DBS3800 Hardware Description

4 Introduction to the BBU3806C

4
About This Chapter
l l l l

Introduction to the BBU3806C

The BBU3806C is an outdoor baseband unit that processes baseband signals. The BBU3806C has the following functions: Providing ports for data communication between the BBU3806C and the RNC Providing OM channels between the BBU3806C and the LMT or the M2000 to operate and maintain the BBU3806C Providing SAAL paths for the signaling processing between the BBU3806C and the RNC Providing the CPRI interface for communication between the BBU3806C and the RRU3801C Processing uplink and downlink baseband signals Managing the entire distributed NodeB system in terms of OM and signaling processing Providing the system clock

l l l

4.1 Appearance of the BBU3806C The BBU3806C is the outdoor model of the BBU3806. 4.2 Panel of the BBU3806C The BBU3806C has panels at the module bottom, on the cabling cavity, and on the maintenance cavity. 4.3 LEDs on the BBU3806C The LEDs are on the panel of the BBU3806C maintenance cavity, which indicate the running status of the BBU3806C. 4.4 Ports on the BBU3806C The ports on the BBU3806C consist of grounding ports, power supply ports, transmission ports, alarm ports, and other ports. 4.5 DIP Switch on the BBU3806C The BBU3806C has only one DIP switch. 4.6 Engineering Specifications for the BBU3806C This describes the engineering specifications for the BBU3806C.
Issue 03 (2008-01-15) Huawei Technologies Proprietary 4-1

4 Introduction to the BBU3806C

DBS3800 Hardware Description

4.1 Appearance of the BBU3806C


The BBU3806C is the outdoor model of the BBU3806. Figure 4-1 shows the BBU3806C. On the left is a front view of the BBU3806C without the housing, in the middle is a side view of the BBU3806C without the housing, and on the right is a front view of the BBU3806C housing. Figure 4-1 BBU3806C

4.2 Panel of the BBU3806C


The BBU3806C has panels at the module bottom, on the cabling cavity, and on the maintenance cavity. Figure 4-2 shows the panels of the BBU3806C.

4-2

Huawei Technologies Proprietary

Issue 03 (2008-01-15)

DBS3800 Hardware Description

4 Introduction to the BBU3806C

Figure 4-2 Panels of the BBU3806C

Table 4-1 describes the ports, LEDs, and DIP switch on the panel of the BBU3806C. Table 4-1 Ports, LEDs, and DIP switch on the panels of the BBU3806C Item Ports at the bottom Label 8*E1/T1 2*FE RS485&EXT_ALM PWR E1 GND GPS Port for external alarms Socket for power supply Port for E1 grounding connection Port for GPS signal input Description Ports for Iub transmission

Issue 03 (2008-01-15)

Huawei Technologies Proprietary

4-3

4 Introduction to the BBU3806C

DBS3800 Hardware Description

Item

Label OPT

Description Reserved Ports for interconnection between the BBU3806C and the RRU3801C Reserved Port for commissioning Port for testing Port for clock signal output Power switch of the BBU3806C Button used to reset the BBU3806C For details, refer to 4.3 LEDs on the BBU3806C.

Ports on the cabling cavity

CPRI0 to CPRI2 EIa

Ports on the maintenance cavity

ETH_RS323 8K/TTI 10M ON/OFF RST

LEDs

RUN ALM ACT LIU0 to LIU7 CPRI0 to CPRI2

DIP switch

LOCAT_ID E1/T1

For details, refer to 4.5 DIP Switch on the BBU3806C.

4.3 LEDs on the BBU3806C


The LEDs are on the panel of the BBU3806C maintenance cavity, which indicate the running status of the BBU3806C. For the positions of the LEDs on the BBU3806C, refer to 4.2 Panel of the BBU3806C. Table 4-2 describes the LEDs and their states. Table 4-2 LEDs on the BBU3806C Label RUN Color Green State ON OFF 1 s ON, 1 s OFF Description The BBU3806C is checking the version, or the module is faulty. The BBU3806C has no power input, or the module is faulty. The BBU3806C is running as configured.

4-4

Huawei Technologies Proprietary

Issue 03 (2008-01-15)

DBS3800 Hardware Description

4 Introduction to the BBU3806C

Label

Color

State 0.25 s ON, 0.25 s OFF

Description The software is being loaded to the BBU3806C, or the BBU3806C is not configured. The BBU3806C is reporting alarms (not including VSWR-related alarms). The BBU3806C is operational. The BBU3806C is active. The BBU3806C is not in use. Local alarms related to the E1/T1 are reported. Remote alarms related to the E1/T1 are reported. The link is not in use, or the alarm is cleared. Local alarms related to LOS are reported. Remote alarms related to LOS are reported. The ports are normal or not in use.

ALM

Red

ON OFF

ACT

Green

ON OFF

LIU0 to LIU7

Yellow

ON 0.25 s ON, 0.25 s OFF OFF

CPRI0 to CPRI2

Yellow

ON 0.125 s ON, 0.125 s OFF OFF

4.4 Ports on the BBU3806C


The ports on the BBU3806C consist of grounding ports, power supply ports, transmission ports, alarm ports, and other ports.

Grounding Ports
The BBU3806C has two grounding bolts at the bottom.

Power Supply Ports


Table 4-3 Power supply ports on the BBU3806C Application Power supply ports Port +220 V AC or 48 V DC power Quanti ty 1 Connector Type 9-pin, round, and waterproof

Issue 03 (2008-01-15)

Huawei Technologies Proprietary

4-5

4 Introduction to the BBU3806C

DBS3800 Hardware Description

Transmission Ports
Table 4-4 Transmission ports on the BBU3806C Application Iub interface Port E1 T1 Fast Ethernet Quantity 1 (8 E1s) 1 (8 T1s) 2 Data Rate 2 Mbit/s 1.5 Mbit/s 100 Mbit/s Full-duplex Optical ports between the RRU3801Cs CPRI 3 1.25 Gbit/s Connector Type 32-pin, round, and waterproof 32-pin, round, and waterproof 8-pin, round, and waterproof ESFP socket

Alarms Ports
Table 4-5 Alarm ports on the BBU3806C Application Alarms ports Port RS485 Four dry contacts Quantity 1 1 Connector Type DB15

Table 4-6 Specifications for the alarm ports on the BBU3806C Specification Closed resistance Open resistance Parameter < 0.2 k ohm < 51 k ohm

Other Ports
Table 4-7 Other ports on the BBU3806C Application E1 grounding selection GPS signal input
4-6

Port Grounding connections for eight coaxial E1s

Quanti ty 1 1

Connector Type 19-pin, round, and waterproof N-type


Issue 03 (2008-01-15)

Huawei Technologies Proprietary

DBS3800 Hardware Description

4 Introduction to the BBU3806C

Application Clock signal input/ output Testing Commissioning

Port 10 MHz clock signal output 8 kHz TTI Testing Serial or Ethernet

Quanti ty 1 1 1

Connector Type SMB male SMB male RJ45

4.5 DIP Switch on the BBU3806C


The BBU3806C has only one DIP switch. Figure 4-3 shows the DIP switch on the BBU3806C. Figure 4-3 DIP switch on the BBU3806C

Bits 1 and 2 are reserved, and bits 3 and 4 are used to set the E1/T1 mode and line impedance. Table 4-8 describes the settings of bits 3 and 4 on the DIP switch. Table 4-8 Settings of bits 3 and 4 on the DIP switch Bit 3 OFF OFF ON ON Bit 4 OFF ON OFF ON Description 120-ohm E1 100-ohm T1 Reserved 75-ohm E1 by default

Issue 03 (2008-01-15)

Huawei Technologies Proprietary

4-7

4 Introduction to the BBU3806C

DBS3800 Hardware Description

4.6 Engineering Specifications for the BBU3806C


This describes the engineering specifications for the BBU3806C.

Physical Dimensions
l

The dimensions of the BBU3806C (without the bracket and housing) are 355 mm x 135 mm x 480 mm (W x D x H). The dimensions of the BBU3806C (with the bracket and housing) are 380 mm x 200 mm x 610 mm (W x D x H).

Weight
The weight of the BBU3806C is 15 kg at most.

Power Input
Table 4-9 Power input to the BBU3806C Rated Voltage 48 V DC 220 V AC Operating Voltage Range 40 V DC to 60 V DC 150 V AC to 300 V AC Remarks 47 Hz to 63 Hz

Power Consumption
l

If 48 V DC power is used, the maximum power consumption of the BBU3806C is 100 W. If 220 V AC power is used, the maximum power consumption of the BBU3806C is 120 W.