You are on page 1of 56

Peripheral Products

Liquid and air flow Air quality and gas detection Fan Speed and electric heater controllers Input / Output modules Water and energy meters Peripherals and interfaces Pressure Relative humidity Wireless devices Temperature Valves and actuators

2013

Peripheral Programme

Dear Customer, I am excited to introduce to you our complete range of peripheral products. By offering a wide range of products we hope to fulfil the demands of all of your projects whilst also simplifying installation and optimization of building control systems. We provide all of this whilst guaranteeing reduced installation costs. In order to create this peripheral products catalogue we have implemented strong partnerships with first-class genuine parts manufacturers. Our aim is to provide our customer with a range of peripheral products that complement our building automation offering and give a complete, supported solution for specification and installation of your projects. Inside this catalogue you will find a vast range of products designed to control and enhance any building automation system including valves, actuators, probes, sensors and HVAC drives. There is also a wireless and battery-less range which is intended to replace traditional wired systems and offer enhanced reliability as well as simplicity of installation and cost savings on installation and operation. We continually invest in development of new products by building on detailed research into the requirements and opinions of our customers along with industry trends. Distech Controls is ISO-9001 certified and seeks to ensure quality products and services, attentive customer service and technical support as well as efficient after sales service. We consider the satisfaction of our customers as the heart of our activity. With regards, Martin Villeneuve Vice President Europe & Africa

TO BE DISCOVERED... Our 3 major product categories


Probes and Sensors
A new sleek and modern range of sensing products for temperature, relative humidity, CO2 and air quality!
Designed to offer a streamlined and uniform look to your application.

See pages 38 to 41 for more information.

Wireless and Battery-less Sensors A range of sensing devices containing EnOcean technology for flexible and cost-efficient applications. Particularly suited for repartitioning projects.
Temperature sensors in a range application

types such as outside air, duct, pipework contact and room. Relative Humidity & Temperature Sensors Occupancy Detectors and Door/Window Contact Sensors Ambient and Outside Light Sensor See page 29 to 32 for more information.

Valves and Actuators

Our new range of terminal unit valves and thermic actuators offer an extremely cost effective solution.
2, 3 and 4 way Terminal Unit Valves Thermic Terminal Unit Valve Actuators Spring Return Terminal Unit Valve Actuators

See page 42 to 49 for more information.

Innovative Solutions for Greener Buildings

Contents
Air & Water Flow

Page

PDCSY-AV PDCSY-FS PDCSY-LS


Air Quality & Gas Detection

Air Velocity Sensors & Probes Air & Liquid Flow Switch Liquid Level Switches & Sensors

4 7 15-16

PDCSY-GL PDCSY-GS PDCSY-SD


Controllers

Gas Leak Alarm Systems Air Quality, Carbon Dioxide/RH & T & Gas Sensors Duct Smoke Detectors

7 8-10 36

PDCSY-FC PDCSY-RE HVAC Drives


Input/Output Modules

Fan Speed Controllers Electric Heater Battery Controllers HVAC Drives

6 28-29 10-11

PDCSY-IO
Water & Energy Metering

Input/Output Modules

12-14

PDCSY-MW
Peripheral & Interfaces

Water Meters, Integrators & Flow Sensors

17-20

PDCSY-EP PDCSY-MG PDCSY-PM PDCSY-PS PDCSY-UI PDCSY-WD


Pressure

Emergency Switches/Buttons & Thermal Link Gas metering Energy Analysers & Power Monitoring Power Output Supplies Alarms Annunciators Water Detection Systems & Sensors

5 16 25-27 28 41 42

PDCSY-PA PDCSY-PL SR65 SRx/41-x/EPM


Wireless SonNet

Air DP Sensors & Switches Liquid Pressure Sensors & Switches

21-22 23-25

EnOcean Wireless Probes & Sensors Temperature Probes & Sensors Other EnOcean Accessories 29-30 30-32

PDCSY-RF
Relative Humidity

Sensors, Routers, Receivers & Site Survey Kit

33-35

PDCSY-RH
Temperature

Relative Humidity and Temperature Sensors & Humidistats

35-36

PDCSY-ST PDCSY-TT
Valves and actuators

Temperature Thermostats Temperature Sensors & Pockets

37-38 38-41

PDCBP-VN PDCBP-A2004 PDCSY-VT PDCSY-VS PDCSA xM, xF Series

Valve Actuators Thermic actuators Terminal Valves & Actuators Gas Valves Valves & Actuators Damper Actuators

42-43 43 43-44 46-47 47 47-49


50

Thermistor Types & Compatibility Charts

Tel: +33 (0) 4 78 45 01 23 Fax: +33 (0) 4 78 45 22 33 web: www.distech-controls.eu

Peripheral Programme

PDCSY-AV-DSP

Single-point Air Velocity Sensor

PDCSY-AV-MPS

Multi-point Air Velocity Probes (S/S)

The PDCSY-AV-DSP is a single-point, multi-range Air Velocity Transmitter with user selectable 0-10 VDC or 4-20 mA outputs and four user selectable measurement ranges. The unit has a built-in selftest feature and the user can manually override the output to 0%, 50% or 100% of output range to aid commissioning. FEATURES User selectable 0-10 VDC or 4-20 mA outputs Built-in self-test feature Built-in manual override facility for 0%, 50% or 100% of output range Durability and resistance to chemical reagents 0 to 4 m/s, 0 to 8 m/s, 0 to 16 m/s, 0 to 32 m/s selectable ranges

A Multi-point Air Velocity Sensor for use in larger ducts or where turbulent airflow is likely to be encountered. Stainless steel construction is used for the tubing and all gaskets are provided. FEATURES Mounting plate to suit flat ducts Double gasket seals the probe to the duct Available in lengths from 700 mm to 2000 mm Push on connectors to suit PDCSY-PA-TUBE-8mm The PDCSY-AV-MPS can be connected to a PDCSY-PA-267 or PDCSY-PA-699. Differential Pressure Sensor of an appropriate range (please refer to Datasheet on Distechs website for further information). The output of the sensor represents the velocity pressure and is defined by the following equation: Velocity = Part code PDCSY-AV-MPS700 PDCSY-AV-MPS800 PDCSY-AV-MPS1000 PDCSY-AV-MPS1250 PDCSY-AV-MPS1500 PDCSY-AV-MPS1750 PDCSY-AV-MPS200 PDCSY-PA-TUBE-8MM (2 x Velocity Pressure) / 1.2 Description Multi-point Air Velocity Probe (S/S) 700 mm Multi-point Air Velocity Probe (S/S) 800 mm Multi-point Air Velocity Probe (S/S) 1000 mm Multi-point Air Velocity Probe (S/S) 1250 mm Multi-point Air Velocity Probe (S/S) 1500 mm Multi-point Air Velocity Probe (S/S) 1750 mm Multi-point Air Velocity Probe (S/S) 2000 mm Accessory PVC tube 8 mm o/d x 1.5 mm wall, 30 m reel Datasheet PDCSY-AV-MPS.pdf

SPECIFICATION Output Accuracy Supply (current output) Supply (voltage output) Max. current Ambient temp. range Housing Probe Protection Weight 4-20 mA, 100 loop resistance min. 0-10 VDC into 4.7 k min. 0 to 4 m/s 0.12 m/s 0 to 8 m/s 0.24 m/s 0 to 16 m/s 0.48 m/s 0 to 32 m/s 0.96 m/s 20 to 35 VDC for 500 loop resistance 12 to 30 VDC for 100 loop resistance 17 to 34 VDC, 14 to 26 VAC supply into 4.7 k min. 50 mA 10 to +50C Material Flame retardant ABS Dimensions 55 x 90 mm dia. Material Delrin Dimensions 215 x 19 mm dia. IP65 280 g

Part code PDCSY-AV-DSP PDCSY-DPA

Description Air Velocity Sensor 240 mm probe Accessory Duct probe adjustment flange Datasheet PDCSY-AV-DSP.pdf

PDCSY-AV-W

Wind Speed and Direction Sensors

PDCSY-AV-EP

Multi-point Air Velocity Probes (ABS)

FEATURES Mounting plate to suit flat, round and oval ducts Double gasket seals the probe to the duct Available in lengths from 100 mm to 600 mm Puh on connectors to suit PDCSY-PA-TUBE-8mm Ideal for small attenuators Perfect for fresh air inlet louvres The PDCSY-AV-EP can be connected to a PDCSY-PA-267 or PDCSY-PA-699 Differential Pressure Sensor of an appropriate range (please refer to Datasheet on Distech s website for further information). The output of the sensor represents the velocity pressure and is defined by the following equation: Velocity = (2 x Velocity Pressure) / 1.2

The PDCSY-AV-WS measures wind speed providing a pulsed output and is intended for applications where external weather conditions influence the building control strategy, such as for the automatic closing of windows. A mounting arm and U bolts for pole mounting are included. COMMON SPECIFICATION Electrical conns Flying lead (3 m long) Ambient range 20 to +70C Dimensions Height 280 mm (max. arc 120mm) Protection IP65 SPECIFICATION PDCSY-AV-WS Output 1 contact closure per 1.493 metre (zero bounce) Min. start speed 0.5 m/s Accuracy 2% Contact rating Power 50 W max. (DC resistive) Voltage 100 VDC max. Current 1 A max. Weight: 1.46 kg SPECIFICATION PDCSY-AV-WAD Mechanical travel: 360 endless travel Electrical travel: 357 ( 2) Output: 0 to 1 k for 0 to 357 @ 80 VDC max. Weight: 1.56 kg

Note: The PDCSY-AV-EP must be mounted a minimum of 2m away from any bends, fans, heating batteries etc. in the duct-work. Always point the flow direction arrow on the probe flange into the air flow. Part code PDCSY-AV-EP100 PDCSY-AV-EP200 PDCSY-AV-EP300 PDCSY-AV-EP400 PDCSY-AV-EP500 PDCSY-AV-EP600 Description Multi-point Air Velocity Probe (ABS) 100 mm Multi-point Air Velocity Probe (ABS) 200 mm Multi-point Air Velocity Probe (ABS) 300 mm Multi-point Air Velocity Probe (ABS) 400 mm Multi-point Air Velocity Probe (ABS) 500 mm Multi-point Air Velocity Probe (ABS) 600 mm Accessory PDCSY-AV-TUBE-8MM PVC pipe 8 mm x 30 m Datasheet PDCSY-AV-EP.pdf

Part code PDCSY-AV-WS PDCSY-AV-WAD

Description Wind Speed Sensor Wind Speed and Direction Sensor Datasheet PDCSY-AV-W.pdf

Innovative Solutions for Greener Buildings

PDCSY-EP-FS

Firemans Switches

PDCSY-EP-SW72 Fusible Thermal Link


The PDCSY-EP-SW72 is for use in gas safety circuits. Units consist of a ventilated high temperature glass filled resin case, with electrical connection terminals and a thermal fuse. When located above boilers, the fuse activates on detection of over-temperature to close down the gas system. Replacement fuses are available. SPECIFICATION Housing Entry Melting point Rating Protection Dimensions Weight Part code PDCSY-EP-SW72 PDCSY-EP-SW72-F

This range of Safety Switches is for use in the event of fire or other emergency. Usually located at exits to gas plant rooms, units are key operated with a 2 or 3-position latching switch. SPECIFICATION Switch rating Keys Connections Dimensions Weight Part code PDCSY-EP-FS1 PDCSY-EP-FS2 PDCSY-EP-FSC 6 A @ 240 VAC 2 supplied (removable in all positions) 4 x 100 mm flying leads 86 x 86 x 50 mm 200 g Description Firemans Switch Red 2-position Firemans Switch Red 3-position Firemans Switch Hinged cover Datasheet PDCSY-EP-FS.pdf

High temperature flame retardent glass filled resin M20 thread for standard conduit 72C 250 VAC @ 5 A IP20 85 x 28 x 65 mm 60 g Description Electro-thermal Link Electro-thermal Link spare fuse Datasheet PDCSY-EP-SW72.pdf

PDCSY-EP-KG

Firemans Keyguard

The PDCSY-EP-KG is a wall or panel-mounted Keyguard. The window is a non-hazardous clear plastic with side tabs designed to break in order to gain access to the key. It is ideal for use in situations where a glass window would pose a hazard, i.e. food preparation areas, schools etc. SPECIFICATION Housing Dimensions Weight ABS plastic 142 x 125 x 45 mm 220 g

Part code PDCSY-EP-KG1 PDCSY-EP-KGW

Description Firemans Keyguard Red Firemans Keyguard Spare window Datasheet PDCSY-EP-KG.pdf

PDCSY-EP-SW

Emergency Stop Buttons

A range of Emergency Stop Buttons for manual shutdown of systems in the event of fire or other emergencies SPECIFICATION Switch rating PDCSY-EP-KL 15 to 415 VAC, 4 A 13 to 110 VDC, 0.5 A Others 6 A @ 240 VAC Reset type PDCSY-EP-KL Key PDCSY-EP-SW10 Push (recessed) PDCSY-EP-SW11 Twist Dimensions PDCSY-EP-KL 65 x 65 x 90 mm PDCSY-EP-SW10 73 x 80 x 50 mm PDCSY-EP-SW11 65 x 65 x 90 mm Weight 220 g

Part code PDCSY-EP-KL PDCSY-EP-SW10 PDCSY-EP-SW11

Description Emergency Stop Button Key lock Emergency Stop Button Push button (recessed) Emergency Stop Button Twist knob Datasheet PDCSY-EP-ES.pdf

Tel: +33 (0) 4 78 45 01 23 Fax: +33 (0) 4 78 45 22 33 web: www.distech-controls.eu

Peripheral Programme
PDCSY-FC-MTY Manual Speed Controllers for small motors

PDCSY-FC-DIN

Fan Speed Controllers (DIN-rail)

The PDCSY-FC-DIN range of DIN-rail mounting Fan Speed Controllers offer user selectable 0-10 VDC, 4-20 mA input control signal compatibility for automatic control, and a 3-wire potentiometer input for manual control. The PDCSY-FC-DIN are available in 1 A, 3 A and 5 A single phase ratings. A fast start function is available, with user definable time, as well as user definable minimum and maximum run speeds. A simple linear input/output characteristic is selectable, and there is also a feature which allows a user to define, at 16 points, an input/output curve to suit a specific fan or application. FEATURES User definable maximum and minimum speed Fast on normal start up User definable fast start time Downloadable configuration software APPLICATION Fan or pump speed control, for energy and cost savings. SPECIFICATION Supply Frequency Inputs Output Mounting Ambient Range Dimensions Weight Part code PDCSY-FC-DIN1 PDCSY-FC-DIN3 PDCSY-FC-DIN5 PDCSY-FC-DIN1-SP PDCSY-FC-DIN3-SP PDCSY-FC-DIN5-SP 230 VAC -6% +10% 47 to 64 Hz 4-20 mA (not loop powered) 0-10 VDC 0-10 k 3-wire potentiometer Triac, phase angle DIN-rail 10 to +50C, 5 to 95% RH non-condensing 125 x 75 x 80 mm 350 g Description 1 A, 230 V, Single Phase Auto Fan Speed Controller 3 A, 230 V, Single Phase Auto Fan Speed Controller 5 A, 230 V, Single Phase Auto Fan Speed Controller 1 A, 230 V, Single Phase Manual Fan Speed Controller 3 A, 230 V, Single Phase Manual Fan Speed Controller 5 A, 230 V, Single Phase Manual Fan Speed Controller Datasheet PDCSY-FC-DIN.pdf

Manual control for small, single-phase motors up to 4 amps. Suitable for wall and/or flush mounting. SPECIFICATION Nominal supply Control type On/off switch Pot. action Minimum speed Current ratings Fuse Fuse ratings Mounting style Protection Dimensions Weight 230 VAC, 1-phase, 50-60 Hz Manual via potentiometer Inbuilt with pot. Clockwise = min. to max. speed Adjustable via trim pot PDCSY-FC-MTY1 - 0.1 to 1.0 A PDCSY-FC-MTY2 - 0.2 to 2.0 A PDCSY-FC-MTY4 - 0.4 to 4.0 A 20 mm FF type PDCSY-FC-MTY1 - FF 1.25 A PDCSY-FC-MTY2 - FF 2.5 A PDCSY-FC-MTY4 - FF 5 A Wall and flush mount (PDCSY-FC-MTY4 wall mount only) PDCSY-FC-MTY1, MTY2 IP44 PDCSY-FC-MTY4 IP54 Wall mount 82 x 82 x 65 mm Flush mount 82 x 82 x 56 mm 360 g max.

Part code PDCSY-FC-MTY1 PDCSY-FC-MTY2 PDCSY-FC-MTY4

Description Manual Speed Controller, 1 A, 230V, 1-phase Manual Speed Controller, 2 A, 230V, 1-phase Manual Speed Controller, 4 A, 230V, 1-phase Datasheet PDCSY-FC-MTY.pdf

PDCSY-FC-STL

Manual Speed Controllers

This range of Manual Speed Controllers provide single-phase voltage control for AC motors, by varying the supplied voltage through phase-angle control. SPECIFICATION Nominal supply On/off switch Starting sequence Pot. action Minimum speed Current ratings Fuse Fuse ratings Mounting style Protection Dimensions Weight Part code PDCSY-FC-STL3D PDCSY-FC-STL5D PDCSY-FC-STL10D 230 VAC 1-phase 50-60 Hz Separate to potentiometer Full speed for 6 to 7 secs Clockwise = max. to min. speed Adjustable via trim pot. PDCSY-FC-STL3D - 0.3 to 3.0 A PDCSY-FC-STL5D - 0.5 to 5.0 A PDCSY-FC-STL10D - 1.0 to 10.0 A 20 mm FF type PDCSY-FC-STL3D - FF 5 A PDCSY-FC-STL5D - FF 8 A PDCSY-FC-STL10D - FF 14 A Wall mount IP54 PDCSY-FC-STL3D 83 x 160 x 88 mm PDCSY-FC-STL5D/STL10D 88 x 195 x 115 mm 740 g max. Description Manual Fan Speed Controller, 3 A, type D, 1-phase Manual Fan Speed Controller, 5 A, type D, 1-phase Manual Fan Speed Controller, 10 A, type D, 1-phase Datasheet PDCSY-FC-STL.pdf

PDCSY-FC-ERV

Fan Speed Controllers

The PDCSY-FC-ERV can control the speed of single-phase, voltage controllable electric motors, with a 0-10 VDC or 4-20 mA control signal. Centrifugal fans, axial fans, propeller fans and centrifugal pumps are prime candidates for electronic speed control. SPECIFICATION Nominal supply Control type On/off switch Remote signal Starting speed Pot. action Minimum speed Current ratings Fuse Fuse ratings 230 VAC 1-phase 50-60 Hz Automatic from remote signal Mounted on side Two wire 4-20 mA or 0-10 VDC According to signal value Not applicable Adjustable via trim pot. PDCSY-FC-ERV1 - 0.1 to 1.5 A PDCSY-FC-ERV3 - 0.3 to 3.0 A PDCSY-FC-ERV5 - 0.5 to 5.0 A PDCSY-FC-ERV10 - 1.0 to 10.0 A 20 mm FF type PDCSY-FC-ERV1 - FF 3 A PDCSY-FC-ERV3 - FF 5 A PDCSY-FC-ERV5 - FF 8 A PDCSY-FC-ERV10 - FF 14 A Wall mount IP54 88 x 195 x 115 mm 810 g max. Description Fan Speed Controller, 1 A, 230 V, 1-phase Fan Speed Controller, 3 A, 230 V, 1-phase Fan Speed Controller, 5 A, 230 V, 1-phase Fan Speed Controller, 10A, 230 V, 1-phase Datasheet PDCSY-FC-ERV.pdf

Mounting style Protection Dimensions Weight Part code PDCSY-FC-ERV1 PDCSY-FC-ERV3 PDCSY-FC-ERV5 PDCSY-FC-ERV10

Innovative Solutions for Greener Buildings

PDCSY-FS-521

Air Flow Switch

PDCSY-GL-CO

Gas Leak Alarm Systems

This Paddle Switch is intended to monitor air flow within a duct and provides a switched output on detection of either a specific air velocity or flow failure. FEATURES Adjustable switching point Lid-mounting screws provide tamper proofing SPECIFICATION Operating temp Materials Switch rating Protection Dimensions Weight Part code PDCSY-FS-521

A range of stand-alone Gas Leak Alarm Systems for use in commercial / industrial gas installations to provide safety alarm and shutdown facilities on detection of gas leakage. FEATURES 1, 2 & 3 channel options Audio and visual alarms Adjustable alarm sensitivity Relay output for gas shut-off valves Relay output for remote alarms Auto or manual reset selectable Self-diagnosis fault system SENSOR TYPES Natural Gas Sensor Propane Sensor Carbon Monoxide Sensor PDCSY-GL-CO-SRS150 PDCSY-GL-CO-SRS250 PDCSY-GL-CO-SRS350

Ambient 20 to +70C (max.) Media 20 to +120C (max.) Paddle Stainless steel Rod Brass Enclosure ABS flame retardant (type VO) 15 (8) A SPDT @ 230 VAC IP65 Paddle 80 x 180 mm Housing 113.5 x 65 x 62 mm 300 g Description Air Flow Switch 80 x 175 mm paddle Datasheet PDCSY-FS-521.pdf

MOUNTING The PDCSY-GL-CO-RFG361 is DIN-rail mounted. A panel mounting kit PDCSY-GL-CO-RFG-FMK3 is available separately. The PDCSY-GL-CO-RFG65x series are DIN-rail mounted. A panel mounting kit PDCSY-GL-CO-RFG-FMK6, or wall mounting kit PDCSY-GL-CO-RFG-WMK6 are available separately. SPECIFICATION Power supply 230 VAC 10% @ 50/60 Hz or 12 V 10% Relay output(s) PDCSY-GL-CO-RFG361 SPDT, 250 V @ 5 (1) A PDCSY-GL-CO-RFG65x 2 x SPDT, 250 V @ 5 (1) A Materials Base Nylon Cover ABS Ambient Storage temp. 25 to +60C Operating temp. 0 to 45C Relative humidity Class F DIN 40040 Protection IP40 Weight PDCSY-GL-CO-RFG361 250 g PDCSY-GL-CO-RFG65x 600 g Part code PDCSY-GL-CO-RFG361 PDCSY-GL-CO-RFG651 PDCSY-GL-CO-RFG652 PDCSY-GL-CO-RFG653 PDCSY-GL-CO-RFG-FMK3 PDCSY-GL-CO-RFG-FMK6 PDCSY-GL-CO-RFG-WMK6 PDCSY-GL-CO-SRS150 PDCSY-GL-CO-SRS250 PDCSY-GL-CO-SRS350 Description Controllers (DIN-rail mount) Gas Leak Alarm System 1-channel, 1 x SPDT Gas Leak Alarm System 1-channel, 2 x SPDT Gas Leak Alarm System 2-channel, 2 x SPDT Gas Leak Alarm System 3-channel, 2 x SPDT Options Panel door mounting kit for RFG361 Panel door mounting kit for RFG65x Wall mounting kit for RFG65x Sensors Combustibles Sensor (natural gas) Propane / LPG Sensor Carbon Monoxide Sensor

PDCSY-FS-541

Liquid Flow Switches

The PDCSY-FS-541 series of Paddle Switches are intended to monitor liquid flow within pipes and provides a VFC output on detection of either a specific flow rate or flow failure. They screw directly into a 1 BSPT boss. FEATURES Adjustable switching point Stainless steel wetted parts for aggressive media SPECIFICATION Operating temp Ambient 40 to +85C (max.) Media 40 to +120C (max.) Operating pressure 1100kPa (max.) Materials Paddle Stainless steel Rod Brass (S/S for PDCSY-FS-541S) Enclosure ABS flame retardant Switch rating 15 (8) A SPDT @ 24-250 VAC, VFC Pipe suitability 1 to 8 Protection IP65 Dimensions Housing 113.5 x 65 x 62 mm Paddles 28.5, 54.5, 83.5 and 161.5 mm Weight 300 g Part code PDCSY-FS-541 PDCSY-FS-541S Description Liquid Flow Switch 1 BSPT Liquid Flow Switch 1 BSPT Stainless steel paddle Datasheet PDCSY-FS-541.pdf

Datasheets PDCSY-GL-CO-RFG361.pdf, PDCSY-GL-CO-RFG65x.pdf

Tel: +33 (0) 4 78 45 01 23 Fax: +33 (0) 4 78 45 22 33 web: www.distech-controls.eu

Peripheral Programme

PDCSY-GS-AQ1000 Space Air Quality Sensor


The PDCSY-GS-AQ1000 series of volatile organic compound (VOC) sensors are set in our aesthetically pleasing (1000) space housing. Based on tried and tested SnO sensor technology, the new design provides a highly cost-effective answer for monitoring VOCs for indoor air quality, typically for alarm purposes. The sensor element responds to a broad range of contaminants, such as Ammonia (NH) and Hydrogen Sulphide (HS), generated from waste materials in office and home environments. It also has high sensitivity to low concentrations of VOCs such as toluene emitted from wood finishing and construction products. FEATURES Designed to be aesthetically pleasing Blends into the fabric of any building Developed using customer feedback and involvement Fully configurable LCD display option. Please contact the Customer Service Team for more information. SPECIFICATION Active Outputs: Voltage 0-10Vdc or 0-5Vdc Current 4-20mA Optional Passive Outputs: Thermistor Any thermistor type* Setpoint 11-1k/0-10k, linear Override VFC Fan Speed 3 position Resistive 5 position Resistive Power Supply: 0-10Vdc 12 - 26Vac or 16 - 26Vdc 4-20mA 20 - 26Vdc only Ambient: Temperature 0 to 50C (32 to 122F) RH 0 to 95% RH, non-condensing Housing material: ABS (flame retardant) Dimensions: 115 x 85 x 28mm (4.53 x 3.35 x 1.10) Weight: 180g (0.40 lb) Part code PDCSY-GS-AQ1000 -T -SP -MS -FS3 -FS5 -LCD -ACT PDCSY-GASKET Description Space Air Quality Transmitter Suffixes (add to part code) Direct resistive temperature output ** 2-wire, 11-1k/0-10k setpoint Momentary switch 3-speed fan switch 5-speed fan switch Integral LCD display Active Output-Temperature Accessory Insulating gasket (pack of 10) Datasheets PDCSY-GS-AQ1000.pdf ** When using -T option there is no compensation for internal heating. Please allow for this in temperature scaling.

Part code PDCSY-GS-AQ521 PDCSY-DPA

Description Duct Air Quality Transmitter Accessory Duct probe adjustment flange Datasheets PDCSY-GS-AQ521.pdf

PDCSY-GS-CO2

Carbon Dioxide Sensors

This PDCSY-GS-CO2 series uses a non-dispersive infrared sensor for measuring CO2 concentrations, utilising microprocessor based electronics and a unique self-calibration algorithm to improve long-term stability and accuracy. The sensor can be used to ensure adequate ventilation while maximizing energy savings by ventilating at the optimum level, making these ideal for all types of ventilation in commercial buildings, industrial plants, laboratories and public spaces, such as schools. FEATURES Real-time detecting CO2 levels Self-calibration algorithm User selectable outputs with ModBus option 3-colour traffic light LED sets for CO2 levels SPECIFICATION Output 4-20 mA 0-10 VDC (jumper selectable) or ModBus ModBus RS485 19200 bps 15 KV antistatic protection Power supply 4-20 mA 24 VDC 10% 0-10 VDC 24 VAC/DC 10% Max. current 67 mA Accuracy 40 ppm +3% of reading @ 25C Stability < 2% over sensor life Non-linearity < 1% of FS Sensor life 15 years, typical Duct air velocity 0-450 m/min (-D types only) Measurement range 0 to 2000 ppm LED indication 3-colour sets, indicating CO2 levels (optional) Green - optimal, yellow - moderate, red - poor Ambient range Temp. 0 to 50C RH 0 to 95% non-condensing Housing material Flame retardant ABS Dimensions: PDCSY-GS-CO2-D Housing 100 x 80 x 50 mm Probe 125.5 x 40 mm PDCSY-GS-CO2-W Housing 100 x 80 x 28 mm Protection PDCSY-GS-CO2-D IP65 PDCSY-GS-CO2-W IP30 Weight PDCSY-GS-CO2-D 360 g PDCSY-GS-CO2-W 140 g Part code PDCSY-GS-CO2-D Description Duct Mounting Sensors CO2 Sensor CO2 Sensor with Modbus Output Wall Mounting Sensors PDCSY-GS-CO2-W PDCSY-GS-CO2-W-M PDCSY-GS-CO2-W-LED PDCSY-GS-CO2-W-LED-M PDCSY-GS-CO2-W-LED-B CO2 Sensor CO2 Sensor with Modbus Output CO2 Sensor with LED level indication CO2 Sensor with LED indication and Modbus Output CO2 Sensor with LED indication and override button PDCSY-GS-CO2-D-M

PDCSY-GS-AQ521 Duct Air Quality Sensor


Duct air quality transmitter is designed for use in the optimisation of the quantity of fresh air introduced into a building for ventilation purposes. The sensors are sensitive to a range of odours, smoke, solvent gases etc., and provide an output proportional to the mixed gas concentration. This signal can be used to control fresh air fans and dampers according to the ventilation load. In installations where the primary contaminant load is human respiration, it is recommended that a CO transmitter is used. FEATURE Detects particulates as well as gases SPECIFICATION Sensor type: Ambient range: Power supply: Output: Material: Protection: Dimensions: Weight: Tin dioxide film Temperature 0 to 50C (32 to 122F) RH 0 to 100% 24Vac/dc 10% 0 to 10Vdc Housing Flame retard ABS Probe PVC IP65 Housing 57 x 85mm dia. (2.24 x 3.35 dia.) Probe 200 x 25mm (7.87 X 0.98) 300g (0.66 lb)

Datasheets PDCSY-GS-CO2-D.pdf, PDCSY-GS-CO2-W.pdf, PDCSY-GS-CO2-W-LED.pdf

PDCSY-GS-CO2-RHT Carbon Dioxide, RH & T Sensors


Using a non-dispersive infrared sensor for measuring CO2 concentrations and utilising microprocessor based electronics, the unique self-calibration algorithm offers long-term stability and accuracy. They are also fitted with a RH and temperature output, and have an optional LCD with 3-colour traffic light status indication. The sensor can be used to ensure adequate ventilation while maximising energy savings by ventilating at the optimum level, making these ideal for all types of ventilation in commercial buildings, industrial plants, laboratories and public spaces, such as schools.

... buy with confidence - 2-year Warranty


FEATURES Real-time detecting CO2 levels Self-calibration algorithm User selectable outputs with Modbus option 3-colour traffic light LCD status for CO2 levels SPECIFICATION Output 4-20 mA, 0-10 VDC (jumper selectable) or ModBus Modbus RS485 19200 bps, 15 KV antistatic protection Power supply 4-20 mA 24 Vdc 10% 0-10 VDC 24 VAC/DC 10% Max. current 146 mA Sensor life 15 years (-D types), 10 years (-W types), typical Duct air velocity 0-450 m/min (-D types only) 0 to 2000 ppm Measurement ranges CO2 RH 0 to 100% (-D types), 5 to 95% (-W types) Temp. 20 to +60C (-D types), 0 to 50C (-W types) Accuracy CO2 40 ppm +3% of reading @ 22C RH < 3% @ 25C Temp. 0.4C (-D types), 0.5C (-W types) 40 ppm +3% of reading @ 22C Stability: CO2 RH < 3% @ 25C Temp. 0.4C (-D types), 0.5C (-W types) LED indication 3-colour, indicating CO2, RH & Temp. levels (optional) Green optimal (< 1000 ppm) Yellow moderate (1001 to 1400 ppm) Red poor (>1400 ppm) Ambient range Temp. 0 to 50C RH 0 to 95% non-condensing Housing material Flame retardant ABS Dimensions Duct types Housing 100 x 80 x 50 mm Probe 125.5 x 40 mm Wall types Housing 130 x 85 x 36.5 mm Protection Duct types IP54 Wall types IP30 Weight Duct types 360 g Wall types 260 g Part code PDCSY-GS-CO2-RHT-D PDCSY-GS-CO2-RHT-D-LCD PDCSY-GS-CO2-RHT-D-M-LCD Description Duct Mounting Sensors CO2 / RH / T Sensor CO2 / RH / T Sensor with LCD display CO2 / RH / T Sensor with Modbus Output and LCD Display Wall Mounting Sensors PDCSY-GS-CO2-T-W PDCSY-GS-CO2-RHT-W PDCSY-GS-CO2-RHT-W-M PDCSY-GS-CO2-RHT-W-LCD PDCSY-GS-CO2-RHT-W-M-LCD CO2 / T Sensor CO2 / RH / T Sensor CO2 / RH / T Sensor with Modbus Output CO2 / RH / T Sensor with LCD Display CO2 / RH / T Sensor with Modbus Output and LCD Display Part code

Innovative Solutions for Greener Buildings

PDCSY-GS-S-ND10 PDCSY-GS-S-OX25 PDCSY-GS-S-SD20

Description NO2 Nitrogen Dioxide Sensors 0 to 10 ppm 15 to 25% O2 Oxygen Sensor

0.1 ppm 0.1% 0.5 ppm

SO2 Sulphur Dioxide Sensor 0 to 20 ppm

Data sheets PDCSY-GS-S-CM.pdf, PDCSY-GS-S-ND.pdf

PDCSY-GS-CO2-1000

Carbon Dioxide, RH & T Sensors

The new PDCSY-GS-CO2-1000 range of combined CO, Temperature and RH sensors are set in our aesthetically pleasing (1000) space sensor housing. Using a non-dispersive infrared sensor for measuring CO concentrations and utilising microprocessor based electronics, the unique self-calibration algorithm offers long-term stability and accuracy. They are also fitted with a temperature output or RH output. A directly connected passive resistive temperature output is also available, as an alternative to the standard active temperature output. The sensor can be used to ensure adequate ventilation while maximising energy savings by ventilating at the optimum level, making these ideal for all types of ventilation in commercial buildings, industrial plants, laboratories and public spaces, such as schools. FEATURES CO Self-calibration algorithm 0-10Vdc or 4-20mA outputs, with Modbus as standard Up to two analogue outputs Designed to be aesthetically pleasing Blends into the fabric of any building SPECIFICATION Outputs: Power supply: Supply current: Measurement ranges: Optional passive output: Modbus: Sensor life: Accuracy: Stability: Ambient: Housing material Dimensions: Protection: Weight: Part code PDCSY-GS-CO2-1000 PDCSY-GS-CO2-RHT-1000 -T PDCSY-GASKET

Datasheets PDCSY-GS-CO2-RHT-D.pdf, PDCSY-GS-CO2-RHT-W, PDCSY-GS-CO2-T-W

PDCSY-GS-S

Gas Sensor

The PDCSY-GS-S range of 4-20 mA loop powered gas sensors are fitted into a robust housing, to detect the following gases: Carbon monoxide CO Nitrogen dioxide NO2 Oxygen O2 Sulphur dioxide SO2 FEATURES 4-20 mA output Wide supply voltage range (7.5 to 35 VDC) Excellent long term stability Accuracy unaffected by position SPECIFICATION Temp. range 30 to +50C RH range 15 to 90% non-condensing Output 4-20 mA Supply 7.5 to 35 VDC Output impedance 825 Housing material ABS (flame retardant) Protection IP65 (housing only, suitable for internal mounting only) Dimensions 95 x 90 mm dia. Weight 160 g Note: These units are not intended for use in life safety applications.

0-10Vdc, 4-20mA (3-wire) or Modbus 24Vac/dc 50mA maximum, 32mA average CO2 0 to 2000ppm Temperature 0 to 50C (32 to 122F) RH 0 to 100% PTC/NTC Element Any resistive type* 19200bps, 15kV antistatic protection 10 years typical CO2 40ppm +3% of reading Temperature 0.5C (0.9F) RH 3%RH (20 to 80%) CO2 <2% of FS over life of sensor Temperature 0.1C RH 1%RH per year Temperature 0 to 50C (32 to 122F) RH 0 to 95% RH, non-condensing ABS (flame retardant) 115 x 85 x 28mm (4.53 x 3.35 x 1.10) IP30 200g (0.44lb) Description Space CO and Temperature Transmitter Space CO, RH and Temperature Transmitter Suffix (add to part code) Direct resistive temperature output Accessory Insulating gasket (pack 10) Data sheets PDCSY-GS-CO2-1000.pdf

* Notes: 1. -T version uses a thermistor element for direct measurement of temperature. Please specify thermistor type when ordering. 2. When using the -T option, they are not compensated for internal heating. 3. Please see page 73 for Thermistor Types and Compatibility Chart.

Tel: +33 (0) 4 78 45 01 23 Fax: +33 (0) 4 78 45 22 33 web: www.distech-controls.eu

Peripheral Programme

PDCSY-GS-S-CO

Carbon Monoxide Sensors

101 Series

HVAC Basic Drive

The range of CO sensors offers real time detection for Carbon Monoxide measurement. The PDCSY-GS-S-CO-LED range has 6 LED indicator lights which change colour based upon concentration levels. This allows for easy visual awareness of the CO levels, with either a relay or RS485 interface output. A user selectable 0-10Vdc, 4-20mA or optional Modbus output is available with the PDCSY-GS-S-CO-W range. Using a robust long life electrochemical Carbon Monoxide sensor, the PDCSY-GS-S-CO-W is ideal for many applications including underground parking, loading bays and warehouses. The PDCSY-GS-S-CO-M sensor measures CO and temperature with a Modbus output. FEATURES 5 Year sensor lifetime Accurate and reliable 3-Set LED indication (PDCSY-GS-S-CO-LED) User selectable outputs with Modbus option Robust housing for industrial applications (PDCSY-GS-S-CO-W) SECIFICATION Outputs: PDCSY-GS-S-CO-LED PDCSY-GS-S-CO-W PDCSY-GS-S-CO-M Power supply: PDCSY-GS-S-CO-LED PDCSY-GS-S-CO-M PDCSY-GS-S-CO-W Consumption: Measurement range: PDCSY-GS-S-CO-LED PDCSY-GS-S-CO-M PDCSY-GS-S-CO-W Accuracy: PDCSY-GS-S-CO-W Response time: PDCSY-GS-S-CO-LED PDCSY-GS-S-CO-M PDCSY-GS-S-CO-W Modbus RS485: Ambient range: PDCSY-GS-S-CO-LED PDCSY-GS-S-CO-W PDCSY-GS-S-CO-M Housing material: Dimensions: PDCSY-GS-S-CO2-LED PDCSY-GS-S-CO-M PDCSY-GS-S-CO-W PDCSY-Probe Protection: PDCSY-GS-S-CO-LED PDCSY-GS-S-CO-M PDCSY-GS-S-CO-W Weight: PDCSY-GS-S-CO-LED PDCSY-GS-S-CO-M PDCSY-GS-S-CO-W Part code PDCSY-GS-S-CO-LED PDCSY-GS-S-CO-LED-M PDCSY-GS-S-CO-M PDCSY-GS-S-CO-W-K PDCSY-GS-S-CO-W-P PDCSY-GS-S-CO-W-K-M PDCSY-GS-S-CO-W-P-M Relay or RS485 4-20mA(3-wire) 0-10Vdc (jumper selectable) Modbus

PDCSY-GS-S-COLED types

PDCSY-GS-SCO-W types

The 101 HVAC Basic series is dedicated to your air handling units and pumping applications. Moreover, this high reliability drive offers the best price/performances ratio for HVAC applications. Thanks to the last power electronics technology, the 101 HVAC Basic is the most compact drive in its category and provides the main functions for standard HVAC applications. Its modular structure makes it a profitable and reliable drive for integrations in Building Management Systems or to programmable controllers. Indeed, regardless its reduced dimensions, the drive can operate permanently even in hard working and challenging conditions, even with long motor cables and ambient temperatures up to 50C. The optimized output and smart cooling technology allow for a compact and userfriendly conception, controlled through an ergonomics interface, providing notably complete information on energy consumption. FEATURES High output >98% Alphanumeric display (option) Automatic energy optimization Automatic adjustment to the engine Easy to use 7 languages programming Quick Menu function for fast installation Minimum maintenance PI regulator Configuration wizard

18 to 38Vac/dc 18 to 38Vac/dc 4-20mA 24Vdc 10% 0-10Vdc 24Vac/dc 10% 2.8W max.

PDCSY-GS-S-CO-M types

SPECIFICATION Power supply Output voltage Digital input Logic PNP or NPN Analog inputs Analog outputs 380 to 480 VCA 10% 50-60 Hz 0-100% of power supply 4 programmable digital inputs 0-24 V 2 analog inputs Voltage or current mode Voltage level 0 V to +10 V (possible scaling) Current level 0/4 to 20 mA (possible scaling) 2 programmable analog outputs (can be used as digital outputs) Analog current range 0/4 20 mA Relay outputs 2 programmable relay outputs (240 VCA, 2 A and 400 VCA, 2 A) Communication BACnet MS/TP (standard) ModBus RTU (standard) Ambient Operating temperature -10 to +50C Altitude 0 to 2000 m Protection IP20 Compliance EN 61800-3

0 to 500ppm 0 to 500ppm 0 to 100ppm/0 to 1000ppm selectable <1ppm, @ 20C (68F) 5C (9F), 15 to 85%RH <5 minutes for 90% step change <5 minutes for 90% step change <60 seconds 19200bps, 15kV antistatic protection Temp. 0 to 70C (32 to 158F) RH 0 to 95%, non-condensing Temp. 0 to 50C (32 to 122F) RH 0 to 99%, non-condensing Temperature 0 - 50C (32fo22F) RH 5 to 95%, non-condensing Flame retardant ABS 100 x 80 x 28mm (3.94 x 3.15 x 1.10) 100 x 80 x 28mm (3.94 x 3.15 x 1.10) 100 x 80 x 50mm (3.94 x 3.15 x 1.97) 69 x 26mm dia. (2.72 x 1.02 dia.) IP30 IP30 IP54 190g (0.42 lb) 190g (0.42 lb) 260g (0.57 lb)

Part code 131L9861 131L9862 131L9863 131L9864 131L9865 131L9866 131L9867 131L9868 131L9869 131L9870 131L9871 131L9872 132B0200

Description CO Sensor with LED Indication and Relay Output CO Sensor with LED Indication and RS485 Output CO & Temperature Sensor, 0-500ppm with Modbus Output CO Sensor, 0-100ppm CO Sensor, 0-1000ppm CO Sensor, 0-100ppm with Modbus Output CO Sensor, 0-1000ppm

Output (kW) 0.37 0.75 1.5 2.2 3.0 4,0 5.5 7.5 11 15 18 22

Current (40C) Current (50C) (A) (A) 1.2 1 2.2 1.9 3.7 3.7 5,3 4.9 7.2 6.3 9.1 8.4 12 10.9 15.5 14 23 20.9 31 28 37 34.1 42.5/44 38/35.2

Dimensions (mm) 195 x 75 x 168 195 x 75 x 168 195 x 75 x 168 227 x 90 x 190 227 x 90 x 190 227 x 90 x 190 255 x 100 x 206 255 x 100 x 206 296 x 165 x 241 296 x 165 x 241 334 x 150 x 255 334 x 150 x 255

Programming Keyboard Option

Data sheets PDCSY-GS-S-CO-LED.pdf, PDCSY-GS-S-CO-M.pdf, PDCSY-GS-S-CO-W.pdf Note: These units are not intended for use in life safety applications.

10

Innovative Solutions for Greener Buildings

102 Series

HVAC Drive

The 102 HVAC Drive embeds the latest functional and electronics innovations to contribute to building energy efficiency while reducing operating costs and CO2 footprint. Advancements in energy monitoring, trending, system maintenance and operation are combined with a modular platform to make the drive easy to operate while feeding back all the operation information you need. FEATURES High output > 98% Graphical display Automatic energy optimization Automatic adjustment to the motor Easy to use 7 languages programming Wide choice of HVAC protocols for BMS connectivity Specific features for fan, pumps, and compressor Minimum maintenance 4 PID self-tuning regulators Configuration wizard

Part code 131U1466 131B3532 131B5470 131U1467 131U1469 131B4214 131B5471 131U1470 131U1482 131B4215 131B5472 131U1483 131U1484 131B4216 131B5473 131B4230 131B5488 131B3611 131B5474 131B4231 131B5489 131F0426 131F8307 131B1275 131B1276 131F6625 131F8308 131B4979 131B5480 131F5456 131G0433 131B4980 131B5481 131F6626 131F9921 131B4269 131B5482 131F5454 131F9926 131B4270 131B5479 131F5451 131F9931 131B7009 131B6976 131F6627 131F9936 131B7016 131B7017 131F5449 131F9941 131B7026 131B7027 131F6628 131F9946 131B8594 131B9364 131F5448 131F9951 131B8596 131B1568 -AG -AJ

IP IP55 IP20 IP20 IP55 IP55 IP20 IP20 IP55 IP55 IP20 IP20 IP55 IP55 IP20 IP20 IP55 IP55 IP20 IP20 IP55 IP55 IP20 IP20 IP55 IP55 IP20 IP20 IP55 IP55 IP20 IP20 IP55 IP55 IP20 IP20 IP55 IP55 IP20 IP20 IP55 IP55 IP20 IP20 IP55 IP55 IP20 IP20 IP55 IP55 IP20 IP20 IP55 IP55 IP20 IP20 IP55 IP55 IP20 IP20 IP55 IP55

Output (kW) 1,5 2,2 2,2 2,2 2,2 3 3 3 3 4 4 4 4 5,5 5,5 5,5 5,5 7,5 7,5 7,5 7,5 11 11 11 11 15 15 15 15 18,5 18,5 18,5 18,5 22 22 22 22 30 30 30 30 37 37 37 37 45 45 45 45 55 55 55 55 75 75 75 75 90 90 90 90

Current (A) 50C 440 V 4,1 5,6 5,6 5,6 5,6 7,2 7,2 7,2 7,2 10 10 10 10 13 13 13 13 16 16 16 16 24 24 24 24 32 32 32 32 37,5 37,5 37,5 37,5 44 44 44 44 61 61 61 61 73 73 73 73 90 90 90 90 106 106 106 106 147 147 147 147 177 177 177 177

RFI Filter Class A2 A1/B A2 A1/B A2 A1/B A2 A1/B A2 A1/B A2 A1/B A2 A1/B A2 A1/B A2 A1/B A2 A1/B A2 A1/B A2 A1/B A2 A1/B A2 A1/B A2 A1/B A2 A1/B A2 A1/B A2 A1/B A2 A1/B A2 A1/B A2 A1/B A2 A1/B A2 A1/B A2 A1/B A2 A1/B A2 A1/B A2 A1/B A2 A1/B A2 A1/B A2 A1/B A2

Dimensions (mm) 420 x 242 x 195 268 x 90 x 205 268 x 90 x 205 420 x 242 x 195 420 x 242 x 195 268 x 90 x 205 268 x 90 x 205 420 x 242 x 195 420 x 242 x 195 268 x 90 x 205 268 x 90 x 205 420 x 242 x 195 420 x 242 x 195 268 x 130 x 205 268 x 130 x 205 420 x 242 x 195 420 x 242 x 195 268 x 130 x 205 268 x 130 x 205 420 x 242 x 195 420 x 242 x 195 399 x 165 x 249 399 x 165 x 249 480 x 242 x 260 480 x 242 x 260 399 x 165 x 249 399 x 165 x 249 480 x 242 x 260 480 x 242 x 260 399 x 165 x 249 399 x 165 x 249 480 x 242 x 260 480 x 242 x 260 520 x 230 x 242 520 x 230 x 242 650 x 242 x 260 650 x 242 x 260 520 x 230 x 242 520 x 230 x 242 650 x 242 x 260 650 x 242 x 260 520 x 242 x 230 520 x 242 x 230 680 x 310 x 308 680 x 310 x 308 550 x 333 x 308 550 x 333 x 308 680 x 310 x 308 680 x 310 x 308 550 x 333 x 308 550 x 333 x 308 680 x 310 x 308 680 x 310 x 308 660 x 333 x 370 660 x 333 x 370 770 x 335 x 370 770 x 335 x 370 660 x 333 x 370 660 x 333 x 370 770 x 335 x 370 770 x 335 x 370

APPLICATIONS Pumps Vital water supply can be ensured in case of leak or pipe break. Thermical overload is for example avoided by decreasing the speed, and the water supply is ensured with a reduced rating. Aiming at energy savings, the drive detects low flow situations by increasing the system pressure, then stops the motor. It restarts automatically when the pressure reaches the lowest setpoint. Fans The fire protection mode prevents the drive from stopping in case of critical situation. It keeps driving the machine as long as possible. Thanks to its modular structure, the 102 HVAC Drive is perfectly suitable for integration in Building Management Systems or with stand-alone programmable controllers. It avoids the bandwidths with which the fan generates resonance in the fan system, and therfore improves comfort in the building. In case of fire, the 102 HVAC Drive maintains a higher atmospheric pessure in staircases than in the other parts of the building so as to keep the smoke down in escape routes. SPECIFICATION Power supply 3-phase, 380 to 480 VCA 10% 50/60 Hz Output voltage 0 to 100% of supply voltage Output frequency 0-1000 Hz Programming Detachable graphical user interface Digital input 6 programmable digital inputs (2 can be used as digital outputs) Logic PNP or NPN Voltage 0-24 V Pulse inputs 2 programmable pulse input (uses digital inputs) Voltage 0-24 V (PNP logic) Pulse inputs accuracy 0.1-110 kHz Analog inputs 2 analog inputs Voltage or current modes Voltage 0 to +10 V (possible scaling) Current 0/4 to 20 mA (possible scaling) Analog outputs 1 programmable analog outputs Analog current range 0/4 20 mA Relay outputs 2 programmable relay outputs (240 VCA, 2 A and 400 VCA, 2 A) Communications ModBus RTU (standard) BACnet MS/TP (standard) Enhanced BACnet MS/TP (option) LONWORKS (option) Ambient Operating temperature -10 to +50C Altitude from 0 to 2000 m (operational) Protection IP20 / IP55 depending on models Compliance EN 61000-3-12, EMC

Part code 131B3526 131B5468 131U1463 131U1464 131B4206 131B5469 131U1465

IP IP20 IP20 IP55 IP55 IP20 IP20 IP55

Output (kW) 1,1 1,1 1,1 1,1 1,5 1,5 1,5

Current (A) 50C 440 V 3 3 3 3 4,1 4,1 4,1

RFI Filter Class A1/B A2 A1/B A2 A1/B A2 A1/B

Dimensions (mm) 268 x 90 x 205 268 x 90 x 205 420 x 242 x 195 420 x 242 x 195 268 x 90 x 205 268 x 90 x 205 420 x 242 x 195

Options LONWORKS FT-10 OPtION ENHANCeD BACNet MS/TP OPtION

Tel: +33 (0) 4 78 45 01 23 Fax: +33 (0) 4 78 45 22 33 web: www.distech-controls.eu

11

Peripheral Programme

PDCSY-IO-ABM4

Analogue Override Module

PDCSY-IO-AUD

Raise/Lower to Analogue Module

Intended for applications which require independent manual override of analogue output channels from a BMS controller, as a fail-safe in the event of controller failure. Enables actuators to be manually overridden from the panel where local access is difficult. Also useful for commissioning or temporary control of plant prior to controller installation. FEATURES 4 x 0-10 VDC channels Hand/off/auto link selectable Manual adjustment of output signal 24 VAC/DC powered Up to four outputs to be controlled from one input Direct or buffered output signals SPECIFICATION Input signals Output signals Max. output current Power supply Max. supply current Fused output Fuse Ambient range Dimensions Weight Part code PDCSY-IO-ABM4 0-10 VDC 0-10 VDC direct or buffered 20 mA per channel in buffered mode 24 VAC/DC 15% AC supply 260 mA DC supply 115 mA 24 VAC @ 8 A 8 A max. 10 to +50C 104 x 106 x 70 mm 110 g Description Analogue Override Module - 4-channel Module Datasheet PDCSY-IO-ABM4.pdf

The PDCSY-IO-AUD accepts a raise/lower relay signal and provides a 0-10 VDC output. Additional features include Hand/Off/Auto jumper for manual override, LED status indication and selectable hysteresis. FEATURES Field adjustable output Manual override potentiometer Field selectable rate of change 255 step resolution Current or voltage output LED status indicators No wrap around Relay, transistor, or triac input SPECIFICATION Input signal Input ranges Output signal Resolution Power supply Ambient range Storage temp Dimensions Weight Part code PDCSY-IO-AUD Relay contact, transistor, triac, 24 VAC, 50/60 Hz 45, 60, 120 or 240 seconds selectable Voltage 0-10 VDC 3.3 k min. Current 4-20 mA 750 max. 255 steps AC 21.6 to 28 VAC @ 50/60 Hz DC 24 to 35 VDC Consumption 208 mA max. Temperature 0 to 50C Humidity 10 to 95% RH non-condensing 30 to +65C 96 x 58 x 30 mm 150 g Description Raise / Lower to Analogue Module Datasheet PDCSY-IO-AUD.pdf

PDCSY-IO-ARM

Analogue Rescaling Module

PDCSY-IO-DIM

Digital Input Multiplexers

This module can accept either a voltage or current input which can be rescaled to either a voltage or current output. A range of preset values are link selectable. Fine adjustments can be achieved using trimming potentiometers. The PDCSY-IO-ARM can also reverse an input signal. FEATURES Field selectable ranges Reverse or normal output LED power indication DIN-rail mounting Note: The PDCSY-IO-ARM does not isolate the input signal from the output signal. APPLICATIONS Voltage to current conversion Current to voltage conversion Reduce or expand sensor ranges Reverse control signals SPECIFICATION Input signals Output signals Power supply Ambient range Dimensions Weight Part code PDCSY-IO-ARM Voltage 0 to 35 VDC max. Current 0 to 44 mA max. Voltage 0.25 to 20 VDC max. Current 1 to 44 mA max. 24 VAC/DC 10%, 200mA max. 10 to +50C, 10 to 95% RH 93 x 60 x 40 mm 60 g Description Analogue Rescaling Module Datasheet PDCSY-IO-ARM.pdf

These modules are intended for use with BMS controllers to expand their input capacity by multiplexing four or six digital signals or 4 x 24 VAC/DC inputs into a single analogue controller unit. Each combination of input states corresponds to an analogue value from the PDCSY-IO-DIM4 and PDCSY-IO-DIM6 which can be decoded into four or six digital status bits. FEATURES Fault finding LED indication Input status indication Input status simulation Expands controller input capacity Self calibrating output SPECIFICATION Inputs VFC, 24 VAC or 24 VDC Outputs 0-10 VDC into 2 k impedance 4-20 mA into 500 max. Power supply 24 VAC 15% @ 50 Hz or 24 VDC +15% 6% Current 35 mA max. voltage output mode 55 mA max. current output mode LED indication Supply OK, supply voltage low, supply voltage high, current output (4-20 mA output only) Ambient range Temp. 10 to +50C RH 0 to 80% non-condensing Dimensions PDCSY-IO-DIM4 75 x 55 x 42 mm PDCSY-IO-DIM6 75 x 75 x 42 mm Weight PDCSY-IO-DIM4 80 g PDCSY-IO-DIM6 100 g Part code PDCSY-IO-DIM4 PDCSY-IO-DIM6 Description 4 x VFC or 24 VAC/DC inputs, selectable output 6 x VFC or 24 VAC/DC inputs, selectable output Datasheets PDCSY-IO-DIM4.pdf, PDCSY-IO-DIM6.pdf

12

Innovative Solutions for Greener Buildings

PDCSY-IO-EPC

Electro-pneumatic Converters

PDCSY-IO-RM1

Single Relay Modules

Intended for use with BMS controllers to convert an analogue electrical control signal (either voltage or current loop) to a proportional pneumatic output. Link selection of input ranges, voltage output feedback signal, and manual override are fitted as standard. FEATURES Four input ranges, link selectable Manual override Gauge indication 0-5 VDC, 0-10 VDC, 0-15 VDC, 0-20 mA Feedback signal 0-5 VDC = 0-15 psig Output pressure Link selectable 0-10, 0-15 or 0-20 psig Accuracy < 1.5% full scale Power supply 24 VDC +10% 5% (< 0.2% ripple) or 24 VAC 10% @ 50/60 Hz @ 160 mA max. Air supply 25 psig max. 18 psig min. Pressure connections Brass barbs for 6.25 mm (14 o/d, 18 i/d) tubing Ambient range Temperature 0 to 50C Humidity 5 to 95% RH non-condensing Dimensions 104 x 73 x 70 mm Weight 320 g Note: If power is lost to the dual valve PDCSY-IO-EPC2-G it will not exhaust any additional air from the branch line, but the single valve PDCSY-IO-EPC-G will continue to bleed through the orifice until branch pressure is 0 psig. Part code PDCSY-IO-EPC-G PDCSY-IO-EPC2-G Description 1 Valve + gauge 2 Valves + gauge Datasheets PDCSY-IO-EPC-G.pdf, PDCSY-IO-EPC2-G.pdf SPECIFICATION Input signals

A range of relays for use with BMS controllers for switching plant and isolation of input signals. SPECIFICATION Relay clip Ambient range Dimensions Input signals Output contacts Weight Auto eject type supplied 10 to +50C 55 x 12 x 50 mm PDCSY-IO-RM1-12DC 10 VDC PDCSY-IO-RM1-24DC 24 VDC PDCSY-IO-RM1-24AC 24 VAC PDCSY-IO-RM1-240AC 230 VAC PDCSY-IO-RM1-12DC 8 A resistive PDCSY-IO-RM1-24DC 8 A resistive PDCSY-IO-RM1-24AC 12 A resistive PDCSY-IO-RM1-240AC 12 A resistive 60 g

Part code PDCSY-IO-RM1-12DC PDCSY-IO-RM1-24DC PDCSY-IO-RM1-24AC PDCSY-IO-RM1-240AC

Description Single Relay, 12Vdc Module Single Relay, 24Vdc Module Single Relay, 12Vac Module Single Relay, 24Vac Module Datasheets PDCSY-IO-RM1.pdf

PDCSY-IO-RM2

2-stage Relay Module

This module is intended for use with BMS controllers to convert an analogue control output to a raise/ lower, high/ low or binary relay output pair. Applications include the control of raise/lower valve and damper actuators, and pump changeover. LEDs indicate correct operation and Hand/Off/Auto jumpers ease commissioning. Low current draw from 0-10 VDC controller output means that the PDCSY-IO-RM2 can work successfully with most BEMS controllers. FEATURES Fault finding LED indication Relay status LED indication Link selectable raise/lower, hi/low or binary modes On/Off/Auto links for ease of commissioning SPECIFICATION Input signal 0 to 10 VDC, 1 mA min. into 22 k impedance Output contacts 8 A @ 230 VAC (resistive load) Power supply 24 VAC 15% @ 50 Hz or 24 VDC + 15% 6%, 65 mA max. Hystereris 0.2 VDC about switching points Operating modes Hi/Lo, one raise/lower pair and binary LED indication Supply OK, supply voltage low, supply voltage high, relay status, hi-input voltage, incorrect input mode jumper selection, low input voltage (only in 2-10 VDC mode) Ambient range Temp. 10 to +50C, RH 0 to 80% non-condensing Dimensions 72 x 49.5 x 55 mm Weight 100 g Part code PDCSY-IO-RM2 Description 2-stage Relay Module Datasheet PDCSY-IO-RM2.pdf

PDCSY-IO-IIM

Input Isolation Modules

Intended for use with BMS controllers wherever the output signal requires isolation from supply ground. The PDCSY-IO-IIM accepts either a current loop or voltage input. The module is powered by 24Vac and the output 0V is floating with respect to the input and supply ground. FEATURES 4-20 mA, 0-20 mA, 0-5 VDC, or 0-10 VDC input Full opto-isolation between inputs and output SPECIFICATION Input signal PDCSY-IO-IIM-I 4-20 mA (changeable to 0-20 mA) PDCSY-IO-IIM-V 0-5 VDC into 100 k, 0-10 VDC into 200 k Output signal PDCSY-IO-IIM-I 0-10 VDC PDCSY-IO-IIM-V 0-5 VDC or 0-10 VDC Output current 20 mA max Supply 24 VAC +15% 10% Typical current 80 mA + load Power supply to sensor 24 VDC 5% Max. sensor current 100 mA Ambient range 10 to +50C Dimensions 75 x 102 x 65 mm Weight 325 g Part code PDCSY-IO-IIM-I PDCSY-IO-IIM-V Description 4-20 mA Input Isolation Module 0-5 / 0-10 VDC Input Isolation Module Datasheet PDCSY-IO-IIM.pdf

Tel: +33 (0) 4 78 45 01 23 Fax: +33 (0) 4 78 45 22 33 web: www.distech-controls.eu

13

Peripheral Programme

PDCSY-IO-RM3

3-stage Relay Module

PDCSY-IO-RM8

8-stage Relay Module

The PDCSY-IO-RM3 is designed for use with BMS controllers to convert an analogue control output to a binary, heat/cool, staged or sequenced relay modes. LEDs indicate correct operation and Hand/Off/Auto jumpers ease commissioning. Low current draw from 0-10 VDC controller output means that the PDCSYIO-RM3 can work successfully with most BEMS controllers. FEATURES Fault finding LED indication Relay status LED indication Link selectable binary, heat/cool, staged or sequenced modes On/Off/Auto links for ease of commissioning SPECIFICATION Input signal Output contacts Power supply Time delay Operating modes Ambient range Dimensions Weight Part code PDCSY-IO-RM3 0 to 10 VDC < 2 mA 8 A @ 230 VAC (resistive load) 24 VAC/DC 12% at 60 mA max. Adjustable from 0-60 seconds 3-stage, heat/cool, step, binary 10 to +50C 72 x 64 x 55 mm 140 g Description 3-stage Relay Module Datasheet PDCSY-IO-RM3.pdf

These modules are used to convert a 0-10 VDC input to an 8-stage relay output. Link selection of operating mode enables the module to act either as eight stages of switching, as an eight output sequencer, or in a combination of the two modes. FEATURES Fault finding LED indication Relay status LED indication On/Off/Auto links for ease of commissioning Link selectable staged or sequenced modes SPECIFICATION Input signal Output contacts Power supply Hysteresis Operating modes Ambient range Dimensions Weight 0 to 10 VDC <1 mA @ 10 k 8 A @ 230 VAC (resistive load) 24 VAC/DC 15% @ 50 Hz (250 mA max.) 0.12 VDC 0.06 VDC Staged, sequenced or combination 0 to 40C, 0 to 80% RH non-condensing 72 x 156 x 55 mm 300 g

Part code PDCSY-IO-RM8

Description 8-stage Relay Module Datasheet PDCSY-IO-RM8.pdf

PDCSY-IO-RM4

4-stage Relay Module

PDCSY-IO-RMA

Relay Module Adjustable

The PDCSY-IO-RM4 enables a single 0-10 VDC analogue output from a BMS controller to switch four digital outputs independently, in one of three different modes, and requires < 1 mA input. FEATURES Fault finding LED indication Relay status LED indication On/Off/Auto links for ease of commissioning Link selectable binary, staged or sequenced modes SPECIFICATION Input signal Input impedance Output contacts Power supply Power consumption Ambient range Dimensions Weight 0 to 10 VDC < 1 mA Approx. 11 k 8 A @ 230 VAC (resistive load) 24 VAC/DC 15% @ 50 Hz 100 mA max. 0 to 40C, 0 to 80% RH non-condensing 72 x 82 x 55 mm 200 g

The PDCSY-IO-RMA accepts a 0-10 VDC signal and provides an SPDT relay output with individually adjustable ON and OFF switching points. Additional features include Hand/Off/Auto jumper for manual override, LED status indication and a jumper to lock the settings when the desired switching points have been set. A 0-10 VDC out, which mimics the input control signal, is available to daisy-chain modules from the same BMS controller output. FEATURES Fault finding LED indication Relay status LED indication LED status indication On/Off/Auto links for ease of commissioning 8 A relay and 0-10Vdc output 24 VAC/DC powered Jumper for locking settings ON and OFF points individually adjustable SPECIFICATION Input signal 0 to 10 VDC, 1 mA min. into 22 K impedance Output signal Relay 8 A @ 230 VAC (resistive load) Voltage 0 to 10 VDC Power supply 24 VAC 5% @ 50 Hz or 24 VDC +15% 6%, 45 mA max. Ambient range 10 to +40C, 0-80% non-condensing Dimensions 72 x 49.5 x 55 mm Weight 82 g

Part code PDCSY-IO-RM4

Description 4-stage Relay Module Datasheet PDCSY-IO-RM4.pdf

Part code PDCSY-IO-RMA

Description Adjustable Switching Point Relay Module Datasheet PDCSY-IO-RMA.pdf

14

Innovative Solutions for Greener Buildings

PDCSY-LS-541

Float Switch

PDCSY-LS-FL

Liquid Level Float Switches

The PDCSY-LS-541 is intended to monitor the liquid level in a tank or vessel and provides a switched output for local alarm, pump or valve control. The differential between switching is equivalent to approximately 15 mm. The unit mounts into 1 BSPT female boss. Access is not required to the inside of the tank. SPECIFICATION Mounting Media Operation Operating temp Operating pressure Materials Switch rating Protection Dimensions Weight Part code PDCSY-LS-541 1 BSPT boss Non-aggressive fluids with specific gravity > 0.75 For high or low level Ambient 40 to +85C, media 85C max. 5 bar max. Float Acrylic Rod Brass Bellows Phosphor bronze, Enclosure ABS flame retardant 15 (8) A SPDT @ 230 VAC, VFC IP65 Housing 113.5 x 65 x 62 mm Float & rod 200 x 26 mm dia. max. 300 g Description 1 BSPT Float Switch(horizontal mount) Datasheet PDCSY-LS-541.pdf

The PDCSY-LS-FL series is a range of Level Switches suitable for single or multilevel applications where access is only available from the top surface or where multiple level sensing is desired from a single penetration. Units consist of a float, which is suspended from a weighted cable. As the liquid level changes, the float follows the surface level, at the same time tilting due to its weighted restraint. Inside the float are a number of micro switches which trigger as the float tips. SPECIFICATION Switch rating Std. cable length Min. switching level difference Max. std. switching level diff Materials of construction Min. fluid S.G. Ambient temperature Max. ext. pressure Protection Dimensions Weight 6 A @ 240 VAC 5m 250 mm 1200 mm Polypropylene & PVC 0.7 0 to 55C 200 kPa IP68 170 x 155 mm 1.5 kg

Note: Other types are available on request. Part code PDCSY-LS-FL-1H PDCSY-LS-FL-1L PDCSY-LS-FL-2H PDCSY-LS-FL-2L PDCSY-LS-FL-2LH Description Liquid Level Float Switch - High Level Alarm Liquid Level Float Switch - Low Level Liquid Level Float Switch - Emptying Pump Control Liquid Level Float Switch - Filling Pump Liquid Level Float Switch - High & Low Level Alarm Datasheet PDCSY-LS-FL.pdf Please contact the Customer Services Team for more information.

PDCSY-LS-CAP

Capacitance Level Sensors

These sensors are designed for level measurement in tanks or sumps providing a 4-20 mA output relating to the level of fluid in the tank. The PDCSY-LS-CAP1 is suitable for conducting liquids such as water whilst the PDCSY-LS-CAP2 is designed for use with clean, low viscosity non-conducting liquids such as oil. Both types consist of two concentric elements, an inner probe and an outer tube. Fluid rises in the cavity between the two concentric elements and the changes in capacitance are transposed into an analogue 4-20 mA output signal. FEATURES Suitable for a wide range of media Easy in-situ range adjustment 4-20 mA output No moving parts Unaffected by pressure or vacuum SPECIFICATION Output Supply Insertion length Process connection Process temperature Ambient temperature Max. pressure Electrode insulation Termination housing Protection Weight 4-20 mA 20 to 38 VDC 0.5 to 3 m variants 1 BSP 100C max 20 to +60C 20 bar @ 20C Polypropylene ABS IP65 8.24 kg max.

PDCSY-LS-AFS

Automatic Float Switch

The PDCSY-LS-AFS is designed for simple reliable water level control. The float switch can be used to control a pump for either tank filling or tank emptying (a high or low level cut-out). It is easily achieved by positioning the float stops on the cord. The electrical connections are easily made inside the housing, via the terminal strip. Two M20 cable glands are provided for use with suitable conduit. FEATURES Reliable Easy to install Easy to adjust Simple wiring SPECIFICATION Max. switching voltage 250 VAC Current rating Resistive 20 A Inductive 8A Float operating range Maximum 700 mm Minimum 50 mm Material Housing & float Polypropylene Weights Brass Cord Nylon Ambient temp. range 0 to 50C Media temperature 4 to 50C Protection IP22 Weight 560 g

Part code PDCSY-LS-CAP1-0.5 PDCSY-LS-CAP1-1.0 PDCSY-LS-CAP1-1.5 PDCSY-LS-CAP1-2.0 PDCSY-LS-CAP1-2.5 PDCSY-LS-CAP1-3.0 PDCSY-LS-CAP2-0.5 PDCSY-LS-CAP2-1.0 PDCSY-LS-CAP2-1.5 PDCSY-LS-CAP2-2.0 PDCSY-LS-CAP2-2.5 PDCSY-LS-CAP2-3.0

Description Sensors for Conducting Liquids Capacitance level sensor - 0.5 m probe Capacitance level sensor - 1.0 m probe Capacitance level sensor - 1.5 m probe Capacitance level sensor - 2.0 m probe Capacitance level sensor - 2.5 m probe Capacitance level sensor - 3.0 m probe Sensors for Non-conducting Liquids Capacitance level sensor - 0.5 m probe Capacitance level sensor - 1.0 m probe Capacitance level sensor - 1.5 m probe Capacitance level sensor - 2.0 m probe Capacitance level sensor - 2.5 m probe Capacitance level sensor - 3.0 m probe Datasheet PDCSY-LS-CAP.pdf

Part code PDCSY-LS-AFS

Description Automatic Float switch Datasheet PDCSY-LS-AFS.pdf

Tel: +33 (0) 4 78 45 01 23 Fax: +33 (0) 4 78 45 22 33 web: www.distech-controls.eu

15

Peripheral Programme

PDCSY-LS-S

Side Mounting Liquid Level Switches

PDCSY-LS-MC

Ultrasonic Level Sensor

A range of Level Switches designed for high and low liquid level detection in tanks and vessels. Units consist of a lever arm reed switch assembly and a tank fixing assembly. Type 1 switches fit from the inside of the tank and tighten on to a back nut whilst the type 2 switches mount from the outside into a tapered boss. FEATURES Low cost solution Stainless steel version suitable for a wide range of fluids SPECIFICATION Max switching voltage Max switching current Temperature range Housing material Tank fixing Weight Part code PDCSY-LS-SN1 PDCSY-LS-SN2 PDCSY-LS-SS1 PDCSY-LS-SS2 SN type 230 VAC / 200 VDC SS type 300 VAC / 350 VDC SN type 0.5 A SS type 1 A SN type 20 to +80C SS type 20 to +120C SN type Polypropylene SS type Stainless steel 316 SN1 & SS1 M16 back nut SN2 1/2 NPT SS2 1/2 PF 60 g max.

The PDCSY-LS-MC is an Ultrasonic Level Transmitter for measurement of liquids in tanks or sumps. The 4-20 mA output represents the distance between the surface of the liquid being detected and the sensor. The PDCSY-LS-MC has an integral LCD display, three push buttons under the lid for security, and just eight parameters to set making it one of the simplest ultrasonic level transmitters to calibrate and use. FEATURES IP67 housing 12 to 30 VDC (2-wire loop) power supply Fast speed of response, as much as 10 m per minute Locking nut supplied SPECIFICATION Measurement range Output Supply Load impedance Display Resolution Accuracy (measured range) Process connection Temperature range Material Dimensions Protection Weight Part code PDCSY-LS-MC PDCSY-LS-NUT PDCSY-LS-FK 0.3 m to 8 m 4-20 mA 12 to 30 VDC loop powered 750 max. Integral 4-digit LCD Better than 1mm < 1.0 mm 5mm > 1.0 mm 0.5% of measured distance 2 BSPT 20 to +70C Transducer PVDF Housing Glass filled nylon 205.5 x 141 mm overall IP67 1.25 kg

Description Polypropylene Float Switches Side Mounting Liquid Level Switch - Internal fixing to M16 back nut Side Mounting Liquid Level Switch - 1/2 NPT external fixing Stainless Steel Float Switches Side Mounting Liquid Level Switch - Internal fixing to M16 back nut Side Mounting Liquid Level Switch - 1/2 PF external fixing Datasheet PDCSY-LS-S.pdf

Description Ultrasonic Level Sensor Accessories Additional fixing nut Adaptor flange for LS-UL3 fixing Datasheet PDCSY-LS-MC.pdf

PDCSY-LS-TM

Top Mounting Liquid Level Switch PDCSY-MG-G Gas Meters (with pulsed output)

The PDCSY-LS-TM is an easy to install Top Mounting Level Switch, and has a reversible float so that it can be used for either high or low level alarms. The float is suspended from a 5 metre PVC cable with a polyethylene weight and is fully submersible and adjustable. FEATURES Low cost Easy to install Reliable switching SPECIFICATION Switch rating Contact Material Tank fixing Cable length Specific gravity Max. pressure Operating temp Dimensions Weight Part code PDCSY-LS-TM 0.5 A @ 240 VAC / 200 VDC, SPST N/O, reversible to N/C Cable PVC Float Nylon Weight Polyethylene 11/4 BSP 5m 0.8 4 kg/cm2 20 to 80C 94 x 25 mm dia. 280 g Description Reversible Top Mounting Level Switch Datasheet PDCSY-LS-TM.pdf

Our range of Diaphragm Gas Meters use proven, reliable technology to measure the volume of gas used and then send a pulsed signal to a BMS system. FEATURES Diaphragm type All meters include pulsed output SPECIFICATION Max. pressure Material Pulsed output specification Pulse value Max. load current Max. switching voltage Max. contact rating Switch actuating time Connection type Lead length Conformity Ambient temperature Weight Part code PDCSY-MG-G4 PDCSY-MG-G6 PDCSY-MG-G10 PDCSY-MG-G16 PDCSY-MG-G25 PDCSY-MG-G40 PDCSY-MG-G65 PDCSY-MG-G4 to G10 500mbar PDCSY-MG-G16 to G65 200mbar Epoxy coated steel PDCSY-MG-G4 to G10 0.01m3 per pulse PDCSY-MG-G16 to G65 0.1m3 per pulse 100 mA 24 VDC 0.6 W 0.3 s 4-core flying lead 2m EEC 71/318, UNI-CIG 7987/7988 norms, OIML Regulations 0 to 40C 90 kg max.

Description Gas Meter 1 screwed 6 m3/h Gas Meter 1 screwed 10 m3/h Gas Meter 1 screwed 16 m3/h Gas Meter 1 screwed 25 m3/h Gas Meter 1 screwed 40 m3/h Gas Meter 100 mm Flanged 40 m3/h Gas Meter 100 mm Flanged 65 m3/h Datasheet PDCSY-MG-G.pdf

16

Innovative Solutions for Greener Buildings

An Introduction to Flow Parts for Metering


Distech offer flow parts for two distinct applications. FLOW PARTS FOR WATER denoted in the Distech catalogue as water meters - are used specifically for sanitary water only, i.e. water without additives or chemical treatment, and are designed for non-continuous flow, such as domestic cold and hot water supplies. The total daily flow should not exceed 3 hours, over a 6 year period. Volumetric flows higher than this can lead to increased wear in the bearings of the impellor, causing inaccuracies in reading. Note also that water meters have a narrow fluid temperature range, typically between 0C to +90C for hot water meters and 0C to +30C for cold water meters. FLOW PARTS FOR HEATING denoted in the Distech catalogue as flow sensors can be used with chemically treated water, and are designed for continuous or very high duty cycle flow conditions typically found in hot water heating systems. Flow sensors have a wider fluid temperature range than water meters, typically between 0C to +120C. Note: Because of these distinct differences, only flow parts designed specifically for heat metering should be used for heat metering applications. Although water meters can, in theory, be used for heat meter applications, we cannot warranty water meters if used in this manner. DEFINITIONS: QS, the upper limit of the flow-rate, is the highest flow-rate at which the heat meter shall function for short periods (< 1 hour/day; < 200 hour/year), without the maximum permissible errors being exceeded. QP, the permanent flow-rate, is the highest flow-rate at which the heat meter shall function continuously without the maximum permissible errors being exceeded. QI, the lower limit of the flow-rate, is the lowest flow-rate above which the heat meter shall function without the maximum permissible errors being exceeded.

Part code PDCSY-MW-CF-50-B PDCSY-MW-CF-65-B PDCSY-MW-CF-80-B PDCSY-MW-CF-80-C PDCSY-MW-CF-100-B PDCSY-MW-CF-100-C PDCSY-MW-CF-125-C PDCSY-MW-CF-150-C PDCSY-MW-CF-200-C

Size 50 mm 65 mm 80 mm 80 mm 100 mm 100 mm 125 mm 150 mm 200 mm

Litres/ pulse 100 100 100 1000 100 1000 1000 1000 1000

Qi (m3/h) 0.35 0.45 0.8 0.8 1.5 1.5 3 3.5 6.5

Qp (m3/h) 15 25 40 40 60 60 100 150 250

Qs (m3/h) 90 120 150 150 250 250 300 350 650

Cold Water Meters (Flanged connections)

Datasheet PDCSY-MW-F.pdf

PDCSY-MW-H

Hot Water Meters with pulsed output (non-continuous flow)

SCREWED HOT WATER METERS Inbuilt water strainer Complete with couplings Epoxy resin coated brass to DIN 50 930 part 6 Dry dial SPECIFICATION Max. fluid temperature Max. working pressure Installation position Part code PDCSY-MW-HS-15-A PDCSY-MW-HS-15-B PDCSY-MW-HS-20-A PDCSY-MW-HS-20-B PDCSY-MW-HS-25-A PDCSY-MW-HS-25-B PDCSY-MW-HS-32-A PDCSY-MW-HS-32-B PDCSY-MW-HS-40-B 90C (safety margin 120C) 16 bar Horizontal, dial upwards Size 15 mm () 15 mm () 20 mm () 20 mm () 25 mm (1) 25 mm (1) 32 mm (1) 32 mm (1) 40 mm (1) Litres/ pulse 10 100 10 100 10 100 10 100 100 QI (l/h) 30 30 50 50 75 75 120 120 200 QP (m3/h) 1.5 1.5 2.5 2.5 3.5 3.5 6 6 10 QS (m3/h) 3 3 5 5 7 7 12 12 20

PDCSY-MW-C

Cold Water Meters with pulsed output (non-continuous flow)

SCREWED COLD WATER METERS Inbuilt water strainer Complete with couplings Epoxy resin coated brass to DIN 50 930 part 6 Dry dial 30C (safety margin 50C) 16 bar Horizontal, dial upwards Size 15 mm () 15 mm () 20 mm () 20 mm () 25 mm (1) 25 mm (1) 32 mm (1) 32 mm (1) 40 mm (1) 50 mm (2) Litres/ pulse 10 100 10 100 10 100 10 100 100 100 QI (l/h) 30 30 50 50 70 70 120 120 200 450 QP (m3/h) 1.5 1.5 2.5 2.5 3.5 3.5 6 6 10 15 QS (m3/h) 3 3 5 5 7 7 12 12 20 30 FLANGED HOT WATER METERS Cast Iron body SPECIFICATION Max. fluid temperature 120C) Max. working pressure Flanges Installation position dial upwards

SPECIFICATION Max. fluid temperature Max. working pressure Installation position Part code PDCSY-MW-CS-15-A PDCSY-MW-CS-15-B PDCSY-MW-CS-20-A PDCSY-MW-CS-20-B PDCSY-MW-CS-25-A PDCSY-MW-CS-25-B PDCSY-MW-CS-32-A PDCSY-MW-CS-32-B PDCSY-MW-CS-40-B PDCSY-MW-CS-50-B

Datasheet PDCSY-MW-S.pdf

90C (safety margin 16 bar DIN 2501 PN16 Horizontal / vertical,

Datasheet PDCSY-MW-S.pdf Part code PDCSY-MW-HF-50-B PDCSY-MW-HF-65-B FLANGED COLD WATER METERS Cast Iron body SPECIFICATION Max. fluid temperature Max. working pressure Flanges Installation position 30C (safety margin 50C) 16 bar DIN 2501 PN16 Horizontal / vertical, dial upwards PDCSY-MW-HF-80-B PDCSY-MW-HF-80-C PDCSY-MW-HF-100-B PDCSY-MW-HF-100-C PDCSY-MW-HF-125-C PDCSY-MW-HF-150-C PDCSY-MW-HF-200-C Size 50 mm 65 mm 80 mm 80 mm 100 mm 100 mm 125 mm 150 mm 200 mm Litres/ pulse 100 100 100 1000 100 1000 1000 1000 1000 QI (m3/h) 0.35 0.45 0.8 0.8 1.5 1.5 3 3.5 6.5 QP (m3/h) 15 25 40 40 60 60 100 150 250 QS (m3/h) 90 120 150 150 250 250 300 350 650

Hot Water Meters (Flanged connections)

Datasheet PDCSY-MW-F.pdf

Tel: +33 (0) 4 78 45 01 23 Fax: +33 (0) 4 78 45 22 33 web: www.distech-controls.eu

17

Peripheral Programme
Flanged Flow Sensors PDCSY-MW-F flow sensors (DN50 to 200) can be installed horizontally or vertically. They are characterised by extremely low starting flows with high measuring accuracy and excellent measuring stability even in the most extreme of situations. This applies for the upper, as well as the lower measuring ranges.

PDCSY-MW

Flow Sensors with pulsed output

Meters for measuring the volume flow in heating and cooling systems. The MW range of flow sensors are meters especially designed for the special conditions in heating and cooling circuits. The pulse transmission takes place via the tried and tested reed-contact and is thus, compatible with the PDCSY-MW-MD. The special construction and the material design guarantee long-term measuring stability and high reliability. All of the flow sensors are designed for temperatures up to 120C with safety up to 130C. FEATURES Reinforced bearings High measuring stability Wide load range Reliable in operation up to 130C GENERAL SPECIFICATION Temperature range 10 to 120C (safety margin 130C) Max. operating pressure PN16 Connections PDCSY-MW-SJ & MJ types Screwed PDCSY-MW-F types Flanged Materials Screwed Brass Flanged Cast iron Weight 47 kg max.

Part code PDCSY-MW-F-50 PDCSY-MW-F-65 PDCSY-MW-F-80 PDCSY-MW-F-100 PDCSY-MW-F-125 PDCSY-MW-F-150 PDCSY-MW-F-200

Size 50mm (2) 65mm (2) 80mm (3) 100mm (4) 125mm (5) 150mm (6) 200mm (8)

QI (m3/h) 0.6 1 3.2 2 3 8 10

QP (m3/h) QS (m3/h) 15 25 40 60 100 150 250 60 60 90 180 250 300 500

Datasheet PDCSY-MW-FS.pdf

Single-jet Flow Sensors PDCSY-MW-SJ flow sensors (DN15 & 20) are very compact devices used for flows of up to Qn 2.5. They can be installed horizontally or vertically. Part code PDCSY-MW-SJ-15A PDCSY-MW-SJ-15B PDCSY-MW-SJ-20 Size 15 mm () 15 mm () 20 mm () QI (l/h) 12 30 50 QP (m3/h) 0.6 1.5 2.5 QS (m3/h) 1.2 3 5

Datasheet PDCSY-MW-SJ.pdf Multi-jet Flow Sensors PDCSY-MW-MJ flow sensors (DN20 to 40) have proven themselves for use with heavier flows. They are available for horizontal installation positions. The PDCSY-MW-MJR (riser pipe) and PDCSYMW-MJD (down pipe) meters have the advantage for vertical piping. Due to the low bearing load, this results in improvements in the long-term stability of measuring results. Part code PDCSY-MW-MJ-20A PDCSY-MW-MJ-20B PDCSY-MW-MJ-25A PDCSY-MW-MJ-25B PDCSY-MW-MJ-32 PDCSY-MW-MJ-40 PDCSY-MW-MJR-20 PDCSY-MW-MJR-25A PDCSY-MW-MJR-25B PDCSY-MW-MJR-32 PDCSY-MW-MRJ-40 PDCSY-MW-MJD-20 PDCSY-MW-MJD-25A PDCSY-MW-MJD-25B PDCSY-MW-MJD-32 PDCSY-MW-MJD-40 Size 20 mm () 20 mm () 25 mm (1) 25 mm (1) 32 mm (1) 40 mm (1) 20 mm () 25 mm (1) 25 mm (1) 32 mm (1) 40 mm (1) 20 mm () 25 mm (1) 25 mm (1) 32 mm (1) 40 mm (1) QI (l/h) 30 50 65 90 90 160 30 65 90 90 160 30 65 90 90 160 QP (m3/h) 1.5 2.5 3.5 6 6 10 1.5 3.5 6 6 10 1.5 3.5 6 6 10 QS (m3/h) 3 5 7 12 12 20 3 7 12 12 30 3 7 12 12 30

Horizontal Types

Vertical Riser Pipe Types

Vertical Down Pipe Types

Datasheet PDCSY-MW-MJx.pdf

18

Innovative Solutions for Greener Buildings

PDCSY-MW-MD

Heat Meter Integrators

PDCSY-MW-CHM Compact Heat Meters


Heat energy is calculated by using a matched pair of high accuracy sensors to measure the difference between the forward and flow temperatures. The amount of water flowing through the circuit is measured by the water meter, and the microprocessor-controlled calculator then calculates the consumed heat energy from the temperature and flow data. The large, easy-to-read display shows the energy used. Additional measurement and instrument data can be easily displayed by scanning the display loops. The integrated non-volatile E2PROM automatically stores the meter data once a day. It is possible to view the last 18 monthly values from the display. FEATURES Compact design Simple operation Measures heating or cooling Pulsed output or M-Bus options SPECIFICATION Water Meter Temperature range Nominal pressure Installation Cable length to heat meter Nominal diameter (DN) Nominal flow (QP) External thread Temperature Sensors Sensor element Sensor lead length Diameter Installation Flow Return Heat Meter Temperature range Display type Energy display Data storage Power supply Battery life Output pulse Conformity Measurement accuracy Ambient temperature Protection Weight

The PDCSY-MW-MD range of Heat Meter Integrators uses the latest innovative technology to calculate heat usage from heating and cooling systems. They are for use with mechanical flow parts. With its dynamic measuring cycle even the smallest energy consumptions are reliably collected. The large multifunction display permanently shows the heat consumption total, and by using the button it is possible to scroll through the display to show all data. FEATURES Simply operation Integral wall and DIN-rail mounting bracket Pulse or M-Bus output options Measures heating or cooling and heat/cooling SPECIFICATION Temp. range Temp. diff Supply Battery life Display Output pulse Frequency Pulse duration M-Bus Baud rate Sensor type Pocket thread Conformity Ambient range Dimension Protection Weight 1 to 150C 3 to 120 K 3.6 V Lithium battery 6 years (optional 11 year available upon request) Multifunction 8-digit + characters LCD 30 VDC max. @ 20 mA 1 Hz 400 m/s <TP < 600 m/s 2400 PT500 Matched pair 1/2 BSP EN1434, MID Annex, MI/EI @ Annex MI-004 Temperature 5 to 55C RH 95% non-condensing 106 x 54 x 120 mm (H x L x W) IP54 500 g

10 to 90C 16 bar Return 50 cm 15 mm 20 mm 15 mm 20 mm 15 mm 20 mm

0.6 or 1.5 m3/h 2.5 m3/h G3/4 G1

Part code PDCSY-MW-MD -P -M

Description Heat Meter Integrator (build unit with following options) Output Module (add type to above code) Pulsed output M-Bus (Requires an M-Bus Master) Pockets & PT500 Temp. Sensor (add type to above code)

PT500 1.5 m 5 mm 3/4 or 1 ball valve with integral pocket Integrated flow sensor 1 to 130C 8 digit LCD MWh Non-volatile memory, once daily 3 V Lithium battery > 6 years Max. operating voltage 30 VDC, 20mA max Pulse width 400-600 m/s MID (Annex B + Annex D) Class 3 (MID Annex MI-004) 5 to 55C IP54 1.02 kg

-A -B -C -D -E

45 mm pocket sensor pair 1.5 m cable 105 mm pocket sensor pair 3 m cable 105 mm pocket sensor pair 10 m cable 140 mm pocket sensor pair 3 m cable 140 mm pocket sensor pair 10 m cable Datasheet PDCSY-MW-MD.pdf

Typical order code: PDCSY-MW-MD-P-B Heat Meter Integrator with pulsed output, 50 mm pocket sensor pair with 3 m cable. Replacement Items Part code PDCSY-MW-PKT-1 PDCSY-MW-PKT-2 PDCSY-MW-PKT-3 Description 45 mm stainless steel pockets (pair) 105 mm stainless steel pockets (pair) 140 mm stainless steel pockets (pair)

The default location of the flow sensor is in the return. If the meter is to be fitted in the flow please advice at time of order. Part code PDCSY-MW-CHM-1 PDCSY-MW-CHM-2 PDCSY-MW-CHM-3 -A -B PDCSY-MW-BV-1 PDCSY-MW-BV-2 Description Compact Heat Meter - 0.6 m3/h nominal flow Compact Heat Meter - 1.5 m3/h nominal flow Compact Heat Meter - 2.5 m3/h nominal flow Output Options (add type to above code) Pulsed output M-Bus output (Requires an M-Bus Master) Replacement Items 3/4 ball valve supplied with sensor pocket MW-CHM 1 ball valve supplied with sensor pocket MW-CHM Datasheet PDCSY-MW-CHM.pdf

Tel: +33 (0) 4 78 45 01 23 Fax: +33 (0) 4 78 45 22 33 web: www.distech-controls.eu

19

Peripheral Programme

PDCSY-MW-U

Ultrasonic Flow Sensors

PDCSY-MW-M-BUS M-Bus Network


The PDCSY-MW-MD & PDCSY-MW-U range of Heat Meter Integrators, when ordered with the optional M-Bus output module and an M-Bus master, will allow up to 250 devices to be connected together on a network. Distech M-Bus masters allow either 32 or 250 meters to be read per network The M-Bus master module receives data from the meters, and using an EC-BOSAX, it is possible to read the meters and analyse the data. M-Bus was developed specifically for meter reading applications. Benefits include: Only 2-core cable required (multi-strand is preferred) Polarity independent connections Up to 250 devices per M-Bus segment Topologies supported are; Star - Each device is linked to a central master with an individual transmission line. The devices can transmit to the central master either sequentially or simultaneously. Disadvantage: Increased requirement for cabling.

Ultrasonic Heat Sensors have no moving parts in the volume flow which makes them almost wear free and noiseless. They measure the flow by using the transit time principle, one ultrasonic signal is launched in the flow direction and one against the flow direction. The flow rate is concluded by the delay time measured and the information is then transmitted to the calculator by the way of electronic pulses. The calculator uses the latest innovative technology to calculate heat usage from heating systems. With its dynamic measuring cycle even the smallest energy consumptions are reliably collected. The large multifunction display permanently shows the heat consumption total, and by using the button it is possible to scroll through the display to show all data. FEATURES Simple operation Long life ultrasonic flow meter Flow meter can be mounted in any position Integral wall and DIN-rail mounting bracket for calculator Pulsed or M-Bus output options SPECIFICATION Nominal flow rate Max. static pressure Body materials Temperature range Maximum temp Temperature diff Supply Battery life Display Output pulse Frequency Pulse duration M-Bus baud rate Flow sensor cable Sensor type Sensor lead lengths Sensor pockets Pocket thread Conformity Measurement & Accuracy Ambient range Protection Weight Part code PDCSY-MW-U -P -M -4 -5 -6 -7 -9 -E -F -G -H -J -4 -5 qp 0.6 to qp 60 m3/h Screwed 16 bar Flanged 25 bar Brass Heating 10 to 130C Cooling 10 to 50C 50C for 2000 h 3 to 120 K 3.6 V Lithium battery 6 years (optional 11 year available upon request) Multifunction 8-digit + characters LCD 30 VDC max. @ 20 mA 1 Hz 400 m/s < TP < 600m/s 2400 1.5 m to electronics, 2 m to calculator PT500 Matched pair 1.5 m (screwed types), 3 m (flanged types) 45 mm (screwed types), 105 mm (flanged types) 1/2 BSP MID Annex B + Annex D Class 2 (MID Annex MI-004) Temp. 5 to 55C, RH 95% non-condensing IP54 22.5 kg max.

M-Bus Master

Bus - The devices are connected together with a common transmission line, with the result that at any given time only one device can transmit data. Advantages: Very cost-effective No disruption if one of the devices fails

M-Bus Master

A combination of star and bus NB Ring topology is NOT supported.

Note: Distech recommends BUS topology only. M-Bus segments typically consist of: M-Bus slave devices (for example, heat meters) An M-Bus master/level convertor (A master unit - the EC-BOSAX - polls the slaves for data, the level convertor changes M-Bus data levels to RS232 for connection to a PC) M-Bus repeaters (if required) Maximum cable length per segment = 1000 m Maximum number of M-Bus slaves per segment = 250 M-Bus baud rate = 2400 Cable resistance < 73 / km Cable capacitance < 300 pF / 100 m * Single user PC licence. Other packages available on request. Part code PDCSY-MW-MASTER-32 Description M-Bus Master, 32 metering points Datasheet PDCSY-MW-M-BUS.pdf

Description Ultrasonic Flow Sensor Output Module (add type to above code) Pulsed output M-Bus (Requires an M-Bus Master) Flow Sensor (add type to above code) QP 0.6 m3/h, G3/4, (R1/2) screwed QP 1.5 m3/h, G3/4, (R1/2) screwed QP 2.5 m3/h, G1, (R3/4) screwed QP 3.5 m3/h, G11/4, (R1) screwed QP 10 m3/h, G2, (R11/2) screwed QP 10 m3/h, DN40 flanged QP 15 m3/h, DN50 flanged QP 25m3/h, DN65 flanged QP 40 m3/hh, DN80 flanged QP 60 m3/h, DN100 flanged System Type (add type to above code) Heating system Cooling system Datasheet PDCSY-MW-U.pdf

PDCSY-MW-MASTER-250 M-Bus Master, 250 metering points

Typical order code: PDCSY-MW-U-M-E-4 Heat Meter Integrator with M-Bus output, QP 10 m3/h flow meter (DN40 flanged) and for heating system.

20

Innovative Solutions for Greener Buildings

PDCSY-PA-930

Air DP Switches

PDCSY-PA-500

Multi-range Air DP Sensor

These are highly sensitive Air Differential Pressure Switches, suitable for providing an indication of fan status and dirty filter conditions. The switching setpoint is adjusted by means of a knob mounted under the main cover. Units are supplied complete with a duct fixing kit. FEATURES Duct fixing kit included IP54 or IP65 housing option

The PDCSY-PA-500 differential pressure transmitter is ideal for measuring filter conditions, as well as many other applications in ventilation/ air conditioning systems in buildings, laboratorys and clean rooms (air and non-corrosive gases). Featuring field-selectable output types and 4 pressure ranges, which are easily defined by user selection switches inside the rugged IP65 housing. Optional backplate (PDCSY-PA-ADPT) FEATURES User selectable measurement range and output type Duct fixing kit included Pre-wired for quick & easy installation IP65 housing SPECIFICATION Power supply: Current output 24Vdc 10% (3-wire) Voltage output 24Vac/dc 10% Power consumption: 1VA Measurement ranges: Selectable DP Resolution: 0 to 500Pa (2w/c) 0.2% fs Others 0.1% fs Pressure non-linearity: 0 to 500Pa (2w/c) 0-20% fs = 2%, 20-100% = 5% Others <1.5% fs Overall accuracy: 3% fs (0 to 70C / 32 to 158C) Long term stability: 0 to 500Pa (2w/c) Max 5% fs Others Max 1.5% fs Burst pressure: >5bar (72.5psi) Pressure connections: Push fit for 6.2mm i/d tube Electrical connections: 1m (3.2ft) flying lead Housing: Material Flame retardant ABS Dimensions 55mm (2.17) x 90mm (3.54) dia. Protection: IP65 Ambient range: Temperature 0 to 40C (32 to 104F) RH 0 to 85% RH, non-condensing Weight: 220g (0.49lb)

SPECIFICATION Operating ranges: Max. operating pressure: Pressure connections: Electrical rating: Connections: Housing material: Dimensions: 3.90) Protection: Ambient range: Weight:

Type: Adjustment range: PDCSY-PA-930-80 20 to 200Pa (0.08 to 0.80w/c) PDCSY-PA-930-83 50 to 500Pa (0.20 to 2w/c) PDCSY-PA-930-85 200 to 1000Pa (0.8 to 4w/c) 5000Pa (20w/c) 6mm i/d push-on tubing 1.5A (0.4)/250Vac AgCdO contacts Spade terminals and screw terminal adaptors for cable up to 1.5mm2 max. Plastic moulding IP54 85mm (3.35) dia. x 59mm (2.32) IP65 130 x 130 x 99mm (5.12 x 5.12 x IP54 or IP65 Temperature 20 to +85oC (4 to +185F) RH 0 to 95% RH, non-condensing 250g (0.55 lb)

Note: A duct fixing kit (DFK) is supplied with the switch, consisting of 2m (6.56 ft) 5mm (0.20) i/d plastic tubing, 2 x pitot tubes and 4 x fixing screws.

Part code PDCSY-PA-930-80 PDCSY-PA-930-83 PDCSY-PA-930-85 PDCSY-PA-930-80-IP65 PDCSY-PA-930-83-IP65 PDCSY-PA-930-85-IP65 PDCSY-PA-ADPT PDCSY-PA-930-B PDCSY-DFK PDCSY-TEE PDCSY-PA-TUBE-8MM

Description IP54 Switch Housing 20 to 200Pa (0.08 to 0.80w/c) 50 to 500Pa (0.20 to 2w/c)

Part code Pressostat PDCSY-DFK PDCSY-TEE PDCSY-PA-TUBE-8MM PDCSY-PA-500

Description 0 to 50, 100, 300 & 500Pa Multi Range Selectable (0 to 0.2, 0 to 0.4, 0 to 1.2 & 0 to 2w/c) 0-10Vdc or 4-20mA (3-wire) Selectable Output Accessories Duct fixing kit Tee piece air pressure (pack of 10) PVC tube 8mm o/d x 1.5mm wall, 30m reel Data sheet PDCSY-PA-500.pdf

200 to 1000Pa (0.8 to 4w/c) IP65 Switch Housing (including switch) 20 to 200Pa (0.08 to 0.80w/c) 50 to 500Pa (0.20 to 2w/c) 200 to 1000Pa (0.8 to 4w/c) Accessories Optional backplate Right angle mounting bracket Duct fixing kit Tee piece air pressure (pack of 10) PVC tube 8mm o/d x 1.5mm wall, 30m reel Data sheet PDCSY-PA-930.pdf

Note: A duct fixing kit (DFK) is supplied with the sensor, consisting of 2m (6.56 ft) 5mm (0.20) i/d plastic tubing, 2 x pitot tubes and 4 x fixing screws.

The IP65 option DP switch is connected (in the factory) to custom made nipples mounted in the housing. This eliminates awkward piping on-site and makes the product much easier to fit, and reduces installation time.

Tel: +33 (0) 4 78 45 01 23 Fax: +33 (0) 4 78 45 22 33 web: www.distech-controls.eu

21

Peripheral Programme

PDCSY-PA-267

Air DP Sensors

PDCSY-PA-699

Multi-range Air DP Sensors

These sensors are designed for differential pressure measurements of air and other neutral gases. The unit is especially suited for measurement and control in HVAC applications. The measurement cell uses an advanced design capacitive element to ensure excellent linearity and stability. FEATURES Two accuracy levels to suit different applications Available in ranges as low as 0-25 Pa Integral LCD option IP65 housing with 20 mm cable entry and gland Duct fixing kit included SPECIFICATION Accuracies Standard High Overall 1.00% fsd 0.40% fsd Linearity 0.98% fsd 0.33% fsd Hysteresis 0.20% fsd 0.20% fsd Repeatability 0.10% fsd 0.10% fsd Total 1.28% fsd 0.63% fsd Thermal effect 0.06% per C Over pressure 10 psi (68 kPa) Pressure connections Push fit for 6 mm i/d tube Output Current 4-20 mA, load: 100 to 800 Voltage 0-10 VDC (o/p impedance < 100 k) Power supply Current Min. 9 VDC + (0.02 x load resistance) Max. 30 VDC + (0.004 x load resistance) Voltage 9-30 VAC or 12-40 VDC Diaphragm Stainless steel 304SS Housing Glass-filled polycarbonate to UL94V-0 Protection IP65 Operating temp 18 to +65C Dimensions 158 x 80 x 60 mm max. Weight 340 g Note: A duct fixing kit (DFK) is supplied with the sensor, consisting of 2 m of 6 mm i/d plastic tubing, 2 x pitot tubes and 4 x fixing screws. Part code PDCSY-PA-267-25 PDCSY-PA-267-50 PDCSY-PA-267-100 PDCSY-PA-267-300 PDCSY-PA-267-500 PDCSY-PA-267-1000 PDCSY-PA-267-1600 PDCSY-PA-267-2500 PDCSY-PA-267-3000 -V -B -AH -LCD PDCSY-DFK PDCSY-TEE PDCSY-PA-TUBE-8MM PDCSY-PA-267-CAL * Description Air DP Sensor - 0 to 25 Pa, 4-20 mA Air DP Sensor - 0 to 50 Pa, 4-20 mA Air DP Sensor - 0 to 100 Pa, 4-20 mA Air DP Sensor - 0 to 300 Pa, 4-20 mA Air DP Sensor - 0 to 500 Pa, 4-20 mA Air DP Sensor - 0 to 1000 Pa, 4-20 mA Air DP Sensor - 0 to 1600 Pa, 4-20 mA Air DP Sensor - 0 to 2500 Pa, 4-20 mA Air DP Sensor - 0 to 3000 Pa, 4-20 mA Suffixes (add to above part code) 0-10V voltage output Bi-directional High accuracy Integral LCD display Accessories Duct fixing kit Tee piece air pressure (pack of 10) PVC tube 8mm (0.31) o/d x 1.5mm (0.06) wall, 30m (98.5 ft) reel Calibration certificate Data sheet PDCSY-PA-267.pdf Note: 1. A duct fixing kit (PDCSY-DFK) is supplied with the sensor, consisting of 2 m of 6 mm i/d plastic tubing, 2 x pitot tubes and 4 x fixing screws. 2. * These options must be specified at time of sensor order. They are built to order and not available ex-stock.

This range of field selectable Multi-range Differential Pressure Transmitters, incorporate a proven ceramic fulcrum lever technology for pressure measurement. The PDCSY-PA-699 has up to three field selectable ranges in one unit, providing versatility for a multitude of applications. FEATURES Adjustable measurement range IP65 housing Duct fixing kit included Compact construction SPECIFICATION Accuracy, total of linearity, hysteresis & repeatability (% fs) PDCSY-PA-699-01 to 04 Others Thermal effect (typical % fs/10K) TC zero point PDCSY-PA-699-01 0.02 PDCSY-PA-699-02 0.02 PDCSY-PA-699-03 0.02 PDCSY-PA-699-04 0.01 Others 0.01 Rupture pressure 2 x overload at ambient temp. Power supply Current output 8 to 33 VDC Voltage 13.5 to 33 VDC or 24 VAC 15% Pressure connections 6 mm i/d push-on tube Diaphragm Silicone Housing Polycarbonate PC Temperature Medium & ambient 0 to 70C Storage 10 to +70C Protection IP65 Dimensions 92 x 75 x 47.9 mm Weight 186 g

1.0 max. 0.6 TC sensitivity 0.03 0.03 0.02 0.01 0.01

Part code PDCSY-PA-699-01 PDCSY-PA-699-02 PDCSY-PA-699-03 PDCSY-PA-699-04 PDCSY-PA-699-05 PDCSY-PA-699-06 PDCSY-PA-699-07 PDCSY-PA-699-08 -V -LCD PDCSY-DFK PDCSY- TEE PDCSY-PA-TUBE8MM PDCSY-PA-BRK PDCSY-PA-699-CAL *

Description Bi-directional Multi-Range Air DP Sensor 0 to 30, 50 & 100 Pa, 4-20 mA Multi-Range Air DP Sensor 0 to 30, 50 & 100 Pa, 4-20 mA Multi-Range Air DP Sensor 0 to 50, 100 & 300 Pa Multi-Range Air DP Sensor 0 to 100, 300 & 500 Pa Multi-Range Air DP Sensor 0 to 300, 500 & 1000 Pa Multi-Range Air DP Sensor 0 to 500, 1000 & 1600 Pa Multi-Range Air DP Sensor 0 to 1000, 1600, 2500 Pa Multi-Range Air DP Sensor 0 to 1600, 2500 & 5000 Pa Suffixes (add to above part code) 0-10 V voltage output Integral LCD option Accessories Duct fixing kit Tee piece air pressure (pack of 10) PVC tube 8 mm o/d x 1.5 mm wall, 30 m reel DIN-rail bracket Calibration certificate

Data sheets PDCSY-PA-699.pdf Note: 1. A duct fixing kit (PDCSY-DFK) is supplied with the sensor, consisting of 2 m of 6 mm i/d plastic tubing, 2 x pitot tubes and 4 x fixing screws. 2. * This option must be specified at time of sensor order. It is built to order and not available ex-stock.

22

Innovative Solutions for Greener Buildings

PDCSY-PL-528

Static Pressure Transmitter

PDCSY-PL-625

Static Pressure Switches

The new range of static pressure transmitters are suitable for use with a large range of liquids and gases compatible with the FPM (Viton) seal. The pressure transmitter is based on proven ceramic technology for exceptional performance speed and reliability. FEATURES Compact rugged construction Negligible temperature influence on accuracy IP65 protection Electrical terminals and gland to DIN EN175 301-803-A Supply short circuit & polarity reversal protection SPECIFICATION Supply voltage: PDCSY-PL-528-x 7Vdc to 33Vdc PDCSY-PL-528-x-V 12Vdc to 33Vdc or 24Vac 15% Output: PDCSY-PL-528-x 4-20mA PDCSY-PL-528-x-V 0-10Vdc Response time: <2ms, 1ms typical Overload/rupture pressure: 0 to 4 bar 3 x measuring range full scale 6 to 40 bar 2.5 x measuring range full scale Materials: Pressure connection S/S 1.4305 / AISI 303 Sensor Ceramic Al2O3 (96%) Sealing material FPM (Viton) Pressure connection: BSP male manometer combi Temperature: Media -15 to +125C Ambient -30 to +85C Protection: IP65 Dimensions: 105 x 65mm Weight: 105g Part code PDCSY-PL-528-1 PDCSY-PL-528-1.6 PDCSY-PL-528-2.5 PDCSY-PL-528-4 PDCSY-PL-528-6 PDCSY-PL-528-10 PDCSY-PL-528-16 PDCSY-PL-528-25 PDCSY-PL-528-40 PDCSY-PL-528-1-V PDCSY-PL-528-1.6-V PDCSY-PL-528-2.5-V PDCSY-PL-528-4-V PDCSY-PL-528-6-V PDCSY-PL-528-10-V PDCSY-PL-528-16-V PDCSY-PL-528-25-V PDCSY-PL-528-40-V PDCSY-PL-HS PDCSY-PL-528-CAL * Description 4-20mA Output (2-wire loop powered) 0 to 1 bar Static Pressure Sensor 0 to 1.6 bar 0 to 2.5 bar 0 to 4 bar 0 to 6 bar 0 to 10 bar 0 to 16 bar 0 to 25 bar 0 to 40 bar

Features optimised polymer diaphragm technology to give long term stability and excellent repeatability of switching points and housed within a rugged industrial case. FEATURES Suitable for liquids and gases High vibration resilience Adjustable switching differential Spade connectors and gland supplied SPECIFICATION Max. test pressure 10 bar Max. operating pressure 11/2 x range Lowest turn-on pressure 120 mbar Pressure connection 1/4 BSP male Media Water, air and steam (with pigtail siphon) Electrical rating 6 (3) A @ 250 VAC Contact system Changeover contact Operating range 10 to +80C Protection IP54 Dimensions 98 x 65 mm Weight 260 g Part code PDCSY-PL-625-2.2 PDCSY-PL-625-6 Description Static Pressure Switch - 120 to 2200 mbar (0.12 to 2.2 bar) Static Pressure Switch - 1000 to 6000 mbar (1 to 6 bar) Data sheet PDCSY-PL-625.pdf

PDCSY-PL-630

Differential Pressure Switches

Ideal for flow monitoring and proving applications in heating, ventilating and air-conditioning systems. FEATURES Over-pressure safety capability to 10 bar / 20 bar Mechanically isolated switching chamber for safety and reliability Medium temperatures to 80C Rugged construction Adjustable setting and differential SPECIFICATION Max. operating pressure and overload on one side (P1>P2) With range 200 mbar = 10 bar With range 150 to 1000 mbar = 20 bar Lowest turn-on pressure 15 mbar Pressure connection 1/8 BSP female Media Water, air and steam (with pigtail siphon) Electrical rating 1 (0.5) A @ 250 VAC Contact system Changeover contact Operating range 10 to +80C Protection IP65 Dimensions 115 x 65 mm Weight 1.08 kg Part code PDCSY-PL-630-0.06 PDCSY-PL-630-0.2 PDCSY-PL-630-1 PDCSY-PL-630-3 PDCSY-PL-630-5.5 Description Differential Pressure Switch - 15 to 60 mbar Differential Pressure Switch - 40 to 200 mbar Differential Pressure Switch - 0.15 to 1 bar Differential Pressure Switch - 1 to 3 bar Differential Pressure Switch - 2 to 5.5 bar Data sheet PDCSY-PL-630.pdf Note: A mounting bracket is supplied with the switch.

0-10Vdc Output

0 to 1 bar Static Pressure Sensor


0 to 1.6 bar

0 to 2.5 bar
0 to 4 bar

0 to 6 bar
0 to 10 bar 0 to 16 bar 0 to 25 bar 0 to 40 bar Pressure Transmitter Heat Sink Calibration certificate Datasheet - PDCSY-PL-528.pdf

Accessories

Note: 1. Heat Sink PDCSY-PL-HS can be used where media has a higher temperature than the sensor allows. 2. * This option must be specified at the time of sensor order. It is built to order and not available ex-stock.

Tel: +33 (0) 4 78 45 01 23 Fax: +33 (0) 4 78 45 22 33 web: www.distech-controls.eu

23

Peripheral Programme

PDCSY-PL-652 Low Range Differential Pressure Sensors


A sensor for liquids and gases which uses the Hall Effect sensing technology. The high over pressure resilience and rugged mechanical construction make this product suitable for a wide range of HVAC applications. FEATURES Output signal in current or voltage High over pressure safety margin High linearity, accuracy and repeatability Rugged IP65 case construction Suitable for mildly aggressive liquids and gases SPECIFICATION Supply voltage: 20-30Vdc Max. operating pressure and overload on one side (P1>P2): 10 bar (145 psi) Pressure connection: 1/8 BSP female Media: Water, air and steam (with pigtail siphon) Operating range: 10 to +80C (14 to 176F) Protection: IP65 Dimensions: 110 x 65mm (4.33 x 2.56) Weight: 940g (2.07 lb) Part code PL-652-0.05 PL-652-0.05-V PL-652-CAL * Description 4-20mA Output (3-wire) 0 to 50 mbar (0 to 0.7 psi) Diff. Pressure Sensor 0-10Vdc Output 0 to 50 mbar (0 to 0.7 psi) Diff. Pressure Sensor Accessory Calibration certificate Data sheet PDCSY-PL-652.pdf

PDCSY-PL-692

Differential Pressure Sensors

For high accuracy and close control applications, the PDCSY-PL-692 features ceramic sensing technology for exceptional accuracy and reliability. The amplified sensing technologies allow high temperature stability and no creepage associated with mechanical systems. FEATURES Current and voltage output models Supplied with 6 mm o/d fittings Easy installation and wiring Electrical terminals and gland to DIN EN175 301-803-A High temperature stability SPECIFICATION Supply voltage Response time Pressure connection Media Temperature Protection Dimensions Weight 4-20 mA 11 to 33 VDC 0-10 VDC,18 to 33 VDC or 24 VAC 15% < 5 ms 6 mm compression Water, air and steam (with pigtail siphon) Ambient & media 15 to +80C IP65 130 x 40 mm 640 g

Part code PDCSY-PL-692-0.1 PDCSY-PL-692-0.2 PDCSY-PL-692-0.4 PDCSY-PL-692-1 PDCSY-PL-692-2.5 PDCSY-PL-692-4 PDCSY-PL-692-6 PDCSY-PL-692-10 PDCSY-PL-692-16 PDCSY-PL-692-0.1-V PDCSY-PL-692-0.2-V PDCSY-PL-692-0.4-V PDCSY-PL-692-1-V PDCSY-PL-692-2.5-V PDCSY-PL-692-4-V PDCSY-PL-692-6-V PDCSY-PL-692-10-V PDCSY-PL-692-16-V

Description 4-20 mA Output (2-wire loop powered) Differential Pressure Sensor - 0 to 100 mbar Differential Pressure Sensor - 0 to 200 mbar Differential Pressure Sensor - 0 to 400 mbar Differential Pressure Sensor - 0 to 1 bar Differential Pressure Sensor - 0 to 2.5 bar Differential Pressure Sensor - 0 to 4 bar Differential Pressure Sensor - 0 to 6 bar Differential Pressure Sensor - 0 to 10 bar Differential Pressure Sensor - 0 to 16 bar 0-10 VDC Output Differential Pressure Sensor - 0 to 100 mbar Differential Pressure Sensor - 0 to 200 mbar Differential Pressure Sensor - 0 to 400 mbar Differential Pressure Sensor - 0 to 1 bar Differential Pressure Sensor - 0 to 2.5 bar Differential Pressure Sensor - 0 to 4 bar Differential Pressure Sensor - 0 to 6 bar Differential Pressure Sensor - 0 to 10 bar Differential Pressure Sensor - 0 to 16 bar Accessory

Note: 1. A mounting bracket is supplied with the sensor. 2. * This option must be specified at the time of sensor order. It is built to order and not available ex-stock.

PDCSY-PL-691

Low Range Static Pressure Sensors

The speed and accuracy of the PDCSY-PL-691 range, made possible by the ceramic sensing technology, make them particularly suitable to level sensing and other applications where close control is required. FEATURES Current and voltage output models Easy installation and wiring Solid state sensing technology High over-pressure resilience SPECIFICATION Supply voltage Response time Overload Pressure connection Media Temperature Protection Dimensions Weight Part code PDCSY-PL-691-0.1 PDCSY-PL-691-0.2 PDCSY-PL-691-0.3 PDCSY-PL-691-0.6 PDCSY-PL-691-0.1-V PDCSY-PL-691-0.2-V PDCSY-PL-691-0.3-V PDCSY-PL-691-0.6-V PDCSY-PL-HS PDCSY-PL-691-CAL * 4-20 mA 11 to 33 VDC 0-10 VDC 18 to 33 VDC or 24 VAC 15% < 5 ms 2 x measuring range (rupture 3 x) 1/2 BSP male Water, air and steam (with PDCSY-PL-HS) Ambient & media 15 to +80C IP65 132 x 40 mm 260 g Description 4-20 mA Output (2-wire loop powered) 0 to 100 mbar (0 to 1.5 psi) Static Pressure Sensor 0 to 200 mbar (0 to 2.9 psi) Static Pressure Sensor 0 to 300 mbar (0 to 4.4 psi) Static Pressure Sensor 0 to 600 mbar (0 to 8.7 psi) Static Pressure Sensor 0-10Vdc Output 0 to 100 mbar (0 to 1.5 psi) Static Pressure Sensor 0 to 200 mbar (0 to 2.9 psi) Static Pressure Sensor 0 to 300 mbar (0 to 4.4 psi) Static Pressure Sensor 0 to 600 mbar (0 to 8.7 psi) Static Pressure Sensor Accessories Pressure Transmitter Heat Sink Calibration certificate

PDCSY-PL-692-CAL * Calibration certificate Data sheet PDCSY-PL-692.pdf Note: 1. A mounting bracket is supplied with the sensor. 2. * This option must be specified at the time of sensor order. It is built to order and not available ex-stock.

Data sheet PDCSY-PL-691.pdf, PDCSY-PL-HS.pdf Note: 1. Heat Sink PDCSY-PL-HS can be used where media has a higher temperature than the sensor allows. 2. * This option must be specified at the time of sensor order. It is built to order and not available ex-stock.

24

Innovative Solutions for Greener Buildings

PDCSY-PL-FD113 Liquid DP Switch


Liquid Differential Pressure Switch suitable for monitoring flow status across pumps, chillers, valves etc. The switch has an adjustable set point from 0.3 bar to 4.5 bar with a fixed differential of 0.2 bar. A dial on the front indicates the approximate setting of the switch. FEATURES SPDT switch Single unit covers a wide pressure range Simple to configure SPECIFICATION Range Switching differential Pipe connections Ambient temperature Liquid temperature Switch rating Protection Dimensions Weight 0.3 to 4.5 bar 0.2 bar 1/4 BSP female 0 to 50C 0 to 110C 5 (3) A @ 240 VAC IP30 128 x 175 x 48 mm 800 g

PDCSY-PM-EM21 Energy Analyser (DIN-rail or panel mounted)


The PDCSY-PM-EM21 is a compact Energy Meter that has a removable front LCD display that allows it to be either DIN-rail or panel mounted. The energy meter is designed for active and reactive energy metering. All operations, including programming and viewing up to seven display pages are performed using the two push buttons on the detachable display. It is possible to block the access to programming by means of a trimmer position on the rear of the display. Certified according to MID Directive, Annex B Type examination relevant to active electrical energy meters (see EU Directive 2004/22/EC, Annex MI-003). FEATURES Pulsed or Modbus output options Self powered 5 A CT secondary current Compact size Detachable display Multi-use housing for both DIN-rail and panel mounting applications APPLICATIONS 3-Phase, 4-wire balanced & unbalanced load 3-Phase, 3-wire balanced & unbalanced load 2-Phase, 3-wire 1-Phase, 2-wire CHARACTERISTICS Measurements SPECIFICATION Frequency Display Housing Mounting Output types RS 485 Refresh time Ambient Protection Dimensions Weight Part code PDCSY-PM-EM21-P PDCSY-PM-EM21-M -B+D System W, var, PF, Hz, Phase-sequence Single-phase VLL, VLN, A, PF, kWh, kvarh 45 to 65 Hz 2 lines Nylon PA66, self-extinguishing UL 94 V-0 DIN-rail or panel Pulse Open collector Modbus RS485 Address Programmable, 1 to 247 Baud-rate 9600 bit/s 1/s Humidity 0 to 90% (non-condensing) Temperature 25 to +55C IP50 (front) 72 x 72 x 65 mm 260 g Description Energy Analyser Pulsed Output Energy Analyser Modbus Output Option (add to part code above) Annex B+D Certification Data sheet PDCSY-PM-EM21.pdf

Part code PDCSY-PL-FD113

Description Liquid DP Switch - 0.2 to 4.0 bar Data sheet PDCSY-PL-FD113.pdf

Note: A mounting bracket is supplied with the switch.

PDCSY-PL-PSA

Liquid Pressure Switches

Adjustable Pressure Switches, suitable for the monitoring of flow failure and proving in pumps, chillers, valves etc. Units have an adjustable setpoint and differential. FEATURES Adjustable pressure range Narrow adjustable differential depending on model Range and differential pointer units in bar and psig High rated SPDT contacts Shatter resistant contacts Captive terminal and cover screws SPECIFICATION Range PDCSY-PL-PSA1 - 0.75 to 3 bar PDCSY-PL-PSA2 - 0.8 to 1.5 bar, PDCSY-PL-PSA3 - 0.5 to 7 bar Differential PDCSY-PL-PSA1 - 0.25 to 1.5 bar PDCSY-PL-PSA2 - 0.2 to 1 bar, PDCSY-PL-PSA3 - 0.5 to 5 bar Pressure connections 14 BSP male Ambient temperature 50 to +70C Liquid temperature 50 to +70C Switch rating 230 VAC @ 24 (10) A Protection IP44 Dimensions 42 x 85 x 75 mm max. Weight 346 g

Part code PDCSY-PL-PSA1 PDCSY-PL-PSA2 PDCSY-PL-PSA3

Description Liquid Pressure Switch - 0.75 to 3 bar, auto reset Liquid Pressure Switch - 0.8 to 1.5 bar Liquid Pressure Switch - 0.5 to 7 bar Data sheet PDCSY-PL-PSA.pdf

Tel: +33 (0) 4 78 45 01 23 Fax: +33 (0) 4 78 45 22 33 web: www.distech-controls.eu

25

Peripheral Programme

PDCSY-PM-EM24 Energy Analyser (DIN-rail)


The PDCSY-PM-EM24 DIN-rail mounted Energy Analyser is designed for active and reactive energy metering. When using the optional RS-485 Modbus output it is possible to connect up to three additional pulse inputs from other metering equipment enabling all consumption data to be read from just one meter. PDCSY-PM-EM24 features eight user-selectable applications are available to allow fast setup, with lockable programme selector, and joystick control of up to 31 LCD display pages. Certified according to MID Directive, Annex B Type examination relevant to active electrical energy meters (see EU Directive 2004/22/EC, Annex MI-003). FEATURES Wide angle variable readout Gas and water measurements and multi-tariff management in one unit Easy variable scrolling by means of the front joystick Pulsed or Modbus output options 5 A CT secondary current Two digital outputs (alarms or/and pulses) or RS485 communication port APPLICATIONS 3-Phase, 3-wire balanced & unbalanced load 3-Phase, 4-wire balanced & unbalanced load 2-Phase, 3-wire 1-Phase, 2-wire CHARACTERISTICS Measurements System Single-phase SPECIFICATION Frequency Display Housing Mounting Output types: RS 485 Sampling rate Display refresh time Ambient Protection Dimensions Weight Part code PDCSY-PM-EM24-P PDCSY-PM-EM24-M PDCSY-PM-PMK VLL, VLN, Admd max, var, VA, W, Wdmd, Wdmd max, VAdmd, VAdmd max, PF, Hz VLL, VLN, A, W, var, VA, PF, Admd, kWh, kvarh, hour counter

PDCSY-PM-CT-X

Current Transformers

The range of current transformers are available in moulded, split core and ring types. They all suitable for use with the PDCSY-PM-EM range of kWh meters. The split core Current transformers are partially useful for retrofits, upgrades and temporary installations, as they can be fitted without any disruption to the existing installation. FEATURES Ratings from 50 to 800A 5A secondary current SPECIFICATION Overload: Frequency: Insulation level: Connections: Conformity: Ambient range: Temperature Weight: Part code PDCSY-PM-CT-M100 PDCSY-PM-CT-M150 PDCSY-PM-CT-M200 PDCSY-PM-CT-M250 PDCSY-PM-CT-M300 PDCSY-PM-CT-M400 PDCSY-PM-CT-M500 PDCSY-PM-CT-M600 PDCSY-PM-CT-M800 PDCSY-PM-CT-100SC PDCSY-PM-CT-150SC PDCSY-PM-CT-200SC PDCSY-PM-CT-250SC PDCSY-PM-CT-300SC PDCSY-PM-CT-400SC PDCSY-PM-CT-500SC PDCSY-PM-CT-600SC PDCSY-PM-CT-800SC PDCSY-PM-CT-R50 PDCSY-PM-CT-R100 PDCSY-PM-CT-R150 PDCSY-PM-CT-R250 PDCSY-PM-CT-R300 PDCSY-PM-CT-R400 PDCSY-PM-CT-R500 PDCSY-PM-CT-R800 1.2 x rated current (continuous) 50/60Hz 3kV (50Hz) for 1 minute (not PM-CT-M) PDCSY-PM-CT-M Screw terminals PDCSY-PM-CT-xSC 1m tails (3.28 ft) PDCSY-PM-CT-R M6 lug terminals PDCSY-PM-CT-xSC IEC185, BS7626, BSEB 60044-1 PDCSY-PM-CT-R IEC44-1, IEC185, BS7626 Humidity up to 95% RH (non-condensing) 20 to +85C (PM-CT-M) (4 to +185F) 30 to +85C (others) (22 to +185F) 750g max. (1.65 lb) Description Moulded Types 100A, 2.5VA Current Transformer 150A, 2.5VA Current Transformer 200A, 5VA Current Transformer 250A, 5VA Current Transformer 300A, 5VA Current Transformer 400A, 5VA Current Transformer 500A, 10VA Current Transformer 600A, 10VA Current Transformer 800A, 10VA Current Transformer Split Core Types 100A, 1VA Current Transformer 150A, 1.5VA Current Transformer 200A, 2.5VA Current Transformer 250A, 2.5VA Current Transformer 300A, 2.5VA Current Transformer 400A, 5VA Current Transformer 500A, 5VA Current Transformer 600A, 5VA Current Transformer 800A, 5VA Current Transformer Ring Types 50A, 2.5VA Current Transformer 100A, 10VA Current Transformer 150A, 15VA Current Transformer 250A, 15VA Current Transformer 300A, 15VA Current Transformer 400A, 15VA Current Transformer 500A, 15VA Current Transformer 800A, 15VA Current Transformer

45 to 65 Hz 3 lines (1 x 8 digit., 2 x 4 digit.) Nylon PA66, self-extinguishing UL 94 V-0 DIN-rail Pulse Open collector Modbus RS485 Address Programmable, 1 to 247, Baud-rate Programmable, 4800, 9600 bit/s 1600 samples /s @ 50 Hz 1900 samples /s @ 60 Hz 750 m/s Humidity 0 to 90% (non-condensing) Temperature 25 to +55C IP50 (front) 90 x 71 x 65 mm 360 g Description Energy Analyser Pulsed Output Energy Analyser Modbus Output Accessory Panel door mounting kit Data sheet PDCSY-PM-EM24.pdf

Data sheet PDCSY-PM-CT-M.pdf, PDCSY-PM-xSC.pdf, PDCSY-PM-CT-R.pdf

26

Innovative Solutions for Greener Buildings

PDCSY-PM-CTR

Current Transducers

PDCSY-PM-CSX

Current Switches

This new series of Current Transducers provide accurate load trending information with a choice of 4-20mA, 0-10Vdc and 0-5Vdc output signals. They provide accurate, reliable and maintenance-free operation. Solid and split-core versions are available with current ratings up to 100A. current versions are supplied with pre-wired 400mm (15.75) tails and voltage versions have screw terminals. Both versions have a unique self-gripping feature which allows the switch to literally clip on to a cable without the need for a base mounting plate. APPLICATIONS Load trending Motor control FEATURES Power the sensor and receive the signal with only two wires Split core versions for fast retrofit installation with no need to remove conductor Dip-switch selectable ranges on 0-10Vdc version SPECIFICATION Supply: Current output Loop powered Voltage output Self powered Maximum sense voltage: 600Vac Accuracy: Current output 99% FS (25-100% span) Voltage output 96.8% FS Temperature range: 35 to +60C (31 to +140F) Humidity range: 0 to 95%, non-condensing Dimensions: Split core types 65 x 50 x 30mm (2.56 x 1.97 x 1.18) hole 13 x 13mm (0.51 x 0.51), self-gripping clamp Solid core types 53 x 37 x 24mm (20.9 x 1.46 x 0.94) hole 13mm (0.51) dia. Conformity: CEmarked Weight: 100g (0.22lb) Part code PDCSY-PM-CTR01 PDCSY-PM-CTR02 PDCSY-PM-CTR03 PDCSY-PM-CTR04 PDCSY-PM-CTR05 PDCSY-PM-CTR06 PDCSY-PM-CTR07 PDCSY-PM-CTR08 PDCSY-PM-CTR09 PDCSY-PM-CTR10 PDCSY-PM-CTR11 Description 4-20mA Output 0 to 20A, split core Current Transducer 0 to 50A, split core Current Transducer 0 to 100A, split core Current Transducer 0 to 20A, solid core Current Transducer 0 to 50A, solid core Current Transducer 0 to 100A, solid core Current Transducer 0-5Vdc Output 0 to 10A, solid core Current Transducer 0 to 20A, solid core Current Transducer 0 to 50A, solid core Current Transducer 0 to 100A, solid core Current Transducer 0-10Vdc Output 20/50/100A, split core Current Transducer Data sheets PDCSY-PM-CTR.pdf

A new range of Current Switches offer adjustable or fixed setpoints and provides accurate, reliable and maintenance-free operation. Output switching options include 30Vac/dc @ 1A or 240Vac @ 1A, with current ratings of up to 150A. Both versions have a unique self-gripping feature which allows the switch to literally clip on to a cable without the need for a base mounting plate. APPLICATIONS Detection of fan belt breakage Detection of motor failure Verifying lighting circuits Monitoring critical motors (compressors etc.) Process equipment status ADJUSTABLE SETPOINT TYPES Allow for easy detection of broken drive belts, drive belt slip or pump coupling shear. A typical HVAC motor that loses its load has a reduction of current draw of up to 50%. FEATURES Adjustable set-point More reliable and cost-effective than differential pressure switches 100% solid-state output, no moving parts to fail Output status LEDs for fast setup Self-powered FIXED SETPOINT TYPES Provide a cost-effective solution for monitoring the status of unit vents, exhaust fans, recirculation pumps and other fixed loads where belt loss is not a concern FEATURES More reliable for status than relays across auxiliary contacts Ideal for lighting status Monitor status of fans, pumps, motors and other electrical loads SPECIFICATION Supply: Self-powered from monitored line Insulation class: 600Vac Trip setpoint: PDCSY-PM-CSA01 - 0.75 to 150A PDCSY-PM-CSF01 - 0.35A or less PDCSY-PM-CSA02 - 0.5 to 150A PDCSY-PM-CSF02 - 0.25A or less PDCSY-PM-CSF03 - 0.5A or less Sensor power: Induced from monitored conductor Temperature range: 35 to +60C (31 to +140F) Humidity range: 0 to 95%, non-condensing Dimensions: Split core types 65 x 50 x 30mm (2.56 x 1.97 x 1.18 hole 13 x 13mm (0.51 x 0.51), self-gripping clamp Solid core types 53 x 37 x 24mm (2.09 x 1.46 x 0.94) hole 13mm (0.51) dia Conformity: CEmarked Weight: 100g (0.22lb) max.

Part code PDCSY-PM-CSA01 PDCSY-PM-CSA02 PDCSY-PM-CSF01 PDCSY-PM-CSF02 PDCSY-PM-CSF03

Description Adjustable Setpoint Types 0.75 to 150A - 30Vac/dc, split core 0.5 to 150A - 30Vac/dc, solid core Fixed Setpoint Types 0.35 to 150A - 30Vac/dc, split core 0.25 to 150A - 30Vac/dc, split core 0.50 to 150A - 240Vac, split core

Data sheets PDCSY-PM-CS.pdf

Tel: +33 (0) 4 78 45 01 23 Fax: +33 (0) 4 78 45 22 33 web: www.distech-controls.eu

27

Peripheral Programme
PDCSY-RE-PR1 1.5, 3 and 6 kW single-phase Controllers

PDCSY-PS

24Vdc Power Supply

This range of 24 VDC Power Supplies offer advanced protection, selfdiagnostics and self-test facilities, to make installation and commissioning quicker and easier than ever before. 240 VAC and 24 VAC input versions are available, all featuring overcurrent and over-voltage protection, LED indication of a wide range of conditions, an optional alarm relay output for loss of input and on-PCB reset button. The 24 VAC input type is available in two version: 1. PDCSY-PS-24-24DC-1A the input 0 V and the output 0 V are NOT common. 2. PDCSY-PS-24-24DC-E the input 0 V and the output 0 V are common on the PCB. This allows the user a choice, depending on what type of field wiring is installed. FEATURES Advanced LED indication of faults ON-PCB self-test function Polarity independent output SPECIFICATION Supply 240 VAC, 24 VAC and 24 VDC models Output 24 VDC @ 1 A LED indication Power ON, low output voltage, high output voltage, output voltage within limits, reset button pressed, self-test in progress Temperature range 10 to +50C Humidity range 0 to 95%, non-condensing Dimensions PDCSY-PS-240-24DC-1A 104 x 118 x 88 mm PDCSY-PS-24-24DC-1A 104 x 74 x 65 mm PDCSY-PS-240-24DC-E 104 x 74 x 70 mm Weight PDCSY-PS-240-24DC-1A 620 g PDCSY-PS-24-24DC-1A 120 g PDCSY-PS-240-24DC-E 120 g Part code PDCSY-PS-24-24DC-1A PDCSY-PS-24-24DC-E PDCSY-PS-230-24DC-1A Description 24 VAC-24 VDC Output Supply Module - 1 A floating 24 VAC-24 VDC Output Supply Module - grounded 240 VAC-24 VDC Output Supply Module - 1 A

This range of Triac Control Assemblies provide full seamless control of single phase electric heating loads. The controllers incorporate a temperature trip, automatic reset, integral semi-conductor fuses and heatsink. FEATURES 0-10 VDC or 0-5 VDC control input Over temperature protection with auto zero No additional heatsinks required No external 24 V supply required No external RFI filters required SPECIFICATION Input signal Supply Over temp Fault condition Mounting Ambient temp Dimensions Weight Part code PDCSY-RE-PR1-F-1.5 PDCSY-RE-PR1-F-3 PDCSY-RE-PR1-F-6 PDCSY-RE-PR1-F15102 PDCSY-RE-PR1-F15103 PDCSY-RE-PR1-F11307 PDCSY-RE-PR1-F-6-GD 0-5 VDC or 0-10 VDC 230 VAC RMS 10%, 50/60 Hz Trip-in temp. 90C 1C Trip-out temp. 85C 1C Over temp. LED flashes in 0.5 sec pulse bursts Loss of signal LED flashes in 1 sec pulse bursts DIN-rail 65C (maximum operational) PDCSY-RE-PR1-F-1.5 112 x 95 x 75 mm PDCSY-RE-PR1-F-3 112 x 95 x 75 mm PDCSY-RE-PR1-F-6 112 x 95 x 85 mm PDCSY-RE-PR1-F-1.5 280 g PDCSY-RE-PR1-F-3 280 g PDCSY-RE-PR1-F-6 700 g Description Single-phase Controller - 1.5 kW, 6.3 A Single-phase Controller - 3 kW, 12.5 A Single-phase Controller - 6 kW, 25 A Accessories Replacement fuse (1.5 kW) Replacement fuse (3 kW) Replacement fuse (6 kW) Replacement 6 kW guard Data sheet PDCSY-RE-PR1-F.pdf

PDCSY-RE-PR3

12 and 18 kW 3-phase Controllers

Data sheets PDCSY-PS-24-1A.pdf, PDCSY-PS-24-E.pdf, PDCSY-PS-230.pdf

The PDCSY-RE-PR3-DIN-xx range of Thyristor Stacks provides full seamless control of 415V supply loads. They incorporate a temperature trip, automatic reset, alarm output, LED indication (output on) and heatsink. FEATURES 0-10 VDC control input Over temperature protection with auto reset No additional heatsinks required SPECIFICATION Input signal External supply Supply Over temp Fault condition LED indication Mounting Ambient temp Dimensions Weight Part code PDCSY-RE-PR3-DIN-12 PDCSY-RE-PR3-DIN-18 0-10 VDC (control) 24VAC/DC 10%, 50 Hz (load) 3-Phase, 400 VAC RMS 10%, 50 Hz Trip-in temp. 90C 1C Trip-out temp. 85C 1C 24 VAC/DC (as power supply) 24 V alarm terminal normally present, drops to 0 V in the event of over-temp. or loss of external power supply. T1 & T3 LED pulse when output is ON. DIN-rail 40C (max. operational) PDCSY-RE-PR3-DIN-12 217 x 92 x 85 mm PDCSY-RE-PR3-DIN-18 217 x 92 x 107 mm PDCSY-RE-PR3-DIN-12 600 g PDCSY-RE-PR3-DIN-18 960 g Description 3-phase Controller - 12 kW, 16.7 A per phase 3-phase Controller - 18 kW, 25 A

Data sheet PDCSY-RE-PR3-DIN.pdf

28

Innovative Solutions for Greener Buildings

PDCSY-RE-PR3-E

27, 36, 54 and 86 kW 3-phase Controllers

Introduction to EnOcean probes and sensors


The EnOcean series are a complete range of wireless probes and sensors using EnOcean radio technology for a variety of sensing applications such as:

These thyristor Control Assemblies provide full seamless control of 3-phase resistive loads of up to 27, 36, 54 & 86 kW. The controllers incorporate a temperature trip, automatic reset, alarm output, LED indication (output on) and heatsink. FEATURES 0-5 VDC or 0-10 VDC control input Over temperature protection with auto reset No additional heatsinks required No external 24 V supply required

Duct temperature Pipe Contact Temperature Outdoor Temperature Room Temperature and RH Occupancy and Light Detection Door and Window Contact

Energy is taken from the sensor environment in order to pick up and transmit information through radio waves in short distances. Using battery-less technology in building automation reduces the demand for energy consumption and in turn reducing costs. The sensors offer maximum flexibility for refurbishment as there are no wires to re-locate and no drilling or fixing onto the wall. Optimum control can be had as the sensor can be placed where its operation gives the most reliable reading.
SPECIFICATION Input signal 0-5 VDC or 0-10 VDC Supply (control) 24 VAC/DC 10% (by dipswitch) (load) 3-Phase, 400 VAC RMS 10%, 50/60 Hz Over temp Trip-in temp. @ 90C 1C Trip-out temp. @ 85C 1C Fault condition Relay rated at 230 VAC @ 8 A Fault status Phase loss LED flashes in 1.5 sec pulse bursts Sensor loss LED flashes in 0.5 sec pulse bursts Ambient temp 65C (maximum operational) Mounting Panel Dimensions PDCSY-RE-PR3-E-27 150 x 240 x 100 mm PDCSY-RE-PR3-E-36 205 x 155 x 120 mm PDCSY-RE-PR3-E-54 250 x 155 x 120 mm PDCSY-RE-PR3-E-86&105 340 x 232 x 124 mm Weight PDCSY-RE-PR3-E-27 3.0 kg PDCSY-RE-PR3-E-36 3.8 kg PDCSY-RE-PR3-E-54 3.6 kg PDCSY-RE-PR3-E-86&105 6.6 kg Part code PDCSY-RE-PR3-E-27 PDCSY-RE-PR3-E-36 PDCSY-RE-PR3-E-54 PDCSY-RE-PR3-E-86 PDCSY-RE-PR3-E-105 PDCSY-RE-PR3-F11310 PDCSY-RE-PR3-F11511 PDCSY-RE-PR3-F11513 PDCSY-RE-PR3-F11606 PDCSY-RE-PR3-F11610 Description 3-phase Controller - 27 kW, 38 A per phase 3-phase Controller - 36 kW, 50 A 3-phase Controller - 54 kW, 75 A 3-phase Controller - 86 kW, 120 A 3-phase Controller - 105 kW, 146 A Accessories Replacement fuse (27 kW) Replacement fuse (36 kW) Replacement fuse (54 kW) Replacement fuse (86 kW) Replacement fuse (105 kW)

FEATURES High reliability Quick and easy installation No wiring costs Maintenance free Flexibility

SR65AKF

EnOcean Duct Sensors

Battery and wireless air-duct sensor for temperature control in connection with the receiving interfaces SRC-x and higher-graded control systems. Detection of measuring values via the highergraded control system. Transmission to receiver by means of radio telegrams according to EnOcean standard. With integrated temperature sensor and solar energy storage for maintenance-free operation. SPECIFICATIONS Technology EnOcean, STM Transmitting frequency 868.3 MHz Transmitting range approx. 30 m in buildings, approx. 300m upon free propagation Temperature detection: Range 10C to +90C Resolution 0.31 K Absolute accuracy typ. 0.8K Measuring value detection every 100 seconds Sending interval every 100 seconds with changes >1.6K every 1000 seconds with changes <1.6K Energy generator Solar cell, internal goldcap, maintenance-free Enclosure Bottom material PA6, colour white Top cover material PC, colour crystal clear Sensor bushing Stainless steel grade 1.4571, D=7mm Mounting lengths 62 mm / 135 mm / 192 mm / 240 mm / 320 mm/465 mm Protection IP65 according to EN60529 Ambient temperature -25 to +65C Transport -25+65C/ max. 70%rH, non-condensed Weight 140g Part Code SR65AKF62 SR65AKF135 SR65AKF192 SR65AKF240 SR65AKF320 SR65AKF465 315098 Description Duct temperature sensor, 2.44 (62mm) length, wireless (868.3MHz), solar cell powered (optional battery available). Duct temperature sensor, 5.32 (135mm) length, wireless (868.3MHz), solar cell powered (optional battery available). Duct temperature sensor, 7.56 (192mm) length, wireless (868.3MHz), solar cell powered (optional battery available). Duct temperature sensor, 9.45 (240mm) length, wireless (868.3MHz), solar cell powered (optional battery available). Duct temperature sensor, 12.6 (320mm) length, wireless (868.3MHz), solar cell powered (optional battery available). Duct temperature sensor, 18.3 (465mm) length, wireless (868.3MHz), solar cell powered (optional battery available). Accessory Optional battery for wireless sensor - 1.1 Ah 3.6 V 5 AA

Data sheets PDCSY-RE-PR3-E-27, PDCSY-RE-PR3-E-36&54.pdf, PDCSY-RE-PR3-E-86.pdf, PDCSY-RE-PR3-E-105.pdf

Tel: +33 (0) 4 78 45 01 23 Fax: +33 (0) 4 78 45 22 33 web: www.distech-controls.eu

29

Peripheral Programme

SR65TF1

EnOcean Cable Temperature Sensor

SR65

Outdoor Temperature Sensor

Battery and wireless sensor for temperature and fan control in connection with the receiving interfaces SRC-x and higher-graded control systems. Temperature measurement in gaseous media of heating, cooling or airconditioning systems (e.g. fresh air/ exhaust air ducts). Detection of measuring values via the higher-graded control system. Transmission to receiver means of radio telegrams according to EnOcean standard. With integrated temperature sensor and solar energy storage for maintenance-free operation.

by

Battery- and wireless outdoor sensor for temperature control in connection with the receiving interfaces SRC-x and highergraded control systems. Transmission to receiver by means of radio telegrams according to EnOcean standard. With integrated temperature sensor and solar energy storage for maintenancefree operation. SPECIFICATIONS Technology EnOcean, STM Transmitting frequency 868.3 MHz Transmitting range approx. 30 m in buildings, approx. 300 m upon free propagation Temperature detection Range -20C to +60C Resolution 0.31 K Absolute accuracy typ. 0.8 K Measuring value detection every 100 seconds Sending interval every 100 seconds with changes > 1.6 K every 1000 seconds with changes < 1.6 K Energy generator Solar cell, internal goldcap, maintenance-free Ambient temperature -25 to +65C Transport -25 to +65C / max. 70%rH, non-condensed Weight 110g Part code SR65 315098 Description Outdoor temperature sensor, wireless (868.3MHz), solar cell powered (optional battery available). Accessory Optional battery for wireless sensor - 1.1 Ah 3.6 V 5 AA

SPECIFICATIONS Technology EnOcean, STM Transmitting frequency 868.3 MHz Transmitting range approx. 30 m in buildings, approx. 300m upon free propagation Temperature detection: Range -20C to +60C Resolution 0.31 K Absolute accuracy typ. 0.8K Measuring value detection every 100 seconds Sending interval every 100 seconds with changes > 1.6K every 1000 seconds with changes < 1.6K Energy generator Solar cell, internal goldcap, maintenance-free Enclosure Bottom part material PA6, colour white Top cover material PC, colour crystal clear Protection IP65 according to EN60529 Sensor wire 1 m / 2 m / 4 m / 6 m, other lengths on request max. operative temperature PVC/HT: 100C Sensor bushing Stainless Steel Mat. 1.4571 Mounting lengths 50 mm / 100 mm / 150 mm / 200 mm / 250 mm Ambient temperature -25 to +65C Transport -25 to +65C / max. 70% rH, non-condensed Weight 250g Part code SR65TF1 Description "Cable temperature sensor, 39.4"" (1m) length, wireless (868.3MHz), solar cell powered (optional battery available).

ECW

Allure ECW-Sensor

The Allure ECW-Sensor series are wireless and batteryless room temperature sensors specifically designed to communicate with Distech Controls Open-to-Wireless controllers via radio telegrams in accordance with the EnOcean standard. Some models feature a rotary knob for setpoint adjustment, fan speed setting, and a push button for occupancy override. SPECIFICATIONS Technology EnOcean,STM Transmitting frequency 868.3 MHz Transmitting range approx. 30 m in buildings, approx. 300 m upon free propagation Temperature sensor Range 0C to +40C Resolution 0.15 K Absolute accuracy typ. 0.5 K Wake-Up Cylcle Time 1, 10, 100(default) seconds; Jumper selectable Transmit Interval Time 1, 10(default),100; Jumper selectable Energy generator Solar cell, internal goldcap,maintenance-free Enclosure ABS Type PA-765A Ambient temperature 5C to 65C Transport -20C to 57C Relative Humidity 0% to 95% rH, non condensing Weight 180g Part code Allure ECW-Sensor (868) Allure ECW-Sensor-O (868) Allure ECW-Sensor-S (868) Description Open-to-Wireless battery-less space temperature sensor, Enocean 868.3 MHz (Optional battery available)
Open-to-Wireless battery-less space temperature sensor with override, Enocean 868.3 MHz (Optional battery available) Open-to-Wireless battery-less space temperature sensor with setpoint cool/warm, Enocean 868.3 MHz (Optional battery available)

SR65VFG

EnOcean Contact Sensor

Battery-and wireless contact sensor for temperature control in connection with the receiving interfaces SRC-x and higher-graded control systems. For measuring temperature on pipes and arched surfaces. Detection of measuring values via the higher-graded control system. Transmission to receiver by means of radio telegrams according to EnOcean standard. With integrated temperature sensor and solar energy storage for maintenance free operation. SPECIFICATIONS Technology EnOcean, STM Transmitting frequency 868.3 MHz Transmitting range approx. 30 m in buildings, approx. 300 m upon free propagation Temperature detection Range 10C to +90C Resolution 0.31 K Absolute accuracy typ. +/-0.8 K Measuring value detection every 100 seconds Sending interval every 100 seconds with changes > 1.6 K every 1000 seconds with changes < 1.6 K Energy generator Solar cell, internal goldcap, maintenance-free Enclosure Bottom part material PA6, colour white Top cover material PC, colour crystal clear Protection IP65 according to EN60529 Ambient temperature -25 to +65C Transport -25 to +65C/ max. Weight 115g

Part code SR65VFG 315098

Description Surface temperature contact sensor, wireless (868.3MHz), solar cell powered (optional battery available). Accessory Optional battery for wireless sensor - 1.1 Ah 3.6 V 5 AA

Allure ECW-Sensor-SO (868) Open-to-Wireless battery-less space temperature sensor with setpoint cool/warm and override, Enocean 868.3 MHz (Optional battery available) Allure ECW-Sensor-SOF Open-to-Wireless battery-less space temperature sensor with setpoint cool/warm, override and fan (868) speed selector, Enocean 868.3 MHz (Optional battery available) 315098 Optional battery for wireless sensor 1.1 Ah 3.6 V 5 AA

30

Innovative Solutions for Greener Buildings

SR04 rH Series

EnOcean Room Humidity Sensors

SR-MDS Solar

EnOcean 360 Ambient Light Detector

Battery-less radio room sensor for temperature and ventilation control in connection with the receiving interfaces SRC-x and higher-graded control systems. Transmission to receiver by means of radio telegrams according to EnOcean standard. Depending on the type with integrated sensor for humidity and temperature, rotary knob for set point adjustment, presence key. With integrated solar energy storage. Types Available SR04 rH Room sensor humidity/temperature SR04P rH Room sensor with setpoint adjustment SR04PT rH Room sensor with setp. adjustment, presence key SR04P MS rH Room sensor with setp. adjustment, slide switch 0/I SPECIFICATIONS Technology EnOcean, STM Transmitting frequency 868.3 MHz Transmitting range approx. 30 m in buildings, approx. 300 m upon free propagation Humidity sensor Range 0 to 100%RH Resolution 0.4%RH Absolute accuracy 3% range, 30% to 80% Temperature sensor Range 0C to +40C Resolution 0.15K Absolute accuracy typ. 0.4K Measuring value detection every 100 seconds Sending interval every 100 seconds if changes > 0.8K or > 1.6%RH or > 14 angle of rotation or slide switch every 1000 seconds if changes < 0.8 K or < 1.6%RH or < 14 angle of rotation Energy generator Solar cell, internal goldcap,maintenance-free Enclosure ABS (ASA), pure white similar to RAL9010 Protection IP30 according to EN60529 Ambient temperature 5 to +65C Transport -25 to +65C / max. 70%RH, non-condensed Weight 50g Part code SR04 RH SR04P RH SR04PT RH SR04 MS RH 315098 Description Room humidity and temperature sensor, wireless (868.3MHz), solar cell powered (optional battery available). Room humidity and temperature sensor, with setpoint adjustment, wireless (868.3MHz), solar cell powered (optional battery available). Room humidity and temperature sensor, with setpoint adjustment and override button, wireless (868.3MHz), solar cell powered (optional battery available). Room humidity and temperature sensor, with setpoint adjustment and slide switch (ON/OFF), wireless (868.3MHz), solar cell powered (optional battery available). Accessory Optional battery for wireless sensor - 1.1 Ah 3.6 V 5 AA

The battery- and wireless ceiling multi sensor is designed for movement detection in room or office spaces. In addition, the sensor detects the ambient brightness in rooms. Radio telegrams according to EnOcean standard. With integrated solar energy storage for maintenace-free operation. Functions of the MDS: Occupancy detection 360, Integrated light sensor 0-512Lux, Monitoring of charging voltage of the energy storage SPECIFICATIONS Technology EnOcean, STM Transmitting frequency 868.3 MHz Transmitting range approx. 30 m in buildings, approx. 300 m upon free propagation Movement detection PIR passive infrared Brightness detection 0 to 512 Lux Measuring value detection every 100 s Sending interval directly with movement detection every 100 s if brightness changes > 10 Lux or with switching off the movement detector every 1000 s if brightness changes < 10 Lux or if no movement is detected Energy generator Solar cell, internal goldcap, maintenance-free Enclosure PC V0, colour pearl white similar to RAL1013 Protection IP50 Ambient temperature 10 to 55C Transport -10 to 65C 70% rH, non-condensed Weight 120g Part code SR-MDS Solar 315098 Description 360 degree motion / 0 to 512 lux ambient light detector, wireless (868.3MHz), solar cell powered (optional battery available). Accessory Optional battery for wireless sensor - 1.1 Ah 3.6 V 5 AA

41-xxx

EnOcean 360 Ceiling Multi-Sensor

The model 41-xxx series detector is a range of presence detectors based on wireless technology that sends an RF telegram to a receiver module. Lighting is turned on manually by the wireless switch and the detector ensures that lighting remains switched on as long as moving people are detected. Via the wireless receiver the required time delay is set, which ensures that the light remains on for a period after the last person has left. SPECIFICATIONS - 41-580 Power supply Lux-level for function Guidance Installation height Detection range Protection Temperature range Type of signal/range RF signal range Solar cell, zero-energy. > 80 lux measured by luxmeter. 25 W bulb 2.5 - 4m 360, 7 12 m IP20 +5 C ... +50 C indoor use RF signal EnOcean 868 MHz, <10 mW 100 m in free range / 30 m in buildings

SRW01

EnOcean Door / Window Contact

Battery-less radio window contact for status monitoring of windows and doors in connection with the receiving interfaces SRC-x and higher-graded control systems. Satus monitoring of windows and doors. Transmission to the receiver by means of radio telegrams based on the EnOcean standard. With integrated solar energy storage. SPECIFICATIONS Technology EnOcean, STM250 Transmitting frequency 868.3 MHz Transmitting range approx. 30 m in buildings, approx. 300 m upon free propagation Measuring value detection change of internal reed contact Sending interval If contact changes or every 5 to 30 minutes Energy generator Solar cell, internal goldcap, maintenance-free Housing ABS, colour white similar RAL9003 Protection IP40 according to EN60529 Ambient temperature -25 to +65C Transport -25 to +65C / max. 70%rH, non-condensed Weight 40g Part code SRW01 315098 Description Door/window contact, wireless (868.3MHz), solar cell powered. Accessory Optional battery for wireless sensor - 1.1 Ah 3.6 V 5 AA

SPECIFICATIONS - 41-580 Supply voltage Power consumption RF system transmitter Lux range Lux range off Hysteresis Time delay Transmitter frequency Transmitter output Transmitter rate of recurrence RF range Protection Cable bush Ambient temperature Part code 41-580 41-301 315098 230 VAC 10 % 50 Hz, 24 VAC/DC 10 % 1 W (230 VAC) 0.5 VA (24 V) EnOcean STM100 10 to 1000 Lux LUX is turned towards max to position off, no daylight blocking. > +10 % 1 to 30 minutes, with daylight blocking 10 s to 30 minutes, no daylight blocking 868 MHz < 10 mW On standby once per approx. 100 sec. Immediately when PIR activation timer set 100 m in open space/free line of vision, approx. 30 m in buildings IP 20 2 x 12 mm -5 C to +50C

Description 360 degree motion / AUTO OFF, wireless (868.3 MHz), solar cell powered.
360 degree motion / 10 to 1000 Lux ambiant light detector, wireless (868.3 MHZ), 230 VAC OR 24 VAC/DC Accessory Optional battery for wireless sensor - 1.1 Ah 3.6 V 5 AA

Tel: +33 (0) 4 78 45 01 23 Fax: +33 (0) 4 78 45 22 33 web: www.distech-controls.eu

31

Peripheral Programme

SR65 LI

Outdoor Light Sensor

SRE Repeater

Repeater

Battery and wireless outdoor light sensor for detection of brightness in outdoor applications. Shadowing and lighting control in connection with the receiver interfaces SRCx and higher control systems. Transmission to receiver by means of radio telegrams according to EnOcean standard. With integrated light sensor and solar energy storage for maintenance free operation. SPECIFICATIONS Technology EnOcean, STM Transmitting frequency 868.3 MHz Transmitting range approx. 30 m in buildings, approx. 300 m upon free propagation Temperature detection Range 1 300 30000 Lux Resolution 17 Lux Range 2 600 to 60000 Lux Resolution 234 Lux Measuring value detection every 10 seconds Sending interval every 10 seconds with changes > 468 Lux in range 1 and > 1170 Lux in range 2 every 1000 seconds with changes < 468 Lux in range 1 and < 1170 Lux in range 2 Energy generator Solar cell, internal goldcap, maintenance free Enclosure Bottom part material PC, colour grey Top cover material PC, colour crystal clear Protection IP54 according to EN60529 Ambient temperature 20 to +55C Transport 20 to +55C / max. 70%rH, non condensed Weight 60g Part code SR65LI 315098 Description Outdoor Light sensor, wireless (868.3MHz), solar cell powered (optional battery available). Accessory Optional battery for wireless sensor - 1.1 Ah 3.6 V 5 AA

The repeater is designed for low-level amplification of telegrams between EnOcean sensors and receivers. Typically, the repeater is used if the sensor location is outside the receiving range or if there are range problems between sender and receiver with existing installations (e.g. building of walls, moving of furnitures /cupboards). SPECIFICATIONS Power supply Power consumption Antenna Transmitter frequency Transmitting power Transmitting range Clamps Cable entry Housing Protection Ambient temperature Humidity Storage temperature Weight Part code SRE Repeater 230 VAC 50/60 Hz max. 2 VA Internal or external sending/receiving antenna (depending on the type used) 868 MHz < 10 mW approx. 30 m in buildings Terminal screw max. 1.5mm M20, for wire with max. D=8mm PA6, Colour pure white IP42 according to EN60529 20 to 60C 0 to 75% rH, without dew permeation 20 to 70C 130g (without external antenna)

Description Low-level amplificator for sensors with location outside receiving range, 230 VAC.

EPM300

Measurement Tools

Field strength measuring instrument for finding optimal mounting place for transmitter and receiver. With integrated repeater for test installations. SPECIFICATIONS Receiving-/Trans. Frequency Housing size Battery Ambient conditions Storage conditions Protection Weight 868.3 MHz 110 x 70 x 25 mm AA/LR06 cell 0 to +45C / 0 to 95% rH) -15 to +65C / 0 to 98% rH IP54 85g (w/o battery)

SR65 DI

EnOcean Digital Input (dry input)

The module SR65 DI has one digital input for dry contacts by which the switch status can be evaluated. The status of the contact (opened/closed) is transmitted by wireless signal to a receiver (SRCx), which provides this information to a controller for data logging. SPECIFICATIONS Technology Transmitting frequency Transmitting range Digital input Clamps Power supply Enclosure Protection Ambient temperature Transport Weight Part code SR65 DI EnOcean, STM 868.3 MHz With state changes immediately, in addition periodically every 1000 seconds 2 wire for dry contacts contact current max. 0.5 mA contact resistance max 1 k Terminal screw max. 1.5 mm Battery 3.6 V Type LS14250 PA6,Colour white IP65 25 to 65C 25 to +65C / max. 70% rH, non condensed 110g

Part code EPM 300

Description Field strength measuring instrument (2 point) for wireless signals at 868.3 MHz

INT-ENOCEAN

INT-EnOcean

Battery-less radio light switch designed to communicate with Distech Controls Open-to-Wireless controllers via radio telegrams in accordance with the EnOcean standard. SPECIFICATIONS Technology Transmitting frequency Transmitting range Energy generator Ambient temperature Transport Relative Humidity Weight EnOcean,STM 868.3 MHz approx. 30 m in buildings, approx. 300 m upon free propagation Electrodynamic Energy Harvester -25C to 65C -25C to 65C 5% to 95% rH, non condensing 58g

Description Digital input (2-wire dry contact) for potential-free contacts, wireless (868.3 MHz), battery powered.

Part code INT-ENOCEAN

Description EnOcean switch

32

Innovative Solutions for Greener Buildings

Introduction to Wireless Technology


SonNet, the revolutionary family of wireless sensing devices
HOW SonNet WORKS

PDCSY-RF-SSK

Site Survey Kit (SSK)

SonNet employs the 802.15.4 wireless standard, and uses the 2.4GHz ISM band which features a choice of 16 channels and direct sequence spread spectrum techniques to reduce the effects of interference. To ensure a robust network, a self-healing tree topology is used, which eliminates concerns with reception and reliability often associated with existing point-to-point wireless systems. If a sensor detects a problem with the signal, it will automatically re-route to find the strongest available alternative path to the receiver.
ROUTER SENSOR NODE

THE SITE SURVEY KIT It is comprised of a receiver RF-RXSS which is used in conjunction with the RF-PS-500 site survey routers, RFHHT hand-held monitor and RF TS-900 nodes. Routers are used to route signals from battery powered nodes and other routers to the receiver module, where the signal strength of a direct path is not sufficient for reliable communications. DATA TRANSMITTION Data is transmitted back to the receiver at configurable time intervals, or on a configurable change in measured value. Each sensor retains these configurations if the battery becomes discharged or requires replacement. THE SSK RECEIVER Automatically selects which of the 16 transmission channels available gives the best radio network performance, taking into account both signal strength and interference levels from adjacent channels and equipment (such as Wi-Fi etc.) The SSK hand-held monitor, nodes and routers automatically find the best path back to the receiver, which may be directly to the receiver or via parent routers.

SELF-HEALING TREE TOPOLOGY

RECEIVER

ROUTER

ROUTER

SENSOR NODE

SENSOR NODE

Connected Re-Routed Connection


RECEIVER

Connection Lost

RECEIVER

Note: The receiver and routers can each support a maximum of 16 directly connected child devices. A router can support a maximum of 8 battery powered EDs, plus up to 8 routers. A receiver can have a maximum of 12 directly connected EDs, while a router can have a maximum of 8 directly connected EDs. If no EDs are directly connected a maximum of 16 routers can be directly connected. There can be a maximum depth of 8 layers of routers in a network and a maximum of 50 nodes per network with the PDCSY-RF-RX series of receivers, or 150 with the PDCSY-RF-RXS series.
ROUTER SENSOR NODE

Part code PDCSY-RF-SSK

Description Site Survey Kit Site Survey Kit (SSK) - containing: 4 sensor nodes, 2 routers, receiver, hand-held monitor and power chargers for the rechargeable batteries (Individual units) Sensor End Device (rechargeable) Plant Router (rechargeable) Hand-held Tool Site Survey Receiver

PDCSY-RF-TS-900 PDCSY-RF-PS-500 PDCSY-RF-HHT PDCSY-RF-RXSS

EASY INTEGRATION
Connected

Integration to existing systems is easily achieved by installing receiver modules into the network and terminating them as standard analogue inputs. By using the PDCSY-RF-RXS Network Receiver Modules to integrate through EC-NetAX networks, further reducing controller point count and total system cost.
Connection Lost
RECEIVER

Re-Routed Connection

Data sheets Please contact our Customer Services Team or visit www.distech-controls.eu for datasheets

NETWORK SECURITY

All SonNet devices use unique network identifiers. Only devices with the correct network ID will be allowed to join the network. The ID used by standard system devices is different from the ID used for SSK devices. Hence, SSK devices cannot join a standard system network and vice versa. When a SonNet system network has been formed, it can be locked to prevent any unauthorised devices joining, even if they are SonNet devices. The CMS or EC-NetAX driver can be used to authorise extra SonNet system devices if required. All data transmitted by SonNet devices is encrypted.
BENEFITS

PDCSY-RF-RS

Battery Powered Sensors (EDs)

BATTERY POWERED SENSORS (EDS) Sensor nodes are used in conjunction with the PDCSY-RF-RX20, PDCSY-RF-RX40 or PDCSY-RF-RXS receiver units, and if required (depending on installation topography), the PDCSY-RF-RR series of routers. Data is transmitted back to the receiver at configurable time intervals, or on a configurable change in measured value. Each sensor retains these configurations if the battery becomes discharged or requires replacement. The sensors automatically find the best path back to the receiver, which may be directly to the receiver or via parent routers. BATTERY POWERED NODES ARE AVAILABLE IN FOUR FORMATS: Space mounting temperature, with setpoint and momentary switch options Space mounting RH&T, with setpoint and momentary switch options Plant mounting temperature Plant mounting RH&T

Lower installation costs Easy to install and commission Time saving installation Energy saving through better control Proven 802.15.4 low power network Self-healing tree topology Up to 5-year battery life Simple to integrate analogue receiver modules Site Survey Kit (SSK) CMS software for configuration/monitoring Complete range of sensor types Industry-leading quality and support

FEATURES

Tel: +33 (0) 4 78 45 01 23 Fax: +33 (0) 4 78 45 22 33 web: www.distech-controls.eu

33

Peripheral Programme
SPECIFICATION Radio Output: Frequency 2.4GHz, 16 channels, direct-sequence spread spectrum Compliance IEEE 802.15.4-2006 Aerial Characteristics: Space Gain 1.2dBi, VSWR 1.5:1 Plant Gain 2.0dBi, VSWR 2:1 Data Encryption: AES 128 Power Output: 0dBm Accuracy: Temperature 0.3C Optional RH 3% RH Battery Type: Space 3.6V AA 2.4Ah Li-SOCl2, non-rechargeable Plant 3.6V 2.1Ah 2/3 A Li-SOCl2, non-rechargeable Battery Life: >3 years (depending on configuration) Plant Sensor Types: Duct, outside air, outside air with solar radiation shield, immersion, strap-on and flying lead Part code Description

Part code PDCSY-RF-RR-900 PDCSY-RF-RR-300 PDCSY RF-RR-T-911 PDCSY RF-RR-T-322 PDCSY RF-RR-T-341 PDCSY RF-RR-T-351 PDCSY RF-RR-T-331 PDCSY RF-RR-T-322 PDCSY RF-RR-T-555-2 PDCSY RF-RR-T-555-5 PDCSY RF-RR-R-911 PDCSY RF-RR-R-622 PDCSY RF-RR-R-631 PDCSY RF-RR-R-632 -MS -SP -MS-SP

Description Routers Router (space housing) Router (plant housing) Router Sensors Space Temp. Sensor/Router * Duct Sensor/Router - 150mm probe Router Immersion Sensor - 150mm probe Router Clamp-on Sensor Router Outside Air Sensor Router Outside Air Sensor c/w Rad Shield Router Flying Lead Sensor - 2m Router Flying Lead Sensor - 5m Router Space Humidity & Temp. Sensor * Router Duct Humidity & Temp. Sensor Router Wall Humidity & Temp. Sensor Router Outside Humidity & Temp. Sensor Momentary switch interface ** Set-point adjuster interface Momentary override & set-point **

End Sensing Devices PDCSY-RF-RS-T-911 Space Temperature Sensor * PDCSY-RF-RS-T-322 Duct Sensor - 150mm probe PDCSY-RF-RS-T-341 Immersion Sensor - 150mm probe PDCSY-RF-RS-T-351 Clamp-on Sensor PDCSY-RF-RS-T-331 Outside Air Sensor PDCSY-RF-RS-T-332 Outside Air Sensor c/w rad. sheild PDCSY-RF-RS-T-555-2 Flying Lead Sensor - 2m PDCSY-RF-RS-T-555-5 Flying Lead Sensor - 5m PDCSY-RF-RS-R-911 Space Humidity & temp. Sensor * PDCSY-RF-RS-R-622 Duct Humidity & temp. Sensor PDCSY-RF-RS-R-631 Wall Humidity & temp. Sensor PDCSY-RF-RS-R-632 Outside Humidity & temp. Sensor * Sensor Options for -911 only (add to part code) -MS Momentary switch interface * * -SP Set-point adjuster interface -MS-SP Momentary override & set-point * * Data sheets Please contact our Customer Services Team or visit www.distech-controls.eu for datasheets * * The -MS switch option is momentary in its physical action, but latching in its radio output. When the momentary switch is pressed, the current output status is inverted (TRUE goes to FALSE or FALSE goes to TRUE) and stays in the new state until the switch is pressed again. Please allow for this action in the controller strategy to achieve the required control action.

* Sensor/Router Options for -911 only (add to part code)

Data sheets Please contact our Customer Services Team or visit www.distech-controls.eu for datasheets * * The -MS switch option is momentary in its physical action, but latching in its radio output. When the momentary switch is pressed, the current output status is inverted (TRUE goes to FALSE or FALSE goes to TRUE) and stays in the new state until the switch is pressed again. Please allow for this action in the controller strategy to achieve the required control action.

PDCSY-RF-RX
SYSTEM RECEIVER

System Receiver

PDCSY-RF-RR

24V Powered Routers

The PDCSY-RF-RX20 or PDCSY-RF-RX40 receiver collects data from all other devices on the radio network, including measurements from sensors, link quality for all links formed in the network, battery levels for all battery powered devices, hours run for all devices and the current status of all devices. A USB socket is provided for connection to a PC or laptop running the SonNet CMS software. Note: Each receiver can support a maximum of 16 children, which can consist of a maximum of 12 battery powered nodes and 4 routers, or up to 16 routers if there are no battery powered nodes. RECEIVERS ARE AVAILABLE IN TWO FORMATS: PDCSY-RF-RX20 - 20 x 0-10Vdc analogue outputs PDCSY-RF-RX40 - 40 x 0-10Vdc analogue outputs SPECIFICATION Radio Output: Frequency 2.4GHz.16 channels, direct-sequence spread spectrum Compliance IEEE 802.15.4-2006 Aerial Characteristics: Gain: 2.0dBi VSWR: 2:1 Data Encryption: AES 128 Power Output: +10dBm Analogue Outputs: PDCSY-RF-RX20 20 x 0-10Vdc analogue outputs @10mA max. each PDCSY-RF-RX40 40 x 0-10Vdc analogue outputs @10mA max. each Output ranges: Temp. 10 to +70C (14 to 158F) RH 0 to 100% Setpoint 0 to 100% Switch 0Vdc = OFF, 10Vdc = ON Power Supply: 24Vac/dc Housing: DIN-rail, 203 x 104 x 38mm (W,H,D) (7.99 x 4.09 x 1.5) excluding aerial Part code PDCSY-RF-RX20 PDCSY-RF-RX40 PDCSY-RF-RS PDCSY-RF-RP PDCSY-RF-AERIAL-PM2 PDCSY-RF-AERIAL-PM5 Description Receiver Modules 3-phase Controller - 36 kW, 50 A 3-phase Controller - 54 kW, 75 A Accessory Battery for space sensors Battery for plant sensors Aerial extension c/w bulk head fitting, 2m (6.56 ft) Aerial extension c/w bulk head fitting, 5m (16.40 ft)

24V POWERED ROUTERS These routers are used in conjunction with the PDCSY-RF-RX20, PDCSY-RF-RX40 or PDCSY-RF-RXS receiver units, and PDCSY-RFRS series of battery powered radio sensors, and are used to route signals from battery powered nodes and other routers to the receiver module, where the signal strength of a direct path is not sufficient for reliable communications. Routers automatically find the best path back to the receiver, which may be directly to the receiver or via other parent routers. Note: Each router can support a maximum of 16 children, which can consist of a maximum of 8 battery powered nodes and 8 routers, or up to 16 routers if there are no battery powered nodes. Consideration should be given to network planning for redundancy in case of router failure or damage. 24V POWERED ROUTERS ARE AVAILABLE IN FIVE FORMATS: Space mounting temperature, with setpoint & momentary switch options Space mounting RH&T, with setpoint and momentary switch options Plant mounting router, no sensor functions Plant mounting temperature Plant mounting RH&T

Frequency 2.4GHz, 16 channels, direct-sequence spread spectrum Compliance IEEE 802.15.4-2006 Aerial Characteristics: Space Gain 1.2dBi, VSWR 1.5:1 Plant Gain 2.0dBi, VSWR 2:1 Data Encryption: AES 128 Power Output: +10dBm Accuracy: Temperature 0.3C (0.54F) Optional RH 3% RH Power Supply: 24Vac/dc Plant Router Types: Duct, outside air, outside air with solar radiation shield, immersion, strap-on and flying lead

SPECIFICATION Radio Output:

Data sheets Please contact our Customer Services Team or visit www.distech-controls.eu for datasheets

34

Innovative Solutions for Greener Buildings

PDCSY-RF-RXS

Network Radio Receiver, EC-Net AX TM Option Card

PDCSY-RH-600

Duct, Wall & Outside Mount RH & T Sensors

Following on from the success of the SonNet wireless sensor system, the PDCSY-RF-RXS receivers allow quick and seamless integration with Distech Controls range of EC-BOS AX controllers, with all supported BMS protocols, such as BACnet, LonTalk and ModBus. The integral web interface allows an engineer to not only gather measurement data from SonNet wireless devices but perform radio network management services such as auto-commissioning of SonNet wireless devices and setting device configuration parameters. A serial cable is supplied for connecting the PDCSY-RF-RXS to the BMS controller. 2 VERSIONS OF THE RECEIVER ARE AVAILABLE PDCSY-RF-RXS DIN rail mounted housing with serial connection to COM1 or COM2 of a JACE PDCSY-RF-RXS-N internally mounting JACE option card SOFTWARE SCREENSHOTS SonNet Router Properties View

The new PDCSY-RH-600 range of humidity and temperature sensors offer the latest technology high precision and accuracy RH & T element, and installed in our new revised robust 600 series housing. The housing has an added benefit of being easy to install with the new hinged lid, which can also be screwed closed to make the unit tamperproof. An optional multi-line backlit LCD display is available, along with a direct PTC/NTC sensing element (when this option is required, the type of element must be specified at the time of ordering). Output signals of 0-10Vdc, 0-5Vdc or 4-20mA (loop or externally powered) for all measured values and RH are available as standard. FEATURES High stability and reliability Snap-fit cover Fully configurable LCD display option. Please contact the Customer Service Team for more information SPECIFICATION Active Outputs: Voltage 0-10Vdc @ 4k7 min, 0-5Vdc @ 4k7 min Current 4-20mA @ 250 min Optional Passive Output: PTC/NTC Element any resistive type* Output Ranges: RH 0-100% Temp. 20 to +50C (4 to +122F) Enthalpy 20 to +250 kJ/kg (8.59 to +107.48 Btu/lb) Dewpoint 50 to +50C (58 to +122F) RH Accuracy: PDCSY-RH-6xx-AH 2% (20 to 80%RH) PDCSY-H-6xx 3% (20 to 80%RH) Long term stability: <0.5% RH p.a. Temp. Accuracies: 0.3C (0.54F) (20 to 40C / 68 to 104F) Power Supply: 0-10Vdc 12 - 26Vac or 16 - 26Vdc @ 60mA max 4-20mA 20 - 26Vdc only @ 70mA max Ambient: Temp. 10 to 50C (14 to 122F) RH 0 to 95% RH, non-condensing Housing material: ABS (flame retardant) Protection: PDCSY-RH-622 IP65 PDCSY-RH-632 IP65 PDCSY-RH-631 IP54 Housing dimensions: 116 x 106 x 52mm (4.57 x 4.17 x 2.05) Probe dimensions: Duct 210 (8.27) x 19mm (0.75) dia. Wall 90 (3.54) x 19mm (0.75) dia. Shield dimensions (RH-632): 200 x 118mm dia. Weights: Duct 240g (0.53lb) Wall 220g (0.49lb) Outside 1.16kg (2.56lb)

SonNet Receiver Actions Menu

SPECIFICATION Radio Output: Frequency 2.4GHz 16 channels, automatically selected Direct-sequence spread spectrum Compliance IEEE 802.15.4-2006 Aerial Characteristics: Gain 3.0dBi VSWR <2:1 Data Encryption: AES 128 Power Output: +10dBm Power Supply: 24Vdc 15% 24Vac 15%, 50/60 Hz Serial communications: USB 2.0 Serial 9-pin RS-232 Environmental: Operating Temp. 10 to +50C (14 to 122F) RH 0 to 90%, non-condensing Storage Temp. 10 to +80C (14 to 176F) RH 0 to 90%, non-condensing Dimensions: 100mm x 70mm x 58mm (3.94 x 2.76 x 2.28) Part code PDCSY-RF-RXS PDCSY-RF-RXS-N PDCSY-RF-AERIAL-PM2 PDCSY-RF-AERIAL-PM5 PDCSY-RF-SERIAL Description DIN-rail Mounted Network Radio Receiver Internally Mounted Network Radio Receiver Aerial extension c/w bulk head fitting - 2m (6.56 ft) Aerial extension c/w bulk head fitting - 5m (16.40 ft) Accessory Serial cable 1.8m (6 ft) Data sheets: PDCSY-RF-RXS.pdf, PDCSY-RF-RXS-N.pdf

Part code PDCSY-RH-622-AH PDCSY-RH-622 PDCSY-RH-622-EN PDCSY-RH-631-AH PDCSY-RH-631 PDCSY-RH-631-EN PDCSY-RH-632-AH PDCSY-RH-632 PDCSY-RH-632-EN -T -LCD PDCSY-DPA

Description Duct RH & T Transmitter (2%) RH & T Transmitter (3%) Enthalpy & Dewpoint Transmitter* Wall RH & T Transmitter (2%) RH & T Transmitter (3%) Enthalpy & Dewpoint Transmitter* Outside RH & T High Accuracy Transmitter (2%) RH & T Transmitter (3%) Enthalpy & Dewpoint Transmitter* Suffixes (add to part code) Direct resistive temperature output Integral LCD display Accessory Duct probe adjustment flange (for RH-622 only) Data sheet PDCSY-RH-600.pdf

*Note: 1. -T version uses a thermistor element for direct measurement of temperature. Please specify thermistor type when ordering. 2. Please see Thermistor Types and Compatibility Chart at end of catalogue. 3. PDCSY-RH-6xx-EN versions only output enthalpy and dewpoint values.

Tel: +33 (0) 4 78 45 01 23 Fax: +33 (0) 4 78 45 22 33 web: www.distech-controls.eu

35

Peripheral Programme

PDCSY-RH-1000

Space RH & T Sensor

Completely revised for the 1000 series space housing, and using the latest high accuracy RH & T element, the PDCSY-RH-1000 has options such as setpoint adjustment, momentary switch and fan speed selection, together with a multi-line backlit LCD display. A 0-10Vdc override status input option is also available, allowing occupancy indication on the display. 0-10Vdc, 0-5Vdc or 4-20mA (loop or externally powered) outputs for all measured values are available as standard. A directly connected passive thermistor temperature output is also available, as an alternative to the standard active temperature output. FEATURES High stability and reliability Designed to be aesthetically pleasing Blends into the fabric of any building Developed using customer feedback and involvement Fully configurable LCD display option. Please contact the  Customer Services Team for more information. SPECIFICATION Active Outputs: Voltage 0-10Vdc @ 4k7 min, 0-5Vdc @ 4k7 min Current 4-20mA @ 250 min Optional Passive PTC/NTC Element Any restrictive type* Outputs: Setpoint 2-wire 11-1k/0-10k, linear Override VFC Fan Speed 3 position Resistive 5 position Resistive Output Ranges: RH 0-100% Temperature 0 to 40C (32 to 104F) as standard Enthalpy 20 to +250 kJ/kg (8.59 to +107.48 Btu/lb Dewpoint 50 to +50C (58 to +122F) Power Supply: 0-10Vdc 12 - 26Vac or 16 - 26Vdc @ 60mA max 4-20mA 20 - 26Vdc only @ 70mA max Temp. Accuracies: 0.3C (0.54F) ( 20 to 40C / 68 to 104F) Ambient: Temperature 0 to 50C (32 to 122F) RH 0 to 95% RH, non-condensing Housing material: ABS (flame retardant) Dimensions: 115 x 85 x 28mm (4.53 x 3.35 x 1.10) Weight: 180g (0.40 lb) PDCSY-RH-SH humidistats are designed for the on/off control of humidification and dehumidification equipment, or the initiation of alarms or override controls. High quality sensing elements ensure accurate measurement and switching Part code PDCSY-RH-1000-AH PDCSY-RH-1000 PDCSY-RH-1000-EN -T -SP -MS -FS3 -FS5 -LCD PDCSY-GASKET Description RH & T High Accuracy Transmitter (2%) RH & T Transmitter (3%) Enthalpy & Dewpoint Transmitter* Suffixes (add to part code) Direct resistive temperature output 2-wire, 11-1k/0-10k setpoint Momentary switch 3-speed fan switch 5-speed fan switch Integral LCD display for RH and temp. Accessory Insulating gasket (pack of 10) Data sheet PDCSY-RH-1000.pdf

differential.

PDCSY-RH-SH

Humidistats

FEATURES Single and 2-stage units available (space types only) Duct or space mounted units SPECIFICATION Case construction: Operating range: ABS 30-100% RH

Differential (per stage): 4% RH Stage differential: 2 to 15% RH Switch rating: Duct 15(8)A @ 240Vac Room 5(0.2)A @ 250Vac Cable entry: 20mm gland PG11 thread (not supplied) Protection: PDCSY-RH-SH-xR IP20 PDCSY-RH-SH-xD IP65 PDCSY-RH-SH-1DE IP20 Dimensions: PDCSY-RH-SH-xR Housing 115 x 35 x 70mm (4.53 x 1.38 x 2.76) PDCSY-RH-SH-xD Housing 108 x 72 x 72mm (4.25 x 2.83 x 2.83) Probe 19mm (0.75) dia. x 225mm (8.86) long Weight: 300g (0.66 lb)

Part code PDCSY-RH-SH-1R PDCSY-RH-SH-1RE PDCSY-RH-SH-2R PDCSY-RH-SH-1D PDCSY-RH-SH-1DE

Description Room Humidistats Single-stage, concealed setpoint adjust. Single-stage,exposed setpoint adjust. 2-stage, concealed setpoint adjust. Duct Humidistats Single-stage, concealed setpoint adjust. Single-stage, exposed setpoint adjust. Data sheet PDCSY-RH-SH-xR.pdf, PDCSY-RH-SH-xD.pdf

PDCSY-SD-821

Duct Smoke Detector

The PDCSY-SD-821 provides relay outputs on the detection of smoke or fault conditions. The alarm output relay can be either manual or auto reset depending on application type. FEATURES Manual or auto reset Fault relay output Self-test feature SPECIFICATION Supply voltage: Power consumption: Relay outputs (smoke & fault): Minimum duct size: Maximum duct size: LED indication: Reset: Housing: Probe: Ambient range: Protection: Weight: Part code PDCSY-SD-821 24Vac/dc, 20% 50mA max. SPST 2A @ 48V 100 x 320mm (3.94 x 12.60) 450 x 450mm (17.72 x 17.72) On in alarm Manual or auto reset, selectable Material ABS (flame retardant type VO) Dimensions 55 x 90mm (2.17 x 3.54) dia. Material Plastic Dimensions 300 x 20mm (11.81 x 0.79) diameter Temperature 10 to 40C (50 to 104F) Ambient 20 to 80% non-condensing IP65 350g (0.77 lb)

*Note: 1. -T version uses a thermistor element for direct measurement of temperature. Please specify thermistor type when ordering. 2. When using the -T option, they are not compensated for internal heating. 3. Please see Thermistor Types and Compatibility Chart at end of catalogue. 4. PDCSY-RH-1000-EN outputs only enthalpy and dewpoint values.

Description Duct Smoke Detector Data sheet PDCSY-SD-821.pdf

36

Innovative Solutions for Greener Buildings

PDCSY-ST

General Purpose Thermostats

PDCSY-ST-FRE

Capillary Frost Thermostats

The revised range of thermostats, are well suited for a number of applications of temperature control or safety cut-out in pipe work systems, calorifiers, duct work systems, green houses and many other installations. They all have the set-point adjustment under the cover to prevent unauthorised tampering. They are available in two types; CONTROL THERMOSTATS (AUTO RESET) - with an adjustable set point, adjustable differential and auto reset, which provides a switched output to a heater or controller. SAFETY THERMOSTATS (MANUAL RESET) - with an adjustable set-point, fixed differential and manual reset, which provides high limit cut-out on boilers etc. FEATURES Robust housing Immersion sensors supplied with pocket Ideal for many applications Volt free contacts Concealed adjustment SPECIFICATION Switch rating: 24 to 250Vac @ 16(4)A Sensing element: Liquid filled copper element Housing: Material ABS UL94 V0 (flame retardant) Dimensions: PDCSY-ST-S-01A 86.5 x 38 x 53 (3.41 x 1.50 x 2.09) Others 108 x 70 x 72mm (4.25 x 2.76 x 2.83) Ambient: Temperature 35 to 65C (31 to 149F) RH 0 to 95% RH, non-condensing Capillary length (ST-C): 1.5m (4.92ft) Duct probe (ST-D): 280mm (11.02) x 16mm (0.63) dia. Immersion pocket (ST-I): Dimensions 130mm (5.12), thread BSPT Material Nickel plated brass/copper Conformity: CE marked Protection: PDCSY-ST-D-01A IP54 PDCSY-ST-S-01A IP30 Others IP65 (auto reset types) Manual reset IP43 Weights: Capillary 340g (0.75lb) Duct 700g (1.54lb) Immersion 580g (1.28lb) Wall 480g (1.06lb) Strap-on 250g (0.55lb) Part code PDCSY-ST-C-01M PDCSY-ST-D-01A PDCSY-ST-D-02A PDCSY-ST-D-03A PDCSY-ST-D-04M PDCSY-ST-I-01A PDCSY-ST-I-02M PDCSY-ST-I-03M PDCSY-ST-W-01A PDCSY-ST-S-01A Description Capillary 50 to 140C (122 to 284F) Duct 35 to +35C (31 to 95F) 0 to 90C (32 to 194F) 30 to +30C (22 to 86F) 0 to +90C (32 to 194F) Immersion 0 to 120C (32 to 248F) 0 to 110C (32 to 230F) 20 to 90C (68 to 194F) Wall 30 to +30C (22 to 86F) Strap-on 0 to 90C (32 to 194F) Accessory PDCSY-ST-IMM-PKT Optional stainless steel pocket (ST-I range only) Data sheet PDCSY-ST-x.pdf Auto Reset Auto Reset Auto Reset Manual Reset Manual Reset Auto Reset Auto Reset Auto Reset Manual Reset Manual Reset

The PDCSY-ST-FRE range of Frost Thermostats provide a switch output based on the average temperature detected along a two or six metre capillary sensor. A common application is for frost protection on fresh air intakes or airconditioning systems, to prevent the icing up of filters, fans and coils. The capillary is fixed in a matrix across the duct, in a position downstream of the pre-heater or frost coil. FEATURES Easy adjustment of setpoint Setting indicator IP65 option Pre-set thermostats to speed commissioning time SPECIFICATION Control range Differential Switch rating Housing material Housing dimensions Capillary Dimensions Protection Weight 30 to +10C 2 to 16C 230 VAC @ 24 (10) A 24 VDC @ 3 A ABS 86 x 75 x 44 mm Material Copper Charge Vapour Max. temp. 150C 2m or 6m x 1.8mm dia. IP44 or IP65 476 g

Note: All these thermostats include six capillary fixing clips as standard. Part code PDCSY-ST-FRE1 PDCSY-ST-FRE2 PDCSY-ST-FRE3 PDCSY-ST-FRE4 PDCSY-ST-FRE1-CAL
PDCSY-ST-FRE2-CAL PDCSY-ST-FRE3-CAL PDCSY-ST-FRE4-CAL PDCSY-ST-FRE1-IP65 PDCSY-ST-FRE2-IP65 PDCSY-ST-FRE3-IP65 PDCSY-ST-FRE4-IP65 PDCSY-ST-DFK PDCSY-BRK

Description
Capillary Frost Thermostats - Auto reset, 6 m capillary Capillary Frost Thermostats - Manual reset, 6 m capillary Capillary Frost Thermostats - Auto reset, 2 m capillary Capillary Frost Thermostats - Manual reset, 2 m capillary

Auto reset, 6m capillary pre-set to 6C* Manual reset, 6m capillary pre-set to 6C* Auto reset, 2m capillary pre-set to 6C* Manual reset, 2m capillary pre-set to 6C* Auto reset, 6m capillary, Frost Thermostat Manual reset, 6m capillary, Frost Thermostat Auto reset, 2m capillary, Frost Thermostat Manual reset, 2m capillary, Frost Thermostat Accessories Pack of six additional capillary fixing clips Mounting bracket for PDCSY-ST-FREx

Data sheet PDCSY-ST-FRE.pdf

Tel: +33 (0) 4 78 45 01 23 Fax: +33 (0) 4 78 45 22 33 web: www.distech-controls.eu

37

Peripheral Programme

PDCSY-ST-TY

Space Thermostats

PDCSY-TT-325

Duct Averaging Sensors

The PDCSY-ST-TY series of wall mounting Space Thermostats are suitable for heating and/or cooling and frost protection applications. FEATURES Tamperproof option Bi-metallic switch mechanism for reliability COMMON SPECIFICATION Operating voltage 220/240 VAC @ 50/60 Hz Switching differential <1K Switching current 250 VAC 10 (2) A SPDT; 3 (1) A SPST Sensor system Bi-metal Housing material ABS V0 Ambient range 50C max. Protection IP20 Dimensions PDCSY-ST-TY92C3T 78 x 78 x 36 mm max. Others 82 x 82 x 32 mm max. Weight PDCSY-ST-TY92C3T 120 g Others 220 g HEATING STAT SPECIFICATION PDCSY-ST-TY92C1 Contact configuration SPST open-on-rise Temperature range 5 to 35C FROST STAT SPECIFICATION PDCSY-ST-TY92C1F Contact configuration SPST open-on-rise Temperature range 5 to +15C Switching current 250 VAC @ 10 (2) A HEATING OR COOLING STAT SPECIFICATION PDCSY-ST-TY92C3T & PDCSY-ST-TY92C3 Contact configuration SPDT Temperature range 5 to 35C Switching current 250 VAC @ 3 (1) A Part code PDCSY-ST-TY92C1 PDCSY-ST-TY92C3 Description Space Thermostat - Heating, 5 to 35C Space Thermostat - Heating or Cooling, 5 to 35C

The PDCSY-TT-325 Temperature Sensors are used for measuring temperature in ducts where an average reading across the air flow is required. Units contain either high quality thermistor, nickel or platinum sensing elements which are housed in a Nylon 12 tube, spaced at 0.5m (1.64 ft) intervals along the standard 2.2m (7.22 ft) length. SPECIFICATION Output types: Probe: Housing: Ambient range: Protection: Weight: Part code PDCSY-TT-325-A PDCSY-TT-325-CVO Thermistor Resistive Current 4 to 20mA Voltage 0 to 10Vdc Material Nylon 12 Dimensions 2.2m x 8mm dia. (7.22 ft x 0.31) Material ABS (flame retardant) Dimensions 74 x 70 x 50mm (2.91 x 2.76 x 1.97) 10 to +90C (14 to 194F) IP65 220g (0.49 lb) Description Passive Output Duct Averaging Sensor - 10K3A1 (TypeII) Active Output 4-20mA/0-10Vdc selectable output, Output ranges: 10 to +40C (14 to 104F) or 10 to +110C (14 to 230F) selectable Suffix (add to part code) -5m 5m (16.40 ft) probe length Data sheets PDCSY-TT-325.pdf, PDCSY-TT-CVO.pdf Note: Custom lengths available.

PDCSY-ST-TY92C1F Space Thermostat - Frost, -5 to +15C PDCSY-ST-TY92C3T Space Thermostat - Heating or Cooling, Tamper, 5 to 35C Data sheet PDCSY-ST-TY.pdf

PDCSY-TT-331

Outside Air Sensors

PDCSY-TT-322

Duct Sensors

The PDCSY-TT-331 range are direct output, Temperature Sensors for measuring outside air temperature. Units contain either a high quality thermistor, Nickel or Platinum sensing element. The sensors are housed in IP65 rated enclosures. The PDCSY-TT-331 has a cap containing the sensing element located externally in the shadow of the lid to curb the effects of solar gain, but should always be situated in a sheltered position on a north facing wall. SPECIFICATION Output types: Housing material: Dimensions: Ambient range: Protection: Weight: Part code PDCSY-TT-331-A Thermistor Resistive Current 4 to 20mA Voltage 0 to 10Vdc ABS (flame retardant) 74 x 70 x 50mm (2.91 x 2.76 x 1.97) 10 to +90C (14 to 194F) IP65 160g (0.35 lb) Description Passive Output Outside Air Sensors - 10K3A1 (TypeII) Active Output PDCSY-TT-331-CVO 4-20mA/0-10Vdc selectable output Output ranges: 10 to +40C (14 to 104F) or 10 to +110C (14 to 230F) selectable Data sheets PDCSY-TT-331.pdf, PDCSY-TT-CVO.pdf Note: Custom lengths available.

The PDCSY-TT-322 temperature sensor are used to measure air temperature in ducts. Units contain either a high quality thermistor, nickel or platinum sensing element. The sensing element is fitted into a stainless steel probe. A flange plate is available for adjustment of penetration depth (order as PDCSY-TT-DFP). SPECIFICATION Output types: Thermistor Resistive Current 4 to 20mA Voltage 0 to 10Vdc Probe: Material Stainless steel Dimensions 150mm (5.91) or 250mm (9.84) x 6mm (0.24) dia. Housing: Material ABS (flame retardant) Dimensions 74 x 70 x 50mm (2.91 x 2.76 x 1.97) Ambient range: 10 to +90C (14 to 194F) Protection: IP65 Weight: 160g (0.35 lb) Note: Custom lengths available. Part code PDCSY-TT-322-A PDCSY-TT-322-CVO Description Passive Output Duct Sensor - 10K3A1 (TypeII) Active Output 4-20mA/0-10Vdc selectable output, Output ranges: 10 to +40C (14 to 104F) or 10 to +110C (14 to 230F) (selectable) Suffix (add to part code) -250 PDCSY-TT-DFP 250mm probe length Accessory Duct flange plate Data sheets PDCSY-TT-322.pdf, PDCSY-TT-CVO.pdf

38

Innovative Solutions for Greener Buildings

PDCSY-TT-332 Outside Air Sensors with Radiation Shield


For measuring outside air temperature the PDCSYTT-332 contains either a high quality thermistor, nickel or platinum sensing element. The sensors are housed in IP65 rated enclosures. The PDCSY-TT-332 has the element fitted into a PTFE radiation shield, designed to provide fast response times to changes in outside air temperature and to protect the element from the effects of direct sunlight. SPECIFICATION Output types:Thermistor Housing material: Dimensions: Ambient range: Protection: Weight: Protection Weight Part code PDCSY-TT-332-A Resistive Current 4 to 20mA Voltage 0 to 10Vdc ABS (flame retardant) 74 x 70 x 50mm (2.91 x 2.76 x 1.97) 10 to +90C (14 to 194F) IP65 160g (0.35 lb) IP65 160 g Description Passive Output Outside Air Sensors with Radiation Shield - 10K3A1 (TypeII) Active Output PDCSY-TT-332-CVO 4-20mA/0-10Vdc selectable output, Output ranges: 10 to +40C (14 to 104F) or 10 to +110C (14 to 230F) selectable Data sheets PDCSY-TT-332.pdf, PDCSY-TT-CVO.pdf

PDCSY-TT-342

High Temperature Immersion Sensors

The PDCSY-TT-342 is for use in high temperature applications up to 400C (752F). The sensor consists of a stainless steel probe fitted to an aluminium head, and connected by a 1m (3.28 ft) cable to a plant housing where terminations and transmitters are located. The PDCSY-TT-342 is available in two standard probe lengths of 150mm (5.91) or 250mm (9.84), for direct mounting into the PDCSY-TT-PO521 or PDCSY-TT-POHP range of stainless steel pockets. SPECIFICATION Output types: RTD Resistive Current 4 to 20mA Voltage 0 to 10Vdc Housing material: ABS (flame retardant) Dimensions: 74 x 70 x 50mm (2.91 x 2.76 x 1.97) Probe: Material Stainless steel Dimensions 150mm (5.91) or 250mm (9.84) x 6mm dia. (0.24) Ambient range: Housing 10 to +90C (14 to 194F) Probe 10 to +400C (14 to 752F) Protection: IP65 Weight: 340g (0.75 lb) Part code PDCSY-TT-342-D PDCSY-TT-342-E PDCSY-TT-342-CVO Description Passive Output (150mm (5.91) Probe) PT100A Sensor PT1000A Sensor Active Output (150mm (5.91) Probe) 4-20mA/0-10Vdc selectable output Output ranges: 10 to +40C (14 to 104F), 10 to +110C (14 to 230F), 10 to +160C (14 to 320F) or 0 to 400C (32 to 752F) selectable Suffixes (add to part code) -250 PDCSY-TT-DFP 250mm (9.84) Accessory Duct flange plate Data sheets PDCSY-TT-342.pdf, PDCSY-TT-CVO.pdf

TT-341

Immersion Sensors PDCSY-TT-351

These Immersion Sensors are used for measuring the temperature of liquids in pipework. Units contain either a high quality thermistor, nickel or platinum element. The PDCSY-TT-341 sensing element is housed in a stainless steel probe fitted to an IP65 rated enclosure, for direct mounting into PDCSY-TT-PO521 or PDCSY-TT-PO-HP range of stainless steel pockets. SPECIFICATION Output types: Thermistor Resistive Current 4 to 20mA Voltage 0 to 10Vdc Housing material: ABS (flame retardant) Dimensions: 74 x 70 x 50mm (2.91 x 2.76 x 1.97) Probe: Material Stainless steel Dimensions 65mm (2.56), 150mm (5.91) or 250mm (9.84) x 6mm dia. (0.24) Ambient range: 10 to +90C (14 to 194F) Protection: IP65 Weight: 160g (0.35 lb) Part code PDCSY-TT-341-A PDCSY-TT-341-CVO Description Passive Output Immersion Sensors - 10K3A1 (TypeII) Active Output 4-20mA/0-10Vdc selectable output, Output ranges: 10 to +40C (14 to 104F) or 10 to +110C (14 to 230F) selectable Suffixes (add to part code) -65 -250 65mm (2.56) probe length 250mm (9.84) Data sheets PDCSY-TT-341.pdf, PDCSY-TT-CVO.pdf

Clamp-on Sensors

The PDCSY-TT-351 is used to measure pipe temperature, and contain either a high quality thermistor, nickel or platinum element, which is housed in a 50mm (1.97) long brass probe with two metres (6.56 ft) of PTFE 2-core cable as standard connecting the probe to an IP65 housing for termination. SPECIFICATION Output types: Housing material: Dimensions: Cable length: Ambient range: Protection: Weight: Part code PDCSY-TT-351-A PDCSY-TT-351-CVO Thermistor Resistive Current 4 to 20mA Voltage 0 to 10Vdc ABS (flame retardant) 74 x 70 x 50mm (2.91 x 2.76 x 1.97) 2 metre (6.56 ft) standard 10 to +90C (14 to 194F) IP65 200g (0.44 lb) Description Passive Output Clamp-on Sensors - 10K3A1 (TypeII) Active Output 4-20mA/0-10Vdc selectable output Output ranges: 10 to +40C (14 to 104F) or 10 to +110C (14 to 230F) (selectable) Suffixes (add to part code) -5M -R 5m (16.40 ft) cable length Brass lug potted for low temp. applications Data sheets PDCSY-TT-351.pdf, PDCSY-TT-CVO.pdf

Tel: +33 (0) 4 78 45 01 23 Fax: +33 (0) 4 78 45 22 33 web: www.distech-controls.eu

39

Peripheral Programme

PDCSY-TT-518

Thimble Sensors

PDCSY-TT-555

Flying Lead Sensors

These low cost, direct output, Thimble Temperature Sensors are used for measuring air temperature in indoor spaces. Units contain either a high quality thermistor, Nickel or Platinum sensing element. The sensing element is mounted in an attractive thimble enclosure for surface mounting, typically on a backplate or a ceiling tile. FEATURE Plastic, brass, stainless steel or aluminium thimble options SPECIFICATION Output types Thread Connections Ambient range Protection Dimensions Weight Part code PDCSY-TT-518-A -AL -SS -BR -BW -5M PDCSY-TT-518-CVO Thermistor Resistive Current 4 to 20 mA Voltage 0 to 10 VDC Plastic M16 x 1.5 x 25 mm All others M16 x 1.5 x 12 mm Internal 11 x 20 mm 2m flying lead, screened 10 to +60C IP30 Overall 45 x 22 mm dia. 80 g Description Thimble Sensor - 10K3A1 (TypeII) Suffixes (add to part code) Aluminium thimble Stainless steel thimble Brass thimble Brilliant white thimble 5 m cable length Active Output 4-20mA/0-10Vdc selectable output * Output ranges: 10 to +40C (14 to 104F) or 10 to +110C (14 to 230F) (selectable) Data sheets PDCSY-TT-518.pdf, PDCSY-TT-CVO.pdf Note: If no color is specified, standard off-white thimble will be supplied. * These units are supplied with the transmitter in the plant housing.

The PDCSY-TT-555 is a low cost, Direct Output Temperature Sensor used to measure air temperature, especially in fan-coil units etc., and contain either a high quality thermistor, nickel or platinum sensing element suitable for the range 10 to +60C. The sensing element is housed in a 25 mm long acetyl probe, with two metres of 2-core screened cable fitted as standard. Longer lengths can be made to order. Order option (-R) for a cap with the element potted in a waterproof compound. SPECIFICATION Output types Probe material Probe dimensions Ambient range Protection Weight Thermistor Resistive Current 4 to 20 mA Voltage 0 to 10 VDC Acetyl 25 x 6 mm dia. 10 to +60C IP65 80 g

Note: Custom lengths available. * These units are supplied with the transmitter in the plant housing. Part code PDCSY-TT-555-A PDCSY-TT-555-Z Description Flying Lead Sensor - 10K3A1, Type 2 Flying Lead Sensor - 10K NTC, RCL/RCB Series Data sheets PDCSY-TT-555.pdf

PDCSY-TT-PO

Immersion Sensor Pockets

PDCSY-TT-PO521 and TT-PO-HP range of Stainless Steel Pockets are for use with immersion sensors TT-341 and TT-342. The two part welded TT-PO521 pockets are intended for low flow applications. They may be used in applications such as sumps or storage tanks or low flowing water in pipes. For applications requiring installation in high flowing water, the TT-PO-HP should be used. Pockets are designed to accept either a 65mm (2.56), 150mm (5.91) or 250mm (9.84) x 6mm (0.24) dia. probes, which are locked in position by a grub screw. These pockets can be installed in any system that is constructed from compatible materials whose operating pressures and flow rates are within the specified ranges. SPECIFICATION Material: S/S 316 Temperature ranges: 20 to +400C (4 to +752F) Maximum pressure (out to in): 16 bar (232 psi) Water velocity max. (0 to100C): PDCSY-TT-PO521 3.7 m/s (728 ft/min) PDCSY-TT-PO521-65 18 m/s (3543 ft/min) PDCSY-TT-PO521-250 1.7 m/s (335 ft/min) PDCSY-TT-PO-HP 7.0 m/s (3340 ft/min) PDCSY-TT-521-HP-250 6.5 m/s (1280 ft/min) Weights: PDCSY-TT-PO521 40g (0.31 lb) PDCSY-TT-PO-HP 220g (0.49 lb) Note: Custom lengths available. Part code PDCSY-TT-PO521-65 PDCSY-TT-PO521 PDCSY-TT-PO-HP Description 65mm (2.56) Pockets Stainless Steel Immersion Pocket 150mm (5.91) Pockets Stainless Steel Immersion Pocket High Performance Stainless Steel Immersion Pocket 250mm (9.84) Pockets PDCSY-TT-PO521-250 PDCSY-TT-PO-HP-250 Stainless Steel Immersion Pocket High Performance Stainless Steel Immersion Pocket Data sheet PDCSY-TT-PO.pdf

PDCSY-TT-535

External Black Bulb Sensors

The PDCSY-TT-535 sensor is used for radiant heat in outdoor spaces. Black Bulb Temperature Sensors are used to calculate comfort temperature which is specified as the average of the conductive temperature and the radiant temperature. Units contain either a high quality thermistor, platinum or nickel sensing element. Sensor types compatible with most controls manufacturers equipment are available. TCOmfORt = T RADIANt + T CONDUCtIve 2 SPECIFICATION Output types Ambient range Material Dimensions Protection Weight Part code PDCSY-TT-535-A Thermistor Resistive Current 4 to 20 mA Voltage 0 to 10 VDC 10 to +60C Housing ABS (flame retardant) Black bulb Anodised aluminium Housing 55 x 90 mm dia. Black bulb 17.5 x 37 mm dia. IP65 160 g Description External Black Bulb Sensor IP65 10K3A1, Trend, Seachange Active Output PDCSY-TT-535-CVO 4-20mA/0-10Vdc selectable output Output ranges: 10 to +40C (14 to 104F) or 10 to +110C (14 to 230F) selectable Data sheets PDCSY-TT-535.pdf, PDCSY-TT-CVO.pdf

40

Innovative Solutions for Greener Buildings

PDCSY-TT-626

True Duct Averaging Sensors

PDCSY-UI-AA

Alarm Annunciators

The True Duct Averaging Sensor contains a PT100B element, which measures at every instantaneous point along the full length of the copper tube. SPECIFICATION Output types: PT100B Resistive Current 4 to 20mA Voltage 0 to 10Vdc Probe: Material Copper Dimensions 2050mm (6.73 ft) (includes 50mm (1.97) collar) x dia. Housing: Material ABS (flame retardant) Dimensions 116 x 106 x 52mm (4.57 x 4.17 x 2.05) Ambient range: 10 to +90C (14 to 194F) Protection: IP65 Weight: 420g (0.93 lb) Part code PDCSY-TT-626-PT100B PDCSY-TT-626-CVO Description Passive Output PT100B Thermistor Output Active Output 4-20mA/0-10Vdc selectable output Output ranges: 10 to +40C (14 to 104F) or 10 to +110C (14 to 230F) (selectable) Data sheets PDCSY-TT-626.pdf, PDCSY-TT-CVO.pdf

The PDCSY-UI-AA series are used in conjunction with one or two analogue or VFC signals to provide low cost local audible and visual alarm facilities. The units can accept voltage, current and VFC switched inputs. Adjustment of alarm threshold and the time delay before an alarm is standard on all models. A mute button silences the audible alarm, whilst the visual alarm will not reset until the monitored parameter returns to within its desired range. FEATURES 1 or 2-channels LEDs for OK/alarm indication Audible alarm mute button Alarm output relay SPECIFICATION Input signals Alarm delay time Relay output Buzzer output LED indication Power supply Housing PDCSY-UI-AA1-F 0-10 VDC, 4-20 mA, relay or 24 VAC PDCSY-UI-AA2-F 0-10 VDC, 4-20 mA or relay 5 to 45 secs SPCO, 6 A @ 240 VAC 85 dB @ 1 m Green = OK, flashing red = alarm 24 VAC/DC 15% PDCSY-UI-AA1-F Panel mounting or UK standard single gang box PDCSY-UI-AA2-F For panel mounting only or deep UK standard double gang box Ambient range 10 to +40C Protection IP32 Dimensions PDCSY-UI-AA1-F 85 x 85 x 37 mm PDCSY-UI-AA2-F 145 x 85 x 35 mm Weight PDCSY-UI-AA1-F 140 g PDCSY-UI-AA2-F 200 g Description Alarm Anunciator - 1-channel Interface Panel Alarm Anunciator - 2-channels Interface Panel Data sheets PDCSY-UI-AA1-F.pdf, PDCSY-UI-AA2-F.pdf

Part code PDCSY-UI-AA1-F PDCSY-UI-AA2-F

PDCSY-TT-915

Black Bulb Sensors

Comfort temperature measurement can be best achieved by taking into account the radiant effect of surfaces within the controlled space. The comfort temperature is specified as the average of the conductive temperature and the radiant temperature. T comfort = T radiant + T conductive 2 The PDCSY-TT-915 is a low cost Black Bulb Temperature Sensor used to measure radiant heat in indoor spaces. Units contain either a high quality thermistor or Platinum element. SPECIFICATION Output types: Ambient range: Protection: Material: Black bulb: Dimensions: Weight: Part code PDCSY-TT-915-A PDCSY-TT-915-CVO Thermistor Resistive Current 4 to 20mA Voltage 0 to 10Vdc 10 to +60C (14 to 140F) IP30 Housing ABS (flame retardant) Anodised aluminium Housing 85 x 85 x 23mm (3.35 x 3.35 x 0.91) Bulb 17.5 x 37mm (0.69 x 1.46) dia. 120g (0.26 lb) Description Passive Output Black Bulb Sensors - 10K3A1 Active Output 4-20mA/0-10Vdc selectable output Output ranges: 10 to +40C (14 to 104F) or 10 to +110C (14 to 230F) selectable Interface Options -SP 2-wire 1-11k setpoint Data sheets PDCSY-TT-915.pdf, PDCSY-TT-CVO.pdf

Tel: +33 (0) 4 78 45 01 23 Fax: +33 (0) 4 78 45 22 33 web: www.distech-controls.eu

41

Peripheral Programme

PDCSY-WD-X

Water Leak Detection Cable

PDCSY-WD-CPS

Condensation Detector

The PDCSY-WD-x range is designed to detect water leaks either at localised points using the PDCSY-WD-PS point sensor or larger areas with the PDCSYWD-CS cable sensor, a rain sensor is also available. All these sensors are used with the PDCSY-WD-AMX range of modules that are suitable for DIN-rail mounting inside AHUs, power distribution units or general areas where leak detection is required. They are fitted as standard with LED indication of the water leak status, and sounder that can be disabled by simply removing a jumper. The PDCSY-WDAMX relay output can either configured to be manual or auto reset. FEATURES - Modules AC detector excitation for reliability 24Vac/dc or 230Vac versions Audible alarm FEATURES - Sensors WD-CS is easy to lay and detects along its entire length More than on WD-PS can be connected to a WD-AMX Self-contained heater to avoid nuisance alarms on WD-RS SPECIFICATION Power Supply: Supply Current (WD-AMX): Output: Audible alarm: Maximum cable run: Ambient range: Dimensions: 1.22) Protection: Weights: PDCSY-WD-AMX-1 PDCSY-WD-AMX-2 PDCSY-WD-RS heater 50mA max. 24Vac/dc 10% 230Vac @ 50Hz 24Vac/dc

The condensation prevention sensor has been designed to provide a switched output signal to prevent the onset of condensation on chilled surfaces such as chilled beams. The detector measures the temperature compensated RH and surface temperature of the chilled surface and calculates the dew point temperature. This is compared to an adjustable setpoint to provide either a current output or VFC switched output. FEATURES Reliable and accurate switching VFC or current output Quick and simple to install SPECIFICATION Output: Supply voltage: Cable: Dimensions: Weight: Part code PDCSY-WD-CPS PDCSY-WD-CPS-5M Current mode (dry <3mA, wet >12 mA) VFC mode SPDT contact, 240Vac @ 1A resistive 24Vdc 5% or 24Vac 10% Low smoke and fume 70 x 48 x 30mm (2.76 x 1.89 x 1.18) 80g (0.18 lb) Description Condensation Detector - 2m (6.56 ft) lead Condensation Detector - 5m (16.4 ft) lead Datasheet PDCSY-WD-CPS.pdf

PDCBP-NV2

2 Way terminal valves

SPDT relay 12A @ 230Vac 85dB @ 2.3kHz at 10cm 200m (656ft) including detection cable Temperature 0 to 40C (32 to 104F) RH 0 to 80% RH, non-condensing PDCSY-WD-AMX 72 x 64 x 55mm (2.83 x 2.52 x 2.17) PDCSY-WD-PS 58 x 58 x 31mm (2.28 x 2.28 x PDCSY-WD-RS PDCSY-WD-AMX PDCSY-WD-RS PDCSY-WD-AMX-1 PDCSY-WD-AMX-2 PDCSY-WD-CS PDCSY-WD-PS PDCSY-WD-RS 70 x 30 x 45mm (2.76 x 1.18 x 1.77) IP30 IP65 100g (0.22lb) 240g (0.53lb) 520g (1.15lb) max. 100g (0.22lb) 125g (0.28lb)

PDCBP-NV2 type terminal valves are used for zonal or individual regulation in HVAC hort or cold water systems in a temperaure range from 2 to 120C. PDCBP-NV2 valves are used to control terminal units such as fan coils, heaters, cold ceiling... FEATURES Nickel-plated brass body KVS fixed or adjustable Flat end or threaded fitting PN16 From +2 to 120C Normally open valve SPECIFICATION Nominal pressure PN16 Fluid Water Fluid temperature 2 to 120C Pipe connection Rp 1/2 Materials Nickel-plated brass body Brass adapter Stainless steel AISI 303 Axis Stainless steel AISI 303 Spring Stainless steel AISI 303 Washer Joint O-ring EPDM Weight D10 207 g D15 243 g D20 361 g
Part code PDCBP-NVP2D15 PDCBP-NVP2D15V PDCBP-NVP2D15F PDCBP-NV2D10 PDCBP-NV2D10V PDCBP-NV2D10F PDCBP-NV2D15 PDCBP-NV2D15V PDCBP-NV2D15F PDCBP-NV2D20 PDCBP-NV2D20V PDCBP-NV2D20F Description Brass 2 Way Valve, flat scope, PN16, 1/2", Kvs 1,2 (fixed) Brass 2 Way Valve, flat scope, PN16, G1/2", Kvs adjustable 0.10 to 0.81 Brass 2 Way Valve, flat scope, PN16, G1/2", Kvs adjustable 0.05 to 0.36 Brass 2 way valve with thread, PN16, G3/8", Kvs 1.2 (fixed) Brass 2 way valve with thread, PN16, G3/8", Kvs adjustable 0.10 to 0.81 Brass 2 way valve with thread, PN16, G3/8", Kvs adjustable 0.05 to 0.36 Brass 2 way valve with thread, PN16, G1/2", Kvs 1.2 (fixed) Brass 2 way valve with thread, PN16, G1/2", Kvs adjustable 0.10 to 0.81 Brass 2 way valve with thread, PN16, G1/2", Kvs adjustable 0.05 to 0.36 Brass 2 way valve with thread, PN16, G3/4", Kvs 1.5 (fixed) Brass 2 way valve with thread, PN16, G3/4", Kvs adjustable 0.10 to 0.81 Brass 2 way valve with thread, PN16, G3/4", Kvs adjustable 0.05 to 0.36

Note: Custom PDCSY-WD-CS lengths are available on request. Part code PDCSY-WD-AMX-1 PDCSY-WD-AMX-2 PDCSY-WD-CS-2M PDCSY-WD-CS-5M PDCSY-WD-CS-10M PDCSY-WD-CS-15M PDCSY-WD-CS-20M PDCSY-WD-CS-25M PDCSY-WD-PS PDCSY-WD-RS PDCSY-WD-RS-5M PDCSY-WD-FC Description Modules 24Vac/dc Controller with buzzer 230Vac Controller with buzzer Sensors Water Cable Sensor - 2m (6.56ft) cable, 3m (9.84ft) leader Water Cable Sensor - 5m (16.4ft) cable, 3m (9.84ft) leader Water Cable Sensor - 10m (32.81ft) cable, 3m (9.84ft) leader Water Cable Sensor - 15m (49.21ft) cable, 3m (9.84ft) leader Water Cable Sensor 20m (65.62ft) cable, 3m (9.84ft) leader Water Cable Sensor 25m (82.02ft) cable, 3m (9.84ft) leader Water Point Sensor, 2m (6.56ft) Rain Sensor with internal heater, 2m (6.56ft) leader Rain Sensor with internal heater, 5m (16.4ft) leader Accessory Pack of 20 fixing clips Data sheets PDCSY-WD-AMX.pdf, PDCSY-WD-CS.pdf, PDCSY-WD-PS.pdf, PDCSY-WD-RS.pdf

42

Innovative Solutions for Greener Buildings

PDCBP-NV4

4 Way terminal valves

PDCSY-VT-xP

Terminal Unit Valves

PDCBP-NV4 regulation valves are used for terminal regulation in hot or cold water systems and present a temperature range from +2C to +100C for a 16 bars nominal pressure (PN16). These terminal valves are typically used as dividing valves to control zones and terminal units such as fan coils, VAV boxes, cold ceilings... The adjustment way of the valve body is normally open (NO). When pushing the valve axis, the transit way is closed and the by-pass way is open. the integrated spring drives back the valve in its normally open position. The Kvs value of the by-pass can be reduced down to 70% from the Kvs value of the transit way. Thanks to this reduction, the friction loss of the consumer is taken into account, allowing for a proper modulating regulation. FEATURES Brass body PN16 DN15 or DN20 Fluid : water, +2C .. +100C Fixed Kvs value ISO 228/1 Flat ends

The PDCSY-VT-xP new range of terminal unit valves are designed to provide a high quality long lasting solution for control of hot or chilled water applications with up to a 50% glycol mix. They are suitable for fan coil units, small re-heaters and re-coolers in temperature control systems. They have replaceable interchangeable cartridges that can be changed without removing the valve from the line. FEATURES Suitable for water or glycolic water Better than 50:1 turndown ratio Soft sealing on plug gives complete shut-off SPECIFICATION Nominal pressure PN25 Connections 2, 3-port For 1/2 BSP or 3/4 BSP (not included) 4-port Compression Stroke length 2-port valves 4 mm 3-port valves 2.8 mm 4-port valves up to 2.60 Kvs 2.8 mm 4-port valve 3.00 Kvs 4 mm Medium temp 0 to 120C Glycol 50% max. Materials Body Low zinc bronze, alloy C84400 Stem Stainless steel Packing Double EPDM Disc / plunger EPDM / brass Leakage 100% tight shut-off Turndown ratio 50:1 Max. pressure 3.5 bar Weight 650 g max. Part code Description 2-way valves PDCSY-VT-2P-15-01 PDCSY-VT-2P-15-02 PDCSY-VT-2P-15-03 PDCSY-VT-2P-15-04 PDCSY-VT-2P-15-05 PDCSY-VT-2P-15-06 PDCSY-VT-2P-20-07 PDCSY-VT-2P-20-08 Part code PDCSY-VT-3P-15-01 PDCSY-VT-3P-15-02 PDCSY-VT-3P-15-03 PDCSY-VT-3P-15-04 PDCSY-VT-3P-20-05 PDCSY-VT-4P-15-01 PDCSY-VT-4P-15-02 PDCSY-VT-4P-15-03 PDCSY-VT-4P-15-04 15mm, 0.43 Kvs, Equal percentage 15mm, 0.86 Kvs, Equal percentage 15mm, 1.30 Kvs, Equal percentage 15mm, 1.72 Kvs, Equal percentage 15mm, 2.15 Kvs, Equal percentage 15mm, 2.58 Kvs, Equal percentage 20mm, 2.58 Kvs, Equal percentage 20mm, 3.87 Kvs, Linear Description 3-way valves (diverting only) 15mm, 0.43 Kvs, Equal percentage 15mm, 0.86 Kvs, Equal percentage 15mm, 1.72 Kvs, Equal percentage 15mm, 2.58 Kvs, Equal percentage 20mm, 3.10 Kvs, Linear 4-way valves (diverting only) 15mm, 0.86 Kvs, Linear 15mm, 1.70 Kvs, Linear 15mm, 2.60 Kvs, Linear 15mm, 3.00 Kvs, Linear Datasheet PDCSY-VT-xP.pdf

SPECIFICATION Nominal pressure PN16 Fluid Water Fluid temperature From 2 to 120C Function Diverting valve Connection ISO 228/1 Material CW617N Brass body CW617N Brass adapter Stainless steel axis Stainless steel spring AISI 303 Stainless steel washer Joint O-ring EPDM Dimensions D15 : 52 x 26 x 40 mm D20 : 52 x 26 x 50 mm Part code Description PDCBP-NV4D Brass 4 Way Valve, flat scope, PN16, G1/2", Kvs 1.6 PDCBP-NV4D Brass 4 Way Valve, flat scope, PN16, G1/2", Kvs 1.0 PDCBP-NV4D Brass 4 Way Valve, flat scope, PN16, G1/2", Kvs 0.63 PDCBP-NV4D Brass 4 Way Valve, flat scope, PN16, G1/2", Kvs 0.4 PDCBP-NV4D Brass 4 Way Valve, flat scope, PN16, G3/4", Kvs 0.26

PDCBP-A2004

230 VaC Actuator

A2004 Actuators are designed to control remotely terminal regulation valves in HVAC applications (hot and cold systems, zonal and individual regulation...) FEATURES No maintenance Compact conception Universal valve adapter 360position indicator Silent operation Minimum consumption Water-protected SPECIFICATIONS Supply voltage Operating current Starting current Consumption Actuation force Course Protection Conpliance Connection Temperature Weight 230 VAC 10% 50/ 60 Hz 8 mA 300 mA during 200 ms 1.8 W 100 N 5% 4 mm IP54 EN60730 2 x 0.75 mm PVC 1 m cable Storage -25 to +60C Ambient 0 to +60C Fluid 0 to +100C 100 g
Description Thermic actuators 230 VAC, cable 2m, with Distech logo Valve adapter VA10 type for a 4 way valve NV4D type Valve adapter VA80 type for a 2 way valve NV4D type

PDCSY-VT-24

Terminal Unit Valve Actuators

The PDCSY-VT-24 range of actuators are for use with the PDCSY-VT-xP terminal unit valves. They have end of travel automatic shut-off for long life expectancy. On start-up the modulating version has an automatic calibration sequence during which the two ends of travel are programmed. The reversible, brushless, synchronous, electric motor maintains accurate positioning and provides creep-free control with extreme accuracy. FEATURES Raise/lower (3-point) or modulating control types No tools required for mounting Hand override Life expectancy in excess of million cycles Quite operation

Part code PDCBP-BA2004.00.02.DISTECH PDCBP-VA10 PDCBP-VA80

Tel: +33 (0) 4 78 45 01 23 Fax: +33 (0) 4 78 45 22 33 web: www.distech-controls.eu

43

Peripheral Programme
SPECIFICATION 24Vac +10% 5% 45mA, 1VA PDCSY-VT-24-RL Raise/lower (3-point) PDCSY-VT-24-M 0-10Vdc Modulating 50/60Hz 4.5mm (0.18) PDCSY-VT-24-RL 90 seconds @ 60Hz PDCSY-VT-24-RL 108 seconds @ 50Hz PDCSY-VT-24-M 120 seconds 1-5Vdc (VT-24-M only) Temperature 5 to 50C (41 to 122F) Humidity 0 to 95% non-condensing IP51 240g (0.53 lb) Description 24V Raise/Lower Actuator 24V Modulating Datasheet PDCSY-VT-24.pdf Nominal pressure Fluid temperature Pipe connection Material Weight
Part code PDCSA-BUN015F330 PDCSA-BUN015F320 PDCSA-BUN015F310 PDCSA-BUN015F300 PDCSA-BUN020F300 PDCSA-BUN015F300 PDCSA-BUN032F300 PDCSA-BUN040F300 PDCSA-BUN050F300 PDCSA-BUN050F200 PDCSA-361951015 PDCSA-361951020 PDCSA-361951025 PDCSA-361951032 PDCSA-361951040 PDCSA-361951050

SPECIFICATION Power supply: Power consumption: Control type: Frequency: Stroke: Speed: Feedback: Ambient: Protection: Weight: Part code PDCSY-VT-24-RL PDCSY-VT-24-M

PN16 -15 to 150C Rp 1/2 DZR (Dezincification Resistant) cast brass body DZR cast brass seat Stainless steel spindle DZR brass glass-fibre reinforced Teflon sealing ring Stuffing box made of DZR brass with wiper ring and double O-ring seal in EPDM DN15 : 820 g DN20 : 1 kg DN25 : 1.30 kg DN32 : 1.74 kg DN40 : 2.52 kg DN50 : 3.44 kg
Description 3-way valve with male thread PN16 DN15 Kvs 1=% 3-way valve with male thread PN16 DN15 Kvs 1.6 =% 3-way valve with male thread PN16 DN15 Kvs 2.5=% 3-way valve with male thread PN16 DN15 Kvs 4.0=% 3-way valve with male thread PN16 DN20 Kvs 6.3 =% 3-way valve with male thread PN16 DN25 Kvs 10 =% 3-way valve with male thread PN16 DN32 Kvs 16 =% 3-way valve with male thread PN16 DN40 Kvs 22 =% 3-way valve with male thread PN16 DN50 Kvs 28 =% 3-way valve with male thread PN16 DN50 Kvs 40 linear Accessories Screw fitting for male thread with flat seal DN15 Screw fitting for male thread with flat seal DN20 Screw fitting for male thread with flat seal DN25 Screw fitting for male thread with flat seal DN32 Screw fitting for male thread with flat seal DN40 Screw fitting for male thread with flat seal DN50

PDCSY-VT-SR

Spring Return Terminal Unit Valve Actuators

These spring return actuators are designed for on/ off control and are used with the 2 or 3-port VT-xP terminal unit valves. The PDCSY-VT-SR-xx-1 normally open series and the PDCSY-VT-SR-xx-2 normally closed series are 2-position, 2-wire fail safe on power disruption actuators. FEATURES 24Vac and 230Vac supply options Normally closed and normally open versions Position indicator Maintenance free

PDCSA-VUN

2 Way Valve VUN

SPECIFICATION Power supply: Power consumption: Control type: Stroke: Speed: Ambient: Protection: Weight: Part code PDCSY-VT-SR-24-1 PDCSY-VT-SR-24-2 PDCSY-VT-SR-230-1 PDCSY-VT-SR-230-2 PDCSY-VT-ST-24-x 24Vac 10% PDCSY-VT-ST-230-x 230Vac 10% 8VA, 0.3A @ 24Vac On/off 4.5mm (0.18) PDCSY-VT-SR-xx-1 20 sec. closing, 10 sec. opening PDCSY-T-SR-xx-2 20 sec. opening.10 sec. closing Temperature 5 to 50C (41 to 122F) Humidity 0 to 95% non-condensing IP20 360g (0.79 lb) Description 24V On/Off Spring Return N/O Actuator 24V On/Off Spring Return N/C Actuator 230V On/Off Spring Return N/O Actuator 230V On/Off Spring Return N/C Actuator Datasheet PDCSY-VT-SR.pdf

These control valves are characterised by being extremely reliable and accurate, and make a considerable contribution to providing environmentally friendly control. They comply with the most demanding requirements such as a quick-closing function, handling differential pressures, controlling media temperatures and providing a shut-off facility all with a low-noise design. The valve can be controlled to any intermediate position using an electric drive. The valve is closed when the valve stem is extended. FEATURES Nominal pressure 16 bar Nominal diameter DN15 to DN50 Control valve, contains no silicone grease Equal percentage characteristic, adjustable with SUT actuators to linear or quadratic If the spindle is retracted, the valve is closed Closing procedure against or with pressure SPECIFICATION

PDCSA-BUN

3 Way Valve BUN

These control valves are characterised by being extremely reliable and accurate, and make a considerable contribution to providing environmentally friendly control. They comply with the most demanding requirements such as having a rapid closing function, handling differential pressures, controlling media temperatures and providing a shut-off facility all with a low-noise design. The valve can be controlled to any intermediate position using an electric drive. The valve is closed with the valve stem extended. FEATURES Nominal pressure 16 bar Nominal diameter DN15 to DN50 Control valve, contains no silicone grease Equal percentage characteristic, adjustable with SUT actuators to linear or quadratic Linear mixing passage characteristic If the spindle is retracted, the valve is closed Can be used as mixing valve or diverting valve

Nominal pressure PN16 Fluid Water Fluid temperature -15 to 150C Characteristics F200 : linear F3xx : exponential Materials DZR (Dezincification Resistant) cast brass body DZR cast brass seat Stainless steel spindle DZR brass glass-fibre reinforced Teflon sealing ring Stuffing box made of DZR brass with wiper ring and double O-ring seal in EPDM Weight DN15 : 820 g DN20 : 1 kg DN25 : 1.30 kg DN32 : 1.74 kg DN40 : 2.52 kg DN50 : 3.44 kg

44

Innovative Solutions for Greener Buildings

Part code PDCSA-VUN015F350 PDCSA-VUN015F340 PDCSA-VUN015F330 PDCSA-VUN015F320 PDCSA-VUN015F310 PDCSA-VUN015F300 PDCSA-VUN020F300 PDCSA-VUN025F300 PDCSA-VUN032F300 PDCSA-VUN040F300 PDCSA-VUN050F300 PDCSA-VUN050F200 PDCSA-361951015 PDCSA-361951020 PDCSA-361951025 PDCSA-361951032 PDCSA-361951040 PDCSA-361951050

Description 2-way valve with male thread PN16 DN15 Kvs 0.4 =% 2-way valve with male thread PN16 DN15 Kvs 0.63 =% 2-way valve with male thread PN16 DN15 Kvs 1 =% 2-way valve with male thread PN16 DN15 Kvs 1.6 =% 2-way valve with male thread PN16 DN15 Kvs 2.5 =% 2-way valve with male thread PN16 DN15 Kvs 4 =% 2-way valve with male thread PN16 DN20 Kvs 6.3 =% 2-way valve with male thread PN16 DN25 Kvs 10 =% 2-way valve with male thread PN16 DN32 Kvs 16 =% 2-way valve with male thread PN16 DN40 Kvs 22 =% 2-way valve with male thread PN16 DN50 Kvs 28 =% 2-way valve with male thread PN16 DN50 Kvs 40, linear Accessories Screw fitting for male thread with flat seal DN15 Screw fitting for male thread with flat seal DN20 Screw fitting for male thread with flat seal DN25 Screw fitting for male thread with flat seal DN32 Screw fitting for male thread with flat seal DN40 Screw fitting for male thread with flat seal DN50

Part code PDCSA-BUE065F300 PDCSA-BUE065F200 PDCSA-BUE080F300 PDCSA-BUE080F200 PDCSA-BUE100F300 PDCSA-BUE100F200 PDCSA-BUE125F300 PDCSA-BUE125F200 PDCSA-BUE150F300 PDCSA-BUE150F200

Description 3 Way Valve Flanged,PN10/16,DN65,course=20mm,KVS=50 3 Way Valve Flanged,PN10/16,DN65,course=20mm,KVS=63 3 Way Valve Flanged,PN10/16,DN80,course=20mm,KVS=80 3 Way Valve Flanged,PN10/16,DN80,course=20mm,KVS=100 3 Way Valve Flanged,PN10/16,DN100,course=40mm,KS=125 3 Way Valve Flanged,PN10/16,DN100,course=40mm,KVS=160 3 Way Valve Flanged,PN10/16,DN125,course=40mm,KVS=200 3 Way Valve Flanged,PN10/16,DN125,course=40mm,KVS=240 3 Way Valve Flanged,PN10/16,DN150,course=40mm,KVS=300 3 Way Valve Flanged,PN10/16,DN150,course=40mm,KVS=320

PDCSA-VUE

2 Way Flanged Valve VUE

PDCSA-BUE

3 Way Flanged Valve BUE

The key features of these control valves are their high reliability and precision, and they make a major contribution towards environment-friendly control. They meet demanding requirements including quickclose functions, coping with differential pressures, controlling the medium temperature and providing a shut-off function - and all this is achieved with a low noise level. An automatic and fixed connection is made between the valve stem and the drive shaft. The cone (which is made of brass) controls an equal-percentage flow in the control passage. To compensate for the complementary characteristic of the consumer and to guarantee an identical quantity of medium regardless of the valve position, the mixing passage acts with a linear characteristic. The tightness of this valve is guaranteed by the seat which is machined in the body. The stuffing box is maintenance-free; it consists of a brass body, 2 O-rings, a wiper ring and the grease reserve. This is free of silicone grease and no silicone oil must be used for the stem. FEATURES Nominal pressure 16 bar Control valve, contains no silicone grease; painted black Nominal diameters DN15 to DN150 Equal percentage characteristic in the case of F300, adjustable with SUT actuators to linear or quadratic Linear characteristic in the case of F200 from DN50 with increased kvs value, adjustable with SUT actuators to equal percentage or quadratic Linear mixing passage characteristic With the spindle retracted, the valve is closed Can be used as control valve or diverting valve SPECIFICATION Nominal pressure Fluid temperature Characteristics Material Weight PN16 / PN10 -10 to 150C F200 : linear F300 : exponential Grey cast iron body Grey cast iron seat Stainless steel spindle Nominal diameter DN15 to DN50 cones in brass with glass-fibre reinforced Teflon sealing ring Cone nominal diameter DN65 to DN150 in brass, metal-to-metal seal Stuffing box made of brass with wiper ring and double O-ring seal in EPDM DN65 : 17.3 kg DN80 : 22.9 kg DN100 : 33.0 kg DN125 : 48.0 kg DN150 : 68.0 kg

The key features of these control valves are their high reliability and precision, and they make a major contribution towards environment-friendly control. They meet demanding requirements including quickclose functions, coping with differential pressures, controlling the medium temperature and providing a shut-off function - and all this is achieved with a low noise level. An automatic and fixed connection is made between the valve stem and the drive shaft. The cone (which is made of brass) controls an equal-percentage flow in the control passage. To compensate for the complementary characteristic of the consumer and to guarantee an identical quantity of medium regardless of the valve position, the mixing passage acts with a linear characteristic. The tightness of this valve is guaranteed by the seat which is machined in the body. The stuffing box is maintenance-free; it consists of a brass body, 2 O-rings, a wiper ring and the grease reserve. This is free of silicone grease and no silicone oil must be used for the stem. FEATURES Nominal pressure 16 bar Control valve, contains no silicone grease; painted black Nominal diameters DN15 to DN150 Equal percentage characteristic in the case of F300, adjustable with SUT actuators to linear or quadratic Linear characteristic in the case of F200 from DN50 with increased kvs value, adjustable with SUT actuators to equal percentage or quadratic With the spindle retracted, the valve is closed Closing procedure against pressure DN15 to DN150 or with the pressure DN15 to DN50 SPECIFICATION Nominal pressure Fluid temperature Characteristics Material Weight
Part code PDCSA-VUE050F300 PDCSA-VUE050F200 PDCSA-VUE065F300 PDCSA-VUE080F200 PDCSA-VUE080F300 PDCSA-VUE100F200 PDCSA-VUE100F300 PDCSA-VUE125F200 PDCSA-VUE125F300 PDCSA-VUE150F200 PDCSA-VUE150F300

PN16 / PN10 -10 to 150C F200 : linear F300 : exponential Grey cast iron body Grey cast iron seat Stainless steel spindle Nominal diameter DN15 to DN50 cones in brass with glass-fibre reinforced Teflon sealing ring Cone nominal diameter DN65 to DN150 in brass, metal-to-metal seal Stuffing box made of brass with wiper ring and double O-ring seal in EPDM DN50 : 11.2 kg DN65 : 17.3 kg DN80 : 22.9 kg DN100 : 33 kg DN125 : 48 kg DN150 : 68.0 kg
Description
2 Way Flanged Valve,, PN 16/10 DN50,stroke=8mm,Kvs= 28 2 Way Flanged Valve,, PN 16/10 DN50,stroke=8mm,Kvs= 40 2 Way Flanged Valve,, PN 16/10 DN65,stroke=20mm, Kvs= 49 2 Way Flanged Valve,, PN 16/10 DN80,stroke=20mm,Kvs= 100 2 Way Flanged Valve,, PN 16/10 DN80,stroke=20mm, Kvs=78 2 Way Flanged Valve,, PN 16/10 DN100,stroke=40mm, Kvs= 160 2 Way Flanged Valve,, PN 16/10 DN100,stroke=40mm, Kvs= 124 2 Way Flanged Valve,, PN 16/10 DN125,stroke=40mm, Kvs=240 2 Way Flanged Valve,, PN 16/10 DN125,stroke=40mm, Kvs= 200 2 Way Flanged Valve,, PN 16/10 DN150,stroke=40mm, Kvs= 320 2 Way Flanged Valve,, PN 16/10 DN150,stroke=40mm, Kvs= 300

Tel: +33 (0) 4 78 45 01 23 Fax: +33 (0) 4 78 45 22 33 web: www.distech-controls.eu

45

Peripheral Programme

PDCSY-VS-GCR

Manual Reset Gas Valves

PDCSY-VS-GCA

Automatic Reset Gas Valve

A range of Normally Closed Gas Valves, which shut off in the event of power failure. Typically used for emergency shut-off applications, upon power failure the valve will close until power has been restored and the manual reset mechanism has been activated. FEATURES Spring shut off action Manual reset upon restart SPECIFICATION Power supply 230 VAC and 24 VAC options Voltage tolerance 15 to +10% Pressure drop Natural gas flow with pressure drop of: 0.5 mbar or 1 mbar 1/2 screw 5 m3/h 7 m3/h 3 3/4 screw 6.5 m /h 8.7 m3/h 1 screw 8.7 m3/h 11 m3/h 11/4 screw 16 m3/h 23 m3/h 11/2 screw 20 m3/h 27 m3/h 2 screw 27 m3/h 38 m3/h 65mm flanged 54 m3/h 80 m3/h 80mm flanged 54 m3/h 80 m3/h 100mm flanged 93 m3/h 140 m3/h 125mm flanged 180 m3/h 260 m3/h 150mm flanged 180 m3/h 260 m3/h 200mm flanged 350 m3/h 510 m3/h 300mm flanged 800 m3/h 1200 m3/h Maximum pressure 500 mbar Connections GCR ..15 to 50 Female screwed GCR ..65 to 300 Flanged PN16 Closure time 1 sec. Valve body Diecast aluminium Ambient temperature 20 to + 60C Coil temperature Approx. 70C Cable entry PG11 Protection IP54 Weight 103 kg max.

When powered on, this range of normally closed gas solenoid valves open without manual intervention. On power loss, the valve automatically closes. FEATURES Spring shut off action Manual reset upon restart SPECIFICATION Power supply 230 VAC and 24 VAC options Voltage tolerance 15 to +10% Pressure drop Natural gas flow with pressure drop of: 0.5 mbar or 1 mbar 1/2 screw 5 m3/h 7 m3/h 3 3/4 screw 6.5 m /h 8.7 m3/h 1 screw 8.7 m3/h 11 m3/h 1 1/4 screw 16 m3/h 25 m3/h 1 1/2 screw 16 m3/h 25 m3/h 2 screw 37 m3/h 41 m3/h 65mm flanged 37 m3/h 51 m3/h 80mm flanged 37 m3/h 151 m3/h 100mm flanged 83 m3/h 125 m3/h 125mm flanged 170 m3/h 240 m3/h 150mm flanged 170 m3/h 240 m3/h Connections GCA ..15 to 50 Female screwed GCA ..65 to 150 Flanged PN16 Closure time 1 sec. Valve body Diecast aluminium Ambient temperature 15 to + 60C Coil temperature Approx. 70C Protection IP54 Weight 60 kg max. Part code PDCSY-VS-GCA-415 PDCSY-VS-GCA-420 PDCSY-VS-GCA-425 PDCSY-VS-GCA-432 PDCSY-VS-GCA-440 PDCSY-VS-GCA-450 PDCSY-VS-GCA-815 PDCSY-VS-GCA-820 PDCSY-VS-GCA-825 PDCSY-VS-GCA-832 PDCSY-VS-GCA-840 PDCSY-VS-GCA-850 PDCSY-VS-GCA-865 PDCSY-VS-GCA-880 Connection Max. press. Screwed Valves (24 VaC) Auto Reset Gas Valve (screwed) - 12 BSP, 200 mbar Auto Reset Gas Valve (screwed) - 34 BSP, 200 mbar Auto Reset Gas Valve (screwed) - 1 BSP, 200 mbar Auto Reset Gas Valve (screwed) - 114 BSP, 200 mbar Auto Reset Gas Valve (screwed) - 112 BSP, 200 mbar Auto Reset Gas Valve (screwed) - 2 BSP, 200 mbar Screwed Valves (230 VaC) Auto Reset Gas Valve (screwed) - 12 BSP, 200 mbar Auto Reset Gas Valve (screwed) - 200 mbar, 200 mbar Auto Reset Gas Valve (screwed) - 34 BSP, 200 mbar Auto Reset Gas Valve (screwed) - 1 BSP, 200 mbar Auto Reset Gas Valve (screwed) - 114 BSP, 200 mbar Auto Reset Gas Valve (screwed) - 112 BSP, 200 mbar Auto Reset Gas Valve (screwed) - 2 BSP, 200 mbar Flanged Valves (230 VaC) Auto Reset Gas Valve (flanged) - 65 mm, 360 mbar Auto Reset Gas Valve (flanged) - 80 mm, 360 mbar

Part code PDCSY-VS-GCR-415 PDCSY-VS-GCR-420 PDCSY-VS-GCR-425 PDCSY-VS-GCR-432 PDCSY-VS-GCR-440 PDCSY-VS-GCR-450 PDCSY-VS-GCR-815 PDCSY-VS-GCR-820 PDCSY-VS-GCR-825 PDCSY-VS-GCR-832 PDCSY-VS-GCR-840 PDCSY-VS-GCR-850 PDCSY-VS-GCR-865 PDCSY-VS-GCR-880

Description Screwed Valves (24 VaC) Manual Reset Gas Valve (screwed) - 12 BSP Manual Reset Gas Valve (screwed) - 34 BSP Manual Reset Gas Valve (screwed) - 1 BSP Manual Reset Gas Valve (screwed) - 114 BSP Manual Reset Gas Valve (screwed) - 112 BSP Manual Reset Gas Valve (screwed) - 2 BSP Screwed Valves (230 VaC) Manual Reset Gas Valve (screwed) - 12 BSP Manual Reset Gas Valve (screwed) - 34 BSP Manual Reset Gas Valve (screwed) - 1 BSP Manual Reset Gas Valve (screwed) - 114 BSP Manual Reset Gas Valve (screwed) - 112 BSP Manual Reset Gas Valve (screwed) - 2 BSP Flanged Valves (230 VaC) Manual Reset Gas Valve (screwed) -65 mm Manual Reset Gas Valve (screwed) - 80 mm

PDCSY-VS-GCA-8100 Auto Reset Gas Valve (flanged) - 100 mm, 360 mbar PDCSY-VS-GCA-8125 Auto Reset Gas Valve (flanged) - 125 mm, 360 mbar PDCSY-VS-GCA-8150 Auto Reset Gas Valve (flanged) - 150 mm, 360 mbar Accessories Closed Position Indicator Switch* PDCSY-VS-FCA-1 PDCSY-VS-FCA-2 PDCSY-VS-FCA-3 PDCSY-VS-FCA-4 PDCSY-VS-FCA-5 PDCSY-VS-FCA-6 PDCSY-VS-FCA-7 To suit 15-20 mm valves To suit 25 mm valve To suit 32-40 mm valves To suit 50 mm valve To suit 65-80 mm valves To suit 100 mm valve To suit 125-150 mm valves

PDCSY-VS-GCR-8100 Manual Reset Gas Valve (screwed) - 100 mm PDCSY-VS-GCR-8125 Manual Reset Gas Valve (screwed) - 125 mm PDCSY-VS-GCR-8150 Manual Reset Gas Valve (screwed) - 150 mm PDCSY-VS-GCR-8200 Manual Reset Gas Valve (screwed) - 200 mm PDCSY-VS-GCR-8300 Manual Reset Gas Valve (screwed) - 300 mm Datasheet PDCSY-VS-GCR.pdf

Datasheet PDCSY-VS-GCA.pdf * This option cannot be retro-fitted. It must be ordered at the same time as the PDCSY-VS-GCA gas valve.

46

Innovative Solutions for Greener Buildings

PDCSY-VS-PS

Gas Electro-hydraulic Valves

CM Series

Damper Actuators

A range of Class A 2-port, 2-position oil-filled Hydraulic Gas Valves for use in securing, limiting, shutting off and releasing gas supplies to atmospheric boilers, gas burners and similar equipment. Units are fitted with a closed position switch as standard. A manual reset switch option is available. SPECIFICATION Operating voltage Operating pressure Closure time Body material Media Pipework connections Power consumption Switch rating Ambient temperature Protection Weight Part code PDCSY-VS-PS6683 PDCSY-VS-PS6684 PDCSY-VS-PS6685 PDCSY-VS-PS6686 PDCSY-VS-PS6687F PDCSY-VS-PS6689F PDCSY-VS-PS-MRS 240 VAC +10% 15% @ 50/60 Hz 200 mbar max. Max. 1 second Die cast aluminium Non-corrosive gases Air or oil (up to 200s Redwood No.1) Up to 3 Screwed BSP female 4 and over Flanged to PN16 Opening 200 VA Fully open 18 VA 250 VAC or 30 VDC @ 5 (2) A 15 to + 60C IP54 60 kg max. Description Screwed Valves Gas Electro-hydraulic Valve (screwed) - 1 1/2" BSP Gas Electro-hydraulic Valve (screwed) - 2" BSP Gas Electro-hydraulic Valve (screwed) - 2 1/2" BSP Gas Electro-hydraulic Valve (screwed) - 3" BSP Flanged valves Gas Electro-hydraulic Valve (flanged) - 4" BSP Gas Electro-hydraulic Valve (flanged) - 6" BSP Accessory Manual reset switch Datasheet PDCSY-VS-PS.pdf

The revolutionary ultra-flat CM damper actuators now offer IP66 protection. That means they are protected against dust, dirt, high humidity and spray. With a height of just 16 mm (or 24 mm with position indicator), IP66 CM actuators will fit in places simply too small for others: for example devices, machines, ventilation outlets and exhaust air hoods. The new universal mounting bracket allows for amazingly fast installation. The angles of rotation can be freely selected from 0 to 315 or set to endless rotation as required. FEATURES Simple direct mounting on the damper spindle with a universal spindle clamp Overload-proof No limit switch required SPECIFICATION Alimentation 24 VCA to 50-60 Hz ou 24 VCC 230 VCA to 50-60 Hz Torque (nominal torque) Min. 2 Nm @ nominal voltage Running time 75 s / 90 Signaux de commande TOR / 3 points for SR Angle of rotation adjustable de 0 to 315 Ambient Temperature -30 to +50C Humidity 5 to 95% HR Protection IP54 Dimensions 158 x 56 x 28 mm Weight 220 g
Part code CM230-L CM24-L CM24-SR-L CM24-SR-R Description Actuator CM230 IP55 Actuator CM24 IP55 Actuator CM24-SR-L IP55 Actuator CM24-SR-R IP55

PDCSA-AVM

Actuators

The automatic adaptation to valve, precision control and high energy efficiency with minimal operating noise makes the AVM series the perfect drive for the actuation of through or three-way valves in the BUD and BUE DN65-150 series, for controllers with continuous output (010 V or 420 mA) or switching output (2-point or 3-point control). Depending on the type of connection, the AVM may be used as a continuous drive (0-10 V and/or 4-20 mA), as a 2-point drive (OPEN/CLOSED) or as a 3-point drive (OPEN/STOP/ CLOSED) with an intermediate position. FEATURES Pushing force of min. 2500 N Stepping motor with SUT (Sauter Universal Technology) electronic control unit and electronic load-dependent cut-off Automatic detection of control signal applied (continuous or switching), display via 2 LEDs The type of characteristic curve (linear, quadratic or equal percentage) can be adjusted in the drive Independent adaptation to valve stroke between 8 and 49 mm, captive even if the power is turned off Direction of travel can be selected via screw terminals when making electrical connection or remotely Coding switch for selection of characteristic and running time (35, 60 or 120 sec.) Hand crank for external manual adjustment with motor cut-off and as trip for re-initialisation Easy assembly with valve, spindle connection takes place automatically after application of control voltage Many adaptors allow assembly on third-party valves SPECIFICATION Power supply Power consumption Fluid temperature Ambient temperature Humidity Protection Response time for 3-point Weight
Part code PDCSA-AVM105SK004 PDCSA-AVM234SK003

24 VCA 20% - 50/60 Hz 24 VCC 15% 10 W 130C -10 to 55C 95% HR AVM 105 IP54 AVM 234 IP66 200 ms AVM 105 0.7 kg AVM 234 4.1 kg
Description Actuator of valves,SUT 24V,8 mm,30/65/120 s,250 N Actuator of valves VUE/BUE 24 V, 2500 N,0..50 mm

Tel: +33 (0) 4 78 45 01 23 Fax: +33 (0) 4 78 45 22 33 web: www.distech-controls.eu

47

Peripheral Programme

GM Series

Actuators

LM Series

Damper Actuators

The GM24, GM230 damper motors are used for operation of dampers in air conditioning plants. GM24: A two-position motor with one or two wire control. GM220: A two-position motor with two wire control. FEATURES Direct installation on the damper pivot axle using the universal clamp Manual operation Adjustable angle of rotation Overload protection Automatic stop at preset positions SPECIFICATION Supply voltage Power consumption Rating Protection class Connection Cable Control signal Measuring voltage Angle of rotation Torque Direction of rotation Running time Ambient temperature Sound level Maintenance Weight
Part code GM230A GM24A GM24A-SR

The LM24 (-S) , LM 230 (-S) damper motors are used for operation of dampers in air conditioning plants. LM24: A two-position motor with one or two wire control. LM230: A two-position motor with single wire control. FEATURES Simple direct installation on the damper pivot axle using the universal clamp Manual operation using the disconnection button Adjustable angle of rotation with mechanical stop Overload protection Automatic stop at preset positions SPECIFICATION

GM24 24 VAC/DC 20%, 50/60 Hz GM230 220 VAC, 50/60 Hz GM24 3W GM230 10 W GM24 6.5 VA (SR: 7 VA) GM230 12 VA IP 54 0.9 m, 3 x 0.75 mm2 (SR: 0.9 x 5 x 0.75 mm2) 0-10 V RI = 100 k Operating range 2-10 V 2-10 VDC ( 0.5 mA) for 0-100% angle of rotation Adjustable, max 95 Min 30 Nm Min 30 Nm (50 Hz) Selectable with change-over switch 80 to 180 s 20C to +50C Max 45 dB (A) Maintenance-free 2 kg
Description Actuator GM230 IP55 Actuator GM24 IP55 Actuator GM24 SR U5 IP55

Supply voltage Power consumption Rating Protection Connection Cable Angle of rotation Torque Min Running time Direction of rotation Position indication Ambient temperature Sound level Max Maintenance Weight
Part code LM230A LM230A-S LM1230A-SR LM24A LM24A-S LM24A-SR

24 VAC/DC 20%, 50/60 Hz 230 VAC, 50/60 Hz 2W 1W 3 VA 12 VA IP 54 1 m, 3 x 0.75 mm2 Adjustable max 95 4 Nm 80 to 110 s Selectable with change-over switch Mechanical 30C to +50C 35 dB (A) Maintenance-free 650 g
Description Actuator LM230 IP55 Actuator LM230 S IP55 Actuator LM230A SR U5 IP55 Actuator LM24 IP55 Actuator LM24 S IP55 Actuator LM24 SR U5 IP55

LF Series

Actuators with spring return

The spring return motor LF is used to guide smaller dampers into open or closed position in the event of power failures. The motor starts to run when the power supply is fed, whilst the retracting spring is tensioned at the same time. If the power supply is cut, the tension in the spring is released which returns the damper motor to its safety position. FEATURES Simple direct installation on the damper pivot axle using the universal clamp Adjustable angle of rotation with built-in mechanical stop Overload protection Automatic stop at preset positions SPECIFICATION Supply voltage Power consumption Rating Protection Connection Cable Angle of rotation Torque Min Running time Direction of rotation Position indication Ambient temperature Sound level Maintenance Weight
Part code LF230 LF230-S LF24 LF24-S LF24-SR LF24-SR-S

NM Series

Actuators

The NM24, NM230 damper motors are used for operation of dampers in air conditioning plants. NM24: A two-position motor with one or two wire control. NM230: A two-position motor with single wire control. FEATURES Simple direct installation on the damper pivot axle using the universal clamp Manual operation using the disconnection button Adjustable angle of rotation with mechanical stop Overload protection Automatic stop at preset positions SPECIFICATION Supply voltage Power consumption Rating Protection Connection Cable Angle of rotation Torque Running time Direction of rotation Position indication Ambient temperature Sound level Max Maintenance Weight
Part code NM230A NM230A-S NM230A-SR NM24A NM24A-S NM24A-SR

LF24 24 VAC/DC 20%, 50/60 Hz LF230 230 VAC, 50/60 Hz LF24 5 W (2.5 W) LF230 5 W (3 W) 7 VA IP 54 1 m, 2 x 0.75 mm2 Adjustable, max 95 4 Nm 40 to 75 s - spring return 20 s Selectable with right or left mount Mechanical 30C to +50C Max 50 dB (A) Maintenance-free 1.4 kg 1.55 kg
Description Actuator with spring return 230V 90 4Nm Actuator with spring return 230V 90 4Nm Actuator with spring return 24V 90 4Nm Actuator with spring return 24V 90 4Nm Actuator with spring return 24V prop. 4Nm Actuator with spring return 24V prop. 4Nm

NM24 24 VAC/DC 20% 50/60 Hz NM230 230 VAC 50/60 Hz NM24 3.5 W NM230 2W NM24 4 VA NM230 18 VA IP 54 1 m, 3 x 0.75 mm2 Adjustable, max 95 Min 8 Nm 75 to 150 s Selectable with change-over switch Mechanical 20C to +50C 35 dB (A) Maintenance-free 800 g
Description Actuator NM230 IP55 Actuator NM230 S IP55 Actuator NM230A SR U5 IP55 Actuator NM24 IP55 Actuator NM24 S IP55 Actuator NM24 SR U5 IP55

48

Innovative Solutions for Greener Buildings

S Series

Additional Auxiliary Switch

TF Series

Actuator with spring return

Auxiliary switches are used for limit indication or for the execution of breaking function for each required angle position. SPECIFICATION Number of switches 1 (alternating) 2 (alternating) Switching power 10 A (2.5 A) 250 VAC Connection Cable 1.0 m 3 x 0.75 mm2 6 x 0.75 mm2 Break point Adjustable for the entire damper motor rotation area 0-10 Presetting using scale is an option Set values can be locked Protection IP 54 Ambient temperature 30C to +50C Weight 150 g 210 g
Part code S1A S2A S2A-F Description Additional auxiliary swith 1 switch Additional auxiliary swith 2 switches Auxiliary switch unit suitable on the spring return actuators (2 switches, adjustable switching points, including adapter)

The TF series consists in spring return actuator for the operation of air dampers that perform safety functions (e.g. frost and smoke protection, hygiene, etc.) for building services installations FEATURES Simple direct mounting on the damper spindle with a universal spindle clamp Overload-proof No limit switch required SPECIFICATION Nominal voltage 100-240 VAC, 50/60 Hz Nominal voltage range 85-265 VAC Power consumption In operation 2.5 W @ nominal torque At rest 1.5 W For wire sizing 5 VA Connection Motor Cable 1 m, 2 x 0.75 mm2 Torque Motor Min. 2 Nm @ nominal voltage Spring return Min. 2 Nm Direction of rotation Selected by mounting L / R Angle of rotation Max. 95, adjustable 37-100% with built-in mechanical stop) Motor running time < 75 s (0 ... 2 Nm) Spring return running time < 25 s @ 20 ... 50C / max. 60s @ 30C Sound power level Motor Max. 50 dB (A) Spring return Approx. 62 dB (A) Service life Min. 60000 operations Position indication Mechanical Protection IP42 Ambient temperature range 30 ... +50C Non-operating temperature 40 to +80C Ambient humidity range 95% r.H., non-condensating (EN 60730-1) Maintenance Maintenance-free Weight 600 g
Part code TF230 TF230-S TF230-SR TF24 TF24-S TF24-SR Description Actuator with spring return 230V 90 2Nm Actuator with spring return 230V 90 2Nm Actuator with spring return 230V prop. 2Nm Actuator with spring return 24V 90 2Nm Actuator with spring return 24V 90 2Nm Actuator with spring return 24V prop. 2Nm

SM Series

Actuators

The SM damper actuators series are designed to operate air control dampers in ventilation and air-conditioning systems for building services installations FEATURES Simple direct mounting on the damper spindle with a universal spindle clamp Manual operation Adjustable angle of rotation with mechanical end stops Overload-proof Automatic stop SPECIFICATION Nominal voltage Nominal voltage range Power consumption Connection Cable Torque (nominal torque) Direction of rotation Angle of rotation Running time Sound power level Position indication Protection Ambient temperature range Non-operating temperature Ambient humidity range Maintenance Weight
Part code SM230A SM230A-S SM230A-SR SM24A SM24A-S SM24A-SR

100-240 VAC, 50/60 Hz 85-265 VAC 2.5 @ nominal torque 0.6 W 6 VA 1 m, 3 x 0.75 mm2 Min. 20 Nm @ nominal voltage Reversible with switch 0 or 1 Max. 95 , limited on both sides mechanically 150 s Max. 45 dB (A) Mechanical, pluggable IP54 30 to +50C 40 to +80C 95% r.H., non-condensating (EN 60730-1) Maintenance-free 1 kg

Description Actuator SM230 IP55 Actuator SM230 S IP55 Actuator SM230A SR U5 IP55 Actuator SM24 IP55 Actuator SM24 S IP55 Actuator SM24 SR U5 IP55

Tel: +33 (0) 4 78 45 01 23 Fax: +33 (0) 4 78 45 22 33 web: www.distech-controls.eu

49

Peripheral Programme

Thermistor Types and Compatibility Chart

Element Element Code Type A 10K3A1 Type II


ECL/ECB/ECC Series

Manufacturer Aquatrol Honeywell Johnson Satchwell Seachange Trend Cylon 

Room Outside (PDCSY-TT-1000) (PDCSY-TT-331)  T8120B T7416A, T7043E

Duct (PDCSY-TT-322)

Immersion (PDCSY-TT-341)  T7106A, T7043F

Clamp (PDCSY-TT-351) T7044C

Bullet (PDCSY-TT-555) T7076D

TE-6361V TE636GV-1 DOT10K2 DOS10K2 SEN/PR/OAT TE-TO DDT10K1 SEN/PR/DCT TE-TD DWT10K1 DST10K1 SEN/PR/IMM TE-TI

SEN/PTR/ROM TE-TS

SEN/PR/CLP TE-TC

SEN/FL 

10K4A1 Type 3
ECL/ECB/ECC Series

Andover Delta Controls  Siebe York <40C  Honeywell

TTS-S Series

PDCSY-TT-O Series PDCSY-TT-I Series PDCSY-TT-ST 

20K6A1

T7460H, T7470A AF20 DAF20 AF20, DRF20-S, T7416A1022 RF20 EGT430/F011

LF20

VF20T, VF20NT VF20L, VF20LN WPF20 T7425A

VF20A WPF20A

KFT20, KFT20B DKF20 EGT456/F011

PT100A
ECL/ECB/ECC Series

Sauter Serck 

EGT466/F011 EGT447/F011

Siemens/Landis & QAA100 Staefa QAA2010 E  PT1000A


ECL/ECB/ECC Series

QAC2010 T7416A1014 EGT401/F101

FK-TP/200 QAM2110 T7411 EGT446/F101 EGT446/F101

QAE2110 T7413 T7414 EGT411/F101

QAP2010

Honeywell Sauter Serck Siebe

T7412 EGT430/F101

EGT456/F101

TS-5811  EGT330/F101 EGT301/F101 EGT346/F101 EGT347/F101 EGT348/F101 QAM2120 DDT0001 QAM2140 FK-T1 EGT346/F101 EGT347/F101 EGT348/F101 QAE2120 DWT0001 DST0001 QAE2140 FT-T1 FA-T1 QAP2040 FTK-T1 CTN3060 EGT311/F101 EGT354/F101 EGT356/F101 QAP21, QAP22 QAZ21 DDU

 F
ECL/ECB/ECC Series

Cylon Ni1000A Sauter

G H K L M

Ni1000A/TCR (LAN1) SAT1 STA1 TAC1 2.2K3A1

Siemens/ Landis & Staefa Satchwell Landis & Staefa TAC  Ambiflex Johnson

QAA24/25/26/27 QAC22 QAA64 DRT, DU, DUS DUSF QAA2040 FR-T1 RTN3060 TE-6344P DOT0002 DOS0002 FW-T1

QAD22 QAD26

ETN3060 TE-6343P

DTN3060 TE-6341P TE-6341V TE-634GV-1

ITN3060 TE-6342P

N P Q R S T V W Y Z

3K3A1 30K6A1 50K6A1 100K6A1 SAT2 SAT3 SAT4 SIE1 STA2 10K NTC RCL/RCB Series

Alerton Drayton Ambiflex  York >40C  Satchwell Satchwell Satchwell Barber Colman  Siebe  Landis & Staefa Carel

MS-1000 Series TS-1050 A701 A702 A703 A704 

DR

DD

DW1202 DWS1301 DW1204 DWS1202

DO2202 

FR-T30

FO-T30

FK-T30

FT-T305 

50

Innovative Solutions for Greener Buildings

Thermistor Temperature Range


A - 10K3A1 (Type II)
ECL/ECB/ECC Series

B - 10K4A1 (Type 3)
ECL/ECB/ECC Series

C - 20K6A1

Sensor type: Thermistor, temp coef. negative Temp C 50 40 30 20 15 10 5 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 140 150 160 170 180 190 200

Sensor type: Thermistor, temp coef. negative Temp C 50 40 30 20 15 10 5 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 140 150 160 170 180 190 200

Sensor type: Thermistor, temp coef. negative Temp C 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 71120 67324 63749 60385 57218 54397 51429 48032 46258 43938 41719 39640 37676 36020 34067 32409 30841 29388 27954 26625 25387 24178 23047 21977 20962 20000 19085 18225 17404 16824 16384 16189 14491 13847 13235 12654 12010 11578 11076 10600 10148 9721.1 9314.5 8826.8 8557.5 8205.3 7899.3 7548.9 7243.1 6951.2 6672.6 6404.0 6148.9 5904.6 5671.4 5448.6 5235.7 5092.3 4837.8 4651.6 4473.9

D - PT100A

Sensor type: Platinum, temp coef. positive Temp C 50 40 30 20 15 10 5 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 320 330 340 350 360 370 380 390 400 401 402 403 80.3 84.3 88.2 92.2 96.1 100.0 103.9 107.8 109.8 111.7 115.5 119.4 123.2 127.1 130.9 134.7 138.5 142.3 146.1 149.8 153.6 157.3 161.0 164.8 168.5 172.2 175.8 179.5 183.2 186.8 190.5 194.1 197.7 201.3 204.9 208.5 212.0 215.6 219.1 222.7 226.2 229.7 233.2 236.7 240.1 243.6 247.0

E - PT1000A
ECL/ECB/ECC Series

F - NI1000
ECL/ECB/ECC Series

Sensor type: Platinum, temp coef. positive Temp C 50 40 30 20 15 10 5 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 320 330 340 350 360 370 380 390 400 401 402 403

Sensor type: Platinum, temp coef. positive Temp C 50 40 30 20 15 10 5 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 140 150 160 170 180 190 200 201 202 203 204 205

667828 335671 176683 96974 72895 55298 42314 32650 31030 29500 28054 26688 25396 24173 23016 21921 20885 19904 18974 18092 17257 16465 15714 15001 14325 13623 13053 12494 11943 11420 10923 10450 10000 9572 9165 8777 8408 8056 6530 5325 4367 3601 2985 2487 2082 1751 1480 1256 1070 916.1 787.0 678.6 587.3 510.1 444.5 388.6 340.8 300.0 234.1 184.8

441667 239831 135233 78930 61030 47549 37316 29490 28157 26891 25689 24547 23462 22430 21450 20517 19631 18787 17983 17219 16490 15797 15136 14507 13906 13334 12788 12268 11771 11297 10845 10413 10000 9606 9229 8869 8525 8197 6754 5594 4656 3893 3271 2760 2339 1990 1700 1458 1255 1084 939.6 817.2 713.0 624.1 547.9 482.5 426.0 377.2 298.1 238.0

803 843 882 921 961 1000 1039 1078 1117 1155 1194 1232 1271 1309 1347 1385 1423 1461 1498 1536 1573 1611 1648 1685 1722 1758 1795 1832 1868 1905 1941 1977 2013 2049 2085 2121 2156 2191 2227 2262 2297 2332 2367 2401 2436 2470

743 791 842 893 946 1000 1056 1112 1171 1230 1291 1353 1417 1483 1549 1618 1688 1760 1833 1909 1987 2066 2148 2232

Tel: +33 (0) 4 78 45 01 23 Fax: +33 (0) 4 78 45 22 33 web: www.distech-controls.eu

51

Peripheral Programme

Thermistor Temperature Range (cont)


G - LAN 1 (Ni1000A/TCR) H - SAT1
Sensor type: Thermistor, temp coef. negative Temp C 50 40 30 20 15 10 5 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 140 150 160 170 180 190 200 9719 9584 9349 8968 8708 8396 8031 7614 7525 7434 7341 7246 7150 7053 6954 6853 6752 6649 6545 6440 6334 6228 6121 6013 5905 5786 5684 5580 5471 5362 5254 5147 5039 4933 4827 4721 4617 4513 4012 3545 3117 2730 2386 2082 1816 1585 1385 1213 1064 937 828 734 654 585 525 474 429 391 329 281

K - STA1

Sensor type: Nickel, temp coef. positive Temp C 50 40 30 20 15 10 5 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 150 170 180 190 200 790.8 826.8 871.7 913.4 934.7 956.2 978.0 1000.0 1004.4 1008.9 1013.3 1017.8 1022.3 1026.7 1031.2 1035.8 1040.3 1044.8 1049.3 1053.9 1058.4 1063.0 1067.6 1072.2 1076.8 1081.4 1086.0 1090.7 1095.3 1100.0 1104.6 1109.3 1114.0 1120.0 1123.4 1128.1 1132.9 1137.6 1161.5 1185.7 1210.2 1235.0 1260.1 1285.4 1311.1 1337.1 1363.5 1390.1 1417.1 1444.4 1472.0 1500.0 1528.3 1557.0 1586.0 1625.4

Sensor type: Thermistor, temp coef. positive Temp C 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 2226 2236 2246 2256 2266 2276 2286 2298 2306 2316 2326 2337 2347 2357 2367 2377 2388 2398 2408 2418 2429 2439 2449 2460 2470 2480 2491 2501 2512 2522 2532 2543 2553 2564 2574 2585 2596 2606 2617 2627 2638

M - 2.2K3A1

Sensor type: Thermistor, temp coef. negative Temp C 50 40 30 20 15 10 5 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 140 150 160 170 180 190 200 150395 75593 39789 21839 16416 12453 9529 7353 6988 6643 6318 6010 5719 5444 5183 4937 4703 4482 4273 4075 3886 3708 3539 3378 3226 3081 2940 2814 2690 2572 2460 2353 2252 2156 2064 1977 1893 1814 1471 1199 983.4 810.9 672.2 560.1 468.9 394.5 333.3 282.9 241.1 206.3 177.2 152.8 132.3 114.9 100.1 87.51 76.75 67.52 52.72 41.61

N - 3K3A1

Sensor type: Thermistor, temp coef. negative Temp C 50 40 30 20 15 10 5 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 140 150 160 170 180 190 200 200348 100701 53005 29092 21868 16589 12694 9795 9309 8850 8416 8006 7619 7252 6905 6577 6266 5971 5692 5428 5177 4940 4714 4500 4297 4105 3916 3748 3583 3426 3277 3135 3000 2871 2749 2633 2522 2417 1959 1598 1310 1080 895.5 746.2 624.7 525.5 444.0 376.9 321.2 274.8 236.1 203.6 176.2 153.0 133.3 116.6 102.2 89.95 70.23 55.44

P - 30K6A1

Sensor type: Thermistor, temp coef. negative Temp C 50 40 30 20 15 10 5 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 140 150 160 170 180 190 200 2497K 1219K 622911 331876 245785 183697 138502 105305 99787 94588 89689 85069 60713 76604 72726 69064 65608 62347 59257 56346 53585 50978 48511 46178 43969 41877 39895 38019 36240 34554 32955 31438 30000 28635 27339 26108 24939 23828 19046 15317 12390 10079 8243 6777 5600 4650 3879 3251 2737 2313 1963 1672 1430 1228 1058 914.6 793.2 690.2 527.4 407.7 -

L - TAC1

Sensor type: Thermistor, temp coef. negative Temp C 0 5 10 15 20 25 30 35 40 50 60 70 80 90 100 110 120 130 5085 4078 3294 2676 2188 1800 1488 1237 1034 740 540 400 300 230 180

52

Innovative Solutions for Greener Buildings

Thermistor Temperature Range (cont)


Q - 50K6A1
Sensor type: Thermistor, temp coef. negative Temp C 50 40 30 20 15 10 5 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 140 150 160 170 180 190 200 4168K 2033K 1038K 553243 409689 306183 230842 175508 166310 157644 149480 141779 134521 127669 121207 115105 109344 103903 98761 93901 89307 84962 80851 76961 73280 69794 66492 63364 60400 57589 54925 52398 50000 47724 45564 43513 41565 39714 31744 25529 20650 16799 13740 11297 9334 7751 6466 5419 4560 3855 3271 2787 2384 2046 1762 1523 1321 1149 878.2 678.8

R - 100K6A1

Sensor type: Thermistor, temp coef. negative Temp C 50 40 30 20 15 10 5 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 140 150 160 170 180 190 200 8337K 4067K 2077K 1106K 819378 612366 461683 351017 332619 315288 298959 283558 269041 255337 242414 230210 218688 207807 197521 187803 178613 169924 161702 153923 146560 139588 132984 126729 120799 115179 109850 104796 100000 95449 91128 87026 83129 79428 63489 51058 41301 33598 27479 22593 18669 15502 12932 10837 9121 7710 6543 5574 4767 4092 3525 3047 2642 2299 1756 1357

S - SAT2

Sensor type: Thermistor, temp coef. negative Temp C 50 40 30 20 15 10 5 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 140 150 160 170 180 190 200 2094 2079 2061 2046 2027 2010 1992 1973 1951 1934 1911 1897 1872 1851 1810 1809 1787 1764 1740 1716 1690 1667 1644 1621 1598 1574 1549 1524 1500 1476 1452 1336 1219 1113 1011

T - SAT3

Sensor type: Thermistor, temp coef. negative Temp C 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 45 50 55 60 65 70 75 80 85 90 95 100 2708 2681 2659 2618 2616 2592 2567 2544 2520 2496 2474 2447 2423 2398 2372 2346 2322 2296 2269 2243 2216 2086 1950 1818 1694 1758 1461 1353 1258 1171 1089 1020 950

W - SEI1

Sensor type: Thermistor, temp coef. negative Temp C 50 40 30 20 15 10 5 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 140 150 160 170 180 190 200 10732 10517 10172 9654 9320 8933 8496 8044 7910 7807 7702 7596 7489 7381 7271 7161 7050 6938 6825 6712 6598 6485 6370 6256 6141 6028 5913 5798 5686 5573 5461 5349 5238 5128 5019 4910 4803 4696 4185 3707 3271 2875 2521 2206 1929 1685 1472 1287 1127 986 866 760 670 590 522 462 410 365 290 233

Y - STA2

Sensor type: Thermistor, temp coef. positive Temp C 0 5 10 15 20 25 30 35 7490 6340 5360 4540 3840 3250 2750 2320

Z - 10K NTC
RCL/RCB Series

Sensor type: Thermistor, temp coef. negative Temp C 30 20 10 0 10 20 25 30 35 40 50 60 70 80 110788 67651 42421 27278 17960 12091 10000 8311 3942 5825 4158 3018 2226 1667

V - SAT4

Sensor type: Thermistor, temp coef. negative Temp C 10 5 0 5 10 15 20 1733 1617 1504 1397 1298 1208 1128

Tel: +33 (0) 4 78 45 01 23 Fax: +33 (0) 4 78 45 22 33 web: www.distech-controls.eu

53

Peripheral Programme

Notes:

54

Innovative Solutions for Greener Buildings

Notes:

Tel: +33 (0) 4 78 45 01 23 Fax: +33 (0) 4 78 45 22 33 web: www.distech-controls.eu

55

Innovative Solutions for Greener Buildings

Distech Controls SAS, Europe - Africa Business Centre, 17 rue du Pr Magne, ZA Les Andrs - CS7001, 69126 Brindas - FRANCE Tel: +33 (0)4.78.45.01.23 - Fax: +33 (0)4.78.45.22.33 - www.distech-controls.eu

You might also like