You are on page 1of 14

Information

GeoCENTREX Call Pick Up (CPU)


A30828-X1150-C304-1-7629

Call Pick Up (CPU)

Information GeoCENTREX

Trademarks: All designations used in this document can be trademarks, the use of which by third parties for their own purposes could violate the rights of their owners.

Copyright (C) Siemens AG 2000


Issued by the Information and Communication Networks Group Hofmannstrae 51 D-81359 Mnchen Technical modifications possible. Technical specifications and features are binding only insofar as they are specifically and expressly agreed upon in a written contract.

A30828-X1150-C304-1-7629

Information GeoCENTREX

Call Pick Up (CPU)

This document consists of a total of 14 pages. All pages are issue 1.

Contents
1 2 3 3.1 3.2 3.3 4 5 6 Definition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Mode of operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Subscriber controlled input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Analog. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ISDN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Legend . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 11 12 12

Call charge registration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Administration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

A30828-X1150-C304-1-7629

Call Pick Up (CPU)

Information GeoCENTREX

A30828-X1150-C304-1-7629

Information GeoCENTREX

Call Pick Up (CPU)

1 Denition
The feature Call Pick Up (CPU) allows a GeoCENTREX subscriber to answer calls that are intended for other lines in the local GeoCENTREX group but cannot be answered there (e.g. because the called party is absent).

Network node

Feature code (+ directory number)

GeoCENTREX group

4711

4712

Operator benefits higher call completion rate and therefore increased revenue from call charges Subscriber benefits pickup of specific calls intended for other subscribers calls can easily be answered from a different telephone, e.g. if the called subscriber happens to be absent Availability Analog Subscriber GeoCENTREX subscriber Use and effect Calling subscriber CPU use CPU effect Interactions For interaction with other features, see Feature Interactions. ----Called subscriber X X --X ISDN --X

A30828-X1150-C304-1-7629

Call Pick Up (CPU)

Information GeoCENTREX

2 Mode of operation
For GeoCENTREX the feature Call Pick Up (CPU) can be created in different variants: Common Call Pick Up (CCPU) Group Call Pick Up (GCPU) Direct Call Pick Up (DCPU) Customer Premises Equipment Call Pick Up (CPECPU) The feature variants can be assigned simultaneously to a GeoCENTREX subscriber and used simultaneously. Common Call Pick Up Common Call Pick Up gives access to the features Group Call Pick Up and Direct Call Pick Up via the same feature code. The features are called according to the digits dialed: Feature code for CCPU Group Call Pick Up (GCPU) Feature code for CCPU + GeoCENTREX internal number for call pickup Direct Call Pick Up (DCPU) Group Call Pick Up For group call pickup, call pickup groups are created in the local GeoCENTREX group. GeoCENTREX subscribers with authorization for GCPU can answer calls intended for other subscribers in the call pickup group. More than one call pickup group can be formed in a local GeoCentrex group, but a subscriber line can only belong to one call pickup group. The number of call pickup groups per GeoCentrex group is not limited. The maximum number of call pickup groups per EWSD network node is 65535. 4095 call pickup groups can be formed per GeoCentrex group. The number of subscriber lines per CPU group is not limited. For one call pickup group, up to eight calls can be queued simultaneously for call pickup. A call that has already been refused for call pickup (e.g. due to other subscriber restrictions) can be picked up by another subscriber in the call pickup group. To pick up a call within the call pickup group, the subscriber dials a feature code (Fig. 2.1). If there are several unanswered calls to GeoCENTREX subscriber lines in the call pickup group at the same time, the subscriber automatically picks up the call which has been waiting longest.

A30828-X1150-C304-1-7629

Information GeoCENTREX

Call Pick Up (CPU)

1. Call to susbscriber 4712

Network node

GeoCENTREX group Call pickup group

Directory number 4712

4711

4712

2. Call pickup by subscriber 4711

GeoCENTREX group Call pickup group Feature code 4711

4712

3. Connection after call pickup

GeoCENTREX group Call pickup group

4711

4712

Fig. 2.1

Group Call Pick Up (GCPU)

A30828-X1150-C304-1-7629

Call Pick Up (CPU)

Information GeoCENTREX

Direct Call Pick Up This feature variant permits call pickup in the local GeoCENTREX group. GeoCENTREX subscribers with authorization for DCPU can divert calls intended for other subscribers in the GeoCENTREX group. To pick up a call, the subscriber dials a feature code and the GeoCENTREX number of the called line. When the EWSD receives the feature code for DCPU, it first sends a dial tone again to the GeoCENTREX subscriber who initiated call pickup (Fig. 2.2). This subscriber then dials the extension number of the line from which the call is to be picked up. EWSD then sets up the connection between the subscriber initiating direct call pickup and the calling subscriber. 1. Call to subscriber 4712 Network node GeoCENTREX group

4711 Directory number 4712 4712 2. Initiation of call pickup by subscriber 4711

GeoCENTREX group Feature code Dial tone 4711 Directory number 4712 4712

3. Connection after call pickup

GeoCENTREX group

4711

4712 Fig. 2.2 Direct Call Pick Up (DCPU)

A30828-X1150-C304-1-7629

Information GeoCENTREX

Call Pick Up (CPU)

Customer Premises Equipment Call Pick Up This feature variant permits call pickup in the local GeoCENTREX group. GeoCENTREX subscribers with the authorization for CPECPU can pick up calls addressed to customer premises equipment (e.g. a pager) in the GeoCENTREX group. To pick up calls the subscriber dials a feature code (Fig. 2.3). 1. Call to Pager 4712 Network node Directory number 4712 GeoCENTREX group

4711

Pager directory number 4712 2. Call pickup by subscriber 4711 Feature code GeoCENTREX group

4711

Pager directory number 4712

3. Connection after call pickup

GeoCENTREX group

4711

Pager directory number 4712 Fig. 2.3 Customer Premises Equipment Call Pick Up (CPECPU)

A30828-X1150-C304-1-7629

Call Pick Up (CPU)

Information GeoCENTREX

Capacity The percentages indicate the number of authorized subscribers for the feature within the network node and their simultaneous application. Analog Authorization GeoCENTREX subscriber 100% Use 100% ISDN Authorization 100% Use 100%

3 Subscriber controlled input


The feature can be used by subscriber controlled input. For the subscriber procedure, see: Analog subscriber ISDN subscriber Subscriber controlled input functions Signaling method Analog Pulse Activate Deactivate Enter data Delete data Enter data and activate Delete data and deactivate Activate with/without data Feature use Status request Data request Status request with/without data Access code The access code for subscriber controlled input consists of a maximum of 5 characters. It can be formed from the symbols 5 , # and the service code (SC) with the digits 0 ... 9. The operator can specify the character strings for the access code. --------------X ------DTMF --------------X ------ISDN Keypad --------------X ------Funct. -----------------------

10

A30828-X1150-C304-1-7629

Information GeoCENTREX

Call Pick Up (CPU)

Differences by pulse dialing The selected digits are not obligatory; other digits can be input (depending on the existing numbering plan). 1111 at the beginning of an input in place of 5 1112 at the beginning of an input in place of # 1113 at the beginning of an input in place of 5 # 5 as a disconnecting signal after the service code is not relevant # after the subscriber controlled input is not relevant Acknowledgments after subscriber controlled input The tones, and announcements and display texts are examples and can be administrated by the operator. The display texts can be changed to suit individual projects. The subscriber controlled input can be acknowledged by: Tones ringing tone acceptance tone subscriber busy tone or number unobtainable tone (NU) Announcements subscriber controlled input successful subscriber controlled input unsuccessful feature is already activated feature is not activated feature is not available wrong input Display texts (only in ISDN) wrong input not authorized request rejected successful unsuccessful not available

3.1

Analog
Feature use Group Call Pick Up (GCPU) Start Connection Direct Call Pick Up (DCPU) Start GeoCENTREX DN Connection DT DT A-C SC CXDN DT A-C SC

A30828-X1150-C304-1-7629

11

Call Pick Up (CPU)

Information GeoCENTREX

Customer Premises Equipment Call Pick Up (CPECPU) Start Connection DT A-C SC

3.2

ISDN
For inputs, see subscriber procedure Analog.

3.3

Legend
Introduces activation from terminal or introduces input from terminal or used as separator Enter ... Lift handset A-C CXDN DT SC Connection between calling subscriber (A) and subscriber (C) to whom the call is forwarded GeoCENTREX directory number Dial tone Service code

4 Call charge registration


Call charge registration is possible with: Automatic Message Accounting with Individual Call Charge Registration Pulse Metering Message Detail Recording (MDR) for GeoCENTREX Automatic Message Accounting with Individual Call Charge Registration (AMA) and Pulse Metering can be combined. One or more call charge pulses can be generated for Pulse Metering. Call charges for connections Call charges for connections are assigned as follows: the calling subscriber pays the charges for the connection up to the called subscriber

12

A30828-X1150-C304-1-7629

Information GeoCENTREX

Call Pick Up (CPU)

5 Administration
The operator can perform all administration functions on the NetManager by means of user-friendly applications or MML commands. Feature authorization The network operator assigns authorization for the feature when requested by the subscriber. Subscriber access types The feature can be used with the following types of subscriber access: Type Subscriber Analog Main station Basic access PBX PBX with BA and/or PA PBX line PBX line with Direct Dialing In (DDI) PBX line, connected like a subscriber Coinbox Emergency call station MLHG line Basic attendant console MAC attendant console System administration The following feature data can be administrated in the network node: recording by means of trafc measurement For more information, please refer to OMN:EXCH-SY. GeoCENTREX administration For more information, please refer to OMN:EXCH-CTX. For more information, please refer to OMN:EXCH-CTX Common Call Pick Up, Procedure CCPU Group Call Pick Up, Procedure GCPU Direct Call Pick Up, Procedure DCPU Customer Premises Equipment Call Pick Up, Procedure CPECPU ------------------------ISDN ------------------------GeoCENTREX Analog X --X --X X ------X X --ISDN --X --X X X ------X X X

A30828-X1150-C304-1-7629

13

Call Pick Up (CPU)

Information GeoCENTREX

6 Requirements
Hardware No special hardware is needed. Signaling Subscriber signaling Analog Dual-tone multi-frequency (DTMF) Pulse dialing ISDN Digital subscriber signaling system no.1 (DSS1) Subscriber interfaces The following interfaces for subscriber access can be used: DLU V5.1 interface V5.2 interface

14

A30828-X1150-C304-1-7629

You might also like