Professional Documents
Culture Documents
EN
VI
RO
NM
E N TA L LY F R
IE
ND
LY
HFC R410A
TE
CT
IO N
DE L'ENVIRO N
NE
DESCRIPTION
Space PF Heat pumps and Cooling units are Air-Air packaged units of monobloc construction, horizontal compact, Roof-Top type. They are equipped with axial and centrifugal fans, air coils, hermetic scroll compressors and electronic control with microprocessor, components optimized for use with R-410A refrigerant. These units have been designed for air conditioning large areas of commercial or industrial use, allowing a quick installation and a reliable operation. A wide range of options will allow to solve numerous requirements of operation. All units are tested and checked at the factory.
RANGE
RPF - IPF Series: 1 cooling circuit, 1 compressor, 4 models: 90 / 120 / 160 / 180 RPF - IPF Series: 1 cooling circuit, 2 compressors, 3 models: 240 / 320 / 360 RPF - IPF Series: 2 cooling circuits, 2 compressors, 4 models: 420 / 485 / 540 / 600 RPF - IPF Series: 2 cooling circuits, 4 compressors, 2 models: 650 / 720 RPF - IPF Series: 4 cooling circuits, 4 compressors, 4 models: 840 / 960 / 1100 / 1200.
SERIES
Space RPF Series
Air-air packaged cooling units of horizontal compact construction roof-top type.
OPERATING LIMITS
Air inlet conditions Internal coil
Min. Max. Min. Max.
Cooling
14 C WB 22 C WB 12 C 48 C
Heating
10 C 27 C -10 C WB 15 C WB
External coil
With condensing pressure control, operating limit up to -10C. With overpowered axial fan, operating limit up to 52C.
AIR CONDITIONING - HEATING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 08.644 C - N 3500 F
Space PF
NT
PR
Space PF
UNITS COMPOSITION
Standard equipment
- Casing of galvanized metal plate with polyester lacquer, RAL 7024 grey graphite colour and white. Thermal insulation of 10 mm thickness with M1class. - Chassis support and access panels to the electrical panel, compressors, fans, etc. - Assemblies with mixing and free-cooling boxes: 1damper (non motorized): MT: External air intake with damper. 2 dampers (motorized): MS: External air intake with damper, fitted with return damper. 3 dampers (motorized): MK: Air extraction with overpressure damper. ME: Axial extractor fan with duct. MA: Axial return fan and air extraction with duct (to avoid recirculation). MC: Lower centrifugal return fan MC0 (radial) or in MC1 upper box. - External coil protection grille. - Coil of copper tubes and copper fins. - Coil of copper tubes and aluminium fins with polyurethane coating or blygold polual. - Hot water coil, with three-ways valve. - Optional electrical heaters, except for models 90 to 180 with upper discharge. - In periods with low outdoor temperatures, anti-frost protection of electrical panel with electric heater. - External circuit condensates drain pan in galvanized steel. - Internal circuit condensates drain pan in stainless steel. - Stop-drop in the internal air coil (included in models 1100 and 1200). Recommended for those cases in which is foreseen a high level of humidity in the air or when the air flow is high. - Stop-drop in the external air intake. - G4 gravimetric filter. - Opacimetric folded filters from F6 to F9 + G4 gravimetric filter. - Fouled filters differential pressostat. - Air flow control. - Condensation pressure control by pressostat. - Motor fans and compressor(s) line protection fuses (from model 90 to 960). - Power supply with neuter. - Soft starter of discharge fan, extend the commissioning time, for facilities with cloth ducts. - Natural or propane gas burner with modulating actuator. 2 versions: heatin support burner and nominal capacity. It is compulsory to use the optional Smoke detection with the gas burner, so that in case of fire, the control stops the burner. It is also recommended to use the optional of fouled filters detector. - Tropicalized unit. Includes varnish for the elements of electrical panel, internal and external tropicalized fans. - Standard preassembly mounts of galvanized steel plate and thermally isolated. They are adjustable for height (see drawings). There are two types: international and ERP France. - Rubber antivibratory supports.
External circuit
- Axial fan(s), 2 speeds, driven directly by motor. Leak-tight motor class F, IP55 and internal thermal protection. Dinamically balanced propellers and external protection grille. - Coils of copper tubes and aluminium fins.
Internal circuit
- Centrifugal fan, driven by belts and pulleys. Electric motor with tensor, class F, IP55 and internal thermal protection. One, two or three turbines of dual intake with curved blades forward. Greased-for-life ball bearings. - Regenerable air filters, mounted on frame. - Coils of copper tubes and aluminium fins. - Condensates drain pan. - Thermostatic expansion valve(s) with external equalization.
Cooling circuit
- Hermetic compressors scroll type, with acoustic insulation, mounted
on antivibratory supports. Control of phase equilibrium and rotation sense. - Crankcase heater (heat pumps). - Anti-acid dryer filters. - Four-ways reverse valve(s) (heat pump units).
Protections
High and low pressure pressostats. Control of compressor discharge temperature. Anti-return valve integrated in the compressor. Klixon in compressor. Main door switch. Motors with magnetothermal protection.
Electrical panel
- Complete electrical panel, totally wired. Panel cover isolated to avoid condensations. - Transformer for power supply without neuter. - IP55 protection - Grounding. - Motor fans and compressors contactors.
Options
- Casing thermal insulation of 18 mm thick. - Overpowered axial fans of external circuit. - EC electronic axial fans with condensing pressure control, adapting its turn speed to the installation requirements, reducing electrical power consumption, the sound level to partial load and improving the seasonal performance rate of the unit. - Internal circuit fan of high available pressure. - Discharge position and/or air return in the internal circuit. - Electronic control: GESCLIMA PRO.
AIR CONDITIONING - HEATING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 08.644 C - N 3500 F
90
21,9 8,1 2,9 22,3 6,7 3,5 8000
120
30,3 11,1 3,0 30,7 9,5 3,4 13000
160
38,4 13,6 3,0 38,6 12,3 3,3 19000
180
41,7 16,1 2,8 44,3 13,7 3,4 20000
240
59,6 20,3 3,3 62,6 19,5 3,4 22000 4 Axial
320
74,4 27,0 3,0 76,3 24,1 3,3 24000
360
83,9 31,0 2,9 85,9 30,5 2,9 30500
420
104,8 31,9 3,6 107,3 33,6 3,4 42000
485
115,2 36,5 3,4 117,3 37,6 3,3 42000
Heating capacities
Number D iameter (mm) Power (kW) Speed (r.p.m.) Nominal air flow (m3/h) 630 0,7 / 0,4 875 / 650 4000 8,3 6000 13,1
1 800 2,0 / 1,3 895 / 705 8700 9,2 9000 12,8 12000 13,5 Centrifugal 1/1 0,75 841 1,1 816 2,2 630 + 800 0,7 / 0,4 + 2,0 / 1,3 875 / 650 895 / 705 14300 11,7 15900 11,3
Avail. static pressure (mm.W.G.) Type Number / n turbines Power (kW) Speed (r.p.m.) Type Number of compressors
2,2
690
717
1 1 1
2 2 2
Compressor
Copeland 3MAF 32 cST, Danfoss POE 160 SZ, ICI Emkarate RL 32 CF, Mobil EAL Artic 22 CC 3 3,3 3,3 6,2 2 x 3,3 2 x 3,3 2 x 6,2 2 x 6,2 2 x 6,2
Voltage
400 V / III ph / 50 Hz (5%) 3 Wires + Ground 36 4,3 5,0 0,7 46,0 58 4,3 6,9 1,3 70,5 R-410A 1975 12,9 2400 1400 1675 621 14,0 2610 2115 1705 828 Diameter 1 1/4" 16,4 2610 2115 1705 895 18,5 2610 2115 2005 1050 32,6 4816 2205 1795 1695 33,0 4816 2205 1795 1659 70 5,6 9,0 1,3 85,9 72 5,6 9,0 1,3 87,9 87 8,6 6,9 1,3 103,8 102 8,6 6,9 1,3 118,8
Refrigerant
Dimensions Weight
Condensates draining
Cooling capacity for an indoor temperature of 27 C, 50 % RH (19 C WB) and 35 C of outdoor temperature. Heating capacity for an indoor temperature of 20 C and 6 C WB of outdoor temperature. Total power input by compressor(s) and motorfans in nominal conditions. Climate warming potential of one kg of greenhouse-effect fluored gas relative to one kilogram of carbon dioxide over a period of 100 years. In models 160 and 180 with upper discharge it is necessary to change the fan and it is also necessary to change to a 3 kW motor.
AIR CONDITIONING - HEATING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 08.644 C - N 3500 F
Space PF
Space PF
TECHNICAL CHARACTERISTICS
Space PF
Cooling capacity (kW)
540
127, 5 42, 4 3, 2 128, 1 43, 0 3, 1
3
600
141, 8 49,1 3, 1 142, 8 44, 6 3,4 42000
650
154, 1 50, 4 3, 3 155, 9 50,0 3, 3 55000 4
720
166, 4 57,5 3,2 169,8 57,1 3, 1 56000
840
192, 6 71,6 3,0 206, 9 71, 0 3,1 75000
960
212,9 84,6 2,8 233, 2 81, 8 3, 0 75000
1100
255,2 98,1 2,7 261,0 95, 9 3,0 112500 2
1200
276,6 112,8 2,6 286, 5 109, 0 2,9 112500
Cool i ng capaci ti es
Heati ng capaci ti es
Power input (kW) COP Performance Nominal air flow (m /h) Avail. static pressure(mm.W.G.) Type
42000
A xial 2 2 x 800 2 x 2, 0 / 1, 3 895 / 705 20400 12, 7 24000 12,7 2 x 630 + 2 x 800 2 x 0, 7 / 0, 4 + 2 x 2, 0 / 1, 3 875 / 650 895 / 705 27500 12,3 30000 14, 8 4 4 x 800 4 x 2, 0 / 1, 3 895 / 705 33000 17, 7 37000 19,2 6 6 x 800 6 x 2, 0 / 1, 3 895 / 705 42000 15, 1 46000 17, 9
Number Diameter (mm) Power (kW) Speed (r.p.m.) Nominal air flow (m3/h)
Avail. static pressure(mm.W.G.) Type Number / n turbines Power (kW) Speed (r.p.m.) Type Number of compressors
C entrif ugal 1/3 3 561 5,5 605 5,5 621 7,5 651 Scroll 2 2 2 4 4 4 11 729 11 760 18,5 858 22 918
Compressor
Copeland 3MAF 32 cST, Danfoss POE 160 SZ, ICI Emkarate RL 32 CF, Mobil EAL Artic 22 CC 2 x 6, 2 2 x 6, 2 4 x 3, 3 4 x 6, 2 4 x 6, 2 4 x 6, 2 4 x 6, 2 4 x 6, 2
Voltage
400 V / III ph / 50 Hz (5%) 3 Wires + Ground 144 11,2 14, 7 1,3 171,2 174 17,2 22, 0 1,3 214, 5 204 17,2 22,0 1,3 244, 5 232 25,8 37,0 1,3 296, 1 260 25,8 42,0 1,3 329,1
External fan(s) (A) Internal fan (A) Control (A) Total (A) Type
R-410A 1975 35, 0 4816 2205 1795 1732 35, 4 4816 2205 1795 1786 35, 0 4816 2205 2095 2071 41,2 4816 2205 2095 2249 44, 0 4816 2205 2095 2335 46,4 4816 2205 2095 2333 57, 2 6316 2205 2095 2803 58, 0 6316 2205 2095 2914
Refri gerant
Di mensi ons
Wei ght
(kg)
Condensates drai ni ng
Diameter 1 1/4"
Cooling capacity for an indoor temperature of 27 C, 50 % RH (19 C WB) and 35 C of outdoor temperature. Heating capacity for an indoor temperature of 21 C and 6 C WB of outdoor temperature. Total power input by compressor(s) and motorfans in nominal conditions. Climate warming potential of one kg of greenhouse-effect fluored gas relative to one kilogram of carbon dioxide over a period of 100 years.
AIR CONDITIONING - HEATING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 08.644 C - N 3500 F
M020
M021
M022
MT00
N
MT01
N
MT02
N
MT10
N
MT11
N
MT12
N
MT20
R N
MT21
R N
MT22
R N
MS00
N
MS01
N
MS02
N
MS10
N
MS11
N
MS12
N
MS20
R N
MS21
R N
MS22
R N
MK00
N
MK01
N
MK02
N
ME00
N
ME01
N
ME02
N
MA00
N
MA01
N
MA02
N
MC10
R E R
MC11
E
MC00
N
MC01
N
MC02
N N N
Designation
E I E E I
Mwxy
Discharge 0 = Standard 1 = Optional 2 = Optional 0 = Standard 1 = Optional 2 = Optional
Return
MRC10(*)
R E R
MRC11(*)
E
MRC00(*)
N
MRC01(*)
N
MRC02(*)
N N N
AIR CONDITIONING - HEATING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 08.644 C - N 3500 F
Space PF
M002
M010
M011
M012
Space PF
OPTIONS FOR EXTERNAL CIRCUIT
Electronic axial fan
Space PF Nomi nal ai r fl ow (m3/h) 90
8000 15 1
120
13000
160
19000
180
20000
240
22000 12,5
320
24000
360
30500
420
42000
485
42000
Max. avai l . stati c pressure (mm.W.G.) Number Di ameter Power Maxi mum speed Max. power i nput Space PF Nomi nal ai r fl ow (m3/h) (mm) (kW) (r.p.m.) (A )
2 800 2, 1 1100 3, 4 630 + 800 0, 9 + 2, 1 1000 1100 5, 4 2 x 800 2 x 2,1 1100 6,8
630 0, 9 1000 2
540
42000
600
42000
650
55000
720
56000 12, 5
840
75000
960
75000
1100
112500
1200
112500
Max. avai l . stati c pressure (mm.W.G.) Number Di ameter Power Maxi mum speed Max. power i nput (mm) (kW) (r.p.m.) (A )
2 2 x 800 2 x 2, 1 1100 6, 8 2 x 630 + 2 x 800 2 x 0, 9 + 2 x 2, 1 1000 / 1100 10,8
90 (m3/h) (mm.W.G.)
8000 12
120
13000
160
19000
180
20000
240
22000 7
320
24000
360
30500
420
42000
485
42000
540
42000
600
42000
650
55000 7
720
56000
840
75000
960
75000
1100
112500 5
1200
112500
10
AIR CONDITIONING - HEATING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 08.644 C - N 3500 F
90 (m3/h)
2000
120
3000 1
160
4350
180
4500
240
6000
320
7150
360
7950 2
420
9000
485
9100
(mm)
450 230 V / I p h / 50 Hz
0, 48 1350 2, 1
2 x 0, 48
4, 2
600
12000
650
13750
720
15000 3 450
840
16500
960
18500
1100
21000 4
1200
23000
(mm)
90 (m3/h)
4000
120
6000
160
8700
180
9000 2
240
12000
320
12400
360
12400
485
18200
(mm)
450 230 V / I p h / 50 Hz
2 x 0, 48 1350 4, 2
4 x 0, 64 1270 12
600
24000
650
27500 4
720
30000
840
30000
960
30000
1100
37500 5
1200
37500
(mm)
AIR CONDITIONING - HEATING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 08.644 C - N 3500 F
11
Space PF
Space PF
Lower radial centrifugal return fan (MC0 assembly)
Space PF Nomi nal ai r fl ow Avai l abl e stati c pressure Number Di ameter Power Speed Max. power i nput Space PF Nomi nal ai r fl ow Avai l abl e stati c pressure Number Di ameter Power Speed Max. power i nput (kW) (r.p.m.) (A )
4 x 500 2 x (2, 7 + 1, 4) 2 x 1700 / 2 x 1375 14, 6 1 x 500
90 (m3/h) (mm.W.G.)
4000
120
6000
160
8700
180
9000
240
12000 17
320
14300 10 2
360 14600 7
420 18000 21
4 4 x 500
485 18200 21
29
15
1
33
27
1 x 560 2, 3 1350 3, 6
2, 7 1700 4, 3
600 24000 17
650 27500 21 4
720 30000 12
840 33000 21
960 34600 12
1100 42000 11 5
1200 43500 8
90 (m3/h) (mm.W.G.)
4000 4, 7
120
6000 7
160
8700 10,2
180
9000 7,8 1/1
240
12000 7, 7
320
14300 6, 9
360
15900 7, 9
420
18000 7, 9 1/2
485
18200 6, 9
(kW) (r.p.m.) (A )
0, 37 548 1, 1
1, 1 667 2,7
1,5 555 3, 6
1, 5 564 3, 6
2, 2 464 5, 0
3 507 6, 9
4 540 9, 0
3 473 6, 9
3 476 6, 9
600
24000 7, 9
650
27500 8,3
720
30000 8, 7
840
33000 9,7 1/3
960
37000 9, 6
1100
42000 13
1200
46000 12
4 487 9, 0
7, 5 533 14,7
7, 5 570 14, 7
11 612 22,0
15 699 29, 0
15 729 29, 0
Note: Consult the performance curves of these fans on pages 101 to 115 of this brochure.
12