You are on page 1of 61

LOGIQ S7

Signature Series

Amazing versatility

Challenging ultrasound environment


Patient challenges
> >

Obese and aging population More difficult to image Faster and more efficient procedures More data to manage Right equipment and training Work related injuries Cramped exam rooms Portables and bedsides Budget constraints ROI and life cycle costs

Time constraints
> >

Staff needs
>

>

Physical environment
> >

Economic pressures
> >

GE Ultrasound strategy
Clinical focus
LOGIQ
General Imaging

Voluson
Womens Health

Vivid
Cardio-vascular

Venue
Point of Care

V-scan
Primary Care

Viewpoint
Ultrasound IT

Extraordinary images

Extraordinary images

Extraordinary images

Extraordinary images

Extraordinary images

Ultrasound-specific productivity

Easy workflow
Image fusion and scan automation

Exceptional 4D
Advanced automation

4D heart in a single beat


Advanced quantitative tools

Easy to use
Easy to clean

Take a look
Size/weight of a soda can

Easy Workflow
Plug-ins for popular PACS

GE Ultrasound
Compact
Venue 40 LOGIQ e Vscan

General Imaging products

LOGIQ E9
2009

LOGIQ S8
2011

LOGIQ S7 LOGIQ P5
2005

LOGIQ P6
2007

2012

LOGIQ S7

Leading with versatility


Quality performance in an easy to use and budget friendly design

Sensational performance
Consistent quality performance across applications

Smart design
User-sensitive design for comfort and productivity

Specialized capabilities
Tailored solutions for daily clinical challenges

Sensational performance

LOGIQ S7
>

LOGIQ S7

Amazing versatility
S-Agile architecture
>

Migrates the Agile Acoustic Architecture from our leadership system into a lightweight portable design Enables advanced Transducer Technologies

Advanced transducers
>

A wide range of LOGIQ E-Series transducers enables quick acquisition of sensational images

Image optimization tools


> >

Help enhance image quality such as increased contrast resolution, border definition and signal to noise ratio Auto optimization tools help improve consistency and productivity

Smart design

LOGIQ S7
Design
>

LOGIQ S7

Amazing versatility
For comfort and productivity
- Lightweight, small footprint, easy to move - Four active probe connectors - Three cabinet solutions

System adjustability
>

According to operator height and preference:


- Up/down and swivel of operator panel - Independent positioning of 19 LCD monitor

Intuitive interface
> >

LOGIQ design operator panel with 7 wide touch screen Backlit controls and smart keys
Scan Assistant feature Smart keys

Workflow enhancements
> >

Specialized capabilities

10

LOGIQ S7

LOGIQ S7

Amazing versatility
Advanced tools to help provide innovative and in-depth care.
Specialized features
> > > > > > >

B-Flow/B-Flow Color Elastography with semi-Quantification Flow Quantification Contrast Imaging 3D/4D Ultrasound B-Steer+ Automatic IMT

Specialized Transducers Raw Data image processing Multi-modality Query Retrieve

11

LOGIQ S7
Abdominal/Gastroenterology

Liver mass detection in arterial phase using CEUS with C1-5-D transducer.

Vascularization of spleen with B-Flow color using C1-5-D.

Detailed bowel examination with 9L-D.

12

LOGIQ S7
Radiology

Uniform liver Imaging with C1-5-D from near to far field

True hemodynamics seen in vascular Imaging with B-Flow color and 9L-D probe

Delineation of multiple breast lesions using ML6-15 probe

13

LOGIQ S7
Vascular

ATA hemodynamics with PW using 9L-D

ICA hemodynamics with B-Flow Color using 9L-D

3D visualization of liver veins with Glass body mode using RAB4-8-D

14

LOGIQ S7
Musculoskeletal

Superficial micro-vascularization with B-Flow color using L8-18i-D

Extended field of view with 11L-D using LOGIQView option

Representation of biceps tendon with ML6-15 probe

15

LOGIQ S7
Small Parts

Definition of breast lesion using 11L-D

Stiffness representation of thyroid lesion using Elastography option with ML6-15

Lesion differentiation in breast using ML6-15

16

LOGIQ S7
Cardiology

Cardiac hemodynamics demonstrated in apical view using 3Sp-D

Assessment of wall motion using TVI/TVD option with 3Sp-D

2D image shown using Stress Echo option with 3Sp-D

17

LOGIQ S7
OB/GYN

Detail in fetal face using RAB4-8-D to help enhance diagnostic confidence

Endocavitary Imaging using IC5-9-D probe

2D image uniformity from near to far field demonstrated with IC5-9-D

18

Customer care

19

LOGIQ S7

Leading with versatility


Tailored solutions to help you face your daily challenges
> > > > >

LOGIQClub community and Educational services Product upgrade strategy Financial solutions Service and care Global remote support

20

LOGIQ S7
Signature Series Amazing Versatility Its sleek, lightweight design incorporates powerful technologies while enhancing workflow and user experience. All at an affordable price that helps meet expectations.

The LOGIQ S7 has not been cleared by the U.S. FDA and is not available for promotion or sale in the United States.

21
DOC1134687

22

Traditional Ultrasound
Rigid assumptions about how sound interacts with the body.
> > > > >

LOGIQ S7

Speed of sound is constant (1540 m/s) Sound attenuation is constant Ultrasound beam is pencil shaped Vessels are straight Blood Flow is laminar

Looking at the body as a phantom

Reality is not so simple:


> > > >

Simplifying assumptions can lead to:


> > >

Sound attenuation and velocity vary Ultrasound beam is a volume Vessels are tortuous Blood flow can be turbulent

Poor image quality Distortion of image geometry Lots of adjustments to optimize images

23

LOGIQ S7

Agile Acoustic Architecture


New, flexible clinically-based mathematical models of the body. Dynamically optimizes image acquisition for every body type. Including the reality of body types.
>

Agile Acoustic Architecture Powerful New Acquisition System

>
>

Speed of sound is variable: 1450-1560 m/s Sound attenuation varies based on tissue type Ultrasound beam is dynamic

New Dynamic Mathematical Model

24

LOGIQ S7

Agile Acoustic Architecture


Agile System

Agile Architecture
Leadership Core Technology for advanced clinical applications

Migration of Technology with focus on daily customer needs

S-Agile Architecture
Streamlined Size & Technology to fit daily customers workflow

S-Agile System

25

LOGIQ S7

Agile Acoustic Architecture


Helping improve your diagnostic confidence Clinical benefits
> > > >

Image uniformity Spatial resolution High frequency Imaging at depth Reduced keystrokes to help optimize the image

S-Agile

Agile

Traditional

Traditional

26

LOGIQ S7

E-Series Transducers
Innovative Technologies
> > > > >

Light weight polymers Designed for proper grip Flexible, light weight cable Pin Less connectors Probe compatibility

27

E-Series Transducers
Wide range of applications
Clinical application Abdominal Vascular Cardiology OB/GYN Breast Small Parts Pediatrics/Neonatal Transducer C1-5-D, 3CRF-D, 9L-D ML6-15*, 9L-D, P2D, P6D 3Sp-D, P2D RAB4-8-D, C1-5-D, IC5-9-D ML6-15*, 11L-D ML6-15*, 11L-D, L8-18i-D 8C, S4-10-D*

LOGIQ S7

Urology
Intraoperative
*only on the LOGIQ S7 Expert

IC5-9-D
L8-18i-D

28

LOGIQ S7

E-Series Transducers
Innovative Technologies
Conventional Array Active Matrix Array

ML615
High frequency linear transducer
Matrix arrays provide multiple rows of crystals, allow focusing in the near, mid and far field. Great spatial resolution and image uniformity from near to mid field Footprint 50 mm Ultra High Doppler & Color frequency for exclusive slow flow sensitivity

29

LOGIQ S7

E-Series Transducers
Acoustic Amplifier
Traditional Technology
Lens Cover Coupling layers Composite PZT Backing

Acoustic Amplifier Technology


Lens Cover Coupling layers Composite PZT

New Acoustic Amplifier


Backing

Recaptures the unused energy that passes through the crystal. Improves sensitivityaxial resolution & penetration over traditional transducers

30

LOGIQ S7

E-Series Transducers
Single Crystal
Traditional PZT Technology The variations of polarization in PZT affect its piezoelectric properties and signal to noise ratio

Single Crystal Technology Single crystal material exhibits fewer poling variations

The electric dipoles of PZT are randomly oriented introducing signal noise

Single Crystal exhibits improved dipole alignment Increased bandwidth Better signal to noise ratio Improved axial resolution and penetration

31

Speckle Reduction Imaging


Speckle What it is
> >

LOGIQ S7

Inherent artifact to ultrasound Imaging Created by interference of energy from scatterers too small to be resolved by conventional ultrasound systems

Speckle Why it is bad


>

>

No one-to-one correspondence between speckle brightness and strength of scatter Degrades spatial and contrast resolution obscuring diagnostic information

Optical Image of Liver

Ultrasound Image of Liver

32

Speckle Reduction Imaging


Enhance
> >

LOGIQ S7

Smoothes along preferred edge direction Does not smooth across edge

Suppress
> >

Reduces variation within speckle region Maintains local mean gray scale level

33

Speckle Reduction Imaging


Speckle Reduction Imaging = Raw Data processing The SRI feature can be turned on/off and levels changed:
> > >

LOGIQ S7

on live images on frozen images on images recalled from the archive

34

CrossXBeam
Spatial Compounding Imaging
Spatial Compounding Technology
>

LOGIQ S7

Images obtained from up to 9 different scanning angles combined into one image in Real Time

Clinical benefits*
> > > >

Improved image contrast for greater tissue differentiation Improved visualization of borders and interfaces Reduced clutter artifact, known in difficult-to-scan patients Enhanced biopsy needle visualization

* Comparison with fundamental B-Mode

35

CrossXBeam
Spatial Compounding Imaging
More scanning angles advantages*
>

LOGIQ S7

>

>

Greater chance one angle will be perpendicular to round or oval reflectors Greater smoothness of borders and improved contrast resolution Noise and speckle change randomly with steering angle - will be averaged out

* Comparison with fundamental B-Mode

Min, Max, Hybrid level depending on settings.

36

CrossXBeam
Spatial Compounding Imaging
Helps increase clinical confidence in all Imaging modes
> >

LOGIQ S7

>

CrossXBeam is a standard feature CrossXBeam is available on all linear and convex transducers Active with Color flow and PW Doppler Virtual convex LOGIQView Easy and Advanced 3D Speckle reduction Imaging SRI-HD B-Steer+

37

System adjustability
LOGIQ S7 can be modified according to operator height and preference: the control panel swivels and moves up/down independently from the monitor for easy positioning, and the 19 LCD monitor on an articulated arm helps users attain an excellent viewing angle.

LOGIQ S7

Cabinet solutions
> > >

Low cabinet: DVR drive Mid cabinet: DVR + b/w printer or drawer High cabinet: DVR + b/w printer or drawer + color printer Low cabinet 630 1030 mm Mid cabinet 760 1030 mm High cabinet 830 1030 mm +/- 30 degrees Elevation 150 mm, translation +/- 250 mm Fold down for transportation
90kg/198lbs 790mm 630mm 1030mm

Operator panel elevation* and swivel


> > >
1750mm

>

Articulating monitor arm*


> >

*only on the LOGIQ S7 Expert

38

System interface
Intuitive interface
> >

LOGIQ S7

LOGIQ design operator panel with 7 wide touch screen Backlit controls and smart keys

Workflow enhancements
> >

Scan assistant feature Smart keys


Keys A and B Imaging Mode Live B, B-Flow CF, TVI, B-Flow Color PWD, CW, TVD M/D cursor Symbols Function Focal Zone Up/Down Box Steer Baseline Up/Down Sample volume size

39

LOGIQ S7

Scan Assistant
> > > >

>

The personal assistant to users exam Up to 63% time reduction Up to 87% keystroke reduction Help increase exam consistency Compatible with LOGIQ E9 and LOGIQ S8 workflows

Initiates and completes user selected required measurements

Automatically steers Color Doppler

Rt CCA

Automatically sets up Imaging controls and modes

Automatically inserts comments

Automatically reorders images to readers preference

*Third party evaluation conducted on LOGIQ S7 comparing traditional scan and scan using Scan Assistant.

40

LOGIQ S7

Scan Assistant

41

B-Flow/B-Flow Color
A GE innovation
> > > >

LOGIQ S7

Not using Doppler processing Based on GE Patented Coded Technology Display real hemodynamics Direct visualization of blood reflectors

True hemodynamics and anatomy


> > >

> >

Dynamic appearance of flow Minimal tissue overwrite compared to Color Flow Better control of flash artifacts compared to Color Flow Clearly visible background image Independent mode control

42

LOGIQ S7

B-Flow/B-Flow Color
Benefits over Doppler
> > > > >

No tissue overwrite No impact on frame rate Less angle dependency High resolution Imaging Background image clearly visible

Available on Transducers
> > >

>
>

C1-5-D 9L-D 11L-D ML6-15 L8-18i-D

43

LOGIQ S7

Elastography
Strain Imaging Technology requiring a light manual compression or patient breath to perform tissue deformation. A qualitative and semi-quantitative solution.

Highlights:
> > > > >

Elasticity = Stress Strain


Stress = axial force applied to lesion Strain = tissue deformation due to applied stress

High sensitivity and persistence Consistent pattern User selectable color maps Dual measurements User support by pressure quality bar and graph

This soft lesion deforms under pressure.

This hard lesion does not deform under pressure.

Available on the following Transducers:


> > > > >

9L-D (Small Parts, Abdomen, MSK) 11L-D (Small Parts, Breast, MSK) ML6-15 (MSK, Small Parts) IC5-9-D (Urology, Gyn) C1-5-D (Abdomen)

44

LOGIQ S7

Elastography
Semi-Quantification
E-Index
> > > >

Selected ROIs elasticity value Round or manual tracing of ROI E-index range from 0 6 Based on GE Raw Data Processing

E-Ratio
> >

Calculated E-Index between ROIs (up to 8) Representing relative stiffness

Q-Analysis over multi-frame acquisition


> > >

Automatic skip of low quality frames Anchor function Trace export in ASCII format

*Elastography with semi-Quantification has not been cleared by the U.S. FDA and is not available for promotion or sale in the United States.

45

LOGIQ S7

Flow Quantification
2D CFM/PDI Quantitative assessment of vascular feeding in a selected ROI.

Highlights:
> > >

Consistent, repeatable and objective measurement Can help in treatment planning and monitoring protocols Provides Data to support outcome measurements

Features:
> > > >

>
>

Up to 8 selectable ROIs Analysis over 4/5 heart beat cycles Automatic or manual ROI tracing Save ROI feature for monitoring Manual disabling & enabling of frames Export traces in ASCII format

46

Contrast Imaging
Amplitude Modulation Technique
>

LOGIQ S7

>
>

Great penetration and contrast sensitivity Excellent tissue suppression High image uniformity

Imaging Modes
> > >

Dual or single display Hybrid contrast Accumulation

Features
> >

>
>

Dual caliper, dual timer TIC Q-analysis package Retrospective/prospective storage One button background storage

Available for C1-5-D probe (Abdominal studies)

*Contrast Enhanced Ultrasound has not been cleared by the U.S. FDA and is not available for promotion or sale in the United States.

47

Contrast Imaging
Time intensity Curve (TIC)
> >

LOGIQ S7

> > > > > >

Raw data processing for Contrast uptake Q-Analysis of both compressed and uncompressed data Up to 8 selectable ROIs Up to 10 parameters Ellipsoid or manual ROI tracing Anchor tracking function Automatic enabling/disabling of frames Trace export in ASCII format

TIC Q-Analysis

48

3D/4D Ultrasound
GE Volume Imaging with 3D/4D dedicated Hybrid abdominal transducer

LOGIQ S7

Highlights:
> > >

Easy, quick, reproducible High Volume Data accuracy Comprehensive settings

Volume Modes:
> > > > >

Multi-Planar Imaging Surface Rendering TUI Tomographic Ultrasound Imaging VCI Volume Contrast Imaging VOCAL Volume Calculation

49

3D/4D Ultrasound
TUI Tomographic Ultrasound Imaging
Visualization mode that presents data as parallel slices (planes) through acquired Volume dataset. It works with CFM/PDI and SRI-HD.

LOGIQ S7

Highlights:
>
> >

Information consistent to CT & MR format


3D static with Colour Up to 9 slices, with user selectable distance (min 0.5 mm, step by 0.1 mm) and angle Top left held as Reference Image Works with SRI

> >

50

3D/4D Ultrasound
VCI Volume Contrast Imaging
VCI is a Volume acquisition technique improving B-Mode contrast resolution and speckle suppression.

LOGIQ S7

Results:
Help improve assessment of lesions size, margins and internal structures for a more comprehensive patient management.

51

3D/4D Ultrasound
Vocal
Vocal is a Volume Computer-aided analysis based on a Volume acquisition enabling fast and accurate Volume calculations.

LOGIQ S7

Highlights:
> > > >

Manual, Semi automatic or Automatic borders definition Basic measurements as length, angle and area Easy corrections and contour modifications Can be used with any lesion or volume to measure

52

B-Steer+
B-Steer+ feature enables enhanced visualization of the needles structure during interventional procedures, helping improve user confidence and exam accuracy.

LOGIQ S7

Highlights:
> >

>
>

Up to 12 selectable steering angles available (six each direction) Separate gain control for needle reflection Available on all linear transducers Quick One-button operation

53

Automatic IMT
Auto IMT is an automated method of measuring the intima media thickness of the CCA or ICA from multiple samples across a user defined length.
>
>

LOGIQ S7

>

>

Simple and easy to operate Direct export of measurements to a worksheet and report page Including ECG trigger to help increase consistency and reliability Save offset distance and IMT measurement lengths to help increase reproducibility

54

Raw Data processing


Original Acoustic Data are stored before Scan Converting in a GE Raw Format to be easily accessed and re-processed any time after the exam completion.

LOGIQ S7

Highlights:
> > >

Sub-optimal studies can be optimized Measurements can be re-done and reports regenerated All Imaging control parameters can be changed as:

B-Mode: Gain, DR, AO, Zoom, SRI CFM: Gain, Threshold, DualView, DR PW: Baseline, Invert, Angle, DR, Gain

55

Multi-modality Query Retrieve


Live Ultrasound comparison with retrieved CT or MRI Volume dataset
> > > >

LOGIQ S7

Potential time saver Simplified workflow Complementarity of information Helps improve diagnostic confidence

Perform Live Ultrasound

Retrieve modality datasets Scan in Dual Display with Live US

56

LOGIQClub users community


www.LOGIQClub.net
Access to the Club websites
Local contents, events Clinical courses in your country Application tips & tricks Publications and cases & papers Clinical cases & technical presentations Downloadable educational materials and DVD

User Days & VIP Lounges


Learn about best practices from specialists around the globe Discuss and exchange information with ultrasound users worldwide

Personalized Mailings and Newsletters


Be first to learn about new Ultrasound products and software upgrades

57

Flexible solutions
Service and Care

Flexible solutions
Service and Care
Diagnose with speed, repair with confidence Live, real time technical support Local repair depot Remote monitoring and assistance Excellent support fitting your budget

Entry level Services package Fully comprehensive support Parts and labour included

Rapid, reliable personalized response Local Customer solution centres Direct line with a dedicated Customer care specialist Technical trainings

For a long lasting stable collaboration Basic and advanced trainings to optimize system performance

Flexible solutions
Service and Care

Web Services Connectivity - InSite with ExC

Flexible solutions
Service and Care
Technical support
Help improve Equipment Uptime Error Log download Real-time diagnosis & parts identification Automated Software Updates (to follow)

Security
Secure Data Transfer Customer initiates connection Respect your security processes

Applications support
On screen remote application support Trial & activate new application features

You might also like