SWTS-46

MOTOR DATA SHEET 1 Equipment Tag No./Description 2 Driven Equipment 3 Duty 4 Manufecturer 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 Notes:--1-2 Type Area Classification Frame Size/Designation Rated Kilowatt Output Voltage Full Load Current Full Load Speed

KW Frequency Amps Amps RPM

VENDOR TO FURNISH(*) * * Continuous(S1) CGL/KEC/SIEMENS/NGEF/BBL/ GEC/ALSTHOM Sq. Cage Induction Motor (Energy Efficient Motor) Safe Area/Hazardous Area(Zone 1/Zone-2) (whichever is applicable as per application) * * 4156% 503% * * ZoneTEFC,IP-55 (Ex-'d' for ) 1/Zone-2) * Class F(With temp. rise to class B) 50C/Limited to Cl 'B' insulation IS-325/IS-2148/IS-12615/IS-4029 & as per standard specificationof MV Motor * * * */*/* * * * * Refer Notes */*/* * * * * */* * */*/* * */240 Volts AC( Refer Notes) * * */* * 40KA for 0.25 Sec.for motors above 30KW

Enclosure( Ex 'd' in case of Zone 1/Zone 2) Mounting Insulation Class Ambient Temp/Temp Rise in C Applicable Codes/Standards Full Load Torque Starting Torque % of Full Load Torque Efficiency at 100% load Efficiency at 75%,50% & 25% load Rotation viewed from Non Driving End Bearing Type No. DE/NDE Type of Lubrication Coupling/Pully Cable Size/Type Phase/Connection/No. of Terminals No of Ploes Locked Rotor Current % Amps Locked Rotor Withstand time-Hot-Secs. Locked Rotor Withstand time-Cold-Secs. Stator/Rotor Time Constants Minutes Power Factor at 100% load Power Factor at 75%,50% &25% load Breakdown or Pull Out Torque % Space Heaters Watts/Volts GD of load GD of Motor Starting Time(At 100%V & 75% V) Secs. Canopy to be provided Fault Level

Cable size/Type(Cu/Al) shall be provided during drawing approval stage. The size of the cable for motor space heater shall be 2Cx4 Sqmm(Cu)1.1KV PVC sheathed armoured. 3 Motor for Hazardous area(i.e for crude oil pump) shall be Ex-'d' duly approved by DGMS. 4 Motor for water injectionpump shall be safe only. To BE FILLED BY THE VENDOR 1 The terminal box shall be spacious enough and shall be suitable for the cable size as Yes/No

SWTS-47

specified by ONGC during drawing approval stage. The cable gland shall be DGMS flame proof , double compression type brass nickel-plated type in case of flame proof motors(Ex-'d') The cable gland shall be double compression type brass nickel-plated type for Non FLP Motors The terminal box shall be suitable for type of enclosures selected for FLP/Non-FLP Motors The motor shall be painted with corrosion resistant epoxy paint of light grey;grade 631 as per IS:5 On- line Greasing arrangement shall be provided for motors offered.

Yes/No

Yes/No

Yes/No.

Yes/No

Yes/No Yes/No

Space heater of sufficient capacity shall be provided for the motors above 30KW Terminal box shall be rotatable through 360 at 90 interval Energy Efficient Motor Supplied(Efficiency guaranteed as per IS:12615) The flameproof motor shall be in accordance with IS:2148 and suitable for Zone1/Zone2 Gas groupIIA/IIB and temp.class T3 The following drawings/certificates shall be furnished for ONGC approval after LOI(prior to manufecturing clearance) a) Motor dimension drg. b) Hot/Cold withstand charaterstic curves of the motor c) A Copy of DGMS approval certificate for FLP(Ex-'d') Motor The following Third party Inspection/QA Deptt.of ONGC(whichever is applicable) release certificates alongwith the supply of the motors: a) Routine test Certificates b) Type test certificate

Yes/No

Yes/No

10

Yes/No

11

Yes/No

12

Yes/No