You are on page 1of 24

LV & MV Circuit Breaker, Contactor & Overload Relay

LV & MV Circuit Breaker

Full Line up

www.hyundai-elec.com

LV & MV Circuit Breaker,


Contactor & Overload Relay
HYUNDAI Circuit Breaker is one of the most reliable and
sophisticated products, which realizes the optimum design
through electric and kinetic analysis.

|Contents
04 _ Molded Case Circuit Breaker
10 _ Miniature Series
12 _ Contactor & Overload Relay
18 _ Air Circuit Breaker
20 _ Vacuum Contactor
22 _ Vacuum Circuit Breaker

04

HYUNDAI HEAVY INDUSTRIES

LV & MV Circuit Breaker, Contactor & Overload Relay

Molded Case Circuit Breaker


Optimum design provides easy-to-use customer installation, while offering versatility and high performance to
match today's demand for a reliable and cost-effective product, which is easy to maintain.

Qualified Standard & Approval


Standard

IEC 60947-2

Approval

ISO 18001, 14001, 9001

NEMA AB-1

CE (Community European / TUV Rheinland)

GOST-R

KS C8321

KEMA

CCC

KS

KR, ABS, BV, NK, RINA, LR, GL

..

TSE

U-Series
ADVANCED TECHNOLOGY in size
CUSTOMIZED CHARACTERISTIC in range
POWERFUL CAPABILITY in specification

Model name

UAB type
UCB type
UPB type

Line side terminal

UPB : Type
250 : Ampere frame size
X : Recognition code for order

Rated frequency

Utilization category
Ampere frame size
Suitability of isolation

Main characterisitics
Ui : Rated insulation voltage
Uimp : Rated impulse
withstand voltage
Ue : Rated operational voltage
Icu : R
 ated ultimate
short-circuit breaking
capacity
Ics : Rated service
short-circuit breaking
capacity

Rated current
Standard

Trip unit

Trip button

Approvals and certificates

Load side terminal

05

www.hyundai-elec.com

MCCB

MINIATURE

MC

ACB

VC

VCB

UAB type / 30-100AF


Ampere
frame
30

50

60

100

Model

Breaking capacity [Icu] (kA r.m.s.)

Number
of poles

Rated current (A)

AC220V
AC240V

AC380V
AC415V

AC440V
AC460V

Trip mechanism & Characteristics

AC600V Hydraulic
AC660V magnetic

Thermal magnetic
Fixed Adjustable

UAB30C

2, 3

3,5,10,15,20,30

10

7.5/5

2.5

UAB30R

2, 3

5,10,15,20,30

25

14/10

10

UAB50C

2, 3, 4

5,10,15,20,30,40,50

10

7.5/5

2.5

UAB50R

2, 3, 4

5,10,15,20,30,40,50

25

14/10

10

UAB50S

2, 3, 4

15,16,20,25,30,32,40,50

42

25

21

7.5

1)

UAB50H

2, 3, 4

15,16,20,25,30,32,40,50

50

30

25

10

1)

UAB60C

2, 3, 4

5,10,15,20,30,40,50,60

10

7.5/5

2.5

UAB60R

2, 3, 4

5,10,15,20,30,40,50,60

25

14/10

10

UAB100C

2, 3, 4

5,10,15,20,30,40,50,60,75,100

25

14/10

10

UAB100R

2, 3, 4

15,16,20,25,30,32,40,50,60,63,75,80,100

42

25

21

7.5

1)

UAB100S

2, 3, 4

15,16,20,25,30,32,40,50,60,63,75,80,100

50

30

25

10

1)

Dimensions (mm)
Width Height Depth

50/75

130 60

50/75/100 130 60

- The breaking capacity highlighted with blue and thick type is standard nominal value for each model in this catalogue.
1) Not applicable to 2P breaker.

UCB type / 50-1600AF


Breaking capacity [Icu] (kA r.m.s.)

Ampere
frame

Model

50

UCB50H
UCB50L

2, 3, 4 15,16,20,25,30,32,40,50

UCB50R

125

160

250

400

630

800

1000
1250
1600

Number
of poles

Rated current (A)

AC600V
AC660V

Trip mechanism & Characteristics

Dimensions (mm)
Width Height Depth

AC380V
AC415V

15,20,30,40,50

50

30/25

25

10

2, 3, 4 15,16,20,25,30,32,40,50

85

42

42

20

100

50

50

25

2, 3, 4

AC440V
AC460V

Thermal magnetic
Fixed Adjustable Electronic

AC220V
AC240V

UCB100R

2, 3, 4

15,16,20,25,30,32,40,50,60,63,75,80,100,125

50

30/25

25

10

UCB100S

2, 3, 4

15,16,20,25,30,32,40,50,60,63,75,80,100,125

65

42/36

35

18

UCB100H 2, 3, 4 15,16,20,25,30,32,40,50,60,63,75,80,100,125

85

42

42

20

UCB100L

100

50

50

25

UCB160H 2, 3, 4 100,125,160

85

42

42

20

UCB160L

100

50

50

25

UCB250R 2, 3, 4 125,150,160,175,200,225,250

35

25/18

18

7.5

UCB250S

2, 3, 4 125,150,160,175,200,225,250

50

35/25

25

10

UCB250N 2, 3, 4 125,150,160,175,200,225,250

65

42/36

35

18

UCB250H 2, 3, 4 125,150,160,175,200,225,250

85

42

42

20

UCB250L

100

50

50

25

UCB400R 2, 3, 4 250,300,320,350,400

35

30

25

18

UCB400S

2, 3, 4 250,300,320,350,400

50

42

35

22

UCB400H 2, 3, 4 250,300,320,350,400

85

65

50

25

UCB400L

2, 3, 4 15,16,20,25,30,32,40,50,60,63,75,80,100,125
2, 3, 4 100,125,160

2, 3, 4 125,150,160,175,200,225,250

125

100

85

30

UCB630R 2, 3, 4 500,630

50

45

35

22

UCB630S

2, 3, 4 500,630

100

65

50

25

UCB630H 2, 3, 4 500,630

100

85

65

35

UCB630L

2, 3, 4 250,300,320,350,400

2, 3, 4 500,630

125

100

85

35

UCB800R 2, 3, 4 700,800

50

45

35

25

UCB800S

2, 3, 4 700,800

100

65

50

25

UCB800H 2, 3, 4 700,800

100

85

65

35

UCB800L

125

100

85

35

2, 3, 4 700,800

60/90/120 155 60
90/90/120 155 60
60/90/120 155 60
90/90/120 155 60
105/105/140 165 60

105/105/140 164 60

105/105/140 165 60

140/140/185 257 110

210/210/280 280 110

UCB1000S

3, 4

505-1000

100

100

75

40

210/280 370 110

UCB1000L

3, 4

505-1000

150

130

100

60

210/280 370 200

UCB1250S

3, 4

630-1250

100

100

75

40

210/280 370 110

UCB1250L

3, 4

630-1250

150

130

100

60

210/280 370 200

UCB1600S

640-1600

100

65

45

25

- The breaking capacity highlighted with blue and thick type is standard nominal value for each model in this catalogue.
2P breaker has same dimension with 3P breaker, but the middle pole is removed.

210

371 151

06

HYUNDAI HEAVY INDUSTRIES

LV & MV Circuit Breaker, Contactor & Overload Relay

UPB type / 125-630AF


Ampere
frame

125

160

250

400

630

Breaking capacity [Icu] (kA r.m.s.)

Model

Number
of poles

Rated current (A)

AC220V
AC240V

AC380V
AC415V

AC440V
AC460V

AC660V
AC690V

Trip mechanism & Characteristics

Dimensions (mm)

Thermal magnetic
Fixed Adjustable Electronic

Width Height Depth

UPB100S

3, 4

15,16,20,25,30,32,40,50,60,63,75,80,100,125

100

85

65

10

UPB100H

3, 4

15,16,20,25,30,32,40,50,60,63,75,80,100,1251)

130

100

85

10

UPB100L

3, 4

15,16,20,25,30,32,40,50,60,63,75,80,100,1251)

150

130

100

25

UPB100X

3, 4

15,16,20,25,30,32,40,50,60,63,75,80,100,125

200

150

150

25

1)

1)

1)

UPB160S

3, 4

100,125,160

100

85

65

10

UPB160H

3, 4

100,125,1601)

130

100

85

10

UPB160L

3, 4

100,125,1601)

150

130

100

25

UPB160X

3, 4

100,125,1601)

200

150

150

25

UPB250S

3, 4

125,150,160,175,200,225,2501)

100

85

65

10

UPB250H

3, 4

125,150,160,175,200,225,2501)

130

100

85

10

UPB250L

3, 4

125,150,160,175,200,225,2501)

150

130

100

25

UPB250X

3, 4

125,150,160,175,200,225,2501)

200

150

150

25

UPB400S

3, 4

200-400

100

85

65

10

UPB400H

3, 4

200-400

130

100

85

10

UPB400L

3, 4

200-400

150

130

100

25

UPB400X

3, 4

200-400

200

150

150

25

UPB630S

3, 4

320-630

100

85

65

10

UPB630H

3, 4

320-630

130

100

85

10

UPB630L

3, 4

320-630

150

130

100

25

UPB630X

3, 4

320-630

200

150

150

25

105/140 165 86.5

140/185 255 117

- The breaking capacity highlighted with blue and thick type is standard nominal value for each model in this catalogue.
1) Rated current of electronic types are as followings; UPB100: 50-125A UPB160: 63-160A UPB250: 100-250A

Motor protection / UPB type 125-250AF


Ampere
frame
125
250

Model

Number
of poles

UPB100H
UPB100L

Breaking capacity [Icu] (kA r.m.s.)

Dimensions (mm)

Rated current (A)

AC220V
AC240V

AC380V
AC415V

2.5,3.2,6.3,12.5,20,32,50,63,80,100

130

100

85

10

2.5,3.2,6.3,12.5,20,32,50,63,80,100

150

130

100

25

UPB250H

125,150,175,200,225

130

100

85

10

UPB250L

125,150,175,200,225

150

130

100

25

AC440V
AC460V

AC660V
AC690V

Width

Height

Depth

105

165

86.5

The breaking capacity highlighted with blue and thick type is standard nominal value for each model in this catalogue.

Q-class (for nuclear power plant application) / HBL type 100-225AF


Ampere
frame

100

225

Model

Number
of poles

Rated current (A)

Breaking capacity [Icu] (kA r.m.s.)

Characteristics

AC220V AC380V AC440V AC480V AC660V E1 class Motor


AC240V AC415V AC460V AC500V AC690V
protection

HBL103U

15,20,30,40,50,60,75,100

200

150

100

85

25

HBL103UQ

15,20,30,40,50,60,75,100

200

150

100

85

25

HBL103UM

2.5,3.2,6.3,12.5,20,32,50,63,80,100

200

150

100

85

25

HBL103UMQ

2.5,3.2,6.3,12.5,20,32,50,63,80,100

200

150

100

85

25

HBL203U

125,150,175,200,225

200

150

100

85

25

HBL203UQ

125,150,175,200,225

200

150

100

85

25

HBL203UM

125,150,175,200,225

200

150

100

85

25

HBL203UMQ

125,150,175,200,225

200

150

100

85

25

The breaking capacity highlighted with blue and thick type is standard nominal value for each model in this catalogue.

Dimensions (mm)
Width

Height

Depth

105

165

86.5

www.hyundai-elec.com

MCCB

UCD

Ampere
frame

Model

Number Rated
of poles current (A)

Dimensions (mm)
Width

Height

Depth

90

155

60

50

UCD50H

50

100

UCD100S

100

125

UCD100H

125

160

UCD160H

160

105

165

UCD250S

250

105

164

UCD250H

250

105

165

60

400

UCD400S

400

140

257

110

630

UCD630S

630

250

800

UCD800S

800

1000

UCD1000S

1000

1250

UCD1250S

1250

MC

UAB100S

Switch disconnector / 50-1250AF


Type

MINIATURE

Type

Ampere
frame

ACB

UCB250L

Model

Number Rated
of poles current (A)

UAD50C

UAD50S

50

100

UAD100R

100

60

125

UPD100S

125

60

160

UPD160S

160

250

UPD250S

250

400

UPD400S

400

630

UPD630S

630

210

280

110

210

370

110

UAD

UPD

50

VC

VCB

UPB400X

Dimensions (mm)
Width

Height

Depth

75

130

60

105

165

86.5

140

255

117

50

Miniature type / 30-100AF


Type

Model
Ampere
Number
Molded
case
Earth leakage of poles
frame

Rated current (A)

circuit breaker circuit breaker

UMB
UMG

30

50

30
UDB
UDG

50

100

ated residual
current [In]
(mA) for ELCB

Breaking capacity [Icu] (kA r.m.s.)


AC220V
AC240V

AC440V
AC460V

Width

Height

Depth

33

70

57

35

80

60

50/75

96

60

75/75

96

60

UMG30R

15,20,30

15, 30

2.5

UMB30S

UMG30S

15,20,30

15, 30

UMB30H

UMG30H

15,20,30

15, 30

10

UMB50S

UMG50S

15,20,30,40,50

15, 30

UMB50H

UMG50H

15,20,30,40,50

15, 30

10

UDB30S

UDG30S

2, 3

3,5,10,15,20,30

15, 30

2.5

2.5

UDB30H

UDG30H

2, 3

2.5

2.5

UDB50S

UDG50S

2, 3

UDB50H

UDG50H

2, 3

5,10
15,20,30
5,10,15,20,30,40,50
5,10
15,20,30,40,50

15, 30
15, 30
15, 30

Dimensions (mm)

AC380V
AC415V

UMB30R

10

2.5

2.5
2.5

2.5

10

UDB100S UDG100S

2, 3

15,20,30,40,50,60,75,100

30, 100

2.5

2.5

UDB100H UDG100H

2, 3

15,20,30,40,50,60,75,100

30, 100

10

- KS certified products. English nameplate and 50Hz marking are not available.
- The breaking capacity highlighted with blue and thick type is standard nominal value for each model in this catalogue.
2P breaker has same dimension with 3P breaker, but the middle pole is removed.

07

08

HYUNDAI HEAVY INDUSTRIES

LV & MV Circuit Breaker, Contactor & Overload Relay

Accessories

Interpole barrier [ TQQ ]

Terminal cover [ TCF ]

DIN-rail adapter [ DRA ]

Cage terminal block [ CTB ]

Plug-in mounting base [ TDM ]

Auxiliary switch [ AUX ]

Trip alarm switch [ ALT ]

Shunt trip [ SHT ]


Motor operator [ MOT ]

Under voltage trip [ UVT ]

Surface type operating handle [ TFG ]

Extended type operating handle [ TFH ]

Cage terminal block [ CTB ]

Terminal cover [ TCF ]

Interpole barrier [ TQQ ]

The applicable accessories of each MCCB are not same as above. For exact application to each MCCB, please reter to product catalogue.

www.hyundai-elec.com

MCCB

MINIATURE

MC

ACB

VC

Hi-Series
Fixed thermal type
Frame
30
50
60
100

225

400

600

800

Model
HiBS30
HiBH30
HiBE50
HiBS50
HiBH50
HiBE60
HiBS60
HiBE100
HiBS100
HiBH100
HiBE225
HiBS225
HiBH225
HiBE400
HiBS400
HiBH400
HiBL400
HiBE600
HiBS600
HiBH600
HiBL600
HiBE800
HiBS800
HiBH800
HiBL800

Number of
poles
2, 3
2, 3
2, 3, 4
2, 3, 4
2, 3, 4
2, 3, 4
2, 3, 4
2, 3, 4
2, 3, 4
2, 3, 4
21), 3, 4
21), 3, 4
21), 3, 4
21), 3, 4
21), 3, 4
21), 3, 4
21), 3, 4
21), 3, 4
21), 3, 4
21), 3, 4
21), 3, 4
21), 3, 4
21), 3, 4
21), 3, 4
21), 3, 4

Rated current (A)


3, 5, 10, 15, 20, 30
5, 10, 15, 20, 30
5, 10, 15, 20, 30, 40, 50
5, 10, 15, 20, 30, 40, 50
15, 20, 30, 40, 50
5, 10, 15, 20, 30, 40, 50, 60
5, 10, 15, 20, 30, 40, 50, 60
5, 10, 15, 20, 30, 40, 50, 60, 75, 100
15, 20, 30, 40, 50, 60, 75, 100
15, 20, 30, 40, 50, 60, 75, 100
125, 150, 175, 200, 225
125, 150, 175, 200, 225
125, 150, 175, 200, 225
250, 300, 350, 400
250, 300, 350, 400
250, 300, 350, 400
250, 300, 350, 400
500, 600
500, 600
500, 600
500, 600
700, 800
700, 800
700, 800
700, 800

Breaking capacity [Icu] (kA r.m.s.)


220/240V
10
25
10
25
50
10
25
25
50
65
35
50
65
35
50
85
125
50
100
100
125
50
100
100
125

380/415V
7.5/5
14/10
7.5/5
14/10
30/25
7.5/5
14/10
14/10
30/25
42/36
25/18
35/25
42/36
30
42
65
100
45
65
85
100
45
65
85
100

600V
2.5
5
2.5
5
10
2.5
5
5
10
18
7.5
10
18
18
22
25
30
22
25
35
35
25
25
35
35

HiBS103

Adjustable thermal type


Frame
50

100

225
250

Model
HiBL50NT
HiBX50NT
HiBS100J
HiBH100J
HiBL100NT
HiBX100NT
HiBL225NT
HiBX225NT
HiBE250J
HiBS250J
HiBH250J

Number of
poles
3, 4
3, 4
2, 3, 4
3, 4
3, 4
3, 4
3, 4
21), 3, 4

Rated current (A)


15, 20, 30, 40, 50
15, 20, 30, 40, 50
12.5-16, 16-20, 20-25, 25-32
32-40, 40-50, 50-63, 63-80, 80-100
15, 20, 30, 40, 50, 60, 75, 100
15, 20, 30, 40, 50, 60, 75, 100
125, 150, 175, 200, 225 (250)2)
125, 150, 175, 200, 225
100-125, 125-160, 160-200
200-250

Breaking capacity [Icu] (kA r.m.s.)


220/240V
125
150
50
65
125
150
125
150
35
50
65

380/415V
85
130
30/25
42/36
85
130
85
130
25/18
35/25
42/36

600V
35
65
10
18
35
65
35
65
7.5
10
18

HiBL203NE

Electronic type
Frame

Model

Number of
poles

50
100
225

HiBL50NE
HiBL100NE
HiBL225NE
HiBS400NE
HiBL400NE
HiBX400NE
HiBS600NE
HiBL600NE
HiBX600NE
HiBS800NE
HiBL800NE
HiBX800NE
HiBS1000NE
HiBL1000NE
HiBS1200NE
HiBL1200NE

3, 4
3, 4
3, 4
3, 4
3, 4
3, 4
3, 4
3, 4
3, 4
3, 4
3, 4
3, 4
3, 4
3, 4
3, 4
3, 4

400

600

800
1000
1200

Rated current (A)


20-50
40-100
90-225 (250)2)
200-400
200-400
200-400
302-600 (630)3)
302-600 (630)3)
302-600 (630)3)
405-800
405-800
405-800
505-1000
505-1000
605-1200
605-1200

Breaking capacity [Icu] (kA r.m.s.)


220/240V
125
125
125
85
125
150
100
125
150
100
125
150
100
150
100
150

1) 2 pole has same dimension with 3 pole, but middle pole is removed.
2) 250A for HiBL225NT and HiBL225NE is non-standard and available on special request.
3) 630A for HiBS600NE, HiBL600NE and HiBX600NE is non-standard and available on special request.

380/415V
85
85
85
50
85
130
65
85
130
65
85
130
100
130
100
130

600V
35
35
35
30
35
65
35
42
65
35
42
65
50
65
50
65

HiBS803NE

09

VCB

10

HYUNDAI HEAVY INDUSTRIES

LV & MV Circuit Breaker, Contactor & Overload Relay

Miniature Series
Miniature Circuit Breaker [ MCB ]
Miniature Switch Disconnector [ MSD ]

Residual Current Circuit Breaker [ RCCB, RCBO ]


Mini Breaker [HBD, HiBC]

HYUNDAI Miniature Series are the perfect solution to protect electric overload, short circuit
and earth leakage in the household and commercial installations.
With consistent and elegant appearances, the Hyundai Miniature Series provide various selection, easy
installation, economic benefit and high reliability based on international standard IEC.
Qualified Standard & Approval
Standard

IEC 60898

IEC 61009

IEC 60947-2

IEC 60947-3

IEC 61008

Approval

ISO 18001, 14001, 9001 BV


CE

GOST-R

KEMA

TSE

HiBD63-N

Miniature Circuit Breaker

HiRC63-N

HiRO40

HBD51h

HiBD125

HiBD63h

HiBD63-N

HiBD63-NS

HiBD63-S

HiBD63-E

IEC/EN60947-2

IEC/EN60898

IEC/EN60898

IEC/EN60898

IEC/EN60898

IEC/EN60898

Number of poles (P)

1, 2, 3, 4,
1+N, 3+N

1, 2, 3, 4,
1+N, 3+N

1, 2, 3, 4,
1+N, 3+N

1+N
(1 pole size)

1, 2, 3, 4

1, 2, 3, 4

Rated current [In] (A)

63, 80, 100, 125

1, 2, 3, 4, 5, 6,
10, 13, 15, 16, 20,
25, 32, 40, 50, 63

1, 2, 3, 4, 5, 6,
10, 13, 15, 16, 20,
25, 32, 40, 50, 63

1, 2, 3, 4, 6,
10, 13, 16,
20, 25, 32, 40

1, 2, 3, 4, 5, 6,
10, 13, 15, 16,
20, 25, 32, 40

1, 2, 3, 4, 5, 6,
10, 13, 15, 16,
20, 25, 32, 40

Model
Standard

Rated insulation voltage [Ui] (V)


Rated operational voltage [Ue] (V)
Rated impulse withstand voltage [Uimp] (kV)

AC500

AC500

AC500

AC500

AC500

AC500

AC240/4151)

AC240/4151)

AC240/4151)

AC240

AC240/4151)

AC240/4151)

4.5

10

10

6(1-25A),
4.5(32-40A)

AC220/240V

10

10

6(1-25A),
4.5(32-40A)

4.5

Rated
IEC60898 AC380V
short-circuit
breaking
AC400/460V
capacity [Icu]
AC220/240V
(kA r.m.s.)
IEC60947-2
AC400/460V

10

10

6(1-25A),
4.5(32-40A)

4.5

10

10

6(1-25A),
4.5(32-40A)

4.5

3
6

Rated conditional short-circuit current (kA)

Ics (=% Icu)


Tripping characteristic (curve)
Durability
(times)

Accessories

15

15

10

10

7.5

15

15

10

10

7.5

75

75

100

100

100

100

B, C, D

B, C, D

B, C, D

B, C

B, C

B, C

Electrical

10,000

10,000

10,000

10,000

10,000

10,000

Mechanical

20,000

20,000

20,000

20,000

20,000

20,000

operating frequency per hour

120

120

120

120

120

120

Auxiliary switch

Trip alarm switch

Auxiliary & Trip alarm switch

Shunt trip

Shunt trip & Auxiliary switch

Under voltage trip

1) AC415V is not applicable for 1P and 1P+N breaker.

11

www.hyundai-elec.com

MINIATURE

MCCB

MC

ACB

VC

VCB

Miniature Switch Disconnector


Model
Standard
Number of poles (P)
Rated current [In] (A)
Rated insulation voltage [Ui] (V)

Rated operational voltage [Ue] (V)

HiSD125
IEC/EN60947-3
1, 2, 3, 4
16, 32, 63, 100, 125
AC500

AC240/4151)

Rated impulse withstand voltage [Uimp] (kV)


Electrical
Durability (times)
Mechanical
operating frequency per hour

4
10,000
20,000
120

1) AC415V is not applicable for 1P breaker.

Residual Current Circuit Breaker


Model
Standard
Current characteristic (type)
Number of poles (P)
Rated current [In] (A)
Rated residual current [In] (mA)
Rated insulation voltage [Ui] (V)
Rated operational voltage [Ue] (V)
Rated impulse withstand voltage [Uimp] (kV)
Rated conditional short-circuit current (kA)
AC220/240V
Rated
IEC60898
AC380V
short-circuit
[Icu] (kA r.m.s.)
breaking
AC400/460V
capacity
Ics (=% Icu)
Tripping characteristic (curve)
Electrical
Durability
Mechanical
(times)
Operating frequency per hour

HiRC100-N

HiRC63-N

HiRC63

HiRO40

HiRD125

HiRD63

HiRD32

IEC/EN61008 IEC/EN61008 IEC/EN61008 IEC/EN61009 IEC/EN61009 IEC/EN61009 IEC/EN61009


AC, A
AC, A
AC
AC
AC
AC
AC
2(1+N), 4(3+N) 2(1+N), 4(3+N) 2(1+N), 4(3+N)
1+N
1+N, 2, 3, 3+N, 4 1+N, 2, 3, 3+N, 4 1+N, 2, 3, 3+N, 4
16, 25, 32,
16, 25, 32,
1, 3, 5, 6, 10,
1, 2, 3, 4, 5, 6, 10, 13,
63, 80, 100
63, 80, 100, 125
40, 50, 63
40, 63
40, 63
16, 20, 25, 32, 40
15, 16, 20, 25 , 32
30, 100, 300,
500
AC500
AC240/4151)
5
10
10,000
20,000
120

10, 30, 100,


10, 30, 100,
300, 500
300, 500
AC500
AC500
AC240/4151)
AC240/4151)
5
5
6
6
10,000
10,000
20,000
20,000
240(16,25A),
240(16,25A),
120(32,40,63A) 120(32,40,63A)

10, 30, 100,


300, 500
AC500
AC240
5
4.5
4.5
4.5
4.5
75
C
10,000
20,000

10, 30, 100,


300, 500
AC500
AC240/4151)
5
10
10
10
10
75
B, C, D
10,000
20,000

10, 30, 100,


300, 500
AC500
AC240/4151)
5
6
6
6
6
75
B, C, D
10,000
20,000

10, 30, 100,


300, 500
AC500
AC240/4151)
5
6
6
6
6
75
B, C, D
10,000
20,000

120

120

120

120

1) AC415V is not applicable for 2P(1P+N) and 1P+N breaker.

Mini Breaker
Model
Standard
Number of poles (P)
Rated current (A)
Rated insulation voltage [Ui] (V)
Rated operational voltage [Ue] (V)
Rated impulse withstand voltage [Uimp] (kV)
Rated
Ultimate [Icu] AC220/240V, 50-60Hz
short-circuit (kA r.m.s.)
DC125V
breaking
capacity
Service [Ics] % of [Icu]
Terminal connection
Model
Standard
Number of poles (P)
Rated current (A)
Rated insulation voltage [Ui] (V)
Rated operational voltage [Ue] (V)
Rated impulse withstand voltage [Uimp] (kV)
Rated
Ultimate [Icu] AC220/240V, 50-60Hz
short-circuit (kA r.m.s.)
DC125V
breaking
capacity
Service [Ics] % of [Icu]
Terminal connection
1) AC460V is not applicable for 1P breaker.

HBD51D HBD52D HBD53D HBD51HD HBD52HD HBD53HD HBD101HD HBD102HD HBD103HD HBD101HDC HBD102HDC HBD103HDC

IEC60947-2
1
2
3
10, 15, 20, 30, 40, 50
AC460
AC240/4601)
6
5
5
50
Screw
HBD51

HBD52

HBD53

IEC60947-2
1
2
3
10, 15, 20, 30, 40, 50
AC460
AC240/4601)
6
5
5
50
Screw

IEC60947-2
1
2
3
10, 15, 20, 30, 40, 50
AC460
AC240/4601)
6
10
10
50
Screw

IEC60947-2
IEC60947-2
1
2
3
1
2
3
10,15,20,30,40,50,60,70,80,90,100 10,15,20,30,40,50,60,70,80,90,100
AC460
AC460
AC240/4601)
AC240/4601)
6
6
10
10
10
10
50
50
Screw
Cage lug

HBD51H HBD52H HBD53H HBD101H HBD102H HBD103H HBD101HC HBD102HC HBD103HC

IEC60947-2
1
2
3
10, 15, 20, 30, 40, 50
AC460
AC240/4601)
6
10
10
50
Screw

IEC60947-2
IEC60947-2
1
2
3
1
2
3
10,15,20,30,40,50,60,70,80,90,100 10,15,20,30,40,50,60,70,80,90,100
AC460
AC460
AC240/4601)
AC240/4601)
6
6
10
10
10
10
50
50
Screw
Cage lug

12

HYUNDAI HEAVY INDUSTRIES

LV & MV Circuit Breaker, Contactor & Overload Relay

Contactor & Overload Relay


HYUNDAI Contactor & Overload Relay employs a modular design, which allows quick and simple mounting of
auxiliary contact blocks, timers, mechanical latching blocks, etc.
With highly advanced design for industrial applications such as motor control centers,
the HYUNDAI contactor is appropriate for various control systems.
It is also favored by shipyards and power plants whose criteria includes high reliability and performance.

Qualified Standard & Approval


Standard

Approval

IEC 60947

ISO 18001, 14001, 9001

EN 60947

CE (Community European / TU V Rheinland)

UL 508

KERI

BS 47794, BS 5424, BS 4941

KS

VDE 0660

UL / C-UL

DNV

TSE

KS C4504

GOST-R

JISC 8328, JEM 1038

CCC

..

KR, ABS, BV, NK, LR

U-Series

UMC9

UMC225

Magnetic Contactor
Model
UMC9

Durability

Capacity (IEC60947, AC-3 [Ie], kW/A)


AC200 /240V AC380 / 440V AC500 / 550V AC660 /690V
2.5/9
4/9
4/7
5.5/6

Auxiliary
contact
(standard)

Dimensions
(WxHxD, mm)

1NO or 1NC

44x75x80(AC)
44x75x112(DC)

AC,DC

45x83x94(AC)
45x83x127(DC)

AC,DC

2NO+1NC
(DC only)

55x106x111

AC,DC

2NO+1NC
(DC only)

70x140x128

AC/DC

2NO+2NC

103x155x146

AC/DC

2NO+2NC

138x204x174

AC/DC

2NO+2NC

163x243x203

AC/DC

2NO+2NC

276x314x253

Operation
Mechanical current
25,000
AC,DC
25,000

(at AC440V, 1000 times)

AC1000V
-

Electrical
2,500

7.5/9

2,500

UMC12

3.5/12

5.5/12

7.5/12

UMC18

4.5/18

7.5/18

8.5/15

7.5/9

2,500

15,000

UMC25

5.5/25

11/25

15/22

15/18

2,500

15,000

UMC32

7.5/32

15/32

18.5/28

18.5/22

2,000

15,000

UMC40

11/40

18.5/40

22/32

22/23

2,000

15,000

UMC50

15/50

22/50

30/43

30/28

2,000

15,000

UMC65

18.5/65

30/65

33/60

33/35

2,000

15,000

UMC75

22/75

37/75

37/64

37/42

2,000

10,000

UMC85

25/85

45/85

50/75

45/45

2,000

10,000

UMC100

30/100

55/100

50/85

45/65

2,000

10,000

UMC115

37/115

60/115

59/100

55/65

65/50

1,000

5,000

UMC130

40/130

65/130

70/120

75/82

75/54

1,000

5,000

UMC150

45/150

75/150

90/140

90/120

90/66

1,000

5,000

UMC185

55/185

90/185

110/180

110/120

110/78

1,000

5,000

UMC225

75/225

132/225

132/200

132/150

132/96

1,000

5,000

UMC265

80/265

147/265

150/225

160/173

160/113

1,000

5,000

UMC300

90/300

160/300

200/273

200/220

200/141

1,000

5,000

UMC400

125/400

220/400

250/300

250/300

250/178

1,000

5,000

UMC500

140/500

250/500

300/426

335/360

275/192

50

500

UMC630

190/630

330/500

330/500

400/412

300/213

50

500

UMC800

220/800

440/800

500/720

500/630

400/284

50

500

www.hyundai-elec.com

MCCB

MC

MINIATURE

ACB

VC

VCB

Thermal Overload Relay


Model

Rated
current
(A)

Auxiliary contact
(standard)
Dimensions
(WxHxD, mm)

UTH12

UTH32

0.12-0.15-0.18
0.18-0.22-0.26
0.12-0.15-0.18 0.25-0.3-0.35
0.18-0.22-0.26 0.34-0.42-0.5
0.25-0.3-0.35
0.5-0.6-0.7
0.34-0.42-0.5
0.6-0.75-0.9
0.5-0.6-0.7
0.8-1-1.2
0.6-0.75-0.9
1.1-1.35-1.6
0.8-1-1.2
1.5-1.8-2.1
1.1-1.35-1.6
2-2.5-3
1.5-1.8-2.1
2.8-3.5-4.2
2-2.5-3
3-4-5
2.8-3.5-4.2
4-5-6
3-4-5
5.6-6.8-8
4-5-6
6-7.5-9
5.6-6.8-8
8-10-12
6-7.5-9
12-15-18
8-10-12
15-18.5-22
17-21-25
22-27-32

UTH65

UTH100

7-8.5-10
8-10-12
12-15-18
15-18.5-22
17-21-25
22-27-32
28-34-40
34-42-50
45-55-65

13

UTH150

UTH265

UTH400

UTH800

17-21-25
22-27-32
28-34-40
34-42-50
45-55-65
52-63-75
59-72-85
70-85-100

48-64-80
69-92-115
78-104-130
90-120-150

48-64-80
69-92-115
78-104-130
90-120-150
111-148-185
135-180-225
159-212-265

90-120-150
111-148-185
135-180-225
159-212-265
180-240-300
240-320-400

300-400-500
378-504-630
480-640-800

1NO+1NC

1NO+1NC

1NO+1NC

1NO+1NC

1NO+1NC

1NO+1NC

1NO+1NC

1NO+1NC

45x79x76

45x81x91

55x94x105

70x108x123

180x159x187

180x185x185

180x205x185

245x223x197

UMC9

Applied
contactor

UMC18
UMC25
UMC32

UMC40
UMC50
UMC65

UMC75
UMC85
UMC100

UMC115
UMC130
UMC150

UMC185
UMC225
UMC265

UMC300

UMC12

UMC400

UMC500
UMC630
UMC800

Separate mounting
block (option)

UTHMB12

UTHMB32

UTHMB65

UTHMB100

14

HYUNDAI HEAVY INDUSTRIES

LV & MV Circuit Breaker, Contactor & Overload Relay

Contactor & Overload Relay


Control Relay
Model

Auxiliary contact

UMX04

0NO+4NC

UMX13

1NO+3NC

UMX22

2NO+2NC

UMX31
UMX40

Operation current

Model

Auxiliary contact

UMT04

0NO+4NC

UMT13

1NO+3NC

UMT22

2NO+2NC

3NO+1NC

UMT31

3NO+1NC

4NO+0NC

UMT40

4NO+0NC

AC

Operation current

DC

Auxiliary Contact Block


Model

Auxiliary contact

UAB02

0NO+2NC

UAB11

1NO+1NC

UAB20

2NO+0NC

UAB04

0NO+4NC

UAB13

1NO+3NC

UAB22

2NO+2NC

UAB31

3NO+1NC

UAB40

4NO+0NC

UAL65

1NO+1NC

UMC9-65

UAL100

1NO+1NC

UMC75-100

UAL400

1NO+1NC

UMC115-800

UMC9-100
UMX, UMT

Mechanical Interlock Unit


Model

Mounting position

Applicable product

Front

Side

Electronic Timer Block

Applied contactors

Model

Control voltage

Applicable product

UTL65 S

UMC9-65

UTL100

UMC75-100

UET1
UET2

AC/DC90-240V
AC/DC24-60V

UMC9-100,
UMX, UMT

UTL265

UMC115-265

UTL400

UMC300-800

Surge Absorber

Mechanical Latching Block


Model

Control voltage

Applicable product

Item

Model

AC/DC24
AC/DC48
ULB100

AC/DC100-125
AC/DC200-240

Control voltage
AC24-48V

UMC9-100,
UMX, UMT

URC32

AC240-380V

RC-unit

AC440

AC110-220V

Applicable product
UMC9-32,
UMX

AC24-48V
URC100

AC110-220V

UMC40-100

AC240-380V
Clamping diode

UCD100

DC24-125V

UMT

www.hyundai-elec.com

MCCB

MINIATURE

MC

ACB

VC

Accessories
1. Contactor UMC
2. Front safety cover
3. Auxiliary contact block (Front mounting) UAB
4. Auxiliary contact block (Side mounting) UAL
5. Mechanical latching block ULB
6. Electronic timer block UET
7. Mechanical interlock unit UTL
8. Surge absorber URC/UCD
9. Thermal overload relay UTH

4
1

7
4

2
3

The applicable accessories of each contactor are not same as above. For exact application to each contactor, please refer to product catalogue.

Front Safety Cover


Model

Applicable product

UMC100IC

UMC9-100, UMX, UMT

UMC150IC

UMC115-150

UMC265IC

UMC185-265

UMC400IC

UMC300-500

UMC800IC

UMC630-800

Feature

Moving contacts

Item

Model

Main contact

UMCTIP

Terminal
protection
cover

UMC_PC

Spare Part
Feature

Item

Model

Coil

UMCOL

Fixed contacts

Main
terminal cover

Arc chute

UMCHT

Coil
terminal cover
Auxiliary contact
terminal cover

15

VCB

16

HYUNDAI HEAVY INDUSTRIES

LV & MV Circuit Breaker, Contactor & Overload Relay

Contactor & Overload Relay


Hi-Series
HiMC22 + HiTH22

Magnetic Contactor

HiMC130

Capacity (AC3, kW/A)

Model
HiMC9
HiMC12
HiMC18
HiMC22
HiMC32
HiMC40
HiMC50
HiMC65
HiMC80
HiMC90
HiMC110, HiMC110B 2)
HiMC130
HiMC150, HiMC150B 2)
HiMC180
HiMC220
HiMC260, HiMC260B 2)
HiMC300
HiMC400
HiMC500
HiMC630
HiMC800

200-240V

380-440V

500-550V

660-690V

1,000V

2.2/10
3.7/13
4.5/18
5.5/22
7.5/32
11/40
15/50
18.5/70
22/80
25/90
30/110
37/130
45/150
55/180
63/220
75/260
90/300
125/400
140/500
190/630
220/800

4/9
5.5/12
7.5/18
11/22
15/32
18.5/40
22/50
30/65
37/80
45/90
55/110
65/130
75/150
90/180
110/220
132/260
160/300
220/400
250/500
330/630
440/800

4/7
7.5/12
8.5/15
15/22
18.5/28
22/32
30/45
37/60
45/64
50/80
60/110
70/120
90/140
110/180
132/200
150/220
160/273
220/350
300/426
330/500
500/720

5.5/7
7.5/9
7.5/9
15/18
18.5/22
22/26
25/31
37/44
45/52
50/60
55/65
60/70
90/100
110/120
132/150
160/173
200/220
250/300
335/360
400/412
500/630

65/50
75/54
90/66
110/78
132/96
160/113
200/141
250/178
275/192
300/213
400/284

Auxiliary contact

Operation current

1NO+1NC
1NO+1NC
1NO+1NC
1NO+1NC
2NO+2NC
2NO+2NC
2NO+2NC1)
2NO+2NC1)
2NO+2NC1)
2NO+2NC1)
2NO+2NC1)
2NO+2NC1)
2NO+2NC1)
2NO+2NC1)
2NO+2NC1)
2NO+2NC1)
2NO+2NC1)
2NO+2NC1)
2NO+2NC1)
2NO+2NC1)
2NO+2NC1)

AC, DC
AC, DC
AC, DC
AC, DC
AC, DC
AC, DC
AC, DC
AC, DC, AC/DC
AC, DC, AC/DC
AC, DC, AC/DC
AC, DC, AC/DC
AC, DC, AC/DC
AC, DC, AC/DC
AC, DC, AC/DC
AC, DC, AC/DC
AC, DC, AC/DC
AC, DC, AC/DC
AC, DC, AC/DC
AC, DC, AC/DC
AC, DC, AC/DC
AC, DC, AC/DC

1) The auxiliary contact for DC is 2NO+1NC.


2) HiMC110B, HiMC150B, HiMC260B: Compact type

HiMK

Capacitor Switching Contactor


Rating of 3-phase capacitor 50-60Hz
(at ambient temperature 55C)
Model
(AC operation)

HiMK9 21
HiMK9 12
HiMK12 21
HiMK12 12
HiMK18 21
HiMK18 12
HiMK22 21
HiMK22 12
HiMK32 32
HiMK32 23
HiMK40 32
HiMK40 23
HiMK50 32
HiMK50 23

Composed devices

Max. power

Contactor

Capacitor switching unit

AC-6b
200V
kVAR

230V
240V
kVAR

400V
415V
kVAR

6.7

6.7

440V
kVAR

500V
550V
kVAR

690V
kVAR

9.7

9.7

14

14

HiMC9

12.5

12.5

18

18

HiMC12

(AC operation)

8.5

16.7

16.7

24

24

HiMC18

10

10

18

18

26

26

HiMC22

16

27.5

External size

Auxiliary

8.5

14

Dimension

30

34

45

HiMC32

20

20

30

33.3

48

48

HiMC40

21

24

40

45

50

65

HiMC50

Model
HiAD50 10
HiAD50 01
HiAD50 10
HiAD50 01
HiAD50 10
HiAD50 01
HiAD50 10
HiAD50 01
HiAD50 10
HiAD50 01
HiAD50 10
HiAD50 01
HiAD50 10
HiAD50 01

NO
NC
(53-54) (51-52)

WxHxD
(mm)

1
1
1
1
1

44x166x123

1
1
1
1
1
1

63x166x123

1
1
1

70x178x136

17

www.hyundai-elec.com

MCCB

HiTH22

Thermal Overload Relay


Model

MC

MINIATURE

ACB

HiTH90

VC

VCB

HiTH130

HiTH22

HiTH40

HiTH50

HiTH90

HiTH130

HiTH220

HiTH300

HiTH500

HiTH800

0.12-0.18
0.18-0.26
0.25-0.35
0.34-0.5
0.5-0.7
0.6-0.9
0.8-1.2
1.1-1.6
1.5-2.1
2-3
2.8-4.2
3-5
4-6
7-10
9-13
12-18
16-22

7-10
9-13
12-18
16-22
18-26
24-32
28-40

18-26
24-32
28-40
36-50

28-40
36-50
45-65
60-80
70-90

48-80
78-130

78-130
108-180
132-220

132-220
180-300

180-300
240-400
300-500

378-630
480-800

Applied
contactor

HiMC9
HiMC12
HiMC18
HiMC22

HiMC32
HiMC40

HiMC50

HiMC65
HiMC80
HiMC90
HiMC110B

HiMC110
HiMC130
HiMC150B

HiMC150
HiMC180
HiMC220
HiMC260B

HiMC260
HiMC300

HiMC400
HiMC500

HiMC630
HiMC800

Separate mounting
block (option)

ITHMB22

ITHMB40

ITHMB50

ITHMB90

Rated
current
(A)

Digital Motor Protection Relay


Function
Model

Deluxe type

Standard type

Standard Type

Wiring of main circuit

Over
current

Phase
failure

Phase
Restriction
unbalance

Reverse
phase

HiMP22K I
HiMP40K I
HiMP50K I

Inverse

HiMP150K I
HiMP300K I

Inverse

HiMP22K N
HiMP40K N
HiMP50K N

Inverse/
Reverse

HiMP150K N
HiMP300K N

Inverse/
Reverse

Allowable current partition

Pin

Screw

Tunnel

HiMP22: 0.3-1.5A, 1-5A,


4.4-22A
HiMP40: 8-40A
HiMP50: 10-50A

HiMP150: 30-150A
HiMP300: 60-300A

HiMP22: 0.3-1.5A, 1-5A,


4.4-22A
HiMP40: 8-40A
HiMP50: 10-50A

HiMP150: 30-150A
HiMP300: 60-300A

Deluxe Type
Function
Model
HiMP60K S
HiMP60K I
HiMP60K Z

Wiring of main circuit

Over
current

Under
curren

Phase
failure

Phase
Restriction
unbalance

Reverse
phase

Short
circuit

Leakage
current

Screw

Tunnel

Allowable current
partition

0.5-6A, 5-60A

18

HYUNDAI HEAVY INDUSTRIES

LV & MV Circuit Breaker, Contactor & Overload Relay

Air Circuit Breaker


Designed for both industrial and marine application, HYUNDAI Air Circuit Breakers have
innovated structure, various protection, and reliable performance.

Qualified Standard & Approval


Standard

Approval

IEC 60947-2

ISO 18001, 14001, 9001

EN 60947-2

CE (Community European / TU V Rheinland)

AS 3972-2

KERI

NEMA PUB NO. SG3

KS

ANSI C37.13

GOST-R

VDE 0660

CCC

GOST-R 50030.2-99 9

KR, GL, LR, ABS, BV, NK

..

GOST-R 50030.1-2000

UAN Type

UAN Type
Model
Rated current (A)

UAN06

UAN08

UAN10

UAN12

UAN16

UAN20

UAN32

UAN40

UAN50

630

800

1,000

1,250

1,600

2,000

3,200

4,000

5,000

Number of pole

3, 4

Utilization category

Rated insulation voltage (Ui) (V)

AC1,000

Rated operation voltage (Ue) (V)

AC690

Rated breaking
capacity (kA sym) [Icu]
with Inst.
Icu=100% Ics
Rated making
capacity (kA peak) [Icm]
with Inst.
Icu=100% Ics

AC690V

65

65

65

65

65

65

85

85

85

AC500V

85

85

85

85

85

85

100

100

100

AC415V below

85

85

85

85

85

85

100

100

100

AC690V

143

143

143

143

143

143

187

187

187

AC500V

187

187

187

187

187

187

220

220

220

AC415V below

187

187

187

187

187

187

220

220

220

Rated impulse withstand voltage (Uimp) (kV)


Rated short-time withstand
current [Icw] (kA r.m.s.)

1 sec

Rated latching current (kA)

12
65

65

65

65

65

65

85

85

85

65

65

65

65

65

65

85

85

85

Total breaking time (sec)

0.05

Closing
Charging time (sec) max.
operating
Closing time (sec) max.
time
Dimensions (mm)
(3pole, Draw-out type)

10
0.04

Height

460

Width

328

Depth

405

460
399

656
439.2

www.hyundai-elec.com

MCCB

MINIATURE

MC

ACB

VC

VCB

HiAN and HiAH Type


Model

HiAN06

HiAN08

HiAN10

HiAN12

HiAN16

HiAN20

HiAN25

HiAN32

HiAN40

HiAN50

HiAN63

Rated current (A)


Number of pole
Utilization category
Rated insulation voltage (Ui) (V)
Rated operation voltage (Ue) (V)
Rated breaking
AC690V
capacity (kA sym) [Icu]
AC500V
with Inst.
Icu=100% Ics
AC415V below
Rated making
AC690V
capacity (kA peak) [Icm]
AC500V
with Inst.
Icu=100% Ics
AC415V below
Rated impulse withstand voltage (Uimp) (kV)

630

800

1,000

1,250

1,600

2,500

3,200

4,000

5,000

6,300

50
70
70
105
154
154

50
70
70
105
154
154

50
70
70
105
154
154

50
70
70
105
154
154

50
70
70
105
154
154

2,000
3, 4
B
AC1,000
AC690
65
70
85
143
154
187
8

65
85
85
143
187
187

65
85
85
143
187
187

85
100
100
187
220
220

100
120
120
220
291
291

100
120
120
220
291
291

65

65

65

65

65

70

85

85

75

100

100

65

65

65

65

65

70
0.04
10

85

85

75

100

100

43
65
51
76

43
65
51
76

43
65
51
76

49
72
58
85

49
72
58
85

60
87
69
100

63
92
76
110

65
96
83
120

Rated short-time withstand


current [Icw] (kA r.m.s.)

1 sec

Rated latching current (kA)


Total breaking time (sec)
Closing
Charging time (sec) max.
operating
Closing time (sec) max.
time
3pole, Fixed type
3pole, Draw-out type
Weight
(kg)
4pole, Fixed type
4pole, Draw-out type
Height
Dimensions (mm)
Width
(3pole, Draw-out type)
Depth

0.04

0.06
115

210

230

135

230
478

250

490
320

410

480

984

461.2

481

HiAS Type
Model

HiAS06

HiAS08

HiAS10

HiAS12

Rated current (A)


Number of pole
Utilization category
Rated insulation voltage (Ui) (V)
Rated operation voltage (Ue) (V)
Rated breaking
AC690V
capacity (kA sym) [Icu]
AC500V
with Inst.
Icu=100% Ics
AC415V below
Rated making
AC690V
capacity (kA peak) [Icm]
AC500V
with Inst.
Icu=100% Ics
AC415V below
Rated impulse withstand voltage (Uimp) (kV)

630

800

1,000

1,250

42
50
50
88.2
110
110

42
50
50
88.2
110
110

42
50
50
88.2
110
110

42

42

42

42

42

42

42

42

Rated short-time withstand


current [Icw] (kA r.m.s.)

1 sec

Rated latching current (kA)


Total breaking time (sec)
Closing
Charging time (sec) max.
operating
Closing time (sec) max.
time
3pole, Fixed type
3pole, Draw-out type
Weight
(kg)
4pole, Fixed type
4pole, Draw-out type
Height
Dimensions (mm)
Width
(3pole, Draw-out type)
Depth

HiAS16

HiAS20

HiAS25

HiAS32

2,000

2,500

3,200

50
65
65
105
143
143

50
65
65
105
143
143

50
65
65
105
143
143

42

50

50

50

42

50

50

50

49
72
58
85

60
87
69
100

63
92
76
110

65
96
83
120

1,600
3, 4
B
AC1,000
AC690
42
42
50
50
50
50
88.2
88.2
110
110
110
110
8

0.04
10
0.04
43
65
51
76

43
65
51
76

43
65
51
76

49
72
58
85
459

320

410
461.2

19

20

HYUNDAI HEAVY INDUSTRIES

LV & MV Circuit Breaker, Contactor & Overload Relay

Vacuum Contactor
HYUNDAI Vacuum Contactors are designed and manufactured for frequent
switchings, especially taking into account safety and quality assurance.
They are suitable for switching and controlling squirrel cage and
slipring motors, medium voltage loads and resistance furnaces,
and capacitors and transformers.
Qualified Standard & Approval
Standard

IEC 60470

Approval

ISO 18001, 14001, 9001

UL 347

KERI

NEMA ICS 3

UL, c-UL

KR, GL, LR, NK

UVC Type
Fixed type

Structure
Ratings

Draw-out type

X1 Without fuse holder

B1 B2 Without fuse holder

A1 With single fuse holder

D1 D2 With single fuse holder

Operating

Continuously energized

32C

34C

62C

64C

32C

34C

62C

64C

method

Latched

32L

34L

62L

64L

32L

34L

62L

64L

Rated insulation voltage (kV)

3.6

7.2

3.6

7.2

Rated operation voltage (kV)

3.3

6.6

3.3

6.6

Rated frequency (Hz)


Rated current (A)
Withstand
voltage

50/60
200

400

200

400

Impulse (kV)

60

Power frequency (1min, kV)

20

Control dielectric strength(min, kV)

lifetime

1 sec

6.3

30 sec

Continuously energized

1,000

(1,000 times)

Latched (1,000 times)

250
300

Control voltage (V)

AC/DC100-125, AC/DC200-230

Auxiliary contact
Motor (kW)
load capacity

400

4kA (O-3min-CO-3min-CO, 50MVA at 7.2kV)

Electrical lifetime (1,000 times)

Applicable

200

AC3

Breaking capacity

Mechanical

400

Utilization category

Short-time
current
[kA]

200

3a2b
750

1,500

1,500

3,000

750

1,500

1,500

3,000

Transformer (kVA)

1,000

2,000

2,000

4,000

1,000

2,000

2,000

4,000

Condensor (kVAR)

750

1,200

1,500

2,000

750

1,200

1,500

2,000

Weight without fuse(kg)

X1 19

B1 B2 33

B1 B2 35

A1 28

D1 D2 35

D1 D2 38

www.hyundai-elec.com

MCCB

MINIATURE

MC

VC

ACB

VCB

HCA Type
Structure
Ratings

Fixed type

Draw-out type

F Without fuse holder

B Without fuse holder

A With single fuse holder

D With single fuse holder

J With double fuse holder1)

H With double fuse holder1)

Operating

Continuously energized

32C

34C

62C

64C

82C

84C

32C

34C

62C

64C

82C

84C

method

Latched

32L

34L

62L

64L

82L

84L

32L

34L

62L

64L

82L

84L

Rated insulation voltage (kV)

3.6

7.2

12

3.6

7.2

12

Rated operation voltage (kV)

3.3

6.6

11

3.3

6.6

11

50/60

Rated frequency (Hz)


Rated current (A)
Withstand
voltage

200

400

200

400

400

200

400

45

60

75

Power frequency (1min, kV)

16

20

28

16

20

28

AC3

AC4

AC3

AC4

4kA (O-3min-CO-3min-CO)

1 sec

6.3

6.3

6.3

6.3

6.3

6.3

30 sec

2.4

2.4

2.4

2.4

2.4

2.4

1,000

1,000

1,000

1,000

1,000

1,000

250

250

250

250

250

250

2a2b2)

5a5b

Continuously energized
(1,000 times)

Latched (1,000 times)

300

Control voltage (V)

AC110/125/220, DC110/125/220

Auxiliary contact
Motor (kW)
load capacity

200

75

Electrical lifetime (1,000 times)

Applicable

400

60

Breaking capacity

lifetime

200

45

Utilization category

Mechanical

400

Impulse (kV)

Control dielectric strength(min, kV)

Short-time
current
[kA]

200

2a2b

2a2b

2)

750

1,500

1,500

3,000

3,000

6,000

750

1,500

1,500

3,000

3,000

6,000

Transformer (kVA)

1,000

2,000

2,000

4,000

4,000

8,000

1,000

2,000

2,000

4,000

4,000

8,000

Condensor (kVAR)

750

1,200

1,500

2,000

3,000

4,000

750

1,200

1,500

2,000

3,000

4,000

Weight without fuse(kg)

F 21

F 22

F 61

B 38

A 30

A 32

A 68

D 403)

D 433)

J 33

J 35

H 43

H 46

1) Double fuse holder is not applicable to 12kV.


2) In case of 3.6/7.2kV fixed type without fuse holder, 3a3b is standard.
3) The weight of 3.6/7.2kV draw-out type is based on F1 cradle.
4) The weight of 12kV draw-out type is measured without cradle.

3)

3)

B 41

3)

B 804)
D 834)

3)

21

22

HYUNDAI HEAVY INDUSTRIES

LV & MV Circuit Breaker, Contactor & Overload Relay

Vacuum Circuit Breaker


HYUNDAI Vacuum Circuit Breaker achieves the superior reputation with its extended life expectancy,
easy maintenance, and excellent performance for industrial facilities, power plants, and marine vessels.

Qualified Standard & Approval


Standard

Approval

IEC 62271-100, 60056

ISO 18001, 14001, 9001

ESB 150

KEMA

ANSI C37.09

KERI

KSC 4611

KR, GL

GOST-R 52565-06

HVF type

HVG type

IEC 62271-100
Withstand voltage

Type

Rated
(kV)
voltage (kV) Power-frequency/
Impulse

7.2

20/60

28/75
12

42/75

HVF

17.5

HVG

38 / 95

Rated
breaking
current(kA)

Model1)

Rated current (A)1)


400

630

1,250

2,000

2,500

3,150

4,000

25

HVF114

31.5

HVF115

40

HVF116

50

HVF117

25

HVF214

31.5

HVF215

40

HVF216

50

HVF217

25

HVF224

2)

31.5

2)

HVF225

40

HVF2262)

25

HVF314

31.5

HVF315

40

HVF316

24/25.8

50/125
(65/125) 2)

12.5

HVF611

25

HVF614

24

65/125

25

HVF6252)

36

70/170

25

HVF714

31.5

HVF705

36/40.5

95/190

31.5

HVF725

HVG109

12.5

HVG101

20

HVG113

25

HVG114

7.2

20/60

2)
2)

2)

1) Model number in the square "" shall be listed as below for the rated current according to applied standard.
- IEC standard: 1 630A 2 1,250A 4 2,000A 6 2,500A 7 3,150A 8 4,000A 9 400A
2) HVF224 , 225 , 226 , 611 , 614 , 625 , 725 are applicable to GOST-R standard.

www.hyundai-elec.com

MCCB

MC

MINIATURE

15kV

ACB

VCB

VC

38kV

ANSI C37.09
Withstand voltage

Type

Rated
(kV)
voltage (kV) Power-frequency/
Impulse

Rated
breaking
current(kA)

19/60

HVF

2,000

HVF154

HVF144

40

HVF146

50

HVF147

HVF354

HVF344

HVF346

HVF336

31.5

HVF705

40

HVF706

25
15

36/95
40

38

80/150

Rated current (A)1)


1,200

25
4.76

Model1)

1) Model number in the square "" shall be listed as below for the rated current according to applied standard.
- ANSI standard: 2 1,200A 4 2,000A 6 2,500A 7 3,000A 8 4,000A

2,500

3,000

23

4,000

HHIS-WC-LE-A39-14, 2012.1 Designed by JC Communication

www.hyundai-elec.com

Head Office

1000, Bangeojinsunhwan-doro Dong-gu, Ulsan, Korea


Tel: 82-52-202-8101~8
Fax: 82-52-202-8100

Seoul
(Sales & Marketing)

75, Yulgok-ro, Jongno-gu, Seoul, Korea


Tel: 82-2-746-8519, 7510

Atlanta

6100 Atlantic Blvd. Suite 201, Norcross, GA30097, U.S.A.


Tel: 1-678-823-7842
Fax: 1-678-823-7553

New Jersey

300 Sylvan Avenue, Englewood Cliffs, NJ, 07632, U.S.A.


Tel: 1-201-816-0286, 8028
Fax: 1-201-816-4083

London

2nd Floor, The Triangle, 5-17 Hammersmith Grove, London, W6 0LG, UK


Tel: 44-20-8741-0501
Fax: 44-20-8741-5620

Tokyo

8th Fl., Yurakucho Denki Bldg.1-7-1, Yuraku-Cho, Chiyoda-Ku, Tokyo, 100-0006, Japan
Tel: 81-3-3212-2076, 3215-7159
Fax: 81-3-3211-2093

Osaka

I-Room 5th Fl. Nagahori-Plaza Bldg. 2-4-8, Minami Senba, Chuo-Ku, Osaka, 542-0081, Japan
Tel: 81-6-6261-5766, 5767
Fax: 81-6-6261-5818

Riyadh

2nd Floor, The Plaza, P.O Box 21840, Riyadh 11485, Saudi Arabia
Tel: 966-1-462-2331
Fax: 966-1-464-4696

Dubai

205, Building 4, Emaar Square, Sheikh Zayed Road, Pobox 252458, Dubai, UAE
Tel: 971-4-425-7995
Fax: 971-4-425-7996

Kuwait

Floor 15, Al Sour Tower, Al Sour Street, Al-Qiblah, Kuwait


Tel: 965-2291-5354
Fax: 965-2291-5355

Moscow

World Trade Center, Ent. 3, #1902, Krasnopresnenskaya Nab. 12, Moscow, 123610, Russia
Tel: 7-495-258-1381
Fax: 7-495-258-1382

Madrid

Paseo De La Castellana 216, planta 0, 28046 Madrid, Spain


Tel: 34-91-732-0454, 733-6069
Fax: 34-91-733-2389

Sofia

1271, Sofia 41, Rojen Blvd., Bulgaria


Tel: 359-2-803-3200, 3220

Montgomery

201 Folmar Parkway, Montgomery, AL 36105, U.S.A.


Tel: 1-334-230-9921
Fax: 1-334-240-6869

Yangzhong

No.9 Xiandai Road, Xinba Scientific and Technologic Zone, Yangzhong, Jiangsu, P.R.C. Zip: 212212, China
Tel: 86-511-8842-0666, 0212
Fax: 86-511-8842-0668, 0231

Fax: 82-2-746-7441

Fax: 359-2-803-3203

You might also like