You are on page 1of 2

The Worlds Most Efficient High Capacity Transmission Conductor

Twice the Capacity of ACSR

ACCC

30-40% Reduction in Line Losses


To learn more about why the ACCC conductor has been selected for over 200 projects worldwide, contact CTC Global today.

Proven Reliability Worldwide

2026 McGaw Avenue - Irvine, CA 92614 USA Phone: +1 (949) 428-8500 Fax: +1 (949) 428-8515 www.ctcglobal.com
Copyright CTC Global 2012 ACCC is a registered trademark of CTC Global

The Economics of Efficiency


CTC Global a privately held corporation headquartered in Irvine,
California promotes efficiency, increased capacity and improved reliability of both new and existing transmission systems. CTC Globals principle business is the manufacture and sale of the ACCC core used in the production of ACCC conductor. The company also

Value of Line Loss Reductions


Peak Amps Temperature at peak amps (C) Load Factor MVA Annual Line Losses (MWh) Line Loss Reduction Value of Reduction (at $50/MWh) Value of Reduction per lineal conductor (meter) (foot)

ACSR 1,000 95 53% 398 76,917 ---- ---- ---- ---ACCC 1,000 82 53% 398 56,588 20,329 $1,016,450 $3.39 $1.03

ACSS 1,600 194 53% 637 251,998 ---- ---- ---- ---ACCC 1,600 156 53% 637 179,022 72,976 $3,648,800 $12.16 $3.71

provides ancillary components such as dead-ends and splices, and provides engineering, installation and warranty support for all of its products. All components produced by CTC and its stranding partners are certified to ISO 9001-2008 Standards. CTC Global produces finished conductor in association with a growing team of qualified regional stranding partners. ACCC core is produced, tested and certified at CTC Global and then stranded with trapezoidal shaped aluminum by qualified ACCC conductor licensees who then ship the finished conductor to

Value of Generation Capacity Savings


Peak Amps ACSR ACCC ACSS ACCC 1,000 1,000 1,600 1,600 Temperature at peak amps (C) 95 82 194 156 Load Factor MVA Annual Line Losses (MWh) 76,917 56,588 251,998 179,022 Generation Value of Reduction Capacity to Supply at $1 million/MW Losses (MW) 30.35 22.33 99.43 70.63 ---- $8,020,000 ---- $28,800,000 Value of Reduced Generation per lineal conductor (meter) (foot) ---- $26.73 ---- $96.00 ---$8.15 ---$29.26

53% 53% 53% 53%

398 398 637 637

customers worldwide.

Value of Emission Reductions Increase Capacity without Compromise


The ACCC conductor offers industry-leading capacity and efficiency through any range of operating temperatures compared to any other conductor type of the same diameter and weight. The ACCC conductors high strength and low thermal sag provides planners and engineers an efficient means of increasing capacity - and improving efficiency and reliability - without compromising structural integrity or safe ground clearances.

Improve Reliability & Compliance


The ACCC conductors combination of superior strength, high capacity and low thermal sag make it uniquely suited for addressing issues of reliability and regulatory compliance providing utilities with an effective and economical solution for thermally constrained lines.

Peak Amps

Load Factor

MVA

Line Loss Reduction (MWh)

C02 Reductions (Metric Tons)

SOx Reductions (Metric Tons)

NOx Reductions (Metric Tons)

Value of C02 Reduction per lineal conductor (meter) (foot)

ACSR 1,000 53% 398 ---- ---- ---- ---- ---- ---ACCC 1,000 53% 398 20,329 63,513 290 98.6 $5.29 $1.61

ACSS 1,600 53% 637 ---- ---- ---- ---- ---- ---ACCC 1,600 53% 637 72,976 250,572 1144 389 $20.88 $6.36

CTC Global Technical Support


CTC Globals support staff stands ready to provide project development, design, and installation assistance. The ACCC conductor can be analyzed using any commercially available line design program such as PLS CADD, Sag 10, or CTC Globals own Conductor Comparison & Line Optimization Program (CCP). Please contact support@ctcglobal.com

Assumptions: 100 km (62 mile) 230 kV line; Drake Equivalent Conductors; 53% Load Factor; 30 C Ambient; 2 fps Wind; .5 Emissivity; .5 Absorbtivity; $50/MWh; $1MM/MW; Coal Fired (2.19#/kWh); CO2 $25/MT

Maximize Efficiency and Returns


Increased capacity and a 30% to 40% reduction in line losses under any load condition improve financial returns year after year over the life of the asset. The ACCC conductor operates cooler than any other overhead conductor under any load condition, delivering more power more efficiently with greater pay back.

ACCC The Worlds Most Efficient High Capacity Transmission Conductor