You are on page 1of 1

Burn Drive Motor Does Not Park

Normal Operation Sequence

10 - Plug the Stove In 21 Push the ON Button


11 LED's indicate P.O.S.T.
12 Burn Drive cycles three (3) times Burn Drive Motor cycles 3
13 Exhaust Fan Runs for 30 min then OFF 24 times and stops on switch

20 - Startup Mode Does Brake Arm


21 Push ON Button & set Heat Level Assembly move Free up Brake Arm
22 #1 LED on NO freely? NO Assembly
23 Number of LED's show Set Heat Level
24 Burn Drive cycles three (3) times
25 Feed Wheel Begins Feeding Fuel
26 After 1½ minutes, Air pump comes ON
27 After 15 seconds, the Igniters turn ON YES YES
28 Within 5 minutes, Smoke and than Flame Does the Brake
29 Igniters turn OFF after Flame is established YES Armature engage
30 After 15 seconds the Air Pump goes OFF into the Slot on the
31 Stove Ramps to Heat Level 4 wheel on the Motor
shaft?
32 After 20 minute Startup Period, stove ramps
up or down to User Set Heat Level
NO

40 - Normal Run mode


41 Stove runs at User SET HEAT Level Inspect
Limit Adjust if possible
42 Ash Dump per Heat Level Switch for
43 Stove ramps to Heat Level 4 during the Ash sticking
Dump process
44 Stove runs until User turns the Stove OFF Not Possible

YES

50 - Normal Shut Down Mode

51 Push the OFF Button


52 Feeder Wheel Stops feeding Fuel
53 1st 10 minutes Exhaust Fan Increases speed
54 Next 20 minutes Exh. Fan runs at 50% speed
55 After 30 min. total, Ash Dump, Stove is OFF 41, 42, 43, 44

Run Stove Repair or Replace Replace the Burn Drive Motor as per
Limit Switch as Kit instructions
necessary

H:\Tech Support\Training\SMTSG - Burn Drive Motor Does Not Park.doc