You are on page 1of 3

MONITOR

Geist Americas
1821 Yolande Ave
Lincoln, NE 68521 USA
1.800.432.3219 or
1.402.474.3400
www.geistglobal.com
Geist Europe
Unit 1, The Monarch Centre,
Ventrue Way,
Priorswood, Taunton,
Somerset, TA2 8DE UK
+44 (0) 1823 275100
www.geisteurope.com
Geist Asia
China
Tiley Plaza, Unit #2808,
No. 199 Haide 3 Road
Nanshan Shenzhen
Guangdong Province China
Postal Code: 518000
Tel: +86.755.86639505
www.geistglobal.com
Hong Kong
Tel: +852 90361927
Email: salesasia@geistglobal.com
www.geistglobal.com
Please note the information contained herein is for informational purposes only. Technical claims listed depend on a series of technical assumptions. Your
experience with these products may differ if you operate the products in an environment, which is different from the technical assumptions. Geist reserves
the right to modify these specifcations without prior notice. Geist makes no warranties, express or implied, on the information contained in this document.
Geist DCiM
2290 E Prospect Rd.
Fort Collins, CO 80525 USA
1.877.449.4150
www.geistglobal.com
Part Number: GRSO
Description:
The GRSO environmental monitor provides Web-based remote surveillance of temperature and any additional sensors
connected to the unit. It comes equipped with four digital and six analog sensor ports, an LCD display with scrolling
measurements, built-in audible alarm and three relay output ports. It is especially useful for monitoring environmental
conditions in critical applications such as data centers, server rooms, network closets or other critical facilities. The
relay outputs allow for automatic response upon alarm.
Easily view and log temperature, relative humidity, dew point, airfow, light, sound and external sensors connected to
the unit over the intranet or the Web. No software requiredsecurely access the graphical user interface from a Web
browser. Power adapter included. The GRSO supports both digital and analog sensors. GRSO supports the GIOE and
Remote Power Manager X2.
Product Highlights:
SNMP, Email, SMS and Voice Call* Alerts *Dialer Required for voice alerts.
The GRSO can trigger multiple alarms if temperature or additional sensors fall outside of specifed parameters via
SNMP (v1, v2c, v3), email and SMS messages (e-mail to SMS gateway). In addition, an external voice dialer with
backup battery can be triggered to call up to nine telephone numbers until the alert has been acknowledged.
Relay Outputs
The GRSO has three relay output ports that are controlled by the alarm conditions you select. The relays can trigger
an external auto-dialer, fashing lights, back-up a/c (via contactor) and/or other external devices. The three relays can
be programmed for any combination of sensor, high or low set points, as well as alarm conditions triggered by contact
closures. The relays can also be programmed to turn off when conditions return to normal, or programmed to remain
latched and require a manual reset. Additionally, you may energize or de-energize a relay any time over the Web
interface.

View Charts and Graphs on the Web

The GRSO allows active Web pages to display real-time readings and graphs of temperature, humidity and dew point
in addition to data logs in standard format (downloadable as XML or CSV fle). Graphing scales are fully adjustable.

MONITOR
Geist Americas
1821 Yolande Ave
Lincoln, NE 68521 USA
1.800.432.3219 or
1.402.474.3400
www.geistglobal.com
Geist Europe
Unit 1, The Monarch Centre,
Ventrue Way,
Priorswood, Taunton,
Somerset, TA2 8DE UK
+44 (0) 1823 275100
www.geisteurope.com
Geist Asia
China
Tiley Plaza, Unit #2808,
No. 199 Haide 3 Road
Nanshan Shenzhen
Guangdong Province China
Postal Code: 518000
Tel: +86.755.86639505
www.geistglobal.com
Hong Kong
Tel: +852 90361927
Email: salesasia@geistglobal.com
www.geistglobal.com
Please note the information contained herein is for informational purposes only. Technical claims listed depend on a series of technical assumptions. Your
experience with these products may differ if you operate the products in an environment, which is different from the technical assumptions. Geist reserves
the right to modify these specifcations without prior notice. Geist makes no warranties, express or implied, on the information contained in this document.
Geist DCiM
2290 E Prospect Rd.
Fort Collins, CO 80525 USA
1.877.449.4150
www.geistglobal.com
Interface Network IP Cameras

The Web page interfaces up to four IP cameras (not included), allowing you a quick view of remote conditionsespecially
useful in the event of an alarm.

No Software Required

The GRSO is simple to install and use, requiring no special software other than a standard Web browser. The GRSO
connects to an Ethernet network with a standard RJ45 connector and sends data in standard TCP/IP packets. It is easily
confgured with a simple menu using a Web browser and can be password protected with three access account level
types: Administrator, Control, and View Only. Users can securely access the monitor by entering its IP address.
Part Number: GRSO
Specifcations:
On-board Sensors:
Built-in Sensors
Temperature: -22 to 185 F (-30 to 85 C), +/- 0.5 C
Output Relays
Three SPDT dry-contact relays
Max switching capacity: 60V, 30W
Connectors: three screw terminals per relay
Three Relay Status LEDs (bi-color, green=on, red=off)
Remote Sensor Support
Digital sensor: four ports (supports 16 sensors, 600ft maximum aggregate length)
Analog sensor: six inputs (contact closure, 0-5 VDC)
Physical: 19 rack-mount, 1-U space
Power: 6VDC (supplied wall transformer)
Ethernet: 10 Mbps, RJ-45 receptacle
Two Network Status LEDs (Link and Activity)
Real-Time Clock (RTC) with power backup
Reset IP push-button: restores factory defaults
Horn Off push-button: silences alarm buzzer
Reboot push-button: reboots system
LCD Display: 2 lines x 8, back lit, cycling sensor values
Warranty: 3 years
MONITOR
Geist Americas
1821 Yolande Ave
Lincoln, NE 68521 USA
1.800.432.3219 or
1.402.474.3400
www.geistglobal.com
Geist Europe
Unit 1, The Monarch Centre,
Ventrue Way,
Priorswood, Taunton,
Somerset, TA2 8DE UK
+44 (0) 1823 275100
www.geisteurope.com
Geist Asia
China
Tiley Plaza, Unit #2808,
No. 199 Haide 3 Road
Nanshan Shenzhen
Guangdong Province China
Postal Code: 518000
Tel: +86.755.86639505
www.geistglobal.com
Hong Kong
Tel: +852 90361927
Email: salesasia@geistglobal.com
www.geistglobal.com
Please note the information contained herein is for informational purposes only. Technical claims listed depend on a series of technical assumptions. Your
experience with these products may differ if you operate the products in an environment, which is different from the technical assumptions. Geist reserves
the right to modify these specifcations without prior notice. Geist makes no warranties, express or implied, on the information contained in this document.
Geist DCiM
2290 E Prospect Rd.
Fort Collins, CO 80525 USA
1.877.449.4150
www.geistglobal.com
Software Features:
HTTP / HTTPS: Web access
Control relays through Web interface
Alarms: high/low values, multiple thresholds per sensor
Options to trigger relays or buzzer on alarm
ESMTP / POP3: email alerts, ESMTP / POP3 auth
SNMP (v1, v2c, v3): gets, traps and clears alerts, MIB
Paging: email to pager proxy
XML: meta-tagged sensor values, alarms, confg, relays
Syslog: send debug messages to Syslog server
Part Number: GRSO
Approvals:
RoHS
C-Tick
CE- EN55022 & EN55024
FCC- Class A, Part 15