Copies or any other reproduction, including storage, treatment and dissemination by use of electronic systems must not be made for any other than the agreed purpose. Neither originals nor reproductions may be given to or made available to third parties.
SECTION A-A
Louvre for incoming air package controlled with weather protective lattice Air receiver
SECTION B-B
Recirculating air louvre thermostatically controlled Air exhaust fan temperature controlled Microfilteractivated carbon combination To the mains
Louvre for outgoing air thermostatically controlled with weather protective lattice Condensate main pipe 1900 1500 3592
Screw compressor
Screw compressor
1480
300
4500
800 1100 250
2 3 4
*
6 5 1 5
10
B
1200 Condensate treatment unit AQUAMAT 600
To the mains
4 8
Legend
Die Zeichnung bleibt unser ausschlieliches Eigentum. Sie wird nur zu dem vereinbarten Zweck anvertraut und darf zu keinem anderen Zweck verwendet werden. Kopien oder sonstige Vervielfltigungen einschlielich Speicherung, Verarbeitung oder Verbreitung unter Verwendung elektronischer Systeme drfen nur zu dem vereinbarten Zweck angefertigt werden. Weder Original noch Vervielfltigungen drfen Dritten ausgehndigt oder in sonstiger Weise zugnglich gemacht werden.
1 2 3 4 5 6 7 8 9 10 Screw compressor Hose line Ball valve Air receiver Condensate drain Refrigeration dryer Micofilter- activated carbon combination Condensate treatmente unit Air main charging system Hose coupling (Service Air main charging system)
Oil Water
1760
O 1400
Screw compressor
Air receiver
Compressormodel
5700
1000
Refrigeration dryer Louvre for incoming air package controlled with weather protective lattice
Bypass lines should not be fitted on standby units or when 100 % compressed air quality is required. The installation of item 4 should be chosen according operating conditions.
Air entrance Compressed Permissible overall Incomming aperture m free Air exhaust air air volume pressure loss for cross section duct m connection m/h per unit exhaust air p Pa per unit G2 1,2 9.900 0,5 80 G2 1,4 10.000 0,5 80 G2 1,8 11.500 0,5 60
Minimum air receiver ECO- DRAIN capacity l 3000 3000 5000 Microfilteractivated carbon combination model FFG- 107 B FFG- 107 B FFG- 138 B 13 13 13
Air entrance Refrigerationaperture m Incomming CompressorCompressed air Exhaust air fan for dryer model free cross air volume model connection each dryer m/h ** section per m/h per unit unit CSD 85 TD 76 G2 0,45 3500 3500 CSD 105 TE 91 G2 0,5 4500 4500 CSD 125 TE 121 G2 0,5 4500 4500
R 1 1/2 R 1 1/2 R2
CF 19 CF 19 CF 38
1060
A B
Condensate lines have to be connected to a collecting line via swan neck or are to be fed to the oil/water separator separately. A pressure-less drain has to be provided for.
This drawing also contains work to be done on site. The regulations of EN 1012 & VDE 0100 have to be observed; the requirements of existing operational safety ordinance and the manuals have to be considered by the operator and the employer respectively at the place of installation. The national safety and accident prevention regulations have to be observed.
A
300 ** Designed for reference terms DIN ISO 7183 Option A Ambient temperature min.: + 3 C max.: + 40 C
The installation of a sub- assembly in terms of the pressure equipment directive 97/23/EC has to be carried out according to this directive. P+I Scale Date
X X
Name
Inst. Name
1:50
31.05.2011 31.05.2011
blinzler1 Jeske
LYMU0004901e
Page 1 of 2
We reserve the right to make changes in the course of developement. This drawing can only be modified with CAD
Die Zeichnung bleibt unser ausschlieliches Eigentum. Sie wird nur zu dem vereinbarten Zweck anvertraut und darf zu keinem anderen Zweck verwendet werden. Kopien oder sonstige Vervielfltigungen einschlielich Speicherung, Verarbeitung oder Verbreitung unter Verwendung elektronischer Systeme drfen nur zu dem vereinbarten Zweck angefertigt werden. Weder Original noch Vervielfltigungen drfen Dritten ausgehndigt oder in sonstiger Weise zugnglich gemacht werden.
Drawings remain our exclusive property. They are entrusted only for the agreed purpose. Copies or any other reproduction, including storage, treatment and dissemination by use of electronic systems must not be made for any other than the agreed purpose. Neither originals nor reproductions may be given to or made available to third parties.
ATTENTION! Minimum width of door is total width of unit + 100 mm Safety codes on site have to be paid attention to. Condensate lines have to be connected to a collecting line via swan neck or are to be fed to the oil/water separator separately. A pressure-less drain has to be provided for.
This drawing also contains work to be done on site. The regulations of EN 1012 & VDE 0100 have to be observed; the requirements of existing operational safety ordinance and the manuals have to be considered by the operator and the employer respectively at the place of installation. The national safety and accident prevention regulations have to be observed. The installation of a sub- assembly in terms of the pressure equipment directive 97/23/EC has to be carried out according to this directive. P+I Scale Date
X X
Name
Inst. Name
1:20
31.05.2011 31.05.2011
blinzler1 Jeske
LYMU0004901e
Page 2 of 2
We reserve the right to make changes in the course of developement. This drawing can only be modified with CAD
Section A-A
Air main charging system Microfilteractivated carbon combination Air receiver 3592
Louvre for outgoing air thermostatically controlled with weather protective lattice
Section B-B
Air receiver
To the mains
Louvre for incoming air package controlled with weather protective lattice
4000
Screw compressor
800
1100
764 300
5 7 3 6 4 8
50
2
Drawings remain our exclusive property. They are entrusted only for the agreed purpose. Copies or any other reproduction, including storage, treatment and dissemination by use of electronic systems must not be made for any other than the agreed purpose. Neither originals nor reproductions may be given to or made available to third parties.
1300
800
520
To the mains
Oil Water
Legend 2160
O 1400
Air receiver
1 2 3 4 5 6 7 8 9
Screw compressor with integrated refrigeration dryer Hose line Ball valve Microfilter- activated carbon combination Pressure transducer Air receiver tank Air main charging system Hose coupling (Service AMCS) Condensate treatment unit
Die Zeichnung bleibt unser ausschlieliches Eigentum. Sie wird nur zu dem vereinbarten Zweck anvertraut und darf zu keinem anderen Zweck verwendet werden. Kopien oder sonstige Vervielfltigungen einschlielich Speicherung, Verarbeitung oder Verbreitung unter Verwendung elektronischer Systeme drfen nur zu dem vereinbarten Zweck angefertigt werden. Weder Original noch Vervielfltigungen drfen Dritten ausgehndigt oder in sonstiger Weise zugnglich gemacht werden.
A
Louvre for incoming air package controlled with weather protective lattice
4500
B 4900
Condensate lines have to be connected to a collecting line via swan neck or are to be fed to the oil/water separator separately. A pressure-less drain has to be provided for.
Safety codes on site have to be paid attention to. Ambient temperature min.: + 3 C max.: + 40 C
This drawing also contains work to be done on site. The regulations of EN 1012 & VDE 0100 have to be observed; the requirements of existing operational safety ordinance and the manuals have to be considered by the operator and the employer respectively at the place of installation. The national safety and accident prevention regulations have to be observed. The installation of a sub- assembly in terms of the pressure equipment directive 97/23/EC has to be carried out according to this directive. P+I Scale Date
X X
Name
Inst. Name
1:20
LYMU0002001e
Page 1 of 2
We reserve the right to make changes in the course of developement. This drawing can only be modified with CAD
Die Zeichnung bleibt unser ausschlieliches Eigentum. Sie wird nur zu dem vereinbarten Zweck anvertraut und darf zu keinem anderen Zweck verwendet werden. Kopien oder sonstige Vervielfltigungen einschlielich Speicherung, Verarbeitung oder Verbreitung unter Verwendung elektronischer Systeme drfen nur zu dem vereinbarten Zweck angefertigt werden. Weder Original noch Vervielfltigungen drfen Dritten ausgehndigt oder in sonstiger Weise zugnglich gemacht werden.
Drawings remain our exclusive property. They are entrusted only for the agreed purpose. Copies or any other reproduction, including storage, treatment and dissemination by use of electronic systems must not be made for any other than the agreed purpose. Neither originals nor reproductions may be given to or made available to third parties.
This drawing also contains work to be done on site. The regulations of EN 1012 & VDE 0100 have to be observed; the requirements of existing operational safety ordinance and the manuals have to be considered by the operator and the employer respectively at the place of installation. The national safety and accident prevention regulations have to be observed.
Safety codes on site have to be paid attention to. ATTENTION! Minimum width of door is total width of unit + 100 mm
Condensate lines have to be connected to a collecting line via swan neck or are to be fed to the oil/water separator separately. A pressure-less drain has to be provided for.
The installation of a sub- assembly in terms of the pressure equipment directive 97/23/EC has to be carried out according to this directive. P+I Scale Date
X X
Name
Inst. Name
1:20
LYMU0002001e
Page 2 of 2
We reserve the right to make changes in the course of developement. This drawing can only be modified with CAD
Drawings remain our exclusive property. They are entrusted only for the agreed purpose. Copies or any other reproduction, including storage, treatment and dissemination by use of electronic systems must not be made for any other than the agreed purpose. Neither originals nor reproductions may be given to or made available to third parties.
Section A-A
Louvre for incoming air package controlled with weather protective lattice
Louvre for outgoing air thermostatically controlled with weather protective lattice
Section B-B
Air receiver Screw compressor 1902 Screw compressor Condensate main pipe
3592
4000
6800
B
800
800
1100
800
1100 300
5
Control line 6
i p
7 4
To the mains
1300
Legend
1 1 2 3 4 5 6 7 8 9 10 4 Screw compressor with integrated refrigeration dryer Hose line Ball valve Microfilter- activated carbon combination Control SAM Pressure transducer Air receiver tank Air main charging system Hose coupling (Service Air main charging system) Condensate treatment unit
Die Zeichnung bleibt unser ausschlieliches Eigentum. Sie wird nur zu dem vereinbarten Zweck anvertraut und darf zu keinem anderen Zweck verwendet werden. Kopien oder sonstige Vervielfltigungen einschlielich Speicherung, Verarbeitung oder Verbreitung unter Verwendung elektronischer Systeme drfen nur zu dem vereinbarten Zweck angefertigt werden. Weder Original noch Vervielfltigungen drfen Dritten ausgehndigt oder in sonstiger Weise zugnglich gemacht werden.
2160
O 1400
4500
Air receiver Screw compressor Screw compressor Air main charging system
Condensate lines have to be connected to a collecting line via swan neck or are to be fed to the condensate treatment system separately. A pressure-less drain has to be provided for.
1 10 Condensate line
Oil
Water
Control SAM
To the mains ATTENTION! Minimum width of door is total width of unit + 100 mm
This drawing also contains work to be done on site. The regulations of EN 1012 & VDE 0100 have to be observed; the requirements of existing operational safety ordinance and the manuals have to be considered by the operator and the employer respectively at the place of installation. The national safety and accident prevention regulations have to be observed. The installation of a sub- assembly in terms of the pressure equipment directive 97/23/EC has to be carried out according to this directive. P+I Scale Date
Air entrance Permissible Compressed aperture m Incoming air overall pressure Exhaust air Minimum air Air exhaust air free cross volume m/h loss for fan for each receiver ECO- DRAIN duct m connection section per per unit exhaust air dryer m/h capacity l unit duct p Pa CSD 85 T G2 1,4 12000 0,5 80 2500 3000 13 CSD 105 T G2 1,6 12100 0,5 80 2500 3000 13 CSD 125 T G2 2 15500 0,5 60 4900 5000 13
MicrofilterCondensate activated Compressed treatment carbon air unit combination connection AQUAMAT model FFG- 107 B R 1 1/2 CF 38 FFG- 107 B R 1 1/2 CF 38 FFG- 138 B R2 CF 75
X X
Name
Inst. Name
1:20
11.07.2011 11.07.2011
blinzler1 Jeske
LYMU0002101e
Page 1 of 2
We reserve the right to make changes in the course of developement. This drawing can only be modified with CAD
Die Zeichnung bleibt unser ausschlieliches Eigentum. Sie wird nur zu dem vereinbarten Zweck anvertraut und darf zu keinem anderen Zweck verwendet werden. Kopien oder sonstige Vervielfltigungen einschlielich Speicherung, Verarbeitung oder Verbreitung unter Verwendung elektronischer Systeme drfen nur zu dem vereinbarten Zweck angefertigt werden. Weder Original noch Vervielfltigungen drfen Dritten ausgehndigt oder in sonstiger Weise zugnglich gemacht werden.
Drawings remain our exclusive property. They are entrusted only for the agreed purpose. Copies or any other reproduction, including storage, treatment and dissemination by use of electronic systems must not be made for any other than the agreed purpose. Neither originals nor reproductions may be given to or made available to third parties.
This drawing also contains work to be done on site. The regulations of EN 1012 & VDE 0100 have to be observed; the requirements of existing operational safety ordinance and the manuals have to be considered by the operator and the employer respectively at the place of installation. The national safety and accident prevention regulations have to be observed. The installation of a sub- assembly in terms of the pressure equipment directive 97/23/EC has to be carried out according to this directive. P+I Scale Date
Safety codes on site have to be paid attention to. ATTENTION! Minimum width of door is total width of unit + 100 mm
Condensate lines have to be connected to a collecting line via swan neck or are to be fed to the oil/water separator separately. A pressure-less drain has to be provided for.
X X
Name
Inst. Name
1:20
11.07.2011 11.07.2011
blinzler1 Jeske
LYMU0002101e
Page 2 of 2
We reserve the right to make changes in the course of developement. This drawing can only be modified with CAD