You are on page 1of 3

Project C922 - Expo Station

Subject Compression Pile Check


Designer Sunthar
Date
Concrete (f
cu
) = 40 N/mm2
Max allowable concrete stress, 0.25 fcu = 10.0 N/mm2 7.5 N/mm ,so
Designed concrete stress = 7.5 N/mm2
Factor of Safety = 2.5
Structural Capacity
[mm] 800
[kN] 14657
14657 kN OK!
Design Parameters: Skin friction, fs = 3.0 N 300 kPa
End bearing, fb = 100N 10 000 kPa
Geotechnical PTP-1
EGL 105.5 mRL
Soil Average Skin Friction Shaft length Skin Friction
Description SPT value fs = 3N l
shaft
f
s
x l
shaft
x pD
From To From To N kN/m [m] [kN]
105.50 105.50 0.00 0.00 Gravelly Silt 0 0 0.0 0
105.50 102.50 0.00 3.00 Gravelly Silt 0 0 3.0 0
102.50 99.50 3.00 6.00 Gravelly Sand 0 0 3.0 0
99.50 96.50 6.00 9.00 Gravelly Sand 0 0 3.0 0
96.50 93.50 9.00 12.00 Sandy Silt 0 0 3.0 0
93.50 90.50 12.00 15.00 Silty Sand 100 300 3.0 2262
90.50 87.50 15.00 18.00 Silty Sand 34 102 3.0 769
87.50 84.50 18.00 21.00 Silty Sand 56 168 3.0 1267
84.50 81.50 21.00 24.00 Silty Sand 39 117 3.0 882
81.50 79.50 24.00 26.00 Silty Sand 60 180 2.0 905
Drill depth from GL (m) 26.00
Cut-off Level (mRL) 105.500
Pile length from C.O.L (m) 0.0 m 26.00
Total Shaft Friction (kN), Qs 6085
End Bearing Capacity Bearing pressure (kPa) 6000
End bearing capacity (kN) 3016
Ultimate Geotechnical Capacity, Qn (kN) 9101
Criteria 1: (Shaft Friction + End Bearing)/2.5 3640
Criteria 2: (Shaft Friction/2.0) + (End Bearing/3.0) 4048
Criteria 3: (Shaft Friction/1.5) 4056
Working Load (Geotechnical) 3640
Test Load (3 x WL) 10921
capacity 800 mm
Soil Depth in mRL (m)
Soil Depth in mbgl
(m)
Pile Diameter
Pult = 0.40*fg*Ag+0.75*fy*As =
GEOTECHNICAL PILE LENGTH DESIGN
10/10/2011
Pile Size, D
Structural Capacity
use 16T40 (As=20106mm2)
PILE DEBOND UP TO 12.0m
PILE DEBOND UP TO 12.0m
GeoEng Consultants (S) Pte Ltd
29 Tai Seng Avenue #06-04
REF: Natural Cool Lifestyle Hub
DESIGNED BY: DATE: Singapore 534119
CHECKED BY: DATE: TEL: 6546 6318 FAX: 6546 6319
Compression Capacity Check
Compressive strength of concrete at 28 days f
cu
= 40 MPa
F
s
= 1
Pile Compression Ac' A
s(provided)
% (Qa)
st
Bar Spacing Remarks
Type (mm) Test Load (kN) (mm
2
) (mm
2
)
A
s(provided)
(kN) (mm c/c)
A 800 10921 482549 20106 4.00 16 T 40 14657 115 OK
7890 494801 7854 1.56 16 T 25 10626 118 OK
A
s(provided)
10/10/11
PROJ ECT: C922 Expo Station
Structural Capacity Checks
Sunthar
Dr. Ng
10/10/11
s
st
F
fyAs fcuAc
Qa
75 . 0 ' 4 . 0
) (
Depth Load Rebar Capacity
0 10921 14657
3 10921 14657
6 10921 14657
9 10921 14657
12 10921 14657
15 8659 14657
18 7890 14657
18 7890 10626
21 6623 10626
24 5741 10626
26 4836 10626
18
0
5
10
15
20
25
30
0 2000 4000 6000 8000 10000 12000 14000 16000 18000
D
e
p
t
h
Load
Pile Capacity
Geotechnical Capacity
Reinforcement Capacity
1
6
T
4
0
1
6
T
2
5