILTER

9.5 CuT

ACCUMULATOR

MUFFLER

GAS STOP
VALVE

FIELD PIPING
(6.4 CuT)

FIELD PIPING
(9.5 CuT)
REFRIGERANT FLOW
COOLING
HEATING

3D078991A

RXS50/60GVMV
OUTDOOR UNIT
HEAT EXCHANGER

7.9 CuT

OUTDOOR TEMPERATURE
THERMISTOR

7.9 CuT
7.9 CuT
7.9 CuT
7.9 CuT

CAPILLARY TUBE1

7.9 CuT

7.9 CuT 4.0 CuT

7.9 CuT

7.9 CuT 4.0 CuT


CAPILLARY TUBE2
CAPILLARY TUBE3

7.9 CuT

4.0 CuT
HEAT
EXCHANGER
THERMISTOR

4.0 CuT
CAPILLARY TUBE4

EV

MUFFLER
WITH
FILTER
6.4 CuT

PROPELLER FAN

REFRIGERANT FLOW
COOLING

6.4 CuT 6.4 CuT

12.7 CuT

HEATING

ELECTRONIC
EXPANSION
VALVE
FILTER

6.4 CuT

12.7 CuT
9.5 CuT

7.9 CuT

FOUR WAY
VALVE
ON:HEATING

12.7 CuT

12.7 CuT

MUFFLER

RECEIVER

MUFFLER
9.5 CuT

7.9 CuT
MUFFLER

6.4 CuT

LIQUID
STOP VALVE

FIELD PIPING
(6.4 CuT)

7.9 CuT
12.7 CuT
DISCHARGE PIPE
THERMISTOR
COMPRESSOR

GAS STOP VALVE


WITH SERVICE PORT

FIELD PIPING
(12.7 CuT)

3D078127A

16

Split Type Air Conditioners FTXS-G Series

EDVN041323

Piping Diagrams

RXS71GVMV
OUTDOOR UNIT
OUTDOOR TEMPERATURE
THERMISTOR

HEAT EXCHANGER (CONDENSER)


THERMISTOR
4.0 CuT
7.9 CuT

DC FAN MOTOR

9.5 CuT 9.5 CuT


DISTRIBUTOR

ELECTRONIC
RECEIVER
EXPANSION
VALVE
EV
9.5 CuT
9.5 CuT 9.5 CuT

FILTER

FILTER

4-WAY
VALVE
ON : HEATING

7.9 CuT
7.9 CuT

DISCHARGE PIPE
THERMISTOR

REFRIGERANT FLOW
COMPRESSOR
COOLING
HEATING

7.9 CuT

MUFFLER
15.9 CuT

15.9 CuT

15.9 CuT

15.9 CuT

9.5 CuT

PROPELLER FAN

LIQUID LINE
STOP VALVE

CAPILLARY TUBE

15.9 CuT

12.7 CuT

HEADER

9.5 CuT

HEAT EXCHANGER
7.9 CuT
7.9 CuT
7.9 CuT
7.9 CuT
7.9 CuT
7.9 CuT
7.9 CuT
7.9 CuT

9.5 CuT

FIELD PIPING
LIQUID (6.4 CuT)

GAS LINE
STOP VALVE

ACCUMULATOR ACCUMULATOR
15.9 CuT

15.9 CuT

FIELD PIPING
GAS (15.9 CuT)
3D078128A

Split Type Air Conditioners FTXS-G Series

17

Capacity Tables

EDVN041323

7. Capacity Tables
7.1

Heat Pump

FTXS25GVMV + RXS25GVMV (50 Hz, 220 - 230 - 240 V / 60 Hz, 220 - 230 V)
Cooling
AFR

8.7

BF

0.24

INDOOR

OUTDOOR TEMPERATURE (CDB)

EWB EDB

20

25

30

32

35

40

TC

SHC

PI

TC

SHC

PI

TC

SHC

PI

TC

SHC

PI

TC

SHC

PI

TC

SHC

PI

14.0

20

2.56

1.93

0.46

2.44

1.87

0.50

2.33

1.82

0.55

2.28

1.79

0.57

2.21

1.76

0.59

2.10

1.70

0.64

16.0

22

2.68

1.90

0.46

2.56

1.84

0.51

2.44

1.79

0.55

2.40

1.77

0.57

2.33

1.74

0.60

2.21

1.69

0.64

18.0

25

2.79

1.99

0.47

2.68

1.94

0.51

2.56

1.89

0.55

2.51

1.87

0.57

2.44

1.84

0.60

2.33

1.80

0.64

19.0

27

2.85

2.11

0.47

2.73

2.06

0.51

2.62

2.01

0.56

2.57

1.99

0.57

2.50

1.96

0.60

2.38

1.92

0.64

22.0

30

3.02

2.03

0.47

2.91

1.99

0.52

2.79

1.95

0.56

2.74

1.93

0.58

2.67

1.91

0.60

2.56

1.86

0.65

24.0

32

3.14

1.98

0.47

3.02

1.94

0.52

2.90

1.90

0.56

2.86

1.89

0.58

2.79

1.86

0.61

2.67

1.83

0.65

Heating
AFR

9.4

INDOOR

OUTDOOR TEMPERATURE (CWB)

EDB

10

TC

PI

TC

PI

TC

PI

15.0

2.29

0.70

2.67

0.74

3.06

0.77

3.52

0.81

3.82

0.84

20.0

2.17

0.72

2.56

0.75

2.94

0.79

3.40

0.83

3.71

0.86

22.0

2.12

0.73

2.51

0.76

2.89

0.80

3.35

0.84

3.66

0.86

24.0

2.08

0.74

2.46

0.77

2.85

0.80

3.31

0.84

3.61

0.87

25.0

2.05

0.74

2.44

0.77

2.82

0.81

3.28

0.85

3.59

0.88

27.0

2.01

0.75

2.39

0.78

2.77

0.82

3.24

0.86

3.54

0.88

Symbols:
AFR

: Airflow rate

BF

: Bypass factor

(m/min.)

EWB

: Entering wet bulb temp.

(C)

EDB

: Entering dry bulb temp.

(C)

TC

: Total capacity

(kW)

SHC

: Sensible heat capacity

(kW)

PI

: Power input

(kW)

TC

10

PI

TC

PI

Notes:
1. Capacities are based on the following conditions.
Corresponding refrigerant piping length : 7.5 m
Level difference : 0 m
2.
shows nominal (rated) capacities and power input.

3D086268

18

Split Type Air Conditioners FTXS-G Series

EDVN041323

Capacity Tables

FTXS35GVMV + RXS35GVMV (50 Hz, 220 - 230 - 240 V / 60 Hz, 220 - 230 V)
Cooling
AFR

8.9

BF

0.24

INDOOR

OUTDOOR TEMPERATURE (CDB)

EWB EDB

20

25

30

32

35

40

TC

SHC

PI

TC

SHC

PI

TC

SHC

PI

TC

SHC

PI

TC

SHC

PI

TC

SHC

PI

14.0

20

3.31

2.33

0.78

3.31

2.33

0.86

3.26

2.31

0.93

3.19

2.27

0.96

3.10

2.22

1.01

2.93

2.13

1.08

16.0

22

3.75

2.44

0.79

3.58

2.35

0.86

3.42

2.27

0.94

3.36

2.24

0.97

3.26

2.19

1.01

3.10

2.11

1.09

18.0

25

3.91

2.52

0.79

3.75

2.44

0.87

3.58

2.37

0.94

3.52

2.34

0.97

3.42

2.29

1.02

3.26

2.22

1.09

19.0

27

3.99

2.63

0.79

3.83

2.55

0.87

3.66

2.48

0.94

3.60

2.45

0.97

3.50

2.41

1.02

3.34

2.33

1.10

22.0

30

4.23

2.53

0.80

4.07

2.46

0.88

3.90

2.39

0.95

3.84

2.37

0.98

3.74

2.33

1.03

3.58

2.26

1.10

24.0

32

4.39

2.45

0.81

4.23

2.39

0.88

4.07

2.33

0.96

4.00

2.30

0.99

3.90

2.27

1.03

3.74

2.21

1.11

Heating
AFR

9.7

INDOOR

OUTDOOR TEMPERATURE (CWB)

EDB

10

10

TC

PI

TC

PI

TC

PI

TC

PI

TC

PI

15.0

2.69

0.91

3.14

0.96

3.60

1.00

4.14

1.06

4.50

1.09

20.0

2.55

0.94

3.01

0.98

3.46

1.03

4.00

1.08

4.36

1.12

22.0

2.50

0.95

2.95

0.99

3.40

1.04

3.94

1.09

4.31

1.13

24.0

2.44

0.96

2.90

1.00

3.35

1.05

3.89

1.10

4.25

1.14

25.0

2.42

0.96

2.87

1.01

3.32

1.05

3.86

1.10

4.22

1.14

27.0

2.36

0.97

2.81

1.02

3.26

1.06

3.81

1.11

4.17

1.15

Symbols:
AFR

: Airflow rate

BF

: Bypass factor

EWB

: Entering wet bulb temp.

(m/min.)
(C)

EDB

: Entering dry bulb temp.

(C)

TC

: Total capacity

(kW)

SHC

: Sensible heat capacity

(kW)

PI

: Power input

(kW)

Notes:
1. Capacities are based on the following conditions.
Corresponding refrigerant piping length : 7.5 m
Level difference : 0 m
2.
shows nominal (rated) capacities and power input.

3D086269

Split Type Air Conditioners FTXS-G Series

19

Capacity Tables

EDVN041323

FTXS50GVMV + RXS50GVMV (50 Hz, 220 - 230 - 240 V / 60 Hz, 220 - 230 V)
Cooling
AFR

14.7

BF

0.18

INDOOR

OUTDOOR TEMPERATURE (CDB)

EWB EDB

20

25

30

32

35

40

TC

SHC

PI

TC

SHC

PI

TC

SHC

PI

TC

SHC

PI

TC

SHC

PI

TC

SHC

PI

14.0

20

5.12

3.74

1.19

4.89

3.62

1.30

4.66

3.51

1.42

4.56

3.46

1.46

4.42

3.39

1.53

4.19

3.28

1.65

16.0

22

5.35

3.68

1.20

5.12

3.57

1.31

4.89

3.46

1.43

4.79

3.41

1.47

4.65

3.35

1.54

4.42

3.24

1.65

18.0

25

5.58

3.84

1.20

5.35

3.74

1.32

5.12

3.64

1.43

5.02

3.60

1.48

4.88

3.53

1.55

4.65

3.44

1.66

19.0

27

5.70

4.04

1.21

5.47

3.94

1.32

5.23

3.84

1.44

5.14

3.81

1.48

5.00

3.75

1.55

4.77

3.65

1.66

22.0

30

6.04

3.90

1.22

5.81

3.81

1.33

5.58

3.72

1.45

5.49

3.69

1.49

5.35

3.63

1.56

5.11

3.55

1.67

24.0

32

6.27

3.79

1.22

6.04

3.71

1.34

5.81

3.63

1.45

5.72

3.60

1.50

5.58

3.55

1.57

5.34

3.47

1.68

Heating
AFR

16.2

INDOOR

OUTDOOR TEMPERATURE (CWB)

EDB

10

10

TC

PI

TC

PI

TC

PI

TC

PI

TC

PI

15.0

3.90

1.35

4.56

1.42

5.21

1.48

6.00

1.56

6.52

1.62

20.0

3.70

1.39

4.36

1.46

5.01

1.52

5.80

1.60

6.32

1.65

22.0

3.62

1.40

4.28

1.47

4.93

1.54

5.72

1.61

6.24

1.67

24.0

3.54

1.42

4.20

1.48

4.85

1.55

5.64

1.63

6.16

1.68

25.0

3.50

1.43

4.16

1.49

4.81

1.56

5.60

1.64

6.12

1.69

27.0

3.42

1.44

4.08

1.51

4.73

1.57

5.52

1.65

6.04

1.70

Symbols:
AFR

: Airflow rate

BF

: Bypass factor

EWB

: Entering wet bulb temp.

(m/min.)
(C)

EDB

: Entering dry bulb temp.

(C)

TC

: Total capacity

(kW)

SHC

: Sensible heat capacity

(kW)

PI

: Power input

(kW)

Notes:
1. Capacities are based on the following conditions.
Corresponding refrigerant piping length : 7.5 m
Level difference : 0 m
2.
shows nominal (rated) capacities and power input.

3D086271

20

Split Type Air Conditioners FTXS-G Series

EDVN041323

Capacity Tables

FTXS60GVMV + RXS60GVMV (50 Hz, 220 - 230 - 240 V / 60 Hz, 220 - 230 V)
Cooling
AFR

16.2

BF

0.28

INDOOR

OUTDOOR TEMPERATURE (CDB)

EWB EDB

20

25

30

32

35

40

TC

SHC

PI

TC

SHC

PI

TC

SHC

PI

TC

SHC

PI

TC

SHC

PI

TC

SHC

PI

14.0

20

5.68

4.00

1.49

5.68

4.00

1.66

5.59

3.95

1.81

5.48

3.89

1.87

5.31

3.80

1.96

5.03

3.66

2.10

16.0

22

6.42

4.18

1.53

6.14

4.03

1.67

5.86

3.89

1.82

5.75

3.84

1.88

5.59

3.75

1.97

5.31

3.62

2.11

18.0

25

6.70

4.32

1.54

6.42

4.19

1.68

6.14

4.06

1.83

6.03

4.00

1.89

5.86

3.93

1.98

5.58

3.80

2.12

19.0

27

6.84

4.51

1.54

6.56

4.38

1.69

6.28

4.25

1.83

6.17

4.20

1.89

6.00

4.12

1.98

5.72

4.00

2.13

22.0

30

7.25

4.33

1.55

6.97

4.21

1.70

6.69

4.10

1.85

6.58

4.06

1.91

6.41

3.99

1.99

6.14

3.88

2.14

24.0

32

7.53

4.20

1.56

7.25

4.09

1.71

6.97

3.99

1.86

6.86

3.95

1.91

6.69

3.89

2.00

6.41

3.79

2.15

Heating
AFR

17.4

INDOOR

OUTDOOR TEMPERATURE (CWB)

EDB

10

10

TC

PI

TC

PI

TC

PI

TC

PI

TC

PI

15.0

4.71

1.73

5.50

1.81

6.29

1.89

7.24

1.99

7.87

2.06

20.0

4.47

1.77

5.26

1.86

6.05

1.94

7.00

2.04

7.63

2.11

22.0

4.37

1.79

5.16

1.87

5.95

1.96

6.90

2.06

7.54

2.13

24.0

4.28

1.81

5.07

1.89

5.86

1.98

6.81

2.08

7.44

2.14

25.0

4.23

1.82

5.02

1.90

5.81

1.99

6.76

2.09

7.39

2.15

27.0

4.13

1.84

4.92

1.92

5.71

2.00

6.66

2.10

7.29

2.17

Symbols:
AFR

: Airflow rate

BF

: Bypass factor

EWB

: Entering wet bulb temp.

(m/min.)
(C)

EDB

: Entering dry bulb temp.

(C)

TC

: Total capacity

(kW)

SHC

: Sensible heat capacity

(kW)

PI

: Power input

(kW)

Notes:
1. Capacities are based on the following conditions.
Corresponding refrigerant piping length : 7.5 m
Level difference : 0 m
2.
shows nominal (rated) capacities and power input.

3D086272

Split Type Air Conditioners FTXS-G Series

21

Capacity Tables

EDVN041323

FTXS71GVMV + RXS71GVMV (50 Hz, 220 - 230 - 240 V / 60 Hz, 220 - 230 V)
Cooling
AFR

17.4

BF

0.27

INDOOR

OUTDOOR TEMPERATURE (CDB)

EWB EDB

20

25

30

32

35

40

TC

SHC

PI

TC

SHC

PI

TC

SHC

PI

TC

SHC

PI

TC

SHC

PI

TC

SHC

PI

14.0

20

6.18

4.36

1.68

6.18

4.36

1.90

6.18

4.36

2.11

6.18

4.36

2.20

6.18

4.36

2.32

5.95

4.23

2.51

16.0

22

7.60

4.87

1.82

7.27

4.69

2.00

6.94

4.52

2.17

6.81

4.45

2.24

6.61

4.35

2.34

6.28

4.19

2.52

18.0

25

7.93

5.02

1.83

7.60

4.85

2.01

7.27

4.69

2.18

7.13

4.63

2.25

6.94

4.53

2.35

6.61

4.38

2.53

19.0

27

8.09

5.21

1.84

7.76

5.06

2.01

7.43

4.90

2.19

7.30

4.84

2.26

7.10

4.75

2.36

6.77

4.60

2.53

22.0

30

8.58

5.00

1.85

8.25

4.86

2.03

7.92

4.72

2.20

7.79

4.67

2.27

7.59

4.59

2.38

7.26

4.45

2.55

24.0

32

8.91

4.85

1.86

8.58

4.72

2.04

8.25

4.59

2.21

8.12

4.54

2.28

7.92

4.46

2.39

7.59

4.34

2.56

Heating
AFR

21.5

INDOOR

OUTDOOR TEMPERATURE (CWB)

EDB

10

10

TC

PI

TC

PI

TC

PI

TC

PI

TC

PI

15.0

5.52

2.13

6.45

2.23

7.37

2.34

8.48

2.46

9.22

2.55

20.0

5.24

2.19

6.16

2.29

7.09

2.40

8.20

2.52

8.94

2.60

22.0

5.12

2.21

6.05

2.31

6.98

2.42

8.09

2.54

8.83

2.63

24.0

5.01

2.23

5.94

2.34

6.86

2.44

7.97

2.57

8.71

2.65

25.0

4.95

2.24

5.88

2.35

6.81

2.45

7.92

2.58

8.66

2.66

27.0

4.84

2.27

5.77

2.37

6.69

2.47

7.80

2.60

8.39

2.67

Symbols:
AFR

: Airflow rate

BF

: Bypass factor

EWB

: Entering wet bulb temp.

(m/min.)
(C)

EDB

: Entering dry bulb temp.

(C)

TC

: Total capacity

(kW)

SHC

: Sensible heat capacity

(kW)

PI

: Power input

(kW)

Notes:
1. Capacities are based on the following conditions.
Corresponding refrigerant piping length : 7.5 m
Level difference : 0 m
2.
shows nominal (rated) capacities and power input.

3D086273

22

Split Type Air Conditioners FTXS-G Series

EDVN041323

7.2

Capacity Tables

Capacity Correction Factor by the Length of Refrigerant Piping (Reference)


The cooling capacity and the heating capacity of the unit have to be corrected in accordance with the length
of refrigerant piping the distance between the indoor unit and the outdoor unit.
< line : cooling capacity>
< --- line : heating capacity>

7.2.1

25/35 Class
R-410A (25/35 Class)

Capacity correction factor

0.9

0.8

Range of the Refrigerant


Additional Charge
5

10

15

20

Piping length (m)


(R19651)

7.2.2

50 Class
R-410A (50 Class)

Capacity correction factor

0.9

0.8
Range of the Refrigerant Additional Charge
5

10

15

20

25

30

Piping length (m)


(R19652)

7.2.3

60/71 Class
R-410A (60/71 Class)

Capacity correction factor

0.9

0.8
Range of the Refrigerant Additional Charge
5

10

15

20

25

30

Piping length (m)


(R19653)

Note:

The graphs show the factor when additional refrigerant of the proper quantity is charged.

Split Type Air Conditioners FTXS-G Series

23

Operation Limit

EDVN041323

8. Operation Limit
RXS25/35GVMV

Heating

Cooling
20

15
50
10
Outdoor temp. (CWB)

46

20

Continuous operation

30

Pull-down period

Continuous operation

Outdoor temp. (CDB)

40

-5

10
-10

10

14

20

23

28 30

Indoor temp. (CWB)

-15
(-15CDB)
Notes:
The graphs are based
on the following conditions.
Equivalent piping length 7.5m
Level difference
0m
Air flow rate
High

10

20

30

Indoor temp. (CDB)


3D078142A

RXS50/60/71GVMV

Cooling

Heating
20

50

18

46
15

10

Continuous operation

20

10

Outdoor temp. (CWB)

Outdoor temp. (CDB)

30

Pull-down period

Continuous operation

40

-5
0
-10
-10

10

14

20

23

Indoor temp. (CWB)

24

28 30

-15
(-15CDB)
Notes:
The graphs are based
on the following conditions.
Equivalent piping length 7.5m
Level difference
0m
Air flow rate
High

10

20

30

Indoor temp. (CDB)

3D078146A

Split Type Air Conditioners FTXS-G Series

EDVN041323

Sound Level

9. Sound Level
9.1

Measuring Location
Indoor Unit

Notes:

Outdoor Unit

1. Operation sound is measured in an anechoic chamber.


2. The data are based on the conditions shown in the table below.
Cooling
Indoor ; 27CDB / 19CWB
Outdoor ; 35CDB / 24CWB

Split Type Air Conditioners FTXS-G Series

Heating
Indoor ; 20CDB
Outdoor ; 7CDB / 6CWB

Piping Length
5m

25

Sound Level

9.2

EDVN041323

Indoor Unit

FTXS25GVMV
COOLING

OCTAVE BAND SOUND PRESSURE LEVEL


dB (0dB=0.0002 bar)

60
NC-60

OPERATING CONDITIONS

NC-50

220-240/220-230v 50/60Hz

POWER SOURCE
40

JIS STANDARD
NC-40

STANDARD EXTERNAL STATIC PRESSURE


50/60Hz 220-240/220-230v (H)

30
NC-30

APPROXIMATE
THRESHOLD HEARING
FOR CONTINUOUS
NOISE
63
125
250
500
1000 2000 4000
OCTAVE BAND CENTER FREQUENCY (Hz)

HEATING
OVER ALL (dB)

NC-70

50/60Hz
50/60Hz
SCALE 220-240/220-230v 220-240/220-230v
(H)
(L)
A
25
37
(B.G.N IS ALREADY RECTIFIED)

50

20

70

OVER ALL (dB)

NC-70

50/60Hz 220-240/220-230v (L)


Cooling

OCTAVE BAND SOUND PRESSURE LEVEL


dB (0dB=0.0002 bar)

70

60
NC-60

50/60Hz
50/60Hz
SCALE 220-240/220-230v 220-240/220-230v
(H)
(L)
A
28
37
(B.G.N IS ALREADY RECTIFIED)

50

OPERATING CONDITIONS

NC-50

POWER SOURCE
40
NC-40

STANDARD EXTERNAL STATIC PRESSURE


50/60Hz 220-240/220-230v (H)

30
NC-30
20

NC-20

APPROXIMATE
THRESHOLD HEARING
FOR CONTINUOUS
NOISE
125
63

50/60Hz 220-240/220-230v (L)


Heating

NC-20

500
250
1000 2000 4000
OCTAVE BAND CENTER FREQUENCY (Hz)

8000

220-240/220-230v 50/60Hz

JIS STANDARD

3D077896A

8000

FTXS35GVMV
COOLING

OCTAVE BAND SOUND PRESSURE LEVEL


dB (0dB=0.0002 bar)

SCALE

60
NC-60

OPERATING CONDITIONS

NC-50

220-240/220-230v 50/60Hz

POWER SOURCE
40

JIS STANDARD
NC-40

STANDARD EXTERNAL STATIC PRESSURE


50/60Hz 220-240/220-230v (H)

30
NC-30

APPROXIMATE
THRESHOLD HEARING
FOR CONTINUOUS
NOISE
63
125
250
500 1000 2000 4000
OCTAVE BAND CENTER FREQUENCY (Hz)

HEATING
OVER ALL (dB)

NC-70

50/60Hz
50/60Hz
220-240/220-230v 220-240/220-230v
(H)
(L)
26
38

(B.G.N IS ALREADY RECTIFIED)

50

20

70

OVER ALL (dB)

NC-70

50/60Hz 220-240/220-230v (L)


Cooling

OCTAVE BAND SOUND PRESSURE LEVEL


dB (0dB=0.0002 bar)

70

SCALE

60
NC-60

50/60Hz
50/60Hz
220-240/220-230v 220-240/220-230v
(H)
(L)
29
38

(B.G.N IS ALREADY RECTIFIED)

50

OPERATING CONDITIONS

NC-50

POWER SOURCE
40
NC-40

STANDARD EXTERNAL STATIC PRESSURE


50/60Hz 220-240/220-230v (H)

30
NC-30
20

NC-20
8000

220-240/220-230v 50/60Hz

JIS STANDARD

APPROXIMATE
THRESHOLD HEARING
FOR CONTINUOUS
NOISE
63
125
250
500
1000 2000 4000
OCTAVE BAND CENTER FREQUENCY (Hz)

50/60Hz 220-240/220-230v (L)


Heating

NC-20

3D077897A

8000

FTXS50GVMV
COOLING

OCTAVE BAND SOUND PRESSURE LEVEL


dB (0dB=0.0002 bar)

SCALE
60
NC-60

44

35

(B.G.N IS ALREADY RECTIFIED)


OPERATING CONDITIONS

NC-50

POWER SOURCE

220-240/220-230V 50/60Hz

JIS STANDARD

40
NC-40

50/60Hz 220-240/220-230v (H)


50/60Hz 220-240/220-230v (L)

30

NC-30

20

63

125

NC-20
250

500

1000

2000

4000

OCTAVE BAND CENTER FREQUENCY (Hz)

8000

Cooling

HEATING
OVER ALL (dB)

NC-70

50/60Hz
50/60Hz
220-240/220-230v 220-240/220-230v
(H)
(L)

50

APPROXIMATE
THRESHOLD HEARING
FOR CONTINUOUS
NOISE

26

70

OVER ALL (dB)

NC-70

SCALE
OCTAVE BAND SOUND PRESSURE LEVEL
dB (0dB=0.0002 bar)

70

60
NC-60

50/60Hz
50/60Hz
220-240/220-230v 220-240/220-230v
(H)
(L)

42

33

(B.G.N IS ALREADY RECTIFIED)


50
OPERATING CONDITIONS

NC-50

POWER SOURCE

220-240/220-230V 50/60Hz

JIS STANDARD

40
NC-40

50/60Hz 220-240/220-230v (H)


50/60Hz 220-240/220-230v (L)

30
NC-30

Heating

20

APPROXIMATE
THRESHOLD HEARING
FOR CONTINUOUS
NOISE
63

125

NC-20
250

500

1000

2000

4000

8000

3D077900A

OCTAVE BAND CENTER FREQUENCY (Hz)

Split Type Air Conditioners FTXS-G Series

EDVN041323

Sound Level

FTXS60GVMV
COOLING

OCTAVE BAND SOUND PRESSURE LEVEL


dB (0dB=0.0002 bar)

60
NC-60

50/60Hz
50/60Hz
SCALE 220-240/220-230v 220-240/220-230v
(H)
(L)
A
36
45
(B.G.N IS ALREADY RECTIFIED)

50

OPERATING CONDITIONS

NC-50

POWER SOURCE
40

220-240/220-230v 50/60Hz

JIS STANDARD
NC-40

50/60Hz 220-240/220-230v (H)


50/60Hz 220-240/220-230v (L)

30
Cooling
NC-30
20

APPROXIMATE
THRESHOLD HEARING
FOR CONTINUOUS
NOISE
125
250
500
1000 2000 4000
63
OCTAVE BAND CENTER FREQUENCY (Hz)

70

OVER ALL (dB)

NC-70

HEATING
OVER ALL (dB)

NC-70
OCTAVE BAND SOUND PRESSURE LEVEL
dB (0dB=0.0002 bar)

70

60
NC-60

50/60Hz
50/60Hz
SCALE 220-240/220-230v 220-240/220-230v
(H)
(L)
A
35
44
(B.G.N IS ALREADY RECTIFIED)

50
NC-50

OPERATING CONDITIONS
POWER SOURCE

40

220-240/220-230v 50/60Hz

JIS STANDARD
NC-40

50/60Hz 220-240/220-230v (H)


50/60Hz 220-240/220-230v (L)

30
Heating
NC-30
20

NC-20

APPROXIMATE
THRESHOLD HEARING
FOR CONTINUOUS
NOISE
125
63

NC-20
250

500

1000 2000 4000


OCTAVE BAND CENTER FREQUENCY (Hz)

8000

3D077939A

8000

FTXS71GVMV
COOLING

OCTAVE BAND SOUND PRESSURE LEVEL


dB (0dB=0.0002 bar)

60
NC-60

50/60Hz
50/60Hz
SCALE 220-240/220-230v 220-240/220-230v
(H)
(L)
A
37
46
(B.G.N IS ALREADY RECTIFIED)

50

OPERATING CONDITIONS

NC-50

POWER SOURCE
40
NC-40

50/60Hz 220-240/220-230v (H)


50/60Hz 220-240/220-230v (L)

30

20

220-240/220-230v 50/60Hz

JIS STANDARD

NC-30

APPROXIMATE
THRESHOLD HEARING
FOR CONTINUOUS
NOISE
63
125
250
500
1000 2000 4000
OCTAVE BAND CENTER FREQUENCY (Hz)

70

OVER ALL (dB)

NC-70

Cooling

NC-20
8000

Split Type Air Conditioners FTXS-G Series

HEATING
OVER ALL (dB)

NC-70
OCTAVE BAND SOUND PRESSURE LEVEL
dB (0dB=0.0002 bar)

70

60
NC-60

50/60Hz
50/60Hz
SCALE 220-240/220-230v 220-240/220-230v
(H)
(L)
A
37
46
(B.G.N IS ALREADY RECTIFIED)

50
NC-50

OPERATING CONDITIONS
POWER SOURCE

40
NC-40

50/60Hz 220-240/220-230v (H)


50/60Hz 220-240/220-230v (L)

30
NC-30
20

220-240/220-230v 50/60Hz

JIS STANDARD

APPROXIMATE
THRESHOLD HEARING
FOR CONTINUOUS
NOISE
125
63

Heating

NC-20
250

500

1000 2000 4000


OCTAVE BAND CENTER FREQUENCY (Hz)

8000

3D077904A

27

Sound Level

9.3

EDVN041323

Outdoor Unit

RXS25GVMV
COOLING

OCTAVE BAND SOUND PRESSURE LEVEL


dB (0dB=0.0002 bar)

SCALE

60
NC-60

50/60Hz
220-240/220-230v

46

(B.G.N IS ALREADY RECTIFIED)

50

OPERATING CONDITIONS

NC-50

POWER SOURCE
40

220-240/220-230v 50/60Hz

JIS STANDARD
NC-40

50/60Hz 220-240/220-230v
Cooling

30
NC-30
20

APPROXIMATE
THRESHOLD HEARING
FOR CONTINUOUS
NOISE
63
125
250
500
1000 2000 4000
OCTAVE BAND CENTER FREQUENCY (Hz)

70

OVER ALL (dB)

NC-70

HEATING
OVER ALL (dB)

NC-70
OCTAVE BAND SOUND PRESSURE LEVEL
dB (0dB=0.0002 bar)

70

60
NC-60

SCALE

50/60Hz
220-240/220-230v

47

(B.G.N IS ALREADY RECTIFIED)

50

OPERATING CONDITIONS

NC-50

POWER SOURCE
40

220-240/220-230v 50/60Hz

JIS STANDARD
NC-40

50/60Hz 220-240/220-230v
Heating

30
NC-30
20

NC-20

APPROXIMATE
THRESHOLD HEARING
FOR CONTINUOUS
NOISE
125
63

NC-20
250

500

1000 2000 4000


OCTAVE BAND CENTER FREQUENCY (Hz)

8000

3D078008A

8000

RXS35GVMV
COOLING

OCTAVE BAND SOUND PRESSURE LEVEL


dB (0dB=0.0002 bar)

60
NC-60

SCALE

50/60Hz
220-240/220-230v

47

(B.G.N IS ALREADY RECTIFIED)

50

OPERATING CONDITIONS

NC-50

POWER SOURCE
40

220-240/220-230v 50/60Hz

JIS STANDARD
NC-40

50/60Hz 220-240/220-230v
Cooling

30
NC-30
20

APPROXIMATE
THRESHOLD HEARING
FOR CONTINUOUS
NOISE
63
125
250
500
1000 2000 4000
OCTAVE BAND CENTER FREQUENCY (Hz)

70

OVER ALL (dB)

NC-70

HEATING
OVER ALL (dB)

NC-70
OCTAVE BAND SOUND PRESSURE LEVEL
dB (0dB=0.0002 bar)

70

60
NC-60

SCALE

50/60Hz
220-240/220-230v

48

(B.G.N IS ALREADY RECTIFIED)

50

OPERATING CONDITIONS

NC-50

POWER SOURCE
40

220-240/220-230v 50/60Hz

JIS STANDARD
NC-40

50/60Hz 220-240/220-230v
Heating

30
NC-30
20

NC-20

APPROXIMATE
THRESHOLD HEARING
FOR CONTINUOUS
NOISE
125
63

NC-20
250

500

1000 2000 4000


OCTAVE BAND CENTER FREQUENCY (Hz)

8000

3D078009A

8000

RXS50GVMV
COOLING

OCTAVE BAND SOUND PRESSURE LEVEL


dB (0dB=0.0002 bar)

28

60
NC-60

SCALE

50/60Hz
220-240/220-230v

47

(B.G.N IS ALREADY RECTIFIED)

50
NC-50

OPERATING CONDITIONS
POWER SOURCE

40
NC-40

50/60Hz 220-240/220-230v
Cooling

NC-30
20

220-240/220-230v 50/60Hz

JIS STANDARD

30

APPROXIMATE
THRESHOLD HEARING
FOR CONTINUOUS
NOISE
63
125
250
500
1000 2000 4000
OCTAVE BAND CENTER FREQUENCY (Hz)

NC-20
8000

70

OVER ALL (dB)

NC-70

HEATING
OVER ALL (dB)

NC-70
OCTAVE BAND SOUND PRESSURE LEVEL
dB (0dB=0.0002 bar)

70

60
NC-60

SCALE

50/60Hz
220-240/220-230v

48

(B.G.N IS ALREADY RECTIFIED)

50
NC-50

OPERATING CONDITIONS
POWER SOURCE

40

220-240/220-230v 50/60Hz

JIS STANDARD
NC-40

50/60Hz 220-240/220-230v
Heating

30
NC-30
20

APPROXIMATE
THRESHOLD HEARING
FOR CONTINUOUS
NOISE
125
63

NC-20

500
250
1000 2000 4000
OCTAVE BAND CENTER FREQUENCY (Hz)

8000

3D078015A

Split Type Air Conditioners FTXS-G Series

EDVN041323

Sound Level

RXS60GVMV
COOLING

OCTAVE BAND SOUND PRESSURE LEVEL


dB (0dB=0.0002 bar)

SCALE

60
NC-60

50/60Hz
220-240/220-230v

49

(B.G.N IS ALREADY RECTIFIED)

50

OPERATING CONDITIONS

NC-50

POWER SOURCE
40

220-240/220-230v 50/60Hz

JIS STANDARD

NC-40

50/60Hz 220-240/220-230v
Cooling
30
NC-30
20

APPROXIMATE
THRESHOLD HEARING
FOR CONTINUOUS
NOISE
63
125
250
500
1000 2000 4000
OCTAVE BAND CENTER FREQUENCY (Hz)

70

OVER ALL (dB)

NC-70

HEATING
OVER ALL (dB)

NC-70
OCTAVE BAND SOUND PRESSURE LEVEL
dB (0dB=0.0002 bar)

70

60
NC-60

SCALE

50/60Hz
220-240/220-230v

49

(B.G.N IS ALREADY RECTIFIED)

50

OPERATING CONDITIONS

NC-50

POWER SOURCE
40

220-240/220-230v 50/60Hz

JIS STANDARD
NC-40

50/60Hz 220-240/220-230v
Heating

30
NC-30
20

NC-20

APPROXIMATE
THRESHOLD HEARING
FOR CONTINUOUS
NOISE
125
63

NC-20
250

500

1000 2000 4000


OCTAVE BAND CENTER FREQUENCY (Hz)

8000

3D078016A

8000

RXS71GVMV
COOLING

OCTAVE BAND SOUND PRESSURE LEVEL


dB (0dB=0.0002 bar)

60

SCALE

50/60Hz
220-240/220-230v

52

NC-60

(B.G.N IS ALREADY RECTIFIED)

50

OPERATING CONDITIONS

NC-50

POWER SOURCE

220-240/220-230v 50/60Hz

JIS STANDARD

40
NC-40
Cooling
30
NC-30
20

APPROXIMATE
THRESHOLD HEARING
FOR CONTINUOUS
NOISE
63
125
250
500
1000 2000 4000
OCTAVE BAND CENTER FREQUENCY (Hz)

70

OVER ALL (dB)

NC-70

NC-20
8000

Split Type Air Conditioners FTXS-G Series

HEATING
OVER ALL (dB)

NC-70
OCTAVE BAND SOUND PRESSURE LEVEL
dB (0dB=0.0002 bar)

70

60
NC-60

SCALE

50/60Hz
220-240/220-230v

52

(B.G.N IS ALREADY RECTIFIED)

50
NC-50

OPERATING CONDITIONS
POWER SOURCE

220-240/220-230v 50/60Hz

JIS STANDARD

40
NC-40
Heating
30
NC-30
20

APPROXIMATE
THRESHOLD HEARING
FOR CONTINUOUS
NOISE
125
63

NC-20
250

500

1000 2000 4000


OCTAVE BAND CENTER FREQUENCY (Hz)

8000

3D078017A

29

Electric Characteristics

EDVN041323

10. Electric Characteristics


Indoor Unit

Outdoor Unit

Power Supply
Hz - Volts

Voltage Range

Compressor
MCA

MFA

RHz

50 - 220
50 - 230
FTXS25GVMV

RXS25GVMV

60 - 230

Max. 50 Hz, 264 V


Min. 50 Hz, 198 V

FTXS35GVMV

RXS35GVMV

10

48.5

60 - 230

FTXS50GVMV

RXS50GVMV

60 - 230

FTXS60GVMV

RXS60GVMV

9.75

10

75

60 - 230

FTXS71GVMV

RXS71GVMV

60 - 220

40

0.14

4.0

50

0.22

40

0.14

53

0.32

43

0.17

53

0.39

43

0.18

66

0.40

43

0.19

4.2

Max. 50 Hz, 264 V


Min. 50 Hz, 198 V

6.4
19.75

20

67

6.1
6.7

Max. 60 Hz, 253 V


Min. 60 Hz, 198 V

6.4
8.7

Max. 50 Hz, 264 V


Min. 50 Hz, 198 V

8.3
19.75

20

84

7.9
8.7

Max. 60 Hz, 253 V


Min. 60 Hz, 198 V

8.3
10.3

Max. 50 Hz, 264 V


Min. 50 Hz, 198 V

50 - 240
60 - 230

0.22

6.7

50 - 220
50 - 230

50

4.4

Max. 60 Hz, 253 V


Min. 60 Hz, 198 V

50 - 240
60 - 220

3.2

4.2

50 - 220
50 - 230

FLA

3.3

Max. 50 Hz, 264 V


Min. 50 Hz, 198 V

50 - 240
60 - 220

4.4

50 - 220
50 - 230

FLA

3.5

Max. 60 Hz, 253 V


Min. 60 Hz, 198 V

50 - 240
60 - 220

3.3
9.75

50 - 220
50 - 230

IFM

3.5

50 - 240
60 - 220

RLA

OFM

9.9
19.75

20

56

9.4
10.3

Max. 60 Hz, 253 V


Min. 60 Hz, 198 V

9.9

Symbols:

Notes:

MCA

: Min. circuit amps (A)

MFA

: Max. fuse amps (A)

1. RLA is based on the following conditions.


Indoor temp. 27CDB / 19CWB
Outdoor temp. 35CDB.
2. Maximum allowable voltage variation between phases is 2%.
3. Select wire size based on the larger value of MCA.
4. Instead of fuse, use circuit breaker.
5. Be sure to install an earth leak detector. (One that can handle
higher harmonics.)
(This unit uses an inverter, which means that an earth leak
detector capable handling high harmonics must be used in order
to prevent malfunctioning of the earth leak detector.)

RHz

: Rated operating frequency (Hz)

RLA

: Rated load amps (A)

OFM

: Outdoor fan motor

IFM

: Indoor fan motor

: Fan motor rated output (W)

FLA

: Full load amps (A)

3D086071
3D086072
3D086073
3D086074

30

Split Type Air Conditioners FTXS-G Series

EDVN041323

Installation Manual

11. Installation Manual


11.1 Safety Precautions

Split Type Air Conditioners FTXS-G Series

31

Installation Manual

EDVN041323

11.2 25/35 Class


11.2.1 Indoor Unit

32

Split Type Air Conditioners FTXS-G Series

EDVN041323

Split Type Air Conditioners FTXS-G Series

Installation Manual

33

Installation Manual

34

EDVN041323

Split Type Air Conditioners FTXS-G Series

EDVN041323

Split Type Air Conditioners FTXS-G Series

Installation Manual

35

Installation Manual

36

EDVN041323

Split Type Air Conditioners FTXS-G Series

EDVN041323

Split Type Air Conditioners FTXS-G Series

Installation Manual

37

Installation Manual

EDVN041323

3PN14832-8E

38

Split Type Air Conditioners FTXS-G Series

EDVN041323

Installation Manual

11.2.2 Outdoor Unit

Split Type Air Conditioners FTXS-G Series

39

Installation Manual

40

EDVN041323

Split Type Air Conditioners FTXS-G Series

EDVN041323

Split Type Air Conditioners FTXS-G Series

Installation Manual

41

Installation Manual

42

EDVN041323

Split Type Air Conditioners FTXS-G Series

EDVN041323

Split Type Air Conditioners FTXS-G Series

Installation Manual

43

Installation Manual

44

EDVN041323

Split Type Air Conditioners FTXS-G Series

EDVN041323

Installation Manual

3PN14832-9E

Split Type Air Conditioners FTXS-G Series

45

Installation Manual

EDVN041323

11.3 50/60 Class


11.3.1 Indoor Unit

46

Split Type Air Conditioners FTXS-G Series

EDVN041323

Split Type Air Conditioners FTXS-G Series

Installation Manual

47

Installation Manual

48

EDVN041323

Split Type Air Conditioners FTXS-G Series

EDVN041323

Split Type Air Conditioners FTXS-G Series

Installation Manual

49

Installation Manual

50

EDVN041323

Split Type Air Conditioners FTXS-G Series

EDVN041323

Split Type Air Conditioners FTXS-G Series

Installation Manual

51

Installation Manual

EDVN041323

3PN14832-10E

52

Split Type Air Conditioners FTXS-G Series

EDVN041323

Installation Manual

11.3.2 Outdoor Unit

Split Type Air Conditioners FTXS-G Series

53

Installation Manual

54

EDVN041323

Split Type Air Conditioners FTXS-G Series

EDVN041323

Split Type Air Conditioners FTXS-G Series

Installation Manual

55

Installation Manual

56

EDVN041323

Split Type Air Conditioners FTXS-G Series

EDVN041323

Split Type Air Conditioners FTXS-G Series

Installation Manual

57

Installation Manual

58

EDVN041323

Split Type Air Conditioners FTXS-G Series

EDVN041323

Installation Manual

3PN14832-11E

Split Type Air Conditioners FTXS-G Series

59

Installation Manual

EDVN041323

11.4 71 Class
11.4.1 Indoor Unit

60

Split Type Air Conditioners FTXS-G Series

EDVN041323

Split Type Air Conditioners FTXS-G Series

Installation Manual

61

Installation Manual

62

EDVN041323

Split Type Air Conditioners FTXS-G Series

EDVN041323

Split Type Air Conditioners FTXS-G Series

Installation Manual

63

Installation Manual

64

EDVN041323

Split Type Air Conditioners FTXS-G Series

EDVN041323

Split Type Air Conditioners FTXS-G Series

Installation Manual

65

Installation Manual

EDVN041323

3PN14832-12E

66

Split Type Air Conditioners FTXS-G Series

EDVN041323

Installation Manual

11.4.2 Outdoor Unit

Split Type Air Conditioners FTXS-G Series

67

Installation Manual

68

EDVN041323

Split Type Air Conditioners FTXS-G Series

EDVN041323

Split Type Air Conditioners FTXS-G Series

Installation Manual

69

Installation Manual

70

EDVN041323

Split Type Air Conditioners FTXS-G Series

EDVN041323

Split Type Air Conditioners FTXS-G Series

Installation Manual

71

Installation Manual

72

EDVN041323

Split Type Air Conditioners FTXS-G Series

EDVN041323

Installation Manual

3PN14832-13E

Split Type Air Conditioners FTXS-G Series

73

Operation Manual

EDVN041323

12. Operation Manual


12.1 Safety Precautions

74

Split Type Air Conditioners FTXS-G Series

EDVN041323

Split Type Air Conditioners FTXS-G Series

Operation Manual

75

Operation Manual

76

EDVN041323

Split Type Air Conditioners FTXS-G Series

EDVN041323

Operation Manual

12.2 25/35 Class

Split Type Air Conditioners FTXS-G Series

77

Operation Manual

78

EDVN041323

Split Type Air Conditioners FTXS-G Series

EDVN041323

Split Type Air Conditioners FTXS-G Series

Operation Manual

79

Operation Manual

80

EDVN041323

Split Type Air Conditioners FTXS-G Series

EDVN041323

Split Type Air Conditioners FTXS-G Series

Operation Manual

81

Operation Manual

82

EDVN041323

Split Type Air Conditioners FTXS-G Series

EDVN041323

Split Type Air Conditioners FTXS-G Series

Operation Manual

83

Operation Manual

84

EDVN041323

Split Type Air Conditioners FTXS-G Series

EDVN041323

Split Type Air Conditioners FTXS-G Series

Operation Manual

85

Operation Manual

86

EDVN041323

Split Type Air Conditioners FTXS-G Series

EDVN041323

Split Type Air Conditioners FTXS-G Series

Operation Manual

87

Operation Manual

88

EDVN041323

Split Type Air Conditioners FTXS-G Series

EDVN041323

Split Type Air Conditioners FTXS-G Series

Operation Manual

89

Operation Manual

90

EDVN041323

Split Type Air Conditioners FTXS-G Series

EDVN041323

Split Type Air Conditioners FTXS-G Series

Operation Manual

91

Operation Manual

92

EDVN041323

Split Type Air Conditioners FTXS-G Series

EDVN041323

Split Type Air Conditioners FTXS-G Series

Operation Manual

93

Operation Manual

94

EDVN041323

Split Type Air Conditioners FTXS-G Series

EDVN041323

Split Type Air Conditioners FTXS-G Series

Operation Manual

95

Operation Manual

96

EDVN041323

Split Type Air Conditioners FTXS-G Series

EDVN041323

Split Type Air Conditioners FTXS-G Series

Operation Manual

97

Operation Manual

98

EDVN041323

Split Type Air Conditioners FTXS-G Series

EDVN041323

Split Type Air Conditioners FTXS-G Series

Operation Manual

99

Operation Manual

EDVN041323

3PN14831-3G

100

Split Type Air Conditioners FTXS-G Series

EDVN041323

Operation Manual

12.3 50/60 Class

Split Type Air Conditioners FTXS-G Series

101

Operation Manual

102

EDVN041323

Split Type Air Conditioners FTXS-G Series

EDVN041323

Split Type Air Conditioners FTXS-G Series

Operation Manual

103

Operation Manual

104

EDVN041323

Split Type Air Conditioners FTXS-G Series

EDVN041323

Split Type Air Conditioners FTXS-G Series

Operation Manual

105

Operation Manual

106

EDVN041323

Split Type Air Conditioners FTXS-G Series

EDVN041323

Split Type Air Conditioners FTXS-G Series

Operation Manual

107

Operation Manual

108

EDVN041323

Split Type Air Conditioners FTXS-G Series

EDVN041323

Split Type Air Conditioners FTXS-G Series

Operation Manual

109

Operation Manual

110

EDVN041323

Split Type Air Conditioners FTXS-G Series

EDVN041323

Split Type Air Conditioners FTXS-G Series

Operation Manual

111

Operation Manual

112

EDVN041323

Split Type Air Conditioners FTXS-G Series

EDVN041323

Split Type Air Conditioners FTXS-G Series

Operation Manual

113

Operation Manual

114

EDVN041323

Split Type Air Conditioners FTXS-G Series

EDVN041323

Split Type Air Conditioners FTXS-G Series

Operation Manual

115

Operation Manual

116

EDVN041323

Split Type Air Conditioners FTXS-G Series

EDVN041323

Split Type Air Conditioners FTXS-G Series

Operation Manual

117

Operation Manual

118

EDVN041323

Split Type Air Conditioners FTXS-G Series

EDVN041323

Split Type Air Conditioners FTXS-G Series

Operation Manual

119

Operation Manual

120

EDVN041323

Split Type Air Conditioners FTXS-G Series

EDVN041323

Split Type Air Conditioners FTXS-G Series

Operation Manual

121

Operation Manual

122

EDVN041323

Split Type Air Conditioners FTXS-G Series

EDVN041323

Split Type Air Conditioners FTXS-G Series

Operation Manual

123

Operation Manual

EDVN041323

3PN14831-4G

124

Split Type Air Conditioners FTXS-G Series

EDVN041323

Operation Manual

12.4 71 Class

Split Type Air Conditioners FTXS-G Series

125

Operation Manual

126

EDVN041323

Split Type Air Conditioners FTXS-G Series

EDVN041323

Split Type Air Conditioners FTXS-G Series

Operation Manual

127

Operation Manual

128

EDVN041323

Split Type Air Conditioners FTXS-G Series

EDVN041323

Split Type Air Conditioners FTXS-G Series

Operation Manual

129

Operation Manual

130

EDVN041323

Split Type Air Conditioners FTXS-G Series

EDVN041323

Split Type Air Conditioners FTXS-G Series

Operation Manual

131

Operation Manual

132

EDVN041323

Split Type Air Conditioners FTXS-G Series

EDVN041323

Split Type Air Conditioners FTXS-G Series

Operation Manual

133

Operation Manual

134

EDVN041323

Split Type Air Conditioners FTXS-G Series

EDVN041323

Split Type Air Conditioners FTXS-G Series

Operation Manual

135

Operation Manual

136

EDVN041323

Split Type Air Conditioners FTXS-G Series

EDVN041323

Split Type Air Conditioners FTXS-G Series

Operation Manual

137

Operation Manual

138

EDVN041323

Split Type Air Conditioners FTXS-G Series

EDVN041323

Split Type Air Conditioners FTXS-G Series

Operation Manual

139

Operation Manual

140

EDVN041323

Split Type Air Conditioners FTXS-G Series

EDVN041323

Split Type Air Conditioners FTXS-G Series

Operation Manual

141

Operation Manual

142

EDVN041323

Split Type Air Conditioners FTXS-G Series

EDVN041323

Split Type Air Conditioners FTXS-G Series

Operation Manual

143

Operation Manual

144

EDVN041323

Split Type Air Conditioners FTXS-G Series

EDVN041323

Split Type Air Conditioners FTXS-G Series

Operation Manual

145

Operation Manual

146

EDVN041323

Split Type Air Conditioners FTXS-G Series

EDVN041323

Split Type Air Conditioners FTXS-G Series

Operation Manual

147

Operation Manual

148

EDVN041323

Split Type Air Conditioners FTXS-G Series

EDVN041323

Split Type Air Conditioners FTXS-G Series

Operation Manual

149

Operation Manual

EDVN041323

3PN14831-5G

150

Split Type Air Conditioners FTXS-G Series

EDVN041323

Optional Accessories

13. Optional Accessories


13.1 Option List
13.1.1 Indoor Unit
Option Name

Note:

Air-Purifying Filter with Photocatalytic Deodorising Function


(without Frame)

Remote Controller Loss Prevention with Chain

25/35 Class

50/60/71 Class

KAF970A46

KAF971B42

KKF917A4

Standard accessory

13.1.2 Outdoor Unit


Option Name
1

Air Direction Adjustment Grille

Drain Plug

Split Type Air Conditioners FTXS-G Series

25/35 Class

50/60 Class

KPW937A4
KKP937A4

71 Class

KPW945A4
KKP945A4

151

Optional Accessories

EDVN041323

13.2 <KPW937A4> Air Direction Adjustment Grille


Q Before Installation
Checking the parts

Check the following parts


Name

Louver

Installation manual

Shape

Quantity

With 4 screws
1piece

1piece

Q Installation Procedure
Selection of Installation Location
Use when installing in a location that meets the following conditions.
zWhen installing near the border to a neighbor's house
zIf exhaust blows directly on passers-by because outdoor unit is installed facing a road.
zChanging the fan direction of the outdoor unit to prevent it blowing directly on shrubbery, etc.

Installation of Louver
zInstallation is possible in the four directions:
upward, downward, rightward, and leftward.
zThe installation screws are attached to the louver.
zFirst temporarily attach the louver with 4 screws,
then check that the angle is correct, and finally
tighten the screws fully.

Prepared hole
pitch 435mm
Fan partition
Part A
(see figure below)
Prepared hole
pitch 435mm
Fan partition

CAUTION
1.Install so that a short circuit is prevented.
2.For the use in snowy regions, avoid installation
with the air outlet facing upward. Install so that
the air outlet faces leftward, rightward, or downward.
Snow accumulates in the air outlet of the outdoor
unit, causing malfunction of the main body of the
outdoor unit.
3.Be advised that if the fan direction is up,
dead leaves and other foreign matter
easily accumulates in the exhaust vent.

The prepared hole is in between the grating


of the grille. Part A (prepared hole) cross
section (the shape of either a or b)

a) Grille grating

Prepared hole

b) Grille grating

Prepared hole

4P104499-1A

152

Split Type Air Conditioners FTXS-G Series

EDVN041323

Optional Accessories

13.3 <KPW945A4> Air Direction Adjustment Grille


Before installation
Check the following parts

Name

Louver

Truss tapping screw

Installation manual

1piece

M44screws(max.7.5kW class)
M54screws(8.0/9.0kW class)

1piece

Shape

Quantity

Installation Procedure
Selection of Installation Location
Use when installing in a location that meets the following conditions.
O When installing near the border to a neighbor's house
O If exhaust blows directly on passers-by because outdoor unit is installed facing a road.
O If exhaust blows directly on vegetation

Space Needed for Installation


O

A minimum of 100mm is needed


between the back of the outdoor
unit and any obstructions
(walls, etc.)
m

t
ore

han

100

Installation of Louvers
Caution
Attach the louvers overlapping the standard grille.
Installing the louvers without the grille would allow hands to enter the fan area,
which is dangerous, so be sure to install the standard grille.
When pointing up

When pointing down

(1) Remove the 4 attachment screws from


the standard grille.

(1) Remove the 4 attachment screws from


the standard grille.

(2) Install the louver pointed up.

(2) Install the louver pointed down.

O
O

Overlap the standard grille and


screw both in together.
The attachment screws
are in the louvers.

(3) Installation complete

Overlap the standard grille and


screw both in together.
O The attachment screws
are in the louvers.
O

(3) Installation complete

3P089958-2C

Split Type Air Conditioners FTXS-G Series

153

Optional Accessories

EDVN041323

13.4 <KKP945A4> Drain Plug

3P089958-1B

154

Split Type Air Conditioners FTXS-G Series

EDVN041323

Warning

ENGINEERING DATA

Ask a qualified installer or contractor to install this product. Do not try to install the product yourself.
Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.

EDVN041323

Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or
contractor to install those parts and accessories. Use of unauthorised parts and accessories or
improper installation of parts and accessories can result in water or refrigerant leakage, electrical
shock, fire or explosion.
Read the User's Manual carefully before using this product. The User's Manual provides important
safety instructions and warnings. Be sure to follow these instructions and warnings.

SPLIT

If you have any enquiries, please contact your local importer, distributor and/or retailer.

FTXS-G Series

Cautions on product corrosion


1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.
2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install
the outdoor unit close to the sea shore, contact your local distributor.

- Heat Pump FTXS-G Series

Specifications, designs and other content appearing in this brochure are current as of December 2013 but subject to change without notice.
c All rights reserved

AK