An Angular Trapezoidal Profile Sheet

Rigidity

Strength

Light weight

Design Flexibility

Maintenance Free

Anti Capillary Effect Simple Low Cost Fixing

Architecturally Attractive

SAFINTRA
world class roofing

Long Spanning Capabilities

Weather Ability & Durability Fully Trained Installation Teams

SAFINTRA
world class roofing

Product Description & Features


Comax 1000 is an angular trapezoidal fluted profile sheet. Its bold appearance makes it both attractive and practical. It has become the most popular sheeting used in the construction of commercial and industrial buildings. The number "1000" signifies the sheets effective cover width. The general shape and appearance of the trapezoidal flutes ensure that Comax 1000 is totally acceptable for use as roof and wall cladding. The deep and broad flutes of Comax 1000 type sheeting ensures excellent drainage characteristics. Comax 1000 is designed to provide the most advantageous load/span characteristics. Comax 1000 offers the end user stiffening ribs in the sheet which help to remove oil canning from the broad flute. Comax 1000 can be factory cranked, curved and bullnosed to a wide range of radii. For further details contact our Technical Department.
200
29

35

1000 mm cover width

All Dimensions in the above drawing are in mm

Dimensions
Profile Comax 1000 Cover Width* 1000 mm Crest 35 mm Pitch 200 mm Sheet Width 1060 mm

Sample Specification & Installation


The sheeting shall be Comax 1000 type profile as manufactured by Safintra Roofing. The profile shall be roll-formed with 6 trapezoidal ribs at 200 mm, centers with a net cover of 1000 mm. The rib height shall be 35 mm and shall be fixed in accordance with the manufacturer's recommendations. Safintra 0.50 mm thick, AZ 150 or Z 120, PPGI / PPGL Comax 1000 Profile Roof Sheeting, fixed to intermediate steel purlins at 1900 mm centers and to ridge and eaves purlins at 1650 centers, with 12 x 65 mm long class 3 metal self drilling screws at every second crest intermediate purlins and every crest eaves purlins side laps to be stiched at 500 mm centers between purlins all in accordance with manufacturers recommendations. When using Comax 1000 sheeting the recommended minimum pitch for roof slopes in excess of 15 m is 7.5 and for slopes less than 15 m is 5 Comax 1000 sheeting can be ordered in any length, subject to transport limitations, up to 13.2 m. Longer lengths require special transport arrangements.

* We sell all our profiles on cover width basis

Material Options
Galvanised / PPGI Z 120 245 / 345 Mpa Z 180 245 / 345 Mpa Z 275 245 / 345 Mpa Galvalume / PPGL AZ 70 300 / 550 Mpa AZ 100 300 / 550 Mpa AZ 150 300 / 550 Mpa Aluminium Mill Finish / Stucco Embossed Colour Coated Gauge (mm) 0.40 to 0.80

Gauge (mm) 0.40 to 0.80

Gauge (mm) 0.60 to 1.20

A length variation range of 5.0 mm, and width tolerance of 3.0 mm is permissible.

Purlin Spacings (mm)


Total Coated Thickness Type of Span Roofs Single Span End Span Internal; Double Span Cantilever (Unstffiened) Cantilever (Stiffened) Side Cladding Single Span End Span Internal Span Cantilever 2100 2400 2600 300 2100 2400 2600 300 2300 2600 2700 400 2300 2600 2700 400 2500 2650 2900 450 1650 1700 1900 150 300 1650 1700 1900 150 300 1750 1900 2100 180 350 1750 1900 2100 180 350 2200 2250 2600 200 400 0.47 mm 0.50 mm 0.55 mm 0.60 mm 0.80 mm

Fixing Procedure
The recommended roof fitting method for Comax 1000 is as shown in the figure below.
DIRECTION OF SHEET LAYING DIRECTION OF PREVAILING WEATHER

2nd Sheet 1st Sheet

3rd Sheet

Lay each run of sheets in turn from bottom to top before moving onto the next run as depicted below. Similar procedure for wall cladding too.

Purlin Spacings are dependant on both downward loading and negative suction loading caused by wind. Your engineer should be consulted to calculate your load (kN/m2) for your particular application.

CORPORATE OFFICE
Safintra Roofing (India) Limited Sultania House, Ground Floor, 18 Subhash Road, Vile Parle (East), Mumbai 400057, India. t : +91 22 4248 9450 f : +91 22 4248 9460 info@safintra.in www.safintra.in
Note : When reading the contents of this brochures, please keep in mind that the contents of this booklet are provided for the sole purpose of supplying information and are not intended as warranties or representations about the quality of the products. Furthermore, please note that the contents of this booklet are subject to change without prior notice.