Overcurrent Coordination Basics Transformer

The information presented in this application guide is for review, approval, interpretation and application by a registered professional engineer only. SKM disclaims any responsibility and liability resulting from the use and interpretation of this information. Reproduction of this material is permitted provided proper acknowledgement is given to SKM Systems Analysis Inc Purpose The purpose of this guide is to provide a basic overcurrent protection philosophy for transformers. Transformer Overcurrent Protection Time-current curve (TCC) landmarks (figure 1) All landmarks are based on the nominal kVA rating of the transformer Full load amps (FLA) located in the upper decade Thermal damage curve located in the upper 3 decades Mechanical damage curve located in the middle decade Inrush points defined @ 12 x FLA and 0.1 seconds, and 25 x FLA and 0.01 seconds TCC regions (figure 2) Equipment operating region located at and to the left of the FLA and inrush points Equipment damage region located to the right and above the damage curves Protective device operating region located between the equipment operating and damage regions Suggested overcurrent protection (figure 3) Set protection above the full load amps and inrush points Set protection below the damage curves Comments If current penetrates the limits of the thermal damage curve, insulation damage may occur. If current penetrates the limits of the mechanical damage curve, cumulative mechanical damage may occur.

Fig. 1 Transformer TCC landmarks

Fig. 2 Transformer TCC regions

Fig. 3 Transformer overcurrent protection References Other Application Guides offered by SKM Systems Analysis at www.skm.com Electrical Transmission and Distribution Reference Book, ABB Power T&D Company, Raleigh, North Carolina, 1997 Protective Relaying Theory and Applications, 2nd Edition, Marcel Dekker, New York, 2004 The latest revision of: IEEE Std 242, IEEE Recommended Practice for Protection and Coordination of Industrial and Commercial Power Systems (IEEE Buff Book) IEEE Std C37.91, IEEE Guide for Protective Relay Applications to Power Transformers IEEE Std C57.12.59, IEEE Guide for Dry-Type Transformer Through-Fault-Current Duration IEEE Std C57.109, IEEE Guide for Liquid-Immersed Transformer Through-Fault-Current Duration

back to Application guides

products

support

contact us

distributors

Copyright SKM 2010

You might also like