Safety Precautions
Product Contents
Product PIN Diagram
LED indicators
Product Dimensions
Installation of Panel with Casing
Wire Legend
Power Wiring Diagram
FR1200 Connection
Weigand Connection
Exit button Connection
Lock connection
Door Sensor Connection
Aux. Input Connection
Aux. Output Connection
Ethernet Connection
RS485 Connection
DIP switch settings
Electrical Specifications
Troubleshooting
Specifications
1
02
04
06
06
07
08
09
10
11
12
12
13
13
15
15
16
17
18
19
20
21
1
2
Safety Precautions
Do not install the device in an area
subject to direct sun light, Humidity
or dust
Do not place a magnet near the
product. Magnetic objects such as
magnet, CRT, TV, monitor or speaker
may damage the device.
Do not place the device next to
heating equipments
Be careful not to let liquid like
water, drinks or chemicals leak
inside the device.
Clean the device often to remove
dust on it
01 02 03
04 05 06
Do not let children touch the
device without supervision.
The list below is to keep users safety and prevent any loss. Please read carefully before installation.
3
Safety Precautions
The list below is to keep users safety and prevent any loss. Please read carefully before installation.
Do not drop the device. Do not use the device for any
other purpose than specified.
Do not disassemble, repair or
alter the device.
07 08
In cleaning, do not splash water
on the device but wipe it out with
smooth cloth or towel.
09
Contact your nearest dealer in
case of a trouble or problem.
Do not damage the device
10 11 12
4
Product Contents
Basic Contents
Inbio460
Wall Mounting Screws 2 pcs. Wall Plugs 2 pcs. Surge Suppressing Diode 4 pcs.
Screw Driver 2 pcs. Software CD InBio Installation Guide
5
Product Contents
Optional accessories
Weigand Card Reader Prox Card
Card Enroller
ZK4500 FP Enrollment reader
FR1200 FP Reader K1-1 Exit Button
Inbio Metal Case RS485 convertor
6
Product PIN Diagram
#4 Door Card
Reader
#4 Door Exit
Button
#3 Door Card
Reader
#3 Door Exit
Button
#2 Door Exit
Button
#2 Door Card
Reader
#1 Door Card
Reader
#1 Door Exit
Button
State Indictor
FR1200
Fingerprint
Reader
Aux Input 4
Aux Input 1
SD Card Slot
LINK LED
ACT LED
Ethernet Port
DIP Switch
PC RS485 Port
Aux Output 1
Aux Output 4
#1 Door Lock
#4 Door Sensor
Lock Power
Inbio Power
LED indicators
LINK
(Green)
LED solid green indicates
TCP/IP communication is
normal
ACT
(Yellow)
Flashing LED indicates data
communication is in progress
EXT RS485
(Yellow &
Green)
Flashing LED indicates data
communication in progress
PC RS485
(Yellow &
Green)
Flashing LED indicates data
communication is in progress
POWER
(Red)
Flashing LED indicates the
panel is powered on.
RUN
(Green)
Flashing LED indicates that
panel is in normal working
mode
CARD
(Yellow)
Flashing LED indicates that
the card is read by the panel.
#1 Door Sensor
#4 Door Lock
7
Inbio460
Product Dimension
Dimensions(L*W*H): 400 *90.5*330mm
InBio-Casing
226mm
(8.89in.)
106mm
(4.17in.)
106mm
(4.17in.)
36mm
(1.42in.)
Dimensions(L*W*H):226 106 36mm
8.89 4.17 1.42(inches)
400mm
(15.7in.)
330mm
(13.0in.)
330mm
(13.0in.)
90.5mm
(3.56in.)
15.7 13.0 3.56(inches)
8
Installation of Panel & Case
Metal Case
Wire Legend
9
Detector Infrared sensors FR1200 Inbio-Box #1Exit Button #1Card Reader #4 Exit Switch #4 Card Reader
12V
Power Supply Normally Open Lock Normally Close Lock Alarm Floodlight RS485 Convertor Network
12V DC
Power
D C
Power wiring diagram
10
With
Backup Battery
AC
AC
Switching power supply
Inbio460
AC
AC
Switching power supply
Inbio460
Backup Battery
+
-
110-220V
110-220V
Without
Backup Battery
FR1200 Connection
11
#1 FR1200 #2 FR1200 #3 FR1200 #8 FR1200
DIP Switch Setting For FR1200 Device ID
1. There are six DIP switches on the back of FR1200 , Switches 1-4 is for RS485
address , switch 5 is reserved , switch 6 is for reducing noise on long RS485 cable.
2. Set the odd number for IN reader, and the even number for OUT reader(for eg.
For two readers for one door- the RS485 address 1 is for IN reader, RS485 address
2 is for OUT reader )
3. If FR1200 is powered from Inbio460 panel ,the length of wire should be less
than 100 meters or 330 ft.
4. The External RS485 interface can supply maximum 500mA current , The
FR1200s startup current is 240mA. So Inbio460 only can only power two FR1200s.
5. If the cable length is more than 200 meters or 600 ft , the number 6 switch
should be ON as below



Important Notes
12V DC
12V DC
Distance
More than 200 meters
Weigand Connection
12
Weigand Card Reader
Exit Button Connection
Beeper
Green LED
Weigand D1
Weigand D0
GND
DC+(6-14V)
BUT
GND
DV12V+
DV12V-
NO
COM
NC
separate power supply
Notice
ZK ABK Exit Button
K1-1 Exit Switch
12V DC Power Supply
13
Lock Connection
12V DC
GND
Sensor
Sensor
12V DC
GND
GND
12V DC
Sensor
Sensor
GND
12V DC
FR107
FR107 For Normally Open -Lock powered from panel power supply
For Normally Closed -Lock powered from panel power supply
Lock Connection
14
Important Notes:

InBio is set to supply lock power by default from built-in
power supply , If you want to use external power supply ,
you must take the following steps
1. Take apart the cover of inbio460
2. Select the desired lock relay and find its jumpers
3. Take off the jumpers and change to
4. Connect the lock as shown in the diagram below.
Steps:










Inbio460
Detach from Rail
Remove Top Cover Lock Relay
Terminals Default Setting Changed Setting Jumpers
FR107
GND
12V DC
SEN SEN GND 12V DC
5 1 1 5 5 1 1 5
Connecting a Lock with External Power supply
Switching Wet Contact to Dry Contact
15
Auxiliary Input/Output
Aux. Input Connection
Aux. output Connection
COM
NO
NC
GND
12V DC
COM
NO
NC
GND
12V DC
Smoke Detector
Alarm
16
Ethernet Connection
Direct connection
To connect Inbio460 with a PC directly, connect both devices with a straight network cable. As the Inbio460 supports auto MDI/MDIX ,
it is not necessary to use a crossover type cable.
Important Notes:
ZK4500 Enrollment
reader
CR10 Card Issuer
1. Both 10Base-T and 100Base-T
are supported
2. The cable length must be less
than 100 meters or 330 ft.
3. For more than 100 meters ,
please use HUB to amplify the
signal
TCP/IP
CR10 Card Issuer
ZK4500 Enrollment
reader
The CR10 and ZK4500 are connected to the server
using USB connection.
17
RS485 Connection
Important Notes
#1 Inbio460
#63 Inbio460
Do's and Dont's for RS 485 connection
RS485-
RS485+
GND
1. RS485 communication wires should be a shielded or twisted pair cable.
RS485 communication wires should be connected in a bus cascade instead
of a star form, to achieve a better shielding effect by reducing signal
reflection during communications.
2. A single 485 bus can be connected with 63 access control panels at the
most, but preferably less than 32 panels should be connected.
3. To eliminate signal attenuation in communication cables and suppress
interference, if the bus is longer than 200 meters, set the number 8 DIP
switch to the ON position. This is equivalent to a parallel connection of one
120ohm resistance between the 485+ and 485- lines.
Distance
More than 200 meters
#1 Inbio460
#* Inbio460
18
DIP Switch Setting
Introduction RS485 Address
1. Number 1-6 are reserved to set the device number for RS485
communication. The code is binary, and the numbering starts from left to
right. When the switch is set to ON position, it indicates 1 (on); when the
switch is set downwards, it indicates 0 (off). For example, to set a device
number 39=1+2+4+32, which corresponds to the binary code 111001, put
number 1, 2, 3, and 6 to ON position, as illustrated below.
2. For more details, please check the table at the end of this document
Restore factory setting
1. If you forget the inBio IP address or the device does not work
normally, you can use the number 7 terminal to restore inbio460 to
factory default settings. The parameters which gets reset are
device IP address, communication password ,gateway ,subnet mask.
2. The switch is OFF by default. When it is moved upwards and
downwards for three times within 10 seconds and finally returned
to OFF position, the factory settings will be restored after the
access control panel is restarted.
1 times 2 times 3 times OFF
Terminal Resistance
1. Number 8 is for setting the RS485 termination resistance. Putting the
switch to ON position is equivalent to parallel connection of a 120ohm
termination resistance between 485+ and 485-
2. As shown in diagram below, for more info please read RS485 connection
important notes
120ohm
Electrical Specification
19
Min. Typ. Max. Notes
Working power supply
Voltage(V) 9.6 12 14.4 Use regulated DC power adaptor only
Current(A) 2
Electronic lock relay output
Switching voltage(V) 36V Use regulated DC power adaptor only
Switching Current(A) 2
Auxiliary relay output
Switching voltage(V) 36V Use regulated DC power adaptor only
Switching Current(A) 1.25
Switch Aux. input
VIH (V) TBD
VIL (V) TBD
Pull-up resistance () 4.7k The input ports are pulled up with 4.7k resistors
WEIGAND Input
Voltage(V) 10.8 12 13.5
Current(mA) 500
ZK Electronic lock
Voltage(V) 10.8 12 13.2
Current(mA) 500
Troubleshooting
20
1. Fingerprint can not be read well or it takes too long.
Check whether a finger or fingerprint sensor is stained with sweat, water, or dust
Retry after cleaning the finger and fingerprint sensor with dry cloth.
If a finger is way too dry, rub your finger on the palm and retry.
Try to reset fingerprint sensor by pressing the reset button at the bottom of the reader

2. Fingerprint is matched but authorization keeps failing.
Check whether the user access is restricted.
Inquire with administrator whether the enrolled fingerprint has been deleted from the device
for some reason.

3. How Many kinds of WEIGAND format can be supported.
The panel is set to read 26 bit by default.
However there are 9 other bit formats which can be selected from the software. In addition you
can also define your custom bit format.

4. How many verification modes can be support.
Card Only
Fingerprint Only
Password Only
Card plus fingerprint
Card plus password
Card or fingerprint

Reset Button
Specification
21
Communication RS485, Ethernet
Baud Rate for RS485 9600-115200 baud
Power Supply 12V DC, 3A
Device Capacity Card capacity 30,000 ; Log events capacity 100,000 ; Finger capacity 3,000
LED Indicator Indication for communication, power, status and prox card
Environment Operating Temp: 32-113 F (0-45 C) Operating Humidity: 20% to 80%
Number of doors controlled four door one way or two door two way
Number of card readers supported 4
Number of FR1200 supported 8
FR1200 Sensor Fingerprint sensor 500dpi Optical / Optical sensor
Types of readers supported 26-bit Weigand, others upon request
Number of Inputs 12 (4 Exit Device, 4 Door Status, 4 AUX)
Number of Outputs 8 (4- Form C relay for lock and 4- Form C relay for Aux output)
Weight 7.8lbs (3.55kg)
Enclosure Stainless Steel
Mounting Wall Mount
Dimensions (Bundle Only) 15.7in. 3.56in. 13.0in. 400mm(L) X 90.5mm(W) X 330mm(H)
Dimensions ( Board Only) 8.89in. 4.17in. 1.42in. 226mm(L) X 106mm(W) X 36mm(H)
CPU 32 bit 400MHz
RAM 32MB
Flash 128MB
Certified
22
Place Address
Switch Setting
1 2 3 4 5 6
Address No. 1 2 4 8 16 32
01 ON OFF OFF OFF OFF OFF
02 OFF ON OFF OFF OFF OFF
03 ON ON OFF OFF OFF OFF
04 OFF OFF ON OFF OFF OFF
05 ON OFF ON OFF OFF OFF
06 OFF ON ON OFF OFF OFF
07 ON ON ON OFF OFF OFF
08 OFF OFF OFF ON OFF OFF
09 ON OFF OFF ON OFF OFF
10 OFF ON OFF ON OFF OFF
11 ON ON OFF ON OFF OFF
12 OFF OFF ON ON OFF OFF
13 ON OFF ON ON OFF OFF
14 OFF ON ON ON OFF OFF
15 ON ON ON ON OFF OFF
16 OFF OFF OFF OFF ON OFF
17 ON OFF OFF OFF ON OFF
18 OFF ON OFF OFF ON OFF
19 ON ON OFF OFF ON OFF
20 OFF OFF ON OFF ON OFF
21 ON OFF ON OFF ON OFF
22 OFF ON ON OFF ON OFF
23 ON ON ON OFF ON OFF
24 OFF OFF OFF ON ON OFF
25 ON OFF OFF ON ON OFF
26 OFF ON OFF ON ON OFF
27 ON ON OFF ON ON OFF
28 OFF OFF ON ON ON OFF
29 ON OFF ON ON ON OFF
30 OFF ON ON ON ON OFF
31 ON ON ON ON ON OFF
32 OFF OFF OFF OFF OFF ON
Place Address
Switch Setting
1 2 3 4 5 6
Address No. 1 2 4 8 16 32
33 ON OFF OFF OFF OFF ON
34 OFF ON OFF OFF OFF ON
35 ON ON OFF OFF OFF ON
36 OFF OFF ON OFF OFF ON
37 ON OFF ON OFF OFF ON
38 OFF ON ON OFF OFF ON
39 ON ON ON OFF OFF ON
40 OFF OFF OFF ON OFF ON
41 ON OFF OFF ON OFF ON
42 OFF ON OFF ON OFF ON
43 ON ON OFF ON OFF ON
44 OFF OFF ON ON OFF ON
45 ON OFF ON ON OFF ON
46 OFF ON ON ON OFF ON
47 ON ON ON ON OFF ON
48 OFF OFF OFF OFF ON ON
49 ON OFF OFF OFF ON ON
50 OFF ON OFF OFF ON ON
51 ON ON OFF OFF ON ON
52 OFF OFF ON OFF ON ON
53 ON OFF ON OFF ON ON
54 OFF ON ON OFF ON ON
55 ON ON ON OFF ON ON
56 OFF OFF OFF ON ON ON
57 ON OFF OFF ON ON ON
58 OFF ON OFF ON ON ON
59 ON ON OFF ON ON ON
60 OFF OFF ON ON ON ON
61 ON OFF ON ON ON ON
62 OFF ON ON ON ON ON
63 ON ON ON ON ON ON
PC485 Table
ZK USA office:
201 Circle Drive North, Suite 116
Piscataway, NJ 08854, USA
Tel: +1 732-412-6007
Fax +1 732-412-6008
sales@zkaccess.com
zkaccess.com
Copyright 2013 ZKAccess Inc. All right reserved.
ZKAccess May, at any time and without notice , Make changes or
improvements to the product and services offered and/or cease
producing or commercializing them.
Functions and specifications of the product are subject to change without notice due to quality enhancement or function update. For any inquiry
for the product, please contact ZKAccess Inc .

You might also like