Features

Microcontroller based DIN rail mountable automatic source changeover


with neutral isolation
Inbuilt SMPS for low power consumption
Operational status indication through LEDs
Manual reset provision for restoring supply, when in sleep mode
Automatic generator on/off facility (on special demand)
Staggered terminal design with bottom wiring for better isolation between
phase & neutral
Introducing
Automatic Changeover
with Current Limiter (ACCL)
The intelligent start-up solution
ACCL
Automatic Changeover with Current Limiter (ACCL)
An indispensable tool to automate power distribution, protect
expensive gensets and prevent fatal risks - The power instability in
developing countries along with the ineffcient rationalized power
distribution creates a need for the alternative source of power,
to back up the utility supply, and hence, most of the commercial
and residential complexes set-up alternate power sources, such
as gensets, to provide effcient back-up for their power needs.
However, most of these users of alternate power still depend on
manual change-over, which leads to issues such as increased
downtime, disruption in key activities as well as critical damage
to the expensive equipment and could also prove fatal to the
operators.
HAVELLS INDIA LTD Nations leading player in power distribution
equipment and solutions, now offers HAVELLS ACCL, a
fully automatic high precision microcontroller based Source
Changeover device, which also has current limiting function and
offers easy and controllable changeover between main power
supply and generator supply.
With these inherent strengths, HAVELLS ACCL is being increasingly
adopted by leading power consumers, both at commercial as well
as residential levels, as a strong and proven power distribution
management tool.
So go ahead, and empower your premises and power distribution
with HAVELLS ACCL today!
Functions
- When the Mains Supply is available:
a. The ACCL allows unrestricted supply from Mains in case
current is in allowable limits.
b. If the current exceed the mains rating, the load is disconnected
after a delay of 5 seconds and it will remain disconnected for
8 seconds as a warning and then automatically reconnects it.
During this period, the consumer is expected to switch off the
non-essential loads and bring it within the limit.
c. In an unlikely event, if the consumer does not switch off the non
essential loads to reduce it to within the limit, supply to the load
from the mains is automatically disconnected after 5 cycles of
interruption.
d. The supply from mains to the load can be restored after
pressing the reset button present in the front of ACCL.
- When the Mains supply fails
Without AGS (automatic generator start features) - When the
mains supply goes OFF, a consumer is automatically connected
to the generator in case generator supply is available after a
time delay of 8 to 12 seconds in order to limit the sudden load
on the generator.
With AGS (automatic generator start features) - ACCL
Provides signaling through a potential free contact for starting
the Generator (Generator must have control unit for auto
Start/off) and then consumer is automatically connected to the
generator after a time delay of 8 to 12 seconds in order to limit
the sudden load on the generator.
Once the supply goes to generator side then:
a. ACCL limits the user from drawing excess load current beyond
the pre- set limit.
b. If the current exceeds the allowable limit, the ACCL will indicate
the overload condition by glowing its overload LED. Due to
this the load is disconnected after a delay of 5 seconds and
will remain disconnected for 8 seconds as a warning and then
automatically reconnects. During this period, the consumer is
expected to switch off the non-essential loads and reduce it
within the limit.
c. In an unlikely event, if the Consumer does not switch off the
non essential loads to reduce it to within the limit, supply to
the load from the mains is automatically disconnected after 5
cycles of interruptions.
d. The supply from Gen to the load can be restored only after
pressing the Reset button present in the front of ACCL.
Technical Specications
Standard Conformity IEC 60947-6-1
No. of Poles 1P+N
Rated current (In) 30A on mains, 1.5-20A on generator
Rated voltage (Ue) 240 Vac
Rated frequency 50 Hz
Rated insulation voltage 500V
Transfer time 8 to 12 sec
Restoring Time 2 to 4 sec
Utilization Category AC 31B
Class of Equipment PC
Environment B
Indication Mains, Generator, Load, Overload
Ambient Temp. -5 to +55C
Electrical Life 6000 operations
Rated Impulse Voltage 1.5kV
Duty Uninterrupted
Pollution Degree 2
Conditional Short Circuit
Current
3kA
Protection Class IP20
Mounting standard mounting RAIL (35x7.5 mm)
Mounting Position Vertical /Horizontal
Terminal Capacity mm 10
Weight 350 gms.
ACCL
Feature Benets of Havells ACCL


L N


Main supply
N L
Input from mains supply
Input from GEN supply
Auto GEN start control unit
GEN with auto start control unit
Ignition signal to remote GEN start terminals
Output
MCB /
RCCB
N
Load
ACCL
L
SCPD 1
SCPD 2
Terminals available in ACCL for
GEN. ON/OFF feature
* SCPD can be 32A HRC FUSE or 32A MCB
Features Advantage of Havells ACCL Other Competitor Products
Compact Design
Requires less installation space, it can be ftted
in any DBs as dimension is same as 4 Pole MCB
(87.5 x 71.8 x 63)
108 x 72 x 68
Terminals for External Conductors
Prevent connection error
(Indirect pressure type )
Direct pressure type
Conditional Short Circuit Current 3 kA Not mentioned
Eco Friendly Housings Thermoplastic, PA6 FR Grade Thermoplastic
Local Reset Facility
Reset button provided, so no
extra switch required for restoring supply
Extra switching device required
for restoring supply
Overload Indication Customer knows immediately in case of overload Not provided
Standard Conformity As per IEC 60947-6-1 No marking on product
Rated Impulse Voltage 1.5kV Not mentioned
Operational Voltage 80-300 Vac 180-240 Vac
Electrical Life Longer life product (>6000 ops.) Not mentioned
Pre-Trip Indication Under
Overload Condition
Provided Not provided
Utilization Category Longer contact life (AC 31B / IEC 60947-6-1) Not mentioned
Vents Provided for Cool Running Low temperature rise No vents
ACCL Wiring Arrangement during Installation
S
W
I
/
Z
H
D
L
E
0
0
0
1
2
/
J
U
L
1
1
/
A
P
R
1
2
71.8
8
7
.
5
Front view
3
6
4
5
63
Side view
Dimensions (in mm)
Mains Rating Gen Rating Product Code Description
ACCL
SPN 30 (6000 W) SPN 1.5 (300W) DHACOSN301X 30A/1.5A ACCL W/O GEN START/STOP
SPN 30 (6000 W) SPN 2.5 (500W) DHACOSN302X 30A/2.5A ACCL W/O GEN START/STOP
SPN 30 (6000 W) SPN 3 (600W) DHACOSN3003 30A/03A ACCL W/O GEN START/STOP
SPN 30 (6000 W) SPN 4 (800W) DHACOSN3004 30A/4A ACCL W/O GEN START/STOP
SPN 30 (6000 W) SPN 5 (1000W) DHACOSN3005 30A/5A ACCL W/O GEN START/STOP
SPN 30 (6000 W) SPN 6 (1200W) DHACOSN3006 30A/06A ACCL W/O GEN START/STOP
SPN 30 (6000 W) SPN 9 (1800W) DHACOSN3009 30A/09A ACCL W/O GEN START/STOP
SPN 30 (6000 W) SPN 12 (2400W) DHACOSN3012 30A/12A ACCL W/O GEN START/STOP
SPN 30 (6000 W) SPN 15 (3000W) DHACOSN3015 30A/15A ACCL W/O GEN START/STOP
SPN 30 (6000 W) SPN 20 (4000W) DHACOSN3020 30A/20A ACCL W/O GEN START/STOP
ACCL with Generator ON/OFF
SPN 30 (6000 W) SPN 3 (600W) DHACWSN3003 30A/03A ACCL WITH GEN START/STOP
SPN 30 (6000 W) SPN 6 (1200W) DHACWSN3006 30A/06A ACCL WITH GEN START/STOP
SPN 30 (6000 W) SPN 9 (1800W) DHACWSN3009 30A/09A ACCL WITH GEN START/STOP
SPN 30 (6000 W) SPN 12 (2400W) DHACWSN3012 30A/12A ACCL WITH GEN START/STOP
SPN 30 (6000 W) SPN 15 (3000W) DHACWSN3015 30A/15A ACCL WITH GEN START/STOP
SPN 30 (6000 W) SPN 20 (4000W) DHACWSN3020 30A/20A ACCL WITH GEN START/STOP
Price List
Havells India Ltd.
Corp Offce: QRG Towers, 2D, Sector-126, Expressway, Noida-201304 (U.P), Ph. +91-120-4771000,
Email: marketing@havells.com, www.havells.com Consumer Care No.: 1800 11 0303 (Tollfree),
011-4166 0303 (Landline), 1800 103 1313 (All Connections)
Join us on Facebook at www.facebook.com/havells and share your ways to save the planet!
Features
Microcontroller based automatic changeover with isolated neutral
Current limitation on generator side
Operational status indication through membrane keypad
Manual reset provision for restoring supply, when in sleep mode
Mode selection feature i.e automatic or manual
Automatic generator on/off facility (on special demand)
Introducing
Three Phase Automatic
Changeover with Current
Limiter (TPN ACCL)
The Intelligent start-up solution
ACCL
Three Phase Automatic Changeover with Current Limiter
(TPN ACCL)
The Power instability in developing countries along with the
inefcient rationalized power distribution creates a need for the
alternative source of power, to back up the utility supply. This further
necessitates the automation, in the distribution system as the rate
of power outage & low voltage output becomes predominantly high.
Most of the Residential & commercial processes are dependent
on power supply & if the process of changeover is manual, this
will not only create the hindrance in important activities but it may
also damage the device or machine from human error during the
changeover.
Havells TPN ACCL is a fully automatic high precision microcontroller
based device and is ideally suited for proper/efcient utilization of
standby generator used in multi-storied apartments, commercial
complexes, etc.
Functions
1. When the Mains Supply is available:
Automatic mode:
The TPN ACCL allows full load current on each phase when all
the 3 phases of mains supply is available, and when any one of
the phase fails, TPN ACCL will automatically senses and actuates
the inbuilt changeover mechanism to the generator supply.
Manual mode:
If R phase is available, it will countinue to run the load on main
supply irrespective of the availability of other phases. But if R
phase fails, the TPN ACCL will automatically senses and actuates
the inbuilt changeover mechanism to the generator supply.
Note: It is recomended to connect all essential load to R phase.
2. When the Mains supply fails
With AGS (automatic generator start feature):
TPN ACCL provides signaling through a potential free contact
for starting the Generator.
Without AGS (automatic generator start feature):
When the mains supply goes OFF, a consumer is automatically
connected to the generator in case generator supply is available,
after a time delay of 8-12 seconds in order to limit the sudden
load on the generator.
The TPN ACCL has a current limiting feature on the generator
side. If the load exceeds the allowable limit, TPN ACCL will give a
pre-trip indication and after a delay of 5 second, TPN ACCL will
trip and goes on hold. After a predetermined time delay (say 8
sec), it will again check the connected load and gives the supply
if the load is under the allowable limit. During this period, the
consumer is expected to switch off the non-essential loads and
reduce it within the limit. The overloaded phase will be indicated
through LED.
In an unlikely event, if the consumer does not switch off the non-
essential loads to reduce it to within the limit, supply to the load
is automatically disconnected after 5 cycles of interruption.
The supply from mains to the load can be restored only after
pressing the Reset button present in the front of TPN ACCL.
3. When Mains supply is restored
As soon as the main supply restores, the load is automatically
transferred to the mains supply after a delay of 2-4 sec.
With AGS, TPN ACCL itself generates the signal to automatically
stop the generator
Technical Specications
Standard Conformity IEC 60947-6-1
No. of Poles 3P+N
Rated current (In)
40A/63A/100A on mains,
10-100A on generator
Rated voltage (Ue) 415 / 220 Vac
Rated frequency 50 Hz
Transfer Time 8-12 sec
Restoring Time 2-4 sec
Rated Impulse Voltage
(Uimp)
6kV
Utilization Category AC 31A
Class of Equipment PC
Environment B
Indication
Mains, Generator, Load, Overload
(R,Y,B), mode of operation
(auto/manual)
Pollution Degree II
Conditional Short Circuit
Current
5kA
Ambient Temp. - 5 to + 55 C
Electrical Life 6000 operations
Mounting Surface mounting
Mounting Position Vertical
Terminal Capacity 16 mm
2
/

35 mm
2
Duty Uninterrupted
Weight 4.5 Kg / 9.4 Kg
Dimensions
260 x 243 x 115 mm
3
260 x 243 x 150 mm
3
383 x 333 x 150 mm
3
Main supply
MCB/RCCB
Load
Generator
L N
SCPD 2
R Y B N
SCPD 1
Auto GEN start control unit
MAINS LOAD IGN GEN
R Y B N R Y B N L N X1 X2
ACCL
ACCL TPN/TPN Wiring Arrangement during Installation
Main supply
MCB/RCCB
Load
Generator
R Y B N
SCPD 2
R Y B N
SCPD 1
Auto GEN start control unit
MAINS LOAD IGN GEN
R Y B N R Y B N R Y B N X1 X2
* SCPD can be - 40A MCB or fuse for 40A TPN ACCL
- 63A MCB or fuse for 63A TPN ACCL
- 100A MCB or fuse for 100A TPN ACCL
* SCPD can be - 40A MCB or fuse for 40A TPN ACCL
- 63A MCB or fuse for 63A TPN ACCL
- 100A MCB or fuse for 100A TPN ACCL
In TPN/SPN, the ACCL will restrict the load if the cumulative current of all the 3 phases (ie R+Y+B) exceeds rated generator current.
In TPN/TPN, the ACCL will restrict the load if the current in any of the phase (ie R or Y or B) exceeds rated generator current.
ACCL TPN/SPN Wiring Arrangement during Installation
ACCL
Features Advantage of Havells TPN ACCL Other Competitor Products
Mode Selection
can be operated in two different modes ie
automatic or manual as per customer requirement
not provided
Separate LED indication for individual
overloaded phase
customer immediately comes to know the
overloaded phase & can easily reduce the load
running on that phase
not available
Local reset facility
reset button provided, so no extra switch required
for restoring supply
extra switching device required for restoring
supply
Rated impluse voltage 6kV not mentioned
Pre-trip LED indication under overload
condition
provided not provided
Standard conformity as per IEC 60947-6-1 no marking on the product
Conditional short circuit Current 5kA not mentioned
Operating range 150 - 415 Vac 150 - 360 Vac
Automatic gen ON/OFF available (on special demand) not available
Feature Benets of Havells TPN ACCL
Dimension (in mm)
Side Front
B
A
C
D E
Rating A B C D E
40A TPN ACCL 115 243 205 224 260
63A TPN ACCL 150 243 205 224 260
100A TPN ACCL 150 333 293 337 383
S
W
I
/
Z
H
D
L
E
0
0
0
1
5
/
S
E
P
1
1
/
A
P
R
1
2
Havells India Ltd.
Corp Ofce: QRG Towers, 2D, Sector-126, Expressway, Noida-201304 (U.P), Ph. +91-120-4771000,
Email: marketing@havells.com, www.havells.com Consumer Care No.: 1800 11 0303 (Tollfree),
011-4166 0303 (Landline), 1800 103 1313 (All Connections)
Join us on Facebook at www.facebook.com/havells and share your ways to save the planet!
TPN ACCL
TPN ACCL (TPN/SPN)
(Automatic Source Changeover with Current Limiter)
TPN ACCL (TPN/TPN)
(Automatic Source Changeover with Current Limiter)
Gen Rating Description Cat. No. Cat. No. with GEN Start/Stop
20A 40A/20A TPN/SPN ACCL DHACOTN4020 DHACWTN4020
25A 40A/25A TPN/SPN ACCL DHACOTN4025 DHACWTN4025
30A 40A/30A TPN/SPN ACCL DHACOTN4030 DHACWTN4030
40A 40A/40A TPN/SPN ACCL DHACOTN4040 DHACWTN4040
20A 63A/20A TPN/SPN ACCL DHACOTN6320 DHACWTN6320
25A 63A/25A TPN/SPN ACCL DHACOTN6325 DHACWTN6325
30A 63A/30A TPN/SPN ACCL DHACOTN6330 DHACWTN6330
40A 63A/40A TPN/SPN ACCL DHACOTN6340 DHACWTN6340
Gen Rating Description Cat. No. Cat. No. with GEN Start/Stop
20A 40A/20A TPN/TPN ACCL DHACOTT4020 DHACWTT4020
25A 40A/25A TPN/TPN ACCL DHACOTT4025 DHACWTT4025
30A 40A/30A TPN/TPN ACCL DHACOTT4030 DHACWTT4030
40A 40A/40A TPN/TPN ACCL DHACOTT4040 DHACWTT4040
20A 63A/20A TPN/TPN ACCL DHACOTT6320 DHACWTT6320
25A 63A/25A TPN/TPN ACCL DHACOTT6325 DHACWTT6325
30A 63A/30A TPN/TPN ACCL DHACOTT6330 DHACWTT6330
40A 63A/40A TPN/TPN ACCL DHACOTT6340 DHACWTT6340