ReadMe

This document contains important information about the SoMove Lite software. Please read the complete document before you start the installation and operation of the product.

Schneider Electric assumes no responsibility for any errors that may appear in this document. If you have any suggestions for improvements or amendments or have found errors in this publication, please notify us. No part of this document may be reproduced in any form or by any means, electronic or mechanical, including photocopying, without express written permission of Schneider Electric. All pertinent state, regional, and local safety regulations must be observed when installing and using this product. For reasons of safety and to help ensure compliance with documented system data, only the manufacturer should perform repairs to components. When devices are used for applications with technical safety requirements, the relevant instructions must be followed. Failure to use Schneider Electric software or approved software with our hardware products may result in injury, harm, or improper operating results. Failure to observe this information can result in injury or equipment damage. 2012 Schneider Electric. All rights reserved.

1 SoMove Lite V1.5.1.0


SoMove is user-friendly setup software for PCs, for setting up of Schneider Electric motor control devices. SoMove software incorporates various functions for the device setup phases, such as Configuration preparation, Start-up and Maintenance.

1.1 Registration The Product must be registered with in 4 days of first use, if not the application will stop working after this period. You must register to continue to use the product.

1.2 Products supported Altivar 12, Altivar 312, Altivar 32, Altivar 71, Altivar 61, AlitvarLift, Altistart 22, Altistart 48, Lexium 32A, Lexium 32M, Lexium 32C, Tesys U and Tesys T

2 System Requirements
2.1 Supported Operating Systems This software can be installed on the following operating systems: > Microsoft Windows XP Professional SP3 32 Bit > Microsoft Windows Vista Business Edition 32Bit SP1 > Microsoft Windows 7 32 bit > Microsoft Windows 7/Vista 64 bit

2.2

Minimum Hardware Configuration

EQUIPMENT
Processor RAM Free Hard Disk Space Display Peripherals Peripherals

MINIMUM
Processor: Pentium III @1.2 GHz or higher 1 GB 1 GB of free disk space Must be available Resolution: 1024 x 768 pixels with 32 bit colors DPI: 96 A mouse or compatible pointing device USB interface

2.3

Recommended Hardware Configuration RECOMMENDED Processor: Pentium IV @1.3 GHz or higher 2 GB 2 GB Resolution: 1280 x 1024 pixels with 32 bit colors DPI: 96

EQUIPMENT Processor RAM Free Hard Disk Space Display

2.4 Pre-requisites .NET Framework 3.5 SP1 must be installed, before installing SoMove. This is downloadable from the Microsoft website at below link http://download.microsoft.com/download/2/0/e/20e90413-712f-438c-988efdaa79a8ac3d/dotnetfx35.exe Adobe version 8.0 and above recommended for the proper functioning of Online help

3 Installation
3.1 Administrator Privileges In order to install SoMove Lite software, you must have administrative privileges to install and uninstall programs. Note: Admin privileges are not required to run SoMove Lite once installed. 3.2 Re-installing or Uninstalling You can re-run the installer from the Add/Remove Programs Control Panel. If you have already installed SoMove Lite, the installer gives you options to Modify, Repair or Remove SoMove Lite. Note: To Modify or Repair SoMove installer should be available.

4 Restrictions
1. Limited print features (only parameters list is printable) 2. In Communication -> Edit connection -> Advanced, the scan modes Range and All for MB TCP communication will always connect the first device in the scan range. 3. SoMove will not run properly if Chinese fonts are not available in the system. You need to relaunch the application and the language will be English by default. You may change the language after this relaunch. 4. Com port setting are disabled sometimes (Random behavior)

5. SoMove crashes with COM port configured to COM3 in some laptops.

5 AltivarDtmLibrary
5.1 Overview
The AltivarDtmLibrary is a software component which represents a package of several DTMs. The AltivarDtmLibrary Installer is the child installer of SoMove Lite which will launch the different DTM installers that it referenced. The following schema represents the Tree of installers of the AltivarDtmLibrary. Altivar DTM Library Installer > ATV12 DTM Installer > ATV31 DTM Installer > ATV32 DTM Installer > ATV71 DTM Installer > ATV61 DTM Installer > ATVLift DTM Installer

5.2 AltivarDtmLibrary referenced DTM


Software Component Name
AltivarDtmLibrary ATV12 ATV31/312 ATV32 ATV71 ATV61 ATVLift

Version
V 5.0.6 V 1.4.11.0 V 1.5.1.0 V 1.4.13.0 V 1.5.1.0 V 1.5.1.0 V 1.5.1.0

5.3 New or improved in this version

> ATV71S383 version support >Configuration file recovery from Powesuite2 to SoMove > Drive topology Reference filtering for ATV312, ATV61, ATVLift > Oscilloscope (slow & fast) for ATVLift > Modified parameter view for ATV312, ATV61 and ATVLift > Alarm management for ATV61 and ATVLift > Operate panel view for ATV61 and ATVLift > Modbus multidrop/multidrop connection support > Firmware compatibility for ATV61, ATV71 and ATVLift > Configuration comparison (offline and online) for ATV312, ATV61, ATV71 & ATVLift > Download and compare of configuration for ATV312, ATV61, ATV71 & ATVLift > Contextual help available for ATV61, ATV71 & ATVLift > Improved Parameter switching feature for ATV71 > Diagnostics feature for ATV61 & ATV71 > Wizard feature for Pump application in ATV61 > Command panel feature included for ATV61

5.4 Information
5.1.1 Function: Connection, Load from device, Store to device actions are prohibited when ARE<>No in the connected device. This parameter is reserved to transfer ATV31 configurations with a loader or keypad. > DTMs: ATV31-312

5.5 Restrictions
5.1.2 5.1.3 5.1.4 5.1.5

No contextual help
> DTMs: ATV12, ATV31-312, ATV71, ATV32,ATV61 Device conversion (firmware compatibility) is not available with this version > DTMs: ATV71 Multi-Loader Import/Export function is not available. > DTMs: ATV61 FDR function does not SAVE with SoMove (with a PLC configured) > DTMs: ATV61

5.6 Known Issues


5.1.6 5.1.7 Several Help button exists in dialog boxes but have no action > DTMs: ATV12, ATV31-312, ATV71, ATV32,ATV61 Store to device is not permitted when the PLC program is running in the connected device, a popup error indicates Store to device is not possible. > DTMs: ATV32 Command panel sometimes cannot be made inactive when the ADC parameter in automatic DC injection is changed to continuous and executed a Run and stop. > DTMs: ATV32 Command Panel: Drive status is not updated even after resetting the EPF1 (External fault on Li3). Updates only on restarting the application

5.1.8

5.1.9

> DTMs: ATV32 5.1.10 Random exception thrown when assigning multi configuration through drive. > DTMs: ATV32 5.1.11 MyMenu sometimes does not get updated in the drive after setting it through the application. > DTMs: ATV32 5.1.12 After the connection lost, drive still shows online for long time and command panel also is in active state > DTMs: ATV32 5.1.13 Export to PDF file: Some parameters are missing in the pdf file. e.g.:-EN 19 to EN 35, OIR and TAFI. > DTMs: ATV32 5.1.14 ILF error is not displayed in the Error history. > DTMs: ATV312 5.1.15 Store to device is not updating LLS & LTS value in drive. > DTMs: ATVLift 5.1.16 Parameter set switching does not work for frequency threshold if changed via command panel. > DTMs: ATV71 More details on restrictions is available in Altivar ReadMe file

5.7 Troubleshoot
1. Load from Device - If a load from device action is interrupted by a device power OFF, then the subsequent load from device actions will fail.

Resolution:
* Power ON the device and try Load from device again, or if problem persists still then * Restart SoMove and try Load from device again

2. Functional Block - In ATVLogic configuration dialog box, an error message warns Date is integer. Resolution: * The date must be entered in the required format: 8 digits: MMDDYYYY 3. Functional Block - If you want copy / paste a whole program from the PRE to the AUX for example, we have the following behavior: > Only blocks are pasted (no Inputs/outputs and no links will be pasted). > The past operation will not paste all blocks copied from the PRE section. It depends on the position of the last click in the window. > Create link on 'paste blocks' is not always possible. In this case, it is necessary to delete blocks and create new one. 4. Mono/Multi Configuration: When Personalization is done in mono configuration, changes are shown in customized parameters but the same are not reflecting in the actual configuration. > For this to work user has to Power Off and On the drive after parameter personalization is done via SoMove, due to drive behavior.

6 AltistartDtmLibrary 6.1 Overview


The AltistartDtmLibrary is a software component which represents a package of several DTMs. The AltistartDtmLibrary Installer is the child installer of SoMove Lite which will launch the different DTM installers that it referenced. The following schema represents the Tree of installers of the AltistartDtmLibrary. Altistart DTM Library Installer > ATS22 DTM Installer > ATS48 DTM Installer

6.2 AltistartDtmLibrary referenced DTM


Software Component Name
AltistartDtmLibrary ATS22 ATS48

Version
V4.0.2 V 1.4.5.0 V 1.5.0.1

6.2.1 New or improved in this version


> ATS48 command panel > ATS48 Operate panel

6.3 Restrictions
6.3.1 No contextual help.

> DTMs: ATS22, ATS48


6.3.2 Label translations not available in this version

> DTMs: ATS48


6.3.3 Safety messages not available in this version

> DTMs: ATS48

6.4 Known Issues


6.4.1 Several Help button exists in dialog boxes but have no action

> DTMs: ATS22, ATS48


6.4.2 In the Fault Tab , LFT parameter when it is having INF fault , save the project and open back

, the long label remains as INF instead of Internal Detected Fault and when FCS is performed when LFT is INF on a opened project , Long Label and Value becomes Empty . > DTMs: ATS22 6.4.3 If the fault is INF, the value column is updated as Internal- in the fields other than LFT also. > DTMs: ATS22, ATS48

6.5 Troubleshoot
1. Load from Device - If a load from device action is interrupted by a device power OFF, then the subsequent load from device actions will fail.

Resolution:
* Power ON the device and try Load from device again, or if problem persists still then * Restart SoMove and try Load from device again

7 ModbusDtmLibrary
This document gives recommendations and provides additional information for installing and running the

Communication DTM for Modbus Serial Communication DTM for Modbus TCP
Software Component Name MdobusDtmLibrary MB Serial Communication DTM MB TCP Communication DTM Version V 2.0.8 V 2.0.24 V 2.0.19

Note: During the installation of the Modbus Communication Library also the Schneider PC Driver for Modbus Serial Line will be installed on the system.

7.1 Program Group

The installation will not add any folder in the Programs group oft the Start menu because the Modbus Communication DTM Library can only be used inside an FDT Frame Application.

7.2 Directories

By default, Modbus Communication DTM Library Configuration Software will be installed in the directory. -<CommonProgramFiles> -Schneider Electric Shared - Modbus Communication DTM Library - Modbus Serial Line CommDTM - Modbus TCP CommDTM

where <CommonProgramFiles> depends on the settings of your machine. In a default system installation, this directory is usually "C:\Program Files\Common Files\ ". The default setting can be modified at the time of installation to meet your specific requirements.

8 LexiumDtmLibrary 8.1 Overview


The LexiumDtmLibrary is a software component which represents a package of several DTMs. The LexiumDtmLibrary Installer is the child installer of SoMove Lite which will launch the different DTMs installers that it referenced. The following schema represents the Tree of installers of the LexiumDtmLibrary. Lexium DTM Library Installer > LXM32A DTM Installer > LXM32C DTM Installer > LXM32M DTM Installer

8.2. LexiumDtmLibrary referenced DTM


Software Component Name
LexiumDtmLibrary LXM32A LXM32C LXM32M

Version
V 1.5.04 V 1.5.04 V 1.5.04 V 1.5.04

8.3 New or improved in this version


> Contextual help on parameter > New BMH190 motors > Improved download of motion sequence data > Show modified values in motion sequence editor > Full list of homing methods supported > Show error class in error history

8.4. Information
8.4.1 Store to device action is prohibed when PowerStage is enabled

> DTMs: LXM32A, LXM32C, LXM32M


8.4.1 Scaling Sketch not available for following drive versions as the rescaling function is not

supported by the drive > DTMs: LXM32A <V1.6, LXM32C <V1.6, LXM32M <V1.4

8.5. Restrictions
4.1
Supported Languages DE, EN, FR, IT, ES

> DTMs: LXM32M 4.2 Supported Languages IO Module English & German only > DTMs: LXM32M Safety Validation Assistant not implemented > DTMs: LXM32M Scaling Wizard with basic functions. > DTMs: LXM32M MultiLoader Import/Export is not supported. > DTMs: LXM32A, LXM32M, LXM32C.

4.3 4.4 4.5

8.6. Known Issues


5.1 5.2 5.3 5.4 5.5 Several Help button exists in dialog boxes but have no action > DTMs: LXM32A, LXM32C, LXM32M Oscilloscope: no auto scale after acquisition with Keep Trace function > DTMs: LXM32A, LXM32C, LXM32M Oscilloscope: LXM32M: Selecting an empty Slot in the Channel select dialog may lead to a crash> DTMs: LXM32M Sporadic connection Lost may occur due to bad timing behavior of USB to RS485 dongles > DTMs: LXM32A, LXM32C, LXM32M eSM config: Sometimes the button to change to Grid view disappears. Save and reopen the project to solve this issue. > DTMs: LXM32M

9 TesysDtmLibrary 9.1 Overview


The TeSysDTMLibrary is a software component which represents a package of several DTMs dedicated to SoMove Lite software tool. PC must be connected point to point with Modbus protocol: TeSys T with HMI port TeSys U with LUCM** port. The following schema represents the Tree of installers of the TeSysDtmLibrary. Tesys DTM Library Installer > Tesys U DTM Installer > Tesys T DTM Installer

9.2. TeSysDTMLibrary referenced DTM


Software Component Name Version

TesysdtmLibrary Tesys U Tesys T

V 2.4.1.0 V 2.4.1.0 V 2.4.1.0

9.3. Restrictions 9.3.1 This library release is available in English, French, Italian, Spain and German language only. > DTMs: Tesys U, Tesys T This library release is dedicated to SoMove Lite software running in Microsoft Windows XP Professional SP3 32 bits and Windows7 32 bits operating system > DTMs: Tesys U, Tesys T Depending on amount of data to display value refresh time can take few seconds. > DTMs: Tesys U, Tesys T Depending on the PC load, Start and Stop commands should be separated by significant time > DTMs: Tesys U, Tesys T Supports limited print features: only parameters list is printable. > DTMs: Tesys U, Tesys T

9.3.2

9.3.3 9.3.4

9.3.5

9.4. Known Issues 9.4.1 9.4.2 9.4.3 Some menu items are not greyed even if related command is not contextually available. > DTMs: Tesys U, Tesys T Some tree items and parameter groups remain displayed even if they are empty. > DTMs: Tesys U, Tesys T Depending on the amount of online data exchanges, it may take few seconds to refresh some values. > DTMs: Tesys U, Tesys T Added column during configuration comparison does not come in print/export options. > DTMs: Tesys U, Tesys T Depending upon amount of data transferred, store to device and compare may take few minutes in excess to compare. > DTMs: Tesys U, Tesys T

9.4.4

9.4.5

9.5. Troubleshoot
1. Load from Device - If a load from device action is interrupted by a device power OFF, then the subsequent load from device actions may fail. Resolution:

Power ON the device and try to Load from device again,. If problem persists, then restart SoMove and try to Load from device again. 2. Connection Lost with Tesys T - In case of a "Connection Lost" the device can be connected again by clicking connect button. Resolution: Connect to the device again. 3. Active DTM Warning with Tesys T - Warning "There are Active connections to the DTM, can they be terminated" is shown. Resolution: Click "Yes", close the project and connect again to the device. If an error dialog with ""Configuration you created is not compatible with the drive" is shown click ok, close the project and connect again to the device.

10 SoMove Troubleshoot
1. Connection lost in Serial Communication
In Case of Connection Lost when using Serial Communication, configure the Inter-Char Timeout from the Modbus Driver as follows:

1. Select the Modbus driver from the taskbar. The default settings for Inter-Char Timeout will be automatic.

Fig: 1 2. Select the COM Port to be used and change the Inter-Char Timeout value to higher value. E.g. 50 ms.

Fig: 2 3. Online help: Adobe version 10 and above, the user has to disable the Protected Mode at startup in the Adobe Reader preference: In Adobe Reader X, go to Edit>Preferences>General and uncheck "Enable Protected Mode at startup"