DIESEL GENERATOR SETS


Our 5 to 25 kW air and liquid-cooled diesel generator sets offer our traditional rugged designs, durability and reliability for applications ranging from nursing homes to wireless services, to prime power for small, remote, unattended sites. User-friendly operation and maintenance features include: Heavy-duty engines and high performance alternators Mechanical or (optional) electronic governing systems, and electronic voltage regulation Optional control systems for automatic, local, or remote start applications Optional weather-protective housings, coolant heaters, and other features to enhance performance and reliability in extreme ambient environments Complete set of accessory devices designed for use with the generator set to simplify installation and enhance reliability Cummins-powered diesel generator sets are available in sizes ranging from 35 to 2000 kW. Whether your application is for prime or continuous power, or if reliable standby power is critical to your business, Cummins provides standard features that have no equal. Heavy-duty Cummins engines are known for their stingy fuel efficiency, responsive transient performance, and rugged reliability. Each generator set includes a cooling system that is designed to provide guaranteed performance in high ambient temperatures, so you get all the power you pay for. High performance Cummins-manufactured alternators offer optimum performance in demanding applications, such as data centers and industrial plants.

Model

Power Output Rating Standby Prime Power (kW) (kW)

DNAA DNAB DNAC DNAD DKAC DNAE DKAE * DNAF * DKAF * DGBB * DGBC * DGCA * DGCB * DGDA * DGDB * DGDK DGEA * DGFA * DGFB * DGFC DFAB DFAC DQAD * DFBF DQAE * DQAF * DFCC DFCE DFEG * DFEH * DFEJ * DFEK * DFGB DFHA * DFHB * DFHC DFHD * DFJD DFLB DFLC DFMB DFLE * DQKB * DQKC * Available with EPA Nonroad Flex Program * Meets EPA Nonroad Emissions Requirements

60 Hz 50 Hz 5.0 4.0 7.5 6.0 7.5 6.0 11.5 9.0 15.0 12.5 16.0 12.5 20.0 16.0 20.0 16.7 25 20 35 28 40 32 50 40 60 50 80 65 100 85 125 100 125 110 150 140 175 150 200 175 230 200 250 220 250 220 275 250 275 250 300 275 350 310 400 N/A 350 318 400 330 450 400 500 450 600 550 750 620 800 700 900 800 1000 880 1000 880 1100 N/A 1250 1120 1500 1280 1500 1290 1750 1500 2000 1650

60 Hz 50 Hz 5.5 3.6 6.8 5.4 6.8 5.4 10.4 8.1 13.5 11.0 14.4 11.25 18.0 14.5 18.0 15.0 23 18 32 25 35 29 45 36 55 45 72 60 90 80 113 90 115 100 135 125 160 135 180 N/A 210 180 225 200 225 200 250 227 250 227 270 250 315 282 N/A N/A N/A N/A 360 320 410 365 455 400 545 500 680 560 720 640 818 725 900 800 900 800 900 N/A 1100 1000 1250 1070 1250 1100 1600 1350 1825 1500

POWERCOMMAND GENERATOR SETS CONTROL


Only Cummins generator sets are available with the industry-leading PowerCommand Control. This unique, field-proven control system offers features, performance, and reliability. A dazzling array of standard features includes not only integrated digital governing and voltage regulation, but also: both analog and digital metering; digital engine monitoring systems; smartstarting systems that actually regulate the fuel system based on engine temperature to improve stability, starting time and limit smoke; battery monitoring systems that test the genset batteries; AmpSentry true alternator protection; and more. PowerCommand controls offer the capability of integrated digital paralleling substituting less reliable, complex, and expensive paralleling equipment with simple, off the shelf solutions.

Most models UL 2200-listed. See your distributor for specific details.

SPARK-IGNITED GENERATOR SETS


Our spark-ignited generator sets, 6 to 150 kW, are available with natural gas, propane, and combined fuel systems. They can be used in a variety of lifesupport and related applications, including small health care facilities and retail businesses. Installation and hookup to the fuel source lines is both basic and convenient. As with our diesel generator sets, a complete selection of voltages, accessories, generator set, and control options are available for customizing to your specific needs. Major features include: Multiple control system options including those that are NFPA 110 compliant Natural Gas, Propane, or combination fuel systems Weather protective enclosures Some models available with optional low emissions closed loop fuel control system and 3-way catalyst which meets 1.5gm/hp-hr

QUIET SITE SOUND ATTENUATED GENERATOR SETS


Quiet Site provides two levels of sound attenuation to comply with stringent noise requirements. Sound attenuated housings can be factory installed or upfitted on existing generator sets by the local distributor as requirements emerge.
Model Power Output Rating Standby Fuel (kW) Prime Power (kW)

All features, options, and accessories of Cummins Power Generation diesel gensets up to 200 kW and spark-ignited gensets from 6 to 150 kW are available with Quiet Site enclosures. And Quiet Site can be configured for other stationary or trailerized applications. Quiet Site housings silence and protect the complete generator set, optimizing both genset performance and sound treatment to achieve low noise performance. Major features include: 15 to 200 kW, 60 Hz, 12.5 to 175 kW, 50Hz (Diesel) 20 to 150 kW, 60 Hz, 30.0 to 115 kW, 50 Hz (Spark-ignited) First stage: 65 to 80 dB(a) with full load at 7 meters Second stage: 61 to 72 dB(a) with full load at 7 meters Compact footprint, low profile design Easy access to all major generator, engine, and control components for servicing Upgrade kits
GNAA Natural Gas Propane (Vapor) GNAB Natural Gas Propane (Vapor) GNAC Natural Gas Propane (Vapor) GGDB Natural Gas Propane* GGFD Natural Gas Propane* GGFE Natural Gas Propane* GGHE Natural Gas Propane* GGHF Natural Gas Propane* GGHG Natural Gas Propane* GGHH Natural Gas Propane* GGKB Natural Gas Propane* GGKB Natural Gas

60Hz 50Hz 6.0 4.7 7.0 5.5 10.0 7.8 11.5 9.0 14.0 10.9 16.0 12.5 20 16 20 16 35 N/A 35 N/A 42 30 47 35 60 50 60 50 70 55 75 60 85 N/A 85 N/A 100 75 100 75 125 105 125 105 150 115

60Hz 50Hz 5.4 4.2 6.3 5.0 9.0 7.0 10.4 8.1 12.6 9.8 14.4 11.3 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 115 95 115 95 135 105

CARB (California Air Resources Board) Certification Available * Liquid or Vapor

LEAN BURN GAS GENERATOR SETS


Lean Burn Technology is Clean-Burning Technology
20

Cummins lean-burn gas gensets are designed to provide premier performance, fuel efficiency and low emissions for high-hour peaking and prime power applications. Using a lean mixture of fuel and air, combustion temperatures are significantly reduced, which minimizes the production of nitrogen oxides.

DETONATION
18
OPERATING WINDOW

BMEP (bar)

MISFIRE

16 14 12 10 8 0.6

The result is high power output with maximum thermal efficiency and minimal emissions. Already proven in over 200,000 hours of continuous duty operation around the world, these generators meet most federal, state, and local emissions requirements. Factory-integrated SCR after treatment options reduce NOx levels (as low as 0.15 grams/BHP-hr or less) to the most stringent air quality standards. Capable of running on variable quality gas from pipe-

0.8

1.0

1.2

1.4

1.6

1.8

2.0

Air Excess (lambda)


1 bar = 14.5 PSI NOx Efficiency

line natural gas to field gas or bio-gas with a methane number over 50, Cummins gas reciprocating engine technology and standard PowerCommand controls provide maximum operational flexibility for power generation applications.

Model

Power Output Ratings Continuous (kW)

334GFBA 315GFBA 1100GQMA 1250GQNA 1370GQMA 1540GQNA 1570GQMA 1750GWNB-50 1750GQNB-60

60 Hz 334 1100 1250 1750

50Hz 315 1370 1540 1570 1750

MICROTURBINES
Cummins 30 and 60 kW MicroTurbines are compact, ultra low emission, virtually maintenance-free power generators that allow either grid-connect operation, stand-alone, or automatic grid/ stand-alone switching options. The product features only one moving part: the integrated turbine/alternator shaft and patented foil air bearing; requires only one scheduled maintenance per 8000 hours, and delivers ultra low emissions (NOx < 9 ppm). The microturbine can operate on a wide range of hydrocarbonbased gaseous, liquid or low-BTU fuels. In addition, the machine is air cooled with no liquid coolants or lubricants to maintain or leak. The 30 and 60 kW models are built on the same no rust aluminum frame and enclosure with air inlet and outlet silencing that results in the quietest, standard production microturbine available. Applications favorable to Microturbines usually exhibit one or more of the following characteristics: High hour availability requirements over 4000 hours per year Low cost fuels Poor quality fuel energy content as low as 350 BTU or dirty (up to 7% H2S) Ultra low emissions requirements < 0.15 g/hp-hr Combined Heat and Power (CHP) heating or absorption chilling, especially in areas where government incentives are available for CHP High reliability and power quality for critical electrical loads Remote locations where scheduled maintenance events are costly Quiet operation
DC-Powered Generator Sets
Reliable Cummins DCathlon generator sets are designed to keep remote telecom and wireless sites running. They enhance system reliability and reduce your battery plant size, lowering battery costs, and cabinet space requirements while providing long-term backup power. DCathlon generator sets improve reliability by connecting directly to the DC bus, bypassing the rectifier and eliminating the need for a transfer switch. Without using revenue-generating phone lines, you can continuously monitor your genset and battery plant, thus simplifying maintenance. All generator sets are tested to meet Telcordia requirements, such as: GR-63, GR-487, GR-1089, as well as UL2200 listing.

Major features include:


Standard sound attenuated, aluminum, locking enclosure Nominal 24 or 48 volt outputs Variable speed natural gas or propane engine matches RPM to load and voltage requirements Permanent magnet alternator Direct connection to DC bus reduces battery requirements and extends battery life Microprocessor control monitors both AC and battery voltage, controls genset operation, and protects the genset and loads Internal exhaust system and muffler

Model Model Power Output Rating

Power Output Rating

GTAA GTAB

30kW 60kW

GCAA GCAB GCAC

3.0kW 4.5kW 5.5kW

DIGITAL PARALLELING EQUIPMENT


Paralleling is an integrated function of our microprocessorbased genset control, PowerCommand. In addition to all monitoring, protection, governing, and voltage regulation functions, PowerCommand provides all paralleling control functions, including synchronizing, load sharing, and paralleling protection. The PowerCommand control even provides utility (mains) paralleling functions such as import/export control and var/power factor control. Digital design and integration not only saves space, but can also improve system reliability and performance.
Digital MasterControl

The PowerCommand Model 200 and 300 Digital MasterControl, with its unique industrial PC-based touchscreen operator interface and software-based design, is a perfect complement to the PowerCommand generator set control for applications that demand maximum ease of use and extensive control capabilities. Major features include: Internet/Intranet capable for remote monitoring and alarm dialout. Broad range of master control products to suit any application Isolated and infinite bus (utility mains paralleling) designs Easily integrates into other building control systems Suitable for applications up to 15,000 VAC, ANSIC 37.2, UL-1670 listed Power sections available using either stationary or drawout breakers, in UL-891, UL-1558 CSA or IEC type medium voltage designs, UL-1670 listed Front only or front/rear access switchboard designs Not every application demands the premium feature set of our 200/300 masters. For those applications, our model 150 control provides needed features such as: True RMS main bus metering Load add and shed controls Load demand Easy to use operator interface
Digital Paralleling Load Transfer Equipment

Specifically designed for closed transition transfer, our digital paralleling load transfer equipment, rated from 800 to 3000
Model Descriptions

amps, transfers power between a generator set and utility service without interrupting power to critical loads. Service entrance rating, ground fault protection, and utility protective relaying are available. UL-891, UL-1008 listed.

PLTO PLTH PLTS PLTE

Open Transition Transfer with Programmed Transition Mode 100 millisecond Closed Transition Transfer Soft Loading Closed Transition Transfer Extended Paralleling/Peak Shaving

TRANSFER SWITCH EQUIPMENT


Although we are best known for our gensets, Cummins Power Generation has long been a leading provider of transfer switches with thousands of installations worldwide. After decades of design and manufacturing experience, we understand the importance of pre-integration of the entire on-site system, including transfer switches, switchgear, and gensets.
OTPC Automatic Transfer Switches LTIII Automatic Transfer Switches
The LTIII transfer switch line combines reliability and flexibility in a small, economical package for transfer of power between the utility service and a generator set. The LTIII is ideal for low-power applications where basic switching functions and control options are required.

OTPC switches incorporate digital microprocessor-based controls for utilityto-utility, utility-to-genset, or genset-to-genset applications. They employ many standard and optional features, including a front panel digital display, optional bar graph meters, programmed transition, and optional simultaneously switched neutral. Major features include: UL-listed withstand and closing ratings up to 200kA Voltage surge protection High visibility LED-indicating lamps provide at-a-glance source and ATS status for quick summary of system conditions Convenient front panel digital display provides easy access to review power and load conditions, make adjustments, review events, and check network status Designed to be configurable through the operator panel or InPower , a PC-based service tool
BTPC Automatic Transfer Switches with Bypass Isolation

Major features include:


UL-listed withstand and closing ratings up to 100kA Single control board with all standard features for improved reliability and serviceability LED status indictors for source available and switch position, normal or emergency Voltage surge protection limits damage to the control from inadvertent voltage spikes

The BTPC Bypass Isolation transfer switch combines an OTPC transfer switch, a two-source manual bypass switch, a closed door drawout isolation mechanism, and microprocessor-based controls. The switch allows maintenance, service, and testing of the ATS without disrupting power to critical loads. For environments with critical power requirements, such as healthcare and data center facilities, the BTPC will combine safe reliable service with simple operation. Major features include: Front panel digital display; optional bar graph meters UL-listed withstand and closing ratings up to 200kA Non-load break bypass maintains service to critical loads when the ATS is drawn out of service External manual operation capability for the ATS Dead source interlocks prevent the operator from connecting loads to a failed utility or generator source Full mechanical interlock system prevents accidental interconnection of the power sources.
LTIII Transfer Switch Ratings OTPC BTPC

(3Pole) 30 60 100 150 200 260 N/A N/A N/A N/A N/A N/A N/A N/A N/A

(3Pole) 40 70 125 150 225 260 300 400 600 800 1000 1200 1600 2000 3000

(4Pole) N/A N/A N/A 150 225 260 300 400 600 800 1000 1200 1600 2000 3000

(3Pole) N/A N/A N/A 150 225 260 300 400 600 800 1000 1200 1600 2000 3000

(4Pole) N/A N/A N/A 150 225 260 300 400 600 800 1000 1200 1600 2000 3000

All transfer switches are rated for operation at various voltages from 120-600 VAC, 50 or 60 Hz.

THE POWER SUITE


The Power Suite, on CD-ROM, is available from your local Cummins distributor.
PowerCommand Network
PowerCommand Network is an innovative, Windows-based, distributed system for operating and maintaining emergency standby or prime power systems. Regardless of the equipment manufacturer, this microprocessor-based network system allows: local or remote monitoring and control, real-time data collection, retention, and report generation on generator sets, transfer switches, paralleling controls, switchgear, and other related power generation and distribution equipment. We also have standard interfaces with all leading building management systems and automation packages that allow you to communicate effectively with your energy management operations.

This tool contains easy-to-use generator set sizing software, product specification and data sheets, key drawings in both viewable image and CAD formats along with other application technical information. This comprehensive set of product information and software tools is designed to assist the user in selecting appropriate power generation products and identifying facility design and installation requirements. The Power Suite includes:
GenSize

A comprehensive, easy-to-use generator set sizing software that allows the user to quickly determine the optimum Cummins generator set required for power generation applications. Simply enter project requirements and electrical loads and GenSize calculates generator loading, required generator performance, and provides product recommendations.
Library

This is the electronic version of our Power Systems Manual containing all product specification and data sheets plus much more. The Library also contains outline and schematic drawings, even in CAD format. After using GenSize to determine which Cummins generator set best meets project requirements, the Library can be used to acquire documentation containing information needed for facility design. Also included are application manuals and technical papers on a variety of power generation topics.
GenCalc

Contains software tools to assist in generator set installation design including alternator decrement curves for short circuit studies and tools to aid in sizing fuel and exhaust system components.
Minimum personal computer requirements:
Hardware: 64 MB Ram and 70 MB free Hard Drive space Software: Microsoft Windows 95, 98, NT, or 2000 Microsoft Internet Explorer 5.01, Microsoft Word and Adobe Acrobat Reader 4.0

GenSpec

Includes a series of product Sample Specifications in Word format that can be used as a source for power generation project specifications.

The Power of One

Cummins Power Generation and PowerCommand are registered trademarks of Cummins Power Generation, AmpSentry and The Power of One are trademarks of Cummins Power Generation Corporation. Cummins is a registered trademark of Cummins Inc. All other trademarks are owned by their respective companies. Backfeed to a utility system can cause electrocution and/or property damage. Do not connect to any buildings electrical system except through an approved device or after building main switch is opened. Specifications are subject to change without notice. 2002 Cummins Power Generation Printed in the U.S.A. Bulletin F-1186 Rev 01/02