Maintenance Manual of ZXG10-BSC(V2)

Preface
ZXG10 is the GSM mobile communications system independently developed by ZTE Corporation, consisting of the ZXG10-MSS switching subsystem and the ZXG10-BSS base station subsystem. The ZXG10-BSS base station subsystem is in charge of providing and managing wireless transmission system in GSM, made up of the ZXG10-BSC base station controller and the ZXG10-BTS base station transceiver, etc. Whether the ZXG10-BSS base station subsystem can run normally on the network greatly depends on whether the system is in correct usage and maintenance. Therefore, it is especially important to have a good command of correct maintenance methods and be capable enough to handle problems properly as well.
ZXG10-BSC (VB Base Station Controller Maintenance Manual is to guide users on

how to perform the daily maintenance and deal with faults encountered when using ZXG10-BSC (VB base station controller system, mainly with respect to daily maintenance, alarm processing, and operation information processing. This manual is divided into three distinct parts: Part 1: Equipment Maintenance gives you an introduction of how to perform routine maintenance, emergent maintenance and common maintenance. Part II: Troubleshooting lists alarm types, containing detailed information about message alarm code, alarm level, alarm reason, alarm impact, alarm processing time limit, alarm processing flow, etc. Part III: Running Information Processing describes in detail the operation information and processing method about MP, COMM modules. Appendix A: Replacement of Boards and Components provides procedures of replacing boards and components and the cautious items. Appendix B Abbreviations lists all the abbreviated words present in this book to help you use this manual. ZXG10-BSC (VB base station controller is BSC (VB in short.

Maintenance Manual of ZXG10-BSC(V2)

This set of manuals include documents as follows: ZXG10-BSC (VB Base Station Controller Technical Manual ZXG10-BSC (VB Base Station Controller Installation Manual. ZXG10-BSC (VB Base Station Controller Operation Manual

Statement: Since products and technologies keep on developing and upgrading, the information contained herein may not be in perfect compliance with the specific products. Please contact our local offices for updating or renewing information about products.

Maintenance Manual of ZXG10-BSC(V2)

Table of Contents
1 1.1 1.2 1.2.1 1.2.2 1.3 1.4 1.5 1.5.1 1.5.2 2 2.1 2.2 2.2.1 2.2.2 2.2.3 2.2.4 2.2.5 2.3 2.3.1 2.3.2 2.3.3 2.3.4 2.4 2.4.1 2.4.2 2.4.3 2.4.4 2.4.5 2.4.6 2.5 2.5.1 2.5.2 EQUIPMENT MAINTENANCE ..................................................................................................... 1 INTRODUCTION ................................................................................................................................... 1 ROUTINE MAINTENANCE.................................................................................................................... 3 Daily Routine Maintenance............................................................................................................ 3 Periodical Routine Maintenance ................................................................................................... 3 EMERGENT MAINTENANCE ................................................................................................................ 4 COMMON MAINTENANCE MEASURES ............................................................................................... 5 RELATED MAINTENANCE TABLE ........................................................................................................ 7 Routine Maintenance & Operation Record ................................................................................. 7 Emergent Maintenance & Operation Record ............................................................................. 9 TROUBLESHOOTING .................................................................................................................10 ALARM INFORMATION AND HANDLING .............................................................................................10 BSC(V2) EQUIPMENT ALARM .........................................................................................................12 MP Equipment Alarm ....................................................................................................................12 SYCK Equipment Alarm ...............................................................................................................17 Power Supply Equipment Alarm .................................................................................................19 TIC Board Error .............................................................................................................................22 Other Alarms ..................................................................................................................................24 BSC(VB COMMUNICATION ALARM .................................................................................................40 MODULE Communication Alarm ................................................................................................40 LAPD Communication Error ........................................................................................................45 BOARD Communication Alarm ...................................................................................................47 Other Communication Faults ......................................................................................................49 BSC (VB ENVIRONMENTAL ALARM.................................................................................................52 Equipment Room Environmental Temperature Overhigh Alarm...........................................52 Equipment Room Environmental Temperature Overlow Alarm ............................................53 Equipment Room Environmental Humidity Overhigh Alarm..................................................54 Equipment Room Environmental Humidity Overlow Alarm ...................................................55 Equipment Room Infrared Alarm ................................................................................................56 Equipment Room Smog Alarm ...................................................................................................57 GPRS COMMUNICATION FAULT ......................................................................................................58 FRP Communication Alarm .........................................................................................................58 BRP Communication Fault ..........................................................................................................63 Page I of III

Maintenance Manual of ZXG10-BSC(V2) 2.5.3 2.6 2.6.1 2.6.2 2.6.3 2.6.4 2.6.5 2.6.6 2.6.7 2.6.8 2.6.9 2.6.10 2.6.11 2.6.12 2.6.13 2.6.14 2.6.15 2.6.16 2.6.17 2.6.18 2.6.19 2.6.20 2.6.21 2.6.22 2.6.23 2.6.24 2.6.25 2.6.26 2.7 2.7.1 2.7.2 2.7.3 2.7.4 2.7.5 2.8 2.9 Other Communication Faults ......................................................................................................67 BSCV2INFORMATION NOTIFICATION ......................................................................................70 Reset PP board..............................................................................................................................70 Notification of Times of PCM Slide Code on TIC/SMB ..........................................................70 Services Operation Status Notification ......................................................................................70 PP Automatic Loading Failure Notification ...............................................................................71 PP Compulsory Loading Failure Notification ............................................................................71 DSP Automatic Loading Failure Notification ............................................................................71 DSP Compulsory Loading Failure Notification .........................................................................71 Systems Once Encounter of Error ............................................................................................72 Reset Notification of Certain DSP on DRT ...............................................................................72 Receive Alarm on Certain PCM of TIC ......................................................................................72 Receive Frame Architecture Loss of PCM on TIC ..................................................................72 Board Status Change Notification ..............................................................................................72 Changes of Environmental Parameters (Temperature/Humidity/Voltage) ..........................73 Elimination of Maximum Alarm Number Upon POWP-on or Changeover..........................73 Active/Standby GPPs Handover Notification ...........................................................................73 Outdoor BTS Environment Temperature Notification .............................................................73 Notification of Network Communication Status Changes between MP and PCM.............74 BCCH Switchover Failure Notification .......................................................................................74 Bus Code Error Notification .........................................................................................................74 Board Connection Error Notification ..........................................................................................75 Flow Control Startup Notification ................................................................................................75 No Traffic in the Cell ......................................................................................................................75 MP and PCOM Board Handshake Failure ................................................................................75 X.25 Protocol Startup on the PCOM ..........................................................................................76 X.25 Protocol Disable on the PCOM .........................................................................................76 PP Board Version Loading Failure .............................................................................................76 GPRS NOTIFY INFORMATION..........................................................................................................78 Wrong Links Label.........................................................................................................................78 Wrong Entities Label .....................................................................................................................79 Process Number of Transmitting BSSGP Data Packet ..........................................................79 Receive the Status Data Packet of NS Layer Transmitted from the SGSN side ...............79 LAN Error inside SPCU ................................................................................................................80 RUNNING INFORMATION CLASSIFICATION .......................................................................................81 RUNNING INFORMATION OF EACH BOARD ......................................................................................81 Page II of III

Maintenance Manual of ZXG10-BSC(V2) 2.9.1 2.9.2 2.9.3 2.9.4 2.9.5 2.9.6 Running Information of Control Layer Board ...........................................................................82 Board Running Information on Network Switching Layer ......................................................87 TC Unit Panel Indicator Information ...........................................................................................91 GPRSPP Board Running Information ........................................................................................94 POWB Board Running Information ............................................................................................97 Other Boards Running Information ............................................................................................99

APPENDIX A REPLACEMENT OF BOARDS AND COMPONENTS..................................................100 A.1 A.2 A.3 OVERVIEW ......................................................................................................................................100 PROCEDURES OF REPLACING PUBLIC BOARDS...........................................................................100 REPLACEMENT OF OTHER COMPONENTS ....................................................................................102 ABBREVIATIONS .............................................................................................................105

APPENDIX B

Page III of III

Maintenance Manual of ZXG10-BSC(V2)

1
1.1

Equipment Maintenance
Introduction
The purpose of daily maintenance is to completely ensure that the product is in its best condition at any moment so as to guarantee the proper running of the whole system. 1. Maintenance classification The daily maintenance of ZXG10-BSC (VB consists of two types: routine maintenance and emergent maintenance. Routine maintenance is a periodical task. It can be regarded as daily routine operation and periodical work based on the length of each maintenance period. Emergent maintenance refers to emergent measures taken to deal with the sudden failures of equipment, or network adjustment such as equipment failure, user notification fault, and unexpected faults in performing routine maintenance. Since the sudden failures befall unexpectedly and usually have serious effect on the service quality, decisive and cautious processing by maintenance personnel are rather important. Also, detailed records are kept afterwards to help analyze the reason of fault, solve the problem, and avoid encountering similar troubles in the future. 2. Requirements and suggestions

The daily maintenance of ZXG10-BSC (VB equipment is considered as the primary task of the maintenance personnel in the equipment room. Since the sound daily maintenance is a crucial factor of guaranteeing the stable operation of the system in the long term, equipment room maintenance related byelaws should be made to standardize and guide the maintenance personnel. Some basic requirements and suggestions about daily maintenance are described as follows: 1) Maintenance personnel should strictly implement the daily and periodical routine check; Keep detailed records without any careless omissions. 2) Maintenance personnel should guarantee the security, the tidiness, and the fitness of temperature/humidity of the equipment room
Page 1 of 106

Maintenance Manual of ZXG10-BSC(V2)

environment. 3) Maintenance personnel should strictly follow the equipment-operation regulations; Whatever operations and activities (such as arbitrary plug/unplug, reset, initialization, equipment switch-off, data modification, etc.) not included in the daily maintenance scope are all absolutely forbidden. Be sure to wear anti-static wrist straps before touching the hardware system. Ruined or spare parts should be put in the anti-static bags, classified, labeled and stored in safe places. 4) The person in charge of the equipment room maintenance predominates the users account, password and authority used to log on the local O&M console and the network management system. He assigns users account, password and authority to related maintenance personnel according to the authorities and responsibilities specified to the maintenance personnel. 5) Once problems and troubles are detected, the maintenance personnel should take measures immediately to get rid of them. If encountering more serious problems, maintenance personnel should notify it to related executives, and contact local offices of ZTE Corporation for urgent solutions, and keep detailed records afterwards. 6) Maintenance personnel should receive necessary trainings before on duty. Different technical personnel are put in different positions varying with technical grades. 7) Periodically examine and calibrate those common-use tools and instruments to ensure they are in good condition. The equipment room is recommended to have tools and instruments prepared as follows: A Preferable tools and auxiliary materials are recommended as follows: flat-pin/cross-pin screwdrivers, diagonal pliers, nipper pliers, wire strippers, unpacking pliers, electric irons, chip extractors, tweezers, spanners, electric drivers, tape measures, insulating rubberized fabrics, binding strips, etc. B Standby meters are recommended as follows: multi-meter, thermometer, hygrometer, optical power meter, signaling meter,
Page 2 of 106

Maintenance Manual of ZXG10-BSC(V2)

resistance tester, etc. 8) Guarantee the stable and reliable operation of the power supply system; Check the system grounding status periodically. 9) To prevent the wires from damages , periodically check the wires connecting systems to make sure no weighty objects are laying over them.

1.2
1.2.1

Routine Maintenance
Daily Routine Maintenance Daily routine maintenance is to check the running condition of the equipment. 1. Querying Alarm Information By means of faults management system in the ZXG10-OMCR (VB O&M system, the supervision of the entire ZXG10-BSS (VB operation status is enabled. Equipment room watchers should examine site alarms, rack alarms or other alarms via alarm inquiry window, record them in detail and keep constant contact with technical personnel so as to locate and resolve troubles. Refer to ZXG10-BSC (VB Base Station Controller Operation Manual for methods related to alarm information inquiry. 2. Module Running Status View the indicator lights of each module on the rack to see whether their display is all right (See Section 3. B; if any of the alarm lights is on, contact technical personnel immediately so as to relocate and resolve troubles.

1.2.2

Periodical Routine Maintenance 1. Check BSC modules Check the amount, type and version of standing modules once week; make sure their storage conditions comply with requirements; the amount is sufficient and easily available. Remember to check the exchanges and repairs of faulty modules as well.
Page 3 of 106

Maintenance Manual of ZXG10-BSC(V2)

2. Faults statistics Make statistics of faulty modules in detail every week. 3. Hardware test: check once a month. 1) Check whether the power lines are connected stably; Make sure the wires are rusty yet. Check whether the grounding lines are connected stably; Make sure the wires are not rusty yet. Periodically check the system-connecting wires to make sure there are no weighty objects laying over them, thus preventing the wires from damages.

2)

3)

4. Transmission Check the connectors of transmission wires between optical terminals, from the microwave rack to the BSC rack to make sure they still remain fixed without twisted, extruded, distorted or tightened. Test the standing port.

1.3

Emergent Maintenance
Emergent maintenance refers to the immediate measures necessary for dealing with sudden failures of ZXG10-BSC (VB equipment. As the sudden failures turn up unexpectedly and usually have serious effect on the service quality, decisive and cautious processing by maintenance personnel are rather important. Also, detailed records are kept afterwards to serve as reference for avoiding similar troubles in days to come.

In general cases, the processing flow and the processing measures of sudden failures can be classified as follows: 1. Sudden failures and disasters in equipment room 1) Primary faults Power supply system failure; Flood and Fire; Air-conditioning system failure, as a result, temperature and humidity severely exceeds the standard specifications.
Page 4 of 106

Maintenance Manual of ZXG10-BSC(V2)

2) Maintenance measures After viewing the alarm message from the OMCR system of BSS the subsystem, check the equipment room environment immediately, locate the fault and confirm the reason, rapidly resolve the fault and notify it to the higher-level executives. Keep detailed records to help clear out the hidden troubles. 2. Sudden failures of equipment itself 1) Primary faults Include hardware parts, such as damages, designated positions unavailable, poor contact found in modules and unit module. Also included are software parts like disordered data or programs, etc. 2) Maintenance measures
A

Via plug/unplug, partial problems such as designated position unavailable and poor contact can be solved. Or by means of replacement or isolation, you estimate the damages of hardware. Data disorder can be inquired and corrected via operation in the OMCR system of the BSS base station controller subsystem

B Software/ hardware faulty phenomena are quite complicated. If problems remain unresolved even though simple measures listed above have already been taken, please contact technical personnel or local offices of ZTE immediately and notify it to related executives at the same time. Keep records in detail afterwards so as to help clear out similar hidden troubles in the days to come.

1.4

Common Maintenance Measures


In daily maintenance, common measures are classified as follows: 1. Observation This is mainly to locate the trouble via viewing the alarm message from the OMCR management terminal. Observation is a first-of-all method that
Page 5 of 106

Maintenance Manual of ZXG10-BSC(V2)

the maintenance personnel use when encountering troubles. The correct judging of the observed result is a key factor of correctly analyzing and resolving problems. Therefore, maintenance personnel must be quite familiar with indicator lights on each module and be fully aware of the meanings of alarm information at different levels displayed on the management terminal. 2. Plug/unplug At the very beginning of finding faults in a certain module, unclose the fastener on the front panel, then plug/unplug the connector between the module and the external interface so as to remove the faults resulting from improper contact or processor abnormality. 3. Replacement Using a functionally proper module to replace the module to be checked to confirm whether the latter has gone wrong. If plug-unplug method doesnt work, choose the replacement way.
Warning: When plugging/unplugging/replacing modules, refer to Appendix A for cautious items and operation procedures in the case of replacing boards and components.

4. Isolation If only partial system has gone wrong, you isolate this part from related modules or racks to judge whether the fault results from interaction between then. The common isolation way is to self-loop the in/output interface of a certain module so as to isolate and remove the problems of the related system. 5. Self-test When the system or module is powered on again, judge if there is any fault y way of self-test. In normal cases, when a module is powered on and self tested, the indicator lights on its panel will flash regularly. This way will tell whether the module itself is faulty. 6. Press Turn off the power and then press the cable connectors. This will help remove the troubles resulting from improper contact.
Page 6 of 106

Maintenance Manual of ZXG10-BSC(V2)

7. Combination Combining all the methods listed above with ones experience accumulated in routine maintenance can clear whatever faults.

1.5
1.5.1

Related Maintenance Table


Routine Maintenance & Operation Record Table 1-1 shows a daily maintenance record. Table 1-2 is a periodical maintenance record.

Page 7 of 106

Maintenance Manual of ZXG10-BSC(V2)

Table 1-1 Daily Maintenance Record Item Operation Items Running and processing result Operatio Querying Alarm Information n status Module Running Status Table 1-2 Periodical Maintenance Record Item Operation Items Maintenance Running and Operator Period BSC Module Check Fault Statistics Check the power cables connection Check the grounding cables connection Hardware Check Check the cables connecting equipment Check the equipment installation Check the auxiliary equipment Transmission Check the transmission Check BSC module Faults statistics processing Results Remarks Operator Remarks

Page 8 of 106

Maintenance Manual of ZXG10-BSC(V2)

1.5.2

Emergent Maintenance & Operation Record An emergent maintenance record is as Table 1-3 shows:
Table 1-3 Emergent Maintenance Record Office name: Occurring Time: Fault notification source: user call Fault types: Description: alarm system discover in routine maintenance Others Processor: Solution time:

Solution:

Result:

Opinions from the person in charge:

Page 9 of 106

Maintenance Manual of ZXG10-BSC(V2)

2
2.1

Troubleshooting
Alarm Information and Handling
The ZXG10-OMCR (VB fault management system monitors the entire running status of ZXGQO-BSS (VB system in concentrative mode, by testing, notifying and processing the abnormal happenings of telecom networks and environments. These functions are realized via fault alarm and fault diagnosis. The alarm management system is to locate the accurate position of the trouble. By means of relevant judging performance, the display of alarm on the user end interface is enabled, realizing the real-time notification of actual alarms. In terms of real-time property, the alarm issue method is divided into general notification and emergent notification. The former merely indicates the unrepeatable or instantaneous troubles arising while the system is running. Usually, if the notification of this kind of troubles is not so frequent, that means this trouble might be caused by accidentally environmental factors, and the maintenance personnel do not need any processing actions; however, if the notification becomes frequent and even long-playing, it tells that the maintenance personnel must immediately locate the reason and solve it in time. The alarm may last for some time, so, it usually affects the normal services, maintenance and running reliability of the system in different degrees; the alarm can be divided into four levels varying with severity as follows: Principles of rating four levels of alarm are listed in Table 2-1:

Page 10 of 106

Maintenance Manual of ZXG10-BSC(V2)

Table 2-1 Alarm levels Range of services seriously affected Range of equipment security seriously affected Range of system operation reliability seriously affected

Alarm level

Range of system maintainability seriously affected

The whole BSS

The whole BSS

One or more sites

BSC or a site

The whole BSS

The whole BSS

One or more carrier frequencies

One or more carrier frequencies

BSC or a site

BSC or a site

One or more channels

No influence.

One or more carrier frequencies

One or more carrier frequencies

Notes: in the definition of alarm levels, the affected range only refers to the influence on a single item, i.e., the level of a certain alarm can be determined if a certain index such as the reliability and security reaches the specified range. If an alarm item has influence on more than one index, the alarm level may be increased. This chapter discusses the notification code of BSC (2.0) and GPRS, and the reason of alarm information. The processing flow is also included. Please refer to relevant maintenance manuals for the alarm information of BTSMBBS21 and OBTS respectively. Main alarm modules are: MP, COMM, etc. The alarm information, notification information and the processing flow of BSC (VB system are described in detail as follows:

Page 11 of 106

Maintenance Manual of ZXG10-BSC(V2)

2.2

BSC(V2) Equipment Alarm


In the following descriptions, if the alarm reason is defined as unknown, reason code: 10, it shows that the alarm possibly results from various reasons and is difficult to define.

2.2.1 2.2.1.1

MP Equipment Alarm
BSCMP Alarm

1. 2. 3.

Alarm code:0 Alarm level: 2 Alarm cause 1) The opposite end MP powers down or is not installed yet, cause code: 46. The opposite end Watchdog overflows, cause code:48. The opposite end MP software goes wrong, cause code: 49. The standby MP goes wrong, cause code: 50.

2) 3) 4)

4. Effect: If the standby MP goes wrong, the system operation reliability will be seriously reduced. 5. 6. 7. Processing time limit: Instant processing. Processing flow: Power on or reset or replace standby MP. Remarks: None.

Page 12 of 106

Maintenance Manual of ZXG10-BSC(V2)

2.2.1.2

Disk Alarm

1. 2. 3. 51.

Alarm code:1 Alarm level: 2 Alarm cause: The space available of MP runs short, with cause code:

4. Effect: Affects the normal operation of system software, with respect to alarm data, temporary data storage, etc. 5. Processing time limit: Instant processing.

6. Processing flow: Delete the files no more useful on MP, release the disk space to guarantee that the space available accounts for at least one fifth of the whole MP disk space. 7. Remarks: None.

Page 13 of 106

Maintenance Manual of ZXG10-BSC(V2)

2.2.1.3

BSC CPU Bus Alarm

1. 2. 3.

Alarm code: 3 Alarm level: 1 Alarm cause 1) 2) 3) Share memory board bus error, cause code: 56. COMM board bus error, cause code: 57. Unknown, cause code: 10.

4. Effect: The normal operation of BSC system fails, as a result, the system or the board is disabled and the transmission data is in disorder. 5. 6. Processing time limit: Instant processing. Processing flow: 1) 2) 3) 4) 7. Replace the faulty memory board. Replace the faulty COMM board. Replace MP. Replace the backplane at the control layer of BSC rack

Remarks: None.

Page 14 of 106

Maintenance Manual of ZXG10-BSC(V2)

2.2.1.4

Data Loading Error

1. 2. 3.

Alarm code: 4 Alarm level: 2 Alarm cause 1) 2) 3) Database loading errs, with cause code: 58. Database synchronization errs, with cause code: 59. Unknown, cause code: 10.

4. Effect: The normal operation of BSC system is disabled; data transmission is in disorder. 5. 6. Processing time limit: Instant processing. Processing flow: 1) 2) MP reset. If errors still exist after MP is reset, reconfigure and adjust the synchronization data.

7.

Remarks: None.

Page 15 of 106

Maintenance Manual of ZXG10-BSC(V2)

2.2.1.5

CPU Overload of MP

1. 2. 3. 4. 5. 6. 7.

Alarm code: 6 Alarm level: 2 Alarm cause: Unknown, cause code: 10. Effect: Service access is limited. Processing time limit: Instant processing. Processing flow: Contact the local office of ZTE Corporation. Remarks: None.

Page 16 of 106

Maintenance Manual of ZXG10-BSC(V2)

2.2.2 2.2.2.1

SYCK Equipment Alarm


BSC Synchronization Clock (SYCK) Board Alarm (serious)

1. 2. 3.

Alarm code: 0x200 Alarm level: 1 Alarm cause 1) 2) 3) 4) 5) 6) The 8M frame header signal output errs, with cause code: 11. The 8M clock output errs, with cause code: 12. The 16M frame header signal output errs, with cause code: 13. The 16M clock output errs, with cause code: 14. Communication breaks off, with cause code: 1. Power down, with cause code: 2.

4. Effect: Communication is partially instable inside the BSC system, generally accompanied by multiple of other alarms; If no multiple alarms arise, it shows that the faulty part doesnt affect the normal work configured via BSC system for the moment. 5. Processing time limit: If two clock boards encounter alarms at the same time, both should be processed immediately. If merely the active board encounters the alarm, the system will start to use the standby board, but the alarmed clock board must be replaced within three days. As the system can still run in the case of only one clock board, no influences will be brought to the system for the moment. 6. Processing flow: 1) If merely the active board alarms, the active/standby boards will automatically switch off to initiate the standby board. Please give the faulty boards to the local office for immediate replacement. If both boards alarm, orderly replace active/standby boards for immediate measures.

2)

7.

Remarks: None.
Page 17 of 106

Maintenance Manual of ZXG10-BSC(V2)

2.2.2.2

BSC Synchronization Clock (SYCK) Board Alarm (general)

1. 2.

Alarm code: 0x201 Alarm level: 3

3. Alarm cause: D/A conversion goes beyond its range, with cause code: 16. 4. Effect: Interface slip code, error code and out-of-frame possibly cause the alarm; the SS7 and LAPD link err. But they dont affect the normal operation of services in general cases. 5. 6. Processing time limit: Replace them within 15 days. Processing flow: 1) Check the MSC clock source to see whether it deviates; If so, calibrate it immediately. Replace the board.

2) 7.

Remarks: Usually caused by the aging of the clock.

Page 18 of 106

Maintenance Manual of ZXG10-BSC(V2)

2.2.3 2.2.3.1

Power Supply Equipment Alarm


POWB board alarm (serious)

1. 2. 3.

Alarm code: 0x203 Alarm level: 2 Alarm cause 1) 2) 3) 4) 5) 6) Power supply output 5V undervoltage, with cause code: 22. Power supply output 5V overvoltage, with cause code: 28. Power supply output 12V undervoltage, with cause code: 26. Power supply output 12V overvoltage, with cause code: 32. Power supply output -12V undervoltage, with cause code: 27. Power supply output -12V overvoltage, with cause code: 33.

4. Effect: If this fault happens, each board will remain in the status of under or over- voltage. This will seriously affect the life of the board, which will stop working if situation becomes worse. 5. 6. Processing time limit: Instant processing. Processing flow: 1) If both of the active and standby power boards exist at this layer, you should pull out the alarmed board immediately and replace it within 15 days. If only one power board is available at this layer, you should pull out the alarmed board immediately, and unplug a standby board from other layers to plug it into this layer as a temporary substitute. Fill up the vacancies of the power boards in other layers within 15 days.

2)

7.

Remarks: None.

Page 19 of 106

Maintenance Manual of ZXG10-BSC(V2)

2.2.3.2

POWB board alarm (common)

1. 2.

Alarm code: 0x205 Alarm level: 4

3. Alarm cause: The board switch disconnects itself; the board cant supervise; or location unavailable / power down happens, with cause code: 62. 4. Effect: The power boards usually back up each other in active/standby mode; if one of the boards alarm, it is unnecessary to handle it in a hurry. But the alarm will affect the test and maintenance of the power boards. 5. 6. Processing time limit: Be sure of reset within 15 days. Processing flow: 1) Check the power board to see whether it is its position; If not, leave it alone temporarily or shield it. Check whether the COMM cables are connected to this power board; if not, reconnect related cables. Check whether the RS485 cables on the backplane are loose. Check whether the MONI board is faulty; If so, replace the board.

2)

3) 4)

7.

Remarks: None.

Page 20 of 106

Maintenance Manual of ZXG10-BSC(V2)

2.2.3.3

POWP board alarm (common)

1. 2. 3.

Alarm code: 0x206 Alarm level: 1 Alarm cause 1) Neither of the dual lines on the power board works ,with cause code: 152. The POW P fan system errs, with cause code: 153. POWP over/undervoltage, with cause code: The left line of POWP boards stops working, with cause code: 155. The right line of POWP board stops working ,with cause code: 156. 154.

2) 3) 4)

5)

4. 5. 6.

Effect: This error will affect the proper operation and equipment Processing time limit: Instant processing. Processing flow: 1) 2) Check if the power supply is normal. Check whether the RS485 cables on the backplane are loose, if so, fasten the cables. If it is difficult to locate the trouble, contact the local office of ZTE.

security of the BSC system.

3)

7.

Remarks: None.

Page 21 of 106

Maintenance Manual of ZXG10-BSC(V2)

2.2.4 2.2.4.1

TIC Board Error


Trunk Interface Circuit 8M8K Clock Loss

1. 2. 3.

Alarm code: 0x2500 Alarm level: 2 Alarm cause: Unknown, cause code: 10.

4. Effect: The 8M and 8K clock of trunk interface circuit drops, causing the trunk interface circuit to err in communication. If the trunk interface goes wrong, it might lead to failure in partial modules of the BSC system. 5. 6. Processing time limit: Instant processing. Processing flow: 1) Check whether the clock unit works properly. If the clock unit alarms, remove the alarm first. Check whether the backplane cables are normal. If abnormal, handle it immediately. Try to plug and unplug the board once more to see whether the system can recover. If the measures listed above still dont work, contact the related local office of ZTE.

2)

3)

4)

7.

Remarks: None.

Page 22 of 106

Maintenance Manual of ZXG10-BSC(V2)

2.2.4.2

Trunk Interface Circuit 8K Clock Loss

1. 2. 3. 4.

Alarm code: 0x2501 Alarm level: 2 Alarm cause: Unknown, cause code: 10. Effect: The 8K clock of trunk interface circuit drops, causing the trunk

interface circuit to err in communication. If the trunk interface goes wrong, it might lead to failure in partial modules of the BSC system. 5. 6. Processing time limit: Instant processing. Processing flow: 1) 2) Perform self-loop check on corresponding 2M ports. Check whether the clock unit in the BSC system works properly. If the clock unit alarms, remove the alarm first. Check whether the backplane cables are normal. If abnormal, handle it immediately Try to plug and unplug the board once more to see whether the system can recover. If the measures listed above still dont work, replace the board.

3)

4)

5) 7.

Remarks: None.

Page 23 of 106

Maintenance Manual of ZXG10-BSC(V2)

2.2.5 2.2.5.1

Other Alarms
DSNI Network Drive Board Alarm

1. 2. 3.

Alarm code: 0x202 Alarm level: 2 Alarm cause 1) 2) Communication with MP breaks off, with cause code: 1. Power down, with cause code: 2.

4.

Effect: The direct aftereffect is transmission failure in the boards of corresponding positions, in that the communication links of multiple boards disconnect and generate alarm. Processing time limit: Instant processing. Processing flow: 1) If this faulty board is the original active board, the system will automatically switch the standby board into the active board. If the faulty board is the standby one, unplug it first and replace it as soon as possible. If no standby board is available, you should immediately unplug a standby board form other DSNI boards equipped with active/standby boards, and plug it into the position absent from standby board, simultaneously make adjustment at the background.
Warning: Never unplug the DSNI-C board to replace the faulty DSNI board.

5. 6.

2)

7. Remarks: The wobble state and the position unavailable of DSNI board, or the hardware error will result in alarms as well.

Page 24 of 106

Maintenance Manual of ZXG10-BSC(V2)

2.2.5.2

CKI Clock Interface Board Alarm

1. 2. 3. 4.

Alarm code: 0x204 Alarm level: 3 Alarm cause: Power down, with cause code: 2. Effect: The direct aftereffect is that the BSC clock system will use the

SYCK clock source of its own or the clock source synchronized from the MSC system. In this case, the system will occasionally encounter error codes and SS7 error. 5. Processing time limit: If the equipment room doesnt offer BITS clock, just leave as it is. If the BITS clock is available in the equipment, settle it within 7 days. 6. Processing flow: 1) Check whether there is BITS clock and whether the BITS clock source has gone wrong. If the BITS clock is all right, try to plug the CKI board again. If the fault is still there after the CKI board is tightly plugged, then replace it with another board.

2) 3)

7. Remarks: The BITS clock reference loss or the hardware error might generate alarms as well.

Page 25 of 106

Maintenance Manual of ZXG10-BSC(V2)

2.2.5.3

Fan Alarm

1. 2. 3. 4. 5. 6.

Alarm code: 0x207 Alarm level: 2 Alarm cause: The POWP fan system errs, with cause code: 153. Effect: Both of the routine work and the equipment security in the Processing time limit: Instant processing. Processing flow: 1) Check whether the power supply system is normal. If both of the power module and the power supply system are abnormal, handle them immediately. If the trouble can still not be located, contact the local office of ZTE.

whole BSC system will be affected.

2)

7.

Remarks: None.

Page 26 of 106

Maintenance Manual of ZXG10-BSC(V2)

2.2.5.4

MPPP(COMM board between MP and PP) Error

1. 2. 3.

Alarm code: 0x401 Alarm level: 2 Alarm cause 1) 2) Communication breaks off, with cause code: 1. Power down, with cause code: 2.

4. Effect: The MPPP board is usually in active/standby status. If one of the boards errs, it wont affect the system operation but the reliability of the system will be affected. If both MPPP boards go wrong, the operation & maintenance link between MP and relevant PP boards will break off, thus, losing control of relevant PP boards. 5. 6. Processing time limit: Instant processing. Processing flow: 1) 2) Check whether the MPPPP board is powered on. Check whether the clock board generates alarm; If so, remove the clock error first. Reset MPPP board and see whether the fault still exists. Check whether the connection lines at the backplane become loose. If the measures listed above still dont work, replace the board.

3) 4)

5)

7. Remarks: The disconnection between MPPP board and MP, power down, hardware fault, clock loss, out of position and so on will also generate alarms.

Page 27 of 106

Maintenance Manual of ZXG10-BSC(V2)

2.2.5.5

MTP SS7 Board Error

1. 2. 3.

Alarm code: 0x402 Alarm level: 3 Alarm cause 1) 2) Communication breaks off, with cause code: 1. Power down, with cause code: 2.

4. Effect: The MTP board is usually in active/standby status. If one of the boards errs, it wont affect the system operation but the reliability of the system will be affected. If both MTP boards go wrong, the communication link between BSC and MSC systems will break off, resulting in the interrupt of related services of this SS7 board. 5. 6. Processing time limit: Instant processing. Processing flow: 1) 2) Check whether the MTP board is powered on. Check whether the clock board generates alarm; If so, remove the clock error first. Reset MTP board and view whether the fault still exists. Check whether the connection lines at the backplane become loose. If the measures listed above still dont work, replace the board.

3) 4)

5)

7. Remarks: The disconnection between MTP board and MP, power down, hardware fault, clock loss, out of position and so on will also generate alarms.

Page 28 of 106

Maintenance Manual of ZXG10-BSC(V2)

2.2.5.6

MONIBSC MONI BoardError

1. 2. 3.

Alarm code: 0x403 Alarm level: 3 Alarm cause 1) 2) Communication breaks off, with cause code: 1. Power down, with cause code: 2.

4. Effect: The monitoring of these boards such as power supply board, the clock board and the network drive board will be disabled. 5. 6. Processing time limit: Instant processing. Processing flow: 1) Check whether the MONI board is powered on or tightly plugged. Check whether the clock board generates alarm; if so, remove the clock error first. Reset MONI board and view whether the fault still exists. Check whether the connection lines at the backplane become loose. If the measures listed above still dont work, replace the board.

2)

3) 4)

5)

7. Remarks: The disconnection between MONI board and MP, power down, hardware fault, clock loss, out of position and so on will also generate alarms.

Page 29 of 106

Maintenance Manual of ZXG10-BSC(V2)

2.2.5.7

SMEM Share Memory Board Error

1. 2. 3.

Alarm code: 0x404 Alarm level: 2 Alarm cause 1) 2) Communication breaks off, with cause code: 1. Power down, with cause code: 2.

4. Effect: The direct aftereffect is the disconnection between the active and standby MP boards, which generates alarm. 5. 6. Processing time limit: Instant processing. Processing flow: 1) Check whether the SMEM board is powered on or tightly plugged in its position. Reset SMEM board and view whether the fault still exists. Check whether the backplane is normal. If the measures listed above still dont work, replace the board.

2) 3) 4)

7. Remarks: The disconnection between SMEM board and MP, power down, hardware fault, clock loss, out of position and so on will also generate alarms.

Page 30 of 106

Maintenance Manual of ZXG10-BSC(V2)

2.2.5.8

Environmental Monitoring Board (PEPD) Alarm

1. 2. 3.

Alarm code: 0x405 Alarm level: 2 Alarm cause 1) 2) Communication breaks off, with cause code: 1. Power down, with cause code: 2.

4. Effect: it is impossible to monitor the equipment room environment with respect to: temperature, humidity, smog, etc. In this case, the maintainability of the system will be affected. 5. 6. Processing time limit: Instant processing. Processing flow: 1) Check whether the PEPD board is powered on or too tightly plugged in its position. Check whether the clock board generates alarm; If so, remove the clock error first. Check whether the connection lines at the backplane become loose. If the measures listed above still dont work, replace the board.

2)

3)

4)

7. Remarks: The disconnection between PEPD board and MP, power down, hardware fault, clock loss, out of position and so on will also generate alarms.

Page 31 of 106

Maintenance Manual of ZXG10-BSC(V2)

2.2.5.9

LAPD COMM Board Alarm

1. 2. 3.

Alarm code: 0x406 Alarm level: 2 Alarm cause 1) 2) Communication breaks off, with cause code: 1. Power down, with cause code: 2.

4. Effect: The LAPD communication link breaks off; then the communication links of all the sites related to LAPD board stop, as a result, the system operation cant proceed. 5. 6. Processing time limit: Instant processing. Processing flow: 1) Check whether the LAPD board is powered on or too tightly plugged in its position. Check whether the clock board is all right. If not, remove the clock fault first. Reset the LAPD board and see whether the fault still exists. Check whether the connection lines at the backplane become loose. If the measures listed above still dont work, replace the board.

2)

3) 4)

5)

7. Remarks: The disconnection between LAPD board and MP, power down, hardware fault, clock loss, out of position and so on will also generate alarms.

Page 32 of 106

Maintenance Manual of ZXG10-BSC(V2)

2.2.5.10

MPMP Inter-module Communication Board Alarm

1. 2. 3.

Alarm code: 0x407 Alarm level: 1 Alarm cause 1) 2) Communication breaks off, with cause code: 1. Power down, with cause code: 2.

4. Effect: Communication links between modules disconnect. The signaling links of all the related modules break off; as a result, the normal operation of the system is disabled. 5. 6. Processing time limit: Instant processing. Processing flow: 1) Check whether the MPMP board is powered on or too tightly plugged in its position. Check whether the clock board is all right. If not, remove the clock fault first. Reset MPMP board and see whether the fault still exists. Check whether the connection lines at the backplane become loose or improper. If the measures listed above still dont work, replace the board and contact the related local office of ZTE.

2)

3) 4)

5)

7. Remarks: The MPMP board out of position, the hardware fault and the clock loss will also bring about alarms.

Page 33 of 106

Maintenance Manual of ZXG10-BSC(V2)

2.2.5.11

PCOM Board Alarm

1. 2. 3.

Alarm code: 0x408 Alarm level: 1 Alarm cause 1) 2) Communication breaks off, with cause code: 1. Power down, with cause code: 2.

4. 5. 6.

Effect: The cell broadcast short message service breaks off. Processing time limit: Instant processing. Processing flow: 1) Check whether the PCOM board is powered on or tightly plugged in its position. Check whether the clock board generates alarm; If so, remove the clock error first. Reset PCOM board and see whether the fault still exists. Check whether the connection lines at the backplane become loose or improper. If the measures listed above still dont work, replace the board.

2)

3) 4)

5)

7. Remarks: The disconnection between PCOM board and MP, power down, hardware fault, clock loss, out of position and so on will also generate alarms.

Page 34 of 106

Maintenance Manual of ZXG10-BSC(V2)

2.2.5.12

Module Load Control Alarm

1. 2. 3.

Alarm code: 0x2400 Alarm level: 2 Alarm cause 1) 2) The module overload leads to flow control, with cause code: 3. The central module overload leads to flow control, with cause code: 4.

4. 5.

Effect: Service access is limited. Processing time limit: Wait for self-recovery.

6. Processing flow: When load reduces, the system will automatically recover. If the system doesnt recover still, contact the local office of ZTE. 7. RemarksNone.

Page 35 of 106

Maintenance Manual of ZXG10-BSC(V2)

2.2.5.13

PCM Alarm of TIC/SMB/DTI

1. 2. 3.

Alarm code: 0x2402 Alarm level: 3 Alarm cause 1) 2) The receive signal lost, with cause code:150. All of 1s alarm, with cause code: 151.

4. Effect: Related TC units cant work properly, affecting the communication of the SS7 link between BSC and MSC systems. 5. 6. Processing time limit: Wait for self-recovery. Processing flow: 1) 2) 3) Check whether the faulty E1 is properly connected. Check whether the E1 line is intact. Using the intact E1 to self loop the faulty E1, then see if the alarm disappears. If the alarm no longer exists, it means this board is all right, only replace the E1 line. If the measures listed above still dont work, replace the board and contact the related local office of ZTE.

4)

7. Remarks: A certain chip on the TIC/SMB/DTI board or an external connection error may also lead to alarms.

Page 36 of 106

Maintenance Manual of ZXG10-BSC(V2)

2.2.5.14

DSP Alarm on DRT/EDRT/BRP

1. 2. 3. 4. 5. 6.

Alarm code: 0x2403 Alarm level: 3 Alarm cause: Unknown, cause code: 10. Effect: The board will partially work improperly. Processing time limit: Instant processing. Processing flow: 1) 2) Reload correct software version to this DSP. If the alarm still occurs frequently, replace the board.

7. Remarks: It is possibly because of the software error or hardware problem in this DSP.

Page 37 of 106

Maintenance Manual of ZXG10-BSC(V2)

2.2.5.15

COMI Alarm

1. 2. 3. 4.

Alarm code: 0x2532 Alarm level: 2 Alarm cause: Unknown, cause code: 10. Effect: The 8M or 8K clock of the COMM interface board lost, causing

the abnormality of COMM interface board. If the COMM interface board goes wrong, it may result in the partial breakdown of the BSC system. 5. 6. Processing time limit: Instant processing. Processing flow: 1) Check whether the clock unit works properly. If the clock unit alarms, remove the alarm first. Check whether the backplane cables are normal. If abnormal, handle it immediately Try to plug and unplug the board once more to see whether the system can recover. If the measures listed above still dont work, replace the board.

2)

3)

4)

7. Remarks: The software error or hardware problems in this DSP will probably lead to alarm.

Page 38 of 106

Maintenance Manual of ZXG10-BSC(V2)

2.2.5.16

SMB Board Error

1. 2. 3. 4. 5. 6.

Alarm code: 0x2839 Alarm level: 2 Alarm cause: Unknown, cause code: 10. Effect: The BTS related to SMB board works improperly. Processing time limit: Instant processing. Processing flow: 1) Check whether the faulty SMB board is in its position and other related BIPP boards. Check whether the related cables are properly connected or become loose or abnormal. If not, adjust them. Check whether the clock board works properly. Reset the faulty SMB board manually. Start from the background alarm interface to check and confirm whether the SMB board is in proper status. If the alarm no longer exists, it means that fault is removed. If the measures listed above still dont work, replace the board.

2)

3) 4)

5) 7.

Remarks: The disconnection between SMB board and BIPP, power

down, hardware fault, clock loss, out of position and so on will also generate alarms.

Page 39 of 106

Maintenance Manual of ZXG10-BSC(V2)

2.3
2.3.1 2.3.1.1

BSC(VB Communication Alarm


MODULE Communication Alarm
Signaling Point Unreachable

1. 2. 3. 4. 5. 6.

Alarm code: 0x300 Alarm level: 1 Alarm cause: Unknown, cause code: 10. Effect: SS7 initiation is disabled. Processing time limit: Instant processing. Processing flow: 1) Check the signaling link status, corresponding MTP boards, or physical connection lines. Check the office-direction data, MTP data and link connection data to see whether they are correctly configured.

2)

7. Remarks: Problems in data or physical configuration may lead to alarms.

Page 40 of 106

Maintenance Manual of ZXG10-BSC(V2)

2.3.1.2

SS7 L3 Alarm

1. 2. 3. 4. 5. 6.

Alarm code: 0x301 Alarm level: 2 Alarm cause: Unknown, cause code: 10. Effect: One of the SS7 links is disabled. Processing time limit: Instant processing. Processing flow: 1) Check the signaling link status, corresponding MTP boards, or physical connections. Check the office-direction data, MTP data and link connection data to see whether they are correctly configured.

2)

7. Remarks: Poor communication quality of SS7 link, increasingly faulty signaling received, MTP 2 notification of Out of service or physical configuration error, etc. might result in the alarm.

Page 41 of 106

Maintenance Manual of ZXG10-BSC(V2)

2.3.1.3

SS7 SCCP Alarm

1. 2. 3. 4. 5.

Alarm code: 0x302 Alarm level: 2 Alarm cause: Unknown, cause code: 10. Effect: The proper operation of SS7 might be disabled. Processing time limit: Instant processing.

6. Processing flow: Check whether the office-direction data or the network is correctly configured, focusing on the setting of the signaling point. 7. Remarks: When the SCCP sets the status of SSN, if the office-direction is not available according to DPC, this may cause the occurrence of alarm.

Page 42 of 106

Maintenance Manual of ZXG10-BSC(V2)

2.3.1.4

BSC CPU Active/Standby Communication Halt

1. 2.

Alarm code: 0x400 Alarm level: 2

3. Alarm cause: Active/standby communication links break off, with cause code: 53. 4. Effect: Communication or handover between active/standby MPs is disabled, reducing the system reliability. 5. 6. Processing time limit: Instant processing. Processing flow: 1) Check whether the active/standby MPs work properly. If not, remove the fault. Check whether the share memory board works properly. If not, remove the fault. If the measures listed above still dont work, contact the related local office of ZTE.

2)

3)

7. Remarks: If the standby MP doesnt work properly, or if the share memory board encounters an error, there will be alarms.

Page 43 of 106

Maintenance Manual of ZXG10-BSC(V2)

2.3.1.5

BSC Inter-module Communication Failure Alarm

1. 2. 3. 4. 5. 6.

Alarm code: 0x2002 Alarm level: 2 Alarm cause: Unknown, cause code: 10. Effect: A part of modules are disabled. Processing time limit: Instant processing. Processing flow: 1) Check the connection lines between modules to see whether they are correctly connected. If not, correct them. Check and see whether the clock alarms. If it does, remove the alarm first. View the communication interface board. If it raises the alarm, remove it first. If it is still not worked out , contact the local office of ZTE.

2)

3)

4) 7.

Remarks: None.

Page 44 of 106

Maintenance Manual of ZXG10-BSC(V2)

2.3.2 2.3.2.1

LAPD Communication Error


The LAPD Link of TRX and BSC Disconnect

1. 2. 3. 4. 5. 6.

Alarm code: 0x2000 Alarm level: 3 Alarm cause: Unknown, cause code: 10. Effect: All services of this TRU cease. Processing time limit: Instant processing. Processing flow: 1) View this base station and other FUCs to see whether they raise the alarm. If all the FUCs inside the base station raise this alarm, view the base station BIE to see whether it raises the alarm; see whether the EI line is correctly connected and whether the BIU unit, LAPD board in the BSC system raise the alarm. If these alarms exist, remove these faults first. Check the BSC data to see whether they are correct. Switch off BIPP or COMI. 3. If merely the LAPD at one of the TRU layers is disconnected, check if the cable on the backplane is correctly connected. If nothing but the LAPD in one of the TRMs is disconnected, reset the FUC If problems still remain unresolved, contact the local office of ZTE.

2) 3) 4)

5)

6)

7.

Remarks: None.

Page 45 of 106

Maintenance Manual of ZXG10-BSC(V2)

2.3.2.2

COMM Link Disable Between O&M Unit and LAPD of BSC

1. 2. 3. 4. 5. 6.

Alarm code: 0x2001 Alarm level: 2 Alarm cause: Unknown, cause code: 10. Effect: The normal operation and maintenance of the whole site is Processing time limit: Instant processing. Processing flow: 1) View the 2M indicator light of corresponding TIC and see whether the light flashes normally. If the light flashes abnormally, you self loop the BSC system. If the flashing status remains unchanged, it shows that the fault is being transferred or at the BTS side; if the light flashes normally, check the LAPD, TIC or COMI board and see whether they work properly. Check whether the LAPD timeslot of OMU is correctly allocated. Check whether the E1 lines are correctly connected. Check whether the BTS rack is powered on and whether the OMU is properly initiated. Check the BIE of BTS. If it raises the alarm, remove it first. If problems still remain unresolved, contact the local office of ZTE.

affected.

2)

3) 4)

5) 6)

7.

Remarks: None.

Page 46 of 106

Maintenance Manual of ZXG10-BSC(V2)

2.3.3 2.3.3.1

BOARD Communication Alarm


Standby Communication Link Inside BSC System Disable

1. 2.

Alarm code: 0x2003 Alarm level: 4

3. Alarm cause: The fault found in the transmission or board by which the node HDLC link passes, with cause code: 1. 4. 5. 6. Effect: It wont affect the routine function of the base station, but it Processing time limit: Within 24 hours. Processing flow: 1) Check the board by which the HDLC link passes and see whether it works normally. Check all the connection lines (or transmission) by which the HDLC link passes and see whether they are in proper status. If the measures listed above still dont work, contact the related local office of ZTE. can play the role of mutual backup for active and standby.

2)

3)

7.

Remarks: None.

Page 47 of 106

Maintenance Manual of ZXG10-BSC(V2)

2.3.3.2

Board Overtime No Notification

1. 2. 3. 4. 5. 6.

Alarm code: 0x2404 Alarm level: 3 Alarm cause: Unknown, cause code: 10. Effect: It will disable the operation and maintenance of this board. If Processing time limit: Instant processing. Processing flow: 1) Check whether there are still other alarms not removed on this board. If so, remove them first. Reset, plug/unplug the board. Replace the board.

this situation lasts long, it will affect the normal operation of services.

2) 3) 7.

Remarks: The disconnection between PP board and MP, power down,

hardware fault, clock loss, out of position and so on will also generate alarms.

Page 48 of 106

Maintenance Manual of ZXG10-BSC(V2)

2.3.4 2.3.4.1

Other Communication Faults


Disconnect between TIC and MPPP

1. 2. 3.

Alarm code: 0x2507 Alarm level: 3 Alarm cause: Unknown, cause code: 10.

4. Effect: Affect the operation and maintenance of TIC and result in the operation abnormality. 5. 6. Processing time limit: Instant processing. Processing flow: 1) Check whether the PP board is powered on and see whether it raises the alarm. Check whether the clock board generates alarm; If so, remove the clock error first. Reset PP and TIC to view whether the fault still exists. Check whether the connection lines at the backplane become loose. Replace TIC and MPPP boards.

2)

3) 4)

5)

7. Remarks: Possible reasons are disconnection between TIC and MPPP, power down, hardware fault or clock loss.

Page 49 of 106

Maintenance Manual of ZXG10-BSC(V2)

2.3.4.2

Disconnection between COMI and MPPP

1. 2. 3. 4. 5. 6.

Alarm code: 0x2539 Alarm level: 3 Alarm cause: Unknown, cause code: 10. Effect: Affect the operation and maintenance of COMI and result in Processing time limit: Instant processing. Processing flow: 1) Check whether the PP board is powered on and see whether it raises the alarm. Check whether the clock raises the alarm, whether the COMI board raises the alarm for clock loss. If so, remove the clock board fault first. Reset PP and COMI to view whether the fault still exists. Check whether the connection lines at the backplane become loose. If the measures listed above still dont work, replace the COMI board.

the operation abnormality.

2)

3) 4)

5)

7. Remarks: The disconnection between COMI board and BIPP, power down, hardware fault, clock loss, out of position and so on will also generate alarms.

Page 50 of 106

Maintenance Manual of ZXG10-BSC(V2)

2.3.4.3

Disconnection between DRT/EDRT and MPPP

1. 2. 3. 4.

Alarm code: 0x256BDRT; 0x259DEDRT; Alarm level: 3 Alarm cause: Unknown, cause code: 10. Effect: The communication between DRT/EDRT and MPPP fails,

impacting the operation and maintenance management of DRT/EDRT. If this case goes on, the normal operation of this system will be disabled. 5. 6. Processing time limit: Instant processing. Processing flow: 1) 2) Check whether the MPPP board raises the alarm. Check whether the clock raises the alarm, whether the DRT/EDRT board raises the alarm for clock loss. If so, remove the clock board fault first. Reset, plug/unplug the related MPPP and DRT/EDRT; See whether they are faulty. Check whether the connection lines at the backplane become loose. If the measures listed above still dont work, replace the board.

3)

4)

5)

7. Remarks: The disconnection between DRT/EDRT board and TCPP, power down, hardware fault, clock loss, out of position and so on will also generate alarms.

Page 51 of 106

Maintenance Manual of ZXG10-BSC(V2)

2.4

BSC (VB Environmental Alarm


Environmental alarms listed in the following are all found in modules.

2.4.1

Equipment Room Environmental Temperature Overhigh Alarm 1. 2. 3. Alarm code: 0x2405 Alarm level: 2 Alarm cause: Unknown, cause code: 10.

4. Effect: The equipment will work abnormally. If the alarm lasts long, the equipment might be damaged. 5. 6. Processing time limit: Instant processing. Processing flow: 1) Check whether there is fire alarm. If there is, remove the fire alarm first. Check if the air conditioner is normal. If it is a false alarm, it might be because the temperature range is not set properly. If the temperature range is set properly, then check whether the temperature/humidity sensor is faulty. If the problem is still unable to be located, contact the local office of ZTE.

2) 3)

4)

5)

7.

Remarks: None.

Page 52 of 106

Maintenance Manual of ZXG10-BSC(V2)

2.4.2

Equipment Room Environmental Temperature Overlow Alarm 1. 2. 3. Alarm code: 0x2406 Alarm level: 2 Alarm cause: Unknown, cause code: 10.

4. Effect: The equipment will work abnormally. If the alarm lasts long, the equipment might be damaged. 5. 6. Processing time limit: Instant processing. Processing flow: 1) 2) Check if the air conditioner is normal. If it is a false alarm, it might be because the temperature range is not set properly. If the temperature range is set properly, check whether the temperature/humidity sensor is faulty. If the problem location is still unavailable, contact the local office of ZTE.

3)

4)

7.

Remarks: None.

Page 53 of 106

Maintenance Manual of ZXG10-BSC(V2)

2.4.3

Equipment Room Environmental Humidity Overhigh Alarm 1. 2. 3. Alarm code: 0x2407 Alarm level: 2 Alarm cause: Unknown, cause code: 10.

4. Effect: The equipment will work abnormally. If the alarm lasts long, the equipment might be damaged. 5. 6. Processing time limit: Instant processing. Processing flow: 1) 2) Check if the humid extractor is normal. If it is a false alarm, it might be because the humidity range is not set properly. If the temperature range is set properly, check whether the temperature/humidity sensor is faulty. If the alarm is true and still exists, lower the humidity. If the problem location is still unavailable, contact the local office of ZTE.

3)

4) 5)

7.

Remarks: None.

Page 54 of 106

Maintenance Manual of ZXG10-BSC(V2)

2.4.4

Equipment Room Environmental Humidity Overlow Alarm 1. 2. 3. Alarm code: 0x2408 Alarm level: 2 Alarm cause: Unknown, cause code: 10.

4. Effect: The equipment will work abnormally. If the alarm lasts long, the equipment might be damaged. 5. 6. Processing time limit: Instant processing. Processing flow: 1) 2) Check if the humid adding system is normal. If it is a false alarm, it might be because the humidity range is not set properly If the temperature range is set properly, then check whether the temperature/humidity sensor is faulty. If the alarm is true and still exist, raise the humidity. If the problem location is still unavailable, contact the local office of ZTE.

3)

4) 5)

7.

Remarks: None.

Page 55 of 106

Maintenance Manual of ZXG10-BSC(V2)

2.4.5

Equipment Room Infrared Alarm 1. 2. 3. Alarm code: 0x2409 Alarm level: 1 Alarm cause: Unknown, cause code: 10.

4. Effect: If the environmental heat objects are located, it shows that human beings, animals or other heat sources have entered the room. If the equipment is not spoiled, it wont impact the operation. 5. 6. Processing time limit: Instant processing. Processing flow: 1) View the operation record. If it is due to the maintenance personnel who forget to close the alarm, it is unnecessary to handle it. If uncommitted personnel have entered the room, check whether the equipment parameters are modified and whether the equipment is affected. If the problem is still unable to be located, contact the local office of ZTE.

2)

3)

7.

Remarks: None.

Page 56 of 106

Maintenance Manual of ZXG10-BSC(V2)

2.4.6

Equipment Room Smog Alarm 1. 2. 3. Alarm code: 0x204A Alarm level: 1 Alarm cause: Unknown, cause code: 10.

4. Effect: If the air purity around the BSC equipment is poor, there might flow heavy smog or dust. If the dust is too heavy, it might impact the lifespan of the equipment. 5. 6. Processing time limit: Instant processing. Processing flow: 1) 2) Check whether there is smog or fire alarm. If there is no smog, the alarm is possibly caused by the overmuch grain floating in the air. In this case, you take measures to purify the air as much as possible or shield this alarm in line with the equipment room environment. If the problem is still unable to be located, contact the local office of ZTE.

3)

7.

Remarks: None.

Page 57 of 106

Maintenance Manual of ZXG10-BSC(V2)

2.5
2.5.1 2.5.1.1

GPRS Communication Fault


FRP Communication Alarm
FRP 8M8K Clock Loss

1. 2. 3. 4.

Alarm code: 0x7000 Alarm level: 2 Alarm cause: Unknown, cause code: 10. Effect: The 8M and 8K clock on the FRP board loss results in the

abnormality of communication. If FRP fails, partial modules of BSC system will fail to run properly. 5. 6. Processing time limit: Instant processing. Processing flow: 1) Check whether the clock unit in the BSC system works properly. If the clock unit alarms, remove the alarm first. Check whether the connection lines at the backplane of BSC become loose. Try to plug and unplug the board once more to see whether the fault can be removed. If the measures listed above still dont work, replace the board.

2)

3)

4) 7.

Remarks: None.

Page 58 of 106

Maintenance Manual of ZXG10-BSC(V2)

2.5.1.2

FRP 8K Clock Loss

1. 2. 3. 4.

Alarm code: 0x7001 Alarm level: 2 Alarm cause: Unknown, cause code: 10. Effect: The 8M and 8K clock on the FRP board loss results in the

abnormality of communication. If FRP fails, partial modules of BSC system will fail to run properly. 5. 6. Processing time limit: Instant processing. Processing flow: 1) Check whether the clock unit works properly. If the clock unit alarms, remove the alarm first. Check whether the backplane cables are normal. If abnormal, handle it immediately Try to plug and unplug the board once more to see whether the fault can be removed. If the measures listed above still dont work ,contact the related local office of ZTE.

2)

3)

4)

7.

Remarks: None.

Page 59 of 106

Maintenance Manual of ZXG10-BSC(V2)

2.5.1.3

FRP Boards HDLC Communication Interrupt

1. 2. 3. 4. 5. 6.

Alarm code: 0x7007 Alarm level: 2 Alarm cause: Unknown, cause code: 10. Effect: Affect the operation and maintenance of this board. If this Processing time limit: Instant processing. Processing flow: 1) Check whether there are still other alarms not removed on this board. If so, remove them first. Reset this board. If the measures listed above still dont work, contact the related local office of ZTE.

effect continues, the services operation will be spoiled.

2) 3)

7.

Remarks: None.

Page 60 of 106

Maintenance Manual of ZXG10-BSC(V2)

2.5.1.4

NSVC Fault

1. 2. 3.

Alarm code: 0x7008 Alarm level: 3 Alarm cause: 1) The NSVCI in the received reset data package errs, with cause code: 160. The NSEI in the received reset data package errs, with cause code: 161. No reply at the SGSN side; Cause code:162.

2)

3)

4. Effect: If merely one individual NSVC link disconnects, the data on this faulty link will be shared by other links. If all NSVC links disconnect, the Gb port communication will be disabled. 5. 6. Processing time limit: Instant processing. Processing flow: 1) Check the carrier channel on this channel and see whether it works properly. Check whether the SGSN is configured in the same manner as is the NSVC of the BSC system. Reset the FRP board.

2)

3) 7.

Remarks: None.

Page 61 of 106

Maintenance Manual of ZXG10-BSC(V2)

2.5.1.5

Frame Trunk PVC Communication Fault

1. 2. 3. 4. 5. 6.

Alarm code: 0x7009 Alarm level: 2 Alarm cause: Gb port PVC communication errs; cause code: 163. Effect: PVC acts as the carrier channel of NSVC. The PVC error Processing time limit: Instant processing. Processing flow: 1) Check whether the E1 line is correctly connected into the Gb port. Check whether the DLCI of PVC is correctly configured.

might lead to failure of one or multiple NSVC links.

2) 7.

Remarks: None.

Page 62 of 106

Maintenance Manual of ZXG10-BSC(V2)

2.5.2 2.5.2.1

BRP Communication Fault


BRP Boards 8M8K Clock Loss

1. 2. 3.

Alarm code: 0x7100 Alarm level: 2 Alarm cause: Unknown, cause code: 10.

4. Effect: The 8M and 8K clock on the BRP board loss results in the abnormality of communication. If BRP fails, partial modules of the BSC system will fail to run properly. 5. 6. Processing time limit: Instant processing. Processing flow: 1) Check whether the clock unit works properly. If the clock unit alarms, remove the alarm first. Check whether the backplane cables are normal. If abnormal, handle it immediately Try to plug and unplug the board once more to see whether the fault can be removed. If the measures listed above still dont work, replace the board.

2)

3)

4) 7.

Remarks: None.

Page 63 of 106

Maintenance Manual of ZXG10-BSC(V2)

2.5.2.2

BRP Boards 8K Clock Loss

1. 2. 3. 4.

Alarm code: 0x7101 Alarm level: 2 Alarm cause: Unknown, cause code: Effect: The 8M and 8K clock on the BRP board loss results in the

abnormality of communication. If BRP fails, partial modules of BSC system will fail to run properly. 5. 6. Processing time limit: Instant processing. Processing flow: 1) Check whether the clock unit works properly. If the clock unit alarms, remove the alarm first. Check whether the backplane cables are normal. If abnormal, handle it immediately Try to plug and unplug the board once more to see whether the system can recover. If the measures listed above still dont work, replace the board.

2)

3)

4) 7.

Remarks: None.

Page 64 of 106

Maintenance Manual of ZXG10-BSC(V2)

2.5.2.3

BRP Boards HDLC Communication Interrupt

1. 2. 3. 4. 5. 6.

Alarm code: 0x7107 Alarm level: 3 Alarm cause: Unknown, cause code: 10. Effect: It will disable the operation and maintenance of this board. If Processing time limit: Instant processing. Processing flow: 1) Check whether there are still other alarms not removed on this board. If so, remove them first. Check whether related cables become loose or abnormal. Reset boards. If the measures listed above still dont work, contact the related local office of ZTE.

the alarm lasts long, it will affect the normal operation of services.

2) 3) 4)

7.

Remarks: None.

Page 65 of 106

Maintenance Manual of ZXG10-BSC(V2)

2.5.2.4

UDP Ethernet Communication Interrupt between BRP board and MP

1. 2. 3. 4. 5. 6.

Alarm code: 0x710A Alarm level: 3 Alarm cause: Unknown, cause code: 10. Effect: The data packet communication of this board is disabled. If Processing time limit: Instant processing. Processing flow: 1) Check whether there are still other alarms not removed on this board. If so, remove them first. Reset boards. Check whether the HMS communicates with the MP properly. Check whether the two Ethernet lines are correctly connected behind MP. If the measures listed above still dont work, contact the related local office of ZTE.

the alarm lasts long, it will affect the operation of services.

2) 3) 4)

5)

7.

Remarks: None.

Page 66 of 106

Maintenance Manual of ZXG10-BSC(V2)

2.5.3 2.5.3.1

Other Communication Faults


UDP Ethernet Communication Disable between PUC boards

1. 2. 3.

Alarm code: 0x7208 Alarm level: 3 Alarm cause: Unknown, cause code: 10.

4. Effect: Data packets communication between SPCUs is disabled, affecting the system operation. 5. 6. Processing time limit: Instant processing. Processing flow: 1) 2) 3) Reset PUC boards. View whether the lines between PUCs are correctly connected. If the measures listed above still dont work, contact the related local office of ZTE.

7.

Remarks: None.

Page 67 of 106

Maintenance Manual of ZXG10-BSC(V2)

2.5.3.2

UDP Ethernet Communication Interrupt between PUC and GDPP

1. 2. 3. 4. 5. 6.

Alarm code: 0x7209 Alarm level: 3 Alarm cause: Unknown, cause code: 10. Effect: Data packets communication both inside GDPP and between Processing time limit: Instant processing. Processing flow: 1) 2) 3) 4) Reset PUC boards. Check whether related cables become loose or abnormal. Check whether the backplane is normal. If the measures listed above still dont work, contact the related local office of ZTE.

SPCUs is disabled, affecting the system operation.

7.

Remarks: None.

Page 68 of 106

Maintenance Manual of ZXG10-BSC(V2)

2.5.3.3

LAN Error Between SPCUs of HMS Board

1. 2. 3. 4. 5. 6.

Alarm code: 0x7400 Alarm level: 2 Alarm cause: Unknown, cause code: 10. Effect: Communication between SPCUs is disabled, possibly Processing time limit: Instant processing. Processing flow: 1) 2) Make sure that at least two SPCUs work properly. If the measures listed above still dont work, contact the related local office of ZTE.

reducing the system reliability.

7.

Remarks: None.

Page 69 of 106

Maintenance Manual of ZXG10-BSC(V2)

2.6

BSCV2Information Notification
The concept of information notification is described as this: if the system encounters unrepeatable or instantaneous errors, some of which wait for the system self recovery instead of being handled while other faults need maintenance personnels intervention by taking some measures. If the system still remains disabled for a long time, contact the local office of ZTE. Since part of the reasons cant be located by the system, the notified cause code is 10, unless specifically noted, specific causes can be decided on actual situation.

2.6.1

Reset PP board 1. 2. 3. 4. 5. Notification code: 0x2300 Relative components: PP Notified cause and cause code: Unknown, cause code: 10. Solution: None. Remarks: None.

2.6.2

Notification of Times of PCM Slide Code on TIC/SMB 1. 2. 3. 4. 5. Notification code: 0x2306 Relative components: TIC/SMB Notified cause and cause code: Unknown, cause code: 10. Solution: Check lines or self loop to test the code error rate. Remarks: None.

2.6.3

Services Operation Status Notification 1. 2. 3. 4. Notification code: 0x2307 Relative components: MP Notified cause and cause code: Unknown, cause code: 10. Solution: None.

Page 70 of 106

Maintenance Manual of ZXG10-BSC(V2)

5. 2.6.4

Remarks: None.

PP Automatic Loading Failure Notification 1. 2. 3. 4. 5. Notification code: 0x2308 Relative component: BOARD Notified cause and cause code: Unknown, cause code: 10. Solution: None. Remarks: None.

2.6.5

PP Compulsory Loading Failure Notification 1. 2. 3. 4. 4. Notification code: 0x2309 Relative component: BOARD Notified cause and cause code: Unknown, cause code: 10. Solution: None. Remarks: None.

2.6.6

DSP Automatic Loading Failure Notification 1. 2. 3. 4. 5. Notification code: 0x230A Relative component: BOARD Notified cause and cause code: Unknown, cause code: 10. Solution: None. Remarks: None.

2.6.7

DSP Compulsory Loading Failure Notification 1. 2. 3. 4. 5. Notification code: 0x230B Relative component: BOARD Notified cause and cause code: Unknown, cause code: 10. Solution: None. Remarks: None.

Page 71 of 106

Maintenance Manual of ZXG10-BSC(V2)

2.6.8

Systems Once Encounter of Error 1. 2. 3. 4. 5. Notification code: 0x230C Relative component: MP Notified cause and cause code: Unknown, cause code: 10. Solution: Contact the local office of ZTE Corporation. Remarks: None.

2.6.9

Reset Notification of Certain DSP on DRT 1. 2. 3. 4. 5. Notification code: 0x230D Relative component: DRT/EDRT Notified cause and cause code: Unknown, cause code: 10. Solution: None. Remarks: None.

2.6.10

Receive Alarm on Certain PCM of TIC 1. 2. 3. 4. 5. Notification code: 0x230E Relative component: TIC Notified cause and cause code: Unknown, cause code: 10. Solution: Check the transmission or opposite-end equipment. Remarks: None.

2.6.11

Receive Frame Architecture Loss of PCM on TIC 1. 2. 3. 4. 5. Notification code: 0x230F0x2310 Relative component: TIC Notified cause and cause code: Unknown, cause code: 10. Solution: Check the E1 interface and transmission lines. Remarks: None.

2.6.12

Board Status Change Notification 1. Notification code: 0x2311


Page 72 of 106

Maintenance Manual of ZXG10-BSC(V2)

2. 3. 4. 5. 2.6.13

Relative component: BOARD Notified cause and cause code: Unknown, cause code: 10. Solution: None. Remarks: None. Parameters

Changes of Environmental (Temperature/Humidity/Voltage) 1. 2. 3. 4. 5. Notification code: 0x2312 Relative component: MODULE

Notified cause and cause code: Unknown, cause code: 10. Solution: Check the environment related. Remarks: None. Maximum Alarm Number Upon POWP-on or

2.6.14

Elimination of Changeover 1. 2. 3. 4.

Notification code: 0x2313 Relative component: MODULE Notified cause and cause code: Unknown, cause code: 10. Solution: None.
5. Remarks: None.

2.6.15

Active/Standby GPPs Handover Notification 1. 2. 3. 4. Notification code: 0x2314 Relative component: GPP Notified cause and cause code: Unknown, cause code: 10. Solution: None.
5. Remarks: None.

2.6.16

Outdoor BTS Environment Temperature Notification 1. 2. Notification code: 0x2315 Relative component: SITE
Page 73 of 106

Maintenance Manual of ZXG10-BSC(V2)

3. 4.

Notified cause and cause code: Unknown, cause code: 10. Solution: Check the environment of the site.
5. Remarks: None.

2.6.17

Notification of Network Communication Status Changes between MP and PCM 1. 2. 3. 4. Notification code: 0x2316 Relative component: MODULE Notified cause and cause code: Unknown, cause code: 10. Solution: None.
5. Remarks: None.

2.6.18

BCCH Switchover Failure Notification 1. 2. 3. 5. Notification code: 0x2317 Relative component: MODULE Notified cause and cause code: BCCH switchover fails; cause code:

4. Solution: Check the BCCH carrier frequency and the connection of BCCH carrier frequency.
5. Remarks: None.

2.6.19

Bus Code Error Notification 1. 2. 3. Notification code: 0x2318 Relative component: BOARD Notified cause and cause code: 1) Odd and even check fails; cause code: 17. 2) Bus error; cause code: 18. 3) External clock ceases; cause code: 19. 4) Internal clock ceases; cause code: 20.

Page 74 of 106

Maintenance Manual of ZXG10-BSC(V2)

4.
5.

Solution: Filter is needed,


Remarks: None.

2.6.20

Board Connection Error Notification 1. 2. 3. 4. Notification code: 0x2319 Relative component: BOARD Notified cause and cause code: Unknown, cause code: 10. Solution: Check data configuration or board.
5. Remarks: None.

2.6.21

Flow Control Startup Notification 1. 2. 3. 4.


5.

Notification code: 0x231A Relative component: MODULE Notified cause and cause code: Unknown, cause code: 10. Solution: None.
Remarks: None.

2.6.22

No Traffic in the Cell 1. 2. 3. 10. 4.


5.

Notification code:0x231B Relative component: FU Notified cause and cause code: The cell has no traffic; cause code: Solution: None.
Remarks: None.

2.6.23

MP and PCOM Board Handshake Failure 1. 2. Notification code: 0x231C Relative component: PCOM

3. Notified cause and cause code: The PCOM board runs improperly; MP errs in handshake with the PCOM board, with cause code: 10. 4. Solution: Check the board status.
Page 75 of 106

Maintenance Manual of ZXG10-BSC(V2)

5. 2.6.24

Remarks: None.

X.25 Protocol Startup on the PCOM 1. 2. Notification code: 0x231D Relative component: PCOM

3. Notified cause and cause code: The X.25 Protocol starts up on the PCOM, with cause code: 10. 4. 5. 2.6.25 Solution: None. Remarks: None.

X.25 Protocol Disable on the PCOM 1. 2. Notification code: 0x231E Relative component: PCOM

3. Notified cause and cause code: The X.25 Protocol disables on the PCOM, with cause code: 10. 4. 5. 2.6.26 Solution: None. Remarks: None.

PP Board Version Loading Failure 1. Notification code: 0x231F

2. Relative component: BOSNAIPPBIPPTCPPNSPPFSPP DRTEDRTDTISMBSMT1SMT2PUCBRPFRPGIPP. 3. Notified cause and cause code: 1) PP response overtime, with cause code: 220. 2) File no exist; cause code: 221. 3) File length error; cause code: 222. 4) File check error; cause code: 223. 5) Accessing to foreground database fails; cause code: 224. 6) Deletion of file fails; cause code: 225.
Page 76 of 106

Maintenance Manual of ZXG10-BSC(V2)

7) Background message entity parameter error; cause code: 226. 8) It is not the command of the reset BSC board; cause code: 227. 9) Modifying of file fails; cause code: 228. 10) Active/standby MP communication breaks off, with cause code: 229. Application program check error; cause code: 300. FLASH removal error; cause code: 301. FLASH write error; cause code: 302. FLASH read error; cause code: 303. BOOT check error; cause code: 304. Parameter area check error; cause code: 305. Download data check error; cause code: 306. Data download overtime; cause code:307. Edge error; cause code:308. Version type error; cause code: 309. Version error; cause code: 310. Version too long; cause code: 311. Version length error; cause code: 312. Version request serial number error; cause code: 313.

11) 12) 13) 14) 15) 16) 17) 18) 19) 20) 21) 22) 23) 24)

25)This version does not exist; cause code: 314. 4. Solution: Make adjustment based on cause code. 1) PP response overtime: Check whether the boards run normally. 2) File does not exist: Check whether the background has entry version
Page 77 of 106

Maintenance Manual of ZXG10-BSC(V2)

and whether the version file exists. Otherwise, you reenter or wait for 2 or 3 minutes before the file is automatically transferred onto the MP 3) File length error: Use the correct version file or reenter the version. 4) File check and error: Use the correct version file or reenter the version. 5) Accessing to the foreground database fails: Check if the version configurations are correct. 6) Application program check error: Check if the version files are correct. 7) Flash removal error: Reload. If it still doesnt work, replace the board. 8) Flash write error: Reload. If it still doesnt work, replace the board. 9) Flash read error: Reload. If it still doesnt work, replace the board. 10) 11) 12) 13) 5. Version type error: Check if the version files are correct. Version error: Check if the version files are correct. Version too long: Check if the version files are correct. Version length error: Check if the version files are correct. Remarks: None.

2.7
2.7.1

GPRS Notify Information


Wrong Links Label 1. 2. 3. Notification code: 0x7A00 Relative component: FRP Notified cause and cause code: The NSVC link receives wrong links

label; cause code: 164. 4. Solution: First check whether the NSVCI at the BSC side is configured in the same manner as the NSVCI at the SGSN side. If it is all right, check whether the E1 line is wrongly connected.
Page 78 of 106

Maintenance Manual of ZXG10-BSC(V2)

5. 2.7.2

Remarks: None.

Wrong Entities Label 1. 2. Notification code: 0x7A01 Relative component: FRP

3. Notified cause and cause code: The NSVC link receives a wrong entity label; cause code: 165. 4. Solution: First check whether the NSVCI at the BSC side is configured in the same manner as the NSVCI at the SGSN side. If it is all right, check whether the E1 line is wrongly connected. 5. 2.7.3 Remarks: None.

Process Number of Transmitting BSSGP Data Packet 1. 2. 3. Notification code: 0x7A02 Relative component: FRP Notified cause and cause code: The BRP board route error; cause

code: 166. 4. Solution: Make sure that you reset the signaling BVC of this cell provided that the data in the database table is correct a. 5. 2.7.4 Remarks: None.

Receive the Status Data Packet of NS Layer Transmitted from the SGSN side 1. 2. 3. Notification code: 0x7A03 Relative component: FRP Notified cause and cause code: 1) Transmission network error; cause code: 170. 2) Background operation and maintenance; cause code: 171. 3) Equipment error, cause code: 172. 4) Link blocked; cause code: 173.
Page 79 of 106

Maintenance Manual of ZXG10-BSC(V2)

5) Link label VCI error; cause code: 174. 6) Receive faulty BVCI label; cause code: 175. 7) PDU solecism; cause code: 178. 8) Receive the unexpected PDU; cause code: 180. 9) Unknown PDU type; cause code: 181. 10) 11) Illegal message unit; cause code: 182. Loss of important message unit; cause code:183.

4. Solution: Against (A, (B and (C, check whether the corresponding

NSVC links are normal. Or manually reset it from the background if necessary. Against (D, you check whether the NSVC status at the board complies with that of the background database. Against (E and (F, you check whether the background configuration is wrong; If it is correct, you can reset manually the corresponding NSVC and BVCI from the background. Against from (G to (1A, clarify the transmitted NS PDU en/decode errors. If the operations mentioned above still dont work against (A- (F, reset the FRP board or reinitiate P0. 5. 2.7.5 Remarks: None.

LAN Error inside SPCU 1. 2. 3. Notification code: 0x7A04 Relative component: PUC Notified cause and cause code: Unknown, cause code: 10.

4. Solution: Check whether the network goes wrong or changes over to HMS. 5. Remarks: The active PUC tests it and notifies the fault.

Page 80 of 106

Maintenance Manual of ZXG10-BSC(V2)

2.8

Running Information Classification


The ZXG10-BSC (VB running information is originated from the panel indicator lights on such modules as MP, COMM. By giving different definitions to the display of indicator lights, the running status of equipment can be located. Please refer to relevant maintenance manuals for the running information of BTSMBBS21 and OBTS . Based on the board types, the running information can be classified into six types as follows: control layer board, network switching layer board, TC unit, GPRSPP board, power supply board, and other boards.

2.9

Running Information of Each Board


In the following, the fast on/out of indicator lights are defined as 5 times per second, namely the interval between on and out of the indicator lights is 100ms. The slow flash takes place once per second, namely the interval between on and out of the lights is 500ms. Unless specially noted, the indicator lights, switches on the panel are orderly arrayed from the top to the bottom, numbered in 1, 2, 3

Page 81 of 106

Maintenance Manual of ZXG10-BSC(V2)

2.9.1

Running Information of Control Layer Board 1. Running Information of MP Board

There are 4 indicator lights and 3 switches on the MP board as Table 3-1 shows:
Table 3-1 MP Indicator Light Names and Their Meanings Position 1 2 Name HL1 HL2 Descript ion Green Red Meaning Run status Board failure The board is 3 HL3 Green in status The board is 4 HL4 Green in standby status Unlock 5 SW1 Switch button switchoff switch Unlock 6 SW2 Switch button reset switch Lock-button 7 SW3 Switch power supply switch
Note: There is a key interface and a monitor interface on the MP board applied in the software version debugging.

Work mode Slowly flash if the board runs normally The light remains on in the case of board error The light remains on if the board is in active status. The light remains on if the board is in standby status. Press this switch to changeover between active and standby

active

Press this button to trigger the board for reset. Press it, power on; flip it, power down.

Page 82 of 106

Maintenance Manual of ZXG10-BSC(V2)

2.

Running information of SMEM Board

There are 2 indicator lights on the SWEM board as Table 3-2 shows:
Table 3-2 SMEM Indicator Light Names and Their Meanings Position 1 2 Name HL1 HL2 Description Green Red Meanings Run status: Board failure normally. The light remains on if the board errs. Work mode Flash slowly if the board runs

3.

COMM (MPPP/MPMP) Board Running Information

There are 2 indicator lights and 1 switch on the COMMMPPP/MPMP board as Table 3-3 shows:
Table 3-3 COMMMPPP/MPMPIndicator Light Names and Their Meanings Position 1 Name HL1 Description Green Meanings Run status: Work mode Flash slowly: Running properly Flash simultaneously with the alarm light: The board errs, e.g. clock loss. 2 HL2 Red Board failure Unlock 3 SW1 Switch button reset switch Out: Running Flash simultaneously with the running light: The board errs, e.g. clock loss. Press this button to trigger the board for reset.

Page 83 of 106

Maintenance Manual of ZXG10-BSC(V2)

4.

COMM (NO.G Board Running Information

There are 2 indicator lights and 1 switch on the COMM NO.7 board as Table 3-4 shows:
Table 3-4 COMMNO.7Indicator Light Names and Their Meanings Position 1 Name HL1 Description Green Meanings Run status: Work mode Flash slowly: The SS7 link disconnected. Flash fast: The No.7 link is normal Remain on: Running 2 HL2 Red Board failure nlock button reset switch Flash slowly: The board errs, e.g. clock loss. 3 SW1 Switch Press this button to trigger the board for reset.

5.

ECOM (NO.G Board Running Information

There are 2 indicator lights and 1 switch on the ECOMNO.7 board as Table 3-5 shows:
Table 3-5 ECOMNO.7Indicator Light Names and Their Meanings Positio n Name Description Meanings Flash fast: Running Flash slowly: If the red light is on, the SS7 link 1 HL1 Green Run status: disconnects; If the green light flashes simultaneously with the alarm light, it means that the ECOM board disconnects from MP. Remain on: Abnormal Remain on: Running Flash slowly: If the run light flashes simultaneously 2 HL2 Red Board failure with the alarm light, it means that the ECOM board disconnects from MP. Other abnormal cases Remain on: When the light flashes simultaneously with the run light, it notifies of clock loss and other abnormal cases Unlock 3 SW1 Switch button reset switch Press this button to trigger the board for reset. Work mode

Page 84 of 106

Maintenance Manual of ZXG10-BSC(V2)

6.

COMMLAPDBoard Running Information

There are 2 indicator lights and 1 switch on the COMM (LAPD) board as Table 3-6 shows:
Table 3-6 COMMLAPDIndicator Light Names and Their Meanings Position Name Descriptio n Green Meanings Work mode Flash slowly: Running Flash simultaneously with the alarm light: The board errs, e.g. clock loss. Remain on, remain out: Abnormal Remain on: Running Flash slowly: This board fails to communicate with MP. Flash slowly and simultaneously with the running light: The board errs, e.g. clock loss. Press this button to trigger the board for reset.

HL1

Run status:

HL2

Red

Board failure Unlock button reset switch

SW1

Switch

7.

ECOM (LAPD/MPPP/MPMP) Board Running Information


There are 2 indicator lights and 1switch on the ECOM LAPD/MPPP/MPMP board as Table 3-7 shows:

Table3-7
Position Name

ECOMLAPD/MPPP/MPMPIndicator Light Names and Their Meanings

Description

Meanings

Work mode Flash slowly: Running Flash simultaneously with the alarm light: The ECOM board fails to communicate with MP.

HL1

Green

Run status:

Remain on: Abnormal Remain on together with the alarm light: Clock loss. Remain on: Abnormal Remain on: Normal. Flash slowly and simultaneously with the

HL2

Red

Board failure

running light: The ECOM board fails to communicate with MP. Remain on and simultaneously with the running light: Clock loss.

SW1 3

Switch

Unlock button reset switch

Press this button to trigger the board for reset.

Page 85 of 106

Maintenance Manual of ZXG10-BSC(V2)

8.

PEPD (MON) Running Information

There are 2 indicator lights and 1 switch on the PEPDMON board as Table 3-8 shows:
Table 3-8 PEPDMONIndicator Light Names and Their Meanings Position 1 Name HL1 Descripti on Green Meanings Run status: Work mode Flash slowly: Running Flash fast: Sensor warm-up Remain on, remain out: Abnormal Remain on: Running On: Board failure, e.g. dual-port RAM check error Press this button to trigger the board for reset.

2 3

HL2 SW1

Red Switch

Board failure Unlock button reset switch

9.

PCOM Board Running Information

There are 6 indicator lights and 1 switch on the PCOM board as Table 3-9 shows:
Table 3-9 PCOM Indicator Light Names and Their Meanings Pos Name Des. Meanings Work mode Flash slowly: Running Flash simultaneously with the alarm light: disconnect from MP. Remain on, remain out: Abnormal

HL1

Green

Run status:

HL2

Red

Board failure

HL3

Green

Dial-MODEM transmit data Dial-MODEM receive data Baseband MODEM transmit data Baseband MODEM receives data Unlock button reset switch

HL4

Green

HL5

Green

HL6

Green

SW1

Switch

Remain on: Running Flash slowly and simultaneously with the running light: Disconnect from MP. Remain on: Hardware clock loss or other hardware failures Remain on: PCOM transmits data to dial-MODEM Remain on: PCOM doesnt transmit data to dial-MODEM Remain on: PCOM receives data from dial-MODEM Remain on: PCOM doesnt receive data from dial-MODEM Remain on: PCOM transmits data to baseband-MODEM Remain on: PCOM doesnt transmit data to baseband-MODEM Remain on: PCOM receives data to baseband-MODEM Remain on: PCOM doesnt receive data to baseband-MODEM Press this button to trigger the board for reset.

Page 86 of 106

Maintenance Manual of ZXG10-BSC(V2)

2.9.2

Board Running Information on Network Switching Layer 1. BOSN Board Running Information

There are 4 indicator lights and 2 switches on the BOSN board as Table 3-10 shows:
Table 3-10 BOSN Indicator Light Names and Their Meanings Position 1 Name HL1 Description Green Meanings Run status: Work mode Flash slowly: Running Flash fast: Data load synchronization Remain on, remain out: Abnormal Remain on: Running Flash slowly: This board fails to 2 HL2 Red Board failure communicate with the previous level. If it is still disabled within a certain amount of time, reset it. On: The board errs, e.g. clock loss. 3 4 5 6 HL3 HL4 SW1 SW2 Green Green Switch Switch The board is in active status The board is in standby status Unlock Unlock button button handover switch reset switch Remain on: The light remains on if the board is in active status. Remain on: The light remains on if the board is in standby status. Press this switch to changeover between active and standby Press this button to trigger the board for reset.

Page 87 of 106

Maintenance Manual of ZXG10-BSC(V2)

2.

DSNI/COMIBoard Running Information

There are 4 indicator lights and 2 switches on the DSNI/COMI board as Table 3-11 shows:
Table 3-11 DSNI/COMI Indicator Light Names and Their Meanings Position Name Descripti on Meanings Work mode Flash slowly: Running 1 HL1 Green Run status: Flash fast: This board fails to communicate with MP. Remain on, remain out: Abnormal Remain on: Running Flash slowly: This board fails to 2 HL2 Red Board failure communicate with the previous level. If the board is still disabled ,reset it. On: The board errs, e.g. clock loss. 3 4 5 6 HL3 HL4 SW1 SW2 Green Green Switch Switch The The board board is is in in Remain on: The light remains on if the board is in active status. Remain on: The light remains on if the board is in standby status. Press this switch to changeover between active and standby Press this button to trigger the board for reset. active status standby status Unlock button handover switch Unlock button reset switch

Page 88 of 106

Maintenance Manual of ZXG10-BSC(V2)

3.

Running Information of CKI Board

There are 11 indicator lights and 3 switches on the CKI board as Table 3-12 shows:
Table 3-12 DSNI/COMI Indicator Light Names and Their Meanings Position 1 2 3 4 5 6 7 8 9 10 Name HL1 HL2 HL3 HL4 HL5 HL6 HL7 HL8 HL9 HL10 Description Green Red Green Green Green Green Green Green Green Green Meanings Run status: Board failure 8KHz clock reference 2MHz clock reference 5MHz clock reference 2Mb clock reference Work mode Remain on: Running Flash fast: Abnormal communication with SYCK board. Remain on: Running On: Board failure On: 8K clock available Out: 8K clock reference unavailable On: 2M clock reference unavailable Out: 2M clock reference unavailable On: 2M clock reference unavailable Out: 5M clock reference unavailable On: 2Mb clock reference unavailable Out: 2Mb clock reference unavailable Using binary system, the four lights show the selected reference from the 16 ones, from top to bottom and from high to low. If the light is on, it is 1; if the light is out, it is 0. 03E8K 03 472MHz 03 8115MHz 03 12152MBT 03 On: Indicate that manual selection of clock reference is enabled. Out: Indicate that manual selection of clock reference is disabled. Reference selection button; if you press this button continuously, you can orderly select 16 references. Press this button to enable the CKI to be in manual enable and disable status by turns. Press this button to trigger the board for reset.

Reference selection indication

11

HL11

Green

Manual indication Manual selection: Manual enable Unlock button reset switch

12 13 14

SW1 SW2 SW3

Switch Switch Switch

Page 89 of 106

Maintenance Manual of ZXG10-BSC(V2)

4.

SYCK Board Running Information

There are 12 indicator lights and 4 switches on the SYCK board as Table 3-13 shows:
Table 3-13 SYCK Indicator Light Names and Their Meanings Position 1 2 3 4 5 6 7 8 Name HL1 HL2 HL3 HL4 HL5 HL6 HL7 HL8 Description Green Red Green Green Green Green Green Green Meanings Run status: Board failure The board is in active status The board is in standby status Fast capture status Tracing status Holding status Random run status Work mode Remain on: Running Out: Running On: Board failure On: The board is in active status Out: The board is in standby status On: The board is in standby status Out: The board is in active status On: The board is in fast capture status Out: The board is not in fast capture status On: The board is in tracing status Out: The board is not in tracing status On: The board is in holding status Out: The board is not in holding status On: The board runs in random status On: The board runs in none-random status Three indicator lights from (HL9 HL1A form a 3-bit binary coding. HL9 is the highest bit. HL11 is the lowest bit. 1 indicates the light is on while 0 indicate the light is out. Their meanings are specified as below: HL9 HL11 is 000 Clock has no reference. HL9 HL11 is: 001 100 are selected clock references of this board. This board has four lines of clock references to be selected. HL9 HL11 is 101: Choose the clock reference sent from CKI

HL9

Green

10

HL10

Green

Select reference

11

HL11

Green

Page 90 of 106

Maintenance Manual of ZXG10-BSC(V2)


Continued table 3-13 Position 12 Name HL12 Description Green Meanings Manual enable Unlock button select switch Unlock button enable switch Unlock button handover switch Unlock button reset switch Work mode On: Indicate that manual selection of clock reference is enabled. Out: Indicate that manual selection of clock reference is disabled. Press this button to orderly select the clock reference Press this switch. Manually select the clock reference to enable indicator light (on or out). The manual selection of this switch becomes valid only when this light is on. Press this switch to changeover between active and standby Press this button to trigger the board for reset.

13

SW1

Switch

14

SW2

Switch

15 16

SW3 SW4

Switch Switch

2.9.3

TC Unit Panel Indicator Information 1. DRT/EDRT Board Run Information

There are 3 indicator lights and 1 switch on the DRT/EDRT board as Table 3-14 shows:
Table 3-14 DRT/EDRT Indicator Light Names and Their Meanings Position 1 Name HL1 Description Green Meanings Run status: Work mode Flash slowly: Running Flash fast: This board fails to communicate with MP. Remain on, remain out: Abnormal Out: Running Flash slowly: This board fails to communicate with the previous level. If the board is still disabled, reset it. On: The board errs, e.g. clock loss. On: None of the DSPs has speech channels being processed. Out: Speech- channels are in processing status. Press this button to trigger the board for reset.

HL2

Red

Board failure

3 4

HL3 SW1

Green Switch

Idle status Unlock button reset switch

Page 91 of 106

Maintenance Manual of ZXG10-BSC(V2)

2.

TIC/DTI Board Running Information

There are 6 indicator lights and 1 switch on the TIC/DTI board as Table 3-15 shows:
Table 3-15 TIC/DTI Indicator Light Names and Their Meanings Position Name Descriptio n Meanings Work mode Flash slowly: Running 1 HL1 Green Run status: Flash fast: This board fails to communicate with MP. Remain on, remain out: Abnormal Out: Running Flash 2 HL2 Red Board failure slowly: This board fails to communicate with the previous level. If the board is still disabled ,reset it. On: The board errs, e.g. clock loss. Flash fast: Running 3 HL3 Green DT1 Remain on: Alarms Out: E1 interface is not initiated yet. Flash fast: Running 4 HL4 Green DT2 Remain on: Alarms Out: E1 interface is not initiated yet. Flash fast: Running 5 HL5 Green DT3 Remain on: Alarms Out: E1 interface is not initiated yet. Flash fast: Running 6 HL6 SW1 Green Switch DT4 Unlock reset switch button Remain on: Alarms Out: E1 interface is not initiated yet. 7 Press this button to trigger the board for reset.

Page 92 of 106

Maintenance Manual of ZXG10-BSC(V2)

3.

GPP Board Running Information

There are 4 indicator lights and 2 switches on the GPP board as Table 3-16 shows:
Table 3-16 GPP Indicator Light Names and Their Meanings Position Nam e Description Meanings Work mode Flash slowly: Running Flash fast: If it flashes slowly with the red light, it means HDLC communication ceases, otherwise, it means it is extracting data from the database. Remain on, remain out: Abnormal Out: Running 2 HL2 Red Board failure Flash slowly: HDLC communication failure On: The board errs, e.g. clock loss. The board is 3 HL3 Green in active status The board is 4 HL4 Green in standby status Unlock 5 SW1 Switch button handover switch Unlock 6 SW2 Switch button reset switch Press this button to trigger the board for reset. On: The light remains on if the board is in active status. Out: The light remains on if the board is in standby status. On: The light remains on if the board is in standby status. Out: The light remains on if the board is in active status. Press this switch to changeover between active and standby

HL1

Green

Run status

2.9.4

Page 93 of 106

Maintenance Manual of ZXG10-BSC(V2)

2.9.5

GPRSPP Board Running Information 1. PUC Board Running Information

There are 4 indicator lights and 2 switches on the PUC board as Table 3-17 shows:

Table 3-17 PUC Indicator Light Names and Their Meanings Position Name Description Meanings Work mode HL1 flashes slowly, HL2 out Running HL1 flashes fast, HL2 out Wait for 1 HL1 Green Run status: data synchronization HL1 and HL2 slowly flash at the same time: Program loading Out: Running 2 HL2 Red Board failure Flash fast: This board disconnects with the previous HDLC. Remain on: Clock loss On: The light remains on if the board is 3 HL3 Green The board is in active status in active status. Out: The light remains on if the board is in standby status. On: The light remains on if the board is 4 HL4 Green The board is in standby status Unlock Unlock button button in standby status. Out: The light remains on if the board is in active status. 5 6 SW1 SW2 Switch Switch Press this switch to changeover handover switch reset switch between active and standby Press this button to trigger the board for reset.

Page 94 of 106

Maintenance Manual of ZXG10-BSC(V2)

2.

BRP Board Running Information

There are 4 indicator lights and 1 switch on the BRP board as Table 3-18 shows:
Table 3-18 BRP Indicator Light Names and Their Meanings Pos Name Description Meanings Work mode HL1 flashes slowly, HL2 out Running HL1 flashes fast, HL2 out Wait for data 1 HL1 Green Run status synchronization HL1 and HL2 slowly flashes at the same time: Program loading Out: Running 2 HL2 Red Board failure Flash fast: This board disconnects with the previous HDLC. Remain on: Clock loss 3 4 HL3 HL4 Green Green DSP1 DSP2 Unlock 5 SW1 Switch button reset switch Flash slowly: ESP1 program is in execution Other statuses: Abnormal Flash slowly: ESP2 program is in execution Other statuses: Abnormal Press this button to trigger the board for reset.

Page 95 of 106

Maintenance Manual of ZXG10-BSC(V2)

3.

FRP Board Running Information

There are 4 indicator lights and 1 switch on the FRP board as Table 3-19 shows:
Table 3-19 FRP Indicator Light Names and Their Meanings Pos. Name Description Meanings Work mode HL1 flashes slowly, HL2 out Running HL1 flashes fast, HL2 out Wait for data 1 HL1 Green Run status: synchronization HL1 and HL2 slowly flashes at the same time: Program loading Out: Running 2 HL2 Red Board failure Flash fast: This board disconnects with the previous HDLC. Remain on: Clock loss Flash 3 HL3 Green DSP1 slowly: ESP1 program is in execution Other statuses: Abnormal Flash 4 HL4 Green DSP2 Unlock button reset switch slowly: ESP2 program is in execution Other statuses: Abnormal 5 SW1 Switch Press this button to trigger the board for reset.

Page 96 of 106

Maintenance Manual of ZXG10-BSC(V2)

4.

GIPP Board Running Information

There are 4 indicator lights and 2 switches on the GIPP board as Table 3-20 shows:
Table 3-20 GIPP Indicator Light Names and Their Meanings Position Name Description Meanings Work mode HL1 flashes slowly, HL2 out: Running HL1 flashes fast, HL2 out Wait for data 1 HL1 Green Run status: synchronization HL1 and HL2 slowly flash at the same time: Program loading Out: Running 2 HL2 Red Board failure Flash fast: This board disconnects with the previous HDLC. Remain on: Clock loss On: The light remains on if the board is in 3 HL3 Green The board is in active status active status. Out: The light remains on if the board is in standby status. On: The light remains on if the board is in 4 HL4 Green The board is in standby status Unlock Unlock button button standby status. Out: The light remains on if the board is in active status. 5 6 SW1 SW2 Switch Switch Press this switch to changeover between active and standby Press this button to trigger the board for reset. handover switch reset switch

2.9.6

POWB Board Running Information 1. POWB Board Running Information There are 2 indicator lights on the POWB board as Table 3-21 shows:

Page 97 of 106

Maintenance Manual of ZXG10-BSC(V2)

Table 3-21 POWB Indicator Light Names and Their Meanings


Position 1 2 Name HL1 HL2 Descriptio n Green Red Meanings Run status Board failure On: Running Out: Board failure On: Board failure Out: Running Work mode

2. POWP Rack Distributor Running Information

The POWP rack distributor has 4 indicator lights and 1 switch, I antistatic wrist strap, with meanings as Table 3-22 shows:
Table 3-22 POWP Indicator Light Names and Their Meanings Position 1 2 Name HL1 HL2 Description Green Green Meanings Fan Power Power 3 HL3 Red undervoltage indication Power 4 HL4 Red overvoltage indication 5 SW1 Switch Power switch Power switch, turn upwards to power on; turn downwards to power down. On: Input overvoltage Out: Normal input voltage power supply On: Running On: Running On: Input undervoltage Out: Normal input voltage indicator light indicator light Work mode

Note: POWP indicator lights and switches are orderly arrayed as 1, 2, 3, ,5.

Page 98 of 106

Maintenance Manual of ZXG10-BSC(V2)

2.9.7

Other Boards Running Information


1. SMB Board running information

There are 5 indicator lights and 1 switch on the SMB board as Table 3-23 shows:
Table 3-23 SMB Indicator Light Names and Their Meanings Position 1 Name HL1 Description Green Meanings Run status Work mode Flash slowly: Running Remain on, remain out: Abnormal Out: Running Flash slowly: This board fails to communicate 2 HL2 Red Board failure with the previous level. If the board is still disabled, reset it. On: The board errs, e.g. clock loss. Flash fast: Running 3 HL3 Green E1-1 On: E1 alarm Out: E1 port is not configured yet. Flash fast: Running 4 HL4 Green E1-2 On: E1 alarm Out: E1 port is not configured yet. Flash fast: Running 5 HL5 SW1 Green Switch E1-3 Unlock button reset switch On: E1 alarm Out: E1 port is not configured yet. 6 Press this button to trigger the board for reset.

2.

running information of each board during version loading

During the version loading, each board has 2 indicator lights: HL1 and HL2, with meanings shown in Table 3-24.
Table 3-24 Version loading Indicator Lights and Their Meanings Position 1 2 Nam e HL1 HL2 Description Green Red Meanings Run status Board failure Work mode Flash slowly: Ready for loading Flash fast: Loading is in process. Remain on, remain out: Abnormal Flash fast: Running in BOOT. Merely targeting the boards demanding for version loading, e.g. BOSN, DRT, EDRT, GPP, ECOM, etc.

Page 99 of 106

Maintenance Manual of ZXG10-BSC(V2)

Appendix A Replacement of Boards and Components


A.1 Overview
In daily maintenance operation, replacing faulty boards is a common and also an important maintenance mode. When replacing boards, the maintenance personnel are recommended to contact relevant technical professionals or the local office personnel of ZTE Corporation so as to get technical instructions. In the process of replacing boards, it is necessary to follow rules as follows: 1. In the usual time, the unopened spare parts should be kept in antistatic packages (Drier bags are preferred inside the bag) classified and saved in cartons. Types and models should be labeled clearly on the antistatic bags or cartons for the convenience of identification. 2. Wear antistatic wrist straps before plugging/unplugging boards. When holding boards in hand, be cautious enough to keep away from circuits, components, connection slots, etc. Never overexert yourself when you plug/unplug boards so as to prevent from distorting boards or the pins and slots on the backplane. 3. The removed faulty boards should be labeled with fault causes before put into the antistatic bags and should be kept in classification. 4. After the faulty boards are removed, if no spare parts are available at the moment, put an idle dam board onto the vacant position in order to keep clear of dust or play an ornate role. 5. Make sure to mount the module into its position.

6. Hot plug/unplug operation is strictly prohibited when replacing power boards or MP.

A.2
1.

Procedures of Replacing Public Boards


Preparations before replacement
Page 100 of 106

Maintenance Manual of ZXG10-BSC(V2)

1)

By observing and analyzing errors, locate the faulty boards and replace them. Make sure that spare parts are functionally intact and their models comply with the faulty boards. A sufficient provision of antistatic bags, drier bags and assorted cartons is available for convenience of labeling faulty components. Replacement procedures Wear antistatic wrist straps. When using the standby board to replace the active board, perform the active/standby changeover first so as to enable the standby board to be in active status beforehand. Using one hand to forcefully turn the fastener on the faulty board outwards and downwards; when the board is removed from the insertion slot and flip outwards, you use the other hand to hold the lower edge of the board and then gently pull the board out from its slot. In the process of this operation, you should try your best to avoid contacting the parts and circuits on the board Put the removed faulty boards into the antistatic bags with drier bags and label them clearly according to their models, attributed slots, program versions and words fault. Put the faulty boards in the cartons in category and label them clearly on the cover of the cartons so as not to confuse them next time. First aim at the slot labeled on the insertion box in line with the spare board name, then use the thumb to press the fastener on the circuit board and push the circuit into the slot with average force until the fastener locks it up. This shows the circuit board has reached its position. If the active board is to be replaced, perform another active/standby changeover after the replacement is over, thus enabling the new board to run in active status. Confirmation after replacement
Page 101 of 106

2)

3)

2.
1)

2)

3)

4)

5)

6)

3.

Maintenance Manual of ZXG10-BSC(V2)

When the circuit board is freshly inserted, there will be a self-test process lasting for some time. If the self-test succeeds, the indicator lights will be in normal status; if services operation recovers, it becomes a symbol of replacement success. For more information on how to distinguish the display status of indicator lights, read Chapter 3 in this manual. If the self-test fails in that the self-test proceeds continuously or indicates abnormality and the related unit has not recovered its services, this shows the replacement fails. Check and confirm whether the spare board is damaged or whether the fault is on other boards instead of on this one. Locate the fault by observing the alarm of fore/background.

A.3

Replacement of Other Components


In most cases, the components here refer to the whole layer shelf or the backplane. The office party and the related technical personnel should acknowledge the replacement operation beforehand. 1. Preparations before replacement Preparations to be made are the same as those before the replacement of public boards. Read A.2 for more details. 2. 1) 2) Procedures of replacing shelves and backplanes Wear wrist straps and turn off power supply system. Write down the specific boards and their corresponding slots and remove all the boards at this layer. Write down the slots and positions where cables are located, remove all the cables connected at the backplane, including the 38 cable and the 6-chip POWP cables on both sides. Remove the front door from t he rack and be careful to put it down lightly. Loosen the 4 screws on the shelf of this layer by starting from the front of the shelf. Pull out the shelf out from the front. Remove the backplane of the this layer after unscrewing it.

3)

4)

5)

6)

Page 102 of 106

Maintenance Manual of ZXG10-BSC(V2)

7)

Mount the new backplane onto the idle shelf (or install the backplane onto the new shelf). Make sure not to reverse the top/bottom directions of the backplane. Exactly in the same manner as the removed backplane, install the short circuit chip on the left and right sides of the new backplane. If the 38 cable lock chip is unavailable on the 96-core socket of the new backplane, install the cable lock chip onto it in exactly the same manner as is with the old backpane. Mount the shelf with new backplane onto the rack. Put back the front door of the rack. Based on the previous records, connect the power supply lines to the corresponding cables on the backplane. Be careful with the two (left/right) directions of the 38 cable. Merely the left or the right of the two directions can be locked if inserted by a lock chip, so does the 6-core power supply cable. Only one of its directions (left and right) can be inserted. If it fails, you try the other direction. Insert each board corresponding to the recorded slots. In the process of this operation, you should try your best to avoid contacting the parts and circuits on the board Be sure the cable connections and board slots are inerrable. Warning: MP s power supply is 48V. Other boards will be burnt if inserted to the MP slot.

8)

9) 10) 11)

12)

13)

14) 3

Power on the rack and initiate the system. Confirmation after replacement

There will be a self-test process lasting for some time before the system powers on after the replacement, MP initiation, board version loading and version running takes place respectively. If the self-test succeeds, the indicator lights will be in normal status. If services operation recovers, it symbolizes the replacement success. For more information on how to distinguish the display status of indicator lights, read Chapter 3 in this manual. If the self-test fails in that the self-test proceeds continuously or
Page 103 of 106

Maintenance Manual of ZXG10-BSC(V2)

indicates abnormality and the related unit has not recovered its services, this shows the replacement fails. Check and confirm whether the spare board is damaged or whether the fault is on other boards instead of on this one. Locate the fault by observing the alarm of the fore/background.

Page 104 of 106

Maintenance Manual of ZXG10-BSC(V2)

Appendix B Abbreviations
Abbreviations AIPP AIU BATC BBIU BCTL BIE BIPP BIU BNET BOSN BRP BSC BSMU BSS BTS CKI COMI COMM DRT DSNI DSP DTI EDRT EGSM FRP FSMU FSPP GIPP GPP GPRS GSM HW LAPD LED LMT MON Table Continued Full Names in English A Interface Environmental Processor A Interface Unit Backplane of A interface and TransCoder Backplane of Abis Interface Unit Backplane of ConTroL Base station Interface Equipment aBis Interface Environmental Processor aBis Interface Unit Backplane of NET Bit-Oriented Switching Network BSSGP RLC/MAC Protocol processor Base Station Controller Backplane of SubMultiplexing Unit Base Station Subsystem Base Transceiver Station ClocK Interface board COMmunication Interface board COMMunication board Dual-Rate Transcoder Digital Switch Network Interface Digital Signal Processor Digital Trunk Interface Enhanced DRT Enhanced Global System for Mobile communication Frame Relay Protocol Processor Far SubMultiplexing Unit Far Submultiplexing Environmental Processor Gb Interface Environmental Processor General Environmental Processor General Packet Radio Service Global System for Mobile communication HighWay Link Access Protocol on the D channel Low Emitting Diode Local Maintain Terminal MONitor board

Page 105 of 106

Maintenance Manual of ZXG10-BSC(V2)


Abbreviations MPMP MPPP MS MSC MSS MTP NSMU NSPP NSU PCB PCM PCU PDCH PEPD POWB POWP PUC PSTN RMU RXLE RXQUA SCCP SCM SCU SM SMB SMEM SMPP SMU SUBPP SYCK TC TCP TCPP TCU TIC Full Name in English MP To MP MP To PP Mobile Station Mobile Switching Center Mobile Switch System Message Transfer Protocol Near SubMultiplexing Unit Near Submultiplexing Environmental Processor Net Switching Unit Printed Circuit Board Pulse Code Modulation Packet Control Unit Packet Data CHannel Environmental Environment &Power Detecting board POWer B POWer P Packet Unit Controller Public Switching Telephone Network Radio Manage Unit Rx Level Rx QUAlity Signaling Connection Control Part System Control Module System Control Unit SubMultiplexing Subrate Multiplexing to Bts Share MEMory Subchannel Multiplexing Environmental Processor Subchannel Multiplexing Unit SUB Environmental Processor SYnchronous ClocK board Trans Coder Transfer Control Protocol TransCoder unit Environmental Processor TransCoder Unit Trunk Interface Circuit

Page 106 of 106