Aculas®-HB-530

Cordless 2-channel LLLT System

(Auricular Application)
Performance & Safety Medical Laser Power Reliability
Innovative eartip laser The real laser power Equipped with the
Two laser beams emitted output (50 ~ 90 mW) per industrial grade
simultaneously channel laser diodes
Dispersion laser beam is CE Medical Verification Temp. rating 60°C
safer than any auricular GMP Quality MTBF (Mean Time
laser device in the market Certification Between Failures)
Cordless operation > 5,000 Hours

Efficacy -- The innovative eartip lasers emit to the right position.


Aculas-HB-530 is developed to apply Low Level Laser Treatment (LLLT) in
auricular regions for the achievement of "Laser Biostimulation" effect.

Aculas-HB-530 is patented and made using the combination of modern laser


diode technology, innovative optics design and computerized digital control.

Aculas-HB-530 is clinically proven for treatments as a mono therapy or as a


complementary treatment along with other therapies to treat:
Tinnitus
Meniere's disease
Hearing loss

Effective Specific laser power for the hearing diseases:


Specially designed laser beam evenly irradiates the inner
ear.
Advanced integrated circuit designed by Konftec with
automatic power control(APC) to maintain the specific
power output.
Industrial grade laser diodes with temperature rating of 60
°C and MTBF (Mean Time Between Failures) > 5,000
hours.
Safe Konftec's integrated circuit design for all laser modules
provide full protection of:
EDS (Electrostatic Discharge)
over-temperature
soft-start
Easy to Use Cordless operation powered by battery pack for hand free
and mobile treatment.
Powered by three rechargeable NiMH AAA batteries, which
can also be purchased from the local stores.
Dynamic blue LED display for clear reading.
To set the last therapy process with " Start " button.

Operation Environment 0 ~ 50 °C (32 ~ 122 °F); 10 ~ 95%RH (Non-condensing)


Storage Environment -20 ~ 85 °C (4 ~ 185 °F); 10 ~ 95%RH (Non-condensing)
Time Setting 1 ~ 60 Minutes (Min. Setting Segment 1 Minute)
Beeper Alert Setting and Stop
Power Supply 3 x Rechargeable NiMH Battery AAA
Controller Enclosure Color Black or White
Battery Charger / AC Power Supply Unit
Power Input Voltage 90V AC ~ 264V AC
Power Input Frequency 47Hz ~ 63Hz
Power Input Current Max. 0.5A (115V AC), 0.25A (230V AC)
Power Supply Protection Short Circuit and Overload; Auto Recovery Mode
EMC Directive 93/42/EEC
Verification (Operation Environment: Medical Electrical Equipment)
Standard Applied: IEC 60601-1 and EC 60601-1-2

Medical Device Certificate


GMP (Good Manufacturing Practice) ISO 13485
Shipping Dimensions 30(L) x 25(W) x 20(H) cm; 12(L) x 10(W) x 8(H) in
Shipping Weight 1.5 Kg (3.3 Lbs)
Auricular Laser Module LE-2
Quantity of Laser Module 2
Laser Material Semiconductor Laser Diode
660nm… AlGaInP
780nm… AlGaAs
Wavelength 660nm… 50mW
& Output Power 780nm… 90mW
Insert Eartip Material Rubber; Replaceable
Insert Eartip Size Selectable Diameter 4 ~ 16mm
Battery Charger / AC Power Supply Unit WP-191
Power Input Voltage 90V AC ~ 264V AC
Power Input Frequency 47Hz ~ 63Hz
Power Input Current Max. 0.5A (115V AC), 0.25A (230V AC)
Power Supply Protection Short Circuit and Overload; Auto Recovery Mode

Laser Module
Model No. Total
Aculas- LE-217A90 LE-216A50 Output Power
780nm @ 90mW 660nm @ 50mW
HB-530A 2 180mW
HB-530B 2 100mW

Therapy Time Frequency Session (Times)


Minutes Time/Day Avg. Max.
30 1 10 15
Remarks:
There is no laser leakage if the laser modules are properly applied. It is not necessary to
wear laser safety goggles.
Ten treatments are usually administered on either 10 consecutive days, or over a two
week period. It takes 1~3 months to see the effectiveness (after the treatment, it need
time for your body to repair yourself).
HB-530 is applying two ear tips and the laser beam is designed to be dispersion type,
with the beam divergence angles in parallel and perpendicular, you can just put it on and
move slightly- ideally applied for home therapy.
We recommend the application of HB-530A for the best effectiveness. Applying the
infrared laser is the most suitable laser for most sufferers.