You are on page 1of 2

SectionB 2004.

qxd

6/26/04

10:37 AM

Page B-9

ROTRON Regenerative Blowers

DR 303M & CP 303M Regenerative Blower


FEATURES
Manufactured in the USA ISO 9001 compliant CE compliant Declaration of Conformity on file Maximum flow: 55 SCFM Maximum pressure: 45 IWG Maximum vacuum: 3.4" Hg (42 IWG) Standard motor: 0.5 HP, TEFC Cast aluminum blower housing, impeller & cover; cast iron flanges (threaded) UL & CSA approved motor with permanently sealed ball bearings Inlet & outlet internal muffling Quiet operation within OSHA standards

MOTOR OPTIONS
International voltage & frequency (Hz) Chemical duty, high efficiency, inverter duty or industry-specific designs Various horsepowers for application-specific needs

BLOWER OPTIONS
Corrosion resistant surface treatments & sealing options Remote drive (motorless) models Slip-on or face flanges for application-specific needs ACCESSORIES (See Catalog Accessory Section) Flowmeters reading in SCFM Filters & moisture separators Pressure gauges, vacuum gauges & relief valves Switches air flow, pressure, vacuum or temperature External mufflers for additional silencing Air knives (used on blow-off applications) Variable frequency drive package

BLOWER PERFORMANCE AT STANDARD CONDITIONS


AIR FLOW RATE (M3/MIN)
0.5 2.0 55 1.0 1.5 2.0 4 1250 -45 INCHES OF MERCURY INCHES OF WATER 1000 MM OF WATER 35 60 Hz 750 3
0 0.5 50

AIR FLOW RATE (M3/MIN)


0.5 -55 1.0 1.5 2.0

PRESSURE

AIR FLOW RATE (m3/MIN)


1

SUCTION
1.5 2

1250
1200

45 INCHES OF WATER 1.5

1000 MM OF WATER

-35

40

SUCTION

1000 800

INCHES OF WATER

PSIG

1.0

25 50 Hz

60 Hz
60 Hz

-25
20 50 Hz 10 -15

600

500 15

400 500

50 Hz
200 0 0 10 20 30 40 50 60 70

0.5

250 5 0 MOTOR WINDING TEMP RISE C 10 20 30 40 50 60 70 MOTOR POWER WINDING INPUT WATTS TEMP RISE C

250

-5

AIR FLOW RATE (SCFM)

10

20

30

40

50

60

70

AIR FLOW RATE (SCFM)


80 60 40 20 600 500 400 300 200 60 50 40 30 20 80 60 40 20 600 500 400 300 200 60 50 40 30 20

AIR FLOW RATE (SCFM)

POWER INPUT WATTS

Rev. 2/04

B-9

BLOWER AIR TEMP RISE C

AMETEK Technical and Industrial Products, Kent, OH 44240 e mail: rotronindustrial@ametek.com internet: www.ametektmd.com

BLOWER AIR TEMP RISE C

mm H2O

30

750

SectionB 2004.qxd

6/26/04

10:37 AM

Page B-10

ROTRON Regenerative Blowers

DR 303M & CP 303M Regenerative Blower


Scale CAD drawing available upon request.

IN MM TOLERANCES: .XX DIMENSIONS:

A B

.68 INCH DIAMETER CONNECTOR HOLE

.08 2 (UNLESS OTHERWISE NOTED)

CAPACITOR LOCATION ON SINGLE PHASE MOTORS

SPECIFICATIONS
MODEL Part No. Motor Enclosure Shaft Material Horsepower Voltage 1 Phase Frequency 1 Insulation Class 2 NEMA Rated Motor Amps Service Factor Locked Rotor Amps Max. Blower Amps 3 Recommended NEMA Starter Size Shipping Weight
1

DR303AE9M 038841 TEFC CS 0.5 115/230 Single - 60 Hz F 6.2/3.1 1.25 21/10.5 6/3 0/00 40 lb (18.2 kg)

DR303AE72M 038842 TEFC CS 0.5 208-230/460 Three - 60 Hz F 1.3-1.2/0.6 1.25 10-9.2/4.6 1.63/0.83 00/00 36 lb (16.3 kg)

DR303AE86M 038843 TEFC CS 0.5 575 Three - 60 Hz F 0.6 1.25 4.2 0.7 00 35 lb (15.9 kg)

CP303FA91MLR 080148 Chem TEFC SS Same as DR303AE72M 038842 except add Chemical Processing (CP) features from catalog inside front cover

Rotron motors are designed to handle a broad range of world voltages and power supply variations. Our dual voltage 3 phase motors are factory tested and certified to operate on both: 208-230 /415-460 VAC- 3 ph- 60 Hz and 190-208/380-415 VAC- 3 ph- 50 Hz. Our dual voltage 1 phase motors are factory tested and certified to operate on both: 104-115 / 208-230 VAC-1 ph- 60 Hz and 100-110 /200-220 VAC-1 ph- 50 Hz. All voltages above can handle a 10% voltage fluctuation. Special wound motors can be ordered for voltages outside our certified range. Maximum operating temperature: Motor winding temperature (winding rise plus ambient) should not exceed 140C for Class F rated motors or 120C for Class B rated motors. Blower outlet air temperature should not exceed 140C (air temperature rise plus inlet temperature). Performance curve maximum pressure and suction points are based on a 40C inlet and ambient temperature. Consult factory for inlet or ambient temperatures above 40C. Maximum blower amps corresponds to the performance point at which the motor or blower temperature rise with a 40C inlet and/or ambient temperature reaches the maximum operating temperature.

Specifications subject to change without notice. Please consult your Local Field Sales Engineer for specification updates.

Rev. 2/04

AMETEK Technical and Industrial Products, Kent, OH 44240 e mail: rotronindustrial@ametek.com internet: www.ametektmd.com