You are on page 1of 5

1.

Calculador de volumen (Mire la ficha de volumen para otras opciones)


Rectangulo Cilindro
Altura (H) (m) Altura (m)
Ancho (W) (m) Diametro (m)
Largo (L) (m)
Volumen
0.0
m
3
Volumen
0.0
m
3
Nota: Si el espacio es rectangular con un componente cilindrico, entre los datos en el rea marcada.
El volumen total ser usado en la seccin 2 y 4, a menos que un valor sea ingresado en la seccin 3
2. Tasa de cambio de aire (3. Ingreso manual de datos)
CES:
CAH CES 0.0 MCM 40.0
m
3
100 MCM
2.a. Tiempo requerido para generar 7.5 Cambios de Aire basado en ingreso manual de datos
min
4. Tasa de purga
Volume 40.0
m
3
Volume 40.0
m
3
CES 100.0 CMM CES 100.0 MCM
Contaminacin inicial 16 ppm/% Contaminacin inicial 20 ppm/%
Nivel objetivo 1 ppm/% Tiempo venteo 10 minutos
Tiempo
Time (min) --
1.1 minutos Nivel Objetivo 0.0 ppm/%
Otras notas:
K-C OS&H Team 04/08/08
"Cual sera el nivel de concnetracin
de contaminantes despues de X
minutos de ventilacin?"
"Cuanto tiempo llevara reducir la concentracin
de contaminantes a niveles seguros?"
Volumen:
Precaucin: La ecuacin de cambio de aire usado en la seccin 2, asume
concentraciones inicilaes estables y mexcla uniforme de aire y contaminante en
todo el espacio
"Que Capacidad Efectiva de Soplado (CES) necesita
para generar X Cambios de Aire por Hora (CAH)?
3
1. Volume Calculator (See Volume Worksheet for additional options)
Rectangle Cylinder
Height (ft) Height (ft)
Width (ft) Diameter (ft)
Length (ft)
Volume
0.0
ft
3
Volume
0.0
ft
3
Note: If the space has a rectangular & a cylindrical component, enter data in both areas.
The total volume will be used in sections 2 and 4, unless a value is entered in section 3.
2. Air Exchange Rate (3. Manual Data Entry)
Override
EBC:
ACH 20 EBC 0.0 CFM 0.0
ft
3
CFM
2.a. Time to Achieve 7.5 Air Exchanges based on Manual Data
min
4. Rate of Purging
Volume 0.0
ft
3
Volume 0.0
ft
3
EBC 0.0 CFM EBC 0.0 CFM
Initial contaminant level ppm Initial contaminant level ppm
Target level ppm Purge time minutes
Time
Time (min) --
#DIV/0! minutes Target Level #DIV/0! ppm
Other Notes:
K-C OS&H Team 04/08/08
"What will be the level of a hazardous
material after X minutes of purging?"
"How long will it take to lower the concentration
of a hazardous material to a safe level?"
Override
volume:
Caution: The equations used in the rate of purging section assume "steady-
state" initial concentrations and complete mixing of air in the space.
"What is the Effective Blower Capacity (EBC) needed to
achieve X Air Changes per Hour (ACH)?
5. Espacios complejos Calculador de volumen otros espacios:
Nota: puede entrar valores en pies o metros
Componente
espacio
Volumen
(ft
3
o m
3
)
Esfera Cono
1 567.0 (4/3 p r
3)
(p r
2
*h/3)
2 743.0
3 Diametro 8 Alto
4 Diamtero
5
6
Volumen
268.1
Volumen
7
8
9
10
11
12
13 Convertir Convertir
14 Pies
15 a 0.00 Metros a 0.00
Total 1310.0
Convertir Convertir
m
3
a 0.00
ft
3
a 0.00
Calculador de volumen otros espacios:
Nota: puede entrar valores en pies o metros
4
8
67.0
Metros
Pies
m
3
ft
3

You might also like