Produced on 11/30/2013 with Xpress Selection V6.5.3 - database Central 9.2.

8
Project name Project address Reference Client name Al Wafaa Bakery -

Selection parameters of the indoor units can be found under the chapter Indoor unit details Selection parameters of the outdoor units can be found under the chapter Outdoor unit details Only the data published in the data book are correct. This program uses close approximations of these data.

1. Material List
Model RXYQ12T RXYQ18T FXSQ140P FXSQ40P KHRQ22M29T9 KHRQ22M64T KHRQ22M75T BRC1E52A/B BHFQ22P1007 Piping 1/4" Piping 3/8" Piping 1/2" Piping 5/8" Piping 3/4" Piping 7/8" Piping 1 1/8" Piping 1 3/8" Qty Description 1 Heat pump/Heating only VRV IV HP NCH 1 Heat pump/Heating only VRV IV HP NCH 6 VRV FXSQ - Conceiled ceiling mounted 1 VRV FXSQ - Conceiled ceiling mounted 1 REFNET branch piping kit 3 REFNET branch piping kit 2 REFNET branch piping kit 7 Remote controller 1 Outdoor unit multi connection piping kit for 2 outdoors 8.0m 31.0m 8.0m 42.0m 5.0m 1.0m 12.0m 5.0m

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection Program.

Page 1

2. Indoor Unit Details


2.1. Table of Abbreviations
Name FCU Tmp C Rq TC TC Rq SC SC Tmp H Rq HC HC Suct Disch Airflow Sound PS MCA Fuses WxHxD Wght Logical name of the device Device model name indicates a model size down due to tolerance Indoor conditions in cooling (dry bulb temp. / wet bulb temp.) Required total cooling capacity +/- x% - Applied indoor cooling capacity safety factor or tolerance Available total cooling capacity Required sensible cooling capacity Available sensible cooling capacity Indoor temperature in heating Required heating capacity +/- x% - Applied indoor cooling capacity safety factor or tolerance Available heating capacity Suction temperature Discharge temperature Supplied airflow Sound pressure low and high Power supply (voltage and phases) Minimum Circuit Amps Fuses WidthxHeightxDepth Weight of the device

PI-C 50Hz Power input in cooling at 50Hz PI-C 60Hz Power input in cooling at 60Hz PI-H 50Hz Power input in heating at 50Hz PI-H 60Hz Power input in heating at 60Hz

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection Program.

Page 2

2.2. Out 1 - RXYQ30T


Actual capacity data at conditions and connection ratio (117%) as entered
Name Ind 1 Ind 2 Ind 7 Ind 3 Ind 4 Ind 5 Ind 6 FCU FXSQ140P FXSQ140P FXSQ40P FXSQ140P FXSQ140P FXSQ140P FXSQ140P Tmp C F 74.7 / 61.5 74.7 / 61.5 74.7 / 61.5 74.7 / 61.5 74.7 / 61.5 74.7 / 61.5 74.7 / 61.5 Rq TC BTU/h 42000 42000 12000 42000 42000 42000 42000 TC BTU/h 45410 45410 12682 45410 45410 45410 45410 Rq SC BTU/h n/a n/a n/a n/a n/a n/a n/a SC BTU/h 36725 36725 12011 36725 36725 36725 36725 Tmp H F 71.6 71.6 71.6 71.6 71.6 71.6 71.6 Rq HC BTU/h n/a n/a n/a n/a n/a n/a n/a HC BTU/h 57324 57324 16037 57324 57324 57324 57324

The sum of the required indoor unit capacities is 264000BTU/h for cooling and 0BTU/h for heating. However, the outdoor unit selection uses reduced load values for cooling of 250800BTU/h (= -5%). Be aware that unrealistic reductions may lead to reduced comfort levels, different noise levels or increased wear and tear.

Discharge temperature
Name Suct F Ind 1 Ind 2 Ind 7 Ind 3 Ind 4 Ind 5 Ind 6 73.4 73.4 73.4 73.4 73.4 73.4 73.4 Condition 1 Disch F 90.2 90.2 87.2 90.2 90.2 90.2 90.2 Airflow cfm 1624 1624 565 1624 1624 1624 1624 Suct F 71.6 71.6 71.6 71.6 71.6 71.6 71.6 Condition 2 Disch F 97.4 97.4 92.8 97.4 97.4 97.4 97.4 Airflow cfm 1624 1624 565 1624 1624 1624 1624

Condition 1: The discharge temperature is calculated for an ambient temperature of 5.0F and a room temperature of 73.4F, as specified in the Preferences window. It also uses the maximum connection ratio of the installation and the corresponding fan speed of the indoor units. Condition 2: The discharge temperature is calculated using the design ambient temperature 42.8F, a room temperature of 71.6F and an operational connection ratio of maximum 130%. The analysis of the suction and discharge temperature values may help in preventing a cold draft and to ensure a thermal comfort level. The discharge temperature of condition 2 is lower than 95.0F. Reducing the connection ratio may compensate this and may raise the discharge temperature improving the thermal comfort level.
Name Ind 1 Ind 2 Ind 7 Ind 3 Ind 4 Ind 5 Ind 6 Sound dBA 34-42 34-42 29-37 34-42 34-42 34-42 34-42 220V 1ph 220V 1ph 220V 1ph 220V 1ph 220V 1ph 220V 1ph 220V 1ph PS MCA A 3.1 Factory Std 3.1 Factory Std 1.2 Factory Std 3.1 Factory Std 3.1 Factory Std 3.1 Factory Std 3.1 Factory Std Fuses WxHxD mm 1400x300x700 1400x300x700 700x300x700 1400x300x700 1400x300x700 1400x300x700 1400x300x700 Wght kg 47 47 26 47 47 47 47 PI-C 50Hz kW 0.261 0.261 0.192 0.261 0.261 0.261 0.261 PI-C 60Hz kW 0.261 0.261 0.192 0.261 0.261 0.261 0.261 PI-H 50Hz kW 0.249 0.249 0.180 0.249 0.249 0.249 0.249 PI-H 60Hz kW 0.249 0.249 0.180 0.249 0.249 0.249 0.249

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection Program.

Page 3

Outdoor unit placed at the same level as the indoor units.

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection Program.

Page 4

3. Outdoor Unit Details


3.1. Table of Abbreviations
Name Model Comb Tmp C CC Rq CC EER ESEER Tmp H HC Rq HC COP Piping Bse Refr Logical name of the device Device model name Connection ratio Outdoor temperature in cooling Available cooling capacity Required cooling capacity EER at selection and nominal conditions European Seasonal Energy Efficiency Ratio Outdoor conditions in heating (dry bulb temp. / wet bulb temp.) Available heating capacity (integrated heating capacity) Required heating capacity COP at selection and nominal conditions Largest distance from indoor unit to outdoor unit Standard factory refrigerant charge (5m actual piping length) excluding extra refrigerant charge For calculation of extra refrigerant charge refer to the databook Ex Refr PS MCA MFA Run Amps St Curr Fuses WxHxD Wght Extra refrigerant charge Power supply (voltage and phases) Minimum Circuit Amps Maximum Fuse Amps Running Amps Starting current Fuses WidthxHeightxDepth Weight of the device

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection Program.

Page 5

3.2. Outdoor Details


Name Out 1 Name Out 1 Model RXYQ30T Model RXYQ30T * RXYQ18T * RXYQ12T Comb % 117 PS 400V 3Nph 32.5 22.7 40 25 24.2 14 cfr. local legislation 1240x1680x765 cfr. local legislation 930x1680x765 324 240 Tmp C F 95.0 MCA A CC BTU/h 252619 MFA A Rq CC BTU/h 250800BTU/h Run Amps A 3.9 / 3.5 6.6 Fuses EER ESEER Tmp H F 42.8 / 36.0 HC BTU/h 283879 WxHxD mm Wght kg Rq HC BTU/h 3.4 / 4 COP Piping m 28.4 Bse Refr kg 18.0 Ex

St Curr A

Sufficient distance should be respected between the modules according to the service & operation space rules as mentioned in the databook.

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection Program.

Page 6

4. Piping Diagrams
Pipes marked with * in the diagrams must be connected to the device with a reducing joint.

4.1. Piping Out 1


Out 1 RXYQ30T RXYQ18T RXYQ12T

5/8"x1 1/8" BHFQ22P1007 3.0m [3] 3/4"x1 3/8"

1/2"x1 1/8"

5.0m [2] 3/8"x5/8" KHRQ22M75T Ind 1 FXSQ140P

2.0m 3/4"x1 3/8"

5.0m [2] 3/8"x5/8" KHRQ22M75T Ind 2 FXSQ140P

4.0m 5/8"x1 1/8"

8.0m [3] 1/4"x1/2" KHRQ22M64T Ind 7 FXSQ40P

7.0m 5/8"x1 1/8"

5.0m [2] 3/8"x5/8" KHRQ22M64T Ind 3 FXSQ140P

1.0m 5/8"x1 1/8"

5.0m [2] 3/8"x5/8" KHRQ22M64T Ind 4 FXSQ140P

1.0m 3/8"x7/8"

5.0m [2] 3/8"x5/8" KHRQ22M29T9 Ind 5 FXSQ140P 5.0m [2] 3/8"x5/8"

Ind 6 FXSQ140P

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection Program.

Page 7

5. Wiring Diagrams
P1P2 = Please select the cable type and size in accordance with the databook. F1F2 = Please select the cable type and size in accordance with the databook.

5.1. Wiring Out 1


Out 1 RXYQ30T IN F1,F2 RXYQ18T Q1,Q2 RXYQ12T Q1,Q2 L1,L2,L3,N 23A 3Nph Ind 7 FXSQ40P F1,F2 P1,P2 L,N P1,P2 L,N P1,P2 L,N P1,P2 L,N P1,P2 L,N 3.1A 1ph 3.1A 1ph 3.1A 1ph 3.1A 1ph 1.2A 1ph BRC1E52A/B L1,L2,L3,N 33A 3Nph F1,F2 Ind 2 FXSQ140P P1,P2 L,N 3.1A 1ph BRC1E52A/B F1,F2 Ind 1 FXSQ140P P1,P2 L,N 3.1A 1ph BRC1E52A/B 20A 1ph

Ind 3 FXSQ140P F1,F2

BRC1E52A/B

Ind 4 FXSQ140P F1,F2

BRC1E52A/B

Ind 5 FXSQ140P F1,F2

BRC1E52A/B

Ind 6 FXSQ140P F1,F2

BRC1E52A/B

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection Program.

Page 8

6. Device Options
6.1. Outdoor Unit Options
Model Description Used by Out 1 [RXYQ30T] BHFQ22P1007 Outdoor unit multi connection piping kit for 2 outdoors

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection Program.

Page 9