You are on page 1of 8

AS 3546—1996

Australian Standard
This is a free 7 page sample. Access the full version at http://infostore.saiglobal.com.

Wool— Method for measuring


average yellowness of raw wool
This Australian Standard was prepared by Committee TX/12, Testing of Wool. It was
approved on behalf of the Council of Standards Australia on 4 April 1996 and
published on 5 August 1996.

The following interests are represented on Committee TX/12:


Australian Council of Wool Exporters
Australian Wool Exchange
Australian Wool Processors Council
Australian Wool Research and Promotion Organisation
This is a free 7 page sample. Access the full version at http://infostore.saiglobal.com.

CSIRO—Division of Wool Technology


Department of Defence, Australia
Lincoln University, New Zealand
National Association of Testing Authorities, Australia
National Council of New Zealand Wool Interests
New Zealand Council of Wool Exporters
New Zealand Wool Board
New Zealand Wool Brokers Association
Telarc, New Zealand
Testing Interests, Australia
Testing Interests, New Zealand
University of New South Wales
Wool Council of Australia
Wool Research Organization of New Zealand
Wool Scourers and Carbonisers Association of Australia

Review of Australian Standards. To keep abreast of progress in industry, Australian Standards are subject
to periodic review and are kept up to date by the issue of amendments or new editi ons as necessary. It is
important therefore that Standards users ensure that they are in possession of the latest editi on, and any
amendments thereto.
Full detail s of all Australian Standards and related publi cati ons wil l be found in the Standards Australi a
Catalogue of Publications; this information is supplemented each month by the magazine ‘The Australian
Standard’, which subscribing members receive, and which gives details of new publi cati ons, new editi ons
and amendments, and of withdrawn Standards.
Suggesti ons for improvements to Australi an Standards, addressed to the head offi ce of Standards Australi a,
are welcomed. Notif ication of any inaccuracy or ambiguit y found in an Australi an Standard should be made
without delay in order that the matter may be investigated and appropriate action taken.

This Standard was issued in draft form for comment as DR 95048.


AS 3546—1996

Australian Standard
This is a free 7 page sample. Access the full version at http://infostore.saiglobal.com.

Wool— Method for measuring


average yellowness of raw wool

PUBLISHED BY STANDARDS AUSTRALIA


(STANDARDS ASSOCIATION OF AUSTRALIA)
1 THE CRESCENT, HOMEBUSH, NSW 2140
ISBN 0 7337 0554 5
AS 3546— 1996 2

PREFACE

This Standard was prepared by the Joint Standards Australia/Standards New Zealand
Committee TX/12 on Wool to supersede AS 3546 —1988 Wool — Method for the
measurement of average yellowness of greasy wool. It sets out a method to be used to
measure average yellowness of samples of raw wool prepared for mean fibre diameter
measurement in accordance with AS/NZS 1133 Wool— Determination by the airflow
method of the mean fibre diameter of core samples of raw wool. The method is not
suitable for identifying the contamination by individual coloured fibres.
This Standard is the result of a consensus among representatives on the Joint Committee
to produce it as an Australian Standard.
The revision of AS 3546 was needed to enable combination certificates to be calculated
and to allow ‘as is’ colour to be determined.
This is a free 7 page sample. Access the full version at http://infostore.saiglobal.com.

Because of the difficulties in defining preparation procedures for the measurement of both
lightness and yellowness of cleaned greasy wool, this Standard for measuring yellowness
only has been produced. The lightness value of wool is needed to calculate average
yellowness in combination certificates, but is not reported on individual test certificates.
However, it is hoped that further research work will resolve these difficulties and allow a
more complete specification of the colour of wool.
The method describes the preferred apparatus for the measurement. A statement on the
precision of the method is given.
This Standard is one of a series of Standards for the sampling and testing of wool.
The term ‘normative’ has been used in this Standard to define the application of the
appendix to which it applies. A ‘normative’ appendix is an integral part of a Standard.

 Copyri ght STANDARDS AUSTRALIA


Users of Standards are reminded that copyri ght subsists in all Standards Austr alia publi cati ons and software. Except where the
Copyri ght Act all ows and except where provided for below no publi cati ons or soft ware produced by Standards Australi a may be
reproduced, stored in a retr ieval system in any form or transmitt ed by any means without prior permission in writ ing from
Standards Australi a. Permission may be condit ional on an appropri ate royalt y payment. Requests for permission and information
on commercial software royalt ies should be directed to the head offi ce of Standards Austr alia.
Standards Austr alia wil l permit up to 10 percent of the technical content pages of a Standard to be copied for use
exclusively in-house by purchasers of the Standard without payment of a royalty or advice to Standards Austr alia.
Standards Austr alia wil l also permit the inclusion of its copyri ght material in computer soft ware programs for no royalty
payment provided such programs are used exclusively in-house by the creators of the programs.
Care should be taken to ensure that material used is fr om the curr ent edit ion of the Standard and that it is updated whenever the
Standard is amended or revised. The number and date of the Standard should therefore be clearly identif ied.
The use of materi al in print form or in computer software programs to be used commercially, with or without payment, or in
commercial contracts is subject to the payment of a royalty. This policy may be vari ed by Standards Austr alia at any ti me.
3 AS 3546 — 1996

CONTENTS
Page

FOREWORD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

1 SCOPE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
2 OBJECTIVE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3 APPLICATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
4 REFERENCED DOCUMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
5 PRINCIPLE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
6 DEFINITIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
7 APPARATUS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
This is a free 7 page sample. Access the full version at http://infostore.saiglobal.com.

8 PREPARATION OF TEST SPECIMENS . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6


9 CALIBRATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
10 MEASUREMENT OF TRISTIMULUS VALUES . . . . . . . . . . . . . . . . . . . . . . 8
11 PRECISION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
12 COMBINATION OF YELLOWNESS MEASUREMENTS . . . . . . . . . . . . . . . . 9
13 REPORT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

APPENDICES
A SPECIMEN HOLDER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
B CALIBRATION OF COLORIMETERS AND SPECTROCOLORIMETERS . . 14
C CALIBRATION OF SPECTROPHOTOMETERS . . . . . . . . . . . . . . . . . . . . . 16

Originated as AS 3546 — 1988.


Second editi on — 1996.
AS 3546— 1996 4

FOREWORD

It is difficult for the human eye to make reliable quantitative assessments of colour and
there can be considerable variability in the degree of accuracy with which observers detect
differences in colours. Moreover, colour differences which are easy to see when the
objects are side-by-side, are very much harder to assess when the objects are separated by
time or distance. An objective measurement of colour is therefore desirable.
A complete measurement of the colour of an opaque material such as wool is obtained by
measuring the proportion of light reflected from its surface throughout the visible
spectrum. It is, however, possible to obtain useful information by measuring the reflection
in the red, green and blue regions. Under the conditions specified by the International
Commission of Illumination (C.I.E.)*, these three readings are referred to as the
tristimulus values X (red), Y (green) and Z (blue). The values provide sufficient
information to describe colour for the specified light source and viewing conditions. They
This is a free 7 page sample. Access the full version at http://infostore.saiglobal.com.

can be used directly, or they can be transformed, to provide information concerning


particular aspects of colour.
The colour of wool is influenced, not only by its inherent colour, but also by the grease,
suint, dirt, vegetable matter and other impurities present. The colour of the cleaned wool
is usually of interest since most of these impurities are removed during processing and
generally do not affect the colour of the final product. This Standard relates to a
measurement on the laboratory sample prepared for mean fibre diameter measurement
according to AS/NZS 1133. For greasy wool a core sample is scoured and carded to
remove most of the contaminants that will ultimately be removed during processing.
The base colour measurement of either greasy wool core samples or commercially scoured
wool is an attempt to determine the inherent colour of the wool. The ‘as is’ colour (as
defined) when compared with base colour, is an indicator of the effectiveness of
commercial scouring.
In this Standard only the aspect of yellowness is addressed, although in combination
certificates, both the Y and Z values of individual components are needed. Y represents the
lightness of the sample. Yellowness relates to the relative intensities of reflectance in the
green and blue regions of the spectrum. The yellowness index given by this Standard is
derived from the tristimulus values Y and Z as Y-Z. As an illustration of the range of this
parameter for wool, the following values are given:
Colour description Y-Z units
Very white -2
White 0
Creamy 3
Canary yellow stain 12
Wool colours which are not well identified solely by yellowness measurement include
brown, black and green.

* CIE — Commission Internationale de l’Eclairage. See CIE Publication No 15 (E— 1.3.1) 1971 .
5 AS 3546 — 1996

STANDARDS AUSTRALIA

Australian Standard
Wool— Method for measuring average yellowness of raw wool

1 SCOPE This Standard sets out a method for measuring the average yellowness of a
sample of raw wool cores taken from a lot by the method described in AS 1980. The
procedures to be used to clean and prepare the sample prior to measurement are those set
out in AS/NZS 1133 and are not described in this Standard.

2 OBJECTIVE The objective of this Standard is to provide the wool industry with an
average yellowness measurement of greasy or scoured wool to indicate its processing
This is a free 7 page sample. Access the full version at http://infostore.saiglobal.com.

potential.

3 APPLICATION The method is applicable to the determination of the average


yellowness of greasy wool prepared for mean fibre diameter measurement in accordance
with AS/NZS 1133. This is the base yellowness result after cleaning, drying and carding.
The method may also be used to determine the ‘as is’ yellowness of commercially scoured
wool which may have been dried for a condition test in accordance with IWTO-33.
Preparation procedures (e.g. drying and exposure to UV light) are known to influence
wool colour.
The method is not suitable for the detection of contamination by pigmented, urine-stained
or coloured wools, e.g. brown, black or green. The method is suitable for measuring
colour in scoured wool containing urine-stained fibres.

4 REFERENCED DOCUMENTS The following documents are referred to in this


Standard:
AS
1980 Wool —Core sampling of raw wool in bales
2001 Methods of test for textiles
2001.1 Method 1: Conditioning procedures
AS/NZS
1133 Wool —Determination by the airflow method of the mean fibre diameter of core
samples of raw wool
IWTO
33 Method for the determination of oven-dry mass and calculated invoice mass of
scoured and carbonised wool

5 PRINCIPLE Test specimens are drawn from the prepared sample and arranged so as
to present a flat surface to the measuring instrument. The CIE tristimulus values Y and Z
are measured, and the yellowness is reported as Y − Z.

6 DEFINITIONS For the purpose of this Standard, the definitions below apply.
6.1 ‘As is’ colour — the colour of the wool sample, roving, top, scoured or carbonized
product, as received at the laboratory.

COPYRIGHT
This is a free preview. Purchase the entire publication at the link below:

AS 3546-1996, Wool - Method for measuring


average yellowness of raw wool
This is a free 7 page sample. Access the full version at http://infostore.saiglobal.com.

Looking for additional Standards? Visit SAI Global Infostore


Subscribe to our Free Newsletters about Australian Standards® in Legislation; ISO, IEC, BSI and more
Do you need to Manage Standards Collections Online?
Learn about LexConnect, All Jurisdictions, Standards referenced in Australian legislation
Do you want to know when a Standard has changed?
Want to become an SAI Global Standards Sales Affiliate?

Learn about other SAI Global Services:

LOGICOM Military Parts and Supplier Database


Metals Infobase Database of Metal Grades, Standards and Manufacturers
Materials Infobase Database of Materials, Standards and Suppliers
Database of European Law, CELEX and Court Decisions

Need to speak with a Customer Service Representative - Contact Us

You might also like