You are on page 1of 72

PRESENTATION

Ermatic®

GENERAL
the adaptable solution
Ermatic® is a comprehensive and highly speci-
fied range of access covers for diverse under-
ground services
 Sewerage: inspection pits for sludge chambers,
access shafts for large items of plants.
 Telecommunications: cable jointing chambers.
 Electricity: lighting, signals, transformer pits,
cable joint boxes.
 Potable water, gas, district heating, valve
chambers, manifold chambers and meter
chambers

In the following environments:


 Airports and ports,
 Railways,
 Power stations,
 Water treatment and purification plants,
Modular construction  Manufacturing plants,
 Industries,
The use of modular
elements gives a vast  Exhibition centres and leisure parks.
range of sizes
Ermatic® assures protection against damage,
debris or aggressive chemicals, and allows
1/2/3 – part unit
designers to conceal underground
rame elements (side frames and end plates) are assembled services, maximising productive use of the
using bolts and aluminium joints to provide linear openings for unobstructed surface.
even the longest ducts.

Duct cover Stability and Sealing


The horizontal and vertical faces of the cover and frame are
machined to give metal-to-metal contact between the seating faces,
within a tolerance of 0.2 mm.

 Stability: when correctly installed, Ermatic® products are


Above clear opening non-rocking, silent under traffic and prevent the ingress of dust
spans of 1200 mm, Ermatic® and debris.
units employ removablebeams
supported in boxes which are fixed to the frames. This per-  Sealing: the addition of a film of grease to the machined
mits the construction of units to suit the largest openings. contact faces of the cover and frame renders the Ermatic®
cover watertight under normal rainwater conditions.

Machined
contact
faces

Multiple unit
with
removable
beams

1
1/2/3 COUVERCLES

Guayaquil - Ecuador
Ermatic®

PRESENTATION
GENERAL
the correct solution
Environment, security, ergonomics, the
Ermatic® range benefits from the advanced
technology of the Norinco Group:
 appearance of the project is enhanced: the
covers can be recessed to receive a similar
material to the surround,
 rapid and easy access for maintenance and
TYPES OF SURFACE FINISH AVAILABLE
development of the network,
 security reinforced by the strength and
Designed for a wide range of applications, The stability of the covers.
Ermatic® range offers a choice of covers to suit every
specification of performance and/or appearance.

HANDLING WITH EASE


Solid top cover with
uniform anti-slip surface Handling with ease: Covers slide in and
out of the frame along greased, machined
This cover offers unequaled seatings, requiring no vertical lift.
performance whilst being lighter Ermatic® key: ergonomically assists with
than recessed covers of a safety. Further reduces the effort required
comparable size when filled with to remove and replace covers.
concrete. Installation costs are reduced and the performance is UNIVERSAL KEYWAYS
not influenced by the quality of the concrete infill.  For use with many different types of
common lifting keys.
 Fitted with polyethylene
Cover recessed for concrete infill blanking plugs to
prevent the entry
In classes B 125 and C 250, of debris or
the ribs are positioned below the concrete.
surface of the cover to permit the RIBS EXTEND BELOW THE
installation of thin paving.This type of UNDERSIDE OF THE COVER
cover is particularly
suited to large openings where To protect the machined
aesthetic considerations are a priority. seatings, the reinforcing webs
The concrete infill is undertaken in are deeper than the cover. This also prevents any greased
accordance with the requirements of EN124: 1994 and with Norinco’s surfaces coming into contact with the floor (except for some
specifications detailed in this brochure (see page 84) B 125 recessed covers). (see handling page 85)

LOCKING OF THE COVERS

Other types: In order to ensure an easier and more optimised installation


of our ERMATIC® systems, it has been
Covers recessed for small decided to supply all
element paving for pedestrian the products in D400
areas (see page 19) systematically locked.
For E600 and F900
productslocking
is recommended for
the same reasons.
ADJUSTING BOLTS
Cover with central removable
plug (see page 21and 33) .
In order to facilitate the levelling
of ERMATIC® systems, adjusting
bolts are supplied with the
Painting products. These bolts will allow,
Covers and frames: painted with water soluble black paint except if necessary, to adjust the height
for machined surfaces and surfaces in contact with concrete. of the system to the final level
Where products are delivered in a dismantled condition, all and correct any possible defects
machined surfaces are coated with a protective film. of the civil work.

3
Dublin - Irland
DOSSIER TECHNIQUE MULTIPLES À POUTRELLES CANIVEAUX 1/2/3 COUVERCLES
Ermatic®

PRESENTATION
GENERAL
for every application
worldwide
NORINCO – A WORLDWIDE ORGANISATION

The power of the production facility, the capacity


of our innovation, the research and development,
and the strenght of the commercial organisation
makes Norinco a worldwide name in the field of
access covers and gratings, for diverse under-
ground networks.

Norinco is represented around the world by its subsidiaries:

 Norfond and Norinco France in France


 Norinco Do Brasil in Brasil
 Norinco Italia in Italy
 Norinco Iberica in Spain
 Norinco Deutschland in Germany Norinco also has other ranges of innovative
 Norinco UK in Great Britain
 Norinco Singapore Rep. Office in Singapore products for all applications.
 Norlong in China TELECOMMUNICATIONS AND CABLE NETWORKS
Norinco's distribution network is supplemented by a num- Access covers for
ber of independant distributors throughout the world, cove- telecommunications chambers
ring the main technical and industrial areas.

Ermatic® - AN INTERNATIONAL REFERENCE


INSPECTION COVERS FOR
In many diverse applications, an impressive list of international
DIVERSE NETWORKS
references proves the performance, reliability and quality of the
Ermatic® range. The following is a selection of prestigious TI 9S 100 100AVH11
international projects where Ermatic® has been used Access covers
extensively. for inspection

 Airports: Manchester Runway II, BAA Heathrow,


East Midlands (UK), Kaitak (Hong-Kong), Changi (Singapore)
Madrid Barajas (Spain), Roissy CDG (France) CA 1040FVLV
Dublin (Ireland), Frankfurt, Stuttgart, Munich (Germany),
Athens (Greece), Dubaï International (UAE), Linate Milan Milan MAXIMO
Malpensa, Catania, Genoa, Naple (Italy), Pierre Trudeau Gratings, gully tops
International Airport (Canada), Ezeiza ( Argentina), Miami and kerb outlets for drainage
International Airport (USA), Johannesburg International Airport
(South Africa), Sangster International Airport (Jamaica),
Warsaw International Airport (Poland) etc.. .
 Ports: Dubaï Dock (UAE), DML Devonport Royal Dockyard, SPECIFIC PRODUCT DEVELOPMENT
Portsmouth Naval Base HMS Warrior Portsmouth (UK),
Dunkerque, Rouen (France), Bremenhaven, Kiel (Germany), Norinco's commercial and technical departments work together
Trieste (Italy), Valencia ( Spain) etc.. . to consider specific product development studies in close
 Industries: Ciba Geigy, Renault, Peugeot (France), collaboration with clients. If you have any such project where the
Audi, BMW, Mercedes Benz, Siemens (Germany), ideal Ermatic® cover is not depicted in this catalogue, please
Hewlett Packard, Pfizer Chemical (Ireland), contact us. (See p. 86)
LG Semi conductor plant Newport, Hull UWWTD, Royal Mail
Distribution Centre Sheffield, Manchester Convention (UK),
Bayer (Belgium).
 Other major projects: Channel tunnel, Disneyland Paris,
TGV train stations, Bilbao Exhibition Centre, etc.. .

5
Toulose Blagnac Airport - France
Ermatic®

PRESENTATION
GENERAL
Quality assurance at
every stage of manufacture
A fully European production Expertise in design
 As per ISO 9001: 2000

 As per the exact requirements of clients.

 Following EN124: 1994 standard and others stan-


dards.

Expertise in production

 Material: Ductile (or SG) cast iron.


Products are 100% ductile iron, recyclables à l’infini
NORFOND  Total integration of every manufacturing process.
PARIS
 Control manufacturing process and final assessment.

Expertise in customer network


 Comprehensive commercial service.

 Rapid supply of documentation.

ISO 9001: 2000  Technical assistance:


At the design stage: from conception to installation,
experts are available to assist with the selection and prescrip-
ERMATIC® products are fully conceived and produ- tion of ideal products, including
ced in a European foundry . the provision of drawings of covers
and rebates for ducts and beamed
multiple covers.
During Installation: for PLAN

1/3
NORFOND

the correct installation of


PRODUKT ERMATICÆ ER5R199214VCHC Artikelnummer : 515075
"EM" Bedienungsschl¸ssel
Bestellung : 0 (2 Stk.)(nicht im Lieferumfang)

Beschreibung : ERMATICÆ D400 Fl‰chenabdeckung zur bauseitigen Betonf¸llung verriegelt CHC

Gewicht : 1503 Kg

÷ffnungsrichtung

large or complex covers,


600 600 600

the production centre can E


R
M
A
T
IC

DETA
ILS
E
R
M
A
T
IC
E
R
M
A
T
IC
600

3/3
A D G

h.

provide,upon request,
bindlic
unver
O e sind O O O O O
E
R
M ht, Grˆ{fl
. E
R
M E
R
M
A
T Gewic A
T A
T
en zuIC vorbehalten IC IC
- Angabungen .
- ƒnder Verbreitung
OND - Freie
NORF 75
600

5150
er : B E H
1990

lnumm
HC Artike
14VC
1992
ER5R
TICÆ vation

skilled technicians to assist


ERMA reser O O O O O O
heral
Perip E
R E
R E
R
M M M
UKT IA
TC IA
TC IA
TC
PROD

0
750

:
170

llung C F I
Beste shims
ing steel
Levell
ering
cover Shutt
20

and
bar
frame
n on 500-7 ng

with the installation process.


Sectio Grade Openi
63, Clear
/ EN15
70

1083 O O O O O O
to ISO
SG Iron
R
COVE
80

PRO
Bes DU
tell KT
ung
250 : NO
150

0 ERM RFO
2140 ND
ATI

ng ON BEAM ER5
ION R19
Openi
Clear SE SECT Fram
e 921
SVER 4VC
TRAN
HC
110 Art
ikel
num
me
r:
515
075 VER
MA
150

boxe flUN

After-sales service.
Wall


G
500

- Ang 2/3
250 - ƒnd abe
- Fre eru n zu
screw
nge Gew
ie Ver n icht
steel
Chc bre vorbeh , Grˆ
less Alle Grˆ{flenangaben in mm. itun
Stain 0 g. alten. {fle sind
L‰nge gesamt : 2350 IPE36 Rahmen und Deckel aus Guss
key Beam unv
Chc Breite gesamt : 2360
GS 500-7 gem‰{fl ISO 1083 erb
214 indl
0 ich.
er
wash :
Maflstab 1/ 20 Erstellt von : at Datum : 14/04/2006
- Angaben zu Gewicht, Grˆ{fle sind unverbindlich.
steel
less ing bolts
Stain NORFOND Levell Norinco Deutschland GmbH - ƒnderungen vorbehalten.
Dieses Dokument ist Eigentum von Norfond und darf nicht ohne
Einemstrafle 5 - Freie Erlaubnis
Verbreitung.
GROUPE NORINCO D-10787 Berlin weitergegeben oder vervielf‰ltigt werden.
www.norinco.fr Tel. +49-30-200 51-0 Fax +49-30-200 51-299
540

norinco@norinco-germany.com
360
er
wash
rene 450
Neop

boxes
and
beam
500

n on
l sectio
tudina
Longi
470
0

0
199

250

IPE36
E BEAM
VABL
REMO
170

540
170

nd und n.
Openi
ng von
Norfo igt werde
tum lf‰lt
Clear vervie
ist Eigen oder
ent

Norfond is certified by third parties for conformity to


06 ben
4/20 s Dokum weitergege
14/0 Diese
: bnis
Datum Erlau
ohne
nicht
darf 450
at
:
170 llt von d GmbH
Erste chlan 5 9
e
co Deutsstrafl 51-29
Norin Einem 87 Berlin 0-200
0

m
D-107 Fax +49-3
199

any.co
51-0 germ 685
0-200 rinco-

ISO 9001: 2000. This quality management is recogni-


OND +49-3norinco@no
NORF NCO Tel.
PE NORI o.fr
GROU norinc
www.
145
5

Alle
Grˆ
{fle
250

nan
Ma gab
en

sed as a reference for design, development, produc-


flst in mm
ab
: .
1/
NO 25
RFO
ND
GRO
UPE Ers
ww tell
w.n NORIN t von
orin :
co.f CO Norin
r co
Deuts at
Einem chlan
Tel. D-10787 strafl d
Fax +49-3 e 5 GmbH
Berlin Dat

tion, installation and after-sales service.


norin +49-3 0-200
co@n 0-200 51-0 um
orinc
o-ger 51-29 : 14/
many 9
.com 04/
200
6

nich Dieses
t ohn Dok
e Erla ument
ubn
is wei ist Eige
terg ntu
ege m von
ben Nor
ode
r ver fond und
viel dar
f‰ f
ltig
t wer
den
.

Products are made from 100% ductile iron:


manufacture from this material provides reliability and
strength. Ductile iron is produced by converting the
inherently brittle grey cast iron, by the addition of
magnesium before pouring. This gives a material with
high elasticity, particularly resistant to forces and shock.
(See p. 87)

7
Ermatic®
Cover and Frame
Conformity
EN124 Standard Ermatic® Range

 Determines the following characteristics of covers and frames:  All Ermatic® covers are designed to meet all the
requirements of the EN124 standard.
 Principles of construction: frame depth, depth of insertion,
seatings, surface condition etc.  All Ermatic® covers are manufactured from ductile iron accor-
ding to ISO 1083 and EN 1563.
 Material used for the manufacture of covers.
 All solid top covers and recessed B125/C250/D400/E600
covers are tested in the as-cast condition and meet all the test cri-
 Testing regime: test loads and permanent set limits teria of the EN124: 1994 standard. F900 recessed covers
attain resistance characteristics after filling with concrete, com-
plying with EN124 standards and the recommendations on page
84.

Loading and conformity certificates in accordance with the requi-


rements of EN124: 1994

The dimensions of removable beams in multiple units are


derived from the following French
specifications
Ermatic® B 125:......................Loading 500 daN/m2
Ermatic® C 250: ..............CCTG volume 61 - clause 2
Ermatic® D 400:..............CCTG volume 61 - clause 2
Ermatic® E 600/F 900:.....................ADP and STBA

 The design and manufacture of Ermatic® covers is undertaken


 Requires a quality system equivalent to ISO 9002. within one facility operating a quality system certified by third party
to ISO 9001 : 2000.

 Requires that products are clearly marked with the mark  The EN124 standard is limited to covers with a clear
of a certification body. opening dimension ≤1000 mm. Consequently, units above this
dimension, particularly those that utilise removable beams, are
outside the scope of EN124. However, some 1,2 and 3 part solid
top units, from which multiples are constructed, carry third party
certification to conform with the requirements of EN124 (please
consult us for further information).

Product characteristics are dependent upon correct installation in accordance with the recommendations on p. 78. Drawings,
photos, dimensions and weights are given as an indication without any contractual value. Our policy is one of continuous
product improvement, we reserve the right to modify product specifications without prior notice.

8
SELECTION GUIDE
Ermatic®
Loading classes and
their application
The EN124 standard introduced the idea of Recommended Ermatic®
groups and minimum class, depending on the place
of installation of access covers and frames.

GROUP 1 (class A 15 minimum)


Design load: 15 kN
Place of installation:
Areas which can only be used by
pedestrians and pedal cyclists.

GROUP 2 (class B125 minimum) ERMATIC® B125


Design load: 125 kN Place of installation:
Place of installation:
Footways, pedestrian areas and
Group 2 and lower. B125
comparable areas, car parks or car parking decks

GROUP 3 (class C250 minimum) ERMATIC® C250


Design load: 250 kN Place of installation:
Place of installation: Group 3 and lower including parking
For gully tops installed in the area of kerbside channels of
C250
areas for all types of road vehicles,
roads which when measured from the kerb edge, extend a forecourts and service areas.
maximum of 0.5 m into the carriageway and a maximum of
0.2 m into the footway.

GROUP 4 (class D400 minimum) ERMATIC® D400


Design load: 400 kN Place of installation:
Place of installation: Group 4 and lower.
Carriageways of roads (including pedestrian streets), hard
D400
shoulders and parking areas for all types of road vehicles

GROUP 5 (class E600 minimum) ERMATIC® E600


Design load: 600 kN Place of installation:
Place of installation: Group 5 and lower.
Areas imposing high wheel loads e.g. docks, aircraft E600
pavements.

GROUP 6 (class F900 minimum) ERMATIC® F900


Design load: 900 kN Place of installation:
Place of installation: Group 6 and lower.
Areas imposing particularly high wheel loads e.g. docks, F900
aircraft pavements.

The selection of the appropriate class is the responsibility of the designer. Where there is any doubt, the
stronger class should be selected.

9
To cover chambers with clear openings (a x b)
up to 3040 mm in lenght x 1 200 mm in width

1/2/3 - part covers


Introduction...........................................................P.12
Ermatic® B 125
• Recessed for concrete infill ........................................P.14
• With solid top anti-slip surface ...................................P.16
Ermatic® C 250
• Recessed for concrete infill.........................................P.18
• With solid top anti-slip surface ...................................P.20
X

1/2/3 COUVERCLES
Ermatic® D 400
• Recessed for concrete infill.........................................P.22
• With solid top anti-slip surface ...................................P.24
Ermatic® E 600
• Recessed for concrete infill.........................................P.26
a
• With solid top anti-slip surface ...................................P.28
n g:
Ermatic® F 900 e ni
• Recessed for concrete infill.........................................P.30 op
• With solid top anti-slip surface ...................................P.32
e ar
cl

m m
60
x 36
Ma m
m
40
30

CANIVEAUX
0

MULTIPLES À POUTRELLES
1
20
0
m
m

c
le
a
r
o
p
e
n
in
g
:
b
5
18

DOSSIER TECHNIQUE
0
m
m

(p
le
as
e
X nsu
co

10
lt
us
)
SELECTION GUIDE
Ermatic®
Selection guide
In order to select the ideal Ermatic® cover it is necessary
to consider:
• The required surface condition of the covers (P.3)
• Loading classes and their application (P.9)
and finally, the characteristics of the
chamber or duct to be covered.

To cover ducts with clear openings (b) lower than


1 200 mm

Duct covers
Introduction...........................................................P.34
Ermatic® B 125
• Recessed for concrete infill.........................................P.36
• With solid top anti-slip surface ....................................P.38
Ermatic® C 250
• Recessed for concrete infill.........................................P.40
• With solid top anti-slip surface ....................................P.42
Ermatic® D 400
• Recessed for concrete infill.........................................P.44
• With solid top anti-slip surface ....................................P.46
Ermatic® E 600
• Recessed for concrete infill.........................................P.48
• With solid top anti-slip surface ....................................P.50
Ermatic® F 900
• Recessed for concrete infill.........................................P.52
• With solid top anti-slip surface ....................................P.54

To cover large chambers with clear openings (a x b)


greater than 1 200 x 1 200 mm
clear opening up to 3 660 x 5180 mm.
(a x b) For sizes in excess of this, please consult us.

Multiple covers with removable beams


Introduction...........................................................P.56
Ermatic® B 125
• Recessed for concrete infill.........................................P.58
• With solid top anti-slip surface ....................................P.60
Ermatic® C 250
• Recessed for concrete infill.........................................P.62
• With solid top anti-slip surface ....................................P.64
Ermatic® D 400
• Recessed for concrete infill.........................................P.66
• With solid top anti-slip surface ....................................P.68
Ermatic® E 600
• Recessed for concrete infill.........................................P.70
• With solid top anti-slip surface ....................................P.72
Ermatic® F 900
• Recessed for concrete infill.........................................P.74
• With solid top anti-slip surface ....................................P.76

11
Bordeaux - France
Access cover and frame

M
Ermatic® B125
• Recessed for concrete infill ....P.14
• With solid top anti-slip surface ...P.16

M
Ermatic® C250
• Recessed for concrete infill ...P.18
• With solid top anti-slip surface ..P.20

M
Ermatic® D400

1/2/3 PART COVERS


• Recessed for concrete infill ...P.22
• With solid top anti-slip surface ...P.24

M
Ermatic® E600
• Recessed for concrete infill ...P.26
• With solid top anti-slip surface ..P.28

M
Ermatic® F900
• Recessed for concrete infill ...P.30
• With solid top anti-slip surface ..P.32

Ermatic®
1/2/3 - PART COVERS
Designed to cover access and inspection chambers for a wide
variety of underground services, this is the simplest form of
the Ermatic® range, consisting of standard units made up of
one, two or three covers within a peripheral frame. This section
covers a wide variety of clear opening sizes from 300 x 300 mm
up to 3040 x 1200 mm. Cover types include recessed for
concrete infill and solid top with anti-slip surface, in all loading
classes from B 125 to F 900.

For covers of larger dimensions:


• Duct covers
• Covers for the removal of large items of plant or machinery
Please refer to the sections “Duct Covers” and “Beamed
Multiple Covers”.

13
ERMATIC® COVERS
B125

Recommended Rebate Cover Opening Direction

100 100

200 a 200
100

200
b
200

Cover recessed for filling with 40MPA concrete Reinforcing webs 25 mm below upper surface
(See recommendations on p. 84)
100

50 60
80

100
b

Dimensions in mm

14
ERMATIC® COVERS
B125
1/2/3 - part covers recessed for concrete infill

Clear opening NORINCO Over frame Number Place of installation


dimensions Reference dimensions of covers
a x b (mm) Length. x Width. x Height. (mm) Footways,
pedestrian areas and
750 x 300 ER2R 075 030 860 x 500 x 80 I
comparable areas,
1520 x 300 ER2R 152 030 1630 x 500 x 80 II
2290 x 300 ER2R 229 030 2400 x 500 x 80 III B125 car parks or car
parking decks
450 x 450 ER2R 045 045 560 x 650 x 80 I
600 x 450 ER2R 060 045 710 x 650 x 80 I

1/2/3 PART COVERS


900 x 450 ER2R 090 045 1010 x 650 x 80 I
920 x 450 ER2R 092 045 1030 x 650 x 80 II Group 2 and lower
1070 x 450 ER2R 107 045 1180 x 650 x 80 II As per EN124: 1994
1220 x 450 ER2R 122 045 1330 x 650 x 80 II
1390 x 450 ER2R 139 045 1500 x 650 x 80 III Specification
1520 x 450 ER2R 152 045 1630 x 650 x 80 II
• ERMATIC® B 125 Access Cover and
1540 x 450 ER2R 154 045 1650 x 650 x 80 III
frame
1820 x 450 ER2R 182 045 1930 x 650 x 80 II • Cover recessed for concrete infill
1840 x 450 ER2R 184 045 1950 x 650 x 80 III • Clear opening (a x b) in mm
2140 x 450 ER2R 214 045 2250 x 650 x 80 III Reference ER2R (a x b) in cm
2440 x 450 ER2R 244 045 2550 x 650 x 80 III • Machined vertical and horizontal
2740 x 450 ER2R 274 045 2850 x 650 x 80 III contact faces
600 x 600 ER2R 060 060 710 x 800 x 80 I • Ductile cast iron according
750 x 600 ER2R 075 060 860 x 800 x 80 I to ISO 1083 and EN 1563.
900 x 600 ER2R 090 060 1010 x 800 x 80 I • Quality assurance by third party
1220 x 600 ER2R 122 060 1330 x 800 x 80 II certification to ISO 9001: 2000
1370 x 600 ER2R 137 060 1480 x 800 x 80 II
1520 x 600 ER2R 152 060 1630 x 800 x 80 II Option verrouillage
1670 x 600 ER2R 167 060 1780 x 800 x 80 II (composed of 4 stainless steel bolts)
1820 x 600 ER2R 182 060 1930 x 800 x 80 II
Standard locking (VCHC)
1840 x 600 ER2R 184 060 1950 x 800 x 80 III
or security locking (VOTC)
1990 x 600 ER2R 199 060 2100 x 800 x 80 III
Add suffix to
2140 x 600 ER2R 214 060 2250 x 800 x 80 III
reference
2290 x 600 ER2R 229 060 2400 x 800 x 80 III
2440 x 600 ER2R 244 060 2550 x 800 x 80 III
2590 x 600 ER2R 259 060 2700 x 800 x 80 III For example:
2740 x 600 ER2R 274 060 2850 x 800 x 80 III ER2R 060 060 VCHC
600 x 750 ER2R 060 075 710 x 950 x 80 I (see detail on p. 3)
750 x 750 ER2R 075 075 860 x 950 x 80 I
1220 x 750 ER2R 122 075 1330 x 950 x 80 II
1370 x 750 ER2R 137 075 1480 x 950 x 80 II Adjusting bolts
1520 x 750 ER2R 152 075 1630 x 950 x 80 II In order to facilitate
1840 x 750 ER2R 184 075 1950 x 950 x 80 III the levelling of
1990 x 750 ER2R 199 075 2100 x 950 x 80 III ERMATIC systems,
2140 x 750 ER2R 214 075 2250 x 950 x 80 III adjusting bolts are
2290 x 750 ER2R 229 075 2400 x 950 x 80 III supplied with the
600 x 900 ER2R 060 090 710 x 1100 x 80 I products. These bolts
will allow, if necessary,
750 x 900 ER2R 075 090 860 x 1100 x 80 I to adjust the height of
1220 x 900 ER2R 122 090 1330 x 1100 x 80 II the system to the final level
1370 x 900 ER2R 137 090 1480 x 1100 x 80 II and correct any possible defects of the
1520 x 900 ER2R 152 090 1630 x 1100 x 80 II civil work.
1840 x 900 ER2R 184 090 1950 x 1100 x 80 III
1990 x 900 ER2R 199 090 2100 x 1100 x 80 III Lifting
2140 x 900 ER2R 214 090 2250 x 1100 x 80 III Pair of EM keys (weight 8 kg per pair)
2290 x 900 ER2R 229 090 2400 x 1100 x 80 III see details on handling p. 85
500 x 1000 ER2R 050 100 680 x 1200 x 80 I
1020 x 1000 ER2R 102 100 1200 x 1200 x 80 II
1540 x 1000 ER2R 154 100 1720 x 1200 x 80 III
2060 x 1000 ER2R 206 100 2240 x 1200 x 80 IIII

Installation
See recommendations p. 79

Infilling of recessed covers


See recommendations p. 84
How to specify
See example p. 88
15
ERMATIC® COVERS
B125

Recommended Rebate Cover Opening Direction

100 100
100

200 a 200
200
b
200

Solid top cover with anti-slip surface

80 110
max.
100

100
b

Dimensions in mm

16
ERMATIC® COVERS
B125
1/2/3 - part covers with solid top anti-slip surface

Clear opening NORINCO Over frame Number Place of installation


dimensions Reference dimensions of covers
a x b (mm) Length. x Width. x Height. (mm) Footways,
pedestrian areas and
300 x 300 ER2S 030 030 410 x 500 x 80 I comparable areas,
620 x 300 ER2S 062 030 730 x 500 x 80 II B125 car parks or car
940 x 300 ER2S 094 030 1050 x 500 x 80 III parking decks

450 x 450 ER2S 045 045 560 x 650 x 80 I

1/2/3 PART COVERS


920 x 450 ER2S 092 045 1030 x 650 x 80 II Group 2 and lower
As per EN124: 1994
1390 x 450 ER2S 139 045 1500 x 650 x 80 III
600 x 600 ER2S 060 060 710 x 800 x 80 I
Specification
1220 x 600 ER2S 122 060 1330 x 800 x 80 II
• ERMATIC® B 125 Access Cover and
1840 x 600 ER2S 184 060 1950 x 800 x 80 III frame
750 x 600 ER2S 075 060 860 x 800 x 80 I • Solid to cover with anti-slip surface
• Clear opening (a x b) in mm
1520 x 600 ER2S 152 060 1630 x 800 x 80 II Reference ER2S (a x b) in cm
2290 x 600 ER2S 229 060 2400 x 800 x 80 III • Machined vertical and horizontal
contact faces
750 x 750 ER2S 075 075 860 x 950 x 80 I • Ductile cast iron according
1520 x 750 ER2S 152 075 1630 x 950 x 80 II to ISO 1083 and EN 1563
• Quality assurance by third party
2290 x 750 ER2S 229 075 2400 x 950 x 80 III certification to ISO 9001: 2000
600 x 900 ER2S 060 090 710 x 1100 x 80 I
Option verrouillage
750 x 900 ER2S 075 090 860 x 1100 x 80 I
(composed of 4 stainless steel bolts)
900 x 900 ER2S 090 090 1010 x 1100 x 80 I
Standard locking (VCHC)
1220 x 900 ER2S 122 090 1330 x 1100 x 80 II or security locking (VOTC)
1370 x 900 ER2S 137 090 1480 x 1100 x 80 II Add suffix to
reference
1520 x 900 ER2S 152 090 1630 x 1100 x 80 II
1670 x 900 ER2S 167 090 1780 x 1100 x 80 II For example:
1820 x 900 ER2S 182 090 1930 x 1100 x 80 II ER2S 060 060 VCHC
(see detail on p. 3)
1840 x 900 ER2S 184 090 1950 x 1100 x 80 III
1990 x 900 ER2S 199 090 2100 x 1100 x 80 III
2140 x 900 ER2S 214 090 2250 x 1100 x 80 III Adjusting bolts
2290 x 900 ER2S 229 090 2400 x 1100 x 80 III In order to facilitate
the levelling of
2440 x 900 ER2S 244 090 2550 x 1100 x 80 III ERMATIC systems,
2590 x 900 ER2S 259 090 2700 x 1100 x 80 III adjusting bolts are
supplied with the
2740 x 900 ER2S 274 090 2850 x 1100 x 80 III products. These bolts
will allow, if necessary,
to adjust the height of
the system to the final level
and correct any possible defects of the
civil work.

Lifting
Pair of EM keys (weight 8 kg per pair)
see details on handling p. 85

Installation
See recommendations p. 79

How to specify
See example p. 88
17
ERMATIC® COVERS
C250

*Cover
recessed for
small element paving

*This module is also suitable for duct


covers and beamed multiple units.

Recommended Rebate Cover Opening Direction

100 100

200 a 200
100

200
b
200

Cover recessed for filling with 40MPA concrete


Reinforcing webs 25 mm below upper surface
(See recommendations on p. 84)

50
100

80 135
max.

100
b
Dimensions in mm

18
ERMATIC® COVERS
C250
1/2/3 - part covers recessed for concrete infill or for small element paving

Clear opening NORINCO Over frame Number Place of installation


dimensions Reference dimensions of covers
Parking and yard
a x b (mm) Length. x Width. x Height. (mm)
areas for all types
750 x 300 ER3R 075 030 860 x 500 x 80 I of road vehicles,
1520 x 300 ER3R 152 030 1630 x 500 x 80 II forecourts and
C250
2290 x 300 ER3R 229 030 2400 x 500 x 80 III service areas.
450 x 450 ER3R 045 045 560 x 650 x 80 I
600 x 450 ER3R 060 045 710 x 650 x 80 I

1/2/3 PART COVERS


900 x 450 ER3R 090 045 1010 x 650 x 80 I Group 3 and lower
920 x 450 ER3R 092 045 1030 x 650 x 80 II As per EN124: 1994
1070 x 450 ER3R 107 045 1180 x 650 x 80 II
1220 x 450 ER3R 122 045 1330 x 650 x 80 II
1390 x 450 ER3R 139 045 1500 x 650 x 80 III Specification
1520 x 450 ER3R 152 045 1630 x 650 x 80 II • ERMATIC® C 250 Access Cover and
1540 x 450 ER3R 154 045 1650 x 650 x 80 III frame
1820 x 450 ER3R 182 045 1930 x 650 x 80 II • Cover recessed for concrete infill
1840 x 450 ER3R 184 045 1950 x 650 x 80 III • Clear opening (a x b) in mm
2140 x 450 ER3R 214 045 2250 x 650 x 80 III Reference ER3R (a x b) in cm
2440 x 450 ER3R 244 045 2550 x 650 x 80 III • Machined vertical and horizontal
2740 x 450 ER3R 274 045 2850 x 650 x 80 III contact faces
600 x 600 ER3R 060 060 710 x 800 x 80 I • Ductile cast iron according
750 x 600 ER3R 075 060 860 x 800 x 80 I to ISO 1083 and EN 1563
900 x 600 ER3R 090 060 1010 x 800 x 80 I • Quality assurance by third party
1220 x 600 ER3R 122 060 1330 x 800 x 80 II certification to ISO 9001: 2000
1370 x 600 ER3R 137 060 1480 x 800 x 80 II
1520 x 600 ER3R 152 060 1630 x 800 x 80 II Option verrouillage
1670 x 600 ER3R 167 060 1780 x 800 x 80 II (composed of 4 stainless steel bolts)
1820 x 600 ER3R 182 060 1930 x 800 x 80 II Standard locking (VCHC)
1840 x 600 ER3R 184 060 1950 x 800 x 80 III or security locking (VOTC)
1990 x 600 ER3R 199 060 2100 x 800 x 80 III Add suffix to
2140 x 600 ER3R 214 060 2250 x 800 x 80 III reference.
2290 x 600 ER3R 229 060 2400 x 800 x 80 III
2440 x 600 ER3R 244 060 2550 x 800 x 80 III
2590 x 600 ER3R 259 060 2700 x 800 x 80 III For example:
2740 x 600 ER3R 274 060 2850 x 800 x 80 III ER3R 060 060 VCHC
600 x 750 ER3R 060 075 710 x 950 x 80 I (see detail on p. 3)
750 x 750 ER3R 075 075 860 x 950 x 80 I
1220 x 750 ER3R 122 075 1330 x 950 x 80 II
1370 x 750 ER3R 137 075 1480 x 950 x 80 II Adjusting bolts
1520 x 750 ER3R 152 075 1630 x 950 x 80 II In order to facilitate
1840 x 750 ER3R 184 075 1950 x 950 x 80 III the levelling of
1990 x 750 ER3R 199 075 2100 x 950 x 80 III ERMATIC systems,
2140 x 750 ER3R 214 075 2250 x 950 x 80 III adjusting bolts are
supplied with the
2290 x 750 ER3R 229 075 2400 x 950 x 80 III products. These bolts
600 x 900 ER3R 060 090 710 x 1100 x 80 I will allow, if necessary,
750 x 900 ER3R 075 090 860 x 1100 x 80 I to adjust the height of
1220 x 900 ER3R 122 090 1330 x 1100 x 80 II the system to the final level
1370 x 900 ER3R 137 090 1480 x 1100 x 80 II and correct any possible defects of the
1520 x 900 ER3R 152 090 1630 x 1100 x 80 II civil work.
1840 x 900 ER3R 184 090 1950 x 1100 x 80 III Lifting
1990 x 900 ER3R 199 090 2100 x 1100 x 80 III
Pair of EM keys (weight 8 kg per pair)
2140 x 900 ER3R 214 090 2250 x 1100 x 80 III
see details on handling p. 85
2290 x 900 ER3R 229 090 2400 x 1100 x 80 III
500 x 1000 ER3R 050 100 680 x 1200 x 80 I
1020 x 1000 ER3R 102 100 1200 x 1200 x 80 II
1540 x 1000 ER3R 154 100 1720 x 1200 x 80 III
2060 x 1000 ER3R 206 100 2240 x 1200 x 80 IIII
750 x 1200 ER3R 075 120 860 x 1400 x 80 I
1520 x 1200 ER3R 152 120 1630 x 1400 x 80 II
2290 x 1200 ER3R 229 120 2400 x 1400 x 80 III Installation
See recommendations p. 79
Recessed for block paving (allows the insertion of small element paving - max. height 100mm)
600 x 600 ER3P 060 060 710 x 800 x 80 I Infilling of recessed covers
1220 x 600 ER3P 122 060 1330 x 800 x 80 II See recommendations p. 84
1840 x 600 ER3P 184 060 1950 x 800 x 80 III
How to specify
See example p. 88
19
ERMATIC® COVERS
C250

Recommended Rebate Cover Opening Direction

100 100

200 a 200
100

200
b
200

Solid top cover with anti-slip surface

80 110
max.
100

100
b

Dimensions in mm

20
ERMATIC® COVERS
C250
1/2/3 - part solid top covers with solid top anti-slip surface or with removable plug

Clear opening NORINCO Over frame Number Place of installation


dimensions Reference dimensions of covers
a x b (mm) Length. x Width. x Height. (mm) Parking and yard
areas for all types
300 x 300 ER3S 030 030 410 x 500 x 80 I of road vehicles,
620 x 300 ER3S 062 030 730 x 500 x 80 II C250 forecourts and
940 x 300 ER3S 094 030 1050 x 500 x 80 III service areas.
450 x 450 ER3S 045 045 560 x 650 x 80 I

1/2/3 PART COVERS


920 x 450 ER3S 092 045 1030 x 650 x 80 II Group 3 and lower
As per EN124: 1994
139 x 045 ER3S 139 045 1500 x 650 x 80 III
600 x 600 ER3S 060 060 710 x 800 x 80 I
1220 x 600 ER3S 122 060 1330 x 800 x 80 II Specification
1840 x 600 ER3S 184 060 1950 x 800 x 80 III • ERMATIC® C 250 Access Cover and
frame
750 x 750 ER3S 075 075 860 x 950 x 80 I • Solid to cover with anti-slip surface
1520 x 750 ER3S 152 075 1630 x 950 x 80 II • Clear opening (a x b) in mm
2290 x 750 ER3S 229 075 2400 x 950 x 80 III Reference ER3S (a x b) in cm
• Machined vertical and horizontal
600 x 900 ER3S 060 090 710 x 1100 x 80 I contact faces
750 x 900 ER3S 075 090 860 x 1100 x 80 I • Ductile cast iron according
to ISO 1083 and EN 1563
900 x 900 ER3S 090 090 1010 x 1100 x 80 I • Quality assurance by third party
1220 x 900 ER3S 122 090 1330 x 1100 x 80 II certification to ISO 9001: 2000
1370 x 900 ER3S 137 090 1480 x 1100 x 80 II Option verrouillage
1520 x 900 ER3S 152 090 1630 x 1100 x 80 II (composed of 4 stainless steel bolts)
1670 x 900 ER3S 167 090 1780 x 1100 x 80 II
1820 x 900 ER3S 182 090 1930 x 1100 x 80 II Standard locking (VCHC)
1840 x 900 ER3S 184 090 1950 x 1100 x 80 III or security locking (VOTC)
Add suffix to
1990 x 900 ER3S 199 090 2100 x 1100 x 80 III reference.
2140 x 900 ER3S 214 090 2250 x 1100 x 80 III
2290 x 900 ER3S 229 090 2400 x 1100 x 80 III
For example:
2440 x 900 ER3S 244 090 2550 x 1100 x 80 III ER3S 060 060 VCHC
2590 x 900 ER3S 259 090 2700 x 1100 x 80 III (see detail on p. 3)
2740 x 900 ER3S 274 090 2850 x 1100 x 80 III Adjusting bolts
In order to facilitate
the levelling of
ERMATIC systems,
adjusting bolts are
supplied with the
products. These bolts
will allow, if necessary,
to adjust the height of
the system to the final level
and correct any possible defects of the
civil work.

Cover with removable plug (250mm diameter clear opening positioned centrally in cover) Lifting
Pair of EM keys (weight 8 kg per pair)
600 x 600 ER3T 060 060 710 x 800 x 80 I see details on handling p. 85
1220 x 600 ER3T 122 060 1330 x 800 x 80 II
1840 x 600 ER3T 184 060 1950 x 800 x 80 III
900 x 900 ER3T 090 090 1010 x 1100 x 80 I
1820 x 900 ER3T 182 090 1930 x 1100 x 80 II
2740 x 900 ER3T 274 090 2850 x 1100 x 80 III
One removable plug per unit unless specifically requested
Installation
See recommendations p. 79

How to specify
See example p. 88
21
ERMATIC® COVERS
D400

Recommended Rebate Cover Opening Direction

170 170
170

250 a 250
250
b
250

Cover recessed for filling with 40MPA concrete


(See recommendations on p. 84)
80
180
150 max.
170

110
b
Dimensions in mm

22
ERMATIC® COVERS
D400
1/2/3 - part covers recessed for concrete infill

Clear opening NORINCO Over frame Number Place of installation


dimensions Reference dimensions of covers
a x b (mm) Length. x Width. x Height. (mm) Carriageways
of roads (including
600 x 600 ER5R 060 060 VCHC 770 x 820 x 150 I pedestrian streets),
750 x 600 ER5R 075 060 VCHC 920 x 820 x 150 I D400 hard shoulders and
1220 x 600 ER5R 122 060 VCHC 1390 x 820 x 150 II parking areas for all
types of road vehicles.
1370 x 600 ER5R 137 060 VCHC 1540 x 820 x 150 II

1/2/3 PART COVERS


1520 x 600 ER5R 152 060 VCHC 1690 x 820 x 150 II Group 4 and lower
1840 x 600 ER5R 184 060 VCHC 2010 x 820 x 150 III As per EN124: 1994
1990 x 600 ER5R 199 060 VCHC 2160 x 820 x 150 III
Specification
2140 x 600 ER5R 214 060 VCHC 2310 x 820 x 150 III
• ERMATIC® D 400 Access Cover and
2290 x 600 ER5R 229 060 VCHC 2460 x 820 x 150 III frame
600 x 750 ER5R 060 075 VCHC 770 x 970 x 150 I • Cover recessed for concrete infill
• Clear opening (a x b) in mm
**750 x 750 ER4R 075 075 VCHC 920 x 930 x 125 I
Reference ER5R (a x b) in cm
1220 x 750 ER5R 122 075 VCHC 1390 x 970 x 150 II • Machined vertical and horizontal
1370 x 750 ER5R 137 075 VCHC 1540 x 970 x 150 II contact faces
• Ductile cast iron according
**1520 x 750 ER4R 152 075 VCHC 1690 x 930 x 125 II to ISO 1083 and EN 1563
1840 x 750 ER5R 184 075 VCHC 2010 x 970 x 150 III • Quality assurance by third party,
certification to ISO 9001: 2000
1990 x 750 ER5R 199 075 VCHC 2160 x 970 x 150 III
2140 x 750 ER5R 214 075 VCHC 2310 x 970 x 150 III Locking
composed of 4 stainless steel bolts
**2290 x 750 ER4R 229 075 VCHC 2460 x 930 x 125 III
600 x 900 ER5R 060 090 VCHC 770 x 1120 x 150 I
Standard locking (VCHC)
750 x 900 ER5R 075 090 VCHC 920 x 1120 x 150 I
orsecurity locking (VOTC)
** 900 X 900 ER4R 090 090 VCHC 1070 x 1080 x 125 I
For security locking
1220 x 900 ER5R 122 090 VCHC 1390 x 1120 x 150 II replace
1370 x 900 ER5R 137 090 VCHC 1540 x 1120 x 150 II VCHC suffix by VOTC
For example:
1520 x 900 ER5R 152 090 VCHC 1690 x 1120 x 150 II ER5R 060 060 VOTC
**1820 X 900 ER4R 182 090 VCHC 1990 x 1080 x 125 II (see detail on p. 3)
1840 x 900 ER5R 184 090 VCHC 2010 x 1120 x 150 III Adjusting bolts
1990 x 900 ER5R 199 090 VCHC 2160 x 1120 x 150 III In order to facilitate
the levelling of
2140 x 900 ER5R 214 090 VCHC 2310 x 1120 x 150 III ERMATIC systems,
2290 x 900 ER5R 229 090 VCHC 2460 x 1120 x 150 III adjusting bolts are
supplied with the
*2740 x 900 ER4R 274 090 VCHC 2910 x 1080 x 125 III products. These bolts
500 x 1000 ER5R 050 100 VCHC 670 x 1220 x 150 I will allow, if necessary,
to adjust the height of
1020 x 1000 ER5R 102 100 VCHC 1190 x 1220 x 150 II the system to the final level
1540 x 1000 ER5R 154 100 VCHC 1710 x 1220 x 150 III and correct any possible
defects of the civil work.
2060 x 1000 ER5R 206 100 VCHC 2230 x 1220 x 150 IIII
Lifting
Pair of EM keys (weight 8
kg per pair)
** for plans concerning these references see next page see details on handling p. 85

Installation
See recommendations p. 79

Infilling of recessed covers


See recommendations p. 84
How to specify
See example p. 88
23
DISPOSITIF
ERMATIC® ERMATIC
COVERS
B D400
125

Recommended Rebate Cover Opening Direction

150 150

200 a 200
150

200
b
200

Solid top cover with anti-slip surface


120 max.
125
150

90
b
Dimensions in mm

24
ERMATIC®
DISPOSITIF COVERS
ERMATIC
B D400
125
1/2/3 - part covers with solid top anti-slip surface

Clear opening NORINCO Over frame Number Placed’installa-


Lieu of installation
dimensions Reference dimensions of covers
a x b (mm) Length. x Width. x Height. (mm) Carriageways
of roads (including
450 x 450 ER4S 045 045 VCHC 620 x 630 x 125 I pedestrian streets)
920 x 450 ER4S 092 045 VCHC 1090 x 630 x 125 II D400 hard shoulders and
parking areas for all
1390 x 450 ER4S 139 045 VCHC 1560 x 630 x 125 III types of road vehicles.
600 x 600 ER4S 060 060 VCHC 770 x 780 x 125 I

1/2/3 PART COVERS


1220 x 600 ER4S 122 060 VCHC 1390 x 780 x 125 II Group 4 and lower
As per EN124: 1994
1840 x 600 ER4S 184 060 VCHC 2010 x 780 x 125 III
750 x 750 ER4S 075 075 VCHC 920 x 930 x 125 I Specification
1520 x 750 ER4S 152 075 VCHC 1690 x 930 x 125 II • ERMATIC® D 400 Access Cover and
frame
2290 x 750 ER4S 229 075 VCHC 2460 x 930 x 125 III • Solid to cover with ant-slip surface
• Clear opening (a x b) in mm
*800 x 800 ER4S 080 080 VCHC 970 x 1080 x 125 I
Reference ER4S (a x b) in cm
*1620 x 800 ER4S 162 080 VCHC 1790 x 1080 x 125 II • Machined vertical and horizontal
contact faces
*2440 x 800 ER4S 244 080 VCHC 2440 x 1080 x 125 III • Ductile cast iron according
600 x 900 ER4S 060 090 VCHC 770 x 1080 x 125 I to ISO 1083 and EN 1563
• Quality assurance by third party,
900 x 900 ER4S 090 090 VCHC 1070 x 1080 x 125 I certification to ISO 9001 : 2000
1220 x 900 ER4S 122 090 VCHC 1390 x 1080 x 125 II Locking
1520 x 900 ER4S 152 090 VCHC 1690 x 1080 x 125 II composed of 4 stainless steel bolts

1820 x 900 ER4S 182 090 VCHC 1990 x 1080 x 125 II


Standard locking (VCHC) or
1840 x 900 ER4S 184 090 VCHC 2010 x 1080 x 125 III
security locking (VOTC)
2140 x 900 ER4S 214 090 VCHC 2310 x 1080 x 125 III For security locking
2440 x 900 ER4S 244 090 VCHC 2610 x 1080 x 125 III replace VCHC suffix
by VOTC
2740 x 900 ER4S 274 090 VCHC 2910 x 1080 x 125 III For example:
ER4S 060 060 VOTC
1000 x 1000 ER4S 100 100 VCHC 1170 x 1180 x 125 I (see detail on p. 3)
2020 x 1000 ER4S 202 100 VCHC 2190 x 1180 x 125 II
Adjusting bolts
3040 x 1000 ER4S 304 100 VCHC 3210 x 1180 x 125 III
In order to facilitate
the levelling of
ERMATIC systems,
adjusting bolts are
supplied with the
products. These bolts
* Dimensions available in 2007 will allow, if necessary,
to adjust the height of
the system to the final level
and correct any possible
defects of the civil work.

Lifting
Pair of EM keys (weight 8 kg
per pair)
see details on handling p. 85

Installation
See recommendations p. 79

How to specify
See example p. 88
25
ERMATIC® COVERS
E600

Recommended Rebate Cover Opening Direction

170 170
170

250 a 250
250
b
250

Cover recessed for filling with 40MPA concrete


(See recommendations on p. 84)
80 180
150 max.
170

110
b
Dimensions in mm

26
ERMATIC® COVERS
E600
1/2/3 - part covers recessed for concrete infill

Clear opening NORINCO Over frame Number Place of installation


dimensions Reference dimensions of covers
a x b (mm) Length. x Width. x Height. (mm) Areas imposing
high wheel
600 x 600 ER6R 060 060 770 x 820 x 150 I loads e.g. docks,
750 x 600 ER6R 075 060 920 x 820 x 150 I E600 aircraft pavements.
1220 x 600 ER6R 122 060 1390 x 820 x 150 II
1370 x 600 ER6R 137 060 1540 x 820 x 150 II

1/2/3 PART COVERS


1520 x 600 ER6R 152 060 1690 x 820 x 150 II Group 5 and lower
1840 x 600 ER6R 184 060 2010 x 820 x 150 III As per EN124: 1994
1990 x 600 ER6R 199 060 2160 x 820 x 150 III
2140 x 600 ER6R 214 060 2310 x 820 x 150 III Specification
2290 x 600 ER6R 229 060 2460 x 820 x 150 III • ERMATIC® E 600 Access Cover and
frame
600 x 750 ER6R 060 075 770 x 970 x 150 I • Cover recessed for concrete infill
750 x 750 ER6R 075 075 920 x 970 x 150 I • Clear opening (a x b) in mm
1220 x 750 ER6R 122 075 1390 x 970 x 150 II Reference ER6R (a x b) in cm
• Machined vertical and horizontal
1370 x 750 ER6R 137 075 1540 x 970 x 150 II contact faces
1520 x 750 ER6R 152 075 1690 x 970 x 150 II • Ductile cast iron according
to ISO 1083 and EN 1563
1840 x 750 ER6R 184 075 2010 x 970 x 150 III • Quality assurance by third party
1990 x 750 ER6R 199 075 2160 x 970 x 150 III certification to ISO 9001: 2000
2140 x 750 ER6R 214 075 2310 x 970 x 150 III
Locking Option
2290 x 750 ER6R 229 075 2460 x 970 x 150 III ( composed of 4 stainless steel bolts)
600 x 900 ER6R 060 090 770 x 1120 x 150 I recommended
750 x 900 ER6R 075 090 920 x 1120 x 150 I Standard locking (VCHC)
or security locking (VOTC)
1220 x 900 ER6R 122 090 1390 x 1120 x 150 II Add suffix to
1370 x 900 ER6R 137 090 1540 x 1120 x 150 II reference.
1520 x 900 ER6R 152 090 1690 x 1120 x 150 II
1840 x 900 ER6R 184 090 2010 x 1120 x 150 III For example:
1990 x 900 ER6R 199 090 2160 x 1120 x 150 III ER6R 060 060 VCHC
(see detail on p. 3)
2140 x900 ER6R 214 090 2310 x 1120 x 150 III
2290 x900 ER6R 229 090 2460 x 1120 x 150 III Adjusting bolts
500 x 1000 ER6R 050 100 670 x 1220 x 150 I In order to facilitate
1020 x 1000 ER6R 102 100 1190 x 1220 x 150 II the levelling of
ERMATIC systems,
1540 x 1000 ER6R 154 100 1710 x 1220 x 150 III adjusting bolts are
2060 x 1000 ER6R 206 100 2230 x 1220 x 150 IIII supplied with the
products. These bolts
will allow, if necessary,
to adjust the height of
the system to the final
level and correct any
possible defects of the civil work.

Lifting
Pair of EM keys (weight 8 kg
per pair)
see details on handling p. 85

Installation
See recommendations p. 79

Infilling of recessed covers


See recommendations p. 84
How to specify
See example p. 88
27
ERMATIC® COVERS
E600

Recommended Rebate Cover Opening Direction

170 170
170

250 a 250
250
b
250

Solid top cover with anti-slip surface

160 max.
150
170

110
b

Dimensions in mm

28
ERMATIC® COVERS
E600
1/2/3 - part covers with solid top anti-slip surface

Clear opening NORINCO Over frame Number Place of installation


dimensions Reference dimensions of covers
a x b (mm) Length. x Width. x Height. (mm) Areas imposing high
wheel loads e.g. docks,
600 x 600 ER6S 060 060 770 x 820 x 150 I aircraft pavements.
750 x 600 ER6S 075 060 920 x 820 x 150 I E600
1220 x 600 ER6S 122 060 1390 x 820 x 150 II
1370 x 600 ER6S 137 060 1540 x 820 x 150 II

1/2/3 PART COVERS


1520 x 600 ER6S 152 060 1690x 820 x 150 II Group 5 and lower
1840 x 600 ER6S 184 060 2010 x 820 x 150 III As per EN124: 1994
1990 x 600 ER6S 199 060 2160 x 820 x 150 III
2140 x 600 ER6S 214 060 2310 x 820 x 150 III Specification
2290 x 600 ER6S 229 060 2460 x 820 x 150 III • ERMATIC® E 600 Access Cover and
frame
600 x 750 ER6S 060 075 770 x 970 x 150 I • Solid top cover with ant-slip surface
750 x 750 ER6S 075 075 920 x 970 x 150 I • Clear opening (a x b) in mm
1220 x 750 ER6S 122 075 1390 x 970 x 150 II Reference ER6S (a x b) in cm
• Machined vertical and horizontal
1370 x 750 ER6S 137 075 1540 x 970 x 150 II contact faces
1520 x 750 ER6S 152 075 1690 x 970 x 150 II • Ductile cast iron according
to ISO 1083 and EN 1563
1840 x 750 ER6S 184 075 2010 x 970 x 150 III • Quality assurance by third party
1990 x 750 ER6S 199 075 2160 x 970 x 150 III certification to ISO 9001: 2000
2140 x 750 ER6S 214 075 2310 x 970 x 150 III Locking Option
2290 x 750 ER6S 229 075 2460 x 970 x 150 III ( composed of 4 stainless steel bolts)
600 x 900 ER6S 060 090 770 x 1120 x 150 I recommended
Standard locking (VCHC)
750 x 900 ER6S 075 090 920 x 1120 x 150 I or security locking
(VOTC)
900 x 900 ER6S 090 090 1070 x 1120 x 150 I
Add suffix to
1220 x 900 ER6S 122 090 1390 x 1120 x 150 II reference.
1370 x 900 ER6S 137 090 1540 x 1120 x 150 II
1520 x 900 ER6S 152 090 1690 x 1120 x 150 II
For example:
1670 x 900 ER6S 167 090 1840 x 1120 x 150 II ER6S 060 060 VCHC
1820 x 900 ER6S 182 090 1990 x 1120 x 150 II (see detail on p. 3)
1840 x 900 ER6S 184 090 2010 x 1120 x 150 III Adjusting bolts
1990 x 900 ER6S 199 090 2160 x 1120 x 150 III In order to facilitate
2140 x 900 ER6S 214 090 2310 x 1120 x 150 III the levelling of
ERMATIC systems,
2290 x 900 ER6S 229 090 2460 x 1120 x 150 III adjusting bolts are
2440 x 900 ER6S 244 090 2610 x 1120 x 150 III supplied with the
products. These bolts
2590 x 900 ER6S 259 090 2760 x 1120 x 150 III will allow, if necessary,
2740 x 900 ER6S 274 090 2910 x 1120 x 150 III to adjust the height of
the system to the final
level and correct any
possible defects of the civil work.

Lifting
Pair of EM keys (weight 8 kg
per pair)
see details on handling p. 85

Installation
See recommendations p. 79

How to specify
See example p. 88
29
ERMATIC® COVERS
F900

Recommended Rebate Cover Opening Direction

170 170
170

250 a 250
250
b
250

Cover recessed for filling with 40MPA concrete


(See recommendations on p. 84)
80
180
150 max.
170

110
b
Dimensions in mm

30
ERMATIC® COVERS
ERMATIC® COVERS
F 900
F900
1/2/3 - part covers recessed for concrete infill

Clear opening NORINCO Over frame Number Place of installation


dimensions Reference dimensions of covers
a x b (mm) Length. x Width. x Height. (mm) Areas imposing
particularly high wheel
600 x 600 ER9R 060 060 770 x 820 x 150 I
loads e.g. docks,
750 x 600 ER9R 075 060 920 x 820 x 150 I F900 aircraft pavements.
1220 x 600 ER9R 122 060 1390 x 820 x 150 II Filled cover
1370 x 600 ER9R 137 060 1540 x 820 x 150 II

1/2/3 PART COVERS


1520 x 600 ER9R 152 060 1690x 820 x 150 II
Group 6 and lower
1840 x 600 ER9R 184 060 2010 x 820 x 150 III
As per EN124: 1994
1990 x 600 ER9R 199 060 2160 x 820 x 150 III
2140 x 600 ER9R 214 060 2310 x 820 x 150 III Specification
2290 x 600 ER9R 229 060 2460 x 820 x 150 III • ERMATIC® F 900 Access Cover and
frame
600 x 750 ER9R 060 075 770 x 970 x 150 I • Cover recessed for concrete infill
750 x 750 ER9R 075 075 920 x 970 x 150 I • Clear opening (a x b) in mm
1220 x 750 ER9R 122 075 1390 x 970 x 150 II Reference ER9R (a x b) in cm
• Machined vertical and horizontal
1370 x 750 ER9R 137 075 1540 x 970 x 150 II contact faces
1520 x 750 ER9R 152 075 1690 x 970 x 150 II • Ductile cast iron according
to ISO 1083 and EN 1563
1840 x 750 ER9R 184 075 2010 x 970 x 150 III
• Quality assurance by third party
1990 x 750 ER9R 199 075 2160 x 970 x 150 III certification to ISO 9001: 2000
2140 x 750 ER9R 214 075 2310 x 970 x 150 III
Locking Option
2290 x 750 ER9R 229 075 2460 x 970 x 150 III ( composed of 4 stainless steel bolts)
600 x 900 ER9R 060 090 770 x 1120 x 150 I recommended
Standard locking (VCHC)
750 x 900 ER9R 075 090 920 x 1120 x 150 I or security locking (VOTC)
1220 x 900 ER9R 122 090 1390 x 1120 x 150 II Add suffix to
1370 x 900 ER9R 137 090 1540 x 1120 x 150 II reference.
1520 x 900 ER9R 152 090 1690 x 1120 x 150 II
1840 x 900 ER9R 184 090 2010 x 1120 x 150 III
1990 x 900 ER9R 199 090 2160 x 1120 x 150 III For example:
ER9R 060 060 VCHC
2140 x900 ER9R 214 090 2310 x 1120 x 150 III (see detail on p. 3)
2290 x900 ER9R 229 090 2460 x 1120 x 150 III Adjusting bolts
500 x 1000 ER9R 050 100 670 x 1220 x 150 I In order to facilitate
1020 x 1000 ER9R 102 100 1190 x 1220 x 150 II the levelling of
ERMATIC systems,
1540 x 1000 ER9R 154 100 1710 x 1220 x 150 III adjusting bolts are
2060 x 1000 ER9R 206 100 2230 x 1220 x 150 IIII supplied with the
products. These bolts
will allow, if necessary,
to adjust the height of
the system to the final
level and correct any
possible defects of the civil work.

Lifting
Pair of EM keys (weight 8 kg per
pair) see details on handling
p. 85

Installation
See recommendations p. 79

Infilling of recessed covers


See recommendations p. 84
How to specify
See example p. 88
31
ERMATIC® COVERS
F900

Recommended Rebate Cover Opening Direction

170 170
170

250 a 250
250
b
250

Solid top cover with anti-slip surface

180 max.
150
170

110
b

Dimensions in mm

32
ERMATIC® COVERS
F900
1/2/3 - part covers with solid top anti-slip surface

Clear opening NORINCO Over frame Number Place of installation


dimensions Reference dimensions of covers
a x b (mm) Length. x Width. x Height. (mm) Areas imposing
particularly high wheel
600 x 600 ER9S 060 060 770 x 820 x 150 I
loads e.g. docks,
750 x 600 ER9S 075 060 920 x 820 x 150 I F900 aircraft pavements.
1220 x 600 ER9S 122 060 1390 x 820 x 150 II
1370 x 600 ER9S 137 060 1540 x 820 x 150 II

1/2/3 PART COVERS


1520 x 600 ER9S 152 060 1690x 820 x 150 II Group 6 and lower
1840 x 600 ER9S 184 060 2010 x 820 x 150 III As per EN124: 1994
1990 x 600 ER9S 199 060 2160 x 820 x 150 III
2140 x 600 ER9S 214 060 2310 x 820 x 150 III Specification
2290 x 600 ER9S 229 060 2460 x 820 x 150 III • ERMATIC® F 900 Access Cover and
frame
600 x 750 ER9S 060 075 770 x 970 x 150 I • Solid top cover with anti-slip surface
750 x 750 ER9S 075 075 920 x 970 x 150 I • Clear opening (a x b) in mm
1220 x 750 ER9S 122 075 1390 x 970 x 150 II Reference ER9S (a x b) in cm
• Machined vertical and horizontal
1370 x 750 ER9S 137 075 1540 x 970 x 150 II contact faces
1520 x 750 ER9S 152 075 1690 x 970 x 150 II • Ductile cast iron according
to ISO 1083 and EN 1563
1840 x 750 ER9S 184 075 2010 x 970 x 150 III
• Quality assurance by third party
1990 x 750 ER9S 199 075 2160 x 970 x 150 III certification to ISO 9001: 2000
2140 x 750 ER9S 214 075 2310 x 970 x 150 III
Locking Option (recommended)
2290 x 750 ER9S 229 075 2460 x 970 x 150 III composed of 4 stainless steel bolts
600 x 900 ER9S 060 090 770 x 1120 x 150 I
750 x 900 ER9S 075 090 920 x 1120 x 150 I Standard locking (VCHC)
or security locking (VOTC)
900 x 900 ER9S 090 090 1070 x 1120 x 150 I Add suffix to
1220 x 900 ER9S 122 090 1390 x 1120 x 150 II reference.
1370 x 900 ER9S 137 090 1540 x 1120 x 150 II
1520 x 900 ER9S 152 090 1690 x 1120 x 150 II For example:
1670 x 900 ER9S 167 090 1840 x 1120 x 150 II ER9S 060 060 VCHC
(see detail on p. 3)
1820 x 900 ER9S 182 090 1990 x 1120 x 150 II
1840 x 900 ER9S 184 090 2010 x 1120 x 150 III Adjusting bolts
1990 x 900 ER9S 199 090 2160 x 1120 x 150 III In order to facilitate
2140 x 900 ER9S 214 090 2310 x 1120 x 150 III the levelling of
ERMATIC systems,
2290 x 900 ER9S 229 090 2460 x 1120 x 150 III adjusting bolts are
2440 x 900 ER9S 244 090 2610 x 1120 x 150 III supplied with the
products. These bolts
2590 x 900 ER9S 259 090 2760 x 1120 x 150 III will allow, if necessary,
2740 x 900 ER9S 274 090 2910 x 1120 x 150 III to adjust the height of
the system to the final
level and correct any
possible defects of the civil work.

Lifting
Pair of EM keys (weight 8 kg
per pair) see details on handling
p. 85

Cover with hinged removable plug (380 x 230mm clear opening positioned centrally in cover)
Installation
750 x 750 ER9T 075 075 920 x 970 x 150 I See recommendations p. 79
1520 x 750 ER9T 152 075 1690 x 970 x 150 II
2290 x 750 ER9T 229 075 2460 x 970 x 150 III
How to specify
One hinged removable plug per unit unless specifically requested See example p. 88
33
TECHNICAL ASSISTANCE
AT THE DESIGN STAGE
The tables and drawings on the following
pages specify by loading class and type:

• The width of available clear openings from


300mm to 1200mm.
• The method of calculating the desired
length using available cover modules
• The overall dimensions of covers and
frames
• The recommended dimensions of concrete
rebates

In order to establish the characteristics of


the cover and its construction, our technical
department can supply the following dra-
wings:
• Rebate and concrete construction drawings
• Assembly and marking drawings
it is important that you state the total clear
opening length. Or, if applicable provide
a drawing showing the layout if there are
junctions or changes of direction required -
see below). These junctions and changes in
direction are only possible in classes B 125
and C 250.

NOTE:
The covers are designed to open in one direc-
tion (–o–>). It is therefore important to notify
us if continuous runs are interrupted by fixed
walls or if ducts terminate on the edges of
structures such as kerbs or quays. Bestellung : 0
NORFOND
PRODUKT ERMATICÆ ER9R447075VCHC Artikelnummer : 526961
DETAILS
3/3

- Angaben zu Gewicht, Grˆ{fle sind unverbindlich.


- ƒnderungen vorbehalten.
- Freie Verbreitung.

Peripheral reservation
Section on frame bar and cover
SG Iron to ISO 1083 / EN1563, Grade 50
170

• Operation and maintenance,


70
80

PRO
COVER Best DUK
20

ellun T
150

g:
Levelling steel shims
NOR
0 ERM FON
D
Shuttering ATIC
Æ ER9
R44
Clear Opening 707
5VC
HC
Artik

concrete filling of covers, see


elnum
mer
110 Clear Opening : 526
250 961

250 VER
MAfl
UNG
750
2/3

- Anga
- ƒnde ben
Chc key - Freie rung zu Gew

details
Verben vorb icht,
reitu ehal Grˆ{fle
ng. ten. sind
unve
Stainless steel Chc screw rbind
lich.

PLAN

Stainless steel washer 1/3


250

• We recommend that we
l )
chl¸sse
ungss Lieferumfang
Bedien im
"EM" icht
Neoprene washer (2 Stk.)(n

ND
NORFO 1
52696
er :
lnumm 170
Artike
VCHC
47075

provide technical assistance for


ER9R4
TICÆ elt CHC
ERMA verrieg
¸llung
Betonf
KT itigen
PRODU zur bause
kung
abdec
0 Reihen
F900
: TICÆ
lung ERMA
Bestel
g:
reibun Kg
Besch 946
ht :

the assembly and fixing of large


600

Gewic ER
M
A
TIC
0
447

tung A
gsrich
÷ffnun
O

O
600

ER
M
A
TIC

or complex ducts. Please


O
0
447

O
600

ER
M
A
TIC

C
Erstellt von : at Datum :14/04/2006
O
NORFOND Norinco Deutschland GmbH
Einemstrafle 5
Dieses Dokument ist Eigentum
GROUPE NORINCO D-10787 Berlin von Norfond
O und darf nicht ohne Erlaubnis
600

Tel. +49-30-200 51-0 Fax +49-30-200 51-299 ER


www.norinco.fr norinco@norinco-germany.com
M
weitergegeben
A
TIC oder vervielf‰ltigt werden.

consult us.
D

O
4470

O
600

ER
M
A
TIC

E
Grˆ{
flena O
ngab
en
in mm.
tab O
:
600

ER
M
A
1/ TIC
NOR 30
FON F
D
GRO
UPE Erst O
www NORINCO ellt
von
.nori :
nco. Norin
fr co O
750

Tel. Deuts
+49-3 Einem chlan at ER
M
A
TIC
0-200 D-10 strafl d GmbH
250

norin 51-0 787 Berline5


co@n G
Datu
orinc Fax +49-3 m:
o-ger
many 0-200 14/
.com 51-29 04/
9 O 200
6

O und
darf Dies
nicht es
ohne Doku
men
Erlau t ist
bnis Eige
weit ntum
erge von
gebe Norf
n oder ond
750 v

.
indlich
unverb
sind
ht, Grˆ{fle
Gewic
en zu alten.
- Angab ngen vorbeh
- ƒnderu itung.
in mm. Verbre d n.
ben - Freie Norfon t werde
nanga
Grˆ{fle Deckel
aus 1083 um von vervielf‰ltig
Alle {fl ISO ist Eigent en oder
n und gem‰ ent
Rahme 500-7 /2006
GS 14/04 Dokum weitergegeb
Guss : Dieses nis
Datum Erlaub
ohne
nicht
4640 at darf
und
t: 970 :
e gesam : t von land
GmbH
L‰ng t Erstell Deutsch 5
gesam trafle
NorincoEinems Berlin 51-299
Breite 7 -200
30 D-1078 Fax +49-30
1/ ny.com
51-0
ab : ND -200
@norinc
o-germa
Maflst +49-30
NORFO CO Tel. norinco
PE NORIN
orinco
.fr
GROU
www.n

Widening
Wall Slant junction

T junction

L Turn Pontevedra Port - Spain


Acces covers and frames

M
Ermatic® B125
• Recessed for concrete infill ............................P.36
• With solid top anti-slip surface ......................P.38

M
Ermatic® C250
• Recessed for concrete infill ............................P.40
• With solid top anti-slip surface ......................P.42

M
Ermatic® D400
• Recessed for concrete infill ............................P.44
• With solid top anti-slip surface ......................P.46

M
Ermatic® E600
• Recessed for concrete infill ............................P.48
• With solid top anti-slip surface ......................P.50
M Ermatic® F900
• Recessed for concrete infill ............................P.52

CONTINUOUS DUCT COVERS


• With solid top anti-slip surface ......................P.54

NORINCO Ermatic®
ACCESS COVERS
FOR CONTINUOUS DUCTS
The Ermatic® range offers a vast choice of high performance
covers designed for convenient and safe access
to continuous ducts. Used frequently in manufacturing
facilities, ports and in exhibition halls for example, the covers
permit linear access to every type of underground service
(electricity, compressed air, gas, fuels etc.) Ermatic® covers
are equally suited to ducts housing industrial machinery such
as conveyor belts etc.
Ermatic® covers protect ducts against impact damage and the
ingress of debris and aggressive chemicals. The use of
Ermatic® permits productive and unrestricted use of the
surface, when installed in circulation or storage areas.
Regardless of the traffic conditions, Ermatic® covers ensure:
• Rapid access for inspection, maintenance or repairs
• Safety due to the strength and stability of the covers
• Aesthetics: Covers with a recess for infill can be filled
with the same material as the surrounding surface to
minimise visual impact.

35
ERMATIC® COVERS
B125
NORINCO

Recommended Rebate Cover Opening Direction

100

200 a
100

200
b
200

Cover recessed for filling with 40MPA concrete Reinforcing webs 25 mm, below upper surface
(See recommendations on p. 84)
100

50 60
80

100
b

Dimensions in mm

36
ERMATIC® COVERS
B125
NORINCO

Continuous duct covers recessed for concrete infill

Design Load Place of installation


Footways, pedestrian
areas and comparable
areas, car parks or
B125 car parking decks.

Group 2 and lower


As per EN124: 1994

Specification
• Ermatic® B 125 Access Cover and
frame
• Cover recessed for concrete infill
• Clear opening (a x b) in mm
Clear opening NORINCO Length of clear Over frame Reference ER2R (a x b) in cm
span of Reference opening of the duct* dimensions • Machined vertical and horizontal
the duct contact faces

CONTINUOUS DUCT COVERS


b (mm) a (mm) Length. x Width. x Height. (mm) • Ductile cast iron according
to ISO 1083 and EN 1563
300 ER2R … 030 (N x 770) - 20 (a + 110) x (500) x 80 • Quality assurance by third
party certification to ISO 9001: 2000
450 ER2R … 045 (N1 x 470) + (N2 x 620) + (N3 x 920) - 20 (a + 110) x (650) x 80
1 2 3
Locking Option
( composed of 4 stainless steel bolts)
600 ER2R … 060 (N1 x 620) + (N2 x 770) + (N3 x 920) - 20 (a + 110) x (800) x 80
Standard locking (VCHC)
1 2 3
or security locking (VOTC)
Add suffix to
750 ER2R … 075 (N1 x 620) + (N2 x 770) - 20 (a + 110) x (950) x 80
reference.
1 2

For example:
900 ER2R … 090 (N1 x 620) + (N2 x 770) - 20 (a + 110) x (1100) x 80 ER2R … 060 VCHC
(see detail on p. 3)
1 2

Adjusting bolts
1000 ER2R … 100 (N x 520) - 20 (a + 180) x (1200) x 80
In order to facilitate the
levelling of Ermatic®
systems,adjusting bolts
are supplied with the
products. These bolts
will allow, if necessary,
* The clear opening length of duct covers is calculated by the following method: to adjust the height
• Use the maximum number of the longest cover part available unless there of the system to the final
is a specific need to keep the cover length to a minimum. Smaller covers level and correct any
possible defects of the civil work.
can be used at the termination of the duct to adjust the clear opening
length. Lifting
• N is the number of covers. Pair of EM keys (weight 8
• 470, 520, 620, 770, 920 is the overall length of covers used. kg per pair) see details on
handling p. 85

Drawings
Layout drawings are available showing the
cover/frame and the concrete rebate
dimensions. Please consult us.

Installation
See recommendations p. 79

Infilling of recessed covers


See recommendations p. 84
How to specify
See example p. 88
37
ERMATIC® COVERS
B125
NORINCO

Recommended Rebate Cover Opening Direction

100

200 a
100

200
b
200

Solid top cover with anti-slip surface


100

80 110
max.

100
b

Dimensions in mm

38
ERMATIC® COVERS
B125
NORINCO

Continuous duct covers with solid top anti-slip surface

Place of installation
Footways, pedestrian
areas and comparable
areas, car parks or car
B125 parking decks.

Group 2 and lower


As per EN124: 1994

Specification
• Ermatic® B 125 Access Cover and
frame
• Solid to cover with ant-slip surface
Clear opening NORINCO Length of clear Over frame • Clear opening (a x b) in mm
span of Reference opening of the duct* dimensions Reference ER2S (a x b) in cm
the duct • Machined vertical and horizontal
b (mm) a (mm) Length. x Width. x Height. (mm) contact faces
• Ductile cast iron according

CONTINUOUS DUCT COVERS


300 ER2S … 030 (N x 320) - 20 (a + 110) x (500) x 80
to ISO 1083 and EN 1563
• Quality assurance by third party
450 ER2S … 045 (N x 470) - 20 (a + 110) x (650) x 80 certification to ISO 9001: 2000

Locking Option
600 ER2S … 060 (N x 620) - 20 (a + 110) x (800) x 80
( composed of 4 stainless steel bolts)
Standard locking (VCHC)
or security locking (VOTC)
750 ER2S … 075 (N x 770) - 20 (a + 110) x (950) x 80 Add suffix to
reference.

900 ER2S … 090 (N1x 620) + (N2 x 770) + (N3 x 920) - 20 (a + 110) x (1100) x 80 For example:
ER2S … 060 VCHC
1 2 3
(see detail on p. 3)

Adjusting bolts
* The clear opening length of duct covers is calculated by the following
method: In order to facilitate the
levelling of Ermatic®
• Use the maximum number of the longest cover part available unless systems,adjusting bolts
there is a specific need to keep the cover length to a minimum. Smaller are supplied with the
covers can be used at the termination of the duct to adjust the clear products. These bolts
will allow, if necessary,
opening length. to adjust the height
• N is the number of covers. of the system to the final
level and correct any
• 320, 620, 770, 920 is the overall length of covers used. possible defects of the civil work.

Lifting
Pair of EM keys (weight 8
kg per pair) see details on
handling p. 85

Drawings
Layout drawings are available showing the
cover/frame and the concrete rebate
dimensions. Please consult us.

Installation
See recommendations p. 79

How to specify
See example p. 88
39
ERMATIC® COVERS
C250
NORINCO

Cover Opening Direction


Recommended Rebate

100
100

200 a
200
b
200

Cover recessed for filling with 40MPA concrete


(See recommendations on p. 84) Reinforcing webs 25 mm, below upper surface
100

50 135
80
max.

100
b

Dimensions in mm

40
ERMATIC® COVERS
C250
NORINCO

Continuous duct covers recessed for concrete infill

Place of installation
Parking and yard
areas for all types of
road vehicles,
C250 forecourts and
service areas

Group 3 and lower


As per EN124: 1994

Specification
• Ermatic® C 250 Access Cover and
frame
• Cover recessed for concrete infill
• Clear opening (a x b) in mm
Clear opening NORINCO Length of clear Over frame Reference ER3R (a x b) in cm
span of Reference opening of the duct* dimensions • Machined vertical and horizontal
the duct
contact faces
• Ductile cast iron according

CONTINUOUS DUCT COVERS


b (mm) a (mm) Length. x Width. x Height. (mm) to ISO 1083 and EN 1563
300 ER3R … 030 (N x 770) - 20 (a + 110) x (500) x 80 • Quality assurance by third party
certification to ISO 9001: 2000
450 ER3R … 045 (N1 x 470) + (N2 x 620) + (N3 x 920) - 20 (a + 110) x (650) x 80
Locking Option
1 2 3
( composed of 4 stainless steel bolts)
600 ER3R … 060 (N1 x 620) + (N2 x 770) + (N3 x 920) - 20 (a + 110) x (800) x 80 Standard locking (VCHC)
1 2 3 or security locking (VOTC)
Add suffix to
750 ER3R … 075 (N1 x 620) + (N2 x 770) - 20 (a + 110) x (950) x 80 reference.
1 2
For example:
900 ER3R … 090 (N1 x 620) + (N2 x 770) - 20 (a + 110) x (1100) x 80 ER3R … 060 VCHC
(see detail on p. 3)
1 2
Adjusting bolts
1000 ER3R … 100 (N x 520) - 20 (a + 180) x (1200) x 80
In order to facilitate the
levelling of Ermatic®
systems,adjusting bolts
are supplied with the
1200 ER3R … 120 (N x 770) - 20 (a + 180) x (1400) x 80 products. These bolts
will allow, if necessary,
to adjust the height
of the system to the final
level and correct any
possible defects of the civil work.

* The clear opening length of duct covers is calculated by the following method: Lifting
• Use the maximum number of the longest cover part available unless there Pair of EM keys (weight 8
is a specific need to keep the cover length to a minimum. Smaller covers kg per pair) see details on
can be used at the termination of the duct to adjust the clear opening handling p. 85
length.
• N is the number of covers.
• 470, 520, 620, 770, 920 is the overall length of covers used.
Drawings
Layout drawings are available showing the
cover/frame and the concrete rebate
dimensions. Please consult us.

Installation
See recommendations p. 79

Infilling of recessed covers


See recommendations p. 84
How to specify
See example p. 88
41
ERMATIC® COVERS
C250
NORINCO

Recommended Rebate Cover Opening Direction

100

200 a
100

200
b
200

Solid top cover with anti-slip surface


100

80 110
max.

100
b

Dimensions in mm

42
ERMATIC® COVERS
C250
NORINCO

Continuous duct covers with solid top anti-slip surface

Place of installation
Parking and yard
areas for all types of
road vehicles,
C250 forecourts and
service areas

Group 3 and lower


As per EN124: 1994

Specification
• Ermatic® C 250 Access Cover and
frame
• Solid to cover with anti-slip surface
Clear opening NORINCO Length of clear Over frame • Clear opening (a x b) in mm
span of Reference opening of the duct* dimensions Reference ER3S (a x b) in cm
the duct • Machined vertical and horizontal
b (mm) a (mm) Length. x Width. x Height. (mm) contact faces
• Ductile cast iron according

CONTINUOUS DUCT COVERS


300 ER3S … 030 (N x 320) - 20 (a + 110) x (500) x 80 to ISO 1083 and EN 1563
• Quality assurance by third party
600 ER3S … 060 (N x 620) - 20 (a + 110) x (800) x 80 certification to ISO 9001: 2000

Locking Option
750 ER3S … 075 (N x 770) - 20 (a + 110) x (950) x 80 ( composed of 4 stainless steel bolts)
Standard locking (VCHC)
or security locking (VOTC)
900 ER3S … 090 (N1 x 620) + (N2 x 770) + (N3 x 920) - 20 (a + 110) x (1100) x 80 Add suffix to
reference.
1 2 3

For example:
ER3S … 060 VCHC
* The clear opening length of duct covers is calculated by the following method: (see detail on p. 3)
• Use the maximum number of the longest cover part available unless there
is a specific need to keep the cover length to a minimum. Smaller covers
Adjusting bolts
can be used at the termination of the duct to adjust the clear opening In order to facilitate the
length. levelling of Ermatic®
systems,adjusting bolts
• N is the number of covers. are supplied with the
• 320, 620, 770, 920 is the overall length of covers used. products. These bolts
will allow, if necessary,
to adjust the height
of the system to the final
level and correct any
possible defects of the civil work.

Lifting
Pair of EM keys (weight 8
kg per pair) see details on
handling p. 85

Drawings
Layout drawings are available showing the
cover/frame and the concrete rebate
dimensions. Please consult us.

Installation
See recommendations p. 79

How to specify
See example p. 88
43
ERMATIC® COVERS
D400
NORINCO

Cover Opening Direction


Recommended Rebate

170
170

250 a
250
b
250

Cover recessed for filling with 40MPA concrete


(See recommendations on p. 84)
80
170

150
150 max.

110
b
Dimensions in mm

44
ERMATIC® COVERS
D400
NORINCO

Continuous duct covers recessed for concrete infill

Place of installation
Carriageways
of roads (including
pedestrian streets)
D400 hard shoulders and
parking areas for all
types of road vehicles.

Group 4 and lower


As per EN124: 1994
Clear opening NORINCO Length of clear Over frame
span of Reference opening of the duct* dimensions Specification
the duct
• Ermatic® D 400 Access Cover and
b (mm) a (mm) Length. x Width. x Height. (mm)t. frame
600 ER5R … 060 VCHC (N1 x 620) + (N2 x 770) - 20 (a + 170) x (820) x 150 • Cover recessed for concrete infill
• Clear opening (a x b) in mm
1 2
Reference ER5R (a x b) in cm
• Machined vertical and horizontal
**750 ER4R … 075 VCHC (N1 x 770) - 20 (a + 170) x (930) x 125 contact faces
• Ductile cast iron according

CONTINUOUS DUCT COVERS


to ISO 1083 and EN 1563
• Quality assurance by third party
750 ER5R … 075 VCHC (N1 x 620) + (N2 x 770) - 20 (a + 170) x (970) x 150 certification to ISO 9001: 2000
1 2
Locking
** 900 ER4R … 090 VCHC (N1 x 920) - 20 (a + 170) x (1080) x 125 ( composed of 4 stainless steel bolts)
Standard locking (VCHC)
or security locking (VOTC)
900 ER5R … 090 VCHC (N1 x 620) + (N2 x 770) - 20 (a + 170) x (1120) x 150 Add suffix to
reference.
1 2

For example:
1000 ER5R … 100 VCHC (N x 520) - 20 (a + 170) x (1220) x 150 ER5R … 060 VCHC
(see detail on p. 3)

Adjusting bolts
In order to facilitate the
* The clear opening length of duct covers is calculated by the following method: levelling of Ermatic®
• Use the maximum number of the longest cover part available unless there systems,adjusting bolts
is a specific need to keep the cover length to a minimum. Smaller covers are supplied with the
can be used at the termination of the duct to adjust the clear opening products. These bolts
will allow, if necessary,
length. to adjust the height
• N is the number of covers. of the system to the final
level and correct any
• 520, 620, 770 is the overall length of covers used. possible defects of the civil work.

Lifting
** See plans for these two references on next page Pair of EM keys (weight 8
kg per pair) see details on
handling p. 85

Drawings
Layout drawings are available showing the
cover/frame and the concrete rebate
dimensions. Please consult us.

Installation
See recommendations p. 79

Infilling of recessed covers


See recommendations p. 84
How to specify
See example p. 88
45
ERMATIC® COVERS
D400
NORINCO

Cover Opening Direction


Recommended Rebate

150
150

200 a
200
b
200

Solid top cover with anti-slip surface


150

120
max.
125

90
b
Dimensions in mm

46
ERMATIC® COVERS
D400
NORINCO

Continuous duct covers with solid top anti-slip surface

Place of installation
Carriageways of
roads (including
pedestrian streets)
D400 hard shoulders and
parking areas for all
types of road vehicles.

Group 4 and lower


As per EN124: 1994
Clear opening NORINCO Length of clear Over frame
span of Reference opening of the duct* dimensions Specification
the duct
• Ermatic® D 400 Access Cover and
b (mm) a (mm) Length. x Width. x Height. (mm) frame
450 ER4S … 045 VCHC (N x 470) - 20 (a + 170) x (630) x 125 • Solid to cover with anti-slip surface
• Clear opening (a x b) in mm
Reference ER4S (a x b) in cm
• Machined vertical and horizontal
600 ER4S … 060 VCHC (N x 620) - 20 (a + 170) x (780) x 125 contact faces
• Ductile cast iron according

CONTINUOUS DUCT COVERS


to ISO 1083 and EN 1563
750 ER4S … 075 VCHC (N x 770) - 20 (a + 170) x (930) x 125 • Quality assurance by third party
certification to ISO 9001: 2000

Locking
* 800 ER4S … 080 VCHC (N x 820) - 20 (a + 170) x (980) x 125
( composed of 4 stainless steel bolts)
Standard locking (VCHC)
or security locking (VOTC)
Add suffix to
900 ER4S … 090 VCHC (N1 x 620) + (N2 x 920) - 20 (a + 170) x (1080) x 125 reference.
1 2
For example:
1000 ER4S … 100 VCHC (N x 1020) - 20 (a + 170) x (1180) x 125 ER4S … 060 VCHC
(see detail on p. 3)

Adjusting bolts
In order to facilitate the
levelling of Ermatic®
systems,adjusting bolts
are supplied with the
products. These bolts
will allow, if necessary,
* The clear opening length of duct covers is calculated by the following method: to adjust the height
• Use the maximum number of the longest cover part available unless there of the system to the final
is a specific need to keep the cover length to a minimum. Smaller covers level and correct any
can be used at the termination of the duct to adjust the clear opening possible defects of the civil work.
length. Lifting
• N is the number of covers. Pair of EM keys (weight 8
• 620, 770, 920 is the overall length of covers used. kg per pair) see details on
handling p. 85
*Dimension available in 2007

Drawings
Layout drawings are available showing the
cover/frame and the concrete rebate
dimensions. Please consult us.

Installation
See recommendations p. 79

How to specify
See example p. 88
47
ERMATIC® COVERS
E600
NORINCO

Cover Opening Direction


Recommended Rebate

170
170

250 a
250
b
250

Cover recessed for filling with 40MPA concrete


(See recommendations on p. 84)
80 180
170

max.
150

110
b
Dimensions in mm

48
ERMATIC® COVERS
E600
NORINCO

Continuous duct covers recessed for concrete infill

Place of installation
Areas imposing high
wheel loads e.g.
docks, aircraft
E600 pavements.

Group 5 and lower


As per EN124: 1994

Spécification
• Ermatic® E 600 Access Cover and
frame
• Cover recessed for concrete infill
• Clear opening (a x b) in mm
Clear opening NORINCO Length of clear Over frame Reference ER6R (a x b) in cm
span of Reference opening of the duct* dimensions • Machined vertical and horizontal
the duct contact faces

CONTINUOUS DUCT COVERS


• Ductile cast iron according
b (mm) a (mm) Length. x Width. x Height. (mm) to ISO 1083 and EN 1563
600 ER6R … 060 (N1 x 620) + (N2 x 770) - 20 (a + 170) x (820) x 150 • Quality assurance by third party
1 2
certification to ISO 9001: 2000

750 ER6R … 075 (N1 x 620) + (N2 x 770) - 20 (a + 170) x (970) x 150 Locking Option
( composed of 4 stainless steel bolts)
1 2 recommended
Standard locking (VCHC)
900 ER6R … 090 (N1 x 620) + (N2 x 770) - 20 (a + 170) x (1120) x 150 or security locking (VOTC)
1 2
Add suffix
to reference.
1000 ER6R … 100 (N x 520) - 20 (a + 170) x (1220) x 150
For example:
ER6R … 060 VCHC
(see detail on p. 3)
Adjusting bolts
* The clear opening length of duct covers is calculated by the following method:
• Use the maximum number of the longest cover part available unless there In order to facilitate the
levelling of Ermatic®
is a specific need to keep the cover length to a minimum. Smaller covers systems,adjusting bolts
can be used at the termination of the duct to adjust the clear opening are supplied with the
length. products. These bolts
will allow, if necessary,
• N is the number of covers. to adjust the height
of the system to the final
• 520, 620, 770 is the overall length of covers used. level and correct any
possible defects of the civil work.

Lifting
Pair of EM keys (weight 8
kg per pair) see details on
handling p. 85

Drawings
Layout drawings are available showing the
cover/frame and the concrete rebate
dimensions. Please consult us.

Installation
See recommendations p. 79

Infilling of recessed covers


See recommendations p. 84
How to specify
See example p. 88
49
ERMATIC® COVERS
E600
NORINCO

Recommended Rebate Cover Opening Direction

170
170

250 a
250
b
250

Solid top cover with anti-slip surface


170

160
150 max.

110
b
Dimensions in mm

50
ERMATIC® COVERS
E600
NORINCO

Continuous duct covers with solid top anti-slip surface

Place of installation
Areas imposing high
wheel loads e.g.
docks, aircraft
E600 pavements.

Group 5 and lower


As per EN124: 1994
Clear opening NORINCO Length of clear Over frame
span of Reference opening of the duct* dimensions Spécification
the duct
• Ermatic® E 600 Access Cover and
b (mm) a (mm) Length. x Width. x Height. (mm) frame
600 ER6S … 060 (N1 x 620) + (N2 x 770) - 20 (a + 170) x (820) x 150 • Cover recessed for concrete infill
1 2
• Clear opening (a x b) in mm
Reference ER6R (a x b) in cm
750 ER6S … 075 (N1 x 620) + (N2 x 770) - 20 (a + 170) x (970) x 150 • Machined vertical and horizontal
contact faces

CONTINUOUS DUCT COVERS


1 2 • Ductile cast iron according
to ISO 1083 and EN 1563
900 ER6S … 090 (N1x 620) + (N2 x 770) + (N3 x 920) - 20 (a + 170) x (1120) x 150 • Quality assurance by third party
certification to ISO 9001: 2000
1 2 3

Locking Option
( composed of 4 stainless steel bolts)
* The clear opening length of duct covers is calculated by the following method: recommended
• Use the maximum number of the longest cover part available unless there Standard locking (VCHC)
is a specific need to keep the cover length to a minimum. Smaller covers or security locking (VOTC)
can be used at the termination of the duct to adjust the clear opening Add suffix to
length. reference.
• N is the number of covers.
For example:
• 620, 770, 920 is the overall length of covers used.
ER6S … 060 VCHC
(see detail on p. 3)
Adjusting bolts
In order to facilitate the
levelling of Ermatic®
systems,adjusting bolts
are supplied with the
products. These bolts
will allow, if necessary,
to adjust the height
of the system to the final
level and correct any
possible defects of the civil work.

Lifting
Pair of EM keys (weight 8
kg per pair) see details on
handling p. 85

Drawings
Layout drawings are available showing the
cover/frame and the concrete rebate
dimensions. Please consult us.

Installation
See recommendations p. 79

How to specify
See example p. 88
51
ERMATIC® COVERS
F900
NORINCO

Cover Opening Direction


Recommended Rebate

170
170

250 a
250
b
250

Cover recessed for filling with 40MPA concrete


(See recommendations on p. 84)
80
170

180
150 max.

110
b
Dimensions in mm

52
ERMATIC® COVERS
F900
NORINCO

Continuous duct covers recessed for concrete infill

Place of installation
Areas imposing
particularly high wheel
loads e.g. docks,
F900 aircraft pavements.
Filled cover

Group 6 and lower


As per EN124: 1994

Clear opening NORINCO Length of clear Over frame Specification


span of Reference opening of the duct* dimensions • Ermatic® F 900 Access Cover and
the duct frame
b (mm) a (mm) Length. x Width. x Height. (mm) • Cover recessed for concrete infill
600 ER9R … 060 (N1 x 620) + (N2 x 770) - 20 (a + 170) x (820) x 150 • Clear opening (a x b) in mm
Reference ER9R (a x b) in cm
1 2
• Machined vertical and horizontal
contact faces
750 ER9R … 075 (N1 x 620) + (N2 x 770) - 20 (a + 170) x (970) x 150

CONTINUOUS DUCT COVERS


• Ductile cast iron according
1 2 to ISO 1083 and EN 1563
• Quality assurance by third party
900 ER9R … 090 (N1 x 620) + (N2 x 770) - 20 (a + 170) x (1120) x 150 certification to ISO 9001: 2000
1 2 Locking Option
( composed of 4 stainless steel bolts)
1000 ER9R … 100 (N x 520) - 20 (a + 170) x (1220) x 150 recommended
Standard locking (VCHC)
or security locking (VOTC)
Add suffix to
reference.
* The clear opening length of duct covers is calculated by the following method:
• Use the maximum number of the longest cover part available unless there For example:
is a specific need to keep the cover length to a minimum. Smaller covers ER9R … 060 VCHC
can be used at the termination of the duct to adjust the clear opening (see detail on p. 3)
length.
Adjusting bolts
• N is the number of covers.
• 520, 620, 770 is the overall length of covers used. In order to facilitate the
levelling of Ermatic®
systems,adjusting bolts
are supplied with the
products. These bolts
will allow, if necessary,
to adjust the height
of the system to the final
level and correct any
possible defects of the civil work.

Lifting
Pair of EM keys (weight 8
kg per pair) see details on
handling p. 85

Drawings
Layout drawings are available showing the
cover/frame and the concrete rebate
dimensions. Please consult us.

Installation
See recommendations p. 79

Infilling of recessed covers


See recommendations p. 84
How to specify
See example p. 88
53
ERMATIC® COVERS
F900
NORINCO

Recommended Rebate Cover Opening Direction

170
170

250 a
250
b
250

Solid top cover with anti-slip surface


170

180
150 max.

110
b

Dimensions in mm

54
ERMATIC® COVERS
F900
NORINCO

Continuous duct covers with solid top anti-slip surface

Place of installation
Areas imposing
particularly high wheel
loads e.g. docks,
F900 aircraft pavements.

Group 6 and lower


As per EN124: 1994

Specification
Clear opening NORINCO Length of clear Over frame • Ermatic® F 900 Access Cover and
span of Reference opening of the duct* dimensions frame
the duct • Solid top cover with anti-slip surface
b (mm) a (mm) Length. x Width. x Height. (mm) • Clear opening (a x b) in mm
600 ER9S … 060 (N1 x 620) + (N2 x 770) - 20 (a + 170) x (820) x 150 Reference ER9S (a x b) in cm
• Machined vertical and horizontal
1 2
contact faces

CONTINUOUS DUCT COVERS


• Ductile cast iron according
750 ER9S … 075 (N1 x 620) + (N2 x 770) - 20 (a + 170) x (970) x 150
to ISO 1083 and EN 1563
1 2 • Quality assurance by third party
certification to ISO 9001: 2000
900 ER9S … 090 (N1 x 620) + (N2 x 770) + (N3 x 920) - 20 (a + 170) x (1120) x 150
Locking Option
1 2 3 ( composed of 4 stainless steel bolts)
recommended
Standard locking (VCHC)
* The clear opening length of duct covers is calculated by the following method: or security locking (VOTC)
• Use the maximum number of the longest cover part available unless there Add suffix to
is a specific need to keep the cover length to a minimum. Smaller covers reference.
can be used at the termination of the duct to adjust the clear opening
length. For example:
ER9S … 060 VCHC
• N is the number of covers. (see detail on p. 3)
• 620, 770, 920 is the overall length of covers used.
Adjusting bolts
In order to facilitate the
levelling of Ermatic®
systems,adjusting bolts
are supplied with the
products. These bolts
will allow, if necessary,
to adjust the height
of the system to the final
level and correct any
possible defects of the civil work.

Lifting
Pair of EM keys (weight 8
kg per pair) see details on
handling p. 85

Drawings
Layout drawings are available showing the
cover/frame and the concrete rebate
dimensions. Please consult us.

Installation
See recommendations p. 79

How to specify
See example p. 88
55
TECHNICAL ASSISTANCE Access covers and frame

M
AT THE DESIGN STAGE Ermatic® B 125
The tables and drawings on the follo- • Recessed for concrete infill ....P.58
wing pages specify by loading class and • With solid top anti-slip surface ..P.60
type:

M
• Possible cover clear openings from
1220 x 1370mm up to 3660 x Ermatic® C 250
5180mm • Recessed for concrete infill ....P.62
• The composition of the units (number • With solid top anti-slip surface ..P.64
of

M
covers and beams)
• The position of the beams and the Ermatic® D 400
overall dimensions of the units • Recessed for concrete infill ....P.66
• The recommended dimensions of • With solid top anti-slip surface ..P.68
concrete
rebates

M
Ermatic® E 600
• Recessed for concrete infill ....P.70
For other characteristics of the cover
and its construction, our technical
• With solid top anti-slip surface ..P.72
department can supply the following

M
drawings: Ermatic® F 900
• Rebate and concrete construction
• Recessed for concrete infill ....P.74
drawings
• Assembly and marking drawings • With solid top anti-slip surface ..P.76
It is important to state the desired
characteristics:

Ermatic®
• the loading class (B 125 - D 400…)
• the type of cover (recessed for
concrete
infill, anti-slip solid top surface…)
• the required clear opening of the PRODUKT
NORFOND

ERMATICÆ ER5R199214VCHC Artikelnummer : 515075


PLAN

1/3

unit
"EM" Bedienungsschl¸ssel

ACCESS COVERS
Bestellung : 0 (2 Stk.)(nicht im Lieferumfang)

Beschreibung : ERMATICÆ D400 Fl‰chenabdeckung zur bauseitigen Betonf¸llung verriegelt CHC

Gewicht : 1503 Kg

÷ffnungsrichtung

PRO
600 600 600 Best DUK
ellun T
g: NOR
0 ERM FON
ATIC D
E
R E
R E
R
M
A
T
IC
M
A
T
IC
M
A
T
IC
Æ ER5

If available, please supply a design


R19
921
4VC
HC
Artik
600

A D G elnu
mme
r:
515
075 VER
MAfl
UNG
O O O O O O - Anga 2/3
E
R
M
A
E
R
M
A
E
R
M
A 250 - ƒnde ben
T
IC T
IC T
IC - Freie rung zu
Gew
Verben vorb icht,
reitu ehal Grˆ{

or as-built drawing showing the civil


ng. ten. fle
sind
600

B E H
unve
rbind
1990

214
0 lich.

S
O O O O O O
DETAIL

WITH REMOVABLE BEAMS


E
R
M E
R
M E
R
M
IA
TC IA
TC IA
TC
3/3
540
750

450

construction of the chamber and its


C F I .
indlich
unverb
sind
t, Grˆ{fle
Gewich alten.
en zu vorbeh
- Angab ngen
itung.
- ƒnderuVerbre
ND - Freie
O
NORFO O O 5 O O O
51507
er :
lnumm
Artike
VCHC
99214

surrounding environment.
ER5R1
TICÆ ation
ERMA reserv
eral
Periph
KT 2140
PRODU
0
199

250

0
:
lung
170

Bestel shims
g steel
Levellin
ring
cover Shutte
20

and 540
bar
frame g 170
n on 500-7
Openin
Sectio 3, Grade Clear
/ EN156
70

1083
to ISO
SG Iron
Alle Grˆ{flenangaben in mm.
COVER Rahmen und Deckel aus Guss
L‰nge gesamt : 2350
GS 500-7 gem‰{fl ISO 1083
Breite gesamt : 2360
80

450
Maflstab : 1/ 20 Erstellt von : at Datum : 14/04/2006
- Angaben zu Gewicht, Grˆ{fle sind unverbindlich.
- ƒnderungen 250

NOTE:
vorbehalten.
150

NORFOND Norinco Deutschland GmbH Dieses Dokument ist Eigentum von Norfond und darf nicht ohne
Einemstrafle 5
0

- Freie Erlaubnis
Verbreitung.
weitergegeben oder vervielf‰ltigt werden.
199

GROUPE NORINCO D-10787 Berlin


www.norinco.fr Tel. +49-30-200 51-0 Fax +49-30-200 51-299 685 BEAM
norinco@norinco-germany.com g N ON
Openin SECTIO
Clear VERSE Frame
TRANS
110 145
5

Alle
150

Grˆ{ Wall
boxe
250

flena
ngab
500

Mafl en
stab in mm.
:
1/
NOR Chc
25
screw
FON

Covers and frames are designed


ss steel
GRO D
Stainle Erst 0
UPE elltBeam IPE36
www NOR
key .nor von
Chc
incoINCO :
.fr Norinc
o Deutsc at
r Einems

Large chambers are neccessary for cable drawpits manifold

BEAM MULTIPLE COVERS


hland
washe Tel. D-107 trafle GmbH
ss steel Fax +49-30 87 5bolts
norinco +49-30
-200 g
Berlin Datu
Stainle @norinLevellin
-200 51-0 m:
51-29
co-germ
9 14/
any.co 04/
m 200
6
360 Dies
r nich

with removable beams fitted in


ene
washe t ohne es Doku
Neopr Erla men
ubni t ist
s weit Eige
erge ntum
gebe von
n oder Norf
ond
verv und
ielf‰ darf
ltigt
werd

chambers, and for the servicing of large items of machinery.


boxes en.
and
on beam
500

section

housing boxes located under the


udinal
Longit
470

0
IPE36
BEAM
VABLE
REMO

frame. Therefore whenever the Beamed multiple Ermatic® covers ensure complete, unobs-
170

d und n.
g Norfon t werde
Openin um von f‰ltig
Clear verviel
ist Eigent n oder
ent
/2006 Dokum gegebe
14/04 Dieses nis weiter
:
Erlaub

product is not installed on top of


Datum ohne
nicht
darf
at
: GmbH
t von

tructed access to chambers from 1220mm span and above.


170 hland5
Erstell 9
o Deutsc
strafle 51-29
Norinc Einem 87 Berlin 0-200
D-107 Fax +49-3 .com
51-0 inco-germany
ND 0-200
NORFO CO +49-3norinco@nor
Tel.
E NORIN .fr
GROUP orinco
www.n

a solid and continuous wall


structure, it is important to They are constructed from standard covers, seating and sea-
design an appropriate bearing ling on intermediate removable support beams.
structure (concrete beam for These covers are available in different loading classes, in a
example).
wide variety of sizes from 1220mm span x 1370mm long.
The covers are designed to open in one
direction (–o–>). It is therefore impor-
tant to notify us if fixed walls interrupt
multiple covers or if the unit abuts upon
the edges of structures such as kerbs
or quays.

• Operation and maintenance, installa-


tion,
concrete filling of covers, see details.

• We recommend that we provide tech-


nical Assistance for the assembly and
installation of large units. Please
consult us. Manchester Airport - UK

56 57
ERMATIC® COVERS ERMATIC® COVERS
B125 B125
NORINCO NORINCO

Multiple covers with removable beams


Covers recessed for concrete infill
Specification Place of installation
• ERMATIC® B 125 multiple • Machined horizontal and Footways, pedestrian
access covers with removable vertical contact faces areas and comparable
beams • Ductile cast iron to ISO 1083 areas, car parks or
• Covers recessed for and EN 1563 B125 car parking decks.
concrete infill • Galvanised mild steel beams
• Clear opening (a x b) in mm • Quality assurance by third
Reference ER2R (a x b) in cm party certification to
ISO 9001: 2000
Group 2 and lower
As per EN124: 1994
Standard clear opening dimensions: a x b (in cm)
For other clear opening dimensions, please consult us Norinco’s reference: ER2R (a x b) in cm
*Clear opening is reduced of 10 cm between boxes
2 covers 3 covers 4 covers 5 covers Removable
I beam 2 beams 3 beams 4 beams beam

b clear used

137
152
167
182
197

214
229
244
259
274
289
304

291
306
321
336
351
366
381
396
411

368
383
398
413
428
443
458
473
488
503
518
opening
a (cm) (mm)

122 UPE200
137 h = 195
to 4th beam centre 2
152 h’ = 260
covers
to 3rd beam centre 167 H = 300
182
Recommended rebate to 2nd beam centre
184
to 1st beam centre 1990
199
214
3 HEA180
229
covers h = 290
244
h’ = 355
259
H = 400
274

246
261
276
4 291
Leveling bolts covers 306
321
336
351
366 3660
Overall dimensions of cover (a+280mm) x (b+200mm) x (beam box height : h’

BEAM MULTIPLE COVERS


Beam centres (see section opposite)

137
152
167
182
197

214
229
244
259
274
289
304

291
306
321
336
351
366
381
396
411

368
383
398
413
428
443
458
473
488
503
518
Clear opening in cm

2225 1455 685


2375 1455 685
2525 1605 685

2525 1605 835

2675 1755 835

2825 1755 835

2975 1905 835

2975 1905 985

3125 2055 985


1455 685

1605 685
1605 835

1755 835

1905 835

1905 985

2055 985
685
685

835

835
985

2995 2225 1455 685


3145 2375 1455 685

3295 2375 1605 685

3295 2525 1605 835


3445 2525 1755 835

3595 2675 1755 835

3745 2825 1755 835

3895 2825 1905 835

3895 2975 1905 985

4045 2975 2055 985

4195 3125 2055 985


W
Cover opening direction

Beam
Leveling bolts X To 2nd beam centre
centres
(mm) Y To 3rd beam centre

Z To 4th beam centre


Removable beam

Lifting Locking option Drawings


Pair of EM keys (weight 8 kg/pair) (composed of 4 stainless steel bolts) Layout drawings are available showing the
see details on p. 85 cover/frame and the
Standard locking (VCHC)
concrete rebate dimensions. Please
or security locking (VOTC) consult us.
Add suffix to
reference.
Adjusting bolts
In order to facilitate the
levelling of ERMATIC® For example : Installation:
systems,adjusting bolts are ER2R (a)(b) VCHC see recommendations on p. 79
supplied with the products. (see detail on p. 3)
These bolts will allow, if Infilling of recessed covers:
Cover recessed for filling with 40 MPA concrete necessary, to adjust the height see recommendations on p. 84
Dimensions in mm
See recommendations on p. 84 of the system to the final
level and correct any How to specify:
possible defects of the civil work. see detail on P. 88
58 59
ERMATIC® COVERS ERMATIC® COVERS
B125 B125
NORINCO NORINCO

Multiple covers with removable beams


Solid top cover with anti-slip surface
Specification Place of installation
• ERMATIC® B 125 multiple • Machined horizontal and vertical Footways, pedestrian
access covers with removable contact faces areas and comparable
beams • Ductile cast iron according areas, car parks or
• Solid top cover with anti-slip to ISO 1083 and EN 1563 B125 car parking decks.
surface • Galvanised mild steel Beams
• Clear opening (a x b) in mm • Quality assurance by third party
Reference ER2S (a x b) in cm certification to ISO 9001: 2000
Group 2 areas and lower
As per EN124: 1994
Standard clear opening dimensions: a x b (in cm)
For other clear opening dimensions, please consult us
*Clear opening is reduced of 10 cm between boxes Norinco’s reference: ER2S (a x b) in cm
2 covers 3 covers 4 covers 5 covers
1 beam 2 beams 3 beams 4 beams Removable
beam
b

137
152
167
182
197

214
229
244
259
274
289
304

291
306
321
336
351
366
381
396
411

368
383
398
413
428
443
458
473
488
503
518
clear used
a opening
(cm) (mm)
122
137 UPE200
2 152 h = 195
covers 167 h’ = 260
to 4th beam centre
182 H = 300
to 3rd beam centre
184
Recommended rebate
to 2nd beam centre 199 1990
214
to 1st beam centre
3 229 HEA180
covers 244 h = 290
259 h’ = 355
274 H = 400
246
261
276
Leveling bolts
291
4 306
covers 321
336
351
366 3660
Beam centres (see section opposite) Overall dimensions of cover (a+280mm) x (b+200mm) x (beam box height = h’)

BEAM MULTIPLE COVERS


137
152
167
182
197

214
229
244
259
274
289
304

291
306
321
336
351
366
381
396
411

368
383
398
413
428
443
458
473
488
503
518
Clear opening in cm

Leveling bolts

2225 1455 685


2375 1455 685
2525 1605 685

2525 1605 835

2675 1755 835

2825 1755 835

2975 1905 835

2975 1905 985

3125 2055 985


1455 685
1605 685

1605 835

1755 835

1905 835

1905 985

2055 985

2995 2225 1455 685


3145 2375 1455 685
3295 2375 1605 685
3295 2525 1605 835
3445 2525 1755 835

3595 2675 1755 835

3745 2825 1755 835

3895 2825 1905 835

3895 2975 1905 985

4045 2975 2055 985

4195 3125 2055 985


685

685

835

835
985
W
Beam
X To 2nd beam centre
centres
(mm) Y To 3rd beam centre
Cover opening direction

Z To 4th beam centre


Removable beam

Lifting Locking option Drawings


Pair of EM keys (weight 8 kg/pair) (composed of 4 stainless steel bolts) Layout drawings are available showing the
see details on p. 85 cover/frame and the concrete rebate
Standard locking (VCHC)
dimensions. Please consult us.
or security locking (VOTC)
Add suffix to
reference.

Adjusting bolts
In order to facilitate the For example:
levelling of ERMATIC® ER2S (a)(b) VCHC
systems,adjusting bolts are Installation
(see detail on p. 3) see recommendations on p. 79
supplied with the products.
These bolts will allow, if
Dimensions in mm Solid top cover with anti-slip surface necessary, to adjust the height
of the system to the final How to specify
level and correct any see detail on p. 88
60 possible defects of the civil work. 61
ERMATIC® COVERS ERMATIC® COVERS
C250 C250
NORINCO NORINCO

Multiple covers with removable beams


Covers recessed for concrete infill
Specification Place of installation
• ERMATIC® C 250 multiple • Ductile cast iron according Parking and yard
access covers with removable to ISO 1083 and EN 1563 areas for all types of
beams • Galvanised mild steel beams road vehicles, fore-
• Covers recessed for concrete • Quality assurance by third C250 courts and service
infill party certification to areas.
• Clear opening (a x b) in mm ISO 9001: 2000
Reference ER3R (a x b) in cm
• Machined horizontal and
vertical contact faces Group 3 and lower
As per EN124: 1994
Standard clear opening dimensions : a x b (in cm)
For other clear opening dimensions, please consult us Norinco’s reference : ER3R (a x b) in cm
*Clear opening is reduced of 10 cm between boxes
2 covers 3 covers 4 covers 5 covers Removable
1 beam 2 beams 3 beams 4 beams beam

b clear used

137
152
167
182
197

214
229
244
259
274
289
304

291
306
321
336
351
366
381
396
411

368
383
398
413
428
443
458
473
488
503
518
opening
a (cm) (mm)

122 HEB200
2 137 h = 315
To 4th beam centre 152
covers
167
To 3rd beam centre
182
To 2nd beam centre
Recommended rebate 184
To 1st beam centre 199 1990
214 HEB220
3
229 h = 335
covers
244
259 HEB240
274 h = 335

Leveling bolts 246 HEB220


HEB240
261 h = 355
Leveling bolts
276
4 291
3660
covers 306
321 HEB260
h’= h+40 336 h = 375
351 3660
366
H= h’+35 Overall dimensions of cover (a+280mm) x (b+200mm) x (beam box height 400mm)

BEAM MULTIPLE COVERS


Beam centres (see section opposite)

137
152
167
182
197

214
229
244
259
274
289
304

291
306
321
336
351
366
381
396
411

368
383
398
413
428
443
458
473
488
503
518
2225 1455 685
2375 1455 685

2525 1605 685

2525 1605 835

2675 1755 835

2825 1755 835

2975 1905 835

2975 1905 985

3125 2055 985


1455 685
1605 685
1605 835

1755 835

1905 835

1905 985

2055 985
685
685
835
835
985

2995 2225 1455 685

3145 2375 1455 685


3295 2375 1605 685

3295 2525 1605 835


3445 2525 1755 835

3595 2675 1755 835

3745 2825 1755 835

3895 2825 1905 835

3895 2975 1905 985

4045 2975 2055 985

4195 3125 2055 985


W
Leveling bolts
Beam
X To 2nd beam centre
centres
Y To 3rd beam centre
Cover opening direction

(mm)

Z To 4th beam centre


Removable beam

Lifting Locking option Drawings


Pair of EM keys (weight 8 kg/pair) (composed of 4 stainless steel bolts) Layout drawings are available showing the
see details on p. 85 Standard locking (VCHC) cover/frame and the concrete rebate
or security locking (VOTC) dimensions. Please consult us.
Add suffix to
reference.
Adjusting bolts
50 135
80
max.
In order to facilitate the For example :
levelling of ERMATIC® ER3R (a x b) VCHC Installation
systems,adjusting bolts are (see detail on p. 3) see recommendations on p. 79
100
b supplied with the products.
Cover recessed for filling with 40 MPA concrete These bolts will allow, if Infilling of recessed covers
Dimensions in mm
See recommendations on P84 necessary, to adjust the height see recommendations on p. 84
of the system to the final
level and correct any How to specify
possible defects of the civil work. see detail on p. 88
62 63
ERMATIC® COVERS ERMATIC® COVERS
C250 C250
NORINCO NORINCO

Multiple covers with removable beams


Solid top cover with anti-slip surface
Specification Place of installation
• ERMATIC® C 250 multiple • Ductile cast iron according Parking and yard
access covers with removable to ISO 1083 and EN 1563 areas for all types of
beams • Galvanised mild steel beams road vehicles, fore-
• Solid top covers with anti-slip • Quality assurance by third C250 courts and service
surface party certification to areas.
• Clear opening (a x b) in mm ISO 9001: 2000
Reference ER3S (a x b) in cm
• Machined horizontal and
vertical contact faces Group 3 and lower
As per EN124: 1994
Standard clear opening dimensions : a x b (in cm)
for other clear opening dimensions, please consult us
*Clear opening is reduced of 10 cm between boxes Norinco’s reference : ER3S (a x b) in cm

2 covers 3 covers 4 covers 5 covers Removable


1 beam 2 beams 3 beams 4 beams beam

b clear used

137
152
167
182
197

214
229
244
259
274
289
304

291
306
321
336
351
366
381
396
411

368
383
398
413
428
443
458
473
488
503
518
opening
a (cm) (mm)

to 4th beam centre 122 HEB200


137 h = 315
to 3rd beam centre 2
152
covers
Recommended rebate to 2nd beam centre 167
182
to 1st beam centre
184
199 1990
214 HEB220
3
229 h = 335
covers
244
259 HEB240
274

h’= h+40 246 HEB220


261 HEB240

276 h = 355
Leveling bolts H= h’+35
291 3660
4
covers 306
321 HEB260
336 h = 375
351 3660
366
Leveling bolts Overall dimensions of cover (a+280mm) x (b+200mm) x (beam box height : h’)

BEAM MULTIPLE COVERS


Beam centres (see section opposite)

137
152
167
182
197

214
229
244
259
274
289
304

291
306
321
336
351
366
381
396
411

368
383
398
413
428
443
458
473
488
503
518
Clear opening in cm

2225 1455 685


2375 1455 685
2525 1605 685

2525 1605 835

2675 1755 835

2825 1755 835

2975 1905 835

2975 1905 985

3125 2055 985


1455 685
1605 685

1605 835

1755 835

1905 835

1905 985

2055 985
685
685

835

835
985

2995 2225 1455 685

3145 2375 1455 685

3295 2375 1605 685


3295 2525 1605 835

3445 2525 1755 835

3595 2675 1755 835

3745 2825 1755 835

3895 2825 1905 835

3895 2975 1905 985

4045 2975 2055 985

4195 3125 2055 985


W
Beam
Removable beam

X To 2nd beam centre


centres
Cover opening direction

(mm) Y To 3rd beam centre


Leveling bolts
Z To 4th beam centre

Lifting Locking option Drawings


Pair of EM keys (weight 8 kg/pair) (composed of 4 stainless steel bolts) Layout drawings are available showing the
see details on p. 85 Standard locking (VCHC) cover/frame and the concrete rebate
or security locking (VOTC) dimensions. Please consult us.
Add suffix to
reference.
Adjusting bolts
In order to facilitate the For example :
levelling of ERMATIC® ER3S (a x b) VCHC
systems,adjusting bolts are Installation
(see detail p. 3) see recommendations on p. 79
Solid top cover with anti-slip surface supplied with the products.
These bolts will allow, if
Dimensions in mm
necessary, to adjust the height
of the system to the final How to specify
level and correct any see detail on p. 88
possible defects of the civil work.
64 65
ERMATIC® COVERS ERMATIC® COVERS
D400 D400
NORINCO NORINCO

Multiple covers with removable beams


Covers recessed for concrete infill
Specification Place of installation

• ERMATIC® D 400 multiple • Ductile cast iron according Carriageways of roads


access covers with removable to ISO 1083 and EN 1563 (including pedestrian
beams • Galvanised mild steel beams steets),
• Covers recessed for concrete • Quality assurance by third D400 hard shoulders and
infill party certification to parking areas for all
• Clear opening (a x b) in mm ISO 9001: 2000 types of road vehicles.
Reference ER5R (a x b) in cm
• Machined horizontal and
vertical contact faces
Group 4 and lower
As per EN124: 1994

Standard clear opening dimensions : a x b (in cm) Norinco’s reference : ER5R (a x b) in cm


for other clear opening dimensions, please consult us
2 covers 3 covers 4 covers 5 covers Removable
1 beam 2 beams 3 beams 4 beams beam

Z to 4th beam centre b clear used

137
152
167
182
197

214
229
244
259
274
289
304

291
306
321
336
351
366
381
396
411

368
383
398
413
428
443
458
473
488
503
518
opening
Y to 3rd beam centre a (cm) (mm)

X to 2nd beam centre 122 IPE360


W to 1st beam centre 137 (h = 470)
Recommended rebate 2
152
covers
167
170 170 182
184
199
250 250 214
3
229
Leveling bolts covers
244
259
274

246
450
261
h+70

276
4 291 2910
b covers 306
IPE400
321 (h = 510)
336
351
250

BEAM MULTIPLE COVERS


366 3660
Overall dimensions of cover (a+360mm) x (b+220mm) x (beam box height = h +30mm)
Beam centres (see section opposite)

137
152
167
182
197

214
229
244
259
274
289
304

291
306
321
336
351
366
381
396
411

368
383
398
413
428
443
458
473
488
503
518
Clear opening in cm
h

2225 1455 685


2375 1455 685

2525 1605 685

2525 1605 835

2675 1755 835

2825 1755 835

2975 1905 835

2975 1905 985

3125 2055 985


1455 685
1605 685
1605 835

1755 835

1905 835

1905 985

2055 985
685

685
835

835

985

2995 2225 1455 685

3145 2375 1455 685

3295 2375 1605 685

3295 2525 1605 835


3445 2525 1755 835

3595 2675 1755 835

3745 2825 1755 835

3895 2825 1905 835

3895 2975 1905 985

4045 2975 2055 985

4195 3125 2055 985


W
Cover opening direction

Beam
X To 2nd beam centre
centres
Removable beam

(mm) Y To 3rd beam centre


h
h+30 mm
Z To 4th beam centre
a

Lifting Locking Drawings


180 a Pair of EM keys (weight 8 kg/pair) (composed of 4 stainless steel bolts) Layout drawings are available showing the
see details on p. 85 cover/frame and the
Standard locking (VCHC) concrete rebate dimensions.
or security locking (OTC) Please consult us.
Add suffix to
reference
80 150 Adjusting bolts
250

150 max.
In order to facilitate the For example : Installation
levelling of ERMATIC® ER5R (a)(b) VOTC see recommendations on p. 79
110
b systems,adjusting bolts are (see detail on p. 3)
Cover recessed for filling with 40 MPA concrete supplied with the products.
Dimensions in mm See recommendations on p. 84 Infilling of recessed covers
h+70

These bolts will allow, if


see recommendations on p. 84
necessary, to adjust the height
of the system to the final How to specify
level and correct any see detail on p. 88
66 possible defects of the civil work. 67
ERMATIC® COVERS ERMATIC® COVERS
D400 D400
NORINCO NORINCO

Multiple covers with removable beams


Solid top cover with anti-slip surface
Specification Place of installation
• ERMATIC® D 400 multiple • Ductile cast iron according Carriageways of
access covers with removable to ISO 1083 and EN 1563 roads (including
beams • Beam(s) galvanised mild steel pedestrian steets),
• Solid top cover with anti-slip • Quality assurance by third D400 hard shoulders and
surface party certification to parking areas for all
• Clear opening (a x b) in mm ISO 9001: 2000 types of road vehicles
reference ER5S (a x b) in cm
• Machined horizontal and
vertical contact faces
Group 4 and lower
As per EN124: 1994

Standard clear opening dimensions : a x b (in cm) Norinco’s reference ER5S (a x b) in cm


for other clear opening dimensions, please consult us
2 covers 3 covers 4 covers 5 covers Removable
1 beam 2 beams 3 beams 4 beams beam

b clear used

137
152
167
182
197

214
229
244
259
274
289
304

291
306
321
336
351
366
381
396
411

368
383
398
413
428
443
458
473
488
503
518
Z To 4th beam centre opening
a (cm) (mm)
Y To 3rd beam centre
122 IPE360
Recommended rebate X To 2nd beam centre 137
2 (h = 470)
W To 1st beam centre 152
covers
167
170 182
170
184
199
250 214
3
250 229
covers
244
Leveling bolts
259
274
450 246
261
b 276
4 291 2910
covers 306
h+70

IPE400
321 (h = 510)
336
351

BEAM MULTIPLE COVERS


366 3660
250

Overall dimensions of cover (a+360mm) x (b+220mm) x (beam box height = h +30mm)


Beam centres (see section opposite)

137
152
167
182
197

214
229
244
259
274
289
304

291
306
321
336
351
366
381
396
411

368
383
398
413
428
443
458
473
488
503
518
Clear opening in cm

2225 1455 685


2375 1455 685

2525 1605 685

2525 1605 835

2675 1755 835

2825 1755 835

2975 1905 835

2975 1905 985

3125 2055 985


1455 685

1605 685

1605 835

1755 835

1905 835

1905 985

2055 985
685

685
835

835

985

2995 2225 1455 685

3145 2375 1455 685

3295 2375 1605 685

3295 2525 1605 835


3445 2525 1755 835

3595 2675 1755 835

3745 2825 1755 835

3895 2825 1905 835

3895 2975 1905 985

4045 2975 2055 985

4195 3125 2055 985


W
h

Beam
Cover opening direction

X To 2nd beam centre


centres
(mm) Y To 3rd beam centre
Removable beam

h
h+30 mm
Z To 4th beam centre
a

Lifting Locking Drawings


180 a Pair of EM keys (weight 8 kg/pair) (composed of 4 stainless steel bolts) Layout drawings are available showing the
see details on p. 85 cover/frame and the
Standard locking (VCHC) or security locking
concrete rebate dimensions.
(OTC) add suffix
Please consult us.
to reference
150 160 max.
For example :
Adjusting bolts
ER5S (a x b) VOTC
250

110 b In order to facilitate the (see detail on p. 3)


levelling of ERMATIC® Installation:
systems,adjusting bolts are see recommendations on p. 79
Solid top cover with anti-slip surface
supplied with the products.
Dimensions in mm These bolts will allow, if
h+70

necessary, to adjust the height How to specify:


of the system to the final
see detail on p. 88
level and correct any
68 possible defects of the civil work. 69
ERMATIC® COVERS ERMATIC® COVERS
E600 E600
NORINCO NORINCO

Multiple covers with removable beams


Covers recessed for concrete infill
Specification Place of installation

• ERMATIC® E 600 multiple • Ductile cast iron according Areas imposing high
access covers with removable to ISO 1083 and EN 1563 wheel loads e.g.
beams •Galvanised mild steel Beams docks, aircraft
• Covers recessed for concrete • Quality assurance by third E600 pavements.
infill party certification to
• Clear opening (a x b) in mm ISO 9001: 2000
Reference ER6R (a x b) in cm
• Machined horizontal and Group 5 and lower
vertical contact faces
As per EN124: 1994

Standard clear opening dimensions : a x b (in cm) Référence NORINCO : ER6R (a en cm)(b en cm)
For other clear opening dimensions, please consult us
2 covers 3 covers 4 covers 5 covers Removable
I beam 2 beams 3 beams 4 beams beam
clear used
b

137
152
167
182
197

214
229
244
259
274
289
304

291
306
321
336
351
366
381
396
411

368
383
398
413
428
443
458
473
488
503
518
opening
Z To 4th beam centre a (cm) (mm)
Y To 3rd beam centre
122 IPE360
X To 2nd beam centre 137 (h = 470)
2
Recommended rebate W To 1st beam centre 152
covers
167
182
170 170 1840
184
199 IPE400
214 (h = 510)
3
250 250 229
covers 2440
244
259 IPE450
274 (h = 560)

246 IPE400

450 261 IPE450


(h = 560)
276
h+70

4 291 IPE500
306 (h = 610)
covers
b 321
336 3360
351 IPE550
366 (h = 660)
250

BEAM MULTIPLE COVERS


Overall dimensions of cover (a+360mm) x (b+220mm) x (beam box height = h +30mm
Beam centres (see section opposite)

137
152
167
182
197

214
229
244
259
274
289
304

291
306
321
336
351
366
381
396
411

368
383
398
413
428
443
458
473
488
503
518
2225 1455 685
2375 1455 685

2525 1605 685

2525 1605 835

2675 1755 835

2825 1755 835

2975 1905 835

2975 1905 985

3125 2055 985


1455 685

1605 685

1605 835

1755 835

1905 835

1905 985

2055 985
685

685
835

835

985

2995 2225 1455 685

3145 2375 1455 685

3295 2375 1605 685

3295 2525 1605 835


3445 2525 1755 835

3595 2675 1755 835

3745 2825 1755 835

3895 2825 1905 835

3895 2975 1905 985

4045 2975 2055 985

4195 3125 2055 985


W
h

Beam
Cover opening direction

X To 2nd beam centre


centres
(mm) Y To 3rd beam centre
Removable beam

h Z To 4th beam centre


h+30 mm
a

Lifting Locking option recommended Drawings


180 a Pair of EM keys (weight 8 kg/pair) (composed of 4 stainless steel bolts) Layout drawings are available showing the
see details on p. 85 cover/frame and the
Standard locking (VCHC)
concrete rebate dimensions.
or security locking (VOTC)
Please consult us.
Add suffix to
reference.
80 150 Adjusting bolts
For example :
250

150 max.
In order to facilitate the ER6R (a x b) VCHC Installation
levelling of ERMATIC® see recommendations on p. 79
110 (see detail on p. 3)
b systems,adjusting bolts are
Cover recessed for filling with 40 MPA concrete
supplied with the products. Infilling of recessed covers
Dimensions in mm See recommendations on p. 84
h+70

These bolts will allow, if


see recommendations on p. 84
necessary, to adjust the height
of the system to the final How to specify
level and correct any see detail on p. 88
70 possible defects of the civil work. 71
ERMATIC® COVERS ERMATIC® COVERS
E600 E600
NORINCO NORINCO

Multiple covers with removable beams


Solid top cover with anti-slip surface
Specification Place of installation
• Ermatic® E 600 multiple • Ductile cast iron according Areas imposing high
access covers with removable to ISO 1083 and EN 1563 wheel loads e.g.
beams • Beam(s) galvanised mild steel docks, aircraft
• Solid top cover with anti-slip • Quality assurance by third E600 pavements.
surface party certification to
• Clear opening (a x b) in mm ISO 9001: 2000
Reference ER6S (a x b) in cm
• Machined horizontal and
vertical contact faces Group 5 and lower
As per EN124: 1994

Standard clear opening dimensions : a x b (in cm) Norinco’s reference : ER6S (a x b) in cm


For other clear opening dimensions, please consult us
2 covers 3 covers 4 covers 5 covers Removable
1 beam 2 beams 3 beams 4 beams beam

b clear used

137
152
167
182
197

214
229
244
259
274
289
304

291
306
321
336
351
366
381
396
411

368
383
398
413
428
443
458
473
488
503
518
opening
a (cm) (mm)
Z to 4th beam centre
Y to 3rd beam centre 122 IPE360
137 (h = 470)
X to 2nd beam centre 2
Recommended rebate 152
covers
W to 1st beam centre 167
182
170 170 184 1840
199 IPE400
214 (h = 510)
250 3
229
covers 2440
250 244
Leveling bolts 259 IPE450
274 (h = 560)

246 IPE400
450
261 IPE450
(h = 560)
276
b 291
4 IPE500
couvercles 306 (h = 610)
321
h+70

336 3360
351 IPE550
366 (h = 660)

BEAM MULTIPLE COVERS


Overall dimensions of cover (a+360mm) x (b+220mm) x (beam box height = h +30mm)
250

Beam centres (see section opposite)

137
152
167
182
197

214
229
244
259
274
289
304

291
306
321
336
351
366
381
396
411

368
383
398
413
428
443
458
473
488
503
518
Clear opening in cm

2225 1455 685


2375 1455 685

2525 1605 685

2525 1605 835

2675 1755 835

2825 1755 835

2975 1905 835

2975 1905 985

3125 2055 985


1455 685

1605 685

1605 835

1755 835

1905 835

1905 985

2055 985
685

685
835

835

985

2995 2225 1455 685

3145 2375 1455 685

3295 2375 1605 685

3295 2525 1605 835


3445 2525 1755 835

3595 2675 1755 835

3745 2825 1755 835

3895 2825 1905 835

3895 2975 1905 985

4045 2975 2055 985

4195 3125 2055 985


W
h

Beam
X To 2nd beam centre
centres
Cover opening direction

(mm) Y To 3rd beam centre


Removable beam

h Z To 4th beam centre


h+30 mm
a

Lifting Locking option recommended Drawings


180 a Pair of EM keys (weight 8 kg/pair) (composed of 4 stainless steel bolts) Layout drawings are available showing the
see details on p. 85 cover/frame and the
Standard locking (VCHC) concrete rebate dimensions.
or security locking (VOTC) Please consult us.
Add suffix to
150 160 max.
reference.
Adjusting bolts
250

110 b In order to facilitate the


levelling of ERMATIC® Installation
systems,adjusting bolts are For example : see recommendations on p. 79
Solid top cover with anti-slip surface ER6S (a x b) VCHC
supplied with the products.
Dimensions in mm These bolts will allow, if (see detail on p. 3)
h+70

necessary, to adjust the height How to specify


of the system to the final see detail on p. 88
level and correct any
72 possible defects of the civil work. 73
ERMATIC® COVERS ERMATIC® COVERS
F900 F900
NORINCO NORINCO

Multiple covers with removable beams


Covers recessed for concrete infill
Specification Place of installation

• ERMATIC® F 900 multiple • Ductile cast iron according Areas imposing


access covers with removable to ISO 1083 and EN 1563 particularly high
beams • Galvanised mild steel Beams wheel loads e.g.
• Covers recessed for concrete • Quality assurance by third F900 docks, aircraft
infill party certification to pavements.
Filled cover
• Clear opening (a x b) in mm ISO 9001: 2000
Reference ER9R (a x b) in cm
• Machined horizontal and
vertical contact faces Group 6 and lower
As per EN124: 1994

Standard clear opening dimensions : a x b (in cm) Norinco’s reference : ER9R (a x b) in cm


For other clear opening dimensions, please consult us
2 covers 3 covers 4 covers 5 covers Removable
1 beam 2 beams 3 beams 4 beams beam
clear used
b

137
152
167
182
197

214
229
244
259
274
289
304

291
306
321
336
351
366
381
396
411

368
383
398
413
428
443
458
473
488
503
518
Z to 4th beam centre opening
a (cm)
(mm)
Y to 3rd beam centre
122 IPE360
X to 2nd beam centre
137 (h = 470)
W to 1st beam centre 2
Recommended rebate 152
covers
167
182
170 170
184 1840
199 IPE400
(h = 510)
214
250 250 3
covers 229
Leveling bolts 2440
244
259 IPE450
274 (h = 560)

IPE400
246
450 261 IPE450
(h = 560)
276
h+70

291 IPE500
4 (h = 610)
306
b covers
321
336 3360
351 IPE550
250

366 (h = 660)

BEAM MULTIPLE COVERS


Overall dimensions of cover (a+360mm) x (b+220mm) x (beam box height = h +30mm)
Beam centres (see section opposite)

137
152
167
182
197

214
229
244
259
274
289
304

291
306
321
336
351
366
381
396
411

368
383
398
413
428
443
458
473
488
503
518
Clear opening in cm

2225 1455 685


2375 1455 685

2525 1605 685

2525 1605 835

2675 1755 835

2825 1755 835

2975 1905 835

2975 1905 985

3125 2055 985


1455 685
1605 685

1605 835

1755 835

1905 835

1905 985

2055 985
685
685
835
835
985

2995 2225 1455 685


3145 2375 1455 685
3295 2375 1605 685
3295 2525 1605 835
3445 2525 1755 835

3595 2675 1755 835

3745 2825 1755 835

3895 2825 1905 835

3895 2975 1905 985

4045 2975 2055 985

4195 3125 2055 985


h

W
Beam
Cover opening direction

X To 2nd beam centre


centres
To 3rd beam centre
Removable beam

(mm) Y
h
h+30 mm Z To 4th beam centre
a

Lifting Locking option recommended Drawings


180 a Pair of EM keys (weight 8 kg/pair) (composed of 4 stainless steel bolts) Layout drawings are available showing the
see details on p. 85 cover/frame and the
Standard locking (VCHC)
concrete rebate dimensions.
or security locking (VOTC)
Please consult us.
Add suffix to
reference.
80 150 Adjusting bolts
250

150 max.
In order to facilitate the For example : Installation
levelling of ERMATIC® see recommendations on p. 79
110
systems,adjusting bolts are
ER9R (a x b) VCHC
b
Cover recessed for filling with 40 MPA concrete
supplied with the products. (see detail on p.3)
Dimensions en mm See recommendations on p. 84 Infilling of recessed covers
h+70

These bolts will allow, if


see recommendations on p. 84
necessary, to adjust the height
of the system to the final How to specify
level and correct any see detail on p. 88
74 possible defects of the civil work. 75
DISPOSITIF
ERMATIC® ERMATIC
COVERS DISPOSITIF
ERMATIC® ERMATIC
COVERS
D
F900
400 DF400
900
NORINCO NORINCO

Multiple covers with removable beams


Solid top cover with anti-slip surface
Specification Place of installation
• ERMATIC F 900 multiple • Ductile cast iron according Areas imposing
access covers with removable to ISO 1083 and EN 1563 particularly high
beams • Beam(s) galvanised mild steel wheel loads e.g.
• Solid top cover with anti-slip • Quality assurance by third F900 docks, aircraft
surface party certification to pavements.
• Clear opening (a x b) in mm ISO 9001: 2000
Reference ER9S (a x b) in cm
• Machined horizontal and
vertical contact faces Group 6 and lower
As per EN124: 1994
Group 6 and lower
As per EN124: 1994
Standard clear opening dimensions : a x b (in cm Norinco’s reference : ER9S (a x b) in cm
For other clear opening dimensions, please consult us
2 covers 3 covers 4 covers 5 covers Removable
I beam 2 beams 3 beams 4 beams beam
clear used
b

137
152
167
182
197

214
229
244
259
274
289
304

291
306
321
336
351
366
381
396
411

368
383
398
413
428
443
458
473
488
503
518
Z to 4th beam centre opening
a (cm)
(mm)
Y to 3rd beam centre clear

X to 2nd beam centre 122 opening IPE360


(cm)
2 137 (h = 470)
Recommended rebate W to 1st beam centre 152
covers
2 167
170 covers182
170
184 1840
199 IPE400
(h = 510)
250 214
3
250 covers 229
Leveling bolts 2440
244
3 IPE450
covers259 (h = 560)
274
IPE400
450 246
261 IPE450
(h = 560)
b 276
4 291 IPE500
covers 306 (h = 610)
h+70

4 321
3360
covers336
351 IPE550
366 (h = 660)

BEAM MULTIPLE COVERS


Overall dimensions of cover (a+360mm) x (b+220mm) x (beam box height = h +30mm
250

Beam centres (see section opposite)


Overall dimensions of cover (a+360mm) x (b+220mm) x (beam box height = h +30mm

137
152
167
182
197

214
229
244
259
274
289
304

291
306
321
336
351
366
381
396
411

368
383
398
413
428
443
458
473
488
503
518
Clear opening in cm

2225 1455 685


2375 1455 685
2525 1605 685

2525 1605 835

2675 1755 835

2825 1755 835

2975 1905 835

2975 1905 985

3125 2055 985


1455 685

1605 685
1605 835

1755 835

1905 835

1905 985

2055 985
685

685
835

835

985

2995 2225 1455 685

3145 2375 1455 685


3295 2375 1605 685

3295 2525 1605 835


3445 2525 1755 835

3595 2675 1755 835

3745 2825 1755 835

3895 2825 1905 835

3895 2975 1905 985

4045 2975 2055 985

4195 3125 2055 985


W
h

Beam
Cover opening direction

X To 2nd beam centre


centres
Removable beam

(mm) Y To 3rd beam centre


h
h+30 mm Z To 4th beam centre
a

Lifting Locking option recommended Drawings


180 a Pair of EM keys (weight 8 kg/pair) (composed of 4 stainless steel bolts) Layout drawings are available showing the
see details on p. 85 cover/frame and the
Standard locking (VCHC)
concrete rebate dimensions.
or security locking (VOTC)
Please consult us.
Add suffix to
150 160 max. reference.
Adjusting bolts
250

110 b In order to facilitate the For example :


levelling of ERMATIC® Installation
systems,adjusting bolts are
ER9S (a x b) VCHC
see recommendations on p. 79
supplied with the products. (see detail on p.3)
Dimensions en mm Cover recessed for filling with 40 MPA concrete These bolts will allow, if
h+70

See recommendations on p. 84 necessary, to adjust the height How to specify


of the system to the final
see detail on p. 88
level and correct any
76 possible defects of the civil work. 77
INSTALLATION INSTALLATION
RECOMMENDATIONS RECOMMENDATIONS

There is no standard or definitive guide


to the installation of access covers and
frames. These recommendations are
Frame depth: 80mm Frame depth: 125mm
designed to assist in the installation of Rebate
ERMATIC® covers in general situations
that present no particular technical 100 80
1  For all Covers and frames,
125

150
difficulties. prepare a peripheral rebate
in accordance with the suggested
All frames and beam wallboxes must be clear dimensions.
opening
adequately, solidly and continuously axb
200
supported to a degree sufficient for the 200  For beamed multiples and special
designed load conditions in each particu- ducts with angles and returns, see
lar case. the specific details provided during
ERMATIC® covers and frames are made the design or accompanying
Frame depth: 150mm the delivery.
from machined elements, assembled to
strict tolerances.

170
The frames are assembled around 150
their respective covers so as to provide
a peripheral contact between
their seatings and side contact faces. 250
When correctly installed, maintaining
the tolerance imparted at the factory,


ERMATIC® ensure stability and sealing
against water and debris.
Installation and shuttering
In order to protect the machined
surfaces from contamination with silt See next page
and mud, cover and frame components


must be positioned or stored on clean
surfaces. Grouting
Important:  Force the grout beneath the frame.
The covers must be in their correct  Fill the rebate in successive layers.
position(s) within the frame (and loc-
NORFOND
PLAN

1/3

ked if applicable) whilst the frames  Do not forget to vibrate the grout.
PRODUKT ERMATICÆ ER5R199214VCHC Artikelnummer : 515075
"EM" Bedienungsschl¸ssel

are grouted in position.


Bestellung : 0 (2 Stk.)(nicht im Lieferumfang)

 If there is insufficient time to


Beschreibung : ERMATICÆ D400 Fl‰chenabdeckung zur bauseitigen Betonf¸llung verriegelt CHC
PRO
Bes DU
Gewicht : 1503 Kg tell KT
ung
: NO
0 ERM RFO
÷ffnungsrichtung ND
ATI

ER5
R19
921
4VC
HC

allow the concrete to fully cure


Art
ikel
num
me
r:
515
075 VER
MA
flUN
G
- Ang 2/3
600 600 600 250 - ƒnd abe
- Fre eru n zu
nge Gew
ie Ver

before trafficking, use a rapid


n icht
bre vorbeh , Grˆ
itun
E E E
g. alten. {fle sind
R
M
A R
M
A R
M
A
T
IC T
IC T
IC unv
erb
214 indl
0 ich.
600

A D G
ILS

setting grout such as EMACO


DETA
540

3/3

O O O O O O
E
R
M E
R
M E
R
M 450
A
T
IC A
T
IC h. A
T
IC
bindlic
unver
e sind
ht, Grˆ{fl
.
Gewic

T926 or similar.
en zu vorbehalten
600

- Angabungen
B
.
E H
- ƒnder Verbreitung
1990

OND - Freie
NORF 75
5150
er :
lnumm
HC Artike O O O O O O
14VC
1992 E E E
ER5R R
M
A R
M
A R
M
A
TICÆ vationT
I
C T
I
C T
I
C
ERMA reser
eral
Periph
UKT
PROD
750

C F I
0
:
170

llung
Beste
0

shims
ing steel
199

250

Levell
ering
cover Shutt
20

and
bar
frame
n on 500-7 ng
Sectio Grade O O O Openi O O O
63, Clear
/ EN15
540
70

1083
to ISO
SG Iron 170
R
COVE
80

2140
250
150

110
Clear
Openi
ng

TRAN
SVER
SE SECT
ION
ON BEAM

Frame
450

Shuttering
0
199

685
150

boxe
Wall
500

145
5
screw
Chc

TECHNICAL
steel Alle Grˆ{flenangaben in mm.
ess
L‰nge gesamt :
Stainl
2350 Rahmen und0DeckelAlle
IPE36 aus Guss
Grˆ

ASSISTANCE WITH INSTALLATION


key Beam
GS 500-7 gem‰{fl ISO 1083{fle
250

Chc Breite gesamt : 2360 nan


Ma gab
r flst en
washeErstellt von : ab: mm in
Maflstab : 1/ 20 steel at Datum : 14/04/2006
- Angaben zu. Gewicht, Grˆ{fle sind unverbindlich.
ess ing bolts 1/
Stainl
NORFOND LevellGmbH
Norinco Deutschland NO - ƒnderungen
25 vorbehalten.
Dieses Dokument ist Eigentum von Norfond und darf nicht ohne
Einemstrafle 5 RFO
ND - Freie Erlaubnis
Verbreitung.
weitergegeben oder vervielf‰ltigt werden.
GROUPE NORINCO D-10787 Berlin GROU
www.norinco.fr Tel. +49-30-200 51-0 Fax +49-30-200 51-299 PE Ers
tell
ww
w.n NORIN t von
r orin 360CO :
washe co. Norin
rene fr co
Deut at
Neop Einem schla
Tel. D-10787strafl nd
Fax +49-3 e 5 GmbH
norin +49-3 0-20 Berlin Dat
co@n 0-20 0
orinc 0 51-0
um
o-ger 51-2 : 14/
many99
.com 04/
200
6

For the installation of access covers and frames, Norinco


boxes Die
and nich
beam ses
500

n on t ohn Dok
tudina
l sectio e Erla ument
ubn
is wei ist Eig
Longi

ter ent
geg um
ebe von
n ode Norfon
470


r ver d
viel und dar
f‰

can provide, upon demand various levels of technical


ltig f
t wer
den
0 .
IPE36
E BEAM
VABL
REMO
170

nd und n.

assitance.
Filling covers (Recessed series)
ng von
Norfo gt werde
Openi tum lf‰lti
Clear vervie
ist Eigen oder
06 ent ben
4/20 s Dokum weitergege
14/0 Diese nis
:
Datum Erlaub
ohne
nicht
darf
at
:
170 llt von d GmbH
Erste chlan 5 9
e
co Deutsstrafl 51-29
Norin Einem 87 Berlin 0-200
D-107 Fax +49-3ny.com
51-0 germa
0-200 rinco-
OND +49-3norinco@no
NORF CO Tel.
PE NORIN o.fr
GROU norinc
www.

OBJECTIVE OF THE ASSISTANCE Please see instructions for infilling recessed covers on p.
84
 To assist the contractor in the installation and grouting of the


covers and frames to maintain the tolerances imparted at the
factory to guarantee the performance and stability Finition et mise en service
characteristics.
Companies responsible for access cover ins-  Allow the grout and concrete to  Clean and grease all the contact
tallation can amend or improve upon  To furnish the contractor with all information necessary to fully cure. faces of the cover and frame
Norinco's recommendations. Take out the covers and point each time the cover is opened.
operate and maintain the covers and frame.
Norinco reminds installers that these recom- the mortar joints Use a graphite grease. Norinco

TECHNICAL FILE
mendations are only indicative and Norinco EXAMPLES OF ASSISTANCE recommends ELF CARDREXA
accepts no liability for the installation
GEP 2.
of covers and frames.  Advice regarding installation.
 Technical assistance and training on site.
 Supervision of the complete installation including grouting.
78 79
INSTALLATION INSTALLATION
RECOMMENDATIONS RECOMMENDATIONS

 Installation and shuttering


1/2/3 - part covers and frames Covers and frames for ducts
 Correctly centre the cover and frame within  Position the first element 1 in the rebate in  Bolt the second element to the first .
the rebate accordance with the assembly drawing. Do not
 Complete the installation by repeating
cut the metal bands connecting the covers with
 Shim to the correct level (), at each frame the previous instructions and proceed element
the frames.
corner, and underneath each frame joint using by element.
metal (or similar) packers.  Centre and correctly level () by inserting metal
 Finish the installation with the generic Ermatic®
(or similar) shims beneath each frame corner
process, elements by elements, after removal of
and frame joint.
metal bands and covers.
 Position the second element 2  in the rebate.
 Centre and correctly level () the second element
by inserting metal (or similar) shims beneath each
frame angle and frame joint.

()

0,00 Shim to correct level 0,00


Centre


Shims

 Shutter Marks  Position the covers within  Mask the key


(A) (A)
the gap between their respective frames. wayswith the plas
the bottom of the If applicable, refer to the tic plugs.
frame and assembly drawing.
the concrete of the
 Check that covers do not
chamber. And, if applicable, fit
rock, and covers are in conti-
the oval plastic plugs in the bottom
 Check that the nuous contact with the
 Tighten the locking bolts of the covers (recessed covers only)
machined faces of frames. If necessary, adjust
the cover and the shims and use clamps to (if applicable) or the installa-
frame are free from obtain the correct condition. tion screws (if fitted)

TECHNICAL FILE
silt or mud. Clean
if neccessary.

80 81
INSTALLATION INSTALLATION
RECOMMENDATIONS RECOMMENDATIONS

 Installation and shuttering


Beamed multiple covers for large chambers
Class B125/C250 access covers : with the beam box leveling bolts. Class D400/E600/F900 access covers :
 Correctly position the frame elements  Insert shims (metal or similar) beneath each  Commence the assembly from one end of the  Check to ensure that the frame assembly
in the rebate in accordance with frame joint to correctly level () the frame. chamber in accordance with the assembly drawing. is centered within the chamber .
the assembly drawing.  Install and correctly centre the 1st beam (still  Shim to the correct level, () underneath each
 Tighten the bolts . bolted to the wallboxes) within the rebate. frame corner and underneath each frame joint
 Centre () the frame correctly within the rebate.  Correctly level the beam by adjusting the beam using metal (or similar) packers.
 Position the beam box leveling bolts to permit leveling bolts.   Complete (if necessary) the installation of the next
adequate adjustment. Place shims beneath each  Install and bolt to the wallbox, the adjacent beams and frame elements by repeating the
bolt and at each frame corner to correctly level end bars.  following 3 operations :
the frame corners .  Bolt the side frame bars (parallel to te beam)  Install and centre correctly within the rebate, the
 Check and adjust the alignment to the end bars.  2nd, 3rd beam etc. (still bolted to the wallboxes). 
of the beam boxes.  Correctly level the beam by adjusting the beam
leveling bolts. 
 Position the beams  in accordance with the
assembly drawing within
  Bolt to the corresponding end bars.
the beam boxes and check that the
top of the beams are in metal to metal contact with
  Install by bolting the 2 new end bars.
 Finish and close the construction of the frame by
the beam boxes.
bolting to the end bars,
 the side frame bars
 Check the level of the top of the beam and adjust (parallel to the beam)


()  

0,00 Shim to correct level 0,00


Centre

Shims




 Shutter (A)
Marks
(A)
 Position the covers within  Mask the key
the gap between their respective frames. wayswith the plas
the bottom of the If applicable, refer to the tic plugs.
frame and assembly drawing.
the concrete of the
 Check that covers do not
chamber. And, if applicable, fit
rock, and covers are in conti-
the oval plastic plugs in the bottom
 Check that the nuous contact with the
 Tighten the locking bolts of the covers (recessed covers only)
machined faces of frames. If necessary, adjust
the cover and the shims and use clamps to (if applicable) or the installa-
frame are free from obtain the correct condition. tion screws (if fitted)

TECHNICAL FILE
silt or mud. Clean
if neccessary. 

82 83
CONCRETE INFILL OF COVERS OPERATION OF ERMATIC®
COVERS

 Recommendations
In this document, the recommendations are given
in good faith and reflect the latest research ;
III) - INSTALLATION DIRECTION OF OPENING
nevertheless, we cannot accept any liability from Temperature of the concrete at the time of delivery : Covers can only be opened in one direction, indicated by Covers with locking bolts
their adoption. - between 10 and 32°C.
an arrow as shown below. • Note the position of the covers in the frame,
The description and choice of products must be • Remove the plastic keyhole caps. they are not interchangeable.
adequate with the specific conditions of each Temperature of the support : • Unscrew the locking bolts with :
application (conditions of use and installation). - Except special requirements, concreting must not be carried - For CHC : a six sided spanner.
out on supports :
- For OTC : a special OTC spanner. Note that the OTC
The covers' concrete infill is part of the complete pro- * of which the temperature is < 5°C, or
* of which the temperature varies by more than 10°C from bolt is left hand thread.
duct, so a particular care should be taken regarding
the temperature of the concrete.
its manufacture and application.
INTERCHANGEABILITY OF COVERS
The expected quality shall be the same as required
1/2/3 part covers and frames not locked
for construction work concrete with high mechanical
performances (> 40 Mpa after 28 days on a test The covers are interchangeable within the original frames.
Vibrating :
cylinder of 150 x 300 mm). 1/2/3 part covers and frames locked
- After filling, the concrete must be vibrated, preferrably
Therefore its composition shall be studied to achieve Duct covers (< 3 covers long)
on a vibration table. In case of vibration needles (pervibrators),
the highest possible performance with regard to the Beamed multiples
the "picking" must be done regularly on the cover surface while
specific concreting conditions of this application. avoiding any contact with the cast iron. The covers are not interchangeable. They have to be replaced in
- The vibration should obtain a maximum compacity and a perfect accordance with the marking system visibly stamped into each
filling of the recesses, without causing any segregation. cover and frame at the works.
I) - SUPPORT

The recesses must be clean, exempt from any trace of products Finishing :
such as grease, oil, sand, dust .... Any non adhesive particles - The filling must be carried out without excess
must be removed. - Flatness must be assured and checked by means COVER HANDLING
of a straight-edge. The maximum oscillation allowed is 3 mm. • To handle the covers, use a pair of EM keys with the
- The obtained surface must be equivalent to that blocking and jacking bolts.
II) - COMPOSITION OF THE CONCRETE
of the carriageway's surface. CLOSING
OPENING Before closing :
As an indication, the "typical concrete mix design"
may be characterized by : IV) – CURING OF CONCRETE • Clean the keyways with a • Clean and grease the machined faces
screwdriver of the cover and frame.
Cement Immediately after manufacturing and cuffing the free surface, B
- a cement CEM I or II 52,2 proportion near to 450 kg/m3. the latter must be protected from free circulation of air and from the opening direction is • If necessary, withdraw the jacking bolt from
- its chemical composition shall be adapted to the covers' any evaporation / desiccation. indicated with an arrow. the EM key so that it does not protrude. (B)
environment, e.g. cement type PM (marine and chloride This can be achieved : A
• Completely insert Position the covers in place
environments) for works exposed to a sea atmosphere. - Either by storing the covers in a place where the atmosphere
the EM keys. respecting (if appropriate) the marking system
has a humidity ratio near to 95 %.
Granulates visibly stamped into each cover and frame.
- Either by pulverizing it with a curing compound of which the effi- • Tighten the blocking
- A G/S (gravel / sand) ratio < 1,5.
- The diameter of the biggest granulate shall be < 12,5 mm.
ciency has been proved (re. list of approval and reference for the Replace the plastic keyhole caps.
execution of carriageways or airfield pavements in concrete). bolt (A) to lock the
- The required acceptance criteria must be those of construction
work concrete, of which the characterized resistance after key in position.
In case of concreting at low temperatures, every precaution
28 days is over 40 Mpa. • Tighten the jacking bolt (B)
must be taken to make sure that the temperature of the concrete
- If the granulates (or one of those) are (is) classified as potentially
remains above 5°C. to put tension on the cover/frame joint.
reactive (PR), then the total rate of active alkalines in the concrete
must be limited to a maximum of 3 kg/m3 (this requirement will • Apply downward pressure to the end of the EM
often lead to the choice of low alkali cement (< 0,6 %) ). V – RELEASE keys to assist leverage.
Water • Lift the one edge of the cover from the frame.
The works must only be released when the resistance of the
- The ratio of water / cement (W/C) must be smaller than 0,4. concrete infill will have attained 40MPa. • Pull the cover from the frame along the greased
- The water used must be drinking water. machined seatings.
Admixtures TECHNICAL ASSISTANCE - OTHER INFORMATION
- In order to reduce the W/C ratio and in respect to the
maintenance of the rheology for the time necessary to fill the For all precise information, please consult us. MAINTENANCE
several covers with concrete of the same batch, admixtures must
be certified to the NF Mark or complying with national standards
Before delivery, all the machined faces of the 1/2/3
(B.S./ASTM/AFNOR ...), such as plasticizers, High Range Water part cover and frame are greased (duct covers Characteristics of graphite grease :
Reducers, set retarding admixtures. The dosage of these and beamed multiples are greased by the contractor
• Resistance to loading and shock.
products (expressed as a percentage of the cement weight) must on site). Covers are partially painted with water soluble
be kept inside the limits defined by the supplier or in the product black paint. • Good adherence.
technical information sheet, in order to avoid detrimental effects • Insoluble in water.
In service, after each cover opening and when
on the other properties of concrete.
performance and environmental requirement demand, • Good resistance to extremes of temperature.
it is necessary to clean and apply and appropriate

TECHNICAL FILE
• Elf Cardrexa GEP 2 is recommended.
grease (see later) to the machined faces of the cover
and frame.

84 85
OTHER TECHNICAL SG CAST IRON
SOLUTIONS Please consult us

Multiple access covers and frame with removable beams


ERMATIC® covers and frame are manufactu-
SG cast iron covers / galvanised steel
frame
red from spheroïdal graphite cast iron accor-
Class B 125/C 250 ding to ISO 1083 and EN 1563 standards.
A material with remarkable characteristics
for RELIABLE and HIGH PERFORMING
access covers and frames.

What is SG cast iron ? SG cast iron compared to grey


Spheroïdal graphite cast iron is better known iron :
as ductile cast iron or SG cast iron. Due to the The exceptional ratio of weight/mechanical
addition of magnesium to the cast iron, the strength of SG cast iron allows the manufacture
graphite which is present in a flake form is of access covers with weights 20 to 30 % lower
transformed into spheroids. This process provides than the same access covers manufactured
remarkable features, such as resistance to in grey iron.
breakage, a better shock resistance and a high
Therefore, cost of transport can be reduced and
modulus of elasticity.
cover handling is achieved with lower risk of injury.
On the other hand, SG iron has excellent welding
properties. This allows the manufacture of long
sections, junctions or returns (which are not pos-
sible where products are manufactured from grey
iron).
Multiple access covers
and frame with removable beams

SG cast iron triangular


covers standard or hinged
and galvanised steel frame
Spheroïdal graphite
Class D 400 cast iron

Grey iron

Tensile strenth and elongation test pieces

TECHNICAL FILE
SG cast iron unit
with triangular hinged and lockable covers

86 87
SPECIFICATION DETAIL
FOR BILLS OF QUANTITY

Item Quantity Description Unit Total


price price

.................. ........ Ermatic® covers and frames :


Reference : ER ................. ............. .............

Clear opening dimensions :


(a x b in mm) : .......................

Mechanical characteristics :
Construction principles as per EN124: 1994 Class :
...................
(B 125, C 250, D 400, E 600, F 900)
(F 900 covers concreted for the recessed series)
• Beams :
(only applicable to beamed multiple units)
Conforming to the following French standards
ERMATIC® B 125 : Loading 500 daN/m2
ERMATIC® C 250 ; CCTG Chapter 61 clause II
ERMATIC® D 400 ; CCTG Chapter 61 clause II
ERMATIC® E 600 and F 900 : ADP and STBA

Covers :
• Type : ....................
(Recessed, solid top covers with anti-slip surface)
• Locking : ....................
(standard locking VCHC or security locking VOTC)
........ • OTC key for special security ........ ........
(Only when OTC is specified )

Material :
• Covers and frames :
SG cast iron according to ISO 1083 and EN 1563
• Beams and other steel components :
Conforming to NF EN 10025/34 - NFA45255/201/201
(Only for beamed multiples )

Cover stability :
Assured by machining the seating faces of the cover and frame.

Sealed against water and debris :


By the interposition of a film of grease (Cardrexa GEP2 by ELF) on the contact
faces of the cover and frame.

........ Pair of EM Keys for handling : ........ ........


By sliding on the machined faces of the cover and frame easily using a pair
of EM keys with blocking and jacking bolts.

Painting :
• Cast iron covers and frames :
Painted with water soluble paint except machined surfaces and surfaces
in contact with concrete
Covers supplied disassembled : Machined surfaces coated with a
protective film.
• Beams and other steel components :
Steel components protected by hot-dip galvanizing
to ISO 1461.

Installation, concrete filling of recessed covers and operation:


As per the manufacturer’s recommendations.

........ Technical assistance on site : ........ ........


Upon request from the manufacturer for large or complex covers.

Quality assurance/Certificate of conformity (on application) :


System of quality assurance conforms with the requirements of ISO 9001:
2000 certified by third party.

88

You might also like