You are on page 1of 85

Contents

Moeller HPL0211-2007/2008

7/1
Rotary switches T, switch-disconnectors P, Small enclosures CI-K, empty enclosures CI

Rotary switches T, switch-disconnectors P, Small enclosures CI-K


ATEX

Rotary switches, switch-disconnectors

Mini rotary switches

Small enclosures, empty enclosures

Page Technical overview 7/2 7/4 7/4 7/6 7/8 7/8 7/9 7/10 7/21 7/25 7/30 7/32 7/33 7/34 7/35 7/37 7/38 7/40 7/40 7/41 7/43 7/44 7/45 7/46 7/48 Technical overview Description Key to part numbers, modular system System overview Ordering Control circuit isolator, ON/OFF switch Changeover switch, hand/automatic switch Control switch, step switch Control switch - group switch, ON (OFF) button, reversing switch, coding switch Locks, front plates Technical data Dimensions

Page 7/2 7/9 7/9 7/52 7/54 7/54 7/55 7/56 7/58 System overview Ordering Basic enclosures Accessories Technical data Dimensions

Page 7/60 7/61 7/61 7/64 7/75 7/88

The powerful, rugged and compact cam switches and switch-disconnectors are used in industry, workshops and in building services management. The basic switch types of four different construction types and with a wide range of standard contact sequences and rating ranges are available.

System overview Rotary switches Switch-disconnectors Description Key to part numbers, modular system Ordering Load current switches, main switches, maintenance/repair switches Load current switches, ON/OFF switches Load current switches, changeover contacts Load-current switch - Safety switch

7/59 7/74 7/88

TM/T rotary switches


- up to 10/132 kW - Non-standard circuits possible (EK) - Various types of construction Page 7/52

Load current switch - reversing switch Load current switches, (reversing) star-delta switches load-current switch - pole-change switch Control switch, step switch Control switch: ON/OFF switch, changeover, hand/auto switch Control switch - hand/auto switch

Switch for ATEX Zone 22


- TT rotary switches - P1 and P3 switch-disconnectors - Degree of protection IP65 Page 7/4

Control switch - ON buttons, universal control switches Control switch - instrument selector switches Switch with locking mechanism Main switch assembly kits, thumbgrip, maintenance key Front plates Add-on front plates key operation, locking interlock Neutral conductor, auxiliary contact, central mounting accessories, service distribution board mounting accessories Coupling drive, interlock parts, shaft extension Shrouds, keys Insulated enclosures, accessories Technical data Switch-disconnectors

7/49 7/50 7/51 7/67 7/67 7/69 7/70 7/76

P switch-disconnectors
- Up to 110 kW and 315 A - P1 and P3 in IP65 enclosure - 4 different types of construction Page 7/6

CI-K enclosure system


Switch protection in IP65 Individual laser inscription Customized cutouts Cable entry as push-through diaphragm or - knockout Page 7/60

Switch-disconnectors, auxiliary contacts Rotary switches Dimensions

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

7/2
Rotary switches, switch-disconnectors

Technical overview (Mini) Rotary switch, switch-disconnector


T, P, TM
Switch, basic type Max. rated operatioal power AC-23 A, 400/415 V, 50/60 Hz Max. rated operational current Iu Part no. Moeller HPL0211-2007/2008 TM 3.0 kW 10 A T0 6.5 kW 20 A http://catalog.moeller.net T3 13 kW 32 A T5(B) 22 kW 63 A http://catalog.moeller.net T5 30 kW 100 A T6 55 kW 160 A Moeller HPL0211-2007/2008 T8 132 kW 315 A P1-25 13 kW 25 A P1-32 15 kW 32 A

Technical overview (Mini) Rotary switch, switch-disconnector


T, P, TM
P3-63 37 kW 63 A P3-100 50 kW 100 A P5-125 45 kW 125 A P5-160 55 kW 160 A P5-250 90 kW 250 A P5-315 110 kW 315 A

7/3
Rotary switches, switch-disconnectors

Load current switches Main switch, maintenance/manual override switch On-Off switches Safety switches with warning label Changeover switches Reversing switches with 0 (Off) position Star-delta switches Reversing star-delta switches Multi-speed switches Reversing multi-speed switches Control switches Step switches On-Off switches Changeover switches Hand/Auto switches Spring-return switches Universal control switch Coding switches Series switches Instrument selector switches Group switches On-Off switches, spring-return Reversing switches Switches with interlocks Panic switchs without Emergency-Stop function On-Off switches without Emergency-Stop function Non-standard switches

a 7/54 a 7/56 a 7/55 a 7/55 a 7/58 a 7/58 a 7/58 a 7/58

a 7/10 a 7/21 a 7/25 a 7/32 a 7/33 a 7/33 a 7/34 a 7/33 a 7/35 a 3/37 a 3/37 a 3/37 a 7/39 a 7/39 a 7/40 a 7/40 a 7/40 a 7/41 a 7/42

a 7/10 a 7/21 a 7/25 a 7/32 a 7/33 a 7/33 a 7/34 a 7/33

a 7/10 a 7/21 a 7/30 a 7/26 a 7/32 a 7/33 a 7/33 a 7/34 a 7/33

a 7/12 a 7/24 a 7/30 a 7/26

a 7/15 a 7/26

a 7/15 a 7/26

a 7/10 a 7/21 a 7/30 a 7/41 a 7/42

a 7/10 a 7/22 a 7/30 a 7/41 a 7/41

a 7/10 a 7/22 a 7/30

a 7/11 a 7/22 a 7/30

a 7/11 a 7/22

a 7/11 a 7/22

a 7/11 a 7/22

a 7/12 a 7/22

a Electronic catalogue, http://catalog.moeller.net

a Electronic catalogue, http://catalog.moeller.net

Mounting form Surface mounting

/I
ATEX

Surface mounting main switch

/I/SVB
ATEX

Flush mounting

.../E

Flush mounting main switches

/E(A)/SVB

Centre mounting

/EZ

Rear mounting

/Z

Rear mounting main switch

/V/SVB

Service distribution board mounting

/IVS

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

7/4
Rotary switches, switch-disconnectors

System overview Rotary switches


T
Moeller HPL0211-2007/2008 http://catalog.moeller.net

ON-OFF switch T0, T3, T5B, T5

2 1 3

4 10 10

ATEX
5

9 9 8 8

7 7 6
Control switches T0, T3, T5B, T5

ATEX
4 10 10

9 9

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

System overview Rotary switch


http://catalog.moeller.net Moeller HPL0211-2007/2008 Centre mounting (.../EZ) Front IP65 Mounting in fixing hole o 22,3 according to IEC/EN 60947-5-1 "One man mounting" by centre fixing a page 7/21 Surface mounting (.../I...) IP65 2 with an additional terminal Enclosures for metric cable glands to EN 50262 a page 7/21 Surface mounting,main switch (.../I...) 4 IP65 Connection from front a page 7/21 Rear mounting main switch (...V/SVB) 2 Front IP65 To IEC/EN 60 204, VDE 0113 and IEC/EN 60 947-3, for T0... up to 8 and for T3... up to 12 current paths with door interlock in "I" position a page 7/10 Flush mounting (.../E) Front IP65 Mounting and connection from rear Terminals: Crosshead screwdriver Pozidrive Finger- and back-of-hand proof T8 aways with connection bracket a page 7/21 Flush mounting main switch (.../EA/ SVB) Front IP65 To IEC/EN 60204, VDE 0113 and IEC/EN 60947-3, for T0... up to 8 and for T3... up to 12 current paths N and PE terminals a page 7/10 3 3 To IEC/EN 60 204, VDE 0113 and IEC/EN 60 947-3, for T0... up to 8 and for T3... up to 10 current paths Position 0 lockable with 3 padlocks Enclosures for metric cable glands to EN 50262 with an additional terminal a page 7/10 Lockable in the 0 position a page 7/43 Thumb-grip, for use as EmergencyStop device To IEC/EN 60 204-1, VDE 0113 Part 1 Red thumb grip and yellow front plate a page 7/43 Thumb-grip Black thumb-grip with front plate a page 7/43 Coupling drive Including shaft for retrofiiting of switch T0(T3)-.../XZ in rear mounting form Replacement part for T0(T3)/(P1)-.../Z for the conversion of switch T5(B)-.../E to rear mounting switch Replacement part for T5(B)/(P3)-...Z 5 a page 7/49 9 8 4 Main switch (kit) Black rotary handle and locking ring Rear mounting (.../Z) Front IP65 Fixing either by snap-on or screw fixing (T0, T3) for snap fitting to IEC/EN 60 715 top-hat rail Drive coupling in door or cover 7 3 Main switch (mounting kit) for use as 6 Emergency-Stop device To IEC/EN 60204-1, VDE 0113 Part 1 With red rotary handle and yellow lokking ring Lockable in the 0 position a page 7/43 Service distribution board mounting 1 (/IVS) Front IP30 for snap fitting to IEC/EN 60 715 top-hat rail Flush mounting in service distribution board up to 3 height units (45 mm mounting depth) in control panel up to 11 height units a page 7/21

7/5
Rotary switches, switch-disconnectors

10

ATEX
a page 7/43 Safety switch (.../I...) IP65

with an additional terminal with cover safety in 0 position Position 0 lockable with 3 padlocks Enclosures for metric cable glands to EN 50262 Label "Safety switch", colour: orange a page 7/30

ATEX
a page 7/43

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

7/6
Rotary switches, switch-disconnectors

System overview Switch-disconnectors


P
Moeller HPL0211-2007/2008 http://catalog.moeller.net

ON-OFF switches P1, P3

4 4 1

11

2 5 3

ATEX
6

11 10 9

ON OFF switches P5

3 4 2 12 4 13 12

13 4 4

7 8 8 10

10

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

System overview Switch-disconnectors


http://catalog.moeller.net Moeller HPL0211-2007/2008 Flush mounting main switch (.../EA/SVB) Front IP65 To IEC/EN 60204, VDE 0113 and IEC/ EN 60 947-3 N and PE terminals Position 0 lockable with 3 padlocks 2 modules can be retrofitted a page 7/10 Centre mounting (.../EZ) Front IP65 Mounting in fixing hole o 22,3 according to IEC/EN 60 947-5-1 "One man mounting" by centre fixing a page 7/21 for snap fitting to EN 50022 top-hat rail Drive coupling in door or cover Connection from front 2 modules can be retrofitted a page 7/21 Rear mounting main switch (...V/SVB) Front IP65 To IEC/EN 60204, VDE 0113 and IEC/ EN 60 947-3 with door interlock in "I" position Maintenance key for commissioning or faultfinding Position 0 lockable with 3 padlocks 2 modules can be retrofitted a page 7/10 Flush mounting (.../E) Front IP65 Mounting and connection from rear Terminals: Crosshead screwdriver Pozidrive Finger- and back-of-hand proof 2 modules can be retrofitted a page 7/21 3 Surface mounting,main switch (.../I...) IP65 with an additional terminal To IEC/EN 60204, VDE 0113 and IEC/ EN 60947-3 0 position with 3 padlocks Lockable Additional modules can be retrofitted: P1: + 1, P3: + 2 Enclosures for metric cable glands to EN 50262 a page 7/10 5 2 Add-on modules 4 Switchable N conductor (early operation N/O contact) Auxiliary contacts Fingerproof Auxiliary contact, N/O contact: always switched as load-shedding contact (late operation on, early operation off) a page 7/48 Surface mounting (.../I...) IP65 with an additional terminal Additional modules can be retrofitted P1: + 1, P3: + 2 Enclosures for metric cable glands to EN 50262 a page 7/21 5 Main switch (mounting kit) for use as Emergency-Stop device To IEC/EN 60204-1, VDE 0113 Part 1 With red rotary handle and yellow lokking ring Lockable in the 0 position a page 7/43 Main switch (kit) Black rotary handle and locking ring Lockable in the 0 position a page 7/43 Thumb-grip, for use as Emergency-Stop device To IEC/EN 60 204-1, VDE 0113 Part 1 Red thumb-grip and yellow front plate a page 7/43 Thumb-grip Black thumb-grip with front plate a page 7/43 Coupling drive Including shaft for the retrofitting of switch T0(T3)-.../XZ to rear mounting, replacement part for T0(T3)/ (P1)-.../Z for the conversion of T5(B)-.../E to rear mounting switch, replacement part for T5(B)/ (P3)-...Z a page 7/49 Protective conductor terminal Flush mounting, right Service distribution board mounting, left 12 9 8 7 3 3 Safety switch (.../I...-SI) IP65 with an additional terminal with cover safety in 0 position 0 position with 3 padlocks Lockable Label "Safety switch", colour: orange Enclosures for metric cable glands to EN 50262 a page 7/30

7/7
Rotary switches, switch-disconnectors

P
6

Service distribution board mounting (/ 1 IVS) Front IP30 Fitting dimensions according to DIN 43880 for snap fitting to EN 50 022 top-hat rail Space requirement P1, 3 pole: 3 PLE P3, 3 pole: 4 space units P3-,,,/IVS lockable with padlock in "0" position a page 7/21 Rear mounting (.../Z) Front IP65 Fixing either by snap-on or screw fixing 2

ATEX
a page 7/43

10

11

ATEX
a page 7/43

Neutral terminal Flush mounting, left Service distribution board mounting, right a page 7/48

13

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

7/8
Rotary switches, switch-disconnectors

Description Key to part numbers, modular system


T0, T3, T5, T5B
Moeller HPL0211-2007/2008 The switch chamber (contact unit = BE) contains 1 or 2 contacts In our catalogue T Rotary Switches" are over 800 standard circuits (Please order under K115D/F/GB. Article number 077643). On the following pages a selection of oue standard circuits. http://catalog.moeller.net T rotary switches and P switch-disconnectors are manufactured without PCB, CFC, asbestos and silicon. The contacts are free from cadmium. The CI-K... insulated enclosures are silicon and halogen free.

Rotary switches can be used for many switching and control applications. For example as ON-OFF switches, main switches, main/control switches, instrument switches. The switch consists of a hand actuator, the switch unit and the mounting accessories Rotary switches T0 and T3 Key to type references

T......... ... - ............................- .................. ... ../ . . . . . . . . . . . . . . . . . . . . Switch size T0 or T3 Number of contact chambers = contact units (BE) Contact sequence number Mounting form a Page 7/2

Using the modular system to convert the mounting form

T0(3).../E

EZ-T0

V/EA/SVB-T0

T0(3).../XZ

IVS-T0

CI-K1-T0 CI-K2-T3

DE-T0

V/EA/SVB-T0 T0-1-(T3-1-).../EA/SVB . . . T0-4-(T3-6-).../EA/SVB T0.../IVS1) T0(3).../Z1)

T0(3).../EZ

T0-.../I1 T3-.../I2

T0-1-(T3-1-).../V/SVB . . . T0-4-(T3-6-).../V/SVB

TB5 Rotary switches Key to type references T......... ... - ............................- .................. ... ../ . . . . . . . . . . . . . . . . . . . . Switch size T5(B) Number of contact chambers = contact units (BE) Contact sequence number Mounting form a Page 7/2

Using the modular system to convert the mounting form T5(B)

T5(B)...E

V/EA/SVB-T5

DE-P3

CI-K4-T5B CI-K5-T5

V/EA/SVB-T5 T5(B).../Z

SVB-P3

T5(B).../EA/SVB

T5B-.../I4 T5-.../I5

T5(B).../V/SVB

T5B-.../I4/SVB T5-.../I5/SVB

Note

1)

including shaft

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

Ordering Key to part numbers, modular system


http://catalog.moeller.net P1 and P3 Switch-disconnectors Key to type references P. . . . . . . . . . . . - . . . . . . . . . . . . . . . . . . . . . . . . . . . . / . . . . . . . . . . . . . . . . . . . . - . . . . . . . . . . . . . . . . . . / . . . . . . . . . . . . . . . . . . Switch sizes Rated uninterrupted current P1 or P3 Add-on functions due to modular system Mounting form a Page 7/2 Part no. suffix (if required) Accessories from a Page 7/47 Moeller HPL0211-2007/2008

7/9
Rotary switches, switch-disconnectors

P1, P3, TM

N-P...E or N-P...Z

HI 11-P1/P3E or HI 11-P1/P3Z

H-P...

UV-P...

3-pole basic unit .../E or .../Z

Switched neutral Can be fitted left or right (for P1.../I: left only)

Auxiliary contact Can be fitted left or right (for P1.../I: left only)

Terminal shroud can be fitted at top or bottom

N + PE terminals, also as cover interlock on .../Z-switches.

Mini rotary switches TM The mini rotary switch TM is a particulary small switch with a small space requirement. It is ideally suited for small voltages and currents such as electronic controls. For greater safety the contacts are gold plated.

TM switches have continuous terminal markings starting with 1. Selection pages from a page 7/54

Key to type references TM-. . . . . . . . . . . . . . . . . . . . . . . . . - . . . . . . . . . . . . . . . . . . . . . . . / . . . . . . . . . . . . . . . . . . . . + . . . . . . . . . . . . . . . . . . Number of contact chambers = contact units (BE) Contact sequence number Mounting form a Page 7/2 Accessories a Page 7/59

Circuit representation
Front plate inscription
START 2 0 1 START

(see also ordering example in the electronic catalogue)

Bridge Connection designation


1 2 3 4 5 6 7 8

Switch from 0 to 1 contact 1 2 open, contact 3 4 open, contact 5 6 open, contact 7 8 closed

Switch from 1 to START with automatic return to 1 contact 1 2 open, contact 3 4 closed, contact 5 6 open, contact 7 8 remains closed Switch from 2 to START with automatic return to 2 contact 1 2 open, contact 3 4 open, contact 5 6 closes early, contact 7 8 opens late

Switch from 1 to 0 contact 1 2 open, contact 3 4 open, contact 5 6 open, contact 7 8 open

Switch from 0 to 2 contact 1 2 closed, contact 3 4 open, contact 5 6 open, contact 7 8 closed

Switch from 2 to 0 contact 1 2 open, contact 3 4 open, contact 5 6 open, contact 7 8 open

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

7/10
Rotary switches, switch-disconnectors

Ordering Load current switches, main switches, maintenance/repair switches


T, P
Moeller HPL0211-2007/2008 Auxiliary contacts Max. motor rating AC-23A 400/415 V 50-60 Hz N/ P C kW Rated Design uninterrupted current Protection type Part no. Article no. http://catalog.moeller.net Price see price list Std. pack Main conducting paths No. of poles

Contact sequence Front plate no.


ON OFF

N/O

N/O

FS 908

Iu A

Main switches, maintenance switches According to IEC/EN 60204-1, VDE 0113 Part 1; with red rotary handle and yellow locking collar, lockable in 0 position As Emergency-Stop device 1 0 0 6.5 20 Surface mounting IP65 T0-1-8200/I1/SVB 207145 1 0 0 6.5 20 Flush mounting Front IP65 T0-1-8200/EA/SVB 053110 1 0 0 6.5 20 Rear mounting Front IP65 T0-1-8200/V/SVB 057856 1 0 0 13 32 Surface mounting IP65 T3-1-8200/I2/SVB 207200
0 1 1 2

1 off

1 1 1
0 1

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

13 22 22 6.5 6.5 6.5 13 13 13 22 22 30 6.5 6.5 6.5 13 13 13 13 15 15 15 15 37 37 37

32 63 63 20 20 20 32 32 32 63 63 100 20 20 20 25 25 25 25 32 32 32 32 63 63 63

Flush mounting Surface mounting Flush mounting Surface mounting Flush mounting Rear mounting Surface mounting Flush mounting Rear mounting Surface mounting Flush mounting Surface mounting Surface mounting Flush mounting Rear mounting Surface mounting Surface mounting Flush mounting Rear mounting Surface mounting Surface mounting Flush mounting Rear mounting Surface mounting Flush mounting Rear mounting

Front IP65 IP65 Front IP65 IP65 Front IP65 Front IP65 IP65 Front IP65 Front IP65 IP65 Front IP65 IP65 IP65 Front IP65 Front IP65 IP65

T3-1-8200/EA/SVB 066576 T5B-1-8200/I4/SVB 207240 T5B-1-8200/EA/SVB 094279 T0-1-102/I1/SVB 207143 T0-1-102/EA/SVB 091078 T0-1-102/V/SVB 095824 T3-1-102/I2/SVB 207198 T3-1-102/EA/SVB 014374 T3-1-102/V/SVB 019120 T5B-1-102/I4/SVB 207238 T5B-1-102/EA/SVB 094469 T5-1-102/I5/SVB 207273 T0-2-1/I1/SVB 207147 T0-2-1/EA/SVB 038873 T0-2-1/V/SVB 043619 P1-25/I2H/SVB1) 226900 P1-25/I2/SVB 207293 P1-25/EA/SVB 041097 P1-25/V/SVB 055335 P1-32/I2H/SVB1) 227868 P1-32/I2/SVB 207314 P1-32/EA/SVB 081438 P1-32/V/SVB 095676 P3-63/I4/SVB 207343 P3-63/EA/SVB 031607 P3-63/V/SVB 048218

2
1 2 3 4

2 2 2 2 2 2 2 2

0 1

3
1 2 3 4 5 6

3 3 3 3 3 3 3 3 3 3 3 3 3

Front IP65 Front IP65 IP65

Front IP65 Front IP65 IP65 Front IP65 Front IP65

Notes

1) Enclosures

with hard metric knock-outs

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

Ordering Load current switches, main switches, maintenance/repair switches


http://catalog.moeller.net Contact Main sequence conducting Front plate no. paths No. of poles
ON OFF

7/11
Rotary switches, switch-disconnectors

Moeller HPL0211-2007/2008 Auxiliary contacts Max. motor rating AC-23A 400/415 V 50-60 Hz P kW Rated Design uninterrupted current Protection type Part no. Article no.

T, P
Price see price list Std. pack

FS 908

N/O

N/O

N/ C

Iu A

Main switches, maintenance switches According to IEC/EN 60204-1, VDE 0113 Part 1; with red rotary handle and yellow locking collar, lockable in 0 position As Emergency-Stop device 3 0 0 45 125 Flush mounting Front IP65 P5-125/EA/SVB 280898 3 0 0 45 125 Rear mounting Front IP65 P5-125/V/SVB 280914 3 0 0 50 100 Surface mounting IP65 P3-100/I5/SVB 207373
0 1 1 2 3 4 5 6

1 off

3 3 3 3 3 3 3 3
0 1

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

50 50 55 55 90 90 110 110 6.5 6.5 6.5 13 13 13 13 15 15 15 15 37 37 37 45 45 50 50 50

100 100 160 160 250 250 315 315 20 20 20 25 25 25 25 32 32 32 32 63 63 63 125 125 100 100 100

Flush mounting Rear mounting Flush mounting Rear mounting Flush mounting Rear mounting Flush mounting Rear mounting Surface mounting Flush mounting Rear mounting Surface mounting Surface mounting Flush mounting Rear mounting Surface mounting Surface mounting Flush mounting Rear mounting Surface mounting Flush mounting Rear mounting Flush mounting Rear mounting Surface mounting Flush mounting Rear mounting

Front IP65 Front IP65 Front IP65 Front IP65 Front IP65 Front IP65 Front IP65 Front IP65 IP65 Front IP65 Front IP65 IP65

3+N
1 2 3 4 5 6 7 8

P3-100/EA/SVB 074320 P3-100/V/SVB 088558 P5-160/EA/SVB 280922 P5-160/V/SVB 280928 P5-250/EA/SVB 280936 P5-250/V/SVB 280942 P5-315/EA/SVB 280950 P5-315/V/SVB 280956 T0-2-8900/I1/SVB 207151 T0-2-8900/EA/SVB 207400 T0-2-8900/V/SVB 207405 P1-25/I2H/SVB/N1) 227860 P1-25/I2/SVB/N 207298 P1-25/EA/SVB/N 081587 P1-25/V/SVB/N 086333 P1-32/I2/SVB/N 207319 P1-32/I2H/SVB/N1) 227871 P1-32/EA/SVB/N 091079 P1-32/V/SVB/N 095825 P3-63/I4/SVB/N 207349 P3-63/EA/SVB/N 010398 P3-63/V/SVB/N 015144 P5-125/EA/SVB/N 280910 P5-125/V/SVB/N 280916 P3-100/I5/SVB/N 207379 P3-100/EA/SVB/N 019890 P3-100/V/SVB/N 024636

3+N 3+N

0 1

3+N 3+N 3+N 3+N 3+N 3+N 3+N 3+N 3+N 3+N 3+N 3+N 3+N 3+N 3+N 3+N
1 2 3 4 5 6 N N

Front IP65 Front IP65 IP65

Front IP65 Front IP65 IP65 Front IP65 Front IP65 Front IP65 Front IP65 IP65 Front IP65 Front IP65

Notes

1) Enclosures

with hard metric knock-outs

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

7/12
Rotary switches, switch-disconnectors

Ordering Load current switches, main switches, maintenance/repair switches


T, P
Moeller HPL0211-2007/2008 Main Auxiliary conduct- contacts ing paths No. of poles N/O N/ O Max. motor rating AC-23A 400/415 V 50-60 Hz N P / C kW Rated uninterrupted current Design Protection type Part no. Article no. http://catalog.moeller.net Price see price list Std. pack

Contact sequence Front plate no.


ON OFF

FS 908

Iu A

Main switches, maintenance switches According to IEC/EN 60204-1, VDE 0113 Part 1; with red rotary handle and yellow locking collar, lockable in 0 position As Emergency-Stop device 3+N 0 0 55 160 Flush mounting Front IP65
0 1

3+N 3+N 3+N 3+N 3+N

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

55 90 90 110 110 6.5 6.5 6.5 13 13 13 22 22 22 30 30 30 6.5 6.5 6.5 13 13 13 22 22 22 30 30

160 250 250 315 315 20 20 20 32 32 32 63 63 63 100 100 100 20 20 20 32 32 32 63 63 63 100 100

Rear mounting Flush mounting Rear mounting Flush mounting Rear mounting Surface mounting Flush mounting Rear mounting Surface mounting Flush mounting Rear mounting Surface mounting Flush mounting Rear mounting Surface mounting Flush mounting Rear mounting Surface mounting Flush mounting Rear mounting Surface mounting Flush mounting Rear mounting Surface mounting Flush mounting Rear mounting Surface mounting Flush mounting

Front IP65 Front IP65 Front IP65 Front IP65 Front IP65 IP65 Front IP65 Front IP65 IP65 Front IP65 Front IP65 IP65 Front IP65 Front IP65 IP65 Front IP65 Front IP65 IP65 Front IP65 Front IP65 IP65 Front IP65 Front IP65 IP65 Front IP65 Front IP65 IP65 Front IP65

0 1

6
1 2 3 4 5 6 7 8 9 10 11 12

P5-160/EA/SVB/N 280924 P5-160/V/SVB/N 280930 P5-250/EA/SVB/N 280938 P5-250/V/SVB/N 280944 P5-315/EA/SVB/N 280952 P5-315/V/SVB/N 280958 T0-3-8342/I1/SVB 207159 T0-3-8342/EA/SVB 029382 T0-3-8342/V/SVB 034128 T3-3-8342/I2/SVB 207208 T3-3-8342/EA/SVB 071326 T3-3-8342/V/SVB 076072 T5B-3-8342/I4/SVB 207242 T5B-3-8342/EA/SVB 092308 T5B-3-8342/V/SVB 092300 T5-3-8342/I5/SVB 207279 T5-3-8342/EA/SVB 096383 T5-3-8342/V/SVB 096381 T0-4-8344/I1/SVB 207163 T0-4-8344/EA/SVB 008267 T0-4-8344/V/SVB 014007 T3-4-8344/I2/SVB 207212 T3-4-8344/EA/SVB 008964 T3-4-8344/V/SVB 020598 T5B-4-8344/I4/SVB 207248 T5B-4-8344/EA/SVB 092062 T5B-4-8344/V/SVB 092056 T5-4-8344/I5/SVB1) 207283 T5-4-8344/EA/SVB 095961

1 off

1 2 3 4 5 6 N N

6 6 6 6 6 6 6 6 6 6 6

0 1

8
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

8 8 8 8 8 8 8 8 8 8

Notes

1) Rated

uninterrupted current max. 95 A

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

Ordering Load current switches, main switches, maintenance/repair switches


http://catalog.moeller.net Contact sequence Front plate no.
ON OFF

7/13
Rotary switches, switch-disconnectors

Moeller HPL0211-2007/2008 Auxiliary contacts Max. motor rating Rated uninterrupted current Design Protection type Part no. Article no.

T, P
Price Std. pack see price list

Main conducting paths No. of poles N/O

FS 908

N/O

N/C

AC-23A 400/415 V 50-60 Hz P kW

Iu A

Main switches, maintenance switches According to IEC/EN 60204-1, VDE 0113 Part 1; with red rotary handle and yellow locking collar, lockable in 0 position As Emergency-Stop device 3 1 0 6.5 20 Surface IP65 mounting
0 1 1 2 3 4 5 6 7 8

T0-2-15679/I1/SVB 207149 T0-2-15679/EA/SVB 081588 T0-2-15679/V/SVB 086334 P5-125/EA/SVB/HI10 280899 P5-125/V/SVB/HI10 280915 P5-160/EA/SVB/HI10 280923 P5-160/V/SVB/HI10 280929 P5-250/EA/SVB/HI10 280937 P5-250/V/SVB/HI10 280943 P5-315/EA/SVB/HI10 280951 P5-315/V/SVB/HI10 280957 P1-25/I2/SVB/HI11 207297 P1-25/I2H/SVB/HI111) 226902 P1-25/EA/SVB/HI11 091080 P1-25/V/SVB/HI11 095826 P1-32/I2/SVB/HI11 207318 P1-32/I2H/SVB/HI111) 227870 P1-32/EA/SVB/HI11 072567 P1-32/V/SVB/HI11 015145 P3-63/I4/SVB/HI11 207348 P3-63/EA/SVB/HI11 019891 P3-63/V/SVB/HI11 024637 P3-100/I5/SVB/HI11 207378 P3-100/EA/SVB/HI11 029383 P3-100/V/SVB/HI11 034129

1 off

3 3

1 1

0 0

6.5 6.5

20 20

Flush mounting Rear mounting

Front IP65 Front IP65

0 1

3
1 2 3 4 5 6 13 14

1 1

0 0

45 45

125 125

Flush mounting Rear mounting

Front IP65 Front IP65

3 3

1 1

0 0

55 55

160 160

Flush mounting Rear mounting

Front IP65 Front IP65

3 3

1 1

0 0

90 90

250 250

Flush mounting Rear mounting

Front IP65 Front IP65

3 3

1 1

0 0

110 110

315 315

Flush mounting Rear mounting

Front IP65 Front IP65

0 1

3
1 2 3 4 5 6 13 14 21 22

1 1 1 1

1 1 1 1

13 13 13 13

25 25 25 25

Surface mounting Surface mounting Flush mounting Rear mounting

IP65 IP65 Front IP65 Front IP65

3 3 3

3 3 3 3

1 1 1 1

1 1 1 1

15 15 15 15

32 32 32 32

Surface mounting Surface mounting Flush mounting Rear mounting

IP65 IP65 Front IP65 Front IP65

3 3 3

1 1 1

1 1 1

37 37 37

63 63 63

Surface mounting Flush mounting Rear mounting

IP65 Front IP65 Front IP65

3 3 3

1 1 1

1 1 1

50 50 50

100 100 100

Surface mounting Flush mounting Rear mounting

IP65 Front IP65 Front IP65

Notes

1) Enclosures

with hard metric knock-outs

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

7/14
Rotary switches, switch-disconnectors

Ordering Load current switches, main switches, maintenance/repair switches


T, P
Moeller HPL0211-2007/2008 Main conducting paths No. of poles N/O N/ O Auxiliary contacts Max. motor Rated unin- Design rating terrupted current AC-23A 400/415 V 50-60 Hz N/C P kW Protection type Part no. Article no. http://catalog.moeller.net Price Std. see pack price list

Contact sequence Front plate no.


ON OFF

FS 908

Iu A

Main switches, maintenance switches According to IEC/EN 60204-1, VDE 0113 Part 1; with red rotary handle and yellow locking collar, lockable in 0 position As Emergency-Stop device 3 2 1 6.5 20 Surface mounting IP65
0 1 1 2 3 4 5 6 7 8 9 10 11 12

T0-3-15683/I1/SVB 207157 T0-3-15683/EA/SVB 015571 T0-3-15683/V/SVB 015634 T3-3-15683/I2/SVB 207206 T3-3-15683/EA/SVB 040478 T0-3-15680/I1/SVB 207153 T0-3-15680/EA/SVB 038875 T3-3-15680/I2/SVB 207202 T3-3-15680/EA/SVB 012002 P1-25/EA/SVB/N/HI11 048367 P1-25/V/SVB/N/HI11 053113 P1-32/EA/SVB/N/HI11 057859 P1-32/V/SVB/N/HI11 062605 P3-63/I4/SVB/N/HI11 207350 P3-63/EA/SVB/N/HI11 067351 P3-63/V/SVB/N/HI11 072097 P3-100/I5/SVB/N/HI11 207380 P3-100/EA/SVB/N/HI11 076843 P3-100/V/SVB/N/HI11 081589 T0-3-8901/I1/SVB 231934 T5B-3-8901/I4/SVB 207244 T0-4-15682/I1/SVB 207161 T0-4-15682/EA/SVB 019892 T0-4-15682/V/SVB 024638 T3-4-15682/I2/SVB 207210 T3-4-15682/EA/SVB 054716 T3-4-15682/V/SVB 059462 T5B-4-15682/I4/SVB 207246 T5B-4-15682/EA/SVB 207425 T5B-4-15682/V/SVB 207427

1 off

3 3 3 3

2 2 2 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

6.5 6.5 13 13 6.5 6.5 13 13 13 13 15 15 37 37 37 50 50 50 6.5 22 6.5 6.5 6.5 13 13 13 22 22 22

20 20 32 32 20 20 32 32 25 25 32 32 63 63 63 100 100 100 20 63 20 20 20 32 32 32 63 63 63

Flush mounting Rear mounting Surface mounting Flush mounting Surface mounting Flush mounting Surface mounting Flush mounting Flush mounting Rear mounting Flush mounting Rear mounting Surface mounting Flush mounting Rear mounting Surface mounting Flush mounting Rear mounting Surface mounting Surface mounting Surface mounting Flush mounting Rear mounting Surface mounting Flush mounting Rear mounting Surface mounting Flush mounting Rear mounting

Front IP65 Front IP65 IP65 Front IP65 IP65 Front IP65 IP65 Front IP65 Front IP65 Front IP65 Front IP65 Front IP65 IP65 Front IP65 Front IP65 IP65 Front IP65 Front IP65 IP65

0 1

3+N
1 2 3 4 5 6 7 8 9 10 11 12

3+N 3+N 3+N

0 1

3+N
1 2 3 4 5 6 N N 13 14 21 22

3+N 3+N 3+N 3+N 3+N 3+N 3+N 3+N 3+N

0 1

3+N
1 2 3 4 5 6 7 8 9 10 11 12

3+N 6

0 1

IP65 Front IP65 Front IP65 IP65 Front IP65 Front IP65 IP65 Front IP65 Front IP65

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

6 6 6 6 6 6 6 6

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

Ordering Load current switches, main switches, maintenance/repair switches


http://catalog.moeller.net Contact sequence Front plate no.
ON OFF

7/15
Rotary switches, switch-disconnectors

Moeller HPL0211-2007/2008 Main conducting paths No. of poles N/O N/ O Auxiliary contacts Max. motor rating AC-23A 400/415 V 50-60 Hz N/ P C kW Rated uninterrupted current Design Protection type Part no. Article no.

T, P
Price Std. pack see price list

FS 908

Iu A

Main switches, maintenance switches According to IEC/EN 60204-1, VDE 0113 Part 1; with red rotary handle and yellow locking collar, lockable in 0 position As Emergency-Stop device
0 1

6
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

1 1 1 1 1 1 1

1 1 1 1 1 1 1

30 30 30 55 55 132 132

100 100 100 160 160 315 315

Surface mounting Flush mounting Rear mounting Rear mounting Surface mounting Rear mounting Surface mounting

IP65 Front IP65 Front IP65 Front IP65 IP65 Front IP65 IP65

6 6 6 6 6 6

T5-4-15682/I5/SVB 207281 T5-4-15682/EA/SVB 207413 T5-4-15682/V/SVB 207415 T6-160-6/V/SVB/HI11 200619 T6-160-6/I45/SVB/HI111) 201448 T8-3-8342/V/SVB/HI112) 200620 T8-3-8342/I48/SVB/HI11
2)3)

1 off

201450 Main switches, maintenance switches With black rotary handle and locking collar, lockable in the 0 position Without Emergency-Stop function 1 0 0 6.5
0 1 1 2

20 20 32 20 20 20 32 32 20 20 20 25 25 25 25

Surface mounting Flush mounting Surface mounting Surface mounting Flush mounting Rear mounting Surface mounting Flush mounting Surface mounting Flush mounting Rear mounting Surface mounting Surface mounting Flush mounting Rear mounting

IP65 Front IP65 IP65 IP65 Front IP65 Front IP65 IP65 Front IP65 IP65 Front IP65 Front IP65 IP65 IP65 Front IP65 Front IP65

1 1

0 0 0 0 0 0 0 0 0 0 0 0 0 0

0 0 0 0 0 0 0 0 0 0 0 0 0 0

6.5 13 6.5 6.5 6.5 13 13 6.5 6.5 6.5 13 13 13 13

0 1

2
1 2 3 4

2 2 2 2

T0-1-8200/I1/SVB-SW 207146 T0-1-8200/EA/SVB-SW 055483 T3-1-8200/I2/SVB-SW 207201 T0-1-102/I1/SVB-SW 207144 T0-1-102/EA/SVB-SW 093451 T0-1-102/V/SVB-SW 022330 T3-1-102/I2/SVB-SW 207199 T3-1-102/EA/SVB-SW 016747 T0-2-1/I1/SVB-SW 207148 T0-2-1/EA/SVB-SW 041246 T0-2-1/V/SVB-SW 045992 P1-25/I2/SVB-SW 207294 P1-25/I2H/SVB-SW4) 227861 P1-25/EA/SVB-SW 048365 P1-25/V/SVB-SW 050738

1 off

0 1

3
1 2 3 4 5 6

3 3 3 3 3 3

Notes

1) Enclosures 2) with 3) Rated

without flanges with K95/1N/BR KS4-CI and K150/1/BR: Ingress protection IP64 uninterrupted current 315 A in enclosed version max. 275 A 4) Enclosures with hard metric knock-outs

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

7/16
Rotary switches, switch-disconnectors

Ordering Load current switches, main switches, maintenance/repair switches


T, P
Moeller HPL0211-2007/2008 Auxiliary contacts Max. motor Rated rating uninterrupted current AC-23A 400/415 V 50-60 Hz N P /C kW Design Protection type Part no. Article no. http://catalog.moeller.net Price see price list Std. pack Main conducting paths No. of poles

Contact sequence Front plate no.


ON OFF

FS 908

N/O

N/O

Iu A

Main switches, maintenance switches With black rotary handle and locking collar, lockable in the 0 position Without Emergency-Stop function 3
1 2 3 4 5 6

0 1

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

15 15 15 15 37 37 37 50 50 50 45 45 55 55 90 90 110 6.5 6.5 6.5 13 13 13 13 15 15 15 15 37 37 37

32 32 32 32 63 63 63 100 100 100 125 125 160 160 250 250 315 20 20 20 25 25 25 25 32 32 32 32 63 63 63

3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3

0 1

3+N
1 2 3 4 5 6 7 8

3+N 3+N

0 1

3+N
1 2 3 4 5 6 N N

3+N 3+N 3+N 3+N 3+N 3+N 3+N 3+N 3+N 3+N

Surface mounting Surface mounting Flush mounting Rear mounting Surface mounting Flush mounting Rear mounting Surface mounting Flush mounting Rear mounting Flush mounting Rear mounting Flush mounting Rear mounting Flush mounting Rear mounting Flush mounting Surface mounting Flush mounting Rear mounting Surface mounting Surface mounting Flush mounting Rear mounting Surface mounting Surface mounting Flush mounting Rear mounting Surface mounting Flush mounting Rear mounting

IP65 IP65 Front IP65 Front IP65 IP65 Front IP65 Front IP65 IP65 Front IP65 Front IP65 Front IP65 Front IP65 Front IP65 Front IP65 Front IP65 Front IP65 Front IP65 IP65 Front IP65 Front IP65 IP65 IP65 Front IP65 Front IP65 IP65 IP65 Front IP65 Front IP65 IP65 Front IP65 Front IP65

P1-32/I2/SVB-SW 207315 P1-32/I2H/SVB-SW1) 227872 P1-32/EA/SVB-SW 053111 P1-32/V/SVB-SW 055484 P3-63/I4/SVB-SW 207344 P3-63/EA/SVB-SW 057857 P3-63/V/SVB-SW 060230 P3-100/I5/SVB-SW 207374 P3-100/EA/SVB-SW 062603 P3-100/V/SVB-SW 064976 P5-125/EA/SVB-SW 280911 P5-125/V/SVB-SW 280917 P5-160/EA/SVB-SW 280925 P5-160/V/SVB-SW 280931 P5-250/EA/SVB-SW 280939 P5-250/V/SVB-SW 280945 P5-315/EA/SVB-SW 280953 T0-2-8900/I1/SVB-SW 207152 T0-2-8900/EA/SVB-SW 207401 T0-2-8900/V/SVB-SW 207406 P1-25/I2/SVB-SW/N 207296 P1-25/I2H/SVB-SW/N1) 227863 P1-25/EA/SVB-SW/N 083960 P1-25/V/SVB-SW/N 088706 P1-32/I2/SVB-SW/N 207317 P1-32/I2H/SVB-SW/N1) 227874 P1-32/EA/SVB-SW/N 093452 P1-32/V/SVB-SW/N 098198 P3-63/I4/SVB-SW/N 207346 P3-63/EA/SVB-SW/N 012771 P3-63/V/SVB-SW/N 017517

1 off

Notes

1) Enclosures

with hard metric knock-outs

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

Ordering Load current switches, main switches, maintenance/repair switches


http://catalog.moeller.net Contact sequence Front plate no.
ON OFF

7/17
Rotary switches, switch-disconnectors

Moeller HPL0211-2007/2008 Main Auxiliary conduct- contacts ing paths No. of poles N/O N/ O N/ C Max. motor rating AC-23A 400/415 V 50-60 Hz P kW Rated uninterrupted current Design Protection type Part no. Article no.

T, P
Price see price list Std. pack

FS 908

Iu A

Main switches, maintenance switches With black rotary handle and locking collar, lockable in the 0 position Without Emergency-Stop function 3+N 0 0 50 100
0 1 1 2 3 4 5 6 N N

Surface mounting Flush mounting Rear mounting Flush mounting Rear mounting Flush mounting Rear mounting Flush mounting Rear mounting Flush mounting Surface mounting Flush mounting Rear mounting Surface mounting Flush mounting Rear mounting Surface mounting Flush mounting Rear mounting Surface mounting Flush mounting Rear mounting Surface mounting Flush mounting Surface mounting Flush mounting Rear mounting Surface mounting Flush mounting Surface mounting

IP65 Front IP65 Front IP65 Front IP65 Front IP65 Front IP65 Front IP65 Front IP65 Front IP65 Front IP65 IP65 Front IP65 Front IP65 IP65 Front IP65 Front IP65 IP65 Front IP65 Front IP65 IP65 Front IP65 Front IP65 IP65 Front IP65 IP65 Front IP65 Front IP65 IP65 Front IP65 IP65

3+N 3+N 3+N 3+N 3+N 3+N 3+N 3+N 3+N

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

50 50 45 45 55 55 90 90 110 6.5 6.5 6.5 13 13 13 22 22 22 30 30 30 6.5 6.5 13 13 13 22 22 30

100 100 125 125 160 160 250 250 315 20 20 20 32 32 32 63 63 63 100 100 100 20 20 32 32 32 63 63 100

0 1

6
1 2 3 4 5 6 7 8 9 10 11 12

6 6 6 6 6 6 6 6 6 6 6

0 1

8
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

8 8 8 8 8 8 8

P3-100/I5/SVB-SW/N 207376 P3-100/EA/SVB-SW/N 022263 P3-100/V/SVB-SW/N 027009 P5-125/EA/SVB-SW/N 280913 P5-125/V/SVB-SW/N 280919 P5-160/EA/SVB-SW/N 280927 P5-160/V/SVB-SW/N 280933 P5-250/EA/SVB-SW/N 280941 P5-250/V/SVB-SW/N 280947 P5-315/EA/SVB-SW/N 280955 T0-3-8342/I1/SVB-SW 207160 T0-3-8342/EA/SVB-SW 031755 T0-3-8342/V/SVB-SW 036501 T3-3-8342/I2/SVB-SW 207209 T3-3-8342/EA/SVB-SW 073699 T3-3-8342/V/SVB-SW 078445 T5B-3-8342/I4/SVB-SW 207243 T5B-3-8342/EA/SVB-SW 092307 T5B-3-8342/V/SVB-SW 092299 T5-3-8342/I5/SVB-SW 207280 T5-3-8342/EA/SVB-SW 096382 T5-3-8342/V/SVB-SW 096380 T0-4-8344/I1/SVB-SW 207164 T0-4-8344/EA/SVB-SW 008268 T3-4-8344/I2/SVB-SW 207213 T3-4-8344/EA/SVB-SW 008965 T3-4-8344/V/SVB-SW 008967 T5B-4-8344/I4/SVB-SW 207249 T5B-4-8344/EA/SVB-SW 092061 T5-4-8344/I5/SVB-SW1) 207284

1 off

Notes

1) Rated

uninterrupted current max. 95 A

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

7/18
Rotary switches, switch-disconnectors

Ordering Load current switches, main switches, maintenance/repair switches


T, P
Moeller HPL0211-2007/2008 Max. motor Rated rating uninterrupted current AC-23A 400/415 V 50-60 Hz N P Iu / C kW A Design Protection type Part no. Article no. http://catalog.moeller.net Price see price list Std. pack Main Auxiliary conduct- contacts ing paths No. of poles N/O

Contact sequence Front plate no.


ON OFF

FS 908

N/ O

Main switches, maintenance switches With black rotary handle and locking collar, lockable in the 0 position Without Emergency-Stop function 3 1 0 6.5 20
0 1 1 2 3 4 5 6 7 8

Surface mounting Flush mounting Rear mounting Flush mounting Rear mounting Flush mounting Rear mounting Flush mounting Rear mounting Rear mounting Surface mounting Surface mounting Flush mounting Rear mounting Surface mounting Surface mounting Flush mounting Rear mounting Surface mounting Flush mounting Rear mounting Surface mounting Flush mounting Rear mounting Surface mounting Flush mounting Surface mounting Flush mounting Surface mounting Flush mounting Surface mounting

IP65 Front IP65 Front IP65 Front IP65 Front IP65 Front IP65 Front IP65 Front IP65 Front IP65 Front IP65 IP65 IP65 Front IP65 Front IP65 IP65 IP65 Front IP65 Front IP65 IP65 Front IP65 Front IP65 IP65 Front IP65 Front IP65 IP65 Front IP65 IP65 Front IP65 IP65 Front IP65 IP65

3 3 3 3 3 3 3 3 3

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 2 2 1 1 1

0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

6.5 6.5 45 45 55 55 90 90 110 13 13 13 13 15 15 15 15 37 37 37 50 50 50 6.5 6.5 13 13 6.5 6.5 13

20 20 125 125 160 160 250 250 315 25 25 25 25 32 32 32 32 63 63 63 100 100 100 20 20 32 32 20 20 32

0 1

3
1 2 3 4 5 6 13 14 21 22

3 3 3 3 3 3 3 3 3 3 3 3 3

0 1

3
1 2 3 4 5 6 7 8 9 10 11 12

3 3 3

0 1

3+N
1 2 3 4 5 6 7 8 9 10 11 12

3+N 3+N

T0-2-15679/I1/SVB-SW 207150 T0-2-15679/EA/SVB-SW 083961 T0-2-15679/V/SVB-SW 088707 P5-125/EA/SVB-SW/HI10 280912 P5-125/V/SVB-SW/HI10 280918 P5-160/EA/SVB-SW/HI10 280926 P5-160/V/SVB-SW/HI10 280932 P5-250/EA/SVB-SW/HI10 280940 P5-250/V/SVB-SW/HI10 280946 P5-315/V/SVB-SW/HI10 280960 P1-25/I2/SVB-SW/HI11 207295 P1-25/I2H/SVB-SW/HI111) 227862 P1-25/EA/SVB-SW/HI11 070194 P1-25/V/SVB-SW/HI11 098199 P1-32/I2/SVB-SW/HI11 207316 P1-32/I2H/SVB-SW/HI111) 227873 P1-32/EA/SVB-SW/HI11 012772 P1-32/V/SVB-SW/HI11 017518 P3-63/I4/SVB-SW/HI11 207345 P3-63/EA/SVB-SW/HI11 022264 P3-63/V/SVB-SW/HI11 027010 P3-100/I5/SVB-SW/HI11 207375 P3-100/EA/SVB-SW/HI11 031756 P3-100/V/SVB-SW/HI11 036502 T0-3-15683/I1/SVB-SW 207158 T0-3-15683/EA/SVB-SW 015600 T3-3-15683/I2/SVB-SW 207207 T3-3-15683/EA/SVB-SW 042851 T0-3-15680/I1/SVB-SW 207154 T0-3-15680/EA/SVB-SW 041248 T3-3-15680/I2/SVB-SW 207203

1 off

Notes

1) Enclosures

with hard metric knock-outs

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

Ordering Load current switches, main switches, maintenance/repair switches


http://catalog.moeller.net Contact sequence Front plate no.
ON OFF

7/19
Rotary switches, switch-disconnectors

Moeller HPL0211-2007/2008 Main Auxiliary conduct- contacts ing paths No. of poles N/O N/ O Max. motor Rated rating uninterrupted current AC-23A 400/415 V 50-60 Hz N/ P Iu C kW A Design Protection type Part no. Article no.

T, P
Price see price list Std. pack

FS 908

Main switches, maintenance switches With black rotary handle and locking collar, lockable in the 0 position Without Emergency-Stop function 3+N 1 1 13 25
0 1

Flush mounting Flush mounting Rear mounting Surface mounting Flush mounting Rear mounting Surface mounting Flush mounting Rear mounting Flush mounting Surface mounting Surface mounting Flush mounting Surface mounting Surface mounting Flush mounting Rear mounting Surface mounting Flush mounting Rear mounting Surface mounting Flush mounting Rear mounting Surface mounting Flush mounting Rear mounting Surface mounting Rear mounting Surface mounting Rear mounting

Front IP65 Front IP65 Front IP65 IP65 Front IP65 Front IP65 IP65 Front IP65 Front IP65 Front IP65 IP65 IP65 Front IP65 IP65 IP65 Front IP65 Front IP65 IP65 Front IP65 Front IP65 IP65 Front IP65 Front IP65 IP65 Front IP65 Front IP65 IP65 Front IP65 IP65 Front IP65

3+N 3+N 3+N 3+N 3+N 3+N 3+N 3+N

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

15 15 37 37 37 50 50 50 6.5 13 22 22 30 6.5 6.5 6.5 13 13 13 22 22 22 30 30 30 55 55 132 132

32 32 63 63 63 100 100 100 20 32 63 63 100 20 20 20 32 32 32 63 63 63 100 100 100 160 160 315 315

0 1

3+N 3+N 3+N 3+N 3+N


1 2 3 4 5 6 7 8 9 10 11 12

0 1

6
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

6 6 6 6 6 6 6 6 6 6 6 6 6 6 6

P1-25/EA/SVB-SW/N/HI11 050740 P1-32/EA/SVB-SW/N/HI11 060232 P1-32/V/SVB-SW/N/HI11 064978 P3-63/I4/SVB-SW/N/HI11 207347 P3-63/EA/SVB-SW/N/HI11 069724 P3-63/V/SVB-SW/N/HI11 074470 P3-100/I5/SVB-SW/N/HI11 207377 P3-100/EA/SVB-SW/N/HI11 079216 P3-100/V/SVB-SW/N/HI11 083962 T0-3-8901/EA/SVB-SW 231933 T3-3-8901/I2/SVB-SW 218988 T5B-3-8901/I4/SVB-SW 207245 T5B-3-8901/EA/SVB-SW 207421 T5-3-8901/I5/SVB-SW 207278 T0-4-15682/I1/SVB-SW 207162 T0-4-15682/EA/SVB-SW 022265 T0-4-15682/V/SVB-SW 027011 T3-4-15682/I2/SVB-SW 207211 T3-4-15682/EA/SVB-SW 057089 T3-4-15682/V/SVB-SW 061835 T5B-4-15682/I4/SVB-SW 207247 T5B-4-15682/EA/SVB-SW 207426 T5B-4-15682/V/SVB-SW 207428 T5-4-15682/I5/SVB-SW 207282 T5-4-15682/EA/SVB-SW 207414 T5-4-15682/V/SVB-SW 207416 T6-160-6/I45/SVB-SW/HI11
1)

1 off

1 2 3 4 5 6 7 8 9 10 11 12

201447 T6-160-6/V/SVB-SW/HI11 200127 T8-3-8342/I48/SVB-SW/ HI112)3) 201449 T8-3-8342/V/SVB-SW/HI113) 200128

Notes

1) Enclosures 2) with

without flanges with K95/1N/BR KS4-CI and K150/1/BR: IP64 3) Rated uninterrupted current 315 A in enclosed version max. 275 A

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

7/20
Rotary switches, switch-disconnectors

Ordering Load current switches, main switches, maintenance/repair switches


T, P
Moeller HPL0211-2007/2008 Auxiliary contacts Max. motor rating Rated uninterrupted current Iu A Design Protection type Part no. Article no. http://catalog.moeller.net Price see price list Std. pack Main conducting paths No. of poles

Contact sequence Front plate no.


ON OFF

AC-23A

FS 908

N/O

N/O

N/C

400/415 V 50-60 Hz P kW

On-Off switches As Emergency-Stop device According to IEC/EN60204-1, VDE 113 Part 1 with red thumb grip and yellow front plate 1 0 0
0 1 1 2

6.5 6.5

20 20

Flush mounting Distribution board mounting Surface mounting Flush mounting Flush mounting Surface mounting Flush mounting Distribution board mounting Surface mounting Flush mounting Distribution board mounting Flush mounting Distribution board mounting Flush mounting Distribution board mounting Surface mounting Flush mounting Distribution board mounting Flush mounting

Front IP65 Front IP30

T0-1-8200/E-RT 009474 T0-1-8200/IVS-RT 081956

1 off

0 1

2
1 2 3 4

0 0 0 0 0 0

0 0 0 0 0 0

6.5 6.5 22 6.5 6.5 6.5

20 20 32 20 20 20

IP65 Front IP65 Front IP65 IP65 Front IP65 Front IP30

T0-1-102/I1-RT 207062 T0-1-102/E-RT 009046 T3-1-102/E-RT 016318 T0-2-1/I1-RT 207082 T0-2-1/E-RT 011082 T0-2-1/IVS-RT 084329

2 2

0 1

3
1 2 3 4 5 6

3 3

3 3 3

0 0 0

0 0 0

13 13 13

25 25 25

IP65 Front IP65 Front IP30

P1-25/I2-RT 207300 P1-25/E-RT 002388 P1-25/IVS-RT 013140

3 3

0 0

0 0

15 15

32 32

Front IP65 Front IP30

P1-32/E-RT 003197 P1-32/IVS-RT 022632

3 3

0 0

0 0

37 37

63 63

Front IP65 Front IP30

P3-63/E-RT 005743 P3-63/IVS-RT 045845

3 3 3

0 0 0

0 0 0

50 50 50

100 100 100

IP65 Front IP65 Front IP30

P3-100/I5-RT 207382 P3-100/E-RT 007189 P3-100/IVS-RT 086185

0 1

3+N
1 2 3 4 5 6 7 8

6.5

20

Front IP65

T0-2-8900/E-RT 207399

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

Ordering Load current switches, ON/OFF switches


http://catalog.moeller.net Contact sequence Front plate no.
ON OFF

7/21
Rotary switches, switch-disconnectors

Moeller HPL0211-2007/2008 Auxiliary contacts Max. motor rating AC-23A 400/415 V 50-60 Hz P kW Rated uninterrupted current Design Protection type Part no. Article no.

T, P
Std. pack

Main conducting paths No. of poles N/O

FS 908

N/ O

N/ C

Iu A

0 1

On-Off switches with black thumb grip and front plate Without auxiliary contacts 1 0
1 2

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

6.5 6.5 6.5 6.5 6.5 13 13 13 22 6.5 6.5 6.5 6.5 6.5 22 22 22 22 22 6.5 6.5 6.5 6.5 6.5 13 13 13 13 13 13

20 20 20 20 20 32 32 32 63 20 20 20 20 20 32 32 32 32 63 20 20 20 20 20 25 25 25 25 25 25

Surface mounting Flush mounting Distribution board mounting Centre mounting Rear mounting Flush mounting Surface mounting Centre mounting Flush mounting Surface mounting Flush mounting Distribution board mounting Centre mounting Rear mounting Surface mounting Flush mounting Centre mounting Rear mounting Flush mounting Surface mounting Flush mounting Distribution board mounting Centre mounting Rear mounting Surface mounting Surface mounting Flush mounting Distribution board mounting Centre mounting Rear mounting

IP65 Front IP65 Front IP30 Front IP65 Front IP65 Front IP65 IP65 Front IP65 Front IP65 IP65 Front IP65 Front IP30 Front IP65 Front IP65 IP65 Front IP65 Front IP65 Front IP65 Front IP65 IP65 Front IP65 Front IP30 Front IP65 Front IP65 IP65 IP65 Front IP65 Front IP30 Front IP65 Front IP65

1 1 1 1 1 1 1 1

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

T0-1-8200/I1 207074 T0-1-8200/E 067352 T0-1-8200/IVS 074471 T0-1-8200/EZ 069725 T0-1-8200/Z 076844 T3-1-8200/E 064208 T3-1-8200/I2 207167 T3-1-8200/EZ 066581 T5B-1-8200/E 094281 T0-1-102/I1 207061 T0-1-102/E 088709 T0-1-102/IVS 015147 T0-1-102/EZ 091082 T0-1-102/Z 095828 T3-1-102/I2 207165 T3-1-102/E 076073 T3-1-102/EZ 078446 T3-1-102/Z 083192 T5B-1-102/E 094471 T0-2-1/I1 207081 T0-2-1/E 024639 T0-2-1/IVS 031758 T0-2-1/EZ 027012 T0-2-1/Z 036504 P1-25/I2 207299 P1-25/I2H1) 226898 P1-25/E 038724 P1-25/IVS 052962 P1-25/EZ 041250 P1-25/Z 057708

1 off

0 1

2 2 2 2 2 2 2 2 2 2
1 2 3 4

0 1

3
1 2 3 4 5 6

3 3 3 3 3 3 3 3 3 3

Notes

1) Enclosures

with hard metric knock-outs

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

7/22
Rotary switches, switch-disconnectors

Ordering Load current switches, ON/OFF switches


T, P
Moeller HPL0211-2007/2008 Auxiliary contacts Max. motor rating AC-23A N/ O 400/415 V N 50-60 Hz / P C kW Rated uninterrupted current Design Protection type Part no. Article no. http://catalog.moeller.net Std. pack Main conducting paths No. of poles N/O

Contact sequence Front plate no.


ON OFF

FS 908

Iu A

On-Off switches with black thumb grip and front plate Without auxiliary contacts 3 0
0 1 1 2 3 4 5 6

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

15 15 15 15 15 15 37 37 37 37 45 45 50 50 50 50 55 55 90 90 110 110 6.5 6.5 6.5 6.5 6.5

32 32 32 32 32 32 63 63 63 63 125 125 100 100 100 100 160 160 250 250 315 315 20 20 20 20 20

Surface mounting Surface mounting Flush mounting Distribution board mounting Centre mounting Rear mounting Surface mounting Flush mounting Distribution board mounting Rear mounting Flush mounting Rear mounting Surface mounting Flush mounting Distribution board mounting Rear mounting Flush mounting Rear mounting Flush mounting Rear mounting Flush mounting Rear mounting Surface mounting Flush mounting Distribution board mounting Centre mounting Rear mounting

IP65 IP65 Front IP65 Front IP30 Front IP65 Front IP65 IP65 Front IP65 Front IP30 Front IP65 Front IP65 Front IP65 IP65 Front IP65 Front IP30 Front IP65 Front IP65 Front IP65 Front IP65 Front IP65 Front IP65 Front IP65 IP65 Front IP65 Front IP30 Front IP65 Front IP65

3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

P1-32/I2 207320 P1-32/I2H1) 227866 P1-32/E 079065 P1-32/IVS 093303 P1-32/EZ 048369 P1-32/Z 098049 P3-63/I4 207356 P3-63/E 026861 P3-63/IVS 041099 P3-63/Z 050591 P5-125/E 280897 P5-125/Z 280920 P3-100/I5 207381 P3-100/E 067201 P3-100/IVS 081439 P3-100/Z 090931 P5-160/E 280921 P5-160/Z 280934 P5-250/E 280935 P5-250/Z 280948 P5-315/E 280949 P5-315/Z 280962 T0-2-8900/I1 207109 T0-2-8900/E 207398 T0-2-8900/ IVS 207403 T0-2-8900/EZ 207402 T0-2-8900/Z 207407

1off

0 1

3+N
1 2 3 4 5 6 7 8

3+N 3+N 3+N 3+N

Notes

1) Enclosures

with hard metric knock-outs

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

Ordering Load current switches, ON/OFF switches


http://catalog.moeller.net Contact sequence Front plate no.
ON OFF

7/23
Rotary switches, switch-disconnectors

Moeller HPL0211-2007/2008 Auxiliary contacts Max. motor rating AC-23A 400/415 V N/C 50-60 Hz P kW Rated uninterrupted current Design Protection type Part no. Article no.

T, P
Price see price list Std. pack

Main conducting paths No. of poles

FS 908

N/O

N/O

Iu A

On-Off switches with black thumb grip and front plate Without auxiliary contacts 3+N 0
0 1 1 2 3 4 5 6 N N

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

13 13 13 13 13 13 15 15 15 15 15 15 37 37 37 37 50 50 50 50 6.5 6.5 6.5 6.5 6.5 22 22 22 22

25 25 25 25 25 25 32 32 32 32 32 32 63 63 63 63 100 100 100 100 20 20 20 20 20 32 32 63 63

Surface mounting Surface mounting Flush mounting Distribution board mounting Centre mounting Rear mounting Surface mounting Surface mounting Flush mounting Distribution board mounting Centre mounting Rear mounting Surface mounting Flush mounting Distribution board mounting Rear mounting Surface mounting Flush mounting Distribution board mounting Rear mounting Surface mounting Flush mounting Distribution board mounting Centre mounting Rear mounting Surface mounting Flush mounting Surface mounting Flush mounting

IP65 IP65 Front IP65 Front IP30 Front IP65 Front IP65 IP65 IP65 Front IP65 Front IP30 Front IP65 Front IP65 IP65 Front IP65 Front IP30 Front IP65 IP65 Front IP65 Front IP30 Front IP65 IP65 Front IP65 Front IP30 Front IP65 Front IP65 IP65 Front IP65 IP65 Front IP65

3+N 3+N 3+N 3+N 3+N 3+N 3+N 3+N 3+N 3+N 3+N 3+N 3+N 3+N 3+N 3+N 3+N 3+N 3+N

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

P1-25/I2/N 207303 P1-25/I2H/N1) 226901 P1-25/E/N 076845 P1-25/IVS/N 083964 P1-25/EZ/N 079218 P1-25/Z/N 088710 P1-32/I2/N 207324 P1-32/I2H/N1) 227869 P1-32/E/N 093456 P1-32/IVS/N 010402 P1-32/EZ/N 095829 P1-32/Z/N 015148 P3-63/I4/N 207360 P3-63/E/N 019894 P3-63/IVS/N 022267 P3-63/Z/N 027013 P3-100/I5/N 207385 P3-100/E/N 031759 P3-100/IVS/N 034132 P3-100/Z/N 038878 T0-3-8342/I1 207131 T0-3-8342/E 043624 T0-3-8342/IVS 050743 T0-3-8342/EZ 045997 T0-3-8342/Z 055489 T3-3-8342/I2 207187 T3-3-8342/E 045225 T5B-3-8342/I4 207226 T5B-3-8342/E 092310

1off

0 1

6
1 2 3 4 5 6 7 8 9 10 11 12

6 6 6 6 6 6 6 6

Notes

1) Enclosures

with hard metric knock-outs

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

7/24
Rotary switches, switch-disconnectors

Ordering Load current switches, ON/OFF switches


T, P
Moeller HPL0211-2007/2008 Main conducting paths No. of poles Auxiliary contacts Max. motor rating Rated uninterrupted current Design Protection type Part no. Article no. http://catalog.moeller.net Price see price list Std. pack

Contact sequence Front plate no.


ON OFF

AC-23A

FS 908

N/O

N/O N/C

400/415 V 50-60 Hz P kW

Iu A

On-Off switches with black thumb grip and front plate Without auxiliary contacts 8
0 1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

0 0 0

0 0 0

6.5 6.5 6.5

20 20 20

Surface mounting Flush mounting Distribution board mounting Centre mounting

IP65 Front IP65 Front IP30

T0-4-8344/I1 207139 T0-4-8344/E 014000 T0-4-8344/IVS 014006 T0-4-8344/EZ 014002 T5B-4-8344/I4 207233 T0-2-15679/I1 207094 T0-2-15679/E 029387 T0-2-15679/IVS 036506 T0-2-15679/Z 041252 T0-3-8901/I1 231941 T0-3-8901/E 231938 P1-25/I2H/HI111) 226899 P1-32/I2H/HI111) 227867 T0-3-15683/I1 207118 T0-4-15682/I1 207135 T0-4-15682/E 010405 T3-4-15682/I2 207190 T3-4-15682/E 023869 T5B-4-15682/I4 207229 T5B-4-15682/E 207424 T5B-4-15682/Z 207429 T5-4-15682/I5 207269

1 off

8 8

6.5

20

Front IP65

8 With auxiliary contacts


0 1

22

63

Surface mounting

IP65

3
1 2 3 4 5 6 7 8

1 1 1

0 0 0

6.5 6.5 6.5

20 20 20

Surface mounting Flush mounting Distribution board mounting Rear mounting

IP65 Front IP65 Front IP30

1 off

3 3

6.5

20

Front IP65

0 1

3
1 2 3 4 5 6 7 8 9 10 11 12

1 1 1 1 2 1 1 1 1 1 1 1

1 1 1 1 1 1 1 1 1 1 1 1

6.5 6.5 13 15 6.5 6.5 6.5 22 22 22 22 22

20 20 25 32 20 20 20 32 32 63 63 63

Surface mounting Flush mounting Surface mounting Surface mounting Surface mounting Surface mounting Flush mounting Surface mounting Flush mounting Surface mounting Flush mounting Rear mounting

IP65 Front IP65 IP65 IP65 IP65 IP65 Front IP65 IP65 Front IP65 IP65 Front IP65 Front IP65

3 3

0 1 1 2 3 4 5 6 13 14 21 22

3 3

0 1 1 2 3 4 5 6 7 8 9 10 11 12

0 1

6
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

6 6 6 6 6 6

6 Notes
1) Enclosures

30

100

Surface mounting

IP65

with hard metric knock-outs

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

Ordering Load current switches, changeover switches


http://catalog.moeller.net Contact sequence Front plate no. Moeller HPL0211-2007/2008 Main conducting paths No. of poles Max. motor rating Rated uninterrupted current Design

7/25
Rotary switches, switch-disconnectors

T0, T3, T5(B), T6, T8


Protection type Part no. Article no. Price see price list Std. pack

N/O

AC-23A 400/415 V 50-60 Hz P

Iu A

kW Changeover switches With black thumb-grip and grey front plate With 0 (Off) position Group switches, mains transfer switches 0 1
2 0 1
1 2

6.5 6.5 6.5

20 20 20

Surface mounting Flush mounting Distribution board mounting Centre mounting

IP65 Front IP65 Front IP30

T0-1-8210/I1 207076 T0-1-8210/E 012742 T0-1-8210/IVS 074440 T0-1-8210/EZ 048337 T3-1-8210/E 054718 T5B-1-8210/I4 207432 T5B-1-8210/E 094261 T5B-1-8210/Z 094258 T0-2-8211/I1 207102 T0-2-8211/E 022234 T0-2-8211/IVS 076813 T0-2-8211/EZ 053083 T3-2-8211/I2 207178 T3-2-8211/E 061837 T3-2-8211/EZ 003075 T3-2-8211/Z 064210 T5B-2-8211/I4 207220 T5B-2-8211/E 093094 T5B-2-8211/Z 093082 T0-3-8212/I1 207123 T0-3-8212/E 029353 T0-3-8212/IVS 079186 T0-3-8212/EZ 057829 T0-3-8212/Z 036473

1 off

1 2 3 4

FS 684

1 1

6.5

20

Front IP65

1 1 1 1
2 0 1
0 1 2

13 22 22 22 6.5 6.5 6.5

32 63 63 63 20 20 20

Flush mounting Surface mounting Flush mounting Rear mounting Surface mounting Flush mounting Distribution board mounting Centre mounting

Front IP65 IP65 Front IP65 Front IP65 IP65 Front IP65 Front IP30

2 2 2

1 2 3 4 5 6 7 8

FS 684

6.5

20

Front IP65

2 2 2

13 13 13

32 32 32

Surface mounting Flush mounting Centre mounting

IP65 Front IP65 Front IP65

2 2 2 2
2 0 1
0 1 2

13 22 22 22 6.5 6.5 6.5

32 63 63 63 20 20 20

Rear mounting Surface mounting Flush mounting Rear mounting Surface mounting Flush mounting Distribution board mounting Centre mounting

Front IP65 IP65 Front IP65 Front IP65 IP65 Front IP65 Front IP30

3 3 3

1 2 3 4 5 6 7 8 9 10 11 12

FS 684

6.5

20

Front IP65

6.5

20

Rear mounting

Front IP65

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

7/26
Rotary switches, switch-disconnectors

Ordering Load current switches, changeover switches


T0, T3, T5(B), T6, T8
Moeller HPL0211-2007/2008 Max. motor rating Rated uninterrupted current Design Protection type Part no. Article no. http://catalog.moeller.net Price see price list Std. pack Front plate no. Main conducting paths No. of poles

Contact sequence

AC-23A 400/415 V 50-60 Hz P

N/O

Iu A

kW Changeover switches With black thumb-grip and grey front plate With 0 (Off) position Group switches, mains transfer switches
2 0 1
0 1 2

3 3 3

13 13 13

32 32 32

Surface mounting Flush mounting Centre mounting

IP65 Front IP65 Front IP65

T3-3-8212/I2 207183 T3-3-8212/E 068956 T3-3-8212/EZ 003080 T3-3-8212/Z 071329 T5B-3-8212/I4 207223 T5B-3-8212/E 092386 T5B-3-8212/Z 092383 T5-3-8212/E 096466 T5-3-8212/I5 207266 T5-3-8212/Z 096464 T6-3-8212/E/HI12 214781 T8-3-8212/E/HI12 214782 T0-4-8213/I1 207136 T0-4-8213/E 031726 T0-4-8213/IVS 081559 T0-4-8213/EZ 062575 T0-4-8213/Z 043592 T3-4-8213/I2 207191 T3-4-8213/E 076075 T3-4-8213/Z 078448 T5B-4-8213/I4 207230 T5B-4-8213/E 092112 T5B-4-8213/Z 092109 T5-4-8213/I5 207270 T5-4-8213/E 096014 T5-4-8213/Z 096012

1 off

1 2 3 4 5 6 7 8 9 10 11 12

FS 684

3 3 3 3 3 3 3
1 0 2
0 1 2

13 22 22 22 30 30 30 45 132 6.5 6.5 6.5 6.5

32 63 63 63 100 100 100 125 315 20 20 20 20

Rear mounting Surface mounting Flush mounting Rear mounting Flush mounting Surface mounting Rear mounting Flush mounting Flush mounting Surface mounting Flush mounting Distribution board mounting Centre mounting

Front IP65 IP65 Front IP65 Front IP65 Front IP65 IP65 Front IP65 Front IP65 Front IP65 IP65 Front IP65 Front IP30 Front IP65

3 3

1 2 3 4 5 6 7 8 9 10 11 12 101 102 103 104 105 106

1 0 2

0 1 2

4 4 4 4

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

FS 684

4 4 4 4 4 4 4 4 4 4

6.5 13 13 13 22 22 22 30 30 30

20 32 32 32 63 63 63 100 100 100

Rear mounting Surface mounting Flush mounting Rear mounting Surface mounting Flush mounting Rear mounting Surface mounting Flush mounting Rear mounting

Front IP65 IP65 Front IP65 Front IP65 IP65 Front IP65 Front IP65 IP65 Front IP65 Front IP65

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

Ordering Load current switches, changeover switches


http://catalog.moeller.net Contact sequence Moeller HPL0211-2007/2008 Front plate no. Main conducting paths No. of poles Max. motor rating AC-23A 400/415 V 50-60 Hz P Rated uninterrupted current Design

7/27
Rotary switches, switch-disconnectors

T0, T3, T5(B), T6, T8


Protection type Part no. Article no. Price see price list Std. pack

N/O

Iu A

kW Changeover switches With black thumb-grip and grey front plate With 0 (Off) position Group switches, mains transfer switches
1 0 2
0 1 2

4 4 4

6.5 6.5 6.5

20 20 20

Surface mounting Flush mounting Distribution board mounting

IP65 Front IP65 Front IP30

T0-4-8294/I1 207138 T0-4-8294/E 010371 T0-4-8294/IVS 043594

1 off

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

FS 953

4 4 4

13 13 13

32 32 32

Surface mounting Flush mounting Rear mounting

IP65 Front IP65 Front IP65

T3-4-8294/I2 207193 T3-4-8294/E 002513 T3-4-8294/Z 004886 T5B-4-8294/I4 207232 T5B-4-8294/E 092084 T5B-4-8294/Z 092081 T5-4-8294/I5 207433 T5-4-8294/E 095986 T5-4-8294/Z 095984 T3-4-8902/E 215222 T3-4-8902/EZ 215223 T3-4-8902/I2 215224 T3-4-8902/Z 215225 T5B-4-8902/E 207430 T5B-4-8902/I4 207237 T5B-4-8902/Z 207431 T5-4-8902/E 207418 T5-4-8902/I5 207214 T5-4-8902/Z 207419

22

63

Surface mounting

IP65

4 4

22 22

63 63

Flush mounting Rear mounting

Front IP65 Front IP65

4 4 4

30 30 30

100 100 100

Surface mounting Flush mounting Rear mounting

IP65 Front IP65 Front IP65

Mains 0 Stand-by

0
NETZ

NOTSTROM

4 4 4 4 4 4

13 13 13 13 22 22

32 32 32 32 63 63

Flush mounting Flush mounting Flush mounting Flush mounting Flush mounting Surface mounting

Front IP65 Front IP65 IP65 Front IP65 Front IP65 IP65

FS 161629
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

22

63

Rear mounting

Front IP65

4 4 4

30 30 30

100 100 100

Flush mounting Surface mounting Rear mounting

Front IP65 IP65 Front IP65

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

7/28
Rotary switches, switch-disconnectors

Ordering Load current switches, changeover switches


T0, T3, T5(B), T6, T8
Moeller HPL0211-2007/2008 Max. motor rating Rated uninterrupted current Design Protection type Part no. Article no. http://catalog.moeller.net Price see price list Std. pack Front plate no. Main conducting paths No. of poles

Contact sequence

AC-23A 400/415 V 50-60 Hz P

N/O

Iu A

kW Changeover switches With black thumb-grip and grey front plate With 0 (Off) position With spring-return from both directions to 0 0 1 1 2
1 0 2

6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 13 13

20 20 20 20 20 20 20 20 20 20 20 20 32 32

Surface mounting Flush mounting Distribution board mounting Centre mounting Rear mounting Surface mounting Flush mounting Distribution board mounting Centre mounting Surface mounting Flush mounting Centre mounting Surface mounting Flush mounting

IP65 Front IP65 Front IP30 Front IP65 Front IP65 IP65 Front IP65 Front IP30 Front IP65 IP65 Front IP65 Front IP65 IP65 Front IP65

T0-1-8214/I1 207077 T0-1-8214/E 019863 T0-1-8214/IVS 045967 T0-1-8214/EZ 076815 T0-1-8214/Z 050720 T0-2-8215/I1 207103 T0-2-8215/E 022236 T0-2-8215/IVS 048340 T0-2-8215/EZ 081561 T0-3-8216/I1 207434 T0-3-8216/E 024609 T0-3-8216/EZ 086307 T3-3-8216/I2 207184 T3-3-8216/E 023870

1 off

FS 4011

1 2 3 4

1 1 1 1 2 2 2 2 3 3 3 3 3

Without 0 (Off) position Changeover switches


1 2

1 2 3 4 5 6 7 8 9 10 11 12

1 2 3 4 5 6 7 8

1 1 1 1 1

6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 22 22 22 22

20 20 20 20 20 20 20 20 20 32 32 63 63

Surface mounting Flush mounting Distribution board mounting Centre mounting Rear mounting Surface mounting Flush mounting Distribution board mounting Centre mounting Surface mounting Flush mounting Surface mounting Flush mounting

IP65 Front IP65 Front IP30 Front IP65 Front IP65 IP65 Front IP65 Front IP30 Front IP65 IP65 Front IP65 IP65 Front IP65

T0-1-8220/I1 207078 T0-1-8220/E 031728 T0-1-8220/IVS 055459 T0-1-8220/EZ 095799 T0-1-8220/Z 086312 T0-2-8221/I1 207104 T0-2-8221/E 038847 T0-2-8221/IVS 057832 T0-2-8221/EZ 010372 T3-2-8221/I2 207180 T3-2-8221/E 045227 T5B-2-8221/I4 207221 T5B-2-8221/E 093047

1 off

1 2 3 4

FS 943

1 2

2 2 2 2 2 2 2 2
1 2 3 4 5 6 7 8

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

Ordering Load current switches, changeover switches


http://catalog.moeller.net Contact sequence Front plate no.
1 2

7/29
Rotary switches, switch-disconnectors

Moeller HPL0211-2007/2008 Main conducting paths No. of poles N/O Max. motor rating AC-23A 400/415 V 50-60 Hz P kW

T0, T3, T5(B), T6, T8


Rated uninterrupted current Design Protection type Part no. Article no. Price Std. see pack price list

FS 943

Iu A

Changeover switches with black thumb grip and front plate Without 0 (Off) position Changeover switches
1 2

3 3 3 3
1 2 3 4 5 6 7 8 9 10 11 12

6.5 6.5 6.5 6.5 13 22 22 22 22 6.5 6.5 6.5 6.5 6.5 13 13 13 22 22 22 6.5 22 22 6.5 6.5 6.5 22 6.5 6.5 22

20 20 20 20 32 32 63 63 63 20 20 20 20 20 32 32 32 63 63 63 20 32 32 20 20 20 32 20 20 32

Surface mounting Flush mounting Distribution board mounting Centre mounting Flush mounting Surface mounting Surface mounting Flush mounting Rear mounting Surface mounting Flush mounting Distribution board mounting Centre mounting Rear mounting Surface mounting Flush mounting Rear mounting Surface mounting Flush mounting Rear mounting Flush mounting Surface mounting Flush mounting Flush mounting Distribution board mounting Centre mounting Flush mounting Flush mounting Distribution board mounting Flush mounting

IP65 Front IP65 Front IP30 Front IP65 Front IP65 IP65 IP65 Front IP65 Front IP65 IP65 Front IP65 Front IP30 Front IP65 Front IP65 IP65 Front IP65 Front IP65 IP65 Front IP65 Front IP65 Front IP65 IP65 Front IP65 Front IP65 Front IP30 Front IP65 Front IP65 Front IP65 Front IP30 Front IP65

1 2

3
1 2 3 4 5 6 7 8 9 10 11 12

3 3 3 3

1 2

4 4 4 4 4 4 4 4 4 4 4
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

1 2

5 5
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

5
1 2

6
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

6 6 6

1 2

8
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32

8 8

T0-3-8222/I1 207124 T0-3-8222/E 048339 T0-3-8222/IVS 060205 T0-3-8222/EZ 015118 T3-3-8222/E 052346 T3-3-8222/I2 207185 T5B-3-8222/I4 207224 T5B-3-8222/E 092378 T5B-3-8222/Z 092375 T0-4-8223/I1 207137 T0-4-8223/E 050712 T0-4-8223/IVS 062578 T0-4-8223/EZ 019864 T0-4-8223/Z 086315 T3-4-8223/I2 207192 T3-4-8223/E 059465 T3-4-8223/Z 061838 T5B-4-8223/I4 207231 T5B-4-8223/E 092108 T5B-4-8223/Z 092105 T0-5-8369/E 060204 T3-5-8369/I2 207536 T3-5-8369/E 066584 T0-6-8370/E 062577 T0-6-8370/IVS 067324 T0-6-8370/EZ 029356 T3-6-8370/E 073703 T0-8-8372/E 064950 T0-8-8372/IVS 069697 T3-8-8372/E 080822

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

7/30
Rotary switches, switch-disconnectors

Ordering Load-current switch - Safety switch


P1, P3, T5(B)
Moeller HPL0211-2007/2008 Auxiliary contacts Max. motor rating Rated uninterrupted current Design Part no. Article no. http://catalog.moeller.net Price see price list Std. pack Main conducting paths No. of poles

Contact sequence

Front plate no.


ON OFF

AC-23A 400/415 V 50-60 Hz P

FS 908

N/O

N/O

N/C

Iu A

kW Safety switches with warning label For use as Emergency-Stop device1) 3


0 1 1 2 3 4 5 6

0 0 0 0 0 0 0 0 1 1 1 1 0 0 1 1 2 2

0 0 0 0 0 0 0 0 1 1 1 1 0 0 1 1 0 0

13 15 37 50 13 15 37 50 13 15 37 50 22 30 22 30 22 30

25 32 63 100 25 32 63 100 25 32 63 100 63 100 63 100 63 100

3 3 3

Surface mounting IP65

0 1

3+N
1 2 3 4 5 6 N N

3+N 3+N 3+N

0 1

3
1 2 3 4 5 6 13 14 21 22

3 3 3

0 1

6
1 2 3 4 5 6 7 8 9 10 11 12

6 6

6 6

P1-25/I2-SI 207308 P1-32/I2-SI 207329 P3-63/I4-SI 207361 P3-100/I5-SI 207386 P1-25/I2-SI/N 207312 P1-32/I2-SI/N 207333 P3-63/I4-SI/N 207365 P3-100/I5-SI/N 207390 P1-25/I2-SI/HI11 207310 P1-32/I2-SI/HI11 207331 P3-63/I4-SI/HI11 207363 P3-100/I5-SI/HI11 207388 T5B-3-8342/I4-SI 207250 T5-3-8342/I5-SI 207447 T5B-4-15682/I4-SI 207254 T5-4-15682/I5-SI 207285 T5B-4-8903/I4-SI 207258 T5-4-8903/I5-SI 207289

1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off

0 1 0 1

Without Emergency-Stop function2)


0 1

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

3
1 2 3 4 5 6

0 0 0

0 0 0

13 15 37

25 32 63

3 3

Surface mounting IP65

P1-25/I2-SI-SW 207309 P1-32/I2-SI-SW 207330 P3-63/I4-SI-SW 207362

1 off 1 off 1 off

Notes

1) According 2) With

to IEC/EN 60204-1, VDE 0113 Part 1 black rotary handle and locking ring

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

Ordering Load-current switch - Safety switch


http://catalog.moeller.net Contact sequence Moeller HPL0211-2007/2008 Main conducting paths No. of poles Auxiliary contacts Max. motor rating Rated uninterrupted current Design Part no. Article no.

7/31
Rotary switches, switch-disconnectors

P1, P3, T5(B)


Price see price list Std. pack

Front plate no.


ON OFF

FS 908

N/O

N/O

N/C

AC-23A 400/415 V 50-60 Hz P

Iu A

kW Without Emergency-Stop function


0 1

3+N
1 2 3 4 5 6 N N

0 0 0 1 1 1 1 0 1 1 2

0 0 0 1 1 1 1 0 1 1 0

13 15 50 13 15 37 50 22 22 30 30

25 32 100 25 32 63 100 63 63 100 100

3+N 3+N

Surface mounting IP65

0 1

3
1 2 3 4 5 6 13 14 21 22

3 3 3

0 1

6
1 2 3 4 5 6 7 8 9 10 11 12

P1-25/I2-SI/N-SW 207313 P1-32/I2-SI/N-SW 207334 P3-100/I5-SI/N-SW 207391 P1-25/I2-SI/HI11-SW 207311 P1-32/I2-SI/HI11-SW 207332 P3-63/I4-SI/HI11-SW 207364 P3-100/I5-SI/HI11-SW 207389 T5B-3-8342/I4-SI-SW 207251 T5B-4-15682/I4-SI-SW 207255 T5-4-15682/I5-SI-SW 207286 T5-4-8903/I5-SI-SW 207290

1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off

0 1

6
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

6 6

Engineering Maintenance, repair and safety switches all have the same electrical function. They are designed to safely isolate electrical installations (loads) from mains power during maintenance and repair work and to ensure that a hazard does not arise which endangers personnel, machinery and production materials. Safety switches are main switches with an additional enclosure. Installed in the immediate vicinity of the motor or the electrical load they act as switchdisconnectors for that load. It makes possible work without danger according to DIN EN 50110/VDE 0105. This is particularly important if there is any danger of the main switch being inadvertently operated. Application By securing the switch in the OFF position with his own padlock (up to 3 can be fitted), the fitter/electrician can protect himself against the possibility of any other person switching the machine on. Maintenance switches are merely additional, enclosed main switches with a padlocking facility. Enclosed main switch with padlock interlock a 7/10 a 7/30 Features Safety switches are housed in insulated enclosures and bear the inscription Safety switch on a bright orange label. With special red handle and yellow locking ring for Emergency_Stop use according to STOP category O IEC/EN 60204/VDE 0113. If the switch is not usable for Emergency_Stop both parts are black (partno. suffix "SW") The cover and handle can be interlocked by fitting a padlock. Selection Switches must be selected according to the following criteria: 1) according to motor switching capacity, when the switch is fitted in so that the operator may use it for operational ON and OFF switching. 2) The rating data always applies for 3 poles. When the motor rating is divided between 6 poles, such as for star-delta starting, a 6-pole switch can be used to control 1.73 times the rated power. 3) If the switch has a load-shedding contact (LA), you can select the appropriate switch according to the uninterrupted current. The load-shedding contact is an auxiliary contact, which is closed in the ON position and opens early when switching off, so that a contactor located in the circuit takes over the switching capacity and the maintenance/safety switch operates at zero load. When switching on, the loadshedding contact closes later than or at the same time as the main contacts. With P and T switches this is the N/O auxiliary contact.

4) The "ON" position can be locked using a padlock (after altering the handle) This is not permissable for switches with red/yellow handles. Example: Safety switch with load shedding and annunciation
L1 L2 L3 N F1
1 3 4 5

F0

FAZB4/1-HS
95

Q11
2 6

F2
96 21

F2

O
22 13 13

Q11
14 14

11

Q1
2 U 4 V 6 W 8 10 12

M 3

P1

P2

Q11

A1 A2

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

7/32
Rotary switches, switch-disconnectors

Ordering Load current switch - reversing switch


T0, T3, T5B
Moeller HPL0211-2007/2008 Max. motor rating AC-23A 400/415 V 50-60 Hz P kW Rated uninterrupted current Design Protection type Part no. Article no. http://catalog.moeller.net Price see price list Std. pack Front plate no. Main conducting paths No. of poles N/O

Contact sequence

Iu A

Reversing switches with 0 (Off) position with black thumb grip and front plate Without spring-return
1 0 2
0 1 2

6.5

20

Surface mounting Flush mounting Distribution board mounting

IP65 Front IP65 Front IP30 IP65 Front IP65 IP65 Front IP65 IP65 Front IP65 Front IP30 Front IP65 Front IP65 IP65 Front IP65 Front IP65 Front IP65 IP65 Front IP65 Front IP65

FS 684
1 2 3 4 5 6 7 8

T0-2-8400/I1 207111 T0-2-8400/E 053079 T0-2-8400/IVS 060198 T3-2-8400/I2 207181 T3-2-8400/E 073695 T5B-2-8400/I4 207222 T5B-2-8400/E 092918 T0-3-8401/I1 207132 T0-3-8401/E 091047 T0-3-8401/IVS 098166 T0-3-8401/EZ 093420 T0-3-8401/Z 010366 T3-3-8401/I2 207188 T3-3-8401/E 030992 T3-3-8401/EZ 000694 T3-3-8401/Z 035739 T5B-3-8401/I4 207227 T5B-3-8401/E 092296 T5B-3-8401/Z 092293

1 off

22

32

Surface mounting Flush mounting

63

Surface mounting Flush mounting

1 0 2

0 1 2

6.5

20

Surface mounting Flush mounting Distribution board mounting Centre mounting Rear mounting

1 off

FS 684
1 2 3 4 5 6 7 8 9 10

22

32

Surface mounting Flush mounting Centre mounting Rear mounting

63

Surface mounting Flush mounting Rear mounting

With spring-return from both directions to 0


1 0 2

6.5

20

Surface mounting Flush mounting Centre mounting

IP65 Front IP65 Front IP65 IP65

FS 4011
1 2 3 4 5 6 7 8 9 10

T0-3-8228/I1 207125 T0-3-8228/E 015112 T0-3-8228/EZ 048334 T3-3-8228/I2 207186

1 off

22

32

Surface mounting

1 off

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

Ordering Load current switches, (reversing) star-delta switches, (reversing) multi-speed switches
http://catalog.moeller.net Contact sequence Moeller HPL0211-2007/2008 Front plate no. Main conducting paths No. of poles N/O Max. motor rating AC-23A 400/415 V 50-60 Hz P kW Rated Design uninterrupted current

7/33
Rotary switches, switch-disconnectors

T0, T3, T5(B)


Protection Part no. Article no. type Price see price list Std. pack

Iu A

Star-delta switches with black thumb grip and front plate


0 y d
Y 0

6.5

20

FS 635
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

Surface mounting Flush mounting Distribution board mounting Centre mounting Rear mounting

T0-4-8410/I1 207140 Front IP65 T0-4-8410/E 024604 Front IP30 T0-4-8410/IVS 064945 Front IP65 T0-4-8410/EZ 053080 Front IP65 T0-4-8410/Z 083929 T3-4-8410/I2 207195 Front IP65 T3-4-8410/E 009657 Front IP65 T3-4-8410/EZ 000721 Front IP65 T3-4-8410/Z 012030 T5B-4-8410/I4 207234 Front IP65 T5B-4-8410/E 092052 IP65 IP65

IP65

1 off

22

32

Surface mounting Flush mounting Centre mounting Rear mounting

63

Surface mounting Flush mounting

Reversing Star-delta switches with black thumb grip and front plate Two-way switches
d y 0 y d
0 Y Y

6.5 22

20 32

Flush mounting Surface mounting Flush mounting Rear mounting

Front IP65 T0-5-15876/E 000893 T3-5-15876/I2 207537 Front IP65 T3-5-15876/E 016776 Front IP65 T3-5-15876/Z 019149 Front IP65 T5B-5-15876/E 214785 Front IP65 T5B-5-15876/Z 214786 IP65

1 off

FS 638

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

d y 0 y d

63

Flush mounting Flush mounting

FS 4017

Reversing multi-speed switches with black thumb grip and front plate Two-speed, two directions, for one tapped winding
2 1 0 1 2
0 1 2 1 2

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

6.5

20

Flush mounting Centre mounting Rear mounting

FS 629

Front IP65 T0-6-15866/E 055460 Front IP65 T0-6-15866/EZ 012747 Front IP65 T0-6-15866/Z 067326 Front IP65 T3-6-15866/E 054744 Front IP65 T5B-7-15866/E 214788

1 off

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

22
2 1 0 1 2
0

32 63

Flush mounting Flush mounting

1 2

1 2

22

1 off

FS 441

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

7/34
Rotary switches, switch-disconnectors

Ordering Control switch, multi-speed switch


T0, T3, T5B
Moeller HPL0211-2007/2008 Main conducting paths No. of poles Max. motor rating AC-23A Rated uninterrupted current Design Protection type Part no. Article no. http://catalog.moeller.net Price see price list Std. pack Front plate no.

Contact sequence

N/O

400/415 V 50-60 Hz P

Iu A

kW Multi-speed switches with black thumb grip and front plate Two-speed, non reversing, for 2 separate windings 1 3 2
0 1 2
0

6.5

20

Surface mounting Flush mounting

IP65 Front IP65

1 2 3 4 5 6 7 8 9 10 11 12

FS 644

T0-3-8451/I1 207133 T0-3-8451/E 038849 T0-3-8451/IVS 026985 T0-3-8451/EZ 083936 T3-3-8451/I2 207189 T3-3-8451/E 028641

1 off

Distribution board mounting Centre mounting

Front IP30

Front IP65

22

32

Surface mounting Flush mounting

IP65 Front IP65

2-speed, 1 directions, for tapped winding


0 1 2
1 0 2

6.5

20

Surface mounting Flush mounting

IP65 Front IP65

FS 644
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

T0-4-8440/I1 207141 T0-4-8440/E 041222 T0-4-8440/IVS 029358 T0-4-8440/EZ 088682 T0-4-8440/Z 048342 T3-4-8440/I2 207196 T3-4-8440/E 035760 T5B-4-8440/E 092032 T0-4-8441/I1 207142 T0-4-8441/E 043595 T0-4-8441/IVS 031731 T3-4-8441/I2 207197 T3-4-8441/E 042879 T5B-4-8441/Z 092025

1 off

Distribution board mounting Centre mounting

Front IP30

Front IP65

Rear mounting

Front IP65

22

32

Surface mounting Flush mounting

IP65 Front IP65

63

Flush mounting

Front IP65

1 0 2

0 1 2

6.5

20

Surface mounting Flush mounting

IP65 Front IP65

1 off

FS 684
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

Distribution board mounting 22 32 Surface mounting Flush mounting

Front IP30

IP65 Front IP65

63

Rear mounting

Front IP65

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

Ordering Control switch, step switch


http://catalog.moeller.net Contact sequence Moeller HPL0211-2007/2008 Front plate no. No. of poles Design Protection type Part no. Article no.

7/35
Rotary switches, switch-disconnectors

T0
Price see price list Std. pack

Step switches With black thumb-grip and grey front plate One contact closed per step (without overlap) With 0 (Off) position
0 1 2

1 0

Surface mounting Flush mounting Centre mounting

IP 65 Front IP 65 Front IP 65 IP 65 Front IP 65 Front IP 30 Front IP 65 IP 65 Front IP 65 Front IP 30 Front IP 65 IP 65 Front IP 65 Front IP 30 Front IP 65 Front IP 65 Front IP 30 Front IP 65 IP 65 Front IP 65 Front IP 65 Front IP 65 Front IP 30 Front IP 65 Front IP 65 Front IP 65 Front IP 30 Front IP 65

T0-1-8240/I1 207079 T0-1-8240/E 034105 T0-1-8240/EZ 043597 T0-2-8241/I1 207107 T0-2-8241/E 050716 T0-2-8241/IVS 057835 T0-2-8241/EZ 053089 T0-2-8242/I1 207108 T0-2-8242/E 067327 T0-2-8242/IVS 074446 T0-2-8242/EZ 069700 T0-3-8243/I1 207128 T0-3-8243/E 081565 T0-3-8243/IVS 088684 T0-3-8243/EZ 083938 T0-3-8244/E 095803 T0-3-8244/IVS 012749 T0-3-8244/EZ 098176 T0-3-8280/I1 207130 T0-3-8280/E 034106 T0-3-8280/EZ 036479 T0-5-8281/E 048344 T0-5-8281/IVS 055463 T0-5-8281/EZ 050717 T0-5-8281/Z 057836 T0-6-8282/E 062582 T0-6-8282/IVS 069701 T0-6-8282/EZ 064955

FS 418
1 2 3 4

0 1 2 3

1 0

Surface mounting Flush mounting Distribution board mounting Centre mounting

FS 420
1 2 3 4 5 6

0 1 2 3 4

1 0

3 4

Surface mounting Flush mounting Distribution board mounting Centre mounting

FS 422
1 2 3 4 5 6 7 8

0 1 2 3 4 5

1 0

3 4 5

Surface mounting Flush mounting Distribution board mounting Centre mounting

FS 424

1 2 3 4 5 6 7 8 9 10

0 1 2 3 4 5 6

1 0

3 4 5

Flush mounting Distribution board mounting Centre mounting

FS 426

1 2 3 4 5 6 7 8 9 10 11 12

0 1 2

1 0

Surface mounting Flush mounting Centre mounting

1 2 3 4 5 6 7 8 9 10 11 12

FS 418

0 1 2 3

1 0

Flush mounting Distribution board mounting Centre mounting Rear mounting

FS 420
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18

0 1 2 3 4

1 0

3 4

Flush mounting Distribution board mounting Centre mounting

FS 422
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

7/36
Rotary switches, switch-disconnectors

Ordering Control switch, step switch


T0
Moeller HPL0211-2003 Front plate no. No. of poles Design Protection type Part no. Article no. http://catalog.moeller.net Price see price list Std. pack

Contact sequence

Step switches With black thumb-grip and grey front plate One contact closed per step (without overlap) Without 0 (Off) position
1 2

1 1 1 1 1

Surface mounting Flush mounting Distribution board mounting Centre mounting Rear mounting Surface mounting Flush mounting Distribution board mounting Centre mounting Surface mounting Flush mounting Distribution board mounting Centre mounting Flush mounting Distribution board mounting Centre mounting Surface mounting Flush mounting Distribution board mounting Centre mounting Flush mounting Centre mounting Surface mounting Flush mounting Distribution board mounting Centre mounting Flush mounting Distribution board mounting Centre mounting Flush mounting Centre mounting

IP65 Front IP65 Front IP30 Front IP65 Front IP65 IP 65 Front IP 65 Front IP 30 Front IP 65 IP 65 Front IP 65 Front IP 30 Front IP 65 Front IP 65 Front IP 30 Front IP 65 IP 65 Front IP 65 Front IP 30 Front IP 65 Front IP 65 Front IP 65 IP65 Front IP65 Front IP30 Front IP65 Front IP 65 Front IP 30 Front IP 65 Front IP 65 Front IP 65

T0-1-8220/I1 207078 T0-1-8220/E 031728 T0-1-8220/IVS 055459 T0-1-8220/EZ 095799 T0-1-8220/Z 086312 T0-2-8230/I1 207105 T0-2-8230/E 088685 T0-2-8230/IVS 095804 T0-2-8230/EZ 091058 T0-2-8231/I1 207106 T0-2-8231/E 012750 T0-2-8231/IVS 019869 T0-2-8231/EZ 015123 T0-3-8232/E 026988 T0-3-8232/IVS 034107 T0-3-8232/EZ 029361 T0-3-8233/I1 207127 T0-3-8233/E 041226 T0-3-8233/IVS 048345 T0-3-8233/EZ 043599 T0-4-8251/E 013971 T0-4-8251/EZ 013972 T0-3-8222/I1 207124 T0-3-8222/E 048339 T0-3-8222/IVS 060205 T0-3-8222/EZ 015118 T0-5-8270/E 091059 T0-5-8270/IVS 098178 T0-5-8270/EZ 093432 T0-6-8271/E 015124 T0-6-8271/EZ 017497

1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off

1 2 3 4

FS 943

1 2 3

2 1

1 1 1 1

1 2 3 4 5 6

FS 404

1 2 3 4

2 1

3 4

1 1 1 1

FS 606
1 2 3 4 5 6 7 8

1 2 3 4 5

2 1

4 5

1 1 1

FS 408
1 2 3 4 5 6 7 8 910

1 2 3 4 5 6

2 1

4 5 6

1 1 1 1

FS 410

1 2 3 4 5 6 7 8 9 10 11 12

1 2 3 4

2 1

2 2

FS 406
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

1 2

3 3 3 3

1 2 3 4 5 6 7 8 9 10 11 12

FS 943

1 2 3

2 1

3 3 3

FS 404
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18

1 2 3 4

2 1

3 3

FS 406
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

Ordering Control switch, ON-OFF switches, changeover switches, Hand/Auto switches


http://catalog.moeller.net Contact sequence Moeller HPL0211-2003 Front plate no. No. of poles Design Protection type Part no. Article no. Price see price list

7/37
Rotary switches, switch-disconnectors

Std. pack

On-Off switches With black thumb-grip and grey front plate One contact closed per step (without overlap)
0 1

1 1 1 1

Flush mounting Centre mounting Surface mounting Distribution board mounting Flush mounting Centre mounting Surface mounting Distribution board mounting Flush mounting Centre mounting Distribution board mounting Flush mounting Centre mounting

Front IP 65 Front IP 65 IP 65 Front IP30 Front IP 65 Front IP 65 IP 65 Front IP30 Front IP 65 Front IP 65 Front IP30 Front IP 65 Front IP 65

FS 415

T0-1-15401/E 038854 T0-1-15401/EZ 041227 T0-1-15401/I1 207067 T0-1-15401/IVS 045973 T0-1-15402/E 053092 T0-1-15402/EZ 055465 T0-1-15402/I1 207068 T0-1-15402/IVS 060211 T0-2-15403/E 067330 T0-2-15403/EZ 069703 T0-2-15403/IVS 074449 T0-2-15404/E 081568 T0-2-15404/EZ 083941

1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off

1 2

0 1

2
1 2 3 4

2 2 2

0 1

3
1 2 3 4 5 6

3 3

0 1

4
1 2 3 4 5 6 7 8

Changeover switches With black thumb-grip and grey front plate One contact closed per step (without overlap)
2 0 1

1 1 1 1

Flush mounting Centre mounting Surface mounting Distribution board mounting Flush mounting Distribution board mounting Centre mounting Rear mounting Surface mounting Flush mounting

Front IP 65 Front IP 65 IP 65 Front IP30 Front IP 65 Front IP30 Front IP 65 Front IP 65 IP 65 Front IP 65

1 2 3 4

FS 429

T0-1-15421/E 095806 T0-1-15421/EZ 098179 T0-1-15421/I1 207069 T0-1-15421/IVS 012752 T0-2-15422/E 019871 T0-2-15422/IVS 026990 T0-2-15422/EZ 022244 T0-2-15422/Z 029363 T0-3-15423/I1 207114 T0-3-15423/E 034109

1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off

2 0 1

2 2
1 2 3 4 5 6 7 8

2 2
2 0 1

3 3

Hand/Auto switches With 0 (Off) position Without spring-return


AUTO 0 HAND
HAND AUTO

1 2 3 4 5 6 7 8 9 10 11 12

Surface mounting Flush mounting Distribution board mounting Centre mounting Rear mounting

IP65 Front IP 65 IP65 Front IP 65 Front IP 65

T0-1-15431/I1 207070 T0-1-15431/E 019872 T0-1-15431/IVS 026991 T0-1-15431/EZ 022245 T0-1-15431/Z 029364

1 off

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

1 2 3 4

FS 1401

7/38
Rotary switches, switch-disconnectors

Ordering Control switch - hand/auto switch


T0
Contact sequence Front plate no. No. of poles Design Moeller HPL0211-2007/2008 Protection type Part no. Article no. http://catalog.moeller.net Price see price list Std. pack

Hand/Auto switches With 0 (Off) position AUTO Without spring0 return HAND
1 2 3 4 5 6 7 8

HAND AUTO

Surface mounting Flush mounting Distribution board mounting Centre mounting Rear mounting

IP65 Front IP 65 IP65 Front IP 65 Front IP 65 IP65 Front IP 65 IP65 Front IP 65 Front IP 65 IP65 Front IP 65 Front IP 65 IP65 Front IP 65 IP65 Front IP65 Front IP65 Front IP65

T0-2-15432/I1 207091 T0-2-15432/E 034110 T0-2-15432/IVS 041229 T0-2-15432/EZ 036483 T0-2-15432/Z 043602 T0-3-15433/I1 207115 T0-3-15433/E 048348 T0-3-15433/IVS 055467 T0-3-15433/EZ 050721 T0-3-15433/Z 057840 T0-1-15434/I1 207071 T0-1-15434/E 062586 T0-1-15434/EZ 018053 T0-2-15435/I1 218971 T0-2-15435/E 003191 T0-2-15907/I1 207095 T0-2-15907/E 066931 T0-2-15907/EZ 069304 T0-2-15907/Z 078796 T0-1-15451/I1 207072 T0-1-15451/E 076824 T0-1-15451/IVS 083943 T0-1-15451/EZ 079197 T0-1-15451/Z 086316 T0-2-15452/E 091062 T0-2-15452/IVS 098181 T0-2-15452/EZ 093435 T0-3-15453/E 015127 T0-3-15453/IVS 022246 T0-3-15453/EZ 017500 T0-3-15453/Z 024619

1 off

FS 1401

AUTO 0 HAND

HAND AUTO

Surface mounting Flush mounting Distribution board mounting Centre mounting Rear mounting

1 off

With spring-return from HAND

1 2 3 4 5 6 7 8 9 10 11 12

FS 1401

AUTO 0 HAND

HAND AUTO

Surface mounting Flush mounting Centre mounting

1 off

FS 1414000
1 2 3 4

AUTO 0 HAND

HAND AUTO

Layout Flush mounting

1 off

FS 1414000
1 2 3 4 5 6 7 8

With spring-return from START

START HAND 0 AUTO

AUTO

1
HAND START

Surface mounting Flush mounting Centre mounting Rear mounting

1 off

FS 1413890

Without 0 (Off) position AUTO Without springHAND return


1 2 3 4

1 2 3 4 5 6 7 8

HAND AUTO

Surface mounting Flush mounting Distribution board mounting Centre mounting Rear mounting

IP65 Front IP65 Front IP30 Front IP65 Front IP65 Front IP65 Front IP30 Front IP65 Front IP65 Front IP30 Front IP65 Front IP65

1 off

FS 19334

AUTO HAND

HAND AUTO

Flush mounting Distribution board mounting Centre mounting

1 off

FS 19334

1 2 3 4 5 6 7 8

AUTO HAND

HAND AUTO

Flush mounting Distribution board mounting Centre mounting Rear mounting

1 off

FS 19334

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

1 2 3 4 5 6 7 8 9 10 11 12

Ordering Control switch - ON switches, universal control switches


http://catalog.moeller.net Contact sequence Moeller HPL0211-2007/2008 Front plate no. Pole Design Protection type Part no. Article no.

7/39
Rotary switches, switch-disconnectors

T0
Price see price list Std. pack

On switches with black thumb grip and front plate ON spring-return switches (make contact) Spring-return in position 1
I 1
1

Flush mounting Centre mounting

Front IP65 Front IP65 Front IP65 IP65 Front IP65

FS 4721

T0-1-15321/E 086317 T0-1-15321/EZ 088690 T0-1-15322/E 010382 T0-2-15323/I1 207087 T0-2-15323/E 024620

1 off

1 2

I 1

2
1 2 3 4

Flush mounting Surface mounting Flush mounting

I 1

3
1 2 3 4 5 6

On-Off spring-return switches Spring-return in positions 0 and 1


0 1

Flush mounting Centre mounting

Front IP65 Front IP65

ON-OFF spring-return switch Spring-return in START position


START 1 0
1 0
START

1 2 3 4

FS 456

T0-1-15366/E 081572 T0-1-15366/EZ 083945

Surface mounting Flush mounting Centre mounting Rear mounting

IP65 Front IP65 Front IP65 Front IP65 IP65 Front IP65 Front IP65 Front IP65 Front IP65 Front IP65

T0-1-15511/I1 207073 T0-1-15511/E 019875 T0-1-15511/EZ 022248 T0-1-15511/Z 029367 T0-2-15512/I1 207093 T0-2-15512/E 034113 T0-2-15512/EZ 036486 T0-2-8177/E 015130 T0-2-8177/EZ 017503 T0-2-8177/Z 024622

1 2 3 4

FS 147767

START 1 0

Surface mounting Flush mounting

1 2 3 4 5 6 7 8

Centre mounting
START 2 0 1 START
0

1
START

2
START

see K 115

Flush mounting Centre mounting Rear mounting

FS 140660

Universal control switches With black thumb-grip and grey front plate 1 contact closed in each position Additionally 1 contact closed in position 0 and 1 Additionally 1 contact closed in position 0 and 2 Additionally 1 contact closed in position 0 and 3 Stay-put switches with 3 positions
2 0 1

1 2 3 4 5 6 7 8

Flush mounting Centre mounting

Front IP65 Front IP65

FS 429

T0-3-15391/E 029365 T0-3-15391/EZ 031738 T0-3-15394/E 072079 T0-3-15394/IVS 079198 T0-3-15394/EZ 074452

1 off

Spring-return from positions 1 and 2


2 0
2 0 1

1 2 3 4 5 6 7 8 9 10 11 12

Flush mounting Distribution board mounting Centre mounting

Front IP65 Front IP30 Front IP65

FS 458

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

1 2 3 4 5 6 7 8 9 10 11 12

7/40
Rotary switches, switch-disconnectors

Ordering Control switches, instrument selector switches


T0
Moeller HPL0211-2007/2008 Front plate no. Pole Design Protection type Part no. Article no. http://catalog.moeller.net Price see price list Std. pack

Contact sequence

Coding switches With black thumb-grip and grey front plate With complete rotation in both directions
1 0 2 3 4

0 1 2 3 4 5 6 7 8 9

9 8

5 6 7

Dual BCD CODE

Flush mounting Centre mounting

Front IP65 Front IP65

FS 312

T0-4-15602/E 029368 T0-4-15602/EZ 031741

1 off

Series switches With black thumb-grip and grey front plate With 0 (Off) position (heater switches)
0 1 2

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

1 0

Flush mounting

Front IP65

T0-1-91/E 072082

FS 614

Voltmeter selector switches With black thumb-grip and grey front plate
L3-N L2-N L1-N 0
L2-N L1-N L3-N 0

1 2 3 4

3 x phase to N with 0 (Off) position

Flush mounting

Front IP65

T0-2-15921/E 067337

1 off

FS 1410757

1 2 3 4 5 6 7 8

L3-N L2-N L1-N 0 L1-L2 L2-L3 L3-L1

L1-L2 L2-L3 L3-L1

L1-N L2-N L3-N

3 x phase to phase + 3 x phase to N with 0 (Off) position

Flush mounting Distribution board mounting Centre mounting

Front IP65 Front IP30 Front IP65 Front IP65

FS 1410759

T0-3-8007/E 095813 T0-3-8007/IVS 012759 T0-3-8007/EZ 098186 T0-3-8007/Z 015132 T0-3-15924/E 019878 T0-3-15924/IVS 026997 T0-3-15924/EZ 022251 T0-2-15920/E 038861 T0-2-15920/IVS 029452 T0-2-15920/EZ 041234 T0-2-15920/Z 048353 T0-2-15922/E 053099 T0-2-15922/EZ 055472

1 off

1 2 3 4 5 6 7 8 9 10 11 12

Rear mounting

L3-N L2-N L1-N L3-L1 L2-L3 L1-L2

L2-L3 L3-L1 L1-L2 L3-N L2-N L1-N

FS 164721

3 x phase to phase + 3 x phase to N Without 0 position with complete rotation in both directions

Flush mounting Distribution board mounting Centre mounting

Front IP65 Front IP30 Front IP65

1 off

1 2 3 4 5 6 7 8 9 10 11 12

L3-L1 L2-L3 L1-L2 0

L2-L3 L1-L2 L3-L1 0

3 x phase to phase with 0 (Off) position

Flush mounting Distribution board mounting Centre mounting

Front IP65 Front IP30 Front IP65 Front IP65

1 off

FS 1410755

1 2 3 4 5 6 7 8

Rear mounting

L3-L1 L2-L3 L1-L2

L2-L3 L1-L2 L3-L1

3 x phase to phase without 0 (Off) position

Flush mounting Centre mounting

Front IP65 Front IP65

1 off

FS 164854

Ammeter selector switches With black thumb-grip and grey front plate With complete rotation in both directions Measurement via current transformers
0
L3 L2 L1

1 2 3 4 5 6 7 8

With 0 (Off) position

Flush mounting Distribution board mounting Centre mounting

Front IP65 Front IP30 Front IP65

FS 9440

T0-3-8048/E 034116 T0-3-8048/IVS 041235 T0-3-8048/EZ 036489

1 off

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

1 2 3 4 5 6 7 8 9 10 11 12

Ordering Switches with locking mechanism


http://catalog.moeller.net Contact sequence Front plate no. Moeller HPL0211-2007/2008 No. of poles Max. motor rating AC-23A 400/415 V 50-60 Hz P Iu A Rated uninterrupted current Design Protection type Part no. Article no.

7/41
Rotary switches, switch-disconnectors

T0, P1
Price see price list Std. pack

kW

Panic switch Cylinder lock SVA Key withdrawable in position 0 and 1 If the key is withdrawn in position 1 the switch can be switched off but not on again without the key. With Emergency-Stop function According to IEC/EN 60204-1, VDE 0113 Part1 with red thumb-grip and yellow front plate 1 3 6.5 20 Layout
0 1
0

IP65 IP65

3
FS 908 GE

13

25
OFF

ON

Layout

T0-2-1/I1/SVA(S)-RT 207085 P1-25/I2/SVA(S)-RT 207306 T0-2-1/E/SVA(S)-RT 228291 P1-32/E/SVA(S)-RT 050971

1 off 1 off

1 2 3 4 5 6

6.5

20

Flush mounting Flush mounting

IP65

1 off

15

32

IP65

1 off

0 1

Without Emergency-Stop function with black thumb grip and front plate 3 6.5
ON OFF

20 25
OFF
ON

Layout Layout

IP65 IP65

FS 908

13

T0-2-1/I1/SVA(S) 207084 P1-25/I2/SVA(S) 207305 T0-2-1/E/SVA(S) 050977 P1-32/E/SVA(S) 044977

1 off 1 off

1 2 3 4 5 6

6.5

20

Flush mounting Flush mounting

IP65

1 off

15

32

IP65

1 off

0 1

Padlocking feature SVC Interlocking slide with lock lockable in positions 0 and 1 If the interlocking slide is interlocked with lock in position 1 the switch can be switched off but not on again without removing the lock. Lockable with max. 3 padlocks. With Emergency-Stop function According to IEC/EN 60204-1, VDE 0113 Part1 with red thumb-grip and yellow front plate 1 3 6.5 20 Layout IP65
0

T0-2-1/I1/SVC(S)-RT 207086

1 off

1 2 3 4 5 6

FS 908 GE

Notes

C B

D
330 300 315

E
0 30 45

G H

60 90

A R Q

270 240 225 135 210 180 150

J K

120

Code letters for lockable switch positions Letter S for panic lock with FS908GE

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

7/42
Rotary switches, switch-disconnectors

Ordering Switches with locking mechanism


T0, P1
Contact sequence Front plate no. No. of poles Max. motor rating AC-23A 400/415 V 50-60 Hz P Iu A Rated uninterrupted current Product view Moeller HPL0211-2007/2008 Design Protection type Part no. Article no. http://catalog.moeller.net Price see price list Std. pack

kW On-Off switch with black thumb grip and front plate Key can only be withdrawn in position 0 (Pos A) Without Emergency-Stop function Cylinder lock SVA 2 6.5
0 1
ON OFF

20

Layout

IP65

T0-1-102/I1/S 207063

1 off

1 2 3 4

FS 908

0 1

ON OFF

6.5

20

Flush mounting

IP65

T0-1-102/EZ/S 014933

1 off

1 2 3 4

FS 908

Key operation ST-0, IP53


0 1
ON OFF

3 3

6.5 13

20 25
OFF
ON

Layout Layout

IP65 IP65

FS 908

T0-2-1/I1/SVA(A) 207083 P1-25/I2/SVA(A) 207304 T0-2-1/E/SVA(A) 050976 P1-25/E/SVA(A) 050965 T0-2-1/Z/SVA(A) 050978

1 off 1 off

1 2 3 4 5 6

6.5

20

Flush mounting Flush mounting Rear mounting


ON
OFF

IP65

1 off

3 3

13 6.5

25 20

IP65 IP65

1 off 1 off

Notes

C B

D
330 300 315

E
0 30 45

G H

60 90

A R Q

270 240 225 135 210 180 150

J K

120

Code letters for lockable switch positions Letter S for panic lock with FS908GE

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

Ordering Main switch assembly kits, thumb-grips, maintenance keys


http://catalog.moeller.net Moeller HPL0211-2007/2008 For use with Part no. Article no.

7/43
Rotary switches, switch-disconnectors

SVB-...-T0(P3), KNB-...-T0(P3)
Price see price list Std. pack Notes

Main switch assembly kits Padlocking feature, exclusively for main switches Admissible on T0 up to 4 contact units Admissible on T3 up to 6 contact units With red rotary as Emergency-Stop handle and yellow device according to locking ring IEC/EN 60204-1, VDE 0113 Part 1

T0-.../E, .../Z, .../I1 T3-.../E, .../Z, .../I2 P1-.../E, .../Z, .../I2 T5B-.../E, .../Z, .../I4 T5-.../E, .../Z, .../I5 P3-63/E, .../Z, .../I4 P3-100/E, .../Z, .../I5 T0-.../E, .../Z, .../I1 T3-.../E, .../Z, .../I2 P1-.../E, .../Z, .../I2 T5B-.../E, .../Z, .../I4 T5-.../E, .../Z, .../I5 P3-63/E, .../Z, .../I4 P3-100/E, .../Z, .../I5

SVB-T0 057892 SVB-P3 052999

1 off

1 off

for interlocking the 0 position for switches with positions 0 I at 90 Switching angle as front plate FS908 Lockable with max. 3 padlocks for interlocking the 0 position for interlocking the I position when required Lockable with max. 3 padlocks

With black rotary handle and black locking ring

Without EmergencyStop function

SVB-SW-T0 060265 SVB-SW-P3 062491

1 off

1 off

Main switch assembly kits with PE terminal and N terminal With red rotary as Emergency-Stop T0-.../E, .../Z handle and yellow device according to T3-.../E, .../Z locking ring IEC/EN 60204-1, T5(B)-.../E, .../Z VDE 0113 Part 1

V/EA/SVB-T0 062638 V/EA/SVB-T5 045065

1 off 1 off

With black rotary handle and black locking ring Thumb-grips Black Red, only for Emergency-Stop switch, according to IEC/EN 60204-1, VDE 0113 Part 1 Black Red, only for Emergency-Stop switch, according to IEC/EN 60204-1, VDE 0113 Part 1

Without EmergencyStop function

T0-.../E, .../Z T3-.../E, .../Z T5(B)-.../E, .../Z

V/EA/SVB-SW-T0 065011 V/EA/SVB-SW-T5 045064 KNB-T0 038909 KNB-RT-T0 043655

1 off 1 off

For conversion of T.../E flush mounting switches with front plate FS908 into T.../EA/SVB... flush mounting main switches. For conversion of T.../Z rear mounting switches (with front plate FS908) into interlocked T.../V/SVB rear mounting main switches

10 off 10 off Order additional yellow front plate FS908GE-T0

KNB-P3 041282 KNB-RT-P3 046028

10 off 10 off Order additional yellow front plate FS908GE-P3

Maintenance key for locked main switch For interlocked main switches For interlocked main switches

KNK-T0 000650 KNK-P3 000649

5 off

5 off

Special devices for electricians, to allow them to switch interlocked main switches On and Off, when the panel door is open for maintenance purposes (to IEC/ EN 60204-1, Clause 5.1.1.1)

ATEX style According to 94/9EG Test Certificate BVS04E106X Only available together with basic device with metric knock-outs M20

T0-.../I1 T3-.../I2 P1-.../I2 T5B-.../I4 P3-.../I4 T5-.../I5 P3-.../I5

with solid side walls

+ATEX-I1 237513 +ATEX-I2 237514 +ATEX-I4 237516 +ATEX-I5 237517

1 off 1 off 1 off 1 off

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

7/44
Rotary switches, switch-disconnectors

Ordering Front plates


FS-T0(P3)
Size Dimensions (W x H x D) mm Moeller HPL0211-2007/2008 Part no. Article no. http://catalog.moeller.net Price see price list Std. pack

Standard front plates Can be laser inscribed T0, T3, P1 P3, T5, T5B Emergency-Stop front plates T0, T3, P1 P3, T5, T5B Blank plates Can be engraved P3, T5, T5B T0, T3, P1 84 x 84 (for size 88 x 88) 45 x 45 (for size 48 x 48) FS-ALU980-P3 266906 FS-ALU980-T0 266905 10 off 50 off 45 x 45 (for size 48 x 48) 84 x 84 (for size 88 x 88) FS908GE-T0 003198 FS908GE-P3 031475 5 off 5 off 45 x 45 (for size 48 x 48) 84 x 84 (for size 88 x 88) FS(*)-T0 231893 FS(*)-P3 231895 10 off 10 off

Notes Standard front plates For standard contact sequence the normal front plate can be replaced if required with the front plate shown here (not with T6, T8 and TM). This is provided the switching angle, number of positions and the position of the 0 position are the same. Switching angle 30
1 0 23 2 1 34 1 0 234 345 2 1 1 0 2 34 5 2 1 3 45 6 2 34 5 1 6 0 1 0 2 34 5 6 7 2 1 345 6 7 8 1 0 234 8 5 6 7 2 1 345 9 6 7 8 1 0 2 3 4 5 6 7 2 1 345 10 9 6 7 8 1 0 234 5 6 7 2 1 345 6 7 8 1110 9 2 34 5 1 6 0 11 7 10 9 8 345 2 6 1 7 12 8 1110 9

9 8

10 9 8

318

309

317

308

316

307

315

314

305

313

304

312

303

311

302

310

301

Switching angle 45
1 0 2 1 0 1
STOP START OFF ON HAND AUTO

STOP START

1 2

HAND AUTO

416
AUS AUTO HAND

402
OFF AUTO HAND AUS LANG- SCHNELL SAM

415
HALT LINKS RECHTS

142003
HALT ZUVOR. RUCK

147472
STOP FORW. REV.

141883
1 0
START

455

141879
0 1 2

4721
2 0 1

4722

4723
0 1 2

496
2 0 1

41409
HAND

429
OFF HAND AUTO

1401

AUTO

1411
1 0 2

1420
2 0 1

1475
0
AUS EIN

1404
0
AUF ZU

1403
0
TRIP CLOSE

141538
0
RAISE LOWER

147767
0
LINKS RECHTS

461
1
AUS EIN STOP

4026
STOP AUTO

462
0
HAND START

4117
1 0 2 2 1 3

1414000
1 0 2 3

1413905
2 1 3 4 1 0 2 3 4

1
START

FORW.

REV.

4011
2 1 3 4 5

458
1 2 0 1 2

1426
3 4 0 1 2

14988
Y 0 Y

147474

1413903
1 2 0 1 2

1446
2
START

456
1
START

1423
2
STOP FORW. REV. START START

14510

141537
START

1413890
1 0 2 3 4 5 2 1

418
3 4 5 6

404
1 0 2 3 4 5

420
2 1 3 4 5 7 6

406
1 2 3 0 1 2 3 1 0 7

422
2 3 4 5

1
START

START

START

408
2 1 8 7 3 4 5 6

441
0

453
L2-N L1-N L3-N

4017
S-O R-O T-O L2-L3 L1-L2 L3-L1 R-S

459
S-T T-R

1409
L1-L2 L2-L3 L3-L1 L1-N

140660
0
L1-L2 L1-N L2-N L3-N

14712
L1-L2 L2-L3 L3-L1

142074
OFF L1-L2 L2-L3 L3-L1 L1-N L2-N L3-N R-S S-T T-R

424
OFF L1-L2 L2-L3 L3-L1 L1-L2 L2-L3 L3-L1 R-S S-T T-R

410
OFF L3-L1 L1-L2 L2-L3

426
OFF L3-N L2-N L1-N

412
0
START

449
1

428

L1-N L2-N L3-N

R-O S-O T-O

R-S S-T T-R

414

1410757

14196

1410755

14195

1410756

1410758

1410759

147479

14944

1410763

140055

194321

194323

142010

Switching angle 60
0 1 1 2
HAND AUTO

1 0 2

SLOW STOP FAST

Y 0

START STOP RUN

0 1 2 2

0 1
NETZ

NOTSTROM AUF

0
AB AUF

HALT AB

HALT LINKS RECHTS

AUS HAND AUTO AUTO

AUS HAND

OFF HAND AUTO

OFF

611
OFF AUTO MAN

601
OFF REV. FORW.

1601
STOP SLOW FAST

644
STOP FORW. REV.

16052
1 2 3

635
L2-N L1-N L3-N

16616
L2-L3 L1-L2 L3-L1

684
1 0 2 1

621
2 3

161629

161570
1 0 2 3

161359
LOW OFF MED. HIGH

161358
2 1 3 4

1610

1614
0 Y

1673

1617

1627
START

1628

1662

1665
2 1

655
0 3 4

164855
3 4 0 1 2

164854
0 1 2 1 2
STOP SLOW SLOW FAST FAST

614
0 Y Y

604
STOP START START

616
1 0 2 3 4

160772
1 0 5 4 2 3 1

606
2 6 3 4 5 2 1 0 1 2

6034
0 Y Y
L2-L3 L1-L2 L3-L1 L3-N L1-N S-T R-S T-O S-O T-R R-O

1 0

RUN

RUN

L2-N

164222

667

645

629

161002

638

161683

618

620

610

640

6010

164721

661

Switching angle 90
ON OFF

1 0 1
HEIZUNGNOTSCHALTER

2
AUS

EIN STOP

0 1

AUS

EIN

STOP

START

HAND

AUTO

AUF

ZU

AUF

AB

UP

DOWN

SLOW

FAST

908
1 0 2 1

9508
0 2 1

902
OFF

190719
2 2 1 3

193935
1 0 1 0
OFF ON ON OFF

907
OFF ON OFF ON

945
1 2 1 2 0 2 1 0 1

1992
0 2 0

190334
1 0 2 1+2 3

943
0 1 2

19334
1 0 3 2

190550
2 1 4 3

19143
0
L3 L2 L1

193975
0 T S R

190431
OFF L3 L2 L1 ZU AUS AUTO AUF

910

953

192190

904

926

1957

192191

923

928

9441

193840

911

912

906

9440

935

19589

1922

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

Ordering Add-on front plates


http://catalog.moeller.net Explanation Moeller HPL0211-2007/2008 Language For use with Part no. Article no.

7/45
Rotary switches, switch-disconnectors

ZFS
Price see price list Std. pack

Add-on front plates, clip-on for padlocking feature consists of label mount and insert label Inscribed with standard text "main switch only open in 0 position" in various languages Blank, can be engraved

Blank, can be engraved Blank, can be engraved Engraved with standard text Engraved with standard text Engraved with standard text Engraved with standard text Engraved with standard text Engraved with standard text Engraved with standard text Engraved with standard text Engraved with standard text Engraved with standard text Engraved with standard text Enter country reference when ordering: D = German GB = English F = French I = Italian E = Spanish Label mounts, black, plug-in type

None None German/English Spanish French French German/English Italian Spanish Hungarian Portuguese Swedish Hungarian

Rotary switches T0, T3, P1 Switch-disconnectors T5(B), P3 Rotary switches T0, T3, P1 Switch-disconnectors T5(B), P3 Switch-disconnectors T5(B), P3 Rotary switches T0, T3, P1 Switch-disconnectors T5(B), P3 Rotary switches T0, T3, P1 Rotary switches T0, T3, P1 Switch-disconnectors T5(B), P3 Rotary switches T0, T3, P1 Rotary switches T0, T3, P1 Rotary switches T0, T3, P1

ZFS60-T0 019924 ZFS60-P3 022297 ZFS61/62-T0 030170 ZFS77-P3 047422 ZFS63-P3 047423 ZFS63-T0 047424 ZFS61/62-P3 065739 ZFS68-T0 065751 ZFS77-T0 065752 ZFS80-P3 205565 ZFS72-T0 205541 ZFS75-T0 205544 ZFS80-T0 205548 ZFS(*)-P5 105225

25 off

Switch-disconnector P5-.../EA/SVB Switch-disconnector P5-.../V/SVB

1 off

Rotary switches T0, T3, P1 Switch-disconnectors T5(B), P3 Insert plates

ZFSX-T0 024670 ZFSX-P3 027043

25 off 25 off

Rotary switches T0, T3, P1 Switch-disconnectors T5(B), P3

BS45X14-T0 029416 BS84X24-P3 031789

25 off 25 off

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

7/46
Rotary switches, switch-disconnectors

Ordering Key operation, locking interlock


S, SVA, SVC
Moeller HPL0211-2007/2008 For use with http://catalog.moeller.net Key withdrawal/locking option http://catalog.moeller.net Part no. Article no. Moeller HPL0211-2007/2008 Price see price list Std. pack Notes

Ordering Key operation, locking interlock


S, SVA, SVC

7/47
Rotary switches, switch-disconnectors

S-T0 key operated lock mechanism, Front IP53 Includes two keys KMS 1 lock mechanism Individual lock mechanism, not suitable for master key systems KMS 2-10 lock mechanisms, KMS 201-400 lock mechanisms: Individual lock mechanisms, not suitable for master key systems T0-.../E, .../I1, .../Z up to max. 6 contact units T3-.../E, .../Z up to max. 5 contact units T3-.../I2 up to max. 4 contact units P1-.../E, .../I2, .../Z Key withdrawal positions can be programmed by the user S-T0 086709 S-SOND-KMS(*)-T0 231957 1 off The key replaces the thumb-grip, cannot be switched without key. The switch position indication in on the lock. Normally the key is withdrawable in every position. With the ordering of a rotary switch with front plate FS908 together with key operation the key is only withdrawable in the 0 position. The key removability can be changed (also retro) with the locking cam "VR-T0". With retrofitting of key operation the existing front plate of the rotary switch must be used. Key a page 7/50

1 off

Lock KMS1: Switch with FS908 are possible as main switch for T0-1-... to T0-4-.../I1, .../E; T3-1-... to T3-4-.../I2; T3-1-... to T36-.../E; P1-.../I2, .../E SA(...) = Master key system (with master key) supplied with a security certificate. Order must include a lock plan showing the full configuration of the envisaged lock system. For subsequent part orders, simply state the item number within the lock plan, e.g. (A6294-1/2).

T0-.../E, .../I1, .../Z up to max. 6 contact units T3-.../E, .../Z up to max. 5 contact units T3-.../I2 up to max. 4 contact units P1-.../E, .../I2, .../Z

Key withdrawal positions are programmed ex-works as ordered

S(*)-T0 231959 S(*)-SOND-SA(*)-T0 231965

1 off

1 off

SVA-T3 cylinder lock, Front IP65 Includes two keys KMS 1 lock mechanism Individual lock mechanism, not suitable for master key systems KMS 2-10 lock mechanisms, KMS 201-400 lock mechanisms: Individual lock mechanisms, not suitable for master key systems T0-.../E, .../I1, .../Z T3-.../E, .../I2, .../Z P1-.../E, .../I2, .../Z Key withdrawal positions can be programmed by the user SVA-T3 050974 SVA-SOND-KMS(*)-T3 231967 1 off Switched with thumb-grip. Locked by turning the key. The key is removable. Normally all positions can be locked. Individual positions or ranges are lockable (also retro with VR-T3). In positions that are not lockable the key cannot be removed. With lockable ranges only inside the range can be switched without the key. The positions or ranges to be locked must be entered as follows in the form. Example 1: SVA(A)-T3 = only position A withdrawable Example 2: SVA(A, E)-T3 = only position A and E withdrawable Example 3: SVA(A-J)-T3 = range A to J withdrawable Example 4 SVA(S)-T3 = main switch for use as EmergencyStop according to IEC/EN 60204-1, VDE 0113 Part 1, with red thumb-grip and yellow front plate "Panic lock version" lockable in positions A and E, from E it can still be switched to A but not from A to E. The front plate of the switch is to be used for retroffitting. With the letter S use for panic lock FS908GE. Ordering example: P1-25/I2-RT+SVA(S)-T3

1 off

C B

D
330 300 315

E
0 30 45

G H

60 90

KMS1 lock mechanism: Switches with FS908 are suitable as main switches: T0-1-... to T0-4-.../I1, .../E; T3-1-... to T3-5-.../ I2; T3-1-... to T3-6-.../E; P1-.../I2, .../E SA(...) = Master key system (with master key) supplied with a security certificate. Order must include a lock plan showing the full configuration of the envisaged lock system. For subsequent part orders, simply state the item number within the lock plan, e.g. (A6294-1/2).

T0-.../E, .../I1, .../Z T3-.../E, .../I2, .../Z P1-.../E, .../I2, .../Z

Lockable positions can be programmed by the user

SVA(*)-T3 907745 SVA(*)-SOND-SA(*)-T3 231971

1 off

A R Q

270 240 225 135 210 180 150

J K

120

1 off

Ordering example for a master key system: SVA(A-G)-SOND-SA(A6294-1/2)-T3 Key a page 7/50

SVC-T3 padlocking feature, Front IP65 In the depressed position, the locking slide is lockable with up to 3 padlocks All positions are lockable T0-.../E, .../I1, .../Z T3-.../E, .../I2, .../Z P1-.../E, .../I2, .../Z T0-1-... to T0-4-.../I1, .../E T3-1-... to T3-5-.../I2 T3-1-... to T3-6-.../E P1-.../I2, .../E P1-.../I2, .../E Lockable positions can be programmed by the user Lockable positions are programmed ex- works as ordered SVC-T3 050975 SVC(*)-T3 907748 1 off Switched with thumb-grip. Interlocked by pushing a button that is lockable with 1-3 padlocks. Normally all positions can be lokked. By entering SCV(...)-T3 only the entered position is lockable. Locked ranges can only be switched within the range without removing the padlocks. The positions or ranges to be locked must be entered in the form. Form a Notes to SVA(...)-T3 The front plate of the switch is to be used for retroffitting. With the letter S use for panic lock FS908GE. Ordering example: P1-25/I2-RT+SVC(S)-T3

Specified positions or ranges are lockable

1 off

C B

D
330 300 315

E
0 30 45

G H

60 90

A R Q

270 240 225 135 210 180 150

J K

120

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

7/48
Rotary switches, switch-disconnectors

Ordering Neutral poles, auxiliary switches, central mounting accessories


N-P1, N-P3, N-P5
For use with Moeller HPL0211-2007/2008 Part no. Article no. http://catalog.moeller.net Price see price list Std. pack

Neutral poles Early-make, late-break For side mounting, left or right With P1-.../I2: optional N-P1Z or HI11-P1/P3Z can only be fitted to left P1-.../E, .../EA, .../EZ P1-.../Z, .../V, .../I2, .../IVS P3-.../E, .../EA... P3-.../Z, .../V, .../IVS P3-63/E,.../Z, /I4 P3-100/E, .../Z, .../I5 Neutral terminal For side mounting Protective conductor terminal For side mounting P5-250(315)/Z(V) N-P5-250/315Z 280972 PE-P5-125/160E 280973 PE-P5-250/315Z 280976 1 off N-P1E 000651 N-P1Z 000652 N-P3E 062432 N-P3Z 064805 5 off

P5-125(160)/E(EA) P5-250(315)/Z(V)

1 off

Auxiliary contacts Late making N/O and early breaking N/C contacts. The N/O is always connected as a load-shedding contact. For side mounting, left and/or right With P1-.../I2: HI11-P1/P3Z or N-P1Z can be fitted to left only Centre mounting accessories For single-hole fitting Mounting diameter 22.3 mm For rotary switches with existing front plate Mounting diameter 22.3 mm and 30.5 mm T0-.../E T3-.../E T0-.../E T3-.../E P1-.../E EZ-T0 081622 EZ-P1 091455 1 off 1 off P1-.../E, .../EA..., .../EZ P3-.../E, .../EA P1-.../Z, .../V, .../I2, .../IVS P3-63/Z, .../V, .../I4, .../IVS P3-100/Z, .../V, .../I5, .../IVS HI11-P1/P3E 061813 HI11-P1/P3Z 062031 5 off

Service distribution board mounting accessories Includes push-fit shaft For retrofitting T0-.../XZ basic switches as T0-.../IVS into service distribution boards T0-.../XZ IVS-T0 091114 1 off

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

Ordering Coupling drive, interlock parts, shaft extension


http://catalog.moeller.net Moeller HPL0211-2007/2008 For use with Type suffix/Type Article no., When ordered with basic unit/ ordered separately

7/49
Rotary switches, switch-disconnectors

DE-T0(P3), ZAV-T0(P3)
Price see price list Std. pack Notes

Coupling drive Includes push-fit shaft For retrofitting T0(T3)-.../XZ basic switches in the rear mounting form Spare parts for T0(T3)/(P1)-.../Z DE-T0 093487 1 off

For conversion of T5 (B)-.../E flush mounting switch into a rear mounting switch Spare parts for T5(B)/(P3)-.../Z

DE-P3 093972

3 off

Interlock sections With PE and N conductor connection Fits on the reverse of flush mounting switches, with interlocking function for rear mounting switches. T0-.../E, ...EZ, ...Z T3-.../E, ...EZ, ...Z P1-.../E, ...EZ, ...Z T5(B)-.../E, ...Z P3-.../E, ...Z

UV-T0 019925 UV-P3 048289

1 off

Fits on the reverse of flush mounting switches With interlocking function for rear mounting switches

Interlock extensions Up to four off, 25 mm each, can be plugged onto interlock section (An equal number of shaft extensions is required for this purpose) Use ZVV-T0 only with T0/T3- UV-T0 .../Z and P1-.../Z

ZVV-T0 022298

10 off

Use ZVV-T0 only with construction type T0/ T3-.../Z and P1-.../Z Use ZVV-P3 only with construction type T5(B)-.../Z and P3-.../Z

Use ZVV-P3 only with T5(B).../Z and P3-.../Z

UV-P3

ZVV-P3 024671

Shaft extensions Up to four off, 25 mm each, can be plugged onto switch shaft T0-.../Z, T0-.../V T3-.../Z, T3-.../V P1-.../Z, P1-.../V T5(B)-.../Z P3-.../Z Shaft Aluminium, length: 480 mm P5-.../V... P5-.../Z ZAV-P5 280979 1 off ZAV-T0 027044 ZAV-P3 029417 10 off

Interlock extensions und shaft extensions, complete Only available in conjunction with a basic unit Extension up to 25 mm when ordered with basic unit +ZAV(X1)+ZVV(X1)-T0/P3 254546 1 off

Control circuit terminal P5-250/315 ST-P5-250/315 280978 1 off Terminal capacity solid or stranded: 4 mm2 Flexible with ferrules to DIN 46228: 4 mm2

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

7/50
Rotary switches, switch-disconnectors

Ordering Shrouds, Keys


H
For use with Part no. Article no. Moeller HPL0211-2007/2008 Price see price list Std. pack http://catalog.moeller.net Notes

Shrouds For flush-mounting switches with up to 4 contact units T0-.../E T3-.../E H3-T0 093828 1 off Cable entries Quantity: 2 x o 20 mm + 2 x o 15 mm Cross-section: 5 x 6 mm2 5 x 2.5 mm2 Can be used for input and/or output wiring

Cover for protection of terminals For up to 2 contact units

T5(B)-.../E, .../Z

H1-T5 045062

Extension of H1-T5 cover To protect 3 to 8 contact units To cover terminals on 3-pole switch-disconnectors To cover terminals on 4-pole switch-disconnectors To cover terminals on 3-pole open switch-disconnectors with N neutral conductor and/or HI11 auxiliary contact modules fitted

H1-T5

HZ-T5 045063 H-P1 017253 H-P14 019626 H-P3 021999

10 off

1 x HZ-T5 required per contact unit Can be used for input and/or output wiring Can be used for input and/or output wiring The shroud is designed for fitting onto both sides of the switch-disconnector. Parts which are not required can be broken off.

P1-.../E, .../EZ, .../Z, .../EA, .../V P1-...N, ...HI11, ...N...HI11 P3-.../E, .../Z, .../ EA, .../V P3-...N, ...HI11, ...N...HI11

5 off

Set of three, to protect the terminals

P5

H-P5-125/160-3P 280967

3 off

Cover assembly to protect the 6 terminals

T8-3-8342/...

H-T8 200184

Keys For KMS 1 individual lock mechanism For KMS 2 - 10 individual lock mechanism or KMS 201 - 400 Individual key, corrosion-proof, for master key systems and recorded individual lock mechanisms: state lock plan no. and lock ES-KMS1-T0 231972 ES-KMS(*)-T0 231973 HS-SA(*)-T0 256151 10 off

Master keys must always be ordered separately. Please send or submit the security certificate with repeat orders. Ordering example:HSSA(A6294-1/2)-T0

Locking cams (2 cams per set) For user to select indexing position in which key can be withdrawn S-T0 for all switching angles VR-T0 089082 1 off

Mounting plate screen To connect the screeniing CI-K2 MBS-I2 290191 2 off

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

Ordering Insulated enclosures, accessories


http://catalog.moeller.net Moeller HPL0211-2007/2008 For use with Part no. Article no. Price see price list Std. pack Notes

7/51
Rotary switches, switch-disconnectors

IP65 insulated enclosures Enclosures designed for metric cable glands to EN 50262 1 2 contact units With pushthrough cable entry 3 - 4 contact units diaphragm. 1 2 contact units 5 contact units 3 - 4 contact units 1 2 contact units 3 - 4 contact units 1 2 contact units 3 - 4 contact units 5 contact units 1 2 contact units 3 - 4 contact units 1 2 contact units 3 - 4 contact units only available together with basic device only available together with basic device Neutral terminals For connection of 5th conductor CI-K2-PKZ0-... T5B-.../I4, Cl-K4-T5B-... P3-.../I4 CI-K4 T5-/I5, CI-K5-T5- P3-/I5 CI-K, 100 A T5-.../I5, CI-K5-T5-... P3-.../I5 CI-K5 Set of external fixing brackets T5B-.../I4, T5-.../I5, P3-63/I4, P3-100/I5, Set of extension terminals For retrofitting For cable connection in the enclosure For the lowest contact unit For the second contact unit from the bottom AB-CI-K4/5 206914 1 off For fixing CI-K4 and CI-K5 directly to the wall. One set comprises 4 brackets. K-CI-K1/2 207451 K-CI-K4 206916 20 off 20 off With metric knock-outs

T0-.../XZ T0-.../XZ T3-.../XZ T3-.../Z T3-.../XZ T0-.../XZ T0-.../XZ T3-.../XZ T3-.../XZ T3-.../XZ T5B-.../E T5B-.../Z T5-.../Z T5-.../Z T0-.../I1

CI-K1-T0-2 207435 CI-K1-T0-4 207436 CI-K2-T3-2 207437 CI-K2-T3-5 207438 CI-K2-T3-4 225325 CI-K1H-T0-2 105854 CI-K1H-T0-4 105855 CI-K2H-T3-2 269462 CI-K2H-T3-4 105859 CI-K2H-T3-5 105860 CI-K4-T5B-2 207439 CI-K4-T5B-4 207440 CI-K5-T5-2 207441 CI-K5-T5-4 207442 +I1H 105870 +I2H 105871

1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off

Cable sizes which may be pushed through the diaphragm Main-/control current 12 mm/ 16 mm/8 mm 1 contact unit = 2 contacts

Converts T5-.../Z into T5-.../I5 and T5B-.../E into T5B.../I4: Order AW-T5-... extension terminals in addition 1 contact unit = 2 contacts

T3-.../I2 P1-.../I2

1 off

K50/1 098573

10 off

K-CI-K5 218488

20 off

T5B-.../I4 T5-.../I5 T5-.../I5

AW-T5-1/2 032601 AW-T5-3/4 032602

10 off 1 off

Included with T5B-.../I4 and T5-.../I5 as standard. Included with T5B-.../I4 and T5-.../I5 as standard.

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

7/52
Rotary switches, switch-disconnectors

System overview Mini rotary switches


TM
Moeller HPL0211-2007/2008 http://catalog.moeller.net

ON-OFF switches TM

2 10

9 9

8 7 8

8 8 6 8
Control switch TM

6 6 4 4 4 3

2 10 11 9 9 11

HA

O ND

AU TO

6 6 6 4 4 4 3

0 1

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

System overview Mini rotary switches


http://catalog.moeller.net Moeller HPL0211-2007/2008 1 Centre mounting (.../EZ) Front IP 65 Mount in fixing hole 16.2 o or 22.3 o according to IEC/EN 60947-5-1 after removing provided the adapter a page 7/54 Key operation for centre mounting 2 keys are supplied Key withdrawable 90 Key withdrawable 60 with RONIS lock cylinder. a page 7/59 Can be used with up to 250 V AC per contact Maximum 6 contacts permissible a page 7/54 3, 4 2

7/53
Rotary switches, switch-disconnectors

TM
Standard switch for centre mounting 5, 6 Black thumb-grip a page 7/54 Control circuit isolator Red rotary handle and yellow locking collar Black rotary handle and black locking collar Lockable in the 0 position a page 7/54 Standard switch for flush mounting Black thumb-grip a page 7/55 Standard switch for distribution 11 board mounting IVS Mounting in service distribution board Mounting width: 2 TE (45 mm mounting depth) up to 2 contact units 9, 10 7, 8

Flush mounting (.../E) Front IP 65 Mounting from rear in walls, plates or doors Terminals: Crosshead screwdriver Pozidrive Fingerproof a page 7/54

Flush mounting control circuit isola- 1 tor (.../E/SVB) Front IP 65 To IEC/EN 60947-5, VDE 0660 0 position lockable with 2 padlocks 4 mm o or 1 padlock 6 mm o

Product features Contact chamber Rated uninterrupted current 10 A Gold plated contacts for safe switching of small voltages and currents also in agressive atmospheres -Positively opening contacts 1 2 contacts per switching chamber (BE), up to 16 contacts per switch For switching differing potentials Control circuit reliability Switch postion Safety due to latching Switching angle 30, 45, 60, 90 Spring action with automatic return with max. 6 contacts, switching angle f 60 Complete rotation With a total switching angle of 360 complete rotation is possible in both directions

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

7/54

Ordering Control circuit isolators, On-Off switches


TM
Moeller HPL0211-2007/2008 Front plate no. No. of poles Design Protection type Part no. Article no. Price see price list Std. pack http://catalog.moeller.net

Contact sequence

Mini rotary switches

Control circuit isolators, 90 With padlocking facility, lockable in the Off position Up to 250 V AC per contact 1
0 1 1 2

Flush mounting Flush mounting

Front IP65 Front IP65 Front IP65 Front IP65 Front IP65 Front IP65 Front IP65 Front IP65

TM-1-8290/E/SVB-SW 215351 TM-1-8290/E/SVB 045477 TM-1-8291/E/SVB-SW 215352 TM-1-8291/E/SVB 045478 TM-2-8292/E/SVB 045484 TM-2-8292/E/SVB-SW 210955 TM-2-8293/E/SVB 045485 TM-3-8326/E/SVB 045498

1 off

0 1

2
1 2 3 4

Flush mounting Flush mounting

0 1

3
1 2 3 4 5 6

Flush mounting Flush mounting

0 1

3+N
1 2 3 4 5 6 7 8

Flush mounting Flush mounting

0 1

6
1 2 3 4 5 6 7 8 9 10 11 12

On-Off switches, 90
0 1

1 0
1 2

Centre mounting

Front IP65

TM-1-8290/EZ 000693

1 off

F 056

Flush mounting
0 1

Front IP65 Front IP65

TM-1-8290/E 070131 TM-1-8291/EZ 015073

2
1 2 3 4

Centre mounting

Flush mounting
0 1

Front IP65 Front IP65 Front IP65

TM-1-8291/E 072504 TM-2-8292/E 074877 TM-2-8292/EZ 015096

3
1 2 3 4 5 6

Flush mounting Centre mounting

0 1

3+N
1 2 3 4 5 6 7 8

Flush mounting Centre mounting

Front IP65 Front IP65

TM-2-8293/E 077250 TM-2-8293/EZ 045486

0 1

6
1 2 3 4 5 6 7 8 9 10 11 12

Flush mounting

Front IP65

TM-3-8326/E 079623

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

Ordering Changeover switch, hand/automatic switch


http://catalog.moeller.net Contact sequence Moeller HPL0211-2007/2008 Front plate no. No. of poles Design Protection type Part no. Article no.

7/55

TM
Price see price list Std. pack

Changeover switches
1 2

F 072

1 2 2 3

Flush mounting Centre mounting Flush mounting Centre mounting Flush mounting Centre mounting Flush mounting Centre mounting Flush mounting Flush mounting

Front IP65 Front IP65 Front IP65 Front IP65 Front IP65 Front IP65 Front IP65 Front IP65 Front IP65 Front IP65

1 2 3 4 5 6 7 8 9 10 11 12

3 4

1 2

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

4 5 5

1 2

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

1 2

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

1 0 2

With 0 position, 60

1 1 2 2

Centre mounting Flush mounting Centre mounting Flush mounting Centre mounting Flush mounting Flush mounting Centre mounting Flush mounting Flush mounting

Front IP65 Front IP65 Front IP65 Front IP65 Front IP65 Front IP65 Front IP65 Front IP65 Front IP65 Front IP65

1 0 2

1 2 3 4 5 6 7 8

1 2 3 4

F 071

1 0 2

3 3 3

F 249
1 2 3 4 5 6 7 8 9 10 11 12

1 0 2

4 4
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

TM-1-8210/EZ 015137 TM-1-8210/E 096234 TM-2-8211/EZ 015166 TM-2-8211/E 098607 TM-3-8212/EZ 045491 TM-3-8212/E 010807 TM-3-8299/E 020299 TM-4-8213/EZ 045847 TM-4-8213/E 013180 TM-2-8219/E 017926 TM-1-8214/E 032164 TM-2-8215/E 034537

1 0 2

0 1 2

With 0 position, 90 With springreturn from both directions, 30

1 2 3 4 5 6 7 8

F 057
1 0 2

Flush mounting

Front IP65

F 025

1 2 3 4

Flush mounting

Front IP65

Hand-Auto switches, 60
AUTO HAND
HAND AUTOM

1 2 3 4 5 6 7 8

Centre mounting

Front IP65

F 288
HAND

1 2 3 4

TM-18220F288/EZ 016925 TM-1-15431/E 025045 TM-1-15431/EZ 000691 TM-1-15431/IVS 225342 TM-2-15432/EZ 016878 TM-2-15432/E 027418 TM-3-15433/EZ 045490 TM-3-15433/E 029791

1 off

AUTO 0 HAND

AUTO

1 1 1

Flush mounting Centre mounting Service distribution board mounting Centre mounting Flush mounting Centre mounting Flush mounting

Front IP65 Front IP65 Front IP30

F 085
1 2 3 4

AUTO 0 HAND

2 2
1 2 3 4 5 6 7 8

Front IP65 Front IP65 Front IP65 Front IP65

AUTO 0 HAND

3 3
1 2 3 4 5 6 7 8 9 10 11 12

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

Mini rotary switches

Without 0 position, 60

Centre mounting

Front IP65

TM-1-8220/EZ 000692 TM-1-8220/E 081996 TM-2-8221/EZ 015197 TM-2-8221/E 084369 TM-3-8222/EZ 045493 TM-3-8222/E 086742 TM-4-8223/EZ 046119 TM-4-8223/E 089115 TM-5-8369/EZ 046126 TM-5-8369/E 091488 TM-6-8370/E 093861

1 off

1 2

1 2

1 2 3 4 5 6 7 8

1 2 3 4

7/56

Ordering Control switch, step switch


TM
Moeller HPL0211-2007/2008 Front plate no. No. of poles Design Protection type Part no. Article no. http://catalog.moeller.net Price see price list Std. pack

Contact sequence

Mini rotary switches

Step switches Without 0 (Off) position 3 steps, 60


1 2 3

2 1

1 1 3 3

Flush mounting Centre mounting Flush mounting Centre mounting

Front IP65 Front IP65 Front IP65 Front IP65

F 076

4 steps, 60
1 2 3 4

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18

TM-2-8230/E 039283 TM-2-8230/EZ 000701 TM-5-8270/E 041656 TM-5-8270/EZ 046124 TM-2-8231/E 044029 TM-2-8231/EZ 000700 TM-6-8271/E 046402 TM-6-8271/EZ 046128 TM-3-8232/E 039298 TM-3-8232/EZ 015592 TM-5-8252/E 041671 TM-5-8252/EZ 046123

1 off

1 2 3

1 2 3 4 5 6

2 1

3 4

1 1

Flush mounting Centre mounting Flush mounting Centre mounting

Front IP65 Front IP65 Front IP65 Front IP65

F 077
1 2 3 4 5 6 7 8

1 2 3 4

3 3
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

5 steps, 60
1 2 3 4 5

2 1

3 4 5

1 1 2 2

Flush mounting Centre mounting Flush mounting Centre mounting

Front IP65 Front IP65 Front IP65 Front IP65

F 078
1 2 3 4 5 6 7 8 910

2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

6 steps 60, no full rotation


1 2 3 4 5 6

2 1 6

3 4 5

1 1

Flush mounting Centre mounting

Front IP65 Front IP65

F 079
1 2 3 4 5 6 7 8 9 10 11 12

TM-3-8233/E 053521 TM-3-8233/EZ 015630 TM-6-8253/E 055894 TM-6-8253/EZ 046127

2 2
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

Flush mounting Centre mounting

Front IP65 Front IP65

10 steps, 30
2 1 345

1 1

Flush mounting Centre mounting

Front IP65 Front IP65

6 7 8 10 9

F 011

TM-5-8237/E 069150 TM-5-8237/EZ 015661

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

Ordering Control switch, step switch


http://catalog.moeller.net Contact sequence Moeller HPL0211-2007/2008 Front plate no. No. of poles Design Protection type Part no. Article no.

7/57

TM
Price see price list Std. pack

With additional 0 (Off) position 2 steps, 60


0 1 2

1 0

1 1 2 2

Flush mounting Centre mounting Flush mounting Centre mounting Flush mounting Centre mounting

Front IP65 Front IP65 Front IP65 Front IP65 Front IP65 Front IP65

F 075
0 1 2
1 2 3 4

0 1 2

3 3

TM-1-8240/E 058267 TM-1-8240/EZ 015226 TM-2-8260/E 060640 TM-2-8260/EZ 045483 TM-3-8280/E 063013 TM-3-8280/EZ 045496 TM-2-8241/E 065386 TM-2-8241/EZ 015256 TM-3-8261/E 067759 TM-3-8261/EZ 000698 TM-5-8281/E 070132 TM-5-8281/EZ 046125

1 off

3 steps, 45
0 1 2 3

1 2 3 4 5 6 7 8 9 10 11 12

1 2 3 4 5 6 7 8

1 2 3 0

1 1 2 2

Flush mounting Centre mounting Flush mounting Centre mounting Flush mounting Centre mounting

Front IP65 Front IP65 Front IP65 Front IP65 Front IP65 Front IP65

1 off

F 109
1 2 3 4 5 6

0 1 2 3

1 2 3 4 5 6 7 8 9 10 11 12

0 1 2 3

3 3
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18

4 steps, 30
0 1 2 3 4

1 0

234

1 1 2 2

Flush mounting Centre mounting Flush mounting Centre mounting Flush mounting Centre mounting

Front IP65 Front IP65 Front IP65 Front IP65 Front IP65 Front IP65

F 002
1 2 3 4 5 6 7 8

TM-2-8242/E 072505 TM-2-8242/EZ 015506 TM-4-8262/E 074878 TM-4-8262/EZ 046120 TM-6-8282/E 077251 TM-6-8282/EZ 046129

1 off

0 1 2 3 4

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

0 1 2 3 4

3 3
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

5 steps, 30
0 1 2 3 4 5

1 0

2 34

1
5

Flush mounting Centre mounting

Front IP65 Front IP65

F 003
1 2 3 4 5 6 7 8 9 10

TM-3-8243/E 079624 TM-3-8243/EZ 015537

1 off

6 steps, 30
0 1 2 3 4 5 6

1 0

2 34

5 6

1 1

Flush mounting Centre mounting

Front IP65 Front IP65

F 004

TM-3-8244/E 081997 TM-3-8244/EZ 045495

1 off

9 steps, 30
1 0 2 3 4 98 5 6 7

1 2 3 4 5 6 7 8 9 10 11 12

1 1

Flush mounting Centre mounting

Front IP65 Front IP65

F 007

TM-5-8247/E 009741 TM-5-8247/EZ 015565

1 off

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18

Mini rotary switches

Step switches

7/58

Ordering Control switches: group switches (OFF) spring-return switch, reversing switches, coding switches
TM
Moeller HPL0211-2007/2008 Front plate no. Design Protection type Part no. Article no. http://catalog.moeller.net Price see price list Std. pack

Contact sequence

Mini rotary switches

Group switches 2 groups, 60


2 1 0

1 0

Flush mounting Centre mounting

Front IP65 Front IP65

F 075

TM-1-8310/E 084370 TM-1-8310/EZ 045479 TM-2-8311/EZ 045487

1 off

3 groups, 30
2
1 0 2 3

1 2 3 4

Centre mounting

Front IP65

F 001
0

ON (OFF) switch On switch 30


START I
START

1 2 3 4 5 6

Centre mounting

Front IP65

TM-1-8175/EZ 015690

1 off

1 2

F 023

ON-OFF switch 90/30 with spring-return from Start to 1


START 1 0
1 START 0

Flush mounting Centre mounting

Front IP65 Front IP65

F 119

TM-1-8178/E 098608 TM-1-8178/EZ 016786

Reversing switches 60 Degree


0 2
1 0 2

1 2 3 4

Flush mounting

Front IP65

TM-3-8401/E 015554

1 off

F 071

Coding switches BCD code 0-9, 30


1 0 2 3 4 98 5 6 7

1 2 3 4 5 6 7 8 9 10

Flush mounting Centre mounting

Front IP65 Front IP65

F 007

TM-2-8550/E 020300 TM-2-8550/EZ 000699

1 off

2 3 4 5 6 7 8

BCD code 0-9 + complement, 30


1 0 2 3 4 98 5 6 7

Flush mounting

Front IP65

TM-4-8552/E 025046

F 007

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

Ordering Locks, front plates


http://catalog.moeller.net Protection type Moeller HPL0211-2007/2008 Key withdrawable with Part no. suffix Article no. Price see price list Std. pack Notes

7/59

EZ/S-

Key operation Includes two keys For service distribution board mounting (IVS) when ordered with basic unit KABA lock 90 IP65 IP65 IP65 RONIS lock 60 IP55 IP55 IP55 IP55 0 270 + 0 270 270 + 330 + 30 + 90 + 150 + 210 270 + 90 270 + 330 + 90 + 150 300 + 0 + 60 + 120 + 180 + 240 +EZ/S-A 045458 +EZ/S-F 045463 +EZ/S-B 045459 +EZ/S-J 045466 +EZ/S-D 045461 +EZ/S-N 045468 +EZ/S-H 045465 1 off

Options for key withdrawal

A H

B J

C M

D N

E P

F Q

G R

Postion marking for the example


330 300 315 270 240 225 210 180 0 30 45 60 90 135 120 150

Size

Dimensions (W x H x D) mm

Part no. Article no.

Std. pack

Notes

Standard front plates TM.../EZ 29 x 29 (for frame size 30 x 30) 29 x 29 (for frame TM.../E size 30 x 30) Blank plates Can be engraved TM 29 x 29 (for frame size 30 x 30) TM 29 x 29 (for frame size 30 x 30)

TM/EZ-FRONTSCHILD-NR(*) 239022 TM/E-FRONTSCHILD-NR(*) 239021

1 off 1 off

Standard front plates For standard contact sequence the normal front plate can be replaced if required with the front plate shown here. This is provided the switching angle, number of positions and the position of the 0 position are the same. Switching angle 30

FS980-TM-E 071438 FS980-TM-EZ 073811

10 off 50 off

START

STOP

START

1 0 2

MAN

OFF

AUTO

1 0

AUTO

HAND

AUTO

MAN

AUTO

OFF

HAND

F023
1 0 23

F024
1 0 234

F025
1 0 234 5

F039
1 0 234 5 6

F053
1 0 234 5 6 7

F258
1 0 234 8 5 6 7

F259
1 0 234 98 5 6 7

F708
2 1 345 10 9 6 7 8

F001

F002

F003

F004

F005

F006

F007

F011

Switching angle 45
0 1 2 1 0 2 1 2 3 2 2 3 0
OFF

1 0

1
OFF

2 1

1 2

1 2

1 2

1 2

F215
1 0 2 3 4

F216
2 1 3 4 5

F738
2 1 3 0 1 2 3

F109
1 2 3 7 4 5 6

F115
L1-L2 L2-L3 L3-L1

F330
L1-L2 L2-L3 L3-L1

F105
1 2 8 3 7 4 5 6

F113
0 1 7 2 6 5 3 4

L1-N L2-N L3-N

L1-L2 L2-L3 L3-L1

F293

F741

F106

F110

F785

F788

F111

F322

Switching angle 60
1 2
AUTO MAN AUTO HAND

1 0

2 1

HAND

AUTO

F072
2 0 1

F234
MAN

F288
AUTO OFF HAND

F071
2 1 3 4

F073
1 0 2 3

F075
2 1 5 3 4

F076
2 1 6 5 3 4

F085
START

AUTO

START

F249

F373

F732

F077

F102

F078

F079

F121

Switching angle 90
1 0
OFF ON AUS EIN

0 1 2
MAN

OFF AUTO

2 1 3

F056
0 3 2 1

F063
1 4 3 2

F068
0 1 0 1

F700
OFF ON OFF ON

F743
2 1 4 3

F057
0
NETZ NOTSTROM

F209
1 0
START

F719

F059

F060

F062

F206

F718

F437

F119

F990

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

Mini rotary switches

Key operated lock mechanism including two keys. The key can be withdrawn only in specified positions, see diagrams below. However, the KABA lock mechanism for 90 can also be used for other switching angles provided the positions for key withdrawal correspond with those specified for the Type of switch. Example: +EZ/S-B can be used on a step switch having a switching angle of 30, provided the key is to be withdrawn only in the Off position at 270.

7/60

System overview Small enclosures


CI-K
Moeller HPL0211-2007/2008 http://catalog.moeller.net General Degree of protection IP65 (except CI-K2-80-A) Five basic sizes (floor area of enclosure base) Two mounting depths per base surface (exception: CI-K1 enclosure depth always 95 mm, CI-K2-80-. enclosure depth always 80 mm) Enclosure made of glass-fibre reinforced with self-extinguishing polycarbonate, halogen free Captive gasket Enclosure base (RAL 9005) Black (matt) Enclosure cover RAL 7035, light grey (matt) Metric cable entries 1 CI-K1 and CI-K2 metric cable entry knockouts with push-through cable entry diaphragm in the sides, top and bottom and also in the rear wall CI-K1H, CI-K2H: metric cable entry knockouts in the enclosure sides, top and bottom CI-K3 to CI-K5: metric cable entry knockouts in the sides, top and bottom and also in the rear wall Control cable entry from CI-K2 Metric cable glands to EN 50 262 Push-through metric cable grommets a page 7/63, a page 13/35 Mounting systems for empty enclosures 2 Mounting rails to IEC/EN 60715 Sheet steel mounting plates Accessories for mounting systems a page 7/64 Mounting 3 Horizontal and vertical slot apertures for wall-mounting enclosures Captive cover screws CI-K1 and CI-K2 with rubber feet on the back plate to compensate for uneven walls External mounting brackets for CI-K4 and CI-K5 a page 7/51 Mounting units Miniature circuit-breakers Rotary switch Switch-disconnectors Contactors easy control relays Timing relays Control circuit devices Laser labelling We can label the cover surface of the CI-K small enclosures according to your specifications. Wipe-resistant and permanent with modern laser labelling method. Please contact your sales office. CI-K combination-* a page 7/62 Approved enclosures for use in UL/CSA a page A1/40 Cutouts in enclosure covers We can produce cutouts in enclosure covers to your requirements. Please contact your sales office.

Small enclosures, empty enclosures

1 1

3 3

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

Ordering Basic enclosures


http://catalog.moeller.net Dimensions Moeller HPL0211-2007/2008 Features

7/61

CI-K1, CI-K2, CI-K3


Part no. Article no. Price see price list Std. pack

Enclosure depth: Dimensions from top 1. Mounting depth for mounting plate 2. Mounting depth for mounting rails, 7.5 mm height 3. Enclosure depth

mm

mm

CI-K basic enclosures Degree of protection IP65 (Exception: CI-K2-80-A), material glass-fibre reinforced polycarbonate Enclosure base RAL 9005, black/enclosure top RAL 7035, light grey Metric cable entry knockouts top, bottom and in the back plate Push-through cable membrane on CI-K1 and CI-K2 Hard metric knockouts for sizes CI-K1H and CI-K2H Hard metric knockouts from sizes CI-K3 to CI-K5 Two protective covers to protect the push-through cable membrane with CI-K1 and CI-K2 Control cable entry from CI-K2 Lamp indicator L-. can be mounted in base knock-out M20/M25 With mounting rail L
72

L 80
M

82 120

With mounting rail

CI-K1-95-TS 206881 CI-K1H-95-TS 105853

1 off

95

With mounting rail


79

116 160

73

With mounting rail With mounting plate

Q 100 M
124
116 160
100

With mounting plate With mounting rail


118

With mounting rail With mounting plate

Q 100
145

With mounting plate With adapter plate Prepared for fitting a DILE contactor with ZE overload relay With adapter plate Prepared for fitting a DILE contactor with ZE overload relay

CI-K2-100-TS 206882 CI-K2H-100-TS 229304 CI-K2-100-M 206893 CI-K2H-100-M 229306 CI-K2-145-TS 206883 CI-K2H-145-TS 229305 CI-K2-145-M 206894 CI-K2H-145-M 229307 CI-K2-145-AD 207632 CI-K2H-145-AD 229308 CI-K3-125-TS 206884 CI-K3-125-M 206895

N
98

With mounting rail With mounting plate

152 200

93

R 120 N
133
152 200

125

With mounting rail With mounting plate

128

CI-K3-160-TS 206885 CI-K3-160-M 206896

R 120
160

Notes

Number and size of cable entries a page 7/63

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

Small enclosures, empty enclosures

7/62

Ordering Basic enclosures


CI-K4, CI-K5
Moeller HPL0211-2007/2008 Features Part no. Article no. http://catalog.moeller.net Price see price list Std. pack Enclosure depth: Dimensions from top 1. Mounting depth for mounting plate 2. Mounting depth for mounting rails, 7.5 mm height 3. 7.5 mm mounting depth with mounting rails

Small enclosures, empty enclosures

Dimensions

mm CI-K basic enclosures

mm

Degree of protection IP65 (Exception: CI-K2-80-A), material glass-fibre reinforced polycarbonate Enclosure base RAL 9005, black/enclosure top RAL 7035, light grey Metric cable entry knockouts top, bottom and in the back plate Push-through cable membrane on CI-K1 and CI-K2 Hard metric knockouts for sizes CI-K1H and CI-K2H Hard metric knockouts from sizes CI-K3 to CI-K5 Two protective covers to protect the push-through cable membrane with CI-K1 and CI-K2 Control cable entry from CI-K2 Lamp indicator L-. can be mounted in base knock-out M20/M25 With mounting rail O
98

With mounting plate

194 240

CI-K4-125-TS 206886 CI-K4-125-M 206897

1 off

93

O 160
125

With mounting rail


133 128

With mounting plate

CI-K4-160-TS 206890 CI-K4-160-M 206898

160

98

234 280

93

With mounting rail (weight of fitted components max. 0.65 kg, with additional mounting plate 1.7 kg) With mounting plate

CI-K5-125-TS 206891

CI-K5-125-M 206899

P 200
125

With mounting rail (component weight max. 0.65 kg, with additional mounting plate 1.7 kg)
133 128

CI-K5-160-TS 206892

With mounting plate

CI-K5-160-M 206900

160

Customized cutouts and laser inscriptions Only with enclosure cover The necessary data (laser data, symbols, text and their respective positions) as well as the position of the cutouts must be provided as a DXF file. CI-K1-COMBINATION-* 102060 CI-K2-COMBINATION-* 102061 CI-K3-COMBINATION-* 102062 CI-K4-COMBINATION-* 102063 CI-K5-COMBINATION-* 102064 Notes Number and size of cable entries a page 7/63 1 off

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

Ordering Basic enclosures


http://catalog.moeller.net Dimensions Moeller HPL0211-2007/2008 Enclosure depth: Dimensions from top 1. Enclosure depth 2. Mounting depth for mounting plate 3. Mounting depth for mounting rail, 7.5 mm height Features Part no. Article no.

7/63

CI-K2
Price see price list Std. pack

mm Basic enclosure CI-K2

mm

Degree of protection IP30, glass-fibre reinforced polycarbonate material Enclosure base RAL 9005, black/enclosure top RAL 7035, light grey Metric cable entry knockouts top, bottom and in the back plate Push-through cable entry diaphragm with CI-K2 Hard metric knockouts on CI-K2H Two protective covers to protect the push-through cable membrane with CI-K2 Control cable entry L-... indicator lights can be fitted in M20/M25 knockout in base with cover cutout Standard cutout dimensions and mounting M rail for devices requiring 2 to 4 space units. T Push-through cable entry membrane. 46 Close off unused space units (max. 2) using blanking strips VST1, a page 7/65
Q 100
160

CI-K2-80-A 211107

1 off

80

with hinged cover

Standard cutout dimensions and mounting rail for devices requiring 2 to 4 space units. Hard metric knockouts. Close off unused space units (max. 2) using blanking strips VST1, a page 7/65 Transparent hinged cover for devices requiring 2 to 4 space units. Push-through cable entry diaphragm. Transparent hinged cover for devices requiring 2 to 4 space units. Hard metric cable entry knockouts.

CI-K2H-80-A 229309

1 off

M T
160

with cover cutout


70

CI-K2-80-K 211108

1 off

Q 100
80 115

with hinged cover

CI-K2H-80-K 229310

1 off

Notes L

Membrane grommets, cable glands a page 13/35 M N O P Q R

Knockouts 2 x M20 or pushthrough membrane up to max. o 12 mm

Knockouts Knockouts 2 x M25 or push2 X M25/20 through membrane up to max. o 16 mm CI-K2H: 2 x M25/20

Knockouts 2 X M32/25 1 X M20

Knockouts 2 X M50/40/25 1 X M20

Knockouts Knockouts 2 x M25 or push2 X M25/20 through membrane up 1 X M20 to max. o 16 mm and 1 push-through membrane up to o 8 mm CI-K2H: 2 x M25/20

Back plate: 2 x push-through membrane up to max. o 8 mm

Back plate: Back plate: 2 x push-through mem- 2 X M25/20 brane up to max. o 11 mm (not for CI-K2H)

Back plate: 2 X M32/25

Back plate: 2 X M50/40/25

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

Small enclosures, empty enclosures

7/64

Ordering Accessories
TS-CI, M-CI
Moeller HPL0211-2007/2008 Mounting position Features Useful length mm Part no. Article no. http://catalog.moeller.net Price see price list Std. pack For use with

Small enclosures, empty enclosures

Mounting rails to IEC/EN 60715 Height 7.5 mm, with fixing screws

7.5

CI-K1 CI-K2 CI-K3 CI-K4 CI-K5

Crosswise Crosswise Lengthwise and crosswise Crosswise Lengthwise and crosswise, CI-K4 lengthwise

60 82 98 133 173

TS-CI-K1 206901 TS-CI-K2 206902 TS-CI-K3 206903 TS-CI-K4 206904 TS-CI-K5 206905

10 off

Mounting plates 2 mm steel with fixing screws

CI-K2 CI-K3 CI-K4 CI-K5 Accessories for mounting systems Spacers For raising mounting systems in CI-K3 to CI-K5 (4 off required for mounting plate, 2 off required for mounting rail) Hank nuts To secure devices to mounting plate
7

M-CI-K2 206906 M-CI-K3 206907 M-CI-K4 206908 M-CI-K5 206909

10 off

by 25 mm by 50 mm by 10 mm by 15 mm

HS25-CI 002291 HS50-CI 002292 ADT200-190 002289 ADT125-110 002290

25 off 25 off 10 off 10 off

M4 thread M5 thread

BT7488 088380 BT7477 086007

100 off 100 off

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

Ordering Accessories
http://catalog.moeller.net Moeller HPL0211-2007/2008 For use with For use with Terminal capacities flexible mm2 Part no. Article no.

7/65
Rotary switches, switch-disconnectors

K-CI, SK-CI
Price see price list Std. pack

Accessories for CI-K small enclosures External fixing bracket kit To secure CI-K4 and CI-K5 directly on the wall. Each kit contains 4 brackets. T5B-.../I4, T5-.../I5, P3-63/I4, P3-100/I5, Mounting rail adapter, screw fixing To secure enclosure on mounting rails to IEC/EN 60715 CI-K1

AB-CI-K4/5 206914

1 off

TB-CI-K 206918

1 off

Blanking strips To blank off one space unit; cannot be removed from outside CI-K2-80-A

VST1 211258

5 off

N terminals, PE terminals Can be screwed onto support bosses in enclosure base plate CI-K2-PKZ0-... CI K1/2

1 4 mm2

K-CI-K1/2 207451

20 off

Insulated individual terminals With PE, N adhesive labels For snap-fitting onto mounting rail CI-K3 T5B-.../I4, Cl-K4-T5B-... P3-.../I4 CI-K5 T5-.../I5, CI-K5-T5-... P3-.../I5 Protective covers for push-through cable membrane with CI-K1(2) To cover the push-through cable membrane CI-K1 (M20) CI-K1 (M25) CI-K4 1 10 mm2 1.5 16 mm2 K-CI-K3 206915 K-CI-K4 206916 K-CI-K5 218488 20 off 20 off

10 35 mm2

20 off

SK-CI-K1 226766 SK-CI-K2 226767

100 off 100 off

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

7/66

Ordering Accessories
CI
Moeller HPL0211-2007/2008 Features For use with Enclosure depth mm Part no. Article no. Price see price list Std. pack http://catalog.moeller.net Dimensions mm

Small enclosures, empty enclosures

CI-B, C, D basic enclosures Transparent cover Metric knockouts top, bottom With PEN terminal IP55 individual enclosure with pre-drilled mounting plate DIL00AM L
149 110

CI-B 024315

5 off

L
87

128

Knockouts 2 X M20

L
165

S27
110

CI-C 031434

2 off

L
110

128

DIL0AM S27
222 110

CI-D 038553

2 off

L
110

128

Hank nuts To secure devices to mounting plate M4 thread


7

BT7488 088380 BT7477 086007

100 off

M5 thread PE terminal (5th conductor) Rated current 25 A For o 1.5 6 mm2 solid

100 off

CI-B CI-C CI-D

K6/1 002270

100 off

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

Technical data Switch-disconnectors


http://catalog.moeller.net Moeller HPL0211-2007/2008 P1-25 General Standards Lifespan, mechanical Maximum operating frequency Climatic proofing Ambient temperature Mounting position Mechanical shock resistance (IEC/EN 60068-2-27) Contacts Rated operational voltage Rated impulse withstand voltage Overvoltage category/pollution degree Rated uninterrupted current Load rating with intermittent operation, class 12 Open Enclosed Half-sinusoidal shock, 20 ms Operations Operations/h x 106 P1-32

7/67
Rotary switches, switch-disconnectors

P1, P3
P3-63 P3-100

C C g

IEC/EN 60 947, VDE 0660, IEC/EN 60 204, CSA,UL Switchdisconnectors to IEC/EN 60 947-3 0.3 0.3 0.1 0.1 50 50 50 50 Damp heat, constant, to IEC 60068-2-78; Damp heat, cyclical, to IEC 60068-2-30 -2550 -2550 -2550 -2550 -2540 -2540 -2540 -2540 As required As required As required As required 15 15 15 15

Ue Uimp Iu

V AC V AC A x Ie x Ie x Ie A gG/gL Arms V AC V AC Number W mm2 mm2

AB 60 % DF AB 40 % DF AB 25 % DF Short-circuit rating Fuse Rated short-time withstand current (1 s current) Isolating characteristics to IEC/EN 60947 Safe isolation to VDE 0106 Part 101 and Part 101/A1 Safe isolation to VDE 0106 Part 101 and Part 101 A1 between auxiliary contacts and main contacts Switching angles Contacts Current heat loss per contact at Ie Terminal capacities Solid or stranded Flexible with ferrule to DIN 46228 Terminal screw Tightening torque Switching capacity Alternating voltage Rated making capacity cos v = 0.35 Rated breaking capacity, motor load switch cos v = 0.35

Icw

690 6000 III/3 25 1.3 1.6 2 25 640 690 440 90 max. 3 (+N) 1.1 1 x (1.5 6) 2 x (1.5 6) 1 x (1 4) 2 x (1 4) M4 1.6

690 6000 III/3 32 1.3 1.6 2 50 640 690 440 90 max. 3 (+N) 1.8 1 x (1.5 6) 2 x (1.5 6) 1 x (1 4) 2 x (1 4) M4 1.6

690 6000 III/3 63 1.3 1.6 2 80 1260 690 440 90 max. 3 (+N) 4.5 1 x (2.5 35) 2 x (2.5 10) 1 x (1.5 25) 2 x (1.5 6) M5 3

690 6000 III/3 100 1.3 1.6 2 100 2000 690 440 90 max. 3 (+N) 7.5 1 x (2.5 35) 2 x (2.5 10) 1 x (1.5 25) 2 x (1.5 6) M5 3

Nm

230 V 400/415 V 500 V 690 V Rated operational current 440 V load-break switch AC-21A AC-3 motor load switch motor rating 230 V 400/415 V 500 V 690 V AC-23A Motor load switches (main 230 V switches maintenance switches) 400/415 V 500 V 690 V DC DC-1, Load-break switches L/R = 1 ms Rated operational current Voltage per contact pair in series DC-23A, motor load switch 24 V Rated operational current L/R = 15 ms Contacts 48 V Rated operational current Contacts 60 V Rated operational current Contacts 120 V Rated operational current Contacts Notes

Ie P P P P P P P P Ie Ie Ie Ie Ie

A A A A A A kW kW kW kW kW kW kW kW A V A Quantity A Quantity A Quantity A Quantity

240 190 150 170 150 25 5.5 7.5 7.5 7.5 7 13 11 11 25 60 25 1 25 2 25 3 12 3

320 260 300 290 250 32 7.5 13 18.5 15 8.5 15 18.5 18.5 32 60 25 1 25 2 25 3 12 3

800 640 600 590 340 63 15 30 30 30 18.5 37 37 30 63 60 50 1 50 2 50 3 25 3

950 760 740 880 520 100 22 37 45 37 30 50 65 45 100 60 50 1 50 2 50 3 25 3

Main switch characteristics to IEC/EN 60204; positive opening of contacts, operator element positively located on shaft The rated uninterrupted current Iu is stated at max. connected cross-section. For terminal capacity solid, stranded and flexible: Max. 2 cross-section sizes difference admissible when using 2 conductors.

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

7/68
Rotary switches, switch-disconnectors

Technical data Switch-disconnectors


P5
Moeller HPL0211-2007/2008 P5-125 P5-160 P5-250 http://catalog.moeller.net P5-315

General Standards Lifespan, mechanical Maximum operating frequency Climatic proofing Ambient temperature Mounting position Contacts Rated operational voltage Rated impulse withstand voltage Overvoltage category/pollution degree Rated uninterrupted current Load rating with intermittent AB 60 % DF operation, class 12 AB 40 % DF AB 25 % DF Short-circuit rating Fuse Rated short-time withstand current (1 s current) Isolating characteristics to IEC/EN 60947 Safe isolation to VDE 0106 Part 101 and Part 101/A1 Safe isolation to VDE 0106 Part 101 and Part 101 A1 between auxiliary contacts and main contacts Switching angles Contacts Current heat loss per contact at Ie Terminal capacities Solid or stranded Copper band, 1 band Number of segments x width x thickness Ue Uimp Iu V AC V AC A x Ie x Ie x Ie A gG/gL Arms V AC V AC Number W mm2 mm Open Enclosed Operations Operations/h x 106

IEC/EN 60947, VDE 0660, IEC/EN 60204, CSA, UL switch disconnector according to IEC/EN 60947-3 0.1 0.1 0.08 0.08 50 50 50 50 Damp heat, constant, to IEC 60068-2-78; Damp heat, cyclical, to IEC 60068-2-30 -2550 -2550 -2550 -2550 -2540 -2540 -2540 -2540 As required As required As required As required 690 8000 III/3 125 1.3 1.6 2 125 2500 690 440 90 max. 3 (+N) 8 1 x (10 95) 2 x (10 35) 6 x 9 x 0.8 690 8000 III/3 160 1.3 1.6 2 160 3000 690 440 90 max. 3 (+N) 10 1 x (10 95) 2 x (10 35) 690 8000 III/3 250 1.3 1.6 2 250 4600 690 440 90 max. 3 (+N) 13 1 x (16 185) 2 x (16 70) 6 x 20 x 1 690 8000 III/3 315 1.3 1.6 2 315 5800 690 440 90 max. 3 (+N) 16 1 x (16 185) 2 x (16 70)

C C

Icw

Copper band, 2 bands Flexible with ferrule to DIN 46228 Terminal screw Tightening torque Notes

mm mm2

Nm

1 x (16 70) 2 x (16 25) Allen screw 5 14

6 x 9 x 0.8 1 x (16 70) 2 x (16 25) Allen screw 5 14

1 x (25 120) 2 x (25 50) Allen screw 6 16

6 x 9 x 0.8 1 x (25 120) 2 x (25 50) Allen screw 6 16

Main switch characteristics to IEC/EN 60204; positive opening of contacts, operator element positively located on shaft The rated uninterrupted current Iu is stated at max. connected cross-section. For terminal capacity solid, stranded and flexible: Max. 2 cross-section sizes difference admissible when using 2 conductors.

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

Technical data Switch-disconnectors, auxiliary contacts


http://catalog.moeller.net Moeller HPL0211-2007/2008 P5-125 Switching capacity Alternating voltage Rated making capacity cos v = 0.35 Rated breaking capacity, motor load 230 V switch cos v = 0.35 400 V 500 V 690 V Rated operational current 440 V load-break switch AC-21A AC-3 motor load switch motor rating 230 V 400 V 690 V AC-23A Motor load switches (main 230 V switches maintenance switches) 400 V 690 V DC DC-1, Load-break switches L/R = 1 ms Rated operational current DC-1, Load-break switches L/R = 1 ms Voltage per contact pair in series DC-23A, motor load switch L/R = 15 ms 24 V 48 V 60 V 120 V Rated operational current Contacts Rated operational current Contacts Rated operational current Contacts Rated operational current Contacts P5-160

7/69
Rotary switches, switch-disconnectors

P5
P5-250 P5-315

Ie P P P P P P Ie

A A A A A A kW kW kW kW kW kW A V A Quantity A Quantity A Quantity A Quantity

850 800 750 650 340 125 22 37 30 30 45 37 125 42 125 3 125 3 125 3 40 3

1050 900 850 850 340 160 30 45 37 30 55 37 160 42 160 3 160 3 160 3 50 3

1700 1600 1380 1250 400 250 37 55 45 37 90 45 250 42 250 3 250 3 250 3 80 3

2050 1800 1650 1550 400 315 45 75 45 55 110 45 315 42 315 3 315 3 315 3 100 3

Ie Ie Ie Ie

Notes

Main switch characteristics to IEC/EN 60204; positive opening of contacts, operator element positively located on shaft The rated uninterrupted current Iu is stated at max. connected cross-section. For terminal capacity solid, stranded and flexible: Max. 2 cross-section sizes difference admissible when using 2 conductors.

HI...-P1(P3)... Auxiliary contacts Standards Rated insulation voltage Rated uninterrupted current Rated operational current AC-15 with 230 V 380 V/415 V DC-13 125 V 250 V Short-circuit rating Maximum fuse Terminal capacities Solid Flexible with ferrule to DIN 46228 Tightening torque Control circuit reliability at 24 V DC, 10 mA Ui Iu Ie Ie Ie Ie V AC A A A A A A gG/gL mm2 mm2 Nm HF

HI...-P5...

Control circuit isolators to IEC/EN 60947-5f 500 10 6 500 10 6 3 0.23 0.1 10

1.1 0.55 10

Fault probability

0.75 2.5 0.75 2.5 0.5 1.5 0.5 2.5 0.6 0.8 < 10 -5, < 1 fault in 100 000 operations

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

7/70
Rotary switches, switch-disconnectors

Technical data Rotary switch


T
Moeller HPL0211-2007/2008 T0-... http://catalog.moeller.net T3-... http://catalog.moeller.net T5B-... T5-... Moeller HPL0211-2007/2008 T6-3-8212/E/HI12 T6-160-... T8-...

Technical data Rotary switch


T

7/71
Rotary switches, switch-disconnectors

General Standards

Lifespan, mechanical Maximum operating frequency Climatic proofing Ambient temperature Open Enclosed Mounting position Mechanical shock resistance to IEC 60068-2-27 Contacts Rated operational voltage Rated impulse withstand voltage Overvoltage category/pollution degree Rated uninterrupted current open Enclosed Load rating with intermittent operation, class 12 AB 25 % DF AB 40 % DF AB 60 % DF Short-circuit rating Fuse Rated short-time withstand current (1 s current) Safe isolation to VDE 0106 Part 101 and Part 101/A1 between the contacts Switching angles

Operations Operations/h

x 106

IEC/EN 60947, VDE 0660, IEC/EN 60204, CSA, UL Switch-disconnectors to IEC/EN 60947-3 Load-break switches to IEC/EN 60947-3 1 0.5 3000 3000 Damp heat, constant, to IEC 60068-2-78; Damp heat, cyclical, to IEC 60068-2-30 2550 2540 As required > 15 2550 2540 As required > 15

IEC/EN 60947, VDE 0660, IEC/EN 60204, CSA, UL Switch-disconnectors to IEC/EN 60947-3 Load-break switches to IEC/EN 60947-3 0.5 0.5 0.1 0.1 3000 3000 50 50 Damp heat, constant, to IEC 60068-2-78; Damp heat, cyclical, to IEC 60068-2-30

0.1 50

C C Half-sinusoidal shock 20 ms Ue Uimp g

2550 2540 As required > 15

2550 2540 As required > 15

2550 2540 As required

2550 2540 As required

2550 2540 As required

V AC V AC

690 6000 III/3 20 20 2 1.6 1.3 20 320 440 90 60 45 30 11 max. 22 0.6 1 x (1 2.5) 2 x (1 2.5) 1 x (0.75 1.5) 2 x (0.75 1.5)

690 6000 III/3 32 32 2 1.6 1.3 35 650 440 90 60 45 30 11 max. 22 1.1 1 x (1 6) 2 x (1 6) 1 x (0.75 4) 2 x (0.75 4)

690 6000 III/3 63 63 2 1.6 1.3 80 1300 440 90 60 45 30 10 max. 20 4.5 1 x (2.5 35) 2 x (2.5 16) 1 x (1.5 25) 2 x (1.5 10)

690 6000 III/3 100 100 2 1.6 1.3 100 1850 440 90 60 45 30 10 max. 20 7.5 1 x (2.5 35) 2 x (2.5 16) 1 x (1.5 25) 2 x (1.5 10)

690 6000 III/3 125 125 2 1.6 1.3 200 2000

690 8000 III/3 160 160 2 1.6 1.3 160 3000

690 8000 III/3 315 275 2 1.6 1.3 315 4200

Iu Iu

A A x Ie x Ie x Ie A gG/gL Arms V AC

Icw

90 60

90 60

90 60

Contact units Double-break contacts Current heat loss per contact at Ie Terminal capacities Solid or stranded Flexible with ferrule to DIN 46228 Flat conductor connection with busbars Terminal screw Tightening torque Notes

W mm2 mm2 mm2

3 max. 6 11 1 x 70 2 x 25 1 x 50 2 x 16

3 max. 6 11 1 x 95 2 x 25 1 x 50 2 x 16

3 max. 6 11 150 120 1 x (25 x 5) 2 x (20 x 3) M12 25

Nm

M3.5 1

M4 1.6

M6 4

M6 4

M6 5.6

M5, Allen key 14

For mechanical shock resistance: T3.../I... >12g Applies to T0(3).../SVB: isolating characteristics to IEC/EN 60947 Ufor rated operational voltage up to 500 V AC Applies to rated uninterrupted current Iu of the contact: with T5-4-8344/I5 max. 95 A For terminal capacity solid, stranded and flexible: T0(3), (6), (8)...: Maximum of 2 cross-section sizes difference admissible between 2 conductors T5(B)-...: Maximum of 1 cross-section size difference admissible between 2 conductors For type T8-3-8342/... the following applies: switching angle = 90 and flat connection = 1 busbar 25 x 5 or 2 busbars 20 x 3

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

7/72
Rotary switches, switch-disconnectors

Technical data Rotary switch


T
Moeller HPL0211-2007/2008 T0-... http://catalog.moeller.net T3-... http://catalog.moeller.net T5B-... T5-... Moeller HPL0211-2007/2008 T6-3-8212/E/HI12 T6-160-... T8-...

Technical data Rotary switch


T

7/73
Rotary switches, switch-disconnectors

Switching capacity Alternating voltage Rated making capacity cos v = 0.35 Rated breaking capacity, motor load switch cos v = 0.35

230 V 400 V 500 V 690 V Rated operational current 440 V load-break switch AC-21A 230 V AC-3 motor load switch motor rating 230 V Star-delta 400/415 V 400 V Star-delta 500 V 500 V Star-delta 690 V 690 V Star-delta AC-23A Motor load switches (main 230 V switches maintenance switches) 400/415 V 500 V 690 V Rated operational current control switch 230 V AC-15 400/415 V 500 V DC-1, Load-break switches L/R = 1 ms DC-21A Rated operational current Voltage per contact pair in series Rated operational current 240 V

Ie P P P P P P P P P P P P Ie Ie Ie Ie Ie

A A A A A A kW kW kW kW kW kW kW kW kW kW kW kW A A A A V A Quantity A Quantity A Quantity A Quantity A Quantity A Quantity A V HF

130 100 110 80 60 20 3 4 4 5.5 5.5 7.5 4 5.5 3.5 6.5 13 6 4 2 10 60 1

320 260 260 240 170 32 6.5 11 12 18.5 15 22 15 22 7.5 13 15 10 6 4 25 60 1

800 520 600 480 340 63 15 22 22 37 22 37 22 37 15 22 22 22 16 6 4 63 60

950 760 740 590 420 100 22 30 30 45 37 55 30 45 18.5 30 37 30 16 6 4 80 60

1600 1280 900 880 340 125 22 22 37 37 37 37 22 22 37 45 55 30 125 42

1600 1280 900 880 340 160 22 22 45 45 37 37 22 22 37 55 55 30 125 42

2390 1910 1800 1200 420 315 22 37 55 55 37 37 37 37 75 132 75 37 315 42

DC

240 V Contacts Rated operational current Contacts 48 V Rated operational current Contacts 60 V Rated operational current Contacts 120 V Rated operational current Contacts 240 V Rated operational current Contacts Rated operational current DC-13, Control switches L/R = 50 ms Voltage per contact pair in series Control circuit reliability at 24 V DC, 10 mA DC-23A, motor load switch L/R = 15 ms 24 V Auxiliary contacts Standards Rated insulation voltage Rated uninterrupted current Rated operational current AC-15 with 230 V 380 V/415 V Short-circuit rating Maximum fuse Terminal capacities Solid Flexible with ferrule to DIN 46228 Tightening torque Control circuit reliability at 24 V DC, 10 mA

Ie Ie Ie Ie Ie Ie Fault probability

1 1 10 25 1 1 10 25 2 2 10 25 3 3 5 12 3 3 5 5 5 5 10 20 32 32 < 10 -5, < 1 fault in 100000 operations

50 1 50 2 50 3 25 3 20 6 25 24 < 10 -5, < 1 fault in 100000 operations

125 1 125 2 125 3 50 3 125 24

125 1 125 2 125 3 50 3 125 24

250 1 250 2 125 3 50 3 250

Ui Iu Ie Ie

V AC A A A A gG/gL mm2 mm2 Nm HF

Control circuit isolators to IEC/EN 60947-5f 500 500 10 10 6 4 10 0.75 2.5 0.5 1.5 6 4 10 0.75 2.5 0.5 1.5

Fault probability

0.35 0.35 < 10-5, < 1 fault in 100 000 operations

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

7/74

Technical data Mini rotary switches


TM
Moeller HPL0211-2007/2008 TM http://catalog.moeller.net

General Standards

Mini rotary switches

IEC/EN 60947, VDE 0660 UL, CSA Control switches to IEC/EN 60947-5-1 Control circuit isolators to IEC/EN 60947-5-1 Maximum 6 contacts; switching angle 90 1 3000 Damp heat, constant, to IEC 60068-2-78; Damp heat, cyclical, to IEC 60068-2-30 2550 2540 As required 1 x 1,5 2 x 1,5 1 x 1,5 2 x 1,5 1 x 14 2 x 14 1 x 16 2 x 16 M2.5 0.35

Control circuit isolators (IEC/EN 60947-5-1) Lifespan, mechanical Maximum operating frequency Climatic proofing Ambient temperature Open Enclosed Mounting position Terminal capacities Solid Flexible without ferrule Solid or stranded Flexible Terminal screw Tightening torque Contacts Mechanical variables Contacts Contact units Switching angles

Operations Operations/h

x 106

C C

mm2 mm2 AWG AWG

Nm

Number

Min. switching angle for On-Off-On Max. number of switch positions Thickness of gold coating Electrical characteristics Rated operational voltage Rated impulse withstand voltage Overvoltage category/pollution degree Rated insulation voltage Rated insulation voltage for UL/CSA Rated uninterrupted current

mm Ue Uimp Ui Iu V AC V AC V AC V AC A

Max. 16 8 90 60 45 30 60 F 12 35 500 4000 III/3 500 300 10

Switching capacity AC-23 Motor load switches

AC-15 Control switches

230 V AC, 3-pole 440 V AC, 3-pole 230 V AC, 1-pole 440 V AC, 1-pole 230 V AC, 1-pole

kW kW kW kW A A A A A A

1.8 3 0.75 1.1 2.5 1.5 1 10 0.7 0.3 3

400 V AC, 1-pole 440 V AC, 1-pole DC-1 Load-break switches 1 24 V DC 110 240 V DC DC-13, Control switches L/R = Rated operational current 50 ms Voltage per contact pair in series 240 V AC, 3-pole 277 V AC, 1-pole 300 V AC Heavy duty Max. short-circuit protective device Fuse Control circuit reliability at 24 V DC, 10 mA Switching capacity (UL489, CSA 22.2 No. 5.1)

Ie

V HP HP A A gG/gL HF

32 1 o 10 10 < 10-5, < 1 fault in 100000 operations

Fault probability

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

Technical data Small enclosures


http://catalog.moeller.net Moeller HPL0211-2007/2008 CI-K1 General Standards CI-K2 CI-K3

7/75

CI-K
CI-K4 CI-K5

Climatic proofing Ambient temperature Ambient temperature with push-through cable entry Protection type Degree of protection with push-through cable entry Dissipatable heat loss Material characteristics Material Base, Cover Surface treatment Colour Base Cover Material properties Electrical Creepage resistance to IEC 60112 Base Cover Surface resistance to IEC 60093 Dielectric strength to IEC 60243-1 Thermal Continuous thermal stability Enclosures Gasket Mechanical IK code to EN 50102 Weight of components fitted per mounting rail with mounting plate Chemical resistance Base, Cover Resistant Partially resistant Not resistant Push-through membrane (CI-K1/CI-K2) and sealing material Resistant Partially resistant Not resistant Atmospheric Saline spray UV resistance Water consumption to DIN EN ISO 62 Flammability characteristics Glow wire test Base, Cover Glow wire to VDE 0471 Part 2 to UL 94 Push-through membrane (CI-K1/CI-K2) and sealing material To IEC 2 to UL 94 Halogen free C C

IEC/EN 60529 DIN 43660 EN 50262 Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 2570 2540 IP 65 IP 65 IP 65 IP 65 IP 65 IP 65 a Chapter 14, Technical data

IP 65 IP 65

IP 65 IP 65

Glass-fibre reinforced polycarbonate Resistant to corrosion RAL 9005, black (matt) Enclosure cover RAL 7035, light grey (matt)

O x 1013 kV/mm

CTI175 CTI175 1 30

C C

-40120 -4080 Please enquire

kg kg

0.2

0.7

0.85 0.85

0.75 0.9

0.65 1

Acids < 10 %, mineral oil, petrol, grease, saline solution Acids > 10 %, alcohol Alkalis, benzol Acids < 10 %, alkalis, alcohol, saline solution Acids < 10 %, grease, benzol Mineral oil, petrol IEC 60068-2-11 Beneath protective shield 0.29 0.29

0.29

0.29

0.29

Thickness 960/1 mm VO/1.5 mm thick

650/1 mm thick HB Yes

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

Small enclosures, empty enclosures

7/76
Rotary switches, switch-disconnectors

Dimensions Rotary switch


T0, T3
Moeller HPL0211-2007/2008 http://catalog.moeller.net

Flush mounting T0.../E (+ H3-T0) T3.../E (+ H3-T0)


H3-T0

Drilling dimensions

3.1 3.5 5 10 11 12.2 3.2 1.5 5 24.1 +0.4 0 22.3


+0.4 0

b
17

25

101

90

48 c20 35 75

Centre mounting T0.../EZ T3.../EZ Drilling dimensions T0 T3

b
17

48

45 48

48

48 c21 35

48

61

Part no. c20 c21 T0-1... 41 61 T0-2... 50 70 T0-3... 60 80 T0-4... 69 89 T0-5... 79 99 T0-6... 88 108 T0-7... 98 118 T0-8... 107 127 T0-9... 117 137 T0-10... 126 146 T0-11... 136 156 One contact unit depth 9.5 mm

Part no. c20 c21 T3-1... 44 64 T3-2... 56 76 T3-3... 67 87 T3-4... 79 99 T3-5... 90 110 T3-6... 102 122 T3-7... 113 133 T3-8... 125 145 T3-9... 136 156 T3-10... 148 168 T3-11... 159 179 One contact unit depth 11.5 mm

Not included as standard Service distribution board mounting T0.../IVS Drilling dimensions base

c22 5 55 48 5

45 55

54

45

60

50

M4

54

28

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

50

30

Dimensions Rotary switches


http://catalog.moeller.net Rear mounting T0.../Z T3.../Z Extension possible with ZAV-T0 F 4 x 25 = 100 mm Moeller HPL0211-2007/2008 Drilling dimensions base
5 17 5

7/77
Rotary switches, switch-disconnectors
12.2

T0, T3
Drilling dimensions door

T0

O5

22.

5 5.5
+0 0 .4

a
50 60 M4 50

48

48

25

48 O5

36

T3

O5

22.

5 5.5
+0 0 .4

c23 36 36 O5 c24 38, 54


R

35
100

55

65 75

65

M4

63

Part no.

c20

c21

c22

c23 48 57 67 76 86 95 105 114 124 133 143

T0-1... 41 61 77 T0-2... 50 70 87 T0-3... 60 80 96 T0-4... 69 89 106 T0-5... 79 99 115 T0-6... 88 108 125 T0-7... 98 118 134 T0-8... 107 127 144 T0-9... 117 137 154 T0-10... 126 146 163 T0-11... 136 156 173 One contact unit depth 9.5 mm Not included as standard Flush mounting main switch T0.../EA/SVB T3.../EA/SVB

c24 f/F 86 102 96 112 105 121 115 131 124 140 134 150 143 159 153 169 162 178 172 188 181 197

c24 with F 4 ZAV 202 212 221 231 240 250 259 269 278 288 297

c25 72 72 91 91

Part no.

c20

c21

c22

c23 51 63 74 86 97 109 120 132 143 155 166

T3-1... 44 64 80 T3-2... 56 76 92 T3-3... 67 87 103 T3-4... 79 99 115 T3-5... 90 110 126 T3-6... 102 122 138 T3-7... 113 133 149 T3-8... 125 145 161 T3-9... 136 156 172 T3-10... 148 168 184 T3-11... 159 179 195 One contact unit depth 11.5 mm

c24 f/F 86 105 101 115 112 128 124 139 135 151 147 162 158 174 170 185 181 196 193 208 204 219

c24 with F 4 ZAV 205 216 228 239 251 262 274 285 296 308 319

Drilling dimensions door


F5

b
48
17

T0
45

36

c25 79 79 101 101

3.1 3.5

OFF

33

ON

49

OFF

T3
25 c20 35 61
54

65

Rear mounting main switch T0.../V/SVB T3.../V/SVB

Drilling dimensions base


5 F5 5 25

Drilling dimensions door


22. 3
5 5.5
+0 .4 0

b
48 17

T0
50 M4 50 60

OFF

33

ON

OFF

49 5 c23 c24 f 38, F 54 35

36

65

T3
65 75

1 Rf

a
63

Interlock extension possible with ZVV-T0 + ZAV-T0, F 4 x 25 = 100 mm Not included as standard

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

65

00

M4

36

10 11

30

7/78
Rotary switches, switch-disconnectors

Dimensions Rotary switches


T0, T3
Moeller HPL0211-2007/2008 http://catalog.moeller.net

Surface mounting T0.../I1 Drilling dimensions base


M4

137

120

M20 127

80

c25

27

T3.../I2

Drilling dimensions base


M4

180

160

M20 / M25

100

c25

c33

Surface mounting main switch T0.../I1/SVB

Drilling dimensions base


M4

137

o
OFF

OFF

120

80

c25

35

T3.../I2/SVB F 3 padlocks
d b

Drilling dimensions base


M4

d = 4 8 mm b + d F 47 mm

ON

180

OFF

OFF

160

M20 /M25

100

c25

35

Part no. T0-1... T0-2... T0-3... T0-4...

c25 75 75 95 95

Part no. T3-1... T3-2... T3-3... T3-4... T3-5...

c25 80 80 100 100 145

c33 27 27 35 35 35

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

171

127

M20
ON

171

Dimensions Rotary switches, switch-disconnectors, accessories


http://catalog.moeller.net Key operation S-T0 S-SOND...-T0 T0.../E(I1) + S-(SOND-)T0 T3.../E(I2) + S-(SOND-)T0 T0.../Z + S-(SOND-)T0 T3.../Z + S-(SOND-)T0 Moeller HPL0211-2007/2008

7/79
Rotary switches, switch-disconnectors

T0, T3, P1, P3


T0.../EZ T0../E + EZ-T0 + S-(SOND-)T0 T3.../EZ T3../E + EZ-T0 + S-(SOND-)T0
25

b
17 48

5 19 36 30

5 27 44
R

27 48

100

c20

22:25 28 30:23 26

3.1 3.5

22

.3

5 5.5
+0 0 .4

10...11

30

3.2

12.5

36

3.2

12.2

36
22.3 + 0.4
0

30.5

Cylinder lock SVA-T3 T0.../I1/SVA T3.../I2/SVA P1.../12/SVA T0.../E/SVA... T3.../E/SVA... P1.../E/SVA


56 56

T0.../Z/SVA... T3.../Z/SVA... P1.../Z/SVA


56

73

73

48

46

30

46

30

73

46

30

Padlocking feature SVC-T3 T0.../I1/SVC T3.../I2/SVC P1.../12/SVC T0.../E/SVC... T3.../E/SVC... P1.../E/SVC


56 56

T0.../Z/SVC... T3.../Z/SVC... P1.../Z/SVC


56

73

48 73

73

48

48

46

46

46

Modules Switched neutral N-P... Auxiliary contact HI 11-P1/P3


a33 a3 H-P...
5 L3 L2 3 L1 1 1 3 N N 2 4 6 5

F 3 padlocks
d b

HI 11

T3 6

T2 4

T1 2

N-P a31 a32 a32 a31

a32

a32

Part no. P1-... P3-..

a3 49 72

a31 15 18

a32 15 15

a33 83 114

b31 49 60

Not included as standard

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

b31

d = 4 8 mm b + d F 47 mm

48

73

73

17

7/80
Rotary switches, switch-disconnectors

Dimensions Rotary switches


T5B, T5
Moeller HPL0211-2007/2008 http://catalog.moeller.net Drilling dimensions door
18 4.1 4.5 27
I
ON

Flush mounting T5(B).../E

12 13 88 86

o
OFF

37

14 88 F5 c2 37

Rear mounting T5(B).../Z

Drilling dimensions base

Drilling dimensions door

a b
27 c20 F5 5 5.5

I o
OFF

ON

88

73

25 88 c2 f 38, F 54

25 37 48

R f 100

Shaft extension possible with ZAV-P3 F 4 x 25 = 100 mm Flush mounting main switch T5(B).../EA/SVB
88

Drilling dimensions door


F5 c2

b
27

25

4.1 4.5 12 13

I
OFF

ON

80/90

80/90

OFF

88

88

37

44

14

40.5 16.5

100

Rear mounting main switch T5(B).../V/SVB

Drilling dimensions base


F5 c20 5

Drilling dimensions door

b
27

I ON

88

OFF

25 88

25 44 48

a
12 16.5 40.5

R f 100

Part no.

c20 f/ F T5(B)-1... 54 92 107 T5(B)-2... 71 109 124 T5(B)-3... 87 125 140 T5(B)-4... 104 142 157 T5(B)-5... 120 158 173 T5(B)-6... 137 175 190 T5(B)-7... 153 191 206 T5(B)-8... 170 208 223 T5(B)-9... 186 224 239 T5(B)-10... 203 240 356 One contact unit depth 16.5 mm

c2

c20 with F 4 ZAV 207 224 240 257 273 290 306 323 339 356

c21 90 90 123 123

c22 125 (95) 125 (95) 160 (160) 160 (160)

Extension possible with ZVV-P3, F 4 x 25 = 100 mm Not included as standard

Rotary switches T5B and T5 are same size, only thier contacts are different

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

73

48

o OFF

48 5 5.5

M6

30 .5 .5 30

Dimensions Rotary switches


http://catalog.moeller.net Surface mounting T5B.../I4 T5.../I5 Moeller HPL0211-2007/2008

7/81
Rotary switches, switch-disconnectors

T5B, T5

240

280

M25 M32 M20

M25 M50 M20

160

c22

29

200

c22

37

Surface mounting main switches T5B.../I4/SVB


M5

Drilling dimensions F 3 padlocks


d b d = 4 8 mm b + d F 47 mm 240

I o
OFF

ON

OFF

193 142 c22 44

160

T5.../I5/SVB

Drilling dimensions
M5

ON

280

OFF

OFF

233 182 200 c22 44

External fixing bracket AB-CI-K415


7.8 3.8

Part no. c22 T5(B)-1... 125 T5(B)-2... 125 T5(B)-3... 160 T5(B)-4... 160 One contact unit depth 16.5 mm Rotary switches T5B and T5 are same size, only thier contacts are different

t=3
5.5 20

M5
6.5

6 52

36

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

7/82
Rotary switches, switch-disconnectors

Dimensions Rotary switches


T6, T8
Moeller HPL0211-2007/2008 http://catalog.moeller.net

Flush mounting T6-3-8212/E/HI12 T8.../E/HI12

a2

b2

58

150 c2

5 c30

T6-160-6/V/SVB-SW/HI11
6.4 2 H-T6-100

T8-3-8342/V/SVB-SW/HI11
7 H-T8 19

118

108

68

88

76 224

93 216 200 73

9
104 5.5 1
0 R 10

4.5 172.8 315 218 9.2 86.5 7 1


0 R 10

130 250

Part no.

a2

b2 88 130

c2 152 173

c30 44 62

d1 26 30 22 25 26 30

d2

x1

y1 68 104 68

Drilling dimensions door


d2

T6-3-8212/E/HI12 88 T8.../E/HI12 130 T8.../SVB

6.0 68 7.0 104 7.0 68

d1 x1

T6: 4 M5 x 20 T8: 4 M6 x 20

F 3 padlocks for T.../SVB


d b

d = 4 8 mm b + d F 47 mm

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

y1

130

68

Dimensions Switch-disconnectors
http://catalog.moeller.net Flush mounting Moeller HPL0211-2007/2008 Drilling dimensions Door P1-.../E
10 11 3.1 3.5 b22
5 3 1

7/83
Rotary switches, switch-disconnectors
28 55 45

P1, P3

Centre mounting

P.../E

P1.../EZ

P1-.../EZ
3.2 12.5 4.1 4.5

I 0
OFF

ON

L3 b2

L2

L1

12 13 b3 30 37 12.2 22.3 +0.4 0

T3
6

T2
4

T1
2

a2

a3 c2

5 c21

14

P1.../EZ = c2 + 5 mm

Service distribution board mounting P3.../IVS


5
L1 L2 L3

F 3 padlocks
c3 c23 c22
d

P1.../IVS
5 c3

a32
L1 L2 L3

a32

L1

L2

L3

d = 4 8 mm b + d F 47 mm

HI11
b3 45

N
T1 T2 T3

T1

T2

T3

a4

a31

T1

T2

T3

49

Rear mounting Drilling dimensions Bottom P1/Z


5 65 M4 36 22.3
+0.4 0

Door
5 5.5

P/Z

b22

b3 c31 c32 5

36 b2

P3/Z
5 5.5

a2

a3

75

c25 c20 38, 54

c21
100

25

48

Shaft extension possible with ZAV-... F 4 x 25 = 100 mm

Part no. P1 P3

a2 48 87

a3 49 72

a4 53.5 71.5

a21 65 87

a22 48 87

a23 87 125

a31 15 18

a32 15 15

a33 83 114

b2 48 87

b3 70 83

b21 65 87

b22 17 27

b23 180 175

48

M4

b3

.5 30

b24 32

b31 49 60

Part no.

c2

c3

c20 f/ F 96 112 103 118

P1 P3

59 59

86 82

c20 with F 4 ZAV/ZVV 212 218

c21

c22

c23

c24

c25

c27

c28

c31

c32

c33

35 37

32 41

65 63

68 81

58 65

35 44

77 90

25 25

25 25

27 29

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

7/84
Rotary switches, switch-disconnectors

Dimensions Switch-disconnectors
P1, P3
Moeller HPL0211-2007/2008 Drilling dimensions Door P1 http://catalog.moeller.net

Flush mounting main switches

P/EA/SVB
a22

P3

b
H-P...
b22

3.1 3.5
5 3 y 1

4.1 4.5
10 11

I o
OFF

ON

b31

b21

12 13
37

OFF

30

b3

12.2 a21 a3 F5 25 c2 c27

14

Rear mounting main switches Drilling dimensions Bottom P1/V/SVB Door


5 5.5

P/V/SVB

b
a22
b22

5 H-P...

F5

c27

65

M4

22.3 b31
1 3 5

+0.4 0

36
N

I o
OFF

ON

b21

b3

P3/V/SVB
5 5.5

OFF

a21

a3

75

f 38, F 54

Rf

Interlock extension possible with ZVV-...+ZAV... F 4 x 25 = 100 mm Not included as standard Layout P1.../I2

25

48

Surface mounting main switches/safety switches P1.../I2/SVB P1.../I2/SI Drilling dimensions

48

c25 c20

100

M4

36

30 .5

M4

M25 F8 160 b23 M25

M25 171 c27

a23

c28

c33

Part no. P1.../I2

a2 48

a3 49

a4 53.5

a21 65

a22 48

a23 100

a31 15

a32 15

a33 83

b2 48

b3 70

b21 65

b22 17

b23 180

b24 35.5

b31 49

Part no.

c2

c3

c20 f/ F 96 112

P1...

59

86

c20 with F 4 ZAV/ZVV 212

c21

c22

c23

c24

c25

c27

c28

c31

c32

c33

35

32

65

68

58

35

80

25

25

27

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

Dimensions Switch-disconnectors
http://catalog.moeller.net Flush mounting P5.../E
F5 M5

7/85
Rotary switches, switch-disconnectors
6
q 88 q 68

Moeller HPL0211-2007/2008

P5
Drilling dimensions

68

88

q 88

6 26 30
a c 8 35

Flush mounting main switches P5-.../EA/SVB(-SW)


M5 HI10

b2

68

88

88

b2

F5 a1 a2 a a2 21 c 26 49.3

Rear mounting P5.../Z


6.4
2

q 88

b1

F5
2

a1 a

c c1

35

Rear mounting main switches P5-.../V/SVB(-SW)

b2

b2

F5

26

Rf
a2 a a2 c c1 49.3

100

Part no. P5-125/160 P5-250/315

a 112 145

a1 36 44

a2 38 52.5

b 108 126

b1 120 144

b2 76 88

c 91 98

c1 f 130 f 140

F 287 F 280

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

88

q 88

q 68

Drilling dimensions

26 30

7/86
Rotary switches, switch-disconnectors

Dimensions Switch-disconnectors
P3
Moeller HPL0211-2007/2008 http://catalog.moeller.net Surface mounting main switches/safety switches P3-63/I4/SVB Drilling dimensions P3-63/I4/SI T5B-.../I4/SI
M5

Layout P3-63/I4

M25 M32

M20
193

b23

142

a23

95

29

95

44

Layout P3-100/I5

Surface mounting main switches/safety switches P3-100/I5/SVB Drilling dimensions P3-100/I5/SI T5-.../I5/SI
M5

M25 M50

M20

b23

233 182 a23 125 37 125 44

Part no. P3-63/I4 P3-100/I5

a2 87 87

a3 72 72

a4 71.5 71.5

a21 87 87

a22 87 87

a23 160 200

a31 18 18

a32 15 15

a33 114 114

b2 87 87

b3 83 83

b21 87 87

b22 27 27

b23 240 280

b24 35.5 35.5

b31 60 60

Part no.

c2

c3

c20 f/ F 103 118 103 118

P3-63 P3-100

59 59

82 82

c20 with F 4 ZAV/ZVV 218 218

c21

c22

c23

c24

c25

c27

c28

c31

c32

c33

37 37

41 41

63 63

81 81

65 65

44 44

125 125

25 25

25 25

37 37

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

Dimensions Mini rotary switches


http://catalog.moeller.net Flush mounting TM.../E
3 4.8 8 M3 M3 3.2

7/87
Rotary switches, switch-disconnectors
3.2 22.3
+0.4 0

Moeller HPL0211-2007/2008

TM
Drilling dimensions

30

28

28

20 28 c20

30

Control circuit switches for 2 padlocks 4 mm or 1 padlock 6 mm TM-.../E/SVB(-SW)


3
10 M4 48 28 M4 38 4.2

Drilling dimensions

30 38

48

c21

35

Centre mounting TM-.../EZ Drilling dimensions1)

17/19

F 5.5

1.7 24.1 +0.4 0 17.9

16.2 +0.2 0

30

30

28

c20

12

23

Centre mounting with key operation TM-...+EZ/S-..


17/19 5.5 1.7 24.1 +0.4 0 17.9

Drilling dimensions1)
3.2

30

28

16.2 +0.2 0 30 c20 12 35

22.3

+0.4 0

Part no. c20 c21 TM-1... 39 42 TM-2... 51 54 TM-3... 63 66 TM-4... 75 TM-5... 87 TM-6... 99 TM-7... 111 TM-8... 123 One contact unit depth 12 mm Service distribution board mounting TM-.../IVS Part no. c1 c2 TM-1... 44 21 TM-2... 46 26.5 One contact unit depth 12 mm TM-.../IVS/S

45

60

45

60

35.5

c1

c2

35.5

42

21.5

24

Note

1))

Drilling dimensions either 16.2 mm = without reduction RMQ16; 22.3 mm = with reduction RMQ Titan

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

7/88

Dimensions Small enclosures


CI-K
Moeller HPL0211-2007/2008 Mounting rails TS-CI-K1
35

http://catalog.moeller.net

easy Relay, easy Control, easy MFD

Small insulating material enclosures CI-K1...-95-TS


17.5

4.7

7.5

39 5
1.5 12

61

45

72

127

82 120

137

4.5 80

37.5

57.5 95

39

74

CI-K2-... Part no. CI-K2-100-... CI-K2-145-... a 100 145 b 52.5 97.5


22

Mounting plates M-CI-K2


7.5 92

Mounting rails TS-CI-K2


35

5.2

7.5

52 5 57
7 65

4.7

a l

1.5

18

116

116

160

171

4.5 100 52

181

47.5 a

46

20

22

100

a 77

l 92

CI-K3-... Part no. CI-K3-125-... CI-K3-160-... a 125 160 b 74.5 109.5


24.5

Mounting plates M-CI-K3


108

Mounting rails TS-CI-K3


35

7.5

5.2

7.5

70
116

5.3

a l

5 1.5 27

65

a 93

l 108

152

200

210

222

5.5 120 70 21

50.5 a 24.5

70

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

140

Dimensions Small enclosures


http://catalog.moeller.net Moeller HPL0211-2007/2008 Mounting plates M-CI-K4 Part no. CI-K4-125-... CI-K4-160-... a 125 160 b 72.5 107.5

7/89

CI-K
easy Relay, easy Control, easy MFD
c2 84.4 84.4 84.4 Mounting rails TS-CI-K4
35

Small insulating material enclosures CI-K4-...

23

30

7.5

143.8

5.2 a

7.5

74

27 5.6 5.3 90 154 194 240 154 193 80

a 128

l 143

1.5

5 160

52.5

72.5 125

72 142

CI-K5-...
33.5

Mounting plates M-CI-K5

Mounting rails TS-CI-K5


35

50.5

183

5.2 a l

7.5

91

27 5.6

5.3 170

181

234

1.5

280

5 200

73.5 a

87 182

110

233

7.5

Typ CI-K5-125-... CI-K5-160-... Basic enclosures CI-B, CI-C, CI-D


4,5

a 125 160

b 51.5 85.5

a 168

l 183

12

c c1 c2 M4

Part no. CI-B CI-C CI-D

a 87 110 110

a1 71 95 97

b 149 165 222

b1 106 122 179

b2 128 144 201

b3 10.5 10.5 10.5

c 128 128 128

c1 115 115 115

b b2

b1

a1 a

For Moeller Electric Sales and Support call KMparts.com (866) 595-9616

b3

b2

You might also like