13. JAM CODE

TROUBLESHOOTING
13. JAM CODE
13.1 Jam code list
Classification Tray 1 Jam code During operation J11-01 The paper feed sensor /1 (PS7) does not turn ON within a specified period of time after the paper feed clutch /1 (CL4) turns ON. The pre-registration sensor /1 (PS17) does not turn ON within a specified period of time after the paper feed clutch /1 (CL4) turns ON. J11-03 The vertical conveyance sensor /1 (PS19) does not turn ON within a specified period of time after the pre-registration sensor /1 (PS17) turns ON. J11-04 When the trailing edge of paper is pass- After completion ing through the vertical conveyance sensor /1 (PS19), the pre-registration sensor /1 (PS17) is turned ON by the succeeding paper. When idling J11-05 The vertical conveyance sensor /1 (PS19) turns ON while in idling. of the exit of the preceding paper, the main body stops operations. Open the main body vertical conveyance door and remove jammed paper if any. The pre-registration sensor /1 (PS17) turns ON while in idling. During operation Tray 2 J12-01 The paper feed sensor /2 (PS13) does not turn ON within a specified period of time after the paper feed clutch /2 (CL6) turns ON. The pre-registration sensor /2 (PS18) does not turn ON within a specified period of time after the paper feedclutch /2 (CL6) turns ON. J12-03 The vertical conveyance sensor /3 (PS21) does not turn ON within a specified period of time after the pre-registration sensor /2 (PS18) turns ON. If there is a sheet of paper being printed when a jam occurs, the main body completes the paper exit before stopping operations. Open tray /2 and the main body vertical conveyance door, and remove jammed paper if any. Pull out tray /1 and remove jammed paper if any. Pull out tray /2 and remove jammed paper if any. Cause Resulting operation If there is a sheet of paper being printed when a jam occurs, the main body completes the paper exit before stopping operations. Open tray /1 and the main body vertical conveyance door, and remove jammed paper if any. Pull out tray /1 and remove jammed paper if any. Correction

J11-02

J11-06

J12-02

533

bizhub PRO 1050/1050P 1050e/1050eP

13. JAM CODE

Field Service Ver3.0 Nov.2006 Jam code During operation Cause When the trailing edge of paper is passing through the vertical conveyance sensor /3 (PS21), the pre-registration sensor /2 (PS18) is turned ON by the succeeding paper. The vertical conveyance sensor /3 (PS21) turns ON while in idling. Resulting operation After completion of the exit of the preceding paper, the main body stops operations. Open tray /2 and the main body vertical conveyance door, and remove jammed paper if any. Open the main body vertical conveyance door and remove jammed paper if any. The pre-registration sensor /2 (PS18) turns ON while in idling. During operation Pull out tray /2 and remove jammed paper if any. If there is a sheet of paper being printed when a jam occurs, the main body completes the paper exit before stopping operations. Open tray /3, the PF front door and the vertical conveyance door / Up, and remove jammed paper if any. Pull out tray /3 and remove jammed paper if any. Correction

bizhub PRO 1050/1050P /1050e/1050eP

Classification Tray 2

J12-04

J12-06

Tray 3 (PF)

J13-01

When idling

J12-05

The paper feed sensor /1 (PS72) does not turn ON within a specified period of time after the pick-up clutch /1 (CL6) turns ON. The pre-registration sensor /1 (PS89) does not turn ON within a specified period of time after the pick-up clutch / 1 (CL6) turns ON.

J13-02

J13-03

The vertical conveyance sensor /1 (PS90) does not turn ON within a specified period of time after the pre-registration sensor /1 (PS89) turns ON.

J13-04

When the trailing edge of paper is pass- After completion ing through the vertical conveyance sensor /1 (PS90), the pre-registration sensor /1 (PS89) is turned ON by the succeeding paper. When idling of the exit of the preceding paper, the main body stops operations. Open the PF front door and the vertical conveyance door /Up and remove jammed paper if any. The pre-registration sensor /1 (PS89) turns ON while in idling. Pull out tray /3 and remove jammed paper if any.

J13-05

The vertical conveyance sensor /1 (PS90) turns ON while in idling.

J13-06

534

Field Service Ver3.0 Nov.2006 Classification Tray 4 (PF) Jam code During operation J14-01 The paper feed sensor /2 (PS78) does not turn ON within a specified period of time after the pick-up clutch /2 (CL9) turns ON. The pre-registration sensor /2 (PS93) does not turn ON within a specified period of time after the pick-up clutch / 2 (CL9) turns ON. J14-03 When the trailing edge of paper is passing through the loop sensor /2 (PS94), the pre-registration sensor /2 (PS93) is turned ON by the succeeding paper. When idling J14-04 The pre-registration sensor /2 (PS93) turns ON while in idling. Cause Resulting operation If there is a sheet of paper being printed when a jam occurs, the main body completes the paper exit before stopping operations.

13. JAM CODE Correction Pull out tray /4 and remove jammed paper if any. Open tray /4, the PF front door and the horizontal conveyance jam release lever and remove jammed paper if any.

J14-02

Pull out tray /4 and remove jammed paper if any.

During operation

Tray 5 (PF)

J15-01

The paper feed sensor /3 (PS84) does not turn ON within a specified period of time after the pick-up clutch /3 (CL12) turns ON. The pre-registration sensor /3 (PS95) does not turn ON within a specified period of time after the pick-up clutch / 3 (CL12) turns ON.

If there is a sheet of paper being printed when a jam occurs, the main body completes the paper exit before stopping operations.

Pull out tray /5 and remove jammed paper if any. Open tray /5, the PF front door and the vertical conveyance door / Lw, and remove jammed paper if any.

J15-02

J15-03

The vertical conveyance sensor /3 (PS96) does not turn ON within a specified period of time after the pre-registration sensor /3 (PS95) turns ON.

J15-04

When the trailing edge of paper is pass- After completion ing through the vertical conveyance sensor /3 (PS96), the pre-registration sensor /3 (PS95) is turned ON by the succeeding paper. When idling of the exit of the preceding paper, the main body stops operations. Open the PF front door and the vertical conveyance door /Lw and remove jammed paper if any. The pre-registration sensor /3 (PS95) turns ON while in idling. Pull out tray /5 and remove jammed paper if any.

J15-05

The vertical conveyance sensor /3 (PS96) turns ON while in idling.

J15-06

535

bizhub PRO 1050/1050P 1050e/1050eP

13. JAM CODE

Field Service Ver3.0 Nov.2006 Jam code During operation Cause The registration sensor (PS40) does not turn ON within a specified period of time after the ADU deceleration sensor (PS42) turns ON. The ADU deceleration sensor (PS42) does not turn ON within a specified period of time after the loop sensor (PS16) turns ON. Resulting operation If there is a sheet of paper being printed when a jam occurs, the main body completes the paper exit before stopping operations. After completion of the exit of the preceding paper, the main body stops operations. Open the main body vertical conveyance door and remove jammed paper if any. Open the main body front doors /R and /L, pull out the ADU section and remove jammed paper if any. Correction

bizhub PRO 1050/1050P /1050e/1050eP

Classification Paper feed conveyance (common to each tray) Paper feed conveyance (trays 1/ and /2) Paper feed conveyance (tray /2)

J17-01

J17-02

J17-03

The loop sensor (PS16) does not turn ON within a specified period of time after the vertical conveyance sensor /1 (PS19) turns ON.

J17-04

The vertical conveyance sensor /2 (PS20) does not turn ON within a specified period of time after the vertical conveyance sensor /3 (PS21) turns ON.

J17-05

The vertical conveyance sensor /1 (PS19) does not turn ON within a specified period of time after the vertical conveyance sensor /2 (PS20) turns ON.

Paper feed conveyance (PF)

J17-06

The loop sensor (PS16) does not turn ON within a specified period of time after the PF exit sensor (PS99) turns ON. When idling

Open the PF front door and the horizontal conveyance jam release lever, and remove jammed paper if any. Open the main body front doors /R and /L, pull out the ADU section and remove jammed paper if any.

Paper feed conveyance

J17-07 J17-08 J17-09 J17-10 J17-11

The paper leading edge sensor (PS41) turns ON while in idling. The registration sensor (PS40) turns ON while in idling. The ADU deceleration sensor (PS42) turns ON while in idling. The loop sensor (PS16) turns ON while in idling. The vertical conveyance sensor /2 (PS20) turns ON while in idling.

During operation

J17-12

The multi feed detection boards /1 and /2 detect a double feed.

If there is a sheet of paper being printed when a jam occurs, the main body completes the paper exit before stopping operations.

536

Field Service Ver3.0 Nov.2006 Classification Paper feed conveyance (PF) J18-02 Jam code During operation J18-01 The intermediate sensor /Up (PS91) does not turn ON within a specified period of time after the vertical conveyance sensor /1 (PS90) turns ON. The loop sensor /1 (PS92) does not turn ON within a specified period of time after the intermediate sensor /Up (PS91) turns ON. J18-03 The loop sensor /2 (PS94) does not turn ON within a specified period of time after the pre-registration sensor /2 (PS93) turns ON. J18-04 The intermediate sensor /Lw (PS97) does not turn ON within a specified period of time after the vertical conveyance sensor /3 (PS96) turns ON. J18-05 The loop sensor /3 (PS98) does not turn ON within a specified period of time after the intermediate sensor /Lw (PS97) turns ON. J18-06 The PF exit sensor (PS99) does not turn ON within a specified period of time after the loop sensor /1 (PS92) turns ON. Cause Resulting operation If there is a sheet of paper being printed when a jam occurs, the main body completes the paper exit before stopping operations.

13. JAM CODE Correction Open the PF front door and the PF vertical conveyance door /Up, and remove jammed paper if any.

Open the PF front door and the horizontal conveyance jam release lever, and remove jammed paper if any. Open the PF front door and the PF vertical conveyance door /Lw, and remove jammed paper if any.

Open the PF front door, the PF vertical conveyance door /Up and the horizontal conveyance jam release lever, and remove jammed paper if any.

J18-07

The PF exit sensor (PS99) does not turn ON within a specified period of time after the loop sensor /2 (PS94) turns ON.

Open the PF front door and the PF horizontal conveyance jam release lever, and remove jammed paper if any. Open the PF front door, the PF vertical conveyance door /Lw and the horizontal conveyance jam release lever, and remove jammed paper if any.

J18-08

The PF exit sensor (PS99) does not turn ON within a specified period of time after the loop sensor /3 (PS98) turns ON.

When idling

J18-09 J18-10

The intermediate sensor /Up (PS91) turns ON while in idling. The loop sensor /1 (PS92) turns ON while in idling.

Open the PF front door and the PF vertical conveyance door /Up, and remove jammed paper if any.

537

bizhub PRO 1050/1050P 1050e/1050eP

13. JAM CODE

Field Service Ver3.0 Nov.2006 Jam code When idling Cause The loop sensor /2 (PS94) turns ON while in idling. Resulting operation Open the PF front door and the horizontal conveyance jam release lever, and remove jammed paper if any. The intermediate sensor /Lw (PS97) turns ON while in idling. The loop sensor /3 (PS98) turns ON while in idling. Open the PF front door and the PF vertical conveyance door /Lw, and remove jammed paper if any. Open the PF front door and the horizontal conveyance jam release lever, and remove jammed paper if any. During operation Correction

bizhub PRO 1050/1050P /1050e/1050eP

Classification Paper feed conveyance (PF)

J18-11

J18-12 J18-13

J18-14

The PF exit sensor (PS99) turns ON while in idling.

Conveyance PF

J19-01

The main body vertical conveyance door is opened while in printing. The PF front door is opened while in printing. While in the print sequence, the maximum density sensor detects paper at the specified timing.

The main body stops immediately. The main body/ PF stops immediately. If there is a sheet of paper being printed when a jam occurs, the main body completes the paper exit before stopping operations.

Close the vertical conveyance door. Close the PF front door.

J19-02

Fusing/ paper exit

J21-01

Open the main body front doors /R and /L, pull out the ADU section and remove jammed paper if any.

When idling

J21-02

While in idling, the maximum density sensor detects paper at the specified timing. The paper leading edge sensor (PS41) does not turn ON within a specified period of time after the registration motor (M17) turns no. The fusing exit sensor (PS22) does not turn ON within a specified period of time after the paper leading edge sensor (PS41) turns ON.

During operation

J31-01

If there is a sheet of paper being printed when a jam occurs, the main body completes the paper exit before stopping operations.

J31-02

J32-01

The paper exit sensor (PS3) does not turn ON within a specified period of time after the fusing exit sensor (PS22) turns ON.

538

Field Service Ver3.0 Nov.2006 Classification Fusing/ paper exit J32-03 Jam code During operation J32-02 The ADU acceleration sensor (PS49) does not turn ON within a specified period of time after the fusing exit sensor (PS22) turns ON. The reverse sensor /1 (PS48) does not turn ON within a specified period of time after the ADU acceleration sensor (PS49) turns ON. J32-04 The PS46 does not turn ON again within a specified period of time after the reverse sensor /1 (PS48) turns ON. J32-05 The paper exit sensor (PS3) does not turn ON within a specified period of time after the reverse sensor /1 (PS48) turns ON. J32-06 The paper exit sensor (PS3) does not turn OFF within a specified period of time after the PS3 turns ON. When idling J32-07 J32-08 J32-09 J32-10 J32-11 J32-12 J32-13 During operation External J51-01 The paper exit sensor (PS3) turns ON while in idling. The ADU acceleration sensor (PS49) turns ON while in idling. The fusing exit sensor (PS22) turns ON while in idling. The reverse/exit sensor (PS50) turns ON while in idling. The fusing jam sensor (PS23) turns ON while in idling. The reverse sensor /1 (PS48) turns ON while in idling. The reverse sensor /2 (PS47) turns ON while in idling. The front door/R, /L of the main body was opened while printing. The main body stops immediately. Cause Resulting operation If there is a sheet of paper being printed when a jam occurs, the main body completes the paper exit before stopping operations.

13. JAM CODE Correction Open the main body front doors /R and /L, pull out the ADU section and remove jammed paper if any.

Open the main body front doors /R and /L, pull out the ADU section and remove jammed paper if any.

539

bizhub PRO 1050/1050P 1050e/1050eP

13. JAM CODE

Field Service Ver3.0 Nov.2006 Jam code During operation Cause The RADF open/close sensor (PS301) turns OFF while in operation. The cover open/close switch (MS301) turns OFF while in operation. The original registration sensor /Rt (PS306) does not turn OFF within a specified period of time after the prefeed start. Resulting operation The DF stops immediately. If there is paper being transferred or having been transferred, the main body completes the paper exit before stopping operations. Open the DF open/close cover and remove jammed paper if any. Correction

bizhub PRO 1050/1050P /1050e/1050eP

Classification DF

J61-1 J61-2 J62-1

J62-2

The original conveyance sensor (PS308) does not turn ON within a specified period of time after the prefeed start of the front side of the double sided original (including the single sided original).

J62-3

The original conveyance sensor (PS308) does not turn ON within a specified period of time after the prefeed start of the back side of the double sided original.

J62-4

While in the forward rotation of the original conveyance motor (M301), the original conveyance sensor (PS308) does not turn OFF within a specified period of time after it turns ON.

J62-5

While in the reverse rotation of the original conveyance motor (M301), the original conveyance sensor (PS308) does not turn OFF within a specified period of time after it turns ON.

J62-6

When entering a large size double sided original in the reverse section, the original reverse sensor (PS309) does not turn ON within a specified period of time after the original conveyance sensor (PS308) turns ON.

J62-7

When exiting a large size single sided original, the original exit sensor /Lt (PS307) does not turn ON within a specified period of time after the original conveyance sensor (PS308) turns ON.

540

Field Service Ver3.0 Nov.2006 Classification DF Jam code During operation J62-8 When exiting a large size double sided original, the original exit sensor /Lt (PS307) does not turn ON within a specified period of time after the original reverse sensor (PS309) turns ON. When exiting a large size single sided original, the original exit sensor /Lt (PS307) does not turn OFF within a specified period of time after it turns ON. J62-10 When exiting a large size double sided original, the original exit sensor /Lt (PS307) does not turn OFF within a specified period of time after it turns ON. J63-1 When outputting a large size double sided original from the reverse section, the original reverse sensor (PS309) does not turn ON. J63-2 When entering a large size double sided original into the reverse section, the original reverse sensor (PS309) does not turn OFF within a specified period of time after it turns ON. J63-3 When outputting a large size double sided original from the reverse section, the original reverse sensor (PS309) does not turn OFF within a specified period of time after it turns ON. J63-4 When exiting a small size single sided original, the original exit sensor /Rt (PS314) does not turn OFF within a specified period of time after the original reverse sensor (PS309) turns ON. J63-5 When exiting a small size double sided original, the original exit sensor /Rt (PS314) does not turn OFF within a specified period of time after the original reverse/exit sensor (PS313) turns ON. J63-6 When exiting a small size single sided original, the original exit sensor /Rt (PS314) does not turn OFF within a specified period of time after it turns ON. Cause Resulting operation The DF stops immediately. If there is paper being transferred or having been transferred, the main body completes the paper exit before stopping operations.

13. JAM CODE Correction Open the DF open/close cover and remove jammed paper if any.

J62-9

541

bizhub PRO 1050/1050P 1050e/1050eP

13. JAM CODE

Field Service Ver3.0 Nov.2006 Jam code During operation Cause When exiting a small size double sided original, the original exit sensor /Rt (PS314) does not turn OFF within a specified period of time after it turns ON. When entering a small size double sided original into the reverse section, the original reverse sensor (PS309) does not turn ON within a specified period of time after original conveyance sensor (PS308) turns ON. Resulting operation The DF stops immediately. If there is paper being transferred or having been transferred, the main body completes the paper exit before stopping operations. Open the DF open/close cover and remove jammed paper if any. Correction

bizhub PRO 1050/1050P /1050e/1050eP

Classification DF

J63-7

J63-8

J63-9

When outputting a small size double sided original from the reverse section, the original reverse sensor (PS309) does not turn ON within a specified period of time after original conveyance sensor (PS308) turns ON.

J63-10

When entering a small size double sided original into the reverse section, the original reverse sensor (PS309) does not turn OFF within a specified period of time after it turns ON.

J63-11

When outputting a small size double sided original from the reverse section, the original reverse sensor (PS309) does not turn OFF within a specified period of time after it turns ON.

J65-1 J65-2 J65-4 J65-8 J65-10 J65-20 J65-40 J65-80

The original registration sensor /Rt (PS306) turns ON while in idling. The original conveyance sensor (PS308) turns ON while in idling. The original reverse sensor (PS309) turns ON while in idling. The original exit sensor /Lt (PS307) turns ON while in idling. The original reverse/exit sensor (PS313) turns ON while in idling. The original exit sensor /Rt (PS314) turns ON while in idling. The reverse jam sensor (PS304) turns ON while in idling. The original registration sensor /Lt (PS318) turns ON while in idling.

542

Field Service Ver3.0 Nov.2006 Classification FD Jam code During operation J72-01 The FD entrance sensor (PS1) does not turn ON within a specified period of sor (PS3) turns ON. The intermediate conveyance sensor (PS13) does not turn ON within a specified period of time after the FD entrance sensor (PS1) turns ON. J72-03 The main tray exit sensor (PS18) does not turn ON within a specified period of time after the intermediate conveyance sensor (PS13) turns ON. J72-04 The main tray exit sensor (PS18) does not turn OFF within a specified period of time after it turns ON. J72-05 The sub tray paper exit sensor (PS16) does not turn ON within a specified period of time after the intermediate conveyance sensor (PS13) turns ON. J72-06 The sub tray paper exit sensor (PS16) does not turn OFF within a specified period of time after it turns ON. J72-09 The punch conveyance sensor (PS5) does not turn ON within a specified period of time after the FD entrance sensor (PS1) turns ON. J72-10 The 3rd folding conveyance sensor (PS54) does not turn ON within a specified period of time after the punch conveyance sensor (PS5) turns ON. J72-11 The punch registration sensor (PS6) does not turn ON within a specified period of time after the punch conveyance sensor (PS5) turns ON. J72-12 The 1st folding conveyance sensor (PS51) does not turn ON within a specified period of time after the punch registration sensor (PS6) turns ON. J72-13 The 3rd folding conveyance sensor (PS54) does not turn ON within a specified period of time after the 1st folding conveyance sensor (PS51) turns ON. J72-14 The intermediate conveyance sensor (PS13) does not turn ON within a specified period of time after the 3rd folding conveyance sensor (PS54) turns ON. Cause Resulting operation The FD and the main body stop

13. JAM CODE Correction Remove jammed paper if any from the FD/main body.

time after the main body paper exit sen- immediately.

J72-02

543

bizhub PRO 1050/1050P 1050e/1050eP

13. JAM CODE

Field Service Ver3.0 Nov.2006 Jam code During operation Cause The FNS entrance sensor (PS4) does not turn ON within a specified period of time after the main body paper exit sensor (PS3) turns ON. The main tray exit sensor (PS10) does not turn OFF within a specified period of time after the stacker entrance sensor (PS5) turns OFF. Resulting operation The FS and the main body stop immediately. Remove jammed paper, if any, from the FS/main body. Correction

bizhub PRO 1050/1050P /1050e/1050eP

Classification FS

J72-16

J72-17

J72-18

The stacker entrance sensor (PS5) does not turn ON within a specified period of time after the FNS entrance sensor (PS4) turns ON.

J72-19

While in stapling, the stacker entrance sensor (PS5) does not turn OFF within a specified period of time after the stacker entrance motor (M13) turns ON. While in any other operations than stapling, the PS5 does not turn OFF within a specified period of time after it turns ON.

J72-20

While in stapling a small size paper, the main tray exit sensor (PS10) does not turn ON within a specified period of time after the paper exit arm motor (M23) turns ON.

J72-21

While in stapling a large size paper, the main tray exit sensor (PS10) does not turn OFF within a specified period of time after the paper exit arm motor (M23) turns ON.

J72-22

While in exiting paper in the sub tray, the sub tray paper exit sensor (PS1) does not turn ON within a specified period of time after the FNS entrance sensor (PS4) turns ON.

J72-23

While in exiting paper in the sub tray, the sub tray paper exit sensor (PS1) does not turn OFF within a specified period of time after the PS1 turns ON.

J72-28

While in the straight/shift of the small size paper, the main tray paper exit sensor (PS10) does not turn OFF within a specified period of time after the PS10 turns ON.

544

Field Service Ver3.0 Nov.2006 Classification FS Jam code During operation J72-30 While in stapling a small size paper, the main tray paper exit sensor (PS10) does not turn OFF within a specified period of time after the PS10 turns ON. The door switch (MS1) turns OFF while in the copy/print. FD J72-40 While in the folding operation, the 2nd folding conveyance sensor (PS53) does not turn ON within a specified period of time after the 1st folding motor (M4) starts to accelerate. J72-41 While in the folding operation, the 3rd folding conveyance sensor (PS54) does not turn ON within a specified period of time after the 1st folding motor (M4) starts to accelerate. J72-42 While in the folding operation, the 3rd folding conveyance sensor (PS54) does not turn ON within a specified period of time after the 2nd folding motor (M5) starts to accelerate. J72-43 While in the folding operation, the intermediate conveyance sensor (PS13) does not turn ON within a specified period of time after the 3rd folding motor (M6) starts to accelerate. J72-44 While in the folding operation, the 3rd folding conveyance sensor (PS54) does not turn ON within a specified period of time after the 2nd folding conveyance sensor (PS53) turns ON. J72-45 While in the folding operation, the intermediate conveyance sensor (PS13) does not turn ON within a specified period of time after the 3rd folding conveyance sensor (PS54) turns ON. J72-46 The PI conveyance sensor /Up (PS31) does not turn ON within a specified period of time after the PI pick-up solenoid /Up (SD13) turns ON. J72-47 The PI exit sensor (PS4) does not turn ON within a specified period of time after the PI conveyance sensor /Up (PS31) turns ON. The copier stops immediately. The FD and the main body stop immediately. Cause Resulting operation The FS and the main body stop immediately.

13. JAM CODE Correction Remove jammed paper, if any, from the FS/main body. Close the front door. Remove jammed paper if any from the FD/main body.

J72-39

545

bizhub PRO 1050/1050P 1050e/1050eP

13. JAM CODE

Field Service Ver3.0 Nov.2006 Jam code During operation Cause The PI conveyance sensor /Lw (PS37) does not turn ON within a specified period of time after the PI pick-up solenoid /Lw (SD14) turns ON. The PI exit sensor (PS4) does not turn ON within a specified period of time after the PI conveyance sensor /Lw (PS37) turns ON. Resulting operation The FD and the main body stop immediately. Remove jammed paper if any from the FD/main body. Correction

bizhub PRO 1050/1050P /1050e/1050eP

Classification FD

J72-48

J72-49

J72-50

The FD entrance sensor (PS1) does not turn ON within a specified period of time after the PI exit sensor (PS4) turns ON.

J72-58 J72-59 SD J72-61

The PI multi feed is detected. The door switch (MS1) turns OFF. The entrance sensor (PS1) does not turn ON within a specified period of time after the exit sensor (PS3) on the main body turns ON. The SD and the main body stop immediately. Remove jammed paper if any from the SD/main body.

J72-62

The horizontal conveyance sensor /1 (PS2) does not turn ON within a specified period of time after the entrance sensor (PS1) turns ON.

J72-63

The horizontal conveyance sensor /2 (PS3) does not turn ON within a specified period of time after the horizontal conveyance sensor /1 (PS2) turns ON.

J72-64

The horizontal conveyance exit sensor (PS4) does not turn ON within a specified period of time after the horizontal conveyance sensor /2 (PS3) turns ON.

J72-65

The horizontal conveyance exit sensor (PS4) does not turn OFF within a specified period of time after it turns ON.

J72-66

The subtray exit sensor (PS11) does not turn ON within a specified period of time after the horizontal conveyance sensor /1 (PS2) turns ON.

J72-67

The subtray exit sensor (PS11) does not turn OFF within a specified period of time after it turns ON.

J72-68

The entrance sensor (PS1) does not turn ON within a specified period of time after the exit sensor (PS3) on the main body turns ON.

546

Field Service Ver3.0 Nov.2006 Classification SD Jam code During operation J72-69 The right angle conveyance sensor /2 (PS6) does not turn ON within a specified period of time after the right angle conveyance motor (M6) turns ON. The folding sensor /1 (PS7) does not turn ON within a specified period of time after the folding entrance motor (M3) turns ON. J72-71 The saddle stitching paper sensor (PS13) does not turn ON within a specified period of time after the folding sub scan alignment exit motor (M8) turns ON. J72-72 The bundle sensor /1 (PS14) does not turn ON within a specified period of time after the bundle arm rotation motor (M22) turns ON. J72-73 The bundle sensor /2 (PS15) does not turn ON within a specified period of time after the bundle clip motor (M11) turns ON. J72-74 The bundle sensor /4 (PS54) does not turn ON within a specified period of time after the bundle sensor /2 (PS15) turns ON. J72-75 The entrance sensor (PS1) does not turn Off within a specified period of time after it turns ON. J72-76 The horizontal conveyance sensor (PS3) does not turn OFF within a specified period of time after the entrance sensor (PS1) turns ON. J72-77 The right angle conveyance sensor /2 (PS6) does not turn OFF within a specified period of time after the folding entrance motor (M3) turns ON. J72-78 The folding sensor /2 (PS44) does not turn OFF within a specified period of time after the folding sub scan alignment exit motor (M8) turns ON. J72-79 The saddle stitching paper sensor (PS13) does not turn OFF within a specified period of time after the folding sub scan alignment exit motor (M8) turns ON. Cause Resulting operation The SD and the main body stop immediately.

13. JAM CODE Correction Remove jammed paper if any from the SD/main body.

J72-70

547

bizhub PRO 1050/1050P 1050e/1050eP

13. JAM CODE

Field Service Ver3.0 Nov.2006 Jam code During operation Cause The bundle sensor /1 (PS14) does not turn OFF within a specified period of time after the bundle clip motor (M11) turns ON. The bundle sensor /2 (PS15) does not turn OFF within a specified period of time after the bundle registration motor (M12) turns ON. Resulting operation The SD and the main body stop immediately. Remove jammed paper if any from the SD/main body. Correction

bizhub PRO 1050/1050P /1050e/1050eP

Classification SD

J72-80

J72-81

J72-82

With paper bundle exit, the bundle sensor /4 (PS54) does not turn OFF within a specified period of time after the bundle registration motor (M12) turns ON.

J72-83

The folding passage sensor (PS8) does not turn ON within a specified period of time after the folding conveyance motor (M4) turns ON.

J72-84

The tri-folding exit sensor (PS9) does not turn ON within a specified period of time after the folding conveyance motor (M4) turns ON.

J72-85

The folding sub scan alignment exit motor (M8) does not turn OFF within a specified period of time after it turns ON.

J72-86

The folding passage sensor (PS8) does not turn OFF within a specified period of time after the folding conveyance motor (M4) turns ON.

J72-87

The tri-folding exit sensor (PS9) does not turn OFF within a specified period of time after it turns ON.

J72-88

With paper bundle exit, the bundle sensor /2 (PS15) does not turn OFF within a specified period of time after it turns ON.

J72-89

The trimmer registration sensor (PS55) does not turn OFF within a specified period of time after the bundle press movement motor (M17) turns ON.

J72-90

The trimmer registration sensor (PS55) does not turn ON within a specified period of time after the bundle registration motor (M12) turns ON.

J72-99 When idling FS J73-01 J73-02

During printing, either the SD front door switch /Rt (MS1) or /Lt (MS2) turns OFF. The stacker entrance sensor (PS5) turns ON while in idling. The FNS entrance sensor (PS4) turns ON while in idling. Open the FS front door and the jam release lever, and remove jammed paper, if any.

548

Field Service Ver3.0 Nov.2006 Classification FS Jam code When idling J73-03 The main tray paper exit sensor (PS10) turns ON while in idling. Or, the stack empty sensor (PS20) turns ON while turning ON the power source. The sub tray paper exit sensor (PS1) turns ON while in idling. FD J73-05 Either of the FD entrance sensor (PS1), the punch conveyance sensor (PS5) and the punch registration sensor (PS6) turns ON while in idling. Cause Resulting operation

13. JAM CODE Correction Open the FS front door and the jam release lever, and remove jammed paper, if any.

J73-04

Open the FD front door, open then the entrance conveyance jam release levers /1 and /2 and the punch conveyance jam release levers /1 and /2, and then remove jammed paper, if any.

J73-06

Either of the intermediate conveyance sensor (PS13), the sub tray paper exit sensor (PS16) and the main tray paper exit sensor (PS18) turns ON while in idling.

Open the FD front door and the intermediate conveyance jam lever, and remove the jammed paper, if any. Open the FD front door, pull out the folding conveyance section, open the folding conveyance jam release levers /1 to / 5, and remove jammed paper, if any. Open the FD upper door and remove jammed paper, if any. When jammed paper gets in the PI exit, open the entrance conveyance jam release lever /1 and remove the jammed paper.

J73-07

Either of the 1st folding conveyance sensor (PS51), the 2nd folding conveyance sensor (PS53), the 3rd folding conveyance sensor (PS54), the S size conveyance sensor (PS58), the folding entrance sensor (PS52) and the folding exit sensor (PS2) turns ON while in idling.

J73-08

Either of the PI conveyance sensor /Up (PS31), the PI conveyance sensor /Lw (PS37) and the PI exit sensor (PS4) turns ON while in idling.

SD

J73-09 J73-10

The entrance sensor (PS1) turns ON while in idling. Either of the horizontal conveyance sensor /1 (PS2), the horizontal conveyance sensor /2 (PS3), or the subtray exit sensor (PS11) turns ON while in idling.

Open the SD front door / Rt and remove jammed paper, if any.

J73-11

The horizontal conveyance exit sensor (PS4) turns ON while in idling.

Open the SD front door / Lt and remove jammed paper, if any.

549

bizhub PRO 1050/1050P 1050e/1050eP

13. JAM CODE

Field Service Ver3.0 Nov.2006 Jam code When idling Cause Either of the right angle conveyance sensor /1 (PS5) or the right angle conveyance sensor /2 (PS6) turns ON while in idling. Either of the folding sensor /1 (PS7), the folding passage sensor (PS8), the trifolding exit sensor, or the folding sensor /2 (PS44) turns ON while in idling. Resulting operation Open the SD front door / Rt and remove jammed paper, if any. Correction

bizhub PRO 1050/1050P /1050e/1050eP

Classification SD

J73-12

J73-13

J73-14 J73-15

The saddle stitching paper sensor (PS13) turns ON while in idling. Either of the bundle sensor /1 (PS14), the bundle sensor /2 (PS15), the bundle sensor /4 (PS54), or the bundle exit sensor /2 (PS57) turns ON while in idling.

Open the SD front door / Lt and remove jammed paper, if any.

LS

J73-17

The entrance sensor (PS4) of the tandem (1st) LS turns ON while in idling.

Open the tandem (1st) LS front door, open then entrance conveyance jam release lever and remove jammed paper, if any.

J73-18

The sub tray exit sensor (PS10) of the tandem (1st) LS turns ON while in idling.

Open the tandem (1st) LS sub tray cover, and remove jammed paper, if any.

J73-19

Either of the conveyance sensors /1, /2 and /3 (PS7, 16 and 17) of the tandem (1st) LS turns ON while in idling.

Open the tandem (1st) LS JAM door, and remove jammed paper, if any. Open the tandem (1st) LS front door, open then the coupling exit jam release lever, and remove jammed paper, if any.

J73-20

The coupling exit sensor (PS18) of the tandem (1st) LS turns ON while in idling.

J73-21

The entrance sensor (PS4) of the tandem (2nd) LS turns ON while in idling.

Open the tandem (2nd) LS front door, open then entrance conveyance jam release lever and remove jammed paper, if any.

J73-22

The sub tray paper exit sensor (PS10) of the tandem (2nd) LS turns ON while in idling.

Open the tandem (2nd) LS sub tray cover, and remove jammed paper, if any.

550

Field Service Ver3.0 Nov.2006 Classification LS Jam code When idling J73-23 Either of the conveyance sensors /1, /2 and /3 (PS7, 16 and 17) of the tandem (2nd) LS turns ON while in idling. However, in the case of LS-502, only the conveyance sensor /1 (PS7) is applicable. J73-24 The coupling exit sensor (PS18) of the tandem (2nd) LS turns ON while in idling. However, in the case of LS-501 only. PB J73-30 The entrance sensor (PS1) turns ON while in idling. The SC entrance sensor (PS2) turns ON while in idling. The cover paper entrance sensor (PS3) turns ON while in idling. The sub tray exit sensor (PS4) turns ON while in idling. J73-31 J73-32 J73-33 The SC paper detection sensor (PS16) turns ON while in idling. The clamp paper sensor (PS28) turns ON while in idling. The cover paper switchback sensor (PS44) turns ON while in idling. The cover paper sensor/Rt (PS45) turns ON while in idling. The cover paper sensor/Lt (PS46) turns ON while in idling. J73-34 The book end sensor (PS61) turns ON while in idling. J73-35 The cover paper conveyance sensor /1 (PS75) turns ON while in idling. The cover paper conveyance sensor /2 (PS76) turns ON while in idling. The cover paper conveyance sensor /3 (PS77) turns ON while in idling. The cover paper conveyance sensor /4 (PS78) turns ON while in idling. The cover paper conveyance sensor /5 (PS79) turns ON while in idling. Cause Resulting operation

13. JAM CODE Correction Open the tandem (2nd) LS JAM door, and remove jammed paper, if any.

Open the tandem (2nd) LS front door, open then the coupling exit jam release lever and remove jammed paper, if any. Open the front door and remove jammed paper, if any.

Open the upper door and remove jammed paper, if any. Open the front door and remove jammed paper, if any.

Open the stacker door and remove jammed paper, if any. Pull out the paper feed tray and remove jammed paper, if any.

551

bizhub PRO 1050/1050P 1050e/1050eP

13. JAM CODE

Field Service Ver3.0 Nov.2006 Jam code During operation Cause The entrance sensor (PS4) of the tandem (1st) LS does not turn ON within a specified period of time after the main body paper exit sensor (PS3) turns ON. The entrance sensor (PS4) of the tandem (1st) LS does not turn OFF within a specified period of time after it turns ON. During operation Resulting operation The LS and the main body stop immediately. Remove jammed paper, if any, from the LS/main body. Correction

bizhub PRO 1050/1050P /1050e/1050eP

Classification LS

J74-01

J74-02

J74-03

The sub tray exit sensor (PS10) does not turn ON within a specified period of time after the entrance sensor (PS4) of the tandem (1st) LS turns ON. The sub tray exit sensor (PS10) of the tandem (1st) LS does not turn OFF within a specified period of time after it turns ON.

J74-04

J74-05

The conveyance sensor /1 (PS7) does not turn ON within a specified period of time after the entrance sensor (PS4) of the tandem (1st) LS turns ON.

J74-06

The conveyance sensor /1 (PS7) of the tandem (1st) LS does not turn OFF within a specified period of time after it turns ON.

J74-07

The conveyance sensor /2 (PS16) does not turn ON within a specified period of time after the conveyance sensor /1 (PS7) of the tandem (1st) LS turns ON.

J74-08

The conveyance sensor /2 (PS16) of the tandem (1st) LS does not turn OFF within a specified period of time after it turns ON.

J74-09

The conveyance sensor /3 (PS17) does not turn ON within a specified period of time after the conveyance sensor /2 (PS16) of the tandem (1st) LS turns ON.

J74-10

The conveyance sensor /3 (PS17) of the tandem (1st) LS does not turn OFF within a specified period of time after it turns ON.

J74-11

The coupling exit sensor (PS18) does not turn ON within a specified period of time after the conveyance sensor /3 (PS17) of the tandem (1st) LS turns ON.

552

Field Service Ver3.0 Nov.2006 Classification LS Jam code During operation J74-12 The coupling exit sensor (PS18) of the tandem (1st) LS does not turn OFF within a specified period of time after it turns ON. The LS front door open jam. While in any other modes than the tandem mode, the front door switch (MS1) of the tandem (1st) LS turns OFF while in the print/print. J74-31 The entrance sensor (PS4) of the tandem (2nd) LS does not turn ON within a specified period of time after the coupling exit sensor (PS18) of the tandem (1st) LS turns ON. J74-32 The entrance sensor (PS4) of the tandem (2nd) LS does not turn OFF within a specified period of time after it turns ON. J74-33 The sub tray exit sensor (PS10) does not turn ON within a specified period of time after the entrance sensor (PS4) of the tandem (2nd) LS turns ON. J74-34 The sub tray exit sensor (PS10) of the tandem (2nd) LS does not turn OFF within a specified period of time after it turns ON. J74-35 The conveyance sensor /1 (PS7) does not turn ON within a specified period of time after the entrance sensor (PS4) of the tandem (2nd) LS turns ON. J74-36 The conveyance sensor /1 (PS7) of the tandem (2nd) LS does not turn OFF within a specified period of time after it turns ON. J74-37 The conveyance sensor /2 (PS16) does not turn ON within a specified period of time after the conveyance sensor /1 (PS7) of the tandem (2nd) LS turns ON. J74-38 The conveyance sensor /2 (PS16) of the tandem (2nd) LS does not turn OFF within a specified period of time after it turns ON. J74-39 The conveyance sensor /3 (PS17) does not turn ON within a specified period of time after the conveyance sensor /2 (PS16) of the tandem (2nd) LS turns ON. Cause Resulting operation The LS and the main body stop immediately.

13. JAM CODE Correction Remove jammed paper, if any, from the LS/main body.

J74-19

553

bizhub PRO 1050/1050P 1050e/1050eP

13. JAM CODE

Field Service Ver3.0 Nov.2006 Jam code During operation Cause The conveyance sensor /3 (PS17) of the tandem (1st) LS does not turn OFF within a specified period of time after it turns ON. The coupling exit sensor (PS18) does not turn ON within a specified period of time after the conveyance sensor /3 (PS17) of the tandem (2nd) LS turns ON. Resulting operation The LS and the main body stop immediately. Remove jammed paper, if any, from the LS/main body. Correction

bizhub PRO 1050/1050P /1050e/1050eP

Classification LS

J74-40

J74-41

J74-42

The coupling exit sensor (PS18) of the tandem (2nd) LS does not turn OFF within a specified period of time after it turns ON.

J74-49

The LS front door open jam. While in any other modes other than the tandem mode, the front door switch (MS1) of the tandem (2nd) LS turns OFF while in the print/print.

PB

J74-60

The entrance sensor (PS1) does not turn ON within a specified period of time after the main body paper exit sensor (PS3) turns ON.

The PB and the main body stop immediately.

Remove jammed paper, if any, from the PB/main body.

J74-61

The SC entrance sensor (PS2) does not turn ON within a specified period of time after the entrance sensor (PS1) turns ON.

J74-62

The SC entrance sensor (PS2) does not turn OFF within a specified period of time after it turns ON.

J74-63

The cover paper entrance sensor (PS3) does not turn ON within a specified period of time after the main body paper exit sensor (PS3) turns ON.

J74-64

The sub tray exit sensor (PS4) does not turn ON within a specified period of time after the entrance sensor (PS1) turns ON.

J74-65

The sub tray exit sensor (PS4) does not turn OFF within a specified period of time after it turns ON.

J74-66

The SC paper detection sensor (PS16) does not turn ON within a specified period of time after the SC entrance sensor (PS2) turns ON.

554

Field Service Ver3.0 Nov.2006 Classification PB Jam code During operation J74-67 The SC paper detection sensor (PS16) does not turn OFF within a specified period of time after it turns ON. When conveying two pages at a time, the SC paper detection sensor (PS16) does not turn ON within a specified time period after the SC entrance sensor (PS2) turns ON. J74-69 When conveying two pages at a time, the SC paper detection sensor (PS16) does not turn OFF within a specified period of time after it turns ON. J74-70 The SC paper detection sensor (PS16) does not turn OFF within a specified period of time after the SC bundle conveynace motor (M17) turns ON. J74-71 The clamp paper sensor (PS28) does not turn OFF within a specified period of time after the Clamp motor (M22) turns OFF. J74-72 The glue apply position detection sensor (PS32) does not turn ON within a specified period of time after reversal of glue tank movement motor (the tank moves back) turns ON. J74-73 The glue apply position detection sensor (PS32) does not turn OFF within a specified period of time after it turns ON. J74-74 The cover paper sensor/Rt (PS45) does not turn ON within a specified period of time after the cover paper pick up clutch (MC71) turns ON. J74-76 When starting trimming of the cover paper fed from the PB, the cover paper switchback sensor (PS44) does not turn ON within a specified time period after the cover paper conveyance motor (M45) turns ON. J74-77 When trimming of the cover paper fed from the PB is complete, the cover paper switchback sensor (PS44) does not turn OFF within a specified time period after the cover paper conveyance motor (M45) turns ON. Cause Resulting operation The PB and the main body stop immediately.

13. JAM CODE Correction Remove jammed paper, if any, from the PB/main body.

J74-68

555

bizhub PRO 1050/1050P 1050e/1050eP

13. JAM CODE

Field Service Ver3.0 Nov.2006 Jam code During operation Cause When positioning the leading edge of the cover paper fed from the PB, the cover paper sensor/Lt (PS46) does not turn OFF within a specified time period after the cover paper conveyance motor (M45) turns ON. When positioning the leading edge of the cover paper fed from the PB, the cover paper sensor/Lt (PS46) does not turn ON within a specified time period after the cover paper conveyance motor (M45) turns ON. Resulting operation The PB and the main body stop immediately. Remove jammed paper, if any, from the PB/main body. Correction

bizhub PRO 1050/1050P /1050e/1050eP

Classification PB

J74-78

J74-79

J74-80

When cover paper is fed from the main body, the cover paper sensor/Rt (PS45) does not turn OFF within a specified time period after the cover paper entrance sensor (PS3) turns ON.

J74-82

When starting trimming of the cover paper fed from the main body, the cover paper switchback sensor (PS44) does not turn ON within a specified period of time after the cover paper conveyance motor (M45) turns ON.

J74-83

When trimming of the cover paper fed from the main body is complete, the cover paper switchback sensor (PS44) does not turn OFF within a specified period of time after the cover paper conveyance motor (M45) turns ON.

J74-84

When positioning the leading edge of the cover paper fed from the main body, the cover paper sensor/Lt (PS46) does not turn OFF within a specified time period after the cover paper conveyance motor (M45) turns ON.

J74-85

When positioning the leading edge of the cover paper fed from the main body, the cover paper sensor/Lt (PS46) does not turn ON within a specified time period after the cover paper conveyance motor (M45) turns ON.

J74-86

The book end sensor (PS61) does not turn ON within a specified period of time after the book conveyance belt motor (M61) turns ON.

556

Field Service Ver3.0 Nov.2006 Classification PB Jam code During operation J74-87 When loading first book, the book sensor /1 (PS66) does not turn ON within a specified period of time after the book conveyance belt up down motor (M63) turns ON. When first row of book moves, the book sensor /2 (PS67) does not turn ON within a specified period of time after the book movement motor (M64) turns ON. J74-89 When feeding paper, the cover paper conveyance sensor /1 (PS75) does not turn ON within a specified period of time after the cover paper pick up clutch (MC71) turns ON. J74-90 The cover paper conveyance sensor /2 (PS76) does not turn ON within a specified period of time after the cover paper conveyance sensor /1 (PS75) turns ON. J74-91 When re-feeding paper, the cover paper conveyance sensor /3 (PS77) does not turn ON within a specified period of time after the cover paper pick up clutch (MC71) turns ON. J74-92 The cover paper conveyance sensor /4 (PS78) does not turn ON within a specified period of time after the cover paper conveyance sensor /3 (PS77) turns ON. J74-93 J74-96 The multi feed detection board /2 (MFDTB72) turns OFF. The cover paper switchback sensor (PS44) does not turn ON within a specified period of time after the cover paper feed motor (M74) turns ON. J74-97 No paper is detected (the paper has removed) when restarting the job after recovery. J74-98 A cover paper has not been conveyed to the cover paper table section when clamping of inside pages is finished. J74-99 The front door switch (MS2), the upper door switch (MS3) and the stacker door switch (MS4) became OFF during printing. Cause Resulting operation The PB and the main body stop immediately.

13. JAM CODE Correction Remove jammed paper, if any, from the PB/main body.

J74-88

557

bizhub PRO 1050/1050P 1050e/1050eP

13. JAM CODE

Field Service Ver3.0 Nov.2006 Jam code During operation Cause The ADU reverse sensor /1 (PS46) does not turn ON within a specified period of time after the reverse sensor /1 (PS48) turns ON. The ADU reverse sensor /1 (PS46) does not turn ON again within a specified period of time after the PS46 turns ON. When idling Resulting operation If there is a sheet of paper being printed when a jam occurs, the main body completes the paper exit before stopping operations. Open the main body front doors /R and /L, pull out the ADU section and remove jammed paper if any. Correction

bizhub PRO 1050/1050P /1050e/1050eP

Classification ADU

J92-01

J92-02

J92-03 J92-04 J93-01

The ADU reverse sensor /1 (PS46) turns ON while in idling. The ADU reverse sensor /2 (PS45) turns ON while in idling. The ADU exit sensor (PS43) does not turn ON within a specified period of time after the ADU reverse sensor /1 (PS46) turns ON.

During operation

If there is a sheet of paper being printed when a jam occurs, the main body completes the paper exit before stopping operations.

Open the main body front doors /R and /L, pull out the ADU section and remove jammed paper if any.

When idling

J93-02 J93-03 J94-01

The ADU conveyance sensor /1 (PS35) turns ON while in idling. The ADU conveyance sensor /2 (PS36) turns ON while in idling. The ADU deceleration sensor (PS42) does not turn ON within a specified period of time after the ADU exit sensor (PS43) turns ON.

During operation

If there is a sheet of paper being printed when a jam occurs, the main body completes the paper exit before stopping operations.

When idling

J94-03

The ADU exit sensor (PS43) turns ON while in idling.

558

Field Service Ver3.0 Nov.2006

14. MALFUNCTION CODE

14. MALFUNCTION CODE


14.1 Malfunction code list
A. Note for use Turn OFF/ON the power switch (SW2) of the main body when releasing an abnormal condition. B. Code list NOTE For codes with "*" in the code column, "Turn ON the power switch again" is displayed on the touch panel. For other codes, "Please call service" is displayed. For codes with "**" in the code column (SC78-40 to 62: perfect binding tank temperature abnormality related), always repair defective parts then set the DipSW3-1 software of service mode to 0. If DipSW3-1 is set to 0 before defective parts are fixed, it may cause fire.

Classification Main body Drive

Code

Causes

Resulting operation The main body stops immediately to turn OFF the RL1 (main).

Estimated abnormal parts Paper feed motor (M4) Printer control board (PRCB)

SC13-01 An abnormal speed signal of the paper feed motor (M4) is checked. An error detection signal is detected twice in succession a specified period of time after M4 was turned ON (the first signal is ignored).

PF

SC13-02 An abnormal speed signal of the PFU paper feed motor (M40) is checked. An error detection signal is detected twice in succession a specified period of time after M40 was turned ON (the first signal is ignored).

Paper feed motor (M40) PF drive board (PFUDB)

Main body

SC13-03 The blowout of a fuse for the vertical conveyance motor (M8) in the printer control board (PRCB) is checked. An error detection signal (blowout of a fuse) of M8 is detected when M8 is turned ON.

Printer control board (PRCB) Vertical conveyance motor (M8)

PF

SC13-05 The blowout of a fuse for the exit conveyance motor (M41) in the PF drive board (PFUDB) is checked. An error detection signal (blowout of a fuse) of M41 is detected when M41 is turned ON.

PF exit conveyance motor (M41) PF drive board (PFUDB)

559

bizhub PRO 1050/1050P 1050e/1050eP

14. MALFUNCTION CODE

Field Service Ver3.0 Nov.2006 Causes Resulting operation The main body stops immediately to turn OFF the RL1 (main). Error code is not displayed on the operation panel, but displayed only on the data collection, the list output and CSRC. Since the lifting operation of the tray is not completed, "Set paper in the tray 1" is displayed on the operation board. Paper lift motor /1 (M25) Printer control board (PRCB) DC power supply /2 (DCPS/ 2) Estimated abnormal parts Paper lift motor /1 (M25) Upper limit sensor /1 (PS6)

bizhub PRO 1050/1050P /1050e/1050eP

Classification Main body

Code

Tray /1 SC18-10 The locking of the paper lift motor /1 (M25) is detected. An error detection signal of M25 is detected while M25 is ON. SC18-11 When the upper limit sensor /1 (PS6) is OFF, PS6 does not turn ON within 20 seconds after the paper lift motor /1 (M25) turns ON for lifting operation. And at this time, an error detection signal (24V cut off) is detected. SC18-12 When the upper limit sensor /1 (PS6) is OFF, PS6 does not turn ON within 20 seconds after the paper lift motor /1 (M25) turns ON for lifting operation. And at this time, an error detection signal (blowout of a fuse) is detected. SC18-13 When the upper limit sensor /1 (PS6) is OFF, PS6 does not turn ON within 20 seconds after the paper lift motor /1 (M25) turns ON for lifting operation. And at this time, an error detection signal is not detected. Tray /2 SC18-20 The locking of the paper lift motor /2 (M26) is detected. When M26 is ON, an error detection signal of the M26 is detected. SC18-21 When the upper limit sensor /2 (PS12) is OFF, PS12 does not turn ON within 20 seconds after the paper lift motor /2 (M26) turns ON for lifting operation. And at this time, an error detection signal (24V cut off) is detected. SC18-22 When the upper limit sensor /2 (PS12) is OFF, PS12 does not turn ON within 20 seconds after the paper lift motor /2 (M26) turns ON for lifting operation. And at this time, an error detection signal (blowout of a fuse) is detected.

The main body stops immediately to turn OFF the RL1 (main). Error code is not displayed on the operation panel, but displayed only on the data collection, the list output and CSRC. Since the lifting operation of the tray is not completed, "Set paper in the tray 2" is displayed on the operation board.

Paper lift motor /2 (M26) Upper limit sensor /2 (PS12)

DC power supply /2 (DCPS/ 2)

Printer control board (PRCB)

560

Field Service Ver3.0 Nov.2006 Classification Main body Code Causes Resulting operation Tray /2 SC18-23 When the upper limit sensor /2 (PS12) is OFF, PS12 does not turn ON within 20 seconds after the paper lift motor /2 (M26) turns ON for lifting operation. And at this time, an error detection signal is not detected. Error code is not displayed on the operation panel, but displayed only on the data collection, the list output and CSRC. Since the lifting operation of the tray is not completed, "Set paper in the tray 2" is displayed on the operation board. PF Tray /3 SC18-30 The locking of the paper lift motor /1 (M42) is detected. When M42 is ON, an error detection signal of the M42 is detected. SC18-31 When the upper limit sensor /1 (PS71) is OFF, PS71 does not turn ON within 20 seconds after the paper lift motor /1 (M42) turns ON for lifting operation. And at this time, an error detection signal (24V cut off) is detected. SC18-32 When the upper limit sensor /1 (PS71) is OFF, PS71 does not turn ON within 20 seconds after the paper lift motor /1 (M42) turns ON for lifting operation. And at this time, an error detection signal (blowout of a fuse) is detected. SC18-33 When the upper limit sensor /1 (PS71) is OFF, PS71 does not turn ON within 20 seconds after the paper lift motor /1 (M42) turns ON for lifting operation. And at this time, an error detection signal is not detected. Tray /4 SC18-40 The locking of the paper lift motor /2 (M43) is detected. When M43 is ON, an error detection signal of the M43 is detected. The main body stops immediately to turn OFF the RL1 (main). The main body stops immediately to turn OFF the RL1 (main). Error code is not displayed on the operation panel, but displayed only on the data collection, the list output and CSRC. Since the lifting operation of the tray is not completed, "Set paper in the tray 3" is displayed on the operation board.

14. MALFUNCTION CODE Estimated abnormal parts Paper lift motor /2 (M26)

Paper lift motor /1 (M42) Upper limit sensor /1 (PS71)

DC power supply /2 (DCPS/ 2)

PF drive board (PFUDB)

Paper lift motor /1 (M42)

Paper lift motor /2 (M43) Upper limit sensor /2 (PS77)

561

bizhub PRO 1050/1050P 1050e/1050eP

14. MALFUNCTION CODE

Field Service Ver3.0 Nov.2006 Causes Resulting operation Error code is not displayed on the operation panel, but displayed only on the data collection, the list output and CSRC. Since the lifting operation of the tray is not completed, "Set paper in the tray 4" is displayed on the operation board. Error code is not displayed on the operation panel, but displayed only on the data collection, the list output and CSRC. Since the lifting operation of the tray is not completed, "Set paper in the tray 4" is displayed on the operation board. Paper lift motor /2 (M43) PF drive board (PFUDB) Estimated abnormal parts DC power supply /2 (DCPS/ 2)

bizhub PRO 1050/1050P /1050e/1050eP

Classification PF

Code

Tray /4 SC18-41 When the upper limit sensor /2 (PS77) is OFF, PS77 does not turn ON within 20 seconds after the paper lift motor /2 (M43) turns ON for lifting operation. And at this time, an error detection signal (24V cut off) is detected. SC18-42 When the upper limit sensor /2 (PS77) is OFF, PS77 does not turn ON within 20 seconds after the paper lift motor /2 (M43) turns ON for lifting operation. And at this time, an error detection signal (blowout of a fuse) is detected. SC18-43 When the upper limit sensor /2 (PS77) is OFF, PS77 does not turn ON within 20 seconds after the paper lift motor /2 (M43) turns ON for lifting operation. And at this time, an error detection signal is not detected.

Tray /5 SC18-50 The locking of the paper lift motor /3 (M44) is detected. When M44 is ON, an error detection signal of the M44 is detected. SC18-51 When the upper limit sensor /3 (PS83) is OFF, PS83 does not turn ON within 20 seconds after the paper lift motor /3 (M44) turns ON for lifting operation. And at this time, an error detection signal (24V cut off) is detected. SC18-52 When the upper limit sensor /3 (PS83) is OFF, PS83 does not turn ON within 20 seconds after the paper lift motor /3 (M44) turns ON for lifting operation. And at this time, an error detection signal (blowout of a fuse) is detected.

The main body stops immediately to turn OFF the RL1 (main). Error code is not displayed on the operation panel, but displayed only on the data collection, the list output and CSRC. Since the lifting operation of the tray is not completed, "Set paper in the tray 5" is displayed on the operation board.

Paper lift motor /3 (M44) Upper limit sensor /3 (PS83)

DC power supply /2 (DCPS/ 2)

PF drive board (PFUDB)

562

Field Service Ver3.0 Nov.2006 Classification PF Code Causes Resulting operation Tray /5 SC18-53 When the upper limit sensor /3 (PS83) is OFF, PS83 does not turn ON within 20 seconds after the paper lift motor /3 (M44) turns ON for lifting operation. And at this time, an error detection signal is not detected. Error code is not displayed on the operation panel, but displayed only on the data collection, the list output and CSRC. Since the lifting operation of the tray is not completed, "Set paper in the tray 5" is displayed on the operation board. Main body Wire cleaning abnormality SC21-01 It is checked that the time for the charger cleaning motor (M23) operations is over. home sensor (PS26) is OFF with the main power switch (SW1) ON, PS26 does not turn ON within 35 seconds after the M23 turns ON for home position an error research operation signal (return operation). At this time, detection (blowout of a fuse) is not detected. PS26 does not turn OFF within 15 seconds after the reverse operation (return operation) is started. At this time, an error detection signal (blowout of a fuse) is not detected. The charger cleaning limit sensor (PS27) does not turn ON within a specified period of time after the reverse operation (return operation) is started for detection of PS26 being OFF. Or, PS26 does not turn ON within a specified period of time after PS27 turns ON. At this time, an error detection signal (blowout of a fuse) is not detected. The main body stops immediately to turn OFF the

14. MALFUNCTION CODE Estimated abnormal parts Paper lift motor /3 (M44)

Charger cleaning motor (M23) Charger cleaning home sensor (PS26) Printer control board (PRCB)

When the charger cleaning RL1 (main).

563

bizhub PRO 1050/1050P 1050e/1050eP

14. MALFUNCTION CODE

Field Service Ver3.0 Nov.2006 Causes Resulting operation The main body stops immediately to turn OFF the RL1 (main). Estimated abnormal parts Charger cleaning motor (M23) Printer control board (PRCB)

bizhub PRO 1050/1050P /1050e/1050eP

Classification Main body Wire cleaning abnormality

Code

SC21-02 The blowout of a fuse for the charger cleaning motor (M23) in the printer control board (PRCB) is checked. When the charger cleaning home sensor (PS26) is OFF with the main power switch (SW1) ON, PS26 does not turn ON within 35 seconds after the M23 turns ON for home position research operation (return operation). And at this time, an error detection signal (blowout of a fuse) is detected. PS26 does not turn OFF within 15 seconds after the reverse operation (return operation) is started. And at this time, an error detection signal (blowout of a fuse) is detected. The charger cleaning limit sensor (PS27) does not turn ON within a specified period of time after the reverse operation (return operation) is started for detection of PS26 being OFF. Or, PS26 does not turn ON within a specified period of time after PS27 turns ON. At this time, an error detection signal (blowout of a fuse) is detected. SC21-03 The locking of the charger cleaning motor (M23) is detected. A motor lock signal is detected while moving from the charger cleaning limit sensor (PS27) side to the charger cleaning home sensor (PS26) side, and after a retry operation, a fifth motor lock signal is detected.

Charger cleaning motor (M23) Charger/cleaning member

564

Field Service Ver3.0 Nov.2006 Classification Main body Wire cleaning abnormality Code Causes Resulting operation SC21-04 It is checked that the operations of the transfer/separation cleaning motor (M20) are over. When the transfer/separation cleaning home sensor (PS38) is OFF with the main power switch (SW1) ON, PS38 does not turn ON within a specified period of time after the transfer/separation cleaning motor (M20) turns ON for a home position an error research operation signal (return operation). At this time, detection (blowout of a fuse) is not detected. PS38 does not turn OFF within a specified period of time after the reverse operation (return operation) is started. At this time, an error detection signal (blowout of a fuse) is not detected. The transfer/separation cleaning limit sensor (PS39) does not turn ON within a specified period of time after the reverse operation (return operation) is started for detection of PS38 being OFF. Or, PS38 does not turn ON within a specified period of time after PS39 turns ON. At this time, an error detection signal (blowout of a fuse) is not detected. The main body stops immediately to turn OFF the RL1 (main).

14. MALFUNCTION CODE Estimated abnormal parts Transfer/separation cleaning motor (M20) Transfer/separation cleaning home sensor (PS38) Transfer/separation cleaning limit sensor (PS39) ADU drive boards /1, /2 (ADUDB/1, /2)

565

bizhub PRO 1050/1050P 1050e/1050eP

14. MALFUNCTION CODE

Field Service Ver3.0 Nov.2006 Causes Resulting operation The main body stops immediately to turn OFF the RL1 (main). Estimated abnormal parts Transfer/separation cleaning motor (M20) ADU drive boards /1, /2 (ADUDB/1, /2)

bizhub PRO 1050/1050P /1050e/1050eP

Classification Main body Wire cleaning abnormality

Code

SC21-05 The blowout of a fuse for the transfer/separation cleaning motor (M20) in the ADU drive boards /1 and /2 (ADUDB/1 and /2)is checked. When the transfer/separation cleaning home sensor (PS38) is OFF with the main power switch (SW1) ON, PS38 does not turn ON within a specified period of time after the transfer/separation cleaning motor (M20) turns ON for a home position an error research operation signal (return operation). At this time, detection (blowout of a fuse) is detected. PS38 does not turn OFF within a specified period of time after the reverse operation (return operation) is started. At this time, an error detection signal (blowout of a fuse) is detected. PS39 does not turn ON within a specified period of time after the reverse operation (return operation) is started for detection of PS38 being OFF. Or, PS38 does not turn ON within a specified period of time after PS39 turns ON. At this time, an error detection signal (blowout of a fuse) is detected. SC21-06 The locking of the transfer/separation cleaning motor (M20) is detected. Motor lock signals are detected while moving from the transfer/ separation limit sensor (PS39) side to the transfer/separation home sensor (PS38) side, and after a retry operation, a fifth motor lock signal is detected.

Transfer/separation cleaning motor (M20) Transfer/separation charger/ Transfer/separation cleaning member

566

Field Service Ver3.0 Nov.2006 Classification Main body Wire cleaning abnormality Code Causes Resulting operation SC21-07 The home position search time of the transfer assist motor is out. The transfer assist home sensor (PS39) does not turn ON within a specified period of time after the home position search operation of the transfer assist motor (M19) is started. SC21-08 An error is detected while in the operation of the transfer assist motor. An error is detected of the transfer assist motor (M19) while in the print operation. Motor abnormality SC23-01 The speed error signal of the toner bottle motor (M6) is checked. An error detection signal is detected twice in succession a specified period of time after M6 turns ON (the first signal is ignored). SC23-02 The speed error signal of the developing motor (M3) is checked. Since an error detection signal is detected a second after M3 turns ON, turn OFF M3 for 0.5 seconds. Then, an error detection signal is detected again a second after it is turned ON again. SC23-03 The locking of the blade motor is detected. The error detection signal (over current) of M22 is detected. SC23-04 It is checked that the movement of the blade motor (M22) is not completed, and the 24V power source is also checked. The drum READY1 signal (READY condition) cannot be detected within a specified period of time after the drum motor (M2) turns ON. Or, the drum READY1 signal (READY release condition) cannot be detected within a specified period of time after M2 turns OFF. At this time, an error detection signal (24V cut out) is detected. The main body stops immediately to turn OFF the RL1 (main).

14. MALFUNCTION CODE Estimated abnormal parts Transfer assist motor (M19) Transfer assist home sensor (PS39) ADU drive boards /1, /2 (ADUDB/1, /2)

Transfer assist motor (M19) Transfer/separation cleaning limit sensor (PS39) Transfer assist home sensor (PS39) Toner bottle motor (M6) Printer control board (PRCB) Toner bottle/large capacity hopper

Developing motor (M3) Printer control board (PRCB)

Blade motor (M22) Blade sensor /1 (PS24), /2 (PS25) DC power supply /2 (DCPS/ 2)

567

bizhub PRO 1050/1050P 1050e/1050eP

14. MALFUNCTION CODE

Field Service Ver3.0 Nov.2006 Causes Resulting operation The main body stops immediately to turn OFF the RL1 (main). Estimated abnormal parts Blade motor (M22) Printer control board (PRCB)

bizhub PRO 1050/1050P /1050e/1050eP

Classification Main body Motor abnormality

Code

SC23-05 The blowout of a fuse for the blade motor (M22) in the printer control board (PRCB) is checked. The drum READY1 signal (READY condition) cannot be detected within a specified period of time after the drum motor (M2) turns ON. Or, the drum READY1 signal (READY release condition) cannot be detected within a specified period of time after M2 turns OFF. At this time, the error detection signal (blowout of a fuse) of the blade motor (M22) is detected. SC23-06 It is checked that the movement of the blade motor (M22) is not completed. The drum READY1 signal (READY condition) cannot be detected within a specified period of time after the drum motor (M2) turns ON. Or, the drum READY1 signal (READY release condition) cannot be detected within a specified period of time after M2 turns OFF. At this time, an error detection signal is not detected. SC23-07 It is checked that the movement of the blade motor (M22) is not completed, and 24V power source is also checked. The blade READY signal (READY condition) cannot be detected within a specified period of time after the blade replacement signal turns ON. Or, the blade READY signal (READY release condition) cannot be detected within a specified period of time after the blade replacement signal turns OFF. At this time, an error detection signal (24V cut off) is detected.

DC power supply /2 (DCPS/ 2)

568

Field Service Ver3.0 Nov.2006 Classification Main body Motor abnormality Code Causes Resulting operation SC23-08 The blowout of a fuse for the blade motor (M22) in the printer control board (PRCB) is checked. The blade READY signal (READY condition) cannot be detected within a specified period of time after the blade replacement signal turns ON. Or, the blade READY signal (READY release condition) cannot be detected within a specified period of time after the blade replacement signal turns OFF. At this time, an error detection signal (blowout of a fuse) of the blade motor (M22) is detected. SC23-09 It is checked that the movement of the blade motor (M22) is not completed. The blade READY signal (READY condition) cannot be detected within a specified period of time after the blade replacement signal turns ON. Or, the blade READY signal (READY release condition) cannot be detected within a specified period of time after the blade replacement signal turns OFF. At this time, an error detection signal is not detected. SC23-10 It is checked that the drum motor (M2) does not start. The drum READY2 signal (READY signal) is not detected within a specified period of time after M2 turns ON. SC23-11 The blowout of a fuse for the intermediate hopper motor (M11) in the printer control board (PRCB) is checked. An error detection signal (blowout of a fuse) is detected when M11 turns ON. The main body stops immediately to turn OFF the RL1 (main).

14. MALFUNCTION CODE Estimated abnormal parts Blade motor (M22) Printer control board (PRCB)

Drum motor (M2) Printer control board (PRCB)

Intermediate hopper motor (M11) Printer control board (PRCB)

569

bizhub PRO 1050/1050P 1050e/1050eP

14. MALFUNCTION CODE

Field Service Ver3.0 Nov.2006 Causes Resulting operation The main body stops immediately to turn OFF the RL1 (main). Estimated abnormal parts Air separation motor (M10) Printer control board (PRCB)

bizhub PRO 1050/1050P /1050e/1050eP

Classification Main body Motor abnormality

Code

SC23-12 The blowout of a fuse for the air separation motor (M10) in the printer control board (PRCB) is checked. An error detection signal (blowout of a fuse) is detected when M10 turns ON.

Toner conveyance abnormality

SC23-13 Air separation motor (M10) rotation abnormality. Since an error is detected when M10 turns ON, turn it OFF. An error is still detected when turn it ON again. SC23-14 The toner conveyance abnormality is detected. When toner is supplied for 8 minutes and the toner remaining sensor /1 (PS31) does not turn ON, it is found that the toner remaining sensor /3 (PS33) of the large capacity hopper turns ON for the last 15 seconds in succession.

Air separation motor (M10) Air motor encoder sensor (PS30) Resetting of the intermediate toner hopper section Toner pump motor (M28) Air pump motor (M29) Toner remaining sensor /1 (PS31) Toner remaining sensor /3 (PS33) Note: When the code SC2314 occurs, be sure to repair defective parts before 0. setting Setting the the software DIPSW3-1 to DIPSW3-1 to 0 without repairing defective parts may cause toner to overflow inside and outside of the machine.

SC23-15 Toner remaining detection sensor / 3 (PS33) abnormality. When the toner remaining sensor /1 (PS31) does not turn ON even if toner is supplied for 8 minutes, it is found that the toner remaining sensor /2 (PS32) of the large capacity hopper turns ON for the last 15 seconds in succession, and the toner remaining sensor /3 (PS33) turns OFF.

Toner remaining sensor /2 (PS32) Toner remaining sensor /3 (PS33)

570

Field Service Ver3.0 Nov.2006 Classification Main body Toner conveyance abnormality Code Causes Resulting operation SC23-17 Leakage at the mixing section is detected. When the toner pump motor (M28) is operating, the toner remaining sensor /4 (PS34) detects the toner being provided in succession for 20 seconds. The main body stops immediately to turn OFF the RL1 (main).

14. MALFUNCTION CODE Estimated abnormal parts Toner pump motor (M28) Air pump motor (M29) Toner remaining sensor /4 (PS34) Note: When the code SC2317 occurs, be sure to repair defective parts before 0. setting Setting the the software DIPSW3-1 to DIPSW3-1 to 0 without repairing defective parts may cause toner to overflow inside and outside of the machine.

SC23-20 Toner pump motor (M28) abnormality. The rotation of the toner pump motor (M28) and the 24 V power source are checked. While M28 is rotating, an error detection signal (abnormal rotation) is detected for more than 1 second. At this time, an error detection signal (24V cut off) is detected. SC23-21 Toner pump motor (M28)

DC power supply /2 (DCPS/ 2) Toner pump motor (M28)

Printer control board (PRCB) Toner pump motor (M28) Recycle cut motor (M30)

abnormality. The blowout of a fuse for the toner pump motor (M28) in the printer control board (PRCB) is checked. While M28 is rotating, an error detection signal (abnormal rotation) is detected for more than 1 second. At this time, an error detection signal (blowout of a fuse) is detected, but an error signal (24V cut off) is not detected. When recycle cut motor (M30) is operating, abnormality detection signal was continuously detected twice for the specified ignored) time. (First time

571

bizhub PRO 1050/1050P 1050e/1050eP

14. MALFUNCTION CODE

Field Service Ver3.0 Nov.2006 Causes Resulting operation The main body stops immediately to turn OFF the RL1 (main). Estimated abnormal parts Toner pump motor (M28) Pump encoder sensor /1 (PS28)

bizhub PRO 1050/1050P /1050e/1050eP

Classification Main body Toner conveyance abnormality

Code

SC23-22 Toner pump motor (M28) abnormality. The rotation of the toner pump motor (M28) is checked. While M28 is rotating, an error detection signal (abnormal rotation) is detected for more than 1 second. At this time, error signals (blowout of a fuse and 24V cut off) are not detected. SC23-24 Air pump motor (M29) abnormality. The rotation of the air pump motor (M29) and the 24V power source are checked. While M29 is rotating, an error detection signal (abnormal rotation) is detected for more than 1 second. At this time, an error signal (24V cut off) is detected. SC23-25 Air pump motor (M29) abnormality. The blowout of a fuse for the air pump motor (M29) in the printer control board (PRCB) is checked. While M29 is rotating, an error detection signal (abnormal rotation) is detected for more than 1 second. At this time, an abnormality signal (blowout of a fuse) is detected, but no abnormality signal (24V cut off) is detected. SC23-26 Air pump motor (M29) abnormality. The rotation of the air pump motor (M29) is checked for more than 1 second. An error detection signal (abnormal rotation) is detected for more than 1 second. At this time, error signals (blowout of a fuse and 24V cut off) are not detected.

DC power supply /2 (DCPS/ 2) Air pump motor (M29)

Printer control board (PRCB) Air pump motor (M29)

Air pump motor (M29) Pump encoder sensor (PS29) Load of the pump

572

Field Service Ver3.0 Nov.2006 Classification Main body Toner conveyance abnormality Code Causes Resulting operation SC-23-50 Toner collection box detected full When the waste toner amount exceeds 80% of the toner collection box, a warning message is displayed in the operation panel and the recycle cut motor (M30) is stopped after specific printing. Drum SC24-01 When the change in temperature of the drum temperature sensor (TH5) is less than -2C a specified period of time after the main power switch (SW1) turns ON to start the control of the dehumidification heater /1 (HTR1) and the drum temperature is below 10C after the elapse of 1 minute. SC24-02 When the main power switch (SW1) turns ON with the fusing temperature below 50C, the detected temperature of the drum temperature sensor (TH5) is more than 52C, and when the detected temperature is above 52C after a specified period of time. High voltage power source abnormality SC28-01 A charge leak is detected. After a charge error detection signal is detected while in the charge ON, up to 5 charge ON/OFF operations occur in succession while in 10 prints. SC28-02 A transfer leak is detected. After a transfer error detection signal is detected while in the transfer ON, up to 5 transfer ON/OFF operations occur in succession while in 10 prints. SC28-03 A separation leak is detected. After a separation error detection signal is detected while in the separation ON, up to 5 separation ON/OFF operations occur in succession while in 10 prints. The main body stops immediately to turn OFF the RL1 (main).

14. MALFUNCTION CODE Estimated abnormal parts Toner collection box

Drum temperature sensor (TH5)

Charger Power feeding contact High voltage unit /1 (HV1)

Transfer/separation charger Power feeding point High voltage unit /2 (HV2)

573

bizhub PRO 1050/1050P 1050e/1050eP

14. MALFUNCTION CODE

Field Service Ver3.0 Nov.2006 Causes Resulting operation The main body stops immediately to turn OFF the RL1 (main). Estimated abnormal parts ADU drive boards /1, /2 (ADUDB1, 2) High voltage unit /2 (HV2)

bizhub PRO 1050/1050P /1050e/1050eP

Classification Main body High voltage power source abnormality Process abnormality

Code

SC28-04 The error detection signal (blowout of a 24V fuse) of the high voltage unit /2 (HV2) is detected.

SC29-01 The dirt correction of the sensor is not completed. While in the maximum density correction, the dirt correction of the maximum density sensor is not sufficient. When this condition is detected 10 times in succession, the error code is displayed. SC29-02 The maximum density correction is not completed. While in the maximum density correction, the number of rotations of the developing sleeve gets to the maximum. SC29-03 The maximum density sensor output abnormality. While in the maximum density correction, a patch for control is not output. (No output is made from the maximum density sensor.) SC29-04 The dirt correction of the sensor is not completed. While in gamma correction, the dirt correction of the gamma sensor is not sufficient. When gamma sensor less than the specified value is detected ten times in succession, this error code is displayed. Error code is not displayed on the operation panel, but displayed only on the data collection, the list output and the CSRC. The control of the main body is made by using a data previously obtained. The main body stops immediately to turn OFF the RL1 (main).

Toner control sensor board (TCSB)

Toner control sensor board (TCSB) Developing motor (M3)

Toner control sensor board (TCSB) Write unit Image processing board (IPB) Overall control board (OACB) Toner control sensor board (TCSB) (gamma sensor cleaning required)

574

Field Service Ver3.0 Nov.2006 Classification Main body Process abnormality Code Causes Resulting operation SC29-05 The gamma sensor output abnormality. While in the gamma correction, a patch for control is not output. (No output is made from the gamma sensor.) Error code is not displayed on the operation panel, but displayed only on the data collection, the list output and the CSRC. SC29-06 The gamma correction data is defective. The gamma correction output is abnormal. A regression error when carrying out a gamma curve operation while in the gamma correction. SC29-07 The dirt correction of the sensor is not completed. While in the dot diameter correction, the dirt correction of the gamma sensor is not sufficient. When gamma sensor less than the specified value is detected five times in succession, this error code is displayed. SC29-08 Correction abnormality. While in the dot diameter correction, the correction is terminated with an abnormal value. Error code is not displayed on the operation panel, but displayed only on the data collection, the list output and the CSRC. The control of the main body is made by using a data previously obtained. SC29-09 Drum potential sensor (DPS) output abnormality. While in the 0V check of the DPS, more than 100V of the drum surface potential is detected more than 5 times. When the error code is detected 5 times in succession, this error code is displayed. The main body stops immediately to turn OFF the RL1 (main). The main body stops immediately to turn OFF the RL1 (main). The control of the main body is made by using a data previously obtained.

14. MALFUNCTION CODE Estimated abnormal parts Toner control sensor board (TCSB) Write unit Image processing board (IPB) Overall control board (OACB) Image processing board (IPB) Printer control board (PRCB)

Toner control sensor board (TCSB) (gamma sensor cleaning required)

Image processing board (IPB) Printer control board (PRCB)

Drum potential sensor (DPS) Printer control board (PRCB)

575

bizhub PRO 1050/1050P 1050e/1050eP

14. MALFUNCTION CODE

Field Service Ver3.0 Nov.2006 Causes Resulting operation The main body stops immediately to turn OFF the RL1 (main). Estimated abnormal parts Drum potential sensor (DPS) Printer control board (PRCB)

bizhub PRO 1050/1050P /1050e/1050eP

Classification Main body Process abnormality

Code

SC29-10 Drum potential sensor (DPS) output abnormality. While in the drum potential correction, a patch for control is not output with the V1 getting to more than 350V. When this condition is detected 5 times in succession, the error code is displayed. SC29-11 The data is defective. While in the drum potential correction, no convergence is obtained even after correction is made more than 10 times. When this condition is detected 5 times in succession, the error code is displayed. SC29-12 Auto adjustment monitor value abnormality. No convergence is made in the auto adjustment of the transfer current. SC29-13 Auto adjustment monitor value abnormality. No convergence is made in the auto adjustment of the separation (AC) current. SC29-14 Auto adjustment monitor value abnormality. No convergence is made in the auto adjustment of the separation (DC) current. SC29-15 Auto adjustment monitor value abnormality. No convergence is made in the auto adjustment of the developing bias. SC29-16 Drum charger capacity deterioration abnormality. When the charger grid/developing bias is in excess of the limit of correction, lower the developing potential/ fogging margin potential in steps of 50V. And as a result, less than 50V of the difference with the target charger potential is detected 10 times in succession.

Error code is not displayed on the operation panel, but displayed only on the data collection, the list output and the CSRC. The control of the main body is made by using a data previously obtained.

High voltage unit /2 (HV2)

High voltage unit /1 (HV1)

The main body stops immediately to turn OFF the RL1 (main).

Drum Drum potential sensor (DPS)

576

Field Service Ver3.0 Nov.2006 Classification Main body Fan abnormality Code Causes Resulting operation SC32-01 The rotation of the IPB cooling fan (FM12) is checked, and the 24V power source is also checked. An abnormal signal condition occurs a specified period of time after FM12 is turned ON. This abnormal condition recurs even a specified period of time after FM12 is turned OFF and then turned ON, and an error detection signal (24V cut off) is detected. SC32-02 The blowout of a fuse for the IPB cooling fan (FM12) in the AC drive board (ACDB) is checked. An abnormal condition occurs with the FM12 EM signal a specified period of time after FM12 is turned ON. This abnormal condition recurs even a specified period of time after FM12 is turned OFF and then turned ON, and an error detection signal (blowout of a fuse) is detected with the 24V normal. SC32-03 The rotation of the IPB cooling fan (FM12) is checked. An abnormal condition occurs with the FM12 EM signal a specified period of time after FM12 is turned ON. This abnormal condition recurs even a specified period of time after FM12 is turned OFF and then turned ON, and an error detection signal (24V cut off/blowout of a fuse) is not detected. SC32-04 When the print is started, the EM signal of the PB cooling fan (FM12) turns ON. Error code is not displayed on the operation panel, but displayed only on the data collection, the list output and the CSRC. The control of the main body is made by using a data previously obtained. The main body stops immediately to turn OFF the RL1 (main).

14. MALFUNCTION CODE Estimated abnormal parts DC power supply /1 (DCPS/ 1)

AC drive board (ACDB) IPB cooling fan (FM12)

AC drive board (ACDB) IPB cooling fan (FM12)

577

bizhub PRO 1050/1050P 1050e/1050eP

14. MALFUNCTION CODE

Field Service Ver3.0 Nov.2006 Causes Resulting operation The main body stops immediately to turn OFF the RL1 (main). Estimated abnormal parts DC power supply /2 (DCPS/ 2)

bizhub PRO 1050/1050P /1050e/1050eP

Classification Main body Fan abnormality

Code

SC32-05 The rotation of the pump cooling fan (FM11) is checked, and the 24V power source is also checked. An abnormal condition occurs with the FM11 EM signal a specified period of time after FM11 is turned ON. This abnormal condition recurs even a specified period of time after FM11 is turned OFF and then turned ON, and an error detection signal (24V cut off) is detected. SC32-06 The blowout of a fuse for the pump cooling fan (FM11) in the printer control board (PRCB) is checked. An abnormal condition occurs with the FM11 EM signal a specified period of time after FM11 is turned ON. This abnormal condition recurs even a specified period of time after FM11 is turned OFF and then turned ON, and an error detection signal (blowout of a fuse) is detected. SC32-07 The rotation of the pump cooling fan (FM11) is checked. An abnormal condition occurs with the FM11 EM signal a specified period of time after FM11 is turned ON. This abnormal condition recurs even a specified period of time after FM11 is turned OFF and then turned ON, and an error detection signal (24V cut off/blowout of a fuse) is not detected.

Pump cooling fan (FM11) Printer control board (PRCB)

Pump cooling fan (FM11) Printer control board (PRCB)

578

Field Service Ver3.0 Nov.2006 Classification Main body Fan abnormality Code Causes Resulting operation SC32-09 The rotation of the transfer/separation suction fan (FM4) is checked, and the 24V power source is also checked. An abnormal condition occurs with the FM4 EM signal a specified period of time after FM4 is turned ON. This abnormal condition recurs even a specified period of time after FM4 is turned OFF and then turned ON, and an error detection signal (24V cut off) is detected. SC32-10 The blowout of a fuse for the transfer/separation suction fan (FM4) in the printer control board (PRCB) is checked. An abnormal condition occurs with the FM4 EM signal a specified period of time after FM4 is turned ON. This abnormal condition recurs even a specified period of time after FM4 is turned OFF and then turned ON, and an error detection signal (blowout of a fuse) is detected with the 24V normal. SC32-11 The rotation of the transfer/separation suction fan (FM4) is checked. An abnormal condition occurs with the FM4 EM signal a specified period of time after FM4 is turned ON. This abnormal condition recurs even a specified period of time after FM4 is turned OFF and then turned ON, and an error detection signal (24V cut off/blowout of a fuse) is not detected. The main body stops immediately to turn OFF the RL1 (main).

14. MALFUNCTION CODE Estimated abnormal parts DC power supply /1 (DCPS/ 1)

Transfer/separation suction fan (FM4) Printer control board (PRCB)

Transfer/separation suction fan (FM4) Printer control board (PRCB)

579

bizhub PRO 1050/1050P 1050e/1050eP

14. MALFUNCTION CODE

Field Service Ver3.0 Nov.2006 Causes Resulting operation The main body stops immediately to turn OFF the RL1 (main). Estimated abnormal parts DC power supply /1 (DCPS/ 1)

bizhub PRO 1050/1050P /1050e/1050eP

Classification Main body Fan abnormality

Code

SC32-12 The rotation of the developing suction fan (FM5) is checked, and the 24V power source is also checked. An abnormal condition occurs with the FM5 EM signal a specified period of time after FM5 is turned ON. This abnormal condition recurs even a specified period of time after FM5 is turned OFF and then turned ON, and an error detection signal (24V cut off) is detected. SC32-13 The blowout of a fuse for the developing suction fan (FM5) in the printer control board (PRCB) is checked. An abnormal condition occurs with the FM5 EM signal a specified period of time after FM5 is turned ON. This abnormal condition recurs even a specified period of time after FM5 is turned OFF and then turned ON, and an error detection signal (blowout of a fuse) is detected with the 24V normal. SC32-14 The rotation of the developing suction fan (FM5) is checked. An abnormal condition occurs with the FM5 EM signal a specified period of time after FM5 is turned ON. This abnormal condition recurs even a specified period of time after FM5 is turned OFF and then turned ON, and an error detection signal (24V cut off/blowout of a fuse) is not detected.

Developing suction fan (FM5) Printer control board (PRCB)

Developing suction fan (FM5) Printer control board (PRCB)

580

Field Service Ver3.0 Nov.2006 Classification Main body Fan abnormality Code Causes Resulting operation SC32-15 The rotation of the paper exit cool- The main body ing fan /1 (FM9) is checked, and the 24V power source is also checked. An abnormal condition occurs with the FM9 EM signal a specified period of time after FM9 is turned ON. This abnormal condition recurs even a specified period of time after FM9 is turned OFF and then turned ON, and an error detection signal (24V cut off) is detected. SC32-16 The blowout of a fuse for the paper exit cooling fan /1 (FM9) in the printer control board (PRCB) is checked. An abnormal condition occurs with the FM9 EM signal a specified period of time after FM9 is turned ON. This abnormal condition recurs even a specified period of time after FM9 is turned OFF and then turned ON, and an error detection signal (blowout of a fuse) is detected with the 24V normal. SC32-17 The rotation of the paper exit cooling fan /1 (FM9) is checked. An abnormal condition occurs with the FM9 EM signal a specified period of time after FM9 is turned ON. This abnormal condition recurs even a specified period of time after FM9 is turned OFF and then turned ON, and an error detection signal (24V cut off/blowout of a fuse) is not detected. stops immediately to turn OFF the RL1 (main).

14. MALFUNCTION CODE Estimated abnormal parts DC power supply /1 (DCPS/ 1)

Paper exit cooling fan /1 (FM9) Printer control board (PRCB)

Paper exit cooling fan /1 (FM9) Printer control board (PRCB)

581

bizhub PRO 1050/1050P 1050e/1050eP

14. MALFUNCTION CODE

Field Service Ver3.0 Nov.2006 Causes Resulting operation The main body stops immediately to turn OFF the RL1 (main). Estimated abnormal parts DC power supply /1 (DCPS/ 1)

bizhub PRO 1050/1050P /1050e/1050eP

Classification Main body Fan abnormality

Code

SC32-18 The rotation of the paper exit cooling fan /2 (FM10) is checked, and the 24V power source is also checked. An abnormal condition occurs with the FM10 EM signal a specified period of time after FM10 is turned ON. This abnormal condition recurs even a specified period of time after FM10 is turned OFF and then turned ON, and an error detection signal (24V cut off) is detected. SC32-19 The blowout of a fuse for the paper exit cooling fans /2 (FM10) and /3 (FM28) in the printer control board (PRCB) is checked. An abnormal condition occurs with the FM10 EM signal a specified period of time after FM10 is turned ON. This abnormal condition recurs even a specified period of time after FM10 is turned OFF and then turned ON, and an error detection signal (blowout of a fuse) is detected with the 24V normal. SC32-20 The rotation of the paper exit cooling fans /2 (FM10) and /3 (FM28) is checked. An abnormal condition occurs with the FM10 EM signal a specified period of time after FM10 is turned ON. This abnormal condition recurs even a specified period of time after FM10 is turned OFF and then turned ON, and an error detection signal (24V cut off/blowout of a fuse) is not detected.

Paper exit cooling fans /2 (FM10), /3 (FM28)

Paper exit cooling fans /2 (FM10), /3 (FM28)

582

Field Service Ver3.0 Nov.2006 Classification Main body Fan abnormality Code Causes Resulting operation SC32-21 The rotation of the paper feed assist fan /Fr1 (FM20) is checked, and the 24V power source is also checked. An abnormal condition occurs with the FM20 EM signal a specified period of time after FM20 is turned ON. This abnormal condition recurs even a specified period of time after FM20 is turned OFF and then turned ON, and an error detection signal (24V cut off) is detected. SC32-22 The blowout of a fuse for the paper feed assist fan /Fr1 (FM20) in the printer control board (PRCB) is checked. An abnormal condition occurs with the FM20 EM signal a specified period of time after FM20 is turned ON. This abnormal condition recurs even a specified period of time after FM20 is turned OFF and then turned ON, and an error detection signal (blowout of a fuse) is detected with the 24V normal. SC32-23 The rotation of the paper feed assist fan /Fr1 (FM20) is checked. An abnormal condition occurs with the FM20 EM signal a specified period of time after FM20 is turned ON. This abnormal condition recurs even a specified period of time after FM20 is turned OFF and then turned ON, and an error detection signal (24V cut off/blowout of a fuse) is not detected. The main body stops immediately to turn OFF the RL1 (main).

14. MALFUNCTION CODE Estimated abnormal parts DC power supply /1 (DCPS/ 1)

Paper feed assist fan /Fr1 (FM20) Printer control board (PRCB)

Paper feed assist fan /Fr1 (FM20) Printer control board (PRCB)

583

bizhub PRO 1050/1050P 1050e/1050eP

14. MALFUNCTION CODE

Field Service Ver3.0 Nov.2006 Causes Resulting operation The main body stops immediately to turn OFF the RL1 (main). Estimated abnormal parts DC power supply /1 (DCPS/ 1)

bizhub PRO 1050/1050P /1050e/1050eP

Classification Main body Fan abnormality

Code

SC32-24 The rotation of the paper feed assist fan /Rr1 (FM21) is checked, and the 24V power source is also checked. An abnormal condition occurs with the FM21 EM signal a specified period of time after FM21 is turned ON. This abnormal condition recurs even a specified period of time after FM21 is turned OFF and then turned ON, and an error detection signal (24V cut off) is detected. SC32-25 The blowout of a fuse for the paper feed assist fan /Rr1 (FM21) in the printer control board (PRCB) is checked. An abnormal condition occurs with the FM21 EM signal a specified period of time after FM21 is turned ON. This abnormal condition recurs even a specified period of time after FM21 is turned OFF and then turned ON, and an error detection signal (blowout of a fuse) is detected with the 24V normal. SC32-26 The rotation of the paper feed assist fan /Rr1 (FM21) is checked. An abnormal condition occurs with the FM21 EM signal a specified period of time after FM21 is turned ON. This abnormal condition recurs even a specified period of time after FM21 is turned OFF and then turned ON, and an error detection signal (24V cut off/blowout of a fuse) is not detected.

Paper feed assist fan /Rr1 (FM21) Printer control board (PRCB)

Paper feed assist fan /Rr1 (FM21) Printer control board (PRCB)

584

Field Service Ver3.0 Nov.2006 Classification Main body Fan abnormality Code Causes Resulting operation SC32-27 The rotation of the paper feed assist fan /Fr2 (FM22) is checked, and the 24V power source is also checked. An abnormal condition occurs with the FM22 EM signal a specified period of time after FM22 is turned ON. This abnormal condition recurs even a specified period of time after FM22 is turned OFF and then turned ON, and an error detection signal (24V cut off) is detected. SC32-28 The blowout of a fuse for the paper feed assist fan /Fr2 (FM22) in the printer control board (PRCB) is checked. An abnormal condition occurs with the FM22 EM signal a specified period of time after FM22 is turned ON. This abnormal condition recurs even a specified period of time after FM22 is turned OFF and then turned ON, and an error detection signal (blowout of a fuse) is detected. SC32-29 The rotation of the paper feed assist fan /Fr2 (FM22) is checked. An abnormal condition occurs with the FM22 EM signal a specified period of time after FM22 is turned ON. This abnormal condition recurs even a specified period of time after FM22 is turned OFF and then turned ON, and an error detection signal (24V cut off/blowout of a fuse) is not detected. The main body stops immediately to turn OFF the RL1 (main).

14. MALFUNCTION CODE Estimated abnormal parts DC power supply /1 (DCPS/ 1)

Paper feed assist fan /Fr2 (FM22) Printer control board (PRCB)

Paper feed assist fan /Fr2 (FM22) Printer control board (PRCB)

585

bizhub PRO 1050/1050P 1050e/1050eP

14. MALFUNCTION CODE

Field Service Ver3.0 Nov.2006 Causes Resulting operation The main body stops immediately to turn OFF the RL1 (main). Estimated abnormal parts DC power supply /1 (DCPS/ 1)

bizhub PRO 1050/1050P /1050e/1050eP

Classification Main body Fan abnormality

Code

SC32-30 The rotation of the paper feed assist fan /Rr2 (FM23) is checked, and the 24V power source is also checked. An abnormal condition occurs with the FM23 EM signal a specified period of time after FM23 is turned ON. This abnormal condition recurs even a specified period of time after FM23 is turned OFF and then turned ON, and an error detection signal (24V cut off) is detected. SC32-31 The blowout of a fuse for the paper feed assist fan /Rr2 (FM23) in the printer control board (PRCB) is checked. An abnormal condition occurs with the FM23 EM signal a specified period of time after FM23 is turned ON. This abnormal condition recurs even a specified period of time after FM23 is turned OFF and then turned ON, and an error detection signal (blowout of a fuse) is detected with the 24V normal. SC32-32 The rotation of the paper feed assist fan /Rr2 (FM23) is checked. An abnormal condition occurs with the FM23 EM signal a specified period of time after FM23 is turned ON. This abnormal condition recurs even a specified period of time after FM23 is turned OFF and then turned ON, and an error detection signal (24V cut off/blowout of a fuse) is not detected.

Paper feed assist fan /Rr2 (FM23) Printer control board (PRCB)

Paper feed assist fan /Rr2 (FM23) Printer control board (PRCB)

586

Field Service Ver3.0 Nov.2006 Classification PF Fan abnormality Code Causes Resulting operation SC32-33 The rotation of the paper feed assist fan /Fr1 (FM41) is checked, and the 24V power source is also checked. An abnormal condition occurs with the FM41 EM signal a specified period of time after FM41 is turned ON. This abnormal condition recurs even a specified period of time after FM41 is turned OFF and then turned ON, and an error detection signal (24V cut off) is detected. SC32-34 The blowout of a fuse for the paper feed assist fan /Fr1 (FM41) in the printer control board (PRCB) is checked. An abnormal condition occurs with the FM41 EM signal a specified period of time after FM41 is turned ON. This abnormal condition recurs even a specified period of time after FM41 is turned OFF and then turned ON, and an error detection signal (blowout of a fuse) is detected with the 24V normal. SC32-35 The rotation of the paper feed assist fan /Fr1 (FM41) is checked. An abnormal condition occurs with the FM41 EM signal a specified period of time after FM41 is turned ON. This abnormal condition recurs even a specified period of time after FM41 is turned OFF and then turned ON, and an error detection signal (24V cut off/blowout of a fuse) is not detected. The main body stops immediately to turn OFF the RL1 (main).

14. MALFUNCTION CODE Estimated abnormal parts DC power supply /2 (DCPS/ 2)

Paper feed assist fan /Fr1 (FM41) PF drive board (PFUDB)

Paper feed assist fan /Fr1 (FM41) PF drive board (PFUDB)

587

bizhub PRO 1050/1050P 1050e/1050eP

14. MALFUNCTION CODE

Field Service Ver3.0 Nov.2006 Causes Resulting operation The main body stops immediately to turn OFF the RL1 (main). Estimated abnormal parts DC power supply /2 (DCPS/ 2)

bizhub PRO 1050/1050P /1050e/1050eP

Classification PF Fan abnormality

Code

SC32-36 The rotation of the paper feed assist fan /Rr1 (FM42) is checked, and the 24V power source is also checked. An abnormal condition occurs with the FM42 EM signal a specified period of time after FM42 is turned ON. This abnormal condition recurs even a specified period of time after FM42 is turned OFF and then turned ON, and an error detection signal (24V cut off) is detected. SC32-37 The blowout of a fuse for the paper feed assist fan /Rr1 (FM42) in the printer control board (PRCB) is checked. An abnormal condition occurs with the FM42 EM signal a specified period of time after FM42 is turned ON. This abnormal condition recurs even a specified period of time after FM42 is turned OFF and then turned ON, and an error detection signal (blowout of a fuse) is detected with the 24V normal. SC32-38 The rotation of the paper feed assist fan /Rr1 (FM42) is checked. An abnormal condition occurs with the FM42 EM signal a specified period of time after FM42 is turned ON. This abnormal condition recurs even a specified period of time after FM42 is turned OFF and then turned ON, and an error detection signal (24V cut off/blowout of a fuse) is not detected.

Paper feed assist fan /Rr1 (FM42) PF drive board (PFUDB)

Paper feed assist fan /Rr1 (FM42) PF drive board (PFUDB)

588

Field Service Ver3.0 Nov.2006 Classification PF Fan abnormality Code Causes Resulting operation SC32-39 The rotation of the paper feed assist fan /Fr2 (FM43) is checked, and the 24V power source is also checked. An abnormal condition occurs with the FM43 EM signal a specified period of time after FM43 is turned ON. This abnormal condition recurs even a specified period of time after FM43 is turned OFF and then turned ON, and an error detection signal (24V cut off) is detected. SC32-40 The blowout of a fuse for the paper feed assist fan /Fr2 (FM43) in the printer control board (PRCB) is checked. An abnormal condition occurs with the FM43 EM signal a specified period of time after FM43 is turned ON. This abnormal condition recurs even a specified period of time after FM43 is turned OFF and then turned ON, and an error detection signal (blowout of a fuse) is detected with the 24V normal. SC32-41 The rotation of the paper feed assist fan /Fr2 (FM43) is checked. An abnormal condition occurs with the FM43 EM signal a specified period of time after FM43 is turned ON. This abnormal condition recurs even a specified period of time after FM43 is turned OFF and then turned ON, and an error detection signal (24V cut off/blowout of a fuse) is not detected. The main body stops immediately to turn OFF the RL1 (main).

14. MALFUNCTION CODE Estimated abnormal parts DC power supply /2 (DCPS/ 2)

Paper feed assist fan /Fr2 (FM43) PF drive board (PFUDB)

Paper feed assist fan /Fr2 (FM43) PF drive board (PFUDB)

589

bizhub PRO 1050/1050P 1050e/1050eP

14. MALFUNCTION CODE

Field Service Ver3.0 Nov.2006 Causes Resulting operation The main body stops immediately to turn OFF the RL1 (main). Estimated abnormal parts DC power supply /2 (DCPS/ 2)

bizhub PRO 1050/1050P /1050e/1050eP

Classification PF Fan abnormality

Code

SC32-42 The rotation of the paper feed assist fan /Rr2 (FM44) is checked, and the 24V power source is also checked. An abnormal condition occurs with the FM44 EM signal a specified period of time after FM44 is turned ON. This abnormal condition recurs even a specified period of time after FM44 is turned OFF and then turned ON, and an error detection signal (24V cut off) is detected. SC32-43 The blowout of a fuse for the paper feed assist fan /Rr2 (FM44) in the printer control board (PRCB) is checked. An abnormal condition occurs with the FM44 EM signal a specified period of time after FM44 is turned ON. This abnormal condition recurs even a specified period of time after FM44 is turned OFF and then turned ON, and an error detection signal (blowout of a fuse) is detected with the 24V normal. SC32-44 The rotation of the paper feed assist fan /Rr2 (FM44) is checked. An abnormal condition occurs with the FM44 EM signal a specified period of time after FM44 is turned ON. This abnormal condition recurs even a specified period of time after FM44 is turned OFF and then turned ON, and an error detection signal (24V cut off/blowout of a fuse) is not detected.

Paper feed assist fan /Rr2 (FM44) PF drive board (PFUDB)

Paper feed assist fan /Rr2 (FM44) PF drive board (PFUDB)

590

Field Service Ver3.0 Nov.2006 Classification PF Fan abnormality Code Causes Resulting operation SC32-45 The rotation of the paper feed assist fan /Fr3 (FM45) is checked, and the 24V power source is also checked. An abnormal condition occurs with the FM45 EM signal a specified period of time after FM45 is turned ON. This abnormal condition recurs even a specified period of time after FM45 is turned OFF and then turned ON, and an error detection signal (24V cut off) is detected. SC32-46 The blowout of a fuse for the paper feed assist fan /Fr3 (FM45) in the printer control board (PRCB) is checked. An abnormal condition occurs with the FM45 EM signal a specified period of time after FM45 is turned ON. This abnormal condition recurs even a specified period of time after FM45 is turned OFF and then turned ON, and an error detection signal (blowout of a fuse) is detected with the 24V normal. SC32-47 The rotation of the paper feed assist fan /Fr3 (FM45) is checked. An abnormal condition occurs with the FM45 EM signal a specified period of time after FM45 is turned ON. This abnormal condition recurs even a specified period of time after FM45 is turned OFF and then turned ON, and no error detection signal (24V cut off/blowout of a fuse) is detected. The main body stops immediately to turn OFF the RL1 (main).

14. MALFUNCTION CODE Estimated abnormal parts DC power supply /2 (DCPS/ 2)

Paper feed assist fan /Fr3 (FM45) PF drive board (PFUDB)

Paper feed assist fan /Fr3 (FM45) PF drive board (PFUDB)

591

bizhub PRO 1050/1050P 1050e/1050eP

14. MALFUNCTION CODE

Field Service Ver3.0 Nov.2006 Causes Resulting operation The main body stops immediately to turn OFF the RL1 (main). Estimated abnormal parts DC power supply /2 (DCPS/ 2)

bizhub PRO 1050/1050P /1050e/1050eP

Classification PF Fan abnormality

Code

SC32-48 The rotation of the paper feed assist fan /Rr3 (FM46) is checked, and the 24V power source is also checked. An abnormal condition occurs with the FM46 EM signal a specified period of time after FM46 is turned ON. This abnormal condition recurs even a specified period of time after FM46 is turned OFF and then turned ON, and an error detection signal (24V cut off) is detected. SC32-49 The blowout of a fuse for the paper feed assist fan /Rr3 (FM46) in the printer control board (PRCB) is checked. An abnormal condition occurs with the FM46 EM signal a specified period of time after FM46 is turned ON. This abnormal condition recurs even a specified period of time after FM46 is turned OFF and then turned ON, and an error detection signal (blowout of a fuse) is detected with the 24V normal. SC32-50 The rotation of the paper feed assist fan /Rr3 (FM46) is checked. An abnormal condition occurs with the FM46 EM signal a specified period of time after FM46 is turned ON. This abnormal condition recurs even a specified period of time after FM46 is turned OFF and then turned ON, and an error detection signal (24V cut off/blowout of a fuse) is not detected.

Paper feed assist fan /Rr3 (FM46) PF drive board (PFUDB)

Paper feed assist fan /Rr3 (FM46) PF drive board (PFUDB)

592

Field Service Ver3.0 Nov.2006 Classification PF Fan abnormality Code Causes Resulting operation SC32-51 The rotation of the cooling fan (FM20) is checked, and the 24V power source is also checked. An abnormal condition occurs with the FM46 EM signal a specified period of time after FM46 is turned ON. This abnormal condition recurs even a specified period of time after FM46 is turned OFF and then turned ON, and an error detection signal (24V cut off) is detected. SC32-52 The blowout of a fuse for the cooling fan (FM20) in the printer control board (PRCB) is checked. An abnormal condition occurs with the FM46 EM signal a specified period of time after FM46 is turned ON. This abnormal condition recurs even a specified period of time after FM46 is turned OFF and then turned ON, and an error detection signal (blowout of a fuse) is detected with the 24V normal. Main body SC32-53 The rotation of the cooling fan (FM20) is checked. An abnormal condition occurs with the FM46 EM signal a specified period of time after FM46 is turned ON. This abnormal condition recurs even a specified period of time after FM46 is turned OFF and then turned ON, and an error detection signal (24V cut off/blowout of a fuse) is not detected. The main body stops immediately to turn OFF the RL1 (main).

14. MALFUNCTION CODE Estimated abnormal parts DC power supply /2 (DCPS/ 2)

Cooling fan (FM20) PF drive board (PFUDB)

593

bizhub PRO 1050/1050P 1050e/1050eP

14. MALFUNCTION CODE

Field Service Ver3.0 Nov.2006 Causes Resulting operation The main body stops immediately to turn OFF the RL1 (main). Estimated abnormal parts DC power supply /2 (DCPS/ 2)

bizhub PRO 1050/1050P /1050e/1050eP

Classification Main body Fan abnormality

Code

SC32-54 The rotation of the power supply cooling fan /3 (FM27) is checked. An abnormal condition occurs with the FM27 EM signal a specified period of time after FM27 is turned ON. This abnormal condition recurs even a specified period of time after FM27 is turned OFF and then turned ON, and no error detection signal (24V cut off/blowout of a fuse) is detected. SC32-55 The EM signal of the power supply cooling fan /3 (FM27) is ON when starting the print.

Error code is not displayed on the operation panel, but displayed only on the data collection, the list output and the CSRC. The control of the main body is made by using a data previously obtained.

ADU section motor abnormality

SC33-01 The blowout of a fuse for the motor of the registration section in the ADU drive board /2 (ADUDB2) is checked. An error detection signal (blowout of a fuse) of the ADU conveyance motor /2 (M16)/ registration motor (M17)/loop motor (M18) is detected after the print is started. At this time, the closing of the door detection/PFU door is detected 10 times in succession.

The main body stops immediately to turn OFF the RL1 (main).

ADU drive board /2 (ADUDB2) ADU conveyance motor /2 (M16) Registration motor (M17) Loop motor (M18)

594

Field Service Ver3.0 Nov.2006 Classification Main body ADU section motor abnormality Code Causes Resulting operation SC33-02 The blowout of a fuse for the ADU motor in the ADU drive board /1 (ADUDB1) is checked. An error detection signal (blowout of a fuse) of the reverse/exit motor (M13)/ADU acceleration motor (M14)/ ADU conveyance motor /1 (M15)/ADU reverse motor (M12) is detected after the print is started. At this time, the closing of the door detection/PFU door is detected 10 times in succession. SC33-04 The blowout of a fuse for the transfer assist motor (M19) in the printer control board (PRCB) is checked. When M19 turns ON from OFF, an error detection signal (blowout of a fuse) is detected. At this time, the closing of the door is detected 10 times in succession. SC33-05 The blowout of a fuse for the web motor (M24) in the printer control board (PRCB) is checked, and the 24V power source is also checked. When M24 turn ON from OFF, error detection signals (blowout of a fuse and the 24V cut off) are detected. SC33-06 The blowout of a fuse for the web motor (M24) in the printer control board (PRCB) is checked. When M24 turns ON from OFF, an error detection signal (blowout of a fuse) is detected. At this time, an error detection signal (24V cut off) is not detected. The main body stops immediately to turn OFF the RL1 (main).

14. MALFUNCTION CODE Estimated abnormal parts ADU drive board /1 (ADUDB1) Reverse/exit motor (M13) ADU accelerate motor (M14) ADU conveyance motor /1 (M15) ADU reverse motor (M12)

Printer control board (PRCB) Transfer assist motor (M19)

DC power supply /2 (DCPS/ 2)

Printer control board (PRCB) Web motor (M24)

595

bizhub PRO 1050/1050P 1050e/1050eP

14. MALFUNCTION CODE

Field Service Ver3.0 Nov.2006 Causes Resulting operation The main body stops immediately to turn OFF the RL1 (main). Estimated abnormal parts Printer control board (PRCB) AC drive board (ACDB) Fusing heater lamp /1 (L2) Fusing heater lamp /2 (L3) Fusing heater lamp /3 (L4) Thermistor /1 (TH1) Thermistor /2 (TH2) Thermistor /3 (TH3) Thermistor /4 (TH4) Caution: When SC34-**, SC35** or SC36-** (fusing temperature be sure to related repair abnormalities) occur, defective parts before setting the software DIPSW3-1 to 0. Setting the DIPSW3-1 to 0 with defective parts not repaired may result in a fire.

bizhub PRO 1050/1050P /1050e/1050eP

Classification Main body Fusing high temperature abnormality

Code

SC34-01 Thermistor /1 (TH1) high temperature detection (software). TH1 detects a temperature of 210C or above 5 times in a period of 1 second. SC34-02 Thermistor /3 (TH3) high temperature detection (software). TH3 detects a temperature of 230C or above 5 times in a period of 1 second. SC34-03 Thermistor /1 (TH1) high temperature detection (hardware). An abnormal condition is detected with the fusing error detection signal 1. SC34-04 Thermistor /3 (TH3) high temperature detection (hardware). An abnormal condition is detected with the fusing error detection signal 4.

Fusing low temperature abnormality

SC35-01 Thermistor /1 (TH1) low temperature detection (software). TH1 does not get to 50C when a specified period of time elapses after the main switch (SW1) is turned ON for the fusing ON control. SC35-02 Thermistor /3 (TH3) low temperature detection (software). TH3 does not get to 50C when a specified period of time elapses after the main switch (SW1) is turned ON for the fusing ON control.

Fusing sensor abnormality

SC36-01 Thermistor /1 (TH1) high temperature detection (long time/software). TH1 detects a temperature of 200C or above 30 times in a row in a period of 1 second. SC36-02 Thermistor /3 (TH3) high temperature detection (long time/software). TH3 detects a temperature of 220C or above 30 times in a row in a period of 1 second.

596

Field Service Ver3.0 Nov.2006 Classification Main body Fusing sensor abnormality Code Causes Resulting operation SC36-03 Thermistor /1 (TH1) low temperature detection (hardware). TH1 detects an abnormal condition with the fusing error detection signal 2. SC36-04 Thermistor /1 (TH1) low temperature detection (hardware). TH3 detects an abnormal condition with the fusing error detection signal 5. SC36-05 Thermistor /3 (TH3) low temperature detection (hardware). TH1 detects an abnormal condition with the fusing error detection signal 3. SC36-06 Thermistor /3 (TH3) low temperature detection (hardware). TH3 detects an abnormal condition with the fusing error detection signal 6. The main body stops immediately to turn OFF the RL1 (main).

14. MALFUNCTION CODE Estimated abnormal parts Printer control board (PRCB) AC drive board (ACDB) Fusing heater lamp /1 (L2) Fusing heater lamp /2 (L3) Fusing heater lamp /3 (L4) Thermistor /1 (TH1) Thermistor /2 (TH2) Thermistor /3 (TH3) Thermistor /4 (TH4) Caution: When SC34-**, SC35** or SC36-** (fusing temperature be sure to related repair abnormalities) occur, defective parts before setting the software DIPSW3-1 to 0. Setting the DIPSW3-1 to 0 with defective parts not repaired may result in a fire.

Scanner abnormality

SC41-01 It is checked that the movement time for the scanner motor (M27) is over, and the 24V power source is also checked. The scanner home sensor (PS51) or the APS sensor /1 (PS52) does not turn ON within a specified period of time after the home position search is started. And an error detection signal (24V cut off) is detected with the scanner motor (M27). SC41-02 The blowout of a fuse for the scanner motor (M27) in the scanner drive board (SDB) is checked. The scanner home sensor (PS51) or the APS sensor /1 (PS52) does not turn ON within a specified period of time after the home position search is started. And an error detection signal (blowout of a fuse) is detected with M27. At this time, an error detection signal (24V cut off) is not detected with the M27.

DC power supply /1 (DCPS/ 1)

Scanner drive board (SDB) Scanner motor (M27)

597

bizhub PRO 1050/1050P 1050e/1050eP

14. MALFUNCTION CODE

Field Service Ver3.0 Nov.2006 Causes Resulting operation The main body stops immediately to turn OFF the RL1 (main). Estimated abnormal parts Scanner drive board (SDB) Scanner motor (M27) Scanner home sensor (PS51)

bizhub PRO 1050/1050P /1050e/1050eP

Classification Main body Scanner abnormality

Code

SC41-03 The time for the movement of the scanner motor (M27) is over. The scanner home sensor (PS51) or the APS sensor /1 (PS52) does not turn ON within a specified period of time after the home position search is started. And an error detection signal (blowout of a fuse/24V cut off) is not detected with the M27.

Write abnormality

SC41-10 The abnormal speed of the polygon motor (M21) is checked, and the 24V power source is also checked. When switching the speed of M21, the lock signal of M21 is not detected within a specified period of time after the switchover is started, and an error detection signal (24V cut off) is detected. SC41-11 The abnormal speed of the polygon motor (M21) is checked. When switching the speed of M21, the lock signal of M21 is not detected within a specified period of time after the switchover is started.

DC power supply /1 (DCPS/ 1)

Polygon motor (M21) Printer control board (PRCB)

Fan abnormality

SC42-01 The rotation of the scanner cooling fan (FM19) is checked, and 24V power source is also checked. An abnormal condition occurs with the FM19 EM signal a specified period of time after FM19 turns ON. This abnormal condition recurs even a specified period of time after FM19 is turned OFF and then turned ON, and an error detection signal (24V cut off) is detected.

DC power supply /2 (DCPS/ 2)

598

Field Service Ver3.0 Nov.2006 Classification Main body Fan abnormality Code Causes Resulting operation SC42-02 The blowout of a fuse for the scanner cooling fan (FM19) in the scanner drive board (SDB) is checked. An abnormal condition occurs with the FM19 EM signal a specified period of time after FM19 turns ON. This abnormal condition recurs even a specified period of time after FM19 is turned OFF and then turned ON, and an error detection signal (blowout of a fuse) is detected. At this time, an error detection signal (24V cut off) is not detected. SC42-03 The rotation of the scanner cooling fan (FM19) is checked. An abnormal condition occurs with the FM19 EM signal a specified period of time after FM19 turns ON. This abnormal condition recurs even a specified period of time after FM19 is turned OFF and then turned ON, and an error detection signal (24V cut off/blowout of a fuse) is not detected. SC42-04 The rotation of the suction fan /1 (FM6) is checked, and 24V power source is also checked. An abnormal condition occurs with the FM6 EM signal a specified period of time after FM6 turns ON. This abnormal condition recurs even a specified period of time after FM6 is turned OFF and then turned ON, and an error detection signal (24V cut off) is detected. The main body stops immediately to turn OFF the RL1 (main).

14. MALFUNCTION CODE Estimated abnormal parts Scanner drive board (SDB) Scanner cooling fan (FM19)

Scanner cooling fan (FM19)

DC power supply /2 (DCPS/ 2)

599

bizhub PRO 1050/1050P 1050e/1050eP

14. MALFUNCTION CODE

Field Service Ver3.0 Nov.2006 Causes Resulting operation The main body stops immediately to turn OFF the RL1 (main). Estimated abnormal parts AC drive board (ACDB) Suction fan /1 (FM6)

bizhub PRO 1050/1050P /1050e/1050eP

Classification Main body Fan abnormality

Code

SC42-05 The blowout of a fuse for the suction fan /1 (FM6) in the AC drive board (ACDB) is checked. An abnormal condition occurs with the FM6 EM signal a specified period of time after FM6 turns ON. This abnormal condition recurs even a specified period of time after FM6 is turned OFF and then turned ON, and an error detection signal (blowout of a fuse) is detected. At this time, an error detection signal (24V cut off) is not detected. SC42-06 The rotation of the suction fan /1 (FM6) is checked. An abnormal condition occurs with the FM6 EM signal a specified period of time after FM6 turns ON. This abnormal condition recurs even a specified period of time after FM6 is turned OFF and then turned ON, and an error detection signal (24V cut off/blowout of a fuse) is not detected. SC42-07 The EM signal of the suction fan /1 (FM6) is ON when the printing is started. SC42-08 The rotation of the suction fans /2 (FM7) and /3 (FM8) is checked, and the 24V power source is also checked. An abnormal condition occurs with the FM7/FM8 EM signal a specified period of time after FM7/FM8 turns ON. This abnormal condition recurs even a specified period of time after FM7/FM8 is turned OFF and then turned ON, and an error detection signal (24V cut off) is detected.

Suction fan /1 (FM6)

DC power supply /2 (DCPS/ 2)

600

Field Service Ver3.0 Nov.2006 Classification Main body Fan abnormality Code Causes Resulting operation SC42-09 The blowout of a fuse for the suction fans /2 (FM7) and /3 (FM8) in the AC drive board (ACDB) is checked. An abnormal condition occurs with the FM7/FM8 EM signal a specified period of time after FM7/FM8 turns ON. This abnormal condition recurs even a specified period of time after FM7/FM8 is turned OFF and then turned ON, and an error detection signal (blowout of a fuse) is detected. At this time an error detection signal (24V cut off) is not detected. SC42-10 The rotation of the suction fans /2 (FM7) and /3 (FM8) is checked. An abnormal condition occurs with the FM7/FM8 EM signal a specified period of time after FM7/FM8 turns ON. This abnormal condition recurs even a specified period of time after FM7/FM8 is turned OFF and then turned ON, and an error detection signal (24V cut off/blowout of a fuse) is not detected. SC42-16 The rotation of the polygon cooling fan (FM18) is checked, and the 24V power source is also checked. An abnormal condition occurs with the FM18 EM signal a specified period of time after FM18 turns ON. This abnormal condition recurs even a specified period of time after FM18 is turned OFF and then turned ON, and an error detection signal (24V cut off) is detected. The main body stops immediately to turn OFF the RL1 (main).

14. MALFUNCTION CODE Estimated abnormal parts AC drive board (ACDB) Suction fan /2 (FM7) Suction fan /3 (FM8)

DC power supply /2 (DCPS/ 2)

601

bizhub PRO 1050/1050P 1050e/1050eP

14. MALFUNCTION CODE

Field Service Ver3.0 Nov.2006 Causes Resulting operation The main body stops immediately to turn OFF the RL1 (main). Estimated abnormal parts AC drive board (ACDB) Polygon cooling fan (FM18)

bizhub PRO 1050/1050P /1050e/1050eP

Classification Main body Fan abnormality

Code

SC42-17 The blowout of a fuse for the polygon cooling fans (FM18) in the AC drive board (ACDB) is checked. An abnormal condition occurs with the FM18 EM signal a specified period of time after FM18 turns ON. This abnormal condition recurs even a specified period of time after FM18 is turned OFF and then turned ON, and an error detection signal (blowout of a fuse) is detected. At this time, an error detection signal (24V cut off) is not detected. SC42-18 Rotation of the polygon cooling fans (FM18) is checked. An abnormal condition occurs with the FM18 EM signal a specified period of time after FM18 turns ON. This abnormal condition recurs even a specified period of time after FM18 is turned OFF and then turned ON, and an error detection signal (24V cut off/blowout of a fuse) is not detected. SC42-19 The EM signal of the polygon cooling fan (FM18) is ON when the printing is started.

Error code is not displayed on the operation panel, but displayed only on the data collection, the list output and the CSRC. The control of the main body is made by using a data previously obtained.

Polygon cooling fan (FM18)

602

Field Service Ver3.0 Nov.2006 Classification Main body Image processing abnormality Code Causes Resulting operation SC46-01* APC abnormality. While in the image write, APC is not applicable for the correction of the sub scan beam. Due to the 12V DC power for the laser drive not supplied, the MPC being wrong and the laser defective, the laser does not light up. Also, due to the rotation of the polygon mirror unavailable, the displacement of the index sensor, and the index sensor being defective, the index sensor cannot detect the laser. SC46-02* Scanner FIFO abnormality. FIFO address abnormality for the scanner. While in the image read, the compression of image data that is read in is not correctly terminated. SC46-03* FIFO address abnormality for the printer. While in the image write, the expansion processing of image data that is read in is not correctly terminated. SC46-05* Compression input FIFO abnormality. An error interrupt occurs with the compression/expansion chip FIFO. SC46-06* Elongation abnormality. Due to the elongation of data the compression of which is not completed, the destruction of the compressed data and the abnormal length of data, an elongation abnormality is detected. SC46-08* Index sensor abnormality. While in the execution of APC, no change is found in the output of the index sensor. SC46-12* SVV length abnormality. After negation of SVV, the compression of images that are read in and their development into the page memory are not terminated within a specified period of time. If there is a copy being made, the main body completes the paper exit before stopping operations. Turn OFF the RL1 (main).

14. MALFUNCTION CODE Estimated abnormal parts Write unit Power connector of the image processing board (IPB)

Image processing board (IPB)

Write unit Power connector of the image processing board (IPB) Image processing board (IPB)

603

bizhub PRO 1050/1050P 1050e/1050eP

14. MALFUNCTION CODE

Field Service Ver3.0 Nov.2006 Causes Resulting operation If there is a copy being made, the main body completes the paper exit before stopping operations. Turn OFF the RL1 (main). Estimated abnormal parts Image processing board (IPB) ADF Printer control board (PRCB)

bizhub PRO 1050/1050P /1050e/1050eP

Classification Main body Image processing abnormality

Code

SC46-13* Scanner time out. While in the image read, the compression processing from the scanner into the memory does not terminate within a specified period of time. The development from the scanner into the page memory does not terminate within a specified period of time. The SVV is not detected within a specified period of time. SC46-14* Printer time out. While in the image write, the expansion processing from the memory to the printer does not terminate within a specified period of time. The output from the page memory to the printer does not terminate within a specified period of time. The PVV is not detected within a specified period of time. SC46-15* Expansion device access abnormality. While in the image write, despite of no resource provided, an inappropriate processing such as accessing to the elongation device is made. SC46-16* Compression device access abnormality. When writing images, in spite of no resource provided, an inappropriate processing such as an access to the compression device is made. SC46-17* Filter coefficient abnormality. When processing images, a filter coefficient cannot be created normally. SC46-19* When accessing to the memory device, a defective software is detected.

Image processing board (IPB) Printer control board (PRCB)

Image processing board (IPB) Image processing program

604

Field Service Ver3.0 Nov.2006 Classification Main body Image processing abnormality Code Causes Resulting operation SC46-21* Memory time out. The expansion processing from the memory to the pate memory is not terminated within a specified period of time. The compression processing from the page memory to the memory is not terminated within a specified period of time. The development from the memory into the page memory is not terminated within a specified period of time. The transmission of the compressed data from memory to memory is not terminated within a specified period of time. SC46-23* SVV off abnormality. While in the image read, SVV does not turn OFF within a specified period of time and the preparation for scanning the next page cannot be started. SC46-24* Shading correction abnormality (GA abnormality). SC46-25* AOC/AGC adjustment level abnormality. The light blocking cover at the read section and the lens cover are removed. The connector of the A/D converter board is disconnected. The power cable of the A/D converter board is unplugged. The IC protector of the A/D converter board is cut off. The light volume of the exposure lamp is excessive. The exposure lamp does not light up. If there is a copy being made, the main body completes the paper exit before stopping operations. Turn OFF the RL1 (main).

14. MALFUNCTION CODE Estimated abnormal parts Image processing board (IPB) Image processing program Printer control board (PRCB)

Image processing board (IPB)

Image processing board (IPB) Image processing program

605

bizhub PRO 1050/1050P 1050e/1050eP

14. MALFUNCTION CODE

Field Service Ver3.0 Nov.2006 Causes Resulting operation Error code is not displayed on the operation panel, but displayed only on the data collection, the list output and the CSRC. The control of the main body is made by using a data previously obtained. Estimated abnormal parts Image processing board (IPB)

bizhub PRO 1050/1050P /1050e/1050eP

Classification Main body Image processing abnormality

Code

SC46-26 The adjustment data evacuated by resolutions is not available.

SC46-27 A density conversion gamma curve cannot be created normally.

SC46-31* Despite of the MPC not being terminated, the initial sampling of the APC is attempted. SC46-32* While executing the APC, the execution of the MPC is attempted. SC46-35* Sequentially shot page area abnormality. Due to an image area abnormality on the memory, images cannot be developed on the memory. SC46-36* Initial APC timing abnormality. The PVV is turned ON before the initial APC start processing is completed. SC46-40 Hard disk initialization abnormality. The hard disk is defective, or the connector is poorly connected. (1050,1050e only) SC46-41 The JOB information cannot be stored on the hard disk. (1050,1050e only) SC46-42 While in a periodical cleaning, opening the rote to hard disk is not succeed. (1050,1050e only) SC46-43 Hard disk access defective. The hard disk is defective or the connector is connected improperly. (1050,1050e only) SC46-50 Communication error is detected during tandem operation. SC46-51 Communication error is detected during tandem image transmission.

If there is a copy being made, the main body completes the paper exit before stopping operations. Turn OFF the RL1 (main).

Image processing board (IPB) Image processing program

Write section Printer control program Image processing program The main body stops immediately to turn OFF the RL1 (main). Image processing board (IPB) Image processing program Hard disk /1 (HDD1)

Image processing board (IPB) Image processing program

606

Field Service Ver3.0 Nov.2006 Classification Main body Image processing abnormality Code Causes Resulting operation SC46-61 The scan operation starts before the original skew adjustment is terminated. (The skew adjustment is too late.) SC46-62 The print operation starts before the paper mis-centering adjustment is terminated. (The mis-centering adjustment is too late.) SC46-63 The AGC is retried due to the decreased light volume of the exposure lamp. However, no error occurs. SC46-64 A PWM gamma curve is not created properly. SC46-66 Shift amount abnormality while in the repeat (when the width is specified, or in the auto mode). When the shift amount while in the repeat is negative (-). SC46-80* The message queue is insufficient or destroyed. SC46-81* The parameter value is in excess of the permissible limits. SC46-82* The ID of the task that sends the message queue is undefined. SC46-83* The receiving event of the message is undefined. SC46-90* Memory access abnormality. SC46-91* Header readout address abnormality. SC46-99* DIMM memory abnormality. An error is detected in the DIMM memory check at the start. IC Controller abnormality SC49-01 Printer controller initial communication abnormality SC49-03 Transfer error to the main body image memory SC49-04 Hard disc /2 (HDD2) abnormality SC49-05 IC cooling fan (FM24) lock abnormality SC49-06 Unregulations IP error. SC49-07 The CF version is different from the version information in the hard disc /2 (HDD2). The main body stops immediately to turn OFF the RL1 (main). If there is a copy being made, the main body completes the paper exit before stopping operations. Turn OFF the RL1 (main). Error code is not displayed on the operation panel, but displayed only on the data collection, the list output and the CSRC. The control of the main body is made by using a data previously obtained.

14. MALFUNCTION CODE Estimated abnormal parts ADF Original skew sensor /Fr (PS312), /Rr (PS311) Centering sensor (PS54)

Exposure lamp (L1)

Toner control sensor board (TCSB)

Image processing program Image processing board (IPB)

IC board (ICB) Hard disk /2 (HDD2) IC board (ICB) IC board (ICB) Hard disk /2 (HDD2) IC board (ICB)

Hard disk /2 (HDD2) format HDD2

607

bizhub PRO 1050/1050P 1050e/1050eP

14. MALFUNCTION CODE

Field Service Ver3.0 Nov.2006 Causes Resulting operation The main body stops immediately to turn OFF the RL1 (main). Estimated abnormal parts Hard disk /2 (HDD2) format HDD2

bizhub PRO 1050/1050P /1050e/1050eP

Classification Main body IC Controller abnormality

Code

SC49-08 While in the security ON, the unlock of the HDD results in a failure due to the mismatched password of the hard disk /2 (HDD2). SC49-09 Unlocked hard disk/2 (HDD2) is detected when security turns ON. SC49-10 An unformatted hard disc /2 (HDD2) is detected.

Drive abnormality

SC50-01* Main body drive serial input abnormality 1. In the I/O initial communication check in the printer control board (PRCB) from the power on ACK, a serial data is not received from the main body drive unit within a specified period of time. SC50-02* Main body drive serial input abnormality 2. In the I/O initial communication check in the printer control board (PRCB) from the power on ACK, a serial data is not received from the main body drive unit within a specified period of time. SC50-03* Main body drive serial input abnormality 3. In the I/O initial communication check in the printer control board (PRCB) from the power on ACK, a serial data is not received from the main body drive unit within a specified period of time. SC50-04* Main body drive serial input abnormality 4. In the I/O initial communication check in the printer control board (PRCB) from the power on ACK, a serial data is not received from the main body drive unit within a specified period of time.

Printer control board (PRCB) PF drive board (PFUDB) The connector between the PF and the main body.

Commu- SC50-05* Drive communication reception nication abnormality error detection abnormality. SC50-06* Drive communication reception error detection abnormality. SC50-07* Drive communication reception error detection abnormality. Printer control board (PRCB)

608

Field Service Ver3.0 Nov.2006 Classification Main body Code Causes Resulting operation Commu- SC50-08* Drive communication reception nication abnormality error detection abnormality. SC50-10 When the power switch is turned ON, the printer control board (PRCB) cannot receive initial data from the image processing board (IPB) within a specified period of time. SC50-11 Any of the following error is detected during data reception between image processing board (IPB) and printer control board (PRCB). Data head error Data checksum error Undefined command reception error Occurrence of communication GA error vector SC51-01* Drive communication reception error detection abnormality. SC51-02* Drive communication reception error detection abnormality. SC51-03* Drive communication reception error detection abnormality. Fan abnormality SC52-01 The rotation of the cooling fan /1 (FM1) is checked, and +24V power source is also checked. An abnormal condition occurs with the FM1 EM signal a specified period of time after FM1 turns ON. This abnormal condition recurs even a specified period of time after FM1 is turned OFF and then turned ON, and an error detection signal (24V cut off) is detected. The main body stops immediately to turn OFF the RL1 (main).

14. MALFUNCTION CODE Estimated abnormal parts Printer control board (PRCB) Printer control board (PRCB) Image processing board (IPB)

Printer control board (PRCB) Image processing board (IPB) The connector between the PRDB and the IPB.

Printer control board (PRCB) PF drive board (PFUDB) The connector between the PF and the main body.

DC power supply /2 (DCPS/ 2)

609

bizhub PRO 1050/1050P 1050e/1050eP

14. MALFUNCTION CODE

Field Service Ver3.0 Nov.2006 Causes Resulting operation The main body stops immediately to turn OFF the RL1 (main). Estimated abnormal parts AC drive board (ACDB) Cooling fan /1 (FM1) Printer control board (PRCB)

bizhub PRO 1050/1050P /1050e/1050eP

Classification Main body Fan abnormality

Code

SC52-02 The blowout of a fuse for the cooling fan /1 (FM1) in the AC drive board (ACDB) is checked. An abnormal condition occurs with the FM1 EM signal a specified period of time after FM1 turns ON. This abnormal condition recurs even a specified period of time after FM1 is turned OFF and then turned ON, and an error detection signal (blowout of a fuse) is detected. At this time, an error detection signal (24V cut off) is not detected. SC52-03 Rotation of the cooling fan /1 (FM1) is checked. An abnormal condition occurs with the FM1 EM signal a specified period of time after FM1 turns ON. This abnormal condition recurs even a specified period of time after FM1 is turned OFF and then turned ON, and an error detection signal (24V cut off/blowout of a fuse) is not detected. SC52-04 The rotation of the cooling fan /2 (FM2) is checked, and +24V power source is also checked. An abnormal condition occurs with the FM2 EM signal a specified period of time after FM2 turns ON. This abnormal condition recurs even a specified period of time after FM2 is turned OFF and then turned ON, and an error detection signal (24V cut off) is detected.

AC drive board (ACDB) Cooling fan /1 (FM1) Printer control board (PRCB)

DC power supply /2 (DCPS/ 2)

610

Field Service Ver3.0 Nov.2006 Classification Main body Fan abnormality Code Causes Resulting operation SC52-05 The blowout of a fuse for the cool- The main body ing fan /2 (FM2) in the AC drive board (ACDB) is checked. An abnormal condition occurs with the FM2 EM signal a specified period of time after FM2 turns ON. This abnormal condition recurs even a specified period of time after FM2 is turned OFF and then turned ON, and an error detection signal (blowout of a fuse) is detected. At this time, an error detection signal (24V cut off) is not detected. SC52-06 Rotation of the cooling fan /2 (FM2) is checked. An abnormal condition occurs with the FM2 EM signal a specified period of time after FM2 turns ON. This abnormal condition recurs even a specified period of time after FM2 is turned OFF and then turned ON, and an error detection signal (24V cut off/blowout of a fuse) is not detected. SC52-07 The rotation of the cooling fan /3 (FM3) is checked, and +24V power source is also checked. An abnormal condition occurs with the FM3 EM signal a specified period of time after FM3 turns ON. This abnormal condition recurs even a specified period of time after FM3 is turned OFF and then turned ON, and an error detection signal (24V cut off) is detected. stops immediately to turn OFF the RL1 (main).

14. MALFUNCTION CODE Estimated abnormal parts AC drive board (ACDB) Cooling fan /2 (FM2) Printer control board (PRCB)

AC drive board (ACDB) Cooling fan /2 (FM2) Printer control board (PRCB)

DC power supply /2 (DCPS/ 2)

611

bizhub PRO 1050/1050P 1050e/1050eP

14. MALFUNCTION CODE

Field Service Ver3.0 Nov.2006 Causes Resulting operation The main body stops immediately to turn OFF the RL1 (main). Estimated abnormal parts AC drive board (ACDB) Cooling fan /3 (FM3) Printer control board (PRCB)

bizhub PRO 1050/1050P /1050e/1050eP

Classification Main body Fan abnormality

Code

SC52-08 The blowout of a fuse for the cooling fan /3 (FM3) in the AC drive board (ACDB) is checked. An abnormal condition occurs with the FM3 EM signal a specified period of time after FM3 turns ON. This abnormal condition recurs even a specified period of time after FM3 is turned OFF and then turned ON, and an error detection signal (blowout of a fuse) is detected. At this time, an error detection signal (24V cut off) is not detected. SC52-09 Rotation of the cooling fan /3 (FM3) is checked. An abnormal condition occurs with the FM3 EM signal a specified period of time after FM3 turns ON. This abnormal condition recurs even a specified period of time after FM3 is turned OFF and then turned ON, and an error detection signal (24V cut off/blowout of a fuse) is not detected. SC52-10 The EM signal of the cooling fan /1 (FM1) is ON when the print is started. SC52-11 The EM signal of the cooling fan /2 (FM2) is ON when the print is started. SC52-12 The EM signal of the cooling fan /3 (FM3) is ON when the print is started.

AC drive board (ACDB) Cooling fan /3 (FM3) Printer control board (PRCB)

Error code is not displayed on the operation panel, but displayed only on the data collection, the list output and the CSRC. The control of the main body is made by using a data previously obtained.

Cooling fan /1 (FM1)

Cooling fan /2 (FM2)

Cooling fan /3 (FM3)

Power SC53-01 A speed error signal of the fusing abnormality motor (M1) is checked. An error detection signal is detected twice in succession a specified period of time after M1 turns ON. (The first signal is ignored.)

The main body stops immediately to turn OFF the RL1 (main).

Fusing motor (M1)

612

Field Service Ver3.0 Nov.2006 Classification Main body Code Causes Resulting operation Power SC53-02 The 24V power source for the total abnormality counter (CNT1) is checked. When CNT1 is turned ON from OFF, an error detection signal (blowout of a fuse/24V cut off) is detected. SC53-03 The blowout of a fuse for the total counter (CNT1) in the AC drive board (ACDB) is checked. When CNT1 is turned ON from OFF, an error detection signal (blowout of a fuse) is detected. However, an error detection signal (24V cut off) is not detected. SC53-04 The 24V power source for the key counter (CNT2) is checked. When CNT2 is turned ON from OFF, an error detection signal (blowout of a fuse/24V cut off) is detected. SC53-05 The blowout of a fuse for the key counter (CNT2) in the AC drive board (ACDB) is checked. When CNT2 is turned ON from OFF, an error detection signal (blowout of a fuse) is detected. However, an error detection signal (24V cut off) is not detected. SC53-06 The blowout of a 12V fuse for the AC drive board (ACDB) is checked. In the serial initial communication, a signal of the blowout of a 12V fuse (AC drive) is detected. SC53-07 The blowout of a 5V fuse for the AC drive board (ACDB) is checked. In the serial initial communication, a signal of the blowout of a 5V fuse (AC drive) is detected. SC53-08 The 12V power source in the printer control board (PRCB) is checked. An error detection signal of the 12V in PRCB is detected. The main body stops immediately to turn OFF the RL1 (main).

14. MALFUNCTION CODE Estimated abnormal parts DC power supply /2 (DCPS/ 2)

Main relay (RL1) Total counter (CNT1) AC drive board (ACDB)

DC power supply /2 (DCPS/ 2)

Key counter (CNT2)

AC drive board (ACDB)

DC power supply /1 (DCPS/ 1) Printer control board (PRCB)

613

bizhub PRO 1050/1050P 1050e/1050eP

14. MALFUNCTION CODE

Field Service Ver3.0 Nov.2006 Causes Resulting operation The main body stops immediately to turn OFF the RL1 (main). Estimated abnormal parts DC power supply /1 (DCPS/ 1)

bizhub PRO 1050/1050P /1050e/1050eP

Classification Main body

Code

Power SC53-11 The blowout of a SD/CL fuse in abnormality the tray is detected 1. The 24V power source for the SD/CL in the printer control board (PRCB) is checked. At the start, an error detection signal (blowout of a fuse for the solenoid/clutch) is detected, and an error detection signal (24V cut off) is also detected. SC53-12 The blowout of a SD/CL fuse in the tray is detected 2. The blowout of a fuse for the SD/CL in the printer control board (PRCB) is checked. At the start, an error detection signal (blowout of a fuse for the solenoid/clutch) is detected. However, an error detection signal (24V cut off) is not detected. SC53-13 The blowout of a fuse for SD/CL in the vertical conveyance is detected 1. The 24V power source for SD/CL in the printer control board (PRCB) is checked. At the start, an error detection signal (blowout of a fuse for the solenoid/clutch) is detected, and an error detection signal (24V cut off) is detected. SC53-14 The blowout of a fuse for SD/CL in the vertical conveyance is detected 2. The blowout of a fuse for SD/CL in the printer control board (PRCB) is checked. At the start, an error detection signal (blowout of a fuse for the solenoid/ clutch) is detected. However, an error detection signal (24V cut off) is not detected.

Paper feed clutch /1 (CL4), / 2 (CL6) Separation clutch /1 (CL5), / 2 (CL7) Printer control board (PRCB)

DC power supply /1 (DCPS/ 1)

Tray lock solenoid /1 (SD1), /2 (SD2), /3 (SD5) Drum claw solenoid (SD5) Pre-registration clutch /1 (CL1), /2 (CL3) Vertical conveyance clutch (CL2) Printer control board (PRCB)

614

Field Service Ver3.0 Nov.2006 Classification Main body Code Causes Resulting operation Power SC53-15 The blowout of a fuse for SD/CL in abnormality the PF is detected 1. The 24V power source for SD/CL in the PF drive board (PFUCB) is checked. At the start, an error detection signal (blowout of a fuse for the solenoid/clutch) is detected, and an error detection signal (24V cut off) is detected. SC53-16 The blowout of a fuse for SD/CL in the PF is detected 2. The blowout of a fuse for SD/CL in the PF drive board (PFUDB) is checked. At the start, an error detection signal (blowout of a fuse for the solenoid/ motor) is detected. However, an error detection signal (24V cut off) is not detected. SC53-17 The blowout of the sensor 5VICP is detected. An error detection signal of the blowout of the 5VICP is detected. SC53-18 The fall-off of the erase lamp (EL) CN is detected. When turning ON the power, an error detection signal (fall-off) is detected a specified period of time after the fall-off detection control signal of the EL CN turns ON. SC53-19 An M5 EM error detection signal is detected twice in succession a specified period of time after the conveyance motor (M5) turns ON. SC53-20 An M31 EM error detection signal is detected twice in succession a specified period of time after the ADU reverse/exit motor (M31) turns ON. SC56-02 The communication between the image processing board (IPB) and the operation board /1 (OB1) is checked. An initial communication from the main body to the operation board is not sent within 30 seconds after the power is turned ON. The main body stops immediately to turn OFF the RL1 (main). The main body stops immediately to turn OFF the RL1 (main).

14. MALFUNCTION CODE Estimated abnormal parts PF drive board (PFUDB)

Printer control board (PRCB)

Erase lamp (EL)

Conveyance motor (M5) Printer control board (PRCB)

ADU reverse paper exit motor (M31) Printer control board (PRCB)

Operation board /1 (OB1) Overall control board (OACB)

615

bizhub PRO 1050/1050P 1050e/1050eP

14. MALFUNCTION CODE

Field Service Ver3.0 Nov.2006 Causes Resulting operation If there is a copy being made, the main body and the DF complete the paper exit before stopping operations. Turn OFF the RL1 (main). RADF control board (ADFCB) Estimated abnormal parts Image processing board (IPB)

bizhub PRO 1050/1050P /1050e/1050eP

Classification DF DF abnormality

Code

SC60-01* Although the main body sent out data according to the data transmission request by the DF, the same request is received again. SC60-02* When a checksum error or an SRGA reception error was detected while in the reception in serial communication, a signal was sent to make a request for sending data again. And when data is being received upon this request, a checksum error or an SRGA reception error is detected again. SC60-03* When the main power switch (SW1) is ON, there is no response to the initial communication request from the main body to the DF even after a specified period of time elapses. SC60-11 When the main power switch (SW1) is ON, a region into which no write was made by the ISW is detected in the DF control program. SC67-01 Original registration sensor /Rt (PS306) abnormality. SC67-02 Original conveyance sensor (PS308) abnormality. SC67-03 Original reverse sensor (PS309) abnormality. SC67-04 Non-volatile memory error SC67-05 Cooling fan /Lt (FM301) abnormality. SC67-06 Original reverse sensor (PS309) abnormality. SC67-07 Original reverse/exit sensor (PS313) abnormality. SC67-08 Tray up/down motor (M303) abnormality. SC67-09 Original skew sensor /Fr (PS312) abnormality. SC67-10 Original skew sensor /Rr (PS311) abnormality.

RADF control board (ADFCB)

RADF control board (ADFCB) RADF program

If there is a copy being made, the main body completes the paper exit before stopping operations. Turn OFF the RL1 (main).

Original registration sensor / Rt (PS306) Original conveyance sensor (PS308) Original reverse sensor (PS309) RADF control board (ADFCB) Cooling fan /Lt (FM301) Original reverse sensor (PS309) Original reverse/exit sensor (PS313) Tray up/down motor (M303) Original skew sensor /Fr (PS312) Original skew sensor /Rr (PS311)

616

Field Service Ver3.0 Nov.2006 Classification DF DF abnormality SC67-12 Mis-centering sensor /Fr (PS320) abnormality. SC67-13 Mis-centering sensor /Rr (PS321) abnormality. SC67-14 Multi feed sensor /1 (MFS1) abnormality. FS, FD, SD Commu- SC70-01 FS, FD, SD serial receive error. nication abnormality During re-transmission demand, either one of the error vector occurrence or data checksum error was continuously detected for specified time. SC70-02 FS, FD, SD start up response error. When there is no response to operation starting order, even after several retries. LS LS abnormality SC76-01 The Stacker tray encoder sensor (PS2) does not turn ON within a specified period of time after the stacker tray up down motor (M1) of the tandem (1st) LS turns ON. Or, the initial operation or the stacker tray down operation is not completed within a specified period of time. SC76-02 The shift unit home sensor (PS11) does not turn OFF within a specified period of time after the shift unit motor (M5) of the tandem (1st) LS turns ON. Or, PS11 does not turn ON within a specified period of time. SC76-03 The alignment plate home sensor (PS12) does not turn OFF within a specified period of time after the alignment motor (M7) of the tandem (1st) LS turns ON. Or, PS12 does not turn ON within a specified period of time. The main body and the LS stop immediately to turn OFF the main relay (RL1). The main body , the FS, The FD and the SD stop immediately to turn OFF the main relay (RL1). Code Causes Resulting operation SC67-11 Original registration sensor /Lt (PS318) abnormality. If there is a copy being made, the main body completes the paper exit before stopping operations. Turn OFF the RL1 (main).

14. MALFUNCTION CODE Estimated abnormal parts Original registration sensor / Lt (PS318) Centering sensor /Fr (PS320) Centering sensor /Rr (PS321) Multi feed sensor /1 (MFS1) FNS control board (FNSCB) FD control board (FDCB) SD control board (SDCB)

Stacker tray up down motor (M1) LS control board (LSCB)

Shift unit motor (M5) LS control board (LSCB)

Alignment motor (M7) LS control board (LSCB)

617

bizhub PRO 1050/1050P 1050e/1050eP

14. MALFUNCTION CODE

Field Service Ver3.0 Nov.2006 Causes Resulting operation The main body and the LS stop immediately to turn OFF the main relay (RL1). Stacker tray up down motor (M1) Stacker tray upper limit switch (MS2) Stacker tray up down motor (M1) Stacker tray upper limit switch (MS3) Paper cooling fan motor /Fr (FM1) LS control board (LSCB) Estimated abnormal parts Grip conveyance motor (M4)

bizhub PRO 1050/1050P /1050e/1050eP

Classification LS LS abnormality

Code

SC76-04 The grip conveyance home sensor (PS5) does not turn ON within a specified period of time after the grip conveyance motor (M4) of the tandem (1st) LS turns ON. SC76-05 The stacker tray upper limit switch (MS2) is ON when the stacker tray up down motor (M1) of the tandem (1st) LS is in the up operation. SC76-06 The stacker tray lower limit switch (MS3) is ON when the stacker tray up down motor (M1) of the tandem (1st) LS is in the down operation. SC76-07 An error detection signal is detected for a specified period of time in succession while the paper cooling fan motor /Fr (FM1) of the tandem (1st) LS is ON. SC76-08 An error detection signal is detected for a specified period of time in succession while the cooling fan motor /1 (FM2) of the tandem (1st) LS is ON. SC76-09 An error detection signal is detected for a specified period of time in succession while the paper cooling fan motor /Mi (FM3) of the tandem (1st) LS is ON. SC76-10 An error detection signal is detected for a specified period of time in succession while the motor cooling fan motor (FM4) of the tandem (1st) LS is ON. SC76-11 An error detection signal is detected for a specified period of time in succession while the paper cooling fan motor /Rr (FM5) of the tandem (1st) LS is ON.

Cooling fan motor /1 (FM2) LS control board (LSCB)

Paper cooling fan motor /Mi (FM3) LS control board (LSCB)

Motor cooling fan motor (FM4) LS control board (LSCB)

Paper cooling fan motor /Rr (FM5) LS control board (LSCB)

618

Field Service Ver3.0 Nov.2006 Classification LS LS abnormality Code Causes Resulting operation SC76-31 The stacker tray encoder sensor (PS2) does not turn ON a specified period of time after the stacker tray up down motor (M1) of the tandem (2nd) LS turns ON. Or, the initial operation or the stacker tray down operation is not completed within a specified period of time. SC76-32 The shift unit home sensor (PS11) does not turn OFF within a specified period of time after the shift unit motor (M5) of the tandem (2nd) LS turns ON. Or, PS11 does not turn ON within a specified period of time. SC76-33 The alignment plate home sensor (PS12) does not turn OFF within a specified period of time after the alignment motor (M7) of the tandem (2nd) LS turns ON. Or, PS12 does not turn ON within a specified period of time. SC76-34 The grip conveyance home sensor (PS5) does not turn ON within a specified period of time after the grip conveyance motor (M4) of the tandem (2nd) LS turns ON. SC76-35 The stacker tray upper limit switch (MS2) is ON when the stacker tray up down motor (M1) of the tandem (2nd) LS is in the up operation. SC76-36 The stacker tray lower limit switch (MS3) is ON when the stacker tray up down motor (M1) of the tandem (2nd) LS is in the down operation. SC76-37 An error detection signal is detected for a specified period of time in succession while the paper cooling fan motor /Fr (FM1) of the tandem (2nd) LS is ON. The main body and the LS stop immediately to turn OFF the main relay (RL1).

14. MALFUNCTION CODE Estimated abnormal parts Stacker tray up down motor (M1) LS control board (LSCB)

Shift unit motor (M5) LS control board (LSCB)

Alignment motor (M7) LS control board (LSCB)

Grip conveyance motor (M4)

Stacker tray up down motor (M1) Stacker tray upper limit switch (MS2) Stacker tray up down motor (M1) Stacker tray lower limit switch (MS3) Paper cooling fan motor /Fr (FM1) LS control board (LSCB)

619

bizhub PRO 1050/1050P 1050e/1050eP

14. MALFUNCTION CODE

Field Service Ver3.0 Nov.2006 Causes Resulting operation The main body and the LS stop immediately to turn OFF the main relay (RL1). Paper cooling fan motor /Mi (FM3) LS control board (LSCB) Estimated abnormal parts Paper cooling fan motor /1, /2 (FM2, FM6) LS control board (LSCB)

bizhub PRO 1050/1050P /1050e/1050eP

Classification LS LS abnormality

Code

SC76-38 An error detection signal is detected for a specified period of time in succession while the paper cooling fan motor /1, /2 (FM2, FM6) of the tandem (2nd) LS is ON. SC76-39 An error detection signal is detected for a specified period of time in succession while the paper cooling fan motor /Mi (FM3) of the tandem (2nd) LS is ON. SC76-40 An error detection signal is detected for a specified period of time in succession while the motor cooling fan motor (FM4) of the tandem (2nd) LS is ON. SC76-41 An error detection signal is detected for a specified period of time in succession while the paper cooling fan motor /Rr (FM5) of the tandem (2nd) LS is ON.

Motor cooling fan motor (FM4) LS control board (LSCB)

Paper cooling fan motor /Rr (FM5) LS control board (LSCB)

FS

FS abnormality

SC77-01 The conveyance motor (M1) operates for more than the allowed time at a speed out of the specified one. SC77-02 The tray up down motor (M3) does not turn OFF even when a specified period of time elapses after it starts operations. Or, it operates for more than the allowed time at a speed out of the specified one. SC77-03 The alignment home sensors /Rr (PS8) and /Fr (PS31) do not turn ON within a specified period of time after the home position search operation of the alignment motors /Rr (M5) and /Fr (M22) starts. SC77-04 The main tray paper exit motor (M7) operates for more than the allowed time at a speed out of the specified one.

The main body and the FS stop immediately to turn OFF the main relay (RL1).

FNS control board (FNSCB) FNS drive board (FNSDB) Conveyance motor (M1) FNS control board (FNSCB) FNS drive board (FNSDB) Tray up down motor (M3) Tray upper limit sensor (PS2) Tray lower limit sensor (PS3)

FNS control board (FNSCB) FNS drive board (FNSDB) Alignment motor /Rr (M5) Alignment motor /Fr (M22) Alignment home sensor /Rr (PS8) Alignment home sensor /Fr (PS31) FNS control board (FNSCB) FNS drive board (FNSDB) Main tray exit motor (M7)

620

Field Service Ver3.0 Nov.2006 Classification FS FS abnormality Code Causes Resulting operation SC77-05 The paper exit opening unit does not get to the specified opening position within a specified period of time after the paper exit opening motor (M8) starts operations. SC77-06 The stapler movement home sensor (PS11) does not turn ON within a specified period of time after the home position search operation of the stapler movement motor (M11) starts. SC77-07 The stapler rotation home sensor (PS14) does not turn ON within a specified period of time after the home position search operation of the stapler rotation motor (M4) starts. SC77-08 The stapler rotation home sensor (PS14) does not turn OFF within a specified period of time after the home position search operation of the stapler rotation motor (M4) starts. SC77-11 After the stapler motor /Fr (M31) starts operations, it does not complete operations within a specified period of time, and the stapler home sensor /Fr (PS41) does not turn ON. SC77-12 After the stapler motor /Rr (M30) starts operations, it does not complete operations within a specified period of time, and the stapler home sensor /Rr (PS40) does not turn ON. SC77-15 After the paper exit arm motor (M23) starts operations, it does not complete operations within a specified period of time, and the paper exit arm sensor (PS9) does not turn ON. Or, it operates for more than the allowed time at a speed out of the specified one. The main body and the FS stop immediately to turn OFF the main relay (RL1).

14. MALFUNCTION CODE Estimated abnormal parts FNS control board (FNSCB) FNS drive board (FNSDB) Paper exit opening motor (M8) Paper exit opening sensor (PS12) FNS control board (FNSCB) FNS drive board (FNSDB) Stapler movement motor (M11) Stapler movement home sensor (PS11) FNS control board (FNSCB) FNS drive board (FNSDB) Stapler rotation motor (M4) Stapler rotation home sensor (PS14) FNS control board (FNSCB) FNS drive board (FNSDB) Stapler rotation motor (M4) Stapler rotation home sensor (PS14) FNS control board (FNSCB) FNS drive board (FNSDB) Stapler board (SB) Stapler motor /Fr (M31) Stapler home sensor /Fr (PS41) FNS control board (FNSCB) FNS drive board (FNSDB) Stapler board (SB) Stapler motor /Rr (M30) Stapler home sensor /Rr (PS40) FNS control board (FNSCB) FNS drive board (FNSDB) Paper exit arm motor (M23) Paper exit arm home sensor (PS9)

621

bizhub PRO 1050/1050P 1050e/1050eP

14. MALFUNCTION CODE

Field Service Ver3.0 Nov.2006 Causes Resulting operation The main body and the FS stop immediately to turn OFF the main relay (RL1). Estimated abnormal parts FNS control board (FNSCB) FNS drive board (FNSDB) Rear stopper motor (M26) Rear stopper home sensor (PS35) FNS control board (FNSCB) FNS drive board (FNSDB) Stack assist guide motor (M24) Stack assist home sensor (PS32) FNS control board (FNSCB) FNS drive board (FNSDB) Intermediate roller open close motor (M25) Intermediate roller home sensor (PS33) FNS control board (FNSCB)

bizhub PRO 1050/1050P /1050e/1050eP

Classification FS FS abnormality

Code

SC77-21 After the home position search operation of the rear stopper motor (M26) starts, the rear stopper home sensor (PS35) does not turn ON within a specified period of time. SC77-22 After the home position search operation of the stack assist guide motor (M24) starts, the stack assist home sensor (PS32) does not turn ON within a specified period of time. SC77-25 After the home position search operation of the intermediate roller open close motor (M25) starts, the intermediate roller home sensor (PS33) does not turn ON within a specified period of time. SC77-28 Data was resent according to the re-dispatch request of communication data, but the error recurs.

FD

FD abnormality

SC77-30 After the 1st folding release motor (M14) turns ON, the 1st folding cam home sensor (PS55) does not turn ON within a specified period of time. SC77-31 After the 2nd folding release motor (M15) turns ON, the 2nd folding cam home sensor (PS56) does not turn ON within a specified period of time. SC77-32 After the 3rd folding release motor (M16) turns ON, the 3rd folding cam home sensor (PS57) does not turn ON within a specified period of time. SC77-33 The 2 holes punch home sensor (PS8) does not turn OFF within a specified period of time after the 2 holes punch home position return operation starts. Or, after the punch motor (M10) turns ON, the 2 holes punch home sensor (PS8) does not turn OFF.

The main body and the FD stop immediately to turn OFF the main relay (RL1).

1st folding release motor (M14) Folding drive board (FDB) 1st folding cam home sensor (PS55) 2nd folding release motor (M15) Folding drive board (FDB) 2nd folding cam home sensor (PS56) 3rd folding release motor (M16) Folding drive board (FDB) 3rd folding cam home sensor (PS57) Punch motor (M10) Punch drive board (PDB) 2 holes punch home sensor (PS8)

622

Field Service Ver3.0 Nov.2006 Classification FD FD abnormality Code Causes Resulting operation SC77-34 The 3 holes/4 holes punch home sensor (PS9) does not turn OFF within a specified period of time after the 3 holes/4 holes punch home position return operation starts. Or, after the punch motor (M10) turns ON, the 3 holes/4 holes punch home sensor (PS9) does not turn OFF. SC77-35 The alignment plate home sensor (PS10) does not turn ON within a specified period of time after the alignment plate home position return operation starts. Or, after the alignment motor (M12) turns ON, the alignment plate home sensor (PS10) does not turn OFF. SC77-36 The punch registration home sensor (PS11) does not turn ON within a specified period of time after the punch registration claw home position return operation starts. Or, after the punch registration motor (M13) turns ON, the punch registration home sensor (PS11) does not turn OFF. SC77-37 The main tray upper limit sensor (PS20) does not turn ON within a specified period of time after the main tray home position search starts. Or, after the tray up down motor (M11) turns ON, the main tray upper limit sensor (PS20) does not turn OFF. SC77-38 The main tray lower limit sensor (PS22) does not turn ON within a specified period of time after the tray up down motor (M11) is in the down operation. The main body and the FD stop immediately to turn OFF the main relay (RL1).

14. MALFUNCTION CODE Estimated abnormal parts Punch motor (M10) Punch drive board (PDB) 3 holes/4 holes punch home sensor (PS9)

Alignment motor (M12) Punch drive board (PDB) Alignment plate home sensor (PS10)

Punch registration motor (M13) Punch drive board (PDB) Punch registration home sensor (PS11)

Tray up down motor (M11) Main tray upper limit sensor (PS20) Punch drive board (PDB)

Tray up down motor (M11) Punch drive board (PDB) Main tray lower limit sensor (PS22)

623

bizhub PRO 1050/1050P 1050e/1050eP

14. MALFUNCTION CODE

Field Service Ver3.0 Nov.2006 Causes Resulting operation The main body and the FD stop immediately to turn OFF the main relay (RL1). Estimated abnormal parts Paper lift motor /Up (M8) PI drive board (PIDB) PI lift plate home sensor /Up (PS34) PI tray upper limit sensor / Up (PS32)

bizhub PRO 1050/1050P /1050e/1050eP

Classification FD FD abnormality

Code

SC77-39 After the FD paper lift motor /Up (M8) is in the down operation, the PI lift plate home sensor /Up (PS34) does not turn ON within a specified period of time. Or, after the paper lift motor /Up (M8) is in the up operation, the PI tray upper limit sensor /Up (PS32) does not turn ON. SC77-40 After the FD paper lift motor /Lw (M9) is in the down operation, the PI lift plate home sensor /Lw (PS40) does not turn ON within a specified period of time. Or, after the paper lift motor /Lw (M9) is in the up operation, the PI tray upper limit sensor /Lw (PS38) does not turn ON. SC77-41 The entrance conveyance motor (M1) detects an error detection signal for a specified period of time in succession. SC77-42 The intermediate conveyance motor (M3) detects an error detection signal for a specified period of time in succession. SC77-43 The PI conveyance motor (M7) detects an error detection signal for a specified period of time in succession. SC77-44 The main tray paper exit motor (M17) detects an error detection signal for a specified period of time in succession. SC77-48 Resending of communication data due to an error is not available. SC77-49 When non-volatile memory is being accessed, no response is obtained for a specified period of time. SC77-58* When the FD is unready, a signal to start operations is received from the main body. SC77-59* Communication error in FD

Paper lift motor /Lw (M9) PI drive board (PIDB) PI lift plate home sensor /Lw (PS40) PI tray upper limit sensor / Lw (PS38)

Entrance conveyance motor (M1) Punch drive board (PDB) Intermediate conveyance motor (M3) Punch drive board (PDB) PI conveyance motor (M7) PI drive board (PIDB)

Main tray paper exit motor (M17) Punch drive board (PDB) Main body I/F wiring harness FD control board (FDCB) EEPROM

Software bug

624

Field Service Ver3.0 Nov.2006 Classification SD SD abnormality Code Causes Resulting operation SC77-60 Scraps press home sensor (PS48) does not turn ON within a specified period of time after the bundle drive motor (M5) starts the home position search operation. SC77-61 Folding main scan alignment home sensor /Fr1 (PS18) does not turn ON within a specified period of time after the folding main scan alignment motor /Fr (M7) starts the home position search operation. Or, even after a specified period of time after M7 starts the operation, it does not stop. SC77-62 Folding exit home sensor (PS24) does not turn ON within a specified period of time after the folding sub scan alignment paper exit motor (M8) starts the home position search operation. Or, even after a specified period of time after M8 starts to decelerate, it does not stop. SC77-63 Saddle stitch alignment home sensor /Rt (PS28) does not turn ON within a specified period of time after the saddle stitch alignment motor /Rt (M9) starts the home position search operation. Or, even after a specified period of time after M9 starts the operation, it does not stop. SC77-64 Bundle arm home sensor (PS32) does not turned ON within a specified period of time after the bundle arm motor (M10) starts the home position search operation. Or, even after a specified period of time after M10 starts the operation, it does not stop. The main body and the SD stop immediately to turn OFF the main relay (RL1).

14. MALFUNCTION CODE Estimated abnormal parts Bundle exit motor (M5) Scrap press home sensor (PS48) SD control board (SDCB) SD drive board (SDDB) Folding main scan alignment motor /Fr (M7) Folding main scan alignment home sensor /Fr1 (PS18) SD control board (SDCB) SD drive board (SDDB)

Folding sub scan alignment exit motor (M8) Folding exit home sensor (PS24) SD control board (SDCB) SD drive board (SDDB)

Saddle stitching alignment motor /Rt (M9) Saddle stitching alignment home sensor /Rt (PS28) SD control board (SDCB) SD drive board (SDDB)

Bundle arm motor (M10) Bundle arm home sensor (PS32) SD control board (SDCB) SD drive board (SDDB)

625

bizhub PRO 1050/1050P 1050e/1050eP

14. MALFUNCTION CODE

Field Service Ver3.0 Nov.2006 Causes Resulting operation The main body and the SD stop immediately to turn OFF the main relay (RL1). Estimated abnormal parts Bundle clip motor (M11) Bundle clip upper limit sensor (PS33) Bundle clip lower limit sensor (PS30) SD control board (SDCB) SD drive board (SDDB) Bundle registration motor (M12) Bundle registration home sensor (PS34) SD control board (SDCB) SD drive board (SDDB)

bizhub PRO 1050/1050P /1050e/1050eP

Classification SD SD abnormality

Code

SC77-65 Bundle clip upper limit sensor (PS33) does not turned ON within a specified period of time after the bundle clip motor (M11) starts the home position search operation. Or, even after a specified period of time after M11 starts the operation, it does not stop. SC77-66 Bundle registration home sensor (PS34) does not turned ON within a specified period of time after the bundle registration motor (M12) starts the home position search operation. Or, even after a specified period of time after M12 starts the operation, it does not stop. SC77-67 Overlap home sensor (PS17) does not turned ON within a specified period of time after the overlap motor (M13) starts the home position search operation. Or, even after a specified period of time after M13 starts the operation, it does not stop. SC77-68 Folding main scan alignment home sensor /Rr (PS19) does not turned ON within a specified period of time after the folding main scan alignment motor /Rr (M14) starts the home position search operation. Or, even after a specified period of time after M14 starts the operation, it does not stop. SC77-69 Stapler moving home sensor (PS25) does not turned ON within a specified period of time after the stapler moving motor (M15) starts the home position search operation. Or, even after a specified period of time after M15 starts the operation, it does not stop.

Overlap motor (M13) Overlap home sensor (PS17) SD control board (SDCB) SD drive board (SDDB)

Folding main scan alignment motor /Rr (M14) Folding main scan alignment home sensor /Rr (PS19) SD control board (SDCB) SD drive board (SDDB)

Stapler movement motor (M15) Stapler movement home sensor (PS25) SD control board (SDCB) SD drive board (SDDB)

626

Field Service Ver3.0 Nov.2006 Classification SD SD abnormality Code Causes Resulting operation SC77-70 Saddle stitching alignment home sensor /Lt (PS29) does not turned ON within a specified period of time after the saddle stitching alignment motor /Lt (M16) starts the home position search operation. Or, even after a specified period of time after M16 starts the operation, it does not stop. SC77-71 Bundle press movement home sensor (PS36) does not turned ON within a specified period of time after the bundle press movement motor (M17) starts the home position search operation. Or, even after a specified period of time after M17 starts the operation, it does not stop. SC77-72 1st folding blade home sensor /2 (PS21) does not turned ON within a specified period of time after the 1st folding blade motor (M18) starts the home position search operation. Or 1st folding blade home sensor /1 (PS20) does not turned ON within a specified period of time after M18 starts the operation. SC77-73 2nd folding blade home sensor /2 (PS23) does not turned ON within a specified period of time after the 2nd folding blade motor (M19) starts the home position search operation. Or the 2nd folding blade home sensor /1 (PS22) does not turned ON within a specified period of time after M19 starts the operation. The main body and the SD stop immediately to turn OFF the main relay (RL1).

14. MALFUNCTION CODE Estimated abnormal parts Saddle stitching alignment motor /Lt (M16) Saddle stitching alignment home sensor /Lt (PS29) SD control board (SDCB) SD drive board (SDDB)

Bundle press movement motor (M17) Bundle press movement home sensor (PS36) SD control board (SDCB) SD drive board (SDDB)

1st folding blade motor (M18) 1st folding blade home sensor /1 (PS20), /2 (PS21) SD control board (SDCB) SD drive board (SDDB)

2nd folding blade motor (M19) 2nd folding blade home sensor /1 (PS22), /2 (PS23) SD control board (SDCB) SD drive board (SDDB)

627

bizhub PRO 1050/1050P 1050e/1050eP

14. MALFUNCTION CODE

Field Service Ver3.0 Nov.2006 Causes Resulting operation The main body and the SD stop immediately to turn OFF the main relay (RL1). Estimated abnormal parts Clincher up down motor (M20) Clincher up/down home sensor (PS26) SD control board (SDCB) SD drive board (SDDB)

bizhub PRO 1050/1050P /1050e/1050eP

Classification SD SD abnormality

Code

SC77-74 Clincher up down home sensor (PS26) does not turned ON within a specified period of time after the clincher up down motor (M20) starts the home position search operation. Or, even after a specified period of time after M20 starts the operation, it does not stop. SC77-75 Saddle stitching press home sensor (PS27) does not turned ON within a specified period of time after the saddle stitching press motor (M21) starts the home position search operation. Or, even after a specified period of time after M21 starts the operation, it does not stop. SC77-76 Bundle arm rotation home sensor (PS31) does not turned ON within a specified period of time after the bundle arm rotation motor (M22) starts the home position search operation. Or, even after a specified period of time after M22 starts the operation, it does not stop. SC77-77 Bundle press home sensor (PS37) does not turned ON within a specified period of time after the bundle press motor (M23) starts the home position search operation. Or, even after a specified period of time after M23 starts the operation, it does not stop. SC77-78 Bundle press stage up down home sensor (PS35) does not turned ON within a specified period of time after the bundle press stage up down motor (M24) starts the home position search operation. Or PS35 or the bundle press stage up down upper limit sensor (PS45) does not turned ON after a specified period of time M24 starts the operation.

Saddle stitching press motor (M21) Saddle stitching press home sensor (PS27) SD control board (SDCB) SD drive board (SDDB)

Bundle arm rotation motor (M22) Bundle arm rotation home sensor (PS31) SD control board (SDCB) SD drive board (SDDB)

Bundle press motor (M23) Bundle press home sensor (PS37) Bundle press lower limit sensor (PS47) SD control board (SDCB) SD drive board (SDDB) . Bundle press stage up down motor (M24) Bundle press stage up down home sensor (PS35) Bundle press stage up down limit sensor (PS45) SD control board (SDCB) SD drive board (SDDB)

628

Field Service Ver3.0 Nov.2006 Classification SD SD abnormality Code Causes Resulting operation SC77-79 Guide shaft home sensor (PS46) does not turned ON within a specified period of time after the guide shaft motor (M25) starts the home position search operation. Or, even after a specified period of time after M25 starts the operation, it does not stop. SC77-80 Stapler home sensor /Rt (HS1) or clincher start sensor /Rt (HS2) does not turned ON within a specified period of time after the stapler motor /Rt (M29) starts the operation. SC77-81 Stapler home sensor /Lt (HS3) or clincher start sensor /Lt (HS4) does not turned ON within a specified period of time after the stapler motor /Lt (M30) starts the operation. SC77-82 Trimmer blade motor (M31) does not turned OFF within a specified period of time after it turned ON. The main body and the SD stop immediately to turn OFF the main relay (RL1).

14. MALFUNCTION CODE Estimated abnormal parts Guide shaft motor (M25) Guide shaft home sensor (PS46) SD control board (SDCB) SD drive board (SDDB)

Stapler assembly /Rt SD control board (SDCB) SD drive board (SDDB)

Stapler assembly /Lt SD control board (SDCB) SD drive board (SDDB)

Trimmer blade motor (M31) Trimmer blade home sensor (PS50) Trimmer blade upper limit sensor (PS51) SD control board (SDCB) SD drive board (SDDB)

SC77-83 Trimmer press motor (M32) does not turned OFF within a specified period of time after it turned ON.

Trimmer press motor (M32) Trimmer press home motor (PS53) Trimmer press upper limit sensor (PS52) SD control board (SDCB) SD drive board (SDDB)

SC77-84 Bundle arm assist motor (M26) does not turned OFF within a specified period of time after it turned ON.

Bundle arm assist motor (M26) Bundle arm assist home sensor (PS38) Bundle arm assist upper limit sensor (PS39) SD control board (SDCB) SD drive board (SDDB)

SC77-85 An error detection signal is detected for a specified period of time in succession while the entrance conveyance motor (M1) is ON.

Entrance conveyance motor (M1) SD control board (SDCB) SD drive board (SDDB)

629

bizhub PRO 1050/1050P 1050e/1050eP

14. MALFUNCTION CODE

Field Service Ver3.0 Nov.2006 Causes Resulting operation The main body and the SD stop immediately to turn OFF the main relay (RL1). Folding entrance motor (M3) SD control board (SDCB) SD drive board (SDDB) Folding conveyance motor (M4) SD control board (SDCB) SD drive board (SDDB) Bundle exit motor (M5) SD control board (SDCB) SD drive board (SDDB) Folding sub scan alignment exit motor (M8) SD control board (SDCB) SD drive board (SDDB) Scraps removal fan motor (FM1) SD control board (SDCB) SD drive board (SDDB) Estimated abnormal parts Horizontal conveyance motor (M2) SD control board (SDCB) SD drive board (SDDB)

bizhub PRO 1050/1050P /1050e/1050eP

Classification SD SD abnormality

Code

SC77-86 An error detection signal is detected for a specified period of time in succession while the horizontal conveyance motor (M2) is ON. SC77-87 An error detection signal is detected for a specified period of time in succession while the folding entrance motor (M3) is ON. SC77-88 An error detection signal is detected for a specified period of time in succession while the folding conveyance motor (M4) is ON. SC77-89 An error detection signal is detected for a specified period of time in succession while the bundle exit motor (M5) is ON. SC77-90 An error detection signal is detected for a specified period of time in succession while the folding sub scan alignment exit motor (M8) is ON. SC77-91 An error detection signal is detected for a specified period of time in succession while the scraps removal fan motor (FM1) is ON. And normal operation is not detected after the restart (retry). (even after being started for the specified times) Or, an error detection is detected at the start operation and normal operation is not detected even after the restart (retry). (normal operation is not detected after the start of the specified times after error detection) SC77-95 5VDC power supply error detection signal is detected for a specified period of time in succession. SC77-96 Resending of communication data to the main body is not available due to an error.

SD drive board (SDDB) SD control board (SDCB) SD control board (SDCB)

630

Field Service Ver3.0 Nov.2006 Classification SD SD abnormality Code Causes Resulting operation SC77-97 When non-volatile memory is being accessed, no response is obtained for a specified period of time. SC77-98* When the SD is unready, a signal to start operations is received from the main body. SC77-99* Communication error in SD PB PB abnormality SC78-01 After the main CPU in the PB control board (PBCB) sends an entrance conveyance start signal to the sub CPU, a signal to notify the completion of the procvess is not returned to the main CPU within a specified time period. SC78-02 An error detection signal is detected continuously for a specified time period while the intermediate conveyance motor (M2) is driving. SC78-04 After the main CPU on the PB control board (PBCB) sends a SC entrance conveyance start signal to the sub CPU, a signal to notify the completion of the process is not returned to the main CPU within a specified time period. SC78-05 After the main CPU on the PB control board (PBCB) sends a SC switchback conveyance start signal to the sub CPU, a signal to notify the completion of the process is not returned to the main CPU within a specified time period. SC78-06 The switchback roller release operation has not completed within a specified time period after the SC switchback release motor (M13) turns ON. SC78-07 After the main CPU on the PB control board (PBCB) sends an SC alignment start signal to the sub CPU, a signal to notify the completion of the process is not returned to the main CPU within a specified time period. The main body and the PB stop immediately to turn OFF the main relay (RL1). The main body and the SD stop immediately to turn OFF the main relay (RL1).

14. MALFUNCTION CODE Estimated abnormal parts SD control board (SDCB) EEPROM Software bug

PB control board (PBCB) PB drive board (PBDB) Entrance conveyance motor (M1)

PB control board (PBCB) PB drive board (PBDB) Intermediate conveyance motor (M2) PB control board (PBCB) PB drive board (PBDB) SC entrance conveyance motor (M11)

PB control board (PBCB) PB drive board (PBDB) SC switchback conveyance motor (M12)

PB control board (PBCB) PB drive board (PBDB) SC switchback release motor (M13) PB control board (PBCB) PB drive board (PBDB) SC alignment motor (M15)

631

bizhub PRO 1050/1050P 1050e/1050eP

14. MALFUNCTION CODE

Field Service Ver3.0 Nov.2006 Causes Resulting operation The main body and the PB stop immediately to turn OFF the main relay (RL1). Estimated abnormal parts PB control board (PBCB) PB drive board (PBDB) SC bundle conveynace motor (M17)

bizhub PRO 1050/1050P /1050e/1050eP

Classification PB PB abnormality

Code

SC78-08 After the main CPU on the PB control board (PBCB) sends an SC pages conveyance start signal to the sub CPU, a signal to notify the completion of the process is not returned to the main CPU within a specified time period. SC78-09 The SC roller release operation has not completed within a specified time period after the SC roller release motor (M18) turns ON. SC78-10 The movement of the SC entrance has not completed within a specified time period after the clamp entrance movement motor (M19) turns ON. SC78-11 The SC entrance roller release operation has not completed within a specified time period after the clamp entrance roller release motor (M20) turns ON SC78-12 After clamp alignment motor (M21) turns on, the alignment operation is not complete within the specified time. SC78-13 After clamp motor (M22) turns on, the open/close process of the clamp section is not complete within the specified time. SC78-14 The rotation of the clamp section has not completed within a specified time period after the clamp rotation motor (M23) turns ON. SC78-15 The movement of the glue tank has not completed within a specified time period after the glue tank movement motor (M31) turns ON. SC78-16 An error detection signal is detected continuously for a specified time period while the glue apply roller motor (M32) is driving.

PB control board (PBCB) PB drive board (PBDB) SC roller release motor (M18) PB control board (PBCB) PB drive board (PBDB) Clamp entranse movement motor (M19) PB control board (PBCB) PB drive board (PBDB) Clamp entranse roller release motor (M20) PB control board (PBCB) PB drive board (PBDB) Clamp alignment motor (M21) PB control board (PBCB) PB drive board (PBDB) Clamp motor (M22) PB control board (PBCB) PB drive board (PBDB) Clamp rotation motor (M23) PB control board (PBCB) PB drive board (PBDB) Glue tank movement motor (M31) PB control board (PBCB) PB drive board (PBDB) Glue apply roller motor (M32)

632

Field Service Ver3.0 Nov.2006 Classification PB PB abnormality Code Causes Resulting operation SC78-17 The count of a specified number of pellets, which is counted by the pellet count sensor (PS37), has not been reached after the pellet supply motor (M33) turns ON. The status was detected by a specified number of times in succession. SC78-18 The movement of the pellet supply arm has not completed within a specified time period after the pellet supply arm motor (M34) turns ON. SC78-19 After the main CPU on the PB control board (PBCB) sends a SC alignment start signal to the sub CPU, a signal to notify the completion of the process is not returned to the main CPU within a specified time period. SC78-20 After the main CPU on the PB control board (PBCB) sends a book ejection start signal to the sub CPU, a signal to notify the completion of the process is not returned to the main CPU within a specified time period. SC78-21 After the main CPU on the PB control board (PBCB) sends a driven arm/Rt shaking operation start signal to the sub CPU, a signal to notify the completion of the process is not returned to the main CPU within a specified time period. SC78-22 After the main CPU in the PB control board (PBCB) sends a driven arm/Lt shaking operation start signal to the sub CPU, a signal to notify the completion of the process is not returned to the main CPU within a specified time period. The main body and the PB stop immediately to turn OFF the main relay (RL1).

14. MALFUNCTION CODE Estimated abnormal parts PB control board (PBCB) PB drive board (PBDB) Pellet supply motor (M33)

PB control board (PBCB) PB drive board (PBDB) pellet supply arm motor (M34) PB control board (PBCB) PB drive board (PBDB) Cover paper alignment motor (M41)

PB control board (PBCB) PB drive board (PBDB) Book exit motor (M42)

PB control board (PBCB) PB drive board (PBDB) Cover paper conveyance arm motor /Rt (M43)

PB control board (PBCB) PB drive board (PBDB) Cover paper conveyance arm motor /Lt (M44)

633

bizhub PRO 1050/1050P 1050e/1050eP

14. MALFUNCTION CODE

Field Service Ver3.0 Nov.2006 Causes Resulting operation The main body and the PB stop immediately to turn OFF the main relay (RL1). Estimated abnormal parts PB control board (PBCB) PB drive board (PBDB) Cover paper conveyance motor (M45)

bizhub PRO 1050/1050P /1050e/1050eP

Classification PB PB abnormality

Code

SC78-23 After the main CPU on the PB control board (PBCB) sends a cover paper conveyance start signal to the sub CPU, a signal to notify the completion of the process is not returned to the main CPU within a specified time period. SC78-24 The cover paper table up or down movement has not completed within a specified time period after the cover paper table up down motor/Fr (M46) turns ON. SC78-25 The cover paper table up or down movement has not completed within a specified time period after the cover paper table up down motor/Rr (M47) turns ON. SC78-26 The movement of the cover paper folding plate/Rt has not completed within a specified time period after the cover paper folding motor/Rt (M48) turns ON. SC78-27 The movement of the cover paper folding plate/Lt has not completed within a specified time period after the cover paper folding motor/Lt (M49) turns ON. SC78-28 The trimming of the cover paper has not completed within a specified time period after the cutter motor (M50) turns ON. SC78-30 After the main CPU in the PB control board (PBCB) sends a carriage belt driving operation start signal to the sub CPU, a signal to notify the completion of the process is not returned to the main CPU within a specified time period. SC78-31 The carriage section movement according to paper size has not completed after the book conveyance belt movement motor (M62) turns ON.

PB control board (PBCB) PB drive board (PBDB) Cover paper table up down motor /Fr (M46) PB control board (PBCB) PB drive board (PBDB) Cover paper table up down motor /Rr (M47) PB control board (PBCB) PB drive board (PBDB) Cover paper folding motor / Rt (M48) PB control board (PBCB) PB drive board (PBDB) Cover paper folding motor / Lt (M49) PB control board (PBCB) PB drive board (PBDB) Cutter motor (M50) PB control board (PBCB) PB drive board (PBDB) Book conveyance belt motor (M61)

PB control board (PBCB) PB drive board (PBDB) Book conveyance belt movement motor (M62)

634

Field Service Ver3.0 Nov.2006 Classification PB PB abnormality Code Causes Resulting operation SC78-32 The up/down process of the carriage section has not completed within a specified time period after the cover paper conveyance belt up/down motor (M63) turns ON. SC78-34 The pressing of the back edge of the book process has not completed within a specified time period after the book stopper motor (M65) turns ON. SC78-35 An error detection signal is detected continuously for specified time period while the cover paper tray fan/1 (M71) is started or driving. SC78-36 An error detection signal is detected continuously for specified time period while the cover paper tray fan/2 (M72) is started or driving. SC78-37 The tray up movement has not completed within a specified time period after the cover paper tray lift motor (M73) turns ON. SC78-38 An error detection signal is detected continuously for a specified time period while the cover paper feed motor (M74) is driving. SC78-39 An error detection signal is detected continuously for specified time period while the ventilation fan/1 (M80), /2 (M81) is started of driving. SC78-40 After the warm-up is started, tem** perature detected by the glue tank temperature sensor /Md (TH3) has not risen to a prescribed level within a specified time period. The main body and the PB stop immediately to turn OFF the main relay (RL1).

14. MALFUNCTION CODE Estimated abnormal parts PB control board (PBCB) PB drive board (PBDB) Book conveyance belt up down motor (M63) PB control board (PBCB) PB drive board (PBDB) Book stopper motor (M65)

PB control board (PBCB) PB drive board (PBDB) Cover paper tray fan /1 (M71) PB control board (PBCB) PB drive board (PBDB) Cover paper tray fan /2 (M72) PB control board (PBCB) PB drive board (PBDB) Cover paper tray lift motor (M73) PB control board (PBCB) PB drive board (PBDB) Cover paper feed motor (M74) PB control board (PBCB) PB drive board (PBDB) Exhaust fan /1 (M80) Exhaust fan /2 (M81) AC drive board (ACDB) Glue tank heater (H1) Glue apply roller heater (H2) PB control board (PBCB) PB drive board (PBDB) Glue apply roller motor (M32) Glue tank temperature sensor /Md (TH3)

635

bizhub PRO 1050/1050P 1050e/1050eP

14. MALFUNCTION CODE

Field Service Ver3.0 Nov.2006 Causes Resulting operation The main body and the PB stop immediately to turn OFF the main relay (RL1). Estimated abnormal parts AC drive board (ACDB) Glue tank heater (H1) Glue apply roller heater (H2) PB control board (PBCB) PB drive board (PBDB) Glue apply roller motor (M32) Glue tank temperature sensor /Lw (TH4)

bizhub PRO 1050/1050P /1050e/1050eP

Classification PB PB abnormality

Code

SC78-41 After the warm-up is started, tem** perature detected by the glue tank temperature sensor /Lw (TH4) has not risen to a prescribed level within a specified time period.

SC78-42 After the warm-up is started, tem** perature detected by the glue apply roller temperature sensor (TH1) has not risen to a prescribed level within a specified time period.

AC drive board (ACDB) Glue tank heater (H1) Glue apply roller heater (H2) PB control board (PBCB) PB drive board (PBDB) Glue apply roller motor (M32) Glue apply roller temperature sensor (TH1)

SC78-43 After the pellet supply, tempera** ture detected by the glue tank temperature sensor/Up (TH2) has not risen to a prescribed level within a specified time period.

AC drive board (ACDB) Glue tank heater (H1) Glue apply roller heater (H2) PB control board (PBCB) PB drive board (PBDB) Glue apply roller motor (M32) Glue tank temperature sensor /Up (TH2)

SC78-44 During standby, after the glue tank ** heater (H1) is turned ON, temperature detected by the glue tank temperature sensor /Md (TH3) has not risen to a prescribed level within a specified time period.

AC drive board (ACDB) Glue tank heater (H1) Glue apply roller heater (H2) PB control board (PBCB) PB drive board (PBDB) Glue apply roller motor (M32) Glue tank temperature sensor /Md (TH3)

SC78-45 When control temperature is ** reached, after the glue tank heater (H1) is turned ON, temperature detected by the glue tank temperature sensor/Lw (TH4) has not risen to a prescribed level within a specified time period.

AC drive board (ACDB) Glue tank heater (H1) Glue apply roller heater (H2) PB control board (PBCB) PB drive board (PBDB) Glue apply roller motor (M32) Glue tank temperature sensor /Lw (TH4)

636

Field Service Ver3.0 Nov.2006 Classification PB PB abnormality Code Causes Resulting operation SC78-46 When control temperature is ** reached, after the glue tank heater (H1) is turned ON, temperature detected by the glue apply roller temperature sensor (TH1) has not risen to a prescribed level within a specified time period. The main body and the PB stop immediately to turn OFF the main relay (RL1).

14. MALFUNCTION CODE Estimated abnormal parts AC drive board (ACDB) Glue tank heater (H1) Glue apply roller heater (H2) PB control board (PBCB) PB drive board (PBDB) Glue apply roller motor (M32) Glue apply roller temperature sensor (TH1)

SC78-47 An abnormal high temperature is ** detected by the glue apply roller temperature sensor (TH1).

AC drive board (ACDB) Glue tank heater (H1) Glue apply roller heater (H2) PB control board (PBCB) PB drive board (PBDB) Glue apply roller motor (M32) Glue apply roller temperature sensor (TH1)

SC78-48 An abnormal high temperature is ** detected by the glue tank temperature sensor /Up (TH2).

AC drive board (ACDB) Glue tank heater (H1) Glue apply roller heater (H2) PB control board (PBCB) PB drive board (PBDB) Glue apply roller motor (M32) Glue tank temperature sensor /Up (TH2)

SC78-49 An abnormal high temperature is ** detected by the glue tank temperature sensor /Md (TH3).

AC drive board (ACDB) Glue tank heater (H1) Glue apply roller heater (H2) PB control board (PBCB) PB drive board (PBDB) Glue apply roller motor (M32) Glue tank temperature sensor /Md (TH3)

SC78-50 An abnormal high temperature is ** detected by the glue tank temperature sensor /Lw (TH4).

AC drive board (ACDB) Glue tank heater (H1) Glue apply roller heater (H2) PB control board (PBCB) PB drive board (PBDB) Glue apply roller motor (M32) Glue tank temperature sensor /Lw (TH4)

637

bizhub PRO 1050/1050P 1050e/1050eP

14. MALFUNCTION CODE

Field Service Ver3.0 Nov.2006 Causes Resulting operation The main body and the PB stop immediately to turn OFF the main relay (RL1). Estimated abnormal parts AC drive board (ACDB) Glue tank heater (H1) Glue apply roller heater (H2) PB control board (PBCB) PB drive board (PBDB) Glue apply roller motor (M32) Glue apply roller temperature sensor (TH1)

bizhub PRO 1050/1050P /1050e/1050eP

Classification PB PB abnormality

Code

SC78-51 The glue apply roller temperature ** sensor (TH1) high temperature hardware detection. An abnormal high temperature is detected by the glue apply roller temperature sensor (TH1).

SC78-52 The glue tank temperature sensor ** /Up (TH2) high temperature hardware detection. An abnormal high temperature is detected by the glue tank temperature sensor /Up (TH2).

AC drive board (ACDB) Glue tank heater (H1) Glue apply roller heater (H2) PB control board (PBCB) PB drive board (PBDB) Glue apply roller motor (M32) Glue tank temperature sensor /Up (TH2)

SC78-53 The glue tank temperature sensor ** /Md (TH3) high temperature hardware detection. An abnormal high temperature is detected by the glue tank temperature sensor /Md (TH3).

AC drive board (ACDB) Glue tank heater (H1) Glue apply roller heater (H2) PB control board (PBCB) PB drive board (PBDB) Glue apply roller motor (M32) Glue tank temperature sensor /Md (TH3)

SC78-54 The glue tank temperature sensor ** /Lw (TH4) high temperature hardware detection. An abnormal high temperature is detected by the glue tank temperature sensor /Lw (TH4).

AC drive board (ACDB) Glue tank heater (H1) Glue apply roller heater (H2) PB control board (PBCB) PB drive board (PBDB) Glue apply roller motor (M32) Glue tank temperature sensor /Lw (TH4)

SC78-55 An abnormal low temperature is ** detected by the glue apply roller temperature sensor (TH1), after completion of warm-up.

AC drive board (ACDB) Glue tank heater (H1) Glue apply roller heater (H2) PB control board (PBCB) PB drive board (PBDB) Glue apply roller motor (M32) Glue apply roller temperature sensor (TH1)

638

Field Service Ver3.0 Nov.2006 Classification PB PB abnormality Code Causes Resulting operation SC78-56 An abnormal low temperature is ** detected by the glue tank temperature sensor /Up (TH2), after reaching glue supply control temperature. The main body and the PB stop immediately to turn OFF the main relay (RL1).

14. MALFUNCTION CODE Estimated abnormal parts AC drive board (ACDB) Glue tank heater (H1) Glue apply roller heater (H2) PB control board (PBCB) PB drive board (PBDB) Glue apply roller motor (M32) Glue tank temperature sensor /Up (TH2)

SC78-57 An abnormal low temperature is ** detected by the glue tank temperature sensor /Md (TH3), after the warming-up is completed.

AC drive board (ACDB) Glue tank heater (H1) Glue apply roller heater (H2) PB control board (PBCB) PB drive board (PBDB) Glue apply roller motor (M32) Glue tank temperature sensor /Md (TH3)

SC78-58 An abnormal low temperature is ** detected by the glue tank temperature sensor /Lw (TH4), after the warming-up is completed.

AC drive board (ACDB) Glue tank heater (H1) Glue apply roller heater (H2) PB control board (PBCB) PB drive board (PBDB) Glue apply roller motor (M32) Glue tank temperature sensor /Lw (TH4)

SC78-59 Glue apply roller temperature sen** sor (TH1) low temperature abnormality hardware detection. TH1 detected low temperature abnormality of the glue apply roller abnormality detection signal after the warming-up is completed.

AC drive board (ACDB) Glue tank heater (H1) Glue apply roller heater (H2) PB control board (PBCB) PB drive board (PBDB) Glue apply roller motor (M32) Glue apply roller temperature sensor (TH1)

SC78-60 Glue tank temperature sensor/Up ** (TH2) low temperature abnormality hardware detection . TH2 detected low temperature abnormality of the glue tank abnormality detection signal after reaching the glue supply control temperature.

AC drive board (ACDB) Glue tank heater (H1) Glue apply roller heater (H2) PB control board (PBCB) PB drive board (PBDB) Glue apply roller motor (M32) Glue tank temperature sensor /Up (TH2)

639

bizhub PRO 1050/1050P 1050e/1050eP

14. MALFUNCTION CODE

Field Service Ver3.0 Nov.2006 Causes Resulting operation The main body and the PB stop immediately to turn OFF the main relay (RL1). Estimated abnormal parts AC drive board (ACDB) Glue tank heater (H1) Glue apply roller heater (H2) PB control board (PBCB) PB drive board (PBDB) Glue apply roller motor (M32) Glue tank temperature sensor /Md (TH3)

bizhub PRO 1050/1050P /1050e/1050eP

Classification PB PB abnormality

Code

SC78-61 Glue tank temperature sensor/Md ** (TH3) low temperature abnormality hardware detection. TH3 detected low temperature abnormality of the glue tank abnormality detection signal after the warming-up is completed.

SC78-62 Glue tank temperature sensor /Lw ** (TH4) low temperature abnormality hardware detection. TH4 detected low temperature abnormality of the glue tank abnormality detection signal after the warming-up is completed.

AC drive board (ACDB) Glue tank heater (H1) Glue apply roller heater (H2) PB control board (PBCB) PB drive board (PBDB) Glue apply roller motor (M32) Glue tank temperature sensor /Lw (TH4)

SC78-63 Abnormal rotation of the exhaust fan/2 (M81) on start-up does not recover by reboot. Abnormal rotation of the exhaust fan/2 (M81) during M81 is on does not recover by reboot. SC78-64 Abnormal rotation of the pellet cooler fan (M4) on start-up does not recover by reboot. Abnormal rotation of the pellet cooler fan (M4) during M4 is on does not recover by reboot. SC78-91 Message queue full or the control abnormality of Sub CPU1 in the PB control board (PBCB). SC78-92 Message queue full or the control abnormality of Sub CPU2 in the PB control board (PBCB). SC78-93 Communication abnormality between Main CPU in the PB control board (PBCB) and Sub CPU1. SC78-94 Communication abnormality between Main CPU in the PB control board (PBCB) and Sub CPU2. SC78-96 Paper feed abnormality between the main body and the PB. SC78-97 Non-volatile memory error in the PB control board (PBCB).

AC drive board (ACDB) PB control board (PBCB) PB drive board (PBDB) Exhaust fan /2 (M81)

AC drive board (ACDB) PB control board (PBCB) PB drive board (PBDB) Pellet supply cooling fan motor (M4) PB control board (PBCB) Control program PB control board (PBCB) Control program PB control board (PBCB) Control program PB control board (PBCB) Control program PB control board (PBCB) Control program PB control board (PBCB) Control program

640

Field Service Ver3.0 Nov.2006 Classification PB PB abnormality Code Causes Resulting operation SC78-98 PB operation prohibition abnormality. PB received operation start signal from the main body when the PB is unready. SC78-99 Message queue of the communication among tasks in the PB is full. Main body Commu- SC80-01 In the communication check nication abnormality between the image processing board (IPB) and the printer control board (PRCB), the printer control does not respond within a specified period of time after the main power switch (SW1) and the sub power switch (SW2) turn ON. Or ISW information is not written on PRCB. SC80-02 In the communication check between the image processing board (IPB) and the printer control board (PRCB), an error is detected from PRCB. Or transmission is not completed. SC80-03 In the communication check between the image processing board (IPB) and the operation board (OB1), an error is detected from the OB1. Or transmission is not completed. SC80-11 ISW information is not written on Printer control board (PRCB). SC80-30 No normal header is transmitted within a specified period of time after ISW is started. SC80-31 An error is detected while downloading ISW. The main body stops immediately to turn OFF the main relay (RL1). The main body and the PB stop immediately to turn OFF the main relay (RL1).

14. MALFUNCTION CODE Estimated abnormal parts Control program

Control program

Overall control board (OACB) Printer control board (PRCB) Loose connection

Overall control board (OACB) Operation board /1 (OB1) Loose connection

Printer control board (PRCB) Overall control board (OACB) ISW Cable Overall control board (OACB) ISW file abnormality ISW Cable

SC80-32 An error is detected because ISW data cannot be written on image processing board (IPB). FD SC80-40 The firmware is not written on FD or an error is detected during the ROM check.

ROM on each board Inter-board communication harness FD firmware FD control board (FDCB) Wiring harness between the FDCB and the main body

641

bizhub PRO 1050/1050P 1050e/1050eP

14. MALFUNCTION CODE

Field Service Ver3.0 Nov.2006 Causes Resulting operation The main body stops immediately to turn OFF the main relay (RL1). Estimated abnormal parts SD firmware SD control board (SDCB) Wiring harness between the SDCB and the main body FS firmware FNS control board (FNSCB) Wiring harness between the FNSCB and the main body LS firmware LS control board (LSCB) Wiring harness between the LSCB and the main body LS firmware LS control board (LSCB) Wiring harness between the LSCB and the main body IC firmware IC board (ICB) PB firmware PB control board (PBCB) Printer control board (PRCB) ADU drive board /1 (ADJDB1) Loose connection

bizhub PRO 1050/1050P /1050e/1050eP

Classification SD Communication abnormality FS

Code

SC80-41 The firmware is not written on SD or an error is detected during the ROM check. SC80-42 The firmware is not written on FS or an error is detected during the ROM check.

LS

SC80-43 The firmware is not written on first LS or an error is detected during the ROM check. SC80-44 The firmware is not written on second LS or an error is detected during the ROM check.

IC

SC80-45 The firmware is not written on ICB or an error is detected during the ROM check.

PB

SC80-46 The firmware is not written on PB or an error is detected during the ROM check. SC90-01 In the initial communication check between ADU drive board /1 (ADJDB1) and printer control board (PRCB), no response is returned from ADUDB1 after a specified time from turning ON of the main power switch (SW1) and sub power switch (SW2) (ID=0). SC90-02 In the initial communication check between ADU drive board /1 (ADJDB2) and printer control board (PRCB), no response is returned from ADUDB2 after a specified time from turning ON of the main power switch (SW1) and sub power switch (SW2) (ID7). SC90-03 In the communication check between ADU drive board /1 (ADUDB1) and printer control board (PRCB), an error was detected (ID=0). SC90-04 In the communication check between ADU drive board /1 (ADUDB2) and printer control board (PRCB), an error was detected (ID=').

Main body

Printer control board (PRCB) ADU drive board /1 (ADJDB1) Loose connection

Printer control board (PRCB) ADU drive board /1 (ADJDB1) Loose connection Printer control board (PRCB) ADU drive board /1 (ADJDB1) Loose connection

642

Field Service Ver3.0 Nov.2006 Classification Main body Code Causes Resulting operation Commu- SC90-05 In the initial communication check nication abnormality between ADU drive board /1 (ADJDB1) and printer control board (PRCB), no response is returned from ADUDB1 after a specified time from turning ON of the main power switch (SW1) and sub power switch (SW2) (ID=11). SC90-06 In the communication check between ADU drive board /1 (ADUDB1) and printer control board (PRCB), an error was detected (ID=11). Power SC93-01 Error detection signal (blown fuse) abnormality of ADU drive board /1 (ADUDB1) was detected. SC93-05 Error detection signal (blown fuse) of offset sensor (PS54) or transfer exposure lamp (TSL) was detected and an error signal (24V disconnection) was detected. SC93-06 Error detection signal (blown fuse) of offset sensor (PS54) or transfer exposure lamp (TSL) was detected but no error signal (24V disconnection) is detected. The main body stops immediately to turn OFF the Rl1 (main).

14. MALFUNCTION CODE Estimated abnormal parts Printer control board (PRCB) ADU drive board /1 (ADJDB1) Loose connection

Printer control board (PRCB) ADU drive board /1 (ADJDB1) Loose connection ADU drive board /1 (ADJDB1) DC power supply /1 (DCPS1)

Centering sensor (PS54) Transfer exposure lamp (TSL) ADU lock solenoid (SD6) Reverse/exit solenoid (SD7) Thick paper assist solenoid (SD8)

SC93-08 Error detection signal (24V blown fuse) of PF drive board (PFUDB) was detected. Fan abnormality SC95-01 The EM signal is found abnormal a specified period of time after the ADU cooling fans /1 (FM14), /2 (FM15) and /3 (FM13), the sensor cooling fan (FM16) and the registration cooling fan (FM17) turn on. And the signal is still found abnormal a specified period of time after it turns on again after turning off, and the door close of the door open/close sensors /1 (PS1) and / 2 (PS2) and the PF door open/ close sensor (PS70) has been detected 10 times in a row.

PF drive board (PFUDB)

ADU drive board /1 (ADJDB1) ADU cooling fan /1 (FM14), / 2 (FM15), /3 (FM13) Sensor cooling fan (FM16) Registration cooling fan (FM17)

643

bizhub PRO 1050/1050P 1050e/1050eP

14. MALFUNCTION CODE

Field Service Ver3.0 Nov.2006

bizhub PRO 1050/1050P /1050e/1050eP

C. Function to detach defective sections For those abnormalities listed in the table below, defective units can be detached temporarily to use other control units. While detached, an error detection is not carried out on these detached units. There are 2 methods of setting for limited use. (1) User operation When an error code occurs, press the HELP key following the message on the LCD and then turn the power switch (SW2) OFF and ON. This allows you to use it temporarily until the main power switch (SW1) is OFF and ON (including an OFF/ON operation by the weekly timer) next time. (2) DIPSW setting Turning the main switch OFF and ON after setting the specified software DIPSW bit allows you to make a limited use of it until the bit setting is released next time (this requires the OFF/ON operation of the main power switch (SW1)). Classifi- Error code cation Main body SC18-10 SC18-11 SC18-12 SC18-13 SC18-20 SC18-21 SC18-22 SC18-23 PF SC18-30 SC18-31 SC18-32 SC18-33 SC18-40 SC18-41 SC18-42 SC18-43 SC18-50 SC18-51 SC18-52 SC18-53 Main body SC46-40 SC46-41 SC46-42 SC46-43 DF SC67-01 SC67-02 SC67-03 SC67-04 Paper lift motor /1 abnormality Tray /1 up abnormality 1 Tray /1 up abnormality 2 Tray /1 up abnormality 3 Paper lift motor /2 abnormality Tray /2 up abnormality 1 Tray /2 up abnormality 2 Tray /2 up abnormality 3 Paper lift motor /3 abnormality Tray /3 up abnormality 1 Tray /3 up abnormality 2 Tray /3 up abnormality 3 Paper lift motor /4 abnormality Tray /4 up abnormality 1 Tray /4 up abnormality 2 Tray /4 up abnormality 3 Paper lift motor /5 abnormality Tray /5 up abnormality 1 Tray /5 up abnormality 2 Tray /5 up abnormality 3 HDD initialization abnormality JOB RAM storage abnormality HDD periodic cleaning abnormality HDD access error Original registration abnormality Original conveyance abnormality Original reverse abnormality RADF control board abnormality DF mode unavailable (DF connection not recognized) DIPSW18-4 Paper feed in tray /1 is unavailable (The operation panel is displayed in hatching) Paper feed in tray /2 is unavailable (The control panel is displayed in hatching) Paper feed in tray /3 is unavailable (The control panel is displayed in hatching) Paper feed in tray /4 is unavailable (The control panel is displayed in hatching) Paper feed in tray /5 is unavailable (The control panel is displayed in hatching) The use of HDD is unavailable (not connected) DIPSW18-7 DIPSW20-4 DIPSW18-3 DIPSW18-2 DIPSW18-1 DIPSW18-0 Description Control while detached DIPSW

644

Field Service Ver3.0 Nov.2006 Classifi- Error code cation DF SC67-05 SC67-06 SC67-07 SC67-08 LS SC76-01 SC76-02 SC76-03 SC76-04 SC76-05 SC76-06 SC76-07 SC76-08 SC76-09 SC76-10 SC76-11 SC76-31 SC76-32 SC76-33 SC76-34 SC76-35 SC76-36 SC76-37 SC76-38 SC76-39 SC76-40 SC76-41 Cooling fan abnormality Original reverse abnormality Original reverse/exit abnormality Tray up/down abnormality Tandem (1st) LS stacker tray up down abnormality Tandem (1st) LS shift unit drive abnormality Tandem (1st) LS alignment plate drive abnormality Tandem (1st) LS grip drive abnormality Tandem (1st) LS stacker tray upper limit abnormality Tandem (1st) LS stacker tray lower limit abnormality Tandem (1st) LS paper cooling fan /Fr drive abnormality Tandem (1st) LS cooling fan drive abnormality Tandem (1st) LS paper cooling fan /Mi drive abnormality Tandem (1st) LS motor cooling fan drive abnormality Tandem (1st) LS paper cooling fan /Rr drive abnormality Tandem (2nd) LS stacker tray up down abnormality Tandem (2nd) LS shift unit drive abnormality Tandem (2nd) LS alignment plate drive abnormality Tandem (2nd) LS grip drive abnormality Tandem (2nd) LS stacker tray upper limit abnormality Tandem (2nd) LS stacker tray lower limit abnormality Tandem (2nd) LS paper cooling fan /Fr drive abnormality Tandem (2nd) LS cooling fan drive abnormality Tandem (2nd) LS paper cooling fan /Mi drive abnormality Tandem (2nd) LS motor cooling fan drive abnormality Tandem (2nd) LS paper cooling fan /Rr drive abnormality DF mode unavailable Description

14. MALFUNCTION CODE Control while detached DIPSW DIPSW18-4

(DF connection not recognized)

The use of the tandem (1st) LS is unavailable.

DIPSW33-06

The use of the tandem (2nd) LS is unavailable

DIPSW33-07

645

bizhub PRO 1050/1050P 1050e/1050eP

14. MALFUNCTION CODE

Field Service Ver3.0 Nov.2006 Description Control while detached The use of sorting and stapling functions is unavailable DIPSW DIPSW35-1

bizhub PRO 1050/1050P /1050e/1050eP

Classifi- Error code cation FS SC77-02 SC77-03 SC77-04 SC77-05 SC77-06 SC77-07 SC77-08 SC77-11 SC77-12 SC77-15 SC77-21 SC77-22 SC77-25 FD SC77-30 SC77-31 SC77-32 SC77-33 SC77-34 SC77-35 SC77-36 SC77-37 SC77-38 SC77-39 SC77-40 SC77-41 SC77-42 SC77-43 SC77-44 SD SC77-60

Tray up down drive abnormality Alignment drive abnormality Paper exit roller drive abnormality Paper exit opening drive abnormality Staple abnormality Staple rotation drive abnormality (skew rotation) Staple rotation abnormality (vertical rotation) Staple unit /Fr abnormality Staple unit /Rr abnormality Paper exit arm drive abnormality Rear stopper drive abnormality Stack assist drive abnormality Intermediate roller open/close drive abnormality 1st folding cam drive abnormality 2nd folding cam drive abnormality 3rd folding cam drive abnormality 2 holes punch drive abnormality 3 holes/4 holes punch drive abnormality Punch alignment plate drive abnormality Punch paper rear registration drive abnormality Main tray upper limit abnormality Main tray lower limit abnormality PI lift plate /Up up/down abnormality PI lift plate /Lw up/down abnormality Entrance conveyance drive abnormality Intermediate conveyance drive abnormality PI conveyance drive abnormality Paper exit conveyance drive abnormality Bundle exit drive abnormality

The use of staple is unavailable

DIPSW35-0

The use of sorting and stapling functions is unavailable

DIPSW35-1

The use of the folding function and the punch section is unavailable

DIPSW33-0

Main tray paper exit is unavailable The use of the PI section unavailable The use of the entire FD unavailable

DIPSW33-2

DIPSW33-3 DIPSW33-4

The use of the saddle stitching, multi center folding and trimmer unavailable

DIPSW34-0, 1, 3 DIPSW34-0, 1, 2, 3

SC77-61 SC77-62

Folding main scan alignment drive abnormality Folding sub scan alignment paper exit drive abnormality

The use of the saddle stitching, multi center folding, multi letter folding and trimmer unavailable

646

Field Service Ver3.0 Nov.2006 Classifi- Error code cation SD SC77-63 SC77-64 SC77-65 SC77-66 SC77-67 SC77-68 SC77-69 SC77-70 SC77-71 SC77-72 Saddle stitching alignment/Rt drive abnormality Bundle arm drive abnormality Bundle clip drive abnormality Bundle registration drive abnormality Overlap drive abnormality Folding main scan alignment /Rr drive abnormality Stapler movement drive abnormality Saddle stitching alignment /Lt drive abnormality Bundle press movement drive abnormality 1st folding blade drive abnormality Description

14. MALFUNCTION CODE Control while detached The use of the saddle stitching, multi center folding and trimmer unavailable DIPSW DIPSW34-0, 1, 3

The use of the saddle stitching, multi center folding, multi letter folding and trimmer unavailable The use of the saddle stitching, multi center folding and trimmer unavailable

DIPSW34-0, 1, 2, 3 DIPSW34-0, 1, 3

The use of the saddle stitching, multi center folding, multi letter folding and trimmer unavailable

DIPSW34-0, 1, 2, 3 DIPSW34-2 DIPSW34-0, 1, 3

SC77-73 SC77-74 SC77-75 SC77-76 SC77-77 SC77-78 SC77-79 SC77-80 SC77-81 SC77-82 SC77-83 SC77-84 SC77-86 SC77-87 SC77-88 SC77-89 SC77-90

2nd folding blade abnormality Clincher up down drive abnormality

The use of the multi center folding unavailable The use of the saddle stitching,

Saddle stitching press drive abnormality multi center folding and trimmer unavailable Bundle arm rotation drive abnormality Bundle press drive abnormality Bundle press stage up down drive abnormality Guide shaft drive abnormality Stapler /Rt drive abnormality Stapler /Lt drive abnormality Trimmer blade drive abnormality Trimmer press drive abnormality Bundle arm assist drive abnormality Horizontal conveyance drive abnormality Folding entrance drive abnormality Folding conveyance drive abnormality Bundle exit drive abnormality Folding sub scan alignment paper exit drive abnormality The use of the saddle stitching, multi The use of the coupling exit and subtray paper exit unavailable The use of the saddle stitching, multi center folding, multi letter folding and trimmer unavailable The use of the saddle stitching, multi The use of the saddle stitching, multi center folding, multi letter folding and trimmer unavailable The use of the trimmer unavailable The use of the saddle stitching and trimmer unavailable The use of the trimmer unavailable

DIPSW34-0, 3 DIPSW34-3 DIPSW34-0, DIPSW34-4 DIPSW34-0, 1, 2, 3 DIPSW34-0, DIPSW34-0, 1, 2, 3 DIPSW34-3

center folding and trimmer unavailable 1, 3

center folding and trimmer unavailable 1, 3

SC77-91

Scraps removal fan drive abnormality

647

bizhub PRO 1050/1050P 1050e/1050eP

14. MALFUNCTION CODE

Field Service Ver3.0 Nov.2006 Description Control while detached The use of the PB is unavailable DIPSW DIPSW35-5

bizhub PRO 1050/1050P /1050e/1050eP

Classifi- Error code cation PB SC78-01 SC78-02 SC78-04 SC78-05 SC78-06 SC78-07 SC78-08 SC78-09 SC78-10 SC78-11 SC78-12 SC78-13 SC78-14 SC78-15 SC78-16 SC78-18 SC78-19 SC78-20 SC78-21 SC78-22 SC78-23 SC78-24 SC78-25 SC78-26 SC78-27 SC78-28 SC78-30

Entrance conveyance drive abnormality Intermediate conveyance drive abnormality SC entrance conveyance drive abnormality SC switchback conveyance drive abnormality SC switchback roller release drive abnormality SC alignment drive abnomality SC paper detection conveyance drive abnormality SC roller release drive abnormality SC clamp entrance movement drive abnomality SC clamp entrance roller release drive abnormality Clamp alignment drive abnormality Clamp open/close drive abnormality Clamp rotation drive abnormality Glue tank movement drive abnormality Glue apply roller rotation drive abnormality Pellet supply arm drive abnormality Up/down cover paper alignment drive abnormality Up/down cover paper book paper exit drive abnormality Driven arm /Rt drive abnormality Driven arm /Lt drive abnormality Up/down cover paper conveyance drive abnormality Up/down cover paper/Fr up/down drive abnormality Up/down cover paper/Rr up/down drive abnormality Cover paper folding board /Rt drive abnormality Cover paper folding board /Lt drive abnormality Cover paper trimming cutter drive abnormality Carriage belt drive abnormality

Ejecting onto the sub tray is pos- DIPSW35-4 sible.

648

Field Service Ver3.0 Nov.2006 Classifi- Error code cation PB SC78-31 SC78-32 SC78-33 SC78-34 SC78-35 SC78-36 SC78-37 SC78-38 SC78-39 SC78-40 Carriage size movement drive abnormality Carriage up/down drive abnormality Book movement drive abnormality Book stopper drive abnormality Cover paper tray fan /1 drive abnomality Cover paper tray fan /2 drive abnomality Cover paper tray up/down drive abnomality Cover page conveyance drive abnormality Exhaust fan drive abnormality Warming-up abnormality Glue tank middle temperature abnormality SC78-41 SC78-42 Warming-up abnormality Glue tank low temperature abnormality Warming-up abnormality Glue apply roller temperature abnormality SC78-43 Glue supply abnormality Glue tank high temperature abnormallity SC78-44 Heater continuous energization abnormality Glue tank middle temperature abnormality SC78-45 Heater continuous energization abnormality Glue tank low temperature abnormality SC78-46 Heater continuous energization abnormality Glue apply roller temperature abnormality SC78-47 High temperature abnormality Glue apply roller temperature abnormality SC78-48 High temperature abnormality Glue tank high temperature abnormallity Description

14. MALFUNCTION CODE Control while detached DIPSW

Ejecting onto the sub tray is pos- DIPSW35-4 sible.

Paper feed from the PB is unavailable.

DIPSW35-3

Ejecting onto the sub tray is pos- DIPSW35-4 sible. The use of the PB is unavailable DIPSW35-5

649

bizhub PRO 1050/1050P 1050e/1050eP

14. MALFUNCTION CODE

Field Service Ver3.0 Nov.2006 Description Control while detached The use of the PB is unavailable DIPSW DIPSW35-5

bizhub PRO 1050/1050P /1050e/1050eP

Classifi- Error code cation PB SC78-49

High temperature abnormality Glue tank middle temperature abnormality

SC78-50 SC78-51

High temperature abnormality Glue tank low temperature abnormality High temperature abnormality Glue apply roller temperature abnormality

SC78-52

High temperature abnormality Glue tank high temperature abnormallity

SC78-53

High temperature abnormality Glue tank middle temperature abnormality

SC78-54 SC78-55

High temperature abnormality Glue tank low temperature abnormality High temperature abnormality Glue apply roller temperature abnormality

SC78-56

Low temperature abnormality Glue tank high temperature abnormallity

SC78-57

Low temperature abnormality Glue tank middle temperature abnormality

SC78-58 SC78-59

Low temperature abnormality Glue tank low temperature abnormality Low temperature abnormality Glue apply roller temperature abnormality

SC78-60

Low temperature abnormality Glue tank high temperature abnormallity

SC78-61

Low temperature abnormality Glue tank middle temperature abnormality

SC78-62

Low temperature abnormality Glue tank low temperature abnormality

650