Professional Documents
Culture Documents
Full Line up
www.hyundai-elec.com
|Contents
04 _ Molded Case Circuit Breaker
10 _ Miniature Series
12 _ Contactor & Overload Relay
18 _ Air Circuit Breaker
20 _ Vacuum Contactor
22 _ Vacuum Circuit Breaker
04
IEC 60947-2
Approval
NEMA AB-1
GOST-R
KS C8321
KEMA
CCC
KS
..
TSE
U-Series
ADVANCED TECHNOLOGY in size
CUSTOMIZED CHARACTERISTIC in range
POWERFUL CAPABILITY in specification
Model name
UAB type
UCB type
UPB type
UPB : Type
250 : Ampere frame size
X : Recognition code for order
Rated frequency
Utilization category
Ampere frame size
Suitability of isolation
Main characterisitics
Ui : Rated insulation voltage
Uimp : Rated impulse
withstand voltage
Ue : Rated operational voltage
Icu : R
ated ultimate
short-circuit breaking
capacity
Ics : Rated service
short-circuit breaking
capacity
Rated current
Standard
Trip unit
Trip button
05
www.hyundai-elec.com
MCCB
MINIATURE
MC
ACB
VC
VCB
50
60
100
Model
Number
of poles
AC220V
AC240V
AC380V
AC415V
AC440V
AC460V
AC600V Hydraulic
AC660V magnetic
Thermal magnetic
Fixed Adjustable
UAB30C
2, 3
3,5,10,15,20,30
10
7.5/5
2.5
UAB30R
2, 3
5,10,15,20,30
25
14/10
10
UAB50C
2, 3, 4
5,10,15,20,30,40,50
10
7.5/5
2.5
UAB50R
2, 3, 4
5,10,15,20,30,40,50
25
14/10
10
UAB50S
2, 3, 4
15,16,20,25,30,32,40,50
42
25
21
7.5
1)
UAB50H
2, 3, 4
15,16,20,25,30,32,40,50
50
30
25
10
1)
UAB60C
2, 3, 4
5,10,15,20,30,40,50,60
10
7.5/5
2.5
UAB60R
2, 3, 4
5,10,15,20,30,40,50,60
25
14/10
10
UAB100C
2, 3, 4
5,10,15,20,30,40,50,60,75,100
25
14/10
10
UAB100R
2, 3, 4
15,16,20,25,30,32,40,50,60,63,75,80,100
42
25
21
7.5
1)
UAB100S
2, 3, 4
15,16,20,25,30,32,40,50,60,63,75,80,100
50
30
25
10
1)
Dimensions (mm)
Width Height Depth
50/75
130 60
50/75/100 130 60
- The breaking capacity highlighted with blue and thick type is standard nominal value for each model in this catalogue.
1) Not applicable to 2P breaker.
Ampere
frame
Model
50
UCB50H
UCB50L
2, 3, 4 15,16,20,25,30,32,40,50
UCB50R
125
160
250
400
630
800
1000
1250
1600
Number
of poles
AC600V
AC660V
Dimensions (mm)
Width Height Depth
AC380V
AC415V
15,20,30,40,50
50
30/25
25
10
2, 3, 4 15,16,20,25,30,32,40,50
85
42
42
20
100
50
50
25
2, 3, 4
AC440V
AC460V
Thermal magnetic
Fixed Adjustable Electronic
AC220V
AC240V
UCB100R
2, 3, 4
15,16,20,25,30,32,40,50,60,63,75,80,100,125
50
30/25
25
10
UCB100S
2, 3, 4
15,16,20,25,30,32,40,50,60,63,75,80,100,125
65
42/36
35
18
UCB100H 2, 3, 4 15,16,20,25,30,32,40,50,60,63,75,80,100,125
85
42
42
20
UCB100L
100
50
50
25
UCB160H 2, 3, 4 100,125,160
85
42
42
20
UCB160L
100
50
50
25
UCB250R 2, 3, 4 125,150,160,175,200,225,250
35
25/18
18
7.5
UCB250S
2, 3, 4 125,150,160,175,200,225,250
50
35/25
25
10
UCB250N 2, 3, 4 125,150,160,175,200,225,250
65
42/36
35
18
UCB250H 2, 3, 4 125,150,160,175,200,225,250
85
42
42
20
UCB250L
100
50
50
25
UCB400R 2, 3, 4 250,300,320,350,400
35
30
25
18
UCB400S
2, 3, 4 250,300,320,350,400
50
42
35
22
UCB400H 2, 3, 4 250,300,320,350,400
85
65
50
25
UCB400L
2, 3, 4 15,16,20,25,30,32,40,50,60,63,75,80,100,125
2, 3, 4 100,125,160
2, 3, 4 125,150,160,175,200,225,250
125
100
85
30
UCB630R 2, 3, 4 500,630
50
45
35
22
UCB630S
2, 3, 4 500,630
100
65
50
25
UCB630H 2, 3, 4 500,630
100
85
65
35
UCB630L
2, 3, 4 250,300,320,350,400
2, 3, 4 500,630
125
100
85
35
UCB800R 2, 3, 4 700,800
50
45
35
25
UCB800S
2, 3, 4 700,800
100
65
50
25
UCB800H 2, 3, 4 700,800
100
85
65
35
UCB800L
125
100
85
35
2, 3, 4 700,800
60/90/120 155 60
90/90/120 155 60
60/90/120 155 60
90/90/120 155 60
105/105/140 165 60
105/105/140 164 60
105/105/140 165 60
UCB1000S
3, 4
505-1000
100
100
75
40
UCB1000L
3, 4
505-1000
150
130
100
60
UCB1250S
3, 4
630-1250
100
100
75
40
UCB1250L
3, 4
630-1250
150
130
100
60
UCB1600S
640-1600
100
65
45
25
- The breaking capacity highlighted with blue and thick type is standard nominal value for each model in this catalogue.
2P breaker has same dimension with 3P breaker, but the middle pole is removed.
210
371 151
06
125
160
250
400
630
Model
Number
of poles
AC220V
AC240V
AC380V
AC415V
AC440V
AC460V
AC660V
AC690V
Dimensions (mm)
Thermal magnetic
Fixed Adjustable Electronic
UPB100S
3, 4
15,16,20,25,30,32,40,50,60,63,75,80,100,125
100
85
65
10
UPB100H
3, 4
15,16,20,25,30,32,40,50,60,63,75,80,100,1251)
130
100
85
10
UPB100L
3, 4
15,16,20,25,30,32,40,50,60,63,75,80,100,1251)
150
130
100
25
UPB100X
3, 4
15,16,20,25,30,32,40,50,60,63,75,80,100,125
200
150
150
25
1)
1)
1)
UPB160S
3, 4
100,125,160
100
85
65
10
UPB160H
3, 4
100,125,1601)
130
100
85
10
UPB160L
3, 4
100,125,1601)
150
130
100
25
UPB160X
3, 4
100,125,1601)
200
150
150
25
UPB250S
3, 4
125,150,160,175,200,225,2501)
100
85
65
10
UPB250H
3, 4
125,150,160,175,200,225,2501)
130
100
85
10
UPB250L
3, 4
125,150,160,175,200,225,2501)
150
130
100
25
UPB250X
3, 4
125,150,160,175,200,225,2501)
200
150
150
25
UPB400S
3, 4
200-400
100
85
65
10
UPB400H
3, 4
200-400
130
100
85
10
UPB400L
3, 4
200-400
150
130
100
25
UPB400X
3, 4
200-400
200
150
150
25
UPB630S
3, 4
320-630
100
85
65
10
UPB630H
3, 4
320-630
130
100
85
10
UPB630L
3, 4
320-630
150
130
100
25
UPB630X
3, 4
320-630
200
150
150
25
- The breaking capacity highlighted with blue and thick type is standard nominal value for each model in this catalogue.
1) Rated current of electronic types are as followings; UPB100: 50-125A UPB160: 63-160A UPB250: 100-250A
Model
Number
of poles
UPB100H
UPB100L
Dimensions (mm)
AC220V
AC240V
AC380V
AC415V
2.5,3.2,6.3,12.5,20,32,50,63,80,100
130
100
85
10
2.5,3.2,6.3,12.5,20,32,50,63,80,100
150
130
100
25
UPB250H
125,150,175,200,225
130
100
85
10
UPB250L
125,150,175,200,225
150
130
100
25
AC440V
AC460V
AC660V
AC690V
Width
Height
Depth
105
165
86.5
The breaking capacity highlighted with blue and thick type is standard nominal value for each model in this catalogue.
100
225
Model
Number
of poles
Characteristics
HBL103U
15,20,30,40,50,60,75,100
200
150
100
85
25
HBL103UQ
15,20,30,40,50,60,75,100
200
150
100
85
25
HBL103UM
2.5,3.2,6.3,12.5,20,32,50,63,80,100
200
150
100
85
25
HBL103UMQ
2.5,3.2,6.3,12.5,20,32,50,63,80,100
200
150
100
85
25
HBL203U
125,150,175,200,225
200
150
100
85
25
HBL203UQ
125,150,175,200,225
200
150
100
85
25
HBL203UM
125,150,175,200,225
200
150
100
85
25
HBL203UMQ
125,150,175,200,225
200
150
100
85
25
The breaking capacity highlighted with blue and thick type is standard nominal value for each model in this catalogue.
Dimensions (mm)
Width
Height
Depth
105
165
86.5
www.hyundai-elec.com
MCCB
UCD
Ampere
frame
Model
Number Rated
of poles current (A)
Dimensions (mm)
Width
Height
Depth
90
155
60
50
UCD50H
50
100
UCD100S
100
125
UCD100H
125
160
UCD160H
160
105
165
UCD250S
250
105
164
UCD250H
250
105
165
60
400
UCD400S
400
140
257
110
630
UCD630S
630
250
800
UCD800S
800
1000
UCD1000S
1000
1250
UCD1250S
1250
MC
UAB100S
MINIATURE
Type
Ampere
frame
ACB
UCB250L
Model
Number Rated
of poles current (A)
UAD50C
UAD50S
50
100
UAD100R
100
60
125
UPD100S
125
60
160
UPD160S
160
250
UPD250S
250
400
UPD400S
400
630
UPD630S
630
210
280
110
210
370
110
UAD
UPD
50
VC
VCB
UPB400X
Dimensions (mm)
Width
Height
Depth
75
130
60
105
165
86.5
140
255
117
50
Model
Ampere
Number
Molded
case
Earth leakage of poles
frame
UMB
UMG
30
50
30
UDB
UDG
50
100
ated residual
current [In]
(mA) for ELCB
AC440V
AC460V
Width
Height
Depth
33
70
57
35
80
60
50/75
96
60
75/75
96
60
UMG30R
15,20,30
15, 30
2.5
UMB30S
UMG30S
15,20,30
15, 30
UMB30H
UMG30H
15,20,30
15, 30
10
UMB50S
UMG50S
15,20,30,40,50
15, 30
UMB50H
UMG50H
15,20,30,40,50
15, 30
10
UDB30S
UDG30S
2, 3
3,5,10,15,20,30
15, 30
2.5
2.5
UDB30H
UDG30H
2, 3
2.5
2.5
UDB50S
UDG50S
2, 3
UDB50H
UDG50H
2, 3
5,10
15,20,30
5,10,15,20,30,40,50
5,10
15,20,30,40,50
15, 30
15, 30
15, 30
Dimensions (mm)
AC380V
AC415V
UMB30R
10
2.5
2.5
2.5
2.5
10
UDB100S UDG100S
2, 3
15,20,30,40,50,60,75,100
30, 100
2.5
2.5
UDB100H UDG100H
2, 3
15,20,30,40,50,60,75,100
30, 100
10
- KS certified products. English nameplate and 50Hz marking are not available.
- The breaking capacity highlighted with blue and thick type is standard nominal value for each model in this catalogue.
2P breaker has same dimension with 3P breaker, but the middle pole is removed.
07
08
Accessories
The applicable accessories of each MCCB are not same as above. For exact application to each MCCB, please reter to product catalogue.
www.hyundai-elec.com
MCCB
MINIATURE
MC
ACB
VC
Hi-Series
Fixed thermal type
Frame
30
50
60
100
225
400
600
800
Model
HiBS30
HiBH30
HiBE50
HiBS50
HiBH50
HiBE60
HiBS60
HiBE100
HiBS100
HiBH100
HiBE225
HiBS225
HiBH225
HiBE400
HiBS400
HiBH400
HiBL400
HiBE600
HiBS600
HiBH600
HiBL600
HiBE800
HiBS800
HiBH800
HiBL800
Number of
poles
2, 3
2, 3
2, 3, 4
2, 3, 4
2, 3, 4
2, 3, 4
2, 3, 4
2, 3, 4
2, 3, 4
2, 3, 4
21), 3, 4
21), 3, 4
21), 3, 4
21), 3, 4
21), 3, 4
21), 3, 4
21), 3, 4
21), 3, 4
21), 3, 4
21), 3, 4
21), 3, 4
21), 3, 4
21), 3, 4
21), 3, 4
21), 3, 4
380/415V
7.5/5
14/10
7.5/5
14/10
30/25
7.5/5
14/10
14/10
30/25
42/36
25/18
35/25
42/36
30
42
65
100
45
65
85
100
45
65
85
100
600V
2.5
5
2.5
5
10
2.5
5
5
10
18
7.5
10
18
18
22
25
30
22
25
35
35
25
25
35
35
HiBS103
100
225
250
Model
HiBL50NT
HiBX50NT
HiBS100J
HiBH100J
HiBL100NT
HiBX100NT
HiBL225NT
HiBX225NT
HiBE250J
HiBS250J
HiBH250J
Number of
poles
3, 4
3, 4
2, 3, 4
3, 4
3, 4
3, 4
3, 4
21), 3, 4
380/415V
85
130
30/25
42/36
85
130
85
130
25/18
35/25
42/36
600V
35
65
10
18
35
65
35
65
7.5
10
18
HiBL203NE
Electronic type
Frame
Model
Number of
poles
50
100
225
HiBL50NE
HiBL100NE
HiBL225NE
HiBS400NE
HiBL400NE
HiBX400NE
HiBS600NE
HiBL600NE
HiBX600NE
HiBS800NE
HiBL800NE
HiBX800NE
HiBS1000NE
HiBL1000NE
HiBS1200NE
HiBL1200NE
3, 4
3, 4
3, 4
3, 4
3, 4
3, 4
3, 4
3, 4
3, 4
3, 4
3, 4
3, 4
3, 4
3, 4
3, 4
3, 4
400
600
800
1000
1200
1) 2 pole has same dimension with 3 pole, but middle pole is removed.
2) 250A for HiBL225NT and HiBL225NE is non-standard and available on special request.
3) 630A for HiBS600NE, HiBL600NE and HiBX600NE is non-standard and available on special request.
380/415V
85
85
85
50
85
130
65
85
130
65
85
130
100
130
100
130
600V
35
35
35
30
35
65
35
42
65
35
42
65
50
65
50
65
HiBS803NE
09
VCB
10
Miniature Series
Miniature Circuit Breaker [ MCB ]
Miniature Switch Disconnector [ MSD ]
HYUNDAI Miniature Series are the perfect solution to protect electric overload, short circuit
and earth leakage in the household and commercial installations.
With consistent and elegant appearances, the Hyundai Miniature Series provide various selection, easy
installation, economic benefit and high reliability based on international standard IEC.
Qualified Standard & Approval
Standard
IEC 60898
IEC 61009
IEC 60947-2
IEC 60947-3
IEC 61008
Approval
GOST-R
KEMA
TSE
HiBD63-N
HiRC63-N
HiRO40
HBD51h
HiBD125
HiBD63h
HiBD63-N
HiBD63-NS
HiBD63-S
HiBD63-E
IEC/EN60947-2
IEC/EN60898
IEC/EN60898
IEC/EN60898
IEC/EN60898
IEC/EN60898
1, 2, 3, 4,
1+N, 3+N
1, 2, 3, 4,
1+N, 3+N
1, 2, 3, 4,
1+N, 3+N
1+N
(1 pole size)
1, 2, 3, 4
1, 2, 3, 4
1, 2, 3, 4, 5, 6,
10, 13, 15, 16, 20,
25, 32, 40, 50, 63
1, 2, 3, 4, 5, 6,
10, 13, 15, 16, 20,
25, 32, 40, 50, 63
1, 2, 3, 4, 6,
10, 13, 16,
20, 25, 32, 40
1, 2, 3, 4, 5, 6,
10, 13, 15, 16,
20, 25, 32, 40
1, 2, 3, 4, 5, 6,
10, 13, 15, 16,
20, 25, 32, 40
Model
Standard
AC500
AC500
AC500
AC500
AC500
AC500
AC240/4151)
AC240/4151)
AC240/4151)
AC240
AC240/4151)
AC240/4151)
4.5
10
10
6(1-25A),
4.5(32-40A)
AC220/240V
10
10
6(1-25A),
4.5(32-40A)
4.5
Rated
IEC60898 AC380V
short-circuit
breaking
AC400/460V
capacity [Icu]
AC220/240V
(kA r.m.s.)
IEC60947-2
AC400/460V
10
10
6(1-25A),
4.5(32-40A)
4.5
10
10
6(1-25A),
4.5(32-40A)
4.5
3
6
Accessories
15
15
10
10
7.5
15
15
10
10
7.5
75
75
100
100
100
100
B, C, D
B, C, D
B, C, D
B, C
B, C
B, C
Electrical
10,000
10,000
10,000
10,000
10,000
10,000
Mechanical
20,000
20,000
20,000
20,000
20,000
20,000
120
120
120
120
120
120
Auxiliary switch
Shunt trip
11
www.hyundai-elec.com
MINIATURE
MCCB
MC
ACB
VC
VCB
HiSD125
IEC/EN60947-3
1, 2, 3, 4
16, 32, 63, 100, 125
AC500
AC240/4151)
4
10,000
20,000
120
HiRC100-N
HiRC63-N
HiRC63
HiRO40
HiRD125
HiRD63
HiRD32
120
120
120
120
Mini Breaker
Model
Standard
Number of poles (P)
Rated current (A)
Rated insulation voltage [Ui] (V)
Rated operational voltage [Ue] (V)
Rated impulse withstand voltage [Uimp] (kV)
Rated
Ultimate [Icu] AC220/240V, 50-60Hz
short-circuit (kA r.m.s.)
DC125V
breaking
capacity
Service [Ics] % of [Icu]
Terminal connection
Model
Standard
Number of poles (P)
Rated current (A)
Rated insulation voltage [Ui] (V)
Rated operational voltage [Ue] (V)
Rated impulse withstand voltage [Uimp] (kV)
Rated
Ultimate [Icu] AC220/240V, 50-60Hz
short-circuit (kA r.m.s.)
DC125V
breaking
capacity
Service [Ics] % of [Icu]
Terminal connection
1) AC460V is not applicable for 1P breaker.
HBD51D HBD52D HBD53D HBD51HD HBD52HD HBD53HD HBD101HD HBD102HD HBD103HD HBD101HDC HBD102HDC HBD103HDC
IEC60947-2
1
2
3
10, 15, 20, 30, 40, 50
AC460
AC240/4601)
6
5
5
50
Screw
HBD51
HBD52
HBD53
IEC60947-2
1
2
3
10, 15, 20, 30, 40, 50
AC460
AC240/4601)
6
5
5
50
Screw
IEC60947-2
1
2
3
10, 15, 20, 30, 40, 50
AC460
AC240/4601)
6
10
10
50
Screw
IEC60947-2
IEC60947-2
1
2
3
1
2
3
10,15,20,30,40,50,60,70,80,90,100 10,15,20,30,40,50,60,70,80,90,100
AC460
AC460
AC240/4601)
AC240/4601)
6
6
10
10
10
10
50
50
Screw
Cage lug
IEC60947-2
1
2
3
10, 15, 20, 30, 40, 50
AC460
AC240/4601)
6
10
10
50
Screw
IEC60947-2
IEC60947-2
1
2
3
1
2
3
10,15,20,30,40,50,60,70,80,90,100 10,15,20,30,40,50,60,70,80,90,100
AC460
AC460
AC240/4601)
AC240/4601)
6
6
10
10
10
10
50
50
Screw
Cage lug
12
Approval
IEC 60947
EN 60947
UL 508
KERI
KS
VDE 0660
UL / C-UL
DNV
TSE
KS C4504
GOST-R
CCC
..
U-Series
UMC9
UMC225
Magnetic Contactor
Model
UMC9
Durability
Auxiliary
contact
(standard)
Dimensions
(WxHxD, mm)
1NO or 1NC
44x75x80(AC)
44x75x112(DC)
AC,DC
45x83x94(AC)
45x83x127(DC)
AC,DC
2NO+1NC
(DC only)
55x106x111
AC,DC
2NO+1NC
(DC only)
70x140x128
AC/DC
2NO+2NC
103x155x146
AC/DC
2NO+2NC
138x204x174
AC/DC
2NO+2NC
163x243x203
AC/DC
2NO+2NC
276x314x253
Operation
Mechanical current
25,000
AC,DC
25,000
AC1000V
-
Electrical
2,500
7.5/9
2,500
UMC12
3.5/12
5.5/12
7.5/12
UMC18
4.5/18
7.5/18
8.5/15
7.5/9
2,500
15,000
UMC25
5.5/25
11/25
15/22
15/18
2,500
15,000
UMC32
7.5/32
15/32
18.5/28
18.5/22
2,000
15,000
UMC40
11/40
18.5/40
22/32
22/23
2,000
15,000
UMC50
15/50
22/50
30/43
30/28
2,000
15,000
UMC65
18.5/65
30/65
33/60
33/35
2,000
15,000
UMC75
22/75
37/75
37/64
37/42
2,000
10,000
UMC85
25/85
45/85
50/75
45/45
2,000
10,000
UMC100
30/100
55/100
50/85
45/65
2,000
10,000
UMC115
37/115
60/115
59/100
55/65
65/50
1,000
5,000
UMC130
40/130
65/130
70/120
75/82
75/54
1,000
5,000
UMC150
45/150
75/150
90/140
90/120
90/66
1,000
5,000
UMC185
55/185
90/185
110/180
110/120
110/78
1,000
5,000
UMC225
75/225
132/225
132/200
132/150
132/96
1,000
5,000
UMC265
80/265
147/265
150/225
160/173
160/113
1,000
5,000
UMC300
90/300
160/300
200/273
200/220
200/141
1,000
5,000
UMC400
125/400
220/400
250/300
250/300
250/178
1,000
5,000
UMC500
140/500
250/500
300/426
335/360
275/192
50
500
UMC630
190/630
330/500
330/500
400/412
300/213
50
500
UMC800
220/800
440/800
500/720
500/630
400/284
50
500
www.hyundai-elec.com
MCCB
MC
MINIATURE
ACB
VC
VCB
Rated
current
(A)
Auxiliary contact
(standard)
Dimensions
(WxHxD, mm)
UTH12
UTH32
0.12-0.15-0.18
0.18-0.22-0.26
0.12-0.15-0.18 0.25-0.3-0.35
0.18-0.22-0.26 0.34-0.42-0.5
0.25-0.3-0.35
0.5-0.6-0.7
0.34-0.42-0.5
0.6-0.75-0.9
0.5-0.6-0.7
0.8-1-1.2
0.6-0.75-0.9
1.1-1.35-1.6
0.8-1-1.2
1.5-1.8-2.1
1.1-1.35-1.6
2-2.5-3
1.5-1.8-2.1
2.8-3.5-4.2
2-2.5-3
3-4-5
2.8-3.5-4.2
4-5-6
3-4-5
5.6-6.8-8
4-5-6
6-7.5-9
5.6-6.8-8
8-10-12
6-7.5-9
12-15-18
8-10-12
15-18.5-22
17-21-25
22-27-32
UTH65
UTH100
7-8.5-10
8-10-12
12-15-18
15-18.5-22
17-21-25
22-27-32
28-34-40
34-42-50
45-55-65
13
UTH150
UTH265
UTH400
UTH800
17-21-25
22-27-32
28-34-40
34-42-50
45-55-65
52-63-75
59-72-85
70-85-100
48-64-80
69-92-115
78-104-130
90-120-150
48-64-80
69-92-115
78-104-130
90-120-150
111-148-185
135-180-225
159-212-265
90-120-150
111-148-185
135-180-225
159-212-265
180-240-300
240-320-400
300-400-500
378-504-630
480-640-800
1NO+1NC
1NO+1NC
1NO+1NC
1NO+1NC
1NO+1NC
1NO+1NC
1NO+1NC
1NO+1NC
45x79x76
45x81x91
55x94x105
70x108x123
180x159x187
180x185x185
180x205x185
245x223x197
UMC9
Applied
contactor
UMC18
UMC25
UMC32
UMC40
UMC50
UMC65
UMC75
UMC85
UMC100
UMC115
UMC130
UMC150
UMC185
UMC225
UMC265
UMC300
UMC12
UMC400
UMC500
UMC630
UMC800
Separate mounting
block (option)
UTHMB12
UTHMB32
UTHMB65
UTHMB100
14
Auxiliary contact
UMX04
0NO+4NC
UMX13
1NO+3NC
UMX22
2NO+2NC
UMX31
UMX40
Operation current
Model
Auxiliary contact
UMT04
0NO+4NC
UMT13
1NO+3NC
UMT22
2NO+2NC
3NO+1NC
UMT31
3NO+1NC
4NO+0NC
UMT40
4NO+0NC
AC
Operation current
DC
Auxiliary contact
UAB02
0NO+2NC
UAB11
1NO+1NC
UAB20
2NO+0NC
UAB04
0NO+4NC
UAB13
1NO+3NC
UAB22
2NO+2NC
UAB31
3NO+1NC
UAB40
4NO+0NC
UAL65
1NO+1NC
UMC9-65
UAL100
1NO+1NC
UMC75-100
UAL400
1NO+1NC
UMC115-800
UMC9-100
UMX, UMT
Mounting position
Applicable product
Front
Side
Applied contactors
Model
Control voltage
Applicable product
UTL65 S
UMC9-65
UTL100
UMC75-100
UET1
UET2
AC/DC90-240V
AC/DC24-60V
UMC9-100,
UMX, UMT
UTL265
UMC115-265
UTL400
UMC300-800
Surge Absorber
Control voltage
Applicable product
Item
Model
AC/DC24
AC/DC48
ULB100
AC/DC100-125
AC/DC200-240
Control voltage
AC24-48V
UMC9-100,
UMX, UMT
URC32
AC240-380V
RC-unit
AC440
AC110-220V
Applicable product
UMC9-32,
UMX
AC24-48V
URC100
AC110-220V
UMC40-100
AC240-380V
Clamping diode
UCD100
DC24-125V
UMT
www.hyundai-elec.com
MCCB
MINIATURE
MC
ACB
VC
Accessories
1. Contactor UMC
2. Front safety cover
3. Auxiliary contact block (Front mounting) UAB
4. Auxiliary contact block (Side mounting) UAL
5. Mechanical latching block ULB
6. Electronic timer block UET
7. Mechanical interlock unit UTL
8. Surge absorber URC/UCD
9. Thermal overload relay UTH
4
1
7
4
2
3
The applicable accessories of each contactor are not same as above. For exact application to each contactor, please refer to product catalogue.
Applicable product
UMC100IC
UMC150IC
UMC115-150
UMC265IC
UMC185-265
UMC400IC
UMC300-500
UMC800IC
UMC630-800
Feature
Moving contacts
Item
Model
Main contact
UMCTIP
Terminal
protection
cover
UMC_PC
Spare Part
Feature
Item
Model
Coil
UMCOL
Fixed contacts
Main
terminal cover
Arc chute
UMCHT
Coil
terminal cover
Auxiliary contact
terminal cover
15
VCB
16
Magnetic Contactor
HiMC130
Model
HiMC9
HiMC12
HiMC18
HiMC22
HiMC32
HiMC40
HiMC50
HiMC65
HiMC80
HiMC90
HiMC110, HiMC110B 2)
HiMC130
HiMC150, HiMC150B 2)
HiMC180
HiMC220
HiMC260, HiMC260B 2)
HiMC300
HiMC400
HiMC500
HiMC630
HiMC800
200-240V
380-440V
500-550V
660-690V
1,000V
2.2/10
3.7/13
4.5/18
5.5/22
7.5/32
11/40
15/50
18.5/70
22/80
25/90
30/110
37/130
45/150
55/180
63/220
75/260
90/300
125/400
140/500
190/630
220/800
4/9
5.5/12
7.5/18
11/22
15/32
18.5/40
22/50
30/65
37/80
45/90
55/110
65/130
75/150
90/180
110/220
132/260
160/300
220/400
250/500
330/630
440/800
4/7
7.5/12
8.5/15
15/22
18.5/28
22/32
30/45
37/60
45/64
50/80
60/110
70/120
90/140
110/180
132/200
150/220
160/273
220/350
300/426
330/500
500/720
5.5/7
7.5/9
7.5/9
15/18
18.5/22
22/26
25/31
37/44
45/52
50/60
55/65
60/70
90/100
110/120
132/150
160/173
200/220
250/300
335/360
400/412
500/630
65/50
75/54
90/66
110/78
132/96
160/113
200/141
250/178
275/192
300/213
400/284
Auxiliary contact
Operation current
1NO+1NC
1NO+1NC
1NO+1NC
1NO+1NC
2NO+2NC
2NO+2NC
2NO+2NC1)
2NO+2NC1)
2NO+2NC1)
2NO+2NC1)
2NO+2NC1)
2NO+2NC1)
2NO+2NC1)
2NO+2NC1)
2NO+2NC1)
2NO+2NC1)
2NO+2NC1)
2NO+2NC1)
2NO+2NC1)
2NO+2NC1)
2NO+2NC1)
AC, DC
AC, DC
AC, DC
AC, DC
AC, DC
AC, DC
AC, DC
AC, DC, AC/DC
AC, DC, AC/DC
AC, DC, AC/DC
AC, DC, AC/DC
AC, DC, AC/DC
AC, DC, AC/DC
AC, DC, AC/DC
AC, DC, AC/DC
AC, DC, AC/DC
AC, DC, AC/DC
AC, DC, AC/DC
AC, DC, AC/DC
AC, DC, AC/DC
AC, DC, AC/DC
HiMK
HiMK9 21
HiMK9 12
HiMK12 21
HiMK12 12
HiMK18 21
HiMK18 12
HiMK22 21
HiMK22 12
HiMK32 32
HiMK32 23
HiMK40 32
HiMK40 23
HiMK50 32
HiMK50 23
Composed devices
Max. power
Contactor
AC-6b
200V
kVAR
230V
240V
kVAR
400V
415V
kVAR
6.7
6.7
440V
kVAR
500V
550V
kVAR
690V
kVAR
9.7
9.7
14
14
HiMC9
12.5
12.5
18
18
HiMC12
(AC operation)
8.5
16.7
16.7
24
24
HiMC18
10
10
18
18
26
26
HiMC22
16
27.5
External size
Auxiliary
8.5
14
Dimension
30
34
45
HiMC32
20
20
30
33.3
48
48
HiMC40
21
24
40
45
50
65
HiMC50
Model
HiAD50 10
HiAD50 01
HiAD50 10
HiAD50 01
HiAD50 10
HiAD50 01
HiAD50 10
HiAD50 01
HiAD50 10
HiAD50 01
HiAD50 10
HiAD50 01
HiAD50 10
HiAD50 01
NO
NC
(53-54) (51-52)
WxHxD
(mm)
1
1
1
1
1
44x166x123
1
1
1
1
1
1
63x166x123
1
1
1
70x178x136
17
www.hyundai-elec.com
MCCB
HiTH22
MC
MINIATURE
ACB
HiTH90
VC
VCB
HiTH130
HiTH22
HiTH40
HiTH50
HiTH90
HiTH130
HiTH220
HiTH300
HiTH500
HiTH800
0.12-0.18
0.18-0.26
0.25-0.35
0.34-0.5
0.5-0.7
0.6-0.9
0.8-1.2
1.1-1.6
1.5-2.1
2-3
2.8-4.2
3-5
4-6
7-10
9-13
12-18
16-22
7-10
9-13
12-18
16-22
18-26
24-32
28-40
18-26
24-32
28-40
36-50
28-40
36-50
45-65
60-80
70-90
48-80
78-130
78-130
108-180
132-220
132-220
180-300
180-300
240-400
300-500
378-630
480-800
Applied
contactor
HiMC9
HiMC12
HiMC18
HiMC22
HiMC32
HiMC40
HiMC50
HiMC65
HiMC80
HiMC90
HiMC110B
HiMC110
HiMC130
HiMC150B
HiMC150
HiMC180
HiMC220
HiMC260B
HiMC260
HiMC300
HiMC400
HiMC500
HiMC630
HiMC800
Separate mounting
block (option)
ITHMB22
ITHMB40
ITHMB50
ITHMB90
Rated
current
(A)
Deluxe type
Standard type
Standard Type
Over
current
Phase
failure
Phase
Restriction
unbalance
Reverse
phase
HiMP22K I
HiMP40K I
HiMP50K I
Inverse
HiMP150K I
HiMP300K I
Inverse
HiMP22K N
HiMP40K N
HiMP50K N
Inverse/
Reverse
HiMP150K N
HiMP300K N
Inverse/
Reverse
Pin
Screw
Tunnel
HiMP150: 30-150A
HiMP300: 60-300A
HiMP150: 30-150A
HiMP300: 60-300A
Deluxe Type
Function
Model
HiMP60K S
HiMP60K I
HiMP60K Z
Over
current
Under
curren
Phase
failure
Phase
Restriction
unbalance
Reverse
phase
Short
circuit
Leakage
current
Screw
Tunnel
Allowable current
partition
0.5-6A, 5-60A
18
Approval
IEC 60947-2
EN 60947-2
AS 3972-2
KERI
KS
ANSI C37.13
GOST-R
VDE 0660
CCC
GOST-R 50030.2-99 9
..
GOST-R 50030.1-2000
UAN Type
UAN Type
Model
Rated current (A)
UAN06
UAN08
UAN10
UAN12
UAN16
UAN20
UAN32
UAN40
UAN50
630
800
1,000
1,250
1,600
2,000
3,200
4,000
5,000
Number of pole
3, 4
Utilization category
AC1,000
AC690
Rated breaking
capacity (kA sym) [Icu]
with Inst.
Icu=100% Ics
Rated making
capacity (kA peak) [Icm]
with Inst.
Icu=100% Ics
AC690V
65
65
65
65
65
65
85
85
85
AC500V
85
85
85
85
85
85
100
100
100
AC415V below
85
85
85
85
85
85
100
100
100
AC690V
143
143
143
143
143
143
187
187
187
AC500V
187
187
187
187
187
187
220
220
220
AC415V below
187
187
187
187
187
187
220
220
220
1 sec
12
65
65
65
65
65
65
85
85
85
65
65
65
65
65
65
85
85
85
0.05
Closing
Charging time (sec) max.
operating
Closing time (sec) max.
time
Dimensions (mm)
(3pole, Draw-out type)
10
0.04
Height
460
Width
328
Depth
405
460
399
656
439.2
www.hyundai-elec.com
MCCB
MINIATURE
MC
ACB
VC
VCB
HiAN06
HiAN08
HiAN10
HiAN12
HiAN16
HiAN20
HiAN25
HiAN32
HiAN40
HiAN50
HiAN63
630
800
1,000
1,250
1,600
2,500
3,200
4,000
5,000
6,300
50
70
70
105
154
154
50
70
70
105
154
154
50
70
70
105
154
154
50
70
70
105
154
154
50
70
70
105
154
154
2,000
3, 4
B
AC1,000
AC690
65
70
85
143
154
187
8
65
85
85
143
187
187
65
85
85
143
187
187
85
100
100
187
220
220
100
120
120
220
291
291
100
120
120
220
291
291
65
65
65
65
65
70
85
85
75
100
100
65
65
65
65
65
70
0.04
10
85
85
75
100
100
43
65
51
76
43
65
51
76
43
65
51
76
49
72
58
85
49
72
58
85
60
87
69
100
63
92
76
110
65
96
83
120
1 sec
0.04
0.06
115
210
230
135
230
478
250
490
320
410
480
984
461.2
481
HiAS Type
Model
HiAS06
HiAS08
HiAS10
HiAS12
630
800
1,000
1,250
42
50
50
88.2
110
110
42
50
50
88.2
110
110
42
50
50
88.2
110
110
42
42
42
42
42
42
42
42
1 sec
HiAS16
HiAS20
HiAS25
HiAS32
2,000
2,500
3,200
50
65
65
105
143
143
50
65
65
105
143
143
50
65
65
105
143
143
42
50
50
50
42
50
50
50
49
72
58
85
60
87
69
100
63
92
76
110
65
96
83
120
1,600
3, 4
B
AC1,000
AC690
42
42
50
50
50
50
88.2
88.2
110
110
110
110
8
0.04
10
0.04
43
65
51
76
43
65
51
76
43
65
51
76
49
72
58
85
459
320
410
461.2
19
20
Vacuum Contactor
HYUNDAI Vacuum Contactors are designed and manufactured for frequent
switchings, especially taking into account safety and quality assurance.
They are suitable for switching and controlling squirrel cage and
slipring motors, medium voltage loads and resistance furnaces,
and capacitors and transformers.
Qualified Standard & Approval
Standard
IEC 60470
Approval
UL 347
KERI
NEMA ICS 3
UL, c-UL
UVC Type
Fixed type
Structure
Ratings
Draw-out type
Operating
Continuously energized
32C
34C
62C
64C
32C
34C
62C
64C
method
Latched
32L
34L
62L
64L
32L
34L
62L
64L
3.6
7.2
3.6
7.2
3.3
6.6
3.3
6.6
50/60
200
400
200
400
Impulse (kV)
60
20
lifetime
1 sec
6.3
30 sec
Continuously energized
1,000
(1,000 times)
250
300
AC/DC100-125, AC/DC200-230
Auxiliary contact
Motor (kW)
load capacity
400
Applicable
200
AC3
Breaking capacity
Mechanical
400
Utilization category
Short-time
current
[kA]
200
3a2b
750
1,500
1,500
3,000
750
1,500
1,500
3,000
Transformer (kVA)
1,000
2,000
2,000
4,000
1,000
2,000
2,000
4,000
Condensor (kVAR)
750
1,200
1,500
2,000
750
1,200
1,500
2,000
X1 19
B1 B2 33
B1 B2 35
A1 28
D1 D2 35
D1 D2 38
www.hyundai-elec.com
MCCB
MINIATURE
MC
VC
ACB
VCB
HCA Type
Structure
Ratings
Fixed type
Draw-out type
Operating
Continuously energized
32C
34C
62C
64C
82C
84C
32C
34C
62C
64C
82C
84C
method
Latched
32L
34L
62L
64L
82L
84L
32L
34L
62L
64L
82L
84L
3.6
7.2
12
3.6
7.2
12
3.3
6.6
11
3.3
6.6
11
50/60
200
400
200
400
400
200
400
45
60
75
16
20
28
16
20
28
AC3
AC4
AC3
AC4
4kA (O-3min-CO-3min-CO)
1 sec
6.3
6.3
6.3
6.3
6.3
6.3
30 sec
2.4
2.4
2.4
2.4
2.4
2.4
1,000
1,000
1,000
1,000
1,000
1,000
250
250
250
250
250
250
2a2b2)
5a5b
Continuously energized
(1,000 times)
300
AC110/125/220, DC110/125/220
Auxiliary contact
Motor (kW)
load capacity
200
75
Applicable
400
60
Breaking capacity
lifetime
200
45
Utilization category
Mechanical
400
Impulse (kV)
Short-time
current
[kA]
200
2a2b
2a2b
2)
750
1,500
1,500
3,000
3,000
6,000
750
1,500
1,500
3,000
3,000
6,000
Transformer (kVA)
1,000
2,000
2,000
4,000
4,000
8,000
1,000
2,000
2,000
4,000
4,000
8,000
Condensor (kVAR)
750
1,200
1,500
2,000
3,000
4,000
750
1,200
1,500
2,000
3,000
4,000
F 21
F 22
F 61
B 38
A 30
A 32
A 68
D 403)
D 433)
J 33
J 35
H 43
H 46
3)
3)
B 41
3)
B 804)
D 834)
3)
21
22
Approval
ESB 150
KEMA
ANSI C37.09
KERI
KSC 4611
KR, GL
GOST-R 52565-06
HVF type
HVG type
IEC 62271-100
Withstand voltage
Type
Rated
(kV)
voltage (kV) Power-frequency/
Impulse
7.2
20/60
28/75
12
42/75
HVF
17.5
HVG
38 / 95
Rated
breaking
current(kA)
Model1)
630
1,250
2,000
2,500
3,150
4,000
25
HVF114
31.5
HVF115
40
HVF116
50
HVF117
25
HVF214
31.5
HVF215
40
HVF216
50
HVF217
25
HVF224
2)
31.5
2)
HVF225
40
HVF2262)
25
HVF314
31.5
HVF315
40
HVF316
24/25.8
50/125
(65/125) 2)
12.5
HVF611
25
HVF614
24
65/125
25
HVF6252)
36
70/170
25
HVF714
31.5
HVF705
36/40.5
95/190
31.5
HVF725
HVG109
12.5
HVG101
20
HVG113
25
HVG114
7.2
20/60
2)
2)
2)
1) Model number in the square "" shall be listed as below for the rated current according to applied standard.
- IEC standard: 1 630A 2 1,250A 4 2,000A 6 2,500A 7 3,150A 8 4,000A 9 400A
2) HVF224 , 225 , 226 , 611 , 614 , 625 , 725 are applicable to GOST-R standard.
www.hyundai-elec.com
MCCB
MC
MINIATURE
15kV
ACB
VCB
VC
38kV
ANSI C37.09
Withstand voltage
Type
Rated
(kV)
voltage (kV) Power-frequency/
Impulse
Rated
breaking
current(kA)
19/60
HVF
2,000
HVF154
HVF144
40
HVF146
50
HVF147
HVF354
HVF344
HVF346
HVF336
31.5
HVF705
40
HVF706
25
15
36/95
40
38
80/150
25
4.76
Model1)
1) Model number in the square "" shall be listed as below for the rated current according to applied standard.
- ANSI standard: 2 1,200A 4 2,000A 6 2,500A 7 3,000A 8 4,000A
2,500
3,000
23
4,000
www.hyundai-elec.com
Head Office
Seoul
(Sales & Marketing)
Atlanta
New Jersey
London
Tokyo
8th Fl., Yurakucho Denki Bldg.1-7-1, Yuraku-Cho, Chiyoda-Ku, Tokyo, 100-0006, Japan
Tel: 81-3-3212-2076, 3215-7159
Fax: 81-3-3211-2093
Osaka
I-Room 5th Fl. Nagahori-Plaza Bldg. 2-4-8, Minami Senba, Chuo-Ku, Osaka, 542-0081, Japan
Tel: 81-6-6261-5766, 5767
Fax: 81-6-6261-5818
Riyadh
2nd Floor, The Plaza, P.O Box 21840, Riyadh 11485, Saudi Arabia
Tel: 966-1-462-2331
Fax: 966-1-464-4696
Dubai
205, Building 4, Emaar Square, Sheikh Zayed Road, Pobox 252458, Dubai, UAE
Tel: 971-4-425-7995
Fax: 971-4-425-7996
Kuwait
Moscow
World Trade Center, Ent. 3, #1902, Krasnopresnenskaya Nab. 12, Moscow, 123610, Russia
Tel: 7-495-258-1381
Fax: 7-495-258-1382
Madrid
Sofia
Montgomery
Yangzhong
No.9 Xiandai Road, Xinba Scientific and Technologic Zone, Yangzhong, Jiangsu, P.R.C. Zip: 212212, China
Tel: 86-511-8842-0666, 0212
Fax: 86-511-8842-0668, 0231
Fax: 82-2-746-7441
Fax: 359-2-803-3203