Visual and Ultrasonic Inspection of Cranes
by Alex Bagarry III*

The importance of regular NDT inspections in preventing catastrophic failures is well recognized. This month's article describes the application of ultrasonic technique for inspecting cranes. The capability of ultrasonics in detecting, characterizing, and determining the probable cause of cracks in structural studs used in these cranes is discussed. G.P. Singh Associate Technical Editor

Figures 1-3

Problem

Our company was recently contracted to perform


ultrasonic and visual inspections on a number of the 1.2 metric ton (40 ton) capacity "hammerhead" cranes used in Wilmington, California to load and unload the container ships plying the waters of the Pacific Rim. These cranes had been in service for 15 to 25 years and were periodically inspected for degradation of their structural

http://www.asnt.org/publications/materialseval/solution/jul98solution/jul98sol.htm (1 of 3)11/02/2006 20.01.53

The American Society for Nondestructive Testing

elements. The ultrasonic portion of the examinations included contact angle beam scanning of the structural welds joining various tubular and "H" shapes of the boom assembly, and also straight beam examination of the structural studs that held the A-frame supports to the boom platform and machine house. There were a total of 20 studs inspected on each of six cranes. The dimensions of each stud were 50 mm (2 in.) diameter and 246 mm (9.7 in.) length. Ultrasonic examination showed a reflection on several studs from 3.81 mm (1.5 in.) to 7.62 mm (3 in.) below the scanning surface and in the threaded area inside of each top nut (see Figure 1).

The graphic
representation of the data helped us identify the cause of the cracking.

Additional scanning and evaluation allowed us to identify the shape of the crack through the partial cylinder of the threaded stud end. Comparing the data from stud to the next in the series was enlightening. We plotted the position of each crack on a single graphic report. The graphic representation of the data helped us identify the cause of the cracking (see Figure 2). The alignment of the ultrasonically plotted cracked areas indicated that the probable cause of these discontinuities was a side-impact load on the boom end occurring while in the boom-down position. The side leverage obtained by a large container ship impacting the side of the boom could more than
http://www.asnt.org/publications/materialseval/solution/jul98solution/jul98sol.htm (2 of 3)11/02/2006 20.01.53

The American Society for Nondestructive Testing

exceed the shear resistance of these stud assemblies (see Figure 3). In summary, the value of regularly scheduled NDT inspections should be recognized for its true worth. The contribution to public safety - and perhaps lives saved by this inspection far outweighs the relatively insignificant costs associated with these inspections. This early warning system allowed the maintenance crew to schedule repairs in a timely manner, thus reducing the local government's potential liability by the possible prevention of a catastrophic failure.

* ABC Inspection & Engineering Support Services, 4201 W. 5th St., No. 109, Santa Ana, CA 92703; (714) 2652154.
Copyright 1998 by the American Society for Nondestructive Testing, Inc. All rights reserved.

[ Materials Evaluation ]

Copyright 2006 by the American Society for Nondestructive Testing, Inc. ASNT is not responsible for the authenticity or accuracy of information herein. Published opinions and statements do not necessarily reflect the opinion of ASNT. Products or services that are advertised or mentioned do not carry the endorsement or recommendation of ASNT. IRRSP, NDT Handbook, The NDT Technician and www.asnt.org are trademarks of the American Society for Nondestructive Testing, Inc. ACCP, ASNT, Level III Study Guide, Materials Evaluation, Nondestructive Testing Handbook, Research in Nondestructive Evaluation and RNDE are registered trademarks of the American Society for Nondestructive Testing, Inc. ASNT exists to create a safer world by promoting the profession and technologies of nondestructive testing.

http://www.asnt.org/publications/materialseval/solution/jul98solution/jul98sol.htm (3 of 3)11/02/2006 20.01.53

The American Society for Nondestructive Testing

Home Marketplace Certification Publications Membership Meetings and Events Local Sections Links What's New Learning Awards and Honors

Members Only | Contact Us | Shop ASNT | Search

NDT Solution
Visual and Ultrasonic Inspection of Cranes Figures 1-3

Figure 1 - Schematic of the crane subsection and stud cross section. [ Back to July '98 NDT Solution ]

http://www.asnt.org/publications/materialseval/solution/jul98solution/jul98solfig1-3.htm (1 of 4)11/02/2006 20.02.19

The American Society for Nondestructive Testing

Figure 2 - Graphic representation showing stud locations; darkened areas show where shearing occurred. This graphic helped identify cause of the shearing. [ Back to July '98 NDT Solution ]

http://www.asnt.org/publications/materialseval/solution/jul98solution/jul98solfig1-3.htm (2 of 4)11/02/2006 20.02.19

The American Society for Nondestructive Testing

Figure 3 - This drawing shows the crane boom and base in relation to the source of the side impact loading. [ Back to July '98 NDT Solution ]

Copyright 1998 by the American Society for Nondestructive Testing, Inc. All rights reserved.

[ Materials Evaluation ]

Copyright 2006 by the American Society for Nondestructive Testing, Inc. ASNT is not responsible for the authenticity or accuracy of information herein. Published opinions and statements do not necessarily reflect the opinion of ASNT. Products or services that are advertised or mentioned do not carry the endorsement or recommendation of ASNT. IRRSP, NDT Handbook, The NDT Technician and www.asnt.org are trademarks of the American Society for Nondestructive Testing, Inc. ACCP, ASNT, Level III Study Guide, Materials Evaluation, Nondestructive Testing Handbook, Research in Nondestructive Evaluation and RNDE are registered trademarks of the American Society for Nondestructive Testing, Inc. ASNT exists to create a safer world by promoting the profession and technologies of
http://www.asnt.org/publications/materialseval/solution/jul98solution/jul98solfig1-3.htm (3 of 4)11/02/2006 20.02.19

The American Society for Nondestructive Testing

nondestructive testing.

http://www.asnt.org/publications/materialseval/solution/jul98solution/jul98solfig1-3.htm (4 of 4)11/02/2006 20.02.19