Inductive Proximity Sensors

For Reliable Precision Feedback


21 Subject to change
Technical Data ............................................... 24-27
Applications.......................................................... 28
Ordering Information......................................... 29
Inductive Proximity Sensors Overview............ 30-31
DC Inductive Proximity Sensors
Cylindrical/Threaded Barrel Design
Switching Distances:
0.03 to 0.59 in / 0.8 to 15 mm, Type SIEN .......... 32-43
Threaded Barrel Design
Switching Distances:
0.16 and 0.28 in / 4 and 7 mm, Type SIEH ......... 44-45
Rectangular Design
Switching Distances:
0.08 and 0.59 in / 2 and 15 mm, Type SIES ....... 46-47
AC Inductive Proximity Sensors
Threaded Barrel Design
Switching Distances:
0.08 to 0.59 in / 2 to 15 mm, Type SIEW ............. 48-53
Accessories
Sockets/Cables for Sensors ....................... 54-56
Mounting Accessories ................................. 57-58
Subject to change 22
Inductive Proximity Sensors
Contents
Competitively-Priced
Inductive Proximity Sensors
for Reliable Precision Feedback
Festo low-cost, CE compliant inductive proximity sensors
feature PNP or NPN output, flush or non-flush mounting
styles, cylindrical or rectangular body designs, and
integral cable or plug connections. The cylindrical barrel
styles are available with 4 and 6.5 mm installation
diameters, and threaded sizes M5, M8, M12, M18, and
M30.
Included in the series, are AC and DC sensors, featuring
switching ranges from 0.03 to 0.59 in / 0.8 to 15 mm, and
switching frequencies up to 3 kHz.
Constructed of stainless steel or nickel plated brass,
these rugged sensors are fully sealed for reliable
operation in harsh environments. All models feature
integral LEDs, and built-in circuit protection.
magnetic
field
Inductive Proximity Sensors
Features
Subject to change 23
Low-Cost Non-contact Inductive Proximity Sensors for
Reliable, Precision Feedback in Automated Systems
I Built-in circuit protection
I PNP or NPN versions
I Switching frequencies
up to 3 kHz
I Versatile mounting options
I compliant
I Solid state, no moving parts
I Switching distances
from 0.03 to 0.59 in / 0.8 to 15 mm
I Low current consumption, <1 mA
Type SIEN-...
DC Proximity Sensors
Switching Distances:
0.03 to 0.59 in / 0.8 to 15 mm
I Integral 3-wire cable or
plug-in connections
I Installation Diameters:
4 mm, 6.5 mm
Thread sizes: M5, M8,
M12, M18, M30
pages 32-43
Type SIEH-...
DC Proximity Sensors
Switching Distances:
0.16 and 0.28 in / 4 and 7 mm
I Integral 3-wire cable or
plug-in connections
I Thread sizes: M12, M18
pages 44-45
Type SIEW-...
AC Proximity Sensors
Switching Distances:
0.08 to 0.59 in / 2 to 15 mm
I Integral 2-wire cable or
plug-in connections
I Thread sizes: M12,
M18, M30
pages 48-53
Type SIES-...
DC Proximity Sensors
Switching Distances:
0.08 and 0.59 in / 2 and 15 mm
I Rectangular Design
I Integral 3-wire cable or
plug-in connections
pages 46-47
Integral LED
Flush or non-flush mounting Plug connection or
integral polyurethane cable
Optional straight
or angle plug-in
sockets
Rugged high grade steel or
nickel-plated brass barrel
Installation Diameters:
4 and 6.5 mm
Threaded barrels:
M5, M8, M12, M18, M30
Inductive Proximity Sensors
Technical Data
24
Inductive Sensor
Inductive sensors are signal generators
that, without contact, detect the presence
of metallic workpieces or moving parts in
automated machinery and processes,
and convert the detected motion into an
electronic signal.
Sensors of this type have the following
characteristics:
1. Inductive sensors detect electrically
conductive metallic objects which pass
through or rest in the magnetic field of
the high-frequency oscillator.
2. The inductive sensor functions without
contacting the object to be detected.
3. Inducti ve sensors do not requi re
mechanical sensing attachments, such
as conventional rollers, pins or lever
arms.
4. The switching function is achieved
electronically.
The inductive sensor offers the following
advantages:
no mechanical wear, therefore long
service life.
no failure caused by contaminated,
burned or wet contacts.
no contact can bounce, therefore no
false signals.
high switching frequency to 3000 Hz.
not affected by vibrations.
optional mounting positions.
fully encapsulated, therefore high
protection class.
Operating Principles
When a metallic object passes by the active sensing surface (blue) of the sensor
within the specified sensing distance, an electric signal is produced.
Sensing Distance
Nominal Switching Distance Sn:
The characteristic sensing distance without regard to deviations in temperature,
voltage or manufacturing tolerances.
Actual Switching Distance Sr:
The actual sensing distance is determined at rated line voltage and an ambient
temperature of 293 K (about 68 F / 20 C). Maximum permissible deviation is
10% of the nominal sensing distance.
Useful Switching Distance Su:
The useful sensing distance within a predetermined voltage and temperature
range. Maximum permissible deviation is 10% of the actual sensing distance.
Working Switching Distance Sa:
The sensing distance at which the sensor operates within the permissible operat-
ing conditions. Sa is between 0 and the smallest useful sensing distance (Su).
(Ref. 8.1/2-1) (97/98) Subject to change
Measuring Plate 37 Steel
Active Area
Sensor
H = Hysteresis
4
2
1
Measuring Plate 37 Steel
Active Area
Sensing Distance
3
2
1
Turns On
Turns Off
Inductive Proximity Sensors
Technical Data
25 Subject to change (Ref. 8.1/2-2) (97/98)
Reproducibility R:
Reproduci bi l i ty R descri bes the re-
peatable accuracy of switching points
over an 8-hour period at room temperature
and a voltage with a maximum deviation of
5% of the nominal voltage.
Switching Hysteresis H:
Hysteresis is the difference between the
swi tch-on poi nt as the test pl ate
approaches the active surface of the
sensor and the switch-off point when it is
removed. It is measured in inches or
millimeters.
Y = Distance to the SIE... Sensor
X = Direction of Movement
A = Switch-on
B = Switch Point
H = Hysteresis
Line Voltage Field UB:
DC sensors rated for 24 VDC may be used within an operating range of 10 to
30 VDC.
AC sensors rated for 230 VAC may be used with operating voltages between
20 to 265 VAC.
At voltages below the minimum rated, the sensor will not work properly. At
voltages above the maximum rated, the sensor will be damaged.
Allowable Residual Ripple UW:
Per DIN 41755 residual ripple is the maximum permissible AC voltage (peak-
to-peak) which may be superimposed on the switching or operating voltage.
For the inductive reed switch a residual ripple of 10% within the operating
voltage range is allowable.
Limitations:
Operating Frequency:
The operating frequency for AC sensors is between 45 Hz and 65 Hz.
Idle Current I
O:
Idle current is sensor current without the load.
Rated Output Current Ie:
Rated output current is the maximum current through the load, with the sensor
in continuous operation.
Exceeding this current destroys sensors without short protection (e.g., AC
sensors).
DC sensors are generally protected against overload and shorts.
Note, however, that the sensor will not work properly if the short- protection
threshold is exceeded.
Minimum Load Current I
m:
The minimum load current is the smallest current that must flow to ensure
proper operation of the sensor.
Minimum load current is 0 mA with 3-wire DC designs and 5mA with 2-wire AC
designs.
Active Surface
Standing DC Voltage
Standing DC Voltage
Inductive Proximity Sensors
Technical Data
26
Determining Sensing
Frequency
Sensi ng frequency i s determi ned i n
accordance with standard EN 60947-5-2.
Measurement i s conducted at rated
voltage and ambient temperature. The
minimum values of the sensing frequency
which vary with nominal sensing distance
and design, are listed in the standard.
Sensing Frequency
Correction Factor
Pulse - Pause Relationship
Instantaneous Current Ik:
The instantaneous current is the maximum current that can flow for a given time
without damaging the sensor.
The instantaneous current is listed for AC sensors. This current is allowable for
20 ms each second.
DC sensors are short-circuit and overload protected, so that the maximum output
current is limited.
Voltage Drop Ud:
The voltage drop across the closed switch is not 0 V.
The voltage drop is the difference between line voltage and the voltage delivered
to the load at the sensor output. The voltage drop over the closed switch is less
than 3.2 VDC with 3-lead DC switches. With two-lead AC sensors the voltage
drop is less than 6 VAC.
Residual Current Ir:
The residual current through the open switch is not 0 mA.
The residual current flows through the open switch and the associated load.
With DC designs residual current is negligible.
With AC 2-wire designs, the residual current is less than 1.5 mA.
Sensing Frequency f:
The sensing frequency is the number of switching signals per second. The
sensing frequency is measured at a pulse-pause relationship of the dampening
mechanism of 1: 2.
At other pulse-pause relationships, the maximum sensing frequency decreases.
Ambient Temperature Ta:
Defines the minimum and maximum ambient temperature at which the sensor
functions properly and the actual sensing distance varies within the range of the
useful sensing distance. Operating outside the specified temperature range can
cause sensor failure.
Short Circuit Proof:
DC sensors are protected against short circuits and overloads.
The output begins to pulsate if the short circuit protection threshold value is
exceeded.
Polarity Protection:
The internal polarity protection ensures that the sensor will not be damaged if the
leads are incorrectly connected.
EMI-Measurement (Electro-Magnetic Compatibility):
EMI signifies that the sensor is protected against noise in industrial environments
and that the electro-magnetic emission of the sensor itself is limited to designed
values.
The inductive sensors conform to EN 60947-5-2 and carry the CE-certification in
accordance with EC-guideline 89/ 336/ EEC.
Protection Level:
The protection level conforms to DIN of 40050, Test Specification IP 67.
Insulation Specifications:
Basis is product standard EN 60947-5-2
Insulation properties were determined by the following tests:
1. Sine-waveform voltage with operating frequency (= insulation-test voltage)
2. Pulse voltage to IECS 255-5 (1 kV, 1.2/ 50 s, 500 ohm, 0.5 J).
(Ref. 8.1/2-3) (97/98) Subject to change
Sensor
Measuring Plates
2
1
Inductive Proximity Sensors
Technical Data
27 Subject to change (Ref. 8.1/2-4) (97/98)
Shock and
Vibration Specifications
Shock
Wave form: Half sine wave
Acceleration: 30 g
Duration: 18 ms
Vibration
Frequency range: 10 to 55 Hz
Oscillation amplitude: 0.04 in/1 mm
Cycle: 5 minutes
Durati on at resonance frequency or
55 Hz:
30 minutes in three directions (total 90
minutes)
Output Designs:
DC sensors with 3 wires switched either positive (PNP) or negative (NPN) to
the load.
AC sensors with 2 wires. The load to the inputs can be switched.
Logic Element Operation:
Normally open contact: When activated, the sensor provides current to the
load; when inactivated, the current flow is interrupted.
Normally closed contact: When activated, the sensor interrupts the current
flow; when inactivated, current flows to the load.
Bi-valent: Both normally open and normally closed outputs are available.
Mounting Styles:
Flush mounted sensors can be surrounded by metal except for the active face.
Non-flush mounted sensors require a metal-free zone around the active
surface.
Maximum Allowable Mounting Nut Torque:
M5 1.5 lb-ft / 2 Nm
M8 3.75 lb-ft / 5 Nm
M12 8.8 lb-ft / 12 Nm
M18 18.5 lb-ft / 25 Nm
M30 37 lb-ft / 50 Nm
Sensors without threads should be mounted with glue. The sensor may be
clamped with moderate pressure, preferably distributed over a large area.
Securing by drilling, e.g., using threaded pins, could easily damage the sensor.
Note:
Do not install the sensor as an end stop.
Inductive Proximity Sensors
Applications in Every Industry
28 Subject to change
For non-contact
proximity sensing
Non-contact actuation ap-
plied, for example, on pro-
tective guards, moving doors
and lifts
For end position
sensing
In a fixed stop sleeve e.g.
tool carriages of complex
machines
For positioning
High repeating accuracy e.g.
in clamping devices, in
manufacturing machines
For counting
High switching frequencies
e.g. on conveyor belts, on
sorting devices
For pulse recognition
Short switching times e.g. to
establish the number of
revolutions, to detect when a
machine has come to a
standstill
For determining
direction of motion
Idle return function e.g. to
determine the direction for
sorting of parts
For determining
direction of rotation
Fast detection of direction of
movement e.g. to determine
the direction of rotation for
advance and return strokes
For identification of
materials
Alternating magnetic field
e.g. for preparation and
sorting of materials
Inductive Proximity Sensors
Ordering Information
Subject to change 29
LED Indication
L = Operation status
2L = Power supply and
operation status
Connection Style
K = Integral cable
S = Plug connection M8 or M12
X = Screw-clip connection
Contact Type
S = Normally open contact (NO)
O = Normally closed contact (NC)
A = NO/NC contact
Output Type
P = PNP output
N = NPN output
Z = 2-wire cable
Mounting
B = Flush mounting
NB= Non-flush mounting
Installation Type (sensor body)
4 = Unthreaded, 4 mm dia
6.5 = Unthreaded, 6.5 mm dia
M5 = Metric M5 thread
M8 = Metric M8 thread
M12 = Metric M12 thread
M18 = Metric M18 thread
M30 = Metric M30 thread
Q = Rectangular housing
Q40 = Rectangular housing
V3 = Rectangular housing
Sensor Category
N = DC sensor with standard switching distances
H = DC sensor with extended switching distances
S = DC rectangular design sensor
W = AC sensor with standard switching distances
Function
SIE = Sensor, Inductive Proximity
S I E N

M 8 B

P O

All Festo products can be ordered from your local Festo Distributor or from Festo Regional Centers.
A Festo Order Number consists of a Part No. and a Type Code, as described here:
150391
Part No. Type
Part No.s are listed on
pages 30-31 and on sensor
description pages.
S L
Ordering Example
To order an inductive proximity sensor, flush mounted, PNP output with normally closed contacts,
M8 x 1 threaded, and plug connection, order:
Qty. Part No. Type
1 150391 SIEN-M8B-PO-S-L
To order a straight socket with M8 x 1 threaded connection and 7.6 ft / 2.5 m polyurethane cable, order:
Qty. Part No. Type
1 159421 SIM-M8-3GD-5-PU
30 (Ref. 8.1/1-1) (97/98) Subject to change
Inductive Proximity Sensors
Overview
Design S* Flush Mounted Non Flush Mounting
O* Order Number Order Number
Installation Diameter Part Number Type Part Number Type
/ Thread Size DC Proximity Sensor With Standard Switching Distances: 0.03 to 0.59 in / 0.8 to 15 mm
0.16 in / 4 mm with S 150362 SIEN-4B-PS-K-L
Cable 8.2 ft / 2.5 m O 150366 SIEN-4B-PO-K-L
page 32 S 150360 SIEN-4B-NS-K-L
O 150364 SIEN-4B-NO-K-L
0.16 in / 4 mm S 150363 SIEN-4B-PS-S-L
with Plug Connector O 150367 SIEN-4B-PO-S-L
page 32 S 150361 SIEN-4B-NS-S-L
O 150365 SIEN-4B-NO-S-L
0.26 in / 6.5 mm with S 150378 SIEN-6.5B-PS-K-L
Cable 8.2 ft / 2.5 m O 150382 SIEN-6.5B-PO-K-L
page 32 S 150376 SIEN-6.5B-NS-K-L
O 150380 SIEN-6.5B-NO-K-L
0.26 in / 6.5 mm S 150379 SIEN-6.5B-PS-S-L
with Plug Connector O 150383 SIEN-6.5B-PO-S-L
page 32 S 150377 SIEN-6.5B-NS-S-L
O 150381 SIEN-6.5B-NO-S-L
Thread Size M5 x 0.5 S 150370 SIEN-M5B-PS-K-L
with Cable 8.2 ft / 2.5 m O 150374 SIEN-M5B-PO-K-L
page 34 S 150368 SIEN-M5B-NS-K-L
O 150372 SIEN-M5B-NO-K-L
Thread Size M5 x 0.5 S 150371 SIEN-M5B-PS-S-L
with Plug Connector O 150375 SIEN-M5B-PO-S-L
page 34 S 150369 SIEN-M5B-NS-S-L
O 150373 SIEN-M5B-NO-S-L
Thread Size M8 x 1 S 150386 SIEN-M8B-PS-K-L 150394 SIEN-M8NB-PS-K-L
with Cable 8.2 ft / 2.5 m O 150390 SIEN-M8B-PO-K-L 150398 SIEN-M8NB-PO-K-L
page 36 S 150384 SIEN-M8B-NS-K-L 150392 SIEN-M8NB-NS-K-L
O 150388 SIEN-M8B-NO-K-L 150396 SIEN-M8NB-NO-K-L
Thread Size M8 x 1 S 150387 SIEN-M8B-PS-S-L 150395 SIEN-M8NB-PS-S-L
with Plug Connector O 150391 SIEN-M8B-PO-S-L 150399 SIEN-M8NB-PO-S-L
page 36 S 150385 SIEN-M8B-NS-S-L 150393 SIEN-M8NB-NS-S-L
O 150389 SIEN-M8B-NO-S-L 150397 SIEN-M8NB-NO-S-L
Thread Size M12 x 1 S 150402 SIEN-M12B-PS-K-L 150410 SIEN-M12NB-PS-K-L
with Cable 8.2 ft / 2.5 m O 150406 SIEN-M12B-PO-K-L 150414 SIEN-M12NB-PO-K-L
page 38 S 150400 SIEN-M12B-NS-K-L 150408 SIEN-M12NB-NS-K-L
O 150404 SIEN-M12B-NO-K-L 150412 SIEN-M12NB-NO-K-L
Thread Size M12 x 1 S 150403 SIEN-M12B-PS-S-L 150411 SIEN-M12NB-PS-S-L
with Plug Connector O 150407 SIEN-M12B-PO-S-L 150415 SIEN-M12NB-PO-S-L
page 38 S 150401 SIEN-M12B-NS-S-L 150409 SIEN-M12NB-NS-S-L
O 150405 SIEN-M12B-NO-S-L 150413 SIEN-M12NB-NO-S-L
Thread Size M18 x 1 S 150418 SIEN-M18B-PS-K-L 150426 SIEN-M18NB-PS-K-L
with Cable 8.2 ft / 2.5 m O 150422 SIEN-M18B-PO-K-L 150430 SIEN-M18NB-PO-K-L
page 40 S 150416 SIEN-M18B-NS-K-L 150424 SIEN-M18NB-NS-K-L
O 150420 SIEN-M18B-NO-K-L 150428 SIEN-M18NB-NO-K-L
Thread Size M18 x 1 S 150419 SIEN-M18B-PS-S-L 150427 SIEN-M18NB-PS-S-L
with Plug Connector O 150423 SIEN-M18B-PO-S-L 150431 SIEN-M18NB-PO-S-L
page 40 S 150417 SIEN-M18B-NS-S-L 150425 SIEN-M18NB-NS-S-L
O 150421 SIEN-M18B-NO-S-L 150429 SIEN-M18NB-NO-S-L
Thread Size M30 x 1.5 S 150434 SIEN-M30B-PS-K-L 150442 SIEN-M30NB-PS-K-L
with Cable 8.2 ft / 2.5 m O 150438 SIEN-M30B-PO-K-L 150446 SIEN-M30NB-PO-K-L
page 42 S 150432 SIEN-M30B-NS-K-L 150440 SIEN-M30NB-NS-K-L
O 150436 SIEN-M30B-NO-K-L 150444 SIEN-M30NB-NO-K-L
Thread Size M30 x 1.5 S 150435 SIEN-M30B-PS-S-L 150443 SIEN-M30NB-PS-S-L
with Plug Connector O 150439 SIEN-M30B-PO-S-L 150447 SIEN-M30NB-PO-S-L
page 42 S 150433 SIEN-M30B-NS-S-L 150441 SIEN-M30NB-NS-S-L
O 150437 SIEN-M30B-NO-S-L 150445 SIEN-M30NB-NO-S-L
S* = Normally open contact PS = PNP-Output, normally open contact NS = NPN-Output, normally open contact
O* = Normally closed contact PO = PNP-Output, normally closed contact NO = NPN-Output, normally closed contact
SIEN-M8B-ZS-K-L
SIEN-M8B-ZS-S-L
SIEN-M12B-NS-K-L
SIEN-M12B-NS-S-L
SIEN-M18B-NS-K-L
SIEN-M18B-NS-S-L
SIEN-M30B-NS-K-L
SIEN-M30B-NS-S-L
SIEN-M8NB-ZS-K-L
SIEN-M8NB-ZS-S-L
SIEN-M12NB-NS-K-L
SIEN-M12NB-NS-S-L
SIEN-M18NB-NS-K-L
SIEN-M18NB-NS-S-L
SIEW -M30NB-ZS-K-L
SIEW -M30NB-ZS-S-L
31 Subject to change (Ref. 8.1/1-2) (97/98)
Inductive Proximity Sensors
Overview
Design S* Flush Mounted Non Flush Mounting
O* Order Number Order Number
A* Part Number Type Part Number Type
DC Proximity Sensor With Extended Switching Distances: 0.16 and 0.28 in / 4 and 7 mm
Thread Size M12 x 1 S 150450 SIEH-M12B-PS-K-L
with Cable 8.2 ft / 2.5 m O 150454 SIEH-M12B-PO-K-L
page 44 S 150448 SIEH-M12B-NS-K-L
O 150452 SIEH-M12B-NO-K-L
Thread Size M12 x 1 S 150451 SIEH-M12B-PS-S-L
with Plug Connector O 150455 SIEH-M12B-PO-S-L
page 44 S 150449 SIEH-M12B-NS-S-L
O 150453 SIEH-M12B-NO-S-L
Thread Size M18 x 1 S 150458 SIEH-M18B-PS-K-L
with Cable 8.2 ft / 2.5 m O 150462 SIEH-M18B-PO-K-L
page 44 S 150456 SIEH-M18B-NS-K-L
O 150460 SIEH-M18B-NO-K-L
Thread Size M18 x 1 S 150459 SIEH-M18B-PS-S-L
with Plug Connector O 150463 SIEH-M18B-PO-S-L
page 44 S 150457 SIEH-M18B-NS-S-L
O 150461 SIEH-M18B-NO-S-L
Design DC Proximity Sensor With Standard Switching Distances: 0.08 and 0.59 in / 2 and 15 mm
Special Design S 150488 SIES-QB-PS-K-L
with Cable 8.2 ft / 2.5 m O 150489 SIES-QB-PO-K-L
page 46
Special Design S 150491 SIES-V3B-PS-S-L
with Plug Connection
page 46 S 150490 SIES-V3B-NS-S-L
Special Design A 150492 SIES-Q40B-PA-X-2L
with Screw-Clip
Connection
page 46
Design AC Proximity Sensor With Standard Switching Distances: 0.08 to 0.59 in / 2 to 15 mm
Thread Size M12 x 1 S 150464 SIEW-M12B-ZS-K-L 150468 SIEW-M12NB-ZS-K-L
with Cable 8.2 ft / 2.5 m O 150466 SIEW-M12B-ZO-K-L 150470 SIEW-M12NB-ZO-K-L
page 48
Thread Size M12 x 1 S 150465 SIEW-M12B-ZS-S-L 150469 SIEW-M12NB-ZS-S-L
with Plug Connector O 150467 SIEW-M12B-ZO-S-L 150471 SIEW-M12NB-ZO-S-L
page 48
Thread Size M18 x 1 S 150472 SIEW-M18B-ZS-K-L 150476 SIEW-M18NB-ZS-K-L
with Cable 8.2 ft / 2.5 m O 150474 SIEW-M18B-ZO-K-L 150478 SIEW-M18NB-ZO-K-L
page 50
Thread Size M18 x 1 S 150473 SIEW-M18B-ZS-S-L 150477 SIEW-M18NB-ZS-S-L
with Plug Connector O 150475 SIEW-M18B-ZO-S-L 150479 SIEW-M18NB-ZO-S-L
page 50
Thread Size M30 x 1.5 S 150480 SIEW-M30B-ZS-K-L 150484 SIEW-M30NB-ZS-K-L
with Cable 8.2 ft / 2.5 m O 150482 SIEW-M30B-ZO-K-L 150486 SIEW-M30NB-ZO-K-L
page 52
Thread Size M30 x 1.5 S 150481 SIEW-M30B-ZS-S-L 150485 SIEW-M30NB-ZS-S-L
with Plug Connector O 150483 SIEW-M30B-ZO-S-L 150487 SIEW-M30NB-ZO-S-L
page 52
S* = Normally open contact PS = PNP-Output, normally open contact NS = NPN-Output, normally open contact
O* = Normally closed contact PO = PNP-Output, normally closed contact NO = NPN-Output, normally closed contact
A* = N.O. / N.C. PA = PNP-Output N.O. / N.C.
SIEN-M12B-NS-K-L
SIEN-M12B-NS-S-L
SIEN-M18B-NS-K-L
SIEN-M18B-NS-S-L
SIES-QB-PO-K-L
S I E S - Q 4 0 B - P A - X - 2 L
1 5 0 4 9 2 P N P N . O . + N . C .
SIEW-M12B-ZS-K-L
SIEW-M12B-ZS-S-L
SIEW-M18B-ZS-K-L
SIEW-M18B-ZS-S-L
SIEW-M30B-ZS-K-L
SIEW-M30B-ZS-S-L
SIEW-M12NB-ZS-K-L
SIEW-M12NB-ZS-S-L
SIEW-M18NB-ZS-K-L
SIEW-M18NB-ZS-K-L
SIEW-M30NB-ZS-K-L
SIEW-M30NB-ZS-S-L
32 (Ref. 8.1/10-1) (97/98) Subject to change
Inductive Proximity Sensors
Cylindrical Barrel Design 0.16 in / 4 mm and 0.26 in / 6.5,
Inductive Proximity Sensors
Direct Current, Inductive, with Integral
Protective Circuit and 1 yellow LED
Flush Mounted
0.16 in / 4 mm Installation Diameter
Type SIEN-4B-...
0.26 in / 6.5 mm Installation Diameter
Type SIEN-6.5B-...
When a metal l i c obj ect i s wi thi n the
switching distance of the active blue face
of the sensor, an electrical signal is
generated.
An integral yellow LED is on whenever a
signal is generated.
Accessories:
Socket with Cable, Type SIM-M8-...
See page 54.
Sensor Tester
158481 SM-TEST-1
The sensor tester is used for checking
the functioning of proximity sensors.
See page 245.
Type SIEN-4B-... Type SIEN-6.5B-...
With cable With plug With cable With plug
PNP-Output
Normally Open Contact Normally Closed Contact
With cable With plug With cable With plug
NPN-Output
Normally Open Contact Normally Closed Contact
With cable With plug With cable With plug
Color Codes
BK = Black
BN = Brown
BU = Blue
PNP
N.O. A2.381-1A(10.95)
Pin Allocation
for Models with Plug
Order Number PNP- w/Cable 150362 150366 150378 150382
Part No./Type Output SIEN-4B-PS-K-L SIEN-4B-PO-K-L SIEN-6.5B-PS-K-L SIEN-6.5B-PO-K-L
w/Plug 150363 150367 150379 150383
SIEN-4B-PS-S-L SIEN-4B-PO-S-L SIEN-6.5B-PS-S-L SIEN-6.5B-PO-S-L
NPN- w/Cable 150360 150364 150376 150380
Output SIEN-4B-NS-K-L SIEN-4B-NO-K-L SIEN-6.5B-NS-K-L SIEN-6.5B-NO-K-L
w/Plug 150361 150365 150377 150381
SIEN-4B-NS-S-L SIEN-4B-NO-S-L SIEN-6.5B-NS-S-L SIEN-6.5B-NO-S-L
Operation Normally open Normally closed Normally open Normally closed
Design Non-contact electrical signal generator
Mounting Flush mounting
Installation Diameter 0.16 in / 4 mm 0.26 in / 6.5 mm
Nominal Switching Distance Sn 0.03 in / 0.8 mm 0.059 in / 1.5 mm
Actual Switching Distance Sr 0.028 to 0.035 in / 0.72 to 0.88 mm 0.053 to 0.065 in / 1.35 to 1.65 mm
Useful Switching Distance Su 0.025 to 0.038 in / 0.64 to 0.96 mm 0.047 to 0.071 in / 1.20 to 1.80 mm
Working Switching Distance Sa 0.025 in / 0.64 mm 0.047 in / 1.20 mm
Reproducibility R 0.0016 in / 0.040 mm 0.003 in / 0.075 mm
Switching Hysteresis H 0.0004 to 0.0006 in / 0.010 to 0.16 mm 0.002 to 0.012 in / 0.045 to 0.30 mm
Line Voltage Range UB 10 to 30 VDC
Residual Ripple Range UW 10% UB
Open Circuit Current Io < = 10 mA (with LED) < = 1 mA (without LED); 9 mA typical with LED
Output Switching Current Ie 200 mA
Voltage Drop Ud < 2V
Residual Current Ir < 0.1 mA < 0.01 mA
Switching Frequency f 3000 Hz 1500 Hz
Ambient Temperature Ta -13 to +158F / -25 to +70C -13 to 185F / -25 to +85C
Short Circuit Protection Included, timed
Polarity Protection Included
Insulation Characteristics Sine-formed test voltage 500 V, Pulse voltage IEC 255-5 1 kV
Type of Protection IP 67
Housing Material High grade steel
Connector Information PUR-Cable 8.2 ft / 2.5 m long, Socket with cable SIM-M8-...
Weight 0.11 lb / 0.048 kg w/Cable 0.14 lb / 0.064 kg w/Cable
0.02 lb / 0.009 kg w/Plug 0.04 lb / 0.02 kg w/Plug
PNP
N.O. A2.381-1B(10.95)
PNP
N.C. A2.381-1C(10.95)
PNP
N.C. A2.381-1D(10.95)
NPN
N.O. A2.381-1E(10.95)
BK
BN
BU
NPN
N.O. A2.381-1F(10.95)
NPN
N.C. A2.381-1G(10.95)
NPN
N.C. A2.381-1H(10.95)
Output
A2.381-1I(10.95)
Inductive Proximity Sensors
Dimensions
33 Subject to change (Ref. 8.1/10-2) (97/98)
Multipliers For Nominal Nominal
Various Metals Switching Distance Switching Distance
Type SIEN-4B-... SIEN-6.5B-...
37 Stainless Steel 1.0 x Sn 1.0 x Sn
18/8 High Grade Stainless Steel 0.7 x Sn 0.8 x Sn
Brass 0.4 x Sn 0.5 x Sn
Aluminum 0.4 x Sn 0.4 x Sn
Copper 0.3 x Sn 0.2 x Sn
Mounting Diameter 0.16 in / 4 mm, Flush Mounting
Type SIEN-4B-...
With Cable With Plug Mounting Method
For Type SIEN-6.5B-...:
3-wire cable 8.2 ft / 2.5 m long
(3 x 0.25 mm
2
)
For Type SIEN-4B-...:
3-wire cable 8.2 ft / 2.5 m long
(3 x 0.14 mm
2
)
Cable for NPN models is black;
cable for PNP models is gray
Active area
1 yellow operating status indicator
4 yellow operating status indicators
Metal-free area
5
4
3
2
1
c
b
a
d
e
f
a
g
M
8
x
1
h i
j
5
2
Mounting Diameter 0.26 in / 6.5 mm, Flush Mounting
Type SIEN-6.5B-...
With Cable With Plug Mounting Method
l
k
m o
n
k
p
q
a
Dimensions
a 0.16 in / 4 mm
b 0.98 in / 25 mm
c 0.71 in / 18 mm
d 0.14 in / 3.5 mm
e 1.65 in / 42 mm
f 0.83 in / 21 mm
g 0.28 in / 7 mm
h 0.10 in / 2.5 mm
i 0.20 in / 5 mm
j 0.08 in / 2 mm
k 0.26 in / 6.5 mm
l 1.38 in / 35 mm
m 0.18 in / 4.5 mm
n 1.77 in / 45 mm
o 1.30 in / 33 mm
p 0.47 in / 12 mm
q 0.12 in / 3 mm
34 (Ref. 8.1/11-1) (97/98) Subject to change
Type SIEN-M5B-...
Flush Mounted
With cable With plug
Inductive Proximity Sensors
Threaded Barrel Design, M5 x 0.5,
Inductive Proximity Sensors
Direct Current, Inductive, with Integral
Protective Circuit and yellow LED
Flush Mounted
Threaded Size M5 x 0.5
Type SIEN-M5B-...
When a metallic object is within the
switching distance of the active blue face
of the sensor, an electrical signal is
generated.
An integral yellow LED is on whenever a
signal is generated.
Accessories:
Socket with Cable, Type SIM-M8-...
See page 54.
Sensor Tester
158481 SM-TEST-1
The sensor tester is used for checking
the functioning of proximity sensors.
See page 245.
PNP-Output
Normally Open Contact Normally Closed Contact
With cable With plug With cable With plug
NPN-Output
Normally Open Contact Normally Closed Contact
With cable With plug With cable With plug
Pin Allocation
for Models with Plug
Color Codes
BK = Black
BN = Brown
BU = Blue
Output
PNP
N.O.
PNP
N.O.
PNP
N.C.
PNP
N.C.
NPN
N.O.
BK
BN
BU
NPN
N.O.
NPN
N.C.
NPN
N.C.
Order Number PNP- w/Cable 150370 150374
Part No./Type Output SIEN-M5B-PS-K-L SIEN-M5B-PO-K-L
w/Plug 150371 150375
SIEN-M5B-PS-S-L SIEN-M5B-PO-S-L
NPN- w/Cable 150368 150372
Output SIEN-M5B-NS-K-L SIEN-M5B-NO-K-L
w/Plug 150369 150373
SIEN-M5B-NS-S-L SIEN-M5B-NO-S-L
Operation Normally open Normally closed
Design Non-contact electrical signal generator
Mounting Flush mounting
Installation Diameter M5 x 0.5 Threaded
Nominal Switching Distance Sn 0.03 in / 0.8 mm
Actual Switching Distance Sr 0.028 to 0.035 in / 0.72 to 0.88 mm
Useful Switching Distance Su 0.025 to 0.038 in / 0.64 to 0.96 mm
Working Switching Distance Sa 0.025 in / 0.64 mm
Reproducibility R 0.002 in / 0.04 mm
Switching Hysteresis H 0.0004 to 0.0063 in / 0.010 to 0.160 mm
Line Voltage Range UB 10 to 30 VDC
Residual Ripple Range UW 10% UB
Open Circuit Current Io < = 10 mA (with LED)
Output Switching Current Ie 200 mA
Voltage Drop Ud < = 2 V
Residual Current Ir < = 0.1 mA
Switching Frequency f 3000 Hz
Ambient Temperature Ta -13 to +158F / -25 to +70C
Short Circuit Protection Included, stepped
Polarity Protection Included
Insulation Characteristics Sine-formed test voltage 500 V, Pulse voltage IEC 255-5 1 kV
Type of Protection IP 67
Housing Material High grade steel
Connection Information PUR-Cable 8.2 ft / 2.5 m long, socket with cable SIM-M8-...
Weight 0.11 lb / 0.048 kg w/cable 0.02 lb / 0.009 kg w/plug
Inductive Proximity Sensors
Dimensions
35 Subject to change (Ref. 8.1/11-2) (97/98)
Multipliers For Nominal Switching
Various Metals Distance
Type SIEN-M5B-...
37 Stainless Steel 1.0 x S
n
18/8 High Grade Stainless Steel 0.7 x S
n
Brass 0.4 x S
n
Aluminum 0.4 x S
n
Copper 0.3 x S
n
Type SIEN-M5B-...
Cable Plug Mounting Method
3-wire cable 8.2 ft / 2.5 m long
(3 x 0.14 mm
2
)
Cable for NPN models is black;
cable for PNP models is gray
Active area
1 yellow operating status indicator
4 yellow operating status indicators
Metal-free area
= Wrench size in mm
5
4
3
2
1
a
b
c
d
e
f
g
h
d i
j
5
2
Dimensions
a 0.98 in / 25 mm
b 0.79 in / 20 mm
c 0.71 in / 18 mm
d 0.10 in / 2.5 mm
e 0.14 in / 3.5 mm
f 1.65 in / 42 mm
g 0.91 in / 23 mm
h 0.28 in / 7 mm
i 0.20 in / 5 mm
j 0.08 in / 2 mm
Inductive Proximity Sensors
Threaded Barrel Design, M8 x 1,
36 (Ref. 8.1/12-1) (97/98) Subject to change
Inductive Proximity Sensors
Direct Current, Inductive, with Integral
Protective Circuit and yellow LED
Flush Mounted
Thread Size M8 x 1
Type SIEN-M8B-...
Non Flush Mounted
Threaded Size M8 x 1
Type SIEN-M8NB-...
When a metal l i c obj ect i s wi thi n the
switching distance of the active blue face
of the sensor, an el ectri cal si gnal i s
generated.
An integral yellow LED is on whenever a
signal is generated.
Accessories:
Socket with Cable, Type SIM-M8-...
See page 54.
Mounting Block, Type SDA-8 x 1-B
See page 57.
Sensor Tester
158481 SM-TEST-1
The sensor tester is used for checking
the functioning of proximity sensors.
See page 245.
Type SIEN-M8B-... Type SIEN-M8NB-...
Flush Mounted Non Flush Mounting
With cable With plug With cable With plug
PNP-Output
Normally Open Contact Normally Closed Contact
With cable With plug With cable With plug
NPN-Output
Normally Open Contact Normally Closed Contact
With cable With plug With cable With plug
Pin Allocation
for Models with Plug
Color Codes
BK = Black
BN = Brown
BU = Blue
PNP
N.O.
PNP
N.O.
PNP
N.C.
PNP
N.C.
NPN
N.O.
BK
BN
BU
NPN
N.O.
NPN
N.C.
NPN
N.C.
Output
Order Number PNP- Cable 150386 150390 150394 150398
Part No./Type Output SIEN-M8B-PS-K-L SIEN-M8B-PO-K-L SIEN-M8NB-PS-K-L SIEN-M8NB-PO-K-L
Plug 150387 150391 150395 150399
SIEN-M8B-PS-S-L SIEN-M8B-PO-S-L SIEN-M8NB-PS-S-L SIEN-M8NB-PO-S-L
NPN- Cable 150384 150388 150392 150396
Output SIEN-M8B-NS-K-L SIEN-M8B-NO-K-L SIEN-M8NB-NS-K-L SIEN-M8NB-NO-K-L
Plug 150385 150389 150393 150397
SIEN-M8B-NS-S-L SIEN-M8B-NO-S-L SIEN-M8NB-NS-S-L SIEN-M8NB-NO-S-L
Operation Normally open Normally closed Normally open Normally closed
Design Non-contact electrical signal generator
Mounting Flush mounting Non flush mounting
Installation Diameter M8 x 1 Threaded
Nominal Switching Distance Sn 0.06 in / 1.5 mm 0.098 in / 2.5 mm
Actual Switching Distance Sr 0.053 to 0.065 in / 1.35 to 1.65 mm 0.088 to 0.108 in / 2.25 to 2.75 mm
Useful Switching Distance Su 0.047 to 0.071 in / 1.20 to 1.80 mm 0.079 to 0.118 in / 2.00 to 3.00 mm
Working Switching Distance Sa 0.047 in / 1.20 mm 0.079 in / 2.00 mm
Reproducibility R 0.003 in / 0.075 mm 0.005 mm / 0.125 mm
Switching Hysteresis H 0.002 to 0.012 in / 0.045 to 0.30 mm 0.003 to 0.020 in / 0.075 to 0.50 mm
Line Voltage Range UB 10 to 30 VDC
Residual Ripple Range Uw 10% UB
Open Circuit Current Io < = 1 mA (without LED), (9 mA typical with LED)
Output Switching Current Ie 200 mA
Voltage Drop Ud < = 3.2 V
Residual Current Ir < = 0.01 mA
Switching Frequency f 1500 Hz 900 Hz
Ambient Temperature Ta -13 to +180F / -25 to +85C
Short Circuit Protection Included, stepped
Polarity Protection Included
Insulation Characteristics Sine-formed test voltage 500 V, Pulse voltage IEC 255-5 1 kV
Type of Protection IP 67
Housing Material High grade steel
Connection Information PUR-Cable 8.2 ft / 2.5 m long, socket with cable SIM-M8-...
Weight 0.13 lb / 0.06 kg w/cable 0.04 lb / 0.02 kg w/plug
3-wire cable 8.2 ft / 2.5 m long
(3 x 0.25 mm
2
)
Cable for NPN models is black;
cable for PNP models is gray
Active area
1 yellow operating status indicator
4 yellow operating status indicators
Metal-free area
= Wrench size in mm
5
4
3
2
1
37 Subject to change (Ref. 8.1/12-1) (97/98)
Multipliers For Nominal Switching Nominal Switching
Various Metals Distance Distance
Type SIEN-M8B-... SIEN-M8NB-...
37 Stainless Steel 1.0 x Sn 1.0 x Sn
18/8 High Grade Stainless Steel 0.8 x Sn 0.7 x Sn
Brass 0.5 x Sn 0.4 x Sn
Aluminum 0.4 x Sn 0.4 x Sn
Copper 0.2 x Sn 0.3 x Sn
Dimensions
a 1.38 in / 35 mm
b 0.16 in / 4 mm
c 0.18 in / 4.5 mm
d 1.77 in / 45 mm
e 1.30 in / 33 mm
f 0.47 in / 12 mm
g 0.12 in / 3 mm
h 0.43 in / 11 mm
i 0.39 in / 10 mm
j 0.22 in / 5.6 mm
k 0.24 in / 6 mm
l 0.22 in / 5.5 mm
Inductive Proximity Sensors
Dimensions
Threaded M8 x 1, Flush Mounted
Type SIEN-M8B-...
Cable Plug Mounting Method
a
b
c
d
e
b
b f
g
Threaded M8 x 1, Non Flush Mounting
Type SIEN-M8NB-...
Cable Plug Mounting Method
a
b b
c
b b
e
d h i
j
k
l
38 (Ref. 8.1/13-1) (97/98) Subject to change
Inductive Proximity Sensors
Threaded Barrel Design, M12 x 1,
Inductive Proximity Sensors
Direct Current, Inductive, with Integral
Protective Circuit and yellow LED
Flush Mounted
Threaded Size M12 x 1
Type SIEN-M12B-...
Non Flush Mounted
Threaded Size M12 x 1
Type SIEN-M12NB-...
When a metal l i c obj ect i s wi thi n the
switching gap of the active blue face of the
sensor, an electrical signal is generated.
An integral yellow LED is on whenever a
signal is generated.
Accessories:
Socket with Cable, Type SIM-M12-...
See page 54.
Mounting Block, Type SDA-12 x 1-B
See page 57.
Foot Mount, Type HBN-8/10 x 1
See page 58.
Sensor Tester
158481 SM-TEST-1
The sensor tester is used for checking the
functioning of proximity sensors.
See page 245.
Order Number PNP- w/Cable 150402 150406 150410 150414
Part No./Type Output SIEN-M12B-PS-K-L SIEN-M12B-PO-K-L SIEN-M12NB-PS-K-L SIEN-M12NB-PO-K-L
w/Plug 150403 150407 150411 150415
SIEN-M12B-PS-S-L SIEN-M12B-PO-S-L SIEN-M12NB-PS-S-L SIEN-M12NB-PO-S-L
NPN- w/Cable 150400 150404 150408 150412
Output SIEN-M12B-NS-K-L SIEN-M12B-NO-K-L SIEN-M12NB-NS-K-L SIEN-M12NB-NO-K-L
w/Plug 150401 150405 150409 150413
SIEN-M12B-NS-S-L SIEN-M12B-NO-S-L SIEN-M12NB-NS-S-L SIEN-M12NB-NO-S-L
Operation Normally Open Normally Closed Normally Open Normally Closed
Design Non-contact electrical signal generator
Mounting Flush mounting Non flush mounting
Installation Diameter M12 x 1 Threaded
Nominal Switching Distance Sn 0.08 in / 2 mm 0.16 in / 4 mm
Actual Switching Distance Sr 0.070 to 0.087 in / 1.80 to 2.20 mm 0.142 to 0.173 in / 3.60 to 4.40 mm
Useful Switching Distance Su 0.063 to 0.094 in / 1.60 to 2.40 mm 0.126 to 0.189 in / 3.20 to 4.80 mm
Working Switching Distance Sa 0.063 in / 1.60 mm 0.126 in / 3.20 mm
Reproducibility R 0.004 in / 0.10 mm 0.008 in / 0.20 mm
Switching Hysteresis H 0.002 to 0.016 in / 0.06 to 0.40 mm 0.005 to 0.031 in / 0.12 to 0.80 mm
Line Voltage Range UB 10 to 30 VDC
Residual Ripple Range UW 10% UB
Open Circuit Current Io < = 1 mA (without LED), (9 mA typical with LED)
Output Switching Current Ie 200 mA
Voltage Drop Ud < = 3.2 V
Residual Current Ir < = 0.01 mA
Switching Frequency f 1200 Hz 800 Hz
Ambient Temperature Ta -13 to +185F / -25 to +85C
Short Circuit Protection Included, timed
Insulation Characteristics Sine-formed test voltage 500 V, Pulse voltage IEC 255-5 1 kV
Type of Protection IP 67
Housing Material Nickel-plated brass
Connector Information PUR Cable 8.2 ft / 2.5 m long, Socket with cable SIM-M12-...
Weight 0.18 lb / 0.08 kg w/Cable 0.07 lb / 0.03 kg w/Plug
PNP-Output
Normally Open Contact Normally Closed Contact
With cable With plug With cable With plug
NPN-Output
Normally Open Contact Normally Closed Contact
With cable With plug With cable With plug
Pin Allocation
for Models with Plug
Color Codes
BK = Black
BN = Brown
BU = Blue
PNP
N.O.
PNP
N.O.
PNP
N.C.
PNP
N.C.
NPN
N.O.
BK
BN
BU
NPN
N.O.
NPN
N.C.
NPN
N.C.
Output
Normally open contact
Output
Normally closed contact
Type SIEN-M12B-... Type SIEN-M12B-...
Flush Mounted Non Flush Mounting
With cable With plug With cable With plug
39 Subject to change (Ref 2.381-8) (10.95)
Multipliers For Nominal Switching Nominal Switching
Various Metals Distance Distance
Type SIEN-M12B-... SIEN-M12NB-...
37 Stainless Steel 1.0 x Sn 1.0 x Sn
18/8 High Grade Stainless Steel 0.8 x Sn 0.7 x Sn
Brass 0.5 x Sn 0.4 x Sn
Aluminum 0.4 x Sn 0.4 x Sn
Copper 0.2 x Sn 0.3 x Sn
3-wire cable 8.2 ft / 2.5 m long
(3 x 0.25 mm
2
)
Cable for NPN models is black;
cable for PNP models is gray
Active area
1 yellow operating status indicator
4 yellow operating status indicators
Metal-free area
= Wrench size in mm
5
4
3
2
1
Dimensions
a 1.38 in / 35 mm
b 0.16 in / 4 mm
c 0.18 in / 4.5 mm
d 1.77 in / 45 mm
e 1.36 in / 34.5 mm
f 0.24 in / 6 mm
g 0.47 in / 12 mm
h 0.20 in / 5 mm
i 0.26 in / 6.5 mm
j 0.59 in / 15 mm
k 1.06 in / 27 mm
l 0.31 in / 8 mm
m 0.35 in / 9 mm
Inductive Proximity Sensors
Dimensions
Threaded M12 x 1, Flush Mounted
Type SIEN-M12B-...
Cable Plug Mounting Method
b
a
c
b
e
d f g
h
Threaded M12 x 1, Non Flush Mounting
Type SIEN-M12NB-...
Cable Plug Mounting Method
b
i
a
c
d
e
b
i
j k
l
m
l
Inductive Proximity Sensors
Threaded Barrel Design, M18 x 1,
40 (Ref. 8.1/14-1) (97/98) Subject to change
Type SIEN-M18B-... Type SIEN-M18B-...
Flush Mounted Non Flush Mounting
With cable With plug With cable With plug
PNP-Output
Normally Open Contact Normally Closed Contact
With cable With plug With cable With plug
NPN-Output
Normally Open Contact Normally Closed Contact
With cable With plug With cable With plug
Color Codes
BK = Black
BN = Brown
BU = Blue
PNP
N.O.
PNP
N.O.
PNP
N.C.
PNP
N.C.
NPN
N.O.
BK
BN
BU
NPN
N.O.
NPN
N.C.
NPN
N.C.
Order Number PNP- w/Cable 150418 150422 150426 150430
Part No./Type Output SIEN-M18B-PS-K-L SIEN-M18B-PO-K-L SIEN-M18NB-PS-K-L SIEN-M18NB-PO-K-L
w/Plug 150419 150423 150427 150431
SIEN-M18B-PS-S-L SIEN-M18B-PO-S-L SIEN-M18NB-PS-S-L SIEN-M18NB-PO-S-L
NPN- w/Cable 150416 150420 150424 150428
Output SIEN-M18B-NS-K-L SIEN-M18B-NO-K-L SIEN-M18NB-NS-K-L SIEN-M18NB-NO-K-L
w/Plug 150417 150421 150425 150429
SIEN-M18B-NS-S-L SIEN-M18B-NO-S-L SIEN-M18NB-NS-S-L SIEN-M18NB-NO-S-L
Operation Normally Open Normally Closed Normally Open Normally Closed
Design Non-contact electrical signal generator
Mounting Flush mounting Non flush mounting
Installation Diameter M18 x 1 Threaded
Nominal Switching Distance Sn 0.20 in / 5 mm 0.31 in / 8 mm
Actual Switching Distance Sr 0.177 to 0.217 in / 4.50 to 5.50 mm 0.283 to 0.346 in / 7.20 to 8.80 mm
Useful Switching Distance Su 0.157 to 0.236 in / 4.00 to 6.00 mm 0.256 to 0.382 in / 6.50 to 9.70 mm
Working Switching Distance Sa 0.157 in / 4.00 mm 0.256 in / 6.50 mm
Reproducibility R 0.006 in / 0.15 mm 0.008 in / 0.20 mm
Switching Hysteresis H 0.006 to 0.039 in / 0.15 to 1.00 mm 0.009 to 0.063 in / 0.24 to 1.60 mm
Line Voltage Range UB 10 to 30 VDC
Residual Ripple Range UW 10% UB
Open Circuit Current Io < = 1 mA (without LED), (9 mA typical with LED)
Output Switching Current Ie 200 mA
Voltage Drop Ud < = 3.2 V
Residual Current Ir < = 0.01 mA
Switching Frequency f 800 Hz 500 Hz
Ambient Temperature Ta -13 to +185F / -25 to +85C
Short Circuit Protection Included, timed
Insulation Characteristics Sine-formed test voltage 500 V, Pulse voltage IEC 255-5 1 kV
Type of Protection IP 67
Housing Material Nickel-plated brass
Connector Information PUR-Cable 8.2 ft / 2.5 m long, Socket with cable SIM-M12-...
Weight 0.26 lb / 0.12 kg w/Cable - 0.09 lb / 0.04 kg w/Plug
Pin Allocation
for Models with Plug
Output
Normally open contact
Output
Normally closed contact
Inductive Proximity Sensors
Direct Current, Inductive, with Integral
Protective Circuit and yellow LED
Flush Mounted
Threaded Size M18 x 1
Type SIEN-M18B-...
Non Flush Mounting
Threaded Size M18 x 1
Type SIEN-M18NB-...
When a metal l i c obj ect i s wi thi n the
switching gap of the active blue face of
the sensor, an el ectri cal si gnal i s
generated.
An integral yellow LED is on whenever a
signal is generated.
Accessories:
Socket with Cable, Type SIM-M12-...
See page 54.
Sensor Tester
158481 SM-TEST-1
The sensor tester is used for checking
the functioning of proximity sensors.
See page 245.
41 Subject to change (Ref. 8.1/14-2) (97/98)
3-wire cable 8.2 ft / 2.5 m long
(3 x 0.25 mm
2
)
Cable for NPN models is black;
cable for PNP models is gray
Active area
1 yellow operating status indicator
4 yellow operating status indicators
Metal-free area
= Wrench size in mm
5
4
3
2
1
Dimensions
a 1.38 in / 35 mm
b 0.16 in / 4 mm
c 0.18 in / 4.5 mm
d 1.77 in / 45 mm
e 1.36 in / 34.5 mm
f 1.22 in / 31 mm
g 0.43 in / 11 mm
h 0.83 in / 21 mm
i 0.39 in / 10 mm
j 0.41 in / 10.5 mm
k 0.79 in / 20 mm
l 1.10 in / 28 mm
m 0.59 in / 15 mm
Inductive Proximity Sensors
Dimensions
Threaded M18 x 1, Flush Mounted
Type SIEN-M18B-...
Cable Plug Mounting Method
c
b
a
b
f
e
d
g h
i
Threaded M18 x 1, Non Flush Mounting
Type SIEN-M18NB-...
Cable Plug Mounting Method
a
j
b
c
b j
f
e
d
k l
m
g
m
Multipliers For Nominal Nominal
Various Metals Switching Distance Switching Distance
Type SIEN-M18B-... SIEN-M18NB-...
37 Stainless Steel 1.0 x Sn 1.0 x Sn
18/8 High Grade Stainless Steel 0.7 x Sn 0.7 x Sn
Brass 0.4 x Sn 0.4 x Sn
Aluminum 0.4 x Sn 0.4 x Sn
Copper 0.3 x Sn 0.3 x Sn
Inductive Proximity Sensors
Threaded Barrel Design, M30 x 1.5,
42 (Ref. 8.1/15-1) (97/98) Subject to change
Order Number PNP- w/Cable 150434 150438 150442 150446
Part No./Type Output SIEN-M30B-PS-K-L SIEN-M30B-PO-K-L SIEN-M30NB-PS-K-L SIEN-M30NB-PO-K-L
w/Plug 150435 150439 150443 150447
SIEN-M30B-PS-S-L SIEN-M30B-PO-S-L SIEN-M30NB-PS-S-L SIEN-M30NB-PO-S-L
NPN- w/Cable 150432 150436 150440 150444
Output SIEN-M30B-NS-K-L SIEN-M30B-NO-K-L SIEN-M30NB-NS-K-L SIEN-M30NB-NO-K-L
w/Plug 150433 150437 150441 150445
SIEN-M30B-NS-S-L SIEN-M30B-NO-S-L SIEN-M30NB-NS-S-L SIEN-M30NB-NO-S-L
Operation Normally Open Normally Closed Normally Open Normally Closed
Design Non-contact electrical signal generator
Mounting Flush mounting Non flush mounting
Installation Diameter M30 x 1.5 Threaded
Nominal Switching Distance Sn 0.39 in / 10 mm 0.59 in / 15 mm
Actual Switching Distance Sr 0.354 to 0.433 in / 9.00 to 11.00 mm 0.531 to 0.649 in / 13.50 to 16.50 mm
Useful Switching Distance Su 0.315 to 0.472 in / 8.00 to 12.00 mm 0.480 to 0.717 in / 12.20 to 18.20 mm
Working Switching Distance Sa 0.315 in / 8.00 mm 0.480 in / 12.20 mm
Reproducibility R 0.012 in / 0.30 mm 0.016 in / 0.040 mm
Switching Hysteresis H 0.012 to 0.079 in / 0.30 to 2.00 mm 0.018 to 0.118 in / 0.45 to 3.00 mm
Line Voltage Range UB 10 to 30 VDC
Residual Ripple Range UW 10% UB
Open Circuit Current Io < 1 mA (without LED), (9mA typical with LED)
Output Switching Current Ie 200 mA
Voltage Drop Ud < 3.2 V
Residual Current Ir < 0.01 mA
Switching Frequency f 500 Hz 400 Hz
Ambient Temperature Ta -13 to 185F / -25 to +85C
Short Circuit Protection Included, timed
Polarity Protection Included
Insulation Characteristics Sine-formed test voltage 500 V, Pulse voltage IEC 255-5 1 kV
Type of Protection IP 67
Housing Material Nickel-plated brass
Connector Information PUR Cable 8.2 ft / 2.5 m long, Socket with cable SIM-M12-...
Weight 0.37 lb / 0.17 kg w/Cable - 0.22 lb / 0.1 kg w/Cable
Inductive Proximity Sensors
Direct Current, Inductive, with Integral
Protective Circuit and yellow LED
Flush Mounted
Threaded Size M30 x 1.5
Type SIEN-M30B-...
Non Flush Mounting
Threaded Size M30 x 1.5
Type SIEN-M30NB-...
When a metal l i c obj ect i s wi thi n the
switching distance of the active blue face
of the sensor, an electrical signal is
generated.
An integral yellow LED is on whenever a
signal is generated.
Accessories:
Socket with Cable, Type SIM-M12-...
See page 54.
Foot Mount, Type FV-32
See page 58.
Sensor Tester
158481 SM-TEST-1
The sensor tester is used for checking
the functioning of proximity sensors.
See page 245.
Type SIEN-M30B-... Type SIEN-M30NB-...
Flush Mounted Non Flush Mounting
With cable With plug With cable With plug
PNP-Output
Normally Open Contact Normally Closed Contact
With cable With plug With cable With plug
NPN-Output
Normally Open Contact Normally Closed Contact
With cable With plug With cable With plug
Color Codes
BK = Black
BN = Brown
BU = Blue
PNP
N.O.
PNP
N.O.
PNP
N.C.
PNP
N.C.
NPN
N.O.
BK
BN
BU
NPN
N.O.
NPN
N.C.
NPN
N.C.
Pin Allocation
for Models with Plug
Output
Normally open contact
Output
Normally closed contact
43 Subject to change (Ref. 8.1/15-2) (97/98)
Multipliers For Nominal Nominal
Various Metals Switching Distance Switching Distance
Type SIEN-M30B-... SIEN-M30NB-...
37 Stainless Steel 1.0 x Sn 1.0 x Sn
18/8 High Grade Stainless Steel 0.7 x Sn 0.7 x Sn
Brass 0.4 x Sn 0.4 x Sn
Aluminum 0.4 x Sn 0.4 x Sn
Copper 0.3 x Sn 0.3 x Sn
3-wire cable 8.2 ft / 2.5 m long
(3 x 0.25 mm
2
)
Cable for NPN models is black;
cable for PNP models is gray
Active area
1 yellow operating status indicator
4 yellow operating status indicators
Metal-free area
= Wrench size in mm
5
4
3
2
1
Dimensions
a 1.38 in / 35 mm
b 0.20 in / 5 mm
c 0.18 in / 4.5 mm
d 1.77 in / 45 mm
e 1.36 in / 34.5 mm
f 1.22 in / 31 mm
g 0.98 in / 25 mm
h 1.46 in / 37 mm
i 0.63 in / 16 mm
j 0.61 in / 15.5 mm
k 1.18 in / 30 mm
l 3.15 in / 80 mm
m 0.59 in / 15 mm
Inductive Proximity Sensors
Dimensions
Thread Size M30 x 1.5, Flush Mounted
Type SIEN-M30B-...
Cable Plug Mounting Method
c
b
a
b
f
e
d g h
i
Thread Size M30 x 1.5, Non Flush Mounting
Type SIEN-M30NB-...
Cable Plug Mounting Method
b
j
a
c b
f
e
d
j
k l
g
m
g
Inductive Proximity Sensors
Threaded Barrel Design, M12 x 1 and M18 x 1,
44 (Ref. 8.1/20-1) (97/98) Subject to change
Type SIEH-M12B-... Type SIEH-M18B-...
Flush Mounted Flush Mounted
With cable With plug With cable With plug
PNP-Output
Normally Open Contact Normally Closed Contact
With cable With plug With cable With plug
NPN-Output
Normally Open Contact Normally Closed Contact
With cable With plug With cable With plug
Color Codes
BK = Black
BN = Brown
BU = Blue
PNP
N.O.
PNP
N.O.
PNP
N.C.
PNP
N.C.
NPN
N.O.
BK
BN
BU
NPN
N.O.
NPN
N.C.
NPN
N.C.
Inductive Proximity Sensors
Direct Current, Inductive, with Integral
Protective Circuit and yellow LED
Flush Mounted
Thread Size M12 x 1
Type SIEH-M12B-...
Thread Size M18 x 1
Type SIEH-M18B-...
When a metal l i c obj ect i s wi thi n the
switching distance of the active blue face
of the sensor, an el ectri cal si gnal i s
generated.
An integral yellow LED is on whenever a
signal is generated.
Accessories:
Socket with Cable, Type SIM-M12-B
See page 54.
Mounting Block, Type SDA-12 x 1-B
See page 57.
Foot Mount, Type HBN-8/10 x 1
See page 58.
Sensor Tester
158481 SM-TEST-1
The sensor tester is used for checking
the functioning of proximity sensors.
See page 245.
Order Number PNP- w/Cable 150450 150454 150458 150462
Part No./Type Output SIEH-M12B-PS-K-L SIEH-M12B-PO-K-L SIEH-M18B-PS-K-L SIEH-M18B-PO-K-L
w/Plug 150451 150455 150459 150463
SIEH-M12B-PS-S-L SIEH-M12B-PO-S-L SIEH-M18B-PS-S-L SIEH-M18B-PO-S-L
NPN- w/Cable 150448 150452 150456 150460
Output SIEH-M12B-NS-K-L SIEH-M12B-NO-K-L SIEH-M18B-NS-K-L SIEH-M18B-NO-K-L
w/Plug 150449 150453 150457 150461
SIEH-M12B-NS-S-L SIEH-M12B-NO-S-L SIEH-M18B-NS-S-L SIEH-M18B-NO-S-L
Operation Normally Open Normally Closed Normally Open Normally Closed
Design Non-contact electrical signal generator
Mounting Flush mounting
Installation Diameter M12 x 1 Threaded M18 x 1 Threaded
Nominal Switching Distance Sn 0.16 in / 4 mm 0.28 in / 7 mm
Actual Switching Distance Sr 0.126 to 0.189 in / 3.20 to 4.80 mm 0.213 to 0.339 in / 5.40 to 8.60 mm
Useful Switching Distance Su 0.114 to 0.209 in / 2.90 to 5.30 mm 0.193 to 0.374 in / 4.90 to 9.50 mm
Working Switching Distance Sa 0.114 in / 2.90 mm 0.193 in / 4.90 mm
Reproducibility R 0.008 in / 0.20 mm 0.008 in / 0.20 mm
Switching Hysteresis H 0.005 to 0.031 in / 0.12 to 0.80 mm 0.006 to 0.068 in / 0.16 to 1.72 mm
Line Voltage Range UB 10 to 30 VDC
Residual Ripple Range UW 10% UB
Open Circuit Current Io < = 1 mA (without LED) (9mA typical with LED)
Output Switching Current Ie 200 mA
Voltage Drop Ud < 3.2 V
Residual Current Ir < 0.01 mA
Switching Frequency f 800 Hz 250 Hz
Ambient Temperature Ta -13 to 185F / -25 to +85C
Short Circuit Protection Included, timed
Polarity Protection Included
Insulation Characteristics Sine-formed test voltage 500 V, Pulse voltage IEC 255-5 1 kV
Type of Protection IP 67
Housing Material Nickel-plated brass
Connector Information PUR-Cable 8.2 ft / 2.5 m long, Socket with cable SIM-M12-...
Weight 0.18 lb / 0.08 kg w/Cable 0.26 lb / 0.12 kg w/Cable
0.07 lb / 0.03 kg w/Plug 0.09 lb / 0.04 kg w/Plug
Pin Allocation
for Models with Plug
Output
Normally open contact
Output
Normally closed contact
45 Subject to change (Ref. 8.1/20-2) (97/98)
Multipliers For Nominal Nominal
Various Metals Switching Distance Switching Distance
Type SIEH-M12B-... SIEH-M18B-...
37 Stainless Steel 1.0 x Sn 1.0 x Sn
18/8 High Grade Stainless Steel 0.9 x Sn 0.7 x Sn
Brass 0.6 x Sn 0.4 x Sn
Aluminum 0.5 x Sn 0.4 x Sn
Copper 0.4 x Sn 0.3 x Sn
3-wire cable 8.2 ft / 2.5 m long
(3 x 0.25 mm
2
)
Cable for NPN models is black;
cable for PNP models is gray
Active area
1 yellow operating status indicator
4 yellow operating status indicators
Metal-free area
= Wrench size in mm
5
4
3
2
1
Dimensions
a 1.38 in / 35 mm
b 0.16 in / 4 mm
c 0.18 in / 4.5 mm
d 1.77 in / 45 mm
e 1.36 in / 34.5 mm
f 0.63 in / 16 mm
g 0.55 in / 14 mm
h 0.31 in / 8 mm
i 0.79 in / 20 mm
j 1.18 in / 30 mm
k 1.22 in / 31 mm
Inductive Proximity Sensors
Dimensions
Thread Size M12 x 1, Flush Mounted
Type SIEH-M12B-...
Cable Plug Mounting Method
b
a
c
b
e
d
g f
h
Thread Size M18 x 1, Flush Mounted
Type SIEH-M18B-...
Cable Plug Mounting Method
b
a
c
b
k
e
d
i
i
j
Inductive Proximity Sensors
Rectangular Design Sensor,
46 (Ref. 8.1/30-1) (97/98) Subject to change
Order Number PNP Normally Open Contact Cable 150488 SIES-QB-PS-K-L
Part No./Type PNP Normally Closed Contact Cable 150489 SIES-QB-PO-K-L
PNP Normally Open Contact Plug 150491 SIES-V3B-PS-S-L
NPN Normally Open Contact Plug 150490 SIES-V3B-NS-S-L
PNP N.O. / N.C. 150492 SIES-Q40B-PA-X-2L
Design Non-contact electrical signal generator
Mounting Flush mounting is possible
Installation Through-hole in housing
Nominal Switching Distance Sn 0.08 in / 2 mm 0.59 in / 15 mm
Actual Switching Distance Sr 0.070 to 0.087 in / 1.80 to 2.20 mm 0.531 to 0.649 in / 13.50 to 16.50 mm
Useful Switching Distance Su 0.063 to 0.094 in / 1.60 to 2.40 mm 0.480 to 0.717 in / 12.20 to 18.20 mm
Working Switching Distance Sa 0.063 in / 1.60 mm 0.480 in / 12.20 mm
Reproducibility R 0.004 in / 0.10 mm 0.030 in / 0.75 mm
Switching Hysteresis H 0.002 to 0.016 in / 0.06 to 0.40 mm 0.018 to 0.12 in / 0.45 to 3.0 mm
Line Voltage Range UB 10 to 30 VDC
Residual Ripple Range UW 10% UB
Idle Current Io < = 1 mA (without LED) (9 mA typical with LED) < = 20 mA (with LED)
Output Switching Current Ie 300 mA 200 mA 300 mA
Voltage Drop Ud < = 3.2 V < = 3.5 V
Residual Current Ir < = 0.01 mA
Switching Frequency f 1200 Hz 100 Hz
Ambient Temperature Ta -13 to 185F / -25 to +85C
Short Circuit Protection Included, timed
Polarity Protection Included
Insulation Characteristics Sine-formed test voltage 500 V, Pulse voltage IEC 255-5 1 kV
Type of Protection IP 67
Housing Material Valox Diecast Zinc Crastin
Connection Information PUR Cable 8.2 ft / 2.5 m long Plug for SIM-M8-... Screw-clip connection
Weight 0.37 lb / 0.17 kg 0.26 lb / 0.12 kg 0.51 lb / 0.23 kg
Inductive Proximity Sensors
DC, Inductive, with internal protective
circuit and yellow LED
Flush-mounted
Type SIES-QB-...
SIES-V3B-...
SIES-Q40B-...
When a metal l i c obj ect i s wi thi n the
switching distance of the active blue face
of the sensor, an el ectri cal si gnal i s
generated.
SIES-QB, SIES-V3B-...
An integral yellow LED is on whenever a
signal is generated.
SIES-Q40B-...
An integral yellow LED is on whenever the
normally-open contact is activated.
Accessories:
Socket with Cable, Type SIM-M8-...
See page 54.
Mounting Bracket, Type HV-M5 for sensor,
Type SIES-V3B-...
See page 58.
Sensor Tester
158481 SM-TEST-1
The sensor tester is used for checking
the functioning of proximity sensors.
See page 245.
Type SIES-QB-... Type SIES-Q40B-...
With cable With clip-on connection
Type SIES-V3B-...
With plug
PNP-Output PNP-Output PNP-Output NPN-Output
Normally Normally Normally Normally
Open Contact Closed Contact Open Contact Open Contact
With cable With cable With plug With plug
Pin Allocation
for Models with Plug
Color Codes
BK = Black
BN = Brown
BU = Blue
PNP-Output
N.O. / N.C.
PNP
N.O.
PNP
N.C.
PNP
N.O.
1
3
4
NPN
N.O.
Output
Multipliers For Nominal
Various Metals Switching Distance
37 Stainless Steel 1.0 x Sn
18/8 High Grade Stainless Steel 0.9 x Sn
Brass 06 x Sn
Aluminum 0.5 x Sn
Copper 0.4 x Sn
Type SIES-QB-..., Cable Mounting Method
Inductive Proximity Sensors
Dimensions
Subject to change (Ref. 8.1/30-2) (97/98)
f
f
g
h
d
c
b
a
i j
e
k
h d
3-wire cable
8.2 ft / 2.5 m long
(3 x 0.25 mm
2
)
Active area
Yellow operating
status indicator
Center of Sensor
Metal-free area
5
4
3
2
1
Type SIES-V3B-..., Plug Mounting Method
m
l
d
n
c
o
p
q
r Active area
4 yellow operating
status indicators
Metal-free area
5
3
2
Type SIES-Q40B-..., Clip-on Connection Mounting Method
s
g
g q
z
u v
w
n
x y
g
t
q
aa bb
Multipliers For Nominal
Various Metals Switching Distance
37 Stainless Steel 1.0 x Sn
18/8 High Grade Stainless Steel 0.7 x Sn
Brass 0.4 x Sn
Aluminum 0.4 x Sn
Copper 0.3 x Sn
Power Indicator Green
Sensitive area is at the front when delivered.
Sensor head is adjustable in 5 positions.
Yellow operating status indicator
Metal-free area
5
3
2
1
k
h d
Dimensions
a 0.13 in / 3.2 mm
b 0.26 in / 6.5 mm
c 0.18 in / 4.5 mm
d 0.47 in / 12 mm
e 1.26 in / 32 mm
f 0.16 in / 4 mm
g 1.57 in / 40 mm
h 0.24 in / 6 mm
i 0.67 in / 17 mm
j 1.02 in / 26 mm
k 0.20 in / 5 mm
l 0.59 in / 15 mm
m 0.39 in / 10 mm
n 0.79 in / 20 mm
o 0.51 in / 13 mm
p 0.22 in / 5.5 mm
q 1.18 in / 30 mm
r 1.65 in / 42 mm
s 4.72 in / 120 mm
t 0.63 in / 16 mm
u 0.25 in / 6.3 mm
v 0.29 in / 7.3 mm
w 0.28 in / 7 mm
x 2.36 in / 60 mm
y 1.77 in / 45 mm
z 0.21 in / 5.3 mm
aa 0.98 in / 25 mm
bb 2.95 in / 75 mm
Multipliers For Nominal
Various Metals Switching Distance
37 Stainless Steel 1.0 x Sn
18/8 High Grade Stainless Steel 0.9 x Sn
Brass 0.6 x Sn
Aluminum 0.5 x Sn
Copper 0.4 x Sn
47
Inductive Proximity Sensors
AC Proximity Sensors, Cylinder Barrel Design,
Order Number Cable 150464 150466 150468 150470
Part No./Type SIEW-M12B-ZS-K-L SIEW-M12B-ZO-K-L SIEW-M12NB-ZS-K-L SIEW-M12NB-ZO-K-L
Plug 150465 150467 150469 150471
SIEW-M12B-ZS-S-L SIEW-M12B-ZO-S-L SIEW-M12NB-ZS-S-L SIEW-M12NB-ZO-S-L
Operation Normally Open Normally Closed Normally Open Normally Closed
Design Non-contact electrical signal generator
Mounting Flush mounting Non flush mounting
Installation Diameter M12 x 1 Threaded
Nominal Switching Distance Sn 0.08 in / 2 mm 0.16 in / 4 mm
Actual Switching Distance Sr 0.070 to 0.087 in / 1.80 to 2.20 mm 0.142 to 0.173 in / 3.60 to 4.40 mm
Useful Switching Distance Su 0.063 to 0.094 in / 1.60 to 2.40 mm 0.126 to 0.189 in / 3.20 to 4.80 mm
Working Switching Distance Sa 0.063 in / 1.60 mm 0.126 in / 3.20 mm
Reproducibility R 0.004 in / 0.10 mm 0.008 in / 0.20 mm
Switching Hysteresis H 0.002 to 0.016 in / 0.06 to 0.40 mm 0.005 to 0.031 in / 0.12 to 0.80 mm
Line Voltage Range UB 20 to 265 VAC
Mains Frequency 45 to 65 Hz
Open Circuit Current Io < = 1.5 mA
Output Switching Current Ie 300 mA
Voltage Drop Ud < = 6 V
Residual Current Ir < = 1.5 mA
Minimum Load Current Im 5 mA
Intermittent Current Ik 3 A (20 ms, 1 Hz)
Switching Frequency f 25 Hz 25 Hz
Ambient Temperature Ta -13 to 185F / -25 to +85C
Short Circuit Protection None
Induced Voltage Protection Included
Insulation Characteristics Sine-formed test voltage 500 V, Pulse voltage IEC 255-5 1 kV
Type of Protection IP 67
Housing Material Nickel-plated brass
Connector Information PUR-Cable 8.2 ft / 2.5 m long, Socket with cable SIM-M12-...
Weight 0.22 lb / 0.10 kg w/Cable 0.09 lb / 0.04 kg w/Cable
48 (Ref. 8.1/40-1) (97/98) Subject to change
Inductive Proximity Sensors
For al ternati ng current 2 conductor
technology, inductive with integral yellow
LED status indicator.
Flush Mounted
Thread Size M12 x 1
Type SIEW-M12B-...
Non Flush Mounting
Thread Size M12 x 1
Type SIEW-M12NB-...
When a metallic object is within the
switching distance of the active blue face
of the sensor, an electrical signal is
generated.
An integral yellow LED is on whenever a
signal is generated.
Accessories:
Socket with Cable, Type SIM-M12-...
See page 54.
Mounting Block, Type SDA-12 x 1-B
See page 57.
Foot Mount, Type HBN-8/10 x 1
See page 58.
Type SIEW-M12B-... Type SIEW-M12NB-...
Flush Mounted Non Flush Mounting
With cable With plug With cable With plug
Normally Open Contact Normally Closed Contact
With cable With plug With cable With plug
AC
N.O.
Color Codes
BK = Black
Note: These sensors are Class A products. In indoor environments, induced interference can cause malfunction. If this occurs, move the sensor to a more suitable
location.
Pin Allocation
for Models with Plug
Contact
Normally open contact
Output
Normally closed contact
AC
N.O.
AC
N.C.
AC
N.C.
Sensor Tester
158481 SM-TEST-1
The sensor tester is used for checking
the functioning of proximity sensors.
See page 245.
49 Subject to change (Ref. 8.1/40-2) (97/98)
Dimensions
a 2.20 in / 56 mm
b 1.61 in / 41 mm
c 0.16 in / 4 mm
d 0.18 in / 4.5 mm
e 2.56 in / 65 mm
f 1.75 in / 44.5 mm
g 0.24 in / 6 mm
h 0.47 in / 12 mm
i 0.20 in / 5 mm
j 2.44 in / 62 mm
k 1.85 in / 47 mm
l 0.26 in / 6.5 mm
m 2.80 in / 71 mm
n 1.99 in / 50.5 mm
o 0.59 in / 15 mm
p 1.06 in / 27 mm
q 0.31 in / 8 mm
r 0.35 in / 9 mm
Inductive Proximity Sensors
Dimensions
Thread Size M12 x 1, Flush Mounted
Type SIEW-M12B-...
Cable Plug Mounting Method
c
b
a
d
c
f
e g h
i
Thread Size M12 x 1, Non Flush Mounting
Type SIEW-M12NB-...
Cable Plug Mounting Method
c
l
k
j
d
c
l
n
m
o p
q
r
q
Multipliers For Nominal Nominal
Various Metals Switching Distance Switching Distance
Type SIEW-M12B-... SIEW-M12B-...
37 Stainless Steel 1.0 x Sn 1.0 x Sn
18/8 High Grade Stainless Steel 0.9 x Sn 0.9 x Sn
Brass 0.6 x Sn 0.6 x Sn
Aluminum 0.5 x Sn 0.5 x Sn
Copper 0.4 x Sn 0.4 x Sn
2-wire cable 8.2 ft / 2.5 m long
(2 x 0.25 mm
2
)
Active area
1 yellow operating status indicator
Metal-free area
= Wrench size in mm
5
3
2
1
Type SIEW-M18B-... Type SIEW-M18NB-...
Flush Mounted Non Flush Mounting
With cable With plug With cable With plug
Normally Open Contact Normally Closed Contact
With cable With plug With cable With plug
(Ref. 8.1/41-1) (97/98) Subject to change
Inductive Proximity Sensors
AC Proximity Sensors, Cylinder Barrel Design,
Inductive Proximity Sensors
For al ternati ng current 2 conductor
technology, inductive with integral yellow
LED status indicator.
Flush Mounted
Thread Size M18 x 1
Type SIEW-M18B-...
Non Flush Mounting
Thread Size M18 x 1
Type SIEW-M18NB-...
When a metal l i c obj ect i s wi thi n the
switching distance of the active blue face
of the sensor, an el ectri cal si gnal i s
generated.
An integral yellow LED is on whenever a
signal is generated.
Accessories:
Socket with Cable, Type SIM-M12-...
See page 54.
Sensor Tester
158481 SM-TEST-1
The sensor tester is used for checking
the functioning of proximity sensors.
See page 245.
Color Codes
BK = Black
Note: These sensors are Class A products. In indoor environments, induced interference can cause malfunction. If this occurs, move the sensor to a more suitable
location.
Order Number Cable 150472 150474 150476 150478
Part No./Type SIEW-M18B-ZS-K-L SIEW-M18B-ZO-K-L SIEW-M18NB-ZS-K-L SIEW-M18NB-ZO-K-L
Plug 150473 150475 150477 150479
SIEW-M18B-ZS-S-L SIEW-M18B-ZO-S-L SIEW-M18NB-ZS-S-L SIEW-M18NB-ZO-S-L
Operation Normally Open Normally Closed Normally Open Normally Closed
Design Non-contact electrical signal generator
Mounting Flush mounted Non flush mounting
Installation Diameter M18 x 1 Threaded
Nominal Switching Distance Sn 0.20 in / 5 mm 0.31 in / 8 mm
Actual Switching Distance Sr 0.177 to 0.217 in / 4.50 to 5.50 mm 0.283 to 0.346 in / 7.20 to 8.80 mm
Useful Switching Distance Su 0.157 to 0.236 in / 4.00 to 6.00 mm 0.256 to 0.382 in / 6.50 to 9.70 mm
Working Switching Distance Sa 0.157 in / 4.00 mm 0.256 in / 6.50 mm
Reproducibility R 0.006 in / 0.15 mm 0.008 in / 0.20 mm
Switching Hysteresis H 0.006 to 0.039 in / 0.15 to 1.00 mm 0.009 to 0.063 in / 0.24 to 1.60 mm
Line Voltage Range UB 20 to 265 VAC
Mains Frequency 45 to 65 Hz
Open Circuit Current Io < = 1.5 mA
Output Switching Current Ie 300 mA
Voltage Drop Ud < = 6 V
Residual Current Ir < = 1.5 mA
Minimum Load Current Im 5 mA
Minimum Load Current Ik 3 A (20 ms, 1 Hz)
Switching Frequency f 25 Hz 25 Hz
Ambient Temperature Ta -13 to 185F / -25 to +85C
Short Circuit Protection None
Induced Voltage Protection Included
Insulation Characteristics Sine-formed test voltage 2000 V, Pulse voltage IEC 255-5 1 kV
Type of Protection IP 67
Housing Material Nickel-plated brass
Connector Information PUR-Cable 8.2 ft / 2.5 m long, Socket with cable SIM-M12-...
Weight 0.26 lb / 0.12 kg w/Cable 0.09 lb / 0.04 kg w/Cable
AC
N.O.
Pin Allocation
for Models with Plug
Contact
Normally open contact
Output
Normally closed contact
AC
N.O.
AC
N.C.
AC
N.C.
50
51 Subject to change (Ref. 8.1/41-2) (97/98)
Dimensions
a 2.13 in / 54 mm
b 1.65 in / 42 mm
c 0.16 in / 4 mm
d 0.18 in / 4.5 mm
e 2.70 in / 68.5 mm
f 0.43 in / 11 mm
g 0.83 in / 21 mm
h 0.39 in / 10 mm
i 0.41 in / 10.5 mm
j 0.79 in / 20 mm
k 1.10 in / 28 mm
l 0.59 in / 15 mm
Inductive Proximity Sensors
Dimensions
Thread Size M18 x 1, Flush Mounted
Type SIEW-M18B-...
Cable Plug Mounting Method
c
a
b
d
c
b
e
g f
h
Thread Size M18 x 1, Non Flush Mounting
Type SIEW-M18NB-...
Cable Plug Mounting Method
c
i
b
a
d
c i
b
e
j k
f
l
f
2-wire cable 8.2 ft / 2.5 m long
(2 x 0.25 mm
2
)
Active area
1 yellow operating status indicator
Metal-free area
= Wrench size in mm
5
3
2
1
Multipliers For Nominal Nominal
Various Metals Switching Distance Switching Distance
Type SIEW-M18B-... SIEW-M18NB-...
37 Stainless Steel 1.0 x Sn 1.0 x Sn
18/8 High Grade Stainless Steel 0.7 x Sn 0.7 x Sn
Brass 0.4 x Sn 0.4 x Sn
Aluminum 0.4 x Sn 0.4 x Sn
Copper 0.3 x Sn 0.3 x Sn
52 (Ref. 8.1/42-1) (97/98) Subject to change
Order Number Cable 150480 150482 150484 150486
Part No./Type SIEW-M30B-ZS-K-L SIEW-M30B-ZO-K-L SIEW-M30NB-ZS-K-L SIEW-M30NB-ZO-K-L
Plug 150481 150483 150485 150487
SIEW-M30B-ZS-S-L SIEW-M30B-ZO-S-L SIEW-M30NB-ZS-S-L SIEW-M30NB-ZO-S-L
Operation Normally Open Normally Closed Normally Open Normally Closed
Design Non-contact electrical signal generator
Mounting Flush mounted Non flush mounting
Installation Diameter M30 x 1 Threaded
Nominal Switching Distance Sn 0.39 in / 10 mm 0.59 in / 15 mm
Actual Switching Distance Sr 0.354 to 0.433 in / 9.00 to 11.00 mm 0.531 to 0.650 in / 13.50 to 16.50 mm
Useful Switching Distance Su 0.319 to 0.476 in / 8.10 to 12.10 mm 0.478 to 0.715 in / 12.15 to 18.15 mm
Working Switching Distance Sa 0.319 in / 8.10 mm 0.478 in / 12.15 mm
Reproducibility R 0.019 in / 0.30 mm 0.016 in / 0.40 mm
Switching Hysteresis H 0.019 to 0.079 in / 0.30 to 2.00 mm 0.018 to 0.118 in / 0.45 to 3.00 mm
Line Voltage Range UB 20 to 265 VAC
Mains Frequency 45 to 65 Hz
Open Circuit Current Io < = 1.5 mA
Output Switching Current Ie 300 mA
Voltage Drop Ud < = 6 V
Residual Current Ir < = 1.5 mA
Minimum Load Current Im 5 mA
Minimum Load Current Ik 3 A (20 ms, 1 Hz)
Switching Frequency f 25 Hz 25 Hz
Ambient Temperature Ta -13 to 185F / -25 to +85C
Short Circuit Protection None
Induced Voltage Protection Included
Insulation Characteristics Sine-formed test voltage 2000 V, Pulse voltage IEC 255-5 1 kV
Type of Protection IP 67
Housing Material Nickel-plated brass
Connector Information PUR Cable 8.2 ft / 2.5 m long, Socket with cable SIM-M12-...
Weight 0.37 lb / 0.17 kg w/Cable 0.22 lb / 0.1 kg w/Cable
Inductive Proximity Sensors
AC Proximity Sensors, Threaded Barrel Design,
Inductive Proximity Sensors
For al ternati ng current 2 conductor
technology, inductive with integral yellow
LED status indicator.
Flush Mounted
Thread Size M30 x 1.5
Type SIEW-M30B-...
Non Flush Mounting
Thread Size M30 x 1.5
Type SIEW-M30NB-...
When a metal l i c obj ect i s wi thi n the
switching distance of the active blue face
of the sensor, an el ectri cal si gnal i s
generated.
An integral yellow LED is on whenever a
signal is generated.
Accessories:
Socket with Cable, Type SIM-M12-...
See page 54.
Foot Mount, Type FV-32
See page 58.
Sensor Tester
158481 SM-TEST-1
The sensor tester is used for checking the
functioning of proximity sensors.
See page 245.
Type SIEW-M30B-... Type SIEW-M30NB-...
Flush Mounted Non Flush Mounting
With cable With plug With cable With plug
Normally Open Contact Normally Closed Contact
With cable With plug With cable With plug
Color Codes
BK = Black
Note: These sensors are Class A products. In indoor environments, induced interference can cause malfunction. If this occurs, move the sensor to a more suitable
location.
AC
N.O.
Pin Allocation
for Models with Plug
Contact
Normally open contact
Output
Normally closed contact
AC
N.O.
AC
N.C.
AC
N.C.
Inductive Proximity Sensors
Dimensions
53 Subject to change (Ref. 8.1/42-2) (97/98)
Thread Size M30 x 1.5, Flush Mounted
Type SIEW-M30B-...
Cable Plug Mounting Method
d
c
b
a
A2.384-6A(10.95)
c
b
e
g f
h
A2.384-6C(10.95)
Thread Size M30 x 1.5, Non Flush Mounting
Type SIEW-M30NB-...
Cable Plug Mounting Method
c
b
a
i
d
c
b
i
e
j k
f
l
f
2-wire cable 8.2 ft / 2.5 m long
(2 x 0.25 mm
2
)
Active area
1 yellow operating status indicator
Metal-free area
= Wrench size in mm
5
3
2
1
Dimensions
a 2.13 in / 54 mm
b 1.65 in / 42 mm
c 0.20 in / 5 mm
d 0.18 in / 4.5 mm
e 2.70 in / 68.5 mm
f 0.98 in / 25 mm
g 1.46 in / 37 mm
h 0.63 in / 16 mm
i 0.61 in / 15.5 mm
j 1.18 in / 30 mm
k 3.15 in / 80 mm
l 0.59 in / 15 mm
Multipliers For Nominal Nominal
Various Metals Switching Distance Switching Distance
Type SIEW-M30B-... SIEW-M30NB-...
37 Stainless Steel 1.0 x Sn 1.0 x Sn
18/8 High Grade Stainless Steel 0.7 x Sn 0.7 x Sn
Brass 0.4 x Sn 0.4 x Sn
Aluminum 0.4 x Sn 0.4 x Sn
Copper 0.3 x Sn 0.3 x Sn
54 (Ref. 8.4/10-3) (97/98) Subject to change
Accessories
Sockets / Cables, with Threaded Connector Nut, IP67
Socket
With Connector Nut
and High Flexibility Cable
(Screw-on Socket Connection)
For Sensors with 3-Pin Threaded Socket
Connection
Type SIM-M8-3...-PU
SIM-M12-3...-PU
For Sensors with 3-Pin Threaded Socket
Connection, PNP or NPN Output
Type SIM-M8-3...-PSL-PU
SIM-M8-3...-NSL-PU
SIM-M12-3...-PSL-PU
SIM-M12-3...-NSL-PU
For Sensors with 4-Pin Threaded Socket
Connection
Type SIM-M8-4...-PU
SIM-M12-4...-PU
Cable
Oil-resistant per DIN VDE 0472 Section
803
Hi ghl y fl exi bl e wi th twi sti ng charac-
teristics per DIN VDE 0472 Section 603;
Test F: 40000
Materials:
Casing: PUR
Conductor insulation: PVC
Socket: PUR
Temperature Range:
Flexible: +23 to +158F / -5 to +70C
Non-Flexible: -22 to +158F / -30 to
+70C
Type SIM-M8-3GD-...-PU Type SIM-M8-3WD-...-PU
Type SIM-M12-3GD-...-PU Type SIM-M12-3WD-...-PU
Switching diagram
for sensor with PNP switching output for sensor with NPN switching output.
Type SIM-M8-4GD-...-PU Type SIM-M8-4WD-...-PU
Type SIM-M12-4GD-...-PU Type SIM-M12-4WD-...-PU
Type of Protection: IP67
M8 x 1 M12 x 1
Order Number Order Number
Part No. Type Part No. Type Cable Length Description
159420 SIM-M8-3GD-2.5-PU 159428 SIM-M12-3GD-2.5-PU 8.2 ft / 2.5 m Socket for Sensors with 3 pin
159421 SIM-M8-3GD-5-PU 159429 SIM-M12-3GD-5-PU 16.4 ft / 5 m threaded socket connection
159422 SIM-M8-3WD-2.5-PU 159430 SIM-M12-3WD-2.5-PU 8.2 ft / 2.5 m
159423 SIM-M8-3WD-5-PU 159431 SIM-M12-3WD-5-PU 16.4 ft / 5 m
159424 SIM-M8-3WD-2.5-PSL-PU 159432 SIM-M12-3WD-2.5-PSL-PU 8.2 ft / 2.5 m ...for PNP Switching Output, normally
159425 SIM-M8-3WD-5-PSL-PU 159433 SIM-M12-3WD-5-PSL-PU 16.4 ft / 5 m open function and LED
159426 SIM-M8-3WD-2.5-NSL-PU 159434 SIM-M12-3WD-2.5-NSL-PU 8.2 ft / 2.5 m ...for NPN Switching Output, normally open
159427 SIM-M8-3WD-5-NSL-PU 159435 SIM-M12-3WD-5-NSL-PU 16.4 ft / 5 m function and LED
158960 SIM-M8-4GD-2.5-PU Socket for sensors with 4 pin threaded
158961 SIM-M8-4GD-5-PU 164259 SIM-M12-4GD-5-PU 16.4 ft / 5 m socket connection
158962 SIM-M8-4WD-2.5-PU
158963 SIM-M8-4WD-5-PU 164258 SIM-M12-4WD-5-PU 16.4 ft / 5 m
A2.385-3A(10.95)
A2.385-3B(10.95)
green yellow
/
/
Connection Diagram
1 = Blue
2 = Black
3 = Brown
Connection Diagram
1 = Brown
2 =
3 = Blue
4 = Black
green yellow
/
/
Connection Diagram
1 = Brown
2 = White
3 = Blue
4 = Black
Connection Diagram
1 = Brown
2 = White
3 = Blue
4 = Black
Color Codes
BK = Black BN = Brown BU = Blue
55 Subject to change (Ref. 8.4/10-4) (97/98)
Type SIM-M8-3GD-...-PU Type SIM-M8-3WD-...-PU
d
a
b
c
d e
f
h
g
a
Dimensions
a 0.17 in / 4.2 mm
b 0.96 in / 24.4 mm
c 1.27 in / 32.3 mm
d 0.35 in / 9 mm
e 0.31 in / 8 mm
f 1.04 in / 26.3 mm
g 0.36 in / 9.2 mm
h 0.67 in / 17.1 mm
i 0.59 in / 15 mm
j 1.14 in / 29 mm
k 1.63 in / 41.5 mm
l 1.26 in / 32 mm
m 0.47 in / 12 mm
n 0.96 in / 24.5 mm
o 0.18 in / 4.5 mm
Accessories
Dimensions for Sockets / Cables
Cable
Wire Construction 65 x 0.07 mm
Wire Cross-section 3 x 0.25 mm
2
Max. Current Imax 2.8 A
Max Voltage Umax 60 VAC
75 VDC
Insulation Failure Voltage 2000 V
Cable, Type ...-PSL and ...-NSL
Wire Construction 65 x 0.07 mm
Wire Cross-section 3 x 0.25 mm
2
Max. Current Imax 2.8 A
Max Voltage Umax 10 to 30 VDC
Insulation Failure Voltage 2000 V
Type SIM-M12-3GD-...-PU Type SIM-M12-3WD-...-PU
a
i
i
j
k
i
i
l
m
n
a
Cable
Wire Construction 65 x 0.07 mm
Wire Cross-section 3 x 0.25 mm
2
Max. Current Imax 4 A
Max Voltage Umax 250 VAC
300 VDC
Insulation Failure Voltage 2000 V
Cable, Type ...-PSL and ...-NSL
Wire Construction 65 x 0.07 mm
Wire Cross-section 3 x 0.25 mm
2
Max. Current Imax 4 A
Max Voltage Umax 10 to 30 VDC
Insulation Failure Voltage 2000 V
Type SIM-M8-4GD-...-PU Type SIM-M8-4WD-...-PU
o
d
b
c
e d
f
o
g
h
Cable
Wire Construction 65 x 0.07 mm
Wire Cross-section 4 x 0.25 mm
2
Max. Current Imax 2.8 A
Max Voltage Umax 60 VAC
75 VDC
Insulation Failure Voltage 2000 V
Type SIM-M12-4GD-...-PU Type SIM-M12-4WD-...-PU
o
i
i
j
k
i
i
l
o
m
n
Cable
Wire Construction 65 x 0.07 mm
Wire Cross-section 4 x 0.25 mm
2
Max. Current Imax 4 A
Max Voltage Umax 250 VAC
300 VDC
Insulation Failure Voltage 2000 V
Connector nut M8 x 1 or M12 x 1, heavy duty
Operating status LED, Yellow
Power on LED, Green
3
2
1
}
Types PSL and NSL only.
56 (Ref. 8.4/10-1, 10-2) (97/98) Subject to change
Accessories
Sockets / Operational Status Indicator
Straight Socket
Type SIE-GD
Material: PBTB
Angle Socket
Type SIE-WD-TR
Material: PBTB/PA
Operational Status Indicator
Type SIE-LP-LED-GR
For Angle Socket
The operational status indicator can be
installed into the angle socket, Type SIE-
WD-TR
A green LED indicates if line voltage is
present.
A sensors integral LED lights when the
sensor sends an electric signal.
Order Number
Part No. Type Description
18494 SIE-GD For sensors with plug, thread size M12 x 1
12956 SIE-WD-TR For sensors with plug, thread size M12 x 1
12957 SIE-LP-LED-GR LED for angle socket, Type SIE-WD-TR
Connection Diagram
red
blue
green
Type SIE-GD
Type SIE-WD-TR
Type SIE-LP-LED-GR
Socket
Max. Current Imax 3 A
Max Voltage Umax 125 VAC
150 VDC
Temperature Range -40 to +185F
-40 to +85C
b
a
c
d
j k
i
i
h
f
g
e
Terminals 4 x 90plug-in connection
Cable diameter 0.16 to 0.24 in / 4 to 6 mm
2
1
Angle Socket
Max. Current Imax 3 A
Max Voltage Umax 125 VAC
150 VDC
Temperature Range -40 to +185F
-40 to +85C
Operating Status Indicator
Max Voltage Umax 28 VDC
Max Current Imax 20 mA
Dimensions
a 2.13 in / 54 mm
b 0.79 in / 20 mm
Dimensions
c 0.98 in / 25 mm
d 0.58 in / 14.8 mm
e 0.32 in / 8.2 mm
f 1.38 in / 35 mm
g 1.42 in / 36 mm
h 0.71 in / 18 mm
i 0.20 in / 5 mm
j 0.81 in / 20.5 mm
k 1.50 in / 38 mm
Order Number
Part No. Type Description
11542 SDA-8 X 1-B For sensors with M8 x 1 Thread
11541 SDA-12 X 1-B For sensors with M12 x 1 Thread
57 Subject to change (Ref. 8.4/20-1) (97/98)
Accessories
Mounting Blocks
Mounting Block
For Sensors
With M8 x 1 Thread
Type SDA-8 x 1-B
With M12 x 1 Thread
Type SDA-12 x 1-B
Type B
1
B
2
D
1
D
2
D
3
D
4
H
1
H
2
in / mm in / mm in / mm in / mm in / mm in / mm in / mm
SDA-8 x 1-B 0.79 / 20 0.39 / 10 M8 x 1 0.31 / 8 0.17 / 4.4 0.15 / 3.8 0.59 / 15 0.30 / 7.5
SDA-12 X 1-B 1.06 / 27 0.55 / 14 M12 x 1 0.43 / 11 0.26 / 6.6 0.23 / 5.8 0.79 / 20 0.39 / 10
Type L
1
L
2
L
3
T
1
T
2
Weight
P9
in / mm in / mm in / mm in / mm in / mm lbs / kg
SDA-8 x 1-B 1.10 / 28 0.71 / 18 0.16 / 4 0.16 / 4 0.06 / 1.5 0.11 / 0.050
SDA-12 X 1-B 1.57 / 40 1.06 / 27 0.24 / 6 0.27 / 6.8 0.08 / 2 0.25 / 0.115
58 (Ref. 8.4/20-2) (97/98) Subject to change
d
s
r
w
u
v
t r
t
i
Accessories
Foot Mounting / Mounting Brackets
Foot Mounting
For Sensor with Thread Size M12
Type HBN-8/10x 1
For Sensor with thread size M30
Type FV-32
Mounting Bracket
For Sensor Type SIES-V3B-...
Type HV-M5
Type HBN-8/10 x 1
Type FV-32
Type HV-M5
f
g c
h
e
b
b d
R
a
k
j
j
l
q
p
n
l
o
i
x
Order Number Weight
Part No. Type Description lb / kg
5123 HBN-8/10 x 1 Foot mounting for sensor with M12 thread 0.044 / 0.020
3754 FV-32 Foot mounting for sensor with M30 thread 0.22 / 0.100
9634 HV-M5 Mounting bracket for Sensor Type SIES-V3B-... 0.044 / 0.020
Dimensions
a 0.39 in / 10 mm
b 0.63 in / 16 mm
c 0.98 in / 25 mm
d 1.38 in / 35 mm
e 0.12 in / 3 mm
f 0.48 in / 12.1 mm
g 0.44 in / 11 mm
h 0.18 in / 4.5 mm
i 0.16 in / 4 mm
j 0.56 in / 14 mm
k 0.83 in / 21 mm
l 1.11 in / 28 mm
m 1.19 in / 30.1 mm
n 1.95 in / 49 mm
o 2.62 in / 66 mm
p 2.06 in / 52 mm
q 0.28 in / 7 mm
r 0.32 in / 8 mm
s 0.79 in / 20 mm
t 0.17 in / 4.3 mm
u 0.48 in / 12 mm
v 0.06 in / 1.5 mm
w 0.67 in / 17 mm
x 1.19 in / 30.1 mm