SR 114H Standard - SR 114E Enhanced

Fire Resistant Cables

BS 5839-1 BS 7629-1 BS 6387 BS 8434-1/2 BS 6425 BS 7622 EN 50200

World-wide recognized high quality cables

Firecel SR114 are used in: Data Communication Centres Control Rooms Shopping Centres Hotels Theatres Cinemas Airports Underground Stations

Tunnels Traffic Control Centres Public Address System Marine and Offshore Fire Fighting Systems

The images below show some relevant installations equipped with Firecel cables.

1 2 3 4 5 6

Park Tower - Dubai Tupras Izmir Refinery - Turkey Tsing Ma Bridge - Hong Kong Financial Center - Abu Dhabi Emerald Palace - Palm Jumeirah - Dubai Airport Terminal 3 - Dubai

7 8 9 10 11 12

Combined-Cycle Power Plant Komotini - Greece Atlantis Hotel - Palm Jumeirah - Dubai New Delhi Metro - India Scottish Exhibition & Conference Centre Glasgow - UK Reebok Stadium - Bolton - UK Rose Rotana Tower - Dubai

Assessed to ISO 9001: 2000 Certificate number 217

Quality System Certification

Product Certificates No.217f / 217g assessed to BS 7629-1 and BS 5839-1: 2002

Product Certification

...tested and certified by our Fire Laboratory

In order to study new cables, new constructions, verify and certify the required performances, Cavicel has now a new well equipped Fire Laboratory. All Firecel cables can be fully tested according to international standards related to behaviour under fire condition. All test reports are registered in our files and, if required, cables can be supplied with Test Reports and Declaration of Compliance. The pictures below are taken in Cavicel Fire Laboratory and show some tests performed in our laboratory.

1 2 3 4

Resistance to fire alone BS 6387 Cat. C, IEC 60331, CEI 20-36 Resistance to fire with mechanical shock BS 6387 Cat. X Y Z Resistance to fire with water spray BS 6387 Cat. W Flame retardant test on single wire CEI 20-35/1, IEC 60332-1, BS 4066 part 1

5 6 7 8

Flame retardant test on bunched cables IEC 60332-3, BS 4066: part 3 Cavicel Fire Laboratory Smoke density test IEC 61034-2, BS 6724, CEI 20-37/3, BS 7622, EN 50268-1 Resistance to fire, mechanical shock and water - BS 5839-1, BS 8434

9 & 10 IEC 60754 part 1-2, BS 6425 part 1-2,


EN 50267/2-1 and 2-2

Test on gas evolved during combustion

11

Ongoing fire test

For more information about Fire Tests see our catalogue Nr. 103.

Requirements for Circuit Integrity

Features and Advantages


Flexible
Very flexible construction that makes the installation easier in all conditions.

Standard Enhanced Cables


BS 5839-1 : 2002 Fire Detection and Fire Alarm Systems for Buildings
Part 1: code of practice for system design, installation, commissioning and maintenance Par. 26 Cables, wiring and other interconnections
Recommendation for two levels of fire resistance: Standard for general use

LSZH (Low Smoke Zero Halogen) Construction


Combustion gases with very low toxicity, low smoke emission, and no corrosive gas, for the safeguard of human life and electronic equipment.

Flame retardant
Limiting the spread of the fire along the cable run, flame barriers can be avoided or reduced.

Protected against electrostatic noise


Cable is fully screened and conductors are twisted.

BS 5839-1 : 2002 recommends enhanced fire resistant cables for the following applications:
in unsprinklered buildings (or parts of buildings) in which the fire strategy involves evacuation of occupants in four or more phases; in unsprinklered buildings of greater than 30 m in height; in unsprinklered premises and sites in which a fire in one area could affect cables of critical signal paths associated with areas remote from fire, in which it is envisaged people will remain in occupation during the course of the fire; in any other buildings in which the designer, specifier or regulatory authority, on the basis of a fire risk assessment that takes fire engineering considerations into account, considers that the use of enhanced fire resisting cables is necessary. For more information we recommend to consult BS 5839-1 par. 26.

Moisture Resistant
No special terminations are required to prevent moisture absorption. It can be installed in damp environments.

Firecel SR 114H
EN 50200 PH30 Temperature: 830 C Flame and shock for 30 min. BS 8434-1: 2003 Temperature: 830 C Flame and shock for 15 min. + flame, shock and water for 15 min. Enhanced when cables might need to operate correctly during a fire for periods in excess of those normally required for single phase evacuation of building

Suitable for data transmission


Twisting of conductors make the cable suitable for clear data transmission.

Low cost installation


No special tools and special training are neccessary.A cheap and effective cable stripper is available to simplify installation. Easy to handle.

Quality Assurance
In order to satisfy QA requirements, traceability is assured by batch number printed on outer jacket.All reels have the evidence of testing.

Firecel SR 114E
EN 50200 PH120 Temperature: 830 C Flame and shock for 120 min. BS 8434-2: 2003 Temperature: 930 C Flame and shock for 60 min. + flame, shock and water for 60 min.

Current Ratings and Voltage Drop


installation method: clipped direct 1 two-core cable voltage drop xAxm cos = 1 mV 45 30 18 11 1 three/four-core cable voltage drop xAxm cos = 1 mV 39 26 15 10 1 two-core cable voltage drop xAxm cos = 1 mV 45 30 18 11

Cable Installation
Ambient Temperature
Firecel cables are easy to install also at temperature as low as 10 C. Storage temperature: 40 C to +80 C.
voltage drop xAxm cos = 1 mV 39 26 15 10

installation method: in conduit or in cable tray 1 three/four-core cable

Size of conductor (sqmm) 1.0 1.5 2.5 4.0

current rating A 19 24 33 45

current rating A 17 22 30 40

current rating A 17 22 30 40

current rating A 15 19.5 26 35

Bending Radius
Minimum 6times the nominal diameter of the cable.

1 Conductor operating temperature: 90 C; Ambient temperature: 30 C.

Installation
Cable is easy to handle and easy to install without special tools. Cable can be fixed direct to a surface using LSZH coated copper P clips, available together with cables.Plastic clips must not be used. Cable can also be installed in cable tray or in conduits, or direct buried in plaster. Suitable for outdoor installation too, in appropriate protected environments.

Rating Factors
Ambient temp. (C) Rating factor For grouping Number of cables Rating factor 2 3 4 5 6 8 10 12 14 16 18 20 0.80 0.70 0.65 0.60 0.57 0.52 0.48 0.45 0.43 0.41 0.39 0.38 25 1.04 30 1.00 35 0.95 40 0.90 45 0.85 50 0.80 55 0.74 60 0.67 65 0.60

Colours
Insulation
2 core + E 3 core + E 4 core + E 7 cores* 12 cores* 19 cores* blue brown blue centre 1st layer centre 1st layer centre 1st layer 2nd layer brown black brown brown brown brown brown brown brown brown black black 4 white 10 white black black black 4 white white 7 white grey black grey

Glands
For standard installation, general purpose nylon glands can be used. In explosion proof area suitable proof glands can be used with armoured cables.

Jacket
white / red / orange / black. Different colours upon request.

*on request the cores can be identified by printed numbers.

Armouring
Firecel cables can be supplied with:

SWA

Steel Wire Armour

SWB

Steel Wire Braid

Available colours: white/red.


Size

Nylon Gland
Ref.

Nylon Locknut
Packed

Packed Ref.

10 mm 16 mm 20 mm 25 mm 32 mm

MP10 MP16 MP20 MP25 MP32

100 100 100 100 100

ML10 ML16 ML20 ML25 ML32

100 100 100 100 100

FIRECEL SR114H is the long and well established CAVICEL fire resistant cable in the market, since many years. These cables are third party approved by LPCB which certify that FIRECEL SR114H cables have complied with the requirements of the following: BS 7629-1:2008 - 300/500 V fire resistant electric cables having low emission of smoke and corrosive gases when affected by fire - Multicore cables; Standard fire resistant cables as described in Clause 26.2d) of BS 5839-1:2002 - Fire detection and alarm systems for buildings. Code of practice for system design, installation, commissioning and maintenance; and achieved: Class PH30 when tested in accordance with BS EN 50200 - Method of test for resistance to fire of unprotected small cables for use in emergency circuits.

Electrical Characteristics
Voltage rating Temperature rating - for insulated conductors only Cross section (sq mm) Conductor resistance ( / km at 20 C) Insulation resistance (M x km at 20 C) Nominal Capacitance (pF / m) - core/core - core/screen 100 170 110 190 130 220 160 270 1 18.1 300 single or three phase circuit up to 300/500 V r.m.s. or up to 750 V d.c. circuit 40 +90 C max +200 C 1.5 12.1 300 2.5 7.41 300 4 4.61 300

Physical Characteristics
Nr. of conductors x section (sqmm) 2 x 1.0 3 x 1.0 Size of cond. (nr./mm) 1/1.13 1/1.13 1/1.13 1/1.38 1/1.38 1/1.38 1/1.75 1/1.75 1/1.75 7/0.53 7/0.53 7/0.53 7/0.67 7/0.67 7/0.67 7/0.85 7/0.85 7/0.85 1/1.13 1/1.38 1/1.13 1/1.38 1/1.13 1/1.38 Size of earth wire (nr./mm) 1/1.13 1/1.13 1/1.13 1/1.38 1/1.38 1/1.38 1/1.75 1/1.75 1/1.75 7/0.53 7/0.53 7/0.53 7/0.67 7/0.67 7/0.67 7/0.85 7/0.85 7/0.85 1/0.80* 1/0.80* 1/0.80* 1/0.80* 1/0.80* 1/0.80* Final diameter (mm) 7.1 8.0 8.3 8.0 8.5 9.4 9.4 10.0 11.0 8.4 8.9 9.8 9.9 10.3 11.8 11.5 12.2 13.5 10.0 11.3 12.5 14.5 15.0 17.0 Net weight (kg/km) 80 95 115 95 115 150 135 170 210 106 134 166 145 180 250 210 260 330 165 225 255 350 380 520 AC7 AC8 AC9 AC8 AC9 AC11 AC11 AC11 AC12 AC8 AC9 AC11 AC11 AC11 AC12 AC12 AC13 AC14 AC11 AC12 AC13 AC15 AC16 AC16 P clips type

Conductor
Plain annealed copper to BS6360 Solid (class 1) for 1 - 1,5 - 2,5 sqmm* Stranded (class 2) for 4 sqmm
* 1,5 - 2.5 sqmm are available with stranded conductor (class 2) (SR 114H - R)

4 x 1.0 2 x 1.5 3 x 1.5 4 x 1.5 2 x 2.5 3 x 2.5 4 x 2.5 2 x 1.5 3 x 1.5 4 x 1.5 2 x 2.5 3 x 2.5 4 x 2.5 2 x 4.0 3 x 4.0 4 x 4.0 7 x 1.0 7 x 1.5 12 x 1.0 12 x 1.5 19 x 1.0 19 x 1.5

Insulation
High performance silicone rubber EI 2 to BS 7655: section 1.1

Earth Conductor
Tinned annealed copper to BS6360 (drain wire for multicore cables)

Electrostatic Screen
Aluminium/polyester tape 125% coverage

Sheath
Thermoplastic zero halogen, low smoke, flame retardant, abrasion resistant Type LTS3 to BS 7655: section 6.1

* drain wire NOTE: cables up to 4 cores = Standard Products LPCB Approved.

FIRECEL SR114E are third party approved by LPCB which certify that FIRECEL SR114E cables have complied with the requirements of the following: BS 7629-1:2008 - 300/500 V fire resistant electric cables having low emission of smoke and corrosive gases when affected by fire - Multicore cables; Enhanced fire resistant cables as described in Clause 26.2e) of BS 5839-1:2002 - Fire detection and alarm systems for buildings. Code of practice for system design, installation, commissioning and maintenance; and achieved: Class PH120 when tested in accordance with BS EN 50200 - Method of test for resistance to fire of unprotected small cables for use in emergency circuits.

Electrical Characteristics
Voltage rating Temperature rating - for insulated conductors only Cross section (sqmm) Conductor resistance ( / km at 20 C) Insulation resistance (M x km at 20 C) Nominal Capacitance (pF / m) - core/core - core/screen 95 160 100 170 120 200 150 250 1 18.1 300 single or three phase circuit up to 300/500 V r.m.s. or up to 750 V d.c. circuit 40 +90 C max +200 C 1.5 12.1 300 2.5 7.41 300 4 4.61 300

Physical Characteristics
Nr. of conductors x section (sqmm) 2 x 1.0 3 x 1.0 4 x 1.0 2 x 1.5 3 x 1.5 4 x 1.5 2 x 2.5 3 x 2.5 4 x 2.5 2 x 1.5 3 x 1.5 4 x 1.5 2 x 2.5 3 x 2.5 4 x 2.5 2 x 4.0 3 x 4.0 4 x 4.0 7 x 1.0 7 x 1.5 12 x 1.0 12 x 1.5 19 x 1.0 19 x 1.5

Size of cond. (nr./mm) 1/1.13 1/1.13 1/1.13 1/1.38 1/1.38 1/1.38 1/1.75 1/1.75 1/1.75 7/0.53 7/0.53 7/0.53 7/0.67 7/0.67 7/0.67 7/0.85 7/0.85 7/0.85 1/1.13 1/1.38 1/1.13 1/1.38 1/1.13 1/1.38

Size of earth wire (nr./mm) 1/1.13 1/1.13 1/1.13 1/1.38 1/1.38 1/1.38 1/1.75 1/1.75 1/1.75 7/0.53 7/0.53 7/0.53 7/0.67 7/0.67 7/0.67 7/ 0.85 7/0.85 7/0.85 1/0.80* 1/0.80* 1/0.80* 1/0.80* 1/0.80* 1/0.80*

Final diameter (mm) 7.9 8.4 9.3 8.8 9.3 10.3 10.2 10.8 12.0 9.2 9.4 10.5 10.3 10.9 12.1 12.2 13.0 14.4 10.5 12.1 14.5 16.0 17.5 19.3

Net weight (kg/km) 85 105 125 105 130 165 150 190 240 110 135 170 155 190 250 220 280 350 175 230 300 380 470 590

P clips type AC8 AC9 AC11 AC11 AC11 AC11 AC11 AC11 AC12 AC9 AC11 AC11 AC11 AC11 AC12 AC12 AC13 AC15 AC11 AC12 AC14 AC16 AC18 AC19

Conductor
Plain annealed copper to BS6360 Solid (class 1) for 1 - 1,5 - 2,5 sqmm* Stranded (class 2) for 4 sqmm
* 1.5 - 2.5 sqmm are available with stranded conductor (class 2)

Insulation
Mica tape plus high performance silicone rubber EI 2 to BS 7655: section 1.1

Earth Conductor
Tinned annealed copper to BS6360 (drain wire for multicore cables)

Electrostatic Screen
Aluminium/polyester tape 125% coverage

Sheath
Thermoplastic zero halogen, low smoke, flame retardant, abrasion resistant Type LTS3 to BS 7655: section 6.1

* drain wire NOTE: cables up to 4 cores = Enhanced Products LPCB Approved.

Cavicel SpA 20096Pioltello (Milano) - Italy Via Caduti del Lavoro, 18/A ph. +39 - 02 - 921.605.21 fax +39 - 02 - 921.607.53 e-mail: cavicel@cavicel.com www.cavicel.com

CAVICEL firmly believes in the importance of the quality of its products and it undertakes itself to produce them using clean technologies for the respect and the protection of the environment.

Firecel is a Cavicel registered trademark. All information contained in this brochure is believed to be accurate. Specifications can change at any time, according to technical developments and market changes.