You are on page 1of 2

X292 - X293 - X294 - X295

(For Pump Prex Identication see News & Views 0052)


HIGH HEAD
EXPLOSION PROOF
SUBMERSIBLE
SEWAGE
OR DEWATERING PUMP
COMPARE THESE FEA TURES
FM listed motor for Class 1, Division 1, Group C & D
environments.
Non-clogging vortex impeller design bronze class
88-8-0-4.
Stainless steel rotor shaft.
Durable cast construction. Cast iron cover, motor
adapt er and pump housing. No sheet metal parts to
rust or corrode. All cast iron class 30, 30000# tensile
strength.
Stainless steel screws and handle.
20 ft. UL Listed 5-wire (1 PH) or 8-wire (3 PH) neoprene
cord. Extra cords lengths available in 25'-35'-50' length
only. Sensor leads & power leads in one cord for easy
installation.
1" NPT threaded conduit connection for protecting
cords in those extra heavy duty applications.
Moisture sensors prewired in motor housing (requires
indicator in panel).
Zoeller custom designed panels with intrinsically safe
re lays and moisture indicator are required.
3 phase models available.
Motor - 60 Hz, 3450 RPM, oil-lled, her met i cal ly
sealed, automatic reset thermal overload protected
(3 phase requires circuit in control panel).
Maximum temperature for sewage or dewatering
104F (40C).
Shaft Seal - Stainless steel wetted parts, carbon &
ceramic rotary face seal.
Upper ball bearing and lower ball bearing running in
bath of oil.
Buna-n square ring seals.
All models pass 2" spherical solids.
Major width 13
5
/16". Height 22".
Available in nonautomatic units only.
When ordering specify 2" or 3" NPT female anged
vertical discharge.
100% computerized testing and 100% tested sub-
merged in water.
Corrosion resistant powder coated epoxy nish.
Note: The sizing of sewage systems normally requires vari-
able level oat(s) controls and properly sized basins to achieve
required pumping cycles.
SECTION: 2.40.040
FM1702
0206
Supersedes
0305
*See back page For FM Listing.
Product information presented
here re ects con di tions at time
of publication. Consult factory
re gard ing dis crep an cies or
in con sis ten cies. MAIL TO: P.O. BOX 16347 Louisville, KY 40256-0347
SHIP TO: 3649 Cane Run Road Louisville, KY 40211-1961
(502) 778-2731 1 (800) 928-PUMP FAX (502) 774-3624
visit our web site:
www.zoeller.com
Copyright 2006 Zoeller Co. All rights reserved.
Nonautomatic Models for
intrinsically safe variable
level sys tems
Not for use in acidic, methanol, or
ethyl acetate atmospheres.
Standard 3600 & 3615
6 1/2
8 3/4
21 1/2
6
4 9/16
4 9/16
22
CHECK VALVE
2" NPT
OR
3" NPT
AVAILABLE
1 1/4" - 11 1/2 NPT
RESERVE POWERED DESIGN
For unusual conditions a reserve safety factor is en gi neered into the design of every Zoeller pump.
Standard all models - 20 ft. cord - H.P.
292 MODELS Control Selection Listing
Single Seal Volts - Ph Mode Amps Simplex Duplex FM
NX292 115 1 Non 15.0 1 & 3 1 & 3 or 2 Y
Standard all models - 20 ft. cord - 1 H.P.
293 MODELS Control Selection Listing
Single Seal Volts - Ph Mode Amps Simplex Duplex FM
EX293 230 1 Non 10.2 1 & 3 1 & 3 or 2 Y
IX293 200 1 Non 12.0 1 & 3 1 & 3 or 2 Y
FX293 230 3 Non 7.6 1 & 3 1 & 3 Y
JX293 200 3 Non 8.2 1 & 3 1 & 3 Y
GX293 460 3 Non 4.0 1 & 3 1 & 3 Y
BAX293 575 3 Non 3.3 1 & 3 1 & 3 Y
Standard all models - 20 ft. cord - 1 H.P.
294 MODELS Control Selection Listing
Single Seal Volts - Ph Mode Amps Simplex Duplex FM
EX294 230 1 Non 13.7 1 & 3 1 & 3 or 2 Y
IX294 200 1 Non 17.8 1 & 3 1 & 3 or 2 Y
FX294 230 3 Non 9.5 1 & 3 1 & 3 Y
JX294 200 3 Non 10.8 1 & 3 1 & 3 Y
GX294 460 3 Non 4.8 1 & 3 1 & 3 Y
BAX294 575 3 Non 3.8 1 & 3 1 & 3 Y
Standard all models - 20 ft. cord - 2 H.P.
295 MODELS Control Selection Listing
Single Seal Volts - Ph Mode Amps Simplex Duplex FM
EX295 230 1 Non 17.1 1 & 3 1 & 3 or 2 Y
IX295 200 1 Non 20.5 1 & 3 1 & 3 or 2 Y
FX295 230 3 Non 12.2 1 & 3 1 & 3 Y
JX295 200 3 Non 14.3 1 & 3 1 & 3 Y
GX295 460 3 Non 6.1 1 & 3 1 & 3 Y
BAX295 575 3 Non 4.9 1 & 3 1 & 3 Y
SELECTION GUIDE
1. See FM1705 for correct intrinsically safe simplex or duplex
panel.
2. Mechanical alternator M-Pak 10-0076 or 10-0077 (See
FM1783).
3. Variable level control switch used as a control activator.
Quantity required dependent upon panel se lec tion.
Single Seal
Weight - 125 lbs.
Copyright 2006 Zoeller Co. All rights reserved.

All installation of controls, protection devices and wiring should be done by a qualied licensed
electrician. All electrical and safety codes should be followed including the most recent National
Electric Code (NEC) and the Occupational Safety and Health Act (OSHA).
For information on additional Zoeller products refer to cat a log on Duplex and Simplex controls, FM1705;
Me chan i cal Al ter na tor, FM0495; Sump/Sewage Ba sins, FM0487; and Rail Sys tems, FM0787.
Model 293 should
not be subjected to less than 15
feet TDH.
SK1914
PUMP PERFORMANCE CURVE
MODEL X292/X293/X294/X295
130
480
T
O
T
A
L

D
Y
N
A
M
I
C

H
E
A
D
FLOW PER MINUTE
GALLONS
LITERS
0
0
10
2
5
4
15
80
10 20
160
30 40
30
6 20
8
25
10
35
12
40
240
50 60
320
70 80 110
400
90 100 120
X293
70
50
14
45
16
55
18
60
20
65
M
E
T
E
R
S
F
E
E
T
22
80
X295
800 640
170
560
150 140 160
X292
X294
720
190 180 200 210 220
75
24
9.1 30
40
60
70
Shut-off Head:
50
18.3
21.3
12.2
15.2
Feet
25
10
15
20
4.6
6.1
7.6
Meters
5 1.5
3.0
75 ft.(22.9m)
Liters
--
50 ft.(15.2m)
--
--
363
--
182
310
409
447
--
82 212 56
42 ft.(12.8m)
-- --
--
10
--
--
38
--
--
--
48
--
91
108
75
344
409
284
140
Gal.
124
530
Liters
469
108
118
96
--
Gal.
--
140 121 458
356
62 ft.(18.9m)
--
220
13
--
94
58
59 49
23
115
89
742
Liters
515
568
625
685
150
165
136
196
Gal.
181
168
184
154
214
Gal.
199
530
223
87
435
337
636
696
583
Liters
810
753
MODEL X295 X293 X292 X294
009919

You might also like