Conforms to IEC 255 (TV approval), UL508, CSA22.2. Slim relay with high switching power: 16 A. Dual #187 tab/PCB terminals. High impulse withstand voltage: 10 kV.
4+Ordering Information
Enclosure ratings Flux protection SPST-NO Contact form G5G-1A Standard Relays
Note: When ordering, add the rated coil voltage to the model number. Example: G5G-1A 12 VDC Rated coil voltage
G5G-(( ( VDC
1 2 3
Specifications
I
Coil Ratings
12 VDC 41.7 mA 288 W 70% max. of rated voltage 5% min. of rated voltage 110% of rated voltage Approx. 500 mW 18 VDC 27.8 mA 648 W 24 VDC 20.8 mA 1,152 W
Rated voltage Rated current Coil resistance Must operate voltage Must release voltage Max. voltage Power consumption I
Contact Ratings
16 A at 250 VAC 16 A 4,000 VA
177
G5G
I
G5G
Characteristics
100 mW max. 20 ms max. 5 ms max. 1,000 MW min. (at 500 VDC) 5,000 VAC between coil and contacts (1 min.) 1,000 VAC between contacts of same polarity (1 min.) 10,000 V (1.2 50 s) between coil and contacts Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) Malfunction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) Destruction: 1,000 m/s2 Malfunction: 150 m/s2 Mechanical: 2,000,000 operations min. (18,000 operations/hr) Electrical: 100,000 operations min. (18,000 operations/hr) Operating: -40C to 70C (with no icing) Operating: 5% to 85% Approx. 16 g
Contact resistance Operate time Release time Insulation resistance Dielectric strength Impulse withstand voltage Vibration resistance Shock resistance Endurance Ambient temperature Ambient humidity Weight I
Approved Standards
Model Coil ratings 12 VDC 18 VDC 24 VDC Contact ratings 16 A, 250 VAC Number of test operations 6,000
Reference Data
Heater Load
Load 250 VAC, 16 A (Rated Load) 220 VAC, 1.7 kW 120 VAC, 1.42 kW 121 VAC, 10.4 A 100 VAC, 12 A 100 VAC, 1.3 kW Condition 1 s ON/OFF, at room temp. 3 s ON/OFF, at 80C 3 s ON/OFF, at 80C 1.5 s ON/OFF, at 80C 1.5 s ON/OFF, at 80C 3 s ON/OFF, at 80C 100,000 380,000 500,000 580,000 200,000 290,000 Operations
Simulative Load
Load 125 VAC, Inrush current 16.5 A Steady current 5.5 A Condition 2 s ON (Inrush: 0.5 s /Steady: 1.5 s) 3 s OFF, at 45C 250,000 Operations
178
G5G
G5G
Engineering Data
Maximum Switching Power
16
Dimensions
Two, #187 tab terminals
6.350.15