You are on page 1of 56

MultiLoad II

Single Meter Preset

Installation Guide
Version 1.2 - Part # 6067
December 19, 2008

EC Declaration Of Conformity the product listed below conforms to the relevant provisions of the following directives: 2004/108/EC The Electromagnetic Compatibility Directive (and its amending directives) 94/9/EEC The Potentially Explosive Atmospheres Directive (and its amending directives) Product: Process Controller with Operator Interface intended for use in potentially explosive atmospheres Model name/number: MultiLoad II SMP Protective Systems: Flameproof d, Intrinsic Safety ib Notified Body: Demko A/S Testing and Certification, Number 0539 P.O. Box 514 Lyskaer 8 DK-2730 Herlev, Denmark Conformity has been demonstrated with reference to the following documentation: EC type-examination certificate 06 ATEX 0619833X Compliance with the Essential Health and Safety Requirements has been assessed by reference to the following standards: EN 61000-6-4: 2007 Generic emissions for industrial operating environments EN 61000-6-2: 2005 Generic immunity for industrial operating environments EN 60079-0: 2006 Electrical apparatus for explosive gas atmospheresGeneral requirements EN 60079-1: 2004 Electrical apparatus for explosive gas atmospheres Flameproof enclosures d EN 50020: 2002 Electrical apparatus for potentially explosive atmospheresIntrinsic safety i

MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

ELECTRICAL CONSIDERATIONS AND REGULATORY REQUIREMENTS

! !

A battery is soldered to the CPU board and provides nonvolatile data storage and time/date retention. This battery should last between ten and thirteen years and is a factory replaceable part. This battery must be replaced with Matsushita Electric, model BR2477A only. Use of another battery may present a risk of fire or explosion. CAUTION: Battery may explode if mistreated. DO NOT RECHARGE, DISASSEMBLE, OR DISPOSE OF IN FIRE.

CAUTION: Use supply wires suitable for 5C above surrounding ambient. This equipment is suitable for use in Class I, Division 1, Groups C and D locations, Ex Zone I Group IIB locations, OR non-hazardous locations. WARNING: EXPLOSION HAZARD. Do not disconnect equipment unless power has been removed or the area is known to be non-hazardous. WARNING: EXPLOSION HAZARD. The area must be known to be non-hazardous before servicing/replacing the unit and before installing. WARNING: TO REDUCE THE RISK OF IGNITION OF HAZARDOUS ATMOSPHERES, conduit runs must have a sealing fitting connected within 18 inches of the enclosure. WARNING: TO REDUCE THE RISK OF IGNITION OF HAZARDOUS ATMOSPHERES, disconnect from the supply circuit before opening enclosure. Keep tightly closed when circuits are live.


!

!
!

!
!

WARNING: Substitution of components may impair intrinsic safety.

! !

WARNING: Consult installation manual for required cable entry size and thread. WARNING: If there are unused holes, blanking elements satisfying the flameproof d method of protection must be used. Blanking elements must be removable with the aide of a tool, ATEX certified, suitable for Gas Group IIB and suitable for an ambient temperature range of -40 C to +60 C.

Underwriters Laboratories, Inc. (UL) has not tested the performance or reliability of the security or signaling aspects of this product. UL has only tested for fire, shock and/or casualty hazards as outlined in UL's UL508, UL1203, and UL 913 Standards for Safety. UL Certification does not cover the performance or reliability of the security or signaling aspects of this product. UL MAKES NO REPRESENTATIONS, WARRANTIES OR CERTIFICATIONS WHATSOEVER REGARDING THE PERFORMANCE OR RELIABILITY OF ANY SECURITY OR SIGNALING RELATED FUNCTIONS OF THIS PRODUCT.

MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

Copyright Notice
Copyright 2006 - 2008 Toptech Systems, Inc. The information contained in this document is proprietary and confidential. No part of this document may be copied, reproduced, or transmitted in any medium without the express written permission of Toptech Systems, Inc.

Disclaimer
Toptech Systems assumes no responsibility for damages resulting from installation or use of its products. Toptech Systems will not be liable for any claims of damage, lost data, or lost time as a result of using its products.

Toptech Systems, Inc.


logo is a registered trademark of Toptech Systems, Inc. TMS, TMS5, TMS6, RCU II Remote Control Unit, Toptech MultiLoad II, MultiLoad II -RCU, FCM Flow Control Module are trademarks of Toptech Systems, Inc. Copyright 2008 Toptech Systems, Inc. All Rights Reserved.

MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

Table of Contents
Electrical Considerations and Regulatory Requirements ............................................................................... 3 CHAPTER 1 General.......................................................................................................................................... 8 1.1 Product Specification MultiLoad II SMP:............................................................................................ 8 1.1.1 Local (stand-alone) Mode ...................................................................................................................... 8 1.1.2 Remote Processing Mode ..................................................................................................................... 9 1.2 Information Alerts:................................................................................................................................. 10 1.2.1 Typographical Conventions: ................................................................................................................ 10 1.2.2 Receiving and/or Returning Equipment:.............................................................................................. 10 1.3 Electrostatic Discharge (ESD) Protection:.......................................................................................... 11 CHAPTER 2 Installing the SMP...................................................................................................................... 12 2.1 Tools Required....................................................................................................................................... 12 2.1.1 Installation............................................................................................................................................ 12 2.1.2 Servicing and Repair ........................................................................................................................... 12 2.2 Mounting SMP Enclosure: .................................................................................................................... 12 2.2.1 Metal Plate or Rail: .............................................................................................................................. 12 2.2.2 Wood:................................................................................................................................................... 12 2.2.3 Concrete or Cinder Block:.................................................................................................................... 12 2.3 Recommended Wire Sizes And Torque For All Terminal Blocks ..................................................... 13 2.4 Electrical Supply Connections............................................................................................................. 14 2.4.1 AC Power:............................................................................................................................................ 14 2.4.2 DC Power (option): .............................................................................................................................. 17 2.4.3 Equipment Grounding:......................................................................................................................... 17 2.4.4 Cable Gland Entries:............................................................................................................................ 17 CHAPTER 3 Data Communications Interface............................................................................................... 18 3.1 Communications Protocol Selection and Connection: ..................................................................... 19 3.1.1 RS-422/485:......................................................................................................................................... 19 3.1.2 RS-232................................................................................................................................................. 19 3.1.3 Host/TMS Communications (COM 1 - RS-485 4-wire)........................................................................ 20 3.1.4 Host/TMS Communications (COM 1 - RS-485 2-wire)........................................................................ 21 3.1.5 Host/TMS Communications (COM 1 - RS-232)................................................................................... 22 3.1.6 Host Ticket Printer/Data Logger (COM 2 - RS-232) ............................................................................ 23 3.1.7 Ethernet ............................................................................................................................................... 24 CHAPTER 4 I/O Configuration ....................................................................................................................... 25 4.1 Connecting Field Devices to the I/O Board......................................................................................... 25 4.1.1 TB2A +12 Vdc Supply ......................................................................................................................... 27 4.1.2 TB2B DC Inputs................................................................................................................................... 28 4.1.3 TB3 DC Outputs .................................................................................................................................. 30 4.1.4 TB4 RTD Input..................................................................................................................................... 31 4.1.5 TB1 AC Outputs................................................................................................................................... 32 4.1.6 TB5-Analog Input................................................................................................................................. 33 4.1.7 TB6-Analog Output .............................................................................................................................. 34 CHAPTER 5 Configuration ............................................................................................................................. 35 5.1 Navigating the System: ......................................................................................................................... 35 5.1.1 SMP Keypad:....................................................................................................................................... 35 5.1.2 Switch Access Control (Option) ........................................................................................................... 35 5.1.3 Type 1 Program / W&M switches ........................................................................................................ 36 5.1.4 Type 2 Program / W&M switches ........................................................................................................ 37

MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

5.1.5 Type 3 Program / W&M switches ........................................................................................................ 38 5.1.6 Program Mode / W&M DIP Switch ...................................................................................................... 39 5.1.7 Program Mode / W&M Field Switches................................................................................................. 40 5.1.8 Menus and Screens............................................................................................................................. 41 5.1.9 Field Modification and Data Entry........................................................................................................ 42 5.2 SMP Preliminary Configuration: .......................................................................................................... 44 5.3 Verify Communications Between SMP And I/O Board: ..................................................................... 46 CHAPTER 6 Service and Repair .................................................................................................................... 47 6.1.1 Modular Design:................................................................................................................................... 47 6.1.2 Operating the Flat Display Cable Connectors: .................................................................................... 48 6.1.3 CPU Subassembly Removal and Replacement: ................................................................................. 50 6.1.4 Display Subassembly Removal and Replacement:............................................................................. 51 6.1.5 Keypad Removal and Replacement: ................................................................................................... 51 6.1.6 Keypad Barrier Circuit Removal and Replacement:............................................................................ 51 CHAPTER 7 Appendix..................................................................................................................................... 52

Table of Figures
Figure 2.1 Figure 2.2 Figure 2.3 Figure 2.4 Figure 2.5 Figure 2.6 Figure 3.1 Figure 3.2 Figure 3.3 Figure 3.4 Figure 3.5 Figure 3.6 Figure 3.7 Figure 3.8 Figure 3.9 Figure 4.1 Figure 4.2 Figure 4.3 Figure 4.4 Figure 4.5 Figure 4.6 Figure 4.7 Figure 4.8 Figure 4.9 Figure 4.10 MultiLoad II Terminal Block Recommended Wire Size and Screw Torque..................................... 13 MultiLoad II AC Power Supply/Comm Board................................................................................... 15 AC Supply Terminal Block Access .................................................................................................. 16 Removal of AC Wiring Side Partition............................................................................................... 16 Replacement of AC Wiring Side Partition........................................................................................ 16 DC Power Connections ................................................................................................................... 17 RS485 4-Wire, Host to a Single MultiLoad II (recommended) ........................................................ 20 RS485 4-Wire, Host to Multiple MultiLoad IIs.................................................................................. 20 RS485 2-Wire, Host to a Single MultiLoad II ................................................................................... 21 RS485 4-Wire, Host to Multiple MultiLoad IIs.................................................................................. 21 RS232, Host to a Single MultiLoad II............................................................................................... 22 RS232, Host to Multiple MultiLoad IIs ............................................................................................. 22 Ticket Printer / Data Logger Connections with Handshake............................................................. 23 Ticket Printer / Data Logger Connections without Handshake........................................................ 23 Ethernet Connections ...................................................................................................................... 24 Connections to I/O Board ................................................................................................................ 26 TB2A + 12 Vdc Supply Assignments............................................................................................... 27 +12 Vdc Supply Voltage .................................................................................................................. 27 TB2B DC Input Assignments ........................................................................................................... 28 DC Inputs ......................................................................................................................................... 28 Product Meter and Permissive......................................................................................................... 29 Additive Meter.................................................................................................................................. 29 TB3 DC Outputs Assignments......................................................................................................... 30 DC Outputs ...................................................................................................................................... 30 TB4 RTD Input Assignments ........................................................................................................... 31

MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

Figure 4.11 Figure 4.12 Figure 4.13 Figure 4.14 Figure 4.15 Figure 4.16 Figure 4.17 Figure 4.18 Figure 5.1 Figure 5.2 Figure 5.3 Figure 5.4 Figure 5-5 Figure 6.1 Figure 6.2 Figure 6.3 Figure 7.1 Figure 7.2 Figure 7.3 Figure 7.4 Figure 7.5 Figure 7.6 Figure 7.7 Figure 7.8 Figure 7.9

RTD Connection .............................................................................................................................. 31 TB1 AC Output Assignments........................................................................................................... 32 Digital Control Valve and Additive Connections .............................................................................. 32 TB6 Analog Current Input Assignments .......................................................................................... 33 Analog Current Input........................................................................................................................ 33 TB6 Analog Output Assignments .................................................................................................... 34 Analog Current Output..................................................................................................................... 34 Analog Voltage Output..................................................................................................................... 34 Type 1 Program / W&M Switches.................................................................................................... 36 Type 2 Program / W&M Switches.................................................................................................... 37 Type 3 Program / W&M Switches.................................................................................................... 38 CPU Board Program and W&M DIP Switches ................................................................................ 39 Program and Weights and Measures Switch .................................................................................. 40 Cam lock in the Open (Up) position................................................................................................. 48 Display Cable Insertion.................................................................................................................... 49 Cam lock in the closed (down) position ........................................................................................... 49 Unit Outline Drawing Front View .................................................................................................. 52 Unit Outline Drawing Bottom View ............................................................................................... 52 Unit Outline Drawing Side View.................................................................................................... 53 Replacement Parts SMP Base Drawing.......................................................................................... 53 Exploded view front panel assembly ............................................................................................... 54 Microprocessor Board...................................................................................................................... 54 Power Supply Board ........................................................................................................................ 55 I/O Board.......................................................................................................................................... 55 Power Supply / Comm Board & I/O Board Chassis ........................................................................ 56

MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

Chapter 1 General

CHAPTER 1
1.1

GENERAL

PRODUCT SPECIFICATION MULTILOAD II SMP:

The MultiLoad II SMP (SMP) is designed to manage one arm, straight product loading. The system can operate in conjunction with the Toptech TMS system (remote processing mode) or in Local (stand alone) Mode. The SMP supports: Single meter/single product loading Two additive injectors Digital or analog control valves RTD input 4-20 mA input for either density or pressure Ethernet communications

1.1.1

LOCAL (STAND-ALONE) MODE

Product and access information are stored in non-volatile memory. The SMP prompts the driver for a driver number and Personal Identification Number (PIN). The PIN must match the driver PIN stored in the SMP database. After the PIN has been verified the SMP contains up to four configurable prompts that can be presented to the driver. After recording the data entry prompts, a load will be authorized.

Capabilities include: 300 driver/access IDs and associated PINs. 200 transaction archives complete with salable product, component detail and additive detail. 4 user-configuration custom prompts; resultant data stored with each transaction. 33 product recipes. Meter ticket combined ticket for all transaction listings in user configurable format. Meter, additive, pressure, density and temperature calibration features. Log of the last 1000 Weights and Measures parameter changes.

MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

Chapter 1 General

1.1.2

REMOTE PROCESSING MODE

Product and access control comes from TMS or remote computer systems. The number of driver records, customer prompts and recipes is virtually unlimited.

For product outline and dimensions see Appendix Figures 6.1 to 6.3.

Operating voltage: 85 - 250 Vac, 47-63 Hz, 300 150 mA OR 18 - 36 Vdc, 600mA Operating temperature (without heater): (with heater): Explosion proof enclosure: Type 4, IP65 UL Listed, Class 1, Division 1, Groups C & D ATEX Certified Group IIB, T4, Category 2G -22F to 140F (-25C to 60C). -40F to 140F (-40C to 60C).

Weight: 26 lbs (12 kg) Display: Color 4 Diagonal, QVGA Communications: 3 serial ports (1 RS-232, 1 RS-485, 1 User Selectable RS-232 or RS-485) 1 Ethernet port 10/100 MBPS

I/O Board provides following: 13 Digital I/O 5 AC Outputs 5 DC Inputs (3 high speed counters) 3 DC Outputs (1 Pulse output) 2 Analog Inputs 1 Analog Output Electrical Range 12 250Vac, 47 63Hz, 500mA per point 5 30Vdc 0 30Vdc, 600mA per point 1 4-wire 100 Ohm RTD, 1 4-20mA 1 4-20mA

Options: 24 Vdc Power Supply Program/Weights & Measures Switch

MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

Chapter 1 General

10

1.2

INFORMATION ALERTS:

Important information to enhance understanding and make better use of the product.

Indicates potential damage to hardware or loss of data.

!
1.2.1

Potential for property damage or that personal injury may occur. Pay close attention and follow instructions when you see this symbol.

TYPOGRAPHICAL CONVENTIONS: Boldface: Italics: Indicates what you are to press on the keypad. Example: Key in 00000. Emphasizes a key product or industry term. Example: the display features a pick list style of item selection.

1.2.2

RECEIVING AND/OR RETURNING EQUIPMENT:

The SMP should be immediately inspected after opening the packaging case. If any damage is visible notify the carrier at once to establish liability. Contact Toptech Account Management to initiate timely repair or replacement of the unit. Parts requiring repair or replacement can be identified from Appendix Figures 6.4 6.8. Account Management will issue a Return Materials Authorization (RMA) to return the product or parts requiring repair. Do not return any material to Toptech without an RMA. Account Management contact information: Account Management Toptech Systems 280 Hunt Park Cove Longwood, FL (407) 332-1774 Prior to installation the SMP should be stored in its packing case and be protected from damage due to handling and adverse weather conditions.

MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

Chapter 1 General

11

1.3

ELECTROSTATIC DISCHARGE (ESD) PROTECTION:

The SMP contains electronic components and assemblies subject to damage by ESD. The SMP was designed to protect against ESD while the unit is closed and in normal operation. Proper handling procedures must be observed during the removal, installation, repair and other handling of printed circuit board assemblies, electronic devices and components to include:

1) 2)

Service to be performed by authorized personnel only. The person performing the service must be grounded by an ESD grounding strap and connected to ground. While performing maintenance or repair, touch an unpainted metal of the SMP surface prior to touching or handling any printed circuit boards or electronic components. Printed circuit board assemblies must be placed in and transported in conductive bags or other conductive containers. Printed circuit boards must not be removed from the conductive container until time of use. All other best practices for protecting devices from ESD must be observed.

3)

4)

5) 6)

MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

Chapter 2 Installing the MultiLoad II Div2

12

CHAPTER 2
2.1
2.1.1 2.1.2 -

INSTALLING THE SMP

TOOLS REQUIRED
INSTALLATION 6 mm hex wrench required for tightening cover bolts SERVICING AND REPAIR #4 Philips screwdriver for circuit board removal socket wrench for CPU circuit board removal, 5/16 socket wrench for display board removal Torx T15 for removal of keypad bezel security screws

2.2

MOUNTING SMP ENCLOSURE:

The SMP enclosure should be located in a shaded area. Direct sunlight can increase internal temperature to greater than 140 F or 60 C. Exterior dimensions of the enclosure are shown in Appendix Figures 6.1 through 6.3. Cable entries (5) M20x 1.5 mm are located at the bottom of the enclosure. The enclosure cover is secured by (12) 8 mm hex cap screws. When the screws are loosened, the front cover will swing left and hang from its hinges. A 6mm Allen head wrench is required to remove the screws. Fasteners must be selected to support the weight of the enclosure (26 lbs or 12 kg). Mounting suggestions include:

2.2.1

METAL PLATE OR RAIL:

Four hex head 5/16 OD (M8) bolts with a 5/16 flat washer, OD (M8, 18mm OD) under the head of the bolt. Fasten with four 5/16 (M8) hex nuts.

2.2.2

WOOD:

Same as metal plate above or Four hex head 2 X 5/16 OD (M8 x 50 mm) lag bolts with a 5/16 flat washer, OD (M8, 18 mm OD) under the head of the bolt.

2.2.3

CONCRETE OR CINDER BLOCK:

Four x 2 1/4 Tapcon, 5/8 diameter hex flange head masonry fasteners with a flat washer, OD under the head of the screw. Pre-drill for Tapcons using a 3/16 masonry drill bit.

MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

Chapter 2 Installing the MultiLoad II Div2

13

2.3

RECOMMENDED WIRE SIZES AND TORQUE FOR ALL TERMINAL BLOCKS

Three sizes of terminal blocks are used in the MultiLoad II products: 7.62 mm pitch (supply power), 5.08 mm pitch (line voltage switching), and 3.81 mm pitch (serial communication, analog or dc voltages). All sizes, orientations, and manufacturer brands have different torque and wire size specifications. Please follow the recommendations in Figure 2.1 below. The manufacturer may be determined by looking for the logo molded into the terminal block, usually on the side.

Manufacturer

Logo

Phoenix On-Shore Technology Sauro

Terminal Orienta- Allowable Wire Size Block Pitch tion [mm] [AWG] 7.62 Straight 30 - 12 7.62 7.62 Straight Straight 24 - 12 30 - 12

Recommended Screw Torque [Nm] [LB in] .6 - .8 5-7 0.40 0.8 3.5 7

Location

TB1, Power Supply Board

Phoenix On-Shore Technology Sauro

5.08 5.08 5.08

Straight Straight Straight

30 - 12 24 - 12 30 - 12

.6 - .8 0.40 0.8

5-7 3.5 7

TB1, I/O Board

Phoenix On-Shore Technology Phoenix On-Shore Technology Sauro

3.81 3.81

Straight Straight

30 - 14 28 - 16

0.5 0.19

4 1.7

TB2 - TB5, Power Supply Board; TB3 TB6, I/O Board

3.81 3.81 3.81

90 90 90

30 - 14 26 - 16 30 - 14

0.2 - 0.5 0.3 0.31

2-4 3 2.7

TB2A, TB2B, I/O Board

Figure 2.1

MultiLoad II Terminal Block Recommended Wire Size and Screw Torque

MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

Chapter 2 Installing the MultiLoad II Div2

14

2.4

ELECTRICAL SUPPLY CONNECTIONS

The SMP may be equipped for either 85 -250Vac or 24Vdc operation. Verify the power type before making any connections. To reduce the risk of ignition in hazardous atmospheres, conduit runs must have seals Installed within 18 inches (45 cm) of the enclosure. UL requires that field wiring is rated 75C or greater.

! ! !

Canada requires that supply wires are rated at least 5C above surrounding ambient.

Do not route AC and DC wiring in the same conduit. All wiring must enter the MultiLoad II enclosure through conduit via entries in the bottom of the enclosure. All conduits must be terminated at the enclosure by use of appropriately rated conduit hubs or glands. Wires must be stripped and fully inserted into terminal block with no bare conductor exposed. The terminal blocks are designed to accept wires sizes 12 AWG (3.31 mm2) through 24 AWG (0.205 mm2). The recommended tightening torque is 0.5 Nm [4.4 inch-pound force] to 0.6 Nm [5.3 inch pound-force]. Both ac and dc input models require a safety ground connection as described in section 2.3.3 below. A service loop is recommended for all wires and cables entering the enclosure. Do not allow service loop cables to overlap the circuit boards. Coil any cable length in the bottom of the enclosure. Keep AC wiring separated from all other wiring in the enclosure by use of the supplied partitions (see wire partition instructions below).

Wiring must comply with all local electrical codes.

2.4.1

AC POWER:

Provide over current protection using a 15 Amp circuit breaker or equivalent. The breaker also serves as a means of disconnection from the operating supply as required by UL/ISA/IEC 61010-1 and CAN/CSA-C22.2 NO. 610101. The disconnect device may not be blocked or be made difficult to operate by the MultiLoad II or any other device. Note that installation of disconnects are typically prohibited in Class I, Division 2 locations. Power required: 85 250 Vac, 47 63 Hz, 300 mA @ 85Vac/ 150 mA @250Vac. The power connector is located in the right hand corner of the Power Supply/Communication board as shown in figure 2.1. Select supply wire rated 300V or better with a flammability rating of at least VW-1.

MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

Chapter 2 Installing the MultiLoad II Div2

15

Figure 2.2

MultiLoad II AC Power Supply/Comm Board

MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

Chapter 2 Installing the MultiLoad II Div2

16

A plastic flap has been installed over TB1 and along the right edge of the enclosure. All services loops or excess AC wiring should be placed under the partition. This includes AC wiring attached to TB1 of the optional I/O board. The figures below illustrate how to gain access to the terminal blocks, and replace the partitions so that wires containing Hazardous voltages are separated from all low voltage circuits (including field wired circuits). .

Figure 2.3

AC Supply Terminal Block Access

Figure 2.4

Removal of AC Wiring Side Partition

Figure 2.5

Replacement of AC Wiring Side Partition

MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

17

2.4.2

DC POWER (OPTION):

The MultiLoad II is optionally available with a 24 Vdc power supply. The supply should be protected by a 1.5 Amp fuse. Power required: 18 36 Vdc, 600mA. The 3 position terminal block is located in the right hand corner of the power supply/communication board.

Wiring guidelines for using 24 Vdc power supply: Wire gauge (AWG) 24 22 20 18 Figure 2.6 DC Power Connections 16 Distance (feet) 50 100 150 250 400

2.4.3

EQUIPMENT GROUNDING:

A safety ground should be attached to terminal block TB1 (on both ac and dc input power models) to maintain electrical safety in the event of a fault condition. Follow the terminal block wiring instructions in section 2.3. Note that the external ground connection is not provided for the attachment of the protective conductor (the safety ground). Rather, it is provided only as a supplemental bonding connection where local authorities permit or require such a connection, for example, as a means of equipotentiality. The wire connection is on the bottom right exterior surface. The following wire sizes may be used: 10 AWG (5.26 mm2) or 11 AWG (4.17 mm2).

!
2.4.4

Do not connect the power supply dc common to earth ground.

CABLE GLAND ENTRIES:

Five M20 x 1.5 mm apertures in the enclosure bottom are provided for the installation of cable glands. A gland with the correct corresponding thread must be installed in the opening.

WARNING: If there are unused holes, blanking elements satisfying the flameproof d method of protection must be used. Blanking elements must be removable with the aide of a tool, ATEX certified, suitable for Gas Group IIB and suitable for an ambient temperature range of -40 C to +60 C.

Chapter 3 Data Communications Interface

18

CHAPTER 3

DATA COMMUNICATIONS INTERFACE

The MultiLoad II has four communications ports (see figure 2.1) each with a specific purpose. The following section provides the information required to select and make the wiring connections to the ports.

Communication Port

Interface Type

Typical Function

Terminal (Figure 2.1)

Comm. Port 0

RS-485

Internal I/O board / FCM I / FCM II / PCM Communication Host Communication (TMS) Ticket Printer/Data Logger Host Communication (TMS)

TB2

Comm. Port 1

RS-232 or RS-485

TB3 RS-232 TB4 RS-485 TB5

Comm. Port 2

RS-232

Ethernet

10/100MBPS

J3 Internal Cat 5 Cable

If service loop is used, maximum wire length in service loop not to exceed 3 inches.. Separate AC and DC wiring by at least 3 inches. Do not allow excess wire in service loop to overhang printed circuit board.

MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

Chapter 3 Data Communications Interface

19

3.1
3.1.1

COMMUNICATIONS PROTOCOL SELECTION AND CONNECTION:


RS-422/485:

RS-422/485 communications protocol is designed for multi-point (i.e. computer to multiple devices, also called multi-dropped) communications up to 4,000 feet (1,220 Meters). RS-422 requires 4-wires (2 twisted pair) for full duplex communications and utilizes a transmit pair of wires (TDA & TDB) and a receive pair of wires (RDA & RDB). RS-485 requires 2-wires (1 twisted pair) for half duplex communications and utilizes a single pair of wires (TDA/RDA & TDB/RDB) for transmit and receive. This manual will typically refer to both RS-422 and RS-485 as simply RS485 2 wire or RS485 4 wire. A ground wire is not required, though some devices may have a terminal block for a ground. Wire used must meet the following: 24 AWG stranded. 4-wire, two twisted pair with overall shield. 2-wire, one twisted pair with overall shield. 30 pF maximum between conductors. 1,000 ohm impedance. Maximum length: 4,000 feet (1,220 Meters) Maximum stub length: 15 feet. All exposed shields must be properly insulated to prevent short circuits. All shields must be continuous, soldered and properly insulated.

3.1.2

RS-232

RS-232 protocol is designed for point-to-point (i.e., computer to a single device) communications limited to 50 feet requiring a minimum of 3 wires transmit, receive and ground. Additional wires are required for hardware handshaking when using printers and data loggers. Wire used must meet the following: 24 AWG. 3 conductor with overall shield (data only) or 8 conductor with overall shield (full handshaking). 30 pF maximum between conductors.

MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

Chapter 3 Data Communications Interface

20

3.1.3

HOST/TMS COMMUNICATIONS (COM 1 - RS-485 4-WIRE)

The Host/TMS Computer System can be connected to the MultiLoad II via RS485 4-wire on COM 1. The TD and RD pairs are swapped at the Host/TMS.

Host/TMS RS485 TDA TDB RDA RDB

MultiLoad II COM 1 RDA RDB TDA TDB

Figure 3.1

RS485 4-Wire, Host to a Single MultiLoad II (recommended)

Host/TMS RS485 TDA TDB RDA RDB

MultiLoad II #1 COM 1 RDA RDB TDA TDB

MultiLoad II #n COM 1 RDA RDB TDA TDB

Figure 3.2

RS485 4-Wire, Host to Multiple MultiLoad IIs

MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

Chapter 3 Data Communications Interface

21

3.1.4

HOST/TMS COMMUNICATIONS (COM 1 - RS-485 2-WIRE)

The Host/TMS Computer System can be connected to the MultiLoad II via RS485 2-wire on COM 1. The TD and RD pairs tied together at the Host/TMS and all MultiLoad IIs.

Host/TMS RS485 TDA TDB RDA RDB

MultiLoad II COM 1 RDA RDB TDA TDB

Figure 3.3

RS485 2-Wire, Host to a Single MultiLoad II

Host/TMS RS485 TDA TDB RDA RDB

MultiLoad II #1 COM 1 RDA RDB TDA TDB

MultiLoad II #n COM 1 RDA RDB TDA TDB

Figure 3.4

RS485 4-Wire, Host to Multiple MultiLoad IIs

MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

Chapter 3 Data Communications Interface

22

3.1.5

HOST/TMS COMMUNICATIONS (COM 1 - RS-232)

The Host/TMS Computer System can be connected to the MultiLoad II via RS232 on COM 1. The TX and RX are swapped at the Host/TMS. MultiLoad II has the ability to multi-drop onto a RS232 line.

Host/TMS RS232 TX RX GND

MultiLoad II COM 1 RX TX GND

Figure 3.5

RS232, Host to a Single MultiLoad II

Host/TMS RS232 TX RX GND

MultiLoad II #1 COM 1 RX TX GND

MultiLoad II #n COM 1 RX TX GND

Figure 3.6

RS232, Host to Multiple MultiLoad IIs

MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

Chapter 3 Data Communications Interface

23

3.1.6

HOST TICKET PRINTER/DATA LOGGER (COM 2 - RS-232)

A Ticket Printer or Data Logger can be connected to the MultiLoad II via RS232 on COM 2. The TX and RX are swapped at the MultiLoad II. Handshake lines MUST be connected or terminated or a Printer Error will be reported. MultiLoad II will monitor CTS, DSR and DCD for active signals.

MultiLoad II COM 2 RX CTS TX GND DSR DCD RTS DTR


Figure 3.7

Printer Logger RS232 DB25 Connector 2 - TX 20 - DTR 3 - RX 7 GND 4 RTS 5 CTS 6 DSR 8 - DCD

Ticket Printer / Data Logger Connections with Handshake

MultiLoad II COM 2 RX CTS TX GND DSR DCD RTS DTR


Figure 3.8

Printer Logger RS232 DB25 Connector 2 - TX 20 - DTR 3 - RX 7 GND 4 RTS 5 CTS 6 DSR 8 - DCD

Ticket Printer / Data Logger Connections without Handshake

MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

Chapter 3 Data Communications Interface

24

3.1.7

ETHERNET

Ethernet wiring standard T568B - Cat5 cable (or greater).

Figure 3.10 illustrates the required connections for Ethernet.

Twisted Pairs
1 White/org 2 Org 3 White/Grn 1 2 3

4 Blue 5 White/Blue

4 5

6 Green 7 White/Brown 8 Brown

6 7 8

Figure 3.9

Ethernet Connections

MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

Chapter 4 I/O Configuration

25

CHAPTER 4

I/O CONFIGURATION

4.1

CONNECTING FIELD DEVICES TO THE I/O BOARD

The I/O board is mounted above the Power Supply/Comm board. The I/O board is connected to the Power Supply/Comm board at J4 & J5. Corresponding connections are on bottom side of the I/O board.

Do not open enclosure unless power has been removed.

The following further defines Inputs and Outputs supported by the I/O board:

5 AC Outputs: 3 DC Outputs: 5 DC Inputs:

12 - 250 Vac rms, 500 mA (Per Point), TB1 0 - 30 Vdc, 600 mA (Per Point), TB3 5 - 30Vdc, TB2B Dual Channel flow meter inputs (1-5000Hz) 3 inputs for miscellaneous signals

12Vdc Output:

TB2A 2W isolated Power Supply Power for flow meter pulsers or preamps

RTD Input:

TB4 100-ohm platinum, four wire Coefficient 0.00385 Ohm/Ohm/degrees C

Analog Input Analog Output

TB5 TB6

MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

Chapter 4 I/O Configuration

26

Figure 4.1

Connections to I/O Board

MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

Chapter 4 I/O Configuration

27

4.1.1

TB2A +12 VDC SUPPLY

Terminal Block (TB2A) provides a connection point to the MultiLoad II 2W 12V isolated power supply. Use the supply to power flow meter pulse transmitters or pre-amplifiers. This source can also be used as a switching voltage to the MultiLoad II DC Inputs at TB2B, DC Outputs at TB3, and voltage source for the analog output.

Terminal Block (TB2A) TB2A-1 through TB2A-5 TB2A-6 through TB2A-10 Figure 4.2

Function +12 Vdc DC common

TB2A + 12 Vdc Supply Assignments

TB2a-1 TB2a-2 TB2a-3 +12 Vdc TB2a-4 Power TB2a-5 Supply TB2a-6 TB2a-7 DC TB2a-8 common TB2a-9 TB2a-10 TB2a +12 Vdc
Figure 4.3 +12 Vdc Supply Voltage

+12 Vdc

Meter Pre-Amp or Pulser

MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

Chapter 4 I/O Configuration

28

4.1.2

TB2B DC INPUTS

Port Port 4

Terminal Block (TB2b) TB2B-1 TB2B-2

Function DC Input or Pulser V+ DC Input or Pulser GND DC Input or Pulser V+ DC Input or Pulser GND DC Input or Pulser V+ DC Input or Pulser GND DC Input or Pulser V+ DC Input or Pulser GND DC Input or Pulser V+ DC Input or Pulser GND TB2B DC Input Assignments 5-30 Vdc dual channel flow meter inputs 15,000 Hz

Port 5

TB2B-3 TB2B-4

Port 6

TB2B-5 TB2B-6

Port 7

TB2B-7 TB2B-8

Port 9

TB2B-9 TB2B-10 Figure 4.4

TB2b-1 TB2b-2 TB2b-3 TB2b-4 TB2b-5 TB2b-6 TB2b-7 TB2b-8 TB2b-9 TB2b-10 TB2b DC Inputs
Figure 4.5

Port 4 Port 5 Port 6 Port 7 Port 9

DC Inputs

MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

Chapter 4 I/O Configuration

29

The source voltage for the DC inputs to MultiLoad II can come from TB2a (+12 Vdc) or from an external source, not to exceed 30 Vdc.

TB 2a- 1 TB 2a- 2 TB 2a- 3 +12 Vdc TB 2a- 4 TB 2a- 5 TB 2a- 6 TB 2a- 7 DC TB 2a- 8 common TB 2a- 9 TB2a-10 TB2a +12 Vdc Figure 4.6 Product Meter and Permissive TB2b DC Inputs Permissive Meter Pre -Amp or Pulser
+12 Vdc

TB2b-1 A B TB2b -2 TB2 b-3 TB2 b-4 TB2 b-5 TB2 b-6 TB2b -7 TB2b -8 TB2b -9 TB2 b-10

TB2a-1 TB2a-2 TB2a-3 +12 vdc TB2a-4 TB2a-5 TB2a-6 TB2a-7 DC dc common TB2a-8 commom TB2a-9 TB2a-10 TB2a +12 vdc

TB2b-1 TB2b-2 TB2b-3 TB2b-4 TB2b-5 TB2b-6 TB2b-7 TB2b-8 TB2b-9 TB2b-10 Additive Meter Pre-Amp
Figure 4.7 Additive Meter

+12 vdc

TB2b DC Inputs

MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

Chapter 4 I/O Configuration

30

4.1.3

TB3 DC OUTPUTS

The source voltage for the DC Outputs to field devices can come from TB2a (+12 Vdc) or from an external source, not to exceed 30 Vdc, 1.2A Port Port 10 Terminal Block (TB) TB3-1 TB3-2 Port 11 TB3-3 TB3-4 Port 12 TB3-5 TB3-6 Figure 4.8 Function V+ In V+ Out V+ In V+ Out V+ In V+ Out TB3 DC Outputs Assignments 0-30 Vdc 1,2A

TB2a-1 TB2a-2 TB2a-3 +12 Vdc TB2a-4 TB2a-5 TB2a-6 TB2a-7 DC TB2a-8 common TB2a-9 TB2a-10 TB2a +12 Vdc

TB3-1 TB3-2 TB3-3 TB3-4 TB3-5 TB3-6

Pump Relay Coil

TB3 DC Outputs

Figure 4.9

DC Outputs

MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

Chapter 4 I/O Configuration

31

4.1.4

TB4 RTD INPUT

Wire a 100 ohm, four-wire, platinum RTD to TB4 as shown. The RTD must have a coefficient of 0.00385 Ohm / Ohm / C.

Terminal Block (TB) TB4-1 TB4-2 TB4-3 TB4-4 Figure 4.10

Function V+ R+ RGND TB4 RTD Input Assignments

TB4-1 TB4-2 TB4-3 TB4-4 TB4 RTD Input


Figure 4.11

White V+ White R+ Red RRed GND

Four-Wire RTD Platinum, 100 Ohm

RTD Connection

MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

Chapter 4 I/O Configuration

32

4.1.5

TB1 AC OUTPUTS

Connect the 12-250 VAC to the even numbered terminals. Limit current to 1.25 A (rms).

Port Port 0

Terminal Block (TB1) TB1-10 TB1-9

Function Line In Line Out Line In Line Out Line In Line Out Line In Line Out Line In Line Out TB1 AC Output Assignments
L1 12- 250 VAC

Port 1

TB1-8 TB1-7

Port 2

TB1-6 TB1-5

12-250 Vac 1.,25A

Port 3

TB1-4 TB1-3

Port 8

TB1-2 TB1-1 Figure 4.12

Port 0 Port 1 Port 2 Port 3 Port 8

TB1-10 TB1-9 TB1-8 TB1-7 TB1-6 TB1-5 TB1-4 TB1-3 TB1-2 TB1-1 TB1 AC Outputs

N
Add. Inject Solenoid Add. Inject Solenoid N.O. Solenoid N.C. Solenoid

Figure 4.13

Digital Control Valve and Additive Connections

MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

Chapter 4 I/O Configuration

33

4.1.6

TB5-ANALOG INPUT

Terminal Block (TB5) TB5-1 TB5-2 Figure 4.14

Function I+ Positive (higher) voltage or current I- Negative (lower) voltage or current TB6 Analog Current Input Assignments

Analog current input from an analog device to TB5.

TB5-1 TB5-2 TB5 Analog Input

I++ GND Analog Current Transmitter

Figure 4.15

Analog Current Input

MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

Chapter 4 I/O Configuration

34

4.1.7

TB6-ANALOG OUTPUT

Terminal Block (TB) TB6-1 TB6-2 TB6-3 TB6-4 Figure 4.16

Function V+ (Power) GND I Input (Current) V Input (Voltage) TB6 Analog Output Assignments

Analog current output from TB6 to an analog device.

TB2A-5 TB2A-6 TB6-1 TB6-2 TB6-3 TB6-4 TB6 Analog Output


Figure 4.17 Analog voltage output from TB6 to an analog device. Analog Current Output

GND I In Analog Current Receiver

TB2A-5 TB2A-6 TB6-1 TB6-2 TB6-3 TB6-4 TB6 Analog Output


Figure 4.18 Analog Voltage Output

GND V In Analog Voltage Receiver

MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

Chapter 6 Service and Repair

35

CHAPTER 5
5.1

CONFIGURATION

NAVIGATING THE SYSTEM:

The following describes how to navigate the system, select field values, perform data entry, and toggle options on and off. 5.1.1 SMP KEYPAD:

The SMP keypad has 18 keys, including numeric and function keys, used to:

Select menu items and fields Enter data in fields Initiate actions Return to previous screens

Numeric keys (1 through 9 and 0) used to enter numeric data. The decimal point (. ) is used to enter numeric field data with a decimal point. CLR key is used to clear data entered in error. The CLR key is a backspace key erasing characters as the cursor moves backward.

5.1.2

SWITCH ACCESS CONTROL (OPTION)

MultiLoad II supports external access control switches. These switches limit access to Program Mode and changes to Weights and Measures controlled parameters. There are three types of external switches and all can be sealed and/or locked to prevent access to Program Mode and prevent changes to Weights and Measures controlled parameters.

In Program Mode the operator has access to the following: The Configuration Menu parameters The Diagnostics Menu and its functions Other administrative procedures, such as clearing high-level alarms.

To access Program Mode, the MultiLoad II terminal operator must: 1. Move the Program Mode switch into the active position. 2. At the idle card in screen, enter the security code (default security code is 000000) and press the <Next> key.

Your local Weights and Measures office may need to be contacted after breaking the seal and changing parameters. This is typically done only during meter proving or temperature calibration.

MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

Chapter 6 Service and Repair

36

5.1.3

TYPE 1 PROGRAM / W&M SWITCHES

Type 1 switches consist of two separate external rotary switches, one for Program Mode Access, and one for W&M change access. Each switch has external fold down cover that can be locked or sealed with a wire and lead seal to prevent moving the switch into the active state. Each cover will also be stamped as W&M or Program to indicate function.

Figure 5.1

Type 1 Program / W&M Switches

MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

Chapter 6 Service and Repair

37

5.1.4

TYPE 2 PROGRAM / W&M SWITCHES

Type 2 switches consist of a single 3-position external rotary switches, where each position corresponds to an operating mode. The switch has two external fold down covers that limits the switch rotation as described below. Each cover can be locked or sealed with a wire and lead seal to prevent moving the switch into the active states. Each cover will also be stamped as W&M or Program to indicate function.

Figure 5.2

Type 2 Program / W&M Switches

MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

Chapter 6 Service and Repair

38

5.1.5

TYPE 3 PROGRAM / W&M SWITCHES

Type 3 switches consist of two separate external magnetic bolts, one for Program Mode Access, and one for W&M change access. Program or W&M access is achieved by removing the corresponding bolt. Each bolt has a small hole that can be sealed with a wire and lead seal to detect unauthorized access. Both bolts are also have an external fold down cover that can be locked to prevent moving someone from removing either bolt. The cover will also be stamped as W&M or Program to indicate the function of each bolt.

Figure 5.3

Type 3 Program / W&M Switches

MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

Chapter 6 Service and Repair

39

5.1.6

PROGRAM MODE / W&M DIP SWITCH

Two DIP switches on the CPU board can also provide the closure of the Program Mode / W&M switch contacts. When the MultiLoad II does not have the external Program Mode / W&M switch installed, it is necessary to use this DIP switches on the CPU board to enable program mode and W&M access. Switches are numbered 1 through 4 with 1 being closest to the front of the enclosure (top of the picture), and 4 being toward the back of the enclosure (bottom of the picture). When switch is in the ON position, the switch is in the active state. A switch is ON when it moved right, and OFF when moved to the left. Switch #3 is the program mode switch. Switch #4 is the W&M access switch. In the Figure below, the Program Mode switch is currently Active, while the W&M Switch is not active.

A switch input will be considered active with either the DIP switch OR external switch is active (ON). Your Weights and Measures inspector may wish to verify that DIP switch 4 (bottom switch) is in the off position (moved left) prior to sealing the MultiLoad II enclosure to ensure that W&M parameters are secure.

Figure 5.4

CPU Board Program and W&M DIP Switches

MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

Chapter 6 Service and Repair

40

5.1.7

PROGRAM MODE / W&M FIELD SWITCHES

The MultiLoad II also has the ability to accept field inputs for the Program Mode and W&M Access switches. The W&M Key FCM# and Program Key FCM# in the RCU W&M Parameters list allow any field I/O position to be the source of the switch input. See Weights and Measures for more information.

If an external switch is wired to the MultiLoad II as a W&M access switch, the installer may be required to seal the switch enclosure and all conduit junction points between the switch and the MultiLoad II to ensure that the W&M parameters remain secure. Consult your local Weights and Measures for specifics. A switch input will be considered active with either the external switch OR a configured I/O point is active (ON). Your Weights and Measures inspector may wish to verify the W&M Key FCM# parameter prior to sealing the MultiLoad IIs W&M switch to ensure that W&M parameters are secure. If no external field W&M switch is installed, this parameter MUST be DISABLED. If an external field W&M switch is installed, this parameter MUST indicate the correct field I/O port.

Enter Program Mode -> Weights & Measures -> RCU RCU W&M SETUP MM/DD/YYYY Date: Measure Used: Min Time Change Secs: Measure on Load Scrn: W&M Key FCM#: Program Key FCM#:

ENABLED GALLONS 60 DISABLD DISABLD DISABLD

Next Operating Mode: Program Mode: Weights and Measures Mode:

Prev

Exit

Enter

Normal operation of the MultiLoad II. Switch can be locked or sealed in this position. Provides access to configuration parameters, diagnostic menu, administrative functions and clearing high-level alarms. Switch can be locked or sealed in this position. Provides access to weight and measures parameters. Proceed to Weights and Measures section of the menu. For operation in this mode see the Weights and Measures section of the manual. Switch can be locked or sealed out of this position. Figure 5-5 Program and Weights and Measures Switch

MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

Chapter 6 Service and Repair

41

5.1.8

MENUS AND SCREENS

The MultiLoad II SMP Main Menu is shown below. From this menu, you select one of four main functions.

M A I N M E N U Configuration Diagnostics Views and Inquiries Weights and Measures

Next

Prev

Exit

Enter

The reverse video highlight bar indicates the current selection. Press Next to select Diagnostics, and then press the Enter key to go to the Diagnostics Menu.

D I A G N O S T I C S M E N U Card Reader Meters COM Loopback Components Serial Ports Additives Network Test Custom Logic Keypad Display Unicode FCM Com PCM Com FCM Health PCM Health RCU Bay Preset Next Prev Exit Enter

For menu options and function screen items, pressing the Next key moves the selection bar down, and pressing the Prev (Previous) key moves the selection bar up. To return to the Main Menu, press EXIT. To return to any previous screen, press the EXIT key.

MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

Chapter 6 Service and Repair

42

5.1.9

FIELD MODIFICATION AND DATA ENTRY

MultiLoad II SMP will have all fields populated with default values. There are two types of fields, toggle or data entry. Toggle fields contain a number of choices. Scroll through the choices by pressing the Enter key. Data entry fields require that a value be entered into the field, within a given, applicable range. In the example below, RCU Address field is highlighted.

RCU GENERAL SETUP RCU Address: Remote Processing: Password #1: Password #2: Password #3: Password #4: Password #5: Modem Dial: Modem Login: RCUTE TOPTECH Terminal Name: Toptech Terminal

001 DISABLD ******* ******* ******* ******* *******

Next

Prev

Exit

Enter

Press ENTER to choose the field. A blinking cursor indicates data can be entered.

RCU GENERAL SETUP RCU Address: Remote Processing: Password #1: Password #2: Password #3: Password #4: Password #5: Modem Dial: Modem Login: RCUTE TOPTECH Terminal Name: Toptech Terminal

DISABLD ******* ******* ******* ******* *******

Enter

Exit

MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

Chapter 6 Service and Repair

43

Type in the new value (e.g. 123) and press ENTER. The new value displays on the screen.

RCU GENERAL SETUP RCU Address: Remote Processing: Password #1: Password #2: Password #3: Password #4: Password #5: Modem Dial: Modem Login: RCUTE TOPTECH Terminal Name: Toptech Terminal 123 DISABLD ******* ******* ******* ******* *******

Enter

Exit

Using this same screen as an example, the Remote Processing line is selected and ENTER is pressed, use the NEXT or PREV keys to toggle between the values ENABLED and DISABLD, as shown below. You must then press ENTER to accept the desired choice.

RCU GENERAL SETUP RCU Address: Remote Processing: Password #1: Password #2: Password #3: Password #4: Password #5: Modem Dial: Modem Login: RCUTE TOPTECH Terminal Name: Toptech Terminal

001 DISABLD ******* ******* ******* ******* *******

Next

Prev

Exit

Enter

MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

Chapter 6 Service and Repair

44

5.2

SMP PRELIMINARY CONFIGURATION:

1) Energize the SMP. 2) When the SMP is first energized the Cardin screen appears, indicating Operating Mode. For Access Press Next to Begin

3) Go to program mode by entering 00000 on the keypad, then press Next.

If SMP has Program/Weights and Measures switch, switch must be set to Program Mode. (See Appendix Figure 6.10) 00000 is the factory default access code. See RCU General setup section for changing or adding new access codes.

4) The program mode main menu displays: M A I N M E N U Configuration Diagnostics Views and Inquiries Weights and Measures

Next

Prev

Exit

Enter

5) Press Enter to access the Configuration menu.

MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

Chapter 6 Service and Repair

45

6) Press Enter to access RCU General Setup. C O N F I G U R A T I O N Communication Network RCU General Setup RCU Setup Equipment Setup Alarm Setup Products Additive Cal. Remote Adtv Cal. Access ID's Custom Logic Customer Logo Setup M E N U

Next

Prev

Exit

Enter

7) Press Enter and key in RCU address (001) of SMP. The default RCU address is 001. RCU GENERAL SETUP RCU Address: Remote Processing: Password #1: Password #2: Password #3: Password #4: Password #5: Modem Dial: Modem Login: RCUTE TOPTECH Terminal Name: Toptech Terminal

001 DISABLD ******* ******* ******* ******* *******

Next

Prev

Exit

Enter

8) Press Exit to return to the Configuration Menu. 9) Select and press Enter to return to the Main Menu. 10) If SMP has Program/Weights and Measures switch return switch to Operating Mode.

MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

Chapter 6 Service and Repair

46

5.3

VERIFY COMMUNICATIONS BETWEEN SMP AND I/O BOARD:

Enter program mode by pressing 00000 on the keypad, then press Next key. Select diagnostics from main menu. D I A G N O S T I C S M E N U Card Reader Meters COM Loopback Components Serial Ports Additives Network Test Custom Logic Keypad Display Unicode FCM Com PCM Com FCM Health PCM Health RCU Bay Preset Next Prev Exit Enter Select FCM COM 004 FCM COM DIAGNOSTICS 00-Ok

Exit If screen display is the same as above, the I/O board is communicating with the SMP. If I/O board is not communicating the message 00-ERR appears. If 00-ERR appears see I/O board diagnostics.

MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

Chapter 6 Service and Repair

47

CHAPTER 6
6.1.1

SERVICE AND REPAIR

MODULAR DESIGN:

The MultiLoad II SMP has been constructed with replaceable modules or sub-assemblies that are available from Toptech (see Appendix for part numbers). These include: CPU Subassembly (CPU Chassis, CPU Board, Power Supply / COM Board, I/O Board). Display Subassembly (Active Matrix Display and Display Board) Keypad Keypad Barrier Circuit

The following sections describe how to remove and replace each subassembly and where possible, how to further disassemble the subassembly

NOTE: Do not service MultiLoad II without removing mains power.

NOTE: Do not open the MultiLoad II enclosure while the MultiLoad II is energized.

MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

Chapter 6 Service and Repair

48

6.1.2

OPERATING THE FLAT DISPLAY CABLE CONNECTORS:

Removal: 1. To remove the Display Cable rotate the cam to the open (up) position. (See Figure 5.2.) 2. Gently pull the cable straight out free of the connector. Installation: 1. To install the display cable make sure the cam is in the open (up) position. 2. Gently insert the cable with the dark insulated side towards the cam. (See Figure 5.3.) When inserting the cable make sure that it is not tilted to one side or the other and that the bottom of the cable is completely seating in the connector. 3. Rotate the cam to the closed (down) position to lock in place. (See Figure 5.4.)

Figure 6.1

Cam lock in the Open (Up) position

MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

Chapter 6 Service and Repair

49

Figure 6.2

Display Cable Insertion

Figure 6.3

Cam lock in the closed (down) position

MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

Chapter 6 Service and Repair

50

6.1.3

CPU SUBASSEMBLY REMOVAL AND REPLACEMENT:

NOTE: Using a magnetic screwdriver is very helpful in retaining the screws during removal and installation. Removal: 1. Disconnect all field wiring from the I/O board. 2. Disconnect all Serial Communications from the Power Supply/COM board. 3. Disconnect Mains Power from the Power Supply/COM board. 4. Disconnect the flat display cable (after releasing the cam lock) and display power cable. 5. Disconnect the W&M Access/Program Mode switch cable from the CPU board. 6. Remove the four chassis mounting screws (not the mounting screws for the I/O board or Power Supply / COM board. 7. Carefully remove the CPU chassis from inside the base by removing the CPU board side of the chassis first. Installation: 1. Carefully insert the CPU chassis back into the enclosure. 2. Install the chassis mounding screws. 3. Connect the W&M Access/Program Mode switch cable to the CPU board. 4. Reconnect the display power cable and the flat display cable (remember to secure the cam lock). 5. Connect the Mains Power to the Power Supply/COM board. 6. Connect all Serial Communications to the Power Supply/COM board. 7. Connect all field wiring to the I/O board.

MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

Chapter 6 Service and Repair

51

6.1.4

DISPLAY SUBASSEMBLY REMOVAL AND REPLACEMENT:

Removal: 1. Disconnect the flat display cable (after releasing the cam lock), display power cable and the keypad cable. 2. While supporting the display subassembly, remove the four mounting screws. 3. Do not attempt to disassemble the display subassembly. Return entire subassembly to Toptech for repair after receiving an RMA number. Installation: 1. While supporting the display subassembly, install the four mounting screws. 2. Connect the keypad cable, display power cable and the flat display cable. 3. Verify routing and clearance of the cable

6.1.5

KEYPAD REMOVAL AND REPLACEMENT:

Removal: 1. Using a security screwdriver bit (available from Toptech), remove all security screws holding on the Keypad bezel. 2. Remove the bezel. 3. Using a flat screwdriver, carefully pry out the keypad. 4. Disconnect the keypad cable from the back of the keypad. Installation: 1. Connect the keypad cable to the back of the keypad. 2. Carefully install the keypad into the cover. 3. Install the keypad bezel. 4. Using a security screwdriver bit, install all the bezel holding security screws.

6.1.6

KEYPAD BARRIER CIRCUIT REMOVAL AND REPLACEMENT:

Removal: 1. Disconnect the keypad cable from the display subassembly. 2. Remove the four screws holding barrier circuit box. 3. One by one, move over the keypad wires to a new barrier circuit. Installation: 1. Reinstall the barrier circuit box with the three holding screws. 2. Connect the keypad cable to the display subassembly.

MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

Chapter 7 - Appendix

52

CHAPTER 7

APPENDIX

Figure 7.1

Unit Outline Drawing Front View

Figure 7.2

Unit Outline Drawing Bottom View

MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

Chapter 7 - Appendix

53

Figure 7.3

Unit Outline Drawing Side View

Figure 7.4

Replacement Parts SMP Base Drawing NOTE: TT PN = Toptech Part Number.

MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

Chapter 7 - Appendix

54

Figure 7.5

Exploded view front panel assembly

Figure 7.6

Microprocessor Board

MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

Chapter 7 - Appendix

55

Figure 7.7

Power Supply Board

Figure 7.8

I/O Board.

MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

Chapter 7 - Appendix

56

Figure 7.9

Power Supply / Comm Board & I/O Board Chassis

MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067