EDAU 12 - 722

- Heat Pump -

E-Series

EDAU12-722

Part 1 Features ............................................................................ 1


1. Outdoor Units ..........................................................................................2
2. Indoor Units.............................................................................................3
2.1 Wall Mounted Type ..................................................................................3
2.2 Duct Connected Type...............................................................................8
2.3 Floor / Ceiling Suspended Dual Type.......................................................8

Part 2 Multi-Split System Room Air Conditioners


SUPER MULTI NX E-Series Heat Pump ............................. 9
1. Power Supply ........................................................................................11
2. Functions...............................................................................................12
3. Specifications ........................................................................................16
3.1 Indoor Units ............................................................................................16
3.2 Outdoor Units .........................................................................................22
3.3 Combination Capacity ............................................................................24

4. Dimensions ...........................................................................................42
4.1 Indoor Units ............................................................................................42
4.2 Outdoor Units .........................................................................................51

5. Wiring Diagrams....................................................................................53
5.1 Indoor Units ............................................................................................53
5.2 Outdoor Units .........................................................................................57

6. Piping Diagrams....................................................................................59
6.1 Indoor Units ............................................................................................59
6.2 Outdoor Units .........................................................................................63

7. Capacity Tables ....................................................................................65


7.1 Total Capacity ........................................................................................65
7.2 Capacity Correction Factor by the Length of Refrigerant Piping
(Reference) ..........................................................................................165

8. Operation Limit....................................................................................166
9. Fan Characteristics .............................................................................167
9.1 External Static Pressure.......................................................................167

10.Sound Level ........................................................................................170


10.1 Measuring Location ..............................................................................170
10.2 Octave Band Level ...............................................................................171

11.Electric Characteristics........................................................................177

Part 3 Installation Manual ....................................................... 179


1. Indoor Units.........................................................................................180
1.1
1.2
1.3
1.4
1.5
1.6
1.7
1.8
1.9

SUPER MULTI NX E-Series

Safety Precautions ...............................................................................180


Wall Mounted Type FTXS 20 D............................................................181
Wall Mounted Type FTXS 25/35 E.......................................................189
Wall Mounted Type FTXS 50/60/70 F ..................................................196
Duct Connected Type FDXS 25/35/50/60 C ........................................203
Duct Connected Type CDXS 25/35 E ..................................................211
Floor / Ceiling Suspended Dual Type FLXS 25/35/50/60 B .................219
Floor Standing Type FVXS 25/35/50 F ................................................227
Ceiling Mounted Cassette Type FFQ 25/35/50/60 B............................238

EDAU12-722

2. Outdoor Units ......................................................................................260


2.1
2.2
2.3
2.4

Safety Precautions ...............................................................................260


3MXS52EVMA .....................................................................................261
3MXS68EVMA .....................................................................................275
4MXS80EVMA .....................................................................................289

Part 4 Operation Manual .......................................................... 303


1. Instruction............................................................................................304
1.1 FTXS, CDXS, FDXS, FLXS Series ......................................................304
1.2 FVXS Series.........................................................................................363
1.3 FFQ Series ...........................................................................................393

Part 5 Options .......................................................................... 405


1. Optional Accessories ..........................................................................406
1.1 Option List ............................................................................................406
1.2 Installation Manual ...............................................................................408

ii

SUPER MULTI NX E-Series

EDAU12-722

Part 1
Features
1. Outdoor Units ..........................................................................................2
2. Indoor Units.............................................................................................3
2.1 Wall Mounted Type ..................................................................................3
2.2 Duct Connected Type...............................................................................8
2.3 Floor / Ceiling Suspended Dual Type.......................................................8

Features

Outdoor Units

EDAU12-722

1. Outdoor Units
Features
- New Indoor Units
- Floor standing type 25/35/50 class
Stylish front panel design

3MKS58/75EVMA
3MXS52/68EVMA

4MKS90EVMA
4MXS80EVMA

06RAG14-4

External Appearance
Wall Mounted

Floor Standing

Duct Connected
< CDKS25-60C >
< FDXS25-60C >

< CDK(X)S25-35EA >

< FVXS25-50F>

< FTK(X)S20D >


< FTK(X)S25-35E >

Floor/Ceiling

< FTK(X)S50-71F >

< FLXS25-60B>

Cassette
< FFQ25-60B8 > 600x600

Note) Floor standing type and floor/ceiling suspended dual type are only for
heat pump models

05RAG15B- 8

Swing Compressor
Large Energy Savings
Smooth rotation with little friction and refrigerant gas
compression with little loss, allowing high operation
efficiency

Low Vibrations and Low Noise


Smooth piston motion as if sliding along a groove,
resulting in low vibrations and low noise

High Durability
Few parts rubbing each other during operation,
achieving high performance and reliability

Reluctance DC Motor
Higher efficiency with 2 different torques
magnetic torque of ND magnet
and reluctance torque
Distinctive effect in energy-saving
running in low-frequency zone

Neodymium
magnet

Ferrite
magnet

05RAG15B- 11

Features

EDAU12-722

Indoor Units

2. Indoor Units
2.1

Wall Mounted Type

2.1.1

20-35 Class

Features
< Indoor Unit >

Stylish Flat Design


Higher Energy Saving
High Grade DC Inverter Model
-DC Compressor (Reluctance DC Motor)
-DC Fan Motor

Quiet Sound Levels


Comfortable Functions
Easy Maintenance
Wipe-clean Flat Panel
Removable Drain Pan

Pair/Multi Compatible Indoor Unit


05RAG19A- 4

Installation Example

05RAG19A- 6

ECONO Mode
Decrease the Operating Current
The "ECONO mode" reduces the maximum operating current and power
consumption by approx. 30% during start up etc..
This mode is particularly convenient for energy-saving-oriented users. It
is also a major bonus for those whose breaking capacities do not allow the
use of multiple electrical devices and air conditioners.
It is easily activated from the wireless remote controller by pushing the
ECONO button.
Operation Image

05RAG19A- 17

Features

Indoor Units

EDAU12-722

ECONO Mode
Notes
- When this function is ON, the maximum capacity is
also down. (Approx. 20%)
- In case of the multi system connection, the unit drops
maximum capacity to equal level with nominal
capacity in stead of current control.
- This function can only be set when the unit is running.
Pressing the operation stop button causes the
settings to be canceled.
- This function and "Powerful operation" cannot be
used at the same time. (Priority is given to Powerful
operation.)

05RAG19A- 18

Intelligent Eye
= Sensing human presence utilizing infrared rays =

Coverage Area
within 7 m (Max)
Intelligent Eye
Sensor

110
Max.
7m

90

05RAG19A- 19

Intelligent Eye
= Just one push of the [SENSOR] button =

QUIET

Sensor

05RAG06A-8

Features

EDAU12-722

Indoor Units

Energy Saving Functions

Intelligent Eye
= Automatic shift up when sensing no human, intelligently saving energy =

Cooling

Temperature

Energy
Saving
operation

Absence 20min

Power consumption

Normal
operation

Saving
20%!

Back to
normal
operation
when
presence
detected

2C Shift up
Minimum frequency
(34Hz)

Normal
operation

Normal
operation

time

Energy saving
operation
activated

05RAG19A- 21

Intelligent Eye
= When absence shift down automatically makes energy saving intelligently =

Heating

Energy
Saving
operation

Absence 20min

Power consumption

Temperature

2C Shift down
Minimum frequency
(34Hz)

Normal
operation

Saving
30%!

Returns to
normal operation
upon sensing
a sign of human

Normal
operation

Normal
operation

Energy saving
operation
activated

time
05RAG19A- 22

6 Steps Air Flow Rate


Air Flow Setting on the R/C
Indoor Unit Quiet Operation

Selectable 6 steps air flow rate


(5 steps and Quiet) make fine
on-demand comfort.
Quiet Operation for Better Sleep

SL

L ML M MH H
Decrease sound level

A sound level step by step decreases


approximately 2 or 3 dB by choosing
smaller airflow setting.

05RAG19A- 23

Features

Indoor Units

EDAU12-722

Indoor Unit Quiet Operation


When air flow is set to Quiet through a remote controller,
the operation sound of the indoor unit is reduced by 3dB.
This is a convenient function while studying or sleeping.
Air flow setting button

Auto

Super
Low (SL)

Low
(L)

Middle
(M)

High
(H)

Indoor unit s fan


<Note>

If the unit operates in SL or


L mode with small air flow,
operating noise is reduced but
cooling / heating capacity is
reduced too.

M
L
SL
Quiet ON

05RAG19A- 24

Outdoor Unit Quiet Operation


When QUIET button is selected,
the outdoor unit s operation
sound reduces by 3dB.
In night time operation, the unit
can be operated with less
nuisance to the neighborhood.

Outdoor Unit Quiet Operation button

Lowering the revolution


speed of the
compressor and fan.

3dB down

05RAG06A-14

Mold Proof Function


After cooling or dry operation, some drain
water remains inside the indoor unit (on
the heat exchanger, the drain pan, etc...).
This moisture causes the generation of
mold.

The "Mold Proof Operation"


reduces the spread of mold,
and decreases nasty odors that
is caused by the mold.

Heat Exchanger

Drain Pan

05RAG19A- 28

Features

EDAU12-722

Indoor Units

1
Mold Proof Function
Press and hold the "MOLD PROOF" button for 2
seconds in advance.
When the unit turned off after cooling or dry operation,
the unit starts fan
operation at a slow
speed* for
approximately 1 hour.
The fan operation
vaporizes the moisture
inside the unit.

Note) * : the fan rotation speed is slower than the


"Indoor Unit Silent Operation".

05RAG19A- 29

Mold Proof Function


Notes
- This function is not designed to remove existing dust
or mold.
- This function is not available when the unit is turned
off using the off timer.
- During this function is operated,
the flaps open a little and
air
the air is blown upward slightly.
Fraps

05RAG19A- 30

50-71 class models also have this function.

Titanium Apatite Photocatalytic


Air-Purifying Filter
It lasts for three years without replacement
if washed about once every six months.
Absorbs microscopic particles, decomposes odours and even deactivates
bacteria and viruses.

ABSORB

REMOVE

05RAG19A- 31

Features

Indoor Units

2.2

EDAU12-722

Duct Connected Type


Feautures

< CDKS25-60C >


< FDXS25-60C >

Quiet Operation
Slim Design (Height 200 mm)
External Static Pressure
40 Pa

04RAGN-5

Feautures
Installation Example
<CDK(X)S2535E>

Saving Space
More Compact W700mm
Slim Height H200mm

Comfortable Functions
for Residential Use

06RAG08-2

2.3

Floor / Ceiling Suspended Dual Type


Feautures

< FLX25-60B >

Energy Saving
High COP

Comfortable Air Flow


Wide-Angle lourvres
(Auto swing right & left)

Healthy & Clean functions


Photocatalytic Deodorizing Filter
Air Purifying Filter

Pair / Multi Compatible indoor Unit

03RAGA-39

Features

EDAU12-722

Part 2
Multi-Split System
Room Air Conditioners
SUPER MULTI NX
E-Series
Heat Pump
FTXS20DVMA
FTXS25EVMA
FTXS35EVMA
FTXS50FVMA
FTXS60FVMA
FTXS71FVMA
FDXS25CVMA
FDXS35CVMA
FDXS50CVMA
FDXS60CVMA
CDXS25EAVMA
CDXS35EAVMA

FLXS25BVMA
FLXS35BVMA
FLXS50BVMA
FLXS60BVMA
FVXS25FV1A
FVXS35FV1A
FVXS50FV1A
FFQ25B8V1B
FFQ35B8V1B
FFQ50B8V1B
FFQ60B8V1B

3MXS52EVMA
3MXS68EVMA
4MXS80EVMA

1. Power Supply ........................................................................................11


2. Functions...............................................................................................12
3. Specifications ........................................................................................16
3.1 Indoor Units ............................................................................................16
3.2 Outdoor Units .........................................................................................22
3.3 Combination Capacity ............................................................................24

4. Dimensions ...........................................................................................42
4.1 Indoor Units ............................................................................................42
4.2 Outdoor Units .........................................................................................51

5. Wiring Diagrams....................................................................................53
5.1 Indoor Units ............................................................................................53
5.2 Outdoor Units .........................................................................................57

6. Piping Diagrams....................................................................................59
6.1 Indoor Units ............................................................................................59
6.2 Outdoor Units .........................................................................................63

7. Capacity Tables ....................................................................................65


7.1 Total Capacity ........................................................................................65
7.2 Capacity Correction Factor by the Length of Refrigerant Piping
(Reference) ..........................................................................................165
SUPER MULTI NX E-Series Heat Pump

EDAU12-722

8. Operation Limit....................................................................................166
9. Fan Characteristics .............................................................................167
9.1 External Static Pressure.......................................................................167

10.Sound Level ........................................................................................170


10.1 Measuring Location ..............................................................................170
10.2 Octave Band Level ...............................................................................171

11.Electric Characteristics........................................................................177

10

SUPER MULTI NX E-Series Heat Pump

EDAU12-722

Power Supply

1. Power Supply
Indoor Unit
Wall Mounted Type

FTXS20DVMA
FTXS25EVMA

Outdoor Unit

Power Supply

3MXS52EVMA
3MXS68EVMA
4MXS80EVMA

1, 220-240V, 50Hz
1, 220-230V, 60Hz

FTXS35EVMA
FTXS50FVMA
FTXS60FVMA
FTXS71FVMA
Duct Connected Type

FDXS25CVMA
FDXS35CVMA
FDXS50CVMA
FDXS60CVMA
CDXS25EAVMA
CDXS35EAVMA

Floor / Ceiling Suspended


Dual Type

FLXS25BVMA
FLXS35BVMA
FLXS50BVMA
FLXS60BVMA

Floor Standing Type

FVXS25FV1A
FVXS35FV1A
FVXS50FV1A

Ceiling Mounted Cassette


Type

FFQ25B8V1B
FFQ35B8V1B
FFQ50B8V1B
FFQ60B8V1B

Note:

Power Supply Intake ; Outdoor Unit

SUPER MULTI NX E-Series Heat Pump

11

Functions

EDAU12-722

Basic
Function

Operation Limit for Cooling (CDB)

Compressor

Comfortable
Airflow

Comfort
Control

Operation

Lifestyle
Convenience

Functions

FTXS50-71FVMA

FTXS50-71FVMA

Inverter (with Inverter Power


Control)

Category

FTXS20DVMA
FTXS25/35EVMA

FTXS20DVMA
FTXS25/35EVMA

2. Functions

Air Purifying Filter with


Bacteriostatic & Virustatic
Functions

Photocatalytic Deodorizing Filter

Category

Health &
Clean

Functions

Operation Limit for Heating (CWB)

Air Purifying Filter with


Photocatalytic Deodorizing
Function

PAM Control

Titanium Apatite Photocatalytic


Air-Purifying Filter

Oval Scroll Compressor

Longlife Filter (Option)

Swing Compressor

Mold Proof Air Filter

Rotary Compressor

Wipe-clean Flat Panel

Reluctance DC Motor

Washable Grille

Power-Airflow Flap

Filter Cleaning Indicator

Power-Airflow Dual Flaps

Mold Proof Operation

Power-Airflow Diffuser

Heating Dry Operation

Wide-Angle Louvers

Good-Sleep Cooling Operation

Vertical Auto-Swing (Up and


Down)

Weekly Timer

Horizontal Auto-Swing (Right and


Left)

24-Hour On/Off Timer

3-D Airflow

Comfort Airflow Mode

Timer

Worry Free
Reliability &
Durability

Night Set Mode

Auto-Restart (after Power Failure)

Self-Diagnosis (Digital, LED)


Display

3-Step Airflow (H/P Only)

Auto Fan Speed

Wiring-Error Check

Anticorrosion Treatment of
Outdoor Heat Exchanger

Multi-Split / Split Type Compatible


Indoor Unit

Indoor Unit Quiet Operation

Night Quiet Mode (Automatic)

Outdoor Unit Quiet Operation


(Manual)

Flexible Voltage Correspondence

Flexibility

Intelligent Eye

High Ceiling Application

Quick Warming Function

Chargeless

Hot-Start Function

Either Side Drain (Right or left)

Automatic Defrosting

Power-Selection

Automatic Operation

5-Rooms Centralized Controller


(Option)

Programme Dry Function

Remote Control Adaptor


(Normal Open-Pulse Contact)
(Option)

Fan Only

Remote Control Adaptor


(Normal Open Contact) (Option)

New Powerful Operation


(Non-Inverter)

Dlll-NET Compatible (Adaptor)


(Option)

Inverter Powerful Operation

Priority-Room Setting

Cooling / Heating Mode Lock

Home Leave Operation

ECONO Mode

Indoor Unit On/Off Switch

Signal Reception Indicator

Temperature Display

Another Room Operation

Remote
Control

Remote
Controller

Wireless

Wired

Note: { : Holding Functions


: No Functions

12

SUPER MULTI NX E-Series Heat Pump

Basic
Function

Operation Limit for Cooling (CDB)

Compressor

Comfortable
Airflow

Comfort
Control

Operation

Lifestyle
Convenience

Functions

CDXS25/35EAVMA

Inverter (with Inverter Power


Control)

Category

FDXS25-60CVMA

CDXS25/35EAVMA

Functions

FDXS25-60CVMA

EDAU12-722

Air Purifying Filter with


Bacteriostatic & Virustatic
Functions

Photocatalytic Deodorizing Filter

Category

Health &
Clean

Functions

Operation Limit for Heating (CWB)

Air Purifying Filter with


Photocatalytic Deodorizing
Function

PAM Control

Titanium Apatite Photocatalytic


Air-Purifying Filter

Oval Scroll Compressor

Longlife Filter (Option)

Swing Compressor

Mold Proof Air Filter

Rotary Compressor

Wipe-clean Flat Panel

Reluctance DC Motor

Washable Grille

Power-Airflow Flap

Filter Cleaning Indicator

Power-Airflow Dual Flaps

Mold Proof Operation

Power-Airflow Diffuser

Heating Dry Operation

Wide-Angle Louvers

Good-Sleep Cooling Operation

Weekly Timer

24-Hour On/Off Timer

Night Set Mode

Auto-Restart (after Power Failure)

Self-Diagnosis (Digital, LED)


Display

Vertical Auto-Swing (Up and


Down)

Timer

Horizontal Auto-Swing (Right and


Left)

3-D Airflow

Comfort Airflow Mode

3-Step Airflow (H/P Only)

Auto Fan Speed

Wiring-Error Check

Anticorrosion Treatment of
Outdoor Heat Exchanger

Multi-Split / Split Type Compatible


Indoor Unit

Worry Free
Reliability &
Durability

Indoor Unit Quiet Operation

Night Quiet Mode (Automatic)

Outdoor Unit Quiet Operation


(Manual)

Flexible Voltage Correspondence

Intelligent Eye

High Ceiling Application

Quick Warming Function

Chargeless

Hot-Start Function

Either Side Drain (Right or left)

Automatic Defrosting

Flexibility

Remote
Control

Power-Selection

5-Rooms Centralized Controller


(Option)

Automatic Operation

Programme Dry Function

Remote Control Adaptor


(Normal Open-Pulse Contact)
(Option)

Fan Only

Remote Control Adaptor


(Normal Open Contact) (Option)

New Powerful Operation


(Non-Inverter)

Dlll-NET Compatible (Adaptor)


(Option)

Inverter Powerful Operation

Priority-Room Setting

Cooling / Heating Mode Lock

Home Leave Operation

ECONO Mode

Indoor Unit On/Off Switch

Signal Reception Indicator

Temperature Display

Another Room Operation

Remote
Controller

Wireless

Wired

Note: { : Holding Functions


: No Functions

SUPER MULTI NX E-Series Heat Pump

13

Compressor

Comfortable
Airflow

Comfort
Control

Operation

Lifestyle
Convenience

Operation Limit for Cooling (CDB)

Air Purifying Filter with


Bacteriostatic & Virustatic
Functions

Photocatalytic Deodorizing Filter

Category

Health &
Clean

Functions

Operation Limit for Heating (CWB)

Air Purifying Filter with


Photocatalytic Deodorizing
Function

PAM Control

Titanium Apatite Photocatalytic


Air-Purifying Filter

Oval Scroll Compressor

Longlife Filter (Option)

Swing Compressor

Mold Proof Air Filter

Rotary Compressor

Wipe-clean Flat Panel

Reluctance DC Motor

Washable Grille

Power-Airflow Flap

Filter Cleaning Indicator

Power-Airflow Dual Flaps

Mold Proof Operation

Power-Airflow Diffuser

Heating Dry Operation

Wide-Angle Louvers

Good-Sleep Cooling Operation

Weekly Timer

24-Hour On/Off Timer

Vertical Auto-Swing (Up and


Down)

Horizontal Auto-Swing (Right and


Left)

3-D Airflow

Comfort Airflow Mode

Timer

Worry Free
Reliability &
Durability

Night Set Mode

Auto-Restart (after Power Failure)

Self-Diagnosis (Digital, LED)


Display

3-Step Airflow (H/P Only)

Auto Fan Speed

Wiring-Error Check

Anticorrosion Treatment of
Outdoor Heat Exchanger

Multi-Split / Split Type Compatible


Indoor Unit

Indoor Unit Quiet Operation

Night Quiet Mode (Automatic)

Outdoor Unit Quiet Operation


(Manual)

Flexible Voltage Correspondence

Intelligent Eye

High Ceiling Application

Quick Warming Function

Chargeless

Hot-Start Function

Either Side Drain (Right or Left)

Automatic Defrosting

Power-Selection

Automatic Operation

5-Rooms Centralized Controller


(Option)

Programme Dry Function

Remote Control Adaptor


(Normal Open-Pulse Contact)
(Option)

Fan Only

Remote Control Adaptor


(Normal Open Contact) (Option)

New Powerful Operation


(Non-Inverter)

Dlll-NET Compatible (Adaptor)


(Option)

Inverter Powerful Operation

Wireless

Wired

Priority-Room Setting

Cooling / Heating Mode Lock

Home Leave Operation

ECONO Mode

Indoor Unit On/Off Switch

Signal Reception Indicator

Temperature Display

Another Room Operation

Note: { : Holding Functions


: No Functions

14

FFQ25-60B8V1B

Basic
Function

Functions

FVXS25-50FV1A

FFQ25-60B8V1B

Inverter (with Inverter Power


Control)

Category

FLXS25-60BVMA

FVXS25-50FV1A

EDAU12-722

FLXS25-60BVMA

Functions

Flexibility

Remote
Control

Remote
Controller

: 72-Hour On/Off Timer

SUPER MULTI NX E-Series Heat Pump

3MXS52EVMA
3MXS68EVMA

4MXS80EVMA

4MXS80EVMA

Functions

3MXS52EVMA
3MXS68EVMA

EDAU12-722

Inverter (with Inverter Power


Control)

Air Purifying Filter with


Bacteriostatic & Virustatic
Functions

Operation Limit for Cooling (CDB)

5
~
46

10
~
46

Photocatalytic Deodorizing Filter

Operation Limit for Heating (CWB)

15
~
15.5

15
~
15.5

Air Purifying Filter with


Photocatalytic Deodorizing
Function

PAM Control

Titanium Apatite Photocatalytic


Air-Purifying Filter

Category

Basic
Function

Compressor

Comfortable
Airflow

Comfort
Control

Operation

Lifestyle
Convenience

Functions

Category

Health &
Clean

Functions

Oval Scroll Compressor

Longlife Filter (Option)

Swing Compressor

Mould Proof Air Filter

Rotary Compressor

Wipe-clean Flat Panel

Reluctance DC Motor

Washable Grille

Power-Airflow Flap

Filter Cleaning Indicator

Power-Airflow Dual Flaps

Mold Proof Operation

Power-Airflow Diffuser

Heating Dry Operation

Wide-Angle Louvers

Good-Sleep Cooling Operation

Weekly Timer

24-Hour On/Off Timer

Vertical Auto-Swing (Up and


Down)

Horizontal Auto-Swing (Right and


Left)

3-D Airflow

Comfort Airflow Mode

3-Step Airflow (H/P Only)

Auto Fan Speed

Timer

Night Set Mode

Auto-Restart (after Power Failure)

Self-Diagnosis (Digital, LED)


Display

Wiring-Error Check

Anticorrosion Treatment of
Outdoor Heat Exchanger

Multi-Split / Split Type Compatible


Indoor Unit

Flexible Voltage Correspondence

Worry Free
Reliability &
Durability

Indoor Unit Quiet Operation

Night Quiet Mode (Automatic)

Outdoor Unit Quiet Operation


(Manual)

Intelligent Eye

High Ceiling Application

Quick Warming Function

Chargeless

Hot-Start Function

Either Side Drain (Right or Left)

Automatic Defrosting

Power-Selection

Automatic Operation

5-Rooms Centralized Controller


(Option)

Programme Dry Function

Remote Control Adaptor


(Normal Open-Pulse Contact)
(Option)

Fan Only

Remote Control Adaptor


(Normal Open Contact) (Option)

New Powerful Operation


(Non-Inverter)

Dlll-NET Compatible (Adaptor)


(Option)

Inverter Powerful Operation

Priority-Room Setting

Cooling / Heating Mode Lock

Home Leave Operation

ECONO Mode

Indoor Unit On/Off Switch

Signal Reception Indicator

Temperature Display

Another Room Operation

Flexibility

Remote
Control

Remote
Controller

30m

40m

Wireless

Wired

Note: { : Holding Functions


: No Functions

SUPER MULTI NX E-Series Heat Pump

15

Specifications

EDAU12-722

3. Specifications
3.1

Indoor Units

Wall Mounted Type

50Hz 220-230-240V / 60Hz 220-230V


FTXS20DVMA

Model

Cooling

m/min
(cfm)

Type
Motor Output
Speed
Air Direction Control
Air Filter
Running Current (Rated)
Power Consumption (Rated)
Power Factor
Temperature Control
Dimensions (HWD)
Packaged Dimensions (HWD)
Weight
Gross Weight
Operation
H/M/L/SL
Sound
Heat Insulation
Liquid
Piping Connection
Gas
Drain
Drawing No.
Fan

H
M
L
SL
W
Steps

A
W
%
mm
mm
kg
kg
dBA

8.7 (307)
6.7 (237)
4.7 (166)
3.9 (138)

37//28/25

8.7 (307)
6.7 (237)
4.7 (166)
3.9 (138)

37/31/25/22

FTXS50FVMA
Heating

Cooling

3.5kW Class
White
m/min
(cfm)

Type
Motor Output
Speed
Air Direction Control
Air Filter
Running Current (Rated)
Power Consumption (Rated)
Power Factor
Temperature Control
Dimensions (HWD)
Packaged Dimensions (HWD)
Weight
Gross Weight
Operation
H/M/L/SL
Sound
Sound Power H
Heat Insulation
Liquid
Piping Connection
Gas
Drain
Drawing No.

H
M
L
SL
W
Steps

A
W
%
mm
mm
kg
kg

8.9 (314)
6.9 (242)
4.8 (169)
4.0 (141)

37/33/28/25

Both Liquid and Gas Pipes


6.4
9.5
18.0
3D054406A

FTXS35EVMA
Cooling

9.4 (332)
7.6 (268)
5.8 (205)
5.0 (177)

Cross Flow Fan


40
5 Steps, Quiet, Auto
Right, Left, Horizontal, Downward
Removable-Washable-Mildew Proof
0.17-0.16-0.15/0.17-0.16
0.17-0.16-0.15/0.17-0.16
35
35
93.6-95.1-97.2/93.6-95.1
93.6-95.1-97.2/93.6-95.1
Microcomputer Control
283800195
265855340
9
12

Both Liquid and Gas Pipes


6.4
9.5
18.0
3D049290

Rated Capacity
Front Panel Color

Fan

9.4 (332)
7.6 (268)
5.8 (205)
5.0 (177)

37//25/22

Heating
2.5kW Class
White

Cross Flow Fan


40
5 Steps, Quiet, Auto
Right, Left, Horizontal, Downward
Removable-Washable-Mildew Proof
0.17-0.16-0.15/0.17-0.16
0.17-0.16-0.15/0.17-0.16
35
35
93.6-95.1-97.2/93.6-95.1
93.6-95.1-97.2/93.6-95.1
Microcomputer Control
283800195
265855340
9
12

mm
mm
mm

Model

Air Flow Rates

Cooling

2.0kW Class
White

Rated Capacity
Front Panel Color
Air Flow Rates

FTXS25EVMA
Heating

Heating
5.0kW Class
White

9.7 (342)
7.9 (277)
6.0 (212)
5.2 (184)

Cross Flow Fan


40
5 Steps, Quiet, Auto
Right, Left, Horizontal, Downward
Removable-Washable-Mildew Proof
0.19-0.18-0.17/0.19-0.18
0.19-0.18-0.17/0.19-0.18
40
40
95.7-96.6-98.0/95.7-96.6
95.7-96.6-98.0/95.7-96.6
Microcomputer Control
283800195
265855340
9
12

14.7 (519)
12.6 (445)
10.2 (360)
9.2 (325)

16.2 (572)
13.8 (487)
11.5 (406)
10.2 (360)

Cross Flow Fan


43
5 Steps, Quiet, Auto
Right, Left, Horizontal, Downward
Removable-Washable-Mildew Proof
0.16-0.15-0.15/0.16-0.15
0.17-0.16-0.16/0.17-0.16
34
36
96.6-98.6-94.4/96.6-98.6
96.3-97.8-93.8/96.3-97.8
Microcomputer Control
2901,050238
3371,147366
12
17

dBA

38/32/26/23

38/34/29/26

44/40/35/32

42/38/33/30

dBA

60

58

mm
mm
mm

Both Liquid and Gas Pipes


6.4
9.5
18.0
3D054407A

See Page 24 Combination Capacity.

Both Liquid and Gas Pipes


6.4
12.7
18.0
3D054879

Conversion Formulae
kcal/h=kW860
Btu/h=kW3414
cfm=m/min35.3

16

SUPER MULTI NX E-Series Heat Pump

EDAU12-722

Specifications

50Hz 220-230-240V / 60Hz 220-230V


FTXS60FVMA

Model

Cooling

Cooling

6.0kW Class
White

Rated Capacity
Front Panel Color
m/min
(cfm)

Air Flow Rates

FTXS71FVMA
Heating

Type
Motor Output
Speed
Air Direction Control
Air Filter
Running Current (Rated)
Power Consumption (Rated)
Power Factor
Temperature Control
Dimensions (HWD)
Packaged Dimensions (HWD)
Weight
Gross Weight
Operation
H/M/L/SL
Sound
Sound Power H
Heat Insulation
Liquid
Piping Connection
Gas
Drain
Drawing No.
Fan

H
M
L
SL
W
Steps

A
W
%
mm
mm
kg
kg

16.2 (572)
13.9 (491)
11.5 (406)
10.0 (353)

Heating
7.1kW Class
White

17.4 (614)
15.3 (540)
12.8 (452)
10.5 (371)

Cross Flow Fan


43
5 Steps, Quiet, Auto
Right, Left, Horizontal, Downward
Removable-Washable-Mildew Proof
0.19-0.18-0.17/0.19-0.18
0.21-0.20-0.19/0.21-0.20
40
45
95.7-96.6-98.0/95.7-96.6
97.4-97.8-98.7/97.4-97.8
Microcomputer Control
2901,050238
3371,147366
12
17

17.4 (614)
14.6 (516)
11.9 (420)
11.2 (395)

21.5 (759)
18.0 (636)
14.4 (508)
13.3 (470)

Cross Flow Fan


43
5 Steps, Quiet, Auto
Right, Left, Horizontal, Downward
Removable-Washable-Mildew Proof
0.21-0.20-0.19/0.21-0.20
0.28-0.27-0.26/0.28-0.27
45
60
97.4-97.8-98.7/97.4-97.8
97.4-96.6-96.2/97.4-96.6
Microcomputer Control
2901,050238
3371,147366
12
17

dBA

45/41/36/33

44/40/35/32

46/42/37/34

46/42/37/34

dBA

61

60

62

62

Both Liquid and Gas Pipes


6.4
12.7
18.0
3D054880

mm
mm
mm

Both Liquid and Gas Pipes


6.4
15.9
18.0
3D054881A

Duct Connected Type


50Hz 220-230-240V / 60Hz 220-230V
FDXS25CVMA

Model

Cooling

Fan

Cooling

2.5kW Class

Rated Capacity
Front Panel Color

Type
Motor Output
Speed

Air Filter
Running Current (Rated)
Power Consumption (Rated)
Power Factor
Temperature Control
Dimensions (HWD)
Packaged Dimensions (HWD)
Weight
Gross Weight
Operation
H/M/L/SL
Sound
External Static Pressure
Moisture Removal
Heat Insulation
Liquid
Piping Connection
Gas
Drain
Drawing No.

H
M
L
SL
W
Steps
A
W
%
mm
mm
kg
kg

9.5 (335)
8.8 (311)
8.0 (282)
6.7 (237)

9.5 (335)
8.8 (311)
8.0 (282)
6.7 (237)

Sirocco Fan
62
5 Steps, Quiet, Auto
Removable-Washable-Mildew Proof
0.49-0.47-0.45/0.49-0.47
0.49-0.47-0.45/0.49-0.47
100
100
92.8-92.5-92.6/92.8-92.5
92.8-92.5-92.6/92.8-92.5
Microcomputer Control
200900620
2661,106751
25
31

dBA

35/33/31/29

Pa
L/h

1.2

mm
mm
mm

10.0 (353)
9.3 (328)
8.5 (300)
7.0 (247)

35/33/31/29

35/33/31/29

1.9

Both Liquid and Gas Pipes


6.4
9.5
VP20 (O.D 26 / I.D 20)
3D055393B

10.0 (353)
9.3 (328)
8.5 (300)
7.0 (247)

Sirocco Fan
62
5 Steps, Quiet, Auto
Removable-Washable-Mildew Proof
0.49-0.47-0.45/0.49-0.47
0.49-0.47-0.45/0.49-0.47
100
100
92.8-92.5-92.6/92.8-92.5
92.8-92.5-92.6/92.8-92.5
Microcomputer Control
200900620
2661,106751
25
31

40

See Page 24 Combination Capacity.

Heating
3.5kW Class

m/min
(cfm)

Air Flow Rates

FDXS35CVMA
Heating

35/33/31/29
40

Both Liquid and Gas Pipes


6.4
9.5
VP20 (O.D 26 / I.D 20)
3D055394B

Conversion Formulae
kcal/h=kW860
Btu/h=kW3414
cfm=m/min35.3

SUPER MULTI NX E-Series Heat Pump

17

Specifications

EDAU12-722

50Hz 220-230-240V / 60Hz 220-230V


FDXS50CVMA

Model

Heating

Type
Motor Output
Speed

H
M
L
SL
W
Steps

Air Filter
Running Current (Rated)
Power Consumption (Rated)
Power Factor
Temperature Control
Dimensions (HWD)
Packaged Dimensions (HWD)
Weight
Gross Weight
Operation
H/M/L/SL
Sound
Sound Power
H
External Static Pressure
Heat Insulation
Liquid
Piping Connection
Gas
Drain
Drawing No.

A
W
%
mm
mm
kg
kg

12.0 (424)
11.0 (388)
10.0 (353)
8.4 (297)

Sirocco Fan
130
5 Steps, Quiet, Auto
Removable-Washable-Mildew Proof
0.69-0.66-0.63/0.69-0.66
0.69-0.66-0.63/0.69-0.66
140
140
92.2-92.2-92.6/92.2-92.2
92.2-92.2-92.6/92.2-92.2
Microcomputer Control
200900620
2661,106751
27
34

16.0 (565)
14.8 (523)
13.5 (477)
11.2 (395)

Sirocco Fan
130
5 Steps, Quiet, Auto
Removable-Washable-Mildew Proof
0.80-0.77-0.74/0.80-0.77
0.78-0.75-0.72/0.78-0.75
160
160
90.9-90.3-90.1/90.9-90.3
93.2-92.8-92.6/93.2-92.8
Microcomputer Control
2001,100620
2661,306751
30
37

37/35/33/31

37/35/33/31

38/36/34/32

38/36/34/32

55

55

56

56

mm
mm
mm

40
Both Liquid and Gas Pipes
6.4
12.7
VP20 (O.D 26 / I.D 20)
3D054916A

40
Both Liquid and Gas Pipes
6.4
12.7
VP20 (O.D 26 / I.D 20)
3D054917A

CDXS25EAVMA

CDXS35EAVMA

Cooling

Heating

Cooling

2.5kW Class

Type
Motor Output
Speed

Air Filter
Running Current (Rated)
Power Consumption (Rated)
Power Factor
Temperature Control
Dimensions (HWD)
Packaged Dimensions (HWD)
Weight
Gross Weight
Operation
H/M/L/SL
Sound
External Static Pressure
Moisture Removal
Heat Insulation
Liquid
Piping Connection
Gas
Drain
Drawing No.

H
M
L
SL

8.7 (307)
8.0 (282)
7.3 (258)
6.2 (219)

8.7 (307)
8.0 (282)
7.3 (258)
6.2 (219)
Sirocco Fan
62
5 Steps, Quiet, Auto

W
Steps

A
W
%
mm
mm
kg
kg
dBA
Pa
L/h
mm
mm
mm

0.47-0.48-0.49/0.52-0.53
0.47-0.48-0.49/0.52-0.53
70-71-72/72-73
70-71-72/72-73
67.7-64.3-61.2/62.9-59.9
67.7-64.3-61.2/62.9-59.9
Microcomputer Control
200700620
274906751
21
29
35/33/31/29

35/33/31/29

8.7 (307)
8.0 (282)
7.3 (258)
6.2 (219)

1.2
Both Liquid and Gas Pipes
6.4
9.5
VP20 (O.D 26 / I.D 20)
3D051140

8.7 (307)
8.0 (282)
7.3 (258)
6.2 (219)

Sirocco Fan
62
5 Steps, Quiet, Auto
Removable-Washable-Mildew Proof
0.47-0.48-0.49/0.52-0.53
0.47-0.48-0.49/0.52-0.53
70-71-72/72-73
70-71-72/72-73
67.7-64.3-61.2/62.9-59.9
67.7-64.3-61.2/62.9-59.9
Microcomputer Control
200700620
274906751
21
29
35/33/31/29

30

See Page 24 Combination Capacity.

Heating
3.5kW Class

m/min
(cfm)

16.0 (565)
14.8 (523)
13.5 (477)
11.2 (395)

dBA

Rated Capacity
Front Panel Color

Fan

12.0 (424)
11.0 (388)
10.0 (353)
8.4 (297)

dBA
Pa

Model

Air Flow Rates

Heating
6.0kW Class

m/min
(cfm)

Air Flow Rates

Cooling

5.0kW Class

Rated Capacity
Front Panel Color

Fan

FDXS60CVMA

Cooling

35/33/31/29
30

1.9
Both Liquid and Gas Pipes
6.4
9.5
VP20 (O.D 26 / I.D 20)
3D051141

Conversion Formulae
kcal/h=kW860
Btu/h=kW3414
cfm=m/min35.3

18

SUPER MULTI NX E-Series Heat Pump

EDAU12-722

Specifications

Floor / Ceiling Suspended Dual Type


50Hz 230V
FLXS25BVMA

Model

Cooling

m/min
(cfm)

Type
Motor Output
Speed
Air Direction Control
Air Filter
Running Current (Rated)
Power Consumption (Rated)
Power Factor
Temperature Control
Dimensions (HWD)
Packaged Dimensions (HWD)
Weight
Gross Weight
Operation
H/M/L/SL
Sound
Heat Insulation
Liquid
Piping Connection
Gas
Drain
Drawing No.
Fan

H
M
L
SL
W
Steps

A
W
%
mm
mm
kg
kg
dBA
mm
mm
mm

7.6 (268)
6.8 (240)
6.0 (212)
5.2 (184)

Sirocco Fan
34
5 Steps, Quiet, Auto
Right, Left, Horizontal, Downward
Removable-Washable-Mildew Proof
0.32
0.34
70
74
95.1
94.6
Microcomputer Control
4901,050200
2801,100566
16
22
37/34/31/29

Both Liquid and Gas Pipes


6.4
9.5
18.0
3D046600

Cooling

8.6 (304)
7.6 (268)
6.6 (233)
5.6 (198)

m/min
(cfm)

Type
Motor Output
Speed
Air Direction Control
Air Filter
Running Current (Rated)
Power Consumption (Rated)
Power Factor
Temperature Control
Dimensions (HWD)
Packaged Dimensions (HWD)
Weight
Gross Weight
Operation
H/M/L/SL
Sound
Heat Insulation
Liquid
Piping Connection
Gas
Drain
Drawing No.

H
M
L
SL
W
Steps

A
W
%
mm
mm
kg
kg
dBA
mm
mm
mm

11.4 (402)
10.0 (353)
8.5 (300)
7.5 (265)

38/35/32/29

Cooling

Heating
5.7kW Class
Almond White

12.1 (427)
9.8 (346)
7.5 (265)
6.8 (240)

46/41/35/33

Both Liquid and Gas Pipes


6.4
12.7
18.0
3D046571

See Page 24 Combination Capacity.

39/36/33/30

Both Liquid and Gas Pipes


6.4
9.5
18.0
3D046601

FLXS60BVMA
Heating

Sirocco Fan
34
5 Steps, Quiet, Auto
Right, Left, Horizontal, Downward
Removable-Washable-Mildew Proof
0.45
0.45
96
96
92.8
92.8
Microcomputer Control
4901,050200
2801,100566
17
24
47/43/39/36

9.8 (346)
8.9 (314)
8.0 (282)
7.2 (254)

Sirocco Fan
34
5 Steps, Quiet, Auto
Right, Left, Horizontal, Downward
Removable-Washable-Mildew Proof
0.36
0.36
78
78
94.2
94.2
Microcomputer Control
4901,050200
2801,100566
16
22

5.0kW Class
Almond White

Rated Capacity
Front Panel Color

Fan

9.2 (325)
8.3 (293)
7.4 (261)
6.6 (233)

37/34/31/28

Heating
3.5kW Class
Almond White

FLXS50BVMA

Model

Air Flow Rates

Cooling

2.5kW Class
Almond White

Rated Capacity
Front Panel Color
Air Flow Rates

FLXS35BVMA
Heating

12.0 (424)
10.7 (378)
9.3 (328)
8.3 (293)

12.8 (452)
10.6 (374)
8.4 (297)
7.5 (265)

Sirocco Fan
34
5 Steps, Quiet, Auto
Right, Left, Horizontal, Downward
Removable-Washable-Mildew Proof
0.47
0.45
98
96
90.7
92.8
Microcomputer Control
4901,050200
2801,100566
17
24
48/45/41/39

47/42/37/34

Both Liquid and Gas Pipes


6.4
12.7
18.0
3D046572

Conversion Formulae
kcal/h=kW860
Btu/h=kW3414
cfm=m/min35.3

SUPER MULTI NX E-Series Heat Pump

19

Specifications

EDAU12-722

Floor Standing Type


550Hz 220-230-240V
FVXS25FV1A

Model

Cooling

m/min
(cfm)

Type
Motor Output
Speed
Air Direction Control
Air Filter
Running Current (Rated)
Power Consumption (Rated)
Power Factor
Temperature Control
Dimensions (HWD)
Packaged Dimensions (HWD)
Weight
Gross Weight
Operation
H/M/L/SL
Sound
Sound Power H
Heat Insulation
Liquid
Piping Connection
Gas
Drain
Drawing No.
Fan

H
M
L
SL
W
Steps

A
W
%
mm
mm
kg
kg

8.2 (290)
6.5 (229)
4.8 (169)
4.1 (146)

8.8 (311)
6.9 (244)
5.0 (178)
4.4 (155)

8.5 (300)
6.7 (237)
4.9 (174)
4.5 (158)

9.4 (332)
7.3 (258)
5.2 (184)
4.7 (168)

Turbo Fan
48
5 Steps, Quiet, Auto
Right, Left, Horizontal, Downward
Removable-Washable-Mildew Proof
0.14-0.13-0.12
0.15-0.14-0.13
15
17
48.7-50.2-52.1
51.5-52.8-54.5
Microcomputer Control
600700210
696786280
14
18

dBA

38/32/26/23

38/32/26/23

39/33/27/24

39/33/27/24

dBA

54

54

55

55

mm
mm
mm

Both Liquid and Gas Pipes


6.4
9.5
20.0
C : 3D056271

Both Liquid and Gas Pipes


6.4
9.5
20.0
C : 3D056272

FVXS50FV1A
Cooling

Heating
5.0kW Class
White

Rated Capacity
Front Panel Color
m/min
(cfm)

Type
Motor Output
Speed
Air Direction Control
Air Filter
Running Current (Rated)
Power Consumption (Rated)
Power Factor
Temperature Control
Dimensions (HWD)
Packaged Dimensions (HWD)
Weight
Gross Weight
Operation
H/M/L/SL
Sound
Sound Power H
Heat Insulation
Liquid
Piping Connection
Gas
Drain
Drawing No.
Fan

Heating
3.5kW Class
White

Turbo Fan
48
5 Steps, Quiet, Auto
Right, Left, Horizontal, Downward
Removable-Washable-Mildew Proof
0.14-0.13-0.12
0.15-0.14-0.13
15
17
48.7-50.2-52.1
51.5-52.8-54.5
Microcomputer Control
600700210
696786280
14
18

Model

Air Flow Rates

Cooling

2.5kW Class
White

Rated Capacity
Front Panel Color
Air Flow Rates

FVXS35FV1A
Heating

H
M
L
SL

10.7 (378)
9.2 (326)
7.8 (274)
6.6 (233)
Turbo Fan
48
5 Steps, Quiet, Auto
Right, Left, Horizontal, Downward
Removable-Washable-Mildew Proof

W
Steps

A
W
%

0.18-0.17-0.16
27
68.1-69.1-70.3

dBA

44/40/36/32

dBA

56

See Page 24 Combination Capacity.

0.20-0.19-0.18
34
77.3-77.8-78.7
Microcomputer Control
600700210
696786280
14
18

mm
mm
kg
kg

mm
mm
mm

11.8 (417)
10.1 (358)
8.5 (300)
7.1 (250)

45/40/36/32
57
Both Liquid and Gas Pipes
6.4
12.7
20.0
C : 3D056273

Conversion Formulae
kcal/h=kW860
Btu/h=kW3414
cfm=m/min35.3

20

SUPER MULTI NX E-Series Heat Pump

EDAU12-722

Specifications

Ceiling Mounted Cassette Type


50Hz 230V
FFQ25B8V1B

Model

Cooling

Rated Capacity 1
Color
Decoration
Panel
Dimensions (HWD)
Air Flow Rates

m/min
(cfm)

Type
Fan
Motor Output
Speed
Air Direction Control
Air Filter
Running Current (Rated)
Power Consumption (Rated)
Power Factor
Temperature Control
Dimensions (HWD) 2
Packaged Dimensions (HWD)
Weight
Gross Weight
Operation
H/L
Sound
Sound Power H
Heat Insulation
Liquid
Piping Connection
Gas
Drain
Drawing No.

FFQ35B8V1B
Heating

Cooling

2.5kW Class
White
55700700
H
M
L
SL

9.0 (318)

9.0 (318)

10.0 (353)

10.0 (353)

6.5 (230)

6.5 (230)

6.5 (230)

6.5 (230)

Turbo Fan
55
2 Steps
Horizontal, Downward

W
Steps

dBA
dBA
mm
mm
mm

0.37
73
85.8

0.32
64
87.0

0.40
84
91.3

Microcomputer Control
260(286)575575
370687674
17.5
21

mm
mm
kg
kg

29.5/24.5

Turbo Fan
55
2 Steps
Horizontal, Downward

A
W
%

Heating
3.5kW Class
White
55700700

0.36
76
91.8
Microcomputer Control
260(286)575575
370687674
17.5
21

29.5/24.5

46.5

Both Liquid and Gas Pipes


6.4
9.5
VP20 (O.D 26 / I.D 20)
3D040445

32.0/25.0

32.0/25.0

49.0

Both Liquid and Gas Pipes


6.4
9.5
VP20 (O.D 26 / I.D 20)
3D040443

50Hz 240V
FFQ50B8V1B

Model

Cooling

Rated Capacity 1
Color
Decoration
Panel
Dimensions (HWD)
Air Flow Rates

m/min
(cfm)

Type
Fan
Motor Output
Speed
Air Direction Control
Air Filter
Running Current (Rated)
Power Consumption (Rated)
Power Factor
Temperature Control
Dimensions (HWD) 2
Packaged Dimensions (HWD)
Weight
Gross Weight
Operation
H/L
Sound
Sound Power H
Heat Insulation
Liquid
Piping Connection
Gas
Drain
Drawing No.

FFQ60B8V1B
Heating

Cooling

5.0kW Class
White
55700700
H
M
L
SL

13.0 (459)

13.0 (459)

15.5 (547)

8.0 (283)

8.0 (283)

11.0 (388)

11.0 (388)

Turbo Fan
55
2 Steps
Horizontal, Downward

W
Steps

mm
mm
kg
kg
dBA
dBA
mm
mm
mm

0.46
109
98.7
Microcomputer Control
260(286)575575
370687674
17.5
21
38.0/28.0

55.0

Both Liquid and Gas Pipes


6.4
12.7
VP20 (O.D 26 / I.D 20)
3D040440

1 See Page 24 Combination Capacity.


2 ( ) : dimension including control box

SUPER MULTI NX E-Series Heat Pump

0.51
117
95.6

38.0/28.0

15.5 (547)

Turbo Fan
55
2 Steps
Horizontal, Downward

A
W
%

Heating
6.0kW Class
White
55700700

0.63
140
92.6

0.57
131
95.8
Microcomputer Control
260(286)575575
370687674
17.5
21

42.0/34.0

42.0/34.0

59.0

Both Liquid and Gas Pipes


6.4
12.7
VP20 (O.D 26 / I.D 20)
3D040435

Conversion Formulae
kcal/h=kW860
Btu/h=kW3414
cfm=m/min35.3

21

Specifications

3.2

EDAU12-722

Outdoor Units
50Hz 230-240V
3MXS52EVMA

Model

Cooling

W
L

m/min
Air Flow Rates
cfm

Fan

Type
Motor Output
Running Current
Power Consumption

Starting Current
Dimensions (HWD)
Packaged Dimensions (HWD)
Weight
Gross Weight
Operation Sound
Sound Power
Liquid
Piping Connection
Gas
Drain
Heat Insulation
No. of Wiring Connection
Max. Interunit Piping Length
Amount of Additional Charge
Max. Installation Height Difference
Drawing No.

Note:

kg
H
L
H
L
W
A
W
A
mm
mm
kg
kg
dBA
dBA
mm
mm
mm

m
m
g/m
m
m

Cooling

Heating

Ivory White
Hermetically Sealed Swing Type
2YC36BXD
1,100
FVC50K
0.65
R-410A
2.0
45
45
45
43
1,589
1,589
1,589
1,518
Propeller
53
H: 0.33 / L: 0.33
H: 0.33 / L: 0.31
H: 43 / L: 43
H: 43 / L: 41
6.3
735936300
792992390
49
56
46
47
59
60
6.43
9.52, 12.71
18.0
Both Liquid and Gas Pipes
3 for Power Supply, 4 for Interunit Wiring
50 (for Total of Each Room)
25 (for One Room)
20 (30m or more)
15 (between Indoor Unit and Outdoor Unit)
7.5 (between Indoor Units)
3D055012

Ivory White
Hermetically Sealed Swing Type
2YC45BXD
1,380
FVC50K
0.75
R-410A
2.6
51
47.6
45
45
1,801
1,681
1,589
1,589
Propeller
53
H: 0.33 / L: 0.25
H: 0.31 / L: 0.25
H: 68 / L: 46
H: 63 / L: 46
9.0
735936300
792992390
59
64
48
49
61
62
6.43
12.73
18.0
Both Liquid and Gas Pipes
3 for Power Supply, 4 for Interunit Wiring
60 (for Total of Each Room)
25 (for One Room)
20 (30m or more)
15 (between Indoor Unit and Outdoor Unit)
7.5 (between Indoor Units)
3D055072

1.
See Page 24 Combination Capacity.
2. The data are based on the conditions shown in the table below.
Cooling
Heating
Indoor ; 27CDB/19CWB
Outdoor ; 35CDB

22

Heating

kW
W
A

Cooling Capacity
Power Consumption
Running Current
Casing Color
Type
Compressor
Model
Motor Output
Model
Refrigerant Oil
Charge
Type
Refrigerant
Charge

3MXS68EVMA

Indoor ; 20CDB
Outdoor ; 7CDB/6CWB

Conversion Formulae
Piping Length
7.5m

kcal/h=kW860
Btu/h=kW3414
cfm=m/min35.3

SUPER MULTI NX E-Series Heat Pump

EDAU12-722

Specifications

50Hz 220-230-240V / 60Hz 220-230V


4MXS80EVMA

Model

Cooling

Air Flow Rates


cfm
Type
Motor Output
Running Current
Power Consumption

Starting Current
Dimensions (HWD)
Packaged Dimensions (HWD)
Weight
Gross Weight
Operation Sound
Sound Power
Liquid
Piping Connection
Gas
Drain
Heat Insulation
No. of Wiring Connection
Max. Interunit Piping Length
Amount of Additional Charge
Max. Installation Height Difference

kg
H
L
H
L
W
A
W
A
mm
mm
kg
kg
dBA
dBA
mm
mm
mm

m
m
g/m
m
m

Drawing No.

Note:

Ivory White
Hermetically Sealed Swing Type
2YC63BXD
1,920
FVC50K
0.75
R-410A
3.1

m/min

Fan

Heating

kW
W
A

Cooling Capacity
Power Consumption
Running Current
Casing Color
Type
Compressor
Model
Motor Output
Model
Refrigerant Oil
Charge
Type
Refrigerant
Charge

54.5
46.0
1,924
1,624

46.0
14.7
1,624
519
Propeller
66

H: 0.97 / L: 0.69
H: 86 / L: 55

H: 0.69 / L: 0.55
H: 55 / L: 9
9.7
770900320
900925390
72
81

48
61

6.44
9.51, 12.71, 15.92
25

SUPER MULTI NX E-Series Heat Pump

49
62

Both Liquid and Gas Pipes


3 for Power Supply, 4 for Interunit Wiring
70 (for Total of Each Room)
25 (for One Room)
20 (40m or more)
15 (between Indoor Unit and Outdoor Unit)
7.5 (between Indoor Units)
3D052664#1

1.
See Page 24 Combination Capacity.
2. The data are based on the conditions shown in the table below.
Cooling
Heating
Indoor ; 27CDB/19CWB
Outdoor ; 35CDB

Indoor ; 20CDB
Outdoor ; 7CDB/6CWB

Conversion Formulae
Piping Length
7.5m

kcal/h=kW860
Btu/h=kW3414
cfm=m/min35.3

23

Specifications

EDAU12-722

3.3

Combination Capacity

3.3.1

3MXS52EVMA

Cooling [50Hz 230V]


Capacity of each indoor unit
Combination of
indoor unit
2.0
2.5
3.5
5.0
2.0+2.0
2.0+2.5
2.0+3.5
2.0+5.0
2.5+2.5
2.5+3.5
2.5+5.0
3.5+3.5
3.5+5.0
2.0+2.0+2.0
2.0+2.0+2.5
2.0+2.0+3.5
2.0+2.5+2.5
2.0+2.5+3.5
2.0+3.5+3.5
2.5+2.5+2.5
2.5+2.5+3.5
2.0+2.0+5.0

Each capacity (kW)


A room
2.00
2.50
3.50
5.00
2.00
2.00
1.89
1.49
2.50
2.17
1.73
2.60
2.14
1.73
1.60
1.38
1.49
1.30
1.16
1.73
1.53
1.16

B room

2.00
2.50
3.31
3.71
2.50
3.03
3.47
2.60
3.06
1.73
1.60
1.38
1.85
1.63
2.02
1.73
1.53
1.16

C room

1.73
1.99
2.43
1.85
2.27
2.02
1.73
2.14
2.88

Total capacity (kW)


Rating
2.00
2.50
3.50
5.00
4.00
4.50
5.20
5.20
5.00
5.20
5.20
5.20
5.20
5.19
5.19
5.19
5.19
5.20
5.20
5.19
5.20
5.20

(min ~ max)
1.76~2.84
1.76~3.24
1.76~4.52
1.85~5.80
1.88~5.96
1.88~6.23
1.88~6.24
1.88~6.91
1.88~6.23
1.88~6.35
1.88~6.91
1.88~6.40
1.88~6.92
1.86~7.04
1.86~7.04
1.95~7.06
1.86~7.04
1.95~7.06
1.95~7.07
1.95~7.04
1.95~7.06
2.04~7.30

Total input (kW)


Rating
0.46
0.62
0.97
1.54
0.95
1.18
1.55
1.28
1.45
1.55
1.28
1.55
1.26
1.24
1.24
1.24
1.24
1.24
1.24
1.24
1.23
1.22

(min ~ max)
0.35~0.74
0.35~0.80
0.35~1.51
0.35~2.10
0.35~1.91
0.35~2.14
0.35~2.14
0.35~2.07
0.35~2.14
0.35~2.25
0.35~2.07
0.35~2.25
0.35~2.08
0.35~2.16
0.35~2.16
0.37~2.16
0.35~2.16
0.37~2.16
0.37~2.16
0.37~2.16
0.37~2.16
0.39~2.19

Total current (A)


Rating
2.1
2.8
4.3
6.8
4.2
5.2
6.8
5.6
6.4
6.8
5.6
6.8
5.6
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4

(min ~ max)
1.6~3.4
1.6~3.6
1.6~6.7
1.5~9.2
1.5~8.4
1.5~9.4
1.5~9.4
1.5~9.1
1.5~9.4
1.5~9.9
1.5~9.1
1.5~9.9
1.5~9.2
1.5~9.5
1.5~9.5
1.6~9.5
1.5~9.5
1.6~9.5
1.6~9.5
1.6~9.5
1.6~9.5
1.7~9.6

Power
factor (%)
Rating
96
97
98
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99

Heating [50Hz 230V]


Capacity of each indoor unit
Combination of
indoor unit
2.0
2.5
3.5
5.0
2.0+2.0
2.0+2.5
2.0+3.5
2.0+5.0
2.5+2.5
2.5+3.5
2.5+5.0
3.5+3.5
3.5+5.0
2.0+2.0+2.0
2.0+2.0+2.5
2.0+2.0+3.5
2.0+2.5+2.5
2.0+2.5+3.5
2.0+3.5+3.5
2.5+2.5+2.5
2.5+2.5+3.5
2.0+2.0+5.0

Each capacity (kW)


A room
2.72
3.40
4.20
5.80
3.05
2.78
2.38
1.94
3.25
2.79
2.27
3.40
2.80
2.26
2.09
1.80
1.94
1.70
1.52
2.26
2.00
1.51

Note:

B room

3.05
3.47
4.17
4.86
3.25
3.97
4.53
3.40
4.00
2.26
2.09
1.80
2.42
2.13
2.64
2.26
2.00
1.51

C room

2.26
2.60
3.18
2.42
2.97
2.64
2.26
2.80
3.78

Total capacity (kW)


Rating
2.72
3.40
4.20
5.80
6.10
6.25
6.55
6.80
6.50
6.70
6.80
6.80
6.80
6.78
6.78
6.78
6.78
6.80
6.80
6.78
6.80
6.80

(min ~ max)
1.21~3.75
1.21~4.00
1.21~4.82
1.30~6.79
1.28~7.00
1.28~7.00
1.34~7.04
1.36~7.95
1.28~7.00
1.34~7.19
1.42~7.95
1.40~7.22
1.42~7.98
1.34~8.02
1.34~8.02
1.45~8.05
1.34~8.02
1.57~8.05
1.56~8.08
1.45~8.02
1.57~8.05
1.64~8.30

Total input (kW)


Rating
0.72
0.99
1.39
1.74
1.70
1.75
1.86
1.52
1.86
1.93
1.52
1.97
1.52
1.57
1.57
1.56
1.57
1.56
1.56
1.57
1.56
1.42

(min ~ max)
0.30~1.20
0.30~1.26
0.30~1.68
0.30~2.51
0.31~2.28
0.31~2.28
0.31~2.28
0.31~2.22
0.31~2.31
0.31~2.36
0.31~2.22
0.31~2.35
0.31~2.21
0.32~2.14
0.32~2.14
0.32~2.14
0.32~2.14
0.32~2.14
0.32~2.14
0.32~2.14
0.32~2.14
0.32~2.04

Total current (A)


Rating
3.3
4.4
6.2
7.6
7.5
7.7
8.2
6.7
8.2
8.5
6.7
8.7
6.7
6.9
6.9
6.9
6.9
6.9
6.9
6.9
6.9
6.2

(min ~ max)
1.4~5.4
1.3~5.6
1.3~7.5
1.3~11.0
1.4~10.0
1.4~10.0
1.4~10.0
1.4~9.7
1.4~10.1
1.4~10.4
1.4~9.7
1.4~10.3
1.4~9.7
1.4~9.4
1.4~9.4
1.4~9.4
1.4~9.4
1.4~9.4
1.4~9.4
1.4~9.4
1.4~9.4
1.4~9.0

Power
factor (%)
Rating
96
97
98
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99

1. Cooling capacity is based on 27CDB/19CWB (Indoor temperature), 35CDB (Outdoor temperature).


Heating capacity is based on 20CDB (Indoor temperature), 7CDB/6CWB (Outdoor temperature).
2. The total ability of connected indoor units is up to 9.0kW.
3. It is impossible to connect the indoor unit for one room only.
3D055013
3D055015

24

SUPER MULTI NX E-Series Heat Pump

EDAU12-722

Specifications

Cooling [50Hz 240V]


Capacity of each indoor unit
Combination of
indoor unit
2.0
2.5
3.5
5.0
2.0+2.0
2.0+2.5
2.0+3.5
2.0+5.0
2.5+2.5
2.5+3.5
2.5+5.0
3.5+3.5
3.5+5.0
2.0+2.0+2.0
2.0+2.0+2.5
2.0+2.0+3.5
2.0+2.5+2.5
2.0+2.5+3.5
2.0+3.5+3.5
2.5+2.5+2.5
2.5+2.5+3.5
2.0+2.0+5.0

Each capacity (kW)


A room
2.00
2.50
3.50
5.00
2.00
2.00
1.89
1.49
2.50
2.17
1.73
2.60
2.14
1.73
1.60
1.38
1.49
1.30
1.16
1.73
1.53
1.16

B room

2.00
2.50
3.31
3.71
2.50
3.03
3.47
2.60
3.06
1.73
1.60
1.38
1.85
1.63
2.02
1.73
1.53
1.16

C room

1.73
1.99
2.43
1.85
2.27
2.02
1.73
2.14
2.88

Total capacity (kW)


Rating
2.00
2.50
3.50
5.00
4.00
4.50
5.20
5.20
5.00
5.20
5.20
5.20
5.20
5.19
5.19
5.19
5.19
5.20
5.20
5.19
5.20
5.20

(min ~ max)
1.76~2.84
1.76~3.24
1.76~4.52
1.85~5.80
1.88~5.96
1.88~6.23
1.88~6.24
1.88~6.91
1.88~6.23
1.88~6.35
1.88~6.91
1.88~6.40
1.88~6.92
1.86~7.04
1.86~7.04
1.95~7.06
1.86~7.04
1.95~7.06
1.95~7.07
1.95~7.04
1.95~7.06
2.04~7.30

Total input (kW)


Rating
0.46
0.62
0.97
1.54
0.95
1.18
1.55
1.28
1.45
1.55
1.28
1.55
1.26
1.24
1.24
1.24
1.24
1.24
1.24
1.24
1.23
1.22

(min ~ max)
0.35~0.74
0.35~0.80
0.35~1.51
0.35~2.10
0.35~1.91
0.35~2.14
0.35~2.14
0.35~2.07
0.35~2.14
0.35~2.25
0.35~2.07
0.35~2.25
0.35~2.08
0.35~2.16
0.35~2.16
0.37~2.16
0.35~2.16
0.37~2.16
0.37~2.16
0.37~2.16
0.37~2.16
0.39~2.19

Total current (A)


Rating
2.0
2.7
4.1
6.5
4.0
5.0
6.5
5.4
6.1
6.5
5.4
6.5
5.3
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.1

(min ~ max)
1.5~3.2
1.5~3.4
1.5~6.4
1.5~8.8
1.5~8.0
1.5~9.0
1.5~9.0
1.5~8.7
1.5~9.0
1.5~9.5
1.5~8.7
1.5~9.5
1.5~8.8
1.5~9.1
1.5~9.1
1.6~9.1
1.5~9.1
1.6~9.1
1.6~9.1
1.6~9.1
1.6~9.1
1.6~9.2

Power
factor (%)
Rating
96
97
98
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99

Heating [50Hz 240V]


Capacity of each indoor unit
Combination of
indoor unit
2.0
2.5
3.5
5.0
2.0+2.0
2.0+2.5
2.0+3.5
2.0+5.0
2.5+2.5
2.5+3.5
2.5+5.0
3.5+3.5
3.5+5.0
2.0+2.0+2.0
2.0+2.0+2.5
2.0+2.0+3.5
2.0+2.5+2.5
2.0+2.5+3.5
2.0+3.5+3.5
2.5+2.5+2.5
2.5+2.5+3.5
2.0+2.0+5.0

Each capacity (kW)


A room
2.72
3.40
4.20
5.80
3.05
2.78
2.38
1.94
3.25
2.79
2.27
3.40
2.80
2.26
2.09
1.80
1.94
1.70
1.52
2.26
2.00
1.51

Note:

B room

3.05
3.47
4.17
4.86
3.25
3.97
4.53
3.40
4.00
2.26
2.09
1.80
2.42
2.13
2.64
2.26
2.00
1.51

C room

2.26
2.60
3.18
2.42
2.97
2.64
2.26
2.80
3.78

Total capacity (kW)


Rating
2.72
3.40
4.20
5.80
6.10
6.25
6.55
6.80
6.50
6.70
6.80
6.80
6.80
6.78
6.78
6.78
6.78
6.80
6.80
6.78
6.80
6.80

(min ~ max)
1.21~3.75
1.21~4.00
1.21~4.82
1.30~6.79
1.28~7.00
1.28~7.00
1.34~7.04
1.36~7.95
1.28~7.00
1.34~7.19
1.42~7.95
1.40~7.22
1.42~7.98
1.34~8.02
1.34~8.02
1.45~8.05
1.34~8.02
1.57~8.05
1.56~8.08
1.45~8.02
1.57~8.05
1.64~8.30

Total input (kW)


Rating
0.72
0.99
1.39
1.74
1.70
1.75
1.86
1.52
1.86
1.93
1.52
1.97
1.52
1.57
1.57
1.56
1.57
1.56
1.56
1.57
1.56
1.42

(min ~ max)
0.30~1.20
0.30~1.26
0.30~1.68
0.30~2.51
0.31~2.28
0.31~2.28
0.31~2.28
0.31~2.22
0.31~2.31
0.31~2.36
0.31~2.22
0.31~2.35
0.31~2.21
0.32~2.14
0.32~2.14
0.32~2.14
0.32~2.14
0.32~2.14
0.32~2.14
0.32~2.14
0.32~2.14
0.32~2.04

Total current (A)


Rating
3.1
4.3
5.9
7.3
7.2
7.4
7.8
6.4
7.8
8.1
6.4
8.3
6.4
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.0

(min ~ max)
1.3~5.2
1.3~5.4
1.3~7.1
1.3~10.6
1.3~9.6
1.3~9.6
1.3~9.6
1.3~9.3
1.3~9.7
1.3~9.9
1.3~9.3
1.3~9.9
1.3~9.3
1.3~9.0
1.3~9.0
1.3~9.0
1.3~9.0
1.3~9.0
1.3~9.0
1.3~9.0
1.3~9.0
1.3~8.6

Power
factor (%)
Rating
96
97
98
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99

1. Cooling capacity is based on 27CDB/19CWB (Indoor temperature), 35CDB (Outdoor temperature).


Heating capacity is based on 20CDB (Indoor temperature), 7CDB/6CWB (Outdoor temperature).
2. The total ability of connected indoor units is up to 9.0kW.
3. It is impossible to connect the indoor unit for one room only.
3D055014
3D055016

SUPER MULTI NX E-Series Heat Pump

25

Specifications

3.3.2

EDAU12-722

3MXS68EVMA

Cooling [50Hz 230V]


Capacity of each indoor unit
Combination of
indoor unit
2.0
2.5
3.5
5.0
6.0
2.0+2.0
2.0+2.5
2.0+3.5
2.0+5.0
2.0+6.0
2.5+2.5
2.5+3.5
2.5+5.0
2.5+6.0
3.5+3.5
3.5+5.0
3.5+6.0
5.0+5.0
5.0+6.0
2.0+2.0+2.0
2.0+2.0+2.5
2.0+2.0+3.5
2.0+2.0+5.0
2.0+2.0+6.0
2.0+2.5+2.5
2.0+2.5+3.5
2.0+2.5+5.0
2.0+2.5+6.0
2.0+3.5+3.5
2.0+3.5+5.0
2.5+2.5+2.5
2.5+2.5+3.5
2.5+2.5+5.0
2.5+2.5+6.0
2.5+3.5+3.5
2.5+3.5+5.0
3.5+3.5+3.5

Each capacity (kW)


A room
2.00
2.50
3.50
5.00
6.00
2.00
2.00
2.00
1.94
1.70
2.50
2.50
2.27
2.00
3.40
2.80
2.51
3.40
3.09
2.00
2.00
1.81
1.51
1.36
1.94
1.70
1.43
1.30
1.52
1.30
2.26
2.00
1.70
1.55
1.78
1.55
2.26

Note:

B room

2.00
2.50
3.50
4.86
5.10
2.50
3.50
4.53
4.80
3.40
4.00
4.29
3.40
3.71
2.00
2.00
1.81
1.51
1.36
2.43
2.13
1.79
1.62
2.64
2.27
2.26
2.00
1.70
1.55
2.51
2.16
2.26

C room

2.00
2.50
3.18
3.78
4.08
2.43
2.97
3.58
3.88
2.64
3.23
2.26
2.80
3.40
3.70
2.51
3.09
2.26

Total capacity (kW)


Rating
2.00
2.50
3.50
5.00
6.00
4.00
4.50
5.50
6.80
6.80
5.00
6.00
6.80
6.80
6.80
6.80
6.80
6.80
6.80
6.00
6.50
6.80
6.80
6.80
6.80
6.80
6.80
6.80
6.80
6.80
6.80
6.80
6.80
6.80
6.80
6.80
6.80

(min ~ max)
1.63~2.57
1.70~3.39
1.71~4.73
1.87~5.88
1.89~6.35
1.82~5.02
1.83~5.31
1.92~6.20
1.99~7.10
2.12~7.58
1.83~5.97
1.90~6.43
2.10~7.25
2.15~7.60
1.98~6.97
2.15~7.63
2.25~7.90
2.36~8.11
2.42~8.29
1.92~6.45
1.93~6.85
2.04~7.21
2.23~7.90
2.36~8.15
2.04~7.10
2.15~7.58
2.23~7.93
2.36~8.37
2.15~7.88
2.36~8.37
2.04~7.45
2.15~7.79
2.35~8.27
2.42~8.53
2.25~8.11
2.42~8.53
2.37~8.44

Total input (kW)


Rating
0.49
0.65
1.02
1.65
2.23
1.10
1.34
1.86
2.44
2.39
1.71
2.43
2.44
2.39
2.77
2.44
2.37
2.19
2.14
1.76
2.07
2.26
2.10
2.05
2.28
2.23
2.10
2.04
2.23
2.05
2.23
2.23
2.05
2.03
2.23
2.05
2.21

(min ~ max)
0.40~0.67
0.44~0.91
0.45~1.43
0.47~2.14
0.45~2.44
0.43~1.59
0.44~1.75
0.45~2.38
0.46~2.51
0.48~2.76
0.46~2.19
0.46~2.63
0.47~2.64
0.47~2.84
0.45~2.85
0.47~2.87
0.47~3.11
0.49~2.95
0.49~3.06
0.45~1.95
0.45~2.18
0.47~2.47
0.48~2.69
0.50~2.82
0.47~2.38
0.47~2.68
0.48~2.69
0.50~3.01
0.48~2.99
0.49~3.12
0.47~2.58
0.47~2.86
0.50~2.96
0.49~3.18
0.47~3.20
0.49~3.25
0.47~3.33

Total current (A)


Rating
2.2
2.9
4.5
7.2
9.8
4.8
5.9
8.2
10.7
10.5
7.5
10.7
10.7
10.5
12.2
10.7
10.4
9.6
9.4
7.7
9.1
9.9
9.2
9.0
10.0
9.8
9.2
9.0
9.8
9.0
9.8
9.8
9.0
8.9
9.8
9.0
9.7

(min ~ max)
1.8~3.0
2.0~4.1
2.0~6.3
2.1~9.4
2.0~10.7
1.9~7.0
1.9~7.7
2.0~10.5
2.0~11.0
2.1~12.1
2.0~9.6
2.0~11.6
2.1~11.6
2.1~12.5
2.0~12.5
2.1~12.6
2.1~13.7
2.2~13.0
2.2~13.4
2.0~8.6
2.0~9.6
2.1~10.8
2.1~11.8
2.2~12.4
2.1~10.5
2.1~11.8
2.1~11.8
2.2~13.2
2.1~13.1
2.2~13.7
2.1~11.3
2.1~12.6
2.2~13.0
2.2~14.0
2.1~14.1
2.2~14.3
2.1~14.6

Power
factor (%)
Rating
96
96
98
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99

1. Cooling capacity is based on 27CDB/19CWB (Indoor temperature), 35CDB (Outdoor temperature).


Heating capacity is based on 20CDB (Indoor temperature), 7CDB/6CWB (Outdoor temperature).
2. The total ability of connected indoor units is up to 11.0kW.
3. It is impossible to connect the indoor unit for one room only.
3D055073

26

SUPER MULTI NX E-Series Heat Pump

EDAU12-722

Specifications

Heating [50Hz 230V]


Capacity of each indoor unit
Combination of
indoor unit
2.0
2.5
3.5
5.0
6.0
2.0+2.0
2.0+2.5
2.0+3.5
2.0+5.0
2.0+6.0
2.5+2.5
2.5+3.5
2.5+5.0
2.5+6.0
3.5+3.5
3.5+5.0
3.5+6.0
5.0+5.0
5.0+6.0
2.0+2.0+2.0
2.0+2.0+2.5
2.0+2.0+3.5
2.0+2.0+5.0
2.0+2.0+6.0
2.0+2.5+2.5
2.0+2.5+3.5
2.0+2.5+5.0
2.0+2.5+6.0
2.0+3.5+3.5
2.0+3.5+5.0
2.5+2.5+2.5
2.5+2.5+3.5
2.5+2.5+5.0
2.5+2.5+6.0
2.5+3.5+3.5
2.5+3.5+5.0
3.5+3.5+3.5

Each capacity (kW)


A room
2.72
3.40
4.30
7.20
7.90
3.25
3.04
2.71
2.46
2.15
3.60
3.29
2.87
2.53
4.30
3.54
3.17
4.30
3.91
2.63
2.54
2.29
1.91
1.72
2.46
2.15
1.81
1.64
1.92
1.64
2.86
2.53
2.15
1.95
2.26
1.95
2.86

Note:

B room

3.25
3.81
4.74
6.14
6.45
3.60
4.61
5.73
6.07
4.30
5.06
5.43
4.30
4.69
2.63
2.54
2.29
1.91
1.72
3.07
2.69
2.26
2.05
3.34
2.87
2.86
2.53
2.15
1.95
3.17
2.74
2.86

C room

2.63
3.17
4.02
4.78
5.16
3.07
3.76
4.53
4.91
3.34
4.09
2.86
3.54
4.30
4.70
3.17
3.91
2.86

Total capacity (kW)


Rating
2.72
3.40
4.30
7.20
7.90
6.50
6.85
7.45
8.60
8.60
7.20
7.90
8.60
8.60
8.60
8.60
8.60
8.60
8.60
7.89
8.25
8.60
8.60
8.60
8.60
8.60
8.60
8.60
8.60
8.60
8.60
8.60
8.60
8.60
8.60
8.60
8.60

(min ~ max)
1.22~3.88
1.23~4.11
1.29~4.47
1.61~8.02
1.93~8.51
1.61~7.65
1.61~7.82
1.75~8.35
2.15~10.12
2.43~10.32
1.61~8.14
1.90~8.62
2.26~10.23
2.53~10.40
2.13~8.97
2.50~10.41
2.73~10.56
2.83~10.61
3.04~10.64
1.89~10.03
2.02~10.12
2.27~10.20
2.67~10.47
2.81~10.60
2.15~10.12
2.36~10.20
2.70~10.61
2.93~10.64
2.68~10.41
3.02~10.64
2.26~10.23
2.50~10.41
2.83~10.61
3.04~10.64
2.73~10.56
3.04~10.64
3.01~10.62

Total input (kW)


Rating
0.79
1.09
1.41
2.42
2.51
1.83
2.01
2.28
2.42
2.31
2.19
2.55
2.42
2.31
2.87
2.41
2.28
2.24
2.15
2.01
2.12
2.30
2.13
2.08
2.30
2.29
2.08
2.06
2.27
2.08
2.29
2.29
2.08
2.04
2.25
2.08
2.25

(min ~ max)
0.37~1.23
0.37~1.33
0.38~1.56
0.40~2.71
0.43~2.71
0.40~2.20
0.40~2.29
0.41~2.57
0.49~2.89
0.54~2.92
0.40~2.50
0.43~2.80
0.51~2.93
0.57~2.93
0.48~3.03
0.57~3.01
0.59~2.92
0.65~2.80
0.64~2.74
0.44~2.64
0.47~2.68
0.50~2.80
0.61~2.62
0.60~2.61
0.48~2.73
0.52~2.80
0.61~2.65
0.63~2.57
0.59~2.84
0.67~2.72
0.50~2.80
0.54~2.88
0.65~2.68
0.66~2.58
0.58~2.88
0.68~2.67
0.67~2.94

Total current (A)


Rating
3.5
4.8
6.2
10.6
11.0
8.0
8.8
10.0
10.6
10.1
9.7
11.2
10.6
10.1
12.6
10.6
10.0
9.8
9.4
8.8
9.3
10.1
9.4
9.1
10.1
10.1
9.1
9.0
10.0
9.1
10.1
10.1
9.1
9.0
10.0
9.1
9.9

(min ~ max)
1.6~5.5
1.6~5.9
1.7~6.9
1.8~11.9
1.9~11.9
1.8~9.7
1.8~10.1
1.8~11.3
2.2~12.7
2.4~12.8
1.8~11.0
1.9~12.3
2.2~12.9
2.5~12.9
2.1~13.3
2.5~13.2
2.6~12.8
2.9~12.3
2.8~12.0
1.9~11.6
2.1~11.8
2.2~12.3
2.7~11.5
2.6~11.5
2.1~12.0
2.3~12.3
2.7~11.6
2.8~11.3
2.6~12.5
2.9~11.9
2.2~12.3
2.4~12.6
2.9~11.8
2.9~11.3
2.5~12.6
3.0~11.7
2.9~12.9

Power
factor (%)
Rating
98
98
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99

1. Cooling capacity is based on 27CDB/19CWB (Indoor temperature), 35CDB (Outdoor temperature).


Heating capacity is based on 20CDB (Indoor temperature), 7CDB/6CWB (Outdoor temperature).
2. The total ability of connected indoor units is up to 11.0kW.
3. It is impossible to connect the indoor unit for one room only.
3D055074

SUPER MULTI NX E-Series Heat Pump

27

Specifications

EDAU12-722

Cooling [50Hz 240V]


Capacity of each indoor unit
Combination of
indoor unit
2.0
2.5
3.5
5.0
6.0
2.0+2.0
2.0+2.5
2.0+3.5
2.0+5.0
2.0+6.0
2.5+2.5
2.5+3.5
2.5+5.0
2.5+6.0
3.5+3.5
3.5+5.0
3.5+6.0
5.0+5.0
5.0+6.0
2.0+2.0+2.0
2.0+2.0+2.5
2.0+2.0+3.5
2.0+2.0+5.0
2.0+2.0+6.0
2.0+2.5+2.5
2.0+2.5+3.5
2.0+2.5+5.0
2.0+2.5+6.0
2.0+3.5+3.5
2.0+3.5+5.0
2.5+2.5+2.5
2.5+2.5+3.5
2.5+2.5+5.0
2.5+2.5+6.0
2.5+3.5+3.5
2.5+3.5+5.0
3.5+3.5+3.5

Each capacity (kW)


A room
2.00
2.50
3.50
5.00
6.00
2.00
2.00
2.00
1.94
1.70
2.50
2.50
2.27
2.00
3.40
2.80
2.51
3.40
3.09
2.00
2.00
1.81
1.51
1.36
1.94
1.70
1.43
1.30
1.52
1.30
2.26
2.00
1.70
1.55
1.78
1.55
2.26

Note:

B room

2.00
2.50
3.50
4.86
5.10
2.50
3.50
4.53
4.80
3.40
4.00
4.29
3.40
3.71
2.00
2.00
1.81
1.51
1.36
2.43
2.13
1.79
1.62
2.64
2.27
2.26
2.00
1.70
1.55
2.51
2.16
2.26

C room

2.00
2.50
3.18
3.78
4.08
2.43
2.97
3.58
3.88
2.64
3.23
2.26
2.80
3.40
3.70
2.51
3.09
2.26

Total capacity (kW)


Rating
2.00
2.50
3.50
5.00
6.00
4.00
4.50
5.50
6.80
6.80
5.00
6.00
6.80
6.80
6.80
6.80
6.80
6.80
6.80
6.00
6.50
6.80
6.80
6.80
6.80
6.80
6.80
6.80
6.80
6.80
6.80
6.80
6.80
6.80
6.80
6.80
6.80

(min ~ max)
1.63~2.57
1.70~3.39
1.71~4.73
1.87~5.88
1.89~6.35
1.82~5.02
1.83~5.31
1.92~6.20
1.99~7.10
2.12~7.58
1.83~5.97
1.90~6.43
2.10~7.25
2.15~7.60
1.98~6.97
2.15~7.63
2.25~7.90
2.36~8.11
2.42~8.29
1.92~6.45
1.93~6.85
2.04~7.21
2.23~7.90
2.36~8.15
2.04~7.10
2.15~7.58
2.23~7.93
2.36~8.37
2.15~7.88
2.36~8.37
2.04~7.45
2.15~7.79
2.35~8.27
2.42~8.53
2.25~8.11
2.42~8.53
2.37~8.44

Total input (kW)


Rating
0.49
0.65
1.02
1.65
2.23
1.10
1.34
1.86
2.44
2.39
1.71
2.43
2.44
2.39
2.77
2.44
2.37
2.19
2.14
1.76
2.07
2.26
2.10
2.05
2.28
2.23
2.10
2.04
2.23
2.05
2.23
2.23
2.05
2.03
2.23
2.05
2.21

(min ~ max)
0.40~0.67
0.44~0.91
0.45~1.43
0.47~2.14
0.45~2.44
0.43~1.59
0.44~1.75
0.45~2.38
0.46~2.51
0.48~2.76
0.46~2.19
0.46~2.63
0.47~2.64
0.47~2.84
0.45~2.85
0.47~2.87
0.47~3.11
0.49~2.95
0.49~3.06
0.45~1.95
0.45~2.18
0.47~2.47
0.48~2.69
0.50~2.82
0.47~2.38
0.47~2.68
0.48~2.69
0.50~3.01
0.48~2.99
0.49~3.12
0.47~2.58
0.47~2.86
0.50~2.96
0.49~3.18
0.47~3.20
0.49~3.25
0.47~3.33

Total current (A)


Rating
2.1
2.8
4.3
6.9
9.4
4.6
5.6
7.8
10.3
10.1
7.2
10.2
10.3
10.1
11.7
10.3
10.0
9.2
9.0
7.4
8.7
9.5
8.8
8.6
9.6
9.4
8.8
8.6
9.4
8.6
9.4
9.4
8.6
8.5
9.4
8.6
9.3

(min ~ max)
1.7~2.9
1.9~3.9
1.9~6.1
2.0~9.0
1.9~10.3
1.8~6.7
1.9~7.4
1.9~10.0
1.9~10.6
2.0~11.6
1.9~9.2
1.9~11.1
2.0~11.1
2.0~12.0
1.9~12.0
2.0~12.1
2.0~13.1
2.1~12.4
2.1~12.9
1.9~8.2
1.9~9.2
2.0~10.4
2.0~11.3
2.1~11.9
2.0~10.0
2.0~11.3
2.0~11.3
2.1~12.7
2.0~12.6
2.1~13.1
2.0~10.9
2.0~12.0
2.1~12.5
2.1~13.4
2.0~13.5
2.1~13.7
2.0~14.0

Power
factor (%)
Rating
96
96
98
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99

1. Cooling capacity is based on 27CDB/19CWB (Indoor temperature), 35CDB (Outdoor temperature).


Heating capacity is based on 20CDB (Indoor temperature), 7CDB/6CWB (Outdoor temperature).
2. The total ability of connected indoor units is up to 11.0kW.
3. It is impossible to connect the indoor unit for one room only.
3D055075

28

SUPER MULTI NX E-Series Heat Pump

EDAU12-722

Specifications

Heating [50Hz 240V]


Capacity of each indoor unit
Combination of
indoor unit
2.0
2.5
3.5
5.0
6.0
2.0+2.0
2.0+2.5
2.0+3.5
2.0+5.0
2.0+6.0
2.5+2.5
2.5+3.5
2.5+5.0
2.5+6.0
3.5+3.5
3.5+5.0
3.5+6.0
5.0+5.0
5.0+6.0
2.0+2.0+2.0
2.0+2.0+2.5
2.0+2.0+3.5
2.0+2.0+5.0
2.0+2.0+6.0
2.0+2.5+2.5
2.0+2.5+3.5
2.0+2.5+5.0
2.0+2.5+6.0
2.0+3.5+3.5
2.0+3.5+5.0
2.5+2.5+2.5
2.5+2.5+3.5
2.5+2.5+5.0
2.5+2.5+6.0
2.5+3.5+3.5
2.5+3.5+5.0
3.5+3.5+3.5

Each capacity (kW)


A room
2.72
3.40
4.30
7.20
7.90
3.25
3.04
2.71
2.46
2.15
3.60
3.29
2.87
2.53
4.30
3.54
3.17
4.30
3.91
2.63
2.54
2.29
1.91
1.72
2.46
2.15
1.81
1.64
1.92
1.64
2.86
2.53
2.15
1.95
2.26
1.95
2.86

Note:

B room

3.25
3.81
4.74
6.14
6.45
3.60
4.61
5.73
6.07
4.30
5.06
5.43
4.30
4.69
2.63
2.54
2.29
1.91
1.72
3.07
2.69
2.26
2.05
3.34
2.87
2.86
2.53
2.15
1.95
3.17
2.74
2.86

C room

2.63
3.17
4.02
4.78
5.16
3.07
3.76
4.53
4.91
3.34
4.09
2.86
3.54
4.30
4.70
3.17
3.91
2.86

Total capacity (kW)


Rating
2.72
3.40
4.30
7.20
7.90
6.50
6.85
7.45
8.60
8.60
7.20
7.90
8.60
8.60
8.60
8.60
8.60
8.60
8.60
7.89
8.25
8.60
8.60
8.60
8.60
8.60
8.60
8.60
8.60
8.60
8.60
8.60
8.60
8.60
8.60
8.60
8.60

(min ~ max)
1.22~3.88
1.23~4.11
1.29~4.47
1.61~8.02
1.93~8.51
1.61~7.65
1.61~7.82
1.75~8.35
2.15~10.12
2.43~10.32
1.61~8.14
1.90~8.62
2.26~10.23
2.53~10.40
2.13~8.97
2.50~10.41
2.73~10.56
2.83~10.61
3.04~10.64
1.89~10.03
2.02~10.12
2.27~10.20
2.67~10.47
2.81~10.60
2.15~10.12
2.36~10.20
2.70~10.61
2.93~10.64
2.68~10.41
3.02~10.64
2.26~10.23
2.50~10.41
2.83~10.61
3.04~10.64
2.73~10.56
3.04~10.64
3.01~10.62

Total input (kW)


Rating
0.79
1.09
1.41
2.42
2.51
1.83
2.01
2.28
2.42
2.31
2.20
2.56
2.42
2.31
2.87
2.41
2.28
2.24
2.15
2.01
2.12
2.30
2.13
2.08
2.30
2.29
2.08
2.06
2.27
2.08
2.30
2.29
2.08
2.04
2.27
2.08
2.25

(min ~ max)
0.37~1.23
0.37~1.33
0.38~1.56
0.40~2.71
0.43~2.71
0.40~2.20
0.40~2.29
0.41~2.57
0.49~2.89
0.54~2.92
0.40~2.50
0.43~2.80
0.51~2.93
0.57~2.93
0.48~3.03
0.57~3.01
0.59~2.92
0.65~2.80
0.64~2.74
0.44~2.64
0.47~2.68
0.50~2.80
0.61~2.62
0.60~2.61
0.48~2.73
0.52~2.80
0.61~2.65
0.63~2.57
0.59~2.84
0.67~2.72
0.50~2.80
0.54~2.88
0.65~2.68
0.66~2.58
0.58~2.88
0.68~2.67
0.67~2.94

Total current (A)


Rating
3.4
4.6
5.9
10.2
10.6
7.7
8.5
9.6
10.2
9.7
9.3
10.8
10.2
9.7
12.1
10.1
9.6
9.4
9.0
8.5
8.9
9.7
9.0
8.8
9.7
9.6
8.8
8.7
9.6
8.8
9.7
9.6
8.8
8.6
9.6
8.8
9.5

(min ~ max)
1.6~5.2
1.6~5.7
1.6~6.6
1.7~11.4
1.8~11.4
1.7~9.3
1.7~9.6
1.7~10.8
2.1~12.2
2.3~12.3
1.7~10.5
1.8~11.8
2.1~12.3
2.4~12.3
2.0~12.8
2.4~12.7
2.5~12.3
2.7~11.8
2.7~11.5
1.9~11.1
2.0~11.3
2.1~11.8
2.6~11.0
2.5~11.0
2.0~11.5
2.2~11.8
2.6~11.2
2.7~10.8
2.5~12.0
2.8~11.4
2.1~11.8
2.3~12.1
2.7~11.3
2.8~10.9
2.4~12.1
2.9~11.2
2.8~12.4

Power
factor (%)
Rating
98
98
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99

1. Cooling capacity is based on 27CDB/19CWB (Indoor temperature), 35CDB (Outdoor temperature).


Heating capacity is based on 20CDB (Indoor temperature), 7CDB/6CWB (Outdoor temperature).
2. The total ability of connected indoor units is up to 11.0kW.
3. It is impossible to connect the indoor unit for one room only.
3D055076

SUPER MULTI NX E-Series Heat Pump

29

Specifications

3.3.3

EDAU12-722

4MXS80EVMA

Cooling [50Hz / 60Hz 220V]


Capacity of each indoor unit
Combination of
indoor unit
2.0
2.5
3.5
5.0
6.0
7.1
2.0+2.0
2.0+2.5
2.0+3.5
2.0+5.0
2.0+6.0
2.0+7.1
2.5+2.5
2.5+3.5
2.5+5.0
2.5+6.0
2.5+7.1
3.5+3.5
3.5+5.0
3.5+6.0
3.5+7.1
5.0+5.0
5.0+6.0
5.0+7.1
6.0+6.0
6.0+7.1
7.1+7.1
2.0+2.0+2.0
2.0+2.0+2.5
2.0+2.0+3.5
2.0+2.0+5.0
2.0+2.0+6.0
2.0+2.0+7.1
2.0+2.5+2.5
2.0+2.5+3.5
2.0+2.5+5.0
2.0+2.5+6.0
2.0+2.5+7.1
2.0+3.5+3.5
2.0+3.5+5.0
2.0+3.5+6.0
2.0+3.5+7.1
2.0+5.0+5.0
2.0+5.0+6.0
2.0+5.0+7.1
2.0+6.0+6.0
2.5+2.5+2.5
2.5+2.5+3.5
2.5+2.5+5.0
2.5+2.5+6.0
2.5+2.5+7.1
2.5+3.5+3.5
2.5+3.5+5.0
2.5+3.5+6.0
2.5+3.5+7.1
2.5+5.0+5.0
2.5+5.0+6.0
2.5+6.0+6.0
3.5+3.5+3.5
3.5+3.5+5.0
3.5+3.5+6.0
3.5+3.5+7.1
3.5+5.0+5.0
3.5+5.0+6.0
2.0+2.0+2.0+2.0

30

Each capacity (kW)

Total capacity (kW)

A room B room C room D room Rating


2.00

2.00
2.50

2.50
3.50

3.50
5.00

5.00
6.00

6.00
7.10

7.10
2.00
2.00

4.00
2.00
2.50

4.50
2.00
3.50

5.50
2.00
5.00

7.00
1.83
5.48

7.31
1.66
5.90

7.56
2.50
2.50

5.00
2.50
3.50

6.00
2.40
4.79

7.19
2.18
5.24

7.42
2.00
5.68

7.68
3.50
3.50

7.00
3.06
4.36

7.42
2.82
4.83

7.65
2.61
5.30

7.91
3.88
3.88

7.76
3.64
4.36

8.00
3.31
4.69

8.00
4.00
4.00

8.00
3.66
4.34

8.00
4.00
4.00

8.00
2.00
2.00
2.00

6.00
2.00
2.00
2.50

6.50
1.92
1.92
3.35

7.19
1.68
1.68
4.18

7.54
1.55
1.55
4.67

7.77
1.44
1.44
5.12

8.00
2.00
2.50
2.50

7.00
1.83
2.28
3.20

7.31
1.61
2.01
4.03

7.65
1.50
1.88
4.50

7.88
1.38
1.72
4.90

8.00
1.68
2.93
2.93

7.54
1.50
2.63
3.75

7.88
1.39
2.43
4.18

8.00
1.27
2.22
4.51

8.00
1.34
3.33
3.33

8.00
1.23
3.08
3.69

8.00
1.13
2.84
4.03

8.00
1.14
3.43
3.43

8.00
2.40
2.40
2.40

7.20
2.18
2.18
3.06

7.42
1.94
1.94
3.89

7.77
1.82
1.82
4.36

8.00
1.65
1.65
4.70

8.00
2.01
2.82
2.82

7.65
1.81
2.55
3.64

8.00
1.67
2.33
4.00

8.00
1.52
2.14
4.34

8.00
1.60
3.20
3.20

8.00
1.48
2.96
3.56

8.00
1.38
3.31
3.31

8.00
2.63
2.63
2.63

7.89
2.33
2.33
3.34

8.00
2.15
2.15
3.70

8.00
1.99
1.99
4.02

8.00
2.08
2.96
2.96

8.00
1.93
2.76
3.31

8.00
1.83
1.83
1.83
1.83
7.32

(min ~ max)
1.80~2.99
1.87~3.52
1.91~4.85
2.07~5.65
2.17~6.60
2.28~7.26
1.97~5.30
2.02~5.73
2.12~6.38
2.27~7.30
2.41~7.90
2.56~8.22
2.07~6.17
2.17~6.60
2.34~7.59
2.48~8.03
2.63~8.22
2.27~7.27
2.48~8.01
2.61~8.54
2.77~8.23
2.68~8.76
2.82~8.79
2.97~8.99
2.96~9.00
3.11~9.02
3.26~9.04
2.17~6.63
2.22~6.95
2.34~7.61
2.55~8.40
2.68~8.82
2.83~9.03
2.27~7.30
2.41~7.90
2.61~8.62
2.75~8.84
2.90~9.03
2.55~8.23
2.75~8.81
2.89~9.02
3.04~9.07
2.96~9.39
3.09~9.54
3.25~9.60
3.23~9.60
2.34~7.61
2.48~8.05
2.68~8.80
2.82~8.84
2.97~9.03
2.61~8.34
2.82~8.81
2.96~9.02
3.11~9.07
3.03~9.47
3.16~9.58
3.30~9.60
2.75~8.58
2.96~8.99
3.09~9.07
3.25~9.05
3.16~9.58
3.30~9.60
2.41~7.90

Total input (kW)


Rating
0.60
0.78
1.19
1.67
2.01
2.71
1.19
1.36
1.81
2.36
2.53
2.69
1.44
2.01
2.47
2.59
2.73
2.65
2.65
2.70
2.97
2.58
2.71
2.71
2.65
2.59
2.53
1.78
2.03
2.48
2.40
2.53
2.65
2.36
2.54
2.46
2.59
2.65
2.72
2.58
2.59
2.53
2.38
2.32
2.26
2.38
2.48
2.60
2.52
2.65
2.59
2.78
2.71
2.65
2.59
2.38
2.32
2.26
2.90
2.71
2.65
2.59
2.38
2.32
2.11

(min ~ max)
0.46~1.07
0.49~1.35
0.49~1.57
0.47~1.81
0.47~2.43
0.50~2.83
0.47~1.67
0.47~1.81
0.47~2.11
0.51~2.53
0.51~2.96
0.54~3.16
0.43~2.11
0.47~2.37
0.51~2.77
0.54~3.03
0.58~3.16
0.50~2.83
0.54~3.03
0.58~3.56
0.61~3.16
0.58~3.24
0.61~3.25
0.65~3.39
0.61~3.39
0.65~3.39
0.68~3.40
0.51~2.09
0.51~2.31
0.51~2.72
0.55~2.97
0.58~3.25
0.61~3.40
0.51~2.54
0.51~2.97
0.55~3.11
0.58~3.25
0.61~3.40
0.54~3.16
0.58~3.25
0.61~3.39
0.65~3.40
0.62~3.33
0.65~3.48
0.65~3.49
0.65~3.49
0.51~2.72
0.54~3.03
0.58~3.24
0.61~3.25
0.61~3.40
0.58~3.09
0.61~3.25
0.61~3.39
0.65~3.40
0.62~3.40
0.65~3.48
0.68~3.49
0.61~3.16
0.61~3.39
0.65~3.39
0.68~3.40
0.65~3.48
0.68~3.49
0.52~2.46

Total current (A)


Rating
2.8
3.6
5.5
7.7
9.3
12.6
5.5
6.3
8.4
10.9
11.7
12.5
6.7
9.3
11.5
12.0
12.7
12.3
12.3
12.5
13.8
12.0
12.6
12.6
12.3
12.0
11.7
8.3
9.4
11.5
11.1
11.7
12.3
10.9
11.8
11.4
12.0
12.3
12.6
12.0
12.0
11.7
11.0
10.8
10.5
11.0
11.5
12.1
11.7
12.3
12.0
12.9
12.6
12.3
12.0
11.0
10.8
10.5
13.5
12.6
12.3
12.0
11.0
10.8
9.8

(min ~ max)
2.1~5.0
2.3~6.3
2.3~7.3
2.2~8.4
2.2~11.3
2.3~13.1
2.2~7.7
2.2~8.4
2.2~9.8
2.4~11.7
2.4~13.7
2.5~14.7
2.0~9.8
2.2~11.0
2.4~12.8
2.5~14.1
2.7~14.7
2.3~13.1
2.5~14.1
2.7~16.5
2.8~14.7
2.7~15.0
2.8~15.1
3.0~15.7
2.8~15.7
3.0~15.7
3.2~15.8
2.4~9.7
2.4~10.7
2.4~12.6
2.6~13.8
2.7~15.1
2.8~15.8
2.4~11.8
2.4~13.8
2.6~14.4
2.7~15.1
2.8~15.8
2.5~14.7
2.7~15.1
2.8~15.7
3.0~15.8
2.9~15.4
3.0~16.1
3.0~16.2
3.0~16.2
2.4~12.6
2.5~14.1
2.7~15.0
2.8~15.1
2.8~15.8
2.7~14.3
2.8~15.1
2.8~15.7
3.0~15.8
2.9~15.8
3.0~16.1
3.2~16.2
2.8~14.7
2.8~15.7
3.0~15.7
3.2~15.8
3.0~16.1
3.2~16.2
2.4~11.4

Power
factor (%)
Rating
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98

SUPER MULTI NX E-Series Heat Pump

EDAU12-722

Specifications

Capacity of each indoor unit


Combination of
indoor unit
2.0+2.0+2.0+2.5
2.0+2.0+2.0+3.5
2.0+2.0+2.0+5.0
2.0+2.0+2.0+6.0
2.0+2.0+2.0+7.1
2.0+2.0+2.5+2.5
2.0+2.0+2.5+3.5
2.0+2.0+2.5+5.0
2.0+2.0+2.5+6.0
2.0+2.0+2.5+7.1
2.0+2.0+3.5+3.5
2.0+2.0+3.5+5.0
2.0+2.0+3.5+6.0
2.0+2.0+5.0+5.0
2.0+2.5+2.5+2.5
2.0+2.5+2.5+3.5
2.0+2.5+2.5+5.0
2.0+2.5+2.5+6.0
2.0+2.5+2.5+7.1
2.0+2.5+3.5+3.5
2.0+2.5+3.5+5.0
2.0+2.5+3.5+6.0
2.0+2.5+5.0+5.0
2.0+3.5+3.5+3.5
2.0+3.5+3.5+5.0
2.5+2.5+2.5+2.5
2.5+2.5+2.5+3.5
2.5+2.5+2.5+5.0
2.5+2.5+2.5+6.0
2.5+2.5+3.5+3.5
2.5+2.5+3.5+5.0
2.5+2.5+3.5+6.0
2.5+3.5+3.5+3.5
2.5+3.5+3.5+5.0
3.5+3.5+3.5+3.5

Each capacity (kW)

Total capacity (kW)

A room B room C room D room Rating


1.75
1.75
1.75
2.17
7.42
1.61
1.61
1.61
2.82
7.65
1.45
1.45
1.45
3.65
8.00
1.33
1.33
1.33
4.01
8.00
1.22
1.22
1.22
4.34
8.00
1.68
1.68
2.09
2.09
7.54
1.55
1.55
1.94
2.73
7.77
1.39
1.39
1.74
3.48
8.00
1.28
1.28
1.60
3.84
8.00
1.18
1.18
1.47
4.17
8.00
1.45
1.45
2.55
2.55
8.00
1.28
1.28
2.24
3.20
8.00
1.19
1.19
2.07
3.55
8.00
1.14
1.14
2.86
2.86
8.00
1.62
2.01
2.01
2.01
7.65
1.50
1.88
1.88
2.62
7.88
1.33
1.67
1.67
3.33
8.00
1.23
1.54
1.54
3.69
8.00
1.13
1.42
1.42
4.03
8.00
1.40
1.74
2.43
2.43
8.00
1.23
1.54
2.15
3.08
8.00
1.14
1.43
2.00
3.43
8.00
1.10
1.38
2.76
2.76
8.00
1.28
2.24
2.24
2.24
8.00
1.14
2.00
2.00
2.86
8.00
1.94
1.94
1.94
1.94
7.76
1.82
1.82
1.82
2.54
8.00
1.60
1.60
1.60
3.20
8.00
1.48
1.48
1.48
3.56
8.00
1.67
1.67
2.33
2.33
8.00
1.48
1.48
2.07
2.97
8.00
1.38
1.38
1.93
3.31
8.00
1.55
2.15
2.15
2.15
8.00
1.38
1.93
1.93
2.76
8.00
2.00
2.00
2.00
2.00
8.00

Note:

(min ~ max)
2.48~8.16
2.61~8.62
2.82~9.15
2.96~9.39
3.11~9.55
2.55~8.40
2.68~8.82
2.89~9.28
3.03~9.47
3.18~9.59
2.82~8.86
3.03~9.47
3.16~9.58
3.23~9.60
2.61~8.62
2.75~8.86
2.96~9.39
3.09~9.54
3.25~9.60
2.89~9.09
3.09~9.54
3.23~9.60
3.30~9.60
3.03~9.23
3.23~9.60
2.68~8.82
2.82~8.92
3.03~9.47
3.16~9.58
2.96~9.04
3.16~9.58
3.30~9.60
3.09~9.34
3.30~9.60
3.23~9.05

Total input (kW)


Rating
2.17
2.29
2.38
2.32
2.26
2.23
2.53
2.38
2.32
2.26
2.65
2.38
2.32
2.15
2.29
2.59
2.38
2.35
2.32
2.65
2.38
2.32
2.11
2.65
2.38
2.53
2.65
2.38
2.32
2.65
2.38
2.32
2.65
2.38
2.65

(min ~ max)
0.55~2.59
0.55~2.91
0.59~3.12
0.62~3.34
0.65~3.42
0.55~2.78
0.58~3.25
0.59~3.26
0.62~3.34
0.65~3.50
0.61~3.25
0.62~3.41
0.65~3.49
0.65~3.11
0.55~2.91
0.58~3.25
0.62~3.34
0.65~3.42
0.65~3.50
0.61~3.40
0.65~3.49
0.65~3.49
0.65~3.11
0.65~3.40
0.65~3.49
0.58~3.25
0.61~3.25
0.62~3.41
0.65~3.49
0.61~3.40
0.65~3.49
0.68~3.49
0.65~3.40
0.68~3.49
0.68~3.40

Total current (A)


Rating
10.1
10.6
11.0
10.8
10.5
10.3
11.7
11.0
10.8
10.5
12.3
11.0
10.8
10.0
10.6
12.0
11.0
10.9
10.8
12.3
11.0
10.8
9.8
12.3
11.0
11.7
12.3
11.0
10.8
12.3
11.0
10.8
12.3
11.0
12.3

(min ~ max)
2.6~12.0
2.6~13.5
2.7~14.5
2.9~15.5
3.0~15.9
2.6~12.9
2.7~15.1
2.7~15.1
2.9~15.5
3.0~16.2
2.8~15.1
2.9~15.8
3.0~16.2
3.0~14.4
2.6~13.5
2.7~15.1
2.9~15.5
3.0~15.9
3.0~16.2
2.8~15.8
3.0~16.2
3.0~16.2
3.0~14.4
3.0~15.8
3.0~16.2
2.7~15.1
2.8~15.1
2.9~15.8
3.0~16.2
2.8~15.8
3.0~16.2
3.2~16.2
3.0~15.8
3.2~16.2
3.2~15.8

Power
factor (%)
Rating
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98

1. Cooling capacity is based on 27CDB/19CWB (Indoor temperature), 35CDB (Outdoor temperature).


Heating capacity is based on 20CDB (Indoor temperature), 7CDB/6CWB (Outdoor temperature).
2. The total ability of connected indoor units is up to 14.5kW.
3. It is impossible to connect the indoor unit for one room only.
3D052664#2
3D052664#3
3D052664#4

SUPER MULTI NX E-Series Heat Pump

31

Specifications

EDAU12-722

Heating [50Hz / 60Hz 220V]


Capacity of each indoor unit
Combination of
indoor unit
2.0
2.5
3.5
5.0
6.0
7.1
2.0+2.0
2.0+2.5
2.0+3.5
2.0+5.0
2.0+6.0
2.0+7.1
2.5+2.5
2.5+3.5
2.5+5.0
2.5+6.0
2.5+7.1
3.5+3.5
3.5+5.0
3.5+6.0
3.5+7.1
5.0+5.0
5.0+6.0
5.0+7.1
6.0+6.0
6.0+7.1
7.1+7.1
2.0+2.0+2.0
2.0+2.0+2.5
2.0+2.0+3.5
2.0+2.0+5.0
2.0+2.0+6.0
2.0+2.0+7.1
2.0+2.5+2.5
2.0+2.5+3.5
2.0+2.5+5.0
2.0+2.5+6.0
2.0+2.5+7.1
2.0+3.5+3.5
2.0+3.5+5.0
2.0+3.5+6.0
2.0+3.5+7.1
2.0+5.0+5.0
2.0+5.0+6.0
2.0+5.0+7.1
2.0+6.0+6.0
2.5+2.5+2.5
2.5+2.5+3.5
2.5+2.5+5.0
2.5+2.5+6.0
2.5+2.5+7.1
2.5+3.5+3.5
2.5+3.5+5.0
2.5+3.5+6.0
2.5+3.5+7.1
2.5+5.0+5.0
2.5+5.0+6.0
2.5+6.0+6.0
3.5+3.5+3.5
3.5+3.5+5.0
3.5+3.5+6.0
3.5+3.5+7.1
3.5+5.0+5.0
3.5+5.0+6.0
2.0+2.0+2.0+2.0
2.0+2.0+2.0+2.5
2.0+2.0+2.0+3.5

32

Each capacity (kW)

Total capacity (kW)

A room B room C room D room Rating


2.44

2.44
3.05

3.05
4.27

4.27
6.09

6.09
7.31

7.31
8.65

8.65
2.44
2.44

4.88
2.44
3.05

5.49
2.44
4.26

6.70
2.44
6.09

8.53
2.32
6.95

9.27
2.11
7.49

9.60
3.04
3.04

6.08
3.05
4.26

7.31
2.98
5.95

8.93
2.82
6.78

9.60
2.50
7.10

9.60
4.26
4.26

8.52
3.95
5.65

9.60
3.54
6.06

9.60
3.17
6.43

9.60
4.80
4.80

9.60
4.36
5.24

9.60
3.97
5.63

9.60
4.80
4.80

9.60
4.40
5.20

9.60
4.80
4.80

9.60
2.43
2.43
2.43

7.29
2.44
2.44
3.04

7.92
2.38
2.38
4.17

8.93
2.13
2.13
5.34

9.60
1.92
1.92
5.76

9.60
1.73
1.73
6.14

9.60
2.43
3.05
3.05

8.53
2.31
2.90
4.06

9.27
2.02
2.53
5.05

9.60
1.82
2.29
5.49

9.60
1.65
2.07
5.88

9.60
2.14
3.73
3.73

9.60
1.83
3.20
4.57

9.60
1.67
2.92
5.01

9.60
1.52
2.67
5.41

9.60
1.60
4.00
4.00

9.60
1.48
3.69
4.43

9.60
1.37
3.40
4.83

9.60
1.38
4.11
4.11

9.60
2.97
2.97
2.97

8.91
2.82
2.82
3.96

9.60
2.40
2.40
4.80

9.60
2.18
2.18
5.24

9.60
1.98
1.98
5.64

9.60
2.52
3.54
3.54

9.60
2.19
3.05
4.36

9.60
2.00
2.80
4.80

9.60
1.84
2.56
5.20

9.60
1.92
3.84
3.84

9.60
1.77
3.56
4.27

9.60
1.66
3.97
3.97

9.60
3.20
3.20
3.20

9.60
2.80
2.80
4.00

9.60
2.58
2.58
4.44

9.60
2.38
2.38
4.84

9.60
2.48
3.56
3.56

9.60
2.32
3.31
3.97

9.60
2.32
2.32
2.32
2.32
9.28
2.26
2.26
2.26
2.82
9.60
2.02
2.02
2.02
3.54
9.60

(min ~ max)
1.31~4.10
1.36~4.55
1.48~4.94
1.90~6.92
2.19~7.92
2.50~8.70
1.62~6.55
1.76~6.85
2.05~7.35
2.47~8.53
2.74~9.35
3.04~10.02
1.90~6.92
2.19~8.24
2.61~9.14
2.88~9.77
3.17~10.02
2.47~8.87
2.88~9.74
3.15~10.00
3.45~10.03
3.28~10.27
3.55~10.31
3.85~10.34
3.82~10.35
4.12~10.38
4.42~10.41
2.19~8.05
2.33~8.64
2.61~9.37
3.01~10.32
3.28~10.35
3.58~10.39
2.47~8.64
2.74~9.37
3.15~10.32
3.42~10.35
3.72~10.39
3.01~10.01
3.42~10.32
3.69~10.36
3.99~10.39
3.82~10.64
4.09~10.67
4.39~10.71
4.36~10.71
2.61~9.55
2.88~9.78
3.28~10.32
3.55~10.35
3.85~10.39
3.15~10.01
3.55~10.32
3.82~10.36
4.12~10.39
3.96~10.64
4.23~10.67
4.50~10.71
3.42~10.02
3.82~10.33
4.09~10.37
4.39~10.40
4.23~10.64
4.50~10.68
2.74~9.45
2.88~9.60
3.15~10.37

Total input (kW)


Rating
0.71
0.93
1.51
1.83
2.32
2.94
1.24
1.43
1.97
2.40
2.59
2.63
1.79
2.26
2.55
2.81
2.66
2.87
2.81
2.64
2.58
2.44
2.43
2.42
2.46
2.45
2.39
1.87
2.08
2.43
2.42
2.41
2.40
2.29
2.56
2.42
2.41
2.40
2.58
2.42
2.41
2.40
2.26
2.25
2.24
2.23
2.48
2.69
2.42
2.41
2.40
2.58
2.42
2.41
2.40
2.26
2.25
2.23
2.58
2.42
2.40
2.39
2.26
2.25
2.41
2.51
2.41

(min ~ max)
0.33~1.29
0.35~1.39
0.36~1.79
0.44~2.23
0.58~2.63
0.62~2.97
0.36~1.85
0.40~1.93
0.46~2.26
0.56~2.40
0.60~2.64
0.64~2.84
0.44~2.17
0.58~2.67
0.58~2.66
0.62~2.94
0.67~2.88
0.63~3.11
0.63~2.87
0.65~2.85
0.72~2.78
0.63~2.76
0.67~2.74
0.71~2.73
0.71~2.78
0.76~2.77
0.83~2.70
0.51~2.17
0.53~2.36
0.58~2.64
0.58~2.74
0.61~2.72
0.66~2.71
0.56~2.34
0.60~2.61
0.60~2.74
0.64~2.72
0.68~2.71
0.62~2.79
0.64~2.74
0.68~2.72
0.73~2.71
0.64~2.67
0.70~2.66
0.74~2.64
0.74~2.64
0.58~2.74
0.62~2.79
0.62~2.74
0.66~2.72
0.70~2.71
0.64~2.79
0.67~2.74
0.71~2.72
0.75~2.71
0.68~2.67
0.73~2.66
0.77~2.64
0.69~2.79
0.71~2.73
0.76~2.72
0.80~2.71
0.73~2.67
0.78~2.65
0.51~2.51
0.55~2.51
0.59~2.72

Total current (A)


Rating
3.3
4.3
7.0
8.5
10.8
13.6
5.8
6.6
9.1
11.1
12.0
12.2
8.3
10.5
11.8
13.0
12.3
13.3
13.0
12.2
12.0
11.3
11.3
11.2
11.4
11.4
11.1
8.7
9.6
11.3
11.2
11.2
11.1
10.6
11.9
11.2
11.2
11.1
12.0
11.2
11.2
11.1
10.5
10.4
10.4
10.3
11.5
12.5
11.2
11.2
11.1
12.0
11.2
11.2
11.1
10.5
10.4
10.3
12.0
11.2
11.1
11.1
10.5
10.4
11.2
11.6
11.2

(min ~ max)
1.5~6.0
1.6~6.4
1.7~8.3
2.0~10.3
2.7~12.2
2.9~13.8
1.7~8.6
1.9~9.0
2.1~10.5
2.6~11.1
2.8~12.2
3.0~13.2
2.0~10.1
2.7~12.4
2.7~12.3
2.9~13.6
3.1~13.4
2.9~14.4
2.9~13.3
3.0~13.2
3.3~12.9
2.9~12.8
3.1~12.7
3.3~12.7
3.3~12.9
3.5~12.8
3.8~12.5
2.4~10.1
2.5~10.9
2.7~12.2
2.7~12.7
2.8~12.6
3.1~12.6
2.6~10.9
2.8~12.1
2.8~12.7
3.0~12.6
3.2~12.6
2.9~12.9
3.0~12.7
3.2~12.6
3.4~12.6
3.0~12.4
3.2~12.3
3.4~12.2
3.4~12.2
2.7~12.7
2.9~12.9
2.9~12.7
3.1~12.6
3.2~12.6
3.0~12.9
3.1~12.7
3.3~12.6
3.5~12.6
3.2~12.4
3.4~12.3
3.6~12.2
3.2~12.9
3.3~12.7
3.5~12.6
3.7~12.6
3.4~12.4
3.6~12.3
2.4~11.6
2.6~11.6
2.7~12.6

Power
factor (%)
Rating
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98

SUPER MULTI NX E-Series Heat Pump

EDAU12-722

Specifications

Capacity of each indoor unit


Combination of
indoor unit
2.0+2.0+2.0+5.0
2.0+2.0+2.0+6.0
2.0+2.0+2.0+7.1
2.0+2.0+2.5+2.5
2.0+2.0+2.5+3.5
2.0+2.0+2.5+5.0
2.0+2.0+2.5+6.0
2.0+2.0+2.5+7.1
2.0+2.0+3.5+3.5
2.0+2.0+3.5+5.0
2.0+2.0+3.5+6.0
2.0+2.0+5.0+5.0
2.0+2.5+2.5+2.5
2.0+2.5+2.5+3.5
2.0+2.5+2.5+5.0
2.0+2.5+2.5+6.0
2.0+2.5+2.5+7.1
2.0+2.5+3.5+3.5
2.0+2.5+3.5+5.0
2.0+2.5+3.5+6.0
2.0+2.5+5.0+5.0
2.0+3.5+3.5+3.5
2.0+3.5+3.5+5.0
2.5+2.5+2.5+2.5
2.5+2.5+2.5+3.5
2.5+2.5+2.5+5.0
2.5+2.5+2.5+6.0
2.5+2.5+3.5+3.5
2.5+2.5+3.5+5.0
2.5+2.5+3.5+6.0
2.5+3.5+3.5+3.5
2.5+3.5+3.5+5.0
3.5+3.5+3.5+3.5

Each capacity (kW)

Total capacity (kW)

A room B room C room D room Rating


1.75
1.75
1.75
4.35
9.60
1.60
1.60
1.60
4.80
9.60
1.47
1.47
1.47
5.19
9.60
2.13
2.13
2.67
2.67
9.60
1.92
1.92
2.40
3.36
9.60
1.67
1.67
2.09
4.17
9.60
1.54
1.54
1.92
4.60
9.60
1.41
1.41
1.76
5.02
9.60
1.75
1.75
3.05
3.05
9.60
1.54
1.54
2.69
3.83
9.60
1.42
1.42
2.49
4.27
9.60
1.37
1.37
3.43
3.43
9.60
2.01
2.53
2.53
2.53
9.60
1.82
2.29
2.29
3.20
9.60
1.60
2.00
2.00
4.00
9.60
1.47
1.85
1.85
4.43
9.60
1.37
1.70
1.70
4.83
9.60
1.67
2.09
2.92
2.92
9.60
1.48
1.85
2.58
3.69
9.60
1.38
1.71
2.40
4.11
9.60
1.32
1.66
3.31
3.31
9.60
1.53
2.69
2.69
2.69
9.60
1.37
2.40
2.40
3.43
9.60
2.40
2.40
2.40
2.40
9.60
2.18
2.18
2.18
3.06
9.60
1.92
1.92
1.92
3.84
9.60
1.78
1.78
1.78
4.26
9.60
2.00
2.00
2.80
2.80
9.60
1.78
1.78
2.49
3.55
9.60
1.66
1.66
2.32
3.96
9.60
1.86
2.58
2.58
2.58
9.60
1.65
2.32
2.32
3.31
9.60
2.40
2.40
2.40
2.40
9.60

Note:

(min ~ max)
3.55~10.68
3.82~10.72
4.12~10.75
3.01~10.36
3.28~10.37
3.69~10.68
3.96~10.72
4.26~10.75
3.55~10.38
3.96~10.69
4.23~10.73
4.36~11.00
3.15~10.36
3.42~10.37
3.82~10.68
4.09~10.72
4.39~10.75
3.69~10.38
4.09~10.69
4.36~10.73
4.50~11.00
3.96~10.38
4.36~10.70
3.28~10.36
3.55~10.37
3.96~10.68
4.23~10.72
3.82~10.38
4.23~10.69
4.50~10.73
4.09~10.38
4.50~10.70
4.36~10.39

Total input (kW)


Rating
2.25
2.23
2.22
2.41
2.41
2.25
2.23
2.22
2.40
2.24
2.23
2.09
2.41
2.41
2.25
2.23
2.22
2.40
2.24
2.23
2.09
2.40
2.24
2.41
2.41
2.25
2.23
2.40
2.24
2.23
2.40
2.24
2.40

(min ~ max)
0.58~2.65
0.62~2.64
0.69~2.63
0.57~2.72
0.61~2.72
0.61~2.65
0.64~2.64
0.71~2.63
0.66~2.72
0.67~2.65
0.72~2.64
0.66~2.59
0.59~2.72
0.64~2.72
0.63~2.65
0.69~2.64
0.74~2.63
0.68~2.72
0.70~2.65
0.74~2.64
0.71~2.59
0.73~2.71
0.75~2.65
0.61~2.72
0.66~2.72
0.68~2.65
0.72~2.64
0.71~2.72
0.72~2.65
0.77~2.64
0.76~2.71
0.77~2.65
0.81~2.71

Total current (A)


Rating
10.4
10.3
10.3
11.2
11.2
10.4
10.3
10.3
11.1
10.4
10.3
9.7
11.2
11.2
10.4
10.3
10.3
11.1
10.4
10.3
9.7
11.1
10.4
11.2
11.2
10.4
10.3
11.1
10.4
10.3
11.1
10.4
11.1

(min ~ max)
2.7~12.3
2.9~12.2
3.2~12.2
2.6~12.6
2.8~12.6
2.8~12.3
3.0~12.2
3.3~12.2
3.1~12.6
3.1~12.3
3.3~12.2
3.1~12.0
2.7~12.6
3.0~12.6
2.9~12.3
3.2~12.2
3.4~12.2
3.2~12.6
3.2~12.3
3.4~12.2
3.3~12.0
3.4~12.6
3.5~12.3
2.8~12.6
3.1~12.6
3.2~12.3
3.3~12.2
3.3~12.6
3.3~12.3
3.6~12.2
3.5~12.6
3.6~12.3
3.8~12.6

Power
factor (%)
Rating
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98

1. Cooling capacity is based on 27CDB/19CWB (Indoor temperature), 35CDB (Outdoor temperature).


Heating capacity is based on 20CDB (Indoor temperature), 7CDB/6CWB (Outdoor temperature).
2. The total ability of connected indoor units is up to 14.5kW.
3. It is impossible to connect the indoor unit for one room only.
3D052664#5
3D052664#6
3D052664#7

SUPER MULTI NX E-Series Heat Pump

33

Specifications

EDAU12-722

Cooling [50Hz / 60Hz 230V]


Capacity of each indoor unit
Combination of
indoor unit
2.0
2.5
3.5
5.0
6.0
7.1
2.0+2.0
2.0+2.5
2.0+3.5
2.0+5.0
2.0+6.0
2.0+7.1
2.5+2.5
2.5+3.5
2.5+5.0
2.5+6.0
2.5+7.1
3.5+3.5
3.5+5.0
3.5+6.0
3.5+7.1
5.0+5.0
5.0+6.0
5.0+7.1
6.0+6.0
6.0+7.1
7.1+7.1
2.0+2.0+2.0
2.0+2.0+2.5
2.0+2.0+3.5
2.0+2.0+5.0
2.0+2.0+6.0
2.0+2.0+7.1
2.0+2.5+2.5
2.0+2.5+3.5
2.0+2.5+5.0
2.0+2.5+6.0
2.0+2.5+7.1
2.0+3.5+3.5
2.0+3.5+5.0
2.0+3.5+6.0
2.0+3.5+7.1
2.0+5.0+5.0
2.0+5.0+6.0
2.0+5.0+7.1
2.0+6.0+6.0
2.5+2.5+2.5
2.5+2.5+3.5
2.5+2.5+5.0
2.5+2.5+6.0
2.5+2.5+7.1
2.5+3.5+3.5
2.5+3.5+5.0
2.5+3.5+6.0
2.5+3.5+7.1
2.5+5.0+5.0
2.5+5.0+6.0
2.5+6.0+6.0
3.5+3.5+3.5
3.5+3.5+5.0
3.5+3.5+6.0
3.5+3.5+7.1
3.5+5.0+5.0
3.5+5.0+6.0
2.0+2.0+2.0+2.0
2.0+2.0+2.0+2.5
2.0+2.0+2.0+3.5

34

Each capacity (kW)

Total capacity (kW)

A room B room C room D room Rating


2.00

2.00
2.50

2.50
3.50

3.50
5.00

5.00
6.00

6.00
7.10

7.10
2.00
2.00

4.00
2.00
2.50

4.50
2.00
3.50

5.50
2.00
5.00

7.00
1.83
5.48

7.31
1.66
5.90

7.56
2.50
2.50

5.00
2.50
3.50

6.00
2.40
4.79

7.19
2.18
5.24

7.42
2.00
5.68

7.68
3.50
3.50

7.00
3.06
4.36

7.42
2.82
4.83

7.65
2.61
5.30

7.91
3.88
3.88

7.76
3.64
4.36

8.00
3.31
4.69

8.00
4.00
4.00

8.00
3.66
4.34

8.00
4.00
4.00

8.00
2.00
2.00
2.00

6.00
2.00
2.00
2.50

6.50
1.92
1.92
3.35

7.19
1.68
1.68
4.18

7.54
1.55
1.55
4.67

7.77
1.44
1.44
5.12

8.00
2.00
2.50
2.50

7.00
1.83
2.28
3.20

7.31
1.61
2.01
4.03

7.65
1.50
1.88
4.50

7.88
1.38
1.72
4.90

8.00
1.68
2.93
2.93

7.54
1.50
2.63
3.75

7.88
1.39
2.43
4.18

8.00
1.27
2.22
4.51

8.00
1.34
3.33
3.33

8.00
1.23
3.08
3.69

8.00
1.13
2.84
4.03

8.00
1.14
3.43
3.43

8.00
2.40
2.40
2.40

7.20
2.18
2.18
3.06

7.42
1.94
1.94
3.89

7.77
1.82
1.82
4.36

8.00
1.65
1.65
4.70

8.00
2.01
2.82
2.82

7.65
1.81
2.55
3.64

8.00
1.67
2.33
4.00

8.00
1.52
2.14
4.34

8.00
1.60
3.20
3.20

8.00
1.48
2.96
3.56

8.00
1.38
3.31
3.31

8.00
2.63
2.63
2.63

7.89
2.33
2.33
3.34

8.00
2.15
2.15
3.70

8.00
1.99
1.99
4.02

8.00
2.08
2.96
2.96

8.00
1.93
2.76
3.31

8.00
1.83
1.83
1.83
1.83
7.32
1.75
1.75
1.75
2.17
7.42
1.61
1.61
1.61
2.82
7.65

(min ~ max)
1.80~2.99
1.87~3.52
1.91~4.85
2.07~5.65
2.17~6.60
2.28~7.26
1.97~5.30
2.02~5.73
2.12~6.38
2.27~7.30
2.41~7.90
2.56~8.22
2.07~6.17
2.17~6.60
2.34~7.59
2.48~8.03
2.63~8.22
2.27~7.27
2.48~8.01
2.61~8.54
2.77~8.23
2.68~8.76
2.82~8.79
2.97~8.99
2.96~9.00
3.11~9.02
3.26~9.04
2.17~6.63
2.22~6.95
2.34~7.61
2.55~8.40
2.68~8.82
2.83~9.03
2.27~7.30
2.41~7.90
2.61~8.62
2.75~8.84
2.90~9.03
2.55~8.23
2.75~8.81
2.89~9.02
3.04~9.07
2.96~9.39
3.09~9.54
3.25~9.60
3.23~9.60
2.34~7.61
2.48~8.05
2.68~8.80
2.82~8.84
2.97~9.03
2.61~8.34
2.82~8.81
2.96~9.02
3.11~9.07
3.03~9.47
3.16~9.58
3.30~9.60
2.75~8.58
2.96~8.99
3.09~9.07
3.25~9.05
3.16~9.58
3.30~9.60
2.41~7.90
2.48~8.16
2.61~8.62

Total input (kW)


Rating
0.60
0.78
1.19
1.67
2.01
2.71
1.19
1.36
1.81
2.36
2.53
2.69
1.44
2.01
2.47
2.59
2.73
2.65
2.65
2.70
2.97
2.58
2.71
2.71
2.65
2.59
2.53
1.78
2.03
2.48
2.40
2.53
2.65
2.36
2.54
2.46
2.59
2.65
2.72
2.58
2.59
2.53
2.38
2.32
2.26
2.38
2.48
2.60
2.52
2.65
2.59
2.78
2.71
2.65
2.59
2.38
2.32
2.26
2.90
2.71
2.65
2.59
2.38
2.32
2.11
2.17
2.29

(min ~ max)
0.46~1.07
0.49~1.35
0.49~1.57
0.47~1.81
0.47~2.43
0.50~2.83
0.47~1.67
0.47~1.81
0.47~2.11
0.51~2.53
0.51~2.96
0.54~3.16
0.43~2.11
0.47~2.37
0.51~2.77
0.54~3.03
0.58~3.16
0.50~2.83
0.54~3.03
0.58~3.56
0.61~3.16
0.58~3.24
0.61~3.25
0.65~3.39
0.61~3.39
0.65~3.39
0.68~3.40
0.51~2.09
0.51~2.31
0.51~2.72
0.55~2.97
0.58~3.25
0.61~3.40
0.51~2.54
0.51~2.97
0.55~3.11
0.58~3.25
0.61~3.40
0.54~3.16
0.58~3.25
0.61~3.39
0.65~3.40
0.62~3.33
0.65~3.48
0.65~3.49
0.65~3.49
0.51~2.72
0.54~3.03
0.58~3.24
0.61~3.25
0.61~3.40
0.58~3.09
0.61~3.25
0.61~3.39
0.65~3.40
0.62~3.40
0.65~3.48
0.68~3.49
0.61~3.16
0.61~3.39
0.65~3.39
0.68~3.40
0.65~3.48
0.68~3.49
0.52~2.46
0.55~2.59
0.55~2.91

Total current (A)


Rating
2.7
3.5
5.3
7.4
8.9
12.0
5.3
6.0
8.0
10.5
11.2
11.9
6.4
8.9
11.0
11.5
12.1
11.8
11.8
12.0
13.2
11.4
12.0
12.0
11.8
11.5
11.2
7.9
9.0
11.0
10.6
11.2
11.8
10.5
11.3
10.9
11.5
11.8
12.1
11.4
11.5
11.2
10.6
10.3
10.0
10.6
11.0
11.5
11.2
11.8
11.5
12.3
12.0
11.8
11.5
10.6
10.3
10.0
12.9
12.0
11.8
11.5
10.6
10.3
9.4
9.6
10.2

(min ~ max)
2.0~4.7
2.2~6.0
2.2~7.0
2.1~8.0
2.1~10.8
2.2~12.6
2.1~7.4
2.1~8.0
2.1~9.4
2.3~11.2
2.3~13.1
2.4~14.0
1.9~9.4
2.1~10.5
2.3~12.3
2.4~13.4
2.6~14.0
2.2~12.6
2.4~13.4
2.6~15.8
2.7~14.0
2.6~14.4
2.7~14.4
2.9~15.0
2.7~15.0
2.9~15.0
3.0~15.1
2.3~9.3
2.3~10.2
2.3~12.1
2.4~13.2
2.6~14.4
2.7~15.1
2.3~11.3
2.3~13.2
2.4~13.8
2.6~14.4
2.7~15.1
2.4~14.0
2.6~14.4
2.7~15.0
2.9~15.1
2.8~14.8
2.9~15.4
2.9~15.5
2.9~15.5
2.3~12.1
2.4~13.4
2.6~14.4
2.7~14.4
2.7~15.1
2.6~13.7
2.7~14.4
2.7~15.0
2.9~15.1
2.8~15.1
2.9~15.4
3.0~15.5
2.7~14.0
2.7~15.0
2.9~15.0
3.0~15.1
2.9~15.4
3.0~15.5
2.3~10.9
2.4~11.5
2.4~12.9

Power
factor (%)
Rating
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98

SUPER MULTI NX E-Series Heat Pump

EDAU12-722

Specifications

Capacity of each indoor unit


Combination of
indoor unit
2.0+2.0+2.0+5.0
2.0+2.0+2.0+6.0
2.0+2.0+2.0+7.1
2.0+2.0+2.5+2.5
2.0+2.0+2.5+3.5
2.0+2.0+2.5+5.0
2.0+2.0+2.5+6.0
2.0+2.0+2.5+7.1
2.0+2.0+3.5+3.5
2.0+2.0+3.5+5.0
2.0+2.0+3.5+6.0
2.0+2.0+5.0+5.0
2.0+2.5+2.5+2.5
2.0+2.5+2.5+3.5
2.0+2.5+2.5+5.0
2.0+2.5+2.5+6.0
2.0+2.5+2.5+7.1
2.0+2.5+3.5+3.5
2.0+2.5+3.5+5.0
2.0+2.5+3.5+6.0
2.0+2.5+5.0+5.0
2.0+3.5+3.5+3.5
2.0+3.5+3.5+5.0
2.5+2.5+2.5+2.5
2.5+2.5+2.5+3.5
2.5+2.5+2.5+5.0
2.5+2.5+2.5+6.0
2.5+2.5+3.5+3.5
2.5+2.5+3.5+5.0
2.5+2.5+3.5+6.0
2.5+3.5+3.5+3.5
2.5+3.5+3.5+5.0
3.5+3.5+3.5+3.5

Each capacity (kW)

Total capacity (kW)

A room B room C room D room Rating


1.45
1.45
1.45
3.65
8.00
1.33
1.33
1.33
4.01
8.00
1.22
1.22
1.22
4.34
8.00
1.68
1.68
2.09
2.09
7.54
1.55
1.55
1.94
2.73
7.77
1.39
1.39
1.74
3.48
8.00
1.28
1.28
1.60
3.84
8.00
1.18
1.18
1.47
4.17
8.00
1.45
1.45
2.55
2.55
8.00
1.28
1.28
2.24
3.20
8.00
1.19
1.19
2.07
3.55
8.00
1.14
1.14
2.86
2.86
8.00
1.62
2.01
2.01
2.01
7.65
1.50
1.88
1.88
2.62
7.88
1.33
1.67
1.67
3.33
8.00
1.23
1.54
1.54
3.69
8.00
1.13
1.42
1.42
4.03
8.00
1.40
1.74
2.43
2.43
8.00
1.23
1.54
2.15
3.08
8.00
1.14
1.43
2.00
3.43
8.00
1.10
1.38
2.76
2.76
8.00
1.28
2.24
2.24
2.24
8.00
1.14
2.00
2.00
2.86
8.00
1.94
1.94
1.94
1.94
7.76
1.82
1.82
1.82
2.54
8.00
1.60
1.60
1.60
3.20
8.00
1.48
1.48
1.48
3.56
8.00
1.67
1.67
2.33
2.33
8.00
1.48
1.48
2.07
2.97
8.00
1.38
1.38
1.93
3.31
8.00
1.55
2.15
2.15
2.15
8.00
1.38
1.93
1.93
2.76
8.00
2.00
2.00
2.00
2.00
8.00

Note:

(min ~ max)
2.82~9.15
2.96~9.39
3.11~9.55
2.55~8.40
2.68~8.82
2.89~9.28
3.03~9.47
3.18~9.59
2.82~8.86
3.03~9.47
3.16~9.58
3.23~9.60
2.61~8.62
2.75~8.86
2.96~9.39
3.09~9.54
3.25~9.60
2.89~9.09
3.09~9.54
3.23~9.60
3.30~9.60
3.03~9.23
3.23~9.60
2.68~8.82
2.82~8.92
3.03~9.47
3.16~9.58
2.96~9.04
3.16~9.58
3.30~9.60
3.09~9.34
3.30~9.60
3.23~9.05

Total input (kW)


Rating
2.38
2.32
2.26
2.23
2.53
2.38
2.32
2.26
2.65
2.38
2.32
2.15
2.29
2.59
2.38
2.35
2.32
2.65
2.38
2.32
2.11
2.65
2.38
2.53
2.65
2.38
2.32
2.65
2.38
2.32
2.65
2.38
2.65

(min ~ max)
0.59~3.12
0.62~3.34
0.65~3.42
0.55~2.78
0.58~3.25
0.59~3.26
0.62~3.34
0.65~3.50
0.61~3.25
0.62~3.41
0.65~3.49
0.65~3.11
0.55~2.91
0.58~3.25
0.62~3.34
0.65~3.42
0.65~3.50
0.61~3.40
0.65~3.49
0.65~3.49
0.65~3.11
0.65~3.40
0.65~3.49
0.58~3.25
0.61~3.25
0.62~3.41
0.65~3.49
0.61~3.40
0.65~3.49
0.68~3.49
0.65~3.40
0.68~3.49
0.68~3.40

Total current (A)


Rating
10.6
10.3
10.0
9.9
11.2
10.6
10.3
10.0
11.8
10.6
10.3
9.5
10.2
11.5
10.6
10.4
10.3
11.8
10.6
10.3
9.4
11.8
10.6
11.2
11.8
10.6
10.3
11.8
10.6
10.3
11.8
10.6
11.8

(min ~ max)
2.6~13.8
2.8~14.8
2.9~15.2
2.4~12.3
2.6~14.4
2.6~14.5
2.8~14.8
2.9~15.5
2.7~14.4
2.8~15.1
2.9~15.5
2.9~13.8
2.4~12.9
2.6~14.4
2.8~14.8
2.9~15.2
2.9~15.5
2.7~15.1
2.9~15.5
2.9~15.5
2.9~13.8
2.9~15.1
2.9~15.5
2.6~14.4
2.7~14.4
2.8~15.1
2.9~15.5
2.7~15.1
2.9~15.5
3.0~15.5
2.9~15.1
3.0~15.5
3.0~15.1

Power
factor (%)
Rating
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98

1. Cooling capacity is based on 27CDB/19CWB (Indoor temperature), 35CDB (Outdoor temperature).


Heating capacity is based on 20CDB (Indoor temperature), 7CDB/6CWB (Outdoor temperature).
2. The total ability of connected indoor units is up to 14.5kW.
3. It is impossible to connect the indoor unit for one room only.
3D052665#1
3D052665#2
3D052665#3

SUPER MULTI NX E-Series Heat Pump

35

Specifications

EDAU12-722

Heating [50Hz / 60Hz 230V]


Capacity of each indoor unit
Combination of
indoor unit
2.0
2.5
3.5
5.0
6.0
7.1
2.0+2.0
2.0+2.5
2.0+3.5
2.0+5.0
2.0+6.0
2.0+7.1
2.5+2.5
2.5+3.5
2.5+5.0
2.5+6.0
2.5+7.1
3.5+3.5
3.5+5.0
3.5+6.0
3.5+7.1
5.0+5.0
5.0+6.0
5.0+7.1
6.0+6.0
6.0+7.1
7.1+7.1
2.0+2.0+2.0
2.0+2.0+2.5
2.0+2.0+3.5
2.0+2.0+5.0
2.0+2.0+6.0
2.0+2.0+7.1
2.0+2.5+2.5
2.0+2.5+3.5
2.0+2.5+5.0
2.0+2.5+6.0
2.0+2.5+7.1
2.0+3.5+3.5
2.0+3.5+5.0
2.0+3.5+6.0
2.0+3.5+7.1
2.0+5.0+5.0
2.0+5.0+6.0
2.0+5.0+7.1
2.0+6.0+6.0
2.5+2.5+2.5
2.5+2.5+3.5
2.5+2.5+5.0
2.5+2.5+6.0
2.5+2.5+7.1
2.5+3.5+3.5
2.5+3.5+5.0
2.5+3.5+6.0
2.5+3.5+7.1
2.5+5.0+5.0
2.5+5.0+6.0
2.5+6.0+6.0
3.5+3.5+3.5
3.5+3.5+5.0
3.5+3.5+6.0
3.5+3.5+7.1
3.5+5.0+5.0
3.5+5.0+6.0
2.0+2.0+2.0+2.0
2.0+2.0+2.0+2.5
2.0+2.0+2.0+3.5

36

Each capacity (kW)

Total capacity (kW)

A room B room C room D room Rating


2.44

2.44
3.05

3.05
4.27

4.27
6.09

6.09
7.31

7.31
8.65

8.65
2.44
2.44

4.88
2.44
3.05

5.49
2.44
4.26

6.70
2.44
6.09

8.53
2.32
6.95

9.27
2.11
7.49

9.60
3.04
3.04

6.08
3.05
4.26

7.31
2.98
5.95

8.93
2.82
6.78

9.60
2.50
7.10

9.60
4.26
4.26

8.52
3.95
5.65

9.60
3.54
6.06

9.60
3.17
6.43

9.60
4.80
4.80

9.60
4.36
5.24

9.60
3.97
5.63

9.60
4.80
4.80

9.60
4.40
5.20

9.60
4.80
4.80

9.60
2.43
2.43
2.43

7.29
2.44
2.44
3.04

7.92
2.38
2.38
4.17

8.93
2.13
2.13
5.34

9.60
1.92
1.92
5.76

9.60
1.73
1.73
6.14

9.60
2.43
3.05
3.05

8.53
2.31
2.90
4.06

9.27
2.02
2.53
5.05

9.60
1.82
2.29
5.49

9.60
1.65
2.07
5.88

9.60
2.14
3.73
3.73

9.60
1.83
3.20
4.57

9.60
1.67
2.92
5.01

9.60
1.52
2.67
5.41

9.60
1.60
4.00
4.00

9.60
1.48
3.69
4.43

9.60
1.37
3.40
4.83

9.60
1.38
4.11
4.11

9.60
2.97
2.97
2.97

8.91
2.82
2.82
3.96

9.60
2.40
2.40
4.80

9.60
2.18
2.18
5.24

9.60
1.98
1.98
5.64

9.60
2.52
3.54
3.54

9.60
2.19
3.05
4.36

9.60
2.00
2.80
4.80

9.60
1.84
2.56
5.20

9.60
1.92
3.84
3.84

9.60
1.77
3.56
4.27

9.60
1.66
3.97
3.97

9.60
3.20
3.20
3.20

9.60
2.80
2.80
4.00

9.60
2.58
2.58
4.44

9.60
2.38
2.38
4.84

9.60
2.48
3.56
3.56

9.60
2.32
3.31
3.97

9.60
2.32
2.32
2.32
2.32
9.28
2.26
2.26
2.26
2.82
9.60
2.02
2.02
2.02
3.54
9.60

(min ~ max)
1.31~4.10
1.36~4.55
1.48~4.94
1.90~6.92
2.19~7.92
2.50~8.70
1.62~6.55
1.76~6.85
2.05~7.35
2.47~8.53
2.74~9.35
3.04~10.02
1.90~6.92
2.19~8.24
2.61~9.14
2.88~9.77
3.17~10.02
2.47~8.87
2.88~9.74
3.15~10.00
3.45~10.03
3.28~10.27
3.55~10.31
3.85~10.34
3.82~10.35
4.12~10.38
4.42~10.41
2.19~8.05
2.33~8.64
2.61~9.37
3.01~10.32
3.28~10.35
3.58~10.39
2.47~8.64
2.74~9.37
3.15~10.32
3.42~10.35
3.72~10.39
3.01~10.01
3.42~10.32
3.69~10.36
3.99~10.39
3.82~10.64
4.09~10.67
4.39~10.71
4.36~10.71
2.61~9.55
2.88~9.78
3.28~10.32
3.55~10.35
3.85~10.39
3.15~10.01
3.55~10.32
3.82~10.36
4.12~10.39
3.96~10.64
4.23~10.67
4.50~10.71
3.42~10.02
3.82~10.33
4.09~10.37
4.39~10.40
4.23~10.64
4.50~10.68
2.74~9.45
2.88~9.60
3.15~10.37

Total input (kW)


Rating
0.71
0.93
1.51
1.83
2.32
2.94
1.24
1.43
1.97
2.40
2.59
2.63
1.79
2.26
2.55
2.81
2.66
2.87
2.81
2.64
2.58
2.44
2.43
2.42
2.46
2.45
2.39
1.87
2.08
2.43
2.42
2.41
2.40
2.29
2.56
2.42
2.41
2.40
2.58
2.42
2.41
2.40
2.26
2.25
2.24
2.23
2.48
2.69
2.42
2.41
2.40
2.58
2.42
2.41
2.40
2.26
2.25
2.23
2.58
2.42
2.40
2.39
2.26
2.25
2.41
2.51
2.41

(min ~ max)
0.33~1.29
0.35~1.39
0.36~1.79
0.44~2.23
0.58~2.63
0.62~2.97
0.36~1.85
0.40~1.93
0.46~2.26
0.56~2.40
0.60~2.64
0.64~2.84
0.44~2.17
0.58~2.67
0.58~2.66
0.62~2.94
0.67~2.88
0.63~3.11
0.63~2.87
0.65~2.85
0.72~2.78
0.63~2.76
0.67~2.74
0.71~2.73
0.71~2.78
0.76~2.77
0.83~2.70
0.51~2.17
0.53~2.36
0.58~2.64
0.58~2.74
0.61~2.72
0.66~2.71
0.56~2.34
0.60~2.61
0.60~2.74
0.64~2.72
0.68~2.71
0.62~2.79
0.64~2.74
0.68~2.72
0.73~2.71
0.64~2.67
0.70~2.66
0.74~2.64
0.74~2.64
0.58~2.74
0.62~2.79
0.62~2.74
0.66~2.72
0.70~2.71
0.64~2.79
0.67~2.74
0.71~2.72
0.75~2.71
0.68~2.67
0.73~2.66
0.77~2.64
0.69~2.79
0.71~2.73
0.76~2.72
0.80~2.71
0.73~2.67
0.78~2.65
0.51~2.51
0.55~2.51
0.59~2.72

Total current (A)


Rating
3.1
4.1
6.7
8.1
10.3
13.0
5.5
6.3
8.7
10.6
11.5
11.7
7.9
10.0
11.3
12.5
11.8
12.7
12.5
11.7
11.4
10.8
10.8
10.7
10.9
10.9
10.6
8.3
9.2
10.8
10.7
10.7
10.6
10.2
11.4
10.7
10.7
10.6
11.4
10.7
10.7
10.6
10.0
10.0
9.9
9.9
11.0
11.9
10.7
10.7
10.6
11.4
10.7
10.7
10.6
10.0
10.0
9.9
11.4
10.7
10.6
10.6
10.0
10.0
10.7
11.1
10.7

(min ~ max)
1.5~5.7
1.6~6.2
1.6~7.9
2.0~9.9
2.6~11.7
2.8~13.2
1.6~8.2
1.8~8.6
2.0~10.0
2.5~10.6
2.7~11.7
2.8~12.6
2.0~9.6
2.6~11.8
2.6~11.8
2.8~13.0
3.0~12.8
2.8~13.8
2.8~12.7
2.9~12.6
3.2~12.3
2.8~12.2
3.0~12.2
3.1~12.1
3.1~12.3
3.4~12.3
3.7~12.0
2.3~9.6
2.4~10.5
2.6~11.7
2.6~12.2
2.7~12.1
2.9~12.0
2.5~10.4
2.7~11.6
2.7~12.2
2.8~12.1
3.0~12.0
2.8~12.4
2.8~12.2
3.0~12.1
3.2~12.0
2.8~11.8
3.1~11.8
3.3~11.7
3.3~11.7
2.6~12.2
2.8~12.4
2.8~12.2
2.9~12.1
3.1~12.0
2.8~12.4
3.0~12.2
3.1~12.1
3.3~12.0
3.0~11.8
3.2~11.8
3.4~11.7
3.1~12.4
3.1~12.1
3.4~12.1
3.5~12.0
3.2~11.8
3.5~11.8
2.3~11.1
2.4~11.1
2.6~12.1

Power
factor (%)
Rating
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98

SUPER MULTI NX E-Series Heat Pump

EDAU12-722

Specifications

Capacity of each indoor unit


Combination of
indoor unit
2.0+2.0+2.0+5.0
2.0+2.0+2.0+6.0
2.0+2.0+2.0+7.1
2.0+2.0+2.5+2.5
2.0+2.0+2.5+3.5
2.0+2.0+2.5+5.0
2.0+2.0+2.5+6.0
2.0+2.0+2.5+7.1
2.0+2.0+3.5+3.5
2.0+2.0+3.5+5.0
2.0+2.0+3.5+6.0
2.0+2.0+5.0+5.0
2.0+2.5+2.5+2.5
2.0+2.5+2.5+3.5
2.0+2.5+2.5+5.0
2.0+2.5+2.5+6.0
2.0+2.5+2.5+7.1
2.0+2.5+3.5+3.5
2.0+2.5+3.5+5.0
2.0+2.5+3.5+6.0
2.0+2.5+5.0+5.0
2.0+3.5+3.5+3.5
2.0+3.5+3.5+5.0
2.5+2.5+2.5+2.5
2.5+2.5+2.5+3.5
2.5+2.5+2.5+5.0
2.5+2.5+2.5+6.0
2.5+2.5+3.5+3.5
2.5+2.5+3.5+5.0
2.5+2.5+3.5+6.0
2.5+3.5+3.5+3.5
2.5+3.5+3.5+5.0
3.5+3.5+3.5+3.5

Each capacity (kW)

Total capacity (kW)

A room B room C room D room Rating


1.75
1.75
1.75
4.35
9.60
1.60
1.60
1.60
4.80
9.60
1.47
1.47
1.47
5.19
9.60
2.13
2.13
2.67
2.67
9.60
1.92
1.92
2.40
3.36
9.60
1.67
1.67
2.09
4.17
9.60
1.54
1.54
1.92
4.60
9.60
1.41
1.41
1.76
5.02
9.60
1.75
1.75
3.05
3.05
9.60
1.54
1.54
2.69
3.83
9.60
1.42
1.42
2.49
4.27
9.60
1.37
1.37
3.43
3.43
9.60
2.01
2.53
2.53
2.53
9.60
1.82
2.29
2.29
3.20
9.60
1.60
2.00
2.00
4.00
9.60
1.47
1.85
1.85
4.43
9.60
1.37
1.70
1.70
4.83
9.60
1.67
2.09
2.92
2.92
9.60
1.48
1.85
2.58
3.69
9.60
1.38
1.71
2.40
4.11
9.60
1.32
1.66
3.31
3.31
9.60
1.53
2.69
2.69
2.69
9.60
1.37
2.40
2.40
3.43
9.60
2.40
2.40
2.40
2.40
9.60
2.18
2.18
2.18
3.06
9.60
1.92
1.92
1.92
3.84
9.60
1.78
1.78
1.78
4.26
9.60
2.00
2.00
2.80
2.80
9.60
1.78
1.78
2.49
3.55
9.60
1.66
1.66
2.32
3.96
9.60
1.86
2.58
2.58
2.58
9.60
1.65
2.32
2.32
3.31
9.60
2.40
2.40
2.40
2.40
9.60

Note:

(min ~ max)
3.55~10.68
3.82~10.72
4.12~10.75
3.01~10.36
3.28~10.37
3.69~10.68
3.96~10.72
4.26~10.75
3.55~10.38
3.96~10.69
4.23~10.73
4.36~11.00
3.15~10.36
3.42~10.37
3.82~10.68
4.09~10.72
4.39~10.75
3.69~10.38
4.09~10.69
4.36~10.73
4.50~11.00
3.96~10.38
4.36~10.70
3.28~10.36
3.55~10.37
3.96~10.68
4.23~10.72
3.82~10.38
4.23~10.69
4.50~10.73
4.09~10.38
4.50~10.70
4.36~10.39

Total input (kW)


Rating
2.25
2.23
2.22
2.41
2.41
2.25
2.23
2.22
2.40
2.24
2.23
2.09
2.41
2.41
2.25
2.23
2.22
2.40
2.24
2.23
2.09
2.40
2.24
2.41
2.41
2.25
2.23
2.40
2.24
2.23
2.40
2.24
2.40

(min ~ max)
0.58~2.65
0.62~2.64
0.69~2.63
0.57~2.72
0.61~2.72
0.61~2.65
0.64~2.64
0.71~2.63
0.66~2.72
0.67~2.65
0.72~2.64
0.66~2.59
0.59~2.72
0.64~2.72
0.63~2.65
0.69~2.64
0.74~2.63
0.68~2.72
0.70~2.65
0.74~2.64
0.71~2.59
0.73~2.71
0.75~2.65
0.61~2.72
0.66~2.72
0.68~2.65
0.72~2.64
0.71~2.72
0.72~2.65
0.77~2.64
0.76~2.71
0.77~2.65
0.81~2.71

Total current (A)


Rating
10.0
9.9
9.8
10.7
10.7
10.0
9.9
9.8
10.6
9.9
9.9
9.3
10.7
10.7
10.0
9.9
9.8
10.6
9.9
9.9
9.3
10.6
9.9
10.7
10.7
10.0
9.9
10.6
9.9
9.9
10.6
9.9
10.6

(min ~ max)
2.6~11.8
2.8~11.7
3.1~11.7
2.5~12.1
2.7~12.1
2.7~11.8
2.8~11.7
3.1~11.7
2.9~12.1
3.0~11.8
3.2~11.7
2.9~11.5
2.6~12.1
2.8~12.1
2.8~11.8
3.1~11.7
3.3~11.7
3.0~12.1
3.1~11.8
3.3~11.7
3.1~11.5
3.2~12.0
3.3~11.8
2.7~12.1
2.9~12.1
3.0~11.8
3.2~11.7
3.1~12.1
3.2~11.8
3.4~11.7
3.4~12.0
3.4~11.8
3.6~12.0

Power
factor (%)
Rating
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98

1. Cooling capacity is based on 27CDB/19CWB (Indoor temperature), 35CDB (Outdoor temperature).


Heating capacity is based on 20CDB (Indoor temperature), 7CDB/6CWB (Outdoor temperature).
2. The total ability of connected indoor units is up to 14.5kW.
3. It is impossible to connect the indoor unit for one room only.
3D052665#4
3D052665#5
3D052665#6

SUPER MULTI NX E-Series Heat Pump

37

Specifications

EDAU12-722

Cooling [50Hz 240V]


Capacity of each indoor unit
Combination of
indoor unit
2.0
2.5
3.5
5.0
6.0
7.1
2.0+2.0
2.0+2.5
2.0+3.5
2.0+5.0
2.0+6.0
2.0+7.1
2.5+2.5
2.5+3.5
2.5+5.0
2.5+6.0
2.5+7.1
3.5+3.5
3.5+5.0
3.5+6.0
3.5+7.1
5.0+5.0
5.0+6.0
5.0+7.1
6.0+6.0
6.0+7.1
7.1+7.1
2.0+2.0+2.0
2.0+2.0+2.5
2.0+2.0+3.5
2.0+2.0+5.0
2.0+2.0+6.0
2.0+2.0+7.1
2.0+2.5+2.5
2.0+2.5+3.5
2.0+2.5+5.0
2.0+2.5+6.0
2.0+2.5+7.1
2.0+3.5+3.5
2.0+3.5+5.0
2.0+3.5+6.0
2.0+3.5+7.1
2.0+5.0+5.0
2.0+5.0+6.0
2.0+5.0+7.1
2.0+6.0+6.0
2.5+2.5+2.5
2.5+2.5+3.5
2.5+2.5+5.0
2.5+2.5+6.0
2.5+2.5+7.1
2.5+3.5+3.5
2.5+3.5+5.0
2.5+3.5+6.0
2.5+3.5+7.1
2.5+5.0+5.0
2.5+5.0+6.0
2.5+6.0+6.0
3.5+3.5+3.5
3.5+3.5+5.0
3.5+3.5+6.0
3.5+3.5+7.1
3.5+5.0+5.0
3.5+5.0+6.0
2.0+2.0+2.0+2.0
2.0+2.0+2.0+2.5
2.0+2.0+2.0+3.5

38

Each capacity (kW)

Total capacity (kW)

A room B room C room D room Rating


2.00

2.00
2.50

2.50
3.50

3.50
5.00

5.00
6.00

6.00
7.10

7.10
2.00
2.00

4.00
2.00
2.50

4.50
2.00
3.50

5.50
2.00
5.00

7.00
1.83
5.48

7.31
1.66
5.90

7.56
2.50
2.50

5.00
2.50
3.50

6.00
2.40
4.79

7.19
2.18
5.24

7.42
2.00
5.68

7.68
3.50
3.50

7.00
3.06
4.36

7.42
2.82
4.83

7.65
2.61
5.30

7.91
3.88
3.88

7.76
3.64
4.36

8.00
3.31
4.69

8.00
4.00
4.00

8.00
3.66
4.34

8.00
4.00
4.00

8.00
2.00
2.00
2.00

6.00
2.00
2.00
2.50

6.50
1.92
1.92
3.35

7.19
1.68
1.68
4.18

7.54
1.55
1.55
4.67

7.77
1.44
1.44
5.12

8.00
2.00
2.50
2.50

7.00
1.83
2.28
3.20

7.31
1.61
2.01
4.03

7.65
1.50
1.88
4.50

7.88
1.38
1.72
4.90

8.00
1.68
2.93
2.93

7.54
1.50
2.63
3.75

7.88
1.39
2.43
4.18

8.00
1.27
2.22
4.51

8.00
1.34
3.33
3.33

8.00
1.23
3.08
3.69

8.00
1.13
2.84
4.03

8.00
1.14
3.43
3.43

8.00
2.40
2.40
2.40

7.20
2.18
2.18
3.06

7.42
1.94
1.94
3.89

7.77
1.82
1.82
4.36

8.00
1.65
1.65
4.70

8.00
2.01
2.82
2.82

7.65
1.81
2.55
3.64

8.00
1.67
2.33
4.00

8.00
1.52
2.14
4.34

8.00
1.60
3.20
3.20

8.00
1.48
2.96
3.56

8.00
1.38
3.31
3.31

8.00
2.63
2.63
2.63

7.89
2.33
2.33
3.34

8.00
2.15
2.15
3.70

8.00
1.99
1.99
4.02

8.00
2.08
2.96
2.96

8.00
1.93
2.76
3.31

8.00
1.83
1.83
1.83
1.83
7.32
1.75
1.75
1.75
2.17
7.42
1.61
1.61
1.61
2.82
7.65

(min ~ max)
1.80~2.99
1.87~3.52
1.91~4.85
2.07~5.65
2.17~6.60
2.28~7.26
1.97~5.30
2.02~5.73
2.12~6.38
2.27~7.30
2.41~7.90
2.56~8.22
2.07~6.17
2.17~6.60
2.34~7.59
2.48~8.03
2.63~8.22
2.27~7.27
2.48~8.01
2.61~8.54
2.77~8.23
2.68~8.76
2.82~8.79
2.97~8.99
2.96~9.00
3.11~9.02
3.26~9.04
2.17~6.63
2.22~6.95
2.34~7.61
2.55~8.40
2.68~8.82
2.83~9.03
2.27~7.30
2.41~7.90
2.61~8.62
2.75~8.84
2.90~9.03
2.55~8.23
2.75~8.81
2.89~9.02
3.04~9.07
2.96~9.39
3.09~9.54
3.25~9.60
3.23~9.60
2.34~7.61
2.48~8.05
2.68~8.80
2.82~8.84
2.97~9.03
2.61~8.34
2.82~8.81
2.96~9.02
3.11~9.07
3.03~9.47
3.16~9.58
3.30~9.60
2.75~8.58
2.96~8.99
3.09~9.07
3.25~9.05
3.16~9.58
3.30~9.60
2.41~7.90
2.48~8.16
2.61~8.62

Total input (kW)


Rating
0.60
0.78
1.19
1.67
2.01
2.71
1.19
1.36
1.81
2.36
2.53
2.69
1.44
2.01
2.47
2.59
2.73
2.65
2.65
2.70
2.97
2.58
2.71
2.71
2.65
2.59
2.53
1.78
2.03
2.48
2.40
2.53
2.65
2.36
2.54
2.46
2.59
2.65
2.72
2.58
2.59
2.53
2.38
2.32
2.26
2.38
2.48
2.60
2.52
2.65
2.59
2.78
2.71
2.65
2.59
2.38
2.32
2.26
2.90
2.71
2.65
2.59
2.38
2.32
2.11
2.17
2.29

(min ~ max)
0.46~1.07
0.49~1.35
0.49~1.57
0.47~1.81
0.47~2.43
0.50~2.83
0.47~1.67
0.47~1.81
0.47~2.11
0.51~2.53
0.51~2.96
0.54~3.16
0.43~2.11
0.47~2.37
0.51~2.77
0.54~3.03
0.58~3.16
0.50~2.83
0.54~3.03
0.58~3.56
0.61~3.16
0.58~3.24
0.61~3.25
0.65~3.39
0.61~3.39
0.65~3.39
0.68~3.40
0.51~2.09
0.51~2.31
0.51~2.72
0.55~2.97
0.58~3.25
0.61~3.40
0.51~2.54
0.51~2.97
0.55~3.11
0.58~3.25
0.61~3.40
0.54~3.16
0.58~3.25
0.61~3.39
0.65~3.40
0.62~3.33
0.65~3.48
0.65~3.49
0.65~3.49
0.51~2.72
0.54~3.03
0.58~3.24
0.61~3.25
0.61~3.40
0.58~3.09
0.61~3.25
0.61~3.39
0.65~3.40
0.62~3.40
0.65~3.48
0.68~3.49
0.61~3.16
0.61~3.39
0.65~3.39
0.68~3.40
0.65~3.48
0.68~3.49
0.52~2.46
0.55~2.59
0.55~2.91

Total current (A)


Rating
2.6
3.3
5.1
7.1
8.5
11.5
5.1
5.8
7.7
10.0
10.8
11.4
6.1
8.5
10.5
11.0
11.6
11.3
11.3
11.5
12.6
11.0
11.5
11.5
11.3
11.0
10.8
7.6
8.6
10.5
10.2
10.8
11.3
10.0
10.8
10.5
11.0
11.3
11.6
11.0
11.0
10.8
10.1
9.9
9.6
10.1
10.5
11.1
10.7
11.3
11.0
11.8
11.5
11.3
11.0
10.1
9.9
9.6
12.3
11.5
11.3
11.0
10.1
9.9
9.0
9.2
9.7

(min ~ max)
2.0~4.5
2.1~5.7
2.1~6.7
2.0~7.7
2.0~10.3
2.1~12.0
2.0~7.1
2.0~7.7
2.0~9.0
2.2~10.8
2.2~12.6
2.3~13.4
1.8~9.0
2.0~10.1
2.2~11.8
2.3~12.9
2.5~13.4
2.1~12.0
2.3~12.9
2.5~15.1
2.6~13.4
2.5~13.8
2.6~13.8
2.8~14.4
2.6~14.4
2.8~14.4
2.9~14.5
2.2~8.9
2.2~9.8
2.2~11.6
2.3~12.6
2.5~13.8
2.6~14.5
2.2~10.8
2.2~12.6
2.3~13.2
2.5~13.8
2.6~14.5
2.3~13.4
2.5~13.8
2.6~14.4
2.8~14.5
2.6~14.2
2.8~14.8
2.8~14.8
2.8~14.8
2.2~11.6
2.3~12.9
2.5~13.8
2.6~13.8
2.6~14.5
2.5~13.1
2.6~13.8
2.6~14.4
2.8~14.5
2.6~14.5
2.8~14.8
2.9~14.8
2.6~13.4
2.6~14.4
2.8~14.4
2.9~14.5
2.8~14.8
2.9~14.8
2.2~10.5
2.3~11.0
2.3~12.4

Power
factor (%)
Rating
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98

SUPER MULTI NX E-Series Heat Pump

EDAU12-722

Specifications

Capacity of each indoor unit


Combination of
indoor unit
2.0+2.0+2.0+5.0
2.0+2.0+2.0+6.0
2.0+2.0+2.0+7.1
2.0+2.0+2.5+2.5
2.0+2.0+2.5+3.5
2.0+2.0+2.5+5.0
2.0+2.0+2.5+6.0
2.0+2.0+2.5+7.1
2.0+2.0+3.5+3.5
2.0+2.0+3.5+5.0
2.0+2.0+3.5+6.0
2.0+2.0+5.0+5.0
2.0+2.5+2.5+2.5
2.0+2.5+2.5+3.5
2.0+2.5+2.5+5.0
2.0+2.5+2.5+6.0
2.0+2.5+2.5+7.1
2.0+2.5+3.5+3.5
2.0+2.5+3.5+5.0
2.0+2.5+3.5+6.0
2.0+2.5+5.0+5.0
2.0+3.5+3.5+3.5
2.0+3.5+3.5+5.0
2.5+2.5+2.5+2.5
2.5+2.5+2.5+3.5
2.5+2.5+2.5+5.0
2.5+2.5+2.5+6.0
2.5+2.5+3.5+3.5
2.5+2.5+3.5+5.0
2.5+2.5+3.5+6.0
2.5+3.5+3.5+3.5
2.5+3.5+3.5+5.0
3.5+3.5+3.5+3.5

Each capacity (kW)

Total capacity (kW)

A room B room C room D room Rating


1.45
1.45
1.45
3.65
8.00
1.33
1.33
1.33
4.01
8.00
1.22
1.22
1.22
4.34
8.00
1.68
1.68
2.09
2.09
7.54
1.55
1.55
1.94
2.73
7.77
1.39
1.39
1.74
3.48
8.00
1.28
1.28
1.60
3.84
8.00
1.18
1.18
1.47
4.17
8.00
1.45
1.45
2.55
2.55
8.00
1.28
1.28
2.24
3.20
8.00
1.19
1.19
2.07
3.55
8.00
1.14
1.14
2.86
2.86
8.00
1.62
2.01
2.01
2.01
7.65
1.50
1.88
1.88
2.62
7.88
1.33
1.67
1.67
3.33
8.00
1.23
1.54
1.54
3.69
8.00
1.13
1.42
1.42
4.03
8.00
1.40
1.74
2.43
2.43
8.00
1.23
1.54
2.15
3.08
8.00
1.14
1.43
2.00
3.43
8.00
1.10
1.38
2.76
2.76
8.00
1.28
2.24
2.24
2.24
8.00
1.14
2.00
2.00
2.86
8.00
1.94
1.94
1.94
1.94
7.76
1.82
1.82
1.82
2.54
8.00
1.60
1.60
1.60
3.20
8.00
1.48
1.48
1.48
3.56
8.00
1.67
1.67
2.33
2.33
8.00
1.48
1.48
2.07
2.97
8.00
1.38
1.38
1.93
3.31
8.00
1.55
2.15
2.15
2.15
8.00
1.38
1.93
1.93
2.76
8.00
2.00
2.00
2.00
2.00
8.00

Note:

(min ~ max)
2.82~9.15
2.96~9.39
3.11~9.55
2.55~8.40
2.68~8.82
2.89~9.28
3.03~9.47
3.18~9.59
2.82~8.86
3.03~9.47
3.16~9.58
3.23~9.60
2.61~8.62
2.75~8.86
2.96~9.39
3.09~9.54
3.25~9.60
2.89~9.09
3.09~9.54
3.23~9.60
3.30~9.60
3.03~9.23
3.23~9.60
2.68~8.82
2.82~8.92
3.03~9.47
3.16~9.58
2.96~9.04
3.16~9.58
3.30~9.60
3.09~9.34
3.30~9.60
3.23~9.05

Total input (kW)


Rating
2.38
2.32
2.26
2.23
2.53
2.38
2.32
2.26
2.65
2.38
2.32
2.15
2.29
2.59
2.38
2.35
2.32
2.65
2.38
2.32
2.11
2.65
2.38
2.53
2.65
2.38
2.32
2.65
2.38
2.32
2.65
2.38
2.65

(min ~ max)
0.59~3.12
0.62~3.34
0.65~3.42
0.55~2.78
0.58~3.25
0.59~3.26
0.62~3.34
0.65~3.50
0.61~3.25
0.62~3.41
0.65~3.49
0.65~3.11
0.55~2.91
0.58~3.25
0.62~3.34
0.65~3.42
0.65~3.50
0.61~3.40
0.65~3.49
0.65~3.49
0.65~3.11
0.65~3.40
0.65~3.49
0.58~3.25
0.61~3.25
0.62~3.41
0.65~3.49
0.61~3.40
0.65~3.49
0.68~3.49
0.65~3.40
0.68~3.49
0.68~3.40

Total current (A)


Rating
10.1
9.9
9.6
9.5
10.8
10.1
9.9
9.6
11.3
10.1
9.9
9.1
9.7
11.0
10.1
10.0
9.9
11.3
10.1
9.9
9.0
11.3
10.1
10.8
11.3
10.1
9.9
11.3
10.1
9.9
11.3
10.1
11.3

(min ~ max)
2.5~13.3
2.6~14.2
2.8~14.5
2.3~11.8
2.5~13.8
2.5~13.9
2.6~14.2
2.8~14.9
2.6~13.8
2.6~14.5
2.8~14.8
2.8~13.2
2.3~12.4
2.5~13.8
2.6~14.2
2.8~14.5
2.8~14.9
2.6~14.5
2.8~14.8
2.8~14.8
2.8~13.2
2.8~14.5
2.8~14.8
2.5~13.8
2.6~13.8
2.6~14.5
2.8~14.8
2.6~14.5
2.8~14.8
2.9~14.8
2.8~14.5
2.9~14.8
2.9~14.5

Power
factor (%)
Rating
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98

1. Cooling capacity is based on 27CDB/19CWB (Indoor temperature), 35CDB (Outdoor temperature).


Heating capacity is based on 20CDB (Indoor temperature), 7CDB/6CWB (Outdoor temperature).
2. The total ability of connected indoor units is up to 14.5kW.
3. It is impossible to connect the indoor unit for one room only.
3D052666#1
3D052666#2
3D052666#3

SUPER MULTI NX E-Series Heat Pump

39

Specifications

EDAU12-722

Heating [50Hz 240V]


Capacity of each indoor unit
Combination of
indoor unit
2.0
2.5
3.5
5.0
6.0
7.1
2.0+2.0
2.0+2.5
2.0+3.5
2.0+5.0
2.0+6.0
2.0+7.1
2.5+2.5
2.5+3.5
2.5+5.0
2.5+6.0
2.5+7.1
3.5+3.5
3.5+5.0
3.5+6.0
3.5+7.1
5.0+5.0
5.0+6.0
5.0+7.1
6.0+6.0
6.0+7.1
7.1+7.1
2.0+2.0+2.0
2.0+2.0+2.5
2.0+2.0+3.5
2.0+2.0+5.0
2.0+2.0+6.0
2.0+2.0+7.1
2.0+2.5+2.5
2.0+2.5+3.5
2.0+2.5+5.0
2.0+2.5+6.0
2.0+2.5+7.1
2.0+3.5+3.5
2.0+3.5+5.0
2.0+3.5+6.0
2.0+3.5+7.1
2.0+5.0+5.0
2.0+5.0+6.0
2.0+5.0+7.1
2.0+6.0+6.0
2.5+2.5+2.5
2.5+2.5+3.5
2.5+2.5+5.0
2.5+2.5+6.0
2.5+2.5+7.1
2.5+3.5+3.5
2.5+3.5+5.0
2.5+3.5+6.0
2.5+3.5+7.1
2.5+5.0+5.0
2.5+5.0+6.0
2.5+6.0+6.0
3.5+3.5+3.5
3.5+3.5+5.0
3.5+3.5+6.0
3.5+3.5+7.1
3.5+5.0+5.0
3.5+5.0+6.0
2.0+2.0+2.0+2.0
2.0+2.0+2.0+2.5
2.0+2.0+2.0+3.5

40

Each capacity (kW)

Total capacity (kW)

A room B room C room D room Rating


2.44

2.44
3.05

3.05
4.27

4.27
6.09

6.09
7.31

7.31
8.65

8.65
2.44
2.44

4.88
2.44
3.05

5.49
2.44
4.26

6.70
2.44
6.09

8.53
2.32
6.95

9.27
2.11
7.49

9.60
3.04
3.04

6.08
3.05
4.26

7.31
2.98
5.95

8.93
2.82
6.78

9.60
2.50
7.10

9.60
4.26
4.26

8.52
3.95
5.65

9.60
3.54
6.06

9.60
3.17
6.43

9.60
4.80
4.80

9.60
4.36
5.24

9.60
3.97
5.63

9.60
4.80
4.80

9.60
4.40
5.20

9.60
4.80
4.80

9.60
2.43
2.43
2.43

7.29
2.44
2.44
3.04

7.92
2.38
2.38
4.17

8.93
2.13
2.13
5.34

9.60
1.92
1.92
5.76

9.60
1.73
1.73
6.14

9.60
2.43
3.05
3.05

8.53
2.31
2.90
4.06

9.27
2.02
2.53
5.05

9.60
1.82
2.29
5.49

9.60
1.65
2.07
5.88

9.60
2.14
3.73
3.73

9.60
1.83
3.20
4.57

9.60
1.67
2.92
5.01

9.60
1.52
2.67
5.41

9.60
1.60
4.00
4.00

9.60
1.48
3.69
4.43

9.60
1.37
3.40
4.83

9.60
1.38
4.11
4.11

9.60
2.97
2.97
2.97

8.91
2.82
2.82
3.96

9.60
2.40
2.40
4.80

9.60
2.18
2.18
5.24

9.60
1.98
1.98
5.64

9.60
2.52
3.54
3.54

9.60
2.19
3.05
4.36

9.60
2.00
2.80
4.80

9.60
1.84
2.56
5.20

9.60
1.92
3.84
3.84

9.60
1.77
3.56
4.27

9.60
1.66
3.97
3.97

9.60
3.20
3.20
3.20

9.60
2.80
2.80
4.00

9.60
2.58
2.58
4.44

9.60
2.38
2.38
4.84

9.60
2.48
3.56
3.56

9.60
2.32
3.31
3.97

9.60
2.32
2.32
2.32
2.32
9.28
2.26
2.26
2.26
2.82
9.60
2.02
2.02
2.02
3.54
9.60

(min ~ max)
1.31~4.10
1.36~4.55
1.48~4.94
1.90~6.92
2.19~7.92
2.50~8.70
1.62~6.55
1.76~6.85
2.05~7.35
2.47~8.53
2.74~9.35
3.04~10.02
1.90~6.92
2.19~8.24
2.61~9.14
2.88~9.77
3.17~10.02
2.47~8.87
2.88~9.74
3.15~10.00
3.45~10.03
3.28~10.27
3.55~10.31
3.85~10.34
3.82~10.35
4.12~10.38
4.42~10.41
2.19~8.05
2.33~8.64
2.61~9.37
3.01~10.32
3.28~10.35
3.58~10.39
2.47~8.64
2.74~9.37
3.15~10.32
3.42~10.35
3.72~10.39
3.01~10.01
3.42~10.32
3.69~10.36
3.99~10.39
3.82~10.64
4.09~10.67
4.39~10.71
4.36~10.71
2.61~9.55
2.88~9.78
3.28~10.32
3.55~10.35
3.85~10.39
3.15~10.01
3.55~10.32
3.82~10.36
4.12~10.39
3.96~10.64
4.23~10.67
4.50~10.71
3.42~10.02
3.82~10.33
4.09~10.37
4.39~10.40
4.23~10.64
4.50~10.68
2.74~9.45
2.88~9.60
3.15~10.37

Total input (kW)


Rating
0.71
0.93
1.51
1.83
2.32
2.94
1.24
1.43
1.97
2.40
2.59
2.63
1.79
2.26
2.55
2.81
2.66
2.87
2.81
2.64
2.58
2.44
2.43
2.42
2.46
2.45
2.39
1.87
2.08
2.43
2.42
2.41
2.40
2.29
2.56
2.42
2.41
2.40
2.58
2.42
2.41
2.40
2.26
2.25
2.24
2.23
2.48
2.69
2.42
2.41
2.40
2.58
2.42
2.41
2.40
2.26
2.25
2.23
2.58
2.42
2.40
2.39
2.26
2.25
2.41
2.51
2.41

(min ~ max)
0.33~1.29
0.35~1.39
0.36~1.79
0.44~2.23
0.58~2.63
0.62~2.97
0.36~1.85
0.40~1.93
0.46~2.26
0.56~2.40
0.60~2.64
0.64~2.84
0.44~2.17
0.58~2.67
0.58~2.66
0.62~2.94
0.67~2.88
0.63~3.11
0.63~2.87
0.65~2.85
0.72~2.78
0.63~2.76
0.67~2.74
0.71~2.73
0.71~2.78
0.76~2.77
0.83~2.70
0.51~2.17
0.53~2.36
0.58~2.64
0.58~2.74
0.61~2.72
0.66~2.71
0.56~2.34
0.60~2.61
0.60~2.74
0.64~2.72
0.68~2.71
0.62~2.79
0.64~2.74
0.68~2.72
0.73~2.71
0.64~2.67
0.70~2.66
0.74~2.64
0.74~2.64
0.58~2.74
0.62~2.79
0.62~2.74
0.66~2.72
0.70~2.71
0.64~2.79
0.67~2.74
0.71~2.72
0.75~2.71
0.68~2.67
0.73~2.66
0.77~2.64
0.69~2.79
0.71~2.73
0.76~2.72
0.80~2.71
0.73~2.67
0.78~2.65
0.51~2.51
0.55~2.51
0.59~2.72

Total current (A)


Rating
3.0
4.0
6.4
7.8
9.9
12.5
5.3
6.1
8.4
10.2
11.0
11.2
7.6
9.6
10.8
11.9
11.3
12.2
11.9
11.2
11.0
10.4
10.3
10.3
10.5
10.4
10.2
8.0
8.8
10.3
10.3
10.2
10.2
9.7
10.9
10.3
10.2
10.2
11.0
10.3
10.2
10.2
9.6
9.6
9.5
9.5
10.5
11.4
10.3
10.2
10.2
11.0
10.3
10.2
10.2
9.6
9.6
9.5
11.0
10.3
10.2
10.2
9.6
9.6
10.2
10.7
10.2

(min ~ max)
1.4~5.5
1.5~5.9
1.5~7.6
1.9~9.5
2.5~11.2
2.6~12.6
1.5~7.9
1.7~8.2
2.0~9.6
2.4~10.2
2.6~11.2
2.7~12.1
1.9~9.2
2.5~11.4
2.5~11.3
2.6~12.5
2.8~12.2
2.7~13.2
2.7~12.2
2.8~12.1
3.1~11.8
2.7~11.7
2.8~11.6
3.0~11.6
3.0~11.8
3.2~11.8
3.5~11.5
2.2~9.2
2.3~10.0
2.5~11.2
2.5~11.6
2.6~11.6
2.8~11.5
2.4~9.9
2.6~11.1
2.6~11.6
2.7~11.6
2.9~11.5
2.6~11.9
2.7~11.6
2.9~11.6
3.1~11.5
2.7~11.4
3.0~11.3
3.1~11.2
3.1~11.2
2.5~11.6
2.6~11.9
2.6~11.6
2.8~11.6
3.0~11.5
2.7~11.9
2.8~11.6
3.0~11.6
3.2~11.5
2.9~11.4
3.1~11.3
3.3~11.2
2.9~11.9
3.0~11.6
3.2~11.6
3.4~11.5
3.1~11.4
3.3~11.3
2.2~10.7
2.3~10.7
2.5~11.6

Power
factor (%)
Rating
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98

SUPER MULTI NX E-Series Heat Pump

EDAU12-722

Specifications

Capacity of each indoor unit


Combination of
indoor unit
2.0+2.0+2.0+5.0
2.0+2.0+2.0+6.0
2.0+2.0+2.0+7.1
2.0+2.0+2.5+2.5
2.0+2.0+2.5+3.5
2.0+2.0+2.5+5.0
2.0+2.0+2.5+6.0
2.0+2.0+2.5+7.1
2.0+2.0+3.5+3.5
2.0+2.0+3.5+5.0
2.0+2.0+3.5+6.0
2.0+2.0+5.0+5.0
2.0+2.5+2.5+2.5
2.0+2.5+2.5+3.5
2.0+2.5+2.5+5.0
2.0+2.5+2.5+6.0
2.0+2.5+2.5+7.1
2.0+2.5+3.5+3.5
2.0+2.5+3.5+5.0
2.0+2.5+3.5+6.0
2.0+2.5+5.0+5.0
2.0+3.5+3.5+3.5
2.0+3.5+3.5+5.0
2.5+2.5+2.5+2.5
2.5+2.5+2.5+3.5
2.5+2.5+2.5+5.0
2.5+2.5+2.5+6.0
2.5+2.5+3.5+3.5
2.5+2.5+3.5+5.0
2.5+2.5+3.5+6.0
2.5+3.5+3.5+3.5
2.5+3.5+3.5+5.0
3.5+3.5+3.5+3.5

Each capacity (kW)

Total capacity (kW)

A room B room C room D room Rating


1.75
1.75
1.75
4.35
9.60
1.60
1.60
1.60
4.80
9.60
1.47
1.47
1.47
5.19
9.60
2.13
2.13
2.67
2.67
9.60
1.92
1.92
2.40
3.36
9.60
1.67
1.67
2.09
4.17
9.60
1.54
1.54
1.92
4.60
9.60
1.41
1.41
1.76
5.02
9.60
1.75
1.75
3.05
3.05
9.60
1.54
1.54
2.69
3.83
9.60
1.42
1.42
2.49
4.27
9.60
1.37
1.37
3.43
3.43
9.60
2.01
2.53
2.53
2.53
9.60
1.82
2.29
2.29
3.20
9.60
1.60
2.00
2.00
4.00
9.60
1.47
1.85
1.85
4.43
9.60
1.37
1.70
1.70
4.83
9.60
1.67
2.09
2.92
2.92
9.60
1.48
1.85
2.58
3.69
9.60
1.38
1.71
2.40
4.11
9.60
1.32
1.66
3.31
3.31
9.60
1.53
2.69
2.69
2.69
9.60
1.37
2.40
2.40
3.43
9.60
2.40
2.40
2.40
2.40
9.60
2.18
2.18
2.18
3.06
9.60
1.92
1.92
1.92
3.84
9.60
1.78
1.78
1.78
4.26
9.60
2.00
2.00
2.80
2.80
9.60
1.78
1.78
2.49
3.55
9.60
1.66
1.66
2.32
3.96
9.60
1.86
2.58
2.58
2.58
9.60
1.65
2.32
2.32
3.31
9.60
2.40
2.40
2.40
2.40
9.60

Note:

(min ~ max)
3.55~10.68
3.82~10.72
4.12~10.75
3.01~10.36
3.28~10.37
3.69~10.68
3.96~10.72
4.26~10.75
3.55~10.38
3.96~10.69
4.23~10.73
4.36~11.00
3.15~10.36
3.42~10.37
3.82~10.68
4.09~10.72
4.39~10.75
3.69~10.38
4.09~10.69
4.36~10.73
4.50~11.00
3.96~10.38
4.36~10.70
3.28~10.36
3.55~10.37
3.96~10.68
4.23~10.72
3.82~10.38
4.23~10.69
4.50~10.73
4.09~10.38
4.50~10.70
4.36~10.39

Total input (kW)


Rating
2.25
2.23
2.22
2.41
2.41
2.25
2.23
2.22
2.40
2.24
2.23
2.09
2.41
2.41
2.25
2.23
2.22
2.40
2.24
2.23
2.09
2.40
2.24
2.41
2.41
2.25
2.23
2.40
2.24
2.23
2.40
2.24
2.40

(min ~ max)
0.58~2.65
0.62~2.64
0.69~2.63
0.57~2.72
0.61~2.72
0.61~2.65
0.64~2.64
0.71~2.63
0.66~2.72
0.67~2.65
0.72~2.64
0.66~2.59
0.59~2.72
0.64~2.72
0.63~2.65
0.69~2.64
0.74~2.63
0.68~2.72
0.70~2.65
0.74~2.64
0.71~2.59
0.73~2.71
0.75~2.65
0.61~2.72
0.66~2.72
0.68~2.65
0.72~2.64
0.71~2.72
0.72~2.65
0.77~2.64
0.76~2.71
0.77~2.65
0.81~2.71

Total current (A)


Rating
9.6
9.5
9.4
10.2
10.2
9.6
9.5
9.4
10.2
9.5
9.5
8.9
10.2
10.2
9.6
9.5
9.4
10.2
9.5
9.5
8.9
10.2
9.5
10.2
10.2
9.6
9.5
10.2
9.5
9.5
10.2
9.5
10.2

(min ~ max)
2.5~11.3
2.6~11.2
2.9~11.2
2.4~11.6
2.6~11.6
2.6~11.3
2.7~11.2
3.0~11.2
2.8~11.6
2.8~11.3
3.1~11.2
2.8~11.0
2.5~11.6
2.7~11.6
2.7~11.3
2.9~11.2
3.1~11.2
2.9~11.6
3.0~11.3
3.1~11.2
3.0~11.0
3.1~11.5
3.2~11.3
2.6~11.6
2.8~11.6
2.9~11.3
3.1~11.2
3.0~11.6
3.1~11.3
3.3~11.2
3.2~11.5
3.3~11.3
3.4~11.5

Power
factor (%)
Rating
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98
98

1. Cooling capacity is based on 27CDB/19CWB (Indoor temperature), 35CDB (Outdoor temperature).


Heating capacity is based on 20CDB (Indoor temperature), 7CDB/6CWB (Outdoor temperature).
2. The total ability of connected indoor units is up to 14.5kW.
3. It is impossible to connect the indoor unit for one room only.
3D052666#4
3D052666#5
3D052666#6

SUPER MULTI NX E-Series Heat Pump

41

Dimensions

EDAU12-722

4. Dimensions
4.1

Indoor Units

4.1.1

Wall Mounted Type

THE MARK () SHOWS PIPING DIRECTION

AIR FLOW( INDOOR )


30MIN.

REAR

( SPACE FOR
PERFORMANCE )

FTXS20DVMA, FTXS25EVMA, FTXS35EVMA

800
RIGHT

LEFT

( INCLUDING
MOUNTING PLATE )

50MIN.

50MIN.

197

( SPACE FOR
MAINTENANCE )

195

( SPACE FOR
MAINTENANCE )

REQUIRED SPACE

SIGNAL RECEIVER

TIMER LAMP
INTELLIGENT EYE LAMP

283

NAME PLATE
OPERATION LAMP

TERMINAL BLOCK
WITH EARTH
TERMINAL

INTELLIGENT EYE SENSOR


BOTTOM

GAS PIPE 9.5Cut


( THE LENGTH OF PIPE OUTSIDE
THEUNIT:ABOUT390 )

DRAIN HOSE
( CONNECTING PART
I. D.14
LIQUID PIPE 6.4CuT
O. D.18
( THE LENGTH OF PIPE OUTSIDE THE HOSE LENGTH OF OUTSIDE
THE UNIT:ABOUT 340 )
THE UNIT IS APPROX. 440 )

INDOOR UNIT ON/OFF SWITCH


FRONT PANEL FIXED SCREWS
FLAPS
( INSIDE )

ROOM TEMP. THERMISTOR( INSIDE )

SIGNAL TRANSMITTER

58

711

17

BLADE ANGLE

18

13

800
49

UP/DOWN( AUTOMATIC )

163

FAN

110

60
WALL HOLE FOR EMBEDDED PIPING
65 HOLE

30

50

70

65

44.5

10

WALL HOLE
65 HOLE

STANDARD LOCATIONS OF WALL HOLES

RIGHT/LEFT( MANUAL )

WIRELESS REMOTE CONTROLLER

283

HEATING

44.5

COOLING, DRY

180

DAIKIN

( ARC433B46 )

3D047956D

45

45

AIR FLOW(INDOOR)
(FOR PERFORMANCE AND MAINTENANCE)

THE MARK () SHOWS PIPING DIRECTION


REAR

REAR

1050

LEFT

RIGHT

(SPACE FOR
MAINTENANCE)
MIN. 50

MIN. 50
(SPACE FOR
MAINTENANCE)

REQUIRED SPACE

INCLUDING
( INSTALLATION
PLATE )

MIN. 30
(SPACE FOR
PERFORMANCE)

FTXS50FVMA, FTXS60FVMA

240
238
OPERATION LAMP
SIGNAL RECEIVER

FLAPS

MODEL NAME
PLATE
290

INDOOR UNIT ON/OFF


SWITCH

TERMINAL BLOCK WITH


EARTH TERMINAL
(INSIDE)

ROOM TEMP. THERMISTOR


(INSIDE)
INTELLIGENT EYE SENSOR
TIMER LAMP
HOME LEAVE LAMP

FRONT GRILLE FIXING SCREWS


(INSIDE)

GAS PIPE 12.7 CuT


(THE LENGTH OF PIPE OUTSIDE
THE UNIT : ABOUT 430)

DRAIN HOSE FOR VP13


(CONNECTING PART
I.D.14.0,O.D.18.0)
(THE HOSE LENGTH OF
OUTSIDE THE UNIT :
LIQUID PIPE 6.4 CuT
(THE LENGTH OF PIPE OUTSIDE ABOUT 530)
THE UNIT : ABOUT 480)

SIGNAL
TRANSMITTER

1050

BLADE ANGLES

893.5

COOLING

HEATING

30

52.5

DRY

10

CONTROLLER
(ARC433B70)

35

55

VERTICAL BLADE(AUTOMATIC)

5
5

50

55

50

60
WALL HOLE FOR
EMBEDDED PIPING
80 HOLE

99.5

52

55

FAN

55

42

35 5

15
40

WIRELESS REMOTE

15

40 10

52

163

155.5
290

HORIZONTAL BLADE
(AUTOMATIC)

14.5

58

18

WALL HOLE
80 HOLE

STANDARD LOCATIONS OF WALL HOLES

3D054935A

SUPER MULTI NX E-Series Heat Pump

EDAU12-722

Dimensions

AIR FLOW(INDOOR)
(FOR PERFORMANCE AND MAINTENANCE)
THE MARK () SHOWS PIPING DIRECTION
REAR

REAR

1050

LEFT

RIGHT
(SPACE FOR
MAINTENANCE)
MIN. 50

MIN. 50
(SPACE FOR
MAINTENANCE)

REQUIRED SPACE

INCLUDING
(INSTALLATION
PLATE)

MIN. 30
(SPACE FOR
PERFORMANCE)

FTXS71FVMA

240
238
OPERATION LAMP
SIGNAL RECEIVER

MODEL NAME
PLATE
290

INDOOR UNIT ON/OFF


SWITCH

FRONT GRILLE FIXING SCREWS


(INSIDE)

FLAPS

TERMINAL BLOCK WITH


EARTH TERMINAL
(INSIDE)

ROOM TEMP. THERMISTOR


(INSIDE)
INTELLIGENT EYE SENSOR
TIMER LAMP
HOME LEAVE LAMP

GAS PIPE 15.9 CuT


(THE LENGTH OF PIPE OUTSIDE
THE UNIT : ABOUT 430)

DRAIN HOSE FOR VP13


(CONNECTING PART
I.D.14.0,O.D.18.0)
(THE HOSE LENGTH OF
OUTSIDE THE UNIT :
LIQUID PIPE 6.4 CuT
(THE LENGTH OF PIPE OUTSIDE ABOUT 530)
THE UNIT : ABOUT 480)

SIGNAL
TRANSMITTER

1050

18

BLADE ANGLES

893.5

30

52.5

DRY

10

CONTROLLER
(ARC433B70)

35 5

15
55

FAN

35

55

5
5
55

4.1.2

60

VERTICAL BLADE(AUTOMATIC)

WALL HOLE FOR


EMBEDDED PIPING
80 HOLE

50

50

52

40

WIRELESS REMOTE

15

40 10

52

163

155.5

HEATING

290

HORIZONTAL BLADE
(AUTOMATIC)
COOLING

14.5

58

99.5

WALL HOLE
80 HOLE

STANDARD LOCATIONS OF WALL HOLES

3D054936A

55

Duct Connected Type

FDXS25CVMA, FDXS35CVMA, FDXS50CVMA

163
900

(72)

38

DAIKIN

HOME LEAVE
LAMP

SIGNAL RECEIVER
CORD(LENGTH:1900mm)

1
20-M5 HOLES
(ALL AROUND)

INFRARED RECEIVER UNIT

10

23

100
160
180

90

TIMER LAMP
INDOOR UNIT
ON/OFF SWITCH

170

47
90

130 63

(20)

70

120

ALLOW VIEW
INSPECTION DOOR
(CEILING OPENING)

ROOM TEMP.
SENSOR

OPERATION LAMP

50
20
10

240 OR MORE
SERVICE SPACE

WIRELESS REMOTE CONTROLLER


FDXS--CVMA : (ARC433A69)

(45)

100

90

880
860
4xP150=600

400 OR MORE
(IN CASE OF
BOTTOM SUCSION)

CEILING

200
170
153
80

12.5
21
57.5

SUSPENSION BOLT
4-M8~M10

DAIKIN

300

(ALL AROUND)
22-4.7 HOLE
8xP100=800
940
(SUSPENSION BOLT PITCH)

SIGNAL TRANSMITTER
18

58

620

60

620

500
(SUSPENSION BOLT PITCH)

300 OR MORE
(SERVICE SPACE)

20 OR MORE
20 OR MORE

900

18-M4 HOLES
(ALL AROUND)

30

330

20-M5 HOLES
(ALL AROUND)

200
180
160
100

10

10
20
50

7xP100=700
130
780
100
800
90
80
820
IN CASE OF BOTTOM-SUCTION

SUPER MULTI NX E-Series Heat Pump

150
100
90
80

7xP100=700
780
9
800
820
IN CASE OF BACK-SUCTION
10 PROTECTION NET
NOTE) 1. IN CASE OF BACK-SUCTION,
MOUNT CHAMBER COVER TO BOTTOM SIDE OF THE UNIT.
9 AIR FILTER(STANDARD ACCESSORY)
IN CASE OF BOTTOM-SUCTION,
8 SUSPENSION BRACKET
MOUNT CHAMBER COVER TO BACK SIDE OF THE UNIT.
2. LOCATION OF UNITS NAME PLATE : CONTROL BOX COVER
7 POWER SUPPLY CONNECTION
3. MOUNT THE AIR FILTER AT THE SUCTION SIDE.
6 INFRARED RECEIVER UNIT CONNECTION
SELECT ITS COLORIMETHOD(GRAVITY METHOD)
5 CONTROL BOX
50% OR MORE.
IT CAN NOT BE EQUIPPED WITH AIR FILTER(ACCESSORY)
4 DRAIN HOSE(STANDARD ACCESSORY) I.D. 25(OUTLET)
WHEN CONNECTING DUCT TO SUCTION SIDE.
3 SOCKET FOR DRAIN VP20 (O.D. 26/I.D. 20)
4. PIPE SPECIFICATION
FDXS25
2 GAS PIPE CONNECTION NOTE) 4.
9.5 (FLARE CONNECTION)
FDXS35
1 LIQUID PIPE CONNECTION 6.4 FLARE (CONNECTION)
FDXS50 12.7 (FLARE CONNECTION)
NUMBER
NAME
DESCRIPTION
3

3D054289A

43

Dimensions

EDAU12-722

FDXS60CVMA
620
20 OR MORE
20 OR MORE

163

240 OR MORE
CEILING

WIRELESS REMOTE CONTROLLER


FDXS--CVMA : (ARC433A69)

(45)

130 63

(20)

38

(72)

TIMER LAMP
INDOOR UNIT
ON/OFF SWITCH

DAIKIN

HOME LEAVE
LAMP
INFRARED RECEIVER UNIT

SIGNAL RECEIVER
CORD(LENGTH:1900mm)

24-M5 HOLES
(ALL AROUND)

10

100
160
180

23

100

170

47
90

70

50
20
10

ALLOW VIEW
INSPECTION DOOR
(CEILING OPENING)

ROOM TEMP.
SENSOR

OPERATION LAMP

120

300

SERVICE SPACE

200
170
153
80

12.5
21
57.5

DAIKIN

60

620

(ALL AROUND)
26-4.7 HOLE
10xP100=1000
1140
(SUSPENSION BOLT PITCH)
SUSPENSION BOLT
4-M8~M10
1080
1060
6xP150=900

SIGNAL TRANSMITTER
18

58

400 OR MORE
(IN CASE OF
BOTTOM SUCSION)

1100

300 OR MORE
(SERVICE SPACE)
500
(SUSPENSION BOLT PITCH)

1100

18-M4 HOLES
(ALL AROUND)

330

30

9xP100=900
980
1000
1020
IN CASE OF BACK-SUCTION

150
100
90
80

24-M5 HOLES NOTE) 1. IN CASE OF BACK-SUCTION,


MOUNT CHAMBER COVER TO BOTTOM SIDE OF THE UNIT.
(ALL AROUND)
IN CASE OF BOTTOM-SUCTION,
MOUNT CHAMBER COVER TO BACK SIDE OF THE UNIT.
2. LOCATION OF UNITS NAME PLATE : CONTROL BOX COVER
3. MOUNT THE AIR FILTER AT THE SUCTION SIDE.
SELECT ITS COLORIMETHOD(GRAVITY METHOD)
50% OR MORE.
10
IT CAN NOT BE EQUIPPED WITH AIR FILTER(ACCESSORY)
WHEN CONNECTING DUCT TO SUCTION SIDE.
6

10
20
50

200
180
160
100

130
100
90
80

9xP100=900
980
1000
1020

10
9
8
7
6
5
4
3
2
1
NUMBER

PROTECTION NET
AIR FILTER(STANDARD ACCESSORY)
SUSPENSION BRACKET
POWER SUPPLY CONNECTION
INFRARED RECEIVER UNIT CONNECTION
CONTROL BOX
DRAIN HOSE(STANDARD ACCESSORY)
SOCKET FOR DRAIN
GAS PIPE CONNECTION
LIQUID PIPE CONNECTION
NAME

I.D. 25(OUTLET)
VP20 (O.D. 26/I.D. 20)
12.7 (FLARE CONNECTION)
6.4 FLARE (CONNECTION)
DESCRIPTION

3D054290A

IN CASE OF BOTTOM-SUCTION

CDXS25EAVMA, CDXS35EAVMA
300 OR MORE
(SERVICE SPACE)

(ALL AROUND)
16-4.7 HOLE
5P100=500
740
(SUSPENSION BOLT PITCH)

163
700
300

SERVICE SPACE

OPERATION LAMP

70

ROOM TEMP.
SENSOR (20)

FDXS25,35EAVMB(ARC433A7)
FDKS25,35EAVMB(ARC433A8)
CDXS25,35EAVMA(ARC433A7)
CDKS25,35EAVMA(ARC433A8)
CDXS25,35EAVMT(ARC433A59)
CDKS25,35EAVMT(ARC433A60)

38

130 63

HOME LEAVE
LAMP

16-M5 HOLES
(ALL AROUND)

10 9

100

(72)
SIGNAL RECEIVER
CORD(LENGTH:1900mm)

23

200
170
153
80

DAIKIN

INFRARED RECEIVER UNIT

47
90

TIMER LAMP
INDOOR UNIT
ON/OFF SWITCH

50
20
10

INSPECTION DOOR
(CEILING OPENING)

120

ALLOW VIEW

680
660
4P150=600

12.5
21
57.5

WIRELESS REMOTE CONTROLLER


(45)

100
160
180

SUSPENSION BOLT
4-M8~M10

400 OR MORE
(IN CASE OF
BOTTOM SUCSION)

170

SIGNAL TRANSMITTER
18

DAIKIN

CEILING

60

620

500
(SUSPENSION BOLT PITCH)

20 OR MORE
20 OR MORE

58
620

240 OR MORE

700

30

14-M4 HOLES
(ALL AROUND)

330

140
100
90
80

5P100=500
580
600
620

IN CASE OF BACK-SUCTION

200
180
160
100

10
20
50

10 5P100=500

16-M5 HOLES
(ALL AROUND)

44

NOTE) 1. IN CASE OF BACK-SUCTION,


MOUNT CHAMBER COVER TO BOTTOM SIDE OF THE UNIT.
IN CASE OF BOTTOM-SUCTION,
MOUNT CHAMBER COVER TO BACK SIDE OF THE UNIT.
2. LOCATION OF UNITS NAME PLATE: CONTROL BOX COVER
3. MOUNT THE AIR FILTER AT THE SUCTION SIDE.
SELECT ITS COLORIMETHOD(GRAVITY METHOD)
50% OR MORE.
IT CAN NOT BE EQUIPPED WITH AIR FILTER(ACCESSORY)
WHEN CONNECTING DUCT TO SUCTION SIDE.
4. PIPE SPECIFICATION

140
580
100
600
90
80
620
IN CASE OF BOTTOM-SUCTION

10
9
8
7
6
5
4
3
2
1
NUMBER

PROTECTION NET
AIR FILTER(ACCESSORY)
SUSPENSION BRACKET
POWER SUPPLY CONNECTION
INFRARED RECEIVER UNIT CONNECTION
CONTROL BOX
DRAIN HOSE(ACCESSORY)
SOCKET FOR DRAIN
GAS PIPE CONNECTION
LIQUID PIPE CONNECTION
NAME

I.D.25(OUTLET)
VP20(O.D.26/I.D.20)
9.5(FLARE CONNECTION)
6.4(FLARE CONNECTION)
DESCRIPTION

3D050379A

SUPER MULTI NX E-Series Heat Pump

EDAU12-722

4.1.3

Dimensions

Floor / Ceiling Suspended Dual Type

FLXS25BVMA, FLXS35BVMA (In Case of Ceiling)


CEILING SUSPENDED INSTALLATION
THE MARK () SHOWS PIPING DIRECTION

REQUIRED SPACE(CEILING SUSPENDED)


(FOR PERFORMANCE AND
MAINTENANCE)

REAR

1030

AIR FLOW (INDOOR)

50

(SPACE FOR
MAINTENANCE)

(SPACE FOR
MAINTENANCE)

LIQUID PIPE(6.4 CuT)


GAS PIPE(9.5 CuT)

200

FLAP

200MIN

200MIN
RIGHT

490

1050

NAME PLATE

TERMINAL BLOCK
(WITH EARTH TERMINAL)

SUCTION GRILLE

FRONT PANEL
FIXED SCREWS
ROOM TEMP.SENSOR
SIGNAL TRANSMITTER

40 DRAIN HOSE HOLE


DRAIN HOSE (I.D 14, O.D. 18)

STANDARD LOCATIONS OF WALL HOLES

OPERATION LAMP

18

58

RIGHT/LEFT:(MANUAL)
HEATING

DRY

490
65

40

40

20

20

WIRELESS REMOTE CONTROLLER

138

FLAP

95

230

163

UP/DOWN:(AUTOMATIC)
COOLING

WALL HOLE
FOR EMBEDDED PIPING
65 HOLE

1050
980

BLADE ANGLE

DAIKIN

170MIN

50

INDOOR UNIT ON/OFF SWICH


SIGNAL RECEIVER
HOME LEAVE LAMP
TIMER LAMP

40

UNDER

40

WALL HOLE FOR REFRIGERANT PIPING


65 HOLE
55

45

45

ARC433B67

50MIN
(SPACE FOR
MAINTENANCE)

55
LOCATION OF SUSPENSION BOLTS

3D033694E

FLXS25BVMA, FLXS35BVMA (In Case of Floor)


REQUIRED SPACE
(FOR PERFORMANCE AND MAINTENANCE)

FLOOR LEVEL INSTALLATION


THE MARK () SHOWS PIPING DIRECTION

AIR FLOW(INDOOR)

REAR
1030

200MIN
(SPACE FOR
MAINTENANCE)

200MIN
(SPACE FOR
MAINTENANCE)
50

RIGHT

200
FLAP

1050

50MIN
(SPACE FOR
MAINTENANCE)

LIQUID PIPE(6.4 CuT)


GAS PIPE(9.5 CuT)
490

DRAIN HOSE(I.D.14,O.D.18)
NAME PLATE

SUCTION GRILLE
TERMINAL BLOCK
(WITH EARTH TERMINAL)

FRONT PANEL
FIXED SCREWS

SIGNAL TRANSMITTER
18

20

WALL HOLE
FOR EMBEDDED PIPING
80 HOLE

490
162

RIGHT/LEFT:(MANUAL)

255

20

40

40

HEATING

95

163

1050
800

BLADE ANGLE
UP/DOWN:(AUTOMATIC)
COOLING
DRY

DAIKIN

40

ROOM TEMP. SENSOR

58

WALL HOLE FOR REFRIGERANT PIPING


80 HOLE
55

INDOOR UNIT ON/OFF SWICH


SIGNAL RECEIVER
HOME LEAVE LAMP
TIMER LAMP
OPERATION LAMP

40

UNDER

55

45

WIRELESS REMOTE CONTROLLER


ARC433B67
FLAP

SUPER MULTI NX E-Series Heat Pump

45

STANDARD LOCATIONS OF WALL HOLES

50MIN
(SPACE FOR
MAINTENANCE)

3D033695F

45

Dimensions

EDAU12-722

FLXS50BVMA, FLXS60BVMA (In Case of Ceiling)


CEILING SUSPENDED INSTALLATION

REQUIRED SPACE (CEILING SUSPENDED)

THE MARK () SHOWS PIPING DIRECTION

200MIN
(SPACE FOR
MAINTENANCE)

50

RIGHT

200MIN
(SPACE FOR
MAINTENANCE)
LIQUID PIPE (6.4 CuT)
GAS PIPE (12.7 CuT)

200

FLAP

AIR FLOW(INDOOR)

(FOR PERFORMANCE AND


MAINTENANCE)

REAR

1030

490

1050

WALL HOLE FOR REFRIGERANT PIPING


55
65 HOLE

SUCTION GRILLE

50

170MIN

40

NAME PLATE

TERMINAL BLOCK
(WITH EARTH TERMINAL)
INDOOR UNIT ON/OFF SWITCH
SIGNAL RECEIVER
HOME LEAVE LAMP
TIMER LAMP

UNDER
FRONT PANEL
FIXED SCREWS
ROOM TEMP.SENSOR
SIGNAL TRANSMITTER
58

40 DRAIN HOSE HOLE


DRAIN HOSE (I.D. 14, O.D. 18)

STANDARD LOCATIONS OF WALL HOLES

OPERATION LAMP

WALL HOLE
FOR EMBEDDED PIPING
65 HOLE

1050
980

18

BLADE ANGLE
UP/DOWN: (AUTOMATIC)

RIGHT/LEFT: (MANUAL)
HEATING

FLAP

40

DRY

490

163

COOLING

138 230

DAIKIN

65

20
40

20
40

50MIN
(SPACE FOR
MAINTENANCE)

95

WIRELESS REMOTE CONTROLLER

45

45

ARC433B67

55

LOCATION OF SUSPENSION BOLTS

3D050610A

FLXS50BVMA, FLXS60BVMA (In Case of Floor)


FLOOR LEVEL INSTLLATION

REQUIRED SPACE

THE MARK () SHOWS PIPING DIRECTION

AIR FLOW (INDOOR)

(FOR PERFORMANCE AND MAINTENANCE)

REAR

50

1030
200MIN
(SPACE FOR
MAINTENANCE)

200MIN
(SPACE FOR
MAINTENANCE)

RIGHT
200

FLAP

1050

490

50MIN
(SPACE FOR
MAINTENANCE)

NAME PLATE

LIQUID PIPE (6.4 CuT)


GAS PIPE (12.7 CuT)
DRAIN HOSE (I.D. 14, O.D. 18)

SUCTION GRILLE

FRONT PANEL
FIXED SCREWS

SIGNAL TRANSMITTER
18

20

WALL HOLE
FOR EMBEDDED PIPING
80 HOLE

RIGHT/LEFT : (MANUAL)

490
162

40

HEATING

255

40

40

95

163

1050
800

BLADE ANGLE
UP/DOWN : (AUTOMATIC)
COOLING
DRY

DAIKIN

40

INDOOR UNIT ON/OFF SWITCH


SIGNAL RECEIVER
HOME LEAVE LAMP
TIMER LAMP
OPERATION LAMP

ROOM TEMP.SENSOR

58

WALL HOLE FOR REFRIGERANT PIPING


80 HOLE
55

TERMINAL BLOCK
(WITH EARTH TERMINAL)

UNDER

20

55

45

WIRELESS REMOTE CONTROLLER


ARC433B67
FLAP

46

45

50MIN
(SPACE FOR
MAINTENANCE)

STANDARD LOCATIONS OF WALL HOLES

3D050615A

SUPER MULTI NX E-Series Heat Pump

EDAU12-722

4.1.4

Dimensions

Floor Standing Type

FVXS25FV1A, FVXS35FV1A
700
666 (HALF CONCEALED)

TIMER LAMP

ROOM TEMP. THERMISTOR

SIGNAL RECEIVER

TERMINAL BLOCK
WITH EARTH TERMINAL

INDOOR UNIT ON/OFF SWITCH


210

O
F
O
N

GAS PIPE(9.5 CuT)

600

NAME PLATE

95.5

90

120.5

WIRELESS REMOTE CONTROLLER

44
38.5

115

UP/DOWN(AUTOMATIC)

RIGHT/LEFT(MANUAL)

COOL, DRY

UPPER AIR OUTLET

40

LOWER AIR OUTLET

UPWARD
AIR FLOW LIMIT
ON

45

45

90

90

585~595

(WALL HOLE)

90

UPWARD
AIR FLOW LIMIT
OFF

45

45

50MIN
(FOR
PERFORMANCE)

HEAT

670~690
(WALL HOLE)

20

70
(FOR PERFORMANCE)

HOLE
70
FOR PIPING

90

50MIN
(FOR
MAINTENANCE)

136
152

ADJUSTING THE AIR FLOW DIRECTION

38.5

O
F
O
N

ARC452A2

HOLE FOR SPLINT


HOLE FOR PIPING

121

20

AIR FLOW
REQUIRED SPACE

82

DRAIN HOSE
VP20
I. D. 20
O. D. 26
L 220

149
160

HOLE FOR PIPING

18

58

17

FIXED SCREWS FOR FRONT PANEL


630
FIXED SCREWS FOR MAIN UNIT

82

218.5
70

261

17

120.5
90

250

370
230

400

DRAIN
SOCKET

HOLE FOR SPLINT

SIGNAL TRANSMITTER

LIQUID PIPE(6.4 CuT)

AIR OUTLET
SELECTION
SWITCH
(INSIDE)

185.8

FIXED SCREWS FOR FRONT PANEL


(INSIDE)

584(HALF CONCEALED)

644
MAIN UNIT FIXING SCREW

OPERATION LAMP

25

NOTE) 1.THE MARK () SHOWS PIPING DIRECTION

3D056133
WALL HOLE FOR HALF CONCEALED

FVXS50FV1A
700
666 (HALF CONCEALED)

OPERATION LAMP

ROOM TEMP. THERMISTOR

INDOOR UNIT ON/OFF SWITCH


210
AIR OUTLET
SELECTION
SWITCH
(INSIDE)

FIXED SCREWS FOR FRONT PANEL


(INSIDE)
O
F
O
N

600

NAME PLATE

FIXED SCREWS FOR FRONT PANEL


630
FIXED SCREWS FOR MAIN UNIT

95.5

90

120.5

136
152

ARC452A2

WIRELESS REMOTE CONTROLLER

RIGHT/LEFT(MANUAL)

45

UPWARD
AIR FLOW LIMIT
OFF

LOWER AIR OUTLET

90

45

90

45

UPWARD
AIR FLOW LIMIT
ON

585~595
(WALL HOLE)

HEAT

90

45

WALL HOLE FOR HALF CONCEALED

UP/DOWN(AUTOMATIC)
COOL, DRY

UPPER AIR OUTLET

44
38.5

670~690
(WALL HOLE)

50MIN
(FOR
PERFORMANCE)

SUPER MULTI NX E-Series Heat Pump

HOLE FOR SPLINT


HOLE FOR PIPING

90

50MIN
(FOR
MAINTENANCE)

HOLE
70
FOR PIPING

70
(FOR PERFORMANCE)

O
F
O
N

VP20
I. D. 20
O. D. 26
L 220

ADJUSTING THE AIR FLOW DIRECTION


115

38.5

REQUIRED SPACE

82
121

40

AIR FLOW

18

20

HOLE FOR PIPING

58

17
DRAIN HOSE

149
160

82

218.5
70

261

17

120.5
90

230

250

370

400

DRAIN
SOCKET

HOLE FOR SPLINT

SIGNAL TRANSMITTER

LIQUID PIPE(6.4 CuT)


GAS PIPE(12.7 CuT)

25

644
MAIN UNIT FIXING SCREW

TERMINAL BLOCK
WITH EARTH TERMINAL

185.8

SIGNAL RECEIVER

584(HALF CONCEALED)

TIMER LAMP

20

NOTE) 1.THE MARK () SHOWS PIPING DIRECTION

3D056134

47

Dimensions

4.1.5

EDAU12-722

Ceiling Mounted Cassette Type (600600)

FFQ25B8V1B, FFQ35B8V1B with BYFQ60B7W1 (Decoration Panel)


300 OR LESS

700
NOTE)2.

585 ~ 660(CELING OPENING SPACE)


533(SUSPENTION POSITION)
320

89

PIPE CONNECTION
SIDE

CEILING
B
89

10

150

533 (SUSPENTION POSITION)

700

585 ~ 660(CELING OPENING SPACE)

210
DRAIN CONNECTION
SIDE

4-M4 HOLE

OUTDOOR AIR INTAKE


(DIRECT CONNECTION)
B ARROW VIEW

7
320
REQUIRED SPACE

62.5
575

62.5

575

1500mm
OR MORE

62.5

196

1500mm OR MORE

30

172
211

SUSPENTION BOLT
4-M8 ~ M10

45 OR LESS

45 OR LESS
NOTE)4.

A
NOTE) 1. STICKING LOCATION FOR MANUFACTURES LABEL
MANUFACTURES LABEL FOR INDOOR UNIT : ON THE BELL MOUTH INSIDE SUCTION GRILLE
MANUFACTURES LABEL FOR DECORATION PANEL : ON THE INNER FRAME INSIDE SUCTION GRILLE
2. IN CASE OF USING WIRELESS REMOTE CONTROLLER, THIS POSITION WILL BE A SIGNAL RECEIVER.
REFER TO THE DRAWING OF WIRELESS REMOTE CONTROLLER IN DETAIL.
3. WHEN THE TEMPERATURE AND HUMIDITY IN THE CEILING EXCEED 30C AND RH 80% OR THE FRESH AIR
IS INDUCTED INTO THE CEILING OR THE UNIT CONTINUES 24 HOUR OPERATION, AN ADDITIONAL
INSULATION (THICKNESS 10mm OR MORE OF GLASSWOOL OR POLYETHYLENE FORM) IS REQUIRED.
4. THOUGH THE INSTALLATION IS ACCEPTABLE UP TO MAXIMUM OF 660mm SQUARE CEILING OPENING,
KEEP THE CLEARANCE OF 45mm OR LESS BETWEEN THE MAIN UNIT AND THE CEILING OPENING SO THAT
THE PANEL OVERLAP ALLOWANCE CAN BE ENSURED.

DECORATION PANEL
BYFQ60B7W1

1500mm OR MORE
WHEN THE DISCHARGE GRILL IS CLOSEOUT,
THE REQUIRED SPACE IS 200mm OR MORE.

1500 OR MORE
(REQUIRED SPACE)
FROM THE FLOOR SIDE
2500 OR MORE
FOR HEIGHT INSTALLATION

(180)

145
183
285

25

205

260

55

1500mm OR MORE

62.5

295 OR MORE

750
ADJUSTABLE(0 ~ 545)

A ARROW VIEW

DRAIN HOSE (ACCESSORY)


SUCTION GRILLE
AIR DISCHARGE GRILL
REMOTE CONTROL CODE
AND CONTROL WIRING CONNECTION
4 POWER SUPPLY CONNECTION
3 DRAIN PIPE CONNECTION
2 GAS PIPE CONNECTION
1 LIQUID PIPE CONNECTION
PART NAME
ITEM
8
7
6
5

I. D.25 (OUTLET)

VP20(O.D.26)
9.5 (FLARE CONNECTION)
6.4 (FLARE CONNECTION)
REMARK

WHITE Ral 9010

C : 3D039003B

FFQ50B8V1B, FFQ60B8V1B with BYFQ60B7W1 (Decoration Panel)


585~660
(CELING OPENING SPACE)
300
OR LESS 533 (SUSPENTION POSITION)

NOTE) 2.

320
89
533(SUSPENTION POSITION)
585~660 (CELING OPENING SPACE)

8
DRAIN CONNECTION
SIDE

700

PIPE CONNECTION
SIDE

REQUIRED SPACE
1500mm OR MORE
3
62.5

575

62.5

62.5

62.5

575
196

1500 OR MORE
(REQUIRED SPACE) (180)
FROM THE FLOOR SIDE 295
2500 OR MORE
OR MORE

ADJUSTABLE(0545)

1500mm
OR MORE
1500mm OR
MORE

172
211

45 OR LESS
4

45 OR LESS
NOTE) 4.
A

DECORATION PANEL
BYFQ60B7W1 WHITE Ral 9010

1500mm OR MORE

WHEN THE DISCHARGE GRILL IS CLOSE OUT,


THE REQUIRED SPACE IS 200mm OR MORE.
FOR HEIGHT INSTALLATION

145
183
285

205

750
260
25

B ARROW VIEW

55
30

OUTDOOR AIR IN TAKE


(DIRECT CONNECTION)

320

NOTE)
1. STICKING LOCATION FOR MANUFACTURE'S LABEL
MANUFACTURE'S LABEL FOR INDOOR UNIT : ON THE BELL MOUTH INSIDE SUCTION GRILLE
MANUFACTURE'S LABEL FOR DECORATION PANEL : ON THE INNER FRAME INSIDE SUCTION GRILLE
2. IN CASE OF USING WIRELESS REMOTE CONTROLLER, THIS POSITION WILL BE A SIGNAL RECEIVER.
REFER TO THE DRAWING OF WIRELESS REMOTE CONTROLLER IN DETAIL.
3. WHEN THE TEMPERATURE AND HUMIDITY IN THE CEILING EXCEED 30C AND RH 80% OR THE FRESH AIR
IS INDUCTED INTO THE CEILING OR THE UNIT CONTINUES 24 HOUR OPERATION, AN ADDITIONAL
INSULATION (THICKNESS 10mm OR MORE OF GLASSWOOL OR POLYETHYLENE FORM) IS REQUIRED.
4. THOUGH THE INSTALLATION IS ACCEPTABLE UP TO MAXIMUM OF 660mm SQUARE CEILING OPENING,
KEEP THE CLEARANCE OF 45mm OR LESS BETWEEN THE MAIN UNIT AND THE CEILING OPENING SO THAT
THE PANEL OVERLAP ALLOWANCE CAN BE ENSURED.

48

4-M4 HOLE

100

A ARROW VIEW

SUSPENTION
BOLT
4-M8~M10

210
CEILING

150
89

700

DRAIN HOSE (ACCESSORY) I. D. 25 (OUTLET)


SUCTION GRILLE
AIR DISCHARGE GRILL
REMOTE CONTROL CODE
AND CONTROL WIRING
CONNECTION
4 POWER SUPPLY CONNECTION
3 DRAIN PIPE CONNECTION VP20 (O. D. 26)
2 GAS PIPE CONNECTION 12.7 (FLARE CONNECTION)
1 LIQUID PIPE CONNECTION 6.4 (FLARE CONNECTION)
REMARK
ITEM
PART NAME
8
7
6
5

C : 3D039005B

SUPER MULTI NX E-Series Heat Pump

EDAU12-722

Dimensions

BYFQ60B7W1 Decoration Panel (Option)

700

2
700

62.5

62.5

575

62.5

(140)
A

40
THICKNESS
OF PANEL SPACER

3
2

15
DIMENSION BETWEEN
THE BOTTOM SURFACE
OF INDOOR UNIT AND
THE SURFACE OF CEILING

105

575

143
245

62.5

255 OR MORE

A ARROW VIEW

3
2
1

PANEL SPACER
DECORATION PANEL
INDOOR UNIT

ITEM

NAME

REMARK

3D041038

BRC1C61 Wired Remote Controller (Option)


NOTE)1.REMOTE CONTROLLER CORD AND STAPLE ARE NOT ATTACHED.
THEY ARE FIELD SUPPLIED PARTS.
SPECIFICATIONS OF CORD
SHIELD WIRE
TYPE
(INSULATED THICKNESS : 1mm OR MORE)
SIZE
0.75~1.25mm 2
TOTAL
500m
LENGTH

38

84

120

42

REMOTE CONTROLLER DIMENSIONS

120

18

17

CORD OUTLET HOLE


23

28

46
INSTALLATION METHOD

STAPLE
REMOTE CONTROLLER

B EXPOSED BODY, EMBEDDED CORD


C EXPOSED BODY, EMBEDDED CORD
CONDUIT
17
REMOTE CONTROLLER
REMOTE CONTROLLER
117

A EXPOSED BODY, EXPOSED CORD

0~5
BETWEEN REMOTE
CONTROLLER AND
CONTROL BOX

(
17

SUPER MULTI NX E-Series Heat Pump

17

)
CONTROL BOX

THROUGH HOLE
(12~16)
C : 3D028952

49

Dimensions

EDAU12-722

BRC7E530W7 Wireless Remote Controller (Option for Heat Pump Type)


REMOTE CONTROLLER DIMENSIONS

RECEIVER INSTALLATION PROCEDURE

TRANSMITTING PART

157

DRAIN PIPING SIDE

REFRIGERANT PIPING SIDE

RECEIVER

62

17.5

REMOTE CONTROLLER HOLDER


INSTALLATION PROCEDURE
<INSTALLATION TO WALL SURFACE>
LIQUID CRYSTAL
REMOTE CONTROLLER
(WIRELESS)

RECEIVER DETAIL

DECORATION PANEL
(BYFQ60BW1)
(BYFQ60B7W1)
(BYFQ60B8W1)

REMOTE CONTROLLER
HOLDER

3D038937A

50

SUPER MULTI NX E-Series Heat Pump

EDAU12-722

4.2

Dimensions

Outdoor Units

3MXS52EVMA
MINIMUM SPACE FOR AIR PASSAGE

580

2
100

110
122

350

826

100

12

300 OR MORE

WALL HEIGHT ON AIR OUTLET SIDE = LESS THAN 1200

2-CUTS FOR ANCHOR BOLTS


(M8 OR M10)

501

50

2-12HOLE
(M8 OR M10)
DRAIN OUTLET
(I.D.15.9 HOSE FOR CONNECTION)

LIQUID
GAS

6.4
9.5
12.7

350

100

50

350

350

330
10

36

300
25

50

H<
=1200
H>1200

95
85
76

DIMENSION A
350
600

INSTALLATION SPACE FOR DISCHARGE SIDE(mm)

4-EARTH TERMINAL
ROOM A
GAS PIPE
(9.5 SINGLE
UNION)

LIQUID PIPE
(6.4SINGLE
UNION)

70

INTERCONNECTING PIPING
OUTDOOR AIR THERMISTOR
AND WIRING INLET

4-TERMINAL STRIP

ROOM B
GAS PIPE
(9.5 SINGLE
UNION)

70

NAME PLATE

LIQUID PIPE
(6.4 SINGLE
UNION)

12
C3
4

70 70

310
292

735

92

49

LIQUID STOP VALVE

ROOM C
GAS PIPE
(12.7 SINGLE
UNION)
LIQUID PIPE
(6.4 SINGLE
UNION)

285

164
8

255

30

GAS STOP VALVE

SERVICE PORT

3D051791A

3MXS68EVMA
MINIMUM SPACE FOR AIR PASSAGE

110
122

350

501

50

2-12HOLE
(M8 OR M10)
DRAIN OUTLET
(I.D. 15.9 HOSE FOR CONNECTION)

100

50

LIQUID
GAS

350

350

330
10

36

300
25

50

6.4
12.7

350

580

100

826

100

2-CUTS FOR ANCHOR BOLTS


(M8 OR M10)

12

300 OR MORE

WALL HEIGHT ON AIR OUTLET SIDE = LESS THAN 1200

H <
= 1200
H > 1200

95
76

DIMENSION A
350
600

INSTALLATION SPACE FOR DISCHARGE SIDE(mm)

4-EARTH TERMINAL

INTERCONNECTING PIPING OUTDOOR AIR THERMISTOR


AND WIRING INLET

ROOM A
GAS PIPE
(12.7 SINGLE
UNION)

ROOM B
GAS PIPE
(12.7 SINGLE
UNION)
LIQUID PIPE
(6.4 SINGLE
UNION)

70 70

310
292

735

92

SERVICE PORT

49

285

164
8

255

LIQUID STOP VALVE

30

LIQUID PIPE
(6.4 SINGLE
UNION)

70

4-TERMINAL STRIP

70

NAME PLATE

ROOM C
GAS PIPE
(12.7 SINGLE
UNION)
LIQUID PIPE
(6.4 SINGLE
UNION)

GAS STOP VALVE

3D054642

SUPER MULTI NX E-Series Heat Pump

51

Dimensions

EDAU12-722

4MXS80EVMA
MINIMUM SPACE FOR AIR PASSAGE
900
4-CUTS FOR ANCHOR BOLTS
(M12)

WALL HEIGHT ON AIR OUTLET SIDE = LESS THAN 1200

191

350

100

380

100

350

376

50

30

320
350
(345~355)

102 71
117
30

45

50

350

140

100

620

DRAIN OUTLET
I. D. 25 HOSE FOR CONNECTION.

NAME PLATE

50
GAS STOP VALVE
5-TERMINAL STRIP
WITH EARTH TERMINAL
LIQUID STOP VALVE

OUTDOOR AIR
THERMISTOR

104
6.4
9.5
12.7
15.9

52

108
91
83
78

INTERCONNECTING PIPING
AND WIRING INLET

30

126

90 76 76 76

76 76 76

770

ROOM A
GAS PIPE
(9.5 SINGLE UNION)
LIQUID PIPE
(6.4 SINGLE UNION)

37

ROOM B
GAS PIPE
(12.7 SINGLE UNION)
LIQUID PIPE
(6.4 SINGLE UNION)
ROOM C
GAS PIPE
(15.9 SINGLE UNION)
LIQUID PIPE
(6.4 SINGLE UNION)
ROOM D
GAS PIPE
(15.9 SINGLE UNION)
LIQUID PIPE
(6.4 SINGLE UNION)

3D052078A

SUPER MULTI NX E-Series Heat Pump

EDAU12-722

Wiring Diagrams

5. Wiring Diagrams
5.1

Indoor Units

5.1.1

Wall Mounted Type

FTXS20DVMA, FTXS25EVMA, FTXS35EVMA

2
FIELD WIRING.

S27

PCB3

S26

PCB1

F1U

~
RECTIFIER

LED1

H1

3.15A

X1M

V1

H1P

H2

LED2
H2P
LED3
H3P

WHT

RED

GRN /

H3

TRANSMISSION
CIRCUIT

BLK

FG

S1
RED

t
HA

R1T

BLU
BRN
ORG

INTELLIGENT EYE
SENSOR

WHT

S35
S28

PCB2

S32

S6

M
M1F

FG
F1U
H1P~H3P
M1F
M1S
PCB1~PCB4
R1T, R2T
S1~S38
S1W
X1M

RED
ORG
YLW
PNK
BLU

S36

PCB4

OUTDOOR

CAUTION
NOTE THAT OPERATION WILL
RESTART AUTOMATICALLY IF
THE MAIN POWER SUPPLY IS
TURNED OFF AND THEN BACK
ON AGAIN.

YLW

S1W
S21

:
:
:
:
:
:
:
:
:
:
:

FRAME GROUND
FUSE
PILOT LAMP
FAN MOTOR
SWING MOTOR
PRINTED CIRCUIT BOARD
THERMISTOR.
CONNECTOR
OPERATION SWITCH
TERMINAL STRIP
PROTECTIVE EARTH

S29
R2T

WIRELESS
REMOTE
CONTROLLER

SIGNAL
RECEIVER

INDOOR

M
M1S

3D046453B

FTXS50FVMA, FTXS60FVMA, FTXS71FVMA

FIELD WIRING.
PCB3

S27

S26

PCB1

H1

~
~
RECTIFIER

Fu
3.15A
H2

t
R1T
S38

BLK

WHT

RED 3
GRN
/
YLW

H3

TRANSMISSION
CIRCUIT

X1M

FG
PCB4
S37

S21

S1
RED

LED1 LED2 LED3


H1P

BLU
BRN
ORG
WHT

H2P H3P

PCB5

S36

S35

INTELLIGENT EYE

S28

S32

S6

S8

M
M1F

SIGNAL
WIRELESS
REMOTE

t
S29

INDOOR

R2T

RECEIVER
S1W

CONTROLLER

SUPER MULTI NX E-Series Heat Pump

BRN
RED
ORG
YLW
PNK
BLU

PCB2

RED
ORG
YLW
PNK
BLU

SENSOR

M
M1S

M
M2S

FG
Fu
H1 ~ H3
H1P ~ H3P
M1F
M1S, M2S
PCB1~ PCB5
R1T, R2T
S1 ~ S38
S1W
X1M

OUTDOOR

CAUTION
NOTE THAT OPERATION WILL
RESTART AUTOMATICALLY IF
THE MAIN POWER SUPPLY IS
TURNED OFF AND THEN BACK
ON AGAIN.
: FRAME GROUND
: FUSE
: HARNESS
: PILOT LAMP
: FAN MOTOR
: SWING MOTOR
: PRINTED CIRCUIT BOARD
: THERMISTOR
: CONNECTOR
: OPERATION SWITCH
: TERMINAL STRIP
: PROTECTIVE EARTH
3D038530N

53

Wiring Diagrams

5.1.2

EDAU12-722

Duct Connected Type

FDXS25CVMA, FDXS35CVMA, FDXS50CVMA, FDXS60CVMA, CDXS25EAVMA, CDXS35EAVMA

X1M

PCB1
PCB2

BLK

WHT

RED

H1
F1U
3.15A

V1TR
LED LED LED S1
1
H1P H2P H3P

S26
1

(
SIGNAL

10
2 RTH11

2 S32 1

GRY

YLW
C1

BRN BRN
M
1~

PPL

Q1M
130C

indoor
BLU

R2T
WIRELESS
REMOTE
CONTROLLER

:
C1 :
F1U :

CAUTION
NOTE THAT OPERATION WILL
RESTART AUTOMATICALLY IF
THE MAIN POWER SUPPLY IS
TURNED OFF AND THEN BACK
ON AGAIN.

TRANSMISSION
GND
CIRCUIT

FIELD WIRING.

GRN / YLW

BLK

RED

S7

10

R1T

GRN / YLW

S1

WHT
t

N=2

H3
6

S21

S1W

RECEIVER

outdoor

Z1C
H2

TERMINAL FOR
CENTRALIZED CONTROL

1
2
3

M1F

PROTECTIVE EARTH
CAPACITOR(M1F)
FUSE

H1P ~ H3P
M1F
PCB1 ~ PCB2
Q1M
R1T ~ R2T
S1 ~ S32, RTH1
S1W
V1TR
X1M
Z1C

: PILOT LAMP
: FAN MOTOR
: PRINTED CIRCUIT BOARD
: THERMAL PROTECTOR (M1F EMBEDDED)
: THERMISTOR
: CONNECTOR
: OPERATION SWITCH
: PHASE CONTROL CIRCUIT
: TERMINAL BLOCK
: NOISE FILTER(FERRITE CORE)

3D045012K

5.1.3

Floor / Ceiling Suspended Dual Type

FLXS25BVMA, FLXS35BVMA, FLXS50BVMA, FLXS60BVMA

PCB3

S25

PCB1

S24

S37

PCB2

S36

LED LED LED

H1
Fu
3.15A

H1P H2P H3P

H2

PCB4

C70

S1W
SIGNAL
RECEIVER

TRANSMISSION
CIRCUIT

HA
S27

S26

S7

S21

S31

S32

R1T

R2T

H5

X1M
1
2
3

1
2
3

outdoor

FIELD WIRING.

CAUTION

H6

NOTE THAT OPERATION WILL


RESTART AUTOMATICALLY IF
THE MAIN POWER SUPPLY IS
TURNED OFF AND THEN BACK
ON AGAIN.

indoor

S6

X11A
X21A

M
WIRELESS
REMOTE
CONTROLLER

H4

H3

BLK
WHT
RED
GRN/
YLW

M1S

1~
t
100C

M1F

: PROTECTIVE EARTH
C70
: RUNNING CAPACITOR
FU
: FUSE
H1P~H3P : PILOT LAMP
M1F
: FAN MOTOR
M1S
: SWING MOTOR

PCB1~PCB4
R1T~R2T
S6~S37, X11A, X21A
S1W
X1M

: PRINTED CIRCUIT BOARD


: THERMISTOR
: CONNECTOR
: OPERATION SWITCH(SW7)
: TERMINAL STRIP

3D033909E

54

SUPER MULTI NX E-Series Heat Pump

EDAU12-722

5.1.4

Wiring Diagrams

Floor Standing Type

FVXS25FV1A, FVXS35FV1A, FVXS50FV1A

2
PCB3
S27

S2W(4)

PCB2
S26

V1 F1U

~
~
RECTIFIER

H1
H2

S4W
WIRELESS
REMOTE
CONTROLLER

TRANSMISSION
CIRCUIT
PCB4

H1P

S1W

S47

E1

H2P
1

M1S

M2S

RED
ORG
YLW
PNK
BLU
RED
ORG
YLW
PNK
BLU

S42
1

S21

GRN

S1

E3

RED
BLU
BRN
ORG
WHT

HA
S48

S49

PCB1
S32

indoor

CAUTION
NOTE THAT OPERATION WILL
RESTART AUTOMATICALLY IF
THE MAIN POWER SUPPLY IS
TURNED OFF AND THEN BACK
ON AGAIN.

M1F

R1T
6
S41
1

outdoor

FIELD WIRING.

E3

E4

V2

S46

LED2

GRN
GRN/YLW

H3
SA1

SIGNAL
RECEIVER
LED1

BLK
WHT
RED

3.15A

1
2
3

X1M
1
2
3

t
R2T

F1U
H1P,H2P
M1F
M1S
M2S
PCB1~PCB4
R1T,R2T
S1~S49
S1W
S2W(4)
S4W
X1M
E3
E4

: PROTECTIVE EARTH
: FUSE
: PILOT LAMP
: FAN MOTOR
: SWING MOTOR
: LOWER AIR OUTLET MOTOR
: PRINTED CIRCUIT BOARD
: THERMISTOR
: CONNECTOR
: OPERATION SWITCH
: UPWARD AIR FLOW LIMIT SWITCH
: AIR OUTLET SELECTION SWITCH
: TERMINAL STRIP
: EARTH TERMINAL(HEAT EX.)
: EARTH TERMINAL(SHIELD PLATE)

3D055953

SUPER MULTI NX E-Series Heat Pump

55

Wiring Diagrams

5.1.5

EDAU12-722

Ceiling Mounted Cassette Type

NOTES)
1.
: TERMINAL
: FIELD WIRING

R2T

t
YLW
WHT

A1P

YLW

X19A

X18A

X61A
X10A
X60A

T1R
t

GRN
NOTE)5

X24A
NOTE)3

X17A

F2
F1
P2
P1
X5A X1M

X11A

KPR
V1TR

X20A

NE
WIRED
REMOTE
CONTROLLER
SS1
P2
P1 R1T

C1

RED
X25A
RC

TC

X40A
,

: CONNECTER DISCRIMINATION COLOUR FOR COMPONENTS.


: CONNECTER COLOUR FOR COMPONENTS.
: CONNECTER COLOUR FOR PRINTED CIRCUIT BOARD.

R3T

WHT

IN CASE OF SIMULTANEOUS
OPERATION SYSTEM
INDOOR UNIT INDOOR UNIT
(MASTER)
(SLAVE)
TO OUTDOOR X2M
F1U
1 BLK
UNIT
1
1
2 WHT
2
2
3
3
3
RED
GRN/YLW X27A
X2M
X2M
H05VV-U4G2.5
REMOTE
A4P
A1P A3P
CONTROLLER
SS1
H1P
H2P BS1
SS2
H3P
X24A
X2A
H4P
NOTE)3
X1A
X1A
RECEIVER/DISPLAY UNIT

R1T

YLW

TO OUTDOOR UNIT

FFQ25B8V1B, FFQ35B8V1B, FFQ50B8V1B, FFQ60B8V1B

: CONNECTOR

2. IN CASE USING CENTRAL REMOTE CONTROLLER, CONNECT IT TO THE UNIT


IN ACCORDANCE WITH THE ATTACHED INSTALLATION MANUAL.
3. X24A IS CONNECTED WHEN THE WIRELESS REMOTE CONTROLLER KIT IS
BEING USED.
4. REMOTE CONTROLLER MODEL VARIES ACCORDING TO THE COMBINATION
SYSTEM, CONFIRM ENGINEERING MATERIALS AND CATALOGS, ETC. BEFORE CONNECTING.
5. GROUND THE SHIELD OF THE REMOTE CONTROLLER CORD TO THE INDOOR UNIT(IN CASE OF USING SHIELD WIRE).
6. SYMBOLS SHOW AS FOLLOWS: RED: RED BLK: BLACK WHT: WHITE YLW: YELLOW PRP: PURPLE GRY: GRAY BLU: BLUE

YLW
YLW

M
~

BLK

M
~
M1P

MSW

X36A
X33A

X35A

Q1M

M1F

M1S
HAP

X15A
S1L

C1
T1R
X1M

A1P

X2M

CONTROL BOX
A1P
C1
F1U
HAP

PRINTED CIRCUIT BOARD


CAPACITOR(M1F)
FUSE(F5A 250V)
LIGHT EMITTING DIODE
(SERVICE MONITOR GREEN)
KPR MAGNETIC RELAY(M1P)
M1F MOTOR(INDOOR FAN)
M1P MOTOR(DRAIN PUMP)
M1S MOTOR(SWING FLAP)
Q1M THERMO SWITCH(M1F EMBEDDED)
R1T THERMISTOR(AIR)
R2T THERMISTOR(COIL-1)
R3T THERMISTOR(COIL-2)
S1L FLOAT SWITCH
T1R TRANSFORMER(220-240V/22V)
V1TR PHASE CONTROL CIRCUIT
X1M TERMINAL STRIP
X2M TERMINAL STRIP
RC
SIGNAL RECEIVER CIRCUIT
SIGNAL TRANSMISSION CIRCUIT
TC
WIRED REMOTE CONTROLLER
R1T THERMISTOR(AIR)
SS1 SELECTOR SWITCH(MAIN/SUB)
WIRELESS REMOTE CONTROLLER
(RECEIVER/DISPLAY UNIT)
A3P PRINTED CIRCUIT BOARD
A4P PRINTED CIRCUIT BOARD

56

PUSH BUTTON(ON/OFF)
LIGHT EMITTING DIODE
(ON-RED)
H2P LIGHT EMITTING DIODE
(TIMER-GREEN)
H3P LIGHT EMITTING DIODE
(FILTER SIGN-RED)
H4P LIGHT EMITTING DIODE
(DEFROST-ORANGE)
SS1 SELECTOR SWITCH
(MAIN/SUB)
SS2 SELECTOR SWITCH
(WIRELESS ADDRESS SET)
CONNECTOR FOR OPTIONAL PARTS
X33A CONNECTOR
(ADAPTOR FOR WIRING)
X35A CONNECTOR
(GROUP CONTROL ADAPTOR)
X40A CONNECTOR
(ON/OFF INPUT FROM OUTSIDE)
X60A CONNECTOR
X61A (INTERFACE ADAPTOR
FOR SKYAIR SERIES)
BS1
H1P

3D038357B

SUPER MULTI NX E-Series Heat Pump

EDAU12-722

5.2

Wiring Diagrams

Outdoor Units

3MXS52EVMA
L1R

SW5

YLW

M
3~

BLU

SW1

SW3

Y1E

Y2E

R3T R2T R1T


R8T R9T R10T
(OUTDOOR) (DISCHARGE) (ROOM-A) (ROOM-C)
(CONDENSER)
(ROOM-B)
<GASPIPE>

Y3E

SW4

YLW

S93

1
GRY

BLU

BLK

BRN

S92

1
GRY

WHT
YLW
ORG
BLU
BRN
RED

1 S90 6

BLK

C
1 S22 6

BLK

B
1 S21 6

GRN

BLK
BLK

MRC W
3 S80 1

A
1 S20 6

Y1R

BLU

12 1 S102 5
S52
PCB2
LED
S2
4 3 2 1 A
SW2

RED

YLW
BLU

S40
V5

RED

FIELD WIRING

RED

PCB1
WHT

SHEET METAL

indoor

M1C

X11A

U
V
W

5
4
3

WHT
YLW
ORG
BLU
BRN
RED

BLK

PM1

WHT
YLW
ORG
BLU
BRN
RED

WHT

BLU
BLU
BLU
BLU
BLU
BLU
BLU
BLU
BLU
BLU
BLU
BLU

12 1 S101 5
RED
BLK
WHT

S51

BLU
BRN
ORG
WHT

S70
1

+ + +

M1F
M

Q1L

7
1
3 S15
5

X4M
1
2
3

RED

V3

WHT

BLK

S10

BLU C

6(P)

FU2
3.15A

BLU

7(N)
2

YLW B

BLK

V11

BLU

RED

X3M
1
2
3

ROOM C
1
2
3

WHT

X2M
1
2
3

ROOM A
1
2
3

MRM10
V6

AC2

3.15A

BLK

AC1

FU3

MRM20

BRN

Z3C
TO INDOOR UNIT
ROOM B
1
2
3

SA2
FU1
30A V2

BLK

Z2C

L
N

E2

E1

HR2

HR1

GRN

WHT

Z1C

X1M
POWER SUPPLY

WHT

GRN
GRN
YLW

R4T R5T R6T


(ROOM-A) (ROOM-C)
(ROOM-B)
<LIQUIDPIPE>

outdoor
Z1C ~ Z3C
: FERRITE CORE
X1M ~ X4M
: TERMINAL STRIP
Y1E ~ Y3E
: ELECTRONIC EXPANSION VALVE COIL
V2, V3, V5, V6, V11 : VARISTOR
SA2
: SURGE ARRESTER
FU1, FU2, FU3
: FUSE
AC1, AC2
U, V, W, X11A
E1, E2
HR1, HR2
: CONNECTOR

L
: LIVE
N
: NEUTRAL
SW1 : FORCED OPERATION ON/OFF SW (SW1)
SW2 : SELECT SW (SW2)
SW3 : WIRING ERROR CHECK SW (SW3)
SW4 : PRIORITY ROOM SETTING SW (SW4)
SW5 : NIGHT QUIET MODE SETTING SW (SW5)

MRM10, MRM20
: MAGNETIC RELAY
MRC/W
R1T ~ R6T
: THERMISTOR
R8T ~ R10T
: CONNECTOR
S2 ~ S102
LED1 ~ LED4
: PILOT LAMP
LEDA

M1C
: COMPRESSOR MOTOR
M1F
: FAN MOTOR
L1R
: REACTOR
Q1L
: OVERLOAD PROTECTOR
PM1
: POWER MODULE
PCB1, 2
: PRINTED CIRCUIT BOARD
Y1R
: REVERSING SORENOID VALVE COIL
SHEETMETAL : TERMINAL STRIP FIXED PLATE

3D051012B

3MXS68EVMA

SHEET METAL

S15
1
MRC W

A
S20 6

B
1 S21 6

C
1 S22 6
WHT
YLW
ORG
BLU
BRN
RED

S71

RED
BRN

M1C
X11A
U
RED
V
YLW 3M N
BLU
W
BRN

S34

Q1L

10

YLW

BLU

8 1

BLK
BLK

YLW

GRY

BLU

8 1
1

1
4
S40

10

S33

S6
1 S90 6

S92

outdoor

S52
PCB2

12 1 S102 5

LED-4 LED-3 LED-2 LED-1 LED-A


SW2 SW5 SW1 SW3

Y1R

Y1E

S2

Y2E

Y3E

SW4

Z1C~Z3C
: FERRITE CORE
X1M~X4M
: TERMINAL STRIP
Y1E~Y3E
: ELECTRONIC EXPANSION VALVE COIL
V2~V5
: VARISTOR
FU1, FU2, FU201 : FUSE
HE2 , HL , HN
E, AC1, AC2
H1, H2, L1
L2, HAC1
: CONNECTOR
MRM10, MRM20
MRB, MRD
MRC/W
: MAGNETIC RELAY

SUPER MULTI NX E-Series Heat Pump

R1T~R12T
S2~S102
LED-A, LED-1~4
L
N
SW1
SW2
SW3
SW4
SW5
SA1
Y1R

: THERMISTOR
: CONNECTOR
: PILOT LAMP
: LIVE
: NEUTRAL
: FORCED OPERATION ON/OFF SW
: FORCED OPERATION MODE SELECT SW
: WIRING ERROR CHECK SW
: PRIORITY ROOM SETTING SW
: NIGHT QUIET MODE SETTING SW
: SURGE ARRESTER
: REVERSING SOLENOID VALVE COIL

S93

BLK
BLK
GRY
GRY
YLW
YLW

BLK
BLK
GRY
GRY
BRN
BRN

BLU
BLU
GRY
GRY
BLK
BLK

BLU

BLU

BLU
BLU
BLU
BLU
BLU
BLU
BLU
BLU
BLU
BLU
BLU
BLU

indoor

FIELD WIRING

S80

WHT
YLW
ORG
BLU
BRN
RED

12 1S1015

M
1

S31
1

WHT
YLW
ORG
BLU
BRN
RED

S51

MRD

MRB

S72

10

S32
3

W
V
U
N

RED

CN14

M1F

BLU
BRN
ORG
WHT

TB6
TB5
TB4

BLK
BLK
BLK
BLK
BLK
BLK
BLK
BLK
BLK

S91

+ + +

N1
P2

W
V
U

SPM

5
BLK
BLK
BLK
BLK
BLK

BLK
BLK

X2M
1
2
3

BLK

PCB1

V5
7

WHT

ROOM A
1
2
3

~-

R12T

FU2
3.15A

YLW

RED

P1

L2 P1
N1
P2

L1

CN11
1

S10
1

BLU

BLK

X3M
1
2
3

DB1
+

ORG

RED

3.15A
S70

WHT

ROOM B
1
2
3

WHT

X4M
1
2
3

BLU

V2
RED

Z2C
YLW

CT1
H2

AC2
BLU

Z3C
TO INDOOR UNIT
ROOM C
1
2
3

H1

L
N

GRN

POWER SUPPLY
L
N

MRM10

BRN

BLK
BLK

BRN

ORG

MRM20

E
AC1

30A

X1M

MID2

Z1C

RED

SA1
PCB3 V3
HL FU1 HAC1

FU201 7

L1R

HE2

WHT
ORG
BRN
BLU

YLW

BRN

GRN
YLW

GRN

RED
BLK
WHT

GRN
YLW

R3T R2T R1T


R8T R9T R10T
R4T R5T R6T
(OUTDOOR)(DISCHARGE) (ROOM-A)(ROOM-C) (ROOM-A)(ROOM-C)
(CONDENSER)
(ROOM-B)
(ROOM-B)
(GAS PIPE)
(LIQUID PIPE)

DB1
M1C
M1F
L1R
Q1L
CT1
PCB1~PCB3
MID1~MID2
SPM

: DIODE BRIDGE
: COMPRESSOR MOTOR
: FAN MOTOR
: REACTOR
: OVERLOAD PROTECTOR
: CURRENT TRANSFORMER
: PRINTED CIRCUIT BOARD
: MOLDED INTER CONNECT DEVICE
: SYSTEM POWER MODULE

3D054538

57

Wiring Diagrams

EDAU12-722

4MXS80EVMA

L1R
Z1C

X1M

FIELD WIRING

U
V
W

X11A
RED
V
YLW
BLU

RED
YLW
BLU

Z4C

M1C
U
M
3~
W

Q1L
BLK
BLK

V5

S40

: FERRITE CORE
: TERMINAL STRIP
: ELECTRONIC EXPANSION VALVE COIL
: VARISTOR
: SURGE ARRESTER
: FUSE

MRM10, MRM20
MRC/W
R1T~R3T
R4T~R7T
R8T~R11T
S2~S102
LED1~LED5
LEDA

: MAGNETIC RELAY
: THERMISTOR
: CONNECTOR
: PILOT LAMP

L
N
SW1
SW2
SW3
SW4
SW5

R8T R9T R10T R11T

<GAS PIPE>

: LIVE
: NEUTRAL
: FORCED OPERATION ON/OFF SW(SW1)
: SELECT SW(SW2)
: WIRING ERROR CHECK SW(SW3)
: PRIORITY ROOM SETTING SW(SW4)
: NIGHT QUIET MODE SETTING SW(SW5)

M1C
M1F
L1R
Q1L
PM1
PCB1, 2
Y1R
SHEET METAL

YLW

BLU

RED
t

GRY

BRN

BLK

GRY

11

R4T R5T R6T R7T


(ROOM-D)

R3T R2T R1T

(ROOM-C)

SW4

S93

(ROOM-B)

M
Y4E

10

(ROOM-D)

M
Y3E

S92

(ROOM-C)

M
Y2E

1 S90 6

BLK

WHT
YLW
ORG
BLU
BRN
RED

WHT
YLW
ORG
BLU
BRN
RED

M
Y1E

(ROOM-B)

Y1R

WHT
YLW
ORG
BLU
BRN
RED

WHT
YLW
ORG
BLU
BRN
RED

BLK

WHT
YLW
RED
BLU
A
B
C
D
6 4 S80 1 1 S20 6 1 S21 6 1 S22 6 1 S23 6

(ROOM-A)

12 1 S102 5
S52
LED PCB2 S2
4 3 2 1 A

SW2 SW5 SW1 SW3

outdoor

1
S70

5
4
3

BLK

MRC W
1 S101 5

Z1C~Z6C
X1M~X5M
Y1E~Y4E
V2, V3, V5, V9, V100
SA2
FU1, FU2, FU3
AC1, AC2
U, V, W, X11A
E1, E2
HR1, HR2

+ + +

PM1

(OUTDOOR)

SHEET METAL

indoor

12

M1F
M

BLU
BRN
ORG
WHT

PCB1

BLK

1
3 S15
5
S51
1

6(P)

V3

S10

RED
BLK
WHT
GRN

X5M
1
2
3

WHT

BLK

ROOM D
1
2
3

WHT

BLK
BLK

X4M
1
2
3

FU2
3.15A

BLK

ROOM C
1
2
3

A
B
YLW
C
BLU
D
ORG
RED

X3M
1
2
3

BLU

WHT

ROOM A
1
2
3

X2M
1
2
3

7(N)

V9

AC2

WHT

TO INDOOR UNIT
ROOM B
1
2
3

Z5C
RED

3.15A
V100

MRM10

(DISCHARGE)

BRN

Z3C

FU3 7

HR2

HR1

MRM20

(CONDENSER)

E2

GRY

Z2C

E1

SA2
FU1
AC1 30A V2

BLU

BLU
BLU
BLU
BLU
BLU
BLU
BLU
BLU
BLU
BLU
BLU
BLU

POWER SUPPLY
L
N

BLU

WHT

Z6C

(ROOM-A)

GRN
GRN
YLW

<LIQUID PIPE>
: COMPRESSOR MOTOR
: FAN MOTOR
: REACTOR
: OVERLOAD PROTECTOR
: POWER MODULE
: PRINTED CIRCUIT BOARD
: FOUR WAY VALVE COIL
: TERMINAL STRIP FIXED PLATE

: CONNECTOR

3D051963A

58

SUPER MULTI NX E-Series Heat Pump

EDAU12-722

Piping Diagrams

6. Piping Diagrams
6.1

Indoor Units

6.1.1

Wall Mounted Type

FTXS20DVMA, FTXS25EVMA, FTXS35EVMA

FTXS50FVMA, FTXS60FVMA

2
INDOOR UNIT

INDOOR UNIT
MAFFLER ASSY
HEAT EXCHANGER
7.0CuT

(7.9CuT)

7.9CuT

6.4CuT

FIELD PIPING
(6.4CuT)

HEAT EXCHANGER

THERMISTOR
ON HEAT EXCH.

6.4CuT
6.4CuT

THERMISTOR
ON HEAT EXCH.
FIELD PIPING
(6.4CuT)

CROSS FLOW FAN

FIELD PIPING
(12.7CuT)

FAN MOTOR

CROSS FLOW FAN

M
FAN MOTOR
(12.7CuT)

9.5CuT

FIELD PIPING
(9.5CuT)

REFRIGERANT FLOW
COOLING
HEATING
REFRIGERANT FLOW
COOLING
HEATING

4D047912F

4D040081Q

FTXS71FVMA

INDOOR UNIT

(7.9CuT)

HEAT EXCHANGER

THERMISTOR
ON HEAT EXCH.
FIELD PIPING
(6.4CuT)
FIELD PIPING
(15.9CuT)

CROSS FLOW FAN

M
FAN MOTOR
(12.7CuT)

REFRIGERANT FLOW
COOLING
HEATING

4D040082P

SUPER MULTI NX E-Series Heat Pump

59

Piping Diagrams

6.1.2

EDAU12-722

Duct Connected Type

FDXS25CVMA, FDXS35CVMA, FDXS50CVMA, FDXS60CVMA, CDXS25EAVMA, CDXS35EAVMA


INDOOR UNIT
(6.4CuT)

HEAT EXCHANGER

FIELD PIPING
(6.4CuT)

THERMISTOR
ON HEAT
EXCH.

SIROCCO FAN

M
FAN MOTOR
FIELD PIPING
(
CuT)

CDXS25CVMB
CDKS25CVMB
CDXS35CVMB
CDKS35CVMB
CDXS25CVMA
CDXS35CVMA
FDXS25CVMB
FDXS35CVMB
FDXS35CVMA
FDXS25EAVMB
FDXS35EAVMB
FDKS25CVMB
FDKS35CVMB
FDKS25EAVMB
FDKS35EAVMB
CDKS25CVMA
CDKS35CVMA
CDXS25DVMT
CDXS35DVMT
CDKS25DVMT
CDKS35DVMT
FDXS25CAVMB
FDXS35CAVMB
FDKS25CAVMB
FDKS35CAVMB
CDXS25EAVMA
CDXS35EAVMA
CDKS25EAVMA
CDKS35EAVMA
CDXS25EAVMT
CDXS35EAVMT
CDKS25EAVMT
CDKS35EAVMT
CDXS25EV2C
CDXS35EV2C
FDXS25CVMA

6.1.3

9.5

CDXS50CVMB
CDKS50CVMB
CDXS60CVMB
CDKS60CVMB
CDXS50CVMA
CDXS60CVMA
CDKS50CVMA
CDKS60CVMA
CDXS50DVMT
CDXS60DVMT
CDKS50DVMT
CDKS60DVMT
FDXS50CVMB
FDXS60CVMB
FDKS50CVMB
FDKS60CVMB
CDXS50EV2C
CDXS60EV2C
FDXS50CVMA
FDXS60CVMA

CuT)

REFRIGERANT FLOW
COOLING
HEATING

12.7

4D045449J

Floor / Ceiling Suspended Dual Type

FLXS25BVMA, FLXS35BVMA

FLXS50BVMA, FLXS60BVMA

INDOOR UNIT

INDOOR UNIT

(9.5CuT)

(6.4CuT)

HEAT EXCHANGER

HEAT EXCHANGER

FIELD PIPING
(6.4CuT)

SIROCCO FAN

THERMISTOR
ON HEAT
EXCH.

FIELD PIPING
(6.4CuT)

FAN MOTOR

FAN MOTOR
FIELD PIPING
(9.5CuT)

(9.5CuT)

FIELD PIPING
(12.7CuT)

(12.7CuT)

REFRIGERANT FLOW
COOLING
HEATING

REFRIGERANT FLOW
COOLING
HEATING

4D048722A

60

SIROCCO FAN

THERMISTOR
ON HEAT
EXCH.

4D048724A

SUPER MULTI NX E-Series Heat Pump

EDAU12-722

6.1.4

Piping Diagrams

Floor Standing Type

FVXS25FV1A, FVXS35FV1A

2
INDOOR UNIT
MUFFLER ASSY
7.0CuT

6.4CuT

HEAT EXCHANGER

6.4CuT

6.4CuT

THERMISTOR
ON HEAT EXCH.

6.4CuT

TURBO FAN FAN MOTOR

FIELD PIPING
(6.4CuT)

6.4CuT

9.5CuT

FIELD PIPING
(9.5CuT)

REFRIGERANT FLOW
COOLING
HEATING

4D056137

FVXS50FV1A

INDOOR UNIT
MUFFLER ASSY
7.0CuT

6.4CuT
6.4CuT

HEAT EXCHANGER

6.4CuT

6.4CuT

THERMISTOR
ON HEAT EXCH.

M
FIELD PIPING
(6.4CuT)

TURBO FAN FAN MOTOR

FIELD PIPING
(12.7CuT)

9.5CuT

6.4CuT
6.4CuT
6.4CuT

REFRIGERANT FLOW
COOLING
HEATING

4D056138

SUPER MULTI NX E-Series Heat Pump

61

Piping Diagrams

6.1.5

EDAU12-722

Ceiling Mounted Cassette Type

FFQ25B8V1B, FFQ35B8V1B, FFQ50B8V1B, FFQ60B8V1B

Indoor heat exchanger

MODEL

FFQ25 35B8V1B

6.4

9.5

FFQ50 60B8V1B

6.4

12.7

Field piping

C1220T-O

Field piping

C1220T-O

To
Outdoor unit

Indoor unit
C : 4D039335

62

SUPER MULTI NX E-Series Heat Pump

EDAU12-722

6.2

Piping Diagrams

Outdoor Units

3MXS52EVMA

OUTDOOR UNIT

HEAT EXCHANGER OUTDOOR TEMPERATURE


THERMISTOR(DOA)

HEADER

9.5CuT

HEADER

ELECTRONIC
EXPANSION VALVE LIQUID PIPE
THERMISTOR(DLA)
EVA
6.4CuT
FILTER
ELECTRONIC
EXPANSION VALVE LIQUID PIPE
THERMISTOR(DLB)
EVB
6.4CuT

FILTER

HEAT EXCHANGER
THERMISTOR(DE)

DISTRIBUTOR
CAPILLARY TUBE

LIQUID LINE
STOP VALVE

DC FAN MOTOR M

FILTER
ELECTRONIC
EXPANSION VALVE LIQUID PIPE
THERMISTOR(DLC)
EVC
6.4CuT
FILTER

ROOM A
(6.4 CuT)

ROOM B
(6.4 CuT)

FIELD
PIPING
LIQUID
SIDE

ROOM C
(6.4 CuT)

PROPELLER FAN

12.7CuT

12.7CuT
12.7CuT

HEADER
REVERSING
SOLENOID
VALVE

12.7CuT
MUFFLER

MUFFLER

12.7CuT

7.9CuT

DISCHARGE PIPE
THERMISTOR(DO)

MUFFLER
GAS LINE
STOP VALVE

REFRIGERANT FLOW
COOLING
HEATING

12.7CuT

GAS PIPE THERMISTOR(DGA)


ROOM A
(9.5 CuT)
GAS PIPE THERMISTOR(DGB)
ROOM B
(9.5 CuT)
GAS PIPE THERMISTOR(DGC)

FIELD
PIPING
GAS
SIDE

ROOM C
(12.7 CuT)

ACCUMULATOR

COMPRESSOR

3D052055B

3MXS68EVMA

OUTDOOR UNIT
HEAT EXCHANGER OUTDOOR TEMPERATURE
THERMISTOR(DOA)

HEADER

9.5CuT

HEADER

ELECTRONIC
EXPANSION VALVE LIQUID PIPE
THERMISTOR(DLA)
EVA
6.4CuT
FILTER
ELECTRONIC
EXPANSION VALVE LIQUID PIPE
THERMISTOR(DLB)
EVB
6.4CuT

FILTER

HEAT EXCHANGER
THERMISTOR(DE)

DISTRIBUTOR
CAPILLARY TUBE

DC FAN MOTOR

LIQUID LINE
STOP VALVE

FILTER
ELECTRONIC
EXPANSION VALVE LIQUID PIPE
THERMISTOR(DLC)
EVC
6.4CuT
FILTER

ROOM A
(6.4 CuT)

ROOM B
(6.4 CuT)

FIELD
PIPING
LIQUID
SIDE

ROOM C
(6.4 CuT)

PROPELLER FAN

12.7CuT

12.7CuT

12.7CuT
REVERSING
SOLENOID
VALVE
7.9CuT

MUFFLER
DISCHARGE PIPE
THERMISTOR(DO)

REFRIGERANT FLOW
COOLING COMPRESSOR
HEATING

HEADER
12.7CuT

12.7CuT

12.7CuT

GAS LINE
STOP VALVE
ACCUMULATOR

12.7CuT

GAS PIPE THERMISTOR(DGA)


ROOM A
(12.7 CuT)
GAS PIPE THERMISTOR(DGB)
ROOM B
(12.7 CuT)
GAS PIPE THERMISTOR(DGC)

FIELD
PIPING
GAS
SIDE

ROOM C
(12.7 CuT)

ACCUMULATOR

3D054639

SUPER MULTI NX E-Series Heat Pump

63

Piping Diagrams

EDAU12-722

4MXS80EVMA

OUTDOOR UNIT
HEAT EXCHANGER
7.9CuT
7.9CuT
7.9CuT
7.9CuT
7.9CuT
7.9CuT
7.9CuT
7.9CuT

RECEIVER

HEADER

HEAT EXCHANGER
(CONDENSER)
THERMISTOR
7.9CuT

DC FAN MOTOR

9.5CuT

9.5CuT

9.5CuT

12.7CuT

HEADER

OUTDOOR
TEMPERATURE
THERMISTOR

MOTOR OPERATED
VALVE (E)

DISTRIBUTOR

LIQUID LINE
STOP VALVE

CAPILLARY TUBE

MOTOR OPERATED LIQUID PIPE


VALVE (A)
THERMISTOR
EVA
(ROOM-A)
7.9CuT
MOTOR OPERATED LIQUID PIPE FILTER
VALVE (B)
THERMISTOR
EVB
(ROOM-B)
7.9CuT
MOTOR OPERATED LIQUID PIPE FILTER
VALVE (C)
THERMISTOR
(ROOM-C)
EVC
7.9CuT
MOTOR OPERATED LIQUID PIPE FILTER
VALVE (D)
THERMISTOR
EVD
(ROOM-D)
7.9CuT
FILTER

ROOM A
(6.4 CuT)
ROOM B
(6.4 CuT)
ROOM C
(6.4 CuT)

FIELD
PIPING
LIQUID

ROOM D
(6.4 CuT)

PROPELLER FAN
4-WAY
VALVE

15.9CuT

9.5CuT
15.9CuT

FILTER

HEADER

7.9CuT

12.7CuT

REFRIGERANT FLOW
COOLING COMPRESSOR
HEATING

ACCUMULATOR ACCUMULATOR

15.9CuT

7.9CuT

15.9CuT

15.9CuT

7.9CuT
MUFFLER
DISCHARGE PIPE
THERMISTOR

12.7CuT

12.7CuT
12.7CuT

GAS LINE
STOP VALVE
MUFFLER MUFFLER
15.9CuT 12.7CuT

GAS PIPE THERMISTOR


(ROOM-A)
GAS PIPE THERMISTOR
(ROOM-B)
GAS PIPE THERMISTOR
(ROOM-C)
GAS PIPE THERMISTOR
(ROOM-D)

ROOM A
(9.5 CuT)
ROOM B
(12.7 CuT)
ROOM C
(15.9 CuT)

FIELD
PIPING
GAS

ROOM D
(15.9 CuT)

15.9CuT

3D051937B

64

SUPER MULTI NX E-Series Heat Pump

EDAU12-722

Capacity Tables

7. Capacity Tables
7.1

Total Capacity

7.1.1

3MXS52EVMA

[Cooling Capacity 50Hz 230V]


Combination
(Capacity)
2.0

2.5

3.5

5.0

2.0+2.0

2.0+2.5

2.0+3.5

2.0+5.0

Outdoor
air temp.
CDB
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0

SUPER MULTI NX E-Series Heat Pump

14C
TC
PI
kW
kW
2.63
0.55
2.63
0.59
2.59
0.69
2.51
0.71
2.38
0.76
2.30
0.79
2.22
0.82
2.63
0.55
2.63
0.59
2.63
0.64
2.63
0.69
2.63
0.78
2.63
0.85
2.53
0.88
3.00
0.69
3.00
0.74
3.00
0.87
3.00
0.94
3.00
1.07
3.00
1.17
3.00
1.27
5.32
1.48
5.32
1.60
5.29
1.95
5.13
2.02
4.86
2.15
4.70
2.23
4.36
2.07
5.26
1.27
5.26
1.37
5.26
1.67
5.26
1.83
5.00
1.95
4.83
2.03
4.63
2.07
5.26
1.27
5.26
1.37
5.26
1.67
5.26
1.83
5.22
2.19
5.05
2.27
4.63
2.07
5.63
1.46
5.63
1.58
5.63
1.94
5.52
2.06
5.23
2.19
5.06
2.27
4.64
2.07
6.95
1.70
6.76
1.76
6.31
1.92
6.11
1.99
5.79
2.12
5.60
2.20
5.16
2.07

16C
TC
PI
kW
kW
2.99
0.62
2.91
0.64
2.72
0.70
2.64
0.72
2.51
0.77
2.43
0.80
2.35
0.83
3.23
0.63
3.23
0.67
3.11
0.75
3.02
0.78
2.87
0.83
2.77
0.86
2.68
0.89
3.68
0.87
3.68
0.94
3.68
1.11
3.68
1.20
3.68
1.37
3.68
1.50
3.68
1.64
6.10
1.76
5.94
1.82
5.56
1.98
5.40
2.05
5.13
2.18
4.97
2.26
4.58
2.07
6.27
1.60
6.10
1.66
5.71
1.80
5.55
1.87
5.27
1.98
5.10
2.06
4.86
2.07
6.46
1.75
6.38
1.86
5.97
2.02
5.80
2.09
5.51
2.22
5.34
2.31
4.86
2.07
6.56
1.79
6.39
1.86
5.98
2.02
5.81
2.09
5.52
2.22
5.34
2.31
4.87
2.07
7.27
1.73
7.08
1.80
6.63
1.95
6.43
2.02
6.11
2.15
5.92
2.23
5.42
2.07

Indoor air temp.:CWB


18C
19C
TC
PI
TC
PI
kW
kW
kW
kW
3.12
0.63
3.18
0.64
3.04
0.65
3.10
0.66
2.85
0.71
2.92
0.72
2.77
0.73
2.84
0.74
2.64
0.78
2.71
0.79
2.56
0.81
2.63
0.82
2.48
0.84
2.55
0.85
3.56
0.68
3.63
0.69
3.47
0.71
3.54
0.71
3.26
0.77
3.33
0.77
3.17
0.79
3.24
0.80
3.01
0.84
3.09
0.85
2.92
0.87
3.00
0.88
2.83
0.91
2.91
0.91
4.42
1.08
4.81
1.20
4.42
1.16
4.81
1.29
4.42
1.39
4.65
1.46
4.42
1.50
4.52
1.51
4.21
1.59
4.31
1.60
4.08
1.65
4.18
1.66
3.95
1.71
4.06
1.72
6.37
1.79
6.50
1.81
6.21
1.86
6.34
1.87
5.83
2.01
5.96
2.03
5.67
2.09
5.80
2.10
5.40
2.21
5.53
2.23
5.23
2.30
5.37
2.31
4.79
2.07
4.90
2.07
6.54
1.63
6.68
1.65
6.38
1.69
6.52
1.70
5.99
1.83
6.13
1.85
5.82
1.90
5.96
1.91
5.55
2.01
5.68
2.03
5.38
2.09
5.52
2.10
5.10
2.07
5.21
2.07
6.84
1.83
6.98
1.84
6.67
1.89
6.81
1.91
6.26
2.05
6.40
2.07
6.09
2.13
6.23
2.14
5.80
2.26
5.94
2.27
5.62
2.34
5.77
2.36
5.09
2.07
5.20
2.07
6.85
1.83
7.00
1.84
6.68
1.89
6.82
1.91
6.27
2.05
6.41
2.07
6.10
2.13
6.24
2.14
5.81
2.26
5.95
2.27
5.63
2.34
5.78
2.36
5.09
2.07
5.20
2.07
7.59
1.77
7.75
1.78
7.39
1.83
7.55
1.85
6.94
1.98
7.10
2.00
6.75
2.06
6.91
2.07
6.43
2.18
6.59
2.20
6.24
2.26
6.40
2.28
5.67
2.07
5.79
2.07

2
22C
TC
PI
kW
kW
3.38
0.66
3.30
0.68
3.12
0.73
3.04
0.76
2.90
0.80
2.82
0.83
2.75
0.86
3.86
0.71
3.77
0.73
3.55
0.79
3.46
0.82
3.31
0.87
3.22
0.90
3.13
0.93
5.38
1.34
5.25
1.38
4.96
1.50
4.83
1.55
4.62
1.64
4.50
1.70
4.37
1.76
6.90
1.86
6.74
1.92
6.36
2.08
6.20
2.15
5.93
2.28
5.77
2.36
5.21
2.07
7.09
1.69
6.93
1.75
6.54
1.89
6.37
1.96
6.09
2.08
5.93
2.15
5.55
2.07
7.41
1.90
7.24
1.96
6.83
2.12
6.66
2.19
6.37
2.33
6.20
2.41
5.52
2.07
7.43
1.90
7.25
1.96
6.85
2.12
6.67
2.19
6.38
2.33
6.21
2.41
5.53
2.07
8.22
1.83
8.03
1.89
7.58
2.05
7.39
2.12
7.07
2.25
6.87
2.33
6.15
2.07

24C
TC
PI
kW
kW
3.51
0.67
3.43
0.69
3.25
0.74
3.17
0.77
3.03
0.82
2.96
0.84
2.88
0.87
4.01
0.72
3.91
0.75
3.70
0.81
3.61
0.83
3.46
0.88
3.37
0.91
3.28
0.95
5.59
1.36
5.46
1.41
5.17
1.52
5.04
1.57
4.83
1.66
4.70
1.72
4.58
1.78
7.17
1.89
7.01
1.96
6.63
2.11
6.47
2.19
6.20
2.32
6.04
2.40
5.41
2.07
7.37
1.72
7.20
1.78
6.81
1.92
6.65
1.99
6.37
2.11
6.20
2.18
5.76
2.07
7.70
1.93
7.53
1.99
7.12
2.15
6.95
2.23
6.66
2.36
6.48
2.44
5.73
2.07
7.71
1.93
7.54
1.99
7.13
2.15
6.96
2.23
6.67
2.36
6.49
2.44
5.74
2.07
8.54
1.87
8.35
1.93
7.90
2.08
7.71
2.15
7.38
2.28
7.19
2.36
6.38
2.07

65

Capacity Tables

Combination
(Capacity)
2.5+2.5

2.5+3.5

2.5+5.0

3.5+3.5

3.5+5.0

2.0+2.0+2.0

2.0+2.0+2.5

2.0+2.0+3.5

2.0+2.5+2.5

66

EDAU12-722

Outdoor
air temp.
CDB
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0

14C
TC
PI
kW
kW
5.26
1.32
5.26
1.42
5.26
1.72
5.26
1.89
5.22
2.19
5.05
2.27
4.63
2.07
5.63
1.49
5.63
1.61
5.63
1.97
5.62
2.16
5.32
2.30
5.15
2.39
4.65
2.07
6.95
1.70
6.76
1.76
6.31
1.92
6.11
1.99
5.79
2.12
5.60
2.20
5.16
2.07
6.00
1.64
6.00
1.78
5.84
2.08
5.66
2.16
5.36
2.30
5.19
2.39
4.69
2.07
6.96
1.71
6.77
1.77
6.32
1.93
6.12
2.00
5.80
2.13
5.61
2.21
5.16
2.07
7.08
1.78
6.88
1.84
6.43
2.00
6.23
2.08
5.90
2.21
5.70
2.29
5.17
2.07
7.08
1.78
6.88
1.84
6.43
2.00
6.23
2.08
5.90
2.21
5.70
2.29
5.17
2.07
7.10
1.78
6.90
1.84
6.44
2.00
6.25
2.08
5.92
2.21
5.72
2.29
5.18
2.07
7.08
1.78
6.88
1.84
6.43
2.00
6.23
2.08
5.90
2.21
5.70
2.29
5.17
2.07

16C
TC
PI
kW
kW
6.46
1.75
6.38
1.86
5.97
2.02
5.80
2.09
5.51
2.22
5.34
2.31
4.86
2.07
6.68
1.89
6.50
1.95
6.09
2.12
5.91
2.20
5.62
2.34
5.44
2.42
4.88
2.07
7.27
1.73
7.08
1.80
6.63
1.95
6.43
2.02
6.11
2.15
5.92
2.23
5.42
2.07
6.73
1.89
6.55
1.95
6.14
2.12
5.96
2.20
5.66
2.34
5.48
2.42
4.91
2.07
7.28
1.74
7.09
1.80
6.64
1.96
6.44
2.03
6.12
2.16
5.93
2.24
5.42
2.07
7.41
1.81
7.21
1.87
6.75
2.04
6.55
2.11
6.23
2.24
6.03
2.33
5.42
2.07
7.41
1.81
7.21
1.87
6.75
2.04
6.55
2.11
6.23
2.24
6.03
2.33
5.42
2.07
7.43
1.81
7.23
1.87
6.77
2.04
6.57
2.11
6.24
2.24
6.05
2.33
5.44
2.07
7.41
1.81
7.21
1.87
6.75
2.04
6.55
2.11
6.23
2.24
6.03
2.33
5.42
2.07

Indoor air temp.:CWB


18C
19C
TC
PI
TC
PI
kW
kW
kW
kW
6.84
1.83
6.98
1.84
6.67
1.89
6.81
1.91
6.26
2.05
6.40
2.07
6.09
2.13
6.23
2.14
5.80
2.26
5.94
2.27
5.62
2.34
5.77
2.36
5.09
2.07
5.20
2.07
6.97
1.92
7.12
1.94
6.80
1.99
6.94
2.01
6.38
2.16
6.53
2.17
6.20
2.23
6.35
2.25
5.91
2.37
6.05
2.39
5.73
2.46
5.88
2.48
5.10
2.07
5.21
2.07
7.59
1.77
7.75
1.78
7.39
1.83
7.55
1.85
6.94
1.98
7.10
2.00
6.75
2.06
6.91
2.07
6.43
2.18
6.59
2.20
6.24
2.26
6.40
2.28
5.67
2.07
5.79
2.07
7.03
1.92
7.17
1.94
6.85
1.99
7.00
2.01
6.43
2.16
6.58
2.17
6.25
2.23
6.40
2.25
5.95
2.37
6.10
2.39
5.78
2.46
5.92
2.48
5.13
2.07
5.24
2.07
7.60
1.78
7.76
1.79
7.41
1.84
7.56
1.85
6.95
1.99
7.11
2.01
6.76
2.07
6.92
2.08
6.44
2.19
6.60
2.21
6.25
2.27
6.40
2.29
5.67
2.07
5.79
2.07
7.73
1.84
7.89
1.86
7.53
1.91
7.70
1.93
7.07
2.07
7.24
2.09
6.88
2.15
7.04
2.16
6.55
2.28
6.71
2.29
6.35
2.36
6.52
2.38
5.67
2.07
5.79
2.07
7.73
1.84
7.89
1.86
7.53
1.91
7.70
1.93
7.07
2.07
7.24
2.09
6.88
2.15
7.04
2.16
6.55
2.28
6.71
2.29
6.35
2.36
6.52
2.38
5.67
2.07
5.79
2.07
7.75
1.84
7.91
1.86
7.55
1.91
7.72
1.93
7.09
2.07
7.26
2.09
6.90
2.15
7.06
2.16
6.57
2.28
6.73
2.29
6.37
2.36
6.53
2.38
5.68
2.07
5.81
2.07
7.73
1.84
7.89
1.86
7.53
1.91
7.70
1.93
7.07
2.07
7.24
2.09
6.88
2.15
7.04
2.16
6.55
2.28
6.71
2.29
6.35
2.36
6.52
2.38
5.67
2.07
5.79
2.07

22C
TC
PI
kW
kW
7.41
1.90
7.24
1.96
6.83
2.12
6.66
2.19
6.37
2.33
6.20
2.41
5.52
2.07
7.56
1.99
7.38
2.06
6.97
2.23
6.79
2.31
6.49
2.44
6.32
2.53
5.53
2.07
8.22
1.83
8.03
1.89
7.58
2.05
7.39
2.12
7.07
2.25
6.87
2.33
6.15
2.07
7.62
1.99
7.44
2.06
7.02
2.23
6.84
2.31
6.54
2.44
6.37
2.53
5.56
2.07
8.24
1.84
8.04
1.90
7.59
2.06
7.40
2.13
7.08
2.26
6.88
2.34
6.15
2.07
8.38
1.91
8.18
1.98
7.72
2.14
7.53
2.21
7.20
2.35
7.00
2.43
6.14
2.07
8.38
1.91
8.18
1.98
7.72
2.14
7.53
2.21
7.20
2.35
7.00
2.43
6.14
2.07
8.40
1.91
8.21
1.98
7.75
2.14
7.55
2.21
7.22
2.35
7.02
2.43
6.16
2.07
8.38
1.91
8.18
1.98
7.72
2.14
7.53
2.21
7.20
2.35
7.00
2.43
6.14
2.07

24C
TC
PI
kW
kW
7.70
1.93
7.53
1.99
7.12
2.15
6.95
2.23
6.66
2.36
6.48
2.44
5.73
2.07
7.85
2.03
7.67
2.10
7.26
2.26
7.08
2.34
6.79
2.48
6.61
2.57
5.73
2.07
8.54
1.87
8.35
1.93
7.90
2.08
7.71
2.15
7.38
2.28
7.19
2.36
6.38
2.07
7.91
2.03
7.73
2.10
7.32
2.26
7.14
2.34
6.84
2.48
6.66
2.57
5.77
2.07
8.55
1.88
8.36
1.94
7.91
2.09
7.72
2.17
7.39
2.29
7.20
2.37
6.38
2.07
8.70
1.95
8.51
2.01
8.05
2.17
7.85
2.25
7.52
2.38
7.33
2.47
6.37
2.07
8.70
1.95
8.51
2.01
8.05
2.17
7.85
2.25
7.52
2.38
7.33
2.47
6.37
2.07
8.73
1.95
8.53
2.01
8.07
2.17
7.87
2.25
7.54
2.38
7.35
2.47
6.39
2.07
8.70
1.95
8.51
2.01
8.05
2.17
7.85
2.25
7.52
2.38
7.33
2.47
6.37
2.07

SUPER MULTI NX E-Series Heat Pump

EDAU12-722

Combination
(Capacity)
2.0+2.5+3.5

2.0+3.5+3.5

2.5+2.5+2.5

2.5+2.5+3.5

2.0+2.0+5.0

Capacity Tables

Outdoor
air temp.
CDB
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0

Symbols

14C
TC
PI
kW
kW
7.10
1.78
6.90
1.84
6.44
2.00
6.25
2.08
5.92
2.21
5.72
2.29
5.18
2.07
7.11
1.78
6.91
1.84
6.45
2.00
6.26
2.08
5.93
2.21
5.73
2.29
5.19
2.07
7.08
1.78
6.88
1.84
6.43
2.00
6.23
2.08
5.90
2.21
5.70
2.29
5.17
2.07
7.10
1.78
6.90
1.84
6.44
2.00
6.25
2.08
5.92
2.21
5.72
2.29
5.18
2.07
7.34
1.80
7.14
1.86
6.66
2.03
6.46
2.10
6.12
2.24
5.92
2.32
5.32
2.07

16C
TC
PI
kW
kW
7.43
1.81
7.23
1.87
6.77
2.04
6.57
2.11
6.24
2.24
6.05
2.33
5.44
2.07
7.44
1.81
7.24
1.87
6.78
2.04
6.58
2.11
6.25
2.24
6.05
2.33
5.44
2.07
7.41
1.81
7.21
1.87
6.75
2.04
6.55
2.11
6.23
2.24
6.03
2.33
5.42
2.07
7.43
1.81
7.23
1.87
6.77
2.04
6.57
2.11
6.24
2.24
6.05
2.33
5.44
2.07
7.68
1.83
7.48
1.90
7.00
2.06
6.80
2.14
6.46
2.27
6.25
2.36
5.58
2.07

Indoor air temp.:CWB


18C
19C
TC
PI
TC
PI
kW
kW
kW
kW
7.75
1.84
7.91
1.86
7.55
1.91
7.72
1.93
7.09
2.07
7.26
2.09
6.90
2.15
7.06
2.16
6.57
2.28
6.73
2.29
6.37
2.36
6.53
2.38
5.68
2.07
5.81
2.07
7.76
1.84
7.93
1.86
7.57
1.91
7.73
1.93
7.10
2.07
7.27
2.09
6.91
2.15
7.07
2.16
6.58
2.28
6.74
2.29
6.38
2.36
6.54
2.38
5.69
2.07
5.81
2.07
7.73
1.84
7.89
1.86
7.53
1.91
7.70
1.93
7.07
2.07
7.24
2.09
6.88
2.15
7.04
2.16
6.55
2.28
6.71
2.29
6.35
2.36
6.52
2.38
5.67
2.07
5.79
2.07
7.75
1.84
7.91
1.86
7.55
1.91
7.72
1.93
7.09
2.07
7.26
2.09
6.90
2.15
7.06
2.16
6.57
2.28
6.73
2.29
6.37
2.36
6.53
2.38
5.68
2.07
5.81
2.07
8.02
1.87
8.18
1.89
7.81
1.93
7.98
1.95
7.34
2.10
7.50
2.12
7.13
2.17
7.30
2.19
6.79
2.31
6.96
2.33
6.59
2.39
6.76
2.41
5.83
2.07
5.95
2.07

22C
TC
PI
kW
kW
8.40
1.91
8.21
1.98
7.75
2.14
7.55
2.21
7.22
2.35
7.02
2.43
6.16
2.07
8.41
1.91
8.22
1.98
7.76
2.14
7.56
2.21
7.23
2.35
7.03
2.43
6.17
2.07
8.38
1.91
8.18
1.98
7.72
2.14
7.53
2.21
7.20
2.35
7.00
2.43
6.14
2.07
8.40
1.91
8.21
1.98
7.75
2.14
7.55
2.21
7.22
2.35
7.02
2.43
6.16
2.07
8.69
1.94
8.48
2.00
8.01
2.17
7.80
2.24
7.46
2.38
7.26
2.46
6.32
2.07

24C
TC
PI
kW
kW
8.73
1.95
8.53
2.01
8.07
2.17
7.87
2.25
7.54
2.38
7.35
2.47
6.39
2.07
8.74
1.95
8.54
2.01
8.08
2.17
7.88
2.25
7.56
2.38
7.36
2.47
6.40
2.07
8.70
1.95
8.51
2.01
8.05
2.17
7.85
2.25
7.52
2.38
7.33
2.47
6.37
2.07
8.73
1.95
8.53
2.01
8.07
2.17
7.87
2.25
7.54
2.38
7.35
2.47
6.39
2.07
9.02
1.97
8.82
2.04
8.34
2.20
8.14
2.28
7.80
2.41
7.60
2.50
6.55
2.07

NOTE:

TC

: Total capacity

(kW)

PI

: Power input

(kW)

Capacities are based on the following conditions.


Corresponding refrigerant piping length : 7.5m
Level difference : 0m
3D055052
3D055053

SUPER MULTI NX E-Series Heat Pump

67

Capacity Tables

EDAU12-722

[Heating Capacity 50Hz 230V]


Combination
(Capacity)
2.0

2.5

3.5

5.0

2.0+2.0

2.0+2.5

2.0+3.5

2.0+5.0

2.5+2.5

2.5+3.5

2.5+5.0

68

Indoor
air temp.
CDB
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0

-15C
TC
PI
kW
kW
2.08 0.97
2.02 0.98
1.97 0.99
1.95 1.00
1.92 1.00
1.87 1.01
2.21 1.02
2.16 1.03
2.10 1.04
2.08 1.05
2.05 1.05
1.99 1.06
2.67 1.36
2.60 1.37
2.53 1.39
2.50 1.40
2.47 1.40
2.40 1.42
3.76 2.03
3.66 2.05
3.57 2.08
3.52 2.09
3.48 2.10
3.38 2.12
3.87 1.84
3.78 1.87
3.68 1.89
3.63 1.90
3.58 1.91
3.49 1.93
3.87 1.84
3.78 1.87
3.68 1.89
3.63 1.90
3.58 1.91
3.49 1.93
3.90 1.84
3.80 1.87
3.70 1.89
3.65 1.90
3.60 1.91
3.51 1.93
4.40 1.80
4.29 1.82
4.18 1.84
4.12 1.85
4.07 1.86
3.96 1.88
3.87 1.87
3.78 1.89
3.68 1.91
3.63 1.92
3.58 1.93
3.49 1.95
3.98 1.91
3.88 1.93
3.78 1.95
3.73 1.96
3.68 1.97
3.58 1.99
4.40 1.80
4.29 1.82
4.18 1.84
4.12 1.85
4.07 1.86
3.96 1.88

-10C
TC
PI
kW
kW
2.50 1.02
2.45 1.03
2.39 1.04
2.37 1.05
2.34 1.05
2.29 1.06
2.67 1.07
2.61 1.08
2.55 1.09
2.53 1.10
2.50 1.11
2.44 1.12
3.21 1.43
3.14 1.44
3.08 1.46
3.05 1.47
3.01 1.47
2.95 1.49
4.52 2.13
4.43 2.16
4.34 2.18
4.29 2.19
4.24 2.20
4.15 2.22
4.66 1.94
4.57 1.96
4.47 1.98
4.42 1.99
4.37 2.00
4.28 2.02
4.66 1.94
4.57 1.96
4.47 1.98
4.42 1.99
4.37 2.00
4.28 2.02
4.69 1.94
4.59 1.96
4.50 1.98
4.45 1.99
4.40 2.00
4.30 2.02
5.30 1.89
5.19 1.91
5.08 1.93
5.02 1.94
4.97 1.95
4.86 1.97
4.66 1.96
4.57 1.98
4.47 2.01
4.42 2.02
4.37 2.03
4.28 2.05
4.79 2.01
4.69 2.03
4.59 2.05
4.54 2.06
4.49 2.07
4.39 2.09
5.30 1.89
5.19 1.91
5.08 1.93
5.02 1.94
4.97 1.95
4.86 1.97

Outdoor air temp.:CWB


-5C
0C
6C
TC
PI
TC
PI
TC
PI
kW
kW
kW
kW
kW
kW
2.92 1.07 3.35 1.12 3.85 1.18
2.87 1.08 3.29 1.13 3.80 1.19
2.82 1.09 3.24 1.14 3.75 1.20
2.79 1.10 3.22 1.15 3.72 1.21
2.77 1.10 3.19 1.15 3.70 1.21
2.71 1.11 3.14 1.16 3.65 1.22
3.12 1.12 3.57 1.18 4.11 1.24
3.06 1.13 3.51 1.19 4.06 1.25
3.01 1.15 3.46 1.20 4.00 1.26
2.98 1.15 3.43 1.20 3.97 1.27
2.95 1.16 3.40 1.21 3.94 1.27
2.90 1.17 3.35 1.22 3.89 1.28
3.76 1.50 4.30 1.57 4.95 1.65
3.69 1.51 4.23 1.58 4.89 1.66
3.62 1.53 4.17 1.60 4.82 1.68
3.59 1.54 4.13 1.60 4.79 1.69
3.56 1.54 4.10 1.61 4.75 1.70
3.49 1.56 4.03 1.63 4.69 1.71
5.29 2.24 6.06 2.34 6.98 2.46
5.20 2.26 5.96 2.36 6.88 2.49
5.10 2.28 5.87 2.39 6.79 2.51
5.06 2.29 5.82 2.40 6.74 2.52
5.01 2.31 5.78 2.41 6.70 2.53
4.92 2.33 5.68 2.43 6.60 2.56
5.45 2.03 6.24 2.13 7.19 2.24
5.36 2.05 6.15 2.15 7.10 2.26
5.26 2.07 6.05 2.17 7.00 2.28
5.21 2.08 6.00 2.18 6.95 2.29
5.16 2.09 5.95 2.19 6.90 2.30
5.07 2.11 5.86 2.21 6.81 2.32
5.45 2.03 6.24 2.13 7.19 2.24
5.36 2.05 6.15 2.15 7.10 2.26
5.26 2.07 6.05 2.17 7.00 2.28
5.21 2.08 6.00 2.18 6.95 2.29
5.16 2.09 5.95 2.19 6.90 2.30
5.07 2.11 5.86 2.21 6.81 2.32
5.49 2.03 6.28 2.13 7.23 2.24
5.39 2.05 6.18 2.15 7.14 2.26
5.29 2.07 6.09 2.17 7.04 2.28
5.24 2.08 6.04 2.18 6.99 2.29
5.19 2.09 5.99 2.19 6.94 2.30
5.10 2.11 5.89 2.21 6.85 2.32
6.19 1.98 7.09 2.07 8.17 2.18
6.08 2.00 6.98 2.09 8.06 2.20
5.98 2.02 6.87 2.11 7.95 2.22
5.92 2.03 6.82 2.12 7.90 2.23
5.87 2.04 6.76 2.13 7.84 2.24
5.76 2.06 6.65 2.15 7.73 2.26
5.45 2.06 6.24 2.15 7.19 2.27
5.36 2.08 6.15 2.18 7.10 2.29
5.26 2.10 6.05 2.20 7.00 2.31
5.21 2.11 6.00 2.21 6.95 2.32
5.16 2.12 5.95 2.22 6.90 2.33
5.07 2.14 5.86 2.24 6.81 2.35
5.60 2.10 6.41 2.20 7.39 2.32
5.50 2.12 6.32 2.22 7.29 2.34
5.40 2.15 6.22 2.24 7.19 2.36
5.35 2.16 6.17 2.25 7.14 2.37
5.30 2.17 6.12 2.26 7.09 2.38
5.21 2.19 6.02 2.29 6.99 2.40
6.19 1.98 7.09 2.07 8.17 2.18
6.08 2.00 6.98 2.09 8.06 2.20
5.98 2.02 6.87 2.11 7.95 2.22
5.92 2.03 6.82 2.12 7.90 2.23
5.87 2.04 6.76 2.13 7.84 2.24
5.76 2.06 6.65 2.15 7.73 2.26

10C
TC
PI
kW
kW
4.19 1.22
4.14 1.23
4.09 1.24
4.06 1.24
4.04 1.25
3.99 1.26
4.47 1.28
4.42 1.29
4.36 1.30
4.33 1.31
4.31 1.31
4.25 1.32
5.39 1.71
5.32 1.72
5.26 1.74
5.22 1.74
5.19 1.75
5.12 1.77
7.59 2.55
7.50 2.57
7.40 2.59
7.36 2.60
7.31 2.62
7.22 2.64
7.83 2.31
7.73 2.33
7.63 2.36
7.58 2.37
7.54 2.38
7.44 2.40
7.83 2.31
7.73 2.33
7.63 2.36
7.58 2.37
7.54 2.38
7.44 2.40
7.87 2.31
7.77 2.33
7.68 2.36
7.63 2.37
7.58 2.38
7.48 2.40
8.89 2.25
8.78 2.27
8.67 2.29
8.61 2.30
8.56 2.31
8.45 2.33
7.83 2.34
7.73 2.37
7.63 2.39
7.58 2.40
7.54 2.41
7.44 2.43
8.04 2.40
7.94 2.42
7.84 2.44
7.79 2.45
7.74 2.46
7.64 2.48
8.89 2.25
8.78 2.27
8.67 2.29
8.61 2.30
8.56 2.31
8.45 2.33

15C
TC
PI
kW
kW
4.62 1.27
4.56 1.28
4.51 1.29
4.49 1.29
4.46 1.30
4.41 1.31
4.92 1.33
4.87 1.34
4.81 1.35
4.79 1.36
4.76 1.36
4.70 1.38
5.93 1.77
5.87 1.79
5.80 1.80
5.77 1.81
5.73 1.82
5.67 1.83
8.36 2.65
8.26 2.67
8.17 2.70
8.12 2.71
8.08 2.72
7.98 2.74
8.62 2.41
8.52 2.43
8.42 2.45
8.37 2.46
8.33 2.47
8.23 2.49
8.62 2.41
8.52 2.43
8.42 2.45
8.37 2.46
8.33 2.47
8.23 2.49
8.67 2.41
8.57 2.43
8.47 2.45
8.42 2.46
8.37 2.47
8.28 2.49
9.79 2.34
9.68 2.36
9.57 2.38
9.51 2.39
9.46 2.40
9.35 2.42
8.62 2.44
8.52 2.46
8.42 2.48
8.37 2.49
8.33 2.50
8.23 2.52
8.85 2.49
8.75 2.51
8.65 2.53
8.60 2.55
8.55 2.56
8.45 2.58
9.79 2.34
9.68 2.36
9.57 2.38
9.51 2.39
9.46 2.40
9.35 2.42

SUPER MULTI NX E-Series Heat Pump

EDAU12-722

Combination
(Capacity)
3.5+3.5

3.5+5.0

2.0+2.0+2.0

2.0+2.0+2.5

2.0+2.0+3.5

2.0+2.5+2.5

2.0+2.5+3.5

2.0+3.5+3.5

2.5+2.5+2.5

2.5+2.5+3.5

Capacity Tables

Indoor
air temp.
CDB
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0

SUPER MULTI NX E-Series Heat Pump

-15C
TC
PI
kW
kW
4.00 1.90
3.90 1.92
3.80 1.94
3.75 1.95
3.70 1.96
3.60 1.99
4.42 1.79
4.31 1.81
4.20 1.83
4.14 1.84
4.09 1.85
3.98 1.87
4.44 1.73
4.33 1.75
4.22 1.77
4.16 1.78
4.11 1.79
3.99 1.81
4.44 1.73
4.33 1.75
4.22 1.77
4.16 1.78
4.11 1.79
3.99 1.81
4.45 1.73
4.34 1.75
4.23 1.77
4.18 1.78
4.12 1.79
4.01 1.81
4.44 1.73
4.33 1.75
4.22 1.77
4.16 1.78
4.11 1.79
3.99 1.81
4.45 1.73
4.34 1.75
4.23 1.77
4.18 1.78
4.12 1.79
4.01 1.81
4.47 1.73
4.36 1.75
4.25 1.77
4.19 1.78
4.14 1.79
4.02 1.81
4.44 1.73
4.33 1.75
4.22 1.77
4.16 1.78
4.11 1.79
3.99 1.81
4.45 1.73
4.34 1.75
4.23 1.77
4.18 1.78
4.12 1.79
4.01 1.81

-10C
TC
PI
kW
kW
4.81 2.00
4.71 2.02
4.61 2.04
4.56 2.05
4.51 2.06
4.41 2.08
5.32 1.88
5.21 1.90
5.10 1.92
5.04 1.93
4.99 1.94
4.88 1.96
5.34 1.82
5.23 1.84
5.12 1.86
5.07 1.87
5.01 1.88
4.90 1.90
5.34 1.82
5.23 1.84
5.12 1.86
5.07 1.87
5.01 1.88
4.90 1.90
5.36 1.82
5.25 1.84
5.14 1.86
5.09 1.87
5.03 1.88
4.92 1.90
5.34 1.82
5.23 1.84
5.12 1.86
5.07 1.87
5.01 1.88
4.90 1.90
5.36 1.82
5.25 1.84
5.14 1.86
5.09 1.87
5.03 1.88
4.92 1.90
5.38 1.82
5.27 1.84
5.16 1.86
5.10 1.87
5.05 1.88
4.94 1.90
5.34 1.82
5.23 1.84
5.12 1.86
5.07 1.87
5.01 1.88
4.90 1.90
5.36 1.82
5.25 1.84
5.14 1.86
5.09 1.87
5.03 1.88
4.92 1.90

Outdoor air temp.:CWB


-5C
0C
6C
TC
PI
TC
PI
TC
PI
kW
kW
kW
kW
kW
kW
5.63 2.09 6.44 2.19 7.42 2.31
5.53 2.12 6.34 2.21 7.32 2.33
5.43 2.14 6.24 2.23 7.22 2.35
5.38 2.15 6.19 2.24 7.17 2.36
5.33 2.16 6.14 2.26 7.12 2.37
5.23 2.18 6.04 2.28 7.02 2.39
6.22 1.97 7.12 2.06 8.20 2.17
6.11 1.99 7.01 2.08 8.09 2.19
6.00 2.01 6.90 2.10 7.98 2.21
5.94 2.02 6.84 2.11 7.92 2.22
5.89 2.03 6.79 2.12 7.87 2.23
5.78 2.05 6.68 2.14 7.76 2.25
6.25 1.91 7.15 2.00 8.24 2.10
6.14 1.93 7.04 2.01 8.13 2.12
6.03 1.95 6.93 2.03 8.02 2.14
5.97 1.96 6.88 2.04 7.96 2.15
5.92 1.97 6.82 2.05 7.91 2.16
5.81 1.98 6.71 2.07 7.80 2.18
6.25 1.91 7.15 2.00 8.24 2.10
6.14 1.93 7.04 2.01 8.13 2.12
6.03 1.95 6.93 2.03 8.02 2.14
5.97 1.96 6.88 2.04 7.96 2.15
5.92 1.97 6.82 2.05 7.91 2.16
5.81 1.98 6.71 2.07 7.80 2.18
6.27 1.91 7.18 2.00 8.27 2.10
6.16 1.93 7.07 2.01 8.16 2.12
6.05 1.95 6.96 2.03 8.05 2.14
5.99 1.96 6.90 2.04 7.99 2.15
5.94 1.97 6.85 2.05 7.94 2.16
5.83 1.98 6.74 2.07 7.83 2.18
6.25 1.91 7.15 2.00 8.24 2.10
6.14 1.93 7.04 2.01 8.13 2.12
6.03 1.95 6.93 2.03 8.02 2.14
5.97 1.96 6.88 2.04 7.96 2.15
5.92 1.97 6.82 2.05 7.91 2.16
5.81 1.98 6.71 2.07 7.80 2.18
6.27 1.91 7.18 2.00 8.27 2.10
6.16 1.93 7.07 2.01 8.16 2.12
6.05 1.95 6.96 2.03 8.05 2.14
5.99 1.96 6.90 2.04 7.99 2.15
5.94 1.97 6.85 2.05 7.94 2.16
5.83 1.98 6.74 2.07 7.83 2.18
6.30 1.91 7.21 2.00 8.30 2.10
6.18 1.93 7.10 2.01 8.19 2.12
6.07 1.95 6.99 2.03 8.08 2.14
6.02 1.96 6.93 2.04 8.02 2.15
5.96 1.97 6.87 2.05 7.97 2.16
5.85 1.98 6.76 2.07 7.86 2.18
6.25 1.91 7.15 2.00 8.24 2.10
6.14 1.93 7.04 2.01 8.13 2.12
6.03 1.95 6.93 2.03 8.02 2.14
5.97 1.96 6.88 2.04 7.96 2.15
5.92 1.97 6.82 2.05 7.91 2.16
5.81 1.98 6.71 2.07 7.80 2.18
6.27 1.91 7.18 2.00 8.27 2.10
6.16 1.93 7.07 2.01 8.16 2.12
6.05 1.95 6.96 2.03 8.05 2.14
5.99 1.96 6.90 2.04 7.99 2.15
5.94 1.97 6.85 2.05 7.94 2.16
5.83 1.98 6.74 2.07 7.83 2.18

10C
TC
PI
kW
kW
8.07 2.39
7.97 2.41
7.87 2.43
7.82 2.44
7.77 2.45
7.67 2.47
8.92 2.24
8.81 2.26
8.70 2.28
8.65 2.29
8.59 2.30
8.48 2.32
8.97 2.17
8.86 2.19
8.74 2.21
8.69 2.22
8.63 2.23
8.52 2.25
8.97 2.17
8.86 2.19
8.74 2.21
8.69 2.22
8.63 2.23
8.52 2.25
9.00 2.17
8.89 2.19
8.78 2.21
8.72 2.22
8.67 2.23
8.55 2.25
8.97 2.17
8.86 2.19
8.74 2.21
8.69 2.22
8.63 2.23
8.52 2.25
9.00 2.17
8.89 2.19
8.78 2.21
8.72 2.22
8.67 2.23
8.55 2.25
9.03 2.17
8.92 2.19
8.81 2.21
8.75 2.22
8.70 2.23
8.59 2.25
8.97 2.17
8.86 2.19
8.74 2.21
8.69 2.22
8.63 2.23
8.52 2.25
9.00 2.17
8.89 2.19
8.78 2.21
8.72 2.22
8.67 2.23
8.55 2.25

15C
TC
PI
kW
kW
8.89 2.48
8.79 2.50
8.69 2.52
8.64 2.53
8.59 2.55
8.49 2.57
9.82 2.33
9.71 2.35
9.60 2.37
9.55 2.38
9.49 2.39
9.38 2.41
9.87 2.26
9.76 2.28
9.65 2.30
9.59 2.31
9.54 2.32
9.43 2.34
9.87 2.26
9.76 2.28
9.65 2.30
9.59 2.31
9.54 2.32
9.43 2.34
9.91 2.26
9.80 2.28
9.69 2.30
9.63 2.31
9.58 2.32
9.46 2.34
9.87 2.26
9.76 2.28
9.65 2.30
9.59 2.31
9.54 2.32
9.43 2.34
9.91 2.26
9.80 2.28
9.69 2.30
9.63 2.31
9.58 2.32
9.46 2.34
9.95 2.26
9.83 2.28
9.72 2.30
9.67 2.31
9.61 2.32
9.50 2.34
9.87 2.26
9.76 2.28
9.65 2.30
9.59 2.31
9.54 2.32
9.43 2.34
9.91 2.26
9.80 2.28
9.69 2.30
9.63 2.31
9.58 2.32
9.46 2.34

69

Capacity Tables

Combination
(Capacity)
2.0+2.0+5.0

EDAU12-722

Indoor
air temp.
CDB
16.0
18.0
20.0
21.0
22.0
24.0

Symbols

-15C
TC
PI
kW
kW
4.59 1.65
4.48 1.67
4.36 1.69
4.31 1.70
4.25 1.71
4.13 1.72

-10C
TC
PI
kW
kW
5.53 1.73
5.42 1.75
5.30 1.77
5.24 1.78
5.19 1.79
5.07 1.81

Outdoor air temp.:CWB


-5C
0C
6C
TC
PI
TC
PI
TC
PI
kW
kW
kW
kW
kW
kW
6.47 1.82 7.40 1.90 8.53 2.00
6.35 1.84 7.29 1.92 8.41 2.02
6.24 1.86 7.18 1.94 8.30 2.04
6.18 1.86 7.12 1.95 8.24 2.05
6.12 1.87 7.06 1.96 8.19 2.06
6.01 1.89 6.95 1.98 8.07 2.08

10C
15C
TC
PI
TC
PI
kW
kW
kW
kW
9.28 2.07 10.22 2.15
9.16 2.09 10.10 2.17
9.05 2.11 9.99 2.19
8.99 2.12 9.93 2.20
8.94 2.13 9.87 2.21
8.82 2.14 9.76 2.23

NOTE:

TC

: Total capacity

(kW)

PI

: Power input

(kW)

Capacities are based on the following conditions.


Corresponding refrigerant piping length : 7.5m
Level difference : 0m
3D055056
3D055057

70

SUPER MULTI NX E-Series Heat Pump

EDAU12-722

Capacity Tables

[Cooling Capacity 50Hz 240V]


Combination
(Capacity)
2.0

2.5

3.5

5.0

2.0+2.0

2.0+2.5

2.0+3.5

2.0+5.0

2.5+2.5

Outdoor
air temp.
CDB
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0

SUPER MULTI NX E-Series Heat Pump

14C
TC
PI
kW
kW
2.63
0.55
2.63
0.59
2.59
0.69
2.51
0.71
2.38
0.76
2.30
0.79
2.22
0.82
2.63
0.55
2.63
0.59
2.63
0.64
2.63
0.69
2.63
0.78
2.63
0.85
2.53
0.88
3.00
0.69
3.00
0.74
3.00
0.87
3.00
0.94
3.00
1.07
3.00
1.17
3.00
1.27
5.32
1.48
5.32
1.60
5.29
1.95
5.13
2.02
4.86
2.15
4.70
2.23
4.43
2.16
5.26
1.27
5.26
1.37
5.26
1.67
5.26
1.83
5.00
1.95
4.83
2.03
4.66
2.10
5.26
1.27
5.26
1.37
5.26
1.67
5.26
1.83
5.22
2.19
5.05
2.27
4.72
2.16
5.63
1.46
5.63
1.58
5.63
1.94
5.52
2.06
5.23
2.19
5.06
2.27
4.73
2.16
6.95
1.70
6.76
1.76
6.31
1.92
6.11
1.99
5.79
2.12
5.60
2.20
5.27
2.16
5.26
1.32
5.26
1.42
5.26
1.72
5.26
1.89
5.22
2.19
5.05
2.27
4.72
2.16

16C
TC
PI
kW
kW
2.99
0.62
2.91
0.64
2.72
0.70
2.64
0.72
2.51
0.77
2.43
0.80
2.35
0.83
3.23
0.63
3.23
0.67
3.11
0.75
3.02
0.78
2.87
0.83
2.77
0.86
2.68
0.89
3.68
0.87
3.68
0.94
3.68
1.11
3.68
1.20
3.68
1.37
3.68
1.50
3.68
1.64
6.10
1.76
5.94
1.82
5.56
1.98
5.40
2.05
5.13
2.18
4.97
2.26
4.66
2.16
6.27
1.60
6.10
1.66
5.71
1.80
5.55
1.87
5.27
1.98
5.10
2.06
4.94
2.14
6.46
1.75
6.38
1.86
5.97
2.02
5.80
2.09
5.51
2.22
5.34
2.31
4.96
2.16
6.56
1.79
6.39
1.86
5.98
2.02
5.81
2.09
5.52
2.22
5.34
2.31
4.97
2.16
7.27
1.73
7.08
1.80
6.63
1.95
6.43
2.02
6.11
2.15
5.92
2.23
5.54
2.16
6.46
1.75
6.38
1.86
5.97
2.02
5.80
2.09
5.51
2.22
5.34
2.31
4.96
2.16

Indoor air temp.:CWB


18C
19C
TC
PI
TC
PI
kW
kW
kW
kW
3.12
0.63
3.18
0.64
3.04
0.65
3.10
0.66
2.85
0.71
2.92
0.72
2.84
0.74
2.77
0.73
2.64
0.78
2.71
0.79
2.56
0.81
2.63
0.82
2.48
0.84
2.55
0.85
3.56
0.68
3.63
0.69
3.47
0.71
3.54
0.71
3.26
0.77
3.33
0.77
3.17
0.79
3.24
0.80
3.01
0.84
3.09
0.85
2.92
0.87
3.00
0.88
2.83
0.91
2.91
0.91
4.42
1.08
4.81
1.20
4.42
1.16
4.81
1.29
4.42
1.39
4.65
1.46
4.42
1.50
4.52
1.51
4.21
1.59
4.31
1.60
4.08
1.65
4.18
1.66
3.95
1.71
4.06
1.72
6.37
1.79
6.50
1.81
6.21
1.86
6.34
1.87
5.83
2.01
5.96
2.03
5.67
2.09
5.80
2.10
5.40
2.21
5.53
2.23
5.23
2.30
5.37
2.31
4.88
2.16
4.99
2.16
6.54
1.63
6.68
1.65
6.38
1.69
6.52
1.70
5.99
1.83
6.13
1.85
5.82
1.90
5.96
1.91
5.55
2.01
5.68
2.03
5.38
2.09
5.52
2.10
5.20
2.16
5.32
2.16
6.84
1.83
6.98
1.84
6.67
1.89
6.81
1.91
6.26
2.05
6.40
2.07
6.09
2.13
6.23
2.14
5.80
2.26
5.94
2.27
5.62
2.34
5.77
2.36
5.19
2.16
5.31
2.16
6.85
1.83
7.00
1.84
6.68
1.89
6.82
1.91
6.27
2.05
6.41
2.07
6.10
2.13
6.24
2.14
5.81
2.26
5.95
2.27
5.63
2.34
5.78
2.36
5.20
2.16
5.31
2.16
7.59
1.77
7.75
1.78
7.39
1.83
7.55
1.85
6.94
1.98
7.10
2.00
6.75
2.06
6.91
2.07
6.43
2.18
6.59
2.20
6.24
2.26
6.40
2.28
5.80
2.16
5.93
2.16
6.84
1.83
6.98
1.84
6.67
1.89
6.81
1.91
6.26
2.05
6.40
2.07
6.09
2.13
6.23
2.14
5.80
2.26
5.94
2.27
5.62
2.34
5.77
2.36
5.19
2.16
5.31
2.16

22C
TC
PI
kW
kW
3.38
0.66
3.30
0.68
3.12
0.73
3.04
0.76
2.90
0.80
2.82
0.83
2.75
0.86
3.86
0.71
3.77
0.73
3.55
0.79
3.46
0.82
3.31
0.87
3.22
0.90
3.13
0.93
5.38
1.34
5.25
1.38
4.96
1.50
4.83
1.55
4.62
1.64
4.50
1.70
4.37
1.76
6.90
1.86
6.74
1.92
6.36
2.08
6.20
2.15
5.93
2.28
5.77
2.36
5.32
2.16
7.09
1.69
6.93
1.75
6.54
1.89
6.37
1.96
6.09
2.08
5.93
2.15
5.67
2.16
7.41
1.90
7.24
1.96
6.83
2.12
6.66
2.19
6.37
2.33
6.20
2.41
5.64
2.16
7.43
1.90
7.25
1.96
6.85
2.12
6.67
2.19
6.38
2.33
6.21
2.41
5.65
2.16
8.22
1.83
8.03
1.89
7.58
2.05
7.39
2.12
7.07
2.25
6.87
2.33
6.30
2.16
7.41
1.90
7.24
1.96
6.83
2.12
6.66
2.19
6.37
2.33
6.20
2.41
5.64
2.16

24C
TC
PI
kW
kW
3.51
0.67
3.43
0.69
3.25
0.74
3.17
0.77
3.03
0.82
2.96
0.84
2.88
0.87
4.01
0.72
3.91
0.75
3.70
0.81
3.61
0.83
3.46
0.88
3.37
0.91
3.28
0.95
5.59
1.36
5.46
1.41
5.17
1.52
5.04
1.57
4.83
1.66
4.70
1.72
4.58
1.78
7.17
1.89
7.01
1.96
6.63
2.11
6.47
2.19
6.20
2.32
6.04
2.40
5.52
2.16
7.37
1.72
7.20
1.78
6.81
1.92
6.65
1.99
6.37
2.11
6.20
2.18
5.90
2.16
7.70
1.93
7.53
1.99
7.12
2.15
6.95
2.23
6.66
2.36
6.48
2.44
5.86
2.16
7.71
1.93
7.54
1.99
7.13
2.15
6.96
2.23
6.67
2.36
6.49
2.44
5.87
2.16
8.54
1.87
8.35
1.93
7.90
2.08
7.71
2.15
7.38
2.28
7.19
2.36
6.54
2.16
7.70
1.93
7.53
1.99
7.12
2.15
6.95
2.23
6.66
2.36
6.48
2.44
5.86
2.16

71

Capacity Tables

Combination
(Capacity)
2.5+3.5

2.5+5.0

3.5+3.5

3.5+5.0

2.0+2.0+2.0

2.0+2.0+2.5

2.0+2.0+3.5

2.0+2.5+2.5

2.0+2.5+3.5

72

EDAU12-722

Outdoor
air temp.
CDB
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0

14C
TC
PI
kW
kW
5.63
1.49
5.63
1.61
5.63
1.97
5.62
2.16
5.32
2.30
5.15
2.39
4.74
2.16
6.95
1.70
6.76
1.76
6.31
1.92
6.11
1.99
5.79
2.12
5.60
2.20
5.27
2.16
6.00
1.64
6.00
1.78
5.84
2.08
5.66
2.16
5.36
2.30
5.19
2.39
4.77
2.16
6.96
1.71
6.77
1.77
6.32
1.93
6.12
2.00
5.80
2.13
5.61
2.21
5.27
2.16
7.08
1.78
6.88
1.84
6.43
2.00
6.23
2.08
5.90
2.21
5.70
2.29
5.28
2.16
7.08
1.78
6.88
1.84
6.43
2.00
6.23
2.08
5.90
2.21
5.70
2.29
5.28
2.16
7.10
1.78
6.90
1.84
6.44
2.00
6.25
2.08
5.92
2.21
5.72
2.29
5.29
2.16
7.08
1.78
6.88
1.84
6.43
2.00
6.23
2.08
5.90
2.21
5.70
2.29
5.28
2.16
7.10
1.78
6.90
1.84
6.44
2.00
6.25
2.08
5.92
2.21
5.72
2.29
5.29
2.16

16C
TC
PI
kW
kW
6.68
1.89
6.50
1.95
6.09
2.12
5.91
2.20
5.62
2.34
5.44
2.42
4.97
2.16
7.27
1.73
7.08
1.80
6.63
1.95
6.43
2.02
6.11
2.15
5.92
2.23
5.54
2.16
6.73
1.89
6.55
1.95
6.14
2.12
5.96
2.20
5.66
2.34
5.48
2.42
5.01
2.16
7.28
1.74
7.09
1.80
6.64
1.96
6.44
2.03
6.12
2.16
5.93
2.24
5.54
2.16
7.41
1.81
7.21
1.87
6.75
2.04
6.55
2.11
6.23
2.24
6.03
2.33
5.54
2.16
7.41
1.81
7.21
1.87
6.75
2.04
6.55
2.11
6.23
2.24
6.03
2.33
5.54
2.16
7.43
1.81
7.23
1.87
6.77
2.04
6.57
2.11
6.24
2.24
6.05
2.33
5.56
2.16
7.41
1.81
7.21
1.87
6.75
2.04
6.55
2.11
6.23
2.24
6.03
2.33
5.54
2.16
7.43
1.81
7.23
1.87
6.77
2.04
6.57
2.11
6.24
2.24
6.05
2.33
5.56
2.16

Indoor air temp.:CWB


18C
19C
TC
PI
TC
PI
kW
kW
kW
kW
6.97
1.92
7.12
1.94
6.80
1.99
6.94
2.01
6.38
2.16
6.53
2.17
6.20
2.23
6.35
2.25
5.91
2.37
6.05
2.39
5.73
2.46
5.88
2.48
5.20
2.16
5.32
2.16
7.59
1.77
7.75
1.78
7.39
1.83
7.55
1.85
6.94
1.98
7.10
2.00
6.75
2.06
6.91
2.07
6.43
2.18
6.59
2.20
6.24
2.26
6.40
2.28
5.80
2.16
5.93
2.16
7.03
1.92
7.17
1.94
6.85
1.99
7.00
2.01
6.43
2.16
6.58
2.17
6.25
2.23
6.40
2.25
5.95
2.37
6.10
2.39
5.78
2.46
5.92
2.48
5.24
2.16
5.36
2.16
7.60
1.78
7.76
1.79
7.41
1.84
7.56
1.85
6.95
1.99
7.11
2.01
6.76
2.07
6.92
2.08
6.44
2.19
6.60
2.21
6.25
2.27
6.40
2.29
5.80
2.16
5.92
2.16
7.73
1.84
7.89
1.86
7.53
1.91
7.70
1.93
7.07
2.07
7.24
2.09
6.88
2.15
7.04
2.16
6.55
2.28
6.71
2.29
6.35
2.36
6.52
2.38
5.80
2.16
5.93
2.16
7.73
1.84
7.89
1.86
7.53
1.91
7.70
1.93
7.07
2.07
7.24
2.09
6.88
2.15
7.04
2.16
6.55
2.28
6.71
2.29
6.35
2.36
6.52
2.38
5.80
2.16
5.93
2.16
7.75
1.84
7.91
1.86
7.55
1.91
7.72
1.93
7.09
2.07
7.26
2.09
6.90
2.15
7.06
2.16
6.57
2.28
6.73
2.29
6.37
2.36
6.53
2.38
5.82
2.16
5.94
2.16
7.73
1.84
7.89
1.86
7.53
1.91
7.70
1.93
7.07
2.07
7.24
2.09
6.88
2.15
7.04
2.16
6.55
2.28
6.71
2.29
6.35
2.36
6.52
2.38
5.80
2.16
5.93
2.16
7.75
1.84
7.91
1.86
7.55
1.91
7.72
1.93
7.09
2.07
7.26
2.09
6.90
2.15
7.06
2.16
6.57
2.28
6.73
2.29
6.37
2.36
6.53
2.38
5.82
2.16
5.94
2.16

22C
TC
PI
kW
kW
7.56
1.99
7.38
2.06
6.97
2.23
6.79
2.31
6.49
2.44
6.32
2.53
5.65
2.16
8.22
1.83
8.03
1.89
7.58
2.05
7.39
2.12
7.07
2.25
6.87
2.33
6.30
2.16
7.62
1.99
7.44
2.06
7.02
2.23
6.84
2.31
6.54
2.44
6.37
2.53
5.69
2.16
8.24
1.84
8.04
1.90
7.59
2.06
7.40
2.13
7.08
2.26
6.88
2.34
6.30
2.16
8.38
1.91
8.18
1.98
7.72
2.14
7.53
2.21
7.20
2.35
7.00
2.43
6.30
2.16
8.38
1.91
8.18
1.98
7.72
2.14
7.53
2.21
7.20
2.35
7.00
2.43
6.30
2.16
8.40
1.91
8.21
1.98
7.75
2.14
7.55
2.21
7.22
2.35
7.02
2.43
6.31
2.16
8.38
1.91
8.18
1.98
7.72
2.14
7.53
2.21
7.20
2.35
7.00
2.43
6.30
2.16
8.40
1.91
8.21
1.98
7.75
2.14
7.55
2.21
7.22
2.35
7.02
2.43
6.31
2.16

24C
TC
PI
kW
kW
7.85
2.03
7.67
2.10
7.26
2.26
7.08
2.34
6.79
2.48
6.61
2.57
5.87
2.16
8.54
1.87
8.35
1.93
7.90
2.08
7.71
2.15
7.38
2.28
7.19
2.36
6.54
2.16
7.91
2.03
7.73
2.10
7.32
2.26
7.14
2.34
6.84
2.48
6.66
2.57
5.91
2.16
8.55
1.88
8.36
1.94
7.91
2.09
7.72
2.17
7.39
2.29
7.20
2.37
6.54
2.16
8.70
1.95
8.51
2.01
8.05
2.17
7.85
2.25
7.52
2.38
7.33
2.47
6.54
2.16
8.70
1.95
8.51
2.01
8.05
2.17
7.85
2.25
7.52
2.38
7.33
2.47
6.54
2.16
8.73
1.95
8.53
2.01
8.07
2.17
7.87
2.25
7.54
2.38
7.35
2.47
6.55
2.16
8.70
1.95
8.51
2.01
8.05
2.17
7.85
2.25
7.52
2.38
7.33
2.47
6.54
2.16
8.73
1.95
8.53
2.01
8.07
2.17
7.87
2.25
7.54
2.38
7.35
2.47
6.55
2.16

SUPER MULTI NX E-Series Heat Pump

EDAU12-722

Combination
(Capacity)
2.0+3.5+3.5

2.5+2.5+2.5

2.5+2.5+3.5

2.0+2.0+5.0

Capacity Tables

Outdoor
air temp.
CDB
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0

Symbols

14C
TC
PI
kW
kW
7.11
1.78
6.91
1.84
6.45
2.00
6.26
2.08
5.93
2.21
5.73
2.29
5.30
2.16
7.08
1.78
6.88
1.84
6.43
2.00
6.23
2.08
5.90
2.21
5.70
2.29
5.28
2.16
7.10
1.78
6.90
1.84
6.44
2.00
6.25
2.08
5.92
2.21
5.72
2.29
5.29
2.16
7.34
1.80
7.14
1.86
6.66
2.03
6.46
2.10
6.12
2.24
5.92
2.32
5.44
2.16

16C
TC
PI
kW
kW
7.44
1.81
7.24
1.87
6.78
2.04
6.58
2.11
6.25
2.24
6.05
2.33
5.57
2.16
7.41
1.81
7.21
1.87
6.75
2.04
6.55
2.11
6.23
2.24
6.03
2.33
5.54
2.16
7.43
1.81
7.23
1.87
6.77
2.04
6.57
2.11
6.24
2.24
6.05
2.33
5.56
2.16
7.68
1.83
7.48
1.90
7.00
2.06
6.80
2.14
6.46
2.27
6.25
2.36
5.70
2.16

Indoor air temp.:CWB


18C
19C
TC
PI
TC
PI
kW
kW
kW
kW
7.76
1.84
7.93
1.86
7.57
1.91
7.73
1.93
7.10
2.07
7.27
2.09
6.91
2.15
7.07
2.16
6.58
2.28
6.74
2.29
6.38
2.36
6.54
2.38
5.82
2.16
5.95
2.16
7.73
1.84
7.89
1.86
7.53
1.91
7.70
1.93
7.07
2.07
7.24
2.09
6.88
2.15
7.04
2.16
6.55
2.28
6.71
2.29
6.35
2.36
6.52
2.38
5.80
2.16
5.93
2.16
7.75
1.84
7.91
1.86
7.55
1.91
7.72
1.93
7.09
2.07
7.26
2.09
6.90
2.15
7.06
2.16
6.57
2.28
6.73
2.29
6.37
2.36
6.53
2.38
5.82
2.16
5.94
2.16
8.02
1.87
8.18
1.89
7.81
1.93
7.98
1.95
7.34
2.10
7.50
2.12
7.13
2.17
7.30
2.19
6.79
2.31
6.96
2.33
6.59
2.39
6.76
2.41
5.97
2.16
6.10
2.16

22C
TC
PI
kW
kW
8.41
1.91
8.22
1.98
7.76
2.14
7.56
2.21
7.23
2.35
7.03
2.43
6.32
2.16
8.38
1.91
8.18
1.98
7.72
2.14
7.53
2.21
7.20
2.35
7.00
2.43
6.30
2.16
8.40
1.91
8.21
1.98
7.75
2.14
7.55
2.21
7.22
2.35
7.02
2.43
6.31
2.16
8.69
1.94
8.48
2.00
8.01
2.17
7.80
2.24
7.46
2.38
7.26
2.46
6.47
2.16

24C
TC
PI
kW
kW
8.74
1.95
8.54
2.01
8.08
2.17
7.88
2.25
7.56
2.38
7.36
2.47
6.56
2.16
8.70
1.95
8.51
2.01
8.05
2.17
7.85
2.25
7.52
2.38
7.33
2.47
6.54
2.16
8.73
1.95
8.53
2.01
8.07
2.17
7.87
2.25
7.54
2.38
7.35
2.47
6.55
2.16
9.02
1.97
8.82
2.04
8.34
2.20
8.14
2.28
7.80
2.41
7.60
2.50
6.72
2.16

NOTE:

TC

: Total capacity

(kW)

PI

: Power input

(kW)

Capacities are based on the following conditions.


Corresponding refrigerant piping length : 7.5m
Level difference : 0m
3D055054
3D055055

SUPER MULTI NX E-Series Heat Pump

73

Capacity Tables

EDAU12-722

[Heating Capacity 50Hz 240V]


Combination
(Capacity)
2.0

2.5

3.5

5.0

2.0+2.0

2.0+2.5

2.0+3.5

2.0+5.0

2.5+2.5

2.5+3.5

2.5+5.0

74

Indoor
air temp.
CDB
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0

-15C
TC
PI
kW
kW
2.08 0.97
2.02 0.98
1.97 0.99
1.95 1.00
1.92 1.00
1.87 1.01
2.21 1.02
2.16 1.03
2.10 1.04
2.08 1.05
2.05 1.05
1.99 1.06
2.67 1.36
2.60 1.37
2.53 1.39
2.50 1.40
2.47 1.40
2.40 1.42
3.76 2.03
3.66 2.05
3.57 2.08
3.52 2.09
3.48 2.10
3.38 2.12
3.87 1.84
3.78 1.87
3.68 1.89
3.63 1.90
3.58 1.91
3.49 1.93
3.87 1.84
3.78 1.87
3.68 1.89
3.63 1.90
3.58 1.91
3.49 1.93
3.90 1.84
3.80 1.87
3.70 1.89
3.65 1.90
3.60 1.91
3.51 1.93
4.40 1.80
4.29 1.82
4.18 1.84
4.12 1.85
4.07 1.86
3.96 1.88
3.87 1.87
3.78 1.89
3.68 1.91
3.63 1.92
3.58 1.93
3.49 1.95
3.98 1.91
3.88 1.93
3.78 1.95
3.73 1.96
3.68 1.97
3.58 1.99
4.40 1.80
4.29 1.82
4.18 1.84
4.12 1.85
4.07 1.86
3.96 1.88

-10C
TC
PI
kW
kW
2.50 1.02
2.45 1.03
2.39 1.04
2.37 1.05
2.34 1.05
2.29 1.06
2.67 1.07
2.61 1.08
2.55 1.09
2.53 1.10
2.50 1.11
2.44 1.12
3.21 1.43
3.14 1.44
3.08 1.46
3.05 1.47
3.01 1.47
2.95 1.49
4.52 2.13
4.43 2.16
4.34 2.18
4.29 2.19
4.24 2.20
4.15 2.22
4.66 1.94
4.57 1.96
4.47 1.98
4.42 1.99
4.37 2.00
4.28 2.02
4.66 1.94
4.57 1.96
4.47 1.98
4.42 1.99
4.37 2.00
4.28 2.02
4.69 1.94
4.59 1.96
4.50 1.98
4.45 1.99
4.40 2.00
4.30 2.02
5.30 1.89
5.19 1.91
5.08 1.93
5.02 1.94
4.97 1.95
4.86 1.97
4.66 1.96
4.57 1.98
4.47 2.01
4.42 2.02
4.37 2.03
4.28 2.05
4.79 2.01
4.69 2.03
4.59 2.05
4.54 2.06
4.49 2.07
4.39 2.09
5.30 1.89
5.19 1.91
5.08 1.93
5.02 1.94
4.97 1.95
4.86 1.97

Outdoor air temp.:CWB


-5C
0C
6C
TC
PI
TC
PI
TC
PI
kW
kW
kW
kW
kW
kW
2.92 1.07 3.35 1.12 3.85 1.18
2.87 1.08 3.29 1.13 3.80 1.19
2.82 1.09 3.24 1.14 3.75 1.20
2.79 1.10 3.22 1.15 3.72 1.21
2.77 1.10 3.19 1.15 3.70 1.21
2.71 1.11 3.14 1.16 3.65 1.22
3.12 1.12 3.57 1.18 4.11 1.24
3.06 1.13 3.51 1.19 4.06 1.25
3.01 1.15 3.46 1.20 4.00 1.26
2.98 1.15 3.43 1.20 3.97 1.27
2.95 1.16 3.40 1.21 3.94 1.27
2.90 1.17 3.35 1.22 3.89 1.28
3.76 1.50 4.30 1.57 4.95 1.65
3.69 1.51 4.23 1.58 4.89 1.66
3.62 1.53 4.17 1.60 4.82 1.68
3.59 1.54 4.13 1.60 4.79 1.69
3.56 1.54 4.10 1.61 4.75 1.70
3.49 1.56 4.03 1.63 4.69 1.71
5.29 2.24 6.06 2.34 6.98 2.46
5.20 2.26 5.96 2.36 6.88 2.49
5.10 2.28 5.87 2.39 6.79 2.51
5.06 2.29 5.82 2.40 6.74 2.52
5.01 2.31 5.78 2.41 6.70 2.53
4.92 2.33 5.68 2.43 6.60 2.56
5.45 2.03 6.24 2.13 7.19 2.24
5.36 2.05 6.15 2.15 7.10 2.26
5.26 2.07 6.05 2.17 7.00 2.28
5.21 2.08 6.00 2.18 6.95 2.29
5.16 2.09 5.95 2.19 6.90 2.30
5.07 2.11 5.86 2.21 6.81 2.32
5.45 2.03 6.24 2.13 7.19 2.24
5.36 2.05 6.15 2.15 7.10 2.26
5.26 2.07 6.05 2.17 7.00 2.28
5.21 2.08 6.00 2.18 6.95 2.29
5.16 2.09 5.95 2.19 6.90 2.30
5.07 2.11 5.86 2.21 6.81 2.32
5.49 2.03 6.28 2.13 7.23 2.24
5.39 2.05 6.18 2.15 7.14 2.26
5.29 2.07 6.09 2.17 7.04 2.28
5.24 2.08 6.04 2.18 6.99 2.29
5.19 2.09 5.99 2.19 6.94 2.30
5.10 2.11 5.89 2.21 6.85 2.32
6.19 1.98 7.09 2.07 8.17 2.18
6.08 2.00 6.98 2.09 8.06 2.20
5.98 2.02 6.87 2.11 7.95 2.22
5.92 2.03 6.82 2.12 7.90 2.23
5.87 2.04 6.76 2.13 7.84 2.24
5.76 2.06 6.65 2.15 7.73 2.26
5.45 2.06 6.24 2.15 7.19 2.27
5.36 2.08 6.15 2.18 7.10 2.29
5.26 2.10 6.05 2.20 7.00 2.31
5.21 2.11 6.00 2.21 6.95 2.32
5.16 2.12 5.95 2.22 6.90 2.33
5.07 2.14 5.86 2.24 6.81 2.35
5.60 2.10 6.41 2.20 7.39 2.32
5.50 2.12 6.32 2.22 7.29 2.34
5.40 2.15 6.22 2.24 7.19 2.36
5.35 2.16 6.17 2.25 7.14 2.37
5.30 2.17 6.12 2.26 7.09 2.38
5.21 2.19 6.02 2.29 6.99 2.40
6.19 1.98 7.09 2.07 8.17 2.18
6.08 2.00 6.98 2.09 8.06 2.20
5.98 2.02 6.87 2.11 7.95 2.22
5.92 2.03 6.82 2.12 7.90 2.23
5.87 2.04 6.76 2.13 7.84 2.24
5.76 2.06 6.65 2.15 7.73 2.26

10C
TC
PI
kW
kW
4.19 1.22
4.14 1.23
4.09 1.24
4.06 1.24
4.04 1.25
3.99 1.26
4.47 1.28
4.42 1.29
4.36 1.30
4.33 1.31
4.31 1.31
4.25 1.32
5.39 1.71
5.32 1.72
5.26 1.74
5.22 1.74
5.19 1.75
5.12 1.77
7.59 2.55
7.50 2.57
7.40 2.59
7.36 2.60
7.31 2.62
7.22 2.64
7.83 2.31
7.73 2.33
7.63 2.36
7.58 2.37
7.54 2.38
7.44 2.40
7.83 2.31
7.73 2.33
7.63 2.36
7.58 2.37
7.54 2.38
7.44 2.40
7.87 2.31
7.77 2.33
7.68 2.36
7.63 2.37
7.58 2.38
7.48 2.40
8.89 2.25
8.78 2.27
8.67 2.29
8.61 2.30
8.56 2.31
8.45 2.33
7.83 2.34
7.73 2.37
7.63 2.39
7.58 2.40
7.54 2.41
7.44 2.43
8.04 2.40
7.94 2.42
7.84 2.44
7.79 2.45
7.74 2.46
7.64 2.48
8.89 2.25
8.78 2.27
8.67 2.29
8.61 2.30
8.56 2.31
8.45 2.33

15C
TC
PI
kW
kW
4.62 1.27
4.56 1.28
4.51 1.29
4.49 1.29
4.46 1.30
4.41 1.31
4.92 1.33
4.87 1.34
4.81 1.35
4.79 1.36
4.76 1.36
4.70 1.38
5.93 1.77
5.87 1.79
5.80 1.80
5.77 1.81
5.73 1.82
5.67 1.83
8.36 2.65
8.26 2.67
8.17 2.70
8.12 2.71
8.08 2.72
7.98 2.74
8.62 2.41
8.52 2.43
8.42 2.45
8.37 2.46
8.33 2.47
8.23 2.49
8.62 2.41
8.52 2.43
8.42 2.45
8.37 2.46
8.33 2.47
8.23 2.49
8.67 2.41
8.57 2.43
8.47 2.45
8.42 2.46
8.37 2.47
8.28 2.49
9.79 2.34
9.68 2.36
9.57 2.38
9.51 2.39
9.46 2.40
9.35 2.42
8.62 2.44
8.52 2.46
8.42 2.48
8.37 2.49
8.33 2.50
8.23 2.52
8.85 2.49
8.75 2.51
8.65 2.53
8.60 2.55
8.55 2.56
8.45 2.58
9.79 2.34
9.68 2.36
9.57 2.38
9.51 2.39
9.46 2.40
9.35 2.42

SUPER MULTI NX E-Series Heat Pump

EDAU12-722

Combination
(Capacity)
3.5+3.5

3.5+5.0

2.0+2.0+2.0

2.0+2.0+2.5

2.0+2.0+3.5

2.0+2.5+2.5

2.0+2.5+3.5

2.0+3.5+3.5

2.5+2.5+2.5

2.5+2.5+3.5

Capacity Tables

Indoor
air temp.
CDB
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0

SUPER MULTI NX E-Series Heat Pump

-15C
TC
PI
kW
kW
4.00 1.90
3.90 1.92
3.80 1.94
3.75 1.95
3.70 1.96
3.60 1.99
4.42 1.79
4.31 1.81
4.20 1.83
4.14 1.84
4.09 1.85
3.98 1.87
4.44 1.73
4.33 1.75
4.22 1.77
4.16 1.78
4.11 1.79
3.99 1.81
4.44 1.73
4.33 1.75
4.22 1.77
4.16 1.78
4.11 1.79
3.99 1.81
4.45 1.73
4.34 1.75
4.23 1.77
4.18 1.78
4.12 1.79
4.01 1.81
4.44 1.73
4.33 1.75
4.22 1.77
4.16 1.78
4.11 1.79
3.99 1.81
4.45 1.73
4.34 1.75
4.23 1.77
4.18 1.78
4.12 1.79
4.01 1.81
4.47 1.73
4.36 1.75
4.25 1.77
4.19 1.78
4.14 1.79
4.02 1.81
4.44 1.73
4.33 1.75
4.22 1.77
4.16 1.78
4.11 1.79
3.99 1.81
4.45 1.73
4.34 1.75
4.23 1.77
4.18 1.78
4.12 1.79
4.01 1.81

-10C
TC
PI
kW
kW
4.81 2.00
4.71 2.02
4.61 2.04
4.56 2.05
4.51 2.06
4.41 2.08
5.32 1.88
5.21 1.90
5.10 1.92
5.04 1.93
4.99 1.94
4.88 1.96
5.34 1.82
5.23 1.84
5.12 1.86
5.07 1.87
5.01 1.88
4.90 1.90
5.34 1.82
5.23 1.84
5.12 1.86
5.07 1.87
5.01 1.88
4.90 1.90
5.36 1.82
5.25 1.84
5.14 1.86
5.09 1.87
5.03 1.88
4.92 1.90
5.34 1.82
5.23 1.84
5.12 1.86
5.07 1.87
5.01 1.88
4.90 1.90
5.36 1.82
5.25 1.84
5.14 1.86
5.09 1.87
5.03 1.88
4.92 1.90
5.38 1.82
5.27 1.84
5.16 1.86
5.10 1.87
5.05 1.88
4.94 1.90
5.34 1.82
5.23 1.84
5.12 1.86
5.07 1.87
5.01 1.88
4.90 1.90
5.36 1.82
5.25 1.84
5.14 1.86
5.09 1.87
5.03 1.88
4.92 1.90

Outdoor air temp.:CWB


-5C
0C
6C
TC
PI
TC
PI
TC
PI
kW
kW
kW
kW
kW
kW
5.63 2.09 6.44 2.19 7.42 2.31
5.53 2.12 6.34 2.21 7.32 2.33
5.43 2.14 6.24 2.23 7.22 2.35
5.38 2.15 6.19 2.24 7.17 2.36
5.33 2.16 6.14 2.26 7.12 2.37
5.23 2.18 6.04 2.28 7.02 2.39
6.22 1.97 7.12 2.06 8.20 2.17
6.11 1.99 7.01 2.08 8.09 2.19
6.00 2.01 6.90 2.10 7.98 2.21
5.94 2.02 6.84 2.11 7.92 2.22
5.89 2.03 6.79 2.12 7.87 2.23
5.78 2.05 6.68 2.14 7.76 2.25
6.25 1.91 7.15 2.00 8.24 2.10
6.14 1.93 7.04 2.01 8.13 2.12
6.03 1.95 6.93 2.03 8.02 2.14
5.97 1.96 6.88 2.04 7.96 2.15
5.92 1.97 6.82 2.05 7.91 2.16
5.81 1.98 6.71 2.07 7.80 2.18
6.25 1.91 7.15 2.00 8.24 2.10
6.14 1.93 7.04 2.01 8.13 2.12
6.03 1.95 6.93 2.03 8.02 2.14
5.97 1.96 6.88 2.04 7.96 2.15
5.92 1.97 6.82 2.05 7.91 2.16
5.81 1.98 6.71 2.07 7.80 2.18
6.27 1.91 7.18 2.00 8.27 2.10
6.16 1.93 7.07 2.01 8.16 2.12
6.05 1.95 6.96 2.03 8.05 2.14
5.99 1.96 6.90 2.04 7.99 2.15
5.94 1.97 6.85 2.05 7.94 2.16
5.83 1.98 6.74 2.07 7.83 2.18
6.25 1.91 7.15 2.00 8.24 2.10
6.14 1.93 7.04 2.01 8.13 2.12
6.03 1.95 6.93 2.03 8.02 2.14
5.97 1.96 6.88 2.04 7.96 2.15
5.92 1.97 6.82 2.05 7.91 2.16
5.81 1.98 6.71 2.07 7.80 2.18
6.27 1.91 7.18 2.00 8.27 2.10
6.16 1.93 7.07 2.01 8.16 2.12
6.05 1.95 6.96 2.03 8.05 2.14
5.99 1.96 6.90 2.04 7.99 2.15
5.94 1.97 6.85 2.05 7.94 2.16
5.83 1.98 6.74 2.07 7.83 2.18
6.30 1.91 7.21 2.00 8.30 2.10
6.18 1.93 7.10 2.01 8.19 2.12
6.07 1.95 6.99 2.03 8.08 2.14
6.02 1.96 6.93 2.04 8.02 2.15
5.96 1.97 6.87 2.05 7.97 2.16
5.85 1.98 6.76 2.07 7.86 2.18
6.25 1.91 7.15 2.00 8.24 2.10
6.14 1.93 7.04 2.01 8.13 2.12
6.03 1.95 6.93 2.03 8.02 2.14
5.97 1.96 6.88 2.04 7.96 2.15
5.92 1.97 6.82 2.05 7.91 2.16
5.81 1.98 6.71 2.07 7.80 2.18
6.27 1.91 7.18 2.00 8.27 2.10
6.16 1.93 7.07 2.01 8.16 2.12
6.05 1.95 6.96 2.03 8.05 2.14
5.99 1.96 6.90 2.04 7.99 2.15
5.94 1.97 6.85 2.05 7.94 2.16
5.83 1.98 6.74 2.07 7.83 2.18

10C
TC
PI
kW
kW
8.07 2.39
7.97 2.41
7.87 2.43
7.82 2.44
7.77 2.45
7.67 2.47
8.92 2.24
8.81 2.26
8.70 2.28
8.65 2.29
8.59 2.30
8.48 2.32
8.97 2.17
8.86 2.19
8.74 2.21
8.69 2.22
8.63 2.23
8.52 2.25
8.97 2.17
8.86 2.19
8.74 2.21
8.69 2.22
8.63 2.23
8.52 2.25
9.00 2.17
8.89 2.19
8.78 2.21
8.72 2.22
8.67 2.23
8.55 2.25
8.97 2.17
8.86 2.19
8.74 2.21
8.69 2.22
8.63 2.23
8.52 2.25
9.00 2.17
8.89 2.19
8.78 2.21
8.72 2.22
8.67 2.23
8.55 2.25
9.03 2.17
8.92 2.19
8.81 2.21
8.75 2.22
8.70 2.23
8.59 2.25
8.97 2.17
8.86 2.19
8.74 2.21
8.69 2.22
8.63 2.23
8.52 2.25
9.00 2.17
8.89 2.19
8.78 2.21
8.72 2.22
8.67 2.23
8.55 2.25

15C
TC
PI
kW
kW
8.89 2.48
8.79 2.50
8.69 2.52
8.64 2.53
8.59 2.55
8.49 2.57
9.82 2.33
9.71 2.35
9.60 2.37
9.55 2.38
9.49 2.39
9.38 2.41
9.87 2.26
9.76 2.28
9.65 2.30
9.59 2.31
9.54 2.32
9.43 2.34
9.87 2.26
9.76 2.28
9.65 2.30
9.59 2.31
9.54 2.32
9.43 2.34
9.91 2.26
9.80 2.28
9.69 2.30
9.63 2.31
9.58 2.32
9.46 2.34
9.87 2.26
9.76 2.28
9.65 2.30
9.59 2.31
9.54 2.32
9.43 2.34
9.91 2.26
9.80 2.28
9.69 2.30
9.63 2.31
9.58 2.32
9.46 2.34
9.95 2.26
9.83 2.28
9.72 2.30
9.67 2.31
9.61 2.32
9.50 2.34
9.87 2.26
9.76 2.28
9.65 2.30
9.59 2.31
9.54 2.32
9.43 2.34
9.91 2.26
9.80 2.28
9.69 2.30
9.63 2.31
9.58 2.32
9.46 2.34

75

Capacity Tables

Combination
(Capacity)
2.0+2.0+5.0

EDAU12-722

Indoor
air temp.
CDB
16.0
18.0
20.0
21.0
22.0
24.0

Symbols

-15C
TC
PI
kW
kW
4.59 1.65
4.48 1.67
4.36 1.69
4.31 1.70
4.25 1.71
4.13 1.72

-10C
TC
PI
kW
kW
5.53 1.73
5.42 1.75
5.30 1.77
5.24 1.78
5.19 1.79
5.07 1.81

Outdoor air temp.:CWB


-5C
0C
6C
TC
PI
TC
PI
TC
PI
kW
kW
kW
kW
kW
kW
6.47 1.82 7.40 1.90 8.53 2.00
6.35 1.84 7.29 1.92 8.41 2.02
6.24 1.86 7.18 1.94 8.30 2.04
6.18 1.86 7.12 1.95 8.24 2.05
6.12 1.87 7.06 1.96 8.19 2.06
6.01 1.89 6.95 1.98 8.07 2.08

10C
15C
TC
PI
TC
PI
kW
kW
kW
kW
9.28 2.07 10.22 2.15
9.16 2.09 10.10 2.17
9.05 2.11 9.99 2.19
8.99 2.12 9.93 2.20
8.94 2.13 9.87 2.21
8.82 2.14 9.76 2.23

NOTE:

TC

: Total capacity

(kW)

PI

: Power input

(kW)

Capacities are based on the following conditions.


Corresponding refrigerant piping length : 7.5m
Level difference : 0m
3D055058
3D055059

76

SUPER MULTI NX E-Series Heat Pump

EDAU12-722

7.1.2

Capacity Tables

3MXS68EVMA

[Cooling Capacity 50Hz 230V]


Combination
(Capacity)
2.0

2.5

3.5

5.0

6.0

2.0+2.0

2.0+2.5

2.0+3.5

2.0+5.0

Outdoor
air temp.
CDB
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0

SUPER MULTI NX E-Series Heat Pump

14C
TC
PI
kW
kW
2.59
0.55
2.51
0.57
2.35
0.62
2.27
0.64
2.15
0.69
2.08
0.71
2.01
0.74
2.63
0.54
2.63
0.57
2.63
0.68
2.63
0.73
2.63
0.84
2.63
0.91
2.63
0.99
3.00
0.62
3.00
0.67
3.00
0.78
3.00
0.84
3.00
0.96
3.00
1.04
3.00
1.13
5.32
1.47
5.32
1.59
5.32
1.95
5.20
2.06
4.93
2.19
4.76
2.27
4.60
2.36
5.60
1.59
5.60
1.72
5.60
2.11
5.60
2.33
5.32
2.49
5.15
2.59
4.93
2.56
5.05
1.31
4.91
1.35
4.58
1.47
4.44
1.53
4.21
1.63
4.07
1.69
3.93
1.75
5.26
1.40
5.19
1.49
4.85
1.62
4.70
1.68
4.45
1.79
4.30
1.86
4.15
1.93
5.63
1.63
5.63
1.77
5.63
2.18
5.49
2.29
5.20
2.43
5.02
2.53
4.83
2.56
7.14
2.06
6.94
2.14
6.48
2.33
6.28
2.41
5.95
2.57
5.75
2.66
5.46
2.56

16C
TC
PI
kW
kW
2.70
0.56
2.63
0.58
2.46
0.63
2.39
0.65
2.27
0.70
2.20
0.72
2.13
0.75
3.23
0.67
3.23
0.72
3.23
0.85
3.16
0.89
3.00
0.95
2.90
0.98
2.81
1.02
3.68
0.78
3.68
0.84
3.68
0.99
3.68
1.06
3.68
1.22
3.68
1.32
3.68
1.44
6.19
1.79
6.02
1.86
5.64
2.02
5.47
2.09
5.20
2.22
5.04
2.31
4.87
2.39
6.68
2.04
6.50
2.12
6.09
2.30
5.91
2.38
5.62
2.53
5.44
2.63
5.19
2.56
5.28
1.33
5.14
1.38
4.81
1.50
4.67
1.55
4.44
1.65
4.30
1.71
4.16
1.78
5.59
1.47
5.44
1.52
5.09
1.65
4.94
1.71
4.70
1.82
4.55
1.89
4.40
1.96
6.52
1.99
6.35
2.06
5.94
2.24
5.77
2.33
5.48
2.47
5.31
2.56
5.10
2.56
7.47
2.10
7.27
2.18
6.81
2.37
6.61
2.45
6.28
2.61
6.08
2.70
5.74
2.56

Indoor air temp.:CWB


18C
19C
TC
PI
TC
PI
kW
kW
kW
kW
2.82
0.57
2.88
0.58
2.75
0.59
2.81
0.60
2.58
0.64
2.64
0.65
2.51
0.67
2.57
0.67
2.39
0.71
2.45
0.71
2.32
0.73
2.38
0.74
2.25
0.76
2.31
0.77
3.72
0.78
3.80
0.78
3.63
0.80
3.71
0.81
3.41
0.87
3.48
0.88
3.31
0.90
3.39
0.91
3.15
0.96
3.23
0.97
3.06
0.99
3.14
1.00
2.96
1.03
3.04
1.04
4.42
0.96
4.81
1.07
4.42
1.03
4.81
1.14
4.42
1.22
4.81
1.36
4.42
1.32
4.73
1.43
4.40
1.51
4.51
1.52
4.27
1.56
4.38
1.58
4.14
1.62
4.25
1.63
6.46
1.83
6.59
1.84
6.29
1.89
6.43
1.91
5.91
2.05
6.04
2.07
5.74
2.13
5.88
2.14
5.47
2.26
5.61
2.27
5.31
2.34
5.44
2.36
5.14
2.43
5.28
2.44
6.97
2.08
7.12
2.10
6.80
2.16
6.94
2.17
6.38
2.34
6.53
2.36
6.20
2.42
6.35
2.44
5.91
2.57
6.05
2.59
5.73
2.67
5.88
2.69
5.45
2.56
5.58
2.56
5.51
1.36
5.63
1.37
5.37
1.40
5.49
1.42
5.04
1.52
5.16
1.54
4.90
1.58
5.02
1.59
4.67
1.68
4.79
1.69
4.53
1.74
4.65
1.75
4.39
1.80
4.51
1.82
5.83
1.49
5.95
1.51
5.68
1.55
5.80
1.56
5.34
1.68
5.46
1.69
5.19
1.74
5.31
1.75
4.94
1.85
5.06
1.86
4.79
1.91
4.91
1.93
4.64
1.98
4.77
2.00
6.81
2.03
6.95
2.05
6.63
2.10
6.78
2.12
6.23
2.28
6.37
2.30
6.06
2.36
6.20
2.38
5.77
2.51
5.91
2.53
5.60
2.60
5.74
2.62
5.35
2.56
5.48
2.56
7.80
2.14
7.96
2.16
7.60
2.22
7.76
2.24
7.13
2.41
7.30
2.43
6.94
2.49
7.10
2.51
6.61
2.65
6.77
2.67
6.41
2.74
6.57
2.76
6.02
2.56
6.16
2.56

22C
TC
PI
kW
kW
3.06
0.59
2.99
0.61
2.82
0.66
2.75
0.69
2.63
0.73
2.56
0.75
2.48
0.78
4.03
0.81
3.94
0.83
3.72
0.90
3.62
0.93
3.47
0.99
3.37
1.02
3.28
1.06
5.63
1.27
5.50
1.31
5.19
1.42
5.06
1.47
4.84
1.55
4.70
1.61
4.57
1.67
7.00
1.90
6.83
1.96
6.45
2.12
6.29
2.19
6.01
2.33
5.85
2.41
5.68
2.50
7.56
2.16
7.38
2.23
6.97
2.42
6.79
2.50
6.49
2.65
6.32
2.75
5.96
2.56
5.97
1.41
5.83
1.46
5.51
1.57
5.37
1.63
5.13
1.73
4.99
1.79
4.85
1.85
6.32
1.55
6.17
1.60
5.83
1.73
5.68
1.79
5.43
1.90
5.28
1.97
5.13
2.04
7.38
2.11
7.21
2.18
6.80
2.36
6.63
2.44
6.34
2.59
6.17
2.68
5.86
2.56
8.45
2.22
8.25
2.30
7.79
2.49
7.59
2.57
7.26
2.73
7.06
2.82
6.56
2.56

24C
TC
PI
kW
kW
3.18
0.60
3.11
0.62
2.94
0.67
2.87
0.70
2.75
0.74
2.67
0.76
2.60
0.79
4.19
0.82
4.10
0.85
3.88
0.92
3.78
0.95
3.62
1.00
3.53
1.04
3.43
1.08
5.85
1.29
5.72
1.33
5.41
1.44
5.27
1.49
5.05
1.58
4.92
1.63
4.79
1.69
7.27
1.93
7.10
1.99
6.72
2.15
6.56
2.23
6.28
2.36
6.12
2.44
5.95
2.53
7.85
2.20
7.67
2.27
7.26
2.46
7.08
2.54
6.79
2.69
6.61
2.79
6.20
2.56
6.21
1.43
6.07
1.48
5.74
1.60
5.60
1.66
5.36
1.75
5.22
1.81
5.08
1.88
6.56
1.58
6.42
1.63
6.07
1.76
5.92
1.82
5.67
1.93
5.53
2.00
5.38
2.07
7.66
2.15
7.49
2.22
7.09
2.40
6.91
2.48
6.63
2.62
6.45
2.72
6.10
2.56
8.78
2.26
8.58
2.34
8.12
2.53
7.92
2.61
7.59
2.77
7.39
2.86
6.82
2.56

77

Capacity Tables

Combination
(Capacity)
2.0+6.0

2.5+2.5

2.5+3.5

2.5+5.0

2.5+6.0

3.5+3.5

3.5+5.0

3.5+6.0

5.0+5.0

5.0+6.0

78

EDAU12-722

Outdoor
air temp.
CDB
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0

14C
TC
PI
kW
kW
7.62
2.27
7.41
2.35
6.92
2.56
6.71
2.65
6.35
2.82
6.14
2.93
5.73
2.56
5.26
1.44
5.26
1.56
5.26
1.90
5.26
2.09
5.00
2.24
4.84
2.32
4.67
2.41
5.63
1.68
5.63
1.82
5.63
2.24
5.63
2.47
5.39
2.69
5.21
2.79
4.96
2.56
7.29
2.17
7.09
2.25
6.62
2.45
6.41
2.54
6.08
2.70
5.87
2.80
5.52
2.56
7.64
2.33
7.43
2.42
6.94
2.63
6.72
2.73
6.37
2.90
6.16
3.01
5.74
2.56
6.00
1.75
6.00
1.90
6.00
2.34
6.00
2.58
5.84
2.91
5.65
3.02
5.33
2.56
7.67
2.36
7.46
2.44
6.96
2.66
6.75
2.76
6.40
2.93
6.18
3.05
5.75
2.56
7.95
2.56
7.73
2.65
7.21
2.88
6.99
2.99
6.62
3.18
6.39
3.14
5.94
2.56
8.16
2.42
7.93
2.51
7.40
2.73
7.18
2.84
6.80
3.02
6.57
3.13
6.05
2.56
8.34
2.51
8.11
2.61
7.57
2.83
7.34
2.94
6.95
3.13
6.70
3.14
6.17
2.56

16C
TC
PI
kW
kW
7.97
2.31
7.76
2.39
7.27
2.60
7.06
2.70
6.70
2.87
6.49
2.97
6.01
2.56
6.28
1.83
6.11
1.90
5.72
2.06
5.56
2.14
5.28
2.27
5.11
2.36
4.95
2.45
6.76
2.20
6.58
2.28
6.17
2.48
5.99
2.57
5.69
2.73
5.51
2.83
5.22
2.56
7.63
2.21
7.42
2.29
6.95
2.49
6.75
2.58
6.41
2.74
6.21
2.84
5.81
2.56
7.99
2.38
7.78
2.46
7.29
2.68
7.07
2.77
6.72
2.95
6.51
3.06
6.02
2.56
7.33
2.39
7.14
2.47
6.68
2.69
6.49
2.78
6.16
2.96
5.97
3.07
5.60
2.56
8.03
2.40
7.81
2.49
7.32
2.70
7.10
2.80
6.75
2.98
6.53
3.09
6.04
2.56
8.31
2.61
8.09
2.70
7.57
2.93
7.35
3.04
6.99
3.23
6.74
3.14
6.22
2.56
8.53
2.47
8.30
2.56
7.78
2.78
7.55
2.88
7.17
3.06
6.93
3.14
6.34
2.56
8.72
2.56
8.49
2.65
7.95
2.88
7.72
2.99
7.33
3.18
7.06
3.14
6.46
2.56

Indoor air temp.:CWB


18C
19C
TC
PI
TC
PI
kW
kW
kW
kW
8.32
2.36
8.50
2.38
8.11
2.44
8.29
2.46
7.62
2.64
7.79
2.67
7.41
2.74
7.58
2.76
7.05
2.91
7.23
2.93
6.84
3.02
7.02
3.04
6.29
2.56
6.43
2.56
6.56
1.87
6.69
1.89
6.39
1.93
6.53
1.95
6.00
2.10
6.14
2.12
5.83
2.17
5.97
2.19
5.55
2.31
5.69
2.33
5.39
2.39
5.53
2.41
5.22
2.48
5.36
2.50
7.06
2.25
7.21
2.27
6.88
2.32
7.03
2.34
6.46
2.52
6.61
2.54
6.28
2.61
6.43
2.63
5.98
2.77
6.13
2.79
5.80
2.88
5.95
2.90
5.47
2.56
5.60
2.56
7.96
2.25
8.13
2.28
7.76
2.33
7.93
2.35
7.29
2.53
7.45
2.55
7.08
2.62
7.25
2.64
6.75
2.78
6.91
2.80
6.54
2.89
6.71
2.91
6.08
2.56
6.22
2.56
8.35
2.42
8.52
2.45
8.13
2.51
8.31
2.53
7.64
2.72
7.81
2.74
7.42
2.82
7.60
2.84
7.07
2.99
7.25
3.02
6.86
3.11
7.03
3.13
6.29
2.56
6.43
2.56
7.65
2.43
7.81
2.46
7.46
2.52
7.62
2.54
7.00
2.73
7.16
2.75
6.81
2.83
6.97
2.85
6.48
3.01
6.65
3.03
6.29
3.12
6.45
3.14
5.86
2.56
5.98
2.56
8.38
2.45
8.55
2.47
8.16
2.54
8.34
2.56
7.67
2.75
7.84
2.77
7.45
2.85
7.63
2.87
7.10
3.03
7.27
3.05
6.89
3.14
7.05
3.14
6.31
2.56
6.45
2.56
8.67
2.66
8.86
2.68
8.45
2.75
8.64
2.77
7.94
2.98
8.12
3.01
7.72
3.09
7.90
3.11
7.35
3.28
7.53
3.30
7.07
3.14
7.24
3.14
6.49
2.56
6.63
2.56
8.91
2.52
9.09
2.54
8.68
2.61
8.87
2.63
8.15
2.83
8.34
2.85
7.92
2.93
8.11
2.95
7.55
3.11
7.73
3.13
7.28
3.14
7.46
3.14
6.63
2.56
6.77
2.56
9.10
2.61
9.29
2.64
8.87
2.70
9.06
2.73
8.33
2.93
8.52
2.96
8.10
3.04
8.29
3.06
7.71
3.23
7.90
3.25
7.41
3.14
7.58
3.14
6.74
2.56
6.88
2.56

22C
TC
PI
kW
kW
9.02
2.44
8.81
2.53
8.32
2.73
8.10
2.83
7.75
3.00
7.54
3.11
6.83
2.56
7.11
1.94
6.94
2.00
6.55
2.17
6.38
2.24
6.10
2.38
5.94
2.46
5.77
2.55
7.65
2.33
7.47
2.41
7.05
2.60
6.87
2.70
6.57
2.86
6.40
2.96
5.96
2.56
8.63
2.34
8.43
2.42
7.95
2.61
7.75
2.71
7.41
2.87
7.21
2.97
6.62
2.56
9.05
2.52
8.83
2.60
8.34
2.81
8.13
2.91
7.77
3.09
7.53
3.14
6.83
2.56
8.30
2.52
8.10
2.61
7.65
2.82
7.45
2.92
7.13
3.10
6.91
3.14
6.36
2.56
9.08
2.54
8.87
2.63
8.37
2.84
8.16
2.94
7.80
3.12
7.55
3.14
6.84
2.56
9.40
2.75
9.18
2.85
8.67
3.08
8.45
3.19
8.08
3.38
7.73
3.14
7.02
2.56
9.65
2.61
9.43
2.70
8.90
2.92
8.67
3.02
8.29
3.21
7.97
3.14
7.18
2.56
9.87
2.71
9.63
2.80
9.09
3.03
8.86
3.14
8.48
3.32
8.09
3.14
7.29
2.56

24C
TC
PI
kW
kW
9.37
2.49
9.16
2.57
8.66
2.78
8.45
2.87
8.10
3.04
7.88
3.14
7.10
2.56
7.38
1.97
7.21
2.04
6.82
2.20
6.66
2.28
6.38
2.41
6.21
2.50
6.02
2.56
7.95
2.37
7.77
2.45
7.35
2.65
7.17
2.74
6.87
2.90
6.69
3.00
6.20
2.56
8.96
2.38
8.76
2.46
8.29
2.66
8.09
2.75
7.75
2.91
7.54
3.01
6.88
2.56
9.40
2.56
9.18
2.65
8.69
2.86
8.48
2.96
8.12
3.13
7.85
3.14
7.09
2.56
8.62
2.57
8.42
2.65
7.97
2.87
7.77
2.97
7.45
3.14
7.21
3.14
6.60
2.56
9.43
2.59
9.22
2.67
8.72
2.89
8.51
2.99
8.15
3.16
7.87
3.14
7.10
2.56
9.77
2.80
9.55
2.90
9.03
3.13
8.81
3.24
8.44
3.43
8.04
3.14
7.28
2.56
10.03 2.66
9.80
2.75
9.27
2.97
9.04
3.07
8.67
3.25
8.30
3.14
7.45
2.56
10.25 2.76
10.02 2.85
9.48
3.08
9.24
3.19
8.86
3.37
8.42
3.14
7.56
2.56

SUPER MULTI NX E-Series Heat Pump

EDAU12-722

Combination
(Capacity)
2.0+2.0+2.0

2.0+2.0+2.5

2.0+2.0+3.5

2.0+2.0+5.0

2.0+2.0+6.0

2.0+2.5+2.5

2.0+2.5+3.5

2.0+2.5+5.0

2.0+2.5+6.0

2.0+3.5+3.5

Capacity Tables

Outdoor
air temp.
CDB
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0

SUPER MULTI NX E-Series Heat Pump

14C
TC
PI
kW
kW
6.49
1.60
6.31
1.66
5.89
1.81
5.71
1.87
5.41
1.99
5.23
2.07
5.05
2.15
6.89
1.79
6.70
1.86
6.25
2.02
6.06
2.10
5.74
2.23
5.55
2.31
5.36
2.40
7.25
2.03
7.05
2.10
6.58
2.29
6.38
2.37
6.04
2.53
5.84
2.62
5.55
2.56
7.95
2.21
7.73
2.29
7.21
2.49
6.99
2.59
6.62
2.75
6.40
2.86
5.96
2.56
8.20
2.32
7.97
2.40
7.44
2.61
7.21
2.71
6.83
2.88
6.60
2.99
6.09
2.56
7.14
1.96
6.94
2.03
6.48
2.20
6.28
2.29
5.95
2.43
5.75
2.53
5.52
2.56
7.62
2.20
7.41
2.28
6.92
2.48
6.71
2.58
6.35
2.74
6.14
2.84
5.74
2.56
7.98
2.21
7.76
2.29
7.24
2.49
7.02
2.59
6.65
2.75
6.43
2.86
5.98
2.56
8.42
2.47
8.19
2.56
7.64
2.79
7.41
2.89
7.02
3.08
6.77
3.14
6.21
2.56
7.93
2.46
7.71
2.55
7.19
2.77
6.97
2.87
6.61
3.06
6.38
3.14
5.91
2.56

16C
TC
PI
kW
kW
6.79
1.63
6.60
1.69
6.18
1.84
6.00
1.91
5.70
2.03
5.52
2.10
5.34
2.18
7.21
1.83
7.01
1.89
6.57
2.05
6.38
2.13
6.06
2.26
5.87
2.35
5.67
2.44
7.58
2.07
7.38
2.14
6.91
2.33
6.71
2.41
6.38
2.57
6.17
2.66
5.84
2.56
8.31
2.25
8.09
2.33
7.57
2.53
7.35
2.63
6.99
2.79
6.77
2.90
6.25
2.56
8.57
2.36
8.35
2.45
7.81
2.66
7.59
2.76
7.21
2.93
6.98
3.04
6.39
2.56
7.47
1.99
7.27
2.06
6.81
2.24
6.61
2.33
6.28
2.47
6.08
2.56
5.81
2.56
7.97
2.25
7.76
2.32
7.27
2.53
7.06
2.62
6.70
2.78
6.49
2.89
6.03
2.56
8.34
2.25
8.12
2.33
7.60
2.53
7.38
2.63
7.01
2.79
6.79
2.90
6.28
2.56
8.80
2.52
8.57
2.61
8.03
2.84
7.79
2.94
7.40
3.13
7.13
3.14
6.51
2.56
8.29
2.51
8.07
2.59
7.56
2.82
7.34
2.92
6.97
3.11
6.73
3.14
6.20
2.56

Indoor air temp.:CWB


18C
19C
TC
PI
TC
PI
kW
kW
kW
kW
7.08
1.66
7.23
1.68
6.90
1.72
7.05
1.74
6.48
1.87
6.63
1.88
6.30
1.94
6.45
1.95
6.00
2.06
6.15
2.07
5.82
2.13
5.97
2.15
5.64
2.21
5.79
2.23
7.52
1.86
7.68
1.88
7.33
1.93
7.49
1.94
6.88
2.09
7.04
2.11
6.69
2.16
6.85
2.18
6.37
2.30
6.53
2.32
6.18
2.38
6.34
2.40
5.99
2.47
6.15
2.49
7.92
2.11
8.08
2.13
7.72
2.18
7.88
2.20
7.25
2.37
7.41
2.39
7.04
2.45
7.21
2.47
6.71
2.60
6.87
2.62
6.51
2.70
6.67
2.72
6.13
2.56
6.27
2.56
8.67
2.30
8.86
2.32
8.45
2.38
8.64
2.40
7.94
2.58
8.12
2.60
7.72
2.67
7.90
2.69
7.35
2.84
7.53
2.86
7.13
2.94
7.31
2.96
6.55
2.56
6.69
2.56
8.95
2.41
9.14
2.43
8.72
2.49
8.91
2.51
8.19
2.70
8.38
2.72
7.96
2.80
8.15
2.82
7.58
2.97
7.77
3.00
7.36
3.08
7.54
3.11
6.68
2.56
6.82
2.56
7.80
2.03
7.96
2.05
7.60
2.10
7.76
2.12
7.13
2.28
7.30
2.30
6.94
2.36
7.10
2.38
6.61
2.51
6.77
2.53
6.41
2.60
6.57
2.62
6.10
2.56
6.24
2.56
8.32
2.29
8.50
2.31
8.11
2.37
8.29
2.39
7.62
2.57
7.79
2.59
7.41
2.66
7.58
2.68
7.05
2.83
7.23
2.85
6.84
2.93
7.02
2.95
6.32
2.56
6.46
2.56
8.71
2.30
8.89
2.32
8.49
2.38
8.67
2.40
7.97
2.58
8.15
2.60
7.75
2.67
7.93
2.69
7.38
2.84
7.56
2.86
7.16
2.94
7.34
2.96
6.57
2.56
6.71
2.56
9.19
2.57
9.38
2.59
8.96
2.66
9.15
2.68
8.41
2.88
8.60
2.91
8.18
2.99
8.37
3.01
7.79
3.17
7.98
3.20
7.49
3.14
7.67
3.14
6.79
2.56
6.94
2.56
8.65
2.55
8.83
2.58
8.43
2.64
8.61
2.67
7.92
2.87
8.10
2.89
7.70
2.97
7.88
2.99
7.33
3.15
7.51
3.18
7.07
3.14
7.24
3.14
6.47
2.56
6.61
2.56

22C
TC
PI
kW
kW
7.68
1.73
7.50
1.78
7.08
1.93
6.90
2.00
6.60
2.12
6.42
2.19
6.24
2.27
8.15
1.93
7.96
2.00
7.51
2.16
7.32
2.23
7.00
2.37
6.81
2.45
6.62
2.54
8.58
2.19
8.38
2.26
7.91
2.45
7.71
2.53
7.37
2.68
7.17
2.78
6.68
2.56
9.40
2.38
9.18
2.46
8.67
2.66
8.45
2.76
8.08
2.92
7.86
3.03
7.11
2.56
9.70
2.50
9.47
2.58
8.94
2.79
8.71
2.89
8.33
3.06
8.08
3.14
7.25
2.56
8.45
2.11
8.25
2.18
7.79
2.36
7.59
2.44
7.26
2.59
7.06
2.68
6.66
2.56
9.02
2.37
8.81
2.45
8.32
2.65
8.10
2.75
7.75
2.91
7.54
3.02
6.87
2.56
9.44
2.38
9.22
2.46
8.70
2.66
8.48
2.76
8.11
2.92
7.89
3.03
7.14
2.56
9.96
2.67
9.73
2.76
9.18
2.98
8.95
3.09
8.56
3.27
8.18
3.14
7.35
2.56
9.38
2.65
9.16
2.74
8.64
2.96
8.42
3.06
8.06
3.25
7.74
3.14
7.01
2.56

24C
TC
PI
kW
kW
7.97
1.76
7.79
1.82
7.37
1.96
7.19
2.03
6.89
2.15
6.71
2.23
6.53
2.30
8.47
1.97
8.28
2.03
7.83
2.19
7.64
2.27
7.32
2.40
7.13
2.49
6.91
2.56
8.91
2.23
8.71
2.30
8.24
2.49
8.04
2.57
7.70
2.72
7.50
2.82
6.95
2.56
9.77
2.43
9.55
2.51
9.03
2.71
8.81
2.80
8.44
2.97
8.22
3.07
7.39
2.56
10.08 2.54
9.85
2.63
9.32
2.84
9.09
2.94
8.71
3.11
8.42
3.14
7.52
2.56
8.78
2.15
8.58
2.22
8.12
2.40
7.92
2.48
7.59
2.62
7.39
2.72
6.93
2.56
9.37
2.42
9.16
2.50
8.66
2.70
8.45
2.79
8.10
2.95
7.89
3.06
7.13
2.56
9.80
2.43
9.58
2.51
9.06
2.71
8.84
2.80
8.47
2.97
8.25
3.07
7.41
2.56
10.35 2.71
10.11 2.80
9.57
3.03
9.33
3.13
8.94
3.32
8.52
3.14
7.62
2.56
9.74
2.70
9.52
2.78
9.01
3.01
8.79
3.11
8.42
3.30
8.06
3.14
7.27
2.56

79

Capacity Tables

Combination
(Capacity)
2.0+3.5+5.0

2.5+2.5+2.5

2.5+2.5+3.5

2.5+2.5+5.0

2.5+2.5+6.0

2.5+3.5+3.5

2.5+3.5+5.0

3.5+3.5+3.5

EDAU12-722

Outdoor
air temp.
CDB
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0

Symbols

14C
TC
PI
kW
kW
8.42
2.56
8.19
2.66
7.64
2.89
7.41
3.00
7.02
3.19
6.75
3.14
6.22
2.56
7.49
2.12
7.29
2.20
6.80
2.39
6.59
2.48
6.25
2.64
6.04
2.74
5.68
2.56
7.84
2.35
7.62
2.43
7.11
2.65
6.89
2.75
6.53
2.92
6.31
3.04
5.86
2.56
8.32
2.43
8.09
2.52
7.55
2.74
7.32
2.84
6.93
3.03
6.70
3.14
6.15
2.56
8.58
2.61
8.34
2.71
7.79
2.95
7.55
3.06
7.15
3.25
6.87
3.14
6.32
2.56
8.16
2.63
7.93
2.72
7.40
2.96
7.18
3.08
6.80
3.27
6.56
3.14
6.09
2.56
8.58
2.67
8.34
2.77
7.79
3.01
7.55
3.12
7.15
3.32
6.87
3.14
6.33
2.56
8.49
2.74
8.25
2.83
7.70
3.08
7.47
3.20
7.07
3.40
6.82
3.14
6.31
2.56

16C
TC
PI
kW
kW
8.80
2.61
8.57
2.71
8.03
2.94
7.79
3.05
7.40
3.24
7.11
3.14
6.51
2.56
7.84
2.16
7.63
2.24
7.14
2.43
6.94
2.52
6.59
2.68
6.38
2.78
5.97
2.56
8.19
2.40
7.98
2.48
7.47
2.70
7.25
2.79
6.89
2.97
6.67
3.08
6.14
2.56
8.70
2.48
8.47
2.57
7.93
2.79
7.70
2.89
7.31
3.07
7.06
3.14
6.45
2.56
8.97
2.66
8.73
2.76
8.18
3.00
7.94
3.11
7.54
3.30
7.23
3.14
6.61
2.56
8.53
2.68
8.30
2.78
7.78
3.02
7.55
3.13
7.17
3.32
6.90
3.14
6.37
2.56
8.97
2.72
8.73
2.82
8.18
3.06
7.94
3.18
7.54
3.38
7.23
3.14
6.62
2.56
8.88
2.79
8.64
2.89
8.09
3.14
7.86
3.25
7.46
3.46
7.17
3.14
6.59
2.56

Indoor air temp.:CWB


18C
19C
TC
PI
TC
PI
kW
kW
kW
kW
9.19
2.66
9.38
2.69
8.96
2.76
9.15
2.78
8.41
2.99
8.60
3.01
8.18
3.10
8.37
3.12
7.79
3.29
7.98
3.31
7.46
3.14
7.63
3.14
6.79
2.56
6.93
2.56
8.18
2.20
8.35
2.22
7.97
2.28
8.14
2.30
7.49
2.47
7.66
2.49
7.28
2.56
7.45
2.58
6.93
2.72
7.10
2.74
6.72
2.82
6.89
2.84
6.26
2.56
6.40
2.56
8.55
2.44
8.73
2.46
8.34
2.53
8.52
2.55
7.83
2.74
8.01
2.76
7.61
2.84
7.79
2.86
7.25
3.02
7.43
3.04
7.03
3.13
7.20
3.14
6.42
2.56
6.56
2.56
9.08
2.53
9.27
2.55
8.85
2.61
9.04
2.64
8.31
2.84
8.50
2.86
8.08
2.94
8.27
2.96
7.69
3.12
7.88
3.14
7.42
3.14
7.60
3.14
6.73
2.56
6.88
2.56
9.37
2.72
9.56
2.74
9.13
2.81
9.32
2.83
8.57
3.05
8.77
3.07
8.33
3.16
8.53
3.18
7.94
3.35
8.13
3.38
7.58
3.14
7.76
3.14
6.90
2.56
7.04
2.56
8.91
2.73
9.09
2.76
8.68
2.83
8.87
2.85
8.15
3.07
8.34
3.09
7.92
3.18
8.11
3.20
7.55
3.37
7.73
3.40
7.24
3.14
7.41
3.14
6.64
2.56
6.77
2.56
9.37
2.77
9.56
2.80
9.13
2.87
9.32
2.90
8.57
3.11
8.77
3.14
8.33
3.23
8.53
3.25
7.94
3.43
8.13
3.45
7.58
3.14
7.75
3.14
6.90
2.56
7.04
2.56
9.27
2.84
9.46
2.87
9.03
2.94
9.23
2.97
8.48
3.19
8.68
3.22
8.25
3.31
8.44
3.33
7.85
3.51
8.05
3.54
7.51
3.14
7.68
3.14
6.87
2.56
7.00
2.56

22C
TC
PI
kW
kW
9.96
2.76
9.73
2.86
9.18
3.09
8.95
3.20
8.56
3.39
8.14
3.14
7.34
2.56
8.87
2.29
8.66
2.36
8.17
2.56
7.96
2.64
7.62
2.80
7.41
2.90
6.81
2.56
9.27
2.53
9.05
2.62
8.55
2.83
8.33
2.93
7.97
3.11
7.71
3.14
6.97
2.56
9.84
2.62
9.61
2.71
9.07
2.93
8.84
3.03
8.46
3.22
8.11
3.14
7.29
2.56
10.15 2.82
9.91
2.91
9.36
3.15
9.12
3.26
8.72
3.45
8.27
3.14
7.45
2.56
9.65
2.83
9.43
2.93
8.90
3.17
8.67
3.28
8.29
3.48
7.90
3.14
7.17
2.56
10.15 2.88
9.91
2.97
9.36
3.22
9.12
3.33
8.72
3.53
8.26
3.14
7.45
2.56
10.05 2.95
9.81
3.05
9.26
3.30
9.02
3.41
8.63
3.62
8.17
3.14
7.40
2.56

24C
TC
PI
kW
kW
10.35 2.81
10.11 2.91
9.57
3.14
9.33
3.25
8.94
3.44
8.47
3.14
7.61
2.56
9.21
2.33
9.00
2.40
8.52
2.60
8.31
2.69
7.96
2.84
7.75
2.94
7.08
2.56
9.63
2.58
9.41
2.66
8.90
2.88
8.69
2.98
8.32
3.15
8.03
3.14
7.23
2.56
10.22 2.67
9.99
2.76
9.45
2.98
9.22
3.08
8.84
3.26
8.45
3.14
7.56
2.56
10.55 2.87
10.31 2.96
9.75
3.20
9.51
3.31
9.12
3.51
8.60
3.14
7.72
2.56
10.03 2.89
9.80
2.98
9.27
3.22
9.04
3.33
8.67
3.53
8.22
3.14
7.43
2.56
10.55 2.93
10.31 3.03
9.75
3.27
9.51
3.38
9.12
3.58
8.58
3.14
7.72
2.56
10.43 3.00
10.20 3.10
9.65
3.35
9.41
3.47
9.02
3.67
8.50
3.14
7.66
2.56

NOTE:

TC

: Total capacity

(kW)

PI

: Power input

(kW)

Capacities are based on the following conditions.


Corresponding refrigerant piping length : 7.5m
Level difference : 0m
3D055087
3D055088
3D055089
3D055090

80

SUPER MULTI NX E-Series Heat Pump

EDAU12-722

Capacity Tables

[Heating Capacity 50Hz 230V]


Combination
(Capacity)
2.0

2.5

3.5

5.0

6.0

2.0+2.0

2.0+2.5

2.0+3.5

2.0+5.0

2.0+6.0

2.5+2.5

Indoor
air temp.
CDB
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0

SUPER MULTI NX E-Series Heat Pump

-15C
TC
PI
kW
kW
2.15 1.00
2.09 1.01
2.04 1.02
2.01 1.02
1.99 1.03
1.93 1.04
2.27 1.08
2.22 1.09
2.16 1.10
2.13 1.11
2.10 1.11
2.05 1.12
2.47 1.26
2.41 1.28
2.35 1.29
2.32 1.30
2.29 1.30
2.23 1.32
4.44 2.19
4.33 2.22
4.22 2.24
4.16 2.25
4.11 2.27
3.99 2.29
4.71 2.19
4.59 2.22
4.47 2.24
4.42 2.25
4.36 2.27
4.24 2.29
4.23 1.78
4.13 1.80
4.02 1.82
3.97 1.83
3.92 1.84
3.81 1.86
4.33 1.85
4.22 1.87
4.11 1.89
4.06 1.90
4.00 1.91
3.90 1.94
4.62 2.08
4.51 2.10
4.39 2.13
4.33 2.14
4.27 2.15
4.16 2.17
5.60 2.34
5.46 2.36
5.32 2.39
5.25 2.40
5.18 2.42
5.04 2.44
5.71 2.36
5.57 2.39
5.43 2.41
5.35 2.43
5.28 2.44
5.14 2.47
4.50 2.02
4.39 2.05
4.28 2.07
4.22 2.08
4.17 2.09
4.05 2.11

-10C
TC
PI
kW
kW
2.59 1.05
2.53 1.06
2.48 1.07
2.45 1.07
2.42 1.08
2.37 1.09
2.74 1.13
2.68 1.14
2.62 1.15
2.60 1.16
2.57 1.17
2.51 1.18
2.98 1.33
2.92 1.34
2.85 1.35
2.82 1.36
2.79 1.37
2.73 1.38
5.34 2.30
5.23 2.33
5.12 2.35
5.07 2.37
5.01 2.38
4.90 2.40
5.67 2.30
5.55 2.33
5.44 2.35
5.38 2.37
5.32 2.38
5.20 2.40
5.10 1.87
4.99 1.89
4.89 1.91
4.83 1.92
4.78 1.93
4.67 1.95
5.21 1.95
5.10 1.97
4.99 1.99
4.94 2.00
4.89 2.01
4.78 2.03
5.56 2.19
5.45 2.21
5.33 2.23
5.28 2.24
5.22 2.25
5.10 2.28
6.74 2.46
6.60 2.48
6.46 2.51
6.39 2.52
6.32 2.54
6.18 2.56
6.88 2.48
6.73 2.51
6.59 2.54
6.52 2.55
6.45 2.56
6.31 2.59
5.42 2.13
5.31 2.15
5.20 2.17
5.14 2.18
5.09 2.19
4.97 2.22

Outdoor air temp.:CWB


-5C
0C
6C
TC
PI
TC
PI
TC
PI
kW
kW
kW
kW
kW
kW
3.02 1.10 3.46 1.15 3.99 1.21
2.97 1.11 3.41 1.16 3.93 1.22
2.92 1.12 3.35 1.17 3.88 1.23
2.89 1.12 3.33 1.17 3.85 1.24
2.86 1.13 3.30 1.18 3.83 1.24
2.81 1.14 3.25 1.19 3.77 1.25
3.20 1.19 3.67 1.24 4.22 1.31
3.15 1.20 3.61 1.25 4.17 1.32
3.09 1.21 3.55 1.26 4.11 1.33
3.06 1.22 3.52 1.27 4.08 1.34
3.03 1.22 3.50 1.28 4.05 1.34
2.98 1.23 3.44 1.29 4.00 1.35
3.48 1.39 3.99 1.45 4.59 1.53
3.42 1.40 3.93 1.47 4.53 1.55
3.36 1.42 3.86 1.48 4.47 1.56
3.33 1.43 3.83 1.49 4.44 1.57
3.30 1.43 3.80 1.50 4.41 1.57
3.24 1.45 3.74 1.51 4.35 1.59
6.25 2.42 7.15 2.53 8.24 2.66
6.14 2.44 7.04 2.55 8.13 2.69
6.03 2.46 6.93 2.58 8.02 2.71
5.97 2.48 6.88 2.59 7.96 2.72
5.92 2.49 6.82 2.60 7.91 2.73
5.81 2.51 6.71 2.62 7.69 2.68
6.63 2.42 7.59 2.53 8.74 2.66
6.51 2.44 7.47 2.55 8.63 2.69
6.40 2.46 7.36 2.58 8.51 2.71
6.34 2.48 7.30 2.59 8.45 2.72
6.28 2.49 7.24 2.60 8.39 2.73
6.16 2.51 7.12 2.62 8.28 2.76
5.96 1.96 6.82 2.05 7.86 2.16
5.86 1.98 6.72 2.07 7.76 2.18
5.75 2.00 6.61 2.09 7.65 2.20
5.70 2.01 6.56 2.10 7.60 2.21
5.64 2.02 6.51 2.11 7.54 2.22
5.54 2.04 6.40 2.13 7.44 2.24
6.09 2.04 6.98 2.14 8.04 2.25
5.99 2.06 6.87 2.16 7.93 2.27
5.88 2.08 6.76 2.18 7.82 2.29
5.82 2.09 6.71 2.19 7.77 2.30
5.77 2.10 6.65 2.20 7.71 2.31
5.66 2.12 6.54 2.22 7.60 2.33
6.51 2.29 7.45 2.40 8.58 2.52
6.39 2.31 7.33 2.42 8.47 2.55
6.28 2.34 7.22 2.44 8.35 2.57
6.22 2.35 7.16 2.45 8.29 2.58
6.16 2.36 7.10 2.47 8.23 2.59
6.05 2.38 6.99 2.49 8.12 2.62
7.89 2.58 9.03 2.70 10.40 2.84
7.75 2.60 8.89 2.72 10.26 2.86
7.61 2.63 8.75 2.75 10.12 2.89
7.54 2.64 8.68 2.76 10.05 2.90
7.47 2.65 8.61 2.77 9.98 2.92
7.33 2.68 8.47 2.80 9.84 2.94
8.04 2.60 9.21 2.72 10.60 2.87
7.90 2.63 9.06 2.75 10.46 2.89
7.76 2.66 8.92 2.78 10.32 2.92
7.69 2.67 8.85 2.79 10.25 2.93
7.61 2.68 8.78 2.80 10.18 2.95
7.47 2.71 8.64 2.83 10.04 2.97
6.34 2.23 7.26 2.33 8.36 2.45
6.23 2.25 7.15 2.35 8.25 2.48
6.12 2.27 7.04 2.38 8.14 2.50
6.06 2.28 6.98 2.39 8.08 2.51
6.01 2.30 6.92 2.40 8.03 2.52
5.89 2.32 6.81 2.42 7.92 2.55

10C
TC
PI
kW
kW
4.34 1.25
4.28 1.26
4.23 1.27
4.20 1.28
4.18 1.28
4.12 1.29
4.59 1.35
4.54 1.36
4.48 1.37
4.45 1.38
4.42 1.39
4.37 1.40
5.00 1.58
4.94 1.60
4.87 1.61
4.84 1.62
4.81 1.63
4.75 1.64
8.97 2.75
8.86 2.77
8.61 2.71
8.38 2.61
8.15 2.51
7.69 2.32
9.51 2.75
9.40 2.77
9.28 2.80
9.06 2.71
8.81 2.61
8.32 2.41
8.55 2.23
8.45 2.25
8.34 2.27
8.29 2.28
8.24 2.29
8.13 2.31
8.74 2.32
8.63 2.34
8.53 2.37
8.47 2.38
8.42 2.39
8.31 2.41
9.33 2.61
9.22 2.63
9.10 2.65
9.05 2.67
8.99 2.68
8.87 2.70
11.31 2.93
11.17 2.96
11.03 2.99
10.96 3.00
10.89 3.01
10.75 3.04
11.54 2.96
11.39 2.99
11.25 3.02
11.18 3.03
11.11 3.04
10.97 3.07
9.10 2.54
8.99 2.56
8.88 2.58
8.82 2.59
8.76 2.60
8.65 2.63

15C
TC
PI
kW
kW
4.78 1.30
4.72 1.31
4.67 1.32
4.64 1.33
4.62 1.33
4.56 1.34
5.06 1.40
5.00 1.42
4.95 1.43
4.92 1.43
4.89 1.44
4.83 1.45
5.50 1.65
5.44 1.66
5.38 1.68
5.35 1.68
5.32 1.69
5.03 1.58
9.53 2.66
9.07 2.49
8.61 2.32
8.38 2.24
8.15 2.16
7.69 2.00
10.30 2.76
9.81 2.58
9.31 2.40
9.06 2.31
8.81 2.23
8.32 2.06
9.42 2.32
9.31 2.34
9.20 2.36
9.15 2.37
9.10 2.38
8.99 2.40
9.63 2.42
9.52 2.44
9.41 2.46
9.36 2.47
9.30 2.48
9.19 2.50
10.28 2.71
10.16 2.74
10.05 2.76
9.99 2.77
9.93 2.78
9.82 2.81
12.46 3.05
12.32 3.08
12.18 3.10
12.11 3.12
12.04 3.13
11.90 3.16
12.70 3.08
12.56 3.11
12.42 3.14
12.35 3.15
12.28 3.16
12.13 3.19
10.02 2.64
9.91 2.66
9.79 2.69
9.74 2.70
9.68 2.71
9.57 2.73

81

Capacity Tables

Combination
(Capacity)
2.5+3.5

2.5+5.0

2.5+6.0

3.5+3.5

3.5+5.0

3.5+6.0

5.0+5.0

5.0+6.0

2.0+2.0+2.0

2.0+2.0+2.5

2.0+2.0+3.5

82

EDAU12-722

Indoor
air temp.
CDB
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0

-15C
TC
PI
kW
kW
4.77 2.27
4.65 2.29
4.53 2.32
4.47 2.33
4.41 2.34
4.29 2.37
5.66 2.37
5.52 2.40
5.38 2.42
5.31 2.44
5.24 2.45
5.10 2.48
5.75 2.37
5.61 2.40
5.47 2.42
5.40 2.44
5.32 2.45
5.18 2.48
4.96 2.45
4.84 2.48
4.72 2.51
4.65 2.52
4.59 2.53
4.47 2.56
5.76 2.44
5.62 2.46
5.47 2.49
5.40 2.50
5.33 2.52
5.19 2.54
5.84 2.36
5.70 2.39
5.55 2.41
5.48 2.43
5.41 2.44
5.26 2.47
5.87 2.27
5.72 2.29
5.58 2.32
5.50 2.33
5.43 2.34
5.29 2.37
5.89 2.22
5.74 2.24
5.59 2.27
5.52 2.28
5.45 2.29
5.30 2.32
5.55 2.14
5.41 2.16
5.27 2.18
5.20 2.20
5.13 2.21
5.00 2.23
5.60 2.17
5.46 2.19
5.32 2.22
5.25 2.23
5.18 2.24
5.04 2.26
5.64 2.27
5.50 2.29
5.36 2.32
5.29 2.33
5.22 2.34
5.08 2.37

-10C
TC
PI
kW
kW
5.74 2.38
5.62 2.41
5.51 2.43
5.45 2.44
5.39 2.46
5.27 2.48
6.82 2.49
6.67 2.52
6.53 2.54
6.46 2.56
6.39 2.57
6.25 2.60
6.93 2.49
6.79 2.52
6.64 2.54
6.57 2.56
6.50 2.57
6.35 2.60
5.98 2.58
5.85 2.60
5.73 2.63
5.67 2.64
5.60 2.66
5.48 2.69
6.94 2.56
6.79 2.59
6.65 2.61
6.58 2.63
6.50 2.64
6.36 2.67
7.04 2.48
6.89 2.51
6.74 2.54
6.67 2.55
6.60 2.56
6.45 2.59
7.07 2.38
6.92 2.41
6.78 2.43
6.70 2.44
6.63 2.46
6.48 2.48
7.09 2.33
6.94 2.35
6.80 2.38
6.72 2.39
6.65 2.40
6.50 2.43
6.68 2.24
6.54 2.27
6.41 2.29
6.34 2.30
6.27 2.32
6.13 2.34
6.74 2.28
6.60 2.30
6.46 2.33
6.39 2.34
6.32 2.35
6.18 2.38
6.80 2.38
6.66 2.41
6.51 2.43
6.44 2.44
6.37 2.46
6.23 2.48

Outdoor air temp.:CWB


-5C
0C
6C
TC
PI
TC
PI
TC
PI
kW
kW
kW
kW
kW
kW
6.72 2.50 7.69 2.61 8.86 2.75
6.60 2.52 7.57 2.64 8.74 2.77
6.48 2.55 7.45 2.66 8.62 2.80
6.42 2.56 7.39 2.67 8.56 2.81
6.36 2.57 7.33 2.69 8.50 2.83
6.24 2.60 7.21 2.71 8.38 2.85
7.97 2.61 9.13 2.73 10.51 2.88
7.83 2.64 8.99 2.76 10.37 2.90
7.69 2.66 8.84 2.79 10.23 2.93
7.62 2.68 8.77 2.80 10.16 2.94
7.55 2.69 8.70 2.81 10.09 2.96
7.41 2.72 8.56 2.84 9.95 2.98
8.10 2.61 9.28 2.73 10.69 2.88
7.96 2.64 9.13 2.76 10.54 2.90
7.82 2.66 8.99 2.79 10.40 2.93
7.74 2.68 8.92 2.80 10.33 2.94
7.67 2.69 8.85 2.81 10.26 2.96
7.53 2.72 8.70 2.84 10.11 2.98
6.99 2.70 8.00 2.83 9.22 2.98
6.87 2.73 7.88 2.85 9.09 3.00
6.74 2.76 7.75 2.88 8.97 3.03
6.68 2.77 7.69 2.89 8.91 3.04
6.62 2.78 7.63 2.91 8.85 3.06
6.49 2.81 7.51 2.93 8.72 3.08
8.11 2.68 9.29 2.81 10.70 2.96
7.97 2.71 9.14 2.83 10.55 2.98
7.82 2.74 9.00 2.86 10.41 3.01
7.75 2.75 8.93 2.87 10.34 3.02
7.68 2.76 8.86 2.89 10.27 3.04
7.54 2.79 8.71 2.92 10.12 3.06
8.23 2.60 9.42 2.72 10.85 2.87
8.08 2.63 9.27 2.75 10.71 2.89
7.94 2.66 9.13 2.78 10.56 2.92
7.86 2.67 9.06 2.79 10.49 2.93
7.79 2.68 8.98 2.80 10.41 2.95
7.65 2.71 8.84 2.83 10.27 2.97
8.27 2.50 9.47 2.61 10.90 2.75
8.12 2.52 9.32 2.64 10.76 2.77
7.97 2.55 9.17 2.66 10.61 2.80
7.90 2.56 9.10 2.67 10.54 2.81
7.83 2.57 9.03 2.69 10.46 2.83
7.68 2.60 8.88 2.71 10.32 2.85
8.29 2.44 9.49 2.56 10.93 2.69
8.14 2.47 9.35 2.58 10.79 2.72
8.00 2.49 9.20 2.60 10.64 2.74
7.92 2.50 9.12 2.62 10.57 2.75
7.85 2.52 9.05 2.63 10.49 2.76
7.70 2.54 8.90 2.65 10.35 2.79
7.82 2.35 8.95 2.46 10.31 2.59
7.68 2.38 8.81 2.49 10.17 2.62
7.54 2.40 8.67 2.51 10.03 2.64
7.47 2.41 8.60 2.52 9.96 2.65
7.40 2.42 8.53 2.53 9.89 2.66
7.26 2.45 8.39 2.56 9.75 2.69
7.89 2.39 9.03 2.50 10.40 2.63
7.75 2.41 8.89 2.52 10.26 2.66
7.61 2.44 8.75 2.55 10.12 2.68
7.54 2.45 8.68 2.56 10.05 2.69
7.47 2.46 8.61 2.57 9.98 2.70
7.33 2.49 8.47 2.60 9.84 2.73
7.95 2.50 9.10 2.61 10.48 2.75
7.81 2.52 8.96 2.64 10.34 2.77
7.67 2.55 8.82 2.66 10.20 2.80
7.60 2.56 8.75 2.67 10.13 2.81
7.53 2.57 8.68 2.69 10.06 2.83
7.38 2.60 8.54 2.71 9.92 2.85

10C
TC
PI
kW
kW
9.64 2.84
9.52 2.87
9.40 2.89
9.34 2.90
9.28 2.92
9.16 2.94
11.44 2.97
11.30 3.00
11.15 3.03
11.08 3.04
11.01 3.05
10.87 3.08
11.63 2.97
11.48 3.00
11.34 3.03
11.27 3.04
11.20 3.05
11.05 3.08
10.03 3.08
9.90 3.10
9.78 3.13
9.72 3.14
9.66 3.16
9.53 3.18
11.64 3.05
11.49 3.08
11.35 3.11
11.28 3.12
11.21 3.14
11.06 3.16
11.81 2.96
11.66 2.99
11.51 3.02
11.44 3.03
11.37 3.04
11.22 3.07
11.86 2.84
11.71 2.87
11.57 2.89
11.50 2.90
11.42 2.92
11.28 2.94
11.89 2.78
11.75 2.81
11.60 2.83
11.53 2.84
11.45 2.85
11.31 2.88
11.21 2.68
11.07 2.70
10.94 2.73
10.87 2.74
10.80 2.75
10.66 2.77
11.31 2.72
11.17 2.74
11.03 2.77
10.96 2.78
10.89 2.79
10.75 2.82
11.40 2.84
11.26 2.87
11.12 2.89
11.05 2.90
10.98 2.92
10.84 2.94

15C
TC
PI
kW
kW
10.61 2.96
10.49 2.98
10.37 3.01
10.31 3.02
10.25 3.03
9.90 2.91
12.59 3.09
12.45 3.12
12.31 3.15
12.24 3.16
12.17 3.17
12.03 3.20
12.80 3.09
12.66 3.12
12.51 3.15
12.44 3.16
12.37 3.17
12.23 3.20
11.04 3.20
10.92 3.23
10.79 3.25
10.73 3.27
10.66 3.27
10.06 2.98
12.81 3.18
12.67 3.21
12.53 3.23
12.45 3.25
12.38 3.26
12.24 3.29
13.00 3.08
12.85 3.11
12.71 3.14
12.63 3.15
12.56 3.16
12.41 3.19
13.06 2.96
12.91 2.98
12.77 3.01
12.69 3.02
12.62 3.03
12.47 3.06
13.10 2.89
12.95 2.92
12.80 2.94
12.73 2.96
12.66 2.97
12.51 2.99
12.35 2.79
12.21 2.81
12.07 2.84
12.00 2.85
11.93 2.86
11.79 2.88
12.46 2.83
12.32 2.85
12.18 2.88
12.11 2.89
12.04 2.90
11.90 2.93
12.55 2.96
12.41 2.98
12.27 3.01
12.20 3.02
12.13 3.03
11.99 3.06

SUPER MULTI NX E-Series Heat Pump

EDAU12-722

Combination
(Capacity)
2.0+2.0+5.0

2.0+2.0+6.0

2.0+2.5+2.5

2.0+2.5+3.5

2.0+2.5+5.0

2.0+2.5+6.0

2.0+3.5+3.5

2.0+3.5+5.0

2.5+2.5+2.5

2.5+2.5+3.5

2.5+2.5+5.0

Capacity Tables

Indoor
air temp.
CDB
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0

SUPER MULTI NX E-Series Heat Pump

-15C
TC
PI
kW
kW
5.79 2.12
5.65 2.14
5.50 2.17
5.43 2.18
5.36 2.19
5.22 2.21
5.87 2.11
5.72 2.14
5.57 2.16
5.50 2.17
5.43 2.18
5.28 2.21
5.60 2.21
5.46 2.23
5.32 2.26
5.25 2.27
5.18 2.28
5.04 2.31
5.64 2.27
5.50 2.29
5.36 2.32
5.29 2.33
5.22 2.34
5.08 2.37
5.87 2.14
5.72 2.17
5.58 2.19
5.50 2.20
5.43 2.22
5.29 2.24
5.89 2.08
5.74 2.10
5.59 2.13
5.52 2.14
5.45 2.15
5.30 2.17
5.76 2.30
5.62 2.32
5.47 2.35
5.40 2.36
5.33 2.37
5.19 2.40
5.89 2.20
5.74 2.23
5.59 2.25
5.52 2.26
5.45 2.27
5.30 2.30
5.66 2.27
5.52 2.29
5.38 2.32
5.31 2.33
5.24 2.34
5.10 2.37
5.76 2.33
5.62 2.36
5.47 2.38
5.40 2.39
5.33 2.41
5.19 2.43
5.87 2.17
5.72 2.19
5.58 2.22
5.50 2.23
5.43 2.24
5.29 2.26

-10C
TC
PI
kW
kW
6.98 2.23
6.83 2.25
6.69 2.27
6.61 2.29
6.54 2.30
6.40 2.32
7.06 2.22
6.92 2.24
6.77 2.27
6.70 2.28
6.62 2.29
6.48 2.31
6.74 2.32
6.60 2.35
6.46 2.37
6.39 2.38
6.32 2.39
6.18 2.42
6.80 2.38
6.66 2.41
6.51 2.43
6.44 2.44
6.37 2.46
6.23 2.48
7.07 2.25
6.92 2.28
6.78 2.30
6.70 2.31
6.63 2.32
6.48 2.35
7.09 2.19
6.94 2.21
6.80 2.23
6.72 2.24
6.65 2.25
6.50 2.28
6.94 2.41
6.79 2.44
6.65 2.47
6.58 2.48
6.50 2.49
6.36 2.52
7.09 2.31
6.94 2.34
6.80 2.36
6.72 2.37
6.65 2.39
6.50 2.41
6.82 2.38
6.67 2.41
6.53 2.43
6.46 2.44
6.39 2.46
6.25 2.48
6.94 2.45
6.79 2.47
6.65 2.50
6.58 2.51
6.50 2.53
6.36 2.55
7.07 2.28
6.92 2.30
6.78 2.33
6.70 2.34
6.63 2.35
6.48 2.38

Outdoor air temp.:CWB


-5C
0C
6C
TC
PI
TC
PI
TC
PI
kW
kW
kW
kW
kW
kW
8.16 2.34 9.34 2.44 10.76 2.57
8.01 2.36 9.20 2.47 10.61 2.60
7.87 2.38 9.05 2.49 10.47 2.62
7.80 2.39 8.98 2.50 10.40 2.63
7.72 2.41 8.91 2.51 10.33 2.64
7.58 2.43 8.76 2.54 10.18 2.67
8.26 2.33 9.46 2.43 10.89 2.56
8.11 2.35 9.31 2.46 10.75 2.59
7.97 2.37 9.16 2.48 10.60 2.61
7.89 2.39 9.09 2.49 10.53 2.62
7.82 2.40 9.02 2.50 10.45 2.63
7.67 2.42 8.87 2.53 10.31 2.66
7.89 2.43 9.03 2.55 10.40 2.68
7.75 2.46 8.89 2.57 10.26 2.71
7.61 2.48 8.75 2.60 10.12 2.73
7.54 2.49 8.68 2.61 10.05 2.74
7.47 2.51 8.61 2.62 9.98 2.75
7.33 2.53 8.47 2.64 9.84 2.78
7.95 2.50 9.10 2.61 10.48 2.75
7.81 2.52 8.96 2.64 10.34 2.77
7.67 2.55 8.82 2.66 10.20 2.80
7.60 2.56 8.75 2.67 10.13 2.81
7.53 2.57 8.68 2.69 10.06 2.83
7.38 2.60 8.54 2.71 9.92 2.85
8.27 2.36 9.47 2.47 10.90 2.60
8.12 2.39 9.32 2.50 10.76 2.63
7.97 2.41 9.17 2.52 10.61 2.65
7.90 2.42 9.10 2.53 10.54 2.66
7.83 2.43 9.03 2.54 10.46 2.67
7.68 2.46 8.88 2.57 10.32 2.70
8.29 2.29 9.49 2.40 10.93 2.52
8.14 2.31 9.35 2.42 10.79 2.55
8.00 2.34 9.20 2.44 10.64 2.57
7.92 2.35 9.12 2.45 10.57 2.58
7.85 2.36 9.05 2.47 10.49 2.59
7.70 2.38 8.90 2.49 10.35 2.62
8.11 2.53 9.29 2.65 10.70 2.79
7.97 2.56 9.14 2.67 10.55 2.81
7.82 2.58 9.00 2.70 10.41 2.84
7.75 2.60 8.93 2.71 10.34 2.85
7.68 2.61 8.86 2.73 10.27 2.87
7.54 2.63 8.71 2.75 10.12 2.89
8.29 2.42 9.49 2.54 10.93 2.67
8.14 2.45 9.35 2.56 10.79 2.70
8.00 2.47 9.20 2.59 10.64 2.72
7.92 2.49 9.12 2.60 10.57 2.73
7.85 2.50 9.05 2.61 10.49 2.74
7.70 2.52 8.90 2.63 10.35 2.77
7.97 2.50 9.13 2.61 10.51 2.75
7.83 2.52 8.99 2.64 10.37 2.77
7.69 2.55 8.84 2.66 10.23 2.80
7.62 2.56 8.77 2.67 10.16 2.81
7.55 2.57 8.70 2.69 10.09 2.83
7.41 2.60 8.56 2.71 9.95 2.85
8.11 2.57 9.29 2.69 10.70 2.83
7.97 2.59 9.14 2.71 10.55 2.85
7.82 2.62 9.00 2.74 10.41 2.88
7.75 2.63 8.93 2.75 10.34 2.89
7.68 2.65 8.86 2.76 10.27 2.91
7.54 2.67 8.71 2.79 10.12 2.93
8.27 2.39 9.47 2.50 10.90 2.63
8.12 2.41 9.32 2.52 10.76 2.66
7.97 2.44 9.17 2.55 10.61 2.68
7.90 2.45 9.10 2.56 10.54 2.69
7.83 2.46 9.03 2.57 10.46 2.70
7.68 2.49 8.88 2.60 10.32 2.73

10C
TC
PI
kW
kW
11.70 2.66
11.56 2.68
11.42 2.71
11.34 2.72
11.27 2.73
11.13 2.75
11.85 2.65
11.70 2.67
11.56 2.70
11.48 2.71
11.41 2.72
11.26 2.74
11.31 2.77
11.17 2.80
11.03 2.82
10.96 2.83
10.89 2.84
10.75 2.87
11.40 2.84
11.26 2.87
11.12 2.89
11.05 2.90
10.98 2.92
10.84 2.94
11.86 2.69
11.71 2.71
11.57 2.74
11.50 2.75
11.42 2.76
11.28 2.79
11.89 2.61
11.75 2.63
11.60 2.65
11.53 2.67
11.45 2.68
11.31 2.70
11.64 2.88
11.49 2.91
11.35 2.93
11.28 2.95
11.21 2.96
11.06 2.98
11.89 2.76
11.75 2.79
11.60 2.81
11.53 2.82
11.45 2.83
11.31 2.86
11.44 2.84
11.30 2.87
11.15 2.89
11.08 2.90
11.01 2.92
10.87 2.94
11.64 2.92
11.49 2.95
11.35 2.97
11.28 2.99
11.21 3.00
11.06 3.03
11.86 2.72
11.71 2.74
11.57 2.77
11.50 2.78
11.42 2.79
11.28 2.82

15C
TC
PI
kW
kW
12.89 2.77
12.74 2.79
12.60 2.81
12.53 2.83
12.45 2.84
12.31 2.86
13.05 2.76
12.90 2.78
12.75 2.80
12.68 2.82
12.61 2.83
12.46 2.85
12.46 2.88
12.32 2.91
12.18 2.93
12.11 2.94
12.04 2.96
11.90 2.98
12.55 2.96
12.41 2.98
12.27 3.01
12.20 3.02
12.13 3.03
11.99 3.06
13.06 2.80
12.91 2.82
12.77 2.85
12.69 2.86
12.62 2.87
12.47 2.89
13.10 2.71
12.95 2.74
12.80 2.76
12.73 2.77
12.66 2.78
12.51 2.81
12.81 3.00
12.67 3.02
12.53 3.05
12.45 3.06
12.38 3.08
12.24 3.10
13.10 2.87
12.95 2.90
12.80 2.92
12.73 2.93
12.66 2.95
12.51 2.97
12.59 2.96
12.45 2.98
12.31 3.01
12.24 3.02
12.17 3.03
12.03 3.06
12.81 3.04
12.67 3.07
12.53 3.09
12.45 3.11
12.38 3.12
12.24 3.15
13.06 2.83
12.91 2.85
12.77 2.88
12.69 2.89
12.62 2.90
12.47 2.93

83

Capacity Tables

Combination
(Capacity)
2.5+2.5+6.0

2.5+3.5+3.5

2.5+3.5+5.0

3.5+3.5+3.5

EDAU12-722

Indoor
air temp.
CDB
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0

Symbols

-15C
TC
PI
kW
kW
5.89 2.09
5.74 2.11
5.59 2.13
5.52 2.15
5.45 2.16
5.30 2.18
5.84 2.33
5.70 2.36
5.55 2.38
5.48 2.39
5.41 2.41
5.26 2.43
5.89 2.16
5.74 2.18
5.59 2.21
5.52 2.22
5.45 2.23
5.30 2.26
5.88 2.38
5.73 2.41
5.58 2.43
5.51 2.44
5.44 2.46
5.29 2.48

-10C
TC
PI
kW
kW
7.09 2.19
6.94 2.22
6.80 2.24
6.72 2.25
6.65 2.26
6.50 2.29
7.04 2.45
6.89 2.47
6.74 2.50
6.67 2.51
6.60 2.53
6.45 2.55
7.09 2.27
6.94 2.29
6.80 2.32
6.72 2.33
6.65 2.34
6.50 2.37
7.08 2.50
6.93 2.53
6.78 2.55
6.71 2.57
6.64 2.58
6.49 2.61

Outdoor air temp.:CWB


-5C
0C
6C
TC
PI
TC
PI
TC
PI
kW
kW
kW
kW
kW
kW
8.29 2.30 9.49 2.41 10.93 2.53
8.14 2.32 9.35 2.43 10.79 2.56
8.00 2.35 9.20 2.45 10.64 2.58
7.92 2.36 9.12 2.46 10.57 2.59
7.85 2.37 9.05 2.48 10.49 2.60
7.70 2.39 8.90 2.50 10.35 2.63
8.23 2.57 9.42 2.69 10.85 2.83
8.08 2.59 9.27 2.71 10.71 2.85
7.94 2.62 9.13 2.74 10.56 2.88
7.86 2.63 9.06 2.75 10.49 2.89
7.79 2.65 8.98 2.76 10.41 2.91
7.65 2.67 8.84 2.79 10.27 2.93
8.29 2.38 9.49 2.49 10.93 2.62
8.14 2.40 9.35 2.51 10.79 2.65
8.00 2.43 9.20 2.54 10.64 2.67
7.92 2.44 9.12 2.55 10.57 2.68
7.85 2.45 9.05 2.56 10.49 2.69
7.70 2.48 8.90 2.59 10.35 2.72
8.28 2.62 9.47 2.74 10.91 2.89
8.13 2.65 9.33 2.77 10.77 2.91
7.98 2.67 9.18 2.79 10.62 2.94
7.91 2.69 9.11 2.81 10.55 2.95
7.84 2.70 9.03 2.82 10.47 2.97
7.69 2.73 8.89 2.85 10.33 2.99

10C
TC
PI
kW
kW
11.89 2.62
11.75 2.64
11.60 2.66
11.53 2.68
11.45 2.69
11.31 2.71
11.81 2.92
11.66 2.95
11.51 2.97
11.44 2.99
11.37 3.00
11.22 3.03
11.89 2.71
11.75 2.73
11.60 2.76
11.53 2.77
11.45 2.78
11.31 2.81
11.87 2.98
11.73 3.01
11.58 3.04
11.51 3.05
11.43 3.06
11.29 3.09

15C
TC
PI
kW
kW
13.10 2.72
12.95 2.75
12.80 2.77
12.73 2.78
12.66 2.79
12.51 2.82
13.00 3.04
12.85 3.07
12.71 3.09
12.63 3.11
12.56 3.12
12.41 3.15
13.10 2.82
12.95 2.84
12.80 2.87
12.73 2.88
12.66 2.89
12.51 2.92
13.07 3.10
12.93 3.13
12.78 3.16
12.71 3.17
12.63 3.18
12.49 3.21

NOTE:

TC

: Total capacity

(kW)

PI

: Power input

(kW)

Capacities are based on the following conditions.


Corresponding refrigerant piping length : 7.5m
Level difference : 0m
3D055095
3D055096
3D055097

84

SUPER MULTI NX E-Series Heat Pump

EDAU12-722

Capacity Tables

[Cooling Capacity 50Hz 240V]


Combination
(Capacity)
2.0

2.5

3.5

5.0

6.0

2.0+2.0

2.0+2.5

2.0+3.5

2.0+5.0

2.0+6.0

Outdoor
air temp.
CDB
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0

SUPER MULTI NX E-Series Heat Pump

14C
TC
PI
kW
kW
2.59
0.55
2.51
0.57
2.35
0.62
2.27
0.64
2.15
0.69
2.08
0.71
2.01
0.74
2.63
0.54
2.63
0.57
2.63
0.68
2.63
0.73
2.63
0.84
2.63
0.91
2.63
0.99
3.00
0.62
3.00
0.67
3.00
0.78
3.00
0.84
3.00
0.96
3.00
1.04
3.00
1.13
5.32
1.47
5.32
1.59
5.32
1.95
5.20
2.06
4.93
2.19
4.76
2.27
4.60
2.36
5.60
1.59
5.60
1.72
5.60
2.11
5.60
2.33
5.32
2.49
5.15
2.59
4.96
2.67
5.05
1.31
4.91
1.35
4.58
1.47
4.44
1.53
4.21
1.63
4.07
1.69
3.93
1.75
5.26
1.40
5.19
1.49
4.85
1.62
4.70
1.68
4.45
1.79
4.30
1.86
4.15
1.93
5.63
1.63
5.63
1.77
5.63
2.18
5.49
2.29
5.20
2.43
5.02
2.53
4.85
2.62
7.14
2.06
6.94
2.14
6.48
2.33
6.28
2.41
5.95
2.57
5.75
2.66
5.51
2.67
7.62
2.27
7.41
2.35
6.92
2.56
6.71
2.65
6.35
2.82
6.14
2.93
5.80
2.67

16C
TC
PI
kW
kW
2.70
0.56
2.63
0.58
2.46
0.63
2.39
0.65
2.27
0.70
2.20
0.72
2.13
0.75
3.23
0.67
3.23
0.72
3.23
0.85
3.16
0.89
3.00
0.95
2.90
0.98
2.81
1.02
3.68
0.78
3.68
0.84
3.68
0.99
3.68
1.06
3.68
1.22
3.68
1.32
3.68
1.44
6.19
1.79
6.02
1.86
5.64
2.02
5.47
2.09
5.20
2.22
5.04
2.31
4.87
2.39
6.68
2.04
6.50
2.12
6.09
2.30
5.91
2.38
5.62
2.53
5.44
2.63
5.24
2.67
5.28
1.33
5.14
1.38
4.81
1.50
4.67
1.55
4.44
1.65
4.30
1.71
4.16
1.78
5.59
1.47
5.44
1.52
5.09
1.65
4.94
1.71
4.70
1.82
4.55
1.89
4.40
1.96
6.52
1.99
6.35
2.06
5.94
2.24
5.77
2.33
5.48
2.47
5.31
2.56
5.14
2.66
7.47
2.10
7.27
2.18
6.81
2.37
6.61
2.45
6.28
2.61
6.08
2.70
5.81
2.67
7.97
2.31
7.76
2.39
7.27
2.60
7.06
2.70
6.70
2.87
6.49
2.97
6.10
2.67

Indoor air temp.:CWB


18C
19C
TC
PI
TC
PI
kW
kW
kW
kW
2.82
0.57
2.88
0.58
2.75
0.59
2.81
0.60
2.58
0.64
2.64
0.65
2.51
0.67
2.57
0.67
2.39
0.71
2.45
0.71
2.32
0.73
2.38
0.74
2.25
0.76
2.31
0.77
3.72
0.78
3.80
0.78
3.63
0.80
3.71
0.81
3.41
0.87
3.48
0.88
3.31
0.90
3.39
0.91
3.15
0.96
3.23
0.97
3.06
0.99
3.14
1.00
2.96
1.03
3.04
1.04
4.42
0.96
4.81
1.07
4.42
1.03
4.81
1.14
4.42
1.22
4.81
1.36
4.42
1.32
4.73
1.43
4.40
1.51
4.51
1.52
4.27
1.56
4.38
1.58
4.14
1.62
4.25
1.63
6.46
1.83
6.59
1.84
6.29
1.89
6.43
1.91
5.91
2.05
6.04
2.07
5.74
2.13
5.88
2.14
5.47
2.26
5.61
2.27
5.31
2.34
5.44
2.36
5.14
2.43
5.28
2.44
6.97
2.08
7.12
2.10
6.80
2.16
6.94
2.17
6.38
2.34
6.53
2.36
6.20
2.42
6.35
2.44
5.91
2.57
6.05
2.59
5.73
2.67
5.88
2.69
5.51
2.67
5.65
2.67
5.51
1.36
5.63
1.37
5.37
1.40
5.49
1.42
5.04
1.52
5.16
1.54
4.90
1.58
5.02
1.59
4.67
1.68
4.79
1.69
4.53
1.74
4.65
1.75
4.39
1.80
4.51
1.82
5.83
1.49
5.95
1.51
5.68
1.55
5.80
1.56
5.34
1.68
5.46
1.69
5.19
1.74
5.31
1.75
4.94
1.85
5.06
1.86
4.79
1.91
4.91
1.93
4.64
1.98
4.77
2.00
6.81
2.03
6.95
2.05
6.63
2.10
6.78
2.12
6.23
2.28
6.37
2.30
6.06
2.36
6.20
2.38
5.77
2.51
5.91
2.53
5.60
2.60
5.74
2.62
5.41
2.67
5.54
2.67
7.80
2.14
7.96
2.16
7.60
2.22
7.76
2.24
7.13
2.41
7.30
2.43
6.94
2.49
7.10
2.51
6.61
2.65
6.77
2.67
6.41
2.74
6.57
2.76
6.11
2.67
6.25
2.67
8.32
2.36
8.50
2.38
8.11
2.44
8.29
2.46
7.62
2.64
7.79
2.67
7.41
2.74
7.58
2.76
7.05
2.91
7.23
2.93
6.84
3.02
7.02
3.04
6.39
2.67
6.53
2.67

22C
TC
PI
kW
kW
3.06
0.59
2.99
0.61
2.82
0.66
2.75
0.69
2.63
0.73
2.56
0.75
2.48
0.78
4.03
0.81
3.94
0.83
3.72
0.90
3.62
0.93
3.47
0.99
3.37
1.02
3.28
1.06
5.63
1.27
5.50
1.31
5.19
1.42
5.06
1.47
4.84
1.55
4.70
1.61
4.57
1.67
7.00
1.90
6.83
1.96
6.45
2.12
6.29
2.19
6.01
2.33
5.85
2.41
5.68
2.50
7.56
2.16
7.38
2.23
6.97
2.42
6.79
2.50
6.49
2.65
6.32
2.75
6.04
2.67
5.97
1.41
5.83
1.46
5.51
1.57
5.37
1.63
5.13
1.73
4.99
1.79
4.85
1.85
6.32
1.55
6.17
1.60
5.83
1.73
5.68
1.79
5.43
1.90
5.28
1.97
5.13
2.04
7.38
2.11
7.21
2.18
6.80
2.36
6.63
2.44
6.34
2.59
6.17
2.68
5.93
2.67
8.45
2.22
8.25
2.30
7.79
2.49
7.59
2.57
7.26
2.73
7.06
2.82
6.67
2.67
9.02
2.44
8.81
2.53
8.32
2.73
8.10
2.83
7.75
3.00
7.54
3.11
6.95
2.67

24C
TC
PI
kW
kW
3.18
0.60
3.11
0.62
2.94
0.67
2.87
0.70
2.75
0.74
2.67
0.76
2.60
0.79
4.19
0.82
4.10
0.85
3.88
0.92
3.78
0.95
3.62
1.00
3.53
1.04
3.43
1.08
5.85
1.29
5.72
1.33
5.41
1.44
5.27
1.49
5.05
1.58
4.92
1.63
4.79
1.69
7.27
1.93
7.10
1.99
6.72
2.15
6.56
2.23
6.28
2.36
6.12
2.44
5.95
2.53
7.85
2.20
7.67
2.27
7.26
2.46
7.08
2.54
6.79
2.69
6.61
2.79
6.29
2.67
6.21
1.43
6.07
1.48
5.74
1.60
5.60
1.66
5.36
1.75
5.22
1.81
5.08
1.88
6.56
1.58
6.42
1.63
6.07
1.76
5.92
1.82
5.67
1.93
5.53
2.00
5.38
2.07
7.66
2.15
7.49
2.22
7.09
2.40
6.91
2.48
6.63
2.62
6.45
2.72
6.19
2.67
8.78
2.26
8.58
2.34
8.12
2.53
7.92
2.61
7.59
2.77
7.39
2.86
6.94
2.67
9.37
2.49
9.16
2.57
8.66
2.78
8.45
2.87
8.10
3.04
7.89
3.15
7.23
2.67

85

Capacity Tables

Combination
(Capacity)
2.5+2.5

2.5+3.5

2.5+5.0

2.5+6.0

3.5+3.5

3.5+5.0

3.5+6.0

5.0+5.0

5.0+6.0

2.0+2.0+2.0

86

EDAU12-722

Outdoor
air temp.
CDB
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0

14C
TC
PI
kW
kW
5.26
1.44
5.26
1.56
5.26
1.90
5.26
2.09
5.00
2.24
4.84
2.32
4.67
2.41
5.63
1.68
5.63
1.82
5.63
2.24
5.63
2.47
5.39
2.69
5.21
2.79
5.00
2.67
7.29
2.17
7.09
2.25
6.62
2.45
6.41
2.54
6.08
2.70
5.87
2.80
5.59
2.67
7.64
2.33
7.43
2.42
6.94
2.63
6.72
2.73
6.37
2.90
6.16
3.01
5.81
2.67
6.00
1.75
6.00
1.90
6.00
2.34
6.00
2.58
5.84
2.91
5.65
3.02
5.39
2.67
7.67
2.36
7.46
2.44
6.96
2.66
6.75
2.76
6.40
2.93
6.18
3.05
5.83
2.67
7.95
2.56
7.73
2.65
7.21
2.88
6.99
2.99
6.62
3.18
6.40
3.27
6.02
2.67
8.16
2.42
7.93
2.51
7.40
2.73
7.18
2.84
6.80
3.02
6.57
3.13
6.14
2.67
8.34
2.51
8.11
2.61
7.57
2.83
7.34
2.94
6.95
3.13
6.72
3.25
6.26
2.67
6.49
1.60
6.31
1.66
5.89
1.81
5.71
1.87
5.41
1.99
5.23
2.07
5.05
2.15

16C
TC
PI
kW
kW
6.28
1.83
6.11
1.90
5.72
2.06
5.56
2.14
5.28
2.27
5.11
2.36
4.95
2.45
6.76
2.20
6.58
2.28
6.17
2.48
5.99
2.57
5.69
2.73
5.51
2.83
5.27
2.67
7.63
2.21
7.42
2.29
6.95
2.49
6.75
2.58
6.41
2.74
6.21
2.84
5.88
2.67
7.99
2.38
7.78
2.46
7.29
2.68
7.07
2.77
6.72
2.95
6.51
3.06
6.10
2.67
7.33
2.39
7.14
2.47
6.68
2.69
6.49
2.78
6.16
2.96
5.97
3.07
5.66
2.67
8.03
2.40
7.81
2.49
7.32
2.70
7.10
2.80
6.75
2.98
6.53
3.09
6.12
2.67
8.31
2.61
8.09
2.70
7.57
2.93
7.35
3.04
6.99
3.23
6.76
3.27
6.31
2.67
8.53
2.47
8.30
2.56
7.78
2.78
7.55
2.88
7.17
3.06
6.95
3.18
6.44
2.67
8.72
2.56
8.49
2.65
7.95
2.88
7.72
2.99
7.33
3.18
7.10
3.27
6.56
2.67
6.79
1.63
6.60
1.69
6.18
1.84
6.00
1.91
5.70
2.03
5.52
2.10
5.34
2.18

Indoor air temp.:CWB


18C
19C
TC
PI
TC
PI
kW
kW
kW
kW
6.56
1.87
6.69
1.89
6.39
1.93
6.53
1.95
6.00
2.10
6.14
2.12
5.83
2.17
5.97
2.19
5.55
2.31
5.69
2.33
5.39
2.39
5.53
2.41
5.22
2.48
5.36
2.50
7.06
2.25
7.21
2.27
6.88
2.32
7.03
2.34
6.46
2.52
6.61
2.54
6.28
2.61
6.43
2.63
5.98
2.77
6.13
2.79
5.80
2.88
5.95
2.90
5.53
2.67
5.66
2.67
7.96
2.25
8.13
2.28
7.76
2.33
7.93
2.35
7.29
2.53
7.45
2.55
7.08
2.62
7.25
2.64
6.75
2.78
6.91
2.80
6.54
2.89
6.71
2.91
6.17
2.67
6.31
2.67
8.35
2.42
8.52
2.45
8.13
2.51
8.31
2.53
7.64
2.72
7.81
2.74
7.42
2.82
7.60
2.84
7.07
2.99
7.25
3.02
6.86
3.11
7.03
3.13
6.39
2.67
6.53
2.67
7.65
2.43
7.81
2.46
7.46
2.52
7.62
2.54
7.00
2.73
7.16
2.75
6.81
2.83
6.97
2.85
6.48
3.01
6.65
3.03
6.29
3.12
6.45
3.14
5.93
2.67
6.07
2.67
8.38
2.45
8.55
2.47
8.16
2.54
8.34
2.56
7.67
2.75
7.84
2.77
7.45
2.85
7.63
2.87
7.10
3.03
7.27
3.05
6.89
3.14
7.06
3.16
6.41
2.67
6.55
2.67
8.67
2.66
8.86
2.68
8.45
2.75
8.64
2.77
7.94
2.98
8.12
3.01
7.72
3.09
7.90
3.11
7.35
3.28
7.53
3.30
7.11
3.27
7.29
3.27
6.60
2.67
6.74
2.67
8.91
2.52
9.09
2.54
8.68
2.61
8.87
2.63
8.15
2.83
8.34
2.85
7.92
2.93
8.11
2.95
7.55
3.11
7.73
3.13
7.32
3.23
7.51
3.25
6.74
2.67
6.88
2.67
9.10
2.61
9.29
2.64
8.87
2.70
9.06
2.73
8.33
2.93
8.52
2.96
8.10
3.04
8.29
3.06
7.71
3.23
7.90
3.25
7.46
3.27
7.64
3.27
6.86
2.67
7.00
2.67
7.08
1.66
7.23
1.68
6.90
1.72
7.05
1.74
6.48
1.87
6.63
1.88
6.30
1.94
6.45
1.95
6.00
2.06
6.15
2.07
5.82
2.13
5.97
2.15
5.64
2.21
5.79
2.23

22C
TC
PI
kW
kW
7.11
1.94
6.94
2.00
6.55
2.17
6.38
2.24
6.10
2.38
5.94
2.46
5.77
2.55
7.65
2.33
7.47
2.41
7.05
2.60
6.87
2.70
6.57
2.86
6.40
2.96
6.04
2.67
8.63
2.34
8.43
2.42
7.95
2.61
7.75
2.71
7.41
2.87
7.21
2.97
6.73
2.67
9.05
2.52
8.83
2.60
8.34
2.81
8.13
2.91
7.77
3.09
7.56
3.20
6.95
2.67
8.30
2.52
8.10
2.61
7.65
2.82
7.45
2.92
7.13
3.10
6.93
3.21
6.46
2.67
9.08
2.54
8.87
2.63
8.37
2.84
8.16
2.94
7.80
3.12
7.59
3.23
6.96
2.67
9.40
2.75
9.18
2.85
8.67
3.08
8.45
3.19
8.08
3.38
7.79
3.27
7.15
2.67
9.65
2.61
9.43
2.70
8.90
2.92
8.67
3.02
8.29
3.21
8.04
3.27
7.31
2.67
9.87
2.71
9.63
2.80
9.09
3.03
8.86
3.14
8.48
3.32
8.17
3.27
7.43
2.67
7.68
1.73
7.50
1.78
7.08
1.93
6.90
2.00
6.60
2.12
6.42
2.19
6.24
2.27

24C
TC
PI
kW
kW
7.38
1.97
7.21
2.04
6.82
2.20
6.66
2.28
6.38
2.41
6.21
2.50
6.05
2.59
7.95
2.37
7.77
2.45
7.35
2.65
7.17
2.74
6.87
2.90
6.69
3.00
6.29
2.67
8.96
2.38
8.76
2.46
8.29
2.66
8.09
2.75
7.75
2.91
7.54
3.01
7.00
2.67
9.40
2.56
9.18
2.65
8.69
2.86
8.48
2.96
8.12
3.13
7.91
3.24
7.22
2.67
8.62
2.57
8.42
2.65
7.97
2.87
7.77
2.97
7.45
3.14
7.25
3.25
6.71
2.67
9.43
2.59
9.22
2.67
8.72
2.89
8.51
2.99
8.15
3.16
7.94
3.27
7.23
2.67
9.77
2.80
9.55
2.90
9.03
3.13
8.81
3.24
8.44
3.43
8.12
3.27
7.42
2.67
10.03 2.66
9.80
2.75
9.27
2.97
9.04
3.07
8.67
3.25
8.39
3.27
7.59
2.67
10.25 2.76
10.02 2.85
9.48
3.08
9.24
3.19
8.86
3.37
8.52
3.27
7.71
2.67
7.97
1.76
7.79
1.82
7.37
1.96
7.19
2.03
6.89
2.15
6.71
2.23
6.53
2.30

SUPER MULTI NX E-Series Heat Pump

EDAU12-722

Combination
(Capacity)
2.0+2.0+2.5

2.0+2.0+3.5

2.0+2.0+5.0

2.0+2.0+6.0

2.0+2.5+2.5

2.0+2.5+3.5

2.0+2.5+5.0

2.0+2.5+6.0

2.0+3.5+3.5

2.0+3.5+5.0

Capacity Tables

Outdoor
air temp.
CDB
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0

SUPER MULTI NX E-Series Heat Pump

14C
TC
PI
kW
kW
6.89
1.79
6.70
1.86
6.25
2.02
6.06
2.10
5.74
2.23
5.55
2.31
5.36
2.40
7.25
2.03
7.05
2.10
6.58
2.29
6.38
2.37
6.04
2.53
5.84
2.62
5.62
2.67
7.95
2.21
7.73
2.29
7.21
2.49
6.99
2.59
6.62
2.75
6.40
2.86
6.04
2.67
8.20
2.32
7.97
2.40
7.44
2.61
7.21
2.71
6.83
2.88
6.60
2.99
6.18
2.67
7.14
1.96
6.94
2.03
6.48
2.20
6.28
2.29
5.95
2.43
5.75
2.53
5.55
2.62
7.62
2.20
7.41
2.28
6.92
2.48
6.71
2.58
6.35
2.74
6.14
2.84
5.81
2.67
7.98
2.21
7.76
2.29
7.24
2.49
7.02
2.59
6.65
2.75
6.43
2.86
6.06
2.67
8.42
2.47
8.19
2.56
7.64
2.79
7.41
2.89
7.02
3.08
6.78
3.19
6.30
2.67
7.93
2.46
7.71
2.55
7.19
2.77
6.97
2.87
6.61
3.06
6.39
3.17
5.99
2.67
8.42
2.56
8.19
2.66
7.64
2.89
7.41
3.00
7.02
3.19
6.78
3.27
6.31
2.67

16C
TC
PI
kW
kW
7.21
1.83
7.01
1.89
6.57
2.05
6.38
2.13
6.06
2.26
5.87
2.35
5.67
2.44
7.58
2.07
7.38
2.14
6.91
2.33
6.71
2.41
6.38
2.57
6.17
2.66
5.92
2.67
8.31
2.25
8.09
2.33
7.57
2.53
7.35
2.63
6.99
2.79
6.77
2.90
6.35
2.67
8.57
2.36
8.35
2.45
7.81
2.66
7.59
2.76
7.21
2.93
6.98
3.04
6.49
2.67
7.47
1.99
7.27
2.06
6.81
2.24
6.61
2.33
6.28
2.47
6.08
2.56
5.88
2.66
7.97
2.25
7.76
2.32
7.27
2.53
7.06
2.62
6.70
2.78
6.49
2.89
6.12
2.67
8.34
2.25
8.12
2.33
7.60
2.53
7.38
2.63
7.01
2.79
6.79
2.90
6.37
2.67
8.80
2.52
8.57
2.61
8.03
2.84
7.79
2.94
7.40
3.13
7.17
3.24
6.61
2.67
8.29
2.51
8.07
2.59
7.56
2.82
7.34
2.92
6.97
3.11
6.75
3.22
6.29
2.67
8.80
2.61
8.57
2.71
8.03
2.94
7.79
3.05
7.40
3.24
7.15
3.27
6.61
2.67

Indoor air temp.:CWB


18C
19C
TC
PI
TC
PI
kW
kW
kW
kW
7.52
1.86
7.68
1.88
7.33
1.93
7.49
1.94
6.88
2.09
7.04
2.11
6.69
2.16
6.85
2.18
6.37
2.30
6.53
2.32
6.18
2.38
6.34
2.40
5.99
2.47
6.15
2.49
7.92
2.11
8.08
2.13
7.72
2.18
7.88
2.20
7.25
2.37
7.41
2.39
7.04
2.45
7.21
2.47
6.71
2.60
6.87
2.62
6.51
2.70
6.67
2.72
6.22
2.67
6.37
2.67
8.67
2.30
8.86
2.32
8.45
2.38
8.64
2.40
7.94
2.58
8.12
2.60
7.72
2.67
7.90
2.69
7.35
2.84
7.53
2.86
7.13
2.94
7.31
2.96
6.65
2.67
6.80
2.67
8.95
2.41
9.14
2.43
8.72
2.49
8.91
2.51
8.19
2.70
8.38
2.72
7.96
2.80
8.15
2.82
7.58
2.97
7.77
3.00
7.36
3.08
7.54
3.11
6.79
2.67
6.94
2.67
7.80
2.03
7.96
2.05
7.60
2.10
7.76
2.12
7.13
2.28
7.30
2.30
6.94
2.36
7.10
2.38
6.61
2.51
6.77
2.53
6.41
2.60
6.57
2.62
6.19
2.67
6.34
2.67
8.32
2.29
8.50
2.31
8.11
2.37
8.29
2.39
7.62
2.57
7.79
2.59
7.41
2.66
7.58
2.68
7.05
2.83
7.23
2.85
6.84
2.93
7.02
2.95
6.41
2.67
6.56
2.67
8.71
2.30
8.89
2.32
8.49
2.38
8.67
2.40
7.97
2.58
8.15
2.60
7.75
2.67
7.93
2.69
7.38
2.84
7.56
2.86
7.16
2.94
7.34
2.96
6.68
2.67
6.83
2.67
9.19
2.57
9.38
2.59
8.96
2.66
9.15
2.68
8.41
2.88
8.60
2.91
8.18
2.99
8.37
3.01
7.79
3.17
7.98
3.20
7.55
3.27
7.73
3.27
6.91
2.67
7.06
2.67
8.65
2.55
8.83
2.58
8.43
2.64
8.61
2.67
7.92
2.87
8.10
2.89
7.70
2.97
7.88
2.99
7.33
3.15
7.51
3.18
7.11
3.27
7.29
3.27
6.58
2.67
6.72
2.67
9.19
2.66
9.38
2.69
8.96
2.76
9.15
2.78
8.41
2.99
8.60
3.01
8.18
3.10
8.37
3.12
7.79
3.29
7.98
3.31
7.52
3.27
7.70
3.27
6.91
2.67
7.06
2.67

22C
TC
PI
kW
kW
8.15
1.93
7.96
2.00
7.51
2.16
7.32
2.23
7.00
2.37
6.81
2.45
6.62
2.54
8.58
2.19
8.38
2.26
7.91
2.45
7.71
2.53
7.37
2.68
7.17
2.78
6.80
2.67
9.40
2.38
9.18
2.46
8.67
2.66
8.45
2.76
8.08
2.92
7.86
3.03
7.24
2.67
9.70
2.50
9.47
2.58
8.94
2.79
8.71
2.89
8.33
3.06
8.11
3.17
7.38
2.67
8.45
2.11
8.25
2.18
7.79
2.36
7.59
2.44
7.26
2.59
7.06
2.68
6.77
2.67
9.02
2.37
8.81
2.45
8.32
2.65
8.10
2.75
7.75
2.91
7.54
3.02
6.99
2.67
9.44
2.38
9.22
2.46
8.70
2.66
8.48
2.76
8.11
2.92
7.89
3.03
7.27
2.67
9.96
2.67
9.73
2.76
9.18
2.98
8.95
3.09
8.56
3.27
8.27
3.27
7.50
2.67
9.38
2.65
9.16
2.74
8.64
2.96
8.42
3.06
8.06
3.25
7.80
3.27
7.14
2.67
9.96
2.76
9.73
2.86
9.18
3.09
8.95
3.20
8.56
3.39
8.23
3.27
7.48
2.67

24C
TC
PI
kW
kW
8.47
1.97
8.28
2.03
7.83
2.19
7.64
2.27
7.32
2.40
7.13
2.49
6.94
2.58
8.91
2.23
8.71
2.30
8.24
2.49
8.04
2.57
7.70
2.72
7.50
2.82
7.07
2.67
9.77
2.43
9.55
2.51
9.03
2.71
8.81
2.80
8.44
2.97
8.22
3.07
7.53
2.67
10.08 2.54
9.85
2.63
9.32
2.84
9.09
2.94
8.71
3.11
8.48
3.22
7.67
2.67
8.78
2.15
8.58
2.22
8.12
2.40
7.92
2.48
7.59
2.62
7.39
2.72
7.05
2.67
9.37
2.42
9.16
2.50
8.66
2.70
8.45
2.79
8.10
2.95
7.89
3.06
7.26
2.67
9.80
2.43
9.58
2.51
9.06
2.71
8.84
2.80
8.47
2.97
8.25
3.07
7.56
2.67
10.35 2.71
10.11 2.80
9.57
3.03
9.33
3.13
8.94
3.32
8.62
3.27
7.78
2.67
9.74
2.70
9.52
2.78
9.01
3.01
8.79
3.11
8.42
3.30
8.14
3.27
7.41
2.67
10.35 2.81
10.11 2.91
9.57
3.14
9.33
3.25
8.94
3.44
8.57
3.27
7.76
2.67

87

Capacity Tables

Combination
(Capacity)
2.5+2.5+2.5

2.5+2.5+3.5

2.5+2.5+5.0

2.5+2.5+6.0

2.5+3.5+3.5

2.5+3.5+5.0

3.5+3.5+3.5

EDAU12-722

Outdoor
air temp.
CDB
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0

Symbols

14C
TC
PI
kW
kW
7.49
2.12
7.29
2.20
6.80
2.39
6.59
2.48
6.25
2.64
6.04
2.74
5.75
2.67
7.84
2.35
7.62
2.43
7.11
2.65
6.89
2.75
6.53
2.92
6.31
3.04
5.93
2.67
8.32
2.43
8.09
2.52
7.55
2.74
7.32
2.84
6.93
3.03
6.70
3.14
6.24
2.67
8.58
2.61
8.34
2.71
7.79
2.95
7.55
3.06
7.15
3.25
6.90
3.27
6.42
2.67
8.16
2.63
7.93
2.72
7.40
2.96
7.18
3.08
6.80
3.27
6.57
3.27
6.17
2.67
8.58
2.67
8.34
2.77
7.79
3.01
7.55
3.12
7.15
3.32
6.90
3.27
6.43
2.67
8.49
2.74
8.25
2.83
7.70
3.08
7.47
3.20
7.07
3.40
6.84
3.27
6.40
2.67

16C
TC
PI
kW
kW
7.84
2.16
7.63
2.24
7.14
2.43
6.94
2.52
6.59
2.68
6.38
2.78
6.05
2.67
8.19
2.40
7.98
2.48
7.47
2.70
7.25
2.79
6.89
2.97
6.67
3.08
6.23
2.67
8.70
2.48
8.47
2.57
7.93
2.79
7.70
2.89
7.31
3.07
7.08
3.19
6.55
2.67
8.97
2.66
8.73
2.76
8.18
3.00
7.94
3.11
7.54
3.30
7.28
3.27
6.72
2.67
8.53
2.68
8.30
2.78
7.78
3.02
7.55
3.13
7.17
3.32
6.94
3.27
6.46
2.67
8.97
2.72
8.73
2.82
8.18
3.06
7.94
3.18
7.54
3.38
7.28
3.27
6.73
2.67
8.88
2.79
8.64
2.89
8.09
3.14
7.86
3.25
7.46
3.46
7.21
3.27
6.70
2.67

Indoor air temp.:CWB


18C
19C
TC
PI
TC
PI
kW
kW
kW
kW
8.18
2.20
8.35
2.22
7.97
2.28
8.14
2.30
7.49
2.47
7.66
2.49
7.28
2.56
7.45
2.58
6.93
2.72
7.10
2.74
6.72
2.82
6.89
2.84
6.35
2.67
6.50
2.67
8.55
2.44
8.73
2.46
8.34
2.53
8.52
2.55
7.83
2.74
8.01
2.76
7.61
2.84
7.79
2.86
7.25
3.02
7.43
3.04
7.03
3.13
7.21
3.15
6.52
2.67
6.67
2.67
9.08
2.53
9.27
2.55
8.85
2.61
9.04
2.64
8.31
2.84
8.50
2.86
8.08
2.94
8.27
2.96
7.69
3.12
7.88
3.14
7.46
3.24
7.65
3.26
6.85
2.67
7.00
2.67
9.37
2.72
9.56
2.74
9.13
2.81
9.32
2.83
8.57
3.05
8.77
3.07
8.33
3.16
8.53
3.18
7.94
3.35
8.13
3.38
7.65
3.27
7.83
3.27
7.02
2.67
7.16
2.67
8.91
2.73
9.09
2.76
8.68
2.83
8.87
2.85
8.15
3.07
8.34
3.09
7.92
3.18
8.11
3.20
7.55
3.37
7.73
3.40
7.29
3.27
7.46
3.27
6.75
2.67
6.89
2.67
9.37
2.77
9.56
2.80
9.13
2.87
9.32
2.90
8.57
3.11
8.77
3.14
8.33
3.23
8.53
3.25
7.94
3.43
8.13
3.45
7.64
3.27
7.82
3.27
7.03
2.67
7.17
2.67
9.27
2.84
9.46
2.87
9.03
2.94
9.23
2.97
8.48
3.19
8.68
3.22
8.25
3.31
8.44
3.33
7.85
3.51
8.05
3.54
7.57
3.27
7.75
3.27
6.99
2.67
7.13
2.67

22C
TC
PI
kW
kW
8.87
2.29
8.66
2.36
8.17
2.56
7.96
2.64
7.62
2.80
7.41
2.90
6.93
2.67
9.27
2.53
9.05
2.62
8.55
2.83
8.33
2.93
7.97
3.11
7.75
3.22
7.09
2.67
9.84
2.62
9.61
2.71
9.07
2.93
8.84
3.03
8.46
3.22
8.20
3.27
7.43
2.67
10.15 2.82
9.91
2.91
9.36
3.15
9.12
3.26
8.72
3.45
8.36
3.27
7.60
2.67
9.65
2.83
9.43
2.93
8.90
3.17
8.67
3.28
8.29
3.48
7.98
3.27
7.30
2.67
10.15 2.88
9.91
2.97
9.36
3.22
9.12
3.33
8.72
3.53
8.35
3.27
7.60
2.67
10.05 2.95
9.81
3.05
9.26
3.30
9.02
3.41
8.63
3.62
8.26
3.27
7.55
2.67

24C
TC
PI
kW
kW
9.21
2.33
9.00
2.40
8.52
2.60
8.31
2.69
7.96
2.84
7.75
2.94
7.21
2.67
9.63
2.58
9.41
2.66
8.90
2.88
8.69
2.98
8.32
3.15
8.11
3.26
7.37
2.67
10.22 2.67
9.99
2.76
9.45
2.98
9.22
3.08
8.84
3.26
8.55
3.27
7.71
2.67
10.55 2.87
10.31 2.96
9.75
3.20
9.51
3.31
9.12
3.51
8.70
3.27
7.88
2.67
10.03 2.89
9.80
2.98
9.27
3.22
9.04
3.33
8.67
3.53
8.31
3.27
7.57
2.67
10.55 2.93
10.31 3.03
9.75
3.27
9.51
3.38
9.12
3.58
8.69
3.27
7.88
2.67
10.43 3.00
10.20 3.10
9.65
3.35
9.41
3.47
9.02
3.67
8.60
3.27
7.82
2.67

NOTE:

TC

: Total capacity

(kW)

PI

: Power input

(kW)

Capacities are based on the following conditions.


Corresponding refrigerant piping length : 7.5m
Level difference : 0m
3D055091
3D055092
3D055093
3D055094

88

SUPER MULTI NX E-Series Heat Pump

EDAU12-722

Capacity Tables

[Heating Capacity 50Hz 240V]


Combination
(Capacity)
2.0

2.5

3.5

5.0

6.0

2.0+2.0

2.0+2.5

2.0+3.5

2.0+5.0

2.0+6.0

2.5+2.5

Indoor
air temp.
CDB
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0

SUPER MULTI NX E-Series Heat Pump

-15C
TC
PI
kW
kW
2.15 1.00
2.09 1.01
2.04 1.02
2.01 1.02
1.99 1.03
1.93 1.04
2.27 1.08
2.22 1.09
2.16 1.10
2.13 1.11
2.10 1.11
2.05 1.12
2.47 1.26
2.41 1.28
2.35 1.29
2.32 1.30
2.29 1.30
2.23 1.32
4.44 2.19
4.33 2.22
4.22 2.24
4.16 2.25
4.11 2.27
3.99 2.29
4.71 2.19
4.59 2.22
4.47 2.24
4.42 2.25
4.36 2.27
4.24 2.29
4.23 1.78
4.13 1.80
4.02 1.82
3.97 1.83
3.92 1.84
3.81 1.86
4.33 1.85
4.22 1.87
4.11 1.89
4.06 1.90
4.00 1.91
3.90 1.94
4.62 2.08
4.51 2.10
4.39 2.13
4.33 2.14
4.27 2.15
4.16 2.17
5.60 2.34
5.46 2.36
5.32 2.39
5.25 2.40
5.18 2.42
5.04 2.44
5.71 2.36
5.57 2.39
5.43 2.41
5.35 2.43
5.28 2.44
5.14 2.47
4.50 2.02
4.39 2.05
4.28 2.07
4.22 2.08
4.17 2.09
4.05 2.11

-10C
TC
PI
kW
kW
2.59 1.05
2.53 1.06
2.48 1.07
2.45 1.07
2.42 1.08
2.37 1.09
2.74 1.13
2.68 1.14
2.62 1.15
2.60 1.16
2.57 1.17
2.51 1.18
2.98 1.33
2.92 1.34
2.85 1.35
2.82 1.36
2.79 1.37
2.73 1.38
5.34 2.30
5.23 2.33
5.12 2.35
5.07 2.37
5.01 2.38
4.90 2.40
5.67 2.30
5.55 2.33
5.44 2.35
5.38 2.37
5.32 2.38
5.20 2.40
5.10 1.87
4.99 1.89
4.89 1.91
4.83 1.92
4.78 1.93
4.67 1.95
5.21 1.95
5.10 1.97
4.99 1.99
4.94 2.00
4.89 2.01
4.78 2.03
5.56 2.19
5.45 2.21
5.33 2.23
5.28 2.24
5.22 2.25
5.10 2.28
6.74 2.46
6.60 2.48
6.46 2.51
6.39 2.52
6.32 2.54
6.18 2.56
6.88 2.48
6.73 2.51
6.59 2.54
6.52 2.55
6.45 2.56
6.31 2.59
5.42 2.13
5.31 2.15
5.20 2.17
5.14 2.18
5.09 2.19
4.97 2.22

Outdoor air temp.:CWB


-5C
0C
6C
TC
PI
TC
PI
TC
PI
kW
kW
kW
kW
kW
kW
3.02 1.10 3.46 1.15 3.99 1.21
2.97 1.11 3.41 1.16 3.93 1.22
2.92 1.12 3.35 1.17 3.88 1.23
2.89 1.12 3.33 1.17 3.85 1.24
2.86 1.13 3.30 1.18 3.83 1.24
2.81 1.14 3.25 1.19 3.77 1.25
3.20 1.19 3.67 1.24 4.22 1.31
3.15 1.20 3.61 1.25 4.17 1.32
3.09 1.21 3.55 1.26 4.11 1.33
3.06 1.22 3.52 1.27 4.08 1.34
3.03 1.22 3.50 1.28 4.05 1.34
2.98 1.23 3.44 1.29 4.00 1.35
3.48 1.39 3.99 1.45 4.59 1.53
3.42 1.40 3.93 1.47 4.53 1.55
3.36 1.42 3.86 1.48 4.47 1.56
3.33 1.43 3.83 1.49 4.44 1.57
3.30 1.43 3.80 1.50 4.41 1.57
3.24 1.45 3.74 1.51 4.35 1.59
6.25 2.42 7.15 2.53 8.24 2.66
6.14 2.44 7.04 2.55 8.13 2.69
6.03 2.46 6.93 2.58 8.02 2.71
5.97 2.48 6.88 2.59 7.96 2.72
5.92 2.49 6.82 2.60 7.91 2.73
5.81 2.51 6.71 2.62 7.69 2.68
6.63 2.42 7.59 2.53 8.74 2.66
6.51 2.44 7.47 2.55 8.63 2.69
6.40 2.46 7.36 2.58 8.51 2.71
6.34 2.48 7.30 2.59 8.45 2.72
6.28 2.49 7.24 2.60 8.39 2.73
6.16 2.51 7.12 2.62 8.28 2.76
5.96 1.96 6.82 2.05 7.86 2.16
5.86 1.98 6.72 2.07 7.76 2.18
5.75 2.00 6.61 2.09 7.65 2.20
5.70 2.01 6.56 2.10 7.60 2.21
5.64 2.02 6.51 2.11 7.54 2.22
5.54 2.04 6.40 2.13 7.44 2.24
6.09 2.04 6.98 2.14 8.04 2.25
5.99 2.06 6.87 2.16 7.93 2.27
5.88 2.08 6.76 2.18 7.82 2.29
5.82 2.09 6.71 2.19 7.77 2.30
5.77 2.10 6.65 2.20 7.71 2.31
5.66 2.12 6.54 2.22 7.60 2.33
6.51 2.29 7.45 2.40 8.58 2.52
6.39 2.31 7.33 2.42 8.47 2.55
6.28 2.34 7.22 2.44 8.35 2.57
6.22 2.35 7.16 2.45 8.29 2.58
6.16 2.36 7.10 2.47 8.23 2.59
6.05 2.38 6.99 2.49 8.12 2.62
7.89 2.58 9.03 2.70 10.40 2.84
7.75 2.60 8.89 2.72 10.26 2.86
7.61 2.63 8.75 2.75 10.12 2.89
7.54 2.64 8.68 2.76 10.05 2.90
7.47 2.65 8.61 2.77 9.98 2.92
7.33 2.68 8.47 2.80 9.84 2.94
8.04 2.60 9.21 2.72 10.60 2.87
7.90 2.63 9.06 2.75 10.46 2.89
7.76 2.66 8.92 2.78 10.32 2.92
7.69 2.67 8.85 2.79 10.25 2.93
7.61 2.68 8.78 2.80 10.18 2.95
7.47 2.71 8.64 2.83 10.04 2.97
6.34 2.23 7.26 2.33 8.36 2.45
6.23 2.25 7.15 2.35 8.25 2.48
6.12 2.27 7.04 2.38 8.14 2.50
6.06 2.28 6.98 2.39 8.08 2.51
6.01 2.30 6.92 2.40 8.03 2.52
5.89 2.32 6.81 2.42 7.92 2.55

10C
TC
PI
kW
kW
4.34 1.25
4.28 1.26
4.23 1.27
4.20 1.28
4.18 1.28
4.12 1.29
4.59 1.35
4.54 1.36
4.48 1.37
4.45 1.38
4.42 1.39
4.37 1.40
5.00 1.58
4.94 1.60
4.87 1.61
4.84 1.62
4.81 1.63
4.75 1.64
8.97 2.75
8.86 2.77
8.61 2.71
8.38 2.61
8.15 2.51
7.69 2.32
9.51 2.75
9.40 2.77
9.28 2.80
9.06 2.71
8.81 2.61
8.32 2.41
8.55 2.23
8.45 2.25
8.34 2.27
8.29 2.28
8.24 2.29
8.13 2.31
8.74 2.32
8.63 2.34
8.53 2.37
8.47 2.38
8.42 2.39
8.31 2.41
9.33 2.61
9.22 2.63
9.10 2.65
9.05 2.67
8.99 2.68
8.87 2.70
11.31 2.93
11.17 2.96
11.03 2.99
10.96 3.00
10.89 3.01
10.75 3.04
11.54 2.96
11.39 2.99
11.25 3.02
11.18 3.03
11.11 3.04
10.97 3.07
9.10 2.54
8.99 2.56
8.88 2.58
8.82 2.59
8.76 2.60
8.65 2.63

15C
TC
PI
kW
kW
4.78 1.30
4.72 1.31
4.67 1.32
4.64 1.33
4.62 1.33
4.56 1.34
5.06 1.40
5.00 1.42
4.95 1.43
4.92 1.43
4.89 1.44
4.83 1.45
5.50 1.65
5.44 1.66
5.38 1.68
5.35 1.68
5.32 1.69
5.03 1.58
9.53 2.66
9.07 2.49
8.61 2.32
8.38 2.24
8.15 2.16
7.69 2.00
10.30 2.76
9.81 2.58
9.31 2.40
9.06 2.31
8.81 2.23
8.32 2.06
9.42 2.32
9.31 2.34
9.20 2.36
9.15 2.37
9.10 2.38
8.99 2.40
9.63 2.42
9.52 2.44
9.41 2.46
9.36 2.47
9.30 2.48
9.19 2.50
10.28 2.71
10.16 2.74
10.05 2.76
9.99 2.77
9.93 2.78
9.82 2.81
12.46 3.05
12.32 3.08
12.18 3.10
12.11 3.12
12.04 3.13
11.90 3.16
12.70 3.08
12.56 3.11
12.42 3.14
12.35 3.15
12.28 3.16
12.13 3.19
10.02 2.64
9.91 2.66
9.79 2.69
9.74 2.70
9.68 2.71
9.57 2.73

89

Capacity Tables

Combination
(Capacity)
2.5+3.5

2.5+5.0

2.5+6.0

3.5+3.5

3.5+5.0

3.5+6.0

5.0+5.0

5.0+6.0

2.0+2.0+2.0

2.0+2.0+2.5

2.0+2.0+3.5

90

EDAU12-722

Indoor
air temp.
CDB
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0

-15C
TC
PI
kW
kW
4.77 2.27
4.65 2.29
4.53 2.32
4.47 2.33
4.41 2.34
4.29 2.37
5.66 2.37
5.52 2.40
5.38 2.42
5.31 2.44
5.24 2.45
5.10 2.48
5.75 2.37
5.61 2.40
5.47 2.42
5.40 2.44
5.32 2.45
5.18 2.48
4.96 2.45
4.84 2.48
4.72 2.51
4.65 2.52
4.59 2.53
4.47 2.56
5.76 2.44
5.62 2.46
5.47 2.49
5.40 2.50
5.33 2.52
5.19 2.54
5.84 2.36
5.70 2.39
5.55 2.41
5.48 2.43
5.41 2.44
5.26 2.47
5.87 2.27
5.72 2.29
5.58 2.32
5.50 2.33
5.43 2.34
5.29 2.37
5.89 2.22
5.74 2.24
5.59 2.27
5.52 2.28
5.45 2.29
5.30 2.32
5.55 2.14
5.41 2.16
5.27 2.18
5.20 2.20
5.13 2.21
5.00 2.23
5.60 2.17
5.46 2.19
5.32 2.22
5.25 2.23
5.18 2.24
5.04 2.26
5.64 2.27
5.50 2.29
5.36 2.32
5.29 2.33
5.22 2.34
5.08 2.37

-10C
TC
PI
kW
kW
5.74 2.38
5.62 2.41
5.51 2.43
5.45 2.44
5.39 2.46
5.27 2.48
6.82 2.49
6.67 2.52
6.53 2.54
6.46 2.56
6.39 2.57
6.25 2.60
6.93 2.49
6.79 2.52
6.64 2.54
6.57 2.56
6.50 2.57
6.35 2.60
5.98 2.58
5.85 2.60
5.73 2.63
5.67 2.64
5.60 2.66
5.48 2.69
6.94 2.56
6.79 2.59
6.65 2.61
6.58 2.63
6.50 2.64
6.36 2.67
7.04 2.48
6.89 2.51
6.74 2.54
6.67 2.55
6.60 2.56
6.45 2.59
7.07 2.38
6.92 2.41
6.78 2.43
6.70 2.44
6.63 2.46
6.48 2.48
7.09 2.33
6.94 2.35
6.80 2.38
6.72 2.39
6.65 2.40
6.50 2.43
6.68 2.24
6.54 2.27
6.41 2.29
6.34 2.30
6.27 2.32
6.13 2.34
6.74 2.28
6.60 2.30
6.46 2.33
6.39 2.34
6.32 2.35
6.18 2.38
6.80 2.38
6.66 2.41
6.51 2.43
6.44 2.44
6.37 2.46
6.23 2.48

Outdoor air temp.:CWB


-5C
0C
6C
TC
PI
TC
PI
TC
PI
kW
kW
kW
kW
kW
kW
6.72 2.50 7.69 2.61 8.86 2.75
6.60 2.52 7.57 2.64 8.74 2.77
6.48 2.55 7.45 2.66 8.62 2.80
6.42 2.56 7.39 2.67 8.56 2.81
6.36 2.57 7.33 2.69 8.50 2.83
6.24 2.60 7.21 2.71 8.38 2.85
7.97 2.61 9.13 2.73 10.51 2.88
7.83 2.64 8.99 2.76 10.37 2.90
7.69 2.66 8.84 2.79 10.23 2.93
7.62 2.68 8.77 2.80 10.16 2.94
7.55 2.69 8.70 2.81 10.09 2.96
7.41 2.72 8.56 2.84 9.95 2.98
8.10 2.61 9.28 2.73 10.69 2.88
7.96 2.64 9.13 2.76 10.54 2.90
7.82 2.66 8.99 2.79 10.40 2.93
7.74 2.68 8.92 2.80 10.33 2.94
7.67 2.69 8.85 2.81 10.26 2.96
7.53 2.72 8.70 2.84 10.11 2.98
6.99 2.70 8.00 2.83 9.22 2.98
6.87 2.73 7.88 2.85 9.09 3.00
6.74 2.76 7.75 2.88 8.97 3.03
6.68 2.77 7.69 2.89 8.91 3.04
6.62 2.78 7.63 2.91 8.85 3.06
6.49 2.81 7.51 2.93 8.72 3.08
8.11 2.68 9.29 2.81 10.70 2.96
7.97 2.71 9.14 2.83 10.55 2.98
7.82 2.74 9.00 2.86 10.41 3.01
7.75 2.75 8.93 2.87 10.34 3.02
7.68 2.76 8.86 2.89 10.27 3.04
7.54 2.79 8.71 2.92 10.12 3.06
8.23 2.60 9.42 2.72 10.85 2.87
8.08 2.63 9.27 2.75 10.71 2.89
7.94 2.66 9.13 2.78 10.56 2.92
7.86 2.67 9.06 2.79 10.49 2.93
7.79 2.68 8.98 2.80 10.41 2.95
7.65 2.71 8.84 2.83 10.27 2.97
8.27 2.50 9.47 2.61 10.90 2.75
8.12 2.52 9.32 2.64 10.76 2.77
7.97 2.55 9.17 2.66 10.61 2.80
7.90 2.56 9.10 2.67 10.54 2.81
7.83 2.57 9.03 2.69 10.46 2.83
7.68 2.60 8.88 2.71 10.32 2.85
8.29 2.44 9.49 2.56 10.93 2.69
8.14 2.47 9.35 2.58 10.79 2.72
8.00 2.49 9.20 2.60 10.64 2.74
7.92 2.50 9.12 2.62 10.57 2.75
7.85 2.52 9.05 2.63 10.49 2.76
7.70 2.54 8.90 2.65 10.35 2.79
7.82 2.35 8.95 2.46 10.31 2.59
7.68 2.38 8.81 2.49 10.17 2.62
7.54 2.40 8.67 2.51 10.03 2.64
7.47 2.41 8.60 2.52 9.96 2.65
7.40 2.42 8.53 2.53 9.89 2.66
7.26 2.45 8.39 2.56 9.75 2.69
7.89 2.39 9.03 2.50 10.40 2.63
7.75 2.41 8.89 2.52 10.26 2.66
7.61 2.44 8.75 2.55 10.12 2.68
7.54 2.45 8.68 2.56 10.05 2.69
7.47 2.46 8.61 2.57 9.98 2.70
7.33 2.49 8.47 2.60 9.84 2.73
7.95 2.50 9.10 2.61 10.48 2.75
7.81 2.52 8.96 2.64 10.34 2.77
7.67 2.55 8.82 2.66 10.20 2.80
7.60 2.56 8.75 2.67 10.13 2.81
7.53 2.57 8.68 2.69 10.06 2.83
7.38 2.60 8.54 2.71 9.92 2.85

10C
TC
PI
kW
kW
9.64 2.84
9.52 2.87
9.40 2.89
9.34 2.90
9.28 2.92
9.16 2.94
11.44 2.97
11.30 3.00
11.15 3.03
11.08 3.04
11.01 3.05
10.87 3.08
11.63 2.97
11.48 3.00
11.34 3.03
11.27 3.04
11.20 3.05
11.05 3.08
10.03 3.08
9.90 3.10
9.78 3.13
9.72 3.14
9.66 3.16
9.53 3.18
11.64 3.05
11.49 3.08
11.35 3.11
11.28 3.12
11.21 3.14
11.06 3.16
11.81 2.96
11.66 2.99
11.51 3.02
11.44 3.03
11.37 3.04
11.22 3.07
11.86 2.84
11.71 2.87
11.57 2.89
11.50 2.90
11.42 2.92
11.28 2.94
11.89 2.78
11.75 2.81
11.60 2.83
11.53 2.84
11.45 2.85
11.31 2.88
11.21 2.68
11.07 2.70
10.94 2.73
10.87 2.74
10.80 2.75
10.66 2.77
11.31 2.72
11.17 2.74
11.03 2.77
10.96 2.78
10.89 2.79
10.75 2.82
11.40 2.84
11.26 2.87
11.12 2.89
11.05 2.90
10.98 2.92
10.84 2.94

15C
TC
PI
kW
kW
10.61 2.96
10.49 2.98
10.37 3.01
10.31 3.02
10.25 3.03
9.90 2.91
12.59 3.09
12.45 3.12
12.31 3.15
12.24 3.16
12.17 3.17
12.03 3.20
12.80 3.09
12.66 3.12
12.51 3.15
12.44 3.16
12.37 3.17
12.23 3.20
11.04 3.20
10.92 3.23
10.79 3.25
10.73 3.27
10.66 3.27
10.06 2.98
12.81 3.18
12.67 3.21
12.53 3.23
12.45 3.25
12.38 3.26
12.24 3.29
13.00 3.08
12.85 3.11
12.71 3.14
12.63 3.15
12.56 3.16
12.41 3.19
13.06 2.96
12.91 2.98
12.77 3.01
12.69 3.02
12.62 3.03
12.47 3.06
13.10 2.89
12.95 2.92
12.80 2.94
12.73 2.96
12.66 2.97
12.51 2.99
12.35 2.79
12.21 2.81
12.07 2.84
12.00 2.85
11.93 2.86
11.79 2.88
12.46 2.83
12.32 2.85
12.18 2.88
12.11 2.89
12.04 2.90
11.90 2.93
12.55 2.96
12.41 2.98
12.27 3.01
12.20 3.02
12.13 3.03
11.99 3.06

SUPER MULTI NX E-Series Heat Pump

EDAU12-722

Combination
(Capacity)
2.0+2.0+5.0

2.0+2.0+6.0

2.0+2.5+2.5

2.0+2.5+3.5

2.0+2.5+5.0

2.0+2.5+6.0

2.0+3.5+3.5

2.0+3.5+5.0

2.5+2.5+2.5

2.5+2.5+3.5

2.5+2.5+5.0

Capacity Tables

Indoor
air temp.
CDB
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0

SUPER MULTI NX E-Series Heat Pump

-15C
TC
PI
kW
kW
5.79 2.12
5.65 2.14
5.50 2.17
5.43 2.18
5.36 2.19
5.22 2.21
5.87 2.11
5.72 2.14
5.57 2.16
5.50 2.17
5.43 2.18
5.28 2.21
5.60 2.21
5.46 2.23
5.32 2.26
5.25 2.27
5.18 2.28
5.04 2.31
5.64 2.27
5.50 2.29
5.36 2.32
5.29 2.33
5.22 2.34
5.08 2.37
5.87 2.14
5.72 2.17
5.58 2.19
5.50 2.20
5.43 2.22
5.29 2.24
5.89 2.08
5.74 2.10
5.59 2.13
5.52 2.14
5.45 2.15
5.30 2.17
5.76 2.30
5.62 2.32
5.47 2.35
5.40 2.36
5.33 2.37
5.19 2.40
5.89 2.20
5.74 2.23
5.59 2.25
5.52 2.26
5.45 2.27
5.30 2.30
5.66 2.27
5.52 2.29
5.38 2.32
5.31 2.33
5.24 2.34
5.10 2.37
5.76 2.33
5.62 2.36
5.47 2.38
5.40 2.39
5.33 2.41
5.19 2.43
5.87 2.17
5.72 2.19
5.58 2.22
5.50 2.23
5.43 2.24
5.29 2.26

-10C
TC
PI
kW
kW
6.98 2.23
6.83 2.25
6.69 2.27
6.61 2.29
6.54 2.30
6.40 2.32
7.06 2.22
6.92 2.24
6.77 2.27
6.70 2.28
6.62 2.29
6.48 2.31
6.74 2.32
6.60 2.35
6.46 2.37
6.39 2.38
6.32 2.39
6.18 2.42
6.80 2.38
6.66 2.41
6.51 2.43
6.44 2.44
6.37 2.46
6.23 2.48
7.07 2.25
6.92 2.28
6.78 2.30
6.70 2.31
6.63 2.32
6.48 2.35
7.09 2.19
6.94 2.21
6.80 2.23
6.72 2.24
6.65 2.25
6.50 2.28
6.94 2.41
6.79 2.44
6.65 2.47
6.58 2.48
6.50 2.49
6.36 2.52
7.09 2.31
6.94 2.34
6.80 2.36
6.72 2.37
6.65 2.39
6.50 2.41
6.82 2.38
6.67 2.41
6.53 2.43
6.46 2.44
6.39 2.46
6.25 2.48
6.94 2.45
6.79 2.47
6.65 2.50
6.58 2.51
6.50 2.53
6.36 2.55
7.07 2.28
6.92 2.30
6.78 2.33
6.70 2.34
6.63 2.35
6.48 2.38

Outdoor air temp.:CWB


-5C
0C
6C
TC
PI
TC
PI
TC
PI
kW
kW
kW
kW
kW
kW
8.16 2.34 9.34 2.44 10.76 2.57
8.01 2.36 9.20 2.47 10.61 2.60
7.87 2.38 9.05 2.49 10.47 2.62
7.80 2.39 8.98 2.50 10.40 2.63
7.72 2.41 8.91 2.51 10.33 2.64
7.58 2.43 8.76 2.54 10.18 2.67
8.26 2.33 9.46 2.43 10.89 2.56
8.11 2.35 9.31 2.46 10.75 2.59
7.97 2.37 9.16 2.48 10.60 2.61
7.89 2.39 9.09 2.49 10.53 2.62
7.82 2.40 9.02 2.50 10.45 2.63
7.67 2.42 8.87 2.53 10.31 2.66
7.89 2.43 9.03 2.55 10.40 2.68
7.75 2.46 8.89 2.57 10.26 2.71
7.61 2.48 8.75 2.60 10.12 2.73
7.54 2.49 8.68 2.61 10.05 2.74
7.47 2.51 8.61 2.62 9.98 2.75
7.33 2.53 8.47 2.64 9.84 2.78
7.95 2.50 9.10 2.61 10.48 2.75
7.81 2.52 8.96 2.64 10.34 2.77
7.67 2.55 8.82 2.66 10.20 2.80
7.60 2.56 8.75 2.67 10.13 2.81
7.53 2.57 8.68 2.69 10.06 2.83
7.38 2.60 8.54 2.71 9.92 2.85
8.27 2.36 9.47 2.47 10.90 2.60
8.12 2.39 9.32 2.50 10.76 2.63
7.97 2.41 9.17 2.52 10.61 2.65
7.90 2.42 9.10 2.53 10.54 2.66
7.83 2.43 9.03 2.54 10.46 2.67
7.68 2.46 8.88 2.57 10.32 2.70
8.29 2.29 9.49 2.40 10.93 2.52
8.14 2.31 9.35 2.42 10.79 2.55
8.00 2.34 9.20 2.44 10.64 2.57
7.92 2.35 9.12 2.45 10.57 2.58
7.85 2.36 9.05 2.47 10.49 2.59
7.70 2.38 8.90 2.49 10.35 2.62
8.11 2.53 9.29 2.65 10.70 2.79
7.97 2.56 9.14 2.67 10.55 2.81
7.82 2.58 9.00 2.70 10.41 2.84
7.75 2.60 8.93 2.71 10.34 2.85
7.68 2.61 8.86 2.73 10.27 2.87
7.54 2.63 8.71 2.75 10.12 2.89
8.29 2.42 9.49 2.54 10.93 2.67
8.14 2.45 9.35 2.56 10.79 2.70
8.00 2.47 9.20 2.59 10.64 2.72
7.92 2.49 9.12 2.60 10.57 2.73
7.85 2.50 9.05 2.61 10.49 2.74
7.70 2.52 8.90 2.63 10.35 2.77
7.97 2.50 9.13 2.61 10.51 2.75
7.83 2.52 8.99 2.64 10.37 2.77
7.69 2.55 8.84 2.66 10.23 2.80
7.62 2.56 8.77 2.67 10.16 2.81
7.55 2.57 8.70 2.69 10.09 2.83
7.41 2.60 8.56 2.71 9.95 2.85
8.11 2.57 9.29 2.69 10.70 2.83
7.97 2.59 9.14 2.71 10.55 2.85
7.82 2.62 9.00 2.74 10.41 2.88
7.75 2.63 8.93 2.75 10.34 2.89
7.68 2.65 8.86 2.76 10.27 2.91
7.54 2.67 8.71 2.79 10.12 2.93
8.27 2.39 9.47 2.50 10.90 2.63
8.12 2.41 9.32 2.52 10.76 2.66
7.97 2.44 9.17 2.55 10.61 2.68
7.90 2.45 9.10 2.56 10.54 2.69
7.83 2.46 9.03 2.57 10.46 2.70
7.68 2.49 8.88 2.60 10.32 2.73

10C
TC
PI
kW
kW
11.70 2.66
11.56 2.68
11.42 2.71
11.34 2.72
11.27 2.73
11.13 2.75
11.85 2.65
11.70 2.67
11.56 2.70
11.48 2.71
11.41 2.72
11.26 2.74
11.31 2.77
11.17 2.80
11.03 2.82
10.96 2.83
10.89 2.84
10.75 2.87
11.40 2.84
11.26 2.87
11.12 2.89
11.05 2.90
10.98 2.92
10.84 2.94
11.86 2.69
11.71 2.71
11.57 2.74
11.50 2.75
11.42 2.76
11.28 2.79
11.89 2.61
11.75 2.63
11.60 2.65
11.53 2.67
11.45 2.68
11.31 2.70
11.64 2.88
11.49 2.91
11.35 2.93
11.28 2.95
11.21 2.96
11.06 2.98
11.89 2.76
11.75 2.79
11.60 2.81
11.53 2.82
11.45 2.83
11.31 2.86
11.44 2.84
11.30 2.87
11.15 2.89
11.08 2.90
11.01 2.92
10.87 2.94
11.64 2.92
11.49 2.95
11.35 2.97
11.28 2.99
11.21 3.00
11.06 3.03
11.86 2.72
11.71 2.74
11.57 2.77
11.50 2.78
11.42 2.79
11.28 2.82

15C
TC
PI
kW
kW
12.89 2.77
12.74 2.79
12.60 2.81
12.53 2.83
12.45 2.84
12.31 2.86
13.05 2.76
12.90 2.78
12.75 2.80
12.68 2.82
12.61 2.83
12.46 2.85
12.46 2.88
12.32 2.91
12.18 2.93
12.11 2.94
12.04 2.96
11.90 2.98
12.55 2.96
12.41 2.98
12.27 3.01
12.20 3.02
12.13 3.03
11.99 3.06
13.06 2.80
12.91 2.82
12.77 2.85
12.69 2.86
12.62 2.87
12.47 2.89
13.10 2.71
12.95 2.74
12.80 2.76
12.73 2.77
12.66 2.78
12.51 2.81
12.81 3.00
12.67 3.02
12.53 3.05
12.45 3.06
12.38 3.08
12.24 3.10
13.10 2.87
12.95 2.90
12.80 2.92
12.73 2.93
12.66 2.95
12.51 2.97
12.59 2.96
12.45 2.98
12.31 3.01
12.24 3.02
12.17 3.03
12.03 3.06
12.81 3.04
12.67 3.07
12.53 3.09
12.45 3.11
12.38 3.12
12.24 3.15
13.06 2.83
12.91 2.85
12.77 2.88
12.69 2.89
12.62 2.90
12.47 2.93

91

Capacity Tables

Combination
(Capacity)
2.5+2.5+6.0

2.5+3.5+3.5

2.5+3.5+5.0

3.5+3.5+3.5

Symbols
TC
: Total capacity
PI
: Power input

EDAU12-722

Indoor
air temp.
CDB
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
16.0
18.0
20.0
21.0
22.0
24.0
(kW)
(kW)

-15C
TC
PI
kW
kW
5.89 2.09
5.74 2.11
5.59 2.13
5.52 2.15
5.45 2.16
5.30 2.18
5.84 2.33
5.70 2.36
5.55 2.38
5.48 2.39
5.41 2.41
5.26 2.43
5.89 2.16
5.74 2.18
5.59 2.21
5.52 2.22
5.45 2.23
5.30 2.26
5.88 2.38
5.73 2.41
5.58 2.43
5.51 2.44
5.44 2.46
5.29 2.48

-10C
TC
PI
kW
kW
7.09 2.19
6.94 2.22
6.80 2.24
6.72 2.25
6.65 2.26
6.50 2.29
7.04 2.45
6.89 2.47
6.74 2.50
6.67 2.51
6.60 2.53
6.45 2.55
7.09 2.27
6.94 2.29
6.80 2.32
6.72 2.33
6.65 2.34
6.50 2.37
7.08 2.50
6.93 2.53
6.78 2.55
6.71 2.57
6.64 2.58
6.49 2.61

Outdoor air temp.:CWB


-5C
0C
6C
TC
PI
TC
PI
TC
PI
kW
kW
kW
kW
kW
kW
8.29 2.30 9.49 2.41 10.93 2.53
8.14 2.32 9.35 2.43 10.79 2.56
8.00 2.35 9.20 2.45 10.64 2.58
7.92 2.36 9.12 2.46 10.57 2.59
7.85 2.37 9.05 2.48 10.49 2.60
7.70 2.39 8.90 2.50 10.35 2.63
8.23 2.57 9.42 2.69 10.85 2.83
8.08 2.59 9.27 2.71 10.71 2.85
7.94 2.62 9.13 2.74 10.56 2.88
7.86 2.63 9.06 2.75 10.49 2.89
7.79 2.65 8.98 2.76 10.41 2.91
7.65 2.67 8.84 2.79 10.27 2.93
8.29 2.38 9.49 2.49 10.93 2.62
8.14 2.40 9.35 2.51 10.79 2.65
8.00 2.43 9.20 2.54 10.64 2.67
7.92 2.44 9.12 2.55 10.57 2.68
7.85 2.45 9.05 2.56 10.49 2.69
7.70 2.48 8.90 2.59 10.35 2.72
8.28 2.62 9.47 2.74 10.91 2.89
8.13 2.65 9.33 2.77 10.77 2.91
7.98 2.67 9.18 2.79 10.62 2.94
7.91 2.69 9.11 2.81 10.55 2.95
7.84 2.70 9.03 2.82 10.47 2.97
7.69 2.73 8.89 2.85 10.33 2.99

10C
TC
PI
kW
kW
11.89 2.62
11.75 2.64
11.60 2.66
11.53 2.68
11.45 2.69
11.31 2.71
11.81 2.92
11.66 2.95
11.51 2.97
11.44 2.99
11.37 3.00
11.22 3.03
11.89 2.71
11.75 2.73
11.60 2.76
11.53 2.77
11.45 2.78
11.31 2.81
11.87 2.98
11.73 3.01
11.58 3.04
11.51 3.05
11.43 3.06
11.29 3.09

15C
TC
PI
kW
kW
13.10 2.72
12.95 2.75
12.80 2.77
12.73 2.78
12.66 2.79
12.51 2.82
13.00 3.04
12.85 3.07
12.71 3.09
12.63 3.11
12.56 3.12
12.41 3.15
13.10 2.82
12.95 2.84
12.80 2.87
12.73 2.88
12.66 2.89
12.51 2.92
13.07 3.10
12.93 3.13
12.78 3.16
12.71 3.17
12.63 3.18
12.49 3.21

NOTE:
Capacities are based on the following conditions.
Corresponding refrigerant piping length : 7.5m
Level difference : 0m
3D055098
3D055099
3D055100

92

SUPER MULTI NX E-Series Heat Pump

EDAU12-722

7.1.3

Capacity Tables

4MXS80EVMA

[Cooling Capacity 50Hz / 60Hz 220V]


Combination
(Capacity)
2.0

2.5

3.5

5.0

6.0

7.1

2.0+2.0

2.0+2.5

2.0+3.5

Outdoor
air temp.
CDB
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0

SUPER MULTI NX E-Series Heat Pump

14C
TC
PI
kW
kW
3.01
0.88
2.92
0.91
2.73
0.99
2.65
1.03
2.51
1.09
2.42
1.14
2.34
1.18
3.22
0.97
3.22
1.04
3.21
1.25
3.11
1.30
2.95
1.38
2.85
1.43
2.75
1.49
3.29
0.74
3.29
0.79
3.29
0.93
3.29
1.01
3.29
1.15
3.29
1.25
3.29
1.37
5.15
1.27
5.15
1.38
5.15
1.67
5.00
1.74
4.74
1.85
4.58
1.92
4.42
1.99
5.60
1.49
5.60
1.61
5.60
1.96
5.60
2.15
5.53
2.48
5.35
2.58
5.16
2.68
6.01
1.62
6.01
1.76
6.01
2.15
6.01
2.36
6.01
2.81
5.88
3.00
5.66
2.90
5.33
1.37
5.18
1.42
4.84
1.55
4.69
1.60
4.44
1.71
4.29
1.77
4.15
1.84
5.76
1.49
5.60
1.54
5.23
1.68
5.07
1.74
4.80
1.85
4.64
1.92
4.48
1.99
6.42
1.73
6.24
1.80
5.82
1.95
5.65
2.03
5.35
2.16
5.17
2.24
4.99
2.33

16C
TC
PI
kW
kW
3.15
0.90
3.06
0.93
2.87
1.01
2.78
1.05
2.64
1.11
2.56
1.15
2.48
1.20
3.70
1.13
3.60
1.17
3.38
1.27
3.28
1.32
3.11
1.40
3.01
1.45
2.92
1.51
4.04
0.93
4.04
1.00
4.04
1.19
4.04
1.29
4.04
1.48
4.04
1.62
4.02
1.76
5.94
1.52
5.79
1.57
5.42
1.71
5.26
1.77
5.00
1.88
4.84
1.95
4.68
2.02
6.88
2.00
6.76
2.11
6.33
2.29
6.14
2.37
5.84
2.52
5.65
2.62
5.47
2.72
7.38
2.21
7.38
2.42
6.96
2.67
6.76
2.77
6.42
2.94
6.22
3.05
5.97
2.90
5.58
1.40
5.43
1.45
5.08
1.57
4.93
1.63
4.69
1.73
4.54
1.80
4.39
1.87
6.03
1.52
5.87
1.57
5.49
1.71
5.33
1.77
5.07
1.88
4.91
1.95
4.75
2.02
6.71
1.77
6.53
1.83
6.12
1.99
5.94
2.06
5.64
2.19
5.46
2.27
5.29
2.36

Indoor air temp.:CWB


18C
19C
TC
PI
TC
PI
kW
kW
kW
kW
3.28
0.91
3.35
0.92
3.20
0.95
3.27
0.95
3.00
1.03
3.07
1.03
2.92
1.06
2.99
1.07
2.78
1.13
2.85
1.14
2.70
1.17
2.77
1.18
2.61
1.21
2.68
1.22
3.87
1.15
3.95
1.16
3.77
1.19
3.85
1.20
3.54
1.29
3.62
1.30
3.44
1.34
3.52
1.35
3.28
1.42
3.36
1.43
3.18
1.48
3.26
1.49
3.08
1.53
3.16
1.54
4.85
1.16
5.28
1.29
4.85
1.25
5.28
1.39
4.85
1.49
4.99
1.52
4.74
1.56
4.85
1.57
4.51
1.66
4.62
1.67
4.38
1.72
4.49
1.73
4.24
1.78
4.35
1.79
6.20
1.55
6.33
1.56
6.05
1.60
6.18
1.61
5.68
1.73
5.81
1.75
5.52
1.80
5.65
1.81
5.26
1.91
5.39
1.92
5.10
1.98
5.23
1.99
4.94
2.05
5.07
2.07
7.25
2.07
7.40
2.09
7.06
2.15
7.21
2.17
6.63
2.33
6.78
2.35
6.45
2.41
6.60
2.43
6.14
2.56
6.29
2.58
5.96
2.66
6.11
2.68
5.77
2.76
5.92
2.77
7.97
2.42
8.14
2.44
7.77
2.50
7.94
2.52
7.30
2.71
7.46
2.73
7.09
2.81
7.26
2.83
6.75
2.98
6.92
3.01
6.55
3.09
6.72
3.12
6.27
2.90
6.42
2.90
5.82
1.43
5.94
1.44
5.67
1.48
5.79
1.49
5.33
1.60
5.45
1.61
5.18
1.66
5.30
1.67
4.93
1.76
5.05
1.77
4.78
1.83
4.91
1.84
4.63
1.89
4.76
1.91
6.29
1.55
6.42
1.56
6.13
1.60
6.26
1.61
5.76
1.73
5.89
1.75
5.60
1.80
5.73
1.81
5.33
1.91
5.46
1.92
5.17
1.98
5.30
1.99
5.01
2.05
5.14
2.07
7.01
1.80
7.15
1.82
6.83
1.86
6.97
1.88
6.41
2.02
6.56
2.04
6.23
2.10
6.38
2.11
5.94
2.22
6.08
2.24
5.76
2.31
5.90
2.32
5.58
2.39
5.73
2.41

22C
TC
PI
kW
kW
3.56
0.95
3.48
0.98
3.28
1.06
3.20
1.10
3.06
1.16
2.97
1.20
2.89
1.25
4.19
1.20
4.09
1.24
3.86
1.34
3.76
1.38
3.60
1.47
3.50
1.52
3.40
1.57
5.77
1.39
5.64
1.44
5.32
1.55
5.19
1.61
4.96
1.71
4.82
1.77
4.69
1.83
6.72
1.60
6.57
1.66
6.20
1.79
6.04
1.86
5.78
1.97
5.62
2.04
5.46
2.11
7.86
2.15
7.67
2.22
7.24
2.41
7.06
2.49
6.75
2.64
6.56
2.73
6.38
2.83
8.64
2.51
8.44
2.59
7.96
2.80
7.76
2.90
7.42
3.07
7.22
3.18
6.86
2.90
6.31
1.48
6.16
1.53
5.81
1.65
5.67
1.71
5.42
1.81
5.27
1.88
5.12
1.95
6.82
1.60
6.66
1.66
6.29
1.79
6.13
1.86
5.86
1.97
5.70
2.04
5.54
2.11
7.59
1.87
7.42
1.93
7.00
2.09
6.82
2.16
6.52
2.29
6.35
2.37
6.17
2.46

24C
TC
PI
kW
kW
3.70
0.96
3.61
1.00
3.42
1.08
3.33
1.11
3.20
1.18
3.11
1.22
3.03
1.26
4.35
1.22
4.25
1.26
4.02
1.36
3.93
1.41
3.76
1.49
3.66
1.54
3.56
1.60
6.00
1.42
5.86
1.46
5.54
1.58
5.41
1.63
5.18
1.73
5.05
1.79
4.91
1.86
6.98
1.63
6.83
1.69
6.46
1.82
6.30
1.88
6.04
2.00
5.88
2.07
5.72
2.14
8.16
2.19
7.97
2.26
7.54
2.45
7.36
2.53
7.05
2.68
6.87
2.77
6.68
2.87
8.98
2.55
8.77
2.64
8.30
2.85
8.10
2.95
7.76
3.12
7.56
3.23
7.15
2.90
6.55
1.51
6.40
1.56
6.06
1.68
5.91
1.74
5.66
1.84
5.52
1.91
5.37
1.97
7.08
1.63
6.92
1.69
6.55
1.82
6.39
1.88
6.12
2.00
5.96
2.07
5.80
2.14
7.89
1.90
7.71
1.97
7.29
2.12
7.11
2.20
6.82
2.33
6.64
2.41
6.46
2.49

93

Capacity Tables

Combination
(Capacity)
2.0+5.0

2.0+6.0

2.0+7.1

2.5+2.5

2.5+3.5

2.5+5.0

2.5+6.0

2.5+7.1

3.5+3.5

94

EDAU12-722

Outdoor
air temp.
CDB
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0

14C
TC
PI
kW
kW
7.34
2.08
7.14
2.15
6.66
2.34
6.46
2.43
6.12
2.59
5.92
2.69
5.71
2.79
7.95
2.43
7.73
2.52
7.21
2.74
6.99
2.84
6.62
3.03
6.40
3.14
6.12
2.90
8.27
2.60
8.04
2.69
7.50
2.93
7.27
3.04
6.89
3.23
6.66
3.35
6.37
2.90
6.21
1.73
6.03
1.80
5.63
1.95
5.46
2.03
5.17
2.16
5.00
2.24
4.83
2.33
6.51
1.88
6.45
2.02
6.02
2.20
5.84
2.28
5.53
2.42
5.35
2.52
5.16
2.61
7.63
2.28
7.42
2.36
6.93
2.57
6.72
2.66
6.36
2.83
6.15
2.94
5.91
2.90
8.08
2.49
7.85
2.58
7.33
2.81
7.11
2.91
6.73
3.10
6.51
3.22
6.22
2.90
8.27
2.60
8.04
2.69
7.50
2.93
7.27
3.04
6.89
3.23
6.66
3.35
6.37
2.90
6.59
1.91
6.59
2.07
6.59
2.58
6.43
2.72
6.09
2.89
5.89
3.00
5.67
2.90

16C
TC
PI
kW
kW
7.68
2.12
7.48
2.19
7.00
2.38
6.80
2.47
6.46
2.63
6.25
2.73
6.05
2.83
8.31
2.48
8.09
2.57
7.57
2.79
7.35
2.89
6.99
3.07
6.77
3.19
6.45
2.90
8.65
2.65
8.42
2.74
7.88
2.98
7.65
3.09
7.27
3.28
7.04
3.40
6.69
2.90
6.49
1.77
6.32
1.83
5.92
1.99
5.74
2.06
5.46
2.19
5.28
2.27
5.11
2.36
6.94
1.99
6.76
2.06
6.33
2.23
6.14
2.32
5.84
2.46
5.65
2.55
5.47
2.65
7.98
2.32
7.77
2.40
7.28
2.61
7.07
2.71
6.71
2.88
6.50
2.98
6.23
2.90
8.45
2.54
8.22
2.63
7.70
2.86
7.48
2.96
7.10
3.15
6.88
3.26
6.54
2.90
8.65
2.65
8.42
2.74
7.88
2.98
7.65
3.09
7.27
3.28
7.04
3.40
6.69
2.90
7.65
2.37
7.44
2.45
6.97
2.67
6.77
2.77
6.43
2.94
6.23
3.05
5.98
2.90

Indoor air temp.:CWB


18C
19C
TC
PI
TC
PI
kW
kW
kW
kW
8.02
2.16
8.18
2.18
7.81
2.23
7.98
2.26
7.34
2.42
7.50
2.44
7.13
2.51
7.30
2.53
6.79
2.67
6.96
2.69
6.59
2.77
6.76
2.79
6.38
2.87
6.55
2.89
8.67
2.53
8.86
2.55
8.45
2.61
8.64
2.64
7.94
2.84
8.12
2.86
7.72
2.94
7.90
2.96
7.35
3.12
7.53
3.14
7.13
3.24
7.31
3.26
6.76
2.90
6.92
2.90
9.03
2.70
9.22
2.72
8.80
2.79
8.99
2.82
8.26
3.03
8.45
3.05
8.03
3.14
8.22
3.16
7.65
3.33
7.84
3.36
7.42
3.44
7.60
3.44
7.01
2.90
7.16
2.90
6.77
1.80
6.92
1.82
6.60
1.86
6.74
1.88
6.20
2.02
6.34
2.04
6.03
2.10
6.17
2.11
5.74
2.22
5.88
2.24
5.57
2.31
5.71
2.32
5.40
2.39
5.54
2.41
7.25
2.02
7.40
2.04
7.06
2.09
7.21
2.11
6.63
2.27
6.78
2.29
6.45
2.35
6.60
2.37
6.14
2.50
6.29
2.52
5.96
2.59
6.11
2.61
5.77
2.69
5.92
2.71
8.33
2.37
8.51
2.39
8.12
2.45
8.30
2.47
7.63
2.65
7.80
2.68
7.42
2.75
7.59
2.77
7.06
2.92
7.24
2.94
6.85
3.03
7.02
3.05
6.55
2.90
6.70
2.90
8.82
2.59
9.00
2.61
8.59
2.68
8.78
2.70
8.07
2.90
8.25
2.93
7.85
3.01
8.03
3.03
7.47
3.20
7.66
3.22
7.25
3.31
7.43
3.34
6.86
2.90
7.01
2.90
9.03
2.70
9.22
2.72
8.80
2.79
8.99
2.82
8.26
3.03
8.45
3.05
8.03
3.14
8.22
3.16
7.65
3.33
7.84
3.36
7.42
3.44
7.60
3.44
7.01
2.90
7.16
2.90
7.98
2.42
8.15
2.44
7.78
2.50
7.95
2.52
7.31
2.71
7.47
2.73
7.10
2.81
7.27
2.83
6.76
2.98
6.93
3.01
6.56
3.09
6.73
3.12
6.28
2.90
6.43
2.90

22C
TC
PI
kW
kW
8.69
2.24
8.48
2.32
8.01
2.51
7.80
2.59
7.46
2.75
7.26
2.85
7.02
2.90
9.40
2.62
9.18
2.71
8.67
2.93
8.45
3.03
8.08
3.22
7.86
3.33
7.37
2.90
9.78
2.80
9.55
2.89
9.02
3.13
8.79
3.24
8.41
3.43
8.15
3.44
7.62
2.90
7.34
1.87
7.17
1.93
6.77
2.09
6.60
2.16
6.31
2.29
6.14
2.37
5.96
2.46
7.86
2.10
7.67
2.17
7.24
2.35
7.06
2.43
6.75
2.57
6.56
2.67
6.38
2.76
9.03
2.45
8.82
2.54
8.33
2.74
8.11
2.84
7.76
3.01
7.55
3.12
7.16
2.90
9.56
2.68
9.33
2.77
8.81
3.00
8.58
3.11
8.21
3.29
7.99
3.41
7.47
2.90
9.78
2.80
9.55
2.89
9.02
3.13
8.79
3.24
8.41
3.43
8.15
3.44
7.62
2.90
8.65
2.51
8.45
2.59
7.98
2.80
7.77
2.90
7.43
3.07
7.23
3.18
6.87
2.90

24C
TC
PI
kW
kW
9.02
2.28
8.82
2.36
8.34
2.55
8.14
2.63
7.80
2.79
7.60
2.89
7.33
2.90
9.77
2.67
9.55
2.76
9.03
2.98
8.81
3.08
8.44
3.26
8.22
3.38
7.67
2.90
10.16 2.85
9.93
2.94
9.40
3.18
9.17
3.29
8.78
3.48
8.50
3.44
7.91
2.90
7.63
1.90
7.46
1.97
7.05
2.12
6.88
2.20
6.59
2.33
6.42
2.41
6.25
2.49
8.16
2.14
7.97
2.21
7.54
2.38
7.36
2.47
7.05
2.61
6.87
2.71
6.68
2.80
9.38
2.50
9.17
2.58
8.68
2.79
8.46
2.88
8.11
3.05
7.90
3.16
7.46
2.90
9.93
2.73
9.70
2.82
9.18
3.05
8.95
3.15
8.58
3.34
8.35
3.44
7.77
2.90
10.16 2.85
9.93
2.94
9.40
3.18
9.17
3.29
8.78
3.48
8.50
3.44
7.91
2.90
8.99
2.55
8.78
2.64
8.31
2.85
8.11
2.95
7.77
3.12
7.57
3.23
7.16
2.90

SUPER MULTI NX E-Series Heat Pump

EDAU12-722

Combination
(Capacity)
3.5+5.0

3.5+6.0

3.5+7.1

5.0+5.0

5.0+6.0

5.0+7.1

6.0+6.0

6.0+7.1

7.1+7.1

Capacity Tables

Outdoor
air temp.
CDB
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0

SUPER MULTI NX E-Series Heat Pump

14C
TC
PI
kW
kW
8.06
2.49
7.83
2.58
7.31
2.81
7.09
2.91
6.71
3.10
6.49
3.22
6.21
2.90
8.59
2.93
8.35
3.03
7.79
3.30
7.56
3.42
7.16
3.59
6.92
3.44
6.68
2.90
8.28
2.60
8.05
2.69
7.51
2.93
7.28
3.04
6.90
3.23
6.67
3.35
6.37
2.90
8.81
2.66
8.57
2.76
8.00
3.00
7.75
3.11
7.34
3.31
7.10
3.44
6.73
2.90
8.84
2.67
8.60
2.77
8.02
3.01
7.78
3.12
7.37
3.32
7.12
3.44
6.75
2.90
9.04
2.79
8.79
2.89
8.21
3.14
7.95
3.26
7.54
3.47
7.28
3.44
6.91
2.90
9.05
2.79
8.80
2.89
8.21
3.14
7.96
3.26
7.54
3.47
7.29
3.44
6.92
2.90
9.07
2.79
8.82
2.89
8.23
3.14
7.98
3.26
7.56
3.47
7.31
3.44
6.93
2.90
9.09
2.79
8.84
2.89
8.25
3.15
8.00
3.27
7.58
3.48
7.33
3.44
6.95
2.90

16C
TC
PI
kW
kW
8.43
2.54
8.20
2.63
7.68
2.86
7.46
2.96
7.08
3.15
6.86
3.26
6.53
2.90
8.98
2.98
8.75
3.09
8.19
3.35
7.95
3.48
7.55
3.59
7.31
3.44
7.03
2.90
8.66
2.65
8.43
2.74
7.89
2.98
7.66
3.09
7.28
3.28
7.05
3.40
6.70
2.90
9.22
2.71
8.97
2.81
8.40
3.05
8.15
3.17
7.75
3.36
7.50
3.44
7.07
2.90
9.25
2.72
9.00
2.82
8.43
3.06
8.18
3.18
7.77
3.38
7.52
3.44
7.09
2.90
9.46
2.84
9.21
2.94
8.62
3.19
8.37
3.31
7.95
3.52
7.69
3.44
7.25
2.90
9.47
2.84
9.22
2.94
8.63
3.19
8.38
3.31
7.96
3.52
7.70
3.44
7.25
2.90
9.49
2.84
9.24
2.94
8.65
3.19
8.40
3.31
7.98
3.52
7.71
3.44
7.26
2.90
9.51
2.85
9.26
2.95
8.67
3.20
8.42
3.32
7.99
3.53
7.73
3.44
7.28
2.90

Indoor air temp.:CWB


18C
19C
TC
PI
TC
PI
kW
kW
kW
kW
8.80
2.59
8.98
2.61
8.57
2.68
8.76
2.70
8.05
2.90
8.23
2.93
7.83
3.01
8.01
3.03
7.45
3.20
7.64
3.22
7.23
3.31
7.41
3.34
6.84
2.90
7.00
2.90
9.38
3.04
9.57
3.07
9.14
3.14
9.34
3.17
8.58
3.41
8.78
3.44
8.34
3.54
8.54
3.56
7.95
3.59
8.14
3.59
7.71
3.44
7.90
3.44
7.34
2.90
7.49
2.90
9.04
2.70
9.23
2.72
8.81
2.79
9.00
2.82
8.27
3.03
8.46
3.05
8.04
3.14
8.23
3.16
7.66
3.33
7.85
3.36
7.43
3.44
7.61
3.44
7.01
2.90
7.17
2.90
9.62
2.77
9.82
2.79
9.37
2.86
9.58
2.89
8.80
3.10
9.00
3.13
8.56
3.22
8.76
3.24
8.15
3.42
8.35
3.44
7.89
3.44
8.08
3.44
7.39
2.90
7.55
2.90
9.65
2.77
9.85
2.80
9.41
2.87
9.61
2.90
8.83
3.11
9.04
3.14
8.59
3.23
8.79
3.25
8.18
3.43
8.38
3.45
7.91
3.44
8.11
3.44
7.41
2.90
7.57
2.90
9.87
2.89 10.08 2.92
9.62
2.99
9.83
3.02
9.03
3.25
9.24
3.28
8.78
3.37
8.99
3.39
8.36
3.57
8.57
3.59
8.08
3.44
8.27
3.44
7.57
2.90
7.73
2.90
9.88
2.89 10.09 2.92
9.63
2.99
9.84
3.02
9.04
3.25
9.25
3.28
8.79
3.37
9.00
3.39
8.37
3.57
8.58
3.59
8.09
3.44
8.28
3.44
7.58
2.90
7.74
2.90
9.90
2.89 10.11 2.92
9.65
2.99
9.86
3.02
9.06
3.25
9.27
3.28
8.81
3.37
9.02
3.39
8.39
3.57
8.60
3.59
8.10
3.44
8.30
3.44
7.59
2.90
7.75
2.90
9.93
2.90 10.13 2.93
9.67
3.00
9.88
3.03
9.08
3.26
9.29
3.29
8.83
3.38
9.04
3.40
8.41
3.59
8.61
3.59
8.12
3.44
8.31
3.44
7.61
2.90
7.77
2.90

22C
TC
PI
kW
kW
9.53
2.68
9.31
2.77
8.79
3.00
8.56
3.11
8.19
3.29
7.97
3.41
7.46
2.90
10.16 3.15
9.93
3.26
9.37
3.53
9.13
3.65
8.70
3.59
8.46
3.44
7.94
2.90
9.80
2.80
9.57
2.89
9.03
3.13
8.80
3.24
8.42
3.43
8.16
3.44
7.62
2.90
10.43 2.87
10.18 2.97
9.61
3.21
9.37
3.32
8.96
3.52
8.64
3.44
8.03
2.90
10.46 2.88
10.22 2.97
9.64
3.22
9.40
3.33
8.99
3.53
8.67
3.44
8.05
2.90
10.70 3.00
10.45 3.10
9.86
3.36
9.61
3.47
9.16
3.59
8.84
3.44
8.21
2.90
10.71 3.00
10.46 3.10
9.87
3.36
9.62
3.47
9.17
3.59
8.84
3.44
8.21
2.90
10.74 3.00
10.48 3.10
9.90
3.36
9.64
3.47
9.19
3.59
8.86
3.44
8.23
2.90
10.76 3.01
10.51 3.11
9.92
3.37
9.66
3.49
9.21
3.59
8.88
3.44
8.24
2.90

24C
TC
PI
kW
kW
9.90
2.73
9.68
2.82
9.16
3.05
8.93
3.15
8.56
3.34
8.33
3.44
7.75
2.90
10.56 3.21
10.32 3.32
9.76
3.58
9.52
3.71
9.07
3.59
8.81
3.44
8.23
2.90
10.17 2.85
9.94
2.94
9.41
3.18
9.18
3.29
8.79
3.48
8.51
3.44
7.92
2.90
10.83 2.92
10.58 3.02
10.01 3.26
9.77
3.37
9.36
3.57
9.01
3.44
8.33
2.90
10.87 2.93
10.62 3.03
10.05 3.27
9.80
3.38
9.39
3.58
9.04
3.44
8.36
2.90
11.11 3.06
10.86 3.16
10.28 3.41
10.03 3.53
9.55
3.59
9.20
3.44
8.51
2.90
11.13 3.06
10.87 3.16
10.29 3.41
10.04 3.53
9.56
3.59
9.21
3.44
8.52
2.90
11.15 3.06
10.90 3.16
10.31 3.41
10.06 3.53
9.58
3.59
9.23
3.44
8.53
2.90
11.18 3.07
10.92 3.17
10.33 3.42
10.08 3.54
9.59
3.59
9.25
3.44
8.55
2.90

95

Capacity Tables

Combination
(Capacity)
2.0+2.0+2.0

2.0+2.0+2.5

2.0+2.0+3.5

2.0+2.0+5.0

2.0+2.0+6.0

2.0+2.0+7.1

2.0+2.5+2.5

2.0+2.5+3.5

2.0+2.5+5.0

96

EDAU12-722

Outdoor
air temp.
CDB
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0

14C
TC
PI
kW
kW
6.67
1.72
6.48
1.78
6.05
1.94
5.87
2.01
5.56
2.14
5.37
2.22
5.19
2.30
6.99
1.90
6.80
1.97
6.34
2.14
6.15
2.22
5.83
2.36
5.63
2.45
5.44
2.55
7.65
2.24
7.44
2.32
6.95
2.52
6.73
2.61
6.38
2.78
6.17
2.89
5.93
2.90
8.45
2.44
8.21
2.53
7.67
2.75
7.43
2.85
7.04
3.04
6.81
3.15
6.47
2.90
8.87
2.67
8.63
2.77
8.05
3.01
7.80
3.12
7.39
3.32
7.15
3.44
6.77
2.90
9.08
2.79
8.83
2.89
8.24
3.15
7.99
3.27
7.57
3.48
7.32
3.44
6.94
2.90
7.34
2.09
7.14
2.16
6.66
2.35
6.46
2.44
6.12
2.60
5.92
2.70
5.71
2.80
7.95
2.44
7.73
2.53
7.21
2.75
6.99
2.85
6.62
3.04
6.40
3.15
6.12
2.90
8.67
2.56
8.43
2.65
7.87
2.88
7.63
2.99
7.23
3.18
6.98
3.30
6.62
2.90

16C
TC
PI
kW
kW
6.97
1.75
6.79
1.81
6.36
1.97
6.17
2.04
5.86
2.17
5.68
2.25
5.49
2.34
7.31
1.94
7.12
2.00
6.66
2.18
6.47
2.26
6.15
2.40
5.95
2.49
5.76
2.58
8.01
2.28
7.79
2.36
7.30
2.56
7.08
2.66
6.73
2.82
6.52
2.93
6.26
2.90
8.84
2.49
8.60
2.58
8.05
2.80
7.82
2.90
7.43
3.08
7.19
3.20
6.81
2.90
9.28
2.72
9.03
2.82
8.46
3.06
8.21
3.18
7.80
3.38
7.55
3.44
7.11
2.90
9.50
2.85
9.25
2.95
8.66
3.20
8.41
3.32
7.99
3.53
7.72
3.44
7.27
2.90
7.68
2.13
7.48
2.20
7.00
2.39
6.80
2.48
6.46
2.64
6.25
2.74
6.05
2.84
8.31
2.49
8.09
2.58
7.57
2.80
7.35
2.90
6.99
3.08
6.77
3.20
6.45
2.90
9.07
2.61
8.83
2.70
8.27
2.93
8.02
3.04
7.62
3.23
7.38
3.35
6.96
2.90

Indoor air temp.:CWB


18C
19C
TC
PI
TC
PI
kW
kW
kW
kW
7.28
1.78
7.43
1.80
7.09
1.85
7.25
1.86
6.66
2.00
6.82
2.02
6.48
2.08
6.63
2.09
6.17
2.20
6.32
2.22
5.98
2.29
6.14
2.30
5.80
2.37
5.95
2.39
7.63
1.97
7.79
1.99
7.44
2.04
7.60
2.06
6.98
2.21
7.14
2.23
6.79
2.29
6.95
2.31
6.47
2.44
6.63
2.45
6.27
2.53
6.43
2.54
6.08
2.62
6.24
2.64
8.36
2.32
8.53
2.34
8.14
2.40
8.32
2.42
7.65
2.61
7.82
2.63
7.43
2.70
7.61
2.72
7.08
2.87
7.26
2.89
6.87
2.97
7.04
3.00
6.58
2.90
6.74
2.90
9.22
2.54
9.42
2.56
8.99
2.62
9.18
2.65
8.44
2.85
8.63
2.87
8.21
2.95
8.40
2.97
7.82
3.13
8.01
3.16
7.58
3.25
7.77
3.27
7.14
2.90
7.30
2.90
9.68
2.77
9.89
2.80
9.44
2.87
9.64
2.90
8.86
3.11
9.07
3.14
8.62
3.23
8.82
3.25
8.21
3.43
8.41
3.45
7.94
3.44
8.13
3.44
7.43
2.90
7.60
2.90
9.92
2.90 10.12 2.93
9.66
3.00
9.87
3.03
9.07
3.26
9.28
3.29
8.82
3.38
9.03
3.40
8.40
3.59
8.60
3.59
8.11
3.44
8.30
3.44
7.60
2.90
7.76
2.90
8.02
2.17
8.18
2.19
7.81
2.24
7.98
2.26
7.34
2.43
7.50
2.45
7.13
2.52
7.30
2.54
6.79
2.68
6.96
2.70
6.59
2.78
6.76
2.80
6.38
2.88
6.55
2.90
8.67
2.54
8.86
2.56
8.45
2.62
8.64
2.65
7.94
2.85
8.12
2.87
7.72
2.95
7.90
2.97
7.35
3.13
7.53
3.16
7.13
3.25
7.31
3.27
6.76
2.90
6.92
2.90
9.47
2.66
9.66
2.68
9.22
2.75
9.42
2.77
8.66
2.98
8.86
3.01
8.42
3.09
8.62
3.11
8.02
3.28
8.22
3.30
7.78
3.40
7.98
3.43
7.29
2.90
7.45
2.90

22C
TC
PI
kW
kW
7.89
1.85
7.71
1.91
7.27
2.07
7.09
2.14
6.78
2.27
6.59
2.35
6.41
2.44
8.27
2.05
8.08
2.11
7.62
2.29
7.43
2.37
7.11
2.51
6.91
2.60
6.72
2.69
9.06
2.41
8.84
2.49
8.35
2.69
8.14
2.79
7.78
2.96
7.57
3.06
7.20
2.90
10.00 2.63
9.76
2.72
9.22
2.94
8.98
3.04
8.59
3.23
8.35
3.34
7.78
2.90
10.50 2.88
10.25 2.97
9.68
3.22
9.43
3.33
9.02
3.53
8.70
3.44
8.07
2.90
10.75 3.01
10.49 3.11
9.91
3.37
9.65
3.49
9.20
3.59
8.87
3.44
8.23
2.90
8.69
2.25
8.48
2.32
8.01
2.52
7.80
2.60
7.46
2.76
7.26
2.86
7.02
2.90
9.40
2.63
9.18
2.72
8.67
2.94
8.45
3.04
8.08
3.23
7.86
3.34
7.37
2.90
10.26 2.75
10.02 2.85
9.46
3.08
9.22
3.19
8.81
3.38
8.55
3.44
7.93
2.90

24C
TC
PI
kW
kW
8.20
1.88
8.01
1.95
7.58
2.10
7.39
2.18
7.08
2.30
6.90
2.39
6.71
2.47
8.59
2.08
8.40
2.15
7.94
2.32
7.75
2.40
7.43
2.55
7.23
2.64
7.04
2.73
9.41
2.45
9.20
2.53
8.70
2.74
8.49
2.83
8.13
3.00
7.92
3.10
7.50
2.90
10.38 2.68
10.15 2.77
9.60
2.99
9.37
3.09
8.98
3.27
8.74
3.39
8.09
2.90
10.90 2.93
10.66 3.03
10.08 3.27
9.84
3.38
9.43
3.58
9.07
3.44
8.38
2.90
11.16 3.07
10.91 3.17
10.32 3.42
10.07 3.54
9.58
3.59
9.24
3.44
8.54
2.90
9.02
2.29
8.82
2.37
8.34
2.56
8.14
2.64
7.80
2.80
7.60
2.90
7.32
2.90
9.77
2.68
9.55
2.77
9.03
2.99
8.81
3.09
8.44
3.27
8.22
3.39
7.67
2.90
10.66 2.80
10.42 2.90
9.85
3.13
9.61
3.24
9.21
3.43
8.92
3.44
8.24
2.90

SUPER MULTI NX E-Series Heat Pump

EDAU12-722

Combination
(Capacity)
2.0+2.5+6.0

2.0+2.5+7.1

2.0+3.5+3.5

2.0+3.5+5.0

2.0+3.5+6.0

2.0+3.5+7.1

2.0+5.0+5.0

2.0+5.0+6.0

2.0+5.0+7.1

Capacity Tables

Outdoor
air temp.
CDB
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0

SUPER MULTI NX E-Series Heat Pump

14C
TC
PI
kW
kW
8.89
2.67
8.65
2.77
8.07
3.01
7.82
3.12
7.41
3.32
7.16
3.44
6.78
2.90
9.08
2.79
8.83
2.89
8.24
3.15
7.99
3.27
7.57
3.48
7.32
3.44
6.94
2.90
8.28
2.60
8.05
2.69
7.51
2.93
7.28
3.04
6.90
3.23
6.67
3.35
6.37
2.90
8.86
2.67
8.62
2.77
8.04
3.01
7.80
3.12
7.39
3.32
7.14
3.44
6.77
2.90
9.07
2.79
8.82
2.89
8.23
3.14
7.98
3.26
7.56
3.47
7.31
3.44
6.93
2.90
9.12
2.79
8.87
2.89
8.28
3.15
8.03
3.27
7.60
3.48
7.35
3.44
6.96
2.90
9.45
2.74
9.18
2.83
8.57
3.08
8.31
3.20
7.87
3.40
7.60
3.44
7.14
2.90
9.60
2.86
9.33
2.96
8.71
3.22
8.44
3.34
8.00
3.56
7.72
3.44
7.27
2.90
9.66
2.87
9.39
2.97
8.76
3.23
8.49
3.35
8.05
3.57
7.77
3.44
7.31
2.90

16C
TC
PI
kW
kW
9.30
2.72
9.05
2.82
8.48
3.06
8.23
3.18
7.82
3.38
7.56
3.44
7.12
2.90
9.50
2.85
9.25
2.95
8.66
3.20
8.41
3.32
7.99
3.53
7.72
3.44
7.27
2.90
8.66
2.65
8.43
2.74
7.89
2.98
7.66
3.09
7.28
3.28
7.05
3.40
6.70
2.90
9.27
2.72
9.02
2.82
8.45
3.06
8.20
3.18
7.79
3.38
7.54
3.44
7.10
2.90
9.49
2.84
9.24
2.94
8.65
3.19
8.40
3.31
7.98
3.52
7.71
3.44
7.26
2.90
9.54
2.85
9.29
2.95
8.70
3.20
8.44
3.32
8.02
3.53
7.75
3.44
7.30
2.90
9.88
2.79
9.62
2.89
9.00
3.14
8.74
3.25
8.30
3.46
8.01
3.44
7.49
2.90
10.04 2.92
9.77
3.02
9.15
3.28
8.88
3.40
8.43
3.59
8.13
3.44
7.61
2.90
10.10 2.92
9.83
3.03
9.20
3.29
8.94
3.41
8.48
3.59
8.18
3.44
7.65
2.90

Indoor air temp.:CWB


18C
19C
TC
PI
TC
PI
kW
kW
kW
kW
9.71
2.77
9.91
2.80
9.46
2.87
9.66
2.90
8.88
3.11
9.09
3.14
8.64
3.23
8.84
3.25
8.22
3.43
8.43
3.45
7.96
3.44
8.15
3.44
7.45
2.90
7.61
2.90
9.92
2.90 10.12 2.93
9.66
3.00
9.87
3.03
9.07
3.26
9.28
3.29
8.82
3.38
9.03
3.40
8.40
3.59
8.60
3.59
8.11
3.44
8.30
3.44
7.60
2.90
7.76
2.90
9.04
2.70
9.23
2.72
8.81
2.79
9.00
2.82
8.27
3.03
8.46
3.05
8.04
3.14
8.23
3.16
7.66
3.33
7.85
3.36
7.43
3.44
7.61
3.44
7.01
2.90
7.17
2.90
9.67
2.77
9.88
2.80
9.43
2.87
9.63
2.90
8.85
3.11
9.06
3.14
8.61
3.23
8.81
3.25
8.20
3.43
8.40
3.45
7.93
3.44
8.12
3.44
7.43
2.90
7.59
2.90
9.90
2.89 10.11 2.92
9.65
2.99
9.86
3.02
9.06
3.25
9.27
3.28
8.81
3.37
9.02
3.39
8.39
3.57
8.60
3.59
8.10
3.44
8.30
3.44
7.59
2.90
7.75
2.90
9.96
2.90 10.17 2.93
9.71
3.00
9.91
3.03
9.11
3.26
9.32
3.29
8.86
3.38
9.07
3.40
8.44
3.59
8.64
3.59
8.15
3.44
8.34
3.44
7.63
2.90
7.79
2.90
10.31 2.84 10.53 2.87
10.05 2.94 10.26 2.97
9.44
3.19
9.65
3.22
9.17
3.31
9.39
3.33
8.74
3.51
8.95
3.54
8.42
3.44
8.62
3.44
7.83
2.90
8.00
2.90
10.48 2.97 10.69 3.00
10.21 3.07 10.43 3.10
9.59
3.33
9.81
3.36
9.32
3.46
9.54
3.48
8.86
3.59
9.06
3.59
8.54
3.44
8.73
3.44
7.95
2.90
8.11
2.90
10.54 2.98 10.76 3.01
10.27 3.08 10.49 3.11
9.65
3.34
9.87
3.37
9.38
3.47
9.60
3.49
8.91
3.59
9.12
3.59
8.58
3.44
8.78
3.44
7.99
2.90
8.16
2.90

22C
TC
PI
kW
kW
10.52 2.88
10.27 2.97
9.70
3.22
9.45
3.33
9.04
3.53
8.72
3.44
8.09
2.90
10.75 3.01
10.49 3.11
9.91
3.37
9.65
3.49
9.20
3.59
8.87
3.44
8.23
2.90
9.80
2.80
9.57
2.89
9.03
3.13
8.80
3.24
8.42
3.43
8.16
3.44
7.62
2.90
10.49 2.88
10.24 2.97
9.66
3.22
9.42
3.33
9.01
3.53
8.69
3.44
8.06
2.90
10.74 3.00
10.48 3.10
9.90
3.36
9.64
3.47
9.19
3.59
8.86
3.44
8.23
2.90
10.79 3.01
10.54 3.11
9.95
3.37
9.70
3.49
9.24
3.59
8.91
3.44
8.26
2.90
11.18 2.95
10.91 3.05
10.30 3.30
10.04 3.41
9.59
3.59
9.21
3.44
8.49
2.90
11.35 3.08
11.09 3.19
10.47 3.45
10.20 3.57
9.67
3.59
9.32
3.44
8.60
2.90
11.43 3.09
11.16 3.19
10.53 3.46
10.26 3.58
9.73
3.59
9.37
3.44
8.65
2.90

24C
TC
PI
kW
kW
10.93 2.93
10.68 3.03
10.11 3.27
9.86
3.38
9.45
3.58
9.09
3.44
8.39
2.90
11.16 3.07
10.91 3.17
10.32 3.42
10.07 3.54
9.58
3.59
9.24
3.44
8.54
2.90
10.17 2.85
9.94
2.94
9.41
3.18
9.18
3.29
8.79
3.48
8.51
3.44
7.92
2.90
10.89 2.93
10.65 3.03
10.07 3.27
9.82
3.38
9.41
3.58
9.06
3.44
8.37
2.90
11.15 3.06
10.90 3.16
10.31 3.41
10.06 3.53
9.58
3.59
9.23
3.44
8.53
2.90
11.21 3.07
10.96 3.17
10.37 3.42
10.11 3.54
9.62
3.59
9.27
3.44
8.57
2.90
11.61 3.00
11.35 3.10
10.73 3.35
10.47 3.47
9.99
3.59
9.59
3.44
8.81
2.90
11.79 3.14
11.53 3.24
10.91 3.50
10.64 3.62
10.07 3.59
9.69
3.44
8.92
2.90
11.87 3.15
11.60 3.25
10.97 3.51
10.71 3.63
10.13 3.59
9.75
3.44
8.96
2.90

97

Capacity Tables

Combination
(Capacity)
2.0+6.0+6.0

2.5+2.5+2.5

2.5+2.5+3.5

2.5+2.5+5.0

2.5+2.5+6.0

2.5+2.5+7.1

2.5+3.5+3.5

2.5+3.5+5.0

2.5+3.5+6.0

98

EDAU12-722

Outdoor
air temp.
CDB
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0

14C
TC
PI
kW
kW
9.66
2.87
9.39
2.97
8.76
3.23
8.49
3.35
8.05
3.57
7.77
3.44
7.31
2.90
7.65
2.24
7.44
2.32
6.95
2.52
6.73
2.61
6.38
2.78
6.17
2.89
5.93
2.90
8.10
2.49
7.87
2.58
7.35
2.81
7.12
2.91
6.75
3.10
6.52
3.22
6.23
2.90
8.85
2.66
8.61
2.76
8.03
3.00
7.79
3.11
7.38
3.31
7.13
3.44
6.76
2.90
8.89
2.67
8.65
2.77
8.07
3.01
7.82
3.12
7.41
3.32
7.16
3.44
6.78
2.90
9.08
2.79
8.83
2.89
8.24
3.15
7.99
3.27
7.57
3.48
7.32
3.44
6.94
2.90
8.39
2.54
8.16
2.63
7.61
2.86
7.38
2.97
6.99
3.16
6.76
3.28
6.43
2.90
8.86
2.67
8.62
2.77
8.04
3.01
7.80
3.12
7.39
3.32
7.14
3.44
6.77
2.90
9.07
2.79
8.82
2.89
8.23
3.14
7.98
3.26
7.56
3.47
7.31
3.44
6.93
2.90

16C
TC
PI
kW
kW
10.10 2.92
9.83
3.03
9.20
3.29
8.94
3.41
8.48
3.59
8.18
3.44
7.65
2.90
8.01
2.28
7.79
2.36
7.30
2.56
7.08
2.66
6.73
2.82
6.52
2.93
6.26
2.90
8.47
2.54
8.24
2.63
7.72
2.86
7.49
2.96
7.12
3.15
6.89
3.26
6.56
2.90
9.26
2.71
9.01
2.81
8.44
3.05
8.19
3.17
7.78
3.36
7.53
3.44
7.09
2.90
9.30
2.72
9.05
2.82
8.48
3.06
8.23
3.18
7.82
3.38
7.56
3.44
7.12
2.90
9.50
2.85
9.25
2.95
8.66
3.20
8.41
3.32
7.99
3.53
7.72
3.44
7.27
2.90
8.77
2.59
8.54
2.68
8.00
2.91
7.76
3.02
7.38
3.21
7.14
3.33
6.76
2.90
9.27
2.72
9.02
2.82
8.45
3.06
8.20
3.18
7.79
3.38
7.54
3.44
7.10
2.90
9.49
2.84
9.24
2.94
8.65
3.19
8.40
3.31
7.98
3.52
7.71
3.44
7.26
2.90

Indoor air temp.:CWB


18C
19C
TC
PI
TC
PI
kW
kW
kW
kW
10.54 2.98 10.76 3.01
10.27 3.08 10.49 3.11
9.65
3.34
9.87
3.37
9.38
3.47
9.60
3.49
8.91
3.59
9.12
3.59
8.58
3.44
8.78
3.44
7.99
2.90
8.16
2.90
8.36
2.32
8.53
2.34
8.14
2.40
8.32
2.42
7.65
2.61
7.82
2.63
7.43
2.70
7.61
2.72
7.08
2.87
7.26
2.89
6.87
2.97
7.04
3.00
6.58
2.90
6.74
2.90
8.84
2.59
9.02
2.61
8.61
2.68
8.80
2.70
8.09
2.90
8.27
2.93
7.86
3.01
8.05
3.03
7.49
3.20
7.68
3.22
7.26
3.31
7.45
3.34
6.87
2.90
7.03
2.90
9.66
2.77
9.87
2.79
9.42
2.86
9.62
2.89
8.84
3.10
9.05
3.13
8.60
3.22
8.80
3.24
8.19
3.42
8.39
3.44
7.92
3.44
8.12
3.44
7.42
2.90
7.58
2.90
9.71
2.77
9.91
2.80
9.46
2.87
9.66
2.90
8.88
3.11
9.09
3.14
8.64
3.23
8.84
3.25
8.22
3.43
8.43
3.45
7.96
3.44
8.15
3.44
7.45
2.90
7.61
2.90
9.92
2.90 10.12 2.93
9.66
3.00
9.87
3.03
9.07
3.26
9.28
3.29
8.82
3.38
9.03
3.40
8.40
3.59
8.60
3.59
8.11
3.44
8.30
3.44
7.60
2.90
7.76
2.90
9.16
2.64
9.35
2.66
8.92
2.73
9.12
2.75
8.38
2.96
8.57
2.99
8.15
3.07
8.34
3.09
7.76
3.26
7.95
3.28
7.53
3.38
7.72
3.40
7.09
2.90
7.24
2.90
9.67
2.77
9.88
2.80
9.43
2.87
9.63
2.90
8.85
3.11
9.06
3.14
8.61
3.23
8.81
3.25
8.20
3.43
8.40
3.45
7.93
3.44
8.12
3.44
7.43
2.90
7.59
2.90
9.90
2.89 10.11 2.92
9.65
2.99
9.86
3.02
9.06
3.25
9.27
3.28
8.81
3.37
9.02
3.39
8.39
3.57
8.60
3.59
8.10
3.44
8.30
3.44
7.59
2.90
7.75
2.90

22C
TC
PI
kW
kW
11.43 3.09
11.16 3.19
10.53 3.46
10.26 3.58
9.73
3.59
9.37
3.44
8.65
2.90
9.06
2.41
8.84
2.49
8.35
2.69
8.14
2.79
7.78
2.96
7.57
3.06
7.20
2.90
9.58
2.68
9.36
2.77
8.83
3.00
8.61
3.11
8.23
3.29
8.01
3.41
7.49
2.90
10.47 2.87
10.23 2.97
9.65
3.21
9.41
3.32
9.00
3.52
8.68
3.44
8.06
2.90
10.52 2.88
10.27 2.97
9.70
3.22
9.45
3.33
9.04
3.53
8.72
3.44
8.09
2.90
10.75 3.01
10.49 3.11
9.91
3.37
9.65
3.49
9.20
3.59
8.87
3.44
8.23
2.90
9.93
2.74
9.69
2.83
9.15
3.06
8.92
3.17
8.53
3.36
8.28
3.44
7.71
2.90
10.49 2.88
10.24 2.97
9.66
3.22
9.42
3.33
9.01
3.53
8.69
3.44
8.06
2.90
10.74 3.00
10.48 3.10
9.90
3.36
9.64
3.47
9.19
3.59
8.86
3.44
8.23
2.90

24C
TC
PI
kW
kW
11.87 3.15
11.60 3.25
10.97 3.51
10.71 3.63
10.13 3.59
9.75
3.44
8.96
2.90
9.41
2.45
9.20
2.53
8.70
2.74
8.49
2.83
8.13
3.00
7.92
3.10
7.50
2.90
9.95
2.73
9.73
2.82
9.20
3.05
8.98
3.15
8.60
3.34
8.37
3.44
7.79
2.90
10.88 2.92
10.63 3.02
10.06 3.26
9.81
3.37
9.40
3.57
9.05
3.44
8.36
2.90
10.93 2.93
10.68 3.03
10.11 3.27
9.86
3.38
9.45
3.58
9.09
3.44
8.39
2.90
11.16 3.07
10.91 3.17
10.32 3.42
10.07 3.54
9.58
3.59
9.24
3.44
8.54
2.90
10.31 2.79
10.08 2.88
9.53
3.11
9.30
3.22
8.91
3.41
8.64
3.44
8.01
2.90
10.89 2.93
10.65 3.03
10.07 3.27
9.82
3.38
9.41
3.58
9.06
3.44
8.37
2.90
11.15 3.06
10.90 3.16
10.31 3.41
10.06 3.53
9.58
3.59
9.23
3.44
8.53
2.90

SUPER MULTI NX E-Series Heat Pump

EDAU12-722

Combination
(Capacity)
2.5+3.5+7.1

2.5+5.0+5.0

2.5+5.0+6.0

2.5+6.0+6.0

3.5+3.5+3.5

3.5+3.5+5.0

3.5+3.5+6.0

3.5+3.5+7.1

3.5+5.0+5.0

Capacity Tables

Outdoor
air temp.
CDB
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0

SUPER MULTI NX E-Series Heat Pump

14C
TC
PI
kW
kW
9.12
2.79
8.87
2.89
8.28
3.15
8.03
3.27
7.60
3.48
7.35
3.44
6.96
2.90
9.53
2.79
9.26
2.89
8.64
3.15
8.38
3.27
7.94
3.48
7.66
3.44
7.21
2.90
9.64
2.86
9.37
2.96
8.74
3.22
8.48
3.34
8.03
3.56
7.75
3.44
7.29
2.90
9.66
2.87
9.39
2.97
8.76
3.23
8.49
3.35
8.05
3.57
7.77
3.44
7.31
2.90
8.63
2.60
8.39
2.69
7.83
2.93
7.59
3.04
7.19
3.23
6.95
3.35
6.60
2.90
9.04
2.79
8.79
2.89
8.21
3.14
7.95
3.26
7.54
3.47
7.28
3.44
6.91
2.90
9.12
2.79
8.87
2.89
8.28
3.14
8.03
3.26
7.60
3.47
7.35
3.44
6.96
2.90
9.10
2.79
8.85
2.89
8.26
3.15
8.01
3.27
7.59
3.48
7.33
3.44
6.95
2.90
9.64
2.86
9.37
2.96
8.74
3.22
8.48
3.34
8.03
3.56
7.75
3.44
7.29
2.90

16C
TC
PI
kW
kW
9.54
2.85
9.29
2.95
8.70
3.20
8.44
3.32
8.02
3.53
7.75
3.44
7.30
2.90
9.96
2.85
9.70
2.95
9.08
3.20
8.82
3.32
8.37
3.53
8.08
3.44
7.55
2.90
10.08 2.92
9.81
3.02
9.19
3.28
8.92
3.40
8.47
3.59
8.16
3.44
7.64
2.90
10.10 2.92
9.83
3.03
9.20
3.29
8.94
3.41
8.48
3.59
8.18
3.44
7.65
2.90
9.03
2.65
8.79
2.74
8.23
2.98
7.99
3.09
7.59
3.28
7.35
3.40
6.93
2.90
9.46
2.84
9.21
2.94
8.62
3.19
8.37
3.31
7.95
3.52
7.69
3.44
7.25
2.90
9.54
2.84
9.29
2.94
8.70
3.19
8.44
3.31
8.02
3.52
7.75
3.44
7.30
2.90
9.52
2.85
9.27
2.95
8.68
3.20
8.42
3.32
8.00
3.53
7.74
3.44
7.29
2.90
10.08 2.92
9.81
3.02
9.19
3.28
8.92
3.40
8.47
3.59
8.16
3.44
7.64
2.90

Indoor air temp.:CWB


18C
19C
TC
PI
TC
PI
kW
kW
kW
kW
9.96
2.90 10.17 2.93
9.71
3.00
9.91
3.03
9.11
3.26
9.32
3.29
8.86
3.38
9.07
3.40
8.44
3.59
8.64
3.59
8.15
3.44
8.34
3.44
7.63
2.90
7.79
2.90
10.40 2.90 10.62 2.93
10.13 3.00 10.35 3.03
9.52
3.26
9.73
3.29
9.25
3.38
9.47
3.40
8.81
3.59
9.02
3.59
8.48
3.44
8.68
3.44
7.89
2.90
8.06
2.90
10.52 2.97 10.74 3.00
10.25 3.07 10.47 3.10
9.63
3.33
9.85
3.36
9.36
3.46
9.58
3.48
8.89
3.59
9.10
3.59
8.57
3.44
8.77
3.44
7.97
2.90
8.14
2.90
10.54 2.98 10.76 3.01
10.27 3.08 10.49 3.11
9.65
3.34
9.87
3.37
9.38
3.47
9.60
3.49
8.91
3.59
9.12
3.59
8.58
3.44
8.78
3.44
7.99
2.90
8.16
2.90
9.42
2.70
9.62
2.72
9.18
2.79
9.38
2.82
8.62
3.03
8.82
3.05
8.38
3.14
8.58
3.16
7.98
3.33
8.18
3.36
7.74
3.44
7.93
3.44
7.26
2.90
7.42
2.90
9.87
2.89 10.08 2.92
9.62
2.99
9.83
3.02
9.03
3.25
9.24
3.28
8.78
3.37
8.99
3.39
8.36
3.57
8.57
3.59
8.08
3.44
8.27
3.44
7.57
2.90
7.73
2.90
9.96
2.89 10.17 2.92
9.71
2.99
9.91
3.02
9.11
3.25
9.32
3.28
8.86
3.37
9.07
3.39
8.44
3.57
8.65
3.59
8.15
3.44
8.34
3.44
7.62
2.90
7.79
2.90
9.94
2.90 10.15 2.93
9.68
3.00
9.89
3.03
9.09
3.26
9.30
3.29
8.84
3.38
9.05
3.40
8.42
3.59
8.62
3.59
8.13
3.44
8.32
3.44
7.61
2.90
7.77
2.90
10.52 2.97 10.74 3.00
10.25 3.07 10.47 3.10
9.63
3.33
9.85
3.36
9.36
3.46
9.58
3.48
8.89
3.59
9.10
3.59
8.57
3.44
8.77
3.44
7.97
2.90
8.14
2.90

22C
TC
PI
kW
kW
10.79 3.01
10.54 3.11
9.95
3.37
9.70
3.49
9.24
3.59
8.91
3.44
8.26
2.90
11.27 3.01
11.01 3.11
10.39 3.37
10.12 3.49
9.64
3.59
9.26
3.44
8.55
2.90
11.40 3.08
11.13 3.19
10.51 3.45
10.24 3.57
9.71
3.59
9.35
3.44
8.63
2.90
11.43 3.09
11.16 3.19
10.53 3.46
10.26 3.58
9.73
3.59
9.37
3.44
8.65
2.90
10.21 2.80
9.97
2.89
9.41
3.13
9.17
3.24
8.77
3.43
8.49
3.44
7.89
2.90
10.70 3.00
10.45 3.10
9.86
3.36
9.61
3.47
9.16
3.59
8.84
3.44
8.21
2.90
10.79 3.00
10.54 3.10
9.95
3.36
9.70
3.47
9.24
3.59
8.91
3.44
8.26
2.90
10.77 3.01
10.52 3.11
9.93
3.37
9.68
3.49
9.22
3.59
8.89
3.44
8.25
2.90
11.40 3.08
11.13 3.19
10.51 3.45
10.24 3.57
9.71
3.59
9.35
3.44
8.63
2.90

24C
TC
PI
kW
kW
11.21 3.07
10.96 3.17
10.37 3.42
10.11 3.54
9.62
3.59
9.27
3.44
8.57
2.90
11.71 3.07
11.44 3.17
10.83 3.42
10.56 3.54
10.03 3.59
9.64
3.44
8.86
2.90
11.84 3.14
11.58 3.24
10.95 3.50
10.68 3.62
10.11 3.59
9.73
3.44
8.95
2.90
11.87 3.15
11.60 3.25
10.97 3.51
10.71 3.63
10.13 3.59
9.75
3.44
8.96
2.90
10.61 2.85
10.37 2.94
9.81
3.18
9.57
3.29
9.17
3.48
8.86
3.44
8.20
2.90
11.11 3.06
10.86 3.16
10.28 3.41
10.03 3.53
9.55
3.59
9.20
3.44
8.51
2.90
11.21 3.06
10.96 3.16
10.37 3.41
10.11 3.53
9.63
3.59
9.28
3.44
8.57
2.90
11.19 3.07
10.94 3.17
10.35 3.42
10.09 3.54
9.60
3.59
9.26
3.44
8.56
2.90
11.84 3.14
11.58 3.24
10.95 3.50
10.68 3.62
10.11 3.59
9.73
3.44
8.95
2.90

99

Capacity Tables

Combination
(Capacity)
3.5+5.0+6.0

2.0+2.0+2.0+2.0

2.0+2.0+2.0+2.5

2.0+2.0+2.0+3.5

2.0+2.0+2.0+5.0

2.0+2.0+2.0+6.0

2.0+2.0+2.0+7.1

2.0+2.0+2.5+2.5

2.0+2.0+2.5+3.5

100

EDAU12-722

Outdoor
air temp.
CDB
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0

14C
TC
PI
kW
kW
9.66
2.87
9.39
2.97
8.76
3.23
8.49
3.35
8.05
3.57
7.77
3.44
7.31
2.90
7.95
2.02
7.73
2.09
7.21
2.28
6.99
2.36
6.62
2.52
6.40
2.61
6.18
2.71
8.21
2.13
7.98
2.20
7.45
2.40
7.22
2.49
6.84
2.65
6.61
2.75
6.38
2.85
8.67
2.39
8.43
2.48
7.87
2.70
7.63
2.80
7.23
2.98
6.98
3.09
6.63
2.90
9.20
2.56
8.95
2.66
8.35
2.89
8.10
3.00
7.67
3.19
7.41
3.31
6.97
2.90
9.45
2.74
9.18
2.84
8.57
3.09
8.31
3.21
7.87
3.42
7.60
3.44
7.14
2.90
9.61
2.81
9.34
2.91
8.72
3.17
8.45
3.29
8.01
3.50
7.72
3.44
7.26
2.90
8.45
2.28
8.21
2.37
7.67
2.58
7.43
2.67
7.04
2.84
6.81
2.95
6.51
2.90
8.87
2.67
8.63
2.77
8.05
3.01
7.80
3.12
7.39
3.32
7.15
3.44
6.77
2.90

16C
TC
PI
kW
kW
10.10 2.92
9.83
3.03
9.20
3.29
8.94
3.41
8.48
3.59
8.18
3.44
7.65
2.90
8.31
2.06
8.09
2.13
7.57
2.32
7.35
2.40
6.99
2.55
6.77
2.65
6.54
2.75
8.58
2.17
8.36
2.25
7.82
2.44
7.60
2.53
7.22
2.69
6.99
2.79
6.76
2.90
9.07
2.44
8.83
2.52
8.27
2.74
8.02
2.84
7.62
3.02
7.38
3.14
6.98
2.90
9.63
2.61
9.37
2.71
8.77
2.94
8.52
3.05
8.09
3.24
7.84
3.36
7.32
2.90
9.88
2.80
9.62
2.90
9.00
3.15
8.74
3.26
8.30
3.47
8.01
3.44
7.49
2.90
10.05 2.87
9.78
2.97
9.16
3.22
8.89
3.34
8.45
3.55
8.14
3.44
7.61
2.90
8.84
2.33
8.60
2.41
8.05
2.62
7.82
2.72
7.43
2.89
7.19
3.00
6.85
2.90
9.28
2.72
9.03
2.82
8.46
3.06
8.21
3.18
7.80
3.38
7.55
3.44
7.11
2.90

Indoor air temp.:CWB


18C
19C
TC
PI
TC
PI
kW
kW
kW
kW
10.54 2.98 10.76 3.01
10.27 3.08 10.49 3.11
9.65
3.34
9.87
3.37
9.38
3.47
9.60
3.49
8.91
3.59
9.12
3.59
8.58
3.44
8.78
3.44
7.99
2.90
8.16
2.90
8.67
2.10
8.86
2.12
8.45
2.17
8.64
2.19
7.94
2.36
8.12
2.38
7.72
2.44
7.90
2.46
7.35
2.59
7.53
2.61
7.13
2.69
7.31
2.71
6.91
2.79
7.09
2.81
8.96
2.21
9.15
2.23
8.73
2.29
8.92
2.31
8.20
2.48
8.39
2.50
7.97
2.57
8.16
2.59
7.59
2.73
7.78
2.75
7.36
2.83
7.55
2.85
7.11
2.90
7.28
2.90
9.47
2.48
9.66
2.51
9.22
2.57
9.42
2.59
8.66
2.79
8.86
2.81
8.42
2.89
8.62
2.91
8.02
3.07
8.22
3.09
7.78
3.18
7.98
3.21
7.32
2.90
7.49
2.90
10.05 2.66 10.26 2.69
9.79
2.76 10.00 2.78
9.19
2.99
9.41
3.01
8.94
3.10
9.15
3.12
8.51
3.29
8.72
3.31
8.26
3.41
8.47
3.44
7.67
2.90
7.84
2.90
10.31 2.85 10.53 2.88
10.05 2.95 10.26 2.98
9.44
3.20
9.65
3.23
9.17
3.32
9.39
3.34
8.74
3.52
8.95
3.55
8.42
3.44
8.62
3.44
7.83
2.90
8.00
2.90
10.49 2.92 10.71 2.95
10.22 3.02 10.44 3.05
9.60
3.28
9.82
3.30
9.33
3.40
9.55
3.42
8.88
3.59
9.09
3.59
8.55
3.44
8.74
3.44
7.94
2.90
8.11
2.90
9.22
2.37
9.42
2.40
8.99
2.46
9.18
2.48
8.44
2.66
8.63
2.69
8.21
2.76
8.40
2.78
7.82
2.93
8.01
2.95
7.58
3.04
7.77
3.06
7.20
2.90
7.36
2.90
9.68
2.77
9.89
2.80
9.44
2.87
9.64
2.90
8.86
3.11
9.07
3.14
8.62
3.23
8.82
3.25
8.21
3.43
8.41
3.45
7.94
3.44
8.13
3.44
7.43
2.90
7.60
2.90

22C
TC
PI
kW
kW
11.43 3.09
11.16 3.19
10.53 3.46
10.26 3.58
9.73
3.59
9.37
3.44
8.65
2.90
9.40
2.18
9.18
2.25
8.67
2.44
8.45
2.52
8.08
2.67
7.86
2.77
7.64
2.87
9.71
2.29
9.48
2.37
8.95
2.56
8.72
2.65
8.34
2.81
8.12
2.91
7.78
2.90
10.26 2.58
10.02 2.66
9.46
2.88
9.22
2.98
8.81
3.16
8.57
3.27
7.98
2.90
10.89 2.76
10.63 2.86
10.04 3.09
9.78
3.20
9.36
3.39
9.06
3.44
8.33
2.90
11.18 2.96
10.91 3.06
10.30 3.31
10.04 3.42
9.58
3.59
9.20
3.44
8.49
2.90
11.37 3.03
11.10 3.13
10.48 3.39
10.21 3.51
9.71
3.59
9.33
3.44
8.60
2.90
10.00 2.46
9.76
2.54
9.22
2.75
8.98
2.85
8.59
3.02
8.35
3.13
7.86
2.90
10.50 2.88
10.25 2.97
9.68
3.22
9.43
3.33
9.02
3.53
8.70
3.44
8.07
2.90

24C
TC
PI
kW
kW
11.87 3.15
11.60 3.25
10.97 3.51
10.71 3.63
10.13 3.59
9.75
3.44
8.96
2.90
9.77
2.22
9.55
2.29
9.03
2.48
8.81
2.56
8.44
2.71
8.22
2.81
7.99
2.90
10.09 2.34
9.86
2.41
9.33
2.61
9.10
2.70
8.72
2.86
8.49
2.96
8.11
2.90
10.66 2.62
10.42 2.71
9.85
2.93
9.61
3.03
9.21
3.21
8.97
3.32
8.30
2.90
11.31 2.81
11.06 2.91
10.46 3.14
10.20 3.25
9.78
3.44
9.45
3.44
8.66
2.90
11.61 3.01
11.35 3.11
10.73 3.36
10.47 3.48
9.98
3.59
9.58
3.44
8.81
2.90
11.81 3.08
11.54 3.19
10.92 3.44
10.65 3.56
10.11 3.59
9.71
3.44
8.92
2.90
10.38 2.51
10.15 2.59
9.60
2.80
9.37
2.89
8.98
3.06
8.74
3.17
8.18
2.90
10.90 2.93
10.66 3.03
10.08 3.27
9.84
3.38
9.43
3.58
9.07
3.44
8.38
2.90

SUPER MULTI NX E-Series Heat Pump

EDAU12-722

Combination
(Capacity)
2.0+2.0+2.5+5.0

2.0+2.0+2.5+6.0

2.0+2.0+2.5+7.1

2.0+2.0+3.5+3.5

2.0+2.0+3.5+5.0

2.0+2.0+3.5+6.0

2.0+2.0+5.0+5.0

2.0+2.5+2.5+2.5

2.0+2.5+2.5+3.5

Capacity Tables

Outdoor
air temp.
CDB
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0

SUPER MULTI NX E-Series Heat Pump

14C
TC
PI
kW
kW
9.33
2.68
9.08
2.78
8.47
3.02
8.21
3.13
7.78
3.33
7.52
3.44
7.06
2.90
9.53
2.74
9.26
2.84
8.64
3.09
8.38
3.21
7.94
3.42
7.66
3.44
7.19
2.90
9.65
2.88
9.38
2.98
8.75
3.24
8.49
3.36
8.04
3.58
7.76
3.44
7.30
2.90
8.91
2.67
8.66
2.77
8.09
3.01
7.84
3.12
7.43
3.32
7.18
3.44
6.80
2.90
9.53
2.80
9.26
2.90
8.64
3.16
8.38
3.28
7.94
3.49
7.66
3.44
7.21
2.90
9.64
2.87
9.37
2.97
8.74
3.23
8.48
3.35
8.03
3.57
7.75
3.44
7.30
2.90
9.66
2.56
9.39
2.65
8.76
2.88
8.49
2.99
8.05
3.18
7.78
3.30
7.27
2.90
8.67
2.39
8.43
2.48
7.87
2.70
7.63
2.80
7.23
2.98
6.98
3.09
6.63
2.90
8.91
2.67
8.66
2.77
8.09
3.01
7.84
3.12
7.43
3.32
7.18
3.44
6.80
2.90

16C
TC
PI
kW
kW
9.76
2.73
9.50
2.83
8.90
3.07
8.64
3.19
8.21
3.39
7.93
3.44
7.41
2.90
9.96
2.80
9.70
2.90
9.08
3.15
8.82
3.26
8.37
3.47
8.08
3.44
7.54
2.90
10.09 2.93
9.82
3.04
9.20
3.30
8.93
3.42
8.47
3.59
8.17
3.44
7.65
2.90
9.32
2.72
9.07
2.82
8.50
3.06
8.25
3.18
7.84
3.38
7.58
3.44
7.13
2.90
9.96
2.86
9.70
2.96
9.08
3.21
8.82
3.33
8.37
3.54
8.08
3.44
7.55
2.90
10.08 2.92
9.81
3.03
9.19
3.29
8.92
3.41
8.47
3.59
8.17
3.44
7.64
2.90
10.10 2.61
9.83
2.70
9.20
2.93
8.94
3.04
8.49
3.23
8.22
3.35
7.64
2.90
9.07
2.44
8.83
2.52
8.27
2.74
8.02
2.84
7.62
3.02
7.38
3.14
6.98
2.90
9.32
2.72
9.07
2.82
8.50
3.06
8.25
3.18
7.84
3.38
7.58
3.44
7.13
2.90

Indoor air temp.:CWB


18C
19C
TC
PI
TC
PI
kW
kW
kW
kW
10.19 2.78 10.40 2.81
9.93
2.88 10.14 2.91
9.33
3.12
9.54
3.15
9.07
3.24
9.28
3.26
8.63
3.44
8.85
3.46
8.34
3.44
8.54
3.44
7.75
2.90
7.92
2.90
10.40 2.85 10.62 2.88
10.13 2.95 10.35 2.98
9.52
3.20
9.73
3.23
9.25
3.32
9.47
3.34
8.81
3.52
9.03
3.55
8.49
3.44
8.69
3.44
7.88
2.90
8.05
2.90
10.53 2.99 10.75 3.02
10.26 3.09 10.48 3.12
9.64
3.35
9.86
3.38
9.37
3.48
9.59
3.50
8.90
3.59
9.10
3.59
8.58
3.44
8.77
3.44
7.99
2.90
8.15
2.90
9.73
2.77
9.93
2.80
9.48
2.87
9.69
2.90
8.90
3.11
9.11
3.14
8.66
3.23
8.86
3.25
8.24
3.43
8.45
3.45
7.97
3.44
8.17
3.44
7.46
2.90
7.62
2.90
10.40 2.91 10.62 2.94
10.13 3.01 10.35 3.04
9.52
3.27
9.73
3.30
9.25
3.39
9.47
3.41
8.81
3.59
9.02
3.59
8.48
3.44
8.68
3.44
7.89
2.90
8.06
2.90
10.52 2.98 10.74 3.01
10.25 3.08 10.47 3.11
9.63
3.34
9.85
3.37
9.36
3.47
9.58
3.49
8.89
3.59
9.10
3.59
8.57
3.44
8.77
3.44
7.98
2.90
8.14
2.90
10.54 2.66 10.76 2.68
10.27 2.75 10.49 2.77
9.65
2.98
9.87
3.01
9.38
3.09
9.60
3.11
8.93
3.28
9.15
3.30
8.66
3.40
8.88
3.43
7.99
2.90
8.17
2.90
9.47
2.48
9.66
2.51
9.22
2.57
9.42
2.59
8.66
2.79
8.86
2.81
8.42
2.89
8.62
2.91
8.02
3.07
8.22
3.09
7.78
3.18
7.98
3.21
7.32
2.90
7.49
2.90
9.73
2.77
9.93
2.80
9.48
2.87
9.69
2.90
8.90
3.11
9.11
3.14
8.66
3.23
8.86
3.25
8.24
3.43
8.45
3.45
7.97
3.44
8.17
3.44
7.46
2.90
7.62
2.90

22C
TC
PI
kW
kW
11.04 2.89
10.79 2.98
10.18 3.23
9.92
3.34
9.49
3.54
9.13
3.44
8.41
2.90
11.27 2.96
11.01 3.06
10.39 3.31
10.12 3.42
9.66
3.59
9.28
3.44
8.54
2.90
11.41 3.10
11.15 3.20
10.52 3.47
10.25 3.59
9.72
3.59
9.36
3.44
8.64
2.90
10.54 2.88
10.30 2.97
9.72
3.22
9.47
3.33
9.06
3.53
8.74
3.44
8.10
2.90
11.27 3.02
11.01 3.12
10.39 3.38
10.12 3.50
9.63
3.59
9.26
3.44
8.55
2.90
11.40 3.09
11.13 3.19
10.51 3.46
10.24 3.58
9.71
3.59
9.35
3.44
8.63
2.90
11.43 2.75
11.16 2.85
10.53 3.08
10.26 3.19
9.82
3.38
9.51
3.44
8.68
2.90
10.26 2.58
10.02 2.66
9.46
2.88
9.22
2.98
8.81
3.16
8.57
3.27
7.98
2.90
10.54 2.88
10.30 2.97
9.72
3.22
9.47
3.33
9.06
3.53
8.74
3.44
8.10
2.90

24C
TC
PI
kW
kW
11.47 2.94
11.21 3.04
10.61 3.28
10.35 3.39
9.91
3.59
9.51
3.44
8.73
2.90
11.71 3.01
11.44 3.11
10.83 3.36
10.56 3.48
10.07 3.59
9.66
3.44
8.87
2.90
11.86 3.16
11.59 3.26
10.96 3.52
10.69 3.64
10.11 3.59
9.74
3.44
8.96
2.90
10.95 2.93
10.71 3.03
10.13 3.27
9.88
3.38
9.47
3.58
9.11
3.44
8.41
2.90
11.71 3.08
11.44 3.18
10.83 3.43
10.56 3.55
10.03 3.59
9.64
3.44
8.87
2.90
11.84 3.15
11.58 3.25
10.95 3.51
10.68 3.63
10.11 3.59
9.73
3.44
8.95
2.90
11.87 2.80
11.60 2.90
10.97 3.13
10.71 3.24
10.26 3.43
9.91
3.44
9.02
2.90
10.66 2.62
10.42 2.71
9.85
2.93
9.61
3.03
9.21
3.21
8.97
3.32
8.30
2.90
10.95 2.93
10.71 3.03
10.13 3.27
9.88
3.38
9.47
3.58
9.11
3.44
8.41
2.90

101

Capacity Tables

Combination
(Capacity)
2.0+2.5+2.5+5.0

2.0+2.5+2.5+6.0

2.0+2.5+2.5+7.1

2.0+2.5+3.5+3.5

2.0+2.5+3.5+5.0

2.0+2.5+3.5+6.0

2.0+2.5+5.0+5.0

2.0+3.5+3.5+3.5

2.0+3.5+3.5+5.0

102

EDAU12-722

Outdoor
air temp.
CDB
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0

14C
TC
PI
kW
kW
9.45
2.74
9.18
2.84
8.57
3.09
8.31
3.21
7.87
3.42
7.60
3.44
7.14
2.90
9.60
2.81
9.33
2.91
8.71
3.17
8.44
3.29
8.00
3.50
7.72
3.44
7.25
2.90
9.66
2.88
9.39
2.98
8.76
3.24
8.49
3.36
8.05
3.58
7.77
3.44
7.31
2.90
9.14
2.79
8.89
2.89
8.30
3.15
8.04
3.27
7.62
3.48
7.37
3.44
6.98
2.90
9.60
2.87
9.33
2.97
8.71
3.23
8.44
3.35
8.00
3.57
7.72
3.44
7.27
2.90
9.66
2.87
9.39
2.97
8.76
3.23
8.49
3.35
8.05
3.57
7.77
3.44
7.31
2.90
9.66
2.56
9.39
2.65
8.76
2.88
8.49
2.99
8.05
3.18
7.78
3.30
7.27
2.90
9.28
2.79
9.03
2.89
8.42
3.15
8.17
3.27
7.74
3.48
7.48
3.44
7.06
2.90
9.66
2.87
9.39
2.97
8.76
3.23
8.49
3.35
8.05
3.57
7.77
3.44
7.31
2.90

16C
TC
PI
kW
kW
9.88
2.80
9.62
2.90
9.00
3.15
8.74
3.26
8.30
3.47
8.01
3.44
7.49
2.90
10.04 2.87
9.77
2.97
9.15
3.22
8.88
3.34
8.44
3.55
8.13
3.44
7.60
2.90
10.10 2.93
9.83
3.04
9.20
3.30
8.94
3.42
8.48
3.59
8.18
3.44
7.65
2.90
9.56
2.85
9.31
2.95
8.72
3.20
8.46
3.32
8.04
3.53
7.77
3.44
7.31
2.90
10.04 2.92
9.77
3.03
9.15
3.29
8.88
3.41
8.43
3.59
8.13
3.44
7.61
2.90
10.10 2.92
9.83
3.03
9.20
3.29
8.94
3.41
8.48
3.59
8.18
3.44
7.65
2.90
10.10 2.61
9.83
2.70
9.20
2.93
8.94
3.04
8.49
3.23
8.22
3.35
7.64
2.90
9.71
2.85
9.45
2.95
8.85
3.20
8.59
3.32
8.16
3.53
7.88
3.44
7.40
2.90
10.10 2.92
9.83
3.03
9.20
3.29
8.94
3.41
8.48
3.59
8.18
3.44
7.65
2.90

Indoor air temp.:CWB


18C
19C
TC
PI
TC
PI
kW
kW
kW
kW
10.31 2.85 10.53 2.88
10.05 2.95 10.26 2.98
9.44
3.20
9.65
3.23
9.17
3.32
9.39
3.34
8.74
3.52
8.95
3.55
8.42
3.44
8.62
3.44
7.83
2.90
8.00
2.90
10.48 2.92 10.69 2.95
10.21 3.02 10.43 3.05
9.59
3.28
9.81
3.30
9.32
3.40
9.54
3.42
8.87
3.59
9.08
3.59
8.54
3.44
8.74
3.44
7.94
2.90
8.11
2.90
10.54 2.99 10.76 3.02
10.27 3.09 10.49 3.12
9.65
3.35
9.87
3.38
9.38
3.48
9.60
3.50
8.91
3.59
9.11
3.59
8.58
3.44
8.78
3.44
7.99
2.90
8.16
2.90
9.98
2.90 10.19 2.93
9.73
3.00
9.94
3.03
9.13
3.26
9.34
3.29
8.88
3.38
9.09
3.40
8.46
3.59
8.66
3.59
8.16
3.44
8.36
3.44
7.64
2.90
7.80
2.90
10.48 2.98 10.69 3.01
10.21 3.08 10.43 3.11
9.59
3.34
9.81
3.37
9.32
3.47
9.54
3.49
8.85
3.59
9.06
3.59
8.54
3.44
8.73
3.44
7.95
2.90
8.12
2.90
10.54 2.98 10.76 3.01
10.27 3.08 10.49 3.11
9.65
3.34
9.87
3.37
9.38
3.47
9.60
3.49
8.91
3.59
9.12
3.59
8.58
3.44
8.78
3.44
7.99
2.90
8.16
2.90
10.54 2.66 10.76 2.68
10.27 2.75 10.49 2.77
9.65
2.98
9.87
3.01
9.38
3.09
9.60
3.11
8.93
3.28
9.15
3.30
8.66
3.40
8.88
3.43
7.99
2.90
8.17
2.90
10.13 2.90 10.35 2.93
9.88
3.00 10.09 3.03
9.28
3.26
9.49
3.29
9.02
3.38
9.23
3.40
8.59
3.59
8.79
3.59
8.28
3.44
8.47
3.44
7.73
2.90
7.90
2.90
10.54 2.98 10.76 3.01
10.27 3.08 10.49 3.11
9.65
3.34
9.87
3.37
9.38
3.47
9.60
3.49
8.91
3.59
9.12
3.59
8.58
3.44
8.78
3.44
7.99
2.90
8.16
2.90

22C
TC
PI
kW
kW
11.18 2.96
10.91 3.06
10.30 3.31
10.04 3.42
9.58
3.59
9.20
3.44
8.49
2.90
11.35 3.03
11.09 3.13
10.47 3.39
10.20 3.51
9.70
3.59
9.32
3.44
8.60
2.90
11.43 3.10
11.16 3.20
10.53 3.47
10.26 3.59
9.73
3.59
9.37
3.44
8.65
2.90
10.82 3.01
10.56 3.11
9.97
3.37
9.72
3.49
9.26
3.59
8.92
3.44
8.28
2.90
11.35 3.09
11.09 3.19
10.47 3.46
10.20 3.58
9.67
3.59
9.31
3.44
8.60
2.90
11.43 3.09
11.16 3.19
10.53 3.46
10.26 3.58
9.73
3.59
9.37
3.44
8.65
2.90
11.43 2.75
11.16 2.85
10.53 3.08
10.26 3.19
9.82
3.38
9.51
3.44
8.68
2.90
10.99 3.01
10.73 3.11
10.13 3.37
9.87
3.49
9.40
3.59
9.05
3.44
8.38
2.90
11.43 3.09
11.16 3.19
10.53 3.46
10.26 3.58
9.73
3.59
9.37
3.44
8.65
2.90

24C
TC
PI
kW
kW
11.61 3.01
11.35 3.11
10.73 3.36
10.47 3.48
9.98
3.59
9.58
3.44
8.81
2.90
11.79 3.08
11.53 3.19
10.91 3.44
10.64 3.56
10.10 3.59
9.70
3.44
8.92
2.90
11.87 3.16
11.60 3.26
10.97 3.52
10.71 3.64
10.12 3.59
9.75
3.44
8.96
2.90
11.24 3.07
10.98 3.17
10.39 3.42
10.14 3.54
9.64
3.59
9.29
3.44
8.59
2.90
11.79 3.15
11.53 3.25
10.91 3.51
10.64 3.63
10.07 3.59
9.69
3.44
8.92
2.90
11.87 3.15
11.60 3.25
10.97 3.51
10.71 3.63
10.13 3.59
9.75
3.44
8.96
2.90
11.87 2.80
11.60 2.90
10.97 3.13
10.71 3.24
10.26 3.43
9.91
3.44
9.02
2.90
11.41 3.07
11.15 3.17
10.55 3.42
10.29 3.54
9.79
3.59
9.42
3.44
8.69
2.90
11.87 3.15
11.60 3.25
10.97 3.51
10.71 3.63
10.13 3.59
9.75
3.44
8.96
2.90

SUPER MULTI NX E-Series Heat Pump

EDAU12-722

Combination
(Capacity)
2.5+2.5+2.5+2.5

2.5+2.5+2.5+3.5

2.5+2.5+2.5+5.0

2.5+2.5+2.5+6.0

2.5+2.5+3.5+3.5

2.5+2.5+3.5+5.0

2.5+2.5+3.5+6.0

2.5+3.5+3.5+3.5

2.5+3.5+3.5+5.0

Capacity Tables

Outdoor
air temp.
CDB
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0

SUPER MULTI NX E-Series Heat Pump

14C
TC
PI
kW
kW
8.87
2.67
8.63
2.77
8.05
3.01
7.80
3.12
7.39
3.32
7.15
3.44
6.77
2.90
8.97
2.67
8.72
2.77
8.14
3.01
7.89
3.12
7.48
3.32
7.23
3.44
6.83
2.90
9.53
2.80
9.26
2.90
8.64
3.16
8.38
3.28
7.94
3.49
7.66
3.44
7.21
2.90
9.64
2.87
9.37
2.97
8.74
3.23
8.48
3.35
8.03
3.57
7.75
3.44
7.30
2.90
9.09
2.79
8.84
2.89
8.25
3.15
8.00
3.27
7.58
3.48
7.33
3.44
6.95
2.90
9.64
2.87
9.37
2.97
8.74
3.23
8.48
3.35
8.03
3.57
7.75
3.44
7.30
2.90
9.66
2.87
9.39
2.97
8.76
3.23
8.49
3.35
8.05
3.57
7.77
3.44
7.31
2.90
9.39
2.79
9.13
2.89
8.53
3.15
8.26
3.27
7.83
3.48
7.56
3.44
7.13
2.90
9.66
2.87
9.39
2.97
8.76
3.23
8.49
3.35
8.05
3.57
7.77
3.44
7.31
2.90

16C
TC
PI
kW
kW
9.28
2.72
9.03
2.82
8.46
3.06
8.21
3.18
7.80
3.38
7.55
3.44
7.11
2.90
9.38
2.72
9.13
2.82
8.55
3.06
8.30
3.18
7.89
3.38
7.63
3.44
7.17
2.90
9.96
2.86
9.70
2.96
9.08
3.21
8.82
3.33
8.37
3.54
8.08
3.44
7.55
2.90
10.08 2.92
9.81
3.03
9.19
3.29
8.92
3.41
8.47
3.59
8.17
3.44
7.64
2.90
9.51
2.85
9.26
2.95
8.67
3.20
8.42
3.32
7.99
3.53
7.73
3.44
7.28
2.90
10.08 2.92
9.81
3.03
9.19
3.29
8.92
3.41
8.47
3.59
8.17
3.44
7.64
2.90
10.10 2.92
9.83
3.03
9.20
3.29
8.94
3.41
8.48
3.59
8.18
3.44
7.65
2.90
9.83
2.85
9.56
2.95
8.96
3.20
8.69
3.32
8.26
3.53
7.97
3.44
7.47
2.90
10.10 2.92
9.83
3.03
9.20
3.29
8.94
3.41
8.48
3.59
8.18
3.44
7.65
2.90

Indoor air temp.:CWB


18C
19C
TC
PI
TC
PI
kW
kW
kW
kW
9.68
2.77
9.89
2.80
9.44
2.87
9.64
2.90
8.86
3.11
9.07
3.14
8.62
3.23
8.82
3.25
8.21
3.43
8.41
3.45
7.94
3.44
8.13
3.44
7.43
2.90
7.60
2.90
9.79
2.77 10.00 2.80
9.55
2.87
9.75
2.90
8.96
3.11
9.17
3.14
8.71
3.23
8.92
3.25
8.30
3.43
8.50
3.45
8.03
3.44
8.22
3.44
7.50
2.90
7.67
2.90
10.40 2.91 10.62 2.94
10.13 3.01 10.35 3.04
9.52
3.27
9.73
3.30
9.25
3.39
9.47
3.41
8.81
3.59
9.02
3.59
8.48
3.44
8.68
3.44
7.89
2.90
8.06
2.90
10.52 2.98 10.74 3.01
10.25 3.08 10.47 3.11
9.63
3.34
9.85
3.37
9.36
3.47
9.58
3.49
8.89
3.59
9.10
3.59
8.57
3.44
8.77
3.44
7.98
2.90
8.14
2.90
9.93
2.90 10.13 2.93
9.67
3.00
9.88
3.03
9.08
3.26
9.29
3.29
8.83
3.38
9.04
3.40
8.41
3.59
8.61
3.59
8.12
3.44
8.31
3.44
7.61
2.90
7.77
2.90
10.52 2.98 10.74 3.01
10.25 3.08 10.47 3.11
9.63
3.34
9.85
3.37
9.36
3.47
9.58
3.49
8.89
3.59
9.10
3.59
8.57
3.44
8.77
3.44
7.98
2.90
8.14
2.90
10.54 2.98 10.76 3.01
10.27 3.08 10.49 3.11
9.65
3.34
9.87
3.37
9.38
3.47
9.60
3.49
8.91
3.59
9.12
3.59
8.58
3.44
8.78
3.44
7.99
2.90
8.16
2.90
10.26 2.90 10.47 2.93
9.99
3.00 10.21 3.03
9.39
3.26
9.60
3.29
9.12
3.38
9.34
3.40
8.69
3.59
8.90
3.59
8.37
3.44
8.57
3.44
7.80
2.90
7.97
2.90
10.54 2.98 10.76 3.01
10.27 3.08 10.49 3.11
9.65
3.34
9.87
3.37
9.38
3.47
9.60
3.49
8.91
3.59
9.12
3.59
8.58
3.44
8.78
3.44
7.99
2.90
8.16
2.90

22C
TC
PI
kW
kW
10.50 2.88
10.25 2.97
9.68
3.22
9.43
3.33
9.02
3.53
8.70
3.44
8.07
2.90
10.62 2.88
10.37 2.97
9.79
3.22
9.54
3.33
9.12
3.53
8.79
3.44
8.14
2.90
11.27 3.02
11.01 3.12
10.39 3.38
10.12 3.50
9.63
3.59
9.26
3.44
8.55
2.90
11.40 3.09
11.13 3.19
10.51 3.46
10.24 3.58
9.71
3.59
9.35
3.44
8.63
2.90
10.76 3.01
10.51 3.11
9.92
3.37
9.66
3.49
9.21
3.59
8.88
3.44
8.24
2.90
11.40 3.09
11.13 3.19
10.51 3.46
10.24 3.58
9.71
3.59
9.35
3.44
8.63
2.90
11.43 3.09
11.16 3.19
10.53 3.46
10.26 3.58
9.73
3.59
9.37
3.44
8.65
2.90
11.12 3.01
10.86 3.11
10.25 3.37
9.99
3.49
9.51
3.59
9.15
3.44
8.45
2.90
11.43 3.09
11.16 3.19
10.53 3.46
10.26 3.58
9.73
3.59
9.37
3.44
8.65
2.90

24C
TC
PI
kW
kW
10.90 2.93
10.66 3.03
10.08 3.27
9.84
3.38
9.43
3.58
9.07
3.44
8.38
2.90
11.03 2.93
10.78 3.03
10.20 3.27
9.95
3.38
9.53
3.58
9.16
3.44
8.46
2.90
11.71 3.08
11.44 3.18
10.83 3.43
10.56 3.55
10.03 3.59
9.64
3.44
8.87
2.90
11.84 3.15
11.58 3.25
10.95 3.51
10.68 3.63
10.11 3.59
9.73
3.44
8.95
2.90
11.18 3.07
10.92 3.17
10.33 3.42
10.08 3.54
9.59
3.59
9.25
3.44
8.55
2.90
11.84 3.15
11.58 3.25
10.95 3.51
10.68 3.63
10.11 3.59
9.73
3.44
8.95
2.90
11.87 3.15
11.60 3.25
10.97 3.51
10.71 3.63
10.13 3.59
9.75
3.44
8.96
2.90
11.55 3.07
11.29 3.17
10.68 3.42
10.42 3.54
9.90
3.59
9.52
3.44
8.77
2.90
11.87 3.15
11.60 3.25
10.97 3.51
10.71 3.63
10.13 3.59
9.75
3.44
8.96
2.90

103

Capacity Tables

Combination
(Capacity)
3.5+3.5+3.5+3.5

EDAU12-722

Outdoor
air temp.
CDB
22.0
25.0
32.0
35.0
40.0
43.0
46.0

Symbols

14C
TC
PI
kW
kW
9.10
2.79
8.85
2.89
8.26
3.15
8.01
3.27
7.59
3.48
7.33
3.44
6.95
2.90

16C
TC
PI
kW
kW
9.52
2.85
9.27
2.95
8.68
3.20
8.42
3.32
8.00
3.53
7.74
3.44
7.29
2.90

Indoor air temp.:CWB


18C
19C
TC
PI
TC
PI
kW
kW
kW
kW
9.94
2.90 10.15 2.93
9.68
3.00
9.89
3.03
9.09
3.26
9.30
3.29
8.84
3.38
9.05
3.40
8.42
3.59
8.62
3.59
8.13
3.44
8.32
3.44
7.61
2.90
7.77
2.90

22C
TC
PI
kW
kW
10.77 3.01
10.52 3.11
9.93
3.37
9.68
3.49
9.22
3.59
8.89
3.44
8.25
2.90

24C
TC
PI
kW
kW
11.19 3.07
10.94 3.17
10.35 3.42
10.09 3.54
9.60
3.59
9.26
3.44
8.56
2.90

NOTE:

TC

: Total capacity

(kW)

PI

: Power input

(kW)

Capacities are based on the following conditions.


Corresponding refrigerant piping length : 7.5m
Level difference : 0m
3D052670#1
3D052670#2
3D052670#3
3D052670#4
3D052670#5
3D052670#6
3D052670#7
3D052670#8
3D052670#9

104

SUPER MULTI NX E-Series Heat Pump

EDAU12-722

Capacity Tables

[Heating Capacity 50Hz / 60Hz 220V]


Combination
(Capacity)
2.0

2.5

3.5

5.0

6.0

7.1

2.0+2.0

2.0+2.5

2.0+3.5

Outdoor
air temp.
CWB
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0

SUPER MULTI NX E-Series Heat Pump

16C
TC
PI
kW
kW
2.27
1.04
2.73
1.10
3.19
1.15
3.66
1.20
4.21
1.27
4.58
1.31
5.05
1.36
2.52
1.12
3.03
1.18
3.55
1.24
4.06
1.30
4.68
1.36
5.09
1.41
5.60
1.47
2.73
1.45
3.29
1.52
3.85
1.60
4.41
1.67
5.08
1.76
5.52
1.82
5.78
1.73
3.83
1.80
4.61
1.90
5.39
1.99
6.17
2.08
7.11
2.19
7.74
2.26
8.52
2.36
4.38
2.13
5.28
2.24
6.17
2.34
7.07
2.45
8.14
2.58
8.85
2.67
9.68
2.74
4.81
2.40
5.80
2.53
6.78
2.65
7.76
2.77
8.94
2.92
9.73
3.01
10.58 3.06
3.62
1.50
4.36
1.57
5.10
1.65
5.84
1.73
6.73
1.82
7.32
1.88
8.06
1.95
3.79
1.56
4.56
1.64
5.34
1.72
6.11
1.80
7.04
1.90
7.66
1.96
8.43
2.04
4.07
1.83
4.90
1.92
5.73
2.01
6.56
2.11
7.55
2.22
8.22
2.29
9.05
2.39

18C
TC
PI
kW
kW
2.21
1.06
2.68
1.11
3.14
1.16
3.60
1.21
4.16
1.28
4.53
1.32
4.99
1.37
2.45
1.14
2.97
1.19
3.48
1.25
4.00
1.31
4.61
1.38
5.02
1.42
5.31
1.39
2.67
1.46
3.22
1.54
3.78
1.61
4.34
1.69
5.01
1.77
5.45
1.83
5.48
1.63
3.73
1.82
4.52
1.92
5.30
2.01
6.08
2.10
7.02
2.21
7.64
2.28
8.42
2.38
4.27
2.15
5.17
2.26
6.06
2.37
6.96
2.48
8.03
2.61
8.74
2.69
9.18
2.54
4.69
2.43
5.68
2.55
6.66
2.67
7.64
2.80
8.82
2.94
9.61
3.04
10.04 2.82
3.53
1.51
4.27
1.59
5.01
1.67
5.75
1.74
6.64
1.83
7.23
1.89
7.97
1.97
3.70
1.58
4.47
1.66
5.24
1.74
6.02
1.82
6.94
1.91
7.56
1.98
8.34
2.06
3.97
1.85
4.80
1.94
5.63
2.03
6.46
2.13
7.45
2.24
8.12
2.31
8.95
2.41

Indoor air temp.:CDB


20C
21C
TC
PI
TC
PI
kW
kW
kW
kW
2.16
1.07
2.13
1.07
2.62
1.12
2.59
1.13
3.08
1.17
3.05
1.18
3.54
1.23
3.52
1.23
4.10
1.29
4.07
1.30
4.47
1.33
4.44
1.34
4.93
1.39
4.91
1.39
2.39
1.15
2.36
1.16
2.91
1.21
2.87
1.21
3.42
1.26
3.39
1.27
3.93
1.32
3.90
1.33
4.55
1.39
4.52
1.40
4.96
1.44
4.88
1.42
5.02
1.31
4.88
1.27
2.60
1.48
2.56
1.49
3.15
1.55
3.12
1.56
3.71
1.63
3.68
1.64
4.27
1.70
4.24
1.71
4.94
1.79
4.91
1.80
5.18
1.73
5.04
1.68
5.18
1.53
5.04
1.48
3.64
1.84
3.59
1.85
4.42
1.94
4.37
1.95
5.20
2.03
5.15
2.04
5.98
2.12
5.93
2.13
6.92
2.23
6.87
2.24
7.55
2.30
7.50
2.31
8.15
2.30
7.92
2.21
4.16
2.18
4.11
2.19
5.06
2.28
5.00
2.30
5.95
2.39
5.90
2.40
6.85
2.50
6.79
2.51
7.92
2.63
7.87
2.64
8.64
2.72
8.44
2.64
8.69
2.35
8.44
2.26
4.57
2.46
4.51
2.47
5.56
2.58
5.50
2.59
6.54
2.70
6.48
2.71
7.52
2.82
7.46
2.84
8.70
2.97
8.64
2.98
9.49
3.07
9.23
2.94
9.50
2.60
9.23
2.49
3.44
1.53
3.40
1.54
4.18
1.61
4.14
1.61
4.92
1.68
4.88
1.69
5.66
1.76
5.62
1.77
6.55
1.85
6.50
1.86
7.14
1.91
7.10
1.92
7.88
1.99
7.84
2.00
3.60
1.60
3.55
1.60
4.37
1.68
4.33
1.68
5.15
1.76
5.10
1.76
5.92
1.83
5.87
1.84
6.85
1.93
6.80
1.94
7.47
1.99
7.42
2.00
8.24
2.07
8.19
2.08
3.86
1.87
3.81
1.88
4.69
1.96
4.64
1.97
5.52
2.06
5.47
2.07
6.35
2.15
6.30
2.16
7.35
2.26
7.30
2.27
8.01
2.33
7.96
2.34
8.84
2.43
8.79
2.44

22C
TC
PI
kW
kW
2.10
1.08
2.56
1.13
3.02
1.18
3.49
1.24
4.04
1.30
4.41
1.34
4.88
1.40
2.33
1.16
2.84
1.22
3.36
1.28
3.87
1.33
4.49
1.40
4.74
1.38
4.74
1.23
2.53
1.50
3.09
1.57
3.64
1.64
4.20
1.72
4.87
1.81
4.89
1.62
4.89
1.43
3.54
1.86
4.32
1.96
5.11
2.05
5.89
2.14
6.82
2.25
7.45
2.32
7.69
2.12
4.05
2.20
4.95
2.31
5.84
2.42
6.74
2.52
7.81
2.65
8.19
2.53
8.19
2.17
4.45
2.48
5.44
2.61
6.42
2.73
7.40
2.85
8.58
3.00
8.95
2.81
8.95
2.39
3.35
1.55
4.09
1.62
4.83
1.70
5.57
1.78
6.46
1.87
7.05
1.93
7.79
2.00
3.51
1.61
4.28
1.69
5.05
1.77
5.83
1.85
6.76
1.95
7.37
2.01
8.15
2.09
3.76
1.89
4.59
1.98
5.42
2.08
6.25
2.17
7.25
2.28
7.91
2.35
8.74
2.45

24C
TC
PI
kW
kW
2.04
1.09
2.51
1.14
2.97
1.20
3.43
1.25
3.99
1.31
4.36
1.36
4.63
1.32
2.27
1.17
2.78
1.23
3.29
1.29
3.81
1.35
4.42
1.42
4.45
1.29
4.45
1.15
2.46
1.51
3.02
1.59
3.58
1.66
4.13
1.73
4.59
1.69
4.59
1.51
4.59
1.34
3.45
1.88
4.23
1.98
5.01
2.07
5.79
2.16
6.73
2.27
7.22
2.26
7.22
1.96
3.95
2.22
4.84
2.33
5.73
2.44
6.63
2.55
7.70
2.67
7.70
2.32
7.70
1.99
4.33
2.51
5.32
2.63
6.30
2.75
7.28
2.88
8.41
2.99
8.41
2.56
8.41
2.18
3.26
1.56
4.00
1.64
4.74
1.72
5.48
1.79
6.37
1.88
6.96
1.94
7.70
2.02
3.41
1.63
4.19
1.71
4.96
1.79
5.73
1.87
6.66
1.96
7.28
2.03
8.05
2.11
3.66
1.91
4.49
2.00
5.32
2.10
6.15
2.19
7.15
2.30
7.81
2.38
8.64
2.47

105

Capacity Tables

Combination
(Capacity)
2.0+5.0

2.0+6.0

2.0+7.1

2.5+2.5

2.5+3.5

2.5+5.0

2.5+6.0

2.5+7.1

3.5+3.5

106

EDAU12-722

Outdoor
air temp.
CWB
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0

16C
TC
PI
kW
kW
4.72
1.94
5.68
2.04
6.65
2.14
7.61
2.24
8.77
2.36
9.54
2.44
10.50 2.53
5.17
2.14
6.23
2.24
7.29
2.35
8.34
2.46
9.61
2.59
10.45 2.68
11.51 2.79
5.54
2.30
6.68
2.41
7.81
2.53
8.94
2.65
10.30 2.79
11.20 2.88
12.33 3.00
3.83
1.76
4.61
1.84
5.39
1.93
6.17
2.02
7.11
2.13
7.74
2.20
8.52
2.29
4.56
2.16
5.49
2.27
6.42
2.38
7.35
2.49
8.47
2.62
9.21
2.71
10.14 2.82
5.06
2.15
6.09
2.26
7.12
2.37
8.15
2.48
9.39
2.61
10.22 2.70
11.25 2.81
5.41
2.38
6.51
2.50
7.61
2.62
8.72
2.74
10.04 2.89
10.92 2.98
12.03 3.10
5.54
2.33
6.68
2.45
7.81
2.57
8.94
2.69
10.30 2.83
11.20 2.92
12.33 3.04
4.91
2.52
5.91
2.64
6.91
2.77
7.91
2.90
9.11
3.05
9.92
3.16
10.92 3.28

18C
TC
PI
kW
kW
4.60
1.96
5.57
2.06
6.53
2.16
7.49
2.26
8.65
2.38
9.42
2.46
10.38 2.56
5.04
2.16
6.10
2.27
7.16
2.38
8.21
2.49
9.48
2.62
10.32 2.70
11.38 2.81
5.41
2.32
6.54
2.44
7.67
2.56
8.80
2.67
10.16 2.81
11.06 2.91
12.19 3.02
3.73
1.78
4.52
1.86
5.30
1.95
6.08
2.04
7.02
2.15
7.64
2.22
8.42
2.31
4.45
2.18
5.38
2.29
6.31
2.40
7.24
2.51
8.35
2.65
9.10
2.73
10.03 2.84
4.93
2.18
5.96
2.29
7.00
2.40
8.03
2.50
9.27
2.64
10.09 2.72
11.12 2.83
5.27
2.41
6.37
2.53
7.48
2.65
8.58
2.77
9.90
2.91
10.79 3.01
11.89 3.13
5.41
2.36
6.54
2.47
7.67
2.59
8.80
2.71
10.16 2.85
11.06 2.95
12.19 3.07
4.79
2.54
5.79
2.67
6.79
2.80
7.79
2.93
8.99
3.08
9.79
3.18
10.80 3.31

Indoor air temp.:CDB


20C
21C
TC
PI
TC
PI
kW
kW
kW
kW
4.48
1.98
4.43
2.00
5.45
2.08
5.39
2.09
6.41
2.18
6.35
2.19
7.37
2.28
7.32
2.29
8.53
2.40
8.47
2.41
9.30
2.48
9.24
2.49
10.26 2.58 10.20 2.59
4.92
2.18
4.85
2.20
5.97
2.29
5.91
2.30
7.03
2.40
6.96
2.41
8.08
2.51
8.02
2.52
9.35
2.64
9.29
2.65
10.19 2.73 10.13 2.74
11.25 2.84 11.19 2.85
5.27
2.35
5.20
2.36
6.40
2.47
6.33
2.48
7.53
2.58
7.46
2.60
8.66
2.70
8.59
2.71
10.02 2.84
9.95
2.85
10.93 2.93 10.86 2.95
12.06 3.05 11.99 3.06
3.64
1.79
3.59
1.80
4.42
1.88
4.37
1.89
5.20
1.97
5.15
1.98
5.98
2.06
5.93
2.07
6.92
2.17
6.87
2.18
7.55
2.24
7.50
2.25
8.33
2.33
8.28
2.34
4.33
2.21
4.28
2.22
5.26
2.32
5.21
2.33
6.19
2.43
6.14
2.44
7.12
2.54
7.07
2.55
8.24
2.67
8.18
2.68
8.98
2.76
8.93
2.77
9.91
2.87
9.86
2.88
4.81
2.20
4.74
2.21
5.84
2.31
5.77
2.32
6.87
2.42
6.81
2.43
7.90
2.53
7.84
2.54
9.14
2.66
9.08
2.67
9.97
2.75
9.90
2.76
11.00 2.86 10.93 2.87
5.14
2.43
5.07
2.44
6.24
2.55
6.17
2.57
7.34
2.67
7.28
2.69
8.45
2.79
8.38
2.81
9.77
2.94
9.70
2.95
10.65 3.04 10.59 3.05
11.76 3.16 11.69 3.17
5.27
2.38
5.20
2.39
6.40
2.50
6.33
2.51
7.53
2.62
7.46
2.63
8.66
2.74
8.59
2.75
10.02 2.88
9.95
2.89
10.93 2.97 10.86 2.99
12.06 3.09 11.99 3.11
4.66
2.57
4.60
2.59
5.66
2.70
5.60
2.71
6.67
2.83
6.61
2.84
7.67
2.96
7.61
2.97
8.87
3.11
8.81
3.12
9.67
3.21
9.61
3.23
10.37 3.13 10.07 2.99

22C
TC
PI
kW
kW
4.37
2.01
5.33
2.11
6.29
2.20
7.26
2.30
8.41
2.42
9.18
2.50
10.15 2.60
4.79
2.21
5.84
2.32
6.90
2.42
7.95
2.53
9.22
2.66
10.07 2.75
11.12 2.86
5.13
2.37
6.26
2.49
7.39
2.61
8.52
2.73
9.88
2.87
10.79 2.96
11.92 3.08
3.54
1.81
4.32
1.90
5.11
1.99
5.89
2.08
6.82
2.19
7.45
2.26
8.23
2.35
4.22
2.23
5.15
2.34
6.08
2.45
7.01
2.56
8.13
2.69
8.87
2.78
9.63
2.78
4.68
2.22
5.71
2.33
6.74
2.44
7.78
2.55
9.01
2.68
9.84
2.77
10.87 2.88
5.00
2.46
6.10
2.58
7.21
2.70
8.31
2.82
9.64
2.97
10.52 3.06
11.62 3.18
5.13
2.41
6.26
2.53
7.39
2.65
8.52
2.76
9.88
2.91
10.79 3.00
11.92 3.12
4.54
2.60
5.54
2.73
6.54
2.86
7.55
2.98
8.75
3.14
9.55
3.24
9.78
2.85

24C
TC
PI
kW
kW
4.25
2.03
5.21
2.13
6.18
2.23
7.14
2.32
8.29
2.44
9.07
2.52
10.03 2.62
4.66
2.23
5.71
2.34
6.77
2.45
7.82
2.56
9.09
2.69
9.94
2.77
10.99 2.88
4.99
2.40
6.12
2.52
7.25
2.63
8.39
2.75
9.74
2.89
10.65 2.98
11.78 3.10
3.45
1.83
4.23
1.92
5.01
2.01
5.79
2.10
6.73
2.21
7.35
2.28
8.14
2.37
4.10
2.26
5.04
2.37
5.97
2.48
6.90
2.59
8.01
2.72
8.76
2.81
9.04
2.53
4.55
2.25
5.58
2.36
6.62
2.47
7.65
2.58
8.89
2.71
9.71
2.80
10.75 2.91
4.87
2.48
5.97
2.61
7.07
2.73
8.18
2.85
9.50
2.99
10.38 3.09
11.49 3.21
4.99
2.43
6.12
2.55
7.25
2.67
8.39
2.79
9.74
2.93
10.65 3.03
11.78 3.15
4.42
2.63
5.42
2.76
6.42
2.88
7.42
3.01
8.63
3.17
9.18
3.08
9.18
2.59

SUPER MULTI NX E-Series Heat Pump

EDAU12-722

Combination
(Capacity)
3.5+5.0

3.5+6.0

3.5+7.1

5.0+5.0

5.0+6.0

5.0+7.1

6.0+6.0

6.0+7.1

7.1+7.1

Capacity Tables

Outdoor
air temp.
CWB
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0

SUPER MULTI NX E-Series Heat Pump

16C
TC
PI
kW
kW
5.39
2.32
6.49
2.44
7.59
2.56
8.69
2.68
10.01 2.82
10.89 2.91
11.99 3.03
5.53
2.31
6.66
2.42
7.79
2.54
8.92
2.66
10.28 2.80
11.18 2.89
12.31 3.01
5.55
2.25
6.68
2.36
7.82
2.48
8.95
2.59
10.31 2.73
11.21 2.82
12.35 2.94
5.68
2.23
6.84
2.35
8.00
2.46
9.16
2.57
10.55 2.71
11.48 2.80
12.64 2.91
5.71
2.22
6.87
2.33
8.03
2.44
9.20
2.56
10.59 2.69
11.53 2.78
12.69 2.89
5.72
2.21
6.89
2.32
8.06
2.43
9.22
2.55
10.63 2.68
11.56 2.77
12.73 2.88
5.73
2.25
6.90
2.36
8.06
2.48
9.23
2.59
10.64 2.73
11.57 2.82
12.74 2.94
5.74
2.24
6.92
2.36
8.09
2.47
9.26
2.58
10.67 2.72
11.60 2.81
12.78 2.93
5.76
2.18
6.94
2.30
8.11
2.41
9.29
2.52
10.70 2.65
11.64 2.74
12.81 2.85

18C
TC
PI
kW
kW
5.26
2.35
6.36
2.47
7.45
2.58
8.55
2.70
9.87
2.84
10.75 2.94
11.85 3.06
5.40
2.33
6.52
2.45
7.65
2.57
8.78
2.68
10.14 2.82
11.04 2.92
12.17 3.04
5.41
2.27
6.54
2.39
7.68
2.50
8.81
2.62
10.17 2.75
11.07 2.85
12.21 2.96
5.54
2.26
6.70
2.37
7.86
2.49
9.02
2.60
10.41 2.74
11.34 2.83
12.50 2.94
5.56
2.24
6.73
2.35
7.89
2.47
9.06
2.58
10.45 2.72
11.38 2.81
12.55 2.92
5.58
2.23
6.75
2.35
7.91
2.46
9.08
2.57
10.48 2.71
11.42 2.80
12.58 2.91
5.58
2.27
6.75
2.39
7.92
2.50
9.09
2.62
10.49 2.75
11.43 2.85
12.60 2.96
5.60
2.27
6.77
2.38
7.94
2.49
9.12
2.61
10.52 2.75
11.46 2.84
12.63 2.95
5.62
2.21
6.79
2.32
7.97
2.43
9.14
2.54
10.55 2.68
11.49 2.76
12.67 2.88

Indoor air temp.:CDB


20C
21C
TC
PI
TC
PI
kW
kW
kW
kW
5.12
2.37
5.05
2.39
6.22
2.49
6.15
2.50
7.32
2.61
7.25
2.62
8.42
2.73
8.35
2.74
9.74
2.87
9.67
2.88
10.62 2.96 10.55 2.98
11.72 3.08 11.65 3.10
5.26
2.36
5.19
2.37
6.39
2.47
6.32
2.49
7.52
2.59
7.45
2.60
8.64
2.71
8.58
2.72
10.00 2.85
9.93
2.86
10.90 2.94 10.83 2.96
12.03 3.06 11.96 3.07
5.27
2.30
5.20
2.31
6.41
2.41
6.34
2.43
7.54
2.53
7.47
2.54
8.67
2.64
8.60
2.66
10.03 2.78
9.96
2.79
10.94 2.87 10.87 2.88
12.07 2.99 12.00 3.00
5.40
2.28
5.33
2.30
6.56
2.40
6.49
2.41
7.72
2.51
7.65
2.52
8.88
2.62
8.81
2.64
10.27 2.76 10.20 2.77
11.20 2.85 11.13 2.86
12.36 2.96 12.29 2.98
5.42
2.27
5.35
2.28
6.58
2.38
6.51
2.39
7.75
2.49
7.68
2.50
8.91
2.60
8.84
2.62
10.31 2.74 10.24 2.75
11.24 2.83 11.17 2.84
12.41 2.94 12.33 2.96
5.44
2.26
5.36
2.27
6.60
2.37
6.53
2.38
7.77
2.48
7.70
2.49
8.94
2.60
8.87
2.61
10.34 2.73 10.27 2.74
11.27 2.82 11.20 2.83
12.44 2.93 12.37 2.94
5.44
2.30
5.37
2.31
6.61
2.41
6.54
2.43
7.78
2.53
7.71
2.54
8.95
2.64
8.88
2.66
10.35 2.78 10.28 2.79
11.28 2.87 11.21 2.88
12.45 2.99 12.38 3.00
5.46
2.29
5.39
2.30
6.63
2.40
6.56
2.42
7.80
2.52
7.73
2.53
8.97
2.63
8.90
2.65
10.38 2.77 10.31 2.78
11.32 2.86 11.25 2.87
12.49 2.98 12.42 2.99
5.47
2.23
5.40
2.25
6.65
2.34
6.58
2.36
7.82
2.46
7.75
2.47
9.00
2.57
8.93
2.58
10.41 2.70 10.34 2.71
11.35 2.79 11.28 2.80
12.53 2.90 12.45 2.91

22C
TC
PI
kW
kW
4.99
2.40
6.09
2.52
7.19
2.64
8.29
2.75
9.61
2.90
10.49 2.99
11.59 3.11
5.12
2.38
6.25
2.50
7.38
2.62
8.51
2.73
9.86
2.88
10.77 2.97
11.89 3.09
5.13
2.32
6.27
2.44
7.40
2.55
8.53
2.67
9.89
2.81
10.80 2.90
11.93 3.01
5.26
2.31
6.42
2.42
7.58
2.53
8.74
2.65
10.13 2.78
11.06 2.88
12.22 2.99
5.28
2.29
6.44
2.40
7.61
2.52
8.77
2.63
10.17 2.76
11.10 2.85
12.26 2.97
5.29
2.28
6.46
2.39
7.63
2.51
8.80
2.62
10.20 2.75
11.13 2.84
12.30 2.96
5.30
2.32
6.47
2.44
7.64
2.55
8.80
2.67
10.21 2.81
11.14 2.90
12.31 3.01
5.31
2.32
6.49
2.43
7.66
2.54
8.83
2.66
10.24 2.79
11.17 2.89
12.35 3.00
5.33
2.26
6.50
2.37
7.68
2.48
8.86
2.59
10.27 2.72
11.21 2.81
12.38 2.92

24C
TC
PI
kW
kW
4.85
2.43
5.95
2.54
7.05
2.66
8.15
2.78
9.47
2.92
10.35 3.02
11.45 3.13
4.98
2.41
6.11
2.53
7.24
2.64
8.37
2.76
9.72
2.90
10.63 3.00
11.76 3.11
5.00
2.35
6.13
2.46
7.26
2.58
8.39
2.69
9.75
2.83
10.66 2.92
11.79 3.04
5.12
2.33
6.28
2.45
7.44
2.56
8.59
2.67
9.99
2.81
10.91 2.90
12.07 3.01
5.14
2.32
6.30
2.43
7.46
2.54
8.63
2.65
10.03 2.79
10.96 2.88
12.12 2.99
5.15
2.31
6.32
2.42
7.49
2.53
8.65
2.64
10.05 2.78
10.99 2.87
12.16 2.98
5.16
2.35
6.32
2.46
7.49
2.58
8.66
2.69
10.06 2.83
11.00 2.92
12.17 3.04
5.17
2.34
6.34
2.45
7.51
2.57
8.69
2.68
10.09 2.82
11.03 2.91
12.20 3.03
5.19
2.28
6.36
2.39
7.54
2.50
8.71
2.62
10.12 2.75
11.06 2.84
12.24 2.95

107

Capacity Tables

Combination
(Capacity)
2.0+2.0+2.0

2.0+2.0+2.5

2.0+2.0+3.5

2.0+2.0+5.0

2.0+2.0+6.0

2.0+2.0+7.1

2.0+2.5+2.5

2.0+2.5+3.5

2.0+2.5+5.0

108

EDAU12-722

Outdoor
air temp.
CWB
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0

16C
TC
PI
kW
kW
4.45
1.76
5.36
1.84
6.27
1.93
7.18
2.02
8.27
2.13
9.00
2.20
9.91
2.29
4.78
1.91
5.76
2.01
6.73
2.10
7.71
2.20
8.88
2.32
9.66
2.40
10.63 2.49
5.18
2.14
6.24
2.24
7.30
2.35
8.36
2.46
9.63
2.59
10.48 2.68
11.53 2.79
5.71
2.22
6.88
2.33
8.04
2.44
9.21
2.56
10.60 2.69
11.54 2.78
12.70 2.89
5.73
2.20
6.90
2.31
8.06
2.42
9.23
2.54
10.64 2.67
11.57 2.76
12.74 2.87
5.75
2.19
6.92
2.30
8.10
2.42
9.27
2.53
10.68 2.66
11.62 2.75
12.79 2.86
4.78
1.89
5.76
1.99
6.73
2.09
7.71
2.18
8.88
2.30
9.66
2.37
10.63 2.47
5.18
2.11
6.24
2.22
7.30
2.33
8.36
2.43
9.63
2.56
10.48 2.65
11.53 2.76
5.71
2.22
6.88
2.33
8.04
2.44
9.21
2.56
10.60 2.69
11.54 2.78
12.70 2.89

18C
TC
PI
kW
kW
4.34
1.78
5.25
1.86
6.16
1.95
7.07
2.04
8.16
2.15
8.89
2.22
9.80
2.31
4.66
1.93
5.64
2.03
6.61
2.12
7.59
2.22
8.76
2.34
9.54
2.42
10.52 2.51
5.06
2.16
6.11
2.27
7.17
2.38
8.23
2.49
9.50
2.62
10.35 2.70
11.40 2.81
5.57
2.24
6.73
2.35
7.90
2.47
9.06
2.58
10.46 2.72
11.39 2.81
12.56 2.92
5.58
2.23
6.75
2.34
7.92
2.45
9.09
2.56
10.49 2.70
11.43 2.79
12.60 2.90
5.61
2.22
6.78
2.33
7.95
2.44
9.13
2.55
10.53 2.69
11.47 2.77
12.65 2.89
4.66
1.91
5.64
2.01
6.61
2.11
7.59
2.20
8.76
2.32
9.54
2.40
10.52 2.49
5.06
2.14
6.11
2.24
7.17
2.35
8.23
2.46
9.50
2.59
10.35 2.67
11.40 2.78
5.57
2.24
6.73
2.35
7.90
2.47
9.06
2.58
10.46 2.72
11.39 2.81
12.56 2.92

Indoor air temp.:CDB


20C
21C
TC
PI
TC
PI
kW
kW
kW
kW
4.23
1.79
4.18
1.80
5.14
1.88
5.09
1.89
6.05
1.97
5.99
1.98
6.96
2.06
6.90
2.07
8.05
2.17
7.99
2.18
8.78
2.24
8.72
2.25
9.69
2.33
9.63
2.34
4.54
1.95
4.48
1.96
5.52
2.05
5.46
2.06
6.49
2.15
6.43
2.16
7.47
2.24
7.41
2.25
8.64
2.36
8.58
2.37
9.42
2.44
9.36
2.45
10.40 2.53 10.34 2.55
4.93
2.18
4.86
2.20
5.98
2.29
5.92
2.30
7.04
2.40
6.98
2.41
8.10
2.51
8.04
2.52
9.37
2.64
9.31
2.65
10.22 2.73 10.15 2.74
11.27 2.84 11.21 2.85
5.43
2.27
5.35
2.28
6.59
2.38
6.52
2.39
7.76
2.49
7.69
2.50
8.92
2.60
8.85
2.62
10.32 2.74 10.25 2.75
11.25 2.83 11.18 2.84
12.42 2.94 12.35 2.96
5.44
2.25
5.37
2.26
6.61
2.36
6.54
2.37
7.78
2.47
7.71
2.49
8.95
2.59
8.88
2.60
10.35 2.72 10.28 2.73
11.28 2.81 11.21 2.82
12.45 2.92 12.38 2.93
5.46
2.24
5.39
2.25
6.64
2.35
6.56
2.37
7.81
2.46
7.74
2.48
8.98
2.58
8.91
2.59
10.39 2.71 10.32 2.72
11.33 2.80 11.26 2.81
12.50 2.91 12.43 2.92
4.54
1.94
4.48
1.95
5.52
2.03
5.46
2.04
6.49
2.13
6.43
2.14
7.47
2.22
7.41
2.23
8.64
2.34
8.58
2.35
9.42
2.42
9.36
2.43
10.40 2.51 10.34 2.52
4.93
2.16
4.86
2.17
5.98
2.27
5.92
2.28
7.04
2.37
6.98
2.39
8.10
2.48
8.04
2.49
9.37
2.61
9.31
2.62
10.22 2.70 10.15 2.71
11.27 2.80 11.21 2.82
5.43
2.27
5.35
2.28
6.59
2.38
6.52
2.39
7.76
2.49
7.69
2.50
8.92
2.60
8.85
2.62
10.32 2.74 10.25 2.75
11.25 2.83 11.18 2.84
12.42 2.94 12.35 2.96

22C
TC
PI
kW
kW
4.12
1.81
5.03
1.90
5.94
1.99
6.85
2.08
7.94
2.19
8.67
2.26
9.58
2.35
4.42
1.97
5.40
2.07
6.37
2.17
7.35
2.26
8.52
2.38
9.30
2.46
10.28 2.56
4.80
2.21
5.85
2.32
6.91
2.42
7.97
2.53
9.24
2.66
10.09 2.75
11.15 2.86
5.28
2.29
6.45
2.40
7.61
2.52
8.78
2.63
10.18 2.76
11.11 2.85
12.28 2.97
5.30
2.27
6.47
2.39
7.64
2.50
8.80
2.61
10.21 2.74
11.14 2.83
12.31 2.95
5.32
2.27
6.49
2.38
7.67
2.49
8.84
2.60
10.25 2.73
11.19 2.82
12.36 2.94
4.42
1.96
5.40
2.05
6.37
2.15
7.35
2.25
8.52
2.36
9.30
2.44
10.28 2.53
4.80
2.18
5.85
2.29
6.91
2.40
7.97
2.50
9.24
2.63
10.09 2.72
11.15 2.83
5.28
2.29
6.45
2.40
7.61
2.52
8.78
2.63
10.18 2.76
11.11 2.85
12.28 2.97

24C
TC
PI
kW
kW
4.01
1.83
4.92
1.92
5.83
2.01
6.74
2.10
7.83
2.21
8.55
2.28
9.46
2.37
4.30
1.99
5.28
2.09
6.26
2.19
7.23
2.29
8.40
2.40
9.18
2.48
10.16 2.58
4.67
2.23
5.73
2.34
6.78
2.45
7.84
2.56
9.11
2.69
9.96
2.77
11.02 2.88
5.14
2.32
6.31
2.43
7.47
2.54
8.64
2.65
10.04 2.79
10.97 2.88
12.13 2.99
5.16
2.30
6.32
2.41
7.49
2.52
8.66
2.63
10.06 2.77
11.00 2.86
12.17 2.97
5.18
2.29
6.35
2.40
7.52
2.51
8.70
2.62
10.10 2.76
11.04 2.85
12.21 2.96
4.30
1.98
5.28
2.07
6.26
2.17
7.23
2.27
8.40
2.38
9.18
2.46
10.16 2.56
4.67
2.21
5.73
2.31
6.78
2.42
7.84
2.53
9.11
2.66
9.96
2.74
11.02 2.85
5.14
2.32
6.31
2.43
7.47
2.54
8.64
2.65
10.04 2.79
10.97 2.88
12.13 2.99

SUPER MULTI NX E-Series Heat Pump

EDAU12-722

Combination
(Capacity)
2.0+2.5+6.0

2.0+2.5+7.1

2.0+3.5+3.5

2.0+3.5+5.0

2.0+3.5+6.0

2.0+3.5+7.1

2.0+5.0+5.0

2.0+5.0+6.0

2.0+5.0+7.1

Capacity Tables

Outdoor
air temp.
CWB
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0

SUPER MULTI NX E-Series Heat Pump

16C
TC
PI
kW
kW
5.73
2.20
6.90
2.31
8.06
2.42
9.23
2.54
10.64 2.67
11.57 2.76
12.74 2.87
5.75
2.19
6.92
2.30
8.10
2.42
9.27
2.53
10.68 2.66
11.62 2.75
12.79 2.86
5.54
2.26
6.67
2.37
7.80
2.49
8.93
2.60
10.29 2.74
11.19 2.83
12.32 2.95
5.71
2.22
6.88
2.33
8.04
2.44
9.21
2.56
10.60 2.69
11.54 2.78
12.70 2.89
5.73
2.20
6.90
2.31
8.07
2.42
9.24
2.54
10.65 2.67
11.58 2.76
12.75 2.87
5.75
2.19
6.92
2.30
8.10
2.42
9.27
2.53
10.68 2.66
11.62 2.75
12.79 2.86
5.89
2.16
7.09
2.27
8.29
2.38
9.49
2.49
10.93 2.62
11.89 2.71
13.10 2.82
5.90
2.15
7.11
2.26
8.31
2.37
9.52
2.48
10.96 2.61
11.93 2.70
13.13 2.81
5.93
2.14
7.14
2.24
8.35
2.35
9.55
2.46
11.01 2.59
11.97 2.68
13.18 2.79

18C
TC
PI
kW
kW
5.58
2.23
6.75
2.34
7.92
2.45
9.09
2.56
10.49 2.70
11.43 2.79
12.60 2.90
5.61
2.22
6.78
2.33
7.95
2.44
9.13
2.55
10.53 2.69
11.47 2.77
12.65 2.89
5.40
2.28
6.53
2.40
7.66
2.51
8.79
2.63
10.15 2.76
11.05 2.86
12.18 2.97
5.57
2.24
6.73
2.35
7.90
2.47
9.06
2.58
10.46 2.72
11.39 2.81
12.56 2.92
5.59
2.23
6.76
2.34
7.93
2.45
9.10
2.56
10.50 2.70
11.44 2.79
12.61 2.90
5.61
2.22
6.78
2.33
7.95
2.44
9.13
2.55
10.53 2.69
11.47 2.77
12.65 2.89
5.74
2.18
6.94
2.29
8.14
2.40
9.35
2.51
10.79 2.65
11.75 2.73
12.95 2.84
5.76
2.18
6.96
2.29
8.17
2.40
9.37
2.50
10.82 2.64
11.78 2.72
12.99 2.83
5.78
2.16
6.99
2.27
8.20
2.38
9.41
2.49
10.86 2.62
11.83 2.70
13.03 2.81

Indoor air temp.:CDB


20C
21C
TC
PI
TC
PI
kW
kW
kW
kW
5.44
2.25
5.37
2.26
6.61
2.36
6.54
2.37
7.78
2.47
7.71
2.49
8.95
2.59
8.88
2.60
10.35 2.72 10.28 2.73
11.28 2.81 11.21 2.82
12.45 2.92 12.38 2.93
5.46
2.24
5.39
2.25
6.64
2.35
6.56
2.37
7.81
2.46
7.74
2.48
8.98
2.58
8.91
2.59
10.39 2.71 10.32 2.72
11.33 2.80 11.26 2.81
12.50 2.91 12.43 2.92
5.26
2.31
5.19
2.32
6.39
2.42
6.32
2.43
7.52
2.54
7.45
2.55
8.65
2.65
8.58
2.66
10.01 2.79
9.94
2.80
10.91 2.88 10.85 2.89
12.04 3.00 11.98 3.01
5.43
2.27
5.35
2.28
6.59
2.38
6.52
2.39
7.76
2.49
7.69
2.50
8.92
2.60
8.85
2.62
10.32 2.74 10.25 2.75
11.25 2.83 11.18 2.84
12.42 2.94 12.35 2.96
5.45
2.25
5.38
2.26
6.62
2.36
6.55
2.37
7.79
2.47
7.71
2.49
8.96
2.59
8.88
2.60
10.36 2.72 10.29 2.73
11.30 2.81 11.22 2.82
12.47 2.92 12.39 2.93
5.46
2.24
5.39
2.25
6.64
2.35
6.56
2.37
7.81
2.46
7.74
2.48
8.98
2.58
8.91
2.59
10.39 2.71 10.32 2.72
11.33 2.80 11.26 2.81
12.50 2.91 12.43 2.92
5.59
2.21
5.52
2.22
6.80
2.32
6.72
2.33
8.00
2.43
7.92
2.44
9.20
2.54
9.12
2.55
10.64 2.67 10.57 2.68
11.60 2.76 11.53 2.77
12.80 2.87 12.73 2.88
5.61
2.20
5.54
2.21
6.81
2.31
6.74
2.32
8.02
2.42
7.95
2.43
9.22
2.53
9.15
2.54
10.67 2.66 10.60 2.67
11.63 2.75 11.56 2.76
12.84 2.86 12.77 2.87
5.63
2.18
5.56
2.20
6.84
2.29
6.77
2.30
8.05
2.40
7.98
2.41
9.26
2.51
9.18
2.52
10.71 2.64 10.64 2.65
11.68 2.73 11.60 2.74
12.89 2.84 12.81 2.85

22C
TC
PI
kW
kW
5.30
2.27
6.47
2.39
7.64
2.50
8.80
2.61
10.21 2.74
11.14 2.83
12.31 2.95
5.32
2.27
6.49
2.38
7.67
2.49
8.84
2.60
10.25 2.73
11.19 2.82
12.36 2.94
5.12
2.33
6.25
2.45
7.39
2.56
8.52
2.68
9.87
2.82
10.78 2.91
11.91 3.02
5.28
2.29
6.45
2.40
7.61
2.52
8.78
2.63
10.18 2.76
11.11 2.85
12.28 2.97
5.30
2.27
6.47
2.39
7.64
2.50
8.81
2.61
10.22 2.74
11.15 2.83
12.32 2.95
5.32
2.27
6.49
2.38
7.67
2.49
8.84
2.60
10.25 2.73
11.19 2.82
12.36 2.94
5.45
2.23
6.65
2.34
7.85
2.45
9.05
2.56
10.49 2.69
11.45 2.78
12.66 2.89
5.46
2.22
6.67
2.33
7.87
2.44
9.08
2.55
10.52 2.68
11.49 2.77
12.69 2.88
5.48
2.21
6.69
2.32
7.90
2.42
9.11
2.53
10.56 2.66
11.53 2.75
12.74 2.86

24C
TC
PI
kW
kW
5.16
2.30
6.32
2.41
7.49
2.52
8.66
2.63
10.06 2.77
11.00 2.86
12.17 2.97
5.18
2.29
6.35
2.40
7.52
2.51
8.70
2.62
10.10 2.76
11.04 2.85
12.21 2.96
4.99
2.36
6.12
2.47
7.25
2.59
8.38
2.70
9.73
2.84
10.64 2.93
11.77 3.05
5.14
2.32
6.31
2.43
7.47
2.54
8.64
2.65
10.04 2.79
10.97 2.88
12.13 2.99
5.16
2.30
6.33
2.41
7.50
2.52
8.67
2.63
10.07 2.77
11.01 2.86
12.18 2.97
5.18
2.29
6.35
2.40
7.52
2.51
8.70
2.62
10.10 2.76
11.04 2.85
12.21 2.96
5.30
2.26
6.50
2.37
7.70
2.48
8.90
2.59
10.35 2.72
11.31 2.81
12.51 2.92
5.32
2.25
6.52
2.36
7.72
2.47
8.93
2.58
10.38 2.71
11.34 2.80
12.54 2.91
5.33
2.23
6.54
2.34
7.75
2.45
8.96
2.56
10.41 2.69
11.38 2.77
12.59 2.88

109

Capacity Tables

Combination
(Capacity)
2.0+6.0+6.0

2.5+2.5+2.5

2.5+2.5+3.5

2.5+2.5+5.0

2.5+2.5+6.0

2.5+2.5+7.1

2.5+3.5+3.5

2.5+3.5+5.0

2.5+3.5+6.0

110

EDAU12-722

Outdoor
air temp.
CWB
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0

16C
TC
PI
kW
kW
5.93
2.14
7.14
2.24
8.35
2.35
9.55
2.46
11.01 2.59
11.97 2.68
13.18 2.79
5.28
2.22
6.36
2.33
7.44
2.44
8.52
2.56
9.81
2.69
10.68 2.78
11.75 2.89
5.41
2.26
6.52
2.37
7.62
2.49
8.72
2.60
10.05 2.74
10.93 2.83
12.04 2.95
5.71
2.22
6.88
2.33
8.04
2.44
9.21
2.56
10.60 2.69
11.54 2.78
12.70 2.89
5.73
2.20
6.90
2.31
8.06
2.42
9.23
2.54
10.64 2.67
11.57 2.76
12.74 2.87
5.75
2.19
6.92
2.30
8.10
2.42
9.27
2.53
10.68 2.66
11.62 2.75
12.79 2.86
5.54
2.26
6.67
2.37
7.80
2.49
8.93
2.60
10.29 2.74
11.19 2.83
12.32 2.95
5.71
2.22
6.88
2.33
8.04
2.44
9.21
2.56
10.60 2.69
11.54 2.78
12.70 2.89
5.73
2.20
6.90
2.31
8.07
2.42
9.24
2.54
10.65 2.67
11.58 2.76
12.75 2.87

18C
TC
PI
kW
kW
5.78
2.16
6.99
2.27
8.20
2.38
9.41
2.49
10.86 2.62
11.83 2.70
13.03 2.81
5.15
2.24
6.23
2.35
7.31
2.47
8.39
2.58
9.68
2.72
10.54 2.81
11.62 2.92
5.28
2.28
6.38
2.40
7.49
2.51
8.59
2.63
9.92
2.76
10.80 2.86
11.90 2.97
5.57
2.24
6.73
2.35
7.90
2.47
9.06
2.58
10.46 2.72
11.39 2.81
12.56 2.92
5.58
2.23
6.75
2.34
7.92
2.45
9.09
2.56
10.49 2.70
11.43 2.79
12.60 2.90
5.61
2.22
6.78
2.33
7.95
2.44
9.13
2.55
10.53 2.69
11.47 2.77
12.65 2.89
5.40
2.28
6.53
2.40
7.66
2.51
8.79
2.63
10.15 2.76
11.05 2.86
12.18 2.97
5.57
2.24
6.73
2.35
7.90
2.47
9.06
2.58
10.46 2.72
11.39 2.81
12.56 2.92
5.59
2.23
6.76
2.34
7.93
2.45
9.10
2.56
10.50 2.70
11.44 2.79
12.61 2.90

Indoor air temp.:CDB


20C
21C
TC
PI
TC
PI
kW
kW
kW
kW
5.63
2.18
5.56
2.20
6.84
2.29
6.77
2.30
8.05
2.40
7.98
2.41
9.26
2.51
9.18
2.52
10.71 2.64 10.64 2.65
11.68 2.73 11.60 2.74
12.89 2.84 12.81 2.85
5.02
2.27
4.95
2.28
6.10
2.38
6.03
2.39
7.18
2.49
7.11
2.50
8.26
2.60
8.19
2.62
9.55
2.74
9.48
2.75
10.41 2.83 10.35 2.84
11.49 2.94 11.43 2.96
5.14
2.31
5.07
2.32
6.25
2.42
6.18
2.43
7.35
2.54
7.28
2.55
8.45
2.65
8.39
2.66
9.78
2.79
9.71
2.80
10.66 2.88 10.60 2.89
11.77 3.00 11.70 3.01
5.43
2.27
5.35
2.28
6.59
2.38
6.52
2.39
7.76
2.49
7.69
2.50
8.92
2.60
8.85
2.62
10.32 2.74 10.25 2.75
11.25 2.83 11.18 2.84
12.42 2.94 12.35 2.96
5.44
2.25
5.37
2.26
6.61
2.36
6.54
2.37
7.78
2.47
7.71
2.49
8.95
2.59
8.88
2.60
10.35 2.72 10.28 2.73
11.28 2.81 11.21 2.82
12.45 2.92 12.38 2.93
5.46
2.24
5.39
2.25
6.64
2.35
6.56
2.37
7.81
2.46
7.74
2.48
8.98
2.58
8.91
2.59
10.39 2.71 10.32 2.72
11.33 2.80 11.26 2.81
12.50 2.91 12.43 2.92
5.26
2.31
5.19
2.32
6.39
2.42
6.32
2.43
7.52
2.54
7.45
2.55
8.65
2.65
8.58
2.66
10.01 2.79
9.94
2.80
10.91 2.88 10.85 2.89
12.04 3.00 11.98 3.01
5.43
2.27
5.35
2.28
6.59
2.38
6.52
2.39
7.76
2.49
7.69
2.50
8.92
2.60
8.85
2.62
10.32 2.74 10.25 2.75
11.25 2.83 11.18 2.84
12.42 2.94 12.35 2.96
5.45
2.25
5.38
2.26
6.62
2.36
6.55
2.37
7.79
2.47
7.71
2.49
8.96
2.59
8.88
2.60
10.36 2.72 10.29 2.73
11.30 2.81 11.22 2.82
12.47 2.92 12.39 2.93

22C
TC
PI
kW
kW
5.48
2.21
6.69
2.32
7.90
2.42
9.11
2.53
10.56 2.66
11.53 2.75
12.74 2.86
4.89
2.29
5.97
2.40
7.05
2.52
8.12
2.63
9.42
2.76
10.28 2.85
11.36 2.97
5.01
2.33
6.11
2.45
7.22
2.56
8.32
2.68
9.64
2.82
10.53 2.91
11.63 3.02
5.28
2.29
6.45
2.40
7.61
2.52
8.78
2.63
10.18 2.76
11.11 2.85
12.28 2.97
5.30
2.27
6.47
2.39
7.64
2.50
8.80
2.61
10.21 2.74
11.14 2.83
12.31 2.95
5.32
2.27
6.49
2.38
7.67
2.49
8.84
2.60
10.25 2.73
11.19 2.82
12.36 2.94
5.12
2.33
6.25
2.45
7.39
2.56
8.52
2.68
9.87
2.82
10.78 2.91
11.91 3.02
5.28
2.29
6.45
2.40
7.61
2.52
8.78
2.63
10.18 2.76
11.11 2.85
12.28 2.97
5.30
2.27
6.47
2.39
7.64
2.50
8.81
2.61
10.22 2.74
11.15 2.83
12.32 2.95

24C
TC
PI
kW
kW
5.33
2.23
6.54
2.34
7.75
2.45
8.96
2.56
10.41 2.69
11.38 2.77
12.59 2.88
4.76
2.32
5.84
2.43
6.91
2.54
7.99
2.65
9.29
2.79
10.15 2.88
11.23 2.99
4.87
2.36
5.98
2.47
7.08
2.59
8.18
2.70
9.51
2.84
10.39 2.93
11.50 3.05
5.14
2.32
6.31
2.43
7.47
2.54
8.64
2.65
10.04 2.79
10.97 2.88
12.13 2.99
5.16
2.30
6.32
2.41
7.49
2.52
8.66
2.63
10.06 2.77
11.00 2.86
12.17 2.97
5.18
2.29
6.35
2.40
7.52
2.51
8.70
2.62
10.10 2.76
11.04 2.85
12.21 2.96
4.99
2.36
6.12
2.47
7.25
2.59
8.38
2.70
9.73
2.84
10.64 2.93
11.77 3.05
5.14
2.32
6.31
2.43
7.47
2.54
8.64
2.65
10.04 2.79
10.97 2.88
12.13 2.99
5.16
2.30
6.33
2.41
7.50
2.52
8.67
2.63
10.07 2.77
11.01 2.86
12.18 2.97

SUPER MULTI NX E-Series Heat Pump

EDAU12-722

Combination
(Capacity)
2.5+3.5+7.1

2.5+5.0+5.0

2.5+5.0+6.0

2.5+6.0+6.0

3.5+3.5+3.5

3.5+3.5+5.0

3.5+3.5+6.0

3.5+3.5+7.1

3.5+5.0+5.0

Capacity Tables

Outdoor
air temp.
CWB
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0

SUPER MULTI NX E-Series Heat Pump

16C
TC
PI
kW
kW
5.75
2.19
6.92
2.30
8.10
2.42
9.27
2.53
10.68 2.66
11.62 2.75
12.79 2.86
5.89
2.16
7.09
2.27
8.29
2.38
9.49
2.49
10.93 2.62
11.89 2.71
13.10 2.82
5.90
2.15
7.11
2.26
8.31
2.37
9.52
2.48
10.96 2.61
11.93 2.70
13.13 2.81
5.93
2.14
7.14
2.24
8.35
2.35
9.55
2.46
11.01 2.59
11.97 2.68
13.18 2.79
5.54
2.26
6.68
2.37
7.81
2.49
8.94
2.60
10.30 2.74
11.20 2.83
12.33 2.95
5.72
2.21
6.88
2.32
8.05
2.43
9.22
2.55
10.62 2.68
11.55 2.77
12.71 2.88
5.74
2.20
6.91
2.31
8.08
2.42
9.25
2.54
10.66 2.67
11.59 2.76
12.76 2.87
5.75
2.19
6.93
2.30
8.10
2.42
9.28
2.53
10.69 2.66
11.63 2.75
12.80 2.86
5.89
2.16
7.09
2.27
8.29
2.38
9.49
2.49
10.93 2.62
11.89 2.71
13.10 2.82

18C
TC
PI
kW
kW
5.61
2.22
6.78
2.33
7.95
2.44
9.13
2.55
10.53 2.69
11.47 2.77
12.65 2.89
5.74
2.18
6.94
2.29
8.14
2.40
9.35
2.51
10.79 2.65
11.75 2.73
12.95 2.84
5.76
2.18
6.96
2.29
8.17
2.40
9.37
2.50
10.82 2.64
11.78 2.72
12.99 2.83
5.78
2.16
6.99
2.27
8.20
2.38
9.41
2.49
10.86 2.62
11.83 2.70
13.03 2.81
5.41
2.28
6.54
2.40
7.67
2.51
8.80
2.63
10.16 2.76
11.06 2.86
12.19 2.97
5.57
2.23
6.74
2.35
7.91
2.46
9.07
2.57
10.47 2.71
11.41 2.80
12.57 2.91
5.60
2.23
6.77
2.34
7.94
2.45
9.11
2.56
10.51 2.70
11.45 2.79
12.62 2.90
5.61
2.22
6.79
2.33
7.96
2.44
9.13
2.55
10.54 2.69
11.48 2.77
12.66 2.89
5.74
2.18
6.94
2.29
8.14
2.40
9.35
2.51
10.79 2.65
11.75 2.73
12.95 2.84

Indoor air temp.:CDB


20C
21C
TC
PI
TC
PI
kW
kW
kW
kW
5.46
2.24
5.39
2.25
6.64
2.35
6.56
2.37
7.81
2.46
7.74
2.48
8.98
2.58
8.91
2.59
10.39 2.71 10.32 2.72
11.33 2.80 11.26 2.81
12.50 2.91 12.43 2.92
5.59
2.21
5.52
2.22
6.80
2.32
6.72
2.33
8.00
2.43
7.92
2.44
9.20
2.54
9.12
2.55
10.64 2.67 10.57 2.68
11.60 2.76 11.53 2.77
12.80 2.87 12.73 2.88
5.61
2.20
5.54
2.21
6.81
2.31
6.74
2.32
8.02
2.42
7.95
2.43
9.22
2.53
9.15
2.54
10.67 2.66 10.60 2.67
11.63 2.75 11.56 2.76
12.84 2.86 12.77 2.87
5.63
2.18
5.56
2.20
6.84
2.29
6.77
2.30
8.05
2.40
7.98
2.41
9.26
2.51
9.18
2.52
10.71 2.64 10.64 2.65
11.68 2.73 11.60 2.74
12.89 2.84 12.81 2.85
5.27
2.31
5.20
2.32
6.40
2.42
6.33
2.43
7.53
2.54
7.46
2.55
8.66
2.65
8.59
2.66
10.02 2.79
9.95
2.80
10.93 2.88 10.86 2.89
12.06 3.00 11.99 3.01
5.43
2.26
5.36
2.27
6.60
2.37
6.53
2.38
7.76
2.48
7.69
2.49
8.93
2.60
8.86
2.61
10.33 2.73 10.26 2.74
11.26 2.82 11.19 2.83
12.43 2.93 12.36 2.94
5.45
2.25
5.38
2.26
6.62
2.36
6.55
2.37
7.79
2.47
7.72
2.49
8.96
2.59
8.89
2.60
10.37 2.72 10.30 2.73
11.31 2.81 11.24 2.82
12.48 2.92 12.41 2.93
5.47
2.24
5.40
2.25
6.64
2.35
6.57
2.37
7.82
2.46
7.74
2.48
8.99
2.58
8.92
2.59
10.40 2.71 10.33 2.72
11.34 2.80 11.27 2.81
12.51 2.91 12.44 2.92
5.59
2.21
5.52
2.22
6.80
2.32
6.72
2.33
8.00
2.43
7.92
2.44
9.20
2.54
9.12
2.55
10.64 2.67 10.57 2.68
11.60 2.76 11.53 2.77
12.80 2.87 12.73 2.88

22C
TC
PI
kW
kW
5.32
2.27
6.49
2.38
7.67
2.49
8.84
2.60
10.25 2.73
11.19 2.82
12.36 2.94
5.45
2.23
6.65
2.34
7.85
2.45
9.05
2.56
10.49 2.69
11.45 2.78
12.66 2.89
5.46
2.22
6.67
2.33
7.87
2.44
9.08
2.55
10.52 2.68
11.49 2.77
12.69 2.88
5.48
2.21
6.69
2.32
7.90
2.42
9.11
2.53
10.56 2.66
11.53 2.75
12.74 2.86
5.13
2.33
6.26
2.45
7.39
2.56
8.52
2.68
9.88
2.82
10.79 2.91
11.92 3.02
5.29
2.28
6.45
2.39
7.62
2.51
8.79
2.62
10.19 2.75
11.12 2.84
12.29 2.96
5.31
2.27
6.48
2.39
7.65
2.50
8.82
2.61
10.23 2.74
11.16 2.83
12.33 2.95
5.32
2.27
6.50
2.38
7.67
2.49
8.85
2.60
10.26 2.73
11.20 2.82
12.37 2.94
5.45
2.23
6.65
2.34
7.85
2.45
9.05
2.56
10.49 2.69
11.45 2.78
12.66 2.89

24C
TC
PI
kW
kW
5.18
2.29
6.35
2.40
7.52
2.51
8.70
2.62
10.10 2.76
11.04 2.85
12.21 2.96
5.30
2.26
6.50
2.37
7.70
2.48
8.90
2.59
10.35 2.72
11.31 2.81
12.51 2.92
5.32
2.25
6.52
2.36
7.72
2.47
8.93
2.58
10.38 2.71
11.34 2.80
12.54 2.91
5.33
2.23
6.54
2.34
7.75
2.45
8.96
2.56
10.41 2.69
11.38 2.77
12.59 2.88
4.99
2.36
6.12
2.47
7.25
2.59
8.39
2.70
9.74
2.84
10.65 2.93
11.78 3.05
5.15
2.31
6.31
2.42
7.48
2.53
8.65
2.64
10.04 2.78
10.98 2.87
12.14 2.98
5.17
2.30
6.34
2.41
7.51
2.52
8.68
2.63
10.08 2.77
11.02 2.86
12.19 2.97
5.18
2.29
6.35
2.40
7.53
2.51
8.70
2.62
10.11 2.76
11.05 2.85
12.23 2.96
5.30
2.26
6.50
2.37
7.70
2.48
8.90
2.59
10.35 2.72
11.31 2.81
12.51 2.92

111

Capacity Tables

Combination
(Capacity)
3.5+5.0+6.0

2.0+2.0+2.0+2.0

2.0+2.0+2.0+2.5

2.0+2.0+2.0+3.5

2.0+2.0+2.0+5.0

2.0+2.0+2.0+6.0

2.0+2.0+2.0+7.1

2.0+2.0+2.5+2.5

2.0+2.0+2.5+3.5

112

EDAU12-722

Outdoor
air temp.
CWB
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0

16C
TC
PI
kW
kW
5.91
2.14
7.12
2.25
8.32
2.36
9.53
2.47
10.97 2.60
11.94 2.69
13.15 2.80
5.23
2.03
6.30
2.13
7.36
2.24
8.43
2.34
9.71
2.46
10.56 2.55
11.63 2.65
5.31
2.03
6.40
2.13
7.48
2.24
8.56
2.34
9.87
2.46
10.73 2.55
11.82 2.65
5.74
2.20
6.91
2.31
8.08
2.42
9.25
2.54
10.66 2.67
11.59 2.76
12.76 2.87
5.91
2.14
7.12
2.25
8.32
2.36
9.53
2.47
10.97 2.60
11.94 2.69
13.15 2.80
5.93
2.14
7.14
2.24
8.35
2.35
9.56
2.46
11.02 2.59
11.98 2.68
13.19 2.79
5.95
2.13
7.16
2.24
8.38
2.34
9.59
2.45
11.05 2.58
12.02 2.67
13.23 2.78
5.73
2.20
6.90
2.31
8.07
2.42
9.24
2.54
10.65 2.67
11.58 2.76
12.75 2.87
5.74
2.20
6.91
2.31
8.08
2.42
9.25
2.54
10.66 2.67
11.59 2.76
12.76 2.87

18C
TC
PI
kW
kW
5.76
2.17
6.97
2.28
8.17
2.39
9.38
2.50
10.83 2.63
11.79 2.71
13.00 2.82
5.10
2.05
6.17
2.16
7.23
2.26
8.30
2.36
9.58
2.49
10.43 2.57
11.50 2.67
5.18
2.05
6.26
2.16
7.35
2.26
8.43
2.36
9.73
2.49
10.60 2.57
11.68 2.67
5.60
2.23
6.77
2.34
7.94
2.45
9.11
2.56
10.51 2.70
11.45 2.79
12.62 2.90
5.76
2.17
6.97
2.28
8.17
2.39
9.38
2.50
10.83 2.63
11.79 2.71
13.00 2.82
5.78
2.16
6.99
2.27
8.20
2.38
9.42
2.49
10.87 2.62
11.84 2.70
13.05 2.81
5.80
2.15
7.01
2.26
8.23
2.37
9.44
2.48
10.90 2.61
11.87 2.69
13.08 2.80
5.59
2.23
6.76
2.34
7.93
2.45
9.10
2.56
10.50 2.70
11.44 2.79
12.61 2.90
5.60
2.23
6.77
2.34
7.94
2.45
9.11
2.56
10.51 2.70
11.45 2.79
12.62 2.90

Indoor air temp.:CDB


20C
21C
TC
PI
TC
PI
kW
kW
kW
kW
5.61
2.19
5.54
2.20
6.82
2.30
6.75
2.31
8.03
2.41
7.95
2.42
9.23
2.52
9.16
2.53
10.68 2.65 10.61 2.66
11.64 2.74 11.57 2.75
12.85 2.85 12.78 2.86
4.97
2.08
4.90
2.09
6.04
2.18
5.97
2.19
7.10
2.28
7.04
2.29
8.17
2.39
8.10
2.40
9.45
2.51
9.38
2.52
10.30 2.59 10.24 2.60
11.37 2.70 11.31 2.71
5.05
2.08
4.98
2.09
6.13
2.18
6.06
2.19
7.22
2.28
7.15
2.29
8.30
2.39
8.23
2.40
9.60
2.51
9.53
2.52
10.47 2.59 10.40 2.60
11.55 2.70 11.48 2.71
5.45
2.25
5.38
2.26
6.62
2.36
6.55
2.37
7.79
2.47
7.72
2.49
8.96
2.59
8.89
2.60
10.37 2.72 10.30 2.73
11.31 2.81 11.24 2.82
12.48 2.92 12.41 2.93
5.61
2.19
5.54
2.20
6.82
2.30
6.75
2.31
8.03
2.41
7.95
2.42
9.23
2.52
9.16
2.53
10.68 2.65 10.61 2.66
11.64 2.74 11.57 2.75
12.85 2.85 12.78 2.86
5.64
2.18
5.56
2.20
6.85
2.29
6.77
2.30
8.06
2.40
7.98
2.41
9.27
2.51
9.19
2.52
10.72 2.64 10.65 2.65
11.69 2.73 11.61 2.74
12.90 2.84 12.82 2.85
5.65
2.18
5.58
2.19
6.87
2.28
6.79
2.30
8.08
2.39
8.01
2.40
9.29
2.50
9.22
2.51
10.75 2.63 10.68 2.64
11.72 2.72 11.65 2.73
12.93 2.82 12.86 2.84
5.45
2.25
5.38
2.26
6.62
2.36
6.55
2.37
7.79
2.47
7.71
2.49
8.96
2.59
8.88
2.60
10.36 2.72 10.29 2.73
11.30 2.81 11.22 2.82
12.47 2.92 12.39 2.93
5.45
2.25
5.38
2.26
6.62
2.36
6.55
2.37
7.79
2.47
7.72
2.49
8.96
2.59
8.89
2.60
10.37 2.72 10.30 2.73
11.31 2.81 11.24 2.82
12.48 2.92 12.41 2.93

22C
TC
PI
kW
kW
5.47
2.22
6.67
2.32
7.88
2.43
9.09
2.54
10.53 2.67
11.50 2.76
12.70 2.87
4.84
2.10
5.90
2.20
6.97
2.31
8.04
2.41
9.32
2.53
10.17 2.62
11.24 2.72
4.91
2.10
6.00
2.20
7.08
2.31
8.17
2.41
9.47
2.53
10.33 2.62
11.42 2.72
5.31
2.27
6.48
2.39
7.65
2.50
8.82
2.61
10.23 2.74
11.16 2.83
12.33 2.95
5.47
2.22
6.67
2.32
7.88
2.43
9.09
2.54
10.53 2.67
11.50 2.76
12.70 2.87
5.49
2.21
6.70
2.32
7.91
2.42
9.12
2.53
10.57 2.66
11.54 2.75
12.75 2.86
5.50
2.20
6.72
2.31
7.93
2.42
9.14
2.52
10.60 2.65
11.57 2.74
12.79 2.85
5.30
2.27
6.47
2.39
7.64
2.50
8.81
2.61
10.22 2.74
11.15 2.83
12.32 2.95
5.31
2.27
6.48
2.39
7.65
2.50
8.82
2.61
10.23 2.74
11.16 2.83
12.33 2.95

24C
TC
PI
kW
kW
5.32
2.24
6.53
2.35
7.73
2.46
8.94
2.57
10.39 2.70
11.35 2.79
12.56 2.89
4.71
2.12
5.77
2.22
6.84
2.33
7.91
2.43
9.19
2.56
10.04 2.64
11.11 2.74
4.78
2.12
5.87
2.22
6.95
2.33
8.03
2.43
9.33
2.56
10.20 2.64
11.29 2.74
5.17
2.30
6.34
2.41
7.51
2.52
8.68
2.63
10.08 2.77
11.02 2.86
12.19 2.97
5.32
2.24
6.53
2.35
7.73
2.46
8.94
2.57
10.39 2.70
11.35 2.79
12.56 2.89
5.34
2.23
6.55
2.34
7.76
2.45
8.97
2.56
10.42 2.69
11.39 2.77
12.60 2.88
5.35
2.22
6.57
2.33
7.78
2.44
9.00
2.55
10.45 2.68
11.42 2.76
12.64 2.87
5.16
2.30
6.33
2.41
7.50
2.52
8.67
2.63
10.07 2.77
11.01 2.86
12.18 2.97
5.17
2.30
6.34
2.41
7.51
2.52
8.68
2.63
10.08 2.77
11.02 2.86
12.19 2.97

SUPER MULTI NX E-Series Heat Pump

EDAU12-722

Combination
(Capacity)
2.0+2.0+2.5+5.0

2.0+2.0+2.5+6.0

2.0+2.0+2.5+7.1

2.0+2.0+3.5+3.5

2.0+2.0+3.5+5.0

2.0+2.0+3.5+6.0

2.0+2.0+5.0+5.0

2.0+2.5+2.5+2.5

2.0+2.5+2.5+3.5

Capacity Tables

Outdoor
air temp.
CWB
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0

SUPER MULTI NX E-Series Heat Pump

16C
TC
PI
kW
kW
5.91
2.14
7.12
2.25
8.32
2.36
9.53
2.47
10.97 2.60
11.94 2.69
13.15 2.80
5.93
2.14
7.14
2.24
8.35
2.35
9.56
2.46
11.02 2.59
11.98 2.68
13.19 2.79
5.95
2.13
7.16
2.24
8.38
2.34
9.59
2.45
11.05 2.58
12.02 2.67
13.23 2.78
5.74
2.20
6.92
2.31
8.09
2.42
9.26
2.54
10.67 2.67
11.60 2.76
12.78 2.87
5.92
2.14
7.12
2.25
8.33
2.36
9.54
2.47
10.99 2.60
11.95 2.69
13.16 2.80
5.94
2.14
7.15
2.24
8.36
2.35
9.57
2.46
11.03 2.59
12.00 2.68
13.21 2.79
6.09
2.10
7.33
2.20
8.57
2.31
9.81
2.42
11.30 2.54
12.30 2.63
13.54 2.74
5.73
2.20
6.90
2.31
8.07
2.42
9.24
2.54
10.65 2.67
11.58 2.76
12.75 2.87
5.74
2.20
6.91
2.31
8.08
2.42
9.25
2.54
10.66 2.67
11.59 2.76
12.76 2.87

18C
TC
PI
kW
kW
5.76
2.17
6.97
2.28
8.17
2.39
9.38
2.50
10.83 2.63
11.79 2.71
13.00 2.82
5.78
2.16
6.99
2.27
8.20
2.38
9.42
2.49
10.87 2.62
11.84 2.70
13.05 2.81
5.80
2.15
7.01
2.26
8.23
2.37
9.44
2.48
10.90 2.61
11.87 2.69
13.08 2.80
5.60
2.23
6.77
2.34
7.94
2.45
9.12
2.56
10.52 2.70
11.46 2.79
12.63 2.90
5.77
2.17
6.97
2.28
8.18
2.39
9.39
2.50
10.84 2.63
11.80 2.71
13.01 2.82
5.79
2.16
7.00
2.27
8.21
2.38
9.42
2.49
10.88 2.62
11.85 2.70
13.06 2.81
5.94
2.12
7.18
2.23
8.42
2.33
9.66
2.44
11.15 2.57
12.15 2.65
13.39 2.76
5.59
2.23
6.76
2.34
7.93
2.45
9.10
2.56
10.50 2.70
11.44 2.79
12.61 2.90
5.60
2.23
6.77
2.34
7.94
2.45
9.11
2.56
10.51 2.70
11.45 2.79
12.62 2.90

Indoor air temp.:CDB


20C
21C
TC
PI
TC
PI
kW
kW
kW
kW
5.61
2.19
5.54
2.20
6.82
2.30
6.75
2.31
8.03
2.41
7.95
2.42
9.23
2.52
9.16
2.53
10.68 2.65 10.61 2.66
11.64 2.74 11.57 2.75
12.85 2.85 12.78 2.86
5.64
2.18
5.56
2.20
6.85
2.29
6.77
2.30
8.06
2.40
7.98
2.41
9.27
2.51
9.19
2.52
10.72 2.64 10.65 2.65
11.69 2.73 11.61 2.74
12.90 2.84 12.82 2.85
5.65
2.18
5.58
2.19
6.87
2.28
6.79
2.30
8.08
2.39
8.01
2.40
9.29
2.50
9.22
2.51
10.75 2.63 10.68 2.64
11.72 2.72 11.65 2.73
12.93 2.82 12.86 2.84
5.46
2.25
5.39
2.26
6.63
2.36
6.56
2.37
7.80
2.47
7.73
2.49
8.97
2.59
8.90
2.60
10.38 2.72 10.31 2.73
11.32 2.81 11.25 2.82
12.49 2.92 12.42 2.93
5.62
2.19
5.55
2.20
6.83
2.30
6.75
2.31
8.03
2.41
7.96
2.42
9.24
2.52
9.17
2.53
10.69 2.65 10.62 2.66
11.66 2.74 11.58 2.75
12.86 2.85 12.79 2.86
5.64
2.18
5.57
2.20
6.85
2.29
6.78
2.30
8.06
2.40
7.99
2.41
9.28
2.51
9.20
2.52
10.73 2.64 10.66 2.65
11.70 2.73 11.63 2.74
12.91 2.84 12.84 2.85
5.78
2.14
5.71
2.15
7.03
2.25
6.95
2.26
8.27
2.36
8.19
2.37
9.51
2.46
9.43
2.47
11.00 2.59 10.92 2.60
11.99 2.68 11.92 2.69
13.24 2.78 13.16 2.79
5.45
2.25
5.38
2.26
6.62
2.36
6.55
2.37
7.79
2.47
7.71
2.49
8.96
2.59
8.88
2.60
10.36 2.72 10.29 2.73
11.30 2.81 11.22 2.82
12.47 2.92 12.39 2.93
5.45
2.25
5.38
2.26
6.62
2.36
6.55
2.37
7.79
2.47
7.72
2.49
8.96
2.59
8.89
2.60
10.37 2.72 10.30 2.73
11.31 2.81 11.24 2.82
12.48 2.92 12.41 2.93

22C
TC
PI
kW
kW
5.47
2.22
6.67
2.32
7.88
2.43
9.09
2.54
10.53 2.67
11.50 2.76
12.70 2.87
5.49
2.21
6.70
2.32
7.91
2.42
9.12
2.53
10.57 2.66
11.54 2.75
12.75 2.86
5.50
2.20
6.72
2.31
7.93
2.42
9.14
2.52
10.60 2.65
11.57 2.74
12.79 2.85
5.31
2.27
6.49
2.39
7.66
2.50
8.83
2.61
10.24 2.74
11.17 2.83
12.35 2.95
5.47
2.22
6.68
2.32
7.89
2.43
9.09
2.54
10.54 2.67
11.51 2.76
12.72 2.87
5.49
2.21
6.70
2.32
7.92
2.42
9.13
2.53
10.58 2.66
11.55 2.75
12.76 2.86
5.63
2.17
6.87
2.27
8.12
2.38
9.36
2.49
10.85 2.61
11.84 2.70
13.08 2.81
5.30
2.27
6.47
2.39
7.64
2.50
8.81
2.61
10.22 2.74
11.15 2.83
12.32 2.95
5.31
2.27
6.48
2.39
7.65
2.50
8.82
2.61
10.23 2.74
11.16 2.83
12.33 2.95

24C
TC
PI
kW
kW
5.32
2.24
6.53
2.35
7.73
2.46
8.94
2.57
10.39 2.70
11.35 2.79
12.56 2.89
5.34
2.23
6.55
2.34
7.76
2.45
8.97
2.56
10.42 2.69
11.39 2.77
12.60 2.88
5.35
2.22
6.57
2.33
7.78
2.44
9.00
2.55
10.45 2.68
11.42 2.76
12.64 2.87
5.17
2.30
6.34
2.41
7.51
2.52
8.69
2.63
10.09 2.77
11.03 2.86
12.20 2.97
5.33
2.24
6.53
2.35
7.74
2.46
8.95
2.57
10.39 2.70
11.36 2.79
12.57 2.89
5.34
2.23
6.56
2.34
7.77
2.45
8.98
2.56
10.43 2.69
11.40 2.77
12.61 2.88
5.48
2.19
6.72
2.30
7.96
2.40
9.21
2.51
10.70 2.64
11.69 2.72
12.93 2.83
5.16
2.30
6.33
2.41
7.50
2.52
8.67
2.63
10.07 2.77
11.01 2.86
12.18 2.97
5.17
2.30
6.34
2.41
7.51
2.52
8.68
2.63
10.08 2.77
11.02 2.86
12.19 2.97

113

Capacity Tables

Combination
(Capacity)
2.0+2.5+2.5+5.0

2.0+2.5+2.5+6.0

2.0+2.5+2.5+7.1

2.0+2.5+3.5+3.5

2.0+2.5+3.5+5.0

2.0+2.5+3.5+6.0

2.0+2.5+5.0+5.0

2.0+3.5+3.5+3.5

2.0+3.5+3.5+5.0

114

EDAU12-722

Outdoor
air temp.
CWB
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0

16C
TC
PI
kW
kW
5.91
2.14
7.12
2.25
8.32
2.36
9.53
2.47
10.97 2.60
11.94 2.69
13.15 2.80
5.93
2.14
7.14
2.24
8.35
2.35
9.56
2.46
11.02 2.59
11.98 2.68
13.19 2.79
5.95
2.13
7.16
2.24
8.38
2.34
9.59
2.45
11.05 2.58
12.02 2.67
13.23 2.78
5.74
2.20
6.92
2.31
8.09
2.42
9.26
2.54
10.67 2.67
11.60 2.76
12.78 2.87
5.92
2.14
7.12
2.25
8.33
2.36
9.54
2.47
10.99 2.60
11.95 2.69
13.16 2.80
5.94
2.14
7.15
2.24
8.36
2.35
9.57
2.46
11.03 2.59
12.00 2.68
13.21 2.79
6.09
2.10
7.33
2.20
8.57
2.31
9.81
2.42
11.30 2.54
12.30 2.63
13.54 2.74
5.74
2.19
6.92
2.30
8.09
2.42
9.26
2.53
10.67 2.66
11.60 2.75
12.78 2.86
5.92
2.14
7.13
2.25
8.34
2.36
9.55
2.47
11.00 2.60
11.96 2.69
13.17 2.80

18C
TC
PI
kW
kW
5.76
2.17
6.97
2.28
8.17
2.39
9.38
2.50
10.83 2.63
11.79 2.71
13.00 2.82
5.78
2.16
6.99
2.27
8.20
2.38
9.42
2.49
10.87 2.62
11.84 2.70
13.05 2.81
5.80
2.15
7.01
2.26
8.23
2.37
9.44
2.48
10.90 2.61
11.87 2.69
13.08 2.80
5.60
2.23
6.77
2.34
7.94
2.45
9.12
2.56
10.52 2.70
11.46 2.79
12.63 2.90
5.77
2.17
6.97
2.28
8.18
2.39
9.39
2.50
10.84 2.63
11.80 2.71
13.01 2.82
5.79
2.16
7.00
2.27
8.21
2.38
9.42
2.49
10.88 2.62
11.85 2.70
13.06 2.81
5.94
2.12
7.18
2.23
8.42
2.33
9.66
2.44
11.15 2.57
12.15 2.65
13.39 2.76
5.60
2.22
6.77
2.33
7.94
2.44
9.12
2.55
10.52 2.69
11.46 2.77
12.63 2.89
5.77
2.17
6.98
2.28
8.19
2.39
9.40
2.50
10.85 2.63
11.81 2.71
13.02 2.82

Indoor air temp.:CDB


20C
21C
TC
PI
TC
PI
kW
kW
kW
kW
5.61
2.19
5.54
2.20
6.82
2.30
6.75
2.31
8.03
2.41
7.95
2.42
9.23
2.52
9.16
2.53
10.68 2.65 10.61 2.66
11.64 2.74 11.57 2.75
12.85 2.85 12.78 2.86
5.64
2.18
5.56
2.20
6.85
2.29
6.77
2.30
8.06
2.40
7.98
2.41
9.27
2.51
9.19
2.52
10.72 2.64 10.65 2.65
11.69 2.73 11.61 2.74
12.90 2.84 12.82 2.85
5.65
2.18
5.58
2.19
6.87
2.28
6.79
2.30
8.08
2.39
8.01
2.40
9.29
2.50
9.22
2.51
10.75 2.63 10.68 2.64
11.72 2.72 11.65 2.73
12.93 2.82 12.86 2.84
5.46
2.25
5.39
2.26
6.63
2.36
6.56
2.37
7.80
2.47
7.73
2.49
8.97
2.59
8.90
2.60
10.38 2.72 10.31 2.73
11.32 2.81 11.25 2.82
12.49 2.92 12.42 2.93
5.62
2.19
5.55
2.20
6.83
2.30
6.75
2.31
8.03
2.41
7.96
2.42
9.24
2.52
9.17
2.53
10.69 2.65 10.62 2.66
11.66 2.74 11.58 2.75
12.86 2.85 12.79 2.86
5.64
2.18
5.57
2.20
6.85
2.29
6.78
2.30
8.06
2.40
7.99
2.41
9.28
2.51
9.20
2.52
10.73 2.64 10.66 2.65
11.70 2.73 11.63 2.74
12.91 2.84 12.84 2.85
5.78
2.14
5.71
2.15
7.03
2.25
6.95
2.26
8.27
2.36
8.19
2.37
9.51
2.46
9.43
2.47
11.00 2.59 10.92 2.60
11.99 2.68 11.92 2.69
13.24 2.78 13.16 2.79
5.46
2.24
5.39
2.25
6.63
2.35
6.56
2.37
7.80
2.46
7.73
2.48
8.97
2.58
8.90
2.59
10.38 2.71 10.31 2.72
11.32 2.80 11.25 2.81
12.49 2.91 12.42 2.92
5.63
2.19
5.55
2.20
6.83
2.30
6.76
2.31
8.04
2.41
7.97
2.42
9.25
2.52
9.18
2.53
10.70 2.65 10.63 2.66
11.67 2.74 11.59 2.75
12.87 2.85 12.80 2.86

22C
TC
PI
kW
kW
5.47
2.22
6.67
2.32
7.88
2.43
9.09
2.54
10.53 2.67
11.50 2.76
12.70 2.87
5.49
2.21
6.70
2.32
7.91
2.42
9.12
2.53
10.57 2.66
11.54 2.75
12.75 2.86
5.50
2.20
6.72
2.31
7.93
2.42
9.14
2.52
10.60 2.65
11.57 2.74
12.79 2.85
5.31
2.27
6.49
2.39
7.66
2.50
8.83
2.61
10.24 2.74
11.17 2.83
12.35 2.95
5.47
2.22
6.68
2.32
7.89
2.43
9.09
2.54
10.54 2.67
11.51 2.76
12.72 2.87
5.49
2.21
6.70
2.32
7.92
2.42
9.13
2.53
10.58 2.66
11.55 2.75
12.76 2.86
5.63
2.17
6.87
2.27
8.12
2.38
9.36
2.49
10.85 2.61
11.84 2.70
13.08 2.81
5.31
2.27
6.49
2.38
7.66
2.49
8.83
2.60
10.24 2.73
11.17 2.82
12.35 2.94
5.48
2.22
6.69
2.32
7.89
2.43
9.10
2.54
10.55 2.67
11.52 2.76
12.73 2.87

24C
TC
PI
kW
kW
5.32
2.24
6.53
2.35
7.73
2.46
8.94
2.57
10.39 2.70
11.35 2.79
12.56 2.89
5.34
2.23
6.55
2.34
7.76
2.45
8.97
2.56
10.42 2.69
11.39 2.77
12.60 2.88
5.35
2.22
6.57
2.33
7.78
2.44
9.00
2.55
10.45 2.68
11.42 2.76
12.64 2.87
5.17
2.30
6.34
2.41
7.51
2.52
8.69
2.63
10.09 2.77
11.03 2.86
12.20 2.97
5.33
2.24
6.53
2.35
7.74
2.46
8.95
2.57
10.39 2.70
11.36 2.79
12.57 2.89
5.34
2.23
6.56
2.34
7.77
2.45
8.98
2.56
10.43 2.69
11.40 2.77
12.61 2.88
5.48
2.19
6.72
2.30
7.96
2.40
9.21
2.51
10.70 2.64
11.69 2.72
12.93 2.83
5.17
2.29
6.34
2.40
7.51
2.51
8.69
2.62
10.09 2.76
11.03 2.85
12.20 2.96
5.33
2.24
6.54
2.35
7.75
2.46
8.95
2.57
10.40 2.70
11.37 2.79
12.58 2.89

SUPER MULTI NX E-Series Heat Pump

EDAU12-722

Combination
(Capacity)
2.5+2.5+2.5+2.5

2.5+2.5+2.5+3.5

2.5+2.5+2.5+5.0

2.5+2.5+2.5+6.0

2.5+2.5+3.5+3.5

2.5+2.5+3.5+5.0

2.5+2.5+3.5+6.0

2.5+3.5+3.5+3.5

2.5+3.5+3.5+5.0

Capacity Tables

Outdoor
air temp.
CWB
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0

SUPER MULTI NX E-Series Heat Pump

16C
TC
PI
kW
kW
5.73
2.20
6.90
2.31
8.07
2.42
9.24
2.54
10.65 2.67
11.58 2.76
12.75 2.87
5.74
2.20
6.91
2.31
8.08
2.42
9.25
2.54
10.66 2.67
11.59 2.76
12.76 2.87
5.91
2.14
7.12
2.25
8.32
2.36
9.53
2.47
10.97 2.60
11.94 2.69
13.15 2.80
5.93
2.14
7.14
2.24
8.35
2.35
9.56
2.46
11.02 2.59
11.98 2.68
13.19 2.79
5.74
2.20
6.92
2.31
8.09
2.42
9.26
2.54
10.67 2.67
11.60 2.76
12.78 2.87
5.92
2.14
7.12
2.25
8.33
2.36
9.54
2.47
10.99 2.60
11.95 2.69
13.16 2.80
5.94
2.14
7.15
2.24
8.36
2.35
9.57
2.46
11.03 2.59
12.00 2.68
13.21 2.79
5.74
2.19
6.92
2.30
8.09
2.42
9.26
2.53
10.67 2.66
11.60 2.75
12.78 2.86
5.92
2.14
7.13
2.25
8.34
2.36
9.55
2.47
11.00 2.60
11.96 2.69
13.17 2.80

18C
TC
PI
kW
kW
5.59
2.23
6.76
2.34
7.93
2.45
9.10
2.56
10.50 2.70
11.44 2.79
12.61 2.90
5.60
2.23
6.77
2.34
7.94
2.45
9.11
2.56
10.51 2.70
11.45 2.79
12.62 2.90
5.76
2.17
6.97
2.28
8.17
2.39
9.38
2.50
10.83 2.63
11.79 2.71
13.00 2.82
5.78
2.16
6.99
2.27
8.20
2.38
9.42
2.49
10.87 2.62
11.84 2.70
13.05 2.81
5.60
2.23
6.77
2.34
7.94
2.45
9.12
2.56
10.52 2.70
11.46 2.79
12.63 2.90
5.77
2.17
6.97
2.28
8.18
2.39
9.39
2.50
10.84 2.63
11.80 2.71
13.01 2.82
5.79
2.16
7.00
2.27
8.21
2.38
9.42
2.49
10.88 2.62
11.85 2.70
13.06 2.81
5.60
2.22
6.77
2.33
7.94
2.44
9.12
2.55
10.52 2.69
11.46 2.77
12.63 2.89
5.77
2.17
6.98
2.28
8.19
2.39
9.40
2.50
10.85 2.63
11.81 2.71
13.02 2.82

Indoor air temp.:CDB


20C
21C
TC
PI
TC
PI
kW
kW
kW
kW
5.45
2.25
5.38
2.26
6.62
2.36
6.55
2.37
7.79
2.47
7.71
2.49
8.96
2.59
8.88
2.60
10.36 2.72 10.29 2.73
11.30 2.81 11.22 2.82
12.47 2.92 12.39 2.93
5.45
2.25
5.38
2.26
6.62
2.36
6.55
2.37
7.79
2.47
7.72
2.49
8.96
2.59
8.89
2.60
10.37 2.72 10.30 2.73
11.31 2.81 11.24 2.82
12.48 2.92 12.41 2.93
5.61
2.19
5.54
2.20
6.82
2.30
6.75
2.31
8.03
2.41
7.95
2.42
9.23
2.52
9.16
2.53
10.68 2.65 10.61 2.66
11.64 2.74 11.57 2.75
12.85 2.85 12.78 2.86
5.64
2.18
5.56
2.20
6.85
2.29
6.77
2.30
8.06
2.40
7.98
2.41
9.27
2.51
9.19
2.52
10.72 2.64 10.65 2.65
11.69 2.73 11.61 2.74
12.90 2.84 12.82 2.85
5.46
2.25
5.39
2.26
6.63
2.36
6.56
2.37
7.80
2.47
7.73
2.49
8.97
2.59
8.90
2.60
10.38 2.72 10.31 2.73
11.32 2.81 11.25 2.82
12.49 2.92 12.42 2.93
5.62
2.19
5.55
2.20
6.83
2.30
6.75
2.31
8.03
2.41
7.96
2.42
9.24
2.52
9.17
2.53
10.69 2.65 10.62 2.66
11.66 2.74 11.58 2.75
12.86 2.85 12.79 2.86
5.64
2.18
5.57
2.20
6.85
2.29
6.78
2.30
8.06
2.40
7.99
2.41
9.28
2.51
9.20
2.52
10.73 2.64 10.66 2.65
11.70 2.73 11.63 2.74
12.91 2.84 12.84 2.85
5.46
2.24
5.39
2.25
6.63
2.35
6.56
2.37
7.80
2.46
7.73
2.48
8.97
2.58
8.90
2.59
10.38 2.71 10.31 2.72
11.32 2.80 11.25 2.81
12.49 2.91 12.42 2.92
5.63
2.19
5.55
2.20
6.83
2.30
6.76
2.31
8.04
2.41
7.97
2.42
9.25
2.52
9.18
2.53
10.70 2.65 10.63 2.66
11.67 2.74 11.59 2.75
12.87 2.85 12.80 2.86

22C
TC
PI
kW
kW
5.30
2.27
6.47
2.39
7.64
2.50
8.81
2.61
10.22 2.74
11.15 2.83
12.32 2.95
5.31
2.27
6.48
2.39
7.65
2.50
8.82
2.61
10.23 2.74
11.16 2.83
12.33 2.95
5.47
2.22
6.67
2.32
7.88
2.43
9.09
2.54
10.53 2.67
11.50 2.76
12.70 2.87
5.49
2.21
6.70
2.32
7.91
2.42
9.12
2.53
10.57 2.66
11.54 2.75
12.75 2.86
5.31
2.27
6.49
2.39
7.66
2.50
8.83
2.61
10.24 2.74
11.17 2.83
12.35 2.95
5.47
2.22
6.68
2.32
7.89
2.43
9.09
2.54
10.54 2.67
11.51 2.76
12.72 2.87
5.49
2.21
6.70
2.32
7.92
2.42
9.13
2.53
10.58 2.66
11.55 2.75
12.76 2.86
5.31
2.27
6.49
2.38
7.66
2.49
8.83
2.60
10.24 2.73
11.17 2.82
12.35 2.94
5.48
2.22
6.69
2.32
7.89
2.43
9.10
2.54
10.55 2.67
11.52 2.76
12.73 2.87

24C
TC
PI
kW
kW
5.16
2.30
6.33
2.41
7.50
2.52
8.67
2.63
10.07 2.77
11.01 2.86
12.18 2.97
5.17
2.30
6.34
2.41
7.51
2.52
8.68
2.63
10.08 2.77
11.02 2.86
12.19 2.97
5.32
2.24
6.53
2.35
7.73
2.46
8.94
2.57
10.39 2.70
11.35 2.79
12.56 2.89
5.34
2.23
6.55
2.34
7.76
2.45
8.97
2.56
10.42 2.69
11.39 2.77
12.60 2.88
5.17
2.30
6.34
2.41
7.51
2.52
8.69
2.63
10.09 2.77
11.03 2.86
12.20 2.97
5.33
2.24
6.53
2.35
7.74
2.46
8.95
2.57
10.39 2.70
11.36 2.79
12.57 2.89
5.34
2.23
6.56
2.34
7.77
2.45
8.98
2.56
10.43 2.69
11.40 2.77
12.61 2.88
5.17
2.29
6.34
2.40
7.51
2.51
8.69
2.62
10.09 2.76
11.03 2.85
12.20 2.96
5.33
2.24
6.54
2.35
7.75
2.46
8.95
2.57
10.40 2.70
11.37 2.79
12.58 2.89

115

Capacity Tables

Combination
(Capacity)
3.5+3.5+3.5+3.5

EDAU12-722

Outdoor
air temp.
CWB
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0

Symbols

16C
TC
PI
kW
kW
5.75
2.19
6.92
2.30
8.10
2.42
9.27
2.53
10.68 2.66
11.62 2.75
12.79 2.86

18C
TC
PI
kW
kW
5.61
2.22
6.78
2.33
7.95
2.44
9.13
2.55
10.53 2.69
11.47 2.77
12.65 2.89

Indoor air temp.:CDB


20C
21C
TC
PI
TC
PI
kW
kW
kW
kW
5.46
2.24
5.39
2.25
6.64
2.35
6.56
2.37
7.81
2.46
7.74
2.48
8.98
2.58
8.91
2.59
10.39 2.71 10.32 2.72
11.33 2.80 11.26 2.81
12.50 2.91 12.43 2.92

22C
TC
PI
kW
kW
5.32
2.27
6.49
2.38
7.67
2.49
8.84
2.60
10.25 2.73
11.19 2.82
12.36 2.94

24C
TC
PI
kW
kW
5.18
2.29
6.35
2.40
7.52
2.51
8.70
2.62
10.10 2.76
11.04 2.85
12.21 2.96

NOTE:

TC

: Total capacity

(kW)

PI

: Power input

(kW)

Capacities are based on the following conditions.


Corresponding refrigerant piping length : 7.5m
Level difference : 0m
3D052667#1
3D052667#2
3D052667#3
3D052667#4
3D052667#5
3D052667#6
3D052667#7
3D052667#8
3D052667#9

116

SUPER MULTI NX E-Series Heat Pump

EDAU12-722

Capacity Tables

[Cooling Capacity 50Hz / 60Hz 230V]


Combination
(Capacity)
2.0

2.5

3.5

5.0

6.0

7.1

2.0+2.0

2.0+2.5

2.0+3.5

Outdoor
air temp.
CDB
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0

SUPER MULTI NX E-Series Heat Pump

14C
TC
PI
kW
kW
3.01
0.88
2.92
0.91
2.73
0.99
2.65
1.03
2.51
1.09
2.42
1.14
2.34
1.18
3.22
0.97
3.22
1.04
3.21
1.25
3.11
1.30
2.95
1.38
2.85
1.43
2.75
1.49
3.29
0.74
3.29
0.79
3.29
0.93
3.29
1.01
3.29
1.15
3.29
1.25
3.29
1.37
5.15
1.27
5.15
1.38
5.15
1.67
5.00
1.74
4.74
1.85
4.58
1.92
4.42
1.99
5.60
1.49
5.60
1.61
5.60
1.96
5.60
2.15
5.53
2.48
5.35
2.58
5.16
2.68
6.01
1.62
6.01
1.76
6.01
2.15
6.01
2.36
6.01
2.81
5.88
3.00
5.68
3.03
5.33
1.37
5.18
1.42
4.84
1.55
4.69
1.60
4.44
1.71
4.29
1.77
4.15
1.84
5.76
1.49
5.60
1.54
5.23
1.68
5.07
1.74
4.80
1.85
4.64
1.92
4.48
1.99
6.42
1.73
6.24
1.80
5.82
1.95
5.65
2.03
5.35
2.16
5.17
2.24
4.99
2.33

16C
TC
PI
kW
kW
3.15
0.90
3.06
0.93
2.87
1.01
2.78
1.05
2.64
1.11
2.56
1.15
2.48
1.20
3.70
1.13
3.60
1.17
3.38
1.27
3.28
1.32
3.11
1.40
3.01
1.45
2.92
1.51
4.04
0.93
4.04
1.00
4.04
1.19
4.04
1.29
4.04
1.48
4.04
1.62
4.02
1.76
5.94
1.52
5.79
1.57
5.42
1.71
5.26
1.77
5.00
1.88
4.84
1.95
4.68
2.02
6.88
2.00
6.76
2.11
6.33
2.29
6.14
2.37
5.84
2.52
5.65
2.62
5.47
2.72
7.38
2.21
7.38
2.42
6.96
2.67
6.76
2.77
6.42
2.94
6.22
3.05
6.00
3.03
5.58
1.40
5.43
1.45
5.08
1.57
4.93
1.63
4.69
1.73
4.54
1.80
4.39
1.87
6.03
1.52
5.87
1.57
5.49
1.71
5.33
1.77
5.07
1.88
4.91
1.95
4.75
2.02
6.71
1.77
6.53
1.83
6.12
1.99
5.94
2.06
5.64
2.19
5.46
2.27
5.29
2.36

Indoor air temp.:CWB


18C
19C
TC
PI
TC
PI
kW
kW
kW
kW
3.28
0.91
3.35
0.92
3.20
0.95
3.27
0.95
3.00
1.03
3.07
1.03
2.99
1.07
2.92
1.06
2.78
1.13
2.85
1.14
2.70
1.17
2.77
1.18
2.61
1.21
2.68
1.22
3.87
1.15
3.95
1.16
3.77
1.19
3.85
1.20
3.54
1.29
3.62
1.30
3.44
1.34
3.52
1.35
3.28
1.42
3.36
1.43
3.18
1.48
3.26
1.49
3.08
1.53
3.16
1.54
4.85
1.16
5.28
1.29
4.85
1.25
5.28
1.39
4.85
1.49
4.99
1.52
4.74
1.56
4.85
1.57
4.51
1.66
4.62
1.67
4.38
1.72
4.49
1.73
4.24
1.78
4.35
1.79
6.20
1.55
6.33
1.56
6.05
1.60
6.18
1.61
5.68
1.73
5.81
1.75
5.52
1.80
5.65
1.81
5.26
1.91
5.39
1.92
5.10
1.98
5.23
1.99
4.94
2.05
5.07
2.07
7.25
2.07
7.40
2.09
7.06
2.15
7.21
2.17
6.63
2.33
6.78
2.35
6.45
2.41
6.60
2.43
6.14
2.56
6.29
2.58
5.96
2.66
6.11
2.68
5.77
2.76
5.92
2.77
7.97
2.42
8.14
2.44
7.77
2.50
7.94
2.52
7.30
2.71
7.46
2.73
7.09
2.81
7.26
2.83
6.75
2.98
6.92
3.01
6.55
3.09
6.72
3.12
6.32
3.03
6.48
3.03
5.82
1.43
5.94
1.44
5.67
1.48
5.79
1.49
5.33
1.60
5.45
1.61
5.18
1.66
5.30
1.67
4.93
1.76
5.05
1.77
4.78
1.83
4.91
1.84
4.63
1.89
4.76
1.91
6.29
1.55
6.42
1.56
6.13
1.60
6.26
1.61
5.76
1.73
5.89
1.75
5.60
1.80
5.73
1.81
5.33
1.91
5.46
1.92
5.17
1.98
5.30
1.99
5.01
2.05
5.14
2.07
7.01
1.80
7.15
1.82
6.83
1.86
6.97
1.88
6.41
2.02
6.56
2.04
6.23
2.10
6.38
2.11
5.94
2.22
6.08
2.24
5.76
2.31
5.90
2.32
5.58
2.39
5.73
2.41

22C
TC
PI
kW
kW
3.56
0.95
3.48
0.98
3.28
1.06
3.20
1.10
3.06
1.16
2.97
1.20
2.89
1.25
4.19
1.20
4.09
1.24
3.86
1.34
3.76
1.38
3.60
1.47
3.50
1.52
3.40
1.57
5.77
1.39
5.64
1.44
5.32
1.55
5.19
1.61
4.96
1.71
4.82
1.77
4.69
1.83
6.72
1.60
6.57
1.66
6.20
1.79
6.04
1.86
5.78
1.97
5.62
2.04
5.46
2.11
7.86
2.15
7.67
2.22
7.24
2.41
7.06
2.49
6.75
2.64
6.56
2.73
6.38
2.83
8.64
2.51
8.44
2.59
7.96
2.80
7.76
2.90
7.42
3.07
7.22
3.18
6.94
3.03
6.31
1.48
6.16
1.53
5.81
1.65
5.67
1.71
5.42
1.81
5.27
1.88
5.12
1.95
6.82
1.60
6.66
1.66
6.29
1.79
6.13
1.86
5.86
1.97
5.70
2.04
5.54
2.11
7.59
1.87
7.42
1.93
7.00
2.09
6.82
2.16
6.52
2.29
6.35
2.37
6.17
2.46

24C
TC
PI
kW
kW
3.70
0.96
3.61
1.00
3.42
1.08
3.33
1.11
3.20
1.18
3.11
1.22
3.03
1.26
4.35
1.22
4.25
1.26
4.02
1.36
3.93
1.41
3.76
1.49
3.66
1.54
3.56
1.60
6.00
1.42
5.86
1.46
5.54
1.58
5.41
1.63
5.18
1.73
5.05
1.79
4.91
1.86
6.98
1.63
6.83
1.69
6.46
1.82
6.30
1.88
6.04
2.00
5.88
2.07
5.72
2.14
8.16
2.19
7.97
2.26
7.54
2.45
7.36
2.53
7.05
2.68
6.87
2.77
6.68
2.87
8.98
2.55
8.77
2.64
8.30
2.85
8.10
2.95
7.76
3.12
7.56
3.23
7.23
3.03
6.55
1.51
6.40
1.56
6.06
1.68
5.91
1.74
5.66
1.84
5.52
1.91
5.37
1.97
7.08
1.63
6.92
1.69
6.55
1.82
6.39
1.88
6.12
2.00
5.96
2.07
5.80
2.14
7.89
1.90
7.71
1.97
7.29
2.12
7.11
2.20
6.82
2.33
6.64
2.41
6.46
2.49

117

Capacity Tables

Combination
(Capacity)
2.0+5.0

2.0+6.0

2.0+7.1

2.5+2.5

2.5+3.5

2.5+5.0

2.5+6.0

2.5+7.1

3.5+3.5

118

EDAU12-722

Outdoor
air temp.
CDB
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0

14C
TC
PI
kW
kW
7.34
2.08
7.14
2.15
6.66
2.34
6.46
2.43
6.12
2.59
5.92
2.69
5.71
2.79
7.95
2.43
7.73
2.52
7.21
2.74
6.99
2.84
6.62
3.03
6.40
3.14
6.16
3.03
8.27
2.60
8.04
2.69
7.50
2.93
7.27
3.04
6.89
3.23
6.66
3.35
6.42
3.03
6.21
1.73
6.03
1.80
5.63
1.95
5.46
2.03
5.17
2.16
5.00
2.24
4.83
2.33
6.51
1.88
6.45
2.02
6.02
2.20
5.84
2.28
5.53
2.42
5.35
2.52
5.16
2.61
7.63
2.28
7.42
2.36
6.93
2.57
6.72
2.66
6.36
2.83
6.15
2.94
5.94
3.03
8.08
2.49
7.85
2.58
7.33
2.81
7.11
2.91
6.73
3.10
6.51
3.22
6.26
3.03
8.27
2.60
8.04
2.69
7.50
2.93
7.27
3.04
6.89
3.23
6.66
3.35
6.42
3.03
6.59
1.91
6.59
2.07
6.59
2.58
6.43
2.72
6.09
2.89
5.89
3.00
5.69
3.03

16C
TC
PI
kW
kW
7.68
2.12
7.48
2.19
7.00
2.38
6.80
2.47
6.46
2.63
6.25
2.73
6.05
2.83
8.31
2.48
8.09
2.57
7.57
2.79
7.35
2.89
6.99
3.07
6.77
3.19
6.50
3.03
8.65
2.65
8.42
2.74
7.88
2.98
7.65
3.09
7.27
3.28
7.04
3.40
6.75
3.03
6.49
1.77
6.32
1.83
5.92
1.99
5.74
2.06
5.46
2.19
5.28
2.27
5.11
2.36
6.94
1.99
6.76
2.06
6.33
2.23
6.14
2.32
5.84
2.46
5.65
2.55
5.47
2.65
7.98
2.32
7.77
2.40
7.28
2.61
7.07
2.71
6.71
2.88
6.50
2.98
6.27
3.03
8.45
2.54
8.22
2.63
7.70
2.86
7.48
2.96
7.10
3.15
6.88
3.26
6.60
3.03
8.65
2.65
8.42
2.74
7.88
2.98
7.65
3.09
7.27
3.28
7.04
3.40
6.75
3.03
7.65
2.37
7.44
2.45
6.97
2.67
6.77
2.77
6.43
2.94
6.23
3.05
6.01
3.03

Indoor air temp.:CWB


18C
19C
TC
PI
TC
PI
kW
kW
kW
kW
8.02
2.16
8.18
2.18
7.81
2.23
7.98
2.26
7.34
2.42
7.50
2.44
7.13
2.51
7.30
2.53
6.79
2.67
6.96
2.69
6.59
2.77
6.76
2.79
6.38
2.87
6.55
2.89
8.67
2.53
8.86
2.55
8.45
2.61
8.64
2.64
7.94
2.84
8.12
2.86
7.72
2.94
7.90
2.96
7.35
3.12
7.53
3.14
7.13
3.24
7.31
3.26
6.83
3.03
6.99
3.03
9.03
2.70
9.22
2.72
8.80
2.79
8.99
2.82
8.26
3.03
8.45
3.05
8.03
3.14
8.22
3.16
7.65
3.33
7.84
3.36
7.42
3.46
7.61
3.48
7.08
3.03
7.25
3.03
6.77
1.80
6.92
1.82
6.60
1.86
6.74
1.88
6.20
2.02
6.34
2.04
6.03
2.10
6.17
2.11
5.74
2.22
5.88
2.24
5.57
2.31
5.71
2.32
5.40
2.39
5.54
2.41
7.25
2.02
7.40
2.04
7.06
2.09
7.21
2.11
6.63
2.27
6.78
2.29
6.45
2.35
6.60
2.37
6.14
2.50
6.29
2.52
5.96
2.59
6.11
2.61
5.77
2.69
5.92
2.71
8.33
2.37
8.51
2.39
8.12
2.45
8.30
2.47
7.63
2.65
7.80
2.68
7.42
2.75
7.59
2.77
7.06
2.92
7.24
2.94
6.85
3.03
7.02
3.05
6.61
3.03
6.77
3.03
8.82
2.59
9.00
2.61
8.59
2.68
8.78
2.70
8.07
2.90
8.25
2.93
7.85
3.01
8.03
3.03
7.47
3.20
7.66
3.22
7.25
3.31
7.43
3.34
6.93
3.03
7.09
3.03
9.03
2.70
9.22
2.72
8.80
2.79
8.99
2.82
8.26
3.03
8.45
3.05
8.03
3.14
8.22
3.16
7.65
3.33
7.84
3.36
7.42
3.46
7.61
3.48
7.08
3.03
7.25
3.03
7.98
2.42
8.15
2.44
7.78
2.50
7.95
2.52
7.31
2.71
7.47
2.73
7.10
2.81
7.27
2.83
6.76
2.98
6.93
3.01
6.56
3.09
6.73
3.12
6.33
3.03
6.48
3.03

22C
TC
PI
kW
kW
8.69
2.24
8.48
2.32
8.01
2.51
7.80
2.59
7.46
2.75
7.26
2.85
7.06
2.95
9.40
2.62
9.18
2.71
8.67
2.93
8.45
3.03
8.08
3.22
7.86
3.33
7.47
3.03
9.78
2.80
9.55
2.89
9.02
3.13
8.79
3.24
8.41
3.43
8.18
3.56
7.72
3.03
7.34
1.87
7.17
1.93
6.77
2.09
6.60
2.16
6.31
2.29
6.14
2.37
5.96
2.46
7.86
2.10
7.67
2.17
7.24
2.35
7.06
2.43
6.75
2.57
6.56
2.67
6.38
2.76
9.03
2.45
8.82
2.54
8.33
2.74
8.11
2.84
7.76
3.01
7.55
3.12
7.25
3.03
9.56
2.68
9.33
2.77
8.81
3.00
8.58
3.11
8.21
3.29
7.99
3.41
7.57
3.03
9.78
2.80
9.55
2.89
9.02
3.13
8.79
3.24
8.41
3.43
8.18
3.56
7.72
3.03
8.65
2.51
8.45
2.59
7.98
2.80
7.77
2.90
7.43
3.07
7.23
3.18
6.94
3.03

24C
TC
PI
kW
kW
9.02
2.28
8.82
2.36
8.34
2.55
8.14
2.63
7.80
2.79
7.60
2.89
7.39
2.99
9.77
2.67
9.55
2.76
9.03
2.98
8.81
3.08
8.44
3.26
8.22
3.38
7.78
3.03
10.16 2.85
9.93
2.94
9.40
3.18
9.17
3.29
8.78
3.48
8.55
3.60
8.03
3.03
7.63
1.90
7.46
1.97
7.05
2.12
6.88
2.20
6.59
2.33
6.42
2.41
6.25
2.49
8.16
2.14
7.97
2.21
7.54
2.38
7.36
2.47
7.05
2.61
6.87
2.71
6.68
2.80
9.38
2.50
9.17
2.58
8.68
2.79
8.46
2.88
8.11
3.05
7.90
3.16
7.56
3.03
9.93
2.73
9.70
2.82
9.18
3.05
8.95
3.15
8.58
3.34
8.36
3.46
7.88
3.03
10.16 2.85
9.93
2.94
9.40
3.18
9.17
3.29
8.78
3.48
8.55
3.60
8.03
3.03
8.99
2.55
8.78
2.64
8.31
2.85
8.11
2.95
7.77
3.12
7.57
3.23
7.24
3.03

SUPER MULTI NX E-Series Heat Pump

EDAU12-722

Combination
(Capacity)
3.5+5.0

3.5+6.0

3.5+7.1

5.0+5.0

5.0+6.0

5.0+7.1

6.0+6.0

6.0+7.1

7.1+7.1

Capacity Tables

Outdoor
air temp.
CDB
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0

SUPER MULTI NX E-Series Heat Pump

14C
TC
PI
kW
kW
8.06
2.49
7.83
2.58
7.31
2.81
7.09
2.91
6.71
3.10
6.49
3.22
6.25
3.03
8.59
2.93
8.35
3.03
7.79
3.30
7.56
3.42
7.16
3.64
6.92
3.60
6.68
3.03
8.28
2.60
8.05
2.69
7.51
2.93
7.28
3.04
6.90
3.23
6.67
3.35
6.42
3.03
8.81
2.66
8.57
2.76
8.00
3.00
7.75
3.11
7.34
3.31
7.10
3.44
6.80
3.03
8.84
2.67
8.60
2.77
8.02
3.01
7.78
3.12
7.37
3.32
7.12
3.45
6.82
3.03
9.04
2.79
8.79
2.89
8.21
3.14
7.95
3.26
7.54
3.47
7.28
3.60
6.99
3.03
9.05
2.79
8.80
2.89
8.21
3.14
7.96
3.26
7.54
3.47
7.29
3.60
6.99
3.03
9.07
2.79
8.82
2.89
8.23
3.14
7.98
3.26
7.56
3.47
7.31
3.60
7.01
3.03
9.09
2.79
8.84
2.89
8.25
3.15
8.00
3.27
7.58
3.48
7.33
3.60
7.02
3.03

16C
TC
PI
kW
kW
8.43
2.54
8.20
2.63
7.68
2.86
7.46
2.96
7.08
3.15
6.86
3.26
6.59
3.03
8.98
2.98
8.75
3.09
8.19
3.35
7.95
3.48
7.55
3.70
7.31
3.60
7.07
3.03
8.66
2.65
8.43
2.74
7.89
2.98
7.66
3.09
7.28
3.28
7.05
3.40
6.76
3.03
9.22
2.71
8.97
2.81
8.40
3.05
8.15
3.17
7.75
3.36
7.50
3.49
7.15
3.03
9.25
2.72
9.00
2.82
8.43
3.06
8.18
3.18
7.77
3.38
7.53
3.50
7.17
3.03
9.46
2.84
9.21
2.94
8.62
3.19
8.37
3.31
7.95
3.52
7.70
3.60
7.34
3.03
9.47
2.84
9.22
2.94
8.63
3.19
8.38
3.31
7.96
3.52
7.71
3.60
7.34
3.03
9.49
2.84
9.24
2.94
8.65
3.19
8.40
3.31
7.98
3.52
7.72
3.60
7.35
3.03
9.51
2.85
9.26
2.95
8.67
3.20
8.42
3.32
7.99
3.53
7.74
3.60
7.37
3.03

Indoor air temp.:CWB


18C
19C
TC
PI
TC
PI
kW
kW
kW
kW
8.80
2.59
8.98
2.61
8.57
2.68
8.76
2.70
8.05
2.90
8.23
2.93
7.83
3.01
8.01
3.03
7.45
3.20
7.64
3.22
7.23
3.31
7.41
3.34
6.92
3.03
7.08
3.03
9.38
3.04
9.57
3.07
9.14
3.14
9.34
3.17
8.58
3.41
8.78
3.44
8.34
3.54
8.54
3.56
7.95
3.75
8.14
3.75
7.71
3.60
7.90
3.60
7.43
3.03
7.59
3.03
9.04
2.70
9.23
2.72
8.81
2.79
9.00
2.82
8.27
3.03
8.46
3.05
8.04
3.14
8.23
3.16
7.66
3.33
7.85
3.36
7.43
3.46
7.62
3.48
7.09
3.03
7.25
3.03
9.62
2.77
9.82
2.79
9.37
2.86
9.58
2.89
8.80
3.10
9.00
3.13
8.56
3.22
8.76
3.24
8.15
3.42
8.35
3.44
7.91
3.54
8.11
3.57
7.49
3.03
7.66
3.03
9.65
2.77
9.85
2.80
9.41
2.87
9.61
2.90
8.83
3.11
9.04
3.14
8.59
3.23
8.79
3.25
8.18
3.43
8.38
3.45
7.93
3.55
8.14
3.58
7.51
3.03
7.68
3.03
9.87
2.89 10.08 2.92
9.62
2.99
9.83
3.02
9.03
3.25
9.24
3.28
8.78
3.37
8.99
3.39
8.36
3.57
8.57
3.60
8.11
3.60
8.31
3.60
7.68
3.03
7.84
3.03
9.88
2.89 10.09 2.92
9.63
2.99
9.84
3.02
9.04
3.25
9.25
3.28
8.79
3.37
9.00
3.39
8.37
3.57
8.58
3.60
8.12
3.60
8.32
3.60
7.68
3.03
7.85
3.03
9.90
2.89 10.11 2.92
9.65
2.99
9.86
3.02
9.06
3.25
9.27
3.28
8.81
3.37
9.02
3.39
8.39
3.57
8.60
3.60
8.14
3.60
8.34
3.60
7.70
3.03
7.87
3.03
9.93
2.90 10.13 2.93
9.67
3.00
9.88
3.03
9.08
3.26
9.29
3.29
8.83
3.38
9.04
3.40
8.41
3.59
8.62
3.61
8.15
3.60
8.35
3.60
7.71
3.03
7.88
3.03

22C
TC
PI
kW
kW
9.53
2.68
9.31
2.77
8.79
3.00
8.56
3.11
8.19
3.29
7.97
3.41
7.56
3.03
10.16 3.15
9.93
3.26
9.37
3.53
9.13
3.65
8.73
3.75
8.49
3.60
8.06
3.03
9.80
2.80
9.57
2.89
9.03
3.13
8.80
3.24
8.42
3.43
8.19
3.56
7.73
3.03
10.43 2.87
10.18 2.97
9.61
3.21
9.37
3.32
8.96
3.52
8.70
3.60
8.15
3.03
10.46 2.88
10.22 2.97
9.64
3.22
9.40
3.33
8.99
3.53
8.73
3.60
8.17
3.03
10.70 3.00
10.45 3.10
9.86
3.36
9.61
3.47
9.19
3.68
8.90
3.60
8.34
3.03
10.71 3.00
10.46 3.10
9.87
3.36
9.62
3.47
9.20
3.68
8.91
3.60
8.35
3.03
10.74 3.00
10.48 3.10
9.90
3.36
9.64
3.47
9.22
3.68
8.93
3.60
8.36
3.03
10.76 3.01
10.51 3.11
9.92
3.37
9.66
3.49
9.24
3.69
8.95
3.60
8.38
3.03

24C
TC
PI
kW
kW
9.90
2.73
9.68
2.82
9.16
3.05
8.93
3.15
8.56
3.34
8.34
3.46
7.87
3.03
10.56 3.21
10.32 3.32
9.76
3.58
9.52
3.71
9.11
3.75
8.87
3.60
8.37
3.03
10.17 2.85
9.94
2.94
9.41
3.18
9.18
3.29
8.79
3.48
8.56
3.60
8.04
3.03
10.83 2.92
10.58 3.02
10.01 3.26
9.77
3.37
9.36
3.57
9.08
3.60
8.47
3.03
10.87 2.93
10.62 3.03
10.05 3.27
9.80
3.38
9.39
3.58
9.11
3.60
8.50
3.03
11.11 3.06
10.86 3.16
10.28 3.41
10.03 3.53
9.61
3.74
9.28
3.60
8.66
3.03
11.13 3.06
10.87 3.16
10.29 3.41
10.04 3.53
9.62
3.74
9.29
3.60
8.67
3.03
11.15 3.06
10.90 3.16
10.31 3.41
10.06 3.53
9.64
3.74
9.31
3.60
8.68
3.03
11.18 3.07
10.92 3.17
10.33 3.42
10.08 3.54
9.66
3.75
9.33
3.60
8.70
3.03

119

Capacity Tables

Combination
(Capacity)
2.0+2.0+2.0

2.0+2.0+2.5

2.0+2.0+3.5

2.0+2.0+5.0

2.0+2.0+6.0

2.0+2.0+7.1

2.0+2.5+2.5

2.0+2.5+3.5

2.0+2.5+5.0

120

EDAU12-722

Outdoor
air temp.
CDB
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0

14C
TC
PI
kW
kW
6.67
1.72
6.48
1.78
6.05
1.94
5.87
2.01
5.56
2.14
5.37
2.22
5.19
2.30
6.99
1.90
6.80
1.97
6.34
2.14
6.15
2.22
5.83
2.36
5.63
2.45
5.44
2.55
7.65
2.24
7.44
2.32
6.95
2.52
6.73
2.61
6.38
2.78
6.17
2.89
5.95
3.00
8.45
2.44
8.21
2.53
7.67
2.75
7.43
2.85
7.04
3.04
6.81
3.15
6.53
3.03
8.87
2.67
8.63
2.77
8.05
3.01
7.80
3.12
7.39
3.32
7.15
3.45
6.84
3.03
9.08
2.79
8.83
2.89
8.24
3.15
7.99
3.27
7.57
3.48
7.32
3.60
7.02
3.03
7.34
2.09
7.14
2.16
6.66
2.35
6.46
2.44
6.12
2.60
5.92
2.70
5.71
2.80
7.95
2.44
7.73
2.53
7.21
2.75
6.99
2.85
6.62
3.04
6.40
3.15
6.16
3.03
8.67
2.56
8.43
2.65
7.87
2.88
7.63
2.99
7.23
3.18
6.98
3.30
6.68
3.03

16C
TC
PI
kW
kW
6.97
1.75
6.79
1.81
6.36
1.97
6.17
2.04
5.86
2.17
5.68
2.25
5.49
2.34
7.31
1.94
7.12
2.00
6.66
2.18
6.47
2.26
6.15
2.40
5.95
2.49
5.76
2.58
8.01
2.28
7.79
2.36
7.30
2.56
7.08
2.66
6.73
2.82
6.52
2.93
6.30
3.03
8.84
2.49
8.60
2.58
8.05
2.80
7.82
2.90
7.43
3.08
7.19
3.20
6.88
3.03
9.28
2.72
9.03
2.82
8.46
3.06
8.21
3.18
7.80
3.38
7.55
3.50
7.19
3.03
9.50
2.85
9.25
2.95
8.66
3.20
8.41
3.32
7.99
3.53
7.73
3.60
7.36
3.03
7.68
2.13
7.48
2.20
7.00
2.39
6.80
2.48
6.46
2.64
6.25
2.74
6.05
2.84
8.31
2.49
8.09
2.58
7.57
2.80
7.35
2.90
6.99
3.08
6.77
3.20
6.50
3.03
9.07
2.61
8.83
2.70
8.27
2.93
8.02
3.04
7.62
3.23
7.38
3.35
7.04
3.03

Indoor air temp.:CWB


18C
19C
TC
PI
TC
PI
kW
kW
kW
kW
7.28
1.78
7.43
1.80
7.09
1.85
7.25
1.86
6.66
2.00
6.82
2.02
6.48
2.08
6.63
2.09
6.17
2.20
6.32
2.22
5.98
2.29
6.14
2.30
5.80
2.37
5.95
2.39
7.63
1.97
7.79
1.99
7.44
2.04
7.60
2.06
6.98
2.21
7.14
2.23
6.79
2.29
6.95
2.31
6.47
2.44
6.63
2.45
6.27
2.53
6.43
2.54
6.08
2.62
6.24
2.64
8.36
2.32
8.53
2.34
8.14
2.40
8.32
2.42
7.65
2.61
7.82
2.63
7.43
2.70
7.61
2.72
7.08
2.87
7.26
2.89
6.87
2.97
7.04
3.00
6.64
3.03
6.80
3.03
9.22
2.54
9.42
2.56
8.99
2.62
9.18
2.65
8.44
2.85
8.63
2.87
8.21
2.95
8.40
2.97
7.82
3.13
8.01
3.16
7.58
3.25
7.77
3.27
7.22
3.03
7.39
3.03
9.68
2.77
9.89
2.80
9.44
2.87
9.64
2.90
8.86
3.11
9.07
3.14
8.62
3.23
8.82
3.25
8.21
3.43
8.41
3.45
7.96
3.55
8.16
3.58
7.53
3.03
7.70
3.03
9.92
2.90 10.12 2.93
9.66
3.00
9.87
3.03
9.07
3.26
9.28
3.29
8.82
3.38
9.03
3.40
8.40
3.59
8.61
3.61
8.14
3.60
8.35
3.60
7.71
3.03
7.87
3.03
8.02
2.17
8.18
2.19
7.81
2.24
7.98
2.26
7.34
2.43
7.50
2.45
7.13
2.52
7.30
2.54
6.79
2.68
6.96
2.70
6.59
2.78
6.76
2.80
6.38
2.88
6.55
2.90
8.67
2.54
8.86
2.56
8.45
2.62
8.64
2.65
7.94
2.85
8.12
2.87
7.72
2.95
7.90
2.97
7.35
3.13
7.53
3.16
7.13
3.25
7.31
3.27
6.83
3.03
6.99
3.03
9.47
2.66
9.66
2.68
9.22
2.75
9.42
2.77
8.66
2.98
8.86
3.01
8.42
3.09
8.62
3.11
8.02
3.28
8.22
3.30
7.78
3.40
7.98
3.43
7.38
3.03
7.55
3.03

22C
TC
PI
kW
kW
7.89
1.85
7.71
1.91
7.27
2.07
7.09
2.14
6.78
2.27
6.59
2.35
6.41
2.44
8.27
2.05
8.08
2.11
7.62
2.29
7.43
2.37
7.11
2.51
6.91
2.60
6.72
2.69
9.06
2.41
8.84
2.49
8.35
2.69
8.14
2.79
7.78
2.96
7.57
3.06
7.29
3.03
10.00 2.63
9.76
2.72
9.22
2.94
8.98
3.04
8.59
3.23
8.35
3.34
7.89
3.03
10.50 2.88
10.25 2.97
9.68
3.22
9.43
3.33
9.02
3.53
8.76
3.60
8.20
3.03
10.75 3.01
10.49 3.11
9.91
3.37
9.65
3.49
9.23
3.69
8.94
3.60
8.37
3.03
8.69
2.25
8.48
2.32
8.01
2.52
7.80
2.60
7.46
2.76
7.26
2.86
7.06
2.96
9.40
2.63
9.18
2.72
8.67
2.94
8.45
3.04
8.08
3.23
7.86
3.34
7.47
3.03
10.26 2.75
10.02 2.85
9.46
3.08
9.22
3.19
8.81
3.38
8.57
3.50
8.05
3.03

24C
TC
PI
kW
kW
8.20
1.88
8.01
1.95
7.58
2.10
7.39
2.18
7.08
2.30
6.90
2.39
6.71
2.47
8.59
2.08
8.40
2.15
7.94
2.32
7.75
2.40
7.43
2.55
7.23
2.64
7.04
2.73
9.41
2.45
9.20
2.53
8.70
2.74
8.49
2.83
8.13
3.00
7.92
3.10
7.60
3.03
10.38 2.68
10.15 2.77
9.60
2.99
9.37
3.09
8.98
3.27
8.74
3.39
8.22
3.03
10.90 2.93
10.66 3.03
10.08 3.27
9.84
3.38
9.43
3.58
9.14
3.60
8.52
3.03
11.16 3.07
10.91 3.17
10.32 3.42
10.07 3.54
9.65
3.75
9.32
3.60
8.69
3.03
9.02
2.29
8.82
2.37
8.34
2.56
8.14
2.64
7.80
2.80
7.60
2.90
7.39
3.00
9.77
2.68
9.55
2.77
9.03
2.99
8.81
3.09
8.44
3.27
8.22
3.39
7.78
3.03
10.66 2.80
10.42 2.90
9.85
3.13
9.61
3.24
9.21
3.43
8.97
3.55
8.37
3.03

SUPER MULTI NX E-Series Heat Pump

EDAU12-722

Combination
(Capacity)
2.0+2.5+6.0

2.0+2.5+7.1

2.0+3.5+3.5

2.0+3.5+5.0

2.0+3.5+6.0

2.0+3.5+7.1

2.0+5.0+5.0

2.0+5.0+6.0

2.0+5.0+7.1

Capacity Tables

Outdoor
air temp.
CDB
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0

SUPER MULTI NX E-Series Heat Pump

14C
TC
PI
kW
kW
8.89
2.67
8.65
2.77
8.07
3.01
7.82
3.12
7.41
3.32
7.16
3.45
6.85
3.03
9.08
2.79
8.83
2.89
8.24
3.15
7.99
3.27
7.57
3.48
7.32
3.60
7.02
3.03
8.28
2.60
8.05
2.69
7.51
2.93
7.28
3.04
6.90
3.23
6.67
3.35
6.42
3.03
8.86
2.67
8.62
2.77
8.04
3.01
7.80
3.12
7.39
3.32
7.14
3.45
6.83
3.03
9.07
2.79
8.82
2.89
8.23
3.14
7.98
3.26
7.56
3.47
7.31
3.60
7.01
3.03
9.12
2.79
8.87
2.89
8.28
3.15
8.03
3.27
7.60
3.48
7.35
3.60
7.04
3.03
9.45
2.74
9.18
2.83
8.57
3.08
8.31
3.20
7.87
3.40
7.61
3.53
7.23
3.03
9.60
2.86
9.33
2.96
8.71
3.22
8.44
3.34
8.00
3.56
7.73
3.60
7.36
3.03
9.66
2.87
9.39
2.97
8.76
3.23
8.49
3.35
8.05
3.57
7.78
3.60
7.40
3.03

16C
TC
PI
kW
kW
9.30
2.72
9.05
2.82
8.48
3.06
8.23
3.18
7.82
3.38
7.57
3.50
7.20
3.03
9.50
2.85
9.25
2.95
8.66
3.20
8.41
3.32
7.99
3.53
7.73
3.60
7.36
3.03
8.66
2.65
8.43
2.74
7.89
2.98
7.66
3.09
7.28
3.28
7.05
3.40
6.76
3.03
9.27
2.72
9.02
2.82
8.45
3.06
8.20
3.18
7.79
3.38
7.54
3.50
7.18
3.03
9.49
2.84
9.24
2.94
8.65
3.19
8.40
3.31
7.98
3.52
7.72
3.60
7.35
3.03
9.54
2.85
9.29
2.95
8.70
3.20
8.44
3.32
8.02
3.53
7.77
3.60
7.39
3.03
9.88
2.79
9.62
2.89
9.00
3.14
8.74
3.25
8.30
3.46
8.04
3.59
7.59
3.03
10.04 2.92
9.77
3.02
9.15
3.28
8.88
3.40
8.44
3.61
8.17
3.60
7.72
3.03
10.10 2.92
9.83
3.03
9.20
3.29
8.94
3.41
8.49
3.62
8.22
3.60
7.76
3.03

Indoor air temp.:CWB


18C
19C
TC
PI
TC
PI
kW
kW
kW
kW
9.71
2.77
9.91
2.80
9.46
2.87
9.66
2.90
8.88
3.11
9.09
3.14
8.64
3.23
8.84
3.25
8.22
3.43
8.43
3.45
7.98
3.55
8.18
3.58
7.55
3.03
7.72
3.03
9.92
2.90 10.12 2.93
9.66
3.00
9.87
3.03
9.07
3.26
9.28
3.29
8.82
3.38
9.03
3.40
8.40
3.59
8.61
3.61
8.14
3.60
8.35
3.60
7.71
3.03
7.87
3.03
9.04
2.70
9.23
2.72
8.81
2.79
9.00
2.82
8.27
3.03
8.46
3.05
8.04
3.14
8.23
3.16
7.66
3.33
7.85
3.36
7.43
3.46
7.62
3.48
7.09
3.03
7.25
3.03
9.67
2.77
9.88
2.80
9.43
2.87
9.63
2.90
8.85
3.11
9.06
3.14
8.61
3.23
8.81
3.25
8.20
3.43
8.40
3.45
7.95
3.55
8.15
3.58
7.53
3.03
7.69
3.03
9.90
2.89 10.11 2.92
9.65
2.99
9.86
3.02
9.06
3.25
9.27
3.28
8.81
3.37
9.02
3.39
8.39
3.57
8.60
3.60
8.14
3.60
8.34
3.60
7.70
3.03
7.87
3.03
9.96
2.90 10.17 2.93
9.71
3.00
9.91
3.03
9.11
3.26
9.32
3.29
8.86
3.38
9.07
3.40
8.44
3.59
8.65
3.61
8.18
3.60
8.38
3.60
7.73
3.03
7.90
3.03
10.31 2.84 10.53 2.87
10.05 2.94 10.26 2.97
9.44
3.19
9.65
3.22
9.17
3.31
9.39
3.33
8.74
3.51
8.95
3.54
8.47
3.60
8.67
3.60
7.95
3.03
8.12
3.03
10.48 2.97 10.69 3.00
10.21 3.07 10.43 3.10
9.59
3.33
9.81
3.36
9.32
3.46
9.54
3.48
8.88
3.67
9.10
3.70
8.59
3.60
8.79
3.60
8.07
3.03
8.24
3.03
10.54 2.98 10.76 3.01
10.27 3.08 10.49 3.11
9.65
3.34
9.87
3.37
9.38
3.47
9.60
3.49
8.93
3.68
9.15
3.71
8.64
3.60
8.85
3.60
8.11
3.03
8.29
3.03

22C
TC
PI
kW
kW
10.52 2.88
10.27 2.97
9.70
3.22
9.45
3.33
9.04
3.53
8.78
3.60
8.21
3.03
10.75 3.01
10.49 3.11
9.91
3.37
9.65
3.49
9.23
3.69
8.94
3.60
8.37
3.03
9.80
2.80
9.57
2.89
9.03
3.13
8.80
3.24
8.42
3.43
8.19
3.56
7.73
3.03
10.49 2.88
10.24 2.97
9.66
3.22
9.42
3.33
9.01
3.53
8.75
3.60
8.19
3.03
10.74 3.00
10.48 3.10
9.90
3.36
9.64
3.47
9.22
3.68
8.93
3.60
8.36
3.03
10.79 3.01
10.54 3.11
9.95
3.37
9.70
3.49
9.27
3.69
8.97
3.60
8.40
3.03
11.18 2.95
10.91 3.05
10.30 3.30
10.04 3.41
9.60
3.62
9.29
3.60
8.63
3.03
11.35 3.08
11.09 3.19
10.47 3.45
10.20 3.57
9.75
3.75
9.40
3.60
8.75
3.03
11.43 3.09
11.16 3.19
10.53 3.46
10.26 3.58
9.80
3.75
9.46
3.60
8.80
3.03

24C
TC
PI
kW
kW
10.93 2.93
10.68 3.03
10.11 3.27
9.86
3.38
9.45
3.58
9.16
3.60
8.54
3.03
11.16 3.07
10.91 3.17
10.32 3.42
10.07 3.54
9.65
3.75
9.32
3.60
8.69
3.03
10.17 2.85
9.94
2.94
9.41
3.18
9.18
3.29
8.79
3.48
8.56
3.60
8.04
3.03
10.89 2.93
10.65 3.03
10.07 3.27
9.82
3.38
9.41
3.58
9.13
3.60
8.51
3.03
11.15 3.06
10.90 3.16
10.31 3.41
10.06 3.53
9.64
3.74
9.31
3.60
8.68
3.03
11.21 3.07
10.96 3.17
10.37 3.42
10.11 3.54
9.69
3.75
9.36
3.60
8.72
3.03
11.61 3.00
11.35 3.10
10.73 3.35
10.47 3.47
10.03 3.67
9.69
3.60
8.97
3.03
11.79 3.14
11.53 3.24
10.91 3.50
10.64 3.62
10.16 3.75
9.80
3.60
9.09
3.03
11.87 3.15
11.60 3.25
10.97 3.51
10.71 3.63
10.22 3.75
9.85
3.60
9.13
3.03

121

Capacity Tables

Combination
(Capacity)
2.0+6.0+6.0

2.5+2.5+2.5

2.5+2.5+3.5

2.5+2.5+5.0

2.5+2.5+6.0

2.5+2.5+7.1

2.5+3.5+3.5

2.5+3.5+5.0

2.5+3.5+6.0

122

EDAU12-722

Outdoor
air temp.
CDB
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0

14C
TC
PI
kW
kW
9.66
2.87
9.39
2.97
8.76
3.23
8.49
3.35
8.05
3.57
7.78
3.60
7.40
3.03
7.65
2.24
7.44
2.32
6.95
2.52
6.73
2.61
6.38
2.78
6.17
2.89
5.95
3.00
8.10
2.49
7.87
2.58
7.35
2.81
7.12
2.91
6.75
3.10
6.52
3.22
6.28
3.03
8.85
2.66
8.61
2.76
8.03
3.00
7.79
3.11
7.38
3.31
7.13
3.44
6.82
3.03
8.89
2.67
8.65
2.77
8.07
3.01
7.82
3.12
7.41
3.32
7.16
3.45
6.85
3.03
9.08
2.79
8.83
2.89
8.24
3.15
7.99
3.27
7.57
3.48
7.32
3.60
7.02
3.03
8.39
2.54
8.16
2.63
7.61
2.86
7.38
2.97
6.99
3.16
6.76
3.28
6.49
3.03
8.86
2.67
8.62
2.77
8.04
3.01
7.80
3.12
7.39
3.32
7.14
3.45
6.83
3.03
9.07
2.79
8.82
2.89
8.23
3.14
7.98
3.26
7.56
3.47
7.31
3.60
7.01
3.03

16C
TC
PI
kW
kW
10.10 2.92
9.83
3.03
9.20
3.29
8.94
3.41
8.49
3.62
8.22
3.60
7.76
3.03
8.01
2.28
7.79
2.36
7.30
2.56
7.08
2.66
6.73
2.82
6.52
2.93
6.30
3.03
8.47
2.54
8.24
2.63
7.72
2.86
7.49
2.96
7.12
3.15
6.89
3.26
6.61
3.03
9.26
2.71
9.01
2.81
8.44
3.05
8.19
3.17
7.78
3.36
7.54
3.49
7.17
3.03
9.30
2.72
9.05
2.82
8.48
3.06
8.23
3.18
7.82
3.38
7.57
3.50
7.20
3.03
9.50
2.85
9.25
2.95
8.66
3.20
8.41
3.32
7.99
3.53
7.73
3.60
7.36
3.03
8.77
2.59
8.54
2.68
8.00
2.91
7.76
3.02
7.38
3.21
7.14
3.33
6.83
3.03
9.27
2.72
9.02
2.82
8.45
3.06
8.20
3.18
7.79
3.38
7.54
3.50
7.18
3.03
9.49
2.84
9.24
2.94
8.65
3.19
8.40
3.31
7.98
3.52
7.72
3.60
7.35
3.03

Indoor air temp.:CWB


18C
19C
TC
PI
TC
PI
kW
kW
kW
kW
10.54 2.98 10.76 3.01
10.27 3.08 10.49 3.11
9.65
3.34
9.87
3.37
9.38
3.47
9.60
3.49
8.93
3.68
9.15
3.71
8.64
3.60
8.85
3.60
8.11
3.03
8.29
3.03
8.36
2.32
8.53
2.34
8.14
2.40
8.32
2.42
7.65
2.61
7.82
2.63
7.43
2.70
7.61
2.72
7.08
2.87
7.26
2.89
6.87
2.97
7.04
3.00
6.64
3.03
6.80
3.03
8.84
2.59
9.02
2.61
8.61
2.68
8.80
2.70
8.09
2.90
8.27
2.93
7.86
3.01
8.05
3.03
7.49
3.20
7.68
3.22
7.26
3.31
7.45
3.34
6.95
3.03
7.11
3.03
9.66
2.77
9.87
2.79
9.42
2.86
9.62
2.89
8.84
3.10
9.05
3.13
8.60
3.22
8.80
3.24
8.19
3.42
8.39
3.44
7.94
3.54
8.14
3.57
7.52
3.03
7.69
3.03
9.71
2.77
9.91
2.80
9.46
2.87
9.66
2.90
8.88
3.11
9.09
3.14
8.64
3.23
8.84
3.25
8.22
3.43
8.43
3.45
7.98
3.55
8.18
3.58
7.55
3.03
7.72
3.03
9.92
2.90 10.12 2.93
9.66
3.00
9.87
3.03
9.07
3.26
9.28
3.29
8.82
3.38
9.03
3.40
8.40
3.59
8.61
3.61
8.14
3.60
8.35
3.60
7.71
3.03
7.87
3.03
9.16
2.64
9.35
2.66
8.92
2.73
9.12
2.75
8.38
2.96
8.57
2.99
8.15
3.07
8.34
3.09
7.76
3.26
7.95
3.28
7.53
3.38
7.72
3.40
7.17
3.03
7.33
3.03
9.67
2.77
9.88
2.80
9.43
2.87
9.63
2.90
8.85
3.11
9.06
3.14
8.61
3.23
8.81
3.25
8.20
3.43
8.40
3.45
7.95
3.55
8.15
3.58
7.53
3.03
7.69
3.03
9.90
2.89 10.11 2.92
9.65
2.99
9.86
3.02
9.06
3.25
9.27
3.28
8.81
3.37
9.02
3.39
8.39
3.57
8.60
3.60
8.14
3.60
8.34
3.60
7.70
3.03
7.87
3.03

22C
TC
PI
kW
kW
11.43 3.09
11.16 3.19
10.53 3.46
10.26 3.58
9.80
3.75
9.46
3.60
8.80
3.03
9.06
2.41
8.84
2.49
8.35
2.69
8.14
2.79
7.78
2.96
7.57
3.06
7.29
3.03
9.58
2.68
9.36
2.77
8.83
3.00
8.61
3.11
8.23
3.29
8.01
3.41
7.59
3.03
10.47 2.87
10.23 2.97
9.65
3.21
9.41
3.32
9.00
3.52
8.74
3.60
8.18
3.03
10.52 2.88
10.27 2.97
9.70
3.22
9.45
3.33
9.04
3.53
8.78
3.60
8.21
3.03
10.75 3.01
10.49 3.11
9.91
3.37
9.65
3.49
9.23
3.69
8.94
3.60
8.37
3.03
9.93
2.74
9.69
2.83
9.15
3.06
8.92
3.17
8.53
3.36
8.30
3.48
7.82
3.03
10.49 2.88
10.24 2.97
9.66
3.22
9.42
3.33
9.01
3.53
8.75
3.60
8.19
3.03
10.74 3.00
10.48 3.10
9.90
3.36
9.64
3.47
9.22
3.68
8.93
3.60
8.36
3.03

24C
TC
PI
kW
kW
11.87 3.15
11.60 3.25
10.97 3.51
10.71 3.63
10.22 3.75
9.85
3.60
9.13
3.03
9.41
2.45
9.20
2.53
8.70
2.74
8.49
2.83
8.13
3.00
7.92
3.10
7.60
3.03
9.95
2.73
9.73
2.82
9.20
3.05
8.98
3.15
8.60
3.34
8.38
3.46
7.90
3.03
10.88 2.92
10.63 3.02
10.06 3.26
9.81
3.37
9.40
3.57
9.12
3.60
8.50
3.03
10.93 2.93
10.68 3.03
10.11 3.27
9.86
3.38
9.45
3.58
9.16
3.60
8.54
3.03
11.16 3.07
10.91 3.17
10.32 3.42
10.07 3.54
9.65
3.75
9.32
3.60
8.69
3.03
10.31 2.79
10.08 2.88
9.53
3.11
9.30
3.22
8.91
3.41
8.68
3.53
8.14
3.03
10.89 2.93
10.65 3.03
10.07 3.27
9.82
3.38
9.41
3.58
9.13
3.60
8.51
3.03
11.15 3.06
10.90 3.16
10.31 3.41
10.06 3.53
9.64
3.74
9.31
3.60
8.68
3.03

SUPER MULTI NX E-Series Heat Pump

EDAU12-722

Combination
(Capacity)
2.5+3.5+7.1

2.5+5.0+5.0

2.5+5.0+6.0

2.5+6.0+6.0

3.5+3.5+3.5

3.5+3.5+5.0

3.5+3.5+6.0

3.5+3.5+7.1

3.5+5.0+5.0

Capacity Tables

Outdoor
air temp.
CDB
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0

SUPER MULTI NX E-Series Heat Pump

14C
TC
PI
kW
kW
9.12
2.79
8.87
2.89
8.28
3.15
8.03
3.27
7.60
3.48
7.35
3.60
7.04
3.03
9.53
2.79
9.26
2.89
8.64
3.15
8.38
3.27
7.94
3.48
7.67
3.60
7.29
3.03
9.64
2.86
9.37
2.96
8.74
3.22
8.48
3.34
8.03
3.56
7.76
3.60
7.38
3.03
9.66
2.87
9.39
2.97
8.76
3.23
8.49
3.35
8.05
3.57
7.78
3.60
7.40
3.03
8.63
2.60
8.39
2.69
7.83
2.93
7.59
3.04
7.19
3.23
6.95
3.35
6.66
3.03
9.04
2.79
8.79
2.89
8.21
3.14
7.95
3.26
7.54
3.47
7.28
3.60
6.99
3.03
9.12
2.79
8.87
2.89
8.28
3.14
8.03
3.26
7.60
3.47
7.35
3.60
7.04
3.03
9.10
2.79
8.85
2.89
8.26
3.15
8.01
3.27
7.59
3.48
7.33
3.60
7.03
3.03
9.64
2.86
9.37
2.96
8.74
3.22
8.48
3.34
8.03
3.56
7.76
3.60
7.38
3.03

16C
TC
PI
kW
kW
9.54
2.85
9.29
2.95
8.70
3.20
8.44
3.32
8.02
3.53
7.77
3.60
7.39
3.03
9.96
2.85
9.70
2.95
9.08
3.20
8.82
3.32
8.37
3.53
8.11
3.60
7.66
3.03
10.08 2.92
9.81
3.02
9.19
3.28
8.92
3.40
8.47
3.61
8.20
3.60
7.74
3.03
10.10 2.92
9.83
3.03
9.20
3.29
8.94
3.41
8.49
3.62
8.22
3.60
7.76
3.03
9.03
2.65
8.79
2.74
8.23
2.98
7.99
3.09
7.59
3.28
7.35
3.40
7.01
3.03
9.46
2.84
9.21
2.94
8.62
3.19
8.37
3.31
7.95
3.52
7.70
3.60
7.34
3.03
9.54
2.84
9.29
2.94
8.70
3.19
8.44
3.31
8.02
3.52
7.77
3.60
7.39
3.03
9.52
2.85
9.27
2.95
8.68
3.20
8.42
3.32
8.00
3.53
7.75
3.60
7.38
3.03
10.08 2.92
9.81
3.02
9.19
3.28
8.92
3.40
8.47
3.61
8.20
3.60
7.74
3.03

Indoor air temp.:CWB


18C
19C
TC
PI
TC
PI
kW
kW
kW
kW
9.96
2.90 10.17 2.93
9.71
3.00
9.91
3.03
9.11
3.26
9.32
3.29
8.86
3.38
9.07
3.40
8.44
3.59
8.65
3.61
8.18
3.60
8.38
3.60
7.73
3.03
7.90
3.03
10.40 2.90 10.62 2.93
10.13 3.00 10.35 3.03
9.52
3.26
9.73
3.29
9.25
3.38
9.47
3.40
8.81
3.59
9.03
3.61
8.53
3.60
8.74
3.60
8.01
3.03
8.18
3.03
10.52 2.97 10.74 3.00
10.25 3.07 10.47 3.10
9.63
3.33
9.85
3.36
9.36
3.46
9.58
3.48
8.91
3.67
9.13
3.70
8.62
3.60
8.83
3.60
8.10
3.03
8.27
3.03
10.54 2.98 10.76 3.01
10.27 3.08 10.49 3.11
9.65
3.34
9.87
3.37
9.38
3.47
9.60
3.49
8.93
3.68
9.15
3.71
8.64
3.60
8.85
3.60
8.11
3.03
8.29
3.03
9.42
2.70
9.62
2.72
9.18
2.79
9.38
2.82
8.62
3.03
8.82
3.05
8.38
3.14
8.58
3.16
7.98
3.33
8.18
3.36
7.74
3.46
7.94
3.48
7.35
3.03
7.52
3.03
9.87
2.89 10.08 2.92
9.62
2.99
9.83
3.02
9.03
3.25
9.24
3.28
8.78
3.37
8.99
3.39
8.36
3.57
8.57
3.60
8.11
3.60
8.31
3.60
7.68
3.03
7.84
3.03
9.96
2.89 10.17 2.92
9.71
2.99
9.91
3.02
9.11
3.25
9.32
3.28
8.86
3.37
9.07
3.39
8.44
3.57
8.65
3.60
8.18
3.60
8.38
3.60
7.73
3.03
7.90
3.03
9.94
2.90 10.15 2.93
9.68
3.00
9.89
3.03
9.09
3.26
9.30
3.29
8.84
3.38
9.05
3.40
8.42
3.59
8.63
3.61
8.16
3.60
8.36
3.60
7.72
3.03
7.89
3.03
10.52 2.97 10.74 3.00
10.25 3.07 10.47 3.10
9.63
3.33
9.85
3.36
9.36
3.46
9.58
3.48
8.91
3.67
9.13
3.70
8.62
3.60
8.83
3.60
8.10
3.03
8.27
3.03

22C
TC
PI
kW
kW
10.79 3.01
10.54 3.11
9.95
3.37
9.70
3.49
9.27
3.69
8.97
3.60
8.40
3.03
11.27 3.01
11.01 3.11
10.39 3.37
10.12 3.49
9.68
3.69
9.35
3.60
8.70
3.03
11.40 3.08
11.13 3.19
10.51 3.45
10.24 3.57
9.79
3.75
9.44
3.60
8.78
3.03
11.43 3.09
11.16 3.19
10.53 3.46
10.26 3.58
9.80
3.75
9.46
3.60
8.80
3.03
10.21 2.80
9.97
2.89
9.41
3.13
9.17
3.24
8.77
3.43
8.53
3.56
8.01
3.03
10.70 3.00
10.45 3.10
9.86
3.36
9.61
3.47
9.19
3.68
8.90
3.60
8.34
3.03
10.79 3.00
10.54 3.10
9.95
3.36
9.70
3.47
9.27
3.68
8.97
3.60
8.40
3.03
10.77 3.01
10.52 3.11
9.93
3.37
9.68
3.49
9.25
3.69
8.96
3.60
8.38
3.03
11.40 3.08
11.13 3.19
10.51 3.45
10.24 3.57
9.79
3.75
9.44
3.60
8.78
3.03

24C
TC
PI
kW
kW
11.21 3.07
10.96 3.17
10.37 3.42
10.11 3.54
9.69
3.75
9.36
3.60
8.72
3.03
11.71 3.07
11.44 3.17
10.83 3.42
10.56 3.54
10.12 3.75
9.75
3.60
9.03
3.03
11.84 3.14
11.58 3.24
10.95 3.50
10.68 3.62
10.20 3.75
9.84
3.60
9.12
3.03
11.87 3.15
11.60 3.25
10.97 3.51
10.71 3.63
10.22 3.75
9.85
3.60
9.13
3.03
10.61 2.85
10.37 2.94
9.81
3.18
9.57
3.29
9.17
3.48
8.93
3.60
8.33
3.03
11.11 3.06
10.86 3.16
10.28 3.41
10.03 3.53
9.61
3.74
9.28
3.60
8.66
3.03
11.21 3.06
10.96 3.16
10.37 3.41
10.11 3.53
9.69
3.74
9.36
3.60
8.72
3.03
11.19 3.07
10.94 3.17
10.35 3.42
10.09 3.54
9.67
3.75
9.34
3.60
8.71
3.03
11.84 3.14
11.58 3.24
10.95 3.50
10.68 3.62
10.20 3.75
9.84
3.60
9.12
3.03

123

Capacity Tables

Combination
(Capacity)
3.5+5.0+6.0

2.0+2.0+2.0+2.0

2.0+2.0+2.0+2.5

2.0+2.0+2.0+3.5

2.0+2.0+2.0+5.0

2.0+2.0+2.0+6.0

2.0+2.0+2.0+7.1

2.0+2.0+2.5+2.5

2.0+2.0+2.5+3.5

124

EDAU12-722

Outdoor
air temp.
CDB
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0

14C
TC
PI
kW
kW
9.66
2.87
9.39
2.97
8.76
3.23
8.49
3.35
8.05
3.57
7.78
3.60
7.40
3.03
7.95
2.02
7.73
2.09
7.21
2.28
6.99
2.36
6.62
2.52
6.40
2.61
6.18
2.71
8.21
2.13
7.98
2.20
7.45
2.40
7.22
2.49
6.84
2.65
6.61
2.75
6.38
2.85
8.67
2.39
8.43
2.48
7.87
2.70
7.63
2.80
7.23
2.98
6.98
3.09
6.69
3.03
9.20
2.56
8.95
2.66
8.35
2.89
8.10
3.00
7.67
3.19
7.41
3.31
7.05
3.03
9.45
2.74
9.18
2.84
8.57
3.09
8.31
3.21
7.87
3.42
7.61
3.55
7.23
3.03
9.61
2.81
9.34
2.91
8.72
3.17
8.45
3.29
8.01
3.50
7.74
3.60
7.35
3.03
8.45
2.28
8.21
2.37
7.67
2.58
7.43
2.67
7.04
2.84
6.81
2.95
6.56
3.03
8.87
2.67
8.63
2.77
8.05
3.01
7.80
3.12
7.39
3.32
7.15
3.45
6.84
3.03

16C
TC
PI
kW
kW
10.10 2.92
9.83
3.03
9.20
3.29
8.94
3.41
8.49
3.62
8.22
3.60
7.76
3.03
8.31
2.06
8.09
2.13
7.57
2.32
7.35
2.40
6.99
2.55
6.77
2.65
6.54
2.75
8.58
2.17
8.36
2.25
7.82
2.44
7.60
2.53
7.22
2.69
6.99
2.79
6.76
2.90
9.07
2.44
8.83
2.52
8.27
2.74
8.02
2.84
7.62
3.02
7.38
3.14
7.06
3.03
9.63
2.61
9.37
2.71
8.77
2.94
8.52
3.05
8.09
3.24
7.84
3.36
7.42
3.03
9.88
2.80
9.62
2.90
9.00
3.15
8.74
3.26
8.30
3.47
8.04
3.60
7.59
3.03
10.05 2.87
9.78
2.97
9.16
3.22
8.89
3.34
8.45
3.55
8.17
3.60
7.71
3.03
8.84
2.33
8.60
2.41
8.05
2.62
7.82
2.72
7.43
2.89
7.19
3.00
6.93
3.03
9.28
2.72
9.03
2.82
8.46
3.06
8.21
3.18
7.80
3.38
7.55
3.50
7.19
3.03

Indoor air temp.:CWB


18C
19C
TC
PI
TC
PI
kW
kW
kW
kW
10.54 2.98 10.76 3.01
10.27 3.08 10.49 3.11
9.65
3.34
9.87
3.37
9.38
3.47
9.60
3.49
8.93
3.68
9.15
3.71
8.64
3.60
8.85
3.60
8.11
3.03
8.29
3.03
8.67
2.10
8.86
2.12
8.45
2.17
8.64
2.19
7.94
2.36
8.12
2.38
7.72
2.44
7.90
2.46
7.35
2.59
7.53
2.61
7.13
2.69
7.31
2.71
6.91
2.79
7.09
2.81
8.96
2.21
9.15
2.23
8.73
2.29
8.92
2.31
8.20
2.48
8.39
2.50
7.97
2.57
8.16
2.59
7.59
2.73
7.78
2.75
7.36
2.83
7.55
2.85
7.14
2.94
7.32
2.96
9.47
2.48
9.66
2.51
9.22
2.57
9.42
2.59
8.66
2.79
8.86
2.81
8.42
2.89
8.62
2.91
8.02
3.07
8.22
3.09
7.78
3.18
7.98
3.21
7.41
3.03
7.59
3.03
10.05 2.66 10.26 2.69
9.79
2.76 10.00 2.78
9.19
2.99
9.41
3.01
8.94
3.10
9.15
3.12
8.51
3.29
8.72
3.31
8.26
3.41
8.47
3.44
7.78
3.03
7.95
3.03
10.31 2.85 10.53 2.88
10.05 2.95 10.26 2.98
9.44
3.20
9.65
3.23
9.17
3.32
9.39
3.34
8.74
3.52
8.95
3.55
8.46
3.60
8.67
3.60
7.95
3.03
8.12
3.03
10.49 2.92 10.71 2.95
10.22 3.02 10.44 3.05
9.60
3.28
9.82
3.30
9.33
3.40
9.55
3.42
8.89
3.61
9.11
3.63
8.60
3.60
8.81
3.60
8.07
3.03
8.24
3.03
9.22
2.37
9.42
2.40
8.99
2.46
9.18
2.48
8.44
2.66
8.63
2.69
8.21
2.76
8.40
2.78
7.82
2.93
8.01
2.95
7.58
3.04
7.77
3.06
7.28
3.03
7.46
3.03
9.68
2.77
9.89
2.80
9.44
2.87
9.64
2.90
8.86
3.11
9.07
3.14
8.62
3.23
8.82
3.25
8.21
3.43
8.41
3.45
7.96
3.55
8.16
3.58
7.53
3.03
7.70
3.03

22C
TC
PI
kW
kW
11.43 3.09
11.16 3.19
10.53 3.46
10.26 3.58
9.80
3.75
9.46
3.60
8.80
3.03
9.40
2.18
9.18
2.25
8.67
2.44
8.45
2.52
8.08
2.67
7.86
2.77
7.64
2.87
9.71
2.29
9.48
2.37
8.95
2.56
8.72
2.65
8.34
2.81
8.12
2.91
7.89
3.02
10.26 2.58
10.02 2.66
9.46
2.88
9.22
2.98
8.81
3.16
8.57
3.27
8.10
3.03
10.89 2.76
10.63 2.86
10.04 3.09
9.78
3.20
9.36
3.39
9.10
3.51
8.47
3.03
11.18 2.96
10.91 3.06
10.30 3.31
10.04 3.42
9.60
3.63
9.29
3.60
8.63
3.03
11.37 3.03
11.10 3.13
10.48 3.39
10.21 3.51
9.77
3.72
9.42
3.60
8.76
3.03
10.00 2.46
9.76
2.54
9.22
2.75
8.98
2.85
8.59
3.02
8.35
3.13
7.98
3.03
10.50 2.88
10.25 2.97
9.68
3.22
9.43
3.33
9.02
3.53
8.76
3.60
8.20
3.03

24C
TC
PI
kW
kW
11.87 3.15
11.60 3.25
10.97 3.51
10.71 3.63
10.22 3.75
9.85
3.60
9.13
3.03
9.77
2.22
9.55
2.29
9.03
2.48
8.81
2.56
8.44
2.71
8.22
2.81
8.00
2.91
10.09 2.34
9.86
2.41
9.33
2.61
9.10
2.70
8.72
2.86
8.49
2.96
8.24
3.03
10.66 2.62
10.42 2.71
9.85
2.93
9.61
3.03
9.21
3.21
8.97
3.32
8.44
3.03
11.31 2.81
11.06 2.91
10.46 3.14
10.20 3.25
9.78
3.44
9.52
3.56
8.81
3.03
11.61 3.01
11.35 3.11
10.73 3.36
10.47 3.48
10.03 3.68
9.68
3.60
8.97
3.03
11.81 3.08
11.54 3.19
10.92 3.44
10.65 3.56
10.20 3.75
9.82
3.60
9.09
3.03
10.38 2.51
10.15 2.59
9.60
2.80
9.37
2.89
8.98
3.06
8.74
3.17
8.31
3.03
10.90 2.93
10.66 3.03
10.08 3.27
9.84
3.38
9.43
3.58
9.14
3.60
8.52
3.03

SUPER MULTI NX E-Series Heat Pump

EDAU12-722

Combination
(Capacity)
2.0+2.0+2.5+5.0

2.0+2.0+2.5+6.0

2.0+2.0+2.5+7.1

2.0+2.0+3.5+3.5

2.0+2.0+3.5+5.0

2.0+2.0+3.5+6.0

2.0+2.0+5.0+5.0

2.0+2.5+2.5+2.5

2.0+2.5+2.5+3.5

Capacity Tables

Outdoor
air temp.
CDB
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0

SUPER MULTI NX E-Series Heat Pump

14C
TC
PI
kW
kW
9.33
2.68
9.08
2.78
8.47
3.02
8.21
3.13
7.78
3.33
7.52
3.46
7.15
3.03
9.53
2.74
9.26
2.84
8.64
3.09
8.38
3.21
7.94
3.42
7.67
3.55
7.28
3.03
9.65
2.88
9.38
2.98
8.75
3.24
8.49
3.36
8.04
3.58
7.77
3.60
7.40
3.03
8.91
2.67
8.66
2.77
8.09
3.01
7.84
3.12
7.43
3.32
7.18
3.45
6.87
3.03
9.53
2.80
9.26
2.90
8.64
3.16
8.38
3.28
7.94
3.49
7.67
3.60
7.30
3.03
9.64
2.87
9.37
2.97
8.74
3.23
8.48
3.35
8.03
3.57
7.76
3.60
7.39
3.03
9.66
2.56
9.39
2.65
8.76
2.88
8.49
2.99
8.05
3.18
7.78
3.30
7.36
3.03
8.67
2.39
8.43
2.48
7.87
2.70
7.63
2.80
7.23
2.98
6.98
3.09
6.69
3.03
8.91
2.67
8.66
2.77
8.09
3.01
7.84
3.12
7.43
3.32
7.18
3.45
6.87
3.03

16C
TC
PI
kW
kW
9.76
2.73
9.50
2.83
8.90
3.07
8.64
3.19
8.21
3.39
7.95
3.51
7.51
3.03
9.96
2.80
9.70
2.90
9.08
3.15
8.82
3.26
8.37
3.47
8.11
3.60
7.65
3.03
10.09 2.93
9.82
3.04
9.20
3.30
8.93
3.42
8.48
3.63
8.21
3.60
7.76
3.03
9.32
2.72
9.07
2.82
8.50
3.06
8.25
3.18
7.84
3.38
7.59
3.50
7.22
3.03
9.96
2.86
9.70
2.96
9.08
3.21
8.82
3.33
8.37
3.54
8.11
3.60
7.66
3.03
10.08 2.92
9.81
3.03
9.19
3.29
8.92
3.41
8.47
3.62
8.20
3.60
7.75
3.03
10.10 2.61
9.83
2.70
9.20
2.93
8.94
3.04
8.49
3.23
8.22
3.35
7.74
3.03
9.07
2.44
8.83
2.52
8.27
2.74
8.02
2.84
7.62
3.02
7.38
3.14
7.06
3.03
9.32
2.72
9.07
2.82
8.50
3.06
8.25
3.18
7.84
3.38
7.59
3.50
7.22
3.03

Indoor air temp.:CWB


18C
19C
TC
PI
TC
PI
kW
kW
kW
kW
10.19 2.78 10.40 2.81
9.93
2.88 10.14 2.91
9.33
3.12
9.54
3.15
9.07
3.24
9.28
3.26
8.63
3.44
8.85
3.46
8.37
3.56
8.59
3.59
7.86
3.03
8.04
3.03
10.40 2.85 10.62 2.88
10.13 2.95 10.35 2.98
9.52
3.20
9.73
3.23
9.25
3.32
9.47
3.34
8.81
3.52
9.03
3.55
8.54
3.60
8.75
3.60
8.00
3.03
8.18
3.03
10.53 2.99 10.75 3.02
10.26 3.09 10.48 3.12
9.64
3.35
9.86
3.38
9.37
3.48
9.59
3.50
8.92
3.69
9.14
3.72
8.63
3.60
8.84
3.60
8.11
3.03
8.28
3.03
9.73
2.77
9.93
2.80
9.48
2.87
9.69
2.90
8.90
3.11
9.11
3.14
8.66
3.23
8.86
3.25
8.24
3.43
8.45
3.45
8.00
3.55
8.20
3.58
7.56
3.03
7.73
3.03
10.40 2.91 10.62 2.94
10.13 3.01 10.35 3.04
9.52
3.27
9.73
3.30
9.25
3.39
9.47
3.41
8.81
3.60
9.03
3.62
8.53
3.60
8.74
3.60
8.01
3.03
8.18
3.03
10.52 2.98 10.74 3.01
10.25 3.08 10.47 3.11
9.63
3.34
9.85
3.37
9.36
3.47
9.58
3.49
8.91
3.68
9.13
3.71
8.62
3.60
8.83
3.60
8.10
3.03
8.27
3.03
10.54 2.66 10.76 2.68
10.27 2.75 10.49 2.77
9.65
2.98
9.87
3.01
9.38
3.09
9.60
3.11
8.93
3.28
9.15
3.30
8.66
3.40
8.88
3.43
8.12
3.03
8.30
3.03
9.47
2.48
9.66
2.51
9.22
2.57
9.42
2.59
8.66
2.79
8.86
2.81
8.42
2.89
8.62
2.91
8.02
3.07
8.22
3.09
7.78
3.18
7.98
3.21
7.41
3.03
7.59
3.03
9.73
2.77
9.93
2.80
9.48
2.87
9.69
2.90
8.90
3.11
9.11
3.14
8.66
3.23
8.86
3.25
8.24
3.43
8.45
3.45
8.00
3.55
8.20
3.58
7.56
3.03
7.73
3.03

22C
TC
PI
kW
kW
11.04 2.89
10.79 2.98
10.18 3.23
9.92
3.34
9.49
3.54
9.20
3.60
8.55
3.03
11.27 2.96
11.01 3.06
10.39 3.31
10.12 3.42
9.68
3.63
9.36
3.60
8.69
3.03
11.41 3.10
11.15 3.20
10.52 3.47
10.25 3.59
9.79
3.75
9.45
3.60
8.79
3.03
10.54 2.88
10.30 2.97
9.72
3.22
9.47
3.33
9.06
3.53
8.80
3.60
8.23
3.03
11.27 3.02
11.01 3.12
10.39 3.38
10.12 3.50
9.68
3.70
9.35
3.60
8.70
3.03
11.40 3.09
11.13 3.19
10.51 3.46
10.24 3.58
9.78
3.75
9.44
3.60
8.78
3.03
11.43 2.75
11.16 2.85
10.53 3.08
10.26 3.19
9.82
3.38
9.55
3.50
8.84
3.03
10.26 2.58
10.02 2.66
9.46
2.88
9.22
2.98
8.81
3.16
8.57
3.27
8.10
3.03
10.54 2.88
10.30 2.97
9.72
3.22
9.47
3.33
9.06
3.53
8.80
3.60
8.23
3.03

24C
TC
PI
kW
kW
11.47 2.94
11.21 3.04
10.61 3.28
10.35 3.39
9.92
3.59
9.60
3.60
8.89
3.03
11.71 3.01
11.44 3.11
10.83 3.36
10.56 3.48
10.12 3.68
9.76
3.60
9.03
3.03
11.86 3.16
11.59 3.26
10.96 3.52
10.69 3.64
10.21 3.75
9.84
3.60
9.13
3.03
10.95 2.93
10.71 3.03
10.13 3.27
9.88
3.38
9.47
3.58
9.18
3.60
8.55
3.03
11.71 3.08
11.44 3.18
10.83 3.43
10.56 3.55
10.12 3.75
9.74
3.60
9.03
3.03
11.84 3.15
11.58 3.25
10.95 3.51
10.68 3.63
10.20 3.75
9.83
3.60
9.12
3.03
11.87 2.80
11.60 2.90
10.97 3.13
10.71 3.24
10.26 3.43
9.99
3.55
9.19
3.03
10.66 2.62
10.42 2.71
9.85
2.93
9.61
3.03
9.21
3.21
8.97
3.32
8.44
3.03
10.95 2.93
10.71 3.03
10.13 3.27
9.88
3.38
9.47
3.58
9.18
3.60
8.55
3.03

125

Capacity Tables

Combination
(Capacity)
2.0+2.5+2.5+5.0

2.0+2.5+2.5+6.0

2.0+2.5+2.5+7.1

2.0+2.5+3.5+3.5

2.0+2.5+3.5+5.0

2.0+2.5+3.5+6.0

2.0+2.5+5.0+5.0

2.0+3.5+3.5+3.5

2.0+3.5+3.5+5.0

126

EDAU12-722

Outdoor
air temp.
CDB
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0

14C
TC
PI
kW
kW
9.45
2.74
9.18
2.84
8.57
3.09
8.31
3.21
7.87
3.42
7.61
3.55
7.23
3.03
9.60
2.81
9.33
2.91
8.71
3.17
8.44
3.29
8.00
3.50
7.73
3.60
7.34
3.03
9.66
2.88
9.39
2.98
8.76
3.24
8.49
3.36
8.05
3.58
7.78
3.60
7.40
3.03
9.14
2.79
8.89
2.89
8.30
3.15
8.04
3.27
7.62
3.48
7.37
3.60
7.05
3.03
9.60
2.87
9.33
2.97
8.71
3.23
8.44
3.35
8.00
3.57
7.73
3.60
7.36
3.03
9.66
2.87
9.39
2.97
8.76
3.23
8.49
3.35
8.05
3.57
7.78
3.60
7.40
3.03
9.66
2.56
9.39
2.65
8.76
2.88
8.49
2.99
8.05
3.18
7.78
3.30
7.36
3.03
9.28
2.79
9.03
2.89
8.42
3.15
8.17
3.27
7.74
3.48
7.48
3.60
7.14
3.03
9.66
2.87
9.39
2.97
8.76
3.23
8.49
3.35
8.05
3.57
7.78
3.60
7.40
3.03

16C
TC
PI
kW
kW
9.88
2.80
9.62
2.90
9.00
3.15
8.74
3.26
8.30
3.47
8.04
3.60
7.59
3.03
10.04 2.87
9.77
2.97
9.15
3.22
8.88
3.34
8.44
3.55
8.16
3.60
7.71
3.03
10.10 2.93
9.83
3.04
9.20
3.30
8.94
3.42
8.49
3.63
8.22
3.60
7.76
3.03
9.56
2.85
9.31
2.95
8.72
3.20
8.46
3.32
8.04
3.53
7.78
3.60
7.40
3.03
10.04 2.92
9.77
3.03
9.15
3.29
8.88
3.41
8.44
3.62
8.17
3.60
7.72
3.03
10.10 2.92
9.83
3.03
9.20
3.29
8.94
3.41
8.49
3.62
8.22
3.60
7.76
3.03
10.10 2.61
9.83
2.70
9.20
2.93
8.94
3.04
8.49
3.23
8.22
3.35
7.74
3.03
9.71
2.85
9.45
2.95
8.85
3.20
8.59
3.32
8.16
3.53
7.90
3.60
7.50
3.03
10.10 2.92
9.83
3.03
9.20
3.29
8.94
3.41
8.49
3.62
8.22
3.60
7.76
3.03

Indoor air temp.:CWB


18C
19C
TC
PI
TC
PI
kW
kW
kW
kW
10.31 2.85 10.53 2.88
10.05 2.95 10.26 2.98
9.44
3.20
9.65
3.23
9.17
3.32
9.39
3.34
8.74
3.52
8.95
3.55
8.46
3.60
8.67
3.60
7.95
3.03
8.12
3.03
10.48 2.92 10.69 2.95
10.21 3.02 10.43 3.05
9.59
3.28
9.81
3.30
9.32
3.40
9.54
3.42
8.88
3.61
9.10
3.63
8.59
3.60
8.80
3.60
8.06
3.03
8.23
3.03
10.54 2.99 10.76 3.02
10.27 3.09 10.49 3.12
9.65
3.35
9.87
3.38
9.38
3.48
9.60
3.50
8.93
3.69
9.15
3.72
8.64
3.60
8.85
3.60
8.12
3.03
8.29
3.03
9.98
2.90 10.19 2.93
9.73
3.00
9.94
3.03
9.13
3.26
9.34
3.29
8.88
3.38
9.09
3.40
8.46
3.59
8.67
3.61
8.20
3.60
8.40
3.60
7.75
3.03
7.92
3.03
10.48 2.98 10.69 3.01
10.21 3.08 10.43 3.11
9.59
3.34
9.81
3.37
9.32
3.47
9.54
3.49
8.88
3.68
9.10
3.71
8.59
3.60
8.79
3.60
8.07
3.03
8.25
3.03
10.54 2.98 10.76 3.01
10.27 3.08 10.49 3.11
9.65
3.34
9.87
3.37
9.38
3.47
9.60
3.49
8.93
3.68
9.15
3.71
8.64
3.60
8.85
3.60
8.11
3.03
8.29
3.03
10.54 2.66 10.76 2.68
10.27 2.75 10.49 2.77
9.65
2.98
9.87
3.01
9.38
3.09
9.60
3.11
8.93
3.28
9.15
3.30
8.66
3.40
8.88
3.43
8.12
3.03
8.30
3.03
10.13 2.90 10.35 2.93
9.88
3.00 10.09 3.03
9.28
3.26
9.49
3.29
9.02
3.38
9.23
3.40
8.59
3.59
8.80
3.61
8.32
3.60
8.52
3.60
7.84
3.03
8.01
3.03
10.54 2.98 10.76 3.01
10.27 3.08 10.49 3.11
9.65
3.34
9.87
3.37
9.38
3.47
9.60
3.49
8.93
3.68
9.15
3.71
8.64
3.60
8.85
3.60
8.11
3.03
8.29
3.03

22C
TC
PI
kW
kW
11.18 2.96
10.91 3.06
10.30 3.31
10.04 3.42
9.60
3.63
9.29
3.60
8.63
3.03
11.35 3.03
11.09 3.13
10.47 3.39
10.20 3.51
9.76
3.72
9.41
3.60
8.75
3.03
11.43 3.10
11.16 3.20
10.53 3.47
10.26 3.59
9.80
3.75
9.46
3.60
8.80
3.03
10.82 3.01
10.56 3.11
9.97
3.37
9.72
3.49
9.29
3.69
8.99
3.60
8.41
3.03
11.35 3.09
11.09 3.19
10.47 3.46
10.20 3.58
9.74
3.75
9.40
3.60
8.76
3.03
11.43 3.09
11.16 3.19
10.53 3.46
10.26 3.58
9.80
3.75
9.46
3.60
8.80
3.03
11.43 2.75
11.16 2.85
10.53 3.08
10.26 3.19
9.82
3.38
9.55
3.50
8.84
3.03
10.99 3.01
10.73 3.11
10.13 3.37
9.87
3.49
9.44
3.69
9.12
3.60
8.52
3.03
11.43 3.09
11.16 3.19
10.53 3.46
10.26 3.58
9.80
3.75
9.46
3.60
8.80
3.03

24C
TC
PI
kW
kW
11.61 3.01
11.35 3.11
10.73 3.36
10.47 3.48
10.03 3.68
9.68
3.60
8.97
3.03
11.79 3.08
11.53 3.19
10.91 3.44
10.64 3.56
10.19 3.75
9.81
3.60
9.08
3.03
11.87 3.16
11.60 3.26
10.97 3.52
10.71 3.64
10.22 3.75
9.85
3.60
9.13
3.03
11.24 3.07
10.98 3.17
10.39 3.42
10.14 3.54
9.71
3.75
9.38
3.60
8.74
3.03
11.79 3.15
11.53 3.25
10.91 3.51
10.64 3.63
10.16 3.75
9.80
3.60
9.09
3.03
11.87 3.15
11.60 3.25
10.97 3.51
10.71 3.63
10.22 3.75
9.85
3.60
9.13
3.03
11.87 2.80
11.60 2.90
10.97 3.13
10.71 3.24
10.26 3.43
9.99
3.55
9.19
3.03
11.41 3.07
11.15 3.17
10.55 3.42
10.29 3.54
9.86
3.75
9.51
3.60
8.84
3.03
11.87 3.15
11.60 3.25
10.97 3.51
10.71 3.63
10.22 3.75
9.85
3.60
9.13
3.03

SUPER MULTI NX E-Series Heat Pump

EDAU12-722

Combination
(Capacity)
2.5+2.5+2.5+2.5

2.5+2.5+2.5+3.5

2.5+2.5+2.5+5.0

2.5+2.5+2.5+6.0

2.5+2.5+3.5+3.5

2.5+2.5+3.5+5.0

2.5+2.5+3.5+6.0

2.5+3.5+3.5+3.5

2.5+3.5+3.5+5.0

Capacity Tables

Outdoor
air temp.
CDB
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0

SUPER MULTI NX E-Series Heat Pump

14C
TC
PI
kW
kW
8.87
2.67
8.63
2.77
8.05
3.01
7.80
3.12
7.39
3.32
7.15
3.45
6.84
3.03
8.97
2.67
8.72
2.77
8.14
3.01
7.89
3.12
7.48
3.32
7.23
3.45
6.91
3.03
9.53
2.80
9.26
2.90
8.64
3.16
8.38
3.28
7.94
3.49
7.67
3.60
7.30
3.03
9.64
2.87
9.37
2.97
8.74
3.23
8.48
3.35
8.03
3.57
7.76
3.60
7.39
3.03
9.09
2.79
8.84
2.89
8.25
3.15
8.00
3.27
7.58
3.48
7.33
3.60
7.02
3.03
9.64
2.87
9.37
2.97
8.74
3.23
8.48
3.35
8.03
3.57
7.76
3.60
7.39
3.03
9.66
2.87
9.39
2.97
8.76
3.23
8.49
3.35
8.05
3.57
7.78
3.60
7.40
3.03
9.39
2.79
9.13
2.89
8.53
3.15
8.26
3.27
7.83
3.48
7.57
3.60
7.21
3.03
9.66
2.87
9.39
2.97
8.76
3.23
8.49
3.35
8.05
3.57
7.78
3.60
7.40
3.03

16C
TC
PI
kW
kW
9.28
2.72
9.03
2.82
8.46
3.06
8.21
3.18
7.80
3.38
7.55
3.50
7.19
3.03
9.38
2.72
9.13
2.82
8.55
3.06
8.30
3.18
7.89
3.38
7.64
3.50
7.26
3.03
9.96
2.86
9.70
2.96
9.08
3.21
8.82
3.33
8.37
3.54
8.11
3.60
7.66
3.03
10.08 2.92
9.81
3.03
9.19
3.29
8.92
3.41
8.47
3.62
8.20
3.60
7.75
3.03
9.51
2.85
9.26
2.95
8.67
3.20
8.42
3.32
7.99
3.53
7.74
3.60
7.37
3.03
10.08 2.92
9.81
3.03
9.19
3.29
8.92
3.41
8.47
3.62
8.20
3.60
7.75
3.03
10.10 2.92
9.83
3.03
9.20
3.29
8.94
3.41
8.49
3.62
8.22
3.60
7.76
3.03
9.83
2.85
9.56
2.95
8.96
3.20
8.69
3.32
8.26
3.53
8.00
3.60
7.57
3.03
10.10 2.92
9.83
3.03
9.20
3.29
8.94
3.41
8.49
3.62
8.22
3.60
7.76
3.03

Indoor air temp.:CWB


18C
19C
TC
PI
TC
PI
kW
kW
kW
kW
9.68
2.77
9.89
2.80
9.44
2.87
9.64
2.90
8.86
3.11
9.07
3.14
8.62
3.23
8.82
3.25
8.21
3.43
8.41
3.45
7.96
3.55
8.16
3.58
7.53
3.03
7.70
3.03
9.79
2.77 10.00 2.80
9.55
2.87
9.75
2.90
8.96
3.11
9.17
3.14
8.71
3.23
8.92
3.25
8.30
3.43
8.50
3.45
8.05
3.55
8.26
3.58
7.60
3.03
7.77
3.03
10.40 2.91 10.62 2.94
10.13 3.01 10.35 3.04
9.52
3.27
9.73
3.30
9.25
3.39
9.47
3.41
8.81
3.60
9.03
3.62
8.53
3.60
8.74
3.60
8.01
3.03
8.18
3.03
10.52 2.98 10.74 3.01
10.25 3.08 10.47 3.11
9.63
3.34
9.85
3.37
9.36
3.47
9.58
3.49
8.91
3.68
9.13
3.71
8.62
3.60
8.83
3.60
8.10
3.03
8.27
3.03
9.93
2.90 10.13 2.93
9.67
3.00
9.88
3.03
9.08
3.26
9.29
3.29
8.83
3.38
9.04
3.40
8.41
3.59
8.62
3.61
8.15
3.60
8.35
3.60
7.71
3.03
7.88
3.03
10.52 2.98 10.74 3.01
10.25 3.08 10.47 3.11
9.63
3.34
9.85
3.37
9.36
3.47
9.58
3.49
8.91
3.68
9.13
3.71
8.62
3.60
8.83
3.60
8.10
3.03
8.27
3.03
10.54 2.98 10.76 3.01
10.27 3.08 10.49 3.11
9.65
3.34
9.87
3.37
9.38
3.47
9.60
3.49
8.93
3.68
9.15
3.71
8.64
3.60
8.85
3.60
8.11
3.03
8.29
3.03
10.26 2.90 10.47 2.93
9.99
3.00 10.21 3.03
9.39
3.26
9.60
3.29
9.12
3.38
9.34
3.40
8.69
3.59
8.91
3.61
8.42
3.60
8.62
3.60
7.92
3.03
8.09
3.03
10.54 2.98 10.76 3.01
10.27 3.08 10.49 3.11
9.65
3.34
9.87
3.37
9.38
3.47
9.60
3.49
8.93
3.68
9.15
3.71
8.64
3.60
8.85
3.60
8.11
3.03
8.29
3.03

22C
TC
PI
kW
kW
10.50 2.88
10.25 2.97
9.68
3.22
9.43
3.33
9.02
3.53
8.76
3.60
8.20
3.03
10.62 2.88
10.37 2.97
9.79
3.22
9.54
3.33
9.12
3.53
8.86
3.60
8.28
3.03
11.27 3.02
11.01 3.12
10.39 3.38
10.12 3.50
9.68
3.70
9.35
3.60
8.70
3.03
11.40 3.09
11.13 3.19
10.51 3.46
10.24 3.58
9.78
3.75
9.44
3.60
8.78
3.03
10.76 3.01
10.51 3.11
9.92
3.37
9.66
3.49
9.24
3.69
8.95
3.60
8.38
3.03
11.40 3.09
11.13 3.19
10.51 3.46
10.24 3.58
9.78
3.75
9.44
3.60
8.78
3.03
11.43 3.09
11.16 3.19
10.53 3.46
10.26 3.58
9.80
3.75
9.46
3.60
8.80
3.03
11.12 3.01
10.86 3.11
10.25 3.37
9.99
3.49
9.55
3.69
9.23
3.60
8.60
3.03
11.43 3.09
11.16 3.19
10.53 3.46
10.26 3.58
9.80
3.75
9.46
3.60
8.80
3.03

24C
TC
PI
kW
kW
10.90 2.93
10.66 3.03
10.08 3.27
9.84
3.38
9.43
3.58
9.14
3.60
8.52
3.03
11.03 2.93
10.78 3.03
10.20 3.27
9.95
3.38
9.53
3.58
9.24
3.60
8.60
3.03
11.71 3.08
11.44 3.18
10.83 3.43
10.56 3.55
10.12 3.75
9.74
3.60
9.03
3.03
11.84 3.15
11.58 3.25
10.95 3.51
10.68 3.63
10.20 3.75
9.83
3.60
9.12
3.03
11.18 3.07
10.92 3.17
10.33 3.42
10.08 3.54
9.66
3.75
9.33
3.60
8.70
3.03
11.84 3.15
11.58 3.25
10.95 3.51
10.68 3.63
10.20 3.75
9.83
3.60
9.12
3.03
11.87 3.15
11.60 3.25
10.97 3.51
10.71 3.63
10.22 3.75
9.85
3.60
9.13
3.03
11.55 3.07
11.29 3.17
10.68 3.42
10.42 3.54
9.98
3.75
9.62
3.60
8.93
3.03
11.87 3.15
11.60 3.25
10.97 3.51
10.71 3.63
10.22 3.75
9.85
3.60
9.13
3.03

127

Capacity Tables

Combination
(Capacity)
3.5+3.5+3.5+3.5

EDAU12-722

Outdoor
air temp.
CDB
22.0
25.0
32.0
35.0
40.0
43.0
46.0

Symbols

14C
TC
PI
kW
kW
9.10
2.79
8.85
2.89
8.26
3.15
8.01
3.27
7.59
3.48
7.33
3.60
7.03
3.03

16C
TC
PI
kW
kW
9.52
2.85
9.27
2.95
8.68
3.20
8.42
3.32
8.00
3.53
7.75
3.60
7.38
3.03

Indoor air temp.:CWB


18C
19C
TC
PI
TC
PI
kW
kW
kW
kW
9.94
2.90 10.15 2.93
9.68
3.00
9.89
3.03
9.09
3.26
9.30
3.29
8.84
3.38
9.05
3.40
8.42
3.59
8.63
3.61
8.16
3.60
8.36
3.60
7.72
3.03
7.89
3.03

22C
TC
PI
kW
kW
10.77 3.01
10.52 3.11
9.93
3.37
9.68
3.49
9.25
3.69
8.96
3.60
8.38
3.03

24C
TC
PI
kW
kW
11.19 3.07
10.94 3.17
10.35 3.42
10.09 3.54
9.67
3.75
9.34
3.60
8.71
3.03

NOTE:

TC

: Total capacity

(kW)

PI

: Power input

(kW)

Capacities are based on the following conditions.


Corresponding refrigerant piping length : 7.5m
Level difference : 0m
3D052671#1
3D052671#2
3D052671#3
3D052671#4
3D052671#5
3D052671#6
3D052671#7
3D052671#8
3D052671#9

128

SUPER MULTI NX E-Series Heat Pump

EDAU12-722

Capacity Tables

[Heating Capacity 50Hz / 60Hz 230V]


Combination
(Capacity)
2.0

2.5

3.5

5.0

6.0

7.1

2.0+2.0

2.0+2.5

2.0+3.5

Outdoor
air temp.
CWB
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0

SUPER MULTI NX E-Series Heat Pump

16C
TC
PI
kW
kW
2.27
1.04
2.73
1.10
3.19
1.15
3.66
1.20
4.21
1.27
4.58
1.31
5.05
1.36
2.52
1.12
3.03
1.18
3.55
1.24
4.06
1.30
4.68
1.36
5.09
1.41
5.60
1.47
2.73
1.45
3.29
1.52
3.85
1.60
4.41
1.67
5.08
1.76
5.52
1.82
5.78
1.73
3.83
1.80
4.61
1.90
5.39
1.99
6.17
2.08
7.11
2.19
7.74
2.26
8.52
2.36
4.38
2.13
5.28
2.24
6.17
2.34
7.07
2.45
8.14
2.58
8.85
2.67
9.68
2.74
4.81
2.40
5.80
2.53
6.78
2.65
7.76
2.77
8.94
2.92
9.73
3.01
10.58 3.06
3.62
1.50
4.36
1.57
5.10
1.65
5.84
1.73
6.73
1.82
7.32
1.88
8.06
1.95
3.79
1.56
4.56
1.64
5.34
1.72
6.11
1.80
7.04
1.90
7.66
1.96
8.43
2.04
4.07
1.83
4.90
1.92
5.73
2.01
6.56
2.11
7.55
2.22
8.22
2.29
9.05
2.39

18C
TC
PI
kW
kW
2.21
1.06
2.68
1.11
3.14
1.16
3.60
1.21
4.16
1.28
4.53
1.32
4.99
1.37
2.45
1.14
2.97
1.19
3.48
1.25
4.00
1.31
4.61
1.38
5.02
1.42
5.31
1.39
2.67
1.46
3.22
1.54
3.78
1.61
4.34
1.69
5.01
1.77
5.45
1.83
5.48
1.63
3.73
1.82
4.52
1.92
5.30
2.01
6.08
2.10
7.02
2.21
7.64
2.28
8.42
2.38
4.27
2.15
5.17
2.26
6.06
2.37
6.96
2.48
8.03
2.61
8.74
2.69
9.18
2.54
4.69
2.43
5.68
2.55
6.66
2.67
7.64
2.80
8.82
2.94
9.61
3.04
10.04 2.82
3.53
1.51
4.27
1.59
5.01
1.67
5.75
1.74
6.64
1.83
7.23
1.89
7.97
1.97
3.70
1.58
4.47
1.66
5.24
1.74
6.02
1.82
6.94
1.91
7.56
1.98
8.34
2.06
3.97
1.85
4.80
1.94
5.63
2.03
6.46
2.13
7.45
2.24
8.12
2.31
8.95
2.41

Indoor air temp.:CDB


20C
21C
TC
PI
TC
PI
kW
kW
kW
kW
2.16
1.07
2.13
1.07
2.62
1.12
2.59
1.13
3.08
1.17
3.05
1.18
3.54
1.23
3.52
1.23
4.10
1.29
4.07
1.30
4.47
1.33
4.44
1.34
4.93
1.39
4.91
1.39
2.39
1.15
2.36
1.16
2.91
1.21
2.87
1.21
3.42
1.26
3.39
1.27
3.93
1.32
3.90
1.33
4.55
1.39
4.52
1.40
4.96
1.44
4.88
1.42
5.02
1.31
4.88
1.27
2.60
1.48
2.56
1.49
3.15
1.55
3.12
1.56
3.71
1.63
3.68
1.64
4.27
1.70
4.24
1.71
4.94
1.79
4.91
1.80
5.18
1.73
5.04
1.68
5.18
1.53
5.04
1.48
3.64
1.84
3.59
1.85
4.42
1.94
4.37
1.95
5.20
2.03
5.15
2.04
5.98
2.12
5.93
2.13
6.92
2.23
6.87
2.24
7.55
2.30
7.50
2.31
8.15
2.30
7.92
2.21
4.16
2.18
4.11
2.19
5.06
2.28
5.00
2.30
5.95
2.39
5.90
2.40
6.85
2.50
6.79
2.51
7.92
2.63
7.87
2.64
8.64
2.72
8.44
2.64
8.69
2.35
8.44
2.26
4.57
2.46
4.51
2.47
5.56
2.58
5.50
2.59
6.54
2.70
6.48
2.71
7.52
2.82
7.46
2.84
8.70
2.97
8.64
2.98
9.49
3.07
9.23
2.94
9.50
2.60
9.23
2.49
3.44
1.53
3.40
1.54
4.18
1.61
4.14
1.61
4.92
1.68
4.88
1.69
5.66
1.76
5.62
1.77
6.55
1.85
6.50
1.86
7.14
1.91
7.10
1.92
7.88
1.99
7.84
2.00
3.60
1.60
3.55
1.60
4.37
1.68
4.33
1.68
5.15
1.76
5.10
1.76
5.92
1.83
5.87
1.84
6.85
1.93
6.80
1.94
7.47
1.99
7.42
2.00
8.24
2.07
8.19
2.08
3.86
1.87
3.81
1.88
4.69
1.96
4.64
1.97
5.52
2.06
5.47
2.07
6.35
2.15
6.30
2.16
7.35
2.26
7.30
2.27
8.01
2.33
7.96
2.34
8.84
2.43
8.79
2.44

22C
TC
PI
kW
kW
2.10
1.08
2.56
1.13
3.02
1.18
3.49
1.24
4.04
1.30
4.41
1.34
4.88
1.40
2.33
1.16
2.84
1.22
3.36
1.28
3.87
1.33
4.49
1.40
4.74
1.38
4.74
1.23
2.53
1.50
3.09
1.57
3.64
1.64
4.20
1.72
4.87
1.81
4.89
1.62
4.89
1.43
3.54
1.86
4.32
1.96
5.11
2.05
5.89
2.14
6.82
2.25
7.45
2.32
7.69
2.12
4.05
2.20
4.95
2.31
5.84
2.42
6.74
2.52
7.81
2.65
8.19
2.53
8.19
2.17
4.45
2.48
5.44
2.61
6.42
2.73
7.40
2.85
8.58
3.00
8.95
2.81
8.95
2.39
3.35
1.55
4.09
1.62
4.83
1.70
5.57
1.78
6.46
1.87
7.05
1.93
7.79
2.00
3.51
1.61
4.28
1.69
5.05
1.77
5.83
1.85
6.76
1.95
7.37
2.01
8.15
2.09
3.76
1.89
4.59
1.98
5.42
2.08
6.25
2.17
7.25
2.28
7.91
2.35
8.74
2.45

24C
TC
PI
kW
kW
2.04
1.09
2.51
1.14
2.97
1.20
3.43
1.25
3.99
1.31
4.36
1.36
4.63
1.32
2.27
1.17
2.78
1.23
3.29
1.29
3.81
1.35
4.42
1.42
4.45
1.29
4.45
1.15
2.46
1.51
3.02
1.59
3.58
1.66
4.13
1.73
4.59
1.69
4.59
1.51
4.59
1.34
3.45
1.88
4.23
1.98
5.01
2.07
5.79
2.16
6.73
2.27
7.22
2.26
7.22
1.96
3.95
2.22
4.84
2.33
5.73
2.44
6.63
2.55
7.70
2.67
7.70
2.32
7.70
1.99
4.33
2.51
5.32
2.63
6.30
2.75
7.28
2.88
8.41
2.99
8.41
2.56
8.41
2.18
3.26
1.56
4.00
1.64
4.74
1.72
5.48
1.79
6.37
1.88
6.96
1.94
7.70
2.02
3.41
1.63
4.19
1.71
4.96
1.79
5.73
1.87
6.66
1.96
7.28
2.03
8.05
2.11
3.66
1.91
4.49
2.00
5.32
2.10
6.15
2.19
7.15
2.30
7.81
2.38
8.64
2.47

129

Capacity Tables

Combination
(Capacity)
2.0+5.0

2.0+6.0

2.0+7.1

2.5+2.5

2.5+3.5

2.5+5.0

2.5+6.0

2.5+7.1

3.5+3.5

130

EDAU12-722

Outdoor
air temp.
CWB
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0

16C
TC
PI
kW
kW
4.72
1.94
5.68
2.04
6.65
2.14
7.61
2.24
8.77
2.36
9.54
2.44
10.50 2.53
5.17
2.14
6.23
2.24
7.29
2.35
8.34
2.46
9.61
2.59
10.45 2.68
11.51 2.79
5.54
2.30
6.68
2.41
7.81
2.53
8.94
2.65
10.30 2.79
11.20 2.88
12.33 3.00
3.83
1.76
4.61
1.84
5.39
1.93
6.17
2.02
7.11
2.13
7.74
2.20
8.52
2.29
4.56
2.16
5.49
2.27
6.42
2.38
7.35
2.49
8.47
2.62
9.21
2.71
10.14 2.82
5.06
2.15
6.09
2.26
7.12
2.37
8.15
2.48
9.39
2.61
10.22 2.70
11.25 2.81
5.41
2.38
6.51
2.50
7.61
2.62
8.72
2.74
10.04 2.89
10.92 2.98
12.03 3.10
5.54
2.33
6.68
2.45
7.81
2.57
8.94
2.69
10.30 2.83
11.20 2.92
12.33 3.04
4.91
2.52
5.91
2.64
6.91
2.77
7.91
2.90
9.11
3.05
9.92
3.16
10.92 3.28

18C
TC
PI
kW
kW
4.60
1.96
5.57
2.06
6.53
2.16
7.49
2.26
8.65
2.38
9.42
2.46
10.38 2.56
5.04
2.16
6.10
2.27
7.16
2.38
8.21
2.49
9.48
2.62
10.32 2.70
11.38 2.81
5.41
2.32
6.54
2.44
7.67
2.56
8.80
2.67
10.16 2.81
11.06 2.91
12.19 3.02
3.73
1.78
4.52
1.86
5.30
1.95
6.08
2.04
7.02
2.15
7.64
2.22
8.42
2.31
4.45
2.18
5.38
2.29
6.31
2.40
7.24
2.51
8.35
2.65
9.10
2.73
10.03 2.84
4.93
2.18
5.96
2.29
7.00
2.40
8.03
2.50
9.27
2.64
10.09 2.72
11.12 2.83
5.27
2.41
6.37
2.53
7.48
2.65
8.58
2.77
9.90
2.91
10.79 3.01
11.89 3.13
5.41
2.36
6.54
2.47
7.67
2.59
8.80
2.71
10.16 2.85
11.06 2.95
12.19 3.07
4.79
2.54
5.79
2.67
6.79
2.80
7.79
2.93
8.99
3.08
9.79
3.18
10.80 3.31

Indoor air temp.:CDB


20C
21C
TC
PI
TC
PI
kW
kW
kW
kW
4.48
1.98
4.43
2.00
5.45
2.08
5.39
2.09
6.41
2.18
6.35
2.19
7.37
2.28
7.32
2.29
8.53
2.40
8.47
2.41
9.30
2.48
9.24
2.49
10.26 2.58 10.20 2.59
4.92
2.18
4.85
2.20
5.97
2.29
5.91
2.30
7.03
2.40
6.96
2.41
8.08
2.51
8.02
2.52
9.35
2.64
9.29
2.65
10.19 2.73 10.13 2.74
11.25 2.84 11.19 2.85
5.27
2.35
5.20
2.36
6.40
2.47
6.33
2.48
7.53
2.58
7.46
2.60
8.66
2.70
8.59
2.71
10.02 2.84
9.95
2.85
10.93 2.93 10.86 2.95
12.06 3.05 11.99 3.06
3.64
1.79
3.59
1.80
4.42
1.88
4.37
1.89
5.20
1.97
5.15
1.98
5.98
2.06
5.93
2.07
6.92
2.17
6.87
2.18
7.55
2.24
7.50
2.25
8.33
2.33
8.28
2.34
4.33
2.21
4.28
2.22
5.26
2.32
5.21
2.33
6.19
2.43
6.14
2.44
7.12
2.54
7.07
2.55
8.24
2.67
8.18
2.68
8.98
2.76
8.93
2.77
9.91
2.87
9.86
2.88
4.81
2.20
4.74
2.21
5.84
2.31
5.77
2.32
6.87
2.42
6.81
2.43
7.90
2.53
7.84
2.54
9.14
2.66
9.08
2.67
9.97
2.75
9.90
2.76
11.00 2.86 10.93 2.87
5.14
2.43
5.07
2.44
6.24
2.55
6.17
2.57
7.34
2.67
7.28
2.69
8.45
2.79
8.38
2.81
9.77
2.94
9.70
2.95
10.65 3.04 10.59 3.05
11.76 3.16 11.69 3.17
5.27
2.38
5.20
2.39
6.40
2.50
6.33
2.51
7.53
2.62
7.46
2.63
8.66
2.74
8.59
2.75
10.02 2.88
9.95
2.89
10.93 2.97 10.86 2.99
12.06 3.09 11.99 3.11
4.66
2.57
4.60
2.59
5.66
2.70
5.60
2.71
6.67
2.83
6.61
2.84
7.67
2.96
7.61
2.97
8.87
3.11
8.81
3.12
9.67
3.21
9.61
3.23
10.37 3.13 10.07 2.99

22C
TC
PI
kW
kW
4.37
2.01
5.33
2.11
6.29
2.20
7.26
2.30
8.41
2.42
9.18
2.50
10.15 2.60
4.79
2.21
5.84
2.32
6.90
2.42
7.95
2.53
9.22
2.66
10.07 2.75
11.12 2.86
5.13
2.37
6.26
2.49
7.39
2.61
8.52
2.73
9.88
2.87
10.79 2.96
11.92 3.08
3.54
1.81
4.32
1.90
5.11
1.99
5.89
2.08
6.82
2.19
7.45
2.26
8.23
2.35
4.22
2.23
5.15
2.34
6.08
2.45
7.01
2.56
8.13
2.69
8.87
2.78
9.63
2.78
4.68
2.22
5.71
2.33
6.74
2.44
7.78
2.55
9.01
2.68
9.84
2.77
10.87 2.88
5.00
2.46
6.10
2.58
7.21
2.70
8.31
2.82
9.64
2.97
10.52 3.06
11.62 3.18
5.13
2.41
6.26
2.53
7.39
2.65
8.52
2.76
9.88
2.91
10.79 3.00
11.92 3.12
4.54
2.60
5.54
2.73
6.54
2.86
7.55
2.98
8.75
3.14
9.55
3.24
9.78
2.85

24C
TC
PI
kW
kW
4.25
2.03
5.21
2.13
6.18
2.23
7.14
2.32
8.29
2.44
9.07
2.52
10.03 2.62
4.66
2.23
5.71
2.34
6.77
2.45
7.82
2.56
9.09
2.69
9.94
2.77
10.99 2.88
4.99
2.40
6.12
2.52
7.25
2.63
8.39
2.75
9.74
2.89
10.65 2.98
11.78 3.10
3.45
1.83
4.23
1.92
5.01
2.01
5.79
2.10
6.73
2.21
7.35
2.28
8.14
2.37
4.10
2.26
5.04
2.37
5.97
2.48
6.90
2.59
8.01
2.72
8.76
2.81
9.04
2.53
4.55
2.25
5.58
2.36
6.62
2.47
7.65
2.58
8.89
2.71
9.71
2.80
10.75 2.91
4.87
2.48
5.97
2.61
7.07
2.73
8.18
2.85
9.50
2.99
10.38 3.09
11.49 3.21
4.99
2.43
6.12
2.55
7.25
2.67
8.39
2.79
9.74
2.93
10.65 3.03
11.78 3.15
4.42
2.63
5.42
2.76
6.42
2.88
7.42
3.01
8.63
3.17
9.18
3.08
9.18
2.59

SUPER MULTI NX E-Series Heat Pump

EDAU12-722

Combination
(Capacity)
3.5+5.0

3.5+6.0

3.5+7.1

5.0+5.0

5.0+6.0

5.0+7.1

6.0+6.0

6.0+7.1

7.1+7.1

Capacity Tables

Outdoor
air temp.
CWB
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0

SUPER MULTI NX E-Series Heat Pump

16C
TC
PI
kW
kW
5.39
2.32
6.49
2.44
7.59
2.56
8.69
2.68
10.01 2.82
10.89 2.91
11.99 3.03
5.53
2.31
6.66
2.42
7.79
2.54
8.92
2.66
10.28 2.80
11.18 2.89
12.31 3.01
5.55
2.25
6.68
2.36
7.82
2.48
8.95
2.59
10.31 2.73
11.21 2.82
12.35 2.94
5.68
2.23
6.84
2.35
8.00
2.46
9.16
2.57
10.55 2.71
11.48 2.80
12.64 2.91
5.71
2.22
6.87
2.33
8.03
2.44
9.20
2.56
10.59 2.69
11.53 2.78
12.69 2.89
5.72
2.21
6.89
2.32
8.06
2.43
9.22
2.55
10.63 2.68
11.56 2.77
12.73 2.88
5.73
2.25
6.90
2.36
8.06
2.48
9.23
2.59
10.64 2.73
11.57 2.82
12.74 2.94
5.74
2.24
6.92
2.36
8.09
2.47
9.26
2.58
10.67 2.72
11.60 2.81
12.78 2.93
5.76
2.18
6.94
2.30
8.11
2.41
9.29
2.52
10.70 2.65
11.64 2.74
12.81 2.85

18C
TC
PI
kW
kW
5.26
2.35
6.36
2.47
7.45
2.58
8.55
2.70
9.87
2.84
10.75 2.94
11.85 3.06
5.40
2.33
6.52
2.45
7.65
2.57
8.78
2.68
10.14 2.82
11.04 2.92
12.17 3.04
5.41
2.27
6.54
2.39
7.68
2.50
8.81
2.62
10.17 2.75
11.07 2.85
12.21 2.96
5.54
2.26
6.70
2.37
7.86
2.49
9.02
2.60
10.41 2.74
11.34 2.83
12.50 2.94
5.56
2.24
6.73
2.35
7.89
2.47
9.06
2.58
10.45 2.72
11.38 2.81
12.55 2.92
5.58
2.23
6.75
2.35
7.91
2.46
9.08
2.57
10.48 2.71
11.42 2.80
12.58 2.91
5.58
2.27
6.75
2.39
7.92
2.50
9.09
2.62
10.49 2.75
11.43 2.85
12.60 2.96
5.60
2.27
6.77
2.38
7.94
2.49
9.12
2.61
10.52 2.75
11.46 2.84
12.63 2.95
5.62
2.21
6.79
2.32
7.97
2.43
9.14
2.54
10.55 2.68
11.49 2.76
12.67 2.88

Indoor air temp.:CDB


20C
21C
TC
PI
TC
PI
kW
kW
kW
kW
5.12
2.37
5.05
2.39
6.22
2.49
6.15
2.50
7.32
2.61
7.25
2.62
8.42
2.73
8.35
2.74
9.74
2.87
9.67
2.88
10.62 2.96 10.55 2.98
11.72 3.08 11.65 3.10
5.26
2.36
5.19
2.37
6.39
2.47
6.32
2.49
7.52
2.59
7.45
2.60
8.64
2.71
8.58
2.72
10.00 2.85
9.93
2.86
10.90 2.94 10.83 2.96
12.03 3.06 11.96 3.07
5.27
2.30
5.20
2.31
6.41
2.41
6.34
2.43
7.54
2.53
7.47
2.54
8.67
2.64
8.60
2.66
10.03 2.78
9.96
2.79
10.94 2.87 10.87 2.88
12.07 2.99 12.00 3.00
5.40
2.28
5.33
2.30
6.56
2.40
6.49
2.41
7.72
2.51
7.65
2.52
8.88
2.62
8.81
2.64
10.27 2.76 10.20 2.77
11.20 2.85 11.13 2.86
12.36 2.96 12.29 2.98
5.42
2.27
5.35
2.28
6.58
2.38
6.51
2.39
7.75
2.49
7.68
2.50
8.91
2.60
8.84
2.62
10.31 2.74 10.24 2.75
11.24 2.83 11.17 2.84
12.41 2.94 12.33 2.96
5.44
2.26
5.36
2.27
6.60
2.37
6.53
2.38
7.77
2.48
7.70
2.49
8.94
2.60
8.87
2.61
10.34 2.73 10.27 2.74
11.27 2.82 11.20 2.83
12.44 2.93 12.37 2.94
5.44
2.30
5.37
2.31
6.61
2.41
6.54
2.43
7.78
2.53
7.71
2.54
8.95
2.64
8.88
2.66
10.35 2.78 10.28 2.79
11.28 2.87 11.21 2.88
12.45 2.99 12.38 3.00
5.46
2.29
5.39
2.30
6.63
2.40
6.56
2.42
7.80
2.52
7.73
2.53
8.97
2.63
8.90
2.65
10.38 2.77 10.31 2.78
11.32 2.86 11.25 2.87
12.49 2.98 12.42 2.99
5.47
2.23
5.40
2.25
6.65
2.34
6.58
2.36
7.82
2.46
7.75
2.47
9.00
2.57
8.93
2.58
10.41 2.70 10.34 2.71
11.35 2.79 11.28 2.80
12.53 2.90 12.45 2.91

22C
TC
PI
kW
kW
4.99
2.40
6.09
2.52
7.19
2.64
8.29
2.75
9.61
2.90
10.49 2.99
11.59 3.11
5.12
2.38
6.25
2.50
7.38
2.62
8.51
2.73
9.86
2.88
10.77 2.97
11.89 3.09
5.13
2.32
6.27
2.44
7.40
2.55
8.53
2.67
9.89
2.81
10.80 2.90
11.93 3.01
5.26
2.31
6.42
2.42
7.58
2.53
8.74
2.65
10.13 2.78
11.06 2.88
12.22 2.99
5.28
2.29
6.44
2.40
7.61
2.52
8.77
2.63
10.17 2.76
11.10 2.85
12.26 2.97
5.29
2.28
6.46
2.39
7.63
2.51
8.80
2.62
10.20 2.75
11.13 2.84
12.30 2.96
5.30
2.32
6.47
2.44
7.64
2.55
8.80
2.67
10.21 2.81
11.14 2.90
12.31 3.01
5.31
2.32
6.49
2.43
7.66
2.54
8.83
2.66
10.24 2.79
11.17 2.89
12.35 3.00
5.33
2.26
6.50
2.37
7.68
2.48
8.86
2.59
10.27 2.72
11.21 2.81
12.38 2.92

24C
TC
PI
kW
kW
4.85
2.43
5.95
2.54
7.05
2.66
8.15
2.78
9.47
2.92
10.35 3.02
11.45 3.13
4.98
2.41
6.11
2.53
7.24
2.64
8.37
2.76
9.72
2.90
10.63 3.00
11.76 3.11
5.00
2.35
6.13
2.46
7.26
2.58
8.39
2.69
9.75
2.83
10.66 2.92
11.79 3.04
5.12
2.33
6.28
2.45
7.44
2.56
8.59
2.67
9.99
2.81
10.91 2.90
12.07 3.01
5.14
2.32
6.30
2.43
7.46
2.54
8.63
2.65
10.03 2.79
10.96 2.88
12.12 2.99
5.15
2.31
6.32
2.42
7.49
2.53
8.65
2.64
10.05 2.78
10.99 2.87
12.16 2.98
5.16
2.35
6.32
2.46
7.49
2.58
8.66
2.69
10.06 2.83
11.00 2.92
12.17 3.04
5.17
2.34
6.34
2.45
7.51
2.57
8.69
2.68
10.09 2.82
11.03 2.91
12.20 3.03
5.19
2.28
6.36
2.39
7.54
2.50
8.71
2.62
10.12 2.75
11.06 2.84
12.24 2.95

131

Capacity Tables

Combination
(Capacity)
2.0+2.0+2.0

2.0+2.0+2.5

2.0+2.0+3.5

2.0+2.0+5.0

2.0+2.0+6.0

2.0+2.0+7.1

2.0+2.5+2.5

2.0+2.5+3.5

2.0+2.5+5.0

132

EDAU12-722

Outdoor
air temp.
CWB
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0

16C
TC
PI
kW
kW
4.45
1.76
5.36
1.84
6.27
1.93
7.18
2.02
8.27
2.13
9.00
2.20
9.91
2.29
4.78
1.91
5.76
2.01
6.73
2.10
7.71
2.20
8.88
2.32
9.66
2.40
10.63 2.49
5.18
2.14
6.24
2.24
7.30
2.35
8.36
2.46
9.63
2.59
10.48 2.68
11.53 2.79
5.71
2.22
6.88
2.33
8.04
2.44
9.21
2.56
10.60 2.69
11.54 2.78
12.70 2.89
5.73
2.20
6.90
2.31
8.06
2.42
9.23
2.54
10.64 2.67
11.57 2.76
12.74 2.87
5.75
2.19
6.92
2.30
8.10
2.42
9.27
2.53
10.68 2.66
11.62 2.75
12.79 2.86
4.78
1.89
5.76
1.99
6.73
2.09
7.71
2.18
8.88
2.30
9.66
2.37
10.63 2.47
5.18
2.11
6.24
2.22
7.30
2.33
8.36
2.43
9.63
2.56
10.48 2.65
11.53 2.76
5.71
2.22
6.88
2.33
8.04
2.44
9.21
2.56
10.60 2.69
11.54 2.78
12.70 2.89

18C
TC
PI
kW
kW
4.34
1.78
5.25
1.86
6.16
1.95
7.07
2.04
8.16
2.15
8.89
2.22
9.80
2.31
4.66
1.93
5.64
2.03
6.61
2.12
7.59
2.22
8.76
2.34
9.54
2.42
10.52 2.51
5.06
2.16
6.11
2.27
7.17
2.38
8.23
2.49
9.50
2.62
10.35 2.70
11.40 2.81
5.57
2.24
6.73
2.35
7.90
2.47
9.06
2.58
10.46 2.72
11.39 2.81
12.56 2.92
5.58
2.23
6.75
2.34
7.92
2.45
9.09
2.56
10.49 2.70
11.43 2.79
12.60 2.90
5.61
2.22
6.78
2.33
7.95
2.44
9.13
2.55
10.53 2.69
11.47 2.77
12.65 2.89
4.66
1.91
5.64
2.01
6.61
2.11
7.59
2.20
8.76
2.32
9.54
2.40
10.52 2.49
5.06
2.14
6.11
2.24
7.17
2.35
8.23
2.46
9.50
2.59
10.35 2.67
11.40 2.78
5.57
2.24
6.73
2.35
7.90
2.47
9.06
2.58
10.46 2.72
11.39 2.81
12.56 2.92

Indoor air temp.:CDB


20C
21C
TC
PI
TC
PI
kW
kW
kW
kW
4.23
1.79
4.18
1.80
5.14
1.88
5.09
1.89
6.05
1.97
5.99
1.98
6.96
2.06
6.90
2.07
8.05
2.17
7.99
2.18
8.78
2.24
8.72
2.25
9.69
2.33
9.63
2.34
4.54
1.95
4.48
1.96
5.52
2.05
5.46
2.06
6.49
2.15
6.43
2.16
7.47
2.24
7.41
2.25
8.64
2.36
8.58
2.37
9.42
2.44
9.36
2.45
10.40 2.53 10.34 2.55
4.93
2.18
4.86
2.20
5.98
2.29
5.92
2.30
7.04
2.40
6.98
2.41
8.10
2.51
8.04
2.52
9.37
2.64
9.31
2.65
10.22 2.73 10.15 2.74
11.27 2.84 11.21 2.85
5.43
2.27
5.35
2.28
6.59
2.38
6.52
2.39
7.76
2.49
7.69
2.50
8.92
2.60
8.85
2.62
10.32 2.74 10.25 2.75
11.25 2.83 11.18 2.84
12.42 2.94 12.35 2.96
5.44
2.25
5.37
2.26
6.61
2.36
6.54
2.37
7.78
2.47
7.71
2.49
8.95
2.59
8.88
2.60
10.35 2.72 10.28 2.73
11.28 2.81 11.21 2.82
12.45 2.92 12.38 2.93
5.46
2.24
5.39
2.25
6.64
2.35
6.56
2.37
7.81
2.46
7.74
2.48
8.98
2.58
8.91
2.59
10.39 2.71 10.32 2.72
11.33 2.80 11.26 2.81
12.50 2.91 12.43 2.92
4.54
1.94
4.48
1.95
5.52
2.03
5.46
2.04
6.49
2.13
6.43
2.14
7.47
2.22
7.41
2.23
8.64
2.34
8.58
2.35
9.42
2.42
9.36
2.43
10.40 2.51 10.34 2.52
4.93
2.16
4.86
2.17
5.98
2.27
5.92
2.28
7.04
2.37
6.98
2.39
8.10
2.48
8.04
2.49
9.37
2.61
9.31
2.62
10.22 2.70 10.15 2.71
11.27 2.80 11.21 2.82
5.43
2.27
5.35
2.28
6.59
2.38
6.52
2.39
7.76
2.49
7.69
2.50
8.92
2.60
8.85
2.62
10.32 2.74 10.25 2.75
11.25 2.83 11.18 2.84
12.42 2.94 12.35 2.96

22C
TC
PI
kW
kW
4.12
1.81
5.03
1.90
5.94
1.99
6.85
2.08
7.94
2.19
8.67
2.26
9.58
2.35
4.42
1.97
5.40
2.07
6.37
2.17
7.35
2.26
8.52
2.38
9.30
2.46
10.28 2.56
4.80
2.21
5.85
2.32
6.91
2.42
7.97
2.53
9.24
2.66
10.09 2.75
11.15 2.86
5.28
2.29
6.45
2.40
7.61
2.52
8.78
2.63
10.18 2.76
11.11 2.85
12.28 2.97
5.30
2.27
6.47
2.39
7.64
2.50
8.80
2.61
10.21 2.74
11.14 2.83
12.31 2.95
5.32
2.27
6.49
2.38
7.67
2.49
8.84
2.60
10.25 2.73
11.19 2.82
12.36 2.94
4.42
1.96
5.40
2.05
6.37
2.15
7.35
2.25
8.52
2.36
9.30
2.44
10.28 2.53
4.80
2.18
5.85
2.29
6.91
2.40
7.97
2.50
9.24
2.63
10.09 2.72
11.15 2.83
5.28
2.29
6.45
2.40
7.61
2.52
8.78
2.63
10.18 2.76
11.11 2.85
12.28 2.97

24C
TC
PI
kW
kW
4.01
1.83
4.92
1.92
5.83
2.01
6.74
2.10
7.83
2.21
8.55
2.28
9.46
2.37
4.30
1.99
5.28
2.09
6.26
2.19
7.23
2.29
8.40
2.40
9.18
2.48
10.16 2.58
4.67
2.23
5.73
2.34
6.78
2.45
7.84
2.56
9.11
2.69
9.96
2.77
11.02 2.88
5.14
2.32
6.31
2.43
7.47
2.54
8.64
2.65
10.04 2.79
10.97 2.88
12.13 2.99
5.16
2.30
6.32
2.41
7.49
2.52
8.66
2.63
10.06 2.77
11.00 2.86
12.17 2.97
5.18
2.29
6.35
2.40
7.52
2.51
8.70
2.62
10.10 2.76
11.04 2.85
12.21 2.96
4.30
1.98
5.28
2.07
6.26
2.17
7.23
2.27
8.40
2.38
9.18
2.46
10.16 2.56
4.67
2.21
5.73
2.31
6.78
2.42
7.84
2.53
9.11
2.66
9.96
2.74
11.02 2.85
5.14
2.32
6.31
2.43
7.47
2.54
8.64
2.65
10.04 2.79
10.97 2.88
12.13 2.99

SUPER MULTI NX E-Series Heat Pump

EDAU12-722

Combination
(Capacity)
2.0+2.5+6.0

2.0+2.5+7.1

2.0+3.5+3.5

2.0+3.5+5.0

2.0+3.5+6.0

2.0+3.5+7.1

2.0+5.0+5.0

2.0+5.0+6.0

2.0+5.0+7.1

Capacity Tables

Outdoor
air temp.
CWB
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0

SUPER MULTI NX E-Series Heat Pump

16C
TC
PI
kW
kW
5.73
2.20
6.90
2.31
8.06
2.42
9.23
2.54
10.64 2.67
11.57 2.76
12.74 2.87
5.75
2.19
6.92
2.30
8.10
2.42
9.27
2.53
10.68 2.66
11.62 2.75
12.79 2.86
5.54
2.26
6.67
2.37
7.80
2.49
8.93
2.60
10.29 2.74
11.19 2.83
12.32 2.95
5.71
2.22
6.88
2.33
8.04
2.44
9.21
2.56
10.60 2.69
11.54 2.78
12.70 2.89
5.73
2.20
6.90
2.31
8.07
2.42
9.24
2.54
10.65 2.67
11.58 2.76
12.75 2.87
5.75
2.19
6.92
2.30
8.10
2.42
9.27
2.53
10.68 2.66
11.62 2.75
12.79 2.86
5.89
2.16
7.09
2.27
8.29
2.38
9.49
2.49
10.93 2.62
11.89 2.71
13.10 2.82
5.90
2.15
7.11
2.26
8.31
2.37
9.52
2.48
10.96 2.61
11.93 2.70
13.13 2.81
5.93
2.14
7.14
2.24
8.35
2.35
9.55
2.46
11.01 2.59
11.97 2.68
13.18 2.79

18C
TC
PI
kW
kW
5.58
2.23
6.75
2.34
7.92
2.45
9.09
2.56
10.49 2.70
11.43 2.79
12.60 2.90
5.61
2.22
6.78
2.33
7.95
2.44
9.13
2.55
10.53 2.69
11.47 2.77
12.65 2.89
5.40
2.28
6.53
2.40
7.66
2.51
8.79
2.63
10.15 2.76
11.05 2.86
12.18 2.97
5.57
2.24
6.73
2.35
7.90
2.47
9.06
2.58
10.46 2.72
11.39 2.81
12.56 2.92
5.59
2.23
6.76
2.34
7.93
2.45
9.10
2.56
10.50 2.70
11.44 2.79
12.61 2.90
5.61
2.22
6.78
2.33
7.95
2.44
9.13
2.55
10.53 2.69
11.47 2.77
12.65 2.89
5.74
2.18
6.94
2.29
8.14
2.40
9.35
2.51
10.79 2.65
11.75 2.73
12.95 2.84
5.76
2.18
6.96
2.29
8.17
2.40
9.37
2.50
10.82 2.64
11.78 2.72
12.99 2.83
5.78
2.16
6.99
2.27
8.20
2.38
9.41
2.49
10.86 2.62
11.83 2.70
13.03 2.81

Indoor air temp.:CDB


20C
21C
TC
PI
TC
PI
kW
kW
kW
kW
5.44
2.25
5.37
2.26
6.61
2.36
6.54
2.37
7.78
2.47
7.71
2.49
8.95
2.59
8.88
2.60
10.35 2.72 10.28 2.73
11.28 2.81 11.21 2.82
12.45 2.92 12.38 2.93
5.46
2.24
5.39
2.25
6.64
2.35
6.56
2.37
7.81
2.46
7.74
2.48
8.98
2.58
8.91
2.59
10.39 2.71 10.32 2.72
11.33 2.80 11.26 2.81
12.50 2.91 12.43 2.92
5.26
2.31
5.19
2.32
6.39
2.42
6.32
2.43
7.52
2.54
7.45
2.55
8.65
2.65
8.58
2.66
10.01 2.79
9.94
2.80
10.91 2.88 10.85 2.89
12.04 3.00 11.98 3.01
5.43
2.27
5.35
2.28
6.59
2.38
6.52
2.39
7.76
2.49
7.69
2.50
8.92
2.60
8.85
2.62
10.32 2.74 10.25 2.75
11.25 2.83 11.18 2.84
12.42 2.94 12.35 2.96
5.45
2.25
5.38
2.26
6.62
2.36
6.55
2.37
7.79
2.47
7.71
2.49
8.96
2.59
8.88
2.60
10.36 2.72 10.29 2.73
11.30 2.81 11.22 2.82
12.47 2.92 12.39 2.93
5.46
2.24
5.39
2.25
6.64
2.35
6.56
2.37
7.81
2.46
7.74
2.48
8.98
2.58
8.91
2.59
10.39 2.71 10.32 2.72
11.33 2.80 11.26 2.81
12.50 2.91 12.43 2.92
5.59
2.21
5.52
2.22
6.80
2.32
6.72
2.33
8.00
2.43
7.92
2.44
9.20
2.54
9.12
2.55
10.64 2.67 10.57 2.68
11.60 2.76 11.53 2.77
12.80 2.87 12.73 2.88
5.61
2.20
5.54
2.21
6.81
2.31
6.74
2.32
8.02
2.42
7.95
2.43
9.22
2.53
9.15
2.54
10.67 2.66 10.60 2.67
11.63 2.75 11.56 2.76
12.84 2.86 12.77 2.87
5.63
2.18
5.56
2.20
6.84
2.29
6.77
2.30
8.05
2.40
7.98
2.41
9.26
2.51
9.18
2.52
10.71 2.64 10.64 2.65
11.68 2.73 11.60 2.74
12.89 2.84 12.81 2.85

22C
TC
PI
kW
kW
5.30
2.27
6.47
2.39
7.64
2.50
8.80
2.61
10.21 2.74
11.14 2.83
12.31 2.95
5.32
2.27
6.49
2.38
7.67
2.49
8.84
2.60
10.25 2.73
11.19 2.82
12.36 2.94
5.12
2.33
6.25
2.45
7.39
2.56
8.52
2.68
9.87
2.82
10.78 2.91
11.91 3.02
5.28
2.29
6.45
2.40
7.61
2.52
8.78
2.63
10.18 2.76
11.11 2.85
12.28 2.97
5.30
2.27
6.47
2.39
7.64
2.50
8.81
2.61
10.22 2.74
11.15 2.83
12.32 2.95
5.32
2.27
6.49
2.38
7.67
2.49
8.84
2.60
10.25 2.73
11.19 2.82
12.36 2.94
5.45
2.23
6.65
2.34
7.85
2.45
9.05
2.56
10.49 2.69
11.45 2.78
12.66 2.89
5.46
2.22
6.67
2.33
7.87
2.44
9.08
2.55
10.52 2.68
11.49 2.77
12.69 2.88
5.48
2.21
6.69
2.32
7.90
2.42
9.11
2.53
10.56 2.66
11.53 2.75
12.74 2.86

24C
TC
PI
kW
kW
5.16
2.30
6.32
2.41
7.49
2.52
8.66
2.63
10.06 2.77
11.00 2.86
12.17 2.97
5.18
2.29
6.35
2.40
7.52
2.51
8.70
2.62
10.10 2.76
11.04 2.85
12.21 2.96
4.99
2.36
6.12
2.47
7.25
2.59
8.38
2.70
9.73
2.84
10.64 2.93
11.77 3.05
5.14
2.32
6.31
2.43
7.47
2.54
8.64
2.65
10.04 2.79
10.97 2.88
12.13 2.99
5.16
2.30
6.33
2.41
7.50
2.52
8.67
2.63
10.07 2.77
11.01 2.86
12.18 2.97
5.18
2.29
6.35
2.40
7.52
2.51
8.70
2.62
10.10 2.76
11.04 2.85
12.21 2.96
5.30
2.26
6.50
2.37
7.70
2.48
8.90
2.59
10.35 2.72
11.31 2.81
12.51 2.92
5.32
2.25
6.52
2.36
7.72
2.47
8.93
2.58
10.38 2.71
11.34 2.80
12.54 2.91
5.33
2.23
6.54
2.34
7.75
2.45
8.96
2.56
10.41 2.69
11.38 2.77
12.59 2.88

133

Capacity Tables

Combination
(Capacity)
2.0+6.0+6.0

2.5+2.5+2.5

2.5+2.5+3.5

2.5+2.5+5.0

2.5+2.5+6.0

2.5+2.5+7.1

2.5+3.5+3.5

2.5+3.5+5.0

2.5+3.5+6.0

134

EDAU12-722

Outdoor
air temp.
CWB
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0

16C
TC
PI
kW
kW
5.93
2.14
7.14
2.24
8.35
2.35
9.55
2.46
11.01 2.59
11.97 2.68
13.18 2.79
5.28
2.22
6.36
2.33
7.44
2.44
8.52
2.56
9.81
2.69
10.68 2.78
11.75 2.89
5.41
2.26
6.52
2.37
7.62
2.49
8.72
2.60
10.05 2.74
10.93 2.83
12.04 2.95
5.71
2.22
6.88
2.33
8.04
2.44
9.21
2.56
10.60 2.69
11.54 2.78
12.70 2.89
5.73
2.20
6.90
2.31
8.06
2.42
9.23
2.54
10.64 2.67
11.57 2.76
12.74 2.87
5.75
2.19
6.92
2.30
8.10
2.42
9.27
2.53
10.68 2.66
11.62 2.75
12.79 2.86
5.54
2.26
6.67
2.37
7.80
2.49
8.93
2.60
10.29 2.74
11.19 2.83
12.32 2.95
5.71
2.22
6.88
2.33
8.04
2.44
9.21
2.56
10.60 2.69
11.54 2.78
12.70 2.89
5.73
2.20
6.90
2.31
8.07
2.42
9.24
2.54
10.65 2.67
11.58 2.76
12.75 2.87

18C
TC
PI
kW
kW
5.78
2.16
6.99
2.27
8.20
2.38
9.41
2.49
10.86 2.62
11.83 2.70
13.03 2.81
5.15
2.24
6.23
2.35
7.31
2.47
8.39
2.58
9.68
2.72
10.54 2.81
11.62 2.92
5.28
2.28
6.38
2.40
7.49
2.51
8.59
2.63
9.92
2.76
10.80 2.86
11.90 2.97
5.57
2.24
6.73
2.35
7.90
2.47
9.06
2.58
10.46 2.72
11.39 2.81
12.56 2.92
5.58
2.23
6.75
2.34
7.92
2.45
9.09
2.56
10.49 2.70
11.43 2.79
12.60 2.90
5.61
2.22
6.78
2.33
7.95
2.44
9.13
2.55
10.53 2.69
11.47 2.77
12.65 2.89
5.40
2.28
6.53
2.40
7.66
2.51
8.79
2.63
10.15 2.76
11.05 2.86
12.18 2.97
5.57
2.24
6.73
2.35
7.90
2.47
9.06
2.58
10.46 2.72
11.39 2.81
12.56 2.92
5.59
2.23
6.76
2.34
7.93
2.45
9.10
2.56
10.50 2.70
11.44 2.79
12.61 2.90

Indoor air temp.:CDB


20C
21C
TC
PI
TC
PI
kW
kW
kW
kW
5.63
2.18
5.56
2.20
6.84
2.29
6.77
2.30
8.05
2.40
7.98
2.41
9.26
2.51
9.18
2.52
10.71 2.64 10.64 2.65
11.68 2.73 11.60 2.74
12.89 2.84 12.81 2.85
5.02
2.27
4.95
2.28
6.10
2.38
6.03
2.39
7.18
2.49
7.11
2.50
8.26
2.60
8.19
2.62
9.55
2.74
9.48
2.75
10.41 2.83 10.35 2.84
11.49 2.94 11.43 2.96
5.14
2.31
5.07
2.32
6.25
2.42
6.18
2.43
7.35
2.54
7.28
2.55
8.45
2.65
8.39
2.66
9.78
2.79
9.71
2.80
10.66 2.88 10.60 2.89
11.77 3.00 11.70 3.01
5.43
2.27
5.35
2.28
6.59
2.38
6.52
2.39
7.76
2.49
7.69
2.50
8.92
2.60
8.85
2.62
10.32 2.74 10.25 2.75
11.25 2.83 11.18 2.84
12.42 2.94 12.35 2.96
5.44
2.25
5.37
2.26
6.61
2.36
6.54
2.37
7.78
2.47
7.71
2.49
8.95
2.59
8.88
2.60
10.35 2.72 10.28 2.73
11.28 2.81 11.21 2.82
12.45 2.92 12.38 2.93
5.46
2.24
5.39
2.25
6.64
2.35
6.56
2.37
7.81
2.46
7.74
2.48
8.98
2.58
8.91
2.59
10.39 2.71 10.32 2.72
11.33 2.80 11.26 2.81
12.50 2.91 12.43 2.92
5.26
2.31
5.19
2.32
6.39
2.42
6.32
2.43
7.52
2.54
7.45
2.55
8.65
2.65
8.58
2.66
10.01 2.79
9.94
2.80
10.91 2.88 10.85 2.89
12.04 3.00 11.98 3.01
5.43
2.27
5.35
2.28
6.59
2.38
6.52
2.39
7.76
2.49
7.69
2.50
8.92
2.60
8.85
2.62
10.32 2.74 10.25 2.75
11.25 2.83 11.18 2.84
12.42 2.94 12.35 2.96
5.45
2.25
5.38
2.26
6.62
2.36
6.55
2.37
7.79
2.47
7.71
2.49
8.96
2.59
8.88
2.60
10.36 2.72 10.29 2.73
11.30 2.81 11.22 2.82
12.47 2.92 12.39 2.93

22C
TC
PI
kW
kW
5.48
2.21
6.69
2.32
7.90
2.42
9.11
2.53
10.56 2.66
11.53 2.75
12.74 2.86
4.89
2.29
5.97
2.40
7.05
2.52
8.12
2.63
9.42
2.76
10.28 2.85
11.36 2.97
5.01
2.33
6.11
2.45
7.22
2.56
8.32
2.68
9.64
2.82
10.53 2.91
11.63 3.02
5.28
2.29
6.45
2.40
7.61
2.52
8.78
2.63
10.18 2.76
11.11 2.85
12.28 2.97
5.30
2.27
6.47
2.39
7.64
2.50
8.80
2.61
10.21 2.74
11.14 2.83
12.31 2.95
5.32
2.27
6.49
2.38
7.67
2.49
8.84
2.60
10.25 2.73
11.19 2.82
12.36 2.94
5.12
2.33
6.25
2.45
7.39
2.56
8.52
2.68
9.87
2.82
10.78 2.91
11.91 3.02
5.28
2.29
6.45
2.40
7.61
2.52
8.78
2.63
10.18 2.76
11.11 2.85
12.28 2.97
5.30
2.27
6.47
2.39
7.64
2.50
8.81
2.61
10.22 2.74
11.15 2.83
12.32 2.95

24C
TC
PI
kW
kW
5.33
2.23
6.54
2.34
7.75
2.45
8.96
2.56
10.41 2.69
11.38 2.77
12.59 2.88
4.76
2.32
5.84
2.43
6.91
2.54
7.99
2.65
9.29
2.79
10.15 2.88
11.23 2.99
4.87
2.36
5.98
2.47
7.08
2.59
8.18
2.70
9.51
2.84
10.39 2.93
11.50 3.05
5.14
2.32
6.31
2.43
7.47
2.54
8.64
2.65
10.04 2.79
10.97 2.88
12.13 2.99
5.16
2.30
6.32
2.41
7.49
2.52
8.66
2.63
10.06 2.77
11.00 2.86
12.17 2.97
5.18
2.29
6.35
2.40
7.52
2.51
8.70
2.62
10.10 2.76
11.04 2.85
12.21 2.96
4.99
2.36
6.12
2.47
7.25
2.59
8.38
2.70
9.73
2.84
10.64 2.93
11.77 3.05
5.14
2.32
6.31
2.43
7.47
2.54
8.64
2.65
10.04 2.79
10.97 2.88
12.13 2.99
5.16
2.30
6.33
2.41
7.50
2.52
8.67
2.63
10.07 2.77
11.01 2.86
12.18 2.97

SUPER MULTI NX E-Series Heat Pump

EDAU12-722

Combination
(Capacity)
2.5+3.5+7.1

2.5+5.0+5.0

2.5+5.0+6.0

2.5+6.0+6.0

3.5+3.5+3.5

3.5+3.5+5.0

3.5+3.5+6.0

3.5+3.5+7.1

3.5+5.0+5.0

Capacity Tables

Outdoor
air temp.
CWB
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0

SUPER MULTI NX E-Series Heat Pump

16C
TC
PI
kW
kW
5.75
2.19
6.92
2.30
8.10
2.42
9.27
2.53
10.68 2.66
11.62 2.75
12.79 2.86
5.89
2.16
7.09
2.27
8.29
2.38
9.49
2.49
10.93 2.62
11.89 2.71
13.10 2.82
5.90
2.15
7.11
2.26
8.31
2.37
9.52
2.48
10.96 2.61
11.93 2.70
13.13 2.81
5.93
2.14
7.14
2.24
8.35
2.35
9.55
2.46
11.01 2.59
11.97 2.68
13.18 2.79
5.54
2.26
6.68
2.37
7.81
2.49
8.94
2.60
10.30 2.74
11.20 2.83
12.33 2.95
5.72
2.21
6.88
2.32
8.05
2.43
9.22
2.55
10.62 2.68
11.55 2.77
12.71 2.88
5.74
2.20
6.91
2.31
8.08
2.42
9.25
2.54
10.66 2.67
11.59 2.76
12.76 2.87
5.75
2.19
6.93
2.30
8.10
2.42
9.28
2.53
10.69 2.66
11.63 2.75
12.80 2.86
5.89
2.16
7.09
2.27
8.29
2.38
9.49
2.49
10.93 2.62
11.89 2.71
13.10 2.82

18C
TC
PI
kW
kW
5.61
2.22
6.78
2.33
7.95
2.44
9.13
2.55
10.53 2.69
11.47 2.77
12.65 2.89
5.74
2.18
6.94
2.29
8.14
2.40
9.35
2.51
10.79 2.65
11.75 2.73
12.95 2.84
5.76
2.18
6.96
2.29
8.17
2.40
9.37
2.50
10.82 2.64
11.78 2.72
12.99 2.83
5.78
2.16
6.99
2.27
8.20
2.38
9.41
2.49
10.86 2.62
11.83 2.70
13.03 2.81
5.41
2.28
6.54
2.40
7.67
2.51
8.80
2.63
10.16 2.76
11.06 2.86
12.19 2.97
5.57
2.23
6.74
2.35
7.91
2.46
9.07
2.57
10.47 2.71
11.41 2.80
12.57 2.91
5.60
2.23
6.77
2.34
7.94
2.45
9.11
2.56
10.51 2.70
11.45 2.79
12.62 2.90
5.61
2.22
6.79
2.33
7.96
2.44
9.13
2.55
10.54 2.69
11.48 2.77
12.66 2.89
5.74
2.18
6.94
2.29
8.14
2.40
9.35
2.51
10.79 2.65
11.75 2.73
12.95 2.84

Indoor air temp.:CDB


20C
21C
TC
PI
TC
PI
kW
kW
kW
kW
5.46
2.24
5.39
2.25
6.64
2.35
6.56
2.37
7.81
2.46
7.74
2.48
8.98
2.58
8.91
2.59
10.39 2.71 10.32 2.72
11.33 2.80 11.26 2.81
12.50 2.91 12.43 2.92
5.59
2.21
5.52
2.22
6.80
2.32
6.72
2.33
8.00
2.43
7.92
2.44
9.20
2.54
9.12
2.55
10.64 2.67 10.57 2.68
11.60 2.76 11.53 2.77
12.80 2.87 12.73 2.88
5.61
2.20
5.54
2.21
6.81
2.31
6.74
2.32
8.02
2.42
7.95
2.43
9.22
2.53
9.15
2.54
10.67 2.66 10.60 2.67
11.63 2.75 11.56 2.76
12.84 2.86 12.77 2.87
5.63
2.18
5.56
2.20
6.84
2.29
6.77
2.30
8.05
2.40
7.98
2.41
9.26
2.51
9.18
2.52
10.71 2.64 10.64 2.65
11.68 2.73 11.60 2.74
12.89 2.84 12.81 2.85
5.27
2.31
5.20
2.32
6.40
2.42
6.33
2.43
7.53
2.54
7.46
2.55
8.66
2.65
8.59
2.66
10.02 2.79
9.95
2.80
10.93 2.88 10.86 2.89
12.06 3.00 11.99 3.01
5.43
2.26
5.36
2.27
6.60
2.37
6.53
2.38
7.76
2.48
7.69
2.49
8.93
2.60
8.86
2.61
10.33 2.73 10.26 2.74
11.26 2.82 11.19 2.83
12.43 2.93 12.36 2.94
5.45
2.25
5.38
2.26
6.62
2.36
6.55
2.37
7.79
2.47
7.72
2.49
8.96
2.59
8.89
2.60
10.37 2.72 10.30 2.73
11.31 2.81 11.24 2.82
12.48 2.92 12.41 2.93
5.47
2.24
5.40
2.25
6.64
2.35
6.57
2.37
7.82
2.46
7.74
2.48
8.99
2.58
8.92
2.59
10.40 2.71 10.33 2.72
11.34 2.80 11.27 2.81
12.51 2.91 12.44 2.92
5.59
2.21
5.52
2.22
6.80
2.32
6.72
2.33
8.00
2.43
7.92
2.44
9.20
2.54
9.12
2.55
10.64 2.67 10.57 2.68
11.60 2.76 11.53 2.77
12.80 2.87 12.73 2.88

22C
TC
PI
kW
kW
5.32
2.27
6.49
2.38
7.67
2.49
8.84
2.60
10.25 2.73
11.19 2.82
12.36 2.94
5.45
2.23
6.65
2.34
7.85
2.45
9.05
2.56
10.49 2.69
11.45 2.78
12.66 2.89
5.46
2.22
6.67
2.33
7.87
2.44
9.08
2.55
10.52 2.68
11.49 2.77
12.69 2.88
5.48
2.21
6.69
2.32
7.90
2.42
9.11
2.53
10.56 2.66
11.53 2.75
12.74 2.86
5.13
2.33
6.26
2.45
7.39
2.56
8.52
2.68
9.88
2.82
10.79 2.91
11.92 3.02
5.29
2.28
6.45
2.39
7.62
2.51
8.79
2.62
10.19 2.75
11.12 2.84
12.29 2.96
5.31
2.27
6.48
2.39
7.65
2.50
8.82
2.61
10.23 2.74
11.16 2.83
12.33 2.95
5.32
2.27
6.50
2.38
7.67
2.49
8.85
2.60
10.26 2.73
11.20 2.82
12.37 2.94
5.45
2.23
6.65
2.34
7.85
2.45
9.05
2.56
10.49 2.69
11.45 2.78
12.66 2.89

24C
TC
PI
kW
kW
5.18
2.29
6.35
2.40
7.52
2.51
8.70
2.62
10.10 2.76
11.04 2.85
12.21 2.96
5.30
2.26
6.50
2.37
7.70
2.48
8.90
2.59
10.35 2.72
11.31 2.81
12.51 2.92
5.32
2.25
6.52
2.36
7.72
2.47
8.93
2.58
10.38 2.71
11.34 2.80
12.54 2.91
5.33
2.23
6.54
2.34
7.75
2.45
8.96
2.56
10.41 2.69
11.38 2.77
12.59 2.88
4.99
2.36
6.12
2.47
7.25
2.59
8.39
2.70
9.74
2.84
10.65 2.93
11.78 3.05
5.15
2.31
6.31
2.42
7.48
2.53
8.65
2.64
10.04 2.78
10.98 2.87
12.14 2.98
5.17
2.30
6.34
2.41
7.51
2.52
8.68
2.63
10.08 2.77
11.02 2.86
12.19 2.97
5.18
2.29
6.35
2.40
7.53
2.51
8.70
2.62
10.11 2.76
11.05 2.85
12.23 2.96
5.30
2.26
6.50
2.37
7.70
2.48
8.90
2.59
10.35 2.72
11.31 2.81
12.51 2.92

135

Capacity Tables

Combination
(Capacity)
3.5+5.0+6.0

2.0+2.0+2.0+2.0

2.0+2.0+2.0+2.5

2.0+2.0+2.0+3.5

2.0+2.0+2.0+5.0

2.0+2.0+2.0+6.0

2.0+2.0+2.0+7.1

2.0+2.0+2.5+2.5

2.0+2.0+2.5+3.5

136

EDAU12-722

Outdoor
air temp.
CWB
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0

16C
TC
PI
kW
kW
5.91
2.14
7.12
2.25
8.32
2.36
9.53
2.47
10.97 2.60
11.94 2.69
13.15 2.80
5.23
2.03
6.30
2.13
7.36
2.24
8.43
2.34
9.71
2.46
10.56 2.55
11.63 2.65
5.31
2.03
6.40
2.13
7.48
2.24
8.56
2.34
9.87
2.46
10.73 2.55
11.82 2.65
5.74
2.20
6.91
2.31
8.08
2.42
9.25
2.54
10.66 2.67
11.59 2.76
12.76 2.87
5.91
2.14
7.12
2.25
8.32
2.36
9.53
2.47
10.97 2.60
11.94 2.69
13.15 2.80
5.93
2.14
7.14
2.24
8.35
2.35
9.56
2.46
11.02 2.59
11.98 2.68
13.19 2.79
5.95
2.13
7.16
2.24
8.38
2.34
9.59
2.45
11.05 2.58
12.02 2.67
13.23 2.78
5.73
2.20
6.90
2.31
8.07
2.42
9.24
2.54
10.65 2.67
11.58 2.76
12.75 2.87
5.74
2.20
6.91
2.31
8.08
2.42
9.25
2.54
10.66 2.67
11.59 2.76
12.76 2.87

18C
TC
PI
kW
kW
5.76
2.17
6.97
2.28
8.17
2.39
9.38
2.50
10.83 2.63
11.79 2.71
13.00 2.82
5.10
2.05
6.17
2.16
7.23
2.26
8.30
2.36
9.58
2.49
10.43 2.57
11.50 2.67
5.18
2.05
6.26
2.16
7.35
2.26
8.43
2.36
9.73
2.49
10.60 2.57
11.68 2.67
5.60
2.23
6.77
2.34
7.94
2.45
9.11
2.56
10.51 2.70
11.45 2.79
12.62 2.90
5.76
2.17
6.97
2.28
8.17
2.39
9.38
2.50
10.83 2.63
11.79 2.71
13.00 2.82
5.78
2.16
6.99
2.27
8.20
2.38
9.42
2.49
10.87 2.62
11.84 2.70
13.05 2.81
5.80
2.15
7.01
2.26
8.23
2.37
9.44
2.48
10.90 2.61
11.87 2.69
13.08 2.80
5.59
2.23
6.76
2.34
7.93
2.45
9.10
2.56
10.50 2.70
11.44 2.79
12.61 2.90
5.60
2.23
6.77
2.34
7.94
2.45
9.11
2.56
10.51 2.70
11.45 2.79
12.62 2.90

Indoor air temp.:CDB


20C
21C
TC
PI
TC
PI
kW
kW
kW
kW
5.61
2.19
5.54
2.20
6.82
2.30
6.75
2.31
8.03
2.41
7.95
2.42
9.23
2.52
9.16
2.53
10.68 2.65 10.61 2.66
11.64 2.74 11.57 2.75
12.85 2.85 12.78 2.86
4.97
2.08
4.90
2.09
6.04
2.18
5.97
2.19
7.10
2.28
7.04
2.29
8.17
2.39
8.10
2.40
9.45
2.51
9.38
2.52
10.30 2.59 10.24 2.60
11.37 2.70 11.31 2.71
5.05
2.08
4.98
2.09
6.13
2.18
6.06
2.19
7.22
2.28
7.15
2.29
8.30
2.39
8.23
2.40
9.60
2.51
9.53
2.52
10.47 2.59 10.40 2.60
11.55 2.70 11.48 2.71
5.45
2.25
5.38
2.26
6.62
2.36
6.55
2.37
7.79
2.47
7.72
2.49
8.96
2.59
8.89
2.60
10.37 2.72 10.30 2.73
11.31 2.81 11.24 2.82
12.48 2.92 12.41 2.93
5.61
2.19
5.54
2.20
6.82
2.30
6.75
2.31
8.03
2.41
7.95
2.42
9.23
2.52
9.16
2.53
10.68 2.65 10.61 2.66
11.64 2.74 11.57 2.75
12.85 2.85 12.78 2.86
5.64
2.18
5.56
2.20
6.85
2.29
6.77
2.30
8.06
2.40
7.98
2.41
9.27
2.51
9.19
2.52
10.72 2.64 10.65 2.65
11.69 2.73 11.61 2.74
12.90 2.84 12.82 2.85
5.65
2.18
5.58
2.19
6.87
2.28
6.79
2.30
8.08
2.39
8.01
2.40
9.29
2.50
9.22
2.51
10.75 2.63 10.68 2.64
11.72 2.72 11.65 2.73
12.93 2.82 12.86 2.84
5.45
2.25
5.38
2.26
6.62
2.36
6.55
2.37
7.79
2.47
7.71
2.49
8.96
2.59
8.88
2.60
10.36 2.72 10.29 2.73
11.30 2.81 11.22 2.82
12.47 2.92 12.39 2.93
5.45
2.25
5.38
2.26
6.62
2.36
6.55
2.37
7.79
2.47
7.72
2.49
8.96
2.59
8.89
2.60
10.37 2.72 10.30 2.73
11.31 2.81 11.24 2.82
12.48 2.92 12.41 2.93

22C
TC
PI
kW
kW
5.47
2.22
6.67
2.32
7.88
2.43
9.09
2.54
10.53 2.67
11.50 2.76
12.70 2.87
4.84
2.10
5.90
2.20
6.97
2.31
8.04
2.41
9.32
2.53
10.17 2.62
11.24 2.72
4.91
2.10
6.00
2.20
7.08
2.31
8.17
2.41
9.47
2.53
10.33 2.62
11.42 2.72
5.31
2.27
6.48
2.39
7.65
2.50
8.82
2.61
10.23 2.74
11.16 2.83
12.33 2.95
5.47
2.22
6.67
2.32
7.88
2.43
9.09
2.54
10.53 2.67
11.50 2.76
12.70 2.87
5.49
2.21
6.70
2.32
7.91
2.42
9.12
2.53
10.57 2.66
11.54 2.75
12.75 2.86
5.50
2.20
6.72
2.31
7.93
2.42
9.14
2.52
10.60 2.65
11.57 2.74
12.79 2.85
5.30
2.27
6.47
2.39
7.64
2.50
8.81
2.61
10.22 2.74
11.15 2.83
12.32 2.95
5.31
2.27
6.48
2.39
7.65
2.50
8.82
2.61
10.23 2.74
11.16 2.83
12.33 2.95

24C
TC
PI
kW
kW
5.32
2.24
6.53
2.35
7.73
2.46
8.94
2.57
10.39 2.70
11.35 2.79
12.56 2.89
4.71
2.12
5.77
2.22
6.84
2.33
7.91
2.43
9.19
2.56
10.04 2.64
11.11 2.74
4.78
2.12
5.87
2.22
6.95
2.33
8.03
2.43
9.33
2.56
10.20 2.64
11.29 2.74
5.17
2.30
6.34
2.41
7.51
2.52
8.68
2.63
10.08 2.77
11.02 2.86
12.19 2.97
5.32
2.24
6.53
2.35
7.73
2.46
8.94
2.57
10.39 2.70
11.35 2.79
12.56 2.89
5.34
2.23
6.55
2.34
7.76
2.45
8.97
2.56
10.42 2.69
11.39 2.77
12.60 2.88
5.35
2.22
6.57
2.33
7.78
2.44
9.00
2.55
10.45 2.68
11.42 2.76
12.64 2.87
5.16
2.30
6.33
2.41
7.50
2.52
8.67
2.63
10.07 2.77
11.01 2.86
12.18 2.97
5.17
2.30
6.34
2.41
7.51
2.52
8.68
2.63
10.08 2.77
11.02 2.86
12.19 2.97

SUPER MULTI NX E-Series Heat Pump

EDAU12-722

Combination
(Capacity)
2.0+2.0+2.5+5.0

2.0+2.0+2.5+6.0

2.0+2.0+2.5+7.1

2.0+2.0+3.5+3.5

2.0+2.0+3.5+5.0

2.0+2.0+3.5+6.0

2.0+2.0+5.0+5.0

2.0+2.5+2.5+2.5

2.0+2.5+2.5+3.5

Capacity Tables

Outdoor
air temp.
CWB
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0

SUPER MULTI NX E-Series Heat Pump

16C
TC
PI
kW
kW
5.91
2.14
7.12
2.25
8.32
2.36
9.53
2.47
10.97 2.60
11.94 2.69
13.15 2.80
5.93
2.14
7.14
2.24
8.35
2.35
9.56
2.46
11.02 2.59
11.98 2.68
13.19 2.79
5.95
2.13
7.16
2.24
8.38
2.34
9.59
2.45
11.05 2.58
12.02 2.67
13.23 2.78
5.74
2.20
6.92
2.31
8.09
2.42
9.26
2.54
10.67 2.67
11.60 2.76
12.78 2.87
5.92
2.14
7.12
2.25
8.33
2.36
9.54
2.47
10.99 2.60
11.95 2.69
13.16 2.80
5.94
2.14
7.15
2.24
8.36
2.35
9.57
2.46
11.03 2.59
12.00 2.68
13.21 2.79
6.09
2.10
7.33
2.20
8.57
2.31
9.81
2.42
11.30 2.54
12.30 2.63
13.54 2.74
5.73
2.20
6.90
2.31
8.07
2.42
9.24
2.54
10.65 2.67
11.58 2.76
12.75 2.87
5.74
2.20
6.91
2.31
8.08
2.42
9.25
2.54
10.66 2.67
11.59 2.76
12.76 2.87

18C
TC
PI
kW
kW
5.76
2.17
6.97
2.28
8.17
2.39
9.38
2.50
10.83 2.63
11.79 2.71
13.00 2.82
5.78
2.16
6.99
2.27
8.20
2.38
9.42
2.49
10.87 2.62
11.84 2.70
13.05 2.81
5.80
2.15
7.01
2.26
8.23
2.37
9.44
2.48
10.90 2.61
11.87 2.69
13.08 2.80
5.60
2.23
6.77
2.34
7.94
2.45
9.12
2.56
10.52 2.70
11.46 2.79
12.63 2.90
5.77
2.17
6.97
2.28
8.18
2.39
9.39
2.50
10.84 2.63
11.80 2.71
13.01 2.82
5.79
2.16
7.00
2.27
8.21
2.38
9.42
2.49
10.88 2.62
11.85 2.70
13.06 2.81
5.94
2.12
7.18
2.23
8.42
2.33
9.66
2.44
11.15 2.57
12.15 2.65
13.39 2.76
5.59
2.23
6.76
2.34
7.93
2.45
9.10
2.56
10.50 2.70
11.44 2.79
12.61 2.90
5.60
2.23
6.77
2.34
7.94
2.45
9.11
2.56
10.51 2.70
11.45 2.79
12.62 2.90

Indoor air temp.:CDB


20C
21C
TC
PI
TC
PI
kW
kW
kW
kW
5.61
2.19
5.54
2.20
6.82
2.30
6.75
2.31
8.03
2.41
7.95
2.42
9.23
2.52
9.16
2.53
10.68 2.65 10.61 2.66
11.64 2.74 11.57 2.75
12.85 2.85 12.78 2.86
5.64
2.18
5.56
2.20
6.85
2.29
6.77
2.30
8.06
2.40
7.98
2.41
9.27
2.51
9.19
2.52
10.72 2.64 10.65 2.65
11.69 2.73 11.61 2.74
12.90 2.84 12.82 2.85
5.65
2.18
5.58
2.19
6.87
2.28
6.79
2.30
8.08
2.39
8.01
2.40
9.29
2.50
9.22
2.51
10.75 2.63 10.68 2.64
11.72 2.72 11.65 2.73
12.93 2.82 12.86 2.84
5.46
2.25
5.39
2.26
6.63
2.36
6.56
2.37
7.80
2.47
7.73
2.49
8.97
2.59
8.90
2.60
10.38 2.72 10.31 2.73
11.32 2.81 11.25 2.82
12.49 2.92 12.42 2.93
5.62
2.19
5.55
2.20
6.83
2.30
6.75
2.31
8.03
2.41
7.96
2.42
9.24
2.52
9.17
2.53
10.69 2.65 10.62 2.66
11.66 2.74 11.58 2.75
12.86 2.85 12.79 2.86
5.64
2.18
5.57
2.20
6.85
2.29
6.78
2.30
8.06
2.40
7.99
2.41
9.28
2.51
9.20
2.52
10.73 2.64 10.66 2.65
11.70 2.73 11.63 2.74
12.91 2.84 12.84 2.85
5.78
2.14
5.71
2.15
7.03
2.25
6.95
2.26
8.27
2.36
8.19
2.37
9.51
2.46
9.43
2.47
11.00 2.59 10.92 2.60
11.99 2.68 11.92 2.69
13.24 2.78 13.16 2.79
5.45
2.25
5.38
2.26
6.62
2.36
6.55
2.37
7.79
2.47
7.71
2.49
8.96
2.59
8.88
2.60
10.36 2.72 10.29 2.73
11.30 2.81 11.22 2.82
12.47 2.92 12.39 2.93
5.45
2.25
5.38
2.26
6.62
2.36
6.55
2.37
7.79
2.47
7.72
2.49
8.96
2.59
8.89
2.60
10.37 2.72 10.30 2.73
11.31 2.81 11.24 2.82
12.48 2.92 12.41 2.93

22C
TC
PI
kW
kW
5.47
2.22
6.67
2.32
7.88
2.43
9.09
2.54
10.53 2.67
11.50 2.76
12.70 2.87
5.49
2.21
6.70
2.32
7.91
2.42
9.12
2.53
10.57 2.66
11.54 2.75
12.75 2.86
5.50
2.20
6.72
2.31
7.93
2.42
9.14
2.52
10.60 2.65
11.57 2.74
12.79 2.85
5.31
2.27
6.49
2.39
7.66
2.50
8.83
2.61
10.24 2.74
11.17 2.83
12.35 2.95
5.47
2.22
6.68
2.32
7.89
2.43
9.09
2.54
10.54 2.67
11.51 2.76
12.72 2.87
5.49
2.21
6.70
2.32
7.92
2.42
9.13
2.53
10.58 2.66
11.55 2.75
12.76 2.86
5.63
2.17
6.87
2.27
8.12
2.38
9.36
2.49
10.85 2.61
11.84 2.70
13.08 2.81
5.30
2.27
6.47
2.39
7.64
2.50
8.81
2.61
10.22 2.74
11.15 2.83
12.32 2.95
5.31
2.27
6.48
2.39
7.65
2.50
8.82
2.61
10.23 2.74
11.16 2.83
12.33 2.95

24C
TC
PI
kW
kW
5.32
2.24
6.53
2.35
7.73
2.46
8.94
2.57
10.39 2.70
11.35 2.79
12.56 2.89
5.34
2.23
6.55
2.34
7.76
2.45
8.97
2.56
10.42 2.69
11.39 2.77
12.60 2.88
5.35
2.22
6.57
2.33
7.78
2.44
9.00
2.55
10.45 2.68
11.42 2.76
12.64 2.87
5.17
2.30
6.34
2.41
7.51
2.52
8.69
2.63
10.09 2.77
11.03 2.86
12.20 2.97
5.33
2.24
6.53
2.35
7.74
2.46
8.95
2.57
10.39 2.70
11.36 2.79
12.57 2.89
5.34
2.23
6.56
2.34
7.77
2.45
8.98
2.56
10.43 2.69
11.40 2.77
12.61 2.88
5.48
2.19
6.72
2.30
7.96
2.40
9.21
2.51
10.70 2.64
11.69 2.72
12.93 2.83
5.16
2.30
6.33
2.41
7.50
2.52
8.67
2.63
10.07 2.77
11.01 2.86
12.18 2.97
5.17
2.30
6.34
2.41
7.51
2.52
8.68
2.63
10.08 2.77
11.02 2.86
12.19 2.97

137

Capacity Tables

Combination
(Capacity)
2.0+2.5+2.5+5.0

2.0+2.5+2.5+6.0

2.0+2.5+2.5+7.1

2.0+2.5+3.5+3.5

2.0+2.5+3.5+5.0

2.0+2.5+3.5+6.0

2.0+2.5+5.0+5.0

2.0+3.5+3.5+3.5

2.0+3.5+3.5+5.0

138

EDAU12-722

Outdoor
air temp.
CWB
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0

16C
TC
PI
kW
kW
5.91
2.14
7.12
2.25
8.32
2.36
9.53
2.47
10.97 2.60
11.94 2.69
13.15 2.80
5.93
2.14
7.14
2.24
8.35
2.35
9.56
2.46
11.02 2.59
11.98 2.68
13.19 2.79
5.95
2.13
7.16
2.24
8.38
2.34
9.59
2.45
11.05 2.58
12.02 2.67
13.23 2.78
5.74
2.20
6.92
2.31
8.09
2.42
9.26
2.54
10.67 2.67
11.60 2.76
12.78 2.87
5.92
2.14
7.12
2.25
8.33
2.36
9.54
2.47
10.99 2.60
11.95 2.69
13.16 2.80
5.94
2.14
7.15
2.24
8.36
2.35
9.57
2.46
11.03 2.59
12.00 2.68
13.21 2.79
6.09
2.10
7.33
2.20
8.57
2.31
9.81
2.42
11.30 2.54
12.30 2.63
13.54 2.74
5.74
2.19
6.92
2.30
8.09
2.42
9.26
2.53
10.67 2.66
11.60 2.75
12.78 2.86
5.92
2.14
7.13
2.25
8.34
2.36
9.55
2.47
11.00 2.60
11.96 2.69
13.17 2.80

18C
TC
PI
kW
kW
5.76
2.17
6.97
2.28
8.17
2.39
9.38
2.50
10.83 2.63
11.79 2.71
13.00 2.82
5.78
2.16
6.99
2.27
8.20
2.38
9.42
2.49
10.87 2.62
11.84 2.70
13.05 2.81
5.80
2.15
7.01
2.26
8.23
2.37
9.44
2.48
10.90 2.61
11.87 2.69
13.08 2.80
5.60
2.23
6.77
2.34
7.94
2.45
9.12
2.56
10.52 2.70
11.46 2.79
12.63 2.90
5.77
2.17
6.97
2.28
8.18
2.39
9.39
2.50
10.84 2.63
11.80 2.71
13.01 2.82
5.79
2.16
7.00
2.27
8.21
2.38
9.42
2.49
10.88 2.62
11.85 2.70
13.06 2.81
5.94
2.12
7.18
2.23
8.42
2.33
9.66
2.44
11.15 2.57
12.15 2.65
13.39 2.76
5.60
2.22
6.77
2.33
7.94
2.44
9.12
2.55
10.52 2.69
11.46 2.77
12.63 2.89
5.77
2.17
6.98
2.28
8.19
2.39
9.40
2.50
10.85 2.63
11.81 2.71
13.02 2.82

Indoor air temp.:CDB


20C
21C
TC
PI
TC
PI
kW
kW
kW
kW
5.61
2.19
5.54
2.20
6.82
2.30
6.75
2.31
8.03
2.41
7.95
2.42
9.23
2.52
9.16
2.53
10.68 2.65 10.61 2.66
11.64 2.74 11.57 2.75
12.85 2.85 12.78 2.86
5.64
2.18
5.56
2.20
6.85
2.29
6.77
2.30
8.06
2.40
7.98
2.41
9.27
2.51
9.19
2.52
10.72 2.64 10.65 2.65
11.69 2.73 11.61 2.74
12.90 2.84 12.82 2.85
5.65
2.18
5.58
2.19
6.87
2.28
6.79
2.30
8.08
2.39
8.01
2.40
9.29
2.50
9.22
2.51
10.75 2.63 10.68 2.64
11.72 2.72 11.65 2.73
12.93 2.82 12.86 2.84
5.46
2.25
5.39
2.26
6.63
2.36
6.56
2.37
7.80
2.47
7.73
2.49
8.97
2.59
8.90
2.60
10.38 2.72 10.31 2.73
11.32 2.81 11.25 2.82
12.49 2.92 12.42 2.93
5.62
2.19
5.55
2.20
6.83
2.30
6.75
2.31
8.03
2.41
7.96
2.42
9.24
2.52
9.17
2.53
10.69 2.65 10.62 2.66
11.66 2.74 11.58 2.75
12.86 2.85 12.79 2.86
5.64
2.18
5.57
2.20
6.85
2.29
6.78
2.30
8.06
2.40
7.99
2.41
9.28
2.51
9.20
2.52
10.73 2.64 10.66 2.65
11.70 2.73 11.63 2.74
12.91 2.84 12.84 2.85
5.78
2.14
5.71
2.15
7.03
2.25
6.95
2.26
8.27
2.36
8.19
2.37
9.51
2.46
9.43
2.47
11.00 2.59 10.92 2.60
11.99 2.68 11.92 2.69
13.24 2.78 13.16 2.79
5.46
2.24
5.39
2.25
6.63
2.35
6.56
2.37
7.80
2.46
7.73
2.48
8.97
2.58
8.90
2.59
10.38 2.71 10.31 2.72
11.32 2.80 11.25 2.81
12.49 2.91 12.42 2.92
5.63
2.19
5.55
2.20
6.83
2.30
6.76
2.31
8.04
2.41
7.97
2.42
9.25
2.52
9.18
2.53
10.70 2.65 10.63 2.66
11.67 2.74 11.59 2.75
12.87 2.85 12.80 2.86

22C
TC
PI
kW
kW
5.47
2.22
6.67
2.32
7.88
2.43
9.09
2.54
10.53 2.67
11.50 2.76
12.70 2.87
5.49
2.21
6.70
2.32
7.91
2.42
9.12
2.53
10.57 2.66
11.54 2.75
12.75 2.86
5.50
2.20
6.72
2.31
7.93
2.42
9.14
2.52
10.60 2.65
11.57 2.74
12.79 2.85
5.31
2.27
6.49
2.39
7.66
2.50
8.83
2.61
10.24 2.74
11.17 2.83
12.35 2.95
5.47
2.22
6.68
2.32
7.89
2.43
9.09
2.54
10.54 2.67
11.51 2.76
12.72 2.87
5.49
2.21
6.70
2.32
7.92
2.42
9.13
2.53
10.58 2.66
11.55 2.75
12.76 2.86
5.63
2.17
6.87
2.27
8.12
2.38
9.36
2.49
10.85 2.61
11.84 2.70
13.08 2.81
5.31
2.27
6.49
2.38
7.66
2.49
8.83
2.60
10.24 2.73
11.17 2.82
12.35 2.94
5.48
2.22
6.69
2.32
7.89
2.43
9.10
2.54
10.55 2.67
11.52 2.76
12.73 2.87

24C
TC
PI
kW
kW
5.32
2.24
6.53
2.35
7.73
2.46
8.94
2.57
10.39 2.70
11.35 2.79
12.56 2.89
5.34
2.23
6.55
2.34
7.76
2.45
8.97
2.56
10.42 2.69
11.39 2.77
12.60 2.88
5.35
2.22
6.57
2.33
7.78
2.44
9.00
2.55
10.45 2.68
11.42 2.76
12.64 2.87
5.17
2.30
6.34
2.41
7.51
2.52
8.69
2.63
10.09 2.77
11.03 2.86
12.20 2.97
5.33
2.24
6.53
2.35
7.74
2.46
8.95
2.57
10.39 2.70
11.36 2.79
12.57 2.89
5.34
2.23
6.56
2.34
7.77
2.45
8.98
2.56
10.43 2.69
11.40 2.77
12.61 2.88
5.48
2.19
6.72
2.30
7.96
2.40
9.21
2.51
10.70 2.64
11.69 2.72
12.93 2.83
5.17
2.29
6.34
2.40
7.51
2.51
8.69
2.62
10.09 2.76
11.03 2.85
12.20 2.96
5.33
2.24
6.54
2.35
7.75
2.46
8.95
2.57
10.40 2.70
11.37 2.79
12.58 2.89

SUPER MULTI NX E-Series Heat Pump

EDAU12-722

Combination
(Capacity)
2.5+2.5+2.5+2.5

2.5+2.5+2.5+3.5

2.5+2.5+2.5+5.0

2.5+2.5+2.5+6.0

2.5+2.5+3.5+3.5

2.5+2.5+3.5+5.0

2.5+2.5+3.5+6.0

2.5+3.5+3.5+3.5

2.5+3.5+3.5+5.0

Capacity Tables

Outdoor
air temp.
CWB
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0

SUPER MULTI NX E-Series Heat Pump

16C
TC
PI
kW
kW
5.73
2.20
6.90
2.31
8.07
2.42
9.24
2.54
10.65 2.67
11.58 2.76
12.75 2.87
5.74
2.20
6.91
2.31
8.08
2.42
9.25
2.54
10.66 2.67
11.59 2.76
12.76 2.87
5.91
2.14
7.12
2.25
8.32
2.36
9.53
2.47
10.97 2.60
11.94 2.69
13.15 2.80
5.93
2.14
7.14
2.24
8.35
2.35
9.56
2.46
11.02 2.59
11.98 2.68
13.19 2.79
5.74
2.20
6.92
2.31
8.09
2.42
9.26
2.54
10.67 2.67
11.60 2.76
12.78 2.87
5.92
2.14
7.12
2.25
8.33
2.36
9.54
2.47
10.99 2.60
11.95 2.69
13.16 2.80
5.94
2.14
7.15
2.24
8.36
2.35
9.57
2.46
11.03 2.59
12.00 2.68
13.21 2.79
5.74
2.19
6.92
2.30
8.09
2.42
9.26
2.53
10.67 2.66
11.60 2.75
12.78 2.86
5.92
2.14
7.13
2.25
8.34
2.36
9.55
2.47
11.00 2.60
11.96 2.69
13.17 2.80

18C
TC
PI
kW
kW
5.59
2.23
6.76
2.34
7.93
2.45
9.10
2.56
10.50 2.70
11.44 2.79
12.61 2.90
5.60
2.23
6.77
2.34
7.94
2.45
9.11
2.56
10.51 2.70
11.45 2.79
12.62 2.90
5.76
2.17
6.97
2.28
8.17
2.39
9.38
2.50
10.83 2.63
11.79 2.71
13.00 2.82
5.78
2.16
6.99
2.27
8.20
2.38
9.42
2.49
10.87 2.62
11.84 2.70
13.05 2.81
5.60
2.23
6.77
2.34
7.94
2.45
9.12
2.56
10.52 2.70
11.46 2.79
12.63 2.90
5.77
2.17
6.97
2.28
8.18
2.39
9.39
2.50
10.84 2.63
11.80 2.71
13.01 2.82
5.79
2.16
7.00
2.27
8.21
2.38
9.42
2.49
10.88 2.62
11.85 2.70
13.06 2.81
5.60
2.22
6.77
2.33
7.94
2.44
9.12
2.55
10.52 2.69
11.46 2.77
12.63 2.89
5.77
2.17
6.98
2.28
8.19
2.39
9.40
2.50
10.85 2.63
11.81 2.71
13.02 2.82

Indoor air temp.:CDB


20C
21C
TC
PI
TC
PI
kW
kW
kW
kW
5.45
2.25
5.38
2.26
6.62
2.36
6.55
2.37
7.79
2.47
7.71
2.49
8.96
2.59
8.88
2.60
10.36 2.72 10.29 2.73
11.30 2.81 11.22 2.82
12.47 2.92 12.39 2.93
5.45
2.25
5.38
2.26
6.62
2.36
6.55
2.37
7.79
2.47
7.72
2.49
8.96
2.59
8.89
2.60
10.37 2.72 10.30 2.73
11.31 2.81 11.24 2.82
12.48 2.92 12.41 2.93
5.61
2.19
5.54
2.20
6.82
2.30
6.75
2.31
8.03
2.41
7.95
2.42
9.23
2.52
9.16
2.53
10.68 2.65 10.61 2.66
11.64 2.74 11.57 2.75
12.85 2.85 12.78 2.86
5.64
2.18
5.56
2.20
6.85
2.29
6.77
2.30
8.06
2.40
7.98
2.41
9.27
2.51
9.19
2.52
10.72 2.64 10.65 2.65
11.69 2.73 11.61 2.74
12.90 2.84 12.82 2.85
5.46
2.25
5.39
2.26
6.63
2.36
6.56
2.37
7.80
2.47
7.73
2.49
8.97
2.59
8.90
2.60
10.38 2.72 10.31 2.73
11.32 2.81 11.25 2.82
12.49 2.92 12.42 2.93
5.62
2.19
5.55
2.20
6.83
2.30
6.75
2.31
8.03
2.41
7.96
2.42
9.24
2.52
9.17
2.53
10.69 2.65 10.62 2.66
11.66 2.74 11.58 2.75
12.86 2.85 12.79 2.86
5.64
2.18
5.57
2.20
6.85
2.29
6.78
2.30
8.06
2.40
7.99
2.41
9.28
2.51
9.20
2.52
10.73 2.64 10.66 2.65
11.70 2.73 11.63 2.74
12.91 2.84 12.84 2.85
5.46
2.24
5.39
2.25
6.63
2.35
6.56
2.37
7.80
2.46
7.73
2.48
8.97
2.58
8.90
2.59
10.38 2.71 10.31 2.72
11.32 2.80 11.25 2.81
12.49 2.91 12.42 2.92
5.63
2.19
5.55
2.20
6.83
2.30
6.76
2.31
8.04
2.41
7.97
2.42
9.25
2.52
9.18
2.53
10.70 2.65 10.63 2.66
11.67 2.74 11.59 2.75
12.87 2.85 12.80 2.86

22C
TC
PI
kW
kW
5.30
2.27
6.47
2.39
7.64
2.50
8.81
2.61
10.22 2.74
11.15 2.83
12.32 2.95
5.31
2.27
6.48
2.39
7.65
2.50
8.82
2.61
10.23 2.74
11.16 2.83
12.33 2.95
5.47
2.22
6.67
2.32
7.88
2.43
9.09
2.54
10.53 2.67
11.50 2.76
12.70 2.87
5.49
2.21
6.70
2.32
7.91
2.42
9.12
2.53
10.57 2.66
11.54 2.75
12.75 2.86
5.31
2.27
6.49
2.39
7.66
2.50
8.83
2.61
10.24 2.74
11.17 2.83
12.35 2.95
5.47
2.22
6.68
2.32
7.89
2.43
9.09
2.54
10.54 2.67
11.51 2.76
12.72 2.87
5.49
2.21
6.70
2.32
7.92
2.42
9.13
2.53
10.58 2.66
11.55 2.75
12.76 2.86
5.31
2.27
6.49
2.38
7.66
2.49
8.83
2.60
10.24 2.73
11.17 2.82
12.35 2.94
5.48
2.22
6.69
2.32
7.89
2.43
9.10
2.54
10.55 2.67
11.52 2.76
12.73 2.87

24C
TC
PI
kW
kW
5.16
2.30
6.33
2.41
7.50
2.52
8.67
2.63
10.07 2.77
11.01 2.86
12.18 2.97
5.17
2.30
6.34
2.41
7.51
2.52
8.68
2.63
10.08 2.77
11.02 2.86
12.19 2.97
5.32
2.24
6.53
2.35
7.73
2.46
8.94
2.57
10.39 2.70
11.35 2.79
12.56 2.89
5.34
2.23
6.55
2.34
7.76
2.45
8.97
2.56
10.42 2.69
11.39 2.77
12.60 2.88
5.17
2.30
6.34
2.41
7.51
2.52
8.69
2.63
10.09 2.77
11.03 2.86
12.20 2.97
5.33
2.24
6.53
2.35
7.74
2.46
8.95
2.57
10.39 2.70
11.36 2.79
12.57 2.89
5.34
2.23
6.56
2.34
7.77
2.45
8.98
2.56
10.43 2.69
11.40 2.77
12.61 2.88
5.17
2.29
6.34
2.40
7.51
2.51
8.69
2.62
10.09 2.76
11.03 2.85
12.20 2.96
5.33
2.24
6.54
2.35
7.75
2.46
8.95
2.57
10.40 2.70
11.37 2.79
12.58 2.89

139

Capacity Tables

Combination
(Capacity)
3.5+3.5+3.5+3.5

EDAU12-722

Outdoor
air temp.
CWB
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0

Symbols

16C
TC
PI
kW
kW
5.75
2.19
6.92
2.30
8.10
2.42
9.27
2.53
10.68 2.66
11.62 2.75
12.79 2.86

18C
TC
PI
kW
kW
5.61
2.22
6.78
2.33
7.95
2.44
9.13
2.55
10.53 2.69
11.47 2.77
12.65 2.89

Indoor air temp.:CDB


20C
21C
TC
PI
TC
PI
kW
kW
kW
kW
5.46
2.24
5.39
2.25
6.64
2.35
6.56
2.37
7.81
2.46
7.74
2.48
8.98
2.58
8.91
2.59
10.39 2.71 10.32 2.72
11.33 2.80 11.26 2.81
12.50 2.91 12.43 2.92

22C
TC
PI
kW
kW
5.32
2.27
6.49
2.38
7.67
2.49
8.84
2.60
10.25 2.73
11.19 2.82
12.36 2.94

24C
TC
PI
kW
kW
5.18
2.29
6.35
2.40
7.52
2.51
8.70
2.62
10.10 2.76
11.04 2.85
12.21 2.96

NOTE:

TC

: Total capacity

(kW)

PI

: Power input

(kW)

Capacities are based on the following conditions.


Corresponding refrigerant piping length : 7.5m
Level difference : 0m
3D052668#1
3D052668#2
3D052668#3
3D052668#4
3D052668#5
3D052668#6
3D052668#7
3D052668#8
3D052668#9

140

SUPER MULTI NX E-Series Heat Pump

EDAU12-722

Capacity Tables

[Cooling Capacity 50Hz 240V]


Combination
(Capacity)
2.0

2.5

3.5

5.0

6.0

7.1

2.0+2.0

2.0+2.5

2.0+3.5

Outdoor
air temp.
CDB
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0

SUPER MULTI NX E-Series Heat Pump

14C
TC
PI
kW
kW
3.01
0.88
2.92
0.91
2.73
0.99
2.65
1.03
2.51
1.09
2.42
1.14
2.34
1.18
3.22
0.97
3.22
1.04
3.21
1.25
3.11
1.30
2.95
1.38
2.85
1.43
2.75
1.49
3.29
0.74
3.29
0.79
3.29
0.93
3.29
1.01
3.29
1.15
3.29
1.25
3.29
1.37
5.15
1.27
5.15
1.38
5.15
1.67
5.00
1.74
4.74
1.85
4.58
1.92
4.42
1.99
5.60
1.49
5.60
1.61
5.60
1.96
5.60
2.15
5.53
2.48
5.35
2.58
5.16
2.68
6.01
1.62
6.01
1.76
6.01
2.15
6.01
2.36
6.01
2.81
5.88
3.00
5.68
3.12
5.33
1.37
5.18
1.42
4.84
1.55
4.69
1.60
4.44
1.71
4.29
1.77
4.15
1.84
5.76
1.49
5.60
1.54
5.23
1.68
5.07
1.74
4.80
1.85
4.64
1.92
4.48
1.99
6.42
1.73
6.24
1.80
5.82
1.95
5.65
2.03
5.35
2.16
5.17
2.24
4.99
2.33

16C
TC
PI
kW
kW
3.15
0.90
3.06
0.93
2.87
1.01
2.78
1.05
2.64
1.11
2.56
1.15
2.48
1.20
3.70
1.13
3.60
1.17
3.38
1.27
3.28
1.32
3.11
1.40
3.01
1.45
2.92
1.51
4.04
0.93
4.04
1.00
4.04
1.19
4.04
1.29
4.04
1.48
4.04
1.62
4.02
1.76
5.94
1.52
5.79
1.57
5.42
1.71
5.26
1.77
5.00
1.88
4.84
1.95
4.68
2.02
6.88
2.00
6.76
2.11
6.33
2.29
6.14
2.37
5.84
2.52
5.65
2.62
5.47
2.72
7.38
2.21
7.38
2.42
6.96
2.67
6.76
2.77
6.42
2.94
6.22
3.05
6.01
3.16
5.58
1.40
5.43
1.45
5.08
1.57
4.93
1.63
4.69
1.73
4.54
1.80
4.39
1.87
6.03
1.52
5.87
1.57
5.49
1.71
5.33
1.77
5.07
1.88
4.91
1.95
4.75
2.02
6.71
1.77
6.53
1.83
6.12
1.99
5.94
2.06
5.64
2.19
5.46
2.27
5.29
2.36

Indoor air temp.:CWB


18C
19C
TC
PI
TC
PI
kW
kW
kW
kW
3.28
0.91
3.35
0.92
3.20
0.95
3.27
0.95
3.00
1.03
3.07
1.03
2.99
1.07
2.92
1.06
2.78
1.13
2.85
1.14
2.70
1.17
2.77
1.18
2.61
1.21
2.68
1.22
3.87
1.15
3.95
1.16
3.77
1.19
3.85
1.20
3.54
1.29
3.62
1.30
3.44
1.34
3.52
1.35
3.28
1.42
3.36
1.43
3.18
1.48
3.26
1.49
3.08
1.53
3.16
1.54
4.85
1.16
5.28
1.29
4.85
1.25
5.28
1.39
4.85
1.49
4.99
1.52
4.74
1.56
4.85
1.57
4.51
1.66
4.62
1.67
4.38
1.72
4.49
1.73
4.24
1.78
4.35
1.79
6.20
1.55
6.33
1.56
6.05
1.60
6.18
1.61
5.68
1.73
5.81
1.75
5.52
1.80
5.65
1.81
5.26
1.91
5.39
1.92
5.10
1.98
5.23
1.99
4.94
2.05
5.07
2.07
7.25
2.07
7.40
2.09
7.06
2.15
7.21
2.17
6.63
2.33
6.78
2.35
6.45
2.41
6.60
2.43
6.14
2.56
6.29
2.58
5.96
2.66
6.11
2.68
5.77
2.76
5.92
2.77
7.97
2.42
8.14
2.44
7.77
2.50
7.94
2.52
7.30
2.71
7.46
2.73
7.09
2.81
7.26
2.83
6.75
2.98
6.92
3.01
6.55
3.09
6.72
3.12
6.35
3.16
6.51
3.16
5.82
1.43
5.94
1.44
5.67
1.48
5.79
1.49
5.33
1.60
5.45
1.61
5.18
1.66
5.30
1.67
4.93
1.76
5.05
1.77
4.78
1.83
4.91
1.84
4.63
1.89
4.76
1.91
6.29
1.55
6.42
1.56
6.13
1.60
6.26
1.61
5.76
1.73
5.89
1.75
5.60
1.80
5.73
1.81
5.33
1.91
5.46
1.92
5.17
1.98
5.30
1.99
5.01
2.05
5.14
2.07
7.01
1.80
7.15
1.82
6.83
1.86
6.97
1.88
6.41
2.02
6.56
2.04
6.23
2.10
6.38
2.11
5.94
2.22
6.08
2.24
5.76
2.31
5.90
2.32
5.58
2.39
5.73
2.41

22C
TC
PI
kW
kW
3.56
0.95
3.48
0.98
3.28
1.06
3.20
1.10
3.06
1.16
2.97
1.20
2.89
1.25
4.19
1.20
4.09
1.24
3.86
1.34
3.76
1.38
3.60
1.47
3.50
1.52
3.40
1.57
5.77
1.39
5.64
1.44
5.32
1.55
5.19
1.61
4.96
1.71
4.82
1.77
4.69
1.83
6.72
1.60
6.57
1.66
6.20
1.79
6.04
1.86
5.78
1.97
5.62
2.04
5.46
2.11
7.86
2.15
7.67
2.22
7.24
2.41
7.06
2.49
6.75
2.64
6.56
2.73
6.38
2.83
8.64
2.51
8.44
2.59
7.96
2.80
7.76
2.90
7.42
3.07
7.22
3.18
6.99
3.16
6.31
1.48
6.16
1.53
5.81
1.65
5.67
1.71
5.42
1.81
5.27
1.88
5.12
1.95
6.82
1.60
6.66
1.66
6.29
1.79
6.13
1.86
5.86
1.97
5.70
2.04
5.54
2.11
7.59
1.87
7.42
1.93
7.00
2.09
6.82
2.16
6.52
2.29
6.35
2.37
6.17
2.46

24C
TC
PI
kW
kW
3.70
0.96
3.61
1.00
3.42
1.08
3.33
1.11
3.20
1.18
3.11
1.22
3.03
1.26
4.35
1.22
4.25
1.26
4.02
1.36
3.93
1.41
3.76
1.49
3.66
1.54
3.56
1.60
6.00
1.42
5.86
1.46
5.54
1.58
5.41
1.63
5.18
1.73
5.05
1.79
4.91
1.86
6.98
1.63
6.83
1.69
6.46
1.82
6.30
1.88
6.04
2.00
5.88
2.07
5.72
2.14
8.16
2.19
7.97
2.26
7.54
2.45
7.36
2.53
7.05
2.68
6.87
2.77
6.68
2.87
8.98
2.55
8.77
2.64
8.30
2.85
8.10
2.95
7.76
3.12
7.56
3.23
7.30
3.16
6.55
1.51
6.40
1.56
6.06
1.68
5.91
1.74
5.66
1.84
5.52
1.91
5.37
1.97
7.08
1.63
6.92
1.69
6.55
1.82
6.39
1.88
6.12
2.00
5.96
2.07
5.80
2.14
7.89
1.90
7.71
1.97
7.29
2.12
7.11
2.20
6.82
2.33
6.64
2.41
6.46
2.49

141

Capacity Tables

Combination
(Capacity)
2.0+5.0

2.0+6.0

2.0+7.1

2.5+2.5

2.5+3.5

2.5+5.0

2.5+6.0

2.5+7.1

3.5+3.5

142

EDAU12-722

Outdoor
air temp.
CDB
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0

14C
TC
PI
kW
kW
7.34
2.08
7.14
2.15
6.66
2.34
6.46
2.43
6.12
2.59
5.92
2.69
5.71
2.79
7.95
2.43
7.73
2.52
7.21
2.74
6.99
2.84
6.62
3.03
6.40
3.14
6.18
3.16
8.27
2.60
8.04
2.69
7.50
2.93
7.27
3.04
6.89
3.23
6.66
3.35
6.43
3.16
6.21
1.73
6.03
1.80
5.63
1.95
5.46
2.03
5.17
2.16
5.00
2.24
4.83
2.33
6.51
1.88
6.45
2.02
6.02
2.20
5.84
2.28
5.53
2.42
5.35
2.52
5.16
2.61
7.63
2.28
7.42
2.36
6.93
2.57
6.72
2.66
6.36
2.83
6.15
2.94
5.94
3.05
8.08
2.49
7.85
2.58
7.33
2.81
7.11
2.91
6.73
3.10
6.51
3.22
6.28
3.16
8.27
2.60
8.04
2.69
7.50
2.93
7.27
3.04
6.89
3.23
6.66
3.35
6.43
3.16
6.59
1.91
6.59
2.07
6.59
2.58
6.43
2.72
6.09
2.89
5.89
3.00
5.69
3.12

16C
TC
PI
kW
kW
7.68
2.12
7.48
2.19
7.00
2.38
6.80
2.47
6.46
2.63
6.25
2.73
6.05
2.83
8.31
2.48
8.09
2.57
7.57
2.79
7.35
2.89
6.99
3.07
6.77
3.19
6.53
3.16
8.65
2.65
8.42
2.74
7.88
2.98
7.65
3.09
7.27
3.28
7.04
3.40
6.80
3.16
6.49
1.77
6.32
1.83
5.92
1.99
5.74
2.06
5.46
2.19
5.28
2.27
5.11
2.36
6.94
1.99
6.76
2.06
6.33
2.23
6.14
2.32
5.84
2.46
5.65
2.55
5.47
2.65
7.98
2.32
7.77
2.40
7.28
2.61
7.07
2.71
6.71
2.88
6.50
2.98
6.29
3.10
8.45
2.54
8.22
2.63
7.70
2.86
7.48
2.96
7.10
3.15
6.88
3.26
6.64
3.16
8.65
2.65
8.42
2.74
7.88
2.98
7.65
3.09
7.27
3.28
7.04
3.40
6.80
3.16
7.65
2.37
7.44
2.45
6.97
2.67
6.77
2.77
6.43
2.94
6.23
3.05
6.02
3.16

Indoor air temp.:CWB


18C
19C
TC
PI
TC
PI
kW
kW
kW
kW
8.02
2.16
8.18
2.18
7.81
2.23
7.98
2.26
7.34
2.42
7.50
2.44
7.13
2.51
7.30
2.53
6.79
2.67
6.96
2.69
6.59
2.77
6.76
2.79
6.38
2.87
6.55
2.89
8.67
2.53
8.86
2.55
8.45
2.61
8.64
2.64
7.94
2.84
8.12
2.86
7.72
2.94
7.90
2.96
7.35
3.12
7.53
3.14
7.13
3.24
7.31
3.26
6.88
3.16
7.05
3.16
9.03
2.70
9.22
2.72
8.80
2.79
8.99
2.82
8.26
3.03
8.45
3.05
8.03
3.14
8.22
3.16
7.65
3.33
7.84
3.36
7.42
3.46
7.61
3.48
7.14
3.16
7.31
3.16
6.77
1.80
6.92
1.82
6.60
1.86
6.74
1.88
6.20
2.02
6.34
2.04
6.03
2.10
6.17
2.11
5.74
2.22
5.88
2.24
5.57
2.31
5.71
2.32
5.40
2.39
5.54
2.41
7.25
2.02
7.40
2.04
7.06
2.09
7.21
2.11
6.63
2.27
6.78
2.29
6.45
2.35
6.60
2.37
6.14
2.50
6.29
2.52
5.96
2.59
6.11
2.61
5.77
2.69
5.92
2.71
8.33
2.37
8.51
2.39
8.12
2.45
8.30
2.47
7.63
2.65
7.80
2.68
7.42
2.75
7.59
2.77
7.06
2.92
7.24
2.94
6.85
3.03
7.02
3.05
6.64
3.14
6.81
3.16
8.82
2.59
9.00
2.61
8.59
2.68
8.78
2.70
8.07
2.90
8.25
2.93
7.85
3.01
8.03
3.03
7.47
3.20
7.66
3.22
7.25
3.31
7.43
3.34
6.98
3.16
7.15
3.16
9.03
2.70
9.22
2.72
8.80
2.79
8.99
2.82
8.26
3.03
8.45
3.05
8.03
3.14
8.22
3.16
7.65
3.33
7.84
3.36
7.42
3.46
7.61
3.48
7.14
3.16
7.31
3.16
7.98
2.42
8.15
2.44
7.78
2.50
7.95
2.52
7.31
2.71
7.47
2.73
7.10
2.81
7.27
2.83
6.76
2.98
6.93
3.01
6.56
3.09
6.73
3.12
6.35
3.16
6.52
3.16

22C
TC
PI
kW
kW
8.69
2.24
8.48
2.32
8.01
2.51
7.80
2.59
7.46
2.75
7.26
2.85
7.06
2.95
9.40
2.62
9.18
2.71
8.67
2.93
8.45
3.03
8.08
3.22
7.86
3.33
7.55
3.16
9.78
2.80
9.55
2.89
9.02
3.13
8.79
3.24
8.41
3.43
8.18
3.56
7.81
3.16
7.34
1.87
7.17
1.93
6.77
2.09
6.60
2.16
6.31
2.29
6.14
2.37
5.96
2.46
7.86
2.10
7.67
2.17
7.24
2.35
7.06
2.43
6.75
2.57
6.56
2.67
6.38
2.76
9.03
2.45
8.82
2.54
8.33
2.74
8.11
2.84
7.76
3.01
7.55
3.12
7.31
3.16
9.56
2.68
9.33
2.77
8.81
3.00
8.58
3.11
8.21
3.29
7.99
3.41
7.65
3.16
9.78
2.80
9.55
2.89
9.02
3.13
8.79
3.24
8.41
3.43
8.18
3.56
7.81
3.16
8.65
2.51
8.45
2.59
7.98
2.80
7.77
2.90
7.43
3.07
7.23
3.18
7.00
3.16

24C
TC
PI
kW
kW
9.02
2.28
8.82
2.36
8.34
2.55
8.14
2.63
7.80
2.79
7.60
2.89
7.39
2.99
9.77
2.67
9.55
2.76
9.03
2.98
8.81
3.08
8.44
3.26
8.22
3.38
7.87
3.16
10.16 2.85
9.93
2.94
9.40
3.18
9.17
3.29
8.78
3.48
8.55
3.61
8.13
3.16
7.63
1.90
7.46
1.97
7.05
2.12
6.88
2.20
6.59
2.33
6.42
2.41
6.25
2.49
8.16
2.14
7.97
2.21
7.54
2.38
7.36
2.47
7.05
2.61
6.87
2.71
6.68
2.80
9.38
2.50
9.17
2.58
8.68
2.79
8.46
2.88
8.11
3.05
7.90
3.16
7.64
3.16
9.93
2.73
9.70
2.82
9.18
3.05
8.95
3.15
8.58
3.34
8.36
3.46
7.98
3.16
10.16 2.85
9.93
2.94
9.40
3.18
9.17
3.29
8.78
3.48
8.55
3.61
8.13
3.16
8.99
2.55
8.78
2.64
8.31
2.85
8.11
2.95
7.77
3.12
7.57
3.23
7.31
3.16

SUPER MULTI NX E-Series Heat Pump

EDAU12-722

Combination
(Capacity)
3.5+5.0

3.5+6.0

3.5+7.1

5.0+5.0

5.0+6.0

5.0+7.1

6.0+6.0

6.0+7.1

7.1+7.1

Capacity Tables

Outdoor
air temp.
CDB
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0

SUPER MULTI NX E-Series Heat Pump

14C
TC
PI
kW
kW
8.06
2.49
7.83
2.58
7.31
2.81
7.09
2.91
6.71
3.10
6.49
3.22
6.27
3.16
8.59
2.93
8.35
3.03
7.79
3.30
7.56
3.42
7.16
3.64
6.92
3.75
6.68
3.16
8.28
2.60
8.05
2.69
7.51
2.93
7.28
3.04
6.90
3.23
6.67
3.35
6.44
3.16
8.81
2.66
8.57
2.76
8.00
3.00
7.75
3.11
7.34
3.31
7.10
3.44
6.84
3.16
8.84
2.67
8.60
2.77
8.02
3.01
7.78
3.12
7.37
3.32
7.12
3.45
6.87
3.16
9.04
2.79
8.79
2.89
8.21
3.14
7.95
3.26
7.54
3.47
7.28
3.60
7.03
3.16
9.05
2.79
8.80
2.89
8.21
3.14
7.96
3.26
7.54
3.47
7.29
3.60
7.04
3.16
9.07
2.79
8.82
2.89
8.23
3.14
7.98
3.26
7.56
3.47
7.31
3.60
7.06
3.16
9.09
2.79
8.84
2.89
8.25
3.15
8.00
3.27
7.58
3.48
7.33
3.61
7.07
3.16

16C
TC
PI
kW
kW
8.43
2.54
8.20
2.63
7.68
2.86
7.46
2.96
7.08
3.15
6.86
3.26
6.62
3.16
8.98
2.98
8.75
3.09
8.19
3.35
7.95
3.48
7.55
3.70
7.31
3.75
7.07
3.16
8.66
2.65
8.43
2.74
7.89
2.98
7.66
3.09
7.28
3.28
7.05
3.40
6.81
3.16
9.22
2.71
8.97
2.81
8.40
3.05
8.15
3.17
7.75
3.36
7.50
3.49
7.21
3.16
9.25
2.72
9.00
2.82
8.43
3.06
8.18
3.18
7.77
3.38
7.53
3.50
7.23
3.16
9.46
2.84
9.21
2.94
8.62
3.19
8.37
3.31
7.95
3.52
7.70
3.65
7.40
3.16
9.47
2.84
9.22
2.94
8.63
3.19
8.38
3.31
7.96
3.52
7.71
3.65
7.41
3.16
9.49
2.84
9.24
2.94
8.65
3.19
8.40
3.31
7.98
3.52
7.72
3.65
7.42
3.16
9.51
2.85
9.26
2.95
8.67
3.20
8.42
3.32
7.99
3.53
7.74
3.66
7.44
3.16

Indoor air temp.:CWB


18C
19C
TC
PI
TC
PI
kW
kW
kW
kW
8.80
2.59
8.98
2.61
8.57
2.68
8.76
2.70
8.05
2.90
8.23
2.93
7.83
3.01
8.01
3.03
7.45
3.20
7.64
3.22
7.23
3.31
7.41
3.34
6.97
3.16
7.14
3.16
9.38
3.04
9.57
3.07
9.14
3.14
9.34
3.17
8.58
3.41
8.78
3.44
8.34
3.54
8.54
3.56
7.95
3.75
8.14
3.78
7.71
3.75
7.90
3.75
7.47
3.16
7.67
3.16
9.04
2.70
9.23
2.72
8.81
2.79
9.00
2.82
8.27
3.03
8.46
3.05
8.04
3.14
8.23
3.16
7.66
3.33
7.85
3.36
7.43
3.46
7.62
3.48
7.15
3.16
7.32
3.16
9.62
2.77
9.82
2.79
9.37
2.86
9.58
2.89
8.80
3.10
9.00
3.13
8.56
3.22
8.76
3.24
8.15
3.42
8.35
3.44
7.91
3.54
8.11
3.57
7.56
3.16
7.74
3.16
9.65
2.77
9.85
2.80
9.41
2.87
9.61
2.90
8.83
3.11
9.04
3.14
8.59
3.23
8.79
3.25
8.18
3.43
8.38
3.45
7.93
3.55
8.14
3.58
7.59
3.16
7.76
3.16
9.87
2.89 10.08 2.92
9.62
2.99
9.83
3.02
9.03
3.25
9.24
3.28
8.78
3.37
8.99
3.39
8.36
3.57
8.57
3.60
8.11
3.71
8.32
3.73
7.76
3.16
7.94
3.16
9.88
2.89 10.09 2.92
9.63
2.99
9.84
3.02
9.04
3.25
9.25
3.28
8.79
3.37
9.00
3.39
8.37
3.57
8.58
3.60
8.12
3.71
8.33
3.73
7.77
3.16
7.94
3.16
9.90
2.89 10.11 2.92
9.65
2.99
9.86
3.02
9.06
3.25
9.27
3.28
8.81
3.37
9.02
3.39
8.39
3.57
8.60
3.60
8.14
3.71
8.35
3.73
7.78
3.16
7.96
3.16
9.93
2.90 10.13 2.93
9.67
3.00
9.88
3.03
9.08
3.26
9.29
3.29
8.83
3.38
9.04
3.40
8.41
3.59
8.62
3.61
8.16
3.72
8.37
3.74
7.80
3.16
7.97
3.16

22C
TC
PI
kW
kW
9.53
2.68
9.31
2.77
8.79
3.00
8.56
3.11
8.19
3.29
7.97
3.41
7.63
3.16
10.16 3.15
9.93
3.26
9.37
3.53
9.13
3.65
8.73
3.87
8.49
3.75
8.16
3.16
9.80
2.80
9.57
2.89
9.03
3.13
8.80
3.24
8.42
3.43
8.19
3.56
7.82
3.16
10.43 2.87
10.18 2.97
9.61
3.21
9.37
3.32
8.96
3.52
8.71
3.65
8.26
3.16
10.46 2.88
10.22 2.97
9.64
3.22
9.40
3.33
8.99
3.53
8.74
3.66
8.28
3.16
10.70 3.00
10.45 3.10
9.86
3.36
9.61
3.47
9.19
3.68
8.94
3.75
8.45
3.16
10.71 3.00
10.46 3.10
9.87
3.36
9.62
3.47
9.20
3.68
8.95
3.75
8.46
3.16
10.74 3.00
10.48 3.10
9.90
3.36
9.64
3.47
9.22
3.68
8.96
3.75
8.47
3.16
10.76 3.01
10.51 3.11
9.92
3.37
9.66
3.49
9.24
3.69
8.98
3.75
8.49
3.16

24C
TC
PI
kW
kW
9.90
2.73
9.68
2.82
9.16
3.05
8.93
3.15
8.56
3.34
8.34
3.46
7.96
3.16
10.56 3.21
10.32 3.32
9.76
3.58
9.52
3.71
9.13
3.92
8.89
3.75
8.48
3.16
10.17 2.85
9.94
2.94
9.41
3.18
9.18
3.29
8.79
3.48
8.56
3.61
8.14
3.16
10.83 2.92
10.58 3.02
10.01 3.26
9.77
3.37
9.36
3.57
9.12
3.70
8.59
3.16
10.87 2.93
10.62 3.03
10.05 3.27
9.80
3.38
9.39
3.58
9.15
3.71
8.62
3.16
11.11 3.06
10.86 3.16
10.28 3.41
10.03 3.53
9.61
3.74
9.34
3.75
8.79
3.16
11.13 3.06
10.87 3.16
10.29 3.41
10.04 3.53
9.62
3.74
9.35
3.75
8.79
3.16
11.15 3.06
10.90 3.16
10.31 3.41
10.06 3.53
9.64
3.74
9.37
3.75
8.81
3.16
11.18 3.07
10.92 3.17
10.33 3.42
10.08 3.54
9.66
3.75
9.39
3.75
8.83
3.16

143

Capacity Tables

Combination
(Capacity)
2.0+2.0+2.0

2.0+2.0+2.5

2.0+2.0+3.5

2.0+2.0+5.0

2.0+2.0+6.0

2.0+2.0+7.1

2.0+2.5+2.5

2.0+2.5+3.5

2.0+2.5+5.0

144

EDAU12-722

Outdoor
air temp.
CDB
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0

14C
TC
PI
kW
kW
6.67
1.72
6.48
1.78
6.05
1.94
5.87
2.01
5.56
2.14
5.37
2.22
5.19
2.30
6.99
1.90
6.80
1.97
6.34
2.14
6.15
2.22
5.83
2.36
5.63
2.45
5.44
2.55
7.65
2.24
7.44
2.32
6.95
2.52
6.73
2.61
6.38
2.78
6.17
2.89
5.95
3.00
8.45
2.44
8.21
2.53
7.67
2.75
7.43
2.85
7.04
3.04
6.81
3.15
6.56
3.16
8.87
2.67
8.63
2.77
8.05
3.01
7.80
3.12
7.39
3.32
7.15
3.45
6.89
3.16
9.08
2.79
8.83
2.89
8.24
3.15
7.99
3.27
7.57
3.48
7.32
3.61
7.06
3.16
7.34
2.09
7.14
2.16
6.66
2.35
6.46
2.44
6.12
2.60
5.92
2.70
5.71
2.80
7.95
2.44
7.73
2.53
7.21
2.75
6.99
2.85
6.62
3.04
6.40
3.15
6.18
3.16
8.67
2.56
8.43
2.65
7.87
2.88
7.63
2.99
7.23
3.18
6.98
3.30
6.73
3.16

16C
TC
PI
kW
kW
6.97
1.75
6.79
1.81
6.36
1.97
6.17
2.04
5.86
2.17
5.68
2.25
5.49
2.34
7.31
1.94
7.12
2.00
6.66
2.18
6.47
2.26
6.15
2.40
5.95
2.49
5.76
2.58
8.01
2.28
7.79
2.36
7.30
2.56
7.08
2.66
6.73
2.82
6.52
2.93
6.30
3.04
8.84
2.49
8.60
2.58
8.05
2.80
7.82
2.90
7.43
3.08
7.19
3.20
6.93
3.16
9.28
2.72
9.03
2.82
8.46
3.06
8.21
3.18
7.80
3.38
7.55
3.50
7.25
3.16
9.50
2.85
9.25
2.95
8.66
3.20
8.41
3.32
7.99
3.53
7.73
3.66
7.43
3.16
7.68
2.13
7.48
2.20
7.00
2.39
6.80
2.48
6.46
2.64
6.25
2.74
6.05
2.84
8.31
2.49
8.09
2.58
7.57
2.80
7.35
2.90
6.99
3.08
6.77
3.20
6.53
3.16
9.07
2.61
8.83
2.70
8.27
2.93
8.02
3.04
7.62
3.23
7.38
3.35
7.09
3.16

Indoor air temp.:CWB


18C
19C
TC
PI
TC
PI
kW
kW
kW
kW
7.28
1.78
7.43
1.80
7.09
1.85
7.25
1.86
6.66
2.00
6.82
2.02
6.48
2.08
6.63
2.09
6.17
2.20
6.32
2.22
5.98
2.29
6.14
2.30
5.80
2.37
5.95
2.39
7.63
1.97
7.79
1.99
7.44
2.04
7.60
2.06
6.98
2.21
7.14
2.23
6.79
2.29
6.95
2.31
6.47
2.44
6.63
2.45
6.27
2.53
6.43
2.54
6.08
2.62
6.24
2.64
8.36
2.32
8.53
2.34
8.14
2.40
8.32
2.42
7.65
2.61
7.82
2.63
7.43
2.70
7.61
2.72
7.08
2.87
7.26
2.89
6.87
2.97
7.04
3.00
6.66
3.08
6.83
3.11
9.22
2.54
9.42
2.56
8.99
2.62
9.18
2.65
8.44
2.85
8.63
2.87
8.21
2.95
8.40
2.97
7.82
3.13
8.01
3.16
7.58
3.25
7.77
3.27
7.29
3.16
7.47
3.16
9.68
2.77
9.89
2.80
9.44
2.87
9.64
2.90
8.86
3.11
9.07
3.14
8.62
3.23
8.82
3.25
8.21
3.43
8.41
3.45
7.96
3.55
8.16
3.58
7.61
3.16
7.79
3.16
9.92
2.90 10.12 2.93
9.66
3.00
9.87
3.03
9.07
3.26
9.28
3.29
8.82
3.38
9.03
3.40
8.40
3.59
8.61
3.61
8.15
3.72
8.36
3.74
7.79
3.16
7.97
3.16
8.02
2.17
8.18
2.19
7.81
2.24
7.98
2.26
7.34
2.43
7.50
2.45
7.13
2.52
7.30
2.54
6.79
2.68
6.96
2.70
6.59
2.78
6.76
2.80
6.38
2.88
6.55
2.90
8.67
2.54
8.86
2.56
8.45
2.62
8.64
2.65
7.94
2.85
8.12
2.87
7.72
2.95
7.90
2.97
7.35
3.13
7.53
3.16
7.13
3.25
7.31
3.27
6.88
3.16
7.05
3.16
9.47
2.66
9.66
2.68
9.22
2.75
9.42
2.77
8.66
2.98
8.86
3.01
8.42
3.09
8.62
3.11
8.02
3.28
8.22
3.30
7.78
3.40
7.98
3.43
7.45
3.16
7.63
3.16

22C
TC
PI
kW
kW
7.89
1.85
7.71
1.91
7.27
2.07
7.09
2.14
6.78
2.27
6.59
2.35
6.41
2.44
8.27
2.05
8.08
2.11
7.62
2.29
7.43
2.37
7.11
2.51
6.91
2.60
6.72
2.69
9.06
2.41
8.84
2.49
8.35
2.69
8.14
2.79
7.78
2.96
7.57
3.06
7.35
3.16
10.00 2.63
9.76
2.72
9.22
2.94
8.98
3.04
8.59
3.23
8.35
3.34
7.99
3.16
10.50 2.88
10.25 2.97
9.68
3.22
9.43
3.33
9.02
3.53
8.77
3.66
8.30
3.16
10.75 3.01
10.49 3.11
9.91
3.37
9.65
3.49
9.23
3.69
8.97
3.75
8.48
3.16
8.69
2.25
8.48
2.32
8.01
2.52
7.80
2.60
7.46
2.76
7.26
2.86
7.06
2.96
9.40
2.63
9.18
2.72
8.67
2.94
8.45
3.04
8.08
3.23
7.86
3.34
7.54
3.16
10.26 2.75
10.02 2.85
9.46
3.08
9.22
3.19
8.81
3.38
8.57
3.50
8.15
3.16

24C
TC
PI
kW
kW
8.20
1.88
8.01
1.95
7.58
2.10
7.39
2.18
7.08
2.30
6.90
2.39
6.71
2.47
8.59
2.08
8.40
2.15
7.94
2.32
7.75
2.40
7.43
2.55
7.23
2.64
7.04
2.73
9.41
2.45
9.20
2.53
8.70
2.74
8.49
2.83
8.13
3.00
7.92
3.10
7.68
3.16
10.38 2.68
10.15 2.77
9.60
2.99
9.37
3.09
8.98
3.27
8.74
3.39
8.32
3.16
10.90 2.93
10.66 3.03
10.08 3.27
9.84
3.38
9.43
3.58
9.18
3.71
8.64
3.16
11.16 3.07
10.91 3.17
10.32 3.42
10.07 3.54
9.65
3.75
9.37
3.75
8.82
3.16
9.02
2.29
8.82
2.37
8.34
2.56
8.14
2.64
7.80
2.80
7.60
2.90
7.39
3.00
9.77
2.68
9.55
2.77
9.03
2.99
8.81
3.09
8.44
3.27
8.22
3.39
7.87
3.16
10.66 2.80
10.42 2.90
9.85
3.13
9.61
3.24
9.21
3.43
8.97
3.55
8.48
3.16

SUPER MULTI NX E-Series Heat Pump

EDAU12-722

Combination
(Capacity)
2.0+2.5+6.0

2.0+2.5+7.1

2.0+3.5+3.5

2.0+3.5+5.0

2.0+3.5+6.0

2.0+3.5+7.1

2.0+5.0+5.0

2.0+5.0+6.0

2.0+5.0+7.1

Capacity Tables

Outdoor
air temp.
CDB
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0

SUPER MULTI NX E-Series Heat Pump

14C
TC
PI
kW
kW
8.89
2.67
8.65
2.77
8.07
3.01
7.82
3.12
7.41
3.32
7.16
3.45
6.90
3.16
9.08
2.79
8.83
2.89
8.24
3.15
7.99
3.27
7.57
3.48
7.32
3.61
7.06
3.16
8.28
2.60
8.05
2.69
7.51
2.93
7.28
3.04
6.90
3.23
6.67
3.35
6.44
3.16
8.86
2.67
8.62
2.77
8.04
3.01
7.80
3.12
7.39
3.32
7.14
3.45
6.88
3.16
9.07
2.79
8.82
2.89
8.23
3.14
7.98
3.26
7.56
3.47
7.31
3.60
7.06
3.16
9.12
2.79
8.87
2.89
8.28
3.15
8.03
3.27
7.60
3.48
7.35
3.61
7.10
3.16
9.45
2.74
9.18
2.83
8.57
3.08
8.31
3.20
7.87
3.40
7.61
3.53
7.29
3.16
9.60
2.86
9.33
2.96
8.71
3.22
8.44
3.34
8.00
3.56
7.73
3.69
7.43
3.16
9.66
2.87
9.39
2.97
8.76
3.23
8.49
3.35
8.05
3.57
7.78
3.70
7.47
3.16

16C
TC
PI
kW
kW
9.30
2.72
9.05
2.82
8.48
3.06
8.23
3.18
7.82
3.38
7.57
3.50
7.27
3.16
9.50
2.85
9.25
2.95
8.66
3.20
8.41
3.32
7.99
3.53
7.73
3.66
7.43
3.16
8.66
2.65
8.43
2.74
7.89
2.98
7.66
3.09
7.28
3.28
7.05
3.40
6.81
3.16
9.27
2.72
9.02
2.82
8.45
3.06
8.20
3.18
7.79
3.38
7.54
3.50
7.25
3.16
9.49
2.84
9.24
2.94
8.65
3.19
8.40
3.31
7.98
3.52
7.72
3.65
7.42
3.16
9.54
2.85
9.29
2.95
8.70
3.20
8.44
3.32
8.02
3.53
7.77
3.66
7.46
3.16
9.88
2.79
9.62
2.89
9.00
3.14
8.74
3.25
8.30
3.46
8.04
3.59
7.67
3.16
10.04 2.92
9.77
3.02
9.15
3.28
8.88
3.40
8.44
3.61
8.17
3.75
7.80
3.16
10.10 2.92
9.83
3.03
9.20
3.29
8.94
3.41
8.49
3.62
8.22
3.75
7.85
3.16

Indoor air temp.:CWB


18C
19C
TC
PI
TC
PI
kW
kW
kW
kW
9.71
2.77
9.91
2.80
9.46
2.87
9.66
2.90
8.88
3.11
9.09
3.14
8.64
3.23
8.84
3.25
8.22
3.43
8.43
3.45
7.98
3.55
8.18
3.58
7.63
3.16
7.80
3.16
9.92
2.90 10.12 2.93
9.66
3.00
9.87
3.03
9.07
3.26
9.28
3.29
8.82
3.38
9.03
3.40
8.40
3.59
8.61
3.61
8.15
3.72
8.36
3.74
7.79
3.16
7.97
3.16
9.04
2.70
9.23
2.72
8.81
2.79
9.00
2.82
8.27
3.03
8.46
3.05
8.04
3.14
8.23
3.16
7.66
3.33
7.85
3.36
7.43
3.46
7.62
3.48
7.15
3.16
7.32
3.16
9.67
2.77
9.88
2.80
9.43
2.87
9.63
2.90
8.85
3.11
9.06
3.14
8.61
3.23
8.81
3.25
8.20
3.43
8.40
3.45
7.95
3.55
8.15
3.58
7.60
3.16
7.78
3.16
9.90
2.89 10.11 2.92
9.65
2.99
9.86
3.02
9.06
3.25
9.27
3.28
8.81
3.37
9.02
3.39
8.39
3.57
8.60
3.60
8.14
3.71
8.35
3.73
7.78
3.16
7.96
3.16
9.96
2.90 10.17 2.93
9.71
3.00
9.91
3.03
9.11
3.26
9.32
3.29
8.86
3.38
9.07
3.40
8.44
3.59
8.65
3.61
8.19
3.72
8.39
3.74
7.82
3.16
8.00
3.16
10.31 2.84 10.53 2.87
10.05 2.94 10.26 2.97
9.44
3.19
9.65
3.22
9.17
3.31
9.39
3.33
8.74
3.51
8.95
3.54
8.47
3.64
8.69
3.67
8.04
3.16
8.22
3.16
10.48 2.97 10.69 3.00
10.21 3.07 10.43 3.10
9.59
3.33
9.81
3.36
9.32
3.46
9.54
3.48
8.88
3.67
9.10
3.70
8.61
3.75
8.82
3.75
8.17
3.16
8.35
3.16
10.54 2.98 10.76 3.01
10.27 3.08 10.49 3.11
9.65
3.34
9.87
3.37
9.38
3.47
9.60
3.49
8.93
3.68
9.15
3.71
8.66
3.75
8.88
3.75
8.22
3.16
8.40
3.16

22C
TC
PI
kW
kW
10.52 2.88
10.27 2.97
9.70
3.22
9.45
3.33
9.04
3.53
8.79
3.66
8.32
3.16
10.75 3.01
10.49 3.11
9.91
3.37
9.65
3.49
9.23
3.69
8.97
3.75
8.48
3.16
9.80
2.80
9.57
2.89
9.03
3.13
8.80
3.24
8.42
3.43
8.19
3.56
7.82
3.16
10.49 2.88
10.24 2.97
9.66
3.22
9.42
3.33
9.01
3.53
8.76
3.66
8.30
3.16
10.74 3.00
10.48 3.10
9.90
3.36
9.64
3.47
9.22
3.68
8.96
3.75
8.47
3.16
10.79 3.01
10.54 3.11
9.95
3.37
9.70
3.49
9.27
3.69
9.01
3.75
8.51
3.16
11.18 2.95
10.91 3.05
10.30 3.30
10.04 3.41
9.60
3.62
9.34
3.75
8.76
3.16
11.35 3.08
11.09 3.19
10.47 3.45
10.20 3.57
9.76
3.78
9.46
3.75
8.88
3.16
11.43 3.09
11.16 3.19
10.53 3.46
10.26 3.58
9.82
3.79
9.52
3.75
8.93
3.16

24C
TC
PI
kW
kW
10.93 2.93
10.68 3.03
10.11 3.27
9.86
3.38
9.45
3.58
9.20
3.71
8.66
3.16
11.16 3.07
10.91 3.17
10.32 3.42
10.07 3.54
9.65
3.75
9.37
3.75
8.82
3.16
10.17 2.85
9.94
2.94
9.41
3.18
9.18
3.29
8.79
3.48
8.56
3.61
8.14
3.16
10.89 2.93
10.65 3.03
10.07 3.27
9.82
3.38
9.41
3.58
9.17
3.71
8.63
3.16
11.15 3.06
10.90 3.16
10.31 3.41
10.06 3.53
9.64
3.74
9.37
3.75
8.81
3.16
11.21 3.07
10.96 3.17
10.37 3.42
10.11 3.54
9.69
3.75
9.42
3.75
8.85
3.16
11.61 3.00
11.35 3.10
10.73 3.35
10.47 3.47
10.03 3.67
9.76
3.75
9.11
3.16
11.79 3.14
11.53 3.24
10.91 3.50
10.64 3.62
10.19 3.84
9.87
3.75
9.23
3.16
11.87 3.15
11.60 3.25
10.97 3.51
10.71 3.63
10.26 3.85
9.93
3.75
9.28
3.16

145

Capacity Tables

Combination
(Capacity)
2.0+6.0+6.0

2.5+2.5+2.5

2.5+2.5+3.5

2.5+2.5+5.0

2.5+2.5+6.0

2.5+2.5+7.1

2.5+3.5+3.5

2.5+3.5+5.0

2.5+3.5+6.0

146

EDAU12-722

Outdoor
air temp.
CDB
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0

14C
TC
PI
kW
kW
9.66
2.87
9.39
2.97
8.76
3.23
8.49
3.35
8.05
3.57
7.78
3.70
7.47
3.16
7.65
2.24
7.44
2.32
6.95
2.52
6.73
2.61
6.38
2.78
6.17
2.89
5.95
3.00
8.10
2.49
7.87
2.58
7.35
2.81
7.12
2.91
6.75
3.10
6.52
3.22
6.30
3.16
8.85
2.66
8.61
2.76
8.03
3.00
7.79
3.11
7.38
3.31
7.13
3.44
6.87
3.16
8.89
2.67
8.65
2.77
8.07
3.01
7.82
3.12
7.41
3.32
7.16
3.45
6.90
3.16
9.08
2.79
8.83
2.89
8.24
3.15
7.99
3.27
7.57
3.48
7.32
3.61
7.06
3.16
8.39
2.54
8.16
2.63
7.61
2.86
7.38
2.97
6.99
3.16
6.76
3.28
6.52
3.16
8.86
2.67
8.62
2.77
8.04
3.01
7.80
3.12
7.39
3.32
7.14
3.45
6.88
3.16
9.07
2.79
8.82
2.89
8.23
3.14
7.98
3.26
7.56
3.47
7.31
3.60
7.06
3.16

16C
TC
PI
kW
kW
10.10 2.92
9.83
3.03
9.20
3.29
8.94
3.41
8.49
3.62
8.22
3.75
7.85
3.16
8.01
2.28
7.79
2.36
7.30
2.56
7.08
2.66
6.73
2.82
6.52
2.93
6.30
3.04
8.47
2.54
8.24
2.63
7.72
2.86
7.49
2.96
7.12
3.15
6.89
3.26
6.65
3.16
9.26
2.71
9.01
2.81
8.44
3.05
8.19
3.17
7.78
3.36
7.54
3.49
7.24
3.16
9.30
2.72
9.05
2.82
8.48
3.06
8.23
3.18
7.82
3.38
7.57
3.50
7.27
3.16
9.50
2.85
9.25
2.95
8.66
3.20
8.41
3.32
7.99
3.53
7.73
3.66
7.43
3.16
8.77
2.59
8.54
2.68
8.00
2.91
7.76
3.02
7.38
3.21
7.14
3.33
6.88
3.16
9.27
2.72
9.02
2.82
8.45
3.06
8.20
3.18
7.79
3.38
7.54
3.50
7.25
3.16
9.49
2.84
9.24
2.94
8.65
3.19
8.40
3.31
7.98
3.52
7.72
3.65
7.42
3.16

Indoor air temp.:CWB


18C
19C
TC
PI
TC
PI
kW
kW
kW
kW
10.54 2.98 10.76 3.01
10.27 3.08 10.49 3.11
9.65
3.34
9.87
3.37
9.38
3.47
9.60
3.49
8.93
3.68
9.15
3.71
8.66
3.75
8.88
3.75
8.22
3.16
8.40
3.16
8.36
2.32
8.53
2.34
8.14
2.40
8.32
2.42
7.65
2.61
7.82
2.63
7.43
2.70
7.61
2.72
7.08
2.87
7.26
2.89
6.87
2.97
7.04
3.00
6.66
3.08
6.83
3.11
8.84
2.59
9.02
2.61
8.61
2.68
8.80
2.70
8.09
2.90
8.27
2.93
7.86
3.01
8.05
3.03
7.49
3.20
7.68
3.22
7.26
3.31
7.45
3.34
7.00
3.16
7.17
3.16
9.66
2.77
9.87
2.79
9.42
2.86
9.62
2.89
8.84
3.10
9.05
3.13
8.60
3.22
8.80
3.24
8.19
3.42
8.39
3.44
7.94
3.54
8.14
3.57
7.59
3.16
7.77
3.16
9.71
2.77
9.91
2.80
9.46
2.87
9.66
2.90
8.88
3.11
9.09
3.14
8.64
3.23
8.84
3.25
8.22
3.43
8.43
3.45
7.98
3.55
8.18
3.58
7.63
3.16
7.80
3.16
9.92
2.90 10.12 2.93
9.66
3.00
9.87
3.03
9.07
3.26
9.28
3.29
8.82
3.38
9.03
3.40
8.40
3.59
8.61
3.61
8.15
3.72
8.36
3.74
7.79
3.16
7.97
3.16
9.16
2.64
9.35
2.66
8.92
2.73
9.12
2.75
8.38
2.96
8.57
2.99
8.15
3.07
8.34
3.09
7.76
3.26
7.95
3.28
7.53
3.38
7.72
3.40
7.23
3.16
7.40
3.16
9.67
2.77
9.88
2.80
9.43
2.87
9.63
2.90
8.85
3.11
9.06
3.14
8.61
3.23
8.81
3.25
8.20
3.43
8.40
3.45
7.95
3.55
8.15
3.58
7.60
3.16
7.78
3.16
9.90
2.89 10.11 2.92
9.65
2.99
9.86
3.02
9.06
3.25
9.27
3.28
8.81
3.37
9.02
3.39
8.39
3.57
8.60
3.60
8.14
3.71
8.35
3.73
7.78
3.16
7.96
3.16

22C
TC
PI
kW
kW
11.43 3.09
11.16 3.19
10.53 3.46
10.26 3.58
9.82
3.79
9.52
3.75
8.93
3.16
9.06
2.41
8.84
2.49
8.35
2.69
8.14
2.79
7.78
2.96
7.57
3.06
7.35
3.16
9.58
2.68
9.36
2.77
8.83
3.00
8.61
3.11
8.23
3.29
8.01
3.41
7.67
3.16
10.47 2.87
10.23 2.97
9.65
3.21
9.41
3.32
9.00
3.52
8.75
3.65
8.29
3.16
10.52 2.88
10.27 2.97
9.70
3.22
9.45
3.33
9.04
3.53
8.79
3.66
8.32
3.16
10.75 3.01
10.49 3.11
9.91
3.37
9.65
3.49
9.23
3.69
8.97
3.75
8.48
3.16
9.93
2.74
9.69
2.83
9.15
3.06
8.92
3.17
8.53
3.36
8.30
3.48
7.91
3.16
10.49 2.88
10.24 2.97
9.66
3.22
9.42
3.33
9.01
3.53
8.76
3.66
8.30
3.16
10.74 3.00
10.48 3.10
9.90
3.36
9.64
3.47
9.22
3.68
8.96
3.75
8.47
3.16

24C
TC
PI
kW
kW
11.87 3.15
11.60 3.25
10.97 3.51
10.71 3.63
10.26 3.85
9.93
3.75
9.28
3.16
9.41
2.45
9.20
2.53
8.70
2.74
8.49
2.83
8.13
3.00
7.92
3.10
7.68
3.16
9.95
2.73
9.73
2.82
9.20
3.05
8.98
3.15
8.60
3.34
8.38
3.46
7.99
3.16
10.88 2.92
10.63 3.02
10.06 3.26
9.81
3.37
9.40
3.57
9.16
3.70
8.62
3.16
10.93 2.93
10.68 3.03
10.11 3.27
9.86
3.38
9.45
3.58
9.20
3.71
8.66
3.16
11.16 3.07
10.91 3.17
10.32 3.42
10.07 3.54
9.65
3.75
9.37
3.75
8.82
3.16
10.31 2.79
10.08 2.88
9.53
3.11
9.30
3.22
8.91
3.41
8.68
3.53
8.24
3.16
10.89 2.93
10.65 3.03
10.07 3.27
9.82
3.38
9.41
3.58
9.17
3.71
8.63
3.16
11.15 3.06
10.90 3.16
10.31 3.41
10.06 3.53
9.64
3.74
9.37
3.75
8.81
3.16

SUPER MULTI NX E-Series Heat Pump

EDAU12-722

Combination
(Capacity)
2.5+3.5+7.1

2.5+5.0+5.0

2.5+5.0+6.0

2.5+6.0+6.0

3.5+3.5+3.5

3.5+3.5+5.0

3.5+3.5+6.0

3.5+3.5+7.1

3.5+5.0+5.0

Capacity Tables

Outdoor
air temp.
CDB
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0

SUPER MULTI NX E-Series Heat Pump

14C
TC
PI
kW
kW
9.12
2.79
8.87
2.89
8.28
3.15
8.03
3.27
7.60
3.48
7.35
3.61
7.10
3.16
9.53
2.79
9.26
2.89
8.64
3.15
8.38
3.27
7.94
3.48
7.67
3.61
7.36
3.16
9.64
2.86
9.37
2.96
8.74
3.22
8.48
3.34
8.03
3.56
7.76
3.69
7.46
3.16
9.66
2.87
9.39
2.97
8.76
3.23
8.49
3.35
8.05
3.57
7.78
3.70
7.47
3.16
8.63
2.60
8.39
2.69
7.83
2.93
7.59
3.04
7.19
3.23
6.95
3.35
6.70
3.16
9.04
2.79
8.79
2.89
8.21
3.14
7.95
3.26
7.54
3.47
7.28
3.60
7.03
3.16
9.12
2.79
8.87
2.89
8.28
3.14
8.03
3.26
7.60
3.47
7.35
3.60
7.09
3.16
9.10
2.79
8.85
2.89
8.26
3.15
8.01
3.27
7.59
3.48
7.33
3.61
7.08
3.16
9.64
2.86
9.37
2.96
8.74
3.22
8.48
3.34
8.03
3.56
7.76
3.69
7.46
3.16

16C
TC
PI
kW
kW
9.54
2.85
9.29
2.95
8.70
3.20
8.44
3.32
8.02
3.53
7.77
3.66
7.46
3.16
9.96
2.85
9.70
2.95
9.08
3.20
8.82
3.32
8.37
3.53
8.11
3.66
7.74
3.16
10.08 2.92
9.81
3.02
9.19
3.28
8.92
3.40
8.47
3.61
8.20
3.75
7.83
3.16
10.10 2.92
9.83
3.03
9.20
3.29
8.94
3.41
8.49
3.62
8.22
3.75
7.85
3.16
9.03
2.65
8.79
2.74
8.23
2.98
7.99
3.09
7.59
3.28
7.35
3.40
7.07
3.16
9.46
2.84
9.21
2.94
8.62
3.19
8.37
3.31
7.95
3.52
7.70
3.65
7.40
3.16
9.54
2.84
9.29
2.94
8.70
3.19
8.44
3.31
8.02
3.52
7.77
3.65
7.46
3.16
9.52
2.85
9.27
2.95
8.68
3.20
8.42
3.32
8.00
3.53
7.75
3.66
7.45
3.16
10.08 2.92
9.81
3.02
9.19
3.28
8.92
3.40
8.47
3.61
8.20
3.75
7.83
3.16

Indoor air temp.:CWB


18C
19C
TC
PI
TC
PI
kW
kW
kW
kW
9.96
2.90 10.17 2.93
9.71
3.00
9.91
3.03
9.11
3.26
9.32
3.29
8.86
3.38
9.07
3.40
8.44
3.59
8.65
3.61
8.19
3.72
8.39
3.74
7.82
3.16
8.00
3.16
10.40 2.90 10.62 2.93
10.13 3.00 10.35 3.03
9.52
3.26
9.73
3.29
9.25
3.38
9.47
3.40
8.81
3.59
9.03
3.61
8.55
3.72
8.76
3.74
8.11
3.16
8.29
3.16
10.52 2.97 10.74 3.00
10.25 3.07 10.47 3.10
9.63
3.33
9.85
3.36
9.36
3.46
9.58
3.48
8.91
3.67
9.13
3.70
8.64
3.75
8.86
3.75
8.20
3.16
8.38
3.16
10.54 2.98 10.76 3.01
10.27 3.08 10.49 3.11
9.65
3.34
9.87
3.37
9.38
3.47
9.60
3.49
8.93
3.68
9.15
3.71
8.66
3.75
8.88
3.75
8.22
3.16
8.40
3.16
9.42
2.70
9.62
2.72
9.18
2.79
9.38
2.82
8.62
3.03
8.82
3.05
8.38
3.14
8.58
3.16
7.98
3.33
8.18
3.36
7.74
3.46
7.94
3.48
7.42
3.16
7.59
3.16
9.87
2.89 10.08 2.92
9.62
2.99
9.83
3.02
9.03
3.25
9.24
3.28
8.78
3.37
8.99
3.39
8.36
3.57
8.57
3.60
8.11
3.71
8.32
3.73
7.76
3.16
7.94
3.16
9.96
2.89 10.17 2.92
9.71
2.99
9.91
3.02
9.11
3.25
9.32
3.28
8.86
3.37
9.07
3.39
8.44
3.57
8.65
3.60
8.19
3.71
8.39
3.73
7.82
3.16
7.99
3.16
9.94
2.90 10.15 2.93
9.68
3.00
9.89
3.03
9.09
3.26
9.30
3.29
8.84
3.38
9.05
3.40
8.42
3.59
8.63
3.61
8.17
3.72
8.38
3.74
7.81
3.16
7.98
3.16
10.52 2.97 10.74 3.00
10.25 3.07 10.47 3.10
9.63
3.33
9.85
3.36
9.36
3.46
9.58
3.48
8.91
3.67
9.13
3.70
8.64
3.75
8.86
3.75
8.20
3.16
8.38
3.16

22C
TC
PI
kW
kW
10.79 3.01
10.54 3.11
9.95
3.37
9.70
3.49
9.27
3.69
9.01
3.75
8.51
3.16
11.27 3.01
11.01 3.11
10.39 3.37
10.12 3.49
9.68
3.69
9.40
3.75
8.82
3.16
11.40 3.08
11.13 3.19
10.51 3.45
10.24 3.57
9.80
3.78
9.50
3.75
8.91
3.16
11.43 3.09
11.16 3.19
10.53 3.46
10.26 3.58
9.82
3.79
9.52
3.75
8.93
3.16
10.21 2.80
9.97
2.89
9.41
3.13
9.17
3.24
8.77
3.43
8.53
3.56
8.11
3.16
10.70 3.00
10.45 3.10
9.86
3.36
9.61
3.47
9.19
3.68
8.94
3.75
8.45
3.16
10.79 3.00
10.54 3.10
9.95
3.36
9.70
3.47
9.27
3.68
9.01
3.75
8.51
3.16
10.77 3.01
10.52 3.11
9.93
3.37
9.68
3.49
9.25
3.69
8.99
3.75
8.50
3.16
11.40 3.08
11.13 3.19
10.51 3.45
10.24 3.57
9.80
3.78
9.50
3.75
8.91
3.16

24C
TC
PI
kW
kW
11.21 3.07
10.96 3.17
10.37 3.42
10.11 3.54
9.69
3.75
9.42
3.75
8.85
3.16
11.71 3.07
11.44 3.17
10.83 3.42
10.56 3.54
10.12 3.75
9.82
3.75
9.17
3.16
11.84 3.14
11.58 3.24
10.95 3.50
10.68 3.62
10.24 3.84
9.91
3.75
9.26
3.16
11.87 3.15
11.60 3.25
10.97 3.51
10.71 3.63
10.26 3.85
9.93
3.75
9.28
3.16
10.61 2.85
10.37 2.94
9.81
3.18
9.57
3.29
9.17
3.48
8.93
3.61
8.44
3.16
11.11 3.06
10.86 3.16
10.28 3.41
10.03 3.53
9.61
3.74
9.34
3.75
8.79
3.16
11.21 3.06
10.96 3.16
10.37 3.41
10.11 3.53
9.69
3.74
9.42
3.75
8.85
3.16
11.19 3.07
10.94 3.17
10.35 3.42
10.09 3.54
9.67
3.75
9.40
3.75
8.84
3.16
11.84 3.14
11.58 3.24
10.95 3.50
10.68 3.62
10.24 3.84
9.91
3.75
9.26
3.16

147

Capacity Tables

Combination
(Capacity)
3.5+5.0+6.0

2.0+2.0+2.0+2.0

2.0+2.0+2.0+2.5

2.0+2.0+2.0+3.5

2.0+2.0+2.0+5.0

2.0+2.0+2.0+6.0

2.0+2.0+2.0+7.1

2.0+2.0+2.5+2.5

2.0+2.0+2.5+3.5

148

EDAU12-722

Outdoor
air temp.
CDB
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0

14C
TC
PI
kW
kW
9.66
2.87
9.39
2.97
8.76
3.23
8.49
3.35
8.05
3.57
7.78
3.70
7.47
3.16
7.95
2.02
7.73
2.09
7.21
2.28
6.99
2.36
6.62
2.52
6.40
2.61
6.18
2.71
8.21
2.13
7.98
2.20
7.45
2.40
7.22
2.49
6.84
2.65
6.61
2.75
6.38
2.85
8.67
2.39
8.43
2.48
7.87
2.70
7.63
2.80
7.23
2.98
6.98
3.09
6.74
3.16
9.20
2.56
8.95
2.66
8.35
2.89
8.10
3.00
7.67
3.19
7.41
3.31
7.11
3.16
9.45
2.74
9.18
2.84
8.57
3.09
8.31
3.21
7.87
3.42
7.61
3.55
7.29
3.16
9.61
2.81
9.34
2.91
8.72
3.17
8.45
3.29
8.01
3.50
7.74
3.63
7.42
3.16
8.45
2.28
8.21
2.37
7.67
2.58
7.43
2.67
7.04
2.84
6.81
2.95
6.57
3.06
8.87
2.67
8.63
2.77
8.05
3.01
7.80
3.12
7.39
3.32
7.15
3.45
6.89
3.16

16C
TC
PI
kW
kW
10.10 2.92
9.83
3.03
9.20
3.29
8.94
3.41
8.49
3.62
8.22
3.75
7.85
3.16
8.31
2.06
8.09
2.13
7.57
2.32
7.35
2.40
6.99
2.55
6.77
2.65
6.54
2.75
8.58
2.17
8.36
2.25
7.82
2.44
7.60
2.53
7.22
2.69
6.99
2.79
6.76
2.90
9.07
2.44
8.83
2.52
8.27
2.74
8.02
2.84
7.62
3.02
7.38
3.14
7.11
3.16
9.63
2.61
9.37
2.71
8.77
2.94
8.52
3.05
8.09
3.24
7.84
3.36
7.49
3.16
9.88
2.80
9.62
2.90
9.00
3.15
8.74
3.26
8.30
3.47
8.04
3.60
7.67
3.16
10.05 2.87
9.78
2.97
9.16
3.22
8.89
3.34
8.45
3.55
8.18
3.68
7.80
3.16
8.84
2.33
8.60
2.41
8.05
2.62
7.82
2.72
7.43
2.89
7.19
3.00
6.96
3.11
9.28
2.72
9.03
2.82
8.46
3.06
8.21
3.18
7.80
3.38
7.55
3.50
7.25
3.16

Indoor air temp.:CWB


18C
19C
TC
PI
TC
PI
kW
kW
kW
kW
10.54 2.98 10.76 3.01
10.27 3.08 10.49 3.11
9.65
3.34
9.87
3.37
9.38
3.47
9.60
3.49
8.93
3.68
9.15
3.71
8.66
3.75
8.88
3.75
8.22
3.16
8.40
3.16
8.67
2.10
8.86
2.12
8.45
2.17
8.64
2.19
7.94
2.36
8.12
2.38
7.72
2.44
7.90
2.46
7.35
2.59
7.53
2.61
7.13
2.69
7.31
2.71
6.91
2.79
7.09
2.81
8.96
2.21
9.15
2.23
8.73
2.29
8.92
2.31
8.20
2.48
8.39
2.50
7.97
2.57
8.16
2.59
7.59
2.73
7.78
2.75
7.36
2.83
7.55
2.85
7.14
2.94
7.32
2.96
9.47
2.48
9.66
2.51
9.22
2.57
9.42
2.59
8.66
2.79
8.86
2.81
8.42
2.89
8.62
2.91
8.02
3.07
8.22
3.09
7.78
3.18
7.98
3.21
7.49
3.16
7.67
3.16
10.05 2.66 10.26 2.69
9.79
2.76 10.00 2.78
9.19
2.99
9.41
3.01
8.94
3.10
9.15
3.12
8.51
3.29
8.72
3.31
8.26
3.41
8.47
3.44
7.86
3.16
8.05
3.16
10.31 2.85 10.53 2.88
10.05 2.95 10.26 2.98
9.44
3.20
9.65
3.23
9.17
3.32
9.39
3.34
8.74
3.52
8.95
3.55
8.47
3.65
8.69
3.68
8.04
3.16
8.22
3.16
10.49 2.92 10.71 2.95
10.22 3.02 10.44 3.05
9.60
3.28
9.82
3.30
9.33
3.40
9.55
3.42
8.89
3.61
9.11
3.63
8.62
3.74
8.84
3.75
8.17
3.16
8.35
3.16
9.22
2.37
9.42
2.40
8.99
2.46
9.18
2.48
8.44
2.66
8.63
2.69
8.21
2.76
8.40
2.78
7.82
2.93
8.01
2.95
7.58
3.04
7.77
3.06
7.35
3.15
7.53
3.16
9.68
2.77
9.89
2.80
9.44
2.87
9.64
2.90
8.86
3.11
9.07
3.14
8.62
3.23
8.82
3.25
8.21
3.43
8.41
3.45
7.96
3.55
8.16
3.58
7.61
3.16
7.79
3.16

22C
TC
PI
kW
kW
11.43 3.09
11.16 3.19
10.53 3.46
10.26 3.58
9.82
3.79
9.52
3.75
8.93
3.16
9.40
2.18
9.18
2.25
8.67
2.44
8.45
2.52
8.08
2.67
7.86
2.77
7.64
2.87
9.71
2.29
9.48
2.37
8.95
2.56
8.72
2.65
8.34
2.81
8.12
2.91
7.89
3.02
10.26 2.58
10.02 2.66
9.46
2.88
9.22
2.98
8.81
3.16
8.57
3.27
8.20
3.16
10.89 2.76
10.63 2.86
10.04 3.09
9.78
3.20
9.36
3.39
9.10
3.51
8.59
3.16
11.18 2.96
10.91 3.06
10.30 3.31
10.04 3.42
9.60
3.63
9.34
3.75
8.76
3.16
11.37 3.03
11.10 3.13
10.48 3.39
10.21 3.51
9.77
3.72
9.48
3.75
8.89
3.16
10.00 2.46
9.76
2.54
9.22
2.75
8.98
2.85
8.59
3.02
8.35
3.13
8.07
3.16
10.50 2.88
10.25 2.97
9.68
3.22
9.43
3.33
9.02
3.53
8.77
3.66
8.30
3.16

24C
TC
PI
kW
kW
11.87 3.15
11.60 3.25
10.97 3.51
10.71 3.63
10.26 3.85
9.93
3.75
9.28
3.16
9.77
2.22
9.55
2.29
9.03
2.48
8.81
2.56
8.44
2.71
8.22
2.81
8.00
2.91
10.09 2.34
9.86
2.41
9.33
2.61
9.10
2.70
8.72
2.86
8.49
2.96
8.26
3.06
10.66 2.62
10.42 2.71
9.85
2.93
9.61
3.03
9.21
3.21
8.97
3.32
8.55
3.16
11.31 2.81
11.06 2.91
10.46 3.14
10.20 3.25
9.78
3.44
9.52
3.56
8.94
3.16
11.61 3.01
11.35 3.11
10.73 3.36
10.47 3.48
10.03 3.68
9.75
3.75
9.11
3.16
11.81 3.08
11.54 3.19
10.92 3.44
10.65 3.56
10.21 3.77
9.89
3.75
9.23
3.16
10.38 2.51
10.15 2.59
9.60
2.80
9.37
2.89
8.98
3.06
8.74
3.17
8.42
3.16
10.90 2.93
10.66 3.03
10.08 3.27
9.84
3.38
9.43
3.58
9.18
3.71
8.64
3.16

SUPER MULTI NX E-Series Heat Pump

EDAU12-722

Combination
(Capacity)
2.0+2.0+2.5+5.0

2.0+2.0+2.5+6.0

2.0+2.0+2.5+7.1

2.0+2.0+3.5+3.5

2.0+2.0+3.5+5.0

2.0+2.0+3.5+6.0

2.0+2.0+5.0+5.0

2.0+2.5+2.5+2.5

2.0+2.5+2.5+3.5

Capacity Tables

Outdoor
air temp.
CDB
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0

SUPER MULTI NX E-Series Heat Pump

14C
TC
PI
kW
kW
9.33
2.68
9.08
2.78
8.47
3.02
8.21
3.13
7.78
3.33
7.52
3.46
7.21
3.16
9.53
2.74
9.26
2.84
8.64
3.09
8.38
3.21
7.94
3.42
7.67
3.55
7.35
3.16
9.65
2.88
9.38
2.98
8.75
3.24
8.49
3.36
8.04
3.58
7.77
3.71
7.47
3.16
8.91
2.67
8.66
2.77
8.09
3.01
7.84
3.12
7.43
3.32
7.18
3.45
6.92
3.16
9.53
2.80
9.26
2.90
8.64
3.16
8.38
3.28
7.94
3.49
7.67
3.62
7.36
3.16
9.64
2.87
9.37
2.97
8.74
3.23
8.48
3.35
8.03
3.57
7.76
3.70
7.46
3.16
9.66
2.56
9.39
2.65
8.76
2.88
8.49
2.99
8.05
3.18
7.78
3.30
7.43
3.16
8.67
2.39
8.43
2.48
7.87
2.70
7.63
2.80
7.23
2.98
6.98
3.09
6.74
3.16
8.91
2.67
8.66
2.77
8.09
3.01
7.84
3.12
7.43
3.32
7.18
3.45
6.92
3.16

16C
TC
PI
kW
kW
9.76
2.73
9.50
2.83
8.90
3.07
8.64
3.19
8.21
3.39
7.95
3.51
7.59
3.16
9.96
2.80
9.70
2.90
9.08
3.15
8.82
3.26
8.37
3.47
8.11
3.60
7.73
3.16
10.09 2.93
9.82
3.04
9.20
3.30
8.93
3.42
8.48
3.63
8.21
3.75
7.84
3.16
9.32
2.72
9.07
2.82
8.50
3.06
8.25
3.18
7.84
3.38
7.59
3.50
7.28
3.16
9.96
2.86
9.70
2.96
9.08
3.21
8.82
3.33
8.37
3.54
8.11
3.67
7.74
3.16
10.08 2.92
9.81
3.03
9.19
3.29
8.92
3.41
8.47
3.62
8.20
3.75
7.83
3.16
10.10 2.61
9.83
2.70
9.20
2.93
8.94
3.04
8.49
3.23
8.22
3.35
7.83
3.16
9.07
2.44
8.83
2.52
8.27
2.74
8.02
2.84
7.62
3.02
7.38
3.14
7.11
3.16
9.32
2.72
9.07
2.82
8.50
3.06
8.25
3.18
7.84
3.38
7.59
3.50
7.28
3.16

Indoor air temp.:CWB


18C
19C
TC
PI
TC
PI
kW
kW
kW
kW
10.19 2.78 10.40 2.81
9.93
2.88 10.14 2.91
9.33
3.12
9.54
3.15
9.07
3.24
9.28
3.26
8.63
3.44
8.85
3.46
8.37
3.56
8.59
3.59
7.96
3.16
8.14
3.16
10.40 2.85 10.62 2.88
10.13 2.95 10.35 2.98
9.52
3.20
9.73
3.23
9.25
3.32
9.47
3.34
8.81
3.52
9.03
3.55
8.55
3.65
8.76
3.68
8.10
3.16
8.28
3.16
10.53 2.99 10.75 3.02
10.26 3.09 10.48 3.12
9.64
3.35
9.86
3.38
9.37
3.48
9.59
3.50
8.92
3.69
9.14
3.72
8.65
3.75
8.87
3.75
8.21
3.16
8.39
3.16
9.73
2.77
9.93
2.80
9.48
2.87
9.69
2.90
8.90
3.11
9.11
3.14
8.66
3.23
8.86
3.25
8.24
3.43
8.45
3.45
8.00
3.55
8.20
3.58
7.64
3.16
7.82
3.16
10.40 2.91 10.62 2.94
10.13 3.01 10.35 3.04
9.52
3.27
9.73
3.30
9.25
3.39
9.47
3.41
8.81
3.60
9.03
3.62
8.55
3.73
8.76
3.75
8.11
3.16
8.29
3.16
10.52 2.98 10.74 3.01
10.25 3.08 10.47 3.11
9.63
3.34
9.85
3.37
9.36
3.47
9.58
3.49
8.91
3.68
9.13
3.71
8.64
3.75
8.86
3.75
8.20
3.16
8.38
3.16
10.54 2.66 10.76 2.68
10.27 2.75 10.49 2.77
9.65
2.98
9.87
3.01
9.38
3.09
9.60
3.11
8.93
3.28
9.15
3.30
8.66
3.40
8.88
3.43
8.22
3.16
8.41
3.16
9.47
2.48
9.66
2.51
9.22
2.57
9.42
2.59
8.66
2.79
8.86
2.81
8.42
2.89
8.62
2.91
8.02
3.07
8.22
3.09
7.78
3.18
7.98
3.21
7.49
3.16
7.67
3.16
9.73
2.77
9.93
2.80
9.48
2.87
9.69
2.90
8.90
3.11
9.11
3.14
8.66
3.23
8.86
3.25
8.24
3.43
8.45
3.45
8.00
3.55
8.20
3.58
7.64
3.16
7.82
3.16

22C
TC
PI
kW
kW
11.04 2.89
10.79 2.98
10.18 3.23
9.92
3.34
9.49
3.54
9.23
3.67
8.67
3.16
11.27 2.96
11.01 3.06
10.39 3.31
10.12 3.42
9.68
3.63
9.42
3.75
8.82
3.16
11.41 3.10
11.15 3.20
10.52 3.47
10.25 3.59
9.81
3.80
9.51
3.75
8.93
3.16
10.54 2.88
10.30 2.97
9.72
3.22
9.47
3.33
9.06
3.53
8.81
3.66
8.34
3.16
11.27 3.02
11.01 3.12
10.39 3.38
10.12 3.50
9.68
3.70
9.40
3.75
8.82
3.16
11.40 3.09
11.13 3.19
10.51 3.46
10.24 3.58
9.80
3.79
9.50
3.75
8.92
3.16
11.43 2.75
11.16 2.85
10.53 3.08
10.26 3.19
9.82
3.38
9.55
3.50
8.97
3.16
10.26 2.58
10.02 2.66
9.46
2.88
9.22
2.98
8.81
3.16
8.57
3.27
8.20
3.16
10.54 2.88
10.30 2.97
9.72
3.22
9.47
3.33
9.06
3.53
8.81
3.66
8.34
3.16

24C
TC
PI
kW
kW
11.47 2.94
11.21 3.04
10.61 3.28
10.35 3.39
9.92
3.59
9.66
3.72
9.02
3.16
11.71 3.01
11.44 3.11
10.83 3.36
10.56 3.48
10.12 3.68
9.83
3.75
9.17
3.16
11.86 3.16
11.59 3.26
10.96 3.52
10.69 3.64
10.25 3.86
9.92
3.75
9.27
3.16
10.95 2.93
10.71 3.03
10.13 3.27
9.88
3.38
9.47
3.58
9.22
3.71
8.67
3.16
11.71 3.08
11.44 3.18
10.83 3.43
10.56 3.55
10.12 3.76
9.82
3.75
9.17
3.16
11.84 3.15
11.58 3.25
10.95 3.51
10.68 3.63
10.24 3.85
9.91
3.75
9.26
3.16
11.87 2.80
11.60 2.90
10.97 3.13
10.71 3.24
10.26 3.43
9.99
3.55
9.34
3.16
10.66 2.62
10.42 2.71
9.85
2.93
9.61
3.03
9.21
3.21
8.97
3.32
8.55
3.16
10.95 2.93
10.71 3.03
10.13 3.27
9.88
3.38
9.47
3.58
9.22
3.71
8.67
3.16

149

Capacity Tables

Combination
(Capacity)
2.0+2.5+2.5+5.0

2.0+2.5+2.5+6.0

2.0+2.5+2.5+7.1

2.0+2.5+3.5+3.5

2.0+2.5+3.5+5.0

2.0+2.5+3.5+6.0

2.0+2.5+5.0+5.0

2.0+3.5+3.5+3.5

2.0+3.5+3.5+5.0

150

EDAU12-722

Outdoor
air temp.
CDB
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0

14C
TC
PI
kW
kW
9.45
2.74
9.18
2.84
8.57
3.09
8.31
3.21
7.87
3.42
7.61
3.55
7.29
3.16
9.60
2.81
9.33
2.91
8.71
3.17
8.44
3.29
8.00
3.50
7.73
3.63
7.41
3.16
9.66
2.88
9.39
2.98
8.76
3.24
8.49
3.36
8.05
3.58
7.78
3.71
7.47
3.16
9.14
2.79
8.89
2.89
8.30
3.15
8.04
3.27
7.62
3.48
7.37
3.61
7.11
3.16
9.60
2.87
9.33
2.97
8.71
3.23
8.44
3.35
8.00
3.57
7.73
3.70
7.43
3.16
9.66
2.87
9.39
2.97
8.76
3.23
8.49
3.35
8.05
3.57
7.78
3.70
7.47
3.16
9.66
2.56
9.39
2.65
8.76
2.88
8.49
2.99
8.05
3.18
7.78
3.30
7.43
3.16
9.28
2.79
9.03
2.89
8.42
3.15
8.17
3.27
7.74
3.48
7.48
3.61
7.20
3.16
9.66
2.87
9.39
2.97
8.76
3.23
8.49
3.35
8.05
3.57
7.78
3.70
7.47
3.16

16C
TC
PI
kW
kW
9.88
2.80
9.62
2.90
9.00
3.15
8.74
3.26
8.30
3.47
8.04
3.60
7.67
3.16
10.04 2.87
9.77
2.97
9.15
3.22
8.88
3.34
8.44
3.55
8.17
3.68
7.79
3.16
10.10 2.93
9.83
3.04
9.20
3.30
8.94
3.42
8.49
3.63
8.22
3.75
7.85
3.16
9.56
2.85
9.31
2.95
8.72
3.20
8.46
3.32
8.04
3.53
7.78
3.66
7.48
3.16
10.04 2.92
9.77
3.03
9.15
3.29
8.88
3.41
8.44
3.62
8.17
3.75
7.81
3.16
10.10 2.92
9.83
3.03
9.20
3.29
8.94
3.41
8.49
3.62
8.22
3.75
7.85
3.16
10.10 2.61
9.83
2.70
9.20
2.93
8.94
3.04
8.49
3.23
8.22
3.35
7.83
3.16
9.71
2.85
9.45
2.95
8.85
3.20
8.59
3.32
8.16
3.53
7.90
3.66
7.57
3.16
10.10 2.92
9.83
3.03
9.20
3.29
8.94
3.41
8.49
3.62
8.22
3.75
7.85
3.16

Indoor air temp.:CWB


18C
19C
TC
PI
TC
PI
kW
kW
kW
kW
10.31 2.85 10.53 2.88
10.05 2.95 10.26 2.98
9.44
3.20
9.65
3.23
9.17
3.32
9.39
3.34
8.74
3.52
8.95
3.55
8.47
3.65
8.69
3.68
8.04
3.16
8.22
3.16
10.48 2.92 10.69 2.95
10.21 3.02 10.43 3.05
9.59
3.28
9.81
3.30
9.32
3.40
9.54
3.42
8.88
3.61
9.10
3.63
8.61
3.74
8.83
3.75
8.16
3.16
8.34
3.16
10.54 2.99 10.76 3.02
10.27 3.09 10.49 3.12
9.65
3.35
9.87
3.38
9.38
3.48
9.60
3.50
8.93
3.69
9.15
3.72
8.66
3.75
8.88
3.75
8.22
3.16
8.40
3.16
9.98
2.90 10.19 2.93
9.73
3.00
9.94
3.03
9.13
3.26
9.34
3.29
8.88
3.38
9.09
3.40
8.46
3.59
8.67
3.61
8.20
3.72
8.41
3.74
7.83
3.16
8.01
3.16
10.48 2.98 10.69 3.01
10.21 3.08 10.43 3.11
9.59
3.34
9.81
3.37
9.32
3.47
9.54
3.49
8.88
3.68
9.10
3.71
8.61
3.75
8.82
3.75
8.17
3.16
8.35
3.16
10.54 2.98 10.76 3.01
10.27 3.08 10.49 3.11
9.65
3.34
9.87
3.37
9.38
3.47
9.60
3.49
8.93
3.68
9.15
3.71
8.66
3.75
8.88
3.75
8.22
3.16
8.40
3.16
10.54 2.66 10.76 2.68
10.27 2.75 10.49 2.77
9.65
2.98
9.87
3.01
9.38
3.09
9.60
3.11
8.93
3.28
9.15
3.30
8.66
3.40
8.88
3.43
8.22
3.16
8.41
3.16
10.13 2.90 10.35 2.93
9.88
3.00 10.09 3.03
9.28
3.26
9.49
3.29
9.02
3.38
9.23
3.40
8.59
3.59
8.80
3.61
8.33
3.72
8.54
3.74
7.93
3.16
8.11
3.16
10.54 2.98 10.76 3.01
10.27 3.08 10.49 3.11
9.65
3.34
9.87
3.37
9.38
3.47
9.60
3.49
8.93
3.68
9.15
3.71
8.66
3.75
8.88
3.75
8.22
3.16
8.40
3.16

22C
TC
PI
kW
kW
11.18 2.96
10.91 3.06
10.30 3.31
10.04 3.42
9.60
3.63
9.34
3.75
8.76
3.16
11.35 3.03
11.09 3.13
10.47 3.39
10.20 3.51
9.76
3.72
9.47
3.75
8.88
3.16
11.43 3.10
11.16 3.20
10.53 3.47
10.26 3.59
9.82
3.80
9.52
3.75
8.93
3.16
10.82 3.01
10.56 3.11
9.97
3.37
9.72
3.49
9.29
3.69
9.03
3.75
8.53
3.16
11.35 3.09
11.09 3.19
10.47 3.46
10.20 3.58
9.76
3.79
9.46
3.75
8.89
3.16
11.43 3.09
11.16 3.19
10.53 3.46
10.26 3.58
9.82
3.79
9.52
3.75
8.93
3.16
11.43 2.75
11.16 2.85
10.53 3.08
10.26 3.19
9.82
3.38
9.55
3.50
8.97
3.16
10.99 3.01
10.73 3.11
10.13 3.37
9.87
3.49
9.44
3.69
9.17
3.75
8.64
3.16
11.43 3.09
11.16 3.19
10.53 3.46
10.26 3.58
9.82
3.79
9.52
3.75
8.93
3.16

24C
TC
PI
kW
kW
11.61 3.01
11.35 3.11
10.73 3.36
10.47 3.48
10.03 3.68
9.75
3.75
9.11
3.16
11.79 3.08
11.53 3.19
10.91 3.44
10.64 3.56
10.19 3.77
9.88
3.75
9.23
3.16
11.87 3.16
11.60 3.26
10.97 3.52
10.71 3.64
10.26 3.86
9.93
3.75
9.28
3.16
11.24 3.07
10.98 3.17
10.39 3.42
10.14 3.54
9.71
3.75
9.44
3.75
8.87
3.16
11.79 3.15
11.53 3.25
10.91 3.51
10.64 3.63
10.19 3.85
9.87
3.75
9.23
3.16
11.87 3.15
11.60 3.25
10.97 3.51
10.71 3.63
10.26 3.85
9.93
3.75
9.28
3.16
11.87 2.80
11.60 2.90
10.97 3.13
10.71 3.24
10.26 3.43
9.99
3.55
9.34
3.16
11.41 3.07
11.15 3.17
10.55 3.42
10.29 3.54
9.86
3.75
9.58
3.75
8.98
3.16
11.87 3.15
11.60 3.25
10.97 3.51
10.71 3.63
10.26 3.85
9.93
3.75
9.28
3.16

SUPER MULTI NX E-Series Heat Pump

EDAU12-722

Combination
(Capacity)
2.5+2.5+2.5+2.5

2.5+2.5+2.5+3.5

2.5+2.5+2.5+5.0

2.5+2.5+2.5+6.0

2.5+2.5+3.5+3.5

2.5+2.5+3.5+5.0

2.5+2.5+3.5+6.0

2.5+3.5+3.5+3.5

2.5+3.5+3.5+5.0

Capacity Tables

Outdoor
air temp.
CDB
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0
22.0
25.0
32.0
35.0
40.0
43.0
46.0

SUPER MULTI NX E-Series Heat Pump

14C
TC
PI
kW
kW
8.87
2.67
8.63
2.77
8.05
3.01
7.80
3.12
7.39
3.32
7.15
3.45
6.89
3.16
8.97
2.67
8.72
2.77
8.14
3.01
7.89
3.12
7.48
3.32
7.23
3.45
6.96
3.16
9.53
2.80
9.26
2.90
8.64
3.16
8.38
3.28
7.94
3.49
7.67
3.62
7.36
3.16
9.64
2.87
9.37
2.97
8.74
3.23
8.48
3.35
8.03
3.57
7.76
3.70
7.46
3.16
9.09
2.79
8.84
2.89
8.25
3.15
8.00
3.27
7.58
3.48
7.33
3.61
7.07
3.16
9.64
2.87
9.37
2.97
8.74
3.23
8.48
3.35
8.03
3.57
7.76
3.70
7.46
3.16
9.66
2.87
9.39
2.97
8.76
3.23
8.49
3.35
8.05
3.57
7.78
3.70
7.47
3.16
9.39
2.79
9.13
2.89
8.53
3.15
8.26
3.27
7.83
3.48
7.57
3.61
7.28
3.16
9.66
2.87
9.39
2.97
8.76
3.23
8.49
3.35
8.05
3.57
7.78
3.70
7.47
3.16

16C
TC
PI
kW
kW
9.28
2.72
9.03
2.82
8.46
3.06
8.21
3.18
7.80
3.38
7.55
3.50
7.25
3.16
9.38
2.72
9.13
2.82
8.55
3.06
8.30
3.18
7.89
3.38
7.64
3.50
7.32
3.16
9.96
2.86
9.70
2.96
9.08
3.21
8.82
3.33
8.37
3.54
8.11
3.67
7.74
3.16
10.08 2.92
9.81
3.03
9.19
3.29
8.92
3.41
8.47
3.62
8.20
3.75
7.83
3.16
9.51
2.85
9.26
2.95
8.67
3.20
8.42
3.32
7.99
3.53
7.74
3.66
7.44
3.16
10.08 2.92
9.81
3.03
9.19
3.29
8.92
3.41
8.47
3.62
8.20
3.75
7.83
3.16
10.10 2.92
9.83
3.03
9.20
3.29
8.94
3.41
8.49
3.62
8.22
3.75
7.85
3.16
9.83
2.85
9.56
2.95
8.96
3.20
8.69
3.32
8.26
3.53
8.00
3.66
7.65
3.16
10.10 2.92
9.83
3.03
9.20
3.29
8.94
3.41
8.49
3.62
8.22
3.75
7.85
3.16

Indoor air temp.:CWB


18C
19C
TC
PI
TC
PI
kW
kW
kW
kW
9.68
2.77
9.89
2.80
9.44
2.87
9.64
2.90
8.86
3.11
9.07
3.14
8.62
3.23
8.82
3.25
8.21
3.43
8.41
3.45
7.96
3.55
8.16
3.58
7.61
3.16
7.79
3.16
9.79
2.77 10.00 2.80
9.55
2.87
9.75
2.90
8.96
3.11
9.17
3.14
8.71
3.23
8.92
3.25
8.30
3.43
8.50
3.45
8.05
3.55
8.26
3.58
7.69
3.16
7.86
3.16
10.40 2.91 10.62 2.94
10.13 3.01 10.35 3.04
9.52
3.27
9.73
3.30
9.25
3.39
9.47
3.41
8.81
3.60
9.03
3.62
8.55
3.73
8.76
3.75
8.11
3.16
8.29
3.16
10.52 2.98 10.74 3.01
10.25 3.08 10.47 3.11
9.63
3.34
9.85
3.37
9.36
3.47
9.58
3.49
8.91
3.68
9.13
3.71
8.64
3.75
8.86
3.75
8.20
3.16
8.38
3.16
9.93
2.90 10.13 2.93
9.67
3.00
9.88
3.03
9.08
3.26
9.29
3.29
8.83
3.38
9.04
3.40
8.41
3.59
8.62
3.61
8.16
3.72
8.37
3.74
7.80
3.16
7.97
3.16
10.52 2.98 10.74 3.01
10.25 3.08 10.47 3.11
9.63
3.34
9.85
3.37
9.36
3.47
9.58
3.49
8.91
3.68
9.13
3.71
8.64
3.75
8.86
3.75
8.20
3.16
8.38
3.16
10.54 2.98 10.76 3.01
10.27 3.08 10.49 3.11
9.65
3.34
9.87
3.37
9.38
3.47
9.60
3.49
8.93
3.68
9.15
3.71
8.66
3.75
8.88
3.75
8.22
3.16
8.40
3.16
10.26 2.90 10.47 2.93
9.99
3.00 10.21 3.03
9.39
3.26
9.60
3.29
9.12
3.38
9.34
3.40
8.69
3.59
8.91
3.61
8.43
3.72
8.64
3.74
8.01
3.16
8.19
3.16
10.54 2.98 10.76 3.01
10.27 3.08 10.49 3.11
9.65
3.34
9.87
3.37
9.38
3.47
9.60
3.49
8.93
3.68
9.15
3.71
8.66
3.75
8.88
3.75
8.22
3.16
8.40
3.16

22C
TC
PI
kW
kW
10.50 2.88
10.25 2.97
9.68
3.22
9.43
3.33
9.02
3.53
8.77
3.66
8.30
3.16
10.62 2.88
10.37 2.97
9.79
3.22
9.54
3.33
9.12
3.53
8.87
3.66
8.39
3.16
11.27 3.02
11.01 3.12
10.39 3.38
10.12 3.50
9.68
3.70
9.40
3.75
8.82
3.16
11.40 3.09
11.13 3.19
10.51 3.46
10.24 3.58
9.80
3.79
9.50
3.75
8.92
3.16
10.76 3.01
10.51 3.11
9.92
3.37
9.66
3.49
9.24
3.69
8.98
3.75
8.49
3.16
11.40 3.09
11.13 3.19
10.51 3.46
10.24 3.58
9.80
3.79
9.50
3.75
8.92
3.16
11.43 3.09
11.16 3.19
10.53 3.46
10.26 3.58
9.82
3.79
9.52
3.75
8.93
3.16
11.12 3.01
10.86 3.11
10.25 3.37
9.99
3.49
9.55
3.69
9.28
3.75
8.72
3.16
11.43 3.09
11.16 3.19
10.53 3.46
10.26 3.58
9.82
3.79
9.52
3.75
8.93
3.16

24C
TC
PI
kW
kW
10.90 2.93
10.66 3.03
10.08 3.27
9.84
3.38
9.43
3.58
9.18
3.71
8.64
3.16
11.03 2.93
10.78 3.03
10.20 3.27
9.95
3.38
9.53
3.58
9.28
3.71
8.72
3.16
11.71 3.08
11.44 3.18
10.83 3.43
10.56 3.55
10.12 3.76
9.82
3.75
9.17
3.16
11.84 3.15
11.58 3.25
10.95 3.51
10.68 3.63
10.24 3.85
9.91
3.75
9.26
3.16
11.18 3.07
10.92 3.17
10.33 3.42
10.08 3.54
9.66
3.75
9.39
3.75
8.83
3.16
11.84 3.15
11.58 3.25
10.95 3.51
10.68 3.63
10.24 3.85
9.91
3.75
9.26
3.16
11.87 3.15
11.60 3.25
10.97 3.51
10.71 3.63
10.26 3.85
9.93
3.75
9.28
3.16
11.55 3.07
11.29 3.17
10.68 3.42
10.42 3.54
9.98
3.75
9.69
3.75
9.07
3.16
11.87 3.15
11.60 3.25
10.97 3.51
10.71 3.63
10.26 3.85
9.93
3.75
9.28
3.16

151

Capacity Tables

Combination
(Capacity)
3.5+3.5+3.5+3.5

EDAU12-722

Outdoor
air temp.
CDB
22.0
25.0
32.0
35.0
40.0
43.0
46.0

Symbols

14C
TC
PI
kW
kW
9.10
2.79
8.85
2.89
8.26
3.15
8.01
3.27
7.59
3.48
7.33
3.61
7.08
3.16

16C
TC
PI
kW
kW
9.52
2.85
9.27
2.95
8.68
3.20
8.42
3.32
8.00
3.53
7.75
3.66
7.45
3.16

Indoor air temp.:CWB


18C
19C
TC
PI
TC
PI
kW
kW
kW
kW
9.94
2.90 10.15 2.93
9.68
3.00
9.89
3.03
9.09
3.26
9.30
3.29
8.84
3.38
9.05
3.40
8.42
3.59
8.63
3.61
8.17
3.72
8.38
3.74
7.81
3.16
7.98
3.16

22C
TC
PI
kW
kW
10.77 3.01
10.52 3.11
9.93
3.37
9.68
3.49
9.25
3.69
8.99
3.75
8.50
3.16

24C
TC
PI
kW
kW
11.19 3.07
10.94 3.17
10.35 3.42
10.09 3.54
9.67
3.75
9.40
3.75
8.84
3.16

NOTE:

TC

: Total capacity

(kW)

PI

: Power input

(kW)

Capacities are based on the following conditions.


Corresponding refrigerant piping length : 7.5m
Level difference : 0m
3D052672#1
3D052672#2
3D052672#3
3D052672#4
3D052672#5
3D052672#6
3D052672#7
3D052672#8
3D052672#9

152

SUPER MULTI NX E-Series Heat Pump

EDAU12-722

Capacity Tables

[Heating Capacity 50Hz 240V]


Combination
(Capacity)
2.0

2.5

3.5

5.0

6.0

7.1

2.0+2.0

2.0+2.5

2.0+3.5

Outdoor
air temp.
CWB
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0

SUPER MULTI NX E-Series Heat Pump

16C
TC
PI
kW
kW
2.27
1.04
2.73
1.10
3.19
1.15
3.66
1.20
4.21
1.27
4.58
1.31
5.05
1.36
2.52
1.12
3.03
1.18
3.55
1.24
4.06
1.30
4.68
1.36
5.09
1.41
5.60
1.47
2.73
1.45
3.29
1.52
3.85
1.60
4.41
1.67
5.08
1.76
5.52
1.82
5.78
1.73
3.83
1.80
4.61
1.90
5.39
1.99
6.17
2.08
7.11
2.19
7.74
2.26
8.52
2.36
4.38
2.13
5.28
2.24
6.17
2.34
7.07
2.45
8.14
2.58
8.85
2.67
9.68
2.74
4.81
2.40
5.80
2.53
6.78
2.65
7.76
2.77
8.94
2.92
9.73
3.01
10.58 3.06
3.62
1.50
4.36
1.57
5.10
1.65
5.84
1.73
6.73
1.82
7.32
1.88
8.06
1.95
3.79
1.56
4.56
1.64
5.34
1.72
6.11
1.80
7.04
1.90
7.66
1.96
8.43
2.04
4.07
1.83
4.90
1.92
5.73
2.01
6.56
2.11
7.55
2.22
8.22
2.29
9.05
2.39

18C
TC
PI
kW
kW
2.21
1.06
2.68
1.11
3.14
1.16
3.60
1.21
4.16
1.28
4.53
1.32
4.99
1.37
2.45
1.14
2.97
1.19
3.48
1.25
4.00
1.31
4.61
1.38
5.02
1.42
5.31
1.39
2.67
1.46
3.22
1.54
3.78
1.61
4.34
1.69
5.01
1.77
5.45
1.83
5.48
1.63
3.73
1.82
4.52
1.92
5.30
2.01
6.08
2.10
7.02
2.21
7.64
2.28
8.42
2.38
4.27
2.15
5.17
2.26
6.06
2.37
6.96
2.48
8.03
2.61
8.74
2.69
9.18
2.54
4.69
2.43
5.68
2.55
6.66
2.67
7.64
2.80
8.82
2.94
9.61
3.04
10.04 2.82
3.53
1.51
4.27
1.59
5.01
1.67
5.75
1.74
6.64
1.83
7.23
1.89
7.97
1.97
3.70
1.58
4.47
1.66
5.24
1.74
6.02
1.82
6.94
1.91
7.56
1.98
8.34
2.06
3.97
1.85
4.80
1.94
5.63
2.03
6.46
2.13
7.45
2.24
8.12
2.31
8.95
2.41

Indoor air temp.:CDB


20C
21C
TC
PI
TC
PI
kW
kW
kW
kW
2.16
1.07
2.13
1.07
2.62
1.12
2.59
1.13
3.08
1.17
3.05
1.18
3.54
1.23
3.52
1.23
4.10
1.29
4.07
1.30
4.47
1.33
4.44
1.34
4.93
1.39
4.91
1.39
2.39
1.15
2.36
1.16
2.91
1.21
2.87
1.21
3.42
1.26
3.39
1.27
3.93
1.32
3.90
1.33
4.55
1.39
4.52
1.40
4.96
1.44
4.88
1.42
5.02
1.31
4.88
1.27
2.60
1.48
2.56
1.49
3.15
1.55
3.12
1.56
3.71
1.63
3.68
1.64
4.27
1.70
4.24
1.71
4.94
1.79
4.91
1.80
5.18
1.73
5.04
1.68
5.18
1.53
5.04
1.48
3.64
1.84
3.59
1.85
4.42
1.94
4.37
1.95
5.20
2.03
5.15
2.04
5.98
2.12
5.93
2.13
6.92
2.23
6.87
2.24
7.55
2.30
7.50
2.31
8.15
2.30
7.92
2.21
4.16
2.18
4.11
2.19
5.06
2.28
5.00
2.30
5.95
2.39
5.90
2.40
6.85
2.50
6.79
2.51
7.92
2.63
7.87
2.64
8.64
2.72
8.44
2.64
8.69
2.35
8.44
2.26
4.57
2.46
4.51
2.47
5.56
2.58
5.50
2.59
6.54
2.70
6.48
2.71
7.52
2.82
7.46
2.84
8.70
2.97
8.64
2.98
9.49
3.07
9.23
2.94
9.50
2.60
9.23
2.49
3.44
1.53
3.40
1.54
4.18
1.61
4.14
1.61
4.92
1.68
4.88
1.69
5.66
1.76
5.62
1.77
6.55
1.85
6.50
1.86
7.14
1.91
7.10
1.92
7.88
1.99
7.84
2.00
3.60
1.60
3.55
1.60
4.37
1.68
4.33
1.68
5.15
1.76
5.10
1.76
5.92
1.83
5.87
1.84
6.85
1.93
6.80
1.94
7.47
1.99
7.42
2.00
8.24
2.07
8.19
2.08
3.86
1.87
3.81
1.88
4.69
1.96
4.64
1.97
5.52
2.06
5.47
2.07
6.35
2.15
6.30
2.16
7.35
2.26
7.30
2.27
8.01
2.33
7.96
2.34
8.84
2.43
8.79
2.44

22C
TC
PI
kW
kW
2.10
1.08
2.56
1.13
3.02
1.18
3.49
1.24
4.04
1.30
4.41
1.34
4.88
1.40
2.33
1.16
2.84
1.22
3.36
1.28
3.87
1.33
4.49
1.40
4.74
1.38
4.74
1.23
2.53
1.50
3.09
1.57
3.64
1.64
4.20
1.72
4.87
1.81
4.89
1.62
4.89
1.43
3.54
1.86
4.32
1.96
5.11
2.05
5.89
2.14
6.82
2.25
7.45
2.32
7.69
2.12
4.05
2.20
4.95
2.31
5.84
2.42
6.74
2.52
7.81
2.65
8.19
2.53
8.19
2.17
4.45
2.48
5.44
2.61
6.42
2.73
7.40
2.85
8.58
3.00
8.95
2.81
8.95
2.39
3.35
1.55
4.09
1.62
4.83
1.70
5.57
1.78
6.46
1.87
7.05
1.93
7.79
2.00
3.51
1.61
4.28
1.69
5.05
1.77
5.83
1.85
6.76
1.95
7.37
2.01
8.15
2.09
3.76
1.89
4.59
1.98
5.42
2.08
6.25
2.17
7.25
2.28
7.91
2.35
8.74
2.45

24C
TC
PI
kW
kW
2.04
1.09
2.51
1.14
2.97
1.20
3.43
1.25
3.99
1.31
4.36
1.36
4.63
1.32
2.27
1.17
2.78
1.23
3.29
1.29
3.81
1.35
4.42
1.42
4.45
1.29
4.45
1.15
2.46
1.51
3.02
1.59
3.58
1.66
4.13
1.73
4.59
1.69
4.59
1.51
4.59
1.34
3.45
1.88
4.23
1.98
5.01
2.07
5.79
2.16
6.73
2.27
7.22
2.26
7.22
1.96
3.95
2.22
4.84
2.33
5.73
2.44
6.63
2.55
7.70
2.67
7.70
2.32
7.70
1.99
4.33
2.51
5.32
2.63
6.30
2.75
7.28
2.88
8.41
2.99
8.41
2.56
8.41
2.18
3.26
1.56
4.00
1.64
4.74
1.72
5.48
1.79
6.37
1.88
6.96
1.94
7.70
2.02
3.41
1.63
4.19
1.71
4.96
1.79
5.73
1.87
6.66
1.96
7.28
2.03
8.05
2.11
3.66
1.91
4.49
2.00
5.32
2.10
6.15
2.19
7.15
2.30
7.81
2.38
8.64
2.47

153

Capacity Tables

Combination
(Capacity)
2.0+5.0

2.0+6.0

2.0+7.1

2.5+2.5

2.5+3.5

2.5+5.0

2.5+6.0

2.5+7.1

3.5+3.5

154

EDAU12-722

Outdoor
air temp.
CWB
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0

16C
TC
PI
kW
kW
4.72
1.94
5.68
2.04
6.65
2.14
7.61
2.24
8.77
2.36
9.54
2.44
10.50 2.53
5.17
2.14
6.23
2.24
7.29
2.35
8.34
2.46
9.61
2.59
10.45 2.68
11.51 2.79
5.54
2.30
6.68
2.41
7.81
2.53
8.94
2.65
10.30 2.79
11.20 2.88
12.33 3.00
3.83
1.76
4.61
1.84
5.39
1.93
6.17
2.02
7.11
2.13
7.74
2.20
8.52
2.29
4.56
2.16
5.49
2.27
6.42
2.38
7.35
2.49
8.47
2.62
9.21
2.71
10.14 2.82
5.06
2.15
6.09
2.26
7.12
2.37
8.15
2.48
9.39
2.61
10.22 2.70
11.25 2.81
5.41
2.38
6.51
2.50
7.61
2.62
8.72
2.74
10.04 2.89
10.92 2.98
12.03 3.10
5.54
2.33
6.68
2.45
7.81
2.57
8.94
2.69
10.30 2.83
11.20 2.92
12.33 3.04
4.91
2.52
5.91
2.64
6.91
2.77
7.91
2.90
9.11
3.05
9.92
3.16
10.92 3.28

18C
TC
PI
kW
kW
4.60
1.96
5.57
2.06
6.53
2.16
7.49
2.26
8.65
2.38
9.42
2.46
10.38 2.56
5.04
2.16
6.10
2.27
7.16
2.38
8.21
2.49
9.48
2.62
10.32 2.70
11.38 2.81
5.41
2.32
6.54
2.44
7.67
2.56
8.80
2.67
10.16 2.81
11.06 2.91
12.19 3.02
3.73
1.78
4.52
1.86
5.30
1.95
6.08
2.04
7.02
2.15
7.64
2.22
8.42
2.31
4.45
2.18
5.38
2.29
6.31
2.40
7.24
2.51
8.35
2.65
9.10
2.73
10.03 2.84
4.93
2.18
5.96
2.29
7.00
2.40
8.03
2.50
9.27
2.64
10.09 2.72
11.12 2.83
5.27
2.41
6.37
2.53
7.48
2.65
8.58
2.77
9.90
2.91
10.79 3.01
11.89 3.13
5.41
2.36
6.54
2.47
7.67
2.59
8.80
2.71
10.16 2.85
11.06 2.95
12.19 3.07
4.79
2.54
5.79
2.67
6.79
2.80
7.79
2.93
8.99
3.08
9.79
3.18
10.80 3.31

Indoor air temp.:CDB


20C
21C
TC
PI
TC
PI
kW
kW
kW
kW
4.48
1.98
4.43
2.00
5.45
2.08
5.39
2.09
6.41
2.18
6.35
2.19
7.37
2.28
7.32
2.29
8.53
2.40
8.47
2.41
9.30
2.48
9.24
2.49
10.26 2.58 10.20 2.59
4.92
2.18
4.85
2.20
5.97
2.29
5.91
2.30
7.03
2.40
6.96
2.41
8.08
2.51
8.02
2.52
9.35
2.64
9.29
2.65
10.19 2.73 10.13 2.74
11.25 2.84 11.19 2.85
5.27
2.35
5.20
2.36
6.40
2.47
6.33
2.48
7.53
2.58
7.46
2.60
8.66
2.70
8.59
2.71
10.02 2.84
9.95
2.85
10.93 2.93 10.86 2.95
12.06 3.05 11.99 3.06
3.64
1.79
3.59
1.80
4.42
1.88
4.37
1.89
5.20
1.97
5.15
1.98
5.98
2.06
5.93
2.07
6.92
2.17
6.87
2.18
7.55
2.24
7.50
2.25
8.33
2.33
8.28
2.34
4.33
2.21
4.28
2.22
5.26
2.32
5.21
2.33
6.19
2.43
6.14
2.44
7.12
2.54
7.07
2.55
8.24
2.67
8.18
2.68
8.98
2.76
8.93
2.77
9.91
2.87
9.86
2.88
4.81
2.20
4.74
2.21
5.84
2.31
5.77
2.32
6.87
2.42
6.81
2.43
7.90
2.53
7.84
2.54
9.14
2.66
9.08
2.67
9.97
2.75
9.90
2.76
11.00 2.86 10.93 2.87
5.14
2.43
5.07
2.44
6.24
2.55
6.17
2.57
7.34
2.67
7.28
2.69
8.45
2.79
8.38
2.81
9.77
2.94
9.70
2.95
10.65 3.04 10.59 3.05
11.76 3.16 11.69 3.17
5.27
2.38
5.20
2.39
6.40
2.50
6.33
2.51
7.53
2.62
7.46
2.63
8.66
2.74
8.59
2.75
10.02 2.88
9.95
2.89
10.93 2.97 10.86 2.99
12.06 3.09 11.99 3.11
4.66
2.57
4.60
2.59
5.66
2.70
5.60
2.71
6.67
2.83
6.61
2.84
7.67
2.96
7.61
2.97
8.87
3.11
8.81
3.12
9.67
3.21
9.61
3.23
10.37 3.13 10.07 2.99

22C
TC
PI
kW
kW
4.37
2.01
5.33
2.11
6.29
2.20
7.26
2.30
8.41
2.42
9.18
2.50
10.15 2.60
4.79
2.21
5.84
2.32
6.90
2.42
7.95
2.53
9.22
2.66
10.07 2.75
11.12 2.86
5.13
2.37
6.26
2.49
7.39
2.61
8.52
2.73
9.88
2.87
10.79 2.96
11.92 3.08
3.54
1.81
4.32
1.90
5.11
1.99
5.89
2.08
6.82
2.19
7.45
2.26
8.23
2.35
4.22
2.23
5.15
2.34
6.08
2.45
7.01
2.56
8.13
2.69
8.87
2.78
9.63
2.78
4.68
2.22
5.71
2.33
6.74
2.44
7.78
2.55
9.01
2.68
9.84
2.77
10.87 2.88
5.00
2.46
6.10
2.58
7.21
2.70
8.31
2.82
9.64
2.97
10.52 3.06
11.62 3.18
5.13
2.41
6.26
2.53
7.39
2.65
8.52
2.76
9.88
2.91
10.79 3.00
11.92 3.12
4.54
2.60
5.54
2.73
6.54
2.86
7.55
2.98
8.75
3.14
9.55
3.24
9.78
2.85

24C
TC
PI
kW
kW
4.25
2.03
5.21
2.13
6.18
2.23
7.14
2.32
8.29
2.44
9.07
2.52
10.03 2.62
4.66
2.23
5.71
2.34
6.77
2.45
7.82
2.56
9.09
2.69
9.94
2.77
10.99 2.88
4.99
2.40
6.12
2.52
7.25
2.63
8.39
2.75
9.74
2.89
10.65 2.98
11.78 3.10
3.45
1.83
4.23
1.92
5.01
2.01
5.79
2.10
6.73
2.21
7.35
2.28
8.14
2.37
4.10
2.26
5.04
2.37
5.97
2.48
6.90
2.59
8.01
2.72
8.76
2.81
9.04
2.53
4.55
2.25
5.58
2.36
6.62
2.47
7.65
2.58
8.89
2.71
9.71
2.80
10.75 2.91
4.87
2.48
5.97
2.61
7.07
2.73
8.18
2.85
9.50
2.99
10.38 3.09
11.49 3.21
4.99
2.43
6.12
2.55
7.25
2.67
8.39
2.79
9.74
2.93
10.65 3.03
11.78 3.15
4.42
2.63
5.42
2.76
6.42
2.88
7.42
3.01
8.63
3.17
9.18
3.08
9.18
2.59

SUPER MULTI NX E-Series Heat Pump

EDAU12-722

Combination
(Capacity)
3.5+5.0

3.5+6.0

3.5+7.1

5.0+5.0

5.0+6.0

5.0+7.1

6.0+6.0

6.0+7.1

7.1+7.1

Capacity Tables

Outdoor
air temp.
CWB
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0

SUPER MULTI NX E-Series Heat Pump

16C
TC
PI
kW
kW
5.39
2.32
6.49
2.44
7.59
2.56
8.69
2.68
10.01 2.82
10.89 2.91
11.99 3.03
5.53
2.31
6.66
2.42
7.79
2.54
8.92
2.66
10.28 2.80
11.18 2.89
12.31 3.01
5.55
2.25
6.68
2.36
7.82
2.48
8.95
2.59
10.31 2.73
11.21 2.82
12.35 2.94
5.68
2.23
6.84
2.35
8.00
2.46
9.16
2.57
10.55 2.71
11.48 2.80
12.64 2.91
5.71
2.22
6.87
2.33
8.03
2.44
9.20
2.56
10.59 2.69
11.53 2.78
12.69 2.89
5.72
2.21
6.89
2.32
8.06
2.43
9.22
2.55
10.63 2.68
11.56 2.77
12.73 2.88
5.73
2.25
6.90
2.36
8.06
2.48
9.23
2.59
10.64 2.73
11.57 2.82
12.74 2.94
5.74
2.24
6.92
2.36
8.09
2.47
9.26
2.58
10.67 2.72
11.60 2.81
12.78 2.93
5.76
2.18
6.94
2.30
8.11
2.41
9.29
2.52
10.70 2.65
11.64 2.74
12.81 2.85

18C
TC
PI
kW
kW
5.26
2.35
6.36
2.47
7.45
2.58
8.55
2.70
9.87
2.84
10.75 2.94
11.85 3.06
5.40
2.33
6.52
2.45
7.65
2.57
8.78
2.68
10.14 2.82
11.04 2.92
12.17 3.04
5.41
2.27
6.54
2.39
7.68
2.50
8.81
2.62
10.17 2.75
11.07 2.85
12.21 2.96
5.54
2.26
6.70
2.37
7.86
2.49
9.02
2.60
10.41 2.74
11.34 2.83
12.50 2.94
5.56
2.24
6.73
2.35
7.89
2.47
9.06
2.58
10.45 2.72
11.38 2.81
12.55 2.92
5.58
2.23
6.75
2.35
7.91
2.46
9.08
2.57
10.48 2.71
11.42 2.80
12.58 2.91
5.58
2.27
6.75
2.39
7.92
2.50
9.09
2.62
10.49 2.75
11.43 2.85
12.60 2.96
5.60
2.27
6.77
2.38
7.94
2.49
9.12
2.61
10.52 2.75
11.46 2.84
12.63 2.95
5.62
2.21
6.79
2.32
7.97
2.43
9.14
2.54
10.55 2.68
11.49 2.76
12.67 2.88

Indoor air temp.:CDB


20C
21C
TC
PI
TC
PI
kW
kW
kW
kW
5.12
2.37
5.05
2.39
6.22
2.49
6.15
2.50
7.32
2.61
7.25
2.62
8.42
2.73
8.35
2.74
9.74
2.87
9.67
2.88
10.62 2.96 10.55 2.98
11.72 3.08 11.65 3.10
5.26
2.36
5.19
2.37
6.39
2.47
6.32
2.49
7.52
2.59
7.45
2.60
8.64
2.71
8.58
2.72
10.00 2.85
9.93
2.86
10.90 2.94 10.83 2.96
12.03 3.06 11.96 3.07
5.27
2.30
5.20
2.31
6.41
2.41
6.34
2.43
7.54
2.53
7.47
2.54
8.67
2.64
8.60
2.66
10.03 2.78
9.96
2.79
10.94 2.87 10.87 2.88
12.07 2.99 12.00 3.00
5.40
2.28
5.33
2.30
6.56
2.40
6.49
2.41
7.72
2.51
7.65
2.52
8.88
2.62
8.81
2.64
10.27 2.76 10.20 2.77
11.20 2.85 11.13 2.86
12.36 2.96 12.29 2.98
5.42
2.27
5.35
2.28
6.58
2.38
6.51
2.39
7.75
2.49
7.68
2.50
8.91
2.60
8.84
2.62
10.31 2.74 10.24 2.75
11.24 2.83 11.17 2.84
12.41 2.94 12.33 2.96
5.44
2.26
5.36
2.27
6.60
2.37
6.53
2.38
7.77
2.48
7.70
2.49
8.94
2.60
8.87
2.61
10.34 2.73 10.27 2.74
11.27 2.82 11.20 2.83
12.44 2.93 12.37 2.94
5.44
2.30
5.37
2.31
6.61
2.41
6.54
2.43
7.78
2.53
7.71
2.54
8.95
2.64
8.88
2.66
10.35 2.78 10.28 2.79
11.28 2.87 11.21 2.88
12.45 2.99 12.38 3.00
5.46
2.29
5.39
2.30
6.63
2.40
6.56
2.42
7.80
2.52
7.73
2.53
8.97
2.63
8.90
2.65
10.38 2.77 10.31 2.78
11.32 2.86 11.25 2.87
12.49 2.98 12.42 2.99
5.47
2.23
5.40
2.25
6.65
2.34
6.58
2.36
7.82
2.46
7.75
2.47
9.00
2.57
8.93
2.58
10.41 2.70 10.34 2.71
11.35 2.79 11.28 2.80
12.53 2.90 12.45 2.91

22C
TC
PI
kW
kW
4.99
2.40
6.09
2.52
7.19
2.64
8.29
2.75
9.61
2.90
10.49 2.99
11.59 3.11
5.12
2.38
6.25
2.50
7.38
2.62
8.51
2.73
9.86
2.88
10.77 2.97
11.89 3.09
5.13
2.32
6.27
2.44
7.40
2.55
8.53
2.67
9.89
2.81
10.80 2.90
11.93 3.01
5.26
2.31
6.42
2.42
7.58
2.53
8.74
2.65
10.13 2.78
11.06 2.88
12.22 2.99
5.28
2.29
6.44
2.40
7.61
2.52
8.77
2.63
10.17 2.76
11.10 2.85
12.26 2.97
5.29
2.28
6.46
2.39
7.63
2.51
8.80
2.62
10.20 2.75
11.13 2.84
12.30 2.96
5.30
2.32
6.47
2.44
7.64
2.55
8.80
2.67
10.21 2.81
11.14 2.90
12.31 3.01
5.31
2.32
6.49
2.43
7.66
2.54
8.83
2.66
10.24 2.79
11.17 2.89
12.35 3.00
5.33
2.26
6.50
2.37
7.68
2.48
8.86
2.59
10.27 2.72
11.21 2.81
12.38 2.92

24C
TC
PI
kW
kW
4.85
2.43
5.95
2.54
7.05
2.66
8.15
2.78
9.47
2.92
10.35 3.02
11.45 3.13
4.98
2.41
6.11
2.53
7.24
2.64
8.37
2.76
9.72
2.90
10.63 3.00
11.76 3.11
5.00
2.35
6.13
2.46
7.26
2.58
8.39
2.69
9.75
2.83
10.66 2.92
11.79 3.04
5.12
2.33
6.28
2.45
7.44
2.56
8.59
2.67
9.99
2.81
10.91 2.90
12.07 3.01
5.14
2.32
6.30
2.43
7.46
2.54
8.63
2.65
10.03 2.79
10.96 2.88
12.12 2.99
5.15
2.31
6.32
2.42
7.49
2.53
8.65
2.64
10.05 2.78
10.99 2.87
12.16 2.98
5.16
2.35
6.32
2.46
7.49
2.58
8.66
2.69
10.06 2.83
11.00 2.92
12.17 3.04
5.17
2.34
6.34
2.45
7.51
2.57
8.69
2.68
10.09 2.82
11.03 2.91
12.20 3.03
5.19
2.28
6.36
2.39
7.54
2.50
8.71
2.62
10.12 2.75
11.06 2.84
12.24 2.95

155

Capacity Tables

Combination
(Capacity)
2.0+2.0+2.0

2.0+2.0+2.5

2.0+2.0+3.5

2.0+2.0+5.0

2.0+2.0+6.0

2.0+2.0+7.1

2.0+2.5+2.5

2.0+2.5+3.5

2.0+2.5+5.0

156

EDAU12-722

Outdoor
air temp.
CWB
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0

16C
TC
PI
kW
kW
4.45
1.76
5.36
1.84
6.27
1.93
7.18
2.02
8.27
2.13
9.00
2.20
9.91
2.29
4.78
1.91
5.76
2.01
6.73
2.10
7.71
2.20
8.88
2.32
9.66
2.40
10.63 2.49
5.18
2.14
6.24
2.24
7.30
2.35
8.36
2.46
9.63
2.59
10.48 2.68
11.53 2.79
5.71
2.22
6.88
2.33
8.04
2.44
9.21
2.56
10.60 2.69
11.54 2.78
12.70 2.89
5.73
2.20
6.90
2.31
8.06
2.42
9.23
2.54
10.64 2.67
11.57 2.76
12.74 2.87
5.75
2.19
6.92
2.30
8.10
2.42
9.27
2.53
10.68 2.66
11.62 2.75
12.79 2.86
4.78
1.89
5.76
1.99
6.73
2.09
7.71
2.18
8.88
2.30
9.66
2.37
10.63 2.47
5.18
2.11
6.24
2.22
7.30
2.33
8.36
2.43
9.63
2.56
10.48 2.65
11.53 2.76
5.71
2.22
6.88
2.33
8.04
2.44
9.21
2.56
10.60 2.69
11.54 2.78
12.70 2.89

18C
TC
PI
kW
kW
4.34
1.78
5.25
1.86
6.16
1.95
7.07
2.04
8.16
2.15
8.89
2.22
9.80
2.31
4.66
1.93
5.64
2.03
6.61
2.12
7.59
2.22
8.76
2.34
9.54
2.42
10.52 2.51
5.06
2.16
6.11
2.27
7.17
2.38
8.23
2.49
9.50
2.62
10.35 2.70
11.40 2.81
5.57
2.24
6.73
2.35
7.90
2.47
9.06
2.58
10.46 2.72
11.39 2.81
12.56 2.92
5.58
2.23
6.75
2.34
7.92
2.45
9.09
2.56
10.49 2.70
11.43 2.79
12.60 2.90
5.61
2.22
6.78
2.33
7.95
2.44
9.13
2.55
10.53 2.69
11.47 2.77
12.65 2.89
4.66
1.91
5.64
2.01
6.61
2.11
7.59
2.20
8.76
2.32
9.54
2.40
10.52 2.49
5.06
2.14
6.11
2.24
7.17
2.35
8.23
2.46
9.50
2.59
10.35 2.67
11.40 2.78
5.57
2.24
6.73
2.35
7.90
2.47
9.06
2.58
10.46 2.72
11.39 2.81
12.56 2.92

Indoor air temp.:CDB


20C
21C
TC
PI
TC
PI
kW
kW
kW
kW
4.23
1.79
4.18
1.80
5.14
1.88
5.09
1.89
6.05
1.97
5.99
1.98
6.96
2.06
6.90
2.07
8.05
2.17
7.99
2.18
8.78
2.24
8.72
2.25
9.69
2.33
9.63
2.34
4.54
1.95
4.48
1.96
5.52
2.05
5.46
2.06
6.49
2.15
6.43
2.16
7.47
2.24
7.41
2.25
8.64
2.36
8.58
2.37
9.42
2.44
9.36
2.45
10.40 2.53 10.34 2.55
4.93
2.18
4.86
2.20
5.98
2.29
5.92
2.30
7.04
2.40
6.98
2.41
8.10
2.51
8.04
2.52
9.37
2.64
9.31
2.65
10.22 2.73 10.15 2.74
11.27 2.84 11.21 2.85
5.43
2.27
5.35
2.28
6.59
2.38
6.52
2.39
7.76
2.49
7.69
2.50
8.92
2.60
8.85
2.62
10.32 2.74 10.25 2.75
11.25 2.83 11.18 2.84
12.42 2.94 12.35 2.96
5.44
2.25
5.37
2.26
6.61
2.36
6.54
2.37
7.78
2.47
7.71
2.49
8.95
2.59
8.88
2.60
10.35 2.72 10.28 2.73
11.28 2.81 11.21 2.82
12.45 2.92 12.38 2.93
5.46
2.24
5.39
2.25
6.64
2.35
6.56
2.37
7.81
2.46
7.74
2.48
8.98
2.58
8.91
2.59
10.39 2.71 10.32 2.72
11.33 2.80 11.26 2.81
12.50 2.91 12.43 2.92
4.54
1.94
4.48
1.95
5.52
2.03
5.46
2.04
6.49
2.13
6.43
2.14
7.47
2.22
7.41
2.23
8.64
2.34
8.58
2.35
9.42
2.42
9.36
2.43
10.40 2.51 10.34 2.52
4.93
2.16
4.86
2.17
5.98
2.27
5.92
2.28
7.04
2.37
6.98
2.39
8.10
2.48
8.04
2.49
9.37
2.61
9.31
2.62
10.22 2.70 10.15 2.71
11.27 2.80 11.21 2.82
5.43
2.27
5.35
2.28
6.59
2.38
6.52
2.39
7.76
2.49
7.69
2.50
8.92
2.60
8.85
2.62
10.32 2.74 10.25 2.75
11.25 2.83 11.18 2.84
12.42 2.94 12.35 2.96

22C
TC
PI
kW
kW
4.12
1.81
5.03
1.90
5.94
1.99
6.85
2.08
7.94
2.19
8.67
2.26
9.58
2.35
4.42
1.97
5.40
2.07
6.37
2.17
7.35
2.26
8.52
2.38
9.30
2.46
10.28 2.56
4.80
2.21
5.85
2.32
6.91
2.42
7.97
2.53
9.24
2.66
10.09 2.75
11.15 2.86
5.28
2.29
6.45
2.40
7.61
2.52
8.78
2.63
10.18 2.76
11.11 2.85
12.28 2.97
5.30
2.27
6.47
2.39
7.64
2.50
8.80
2.61
10.21 2.74
11.14 2.83
12.31 2.95
5.32
2.27
6.49
2.38
7.67
2.49
8.84
2.60
10.25 2.73
11.19 2.82
12.36 2.94
4.42
1.96
5.40
2.05
6.37
2.15
7.35
2.25
8.52
2.36
9.30
2.44
10.28 2.53
4.80
2.18
5.85
2.29
6.91
2.40
7.97
2.50
9.24
2.63
10.09 2.72
11.15 2.83
5.28
2.29
6.45
2.40
7.61
2.52
8.78
2.63
10.18 2.76
11.11 2.85
12.28 2.97

24C
TC
PI
kW
kW
4.01
1.83
4.92
1.92
5.83
2.01
6.74
2.10
7.83
2.21
8.55
2.28
9.46
2.37
4.30
1.99
5.28
2.09
6.26
2.19
7.23
2.29
8.40
2.40
9.18
2.48
10.16 2.58
4.67
2.23
5.73
2.34
6.78
2.45
7.84
2.56
9.11
2.69
9.96
2.77
11.02 2.88
5.14
2.32
6.31
2.43
7.47
2.54
8.64
2.65
10.04 2.79
10.97 2.88
12.13 2.99
5.16
2.30
6.32
2.41
7.49
2.52
8.66
2.63
10.06 2.77
11.00 2.86
12.17 2.97
5.18
2.29
6.35
2.40
7.52
2.51
8.70
2.62
10.10 2.76
11.04 2.85
12.21 2.96
4.30
1.98
5.28
2.07
6.26
2.17
7.23
2.27
8.40
2.38
9.18
2.46
10.16 2.56
4.67
2.21
5.73
2.31
6.78
2.42
7.84
2.53
9.11
2.66
9.96
2.74
11.02 2.85
5.14
2.32
6.31
2.43
7.47
2.54
8.64
2.65
10.04 2.79
10.97 2.88
12.13 2.99

SUPER MULTI NX E-Series Heat Pump

EDAU12-722

Combination
(Capacity)
2.0+2.5+6.0

2.0+2.5+7.1

2.0+3.5+3.5

2.0+3.5+5.0

2.0+3.5+6.0

2.0+3.5+7.1

2.0+5.0+5.0

2.0+5.0+6.0

2.0+5.0+7.1

Capacity Tables

Outdoor
air temp.
CWB
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0

SUPER MULTI NX E-Series Heat Pump

16C
TC
PI
kW
kW
5.73
2.20
6.90
2.31
8.06
2.42
9.23
2.54
10.64 2.67
11.57 2.76
12.74 2.87
5.75
2.19
6.92
2.30
8.10
2.42
9.27
2.53
10.68 2.66
11.62 2.75
12.79 2.86
5.54
2.26
6.67
2.37
7.80
2.49
8.93
2.60
10.29 2.74
11.19 2.83
12.32 2.95
5.71
2.22
6.88
2.33
8.04
2.44
9.21
2.56
10.60 2.69
11.54 2.78
12.70 2.89
5.73
2.20
6.90
2.31
8.07
2.42
9.24
2.54
10.65 2.67
11.58 2.76
12.75 2.87
5.75
2.19
6.92
2.30
8.10
2.42
9.27
2.53
10.68 2.66
11.62 2.75
12.79 2.86
5.89
2.16
7.09
2.27
8.29
2.38
9.49
2.49
10.93 2.62
11.89 2.71
13.10 2.82
5.90
2.15
7.11
2.26
8.31
2.37
9.52
2.48
10.96 2.61
11.93 2.70
13.13 2.81
5.93
2.14
7.14
2.24
8.35
2.35
9.55
2.46
11.01 2.59
11.97 2.68
13.18 2.79

18C
TC
PI
kW
kW
5.58
2.23
6.75
2.34
7.92
2.45
9.09
2.56
10.49 2.70
11.43 2.79
12.60 2.90
5.61
2.22
6.78
2.33
7.95
2.44
9.13
2.55
10.53 2.69
11.47 2.77
12.65 2.89
5.40
2.28
6.53
2.40
7.66
2.51
8.79
2.63
10.15 2.76
11.05 2.86
12.18 2.97
5.57
2.24
6.73
2.35
7.90
2.47
9.06
2.58
10.46 2.72
11.39 2.81
12.56 2.92
5.59
2.23
6.76
2.34
7.93
2.45
9.10
2.56
10.50 2.70
11.44 2.79
12.61 2.90
5.61
2.22
6.78
2.33
7.95
2.44
9.13
2.55
10.53 2.69
11.47 2.77
12.65 2.89
5.74
2.18
6.94
2.29
8.14
2.40
9.35
2.51
10.79 2.65
11.75 2.73
12.95 2.84
5.76
2.18
6.96
2.29
8.17
2.40
9.37
2.50
10.82 2.64
11.78 2.72
12.99 2.83
5.78
2.16
6.99
2.27
8.20
2.38
9.41
2.49
10.86 2.62
11.83 2.70
13.03 2.81

Indoor air temp.:CDB


20C
21C
TC
PI
TC
PI
kW
kW
kW
kW
5.44
2.25
5.37
2.26
6.61
2.36
6.54
2.37
7.78
2.47
7.71
2.49
8.95
2.59
8.88
2.60
10.35 2.72 10.28 2.73
11.28 2.81 11.21 2.82
12.45 2.92 12.38 2.93
5.46
2.24
5.39
2.25
6.64
2.35
6.56
2.37
7.81
2.46
7.74
2.48
8.98
2.58
8.91
2.59
10.39 2.71 10.32 2.72
11.33 2.80 11.26 2.81
12.50 2.91 12.43 2.92
5.26
2.31
5.19
2.32
6.39
2.42
6.32
2.43
7.52
2.54
7.45
2.55
8.65
2.65
8.58
2.66
10.01 2.79
9.94
2.80
10.91 2.88 10.85 2.89
12.04 3.00 11.98 3.01
5.43
2.27
5.35
2.28
6.59
2.38
6.52
2.39
7.76
2.49
7.69
2.50
8.92
2.60
8.85
2.62
10.32 2.74 10.25 2.75
11.25 2.83 11.18 2.84
12.42 2.94 12.35 2.96
5.45
2.25
5.38
2.26
6.62
2.36
6.55
2.37
7.79
2.47
7.71
2.49
8.96
2.59
8.88
2.60
10.36 2.72 10.29 2.73
11.30 2.81 11.22 2.82
12.47 2.92 12.39 2.93
5.46
2.24
5.39
2.25
6.64
2.35
6.56
2.37
7.81
2.46
7.74
2.48
8.98
2.58
8.91
2.59
10.39 2.71 10.32 2.72
11.33 2.80 11.26 2.81
12.50 2.91 12.43 2.92
5.59
2.21
5.52
2.22
6.80
2.32
6.72
2.33
8.00
2.43
7.92
2.44
9.20
2.54
9.12
2.55
10.64 2.67 10.57 2.68
11.60 2.76 11.53 2.77
12.80 2.87 12.73 2.88
5.61
2.20
5.54
2.21
6.81
2.31
6.74
2.32
8.02
2.42
7.95
2.43
9.22
2.53
9.15
2.54
10.67 2.66 10.60 2.67
11.63 2.75 11.56 2.76
12.84 2.86 12.77 2.87
5.63
2.18
5.56
2.20
6.84
2.29
6.77
2.30
8.05
2.40
7.98
2.41
9.26
2.51
9.18
2.52
10.71 2.64 10.64 2.65
11.68 2.73 11.60 2.74
12.89 2.84 12.81 2.85

22C
TC
PI
kW
kW
5.30
2.27
6.47
2.39
7.64
2.50
8.80
2.61
10.21 2.74
11.14 2.83
12.31 2.95
5.32
2.27
6.49
2.38
7.67
2.49
8.84
2.60
10.25 2.73
11.19 2.82
12.36 2.94
5.12
2.33
6.25
2.45
7.39
2.56
8.52
2.68
9.87
2.82
10.78 2.91
11.91 3.02
5.28
2.29
6.45
2.40
7.61
2.52
8.78
2.63
10.18 2.76
11.11 2.85
12.28 2.97
5.30
2.27
6.47
2.39
7.64
2.50
8.81
2.61
10.22 2.74
11.15 2.83
12.32 2.95
5.32
2.27
6.49
2.38
7.67
2.49
8.84
2.60
10.25 2.73
11.19 2.82
12.36 2.94
5.45
2.23
6.65
2.34
7.85
2.45
9.05
2.56
10.49 2.69
11.45 2.78
12.66 2.89
5.46
2.22
6.67
2.33
7.87
2.44
9.08
2.55
10.52 2.68
11.49 2.77
12.69 2.88
5.48
2.21
6.69
2.32
7.90
2.42
9.11
2.53
10.56 2.66
11.53 2.75
12.74 2.86

24C
TC
PI
kW
kW
5.16
2.30
6.32
2.41
7.49
2.52
8.66
2.63
10.06 2.77
11.00 2.86
12.17 2.97
5.18
2.29
6.35
2.40
7.52
2.51
8.70
2.62
10.10 2.76
11.04 2.85
12.21 2.96
4.99
2.36
6.12
2.47
7.25
2.59
8.38
2.70
9.73
2.84
10.64 2.93
11.77 3.05
5.14
2.32
6.31
2.43
7.47
2.54
8.64
2.65
10.04 2.79
10.97 2.88
12.13 2.99
5.16
2.30
6.33
2.41
7.50
2.52
8.67
2.63
10.07 2.77
11.01 2.86
12.18 2.97
5.18
2.29
6.35
2.40
7.52
2.51
8.70
2.62
10.10 2.76
11.04 2.85
12.21 2.96
5.30
2.26
6.50
2.37
7.70
2.48
8.90
2.59
10.35 2.72
11.31 2.81
12.51 2.92
5.32
2.25
6.52
2.36
7.72
2.47
8.93
2.58
10.38 2.71
11.34 2.80
12.54 2.91
5.33
2.23
6.54
2.34
7.75
2.45
8.96
2.56
10.41 2.69
11.38 2.77
12.59 2.88

157

Capacity Tables

Combination
(Capacity)
2.0+6.0+6.0

2.5+2.5+2.5

2.5+2.5+3.5

2.5+2.5+5.0

2.5+2.5+6.0

2.5+2.5+7.1

2.5+3.5+3.5

2.5+3.5+5.0

2.5+3.5+6.0

158

EDAU12-722

Outdoor
air temp.
CWB
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0

16C
TC
PI
kW
kW
5.93
2.14
7.14
2.24
8.35
2.35
9.55
2.46
11.01 2.59
11.97 2.68
13.18 2.79
5.28
2.22
6.36
2.33
7.44
2.44
8.52
2.56
9.81
2.69
10.68 2.78
11.75 2.89
5.41
2.26
6.52
2.37
7.62
2.49
8.72
2.60
10.05 2.74
10.93 2.83
12.04 2.95
5.71
2.22
6.88
2.33
8.04
2.44
9.21
2.56
10.60 2.69
11.54 2.78
12.70 2.89
5.73
2.20
6.90
2.31
8.06
2.42
9.23
2.54
10.64 2.67
11.57 2.76
12.74 2.87
5.75
2.19
6.92
2.30
8.10
2.42
9.27
2.53
10.68 2.66
11.62 2.75
12.79 2.86
5.54
2.26
6.67
2.37
7.80
2.49
8.93
2.60
10.29 2.74
11.19 2.83
12.32 2.95
5.71
2.22
6.88
2.33
8.04
2.44
9.21
2.56
10.60 2.69
11.54 2.78
12.70 2.89
5.73
2.20
6.90
2.31
8.07
2.42
9.24
2.54
10.65 2.67
11.58 2.76
12.75 2.87

18C
TC
PI
kW
kW
5.78
2.16
6.99
2.27
8.20
2.38
9.41
2.49
10.86 2.62
11.83 2.70
13.03 2.81
5.15
2.24
6.23
2.35
7.31
2.47
8.39
2.58
9.68
2.72
10.54 2.81
11.62 2.92
5.28
2.28
6.38
2.40
7.49
2.51
8.59
2.63
9.92
2.76
10.80 2.86
11.90 2.97
5.57
2.24
6.73
2.35
7.90
2.47
9.06
2.58
10.46 2.72
11.39 2.81
12.56 2.92
5.58
2.23
6.75
2.34
7.92
2.45
9.09
2.56
10.49 2.70
11.43 2.79
12.60 2.90
5.61
2.22
6.78
2.33
7.95
2.44
9.13
2.55
10.53 2.69
11.47 2.77
12.65 2.89
5.40
2.28
6.53
2.40
7.66
2.51
8.79
2.63
10.15 2.76
11.05 2.86
12.18 2.97
5.57
2.24
6.73
2.35
7.90
2.47
9.06
2.58
10.46 2.72
11.39 2.81
12.56 2.92
5.59
2.23
6.76
2.34
7.93
2.45
9.10
2.56
10.50 2.70
11.44 2.79
12.61 2.90

Indoor air temp.:CDB


20C
21C
TC
PI
TC
PI
kW
kW
kW
kW
5.63
2.18
5.56
2.20
6.84
2.29
6.77
2.30
8.05
2.40
7.98
2.41
9.26
2.51
9.18
2.52
10.71 2.64 10.64 2.65
11.68 2.73 11.60 2.74
12.89 2.84 12.81 2.85
5.02
2.27
4.95
2.28
6.10
2.38
6.03
2.39
7.18
2.49
7.11
2.50
8.26
2.60
8.19
2.62
9.55
2.74
9.48
2.75
10.41 2.83 10.35 2.84
11.49 2.94 11.43 2.96
5.14
2.31
5.07
2.32
6.25
2.42
6.18
2.43
7.35
2.54
7.28
2.55
8.45
2.65
8.39
2.66
9.78
2.79
9.71
2.80
10.66 2.88 10.60 2.89
11.77 3.00 11.70 3.01
5.43
2.27
5.35
2.28
6.59
2.38
6.52
2.39
7.76
2.49
7.69
2.50
8.92
2.60
8.85
2.62
10.32 2.74 10.25 2.75
11.25 2.83 11.18 2.84
12.42 2.94 12.35 2.96
5.44
2.25
5.37
2.26
6.61
2.36
6.54
2.37
7.78
2.47
7.71
2.49
8.95
2.59
8.88
2.60
10.35 2.72 10.28 2.73
11.28 2.81 11.21 2.82
12.45 2.92 12.38 2.93
5.46
2.24
5.39
2.25
6.64
2.35
6.56
2.37
7.81
2.46
7.74
2.48
8.98
2.58
8.91
2.59
10.39 2.71 10.32 2.72
11.33 2.80 11.26 2.81
12.50 2.91 12.43 2.92
5.26
2.31
5.19
2.32
6.39
2.42
6.32
2.43
7.52
2.54
7.45
2.55
8.65
2.65
8.58
2.66
10.01 2.79
9.94
2.80
10.91 2.88 10.85 2.89
12.04 3.00 11.98 3.01
5.43
2.27
5.35
2.28
6.59
2.38
6.52
2.39
7.76
2.49
7.69
2.50
8.92
2.60
8.85
2.62
10.32 2.74 10.25 2.75
11.25 2.83 11.18 2.84
12.42 2.94 12.35 2.96
5.45
2.25
5.38
2.26
6.62
2.36
6.55
2.37
7.79
2.47
7.71
2.49
8.96
2.59
8.88
2.60
10.36 2.72 10.29 2.73
11.30 2.81 11.22 2.82
12.47 2.92 12.39 2.93

22C
TC
PI
kW
kW
5.48
2.21
6.69
2.32
7.90
2.42
9.11
2.53
10.56 2.66
11.53 2.75
12.74 2.86
4.89
2.29
5.97
2.40
7.05
2.52
8.12
2.63
9.42
2.76
10.28 2.85
11.36 2.97
5.01
2.33
6.11
2.45
7.22
2.56
8.32
2.68
9.64
2.82
10.53 2.91
11.63 3.02
5.28
2.29
6.45
2.40
7.61
2.52
8.78
2.63
10.18 2.76
11.11 2.85
12.28 2.97
5.30
2.27
6.47
2.39
7.64
2.50
8.80
2.61
10.21 2.74
11.14 2.83
12.31 2.95
5.32
2.27
6.49
2.38
7.67
2.49
8.84
2.60
10.25 2.73
11.19 2.82
12.36 2.94
5.12
2.33
6.25
2.45
7.39
2.56
8.52
2.68
9.87
2.82
10.78 2.91
11.91 3.02
5.28
2.29
6.45
2.40
7.61
2.52
8.78
2.63
10.18 2.76
11.11 2.85
12.28 2.97
5.30
2.27
6.47
2.39
7.64
2.50
8.81
2.61
10.22 2.74
11.15 2.83
12.32 2.95

24C
TC
PI
kW
kW
5.33
2.23
6.54
2.34
7.75
2.45
8.96
2.56
10.41 2.69
11.38 2.77
12.59 2.88
4.76
2.32
5.84
2.43
6.91
2.54
7.99
2.65
9.29
2.79
10.15 2.88
11.23 2.99
4.87
2.36
5.98
2.47
7.08
2.59
8.18
2.70
9.51
2.84
10.39 2.93
11.50 3.05
5.14
2.32
6.31
2.43
7.47
2.54
8.64
2.65
10.04 2.79
10.97 2.88
12.13 2.99
5.16
2.30
6.32
2.41
7.49
2.52
8.66
2.63
10.06 2.77
11.00 2.86
12.17 2.97
5.18
2.29
6.35
2.40
7.52
2.51
8.70
2.62
10.10 2.76
11.04 2.85
12.21 2.96
4.99
2.36
6.12
2.47
7.25
2.59
8.38
2.70
9.73
2.84
10.64 2.93
11.77 3.05
5.14
2.32
6.31
2.43
7.47
2.54
8.64
2.65
10.04 2.79
10.97 2.88
12.13 2.99
5.16
2.30
6.33
2.41
7.50
2.52
8.67
2.63
10.07 2.77
11.01 2.86
12.18 2.97

SUPER MULTI NX E-Series Heat Pump

EDAU12-722

Combination
(Capacity)
2.5+3.5+7.1

2.5+5.0+5.0

2.5+5.0+6.0

2.5+6.0+6.0

3.5+3.5+3.5

3.5+3.5+5.0

3.5+3.5+6.0

3.5+3.5+7.1

3.5+5.0+5.0

Capacity Tables

Outdoor
air temp.
CWB
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0

SUPER MULTI NX E-Series Heat Pump

16C
TC
PI
kW
kW
5.75
2.19
6.92
2.30
8.10
2.42
9.27
2.53
10.68 2.66
11.62 2.75
12.79 2.86
5.89
2.16
7.09
2.27
8.29
2.38
9.49
2.49
10.93 2.62
11.89 2.71
13.10 2.82
5.90
2.15
7.11
2.26
8.31
2.37
9.52
2.48
10.96 2.61
11.93 2.70
13.13 2.81
5.93
2.14
7.14
2.24
8.35
2.35
9.55
2.46
11.01 2.59
11.97 2.68
13.18 2.79
5.54
2.26
6.68
2.37
7.81
2.49
8.94
2.60
10.30 2.74
11.20 2.83
12.33 2.95
5.72
2.21
6.88
2.32
8.05
2.43
9.22
2.55
10.62 2.68
11.55 2.77
12.71 2.88
5.74
2.20
6.91
2.31
8.08
2.42
9.25
2.54
10.66 2.67
11.59 2.76
12.76 2.87
5.75
2.19
6.93
2.30
8.10
2.42
9.28
2.53
10.69 2.66
11.63 2.75
12.80 2.86
5.89
2.16
7.09
2.27
8.29
2.38
9.49
2.49
10.93 2.62
11.89 2.71
13.10 2.82

18C
TC
PI
kW
kW
5.61
2.22
6.78
2.33
7.95
2.44
9.13
2.55
10.53 2.69
11.47 2.77
12.65 2.89
5.74
2.18
6.94
2.29
8.14
2.40
9.35
2.51
10.79 2.65
11.75 2.73
12.95 2.84
5.76
2.18
6.96
2.29
8.17
2.40
9.37
2.50
10.82 2.64
11.78 2.72
12.99 2.83
5.78
2.16
6.99
2.27
8.20
2.38
9.41
2.49
10.86 2.62
11.83 2.70
13.03 2.81
5.41
2.28
6.54
2.40
7.67
2.51
8.80
2.63
10.16 2.76
11.06 2.86
12.19 2.97
5.57
2.23
6.74
2.35
7.91
2.46
9.07
2.57
10.47 2.71
11.41 2.80
12.57 2.91
5.60
2.23
6.77
2.34
7.94
2.45
9.11
2.56
10.51 2.70
11.45 2.79
12.62 2.90
5.61
2.22
6.79
2.33
7.96
2.44
9.13
2.55
10.54 2.69
11.48 2.77
12.66 2.89
5.74
2.18
6.94
2.29
8.14
2.40
9.35
2.51
10.79 2.65
11.75 2.73
12.95 2.84

Indoor air temp.:CDB


20C
21C
TC
PI
TC
PI
kW
kW
kW
kW
5.46
2.24
5.39
2.25
6.64
2.35
6.56
2.37
7.81
2.46
7.74
2.48
8.98
2.58
8.91
2.59
10.39 2.71 10.32 2.72
11.33 2.80 11.26 2.81
12.50 2.91 12.43 2.92
5.59
2.21
5.52
2.22
6.80
2.32
6.72
2.33
8.00
2.43
7.92
2.44
9.20
2.54
9.12
2.55
10.64 2.67 10.57 2.68
11.60 2.76 11.53 2.77
12.80 2.87 12.73 2.88
5.61
2.20
5.54
2.21
6.81
2.31
6.74
2.32
8.02
2.42
7.95
2.43
9.22
2.53
9.15
2.54
10.67 2.66 10.60 2.67
11.63 2.75 11.56 2.76
12.84 2.86 12.77 2.87
5.63
2.18
5.56
2.20
6.84
2.29
6.77
2.30
8.05
2.40
7.98
2.41
9.26
2.51
9.18
2.52
10.71 2.64 10.64 2.65
11.68 2.73 11.60 2.74
12.89 2.84 12.81 2.85
5.27
2.31
5.20
2.32
6.40
2.42
6.33
2.43
7.53
2.54
7.46
2.55
8.66
2.65
8.59
2.66
10.02 2.79
9.95
2.80
10.93 2.88 10.86 2.89
12.06 3.00 11.99 3.01
5.43
2.26
5.36
2.27
6.60
2.37
6.53
2.38
7.76
2.48
7.69
2.49
8.93
2.60
8.86
2.61
10.33 2.73 10.26 2.74
11.26 2.82 11.19 2.83
12.43 2.93 12.36 2.94
5.45
2.25
5.38
2.26
6.62
2.36
6.55
2.37
7.79
2.47
7.72
2.49
8.96
2.59
8.89
2.60
10.37 2.72 10.30 2.73
11.31 2.81 11.24 2.82
12.48 2.92 12.41 2.93
5.47
2.24
5.40
2.25
6.64
2.35
6.57
2.37
7.82
2.46
7.74
2.48
8.99
2.58
8.92
2.59
10.40 2.71 10.33 2.72
11.34 2.80 11.27 2.81
12.51 2.91 12.44 2.92
5.59
2.21
5.52
2.22
6.80
2.32
6.72
2.33
8.00
2.43
7.92
2.44
9.20
2.54
9.12
2.55
10.64 2.67 10.57 2.68
11.60 2.76 11.53 2.77
12.80 2.87 12.73 2.88

22C
TC
PI
kW
kW
5.32
2.27
6.49
2.38
7.67
2.49
8.84
2.60
10.25 2.73
11.19 2.82
12.36 2.94
5.45
2.23
6.65
2.34
7.85
2.45
9.05
2.56
10.49 2.69
11.45 2.78
12.66 2.89
5.46
2.22
6.67
2.33
7.87
2.44
9.08
2.55
10.52 2.68
11.49 2.77
12.69 2.88
5.48
2.21
6.69
2.32
7.90
2.42
9.11
2.53
10.56 2.66
11.53 2.75
12.74 2.86
5.13
2.33
6.26
2.45
7.39
2.56
8.52
2.68
9.88
2.82
10.79 2.91
11.92 3.02
5.29
2.28
6.45
2.39
7.62
2.51
8.79
2.62
10.19 2.75
11.12 2.84
12.29 2.96
5.31
2.27
6.48
2.39
7.65
2.50
8.82
2.61
10.23 2.74
11.16 2.83
12.33 2.95
5.32
2.27
6.50
2.38
7.67
2.49
8.85
2.60
10.26 2.73
11.20 2.82
12.37 2.94
5.45
2.23
6.65
2.34
7.85
2.45
9.05
2.56
10.49 2.69
11.45 2.78
12.66 2.89

24C
TC
PI
kW
kW
5.18
2.29
6.35
2.40
7.52
2.51
8.70
2.62
10.10 2.76
11.04 2.85
12.21 2.96
5.30
2.26
6.50
2.37
7.70
2.48
8.90
2.59
10.35 2.72
11.31 2.81
12.51 2.92
5.32
2.25
6.52
2.36
7.72
2.47
8.93
2.58
10.38 2.71
11.34 2.80
12.54 2.91
5.33
2.23
6.54
2.34
7.75
2.45
8.96
2.56
10.41 2.69
11.38 2.77
12.59 2.88
4.99
2.36
6.12
2.47
7.25
2.59
8.39
2.70
9.74
2.84
10.65 2.93
11.78 3.05
5.15
2.31
6.31
2.42
7.48
2.53
8.65
2.64
10.04 2.78
10.98 2.87
12.14 2.98
5.17
2.30
6.34
2.41
7.51
2.52
8.68
2.63
10.08 2.77
11.02 2.86
12.19 2.97
5.18
2.29
6.35
2.40
7.53
2.51
8.70
2.62
10.11 2.76
11.05 2.85
12.23 2.96
5.30
2.26
6.50
2.37
7.70
2.48
8.90
2.59
10.35 2.72
11.31 2.81
12.51 2.92

159

Capacity Tables

Combination
(Capacity)
3.5+5.0+6.0

2.0+2.0+2.0+2.0

2.0+2.0+2.0+2.5

2.0+2.0+2.0+3.5

2.0+2.0+2.0+5.0

2.0+2.0+2.0+6.0

2.0+2.0+2.0+7.1

2.0+2.0+2.5+2.5

2.0+2.0+2.5+3.5

160

EDAU12-722

Outdoor
air temp.
CWB
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0

16C
TC
PI
kW
kW
5.91
2.14
7.12
2.25
8.32
2.36
9.53
2.47
10.97 2.60
11.94 2.69
13.15 2.80
5.23
2.03
6.30
2.13
7.36
2.24
8.43
2.34
9.71
2.46
10.56 2.55
11.63 2.65
5.31
2.03
6.40
2.13
7.48
2.24
8.56
2.34
9.87
2.46
10.73 2.55
11.82 2.65
5.74
2.20
6.91
2.31
8.08
2.42
9.25
2.54
10.66 2.67
11.59 2.76
12.76 2.87
5.91
2.14
7.12
2.25
8.32
2.36
9.53
2.47
10.97 2.60
11.94 2.69
13.15 2.80
5.93
2.14
7.14
2.24
8.35
2.35
9.56
2.46
11.02 2.59
11.98 2.68
13.19 2.79
5.95
2.13
7.16
2.24
8.38
2.34
9.59
2.45
11.05 2.58
12.02 2.67
13.23 2.78
5.73
2.20
6.90
2.31
8.07
2.42
9.24
2.54
10.65 2.67
11.58 2.76
12.75 2.87
5.74
2.20
6.91
2.31
8.08
2.42
9.25
2.54
10.66 2.67
11.59 2.76
12.76 2.87

18C
TC
PI
kW
kW
5.76
2.17
6.97
2.28
8.17
2.39
9.38
2.50
10.83 2.63
11.79 2.71
13.00 2.82
5.10
2.05
6.17
2.16
7.23
2.26
8.30
2.36
9.58
2.49
10.43 2.57
11.50 2.67
5.18
2.05
6.26
2.16
7.35
2.26
8.43
2.36
9.73
2.49
10.60 2.57
11.68 2.67
5.60
2.23
6.77
2.34
7.94
2.45
9.11
2.56
10.51 2.70
11.45 2.79
12.62 2.90
5.76
2.17
6.97
2.28
8.17
2.39
9.38
2.50
10.83 2.63
11.79 2.71
13.00 2.82
5.78
2.16
6.99
2.27
8.20
2.38
9.42
2.49
10.87 2.62
11.84 2.70
13.05 2.81
5.80
2.15
7.01
2.26
8.23
2.37
9.44
2.48
10.90 2.61
11.87 2.69
13.08 2.80
5.59
2.23
6.76
2.34
7.93
2.45
9.10
2.56
10.50 2.70
11.44 2.79
12.61 2.90
5.60
2.23
6.77
2.34
7.94
2.45
9.11
2.56
10.51 2.70
11.45 2.79
12.62 2.90

Indoor air temp.:CDB


20C
21C
TC
PI
TC
PI
kW
kW
kW
kW
5.61
2.19
5.54
2.20
6.82
2.30
6.75
2.31
8.03
2.41
7.95
2.42
9.23
2.52
9.16
2.53
10.68 2.65 10.61 2.66
11.64 2.74 11.57 2.75
12.85 2.85 12.78 2.86
4.97
2.08
4.90
2.09
6.04
2.18
5.97
2.19
7.10
2.28
7.04
2.29
8.17
2.39
8.10
2.40
9.45
2.51
9.38
2.52
10.30 2.59 10.24 2.60
11.37 2.70 11.31 2.71
5.05
2.08
4.98
2.09
6.13
2.18
6.06
2.19
7.22
2.28
7.15
2.29
8.30
2.39
8.23
2.40
9.60
2.51
9.53
2.52
10.47 2.59 10.40 2.60
11.55 2.70 11.48 2.71
5.45
2.25
5.38
2.26
6.62
2.36
6.55
2.37
7.79
2.47
7.72
2.49
8.96
2.59
8.89
2.60
10.37 2.72 10.30 2.73
11.31 2.81 11.24 2.82
12.48 2.92 12.41 2.93
5.61
2.19
5.54
2.20
6.82
2.30
6.75
2.31
8.03
2.41
7.95
2.42
9.23
2.52
9.16
2.53
10.68 2.65 10.61 2.66
11.64 2.74 11.57 2.75
12.85 2.85 12.78 2.86
5.64
2.18
5.56
2.20
6.85
2.29
6.77
2.30
8.06
2.40
7.98
2.41
9.27
2.51
9.19
2.52
10.72 2.64 10.65 2.65
11.69 2.73 11.61 2.74
12.90 2.84 12.82 2.85
5.65
2.18
5.58
2.19
6.87
2.28
6.79
2.30
8.08
2.39
8.01
2.40
9.29
2.50
9.22
2.51
10.75 2.63 10.68 2.64
11.72 2.72 11.65 2.73
12.93 2.82 12.86 2.84
5.45
2.25
5.38
2.26
6.62
2.36
6.55
2.37
7.79
2.47
7.71
2.49
8.96
2.59
8.88
2.60
10.36 2.72 10.29 2.73
11.30 2.81 11.22 2.82
12.47 2.92 12.39 2.93
5.45
2.25
5.38
2.26
6.62
2.36
6.55
2.37
7.79
2.47
7.72
2.49
8.96
2.59
8.89
2.60
10.37 2.72 10.30 2.73
11.31 2.81 11.24 2.82
12.48 2.92 12.41 2.93

22C
TC
PI
kW
kW
5.47
2.22
6.67
2.32
7.88
2.43
9.09
2.54
10.53 2.67
11.50 2.76
12.70 2.87
4.84
2.10
5.90
2.20
6.97
2.31
8.04
2.41
9.32
2.53
10.17 2.62
11.24 2.72
4.91
2.10
6.00
2.20
7.08
2.31
8.17
2.41
9.47
2.53
10.33 2.62
11.42 2.72
5.31
2.27
6.48
2.39
7.65
2.50
8.82
2.61
10.23 2.74
11.16 2.83
12.33 2.95
5.47
2.22
6.67
2.32
7.88
2.43
9.09
2.54
10.53 2.67
11.50 2.76
12.70 2.87
5.49
2.21
6.70
2.32
7.91
2.42
9.12
2.53
10.57 2.66
11.54 2.75
12.75 2.86
5.50
2.20
6.72
2.31
7.93
2.42
9.14
2.52
10.60 2.65
11.57 2.74
12.79 2.85
5.30
2.27
6.47
2.39
7.64
2.50
8.81
2.61
10.22 2.74
11.15 2.83
12.32 2.95
5.31
2.27
6.48
2.39
7.65
2.50
8.82
2.61
10.23 2.74
11.16 2.83
12.33 2.95

24C
TC
PI
kW
kW
5.32
2.24
6.53
2.35
7.73
2.46
8.94
2.57
10.39 2.70
11.35 2.79
12.56 2.89
4.71
2.12
5.77
2.22
6.84
2.33
7.91
2.43
9.19
2.56
10.04 2.64
11.11 2.74
4.78
2.12
5.87
2.22
6.95
2.33
8.03
2.43
9.33
2.56
10.20 2.64
11.29 2.74
5.17
2.30
6.34
2.41
7.51
2.52
8.68
2.63
10.08 2.77
11.02 2.86
12.19 2.97
5.32
2.24
6.53
2.35
7.73
2.46
8.94
2.57
10.39 2.70
11.35 2.79
12.56 2.89
5.34
2.23
6.55
2.34
7.76
2.45
8.97
2.56
10.42 2.69
11.39 2.77
12.60 2.88
5.35
2.22
6.57
2.33
7.78
2.44
9.00
2.55
10.45 2.68
11.42 2.76
12.64 2.87
5.16
2.30
6.33
2.41
7.50
2.52
8.67
2.63
10.07 2.77
11.01 2.86
12.18 2.97
5.17
2.30
6.34
2.41
7.51
2.52
8.68
2.63
10.08 2.77
11.02 2.86
12.19 2.97

SUPER MULTI NX E-Series Heat Pump

EDAU12-722

Combination
(Capacity)
2.0+2.0+2.5+5.0

2.0+2.0+2.5+6.0

2.0+2.0+2.5+7.1

2.0+2.0+3.5+3.5

2.0+2.0+3.5+5.0

2.0+2.0+3.5+6.0

2.0+2.0+5.0+5.0

2.0+2.5+2.5+2.5

2.0+2.5+2.5+3.5

Capacity Tables

Outdoor
air temp.
CWB
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0

SUPER MULTI NX E-Series Heat Pump

16C
TC
PI
kW
kW
5.91
2.14
7.12
2.25
8.32
2.36
9.53
2.47
10.97 2.60
11.94 2.69
13.15 2.80
5.93
2.14
7.14
2.24
8.35
2.35
9.56
2.46
11.02 2.59
11.98 2.68
13.19 2.79
5.95
2.13
7.16
2.24
8.38
2.34
9.59
2.45
11.05 2.58
12.02 2.67
13.23 2.78
5.74
2.20
6.92
2.31
8.09
2.42
9.26
2.54
10.67 2.67
11.60 2.76
12.78 2.87
5.92
2.14
7.12
2.25
8.33
2.36
9.54
2.47
10.99 2.60
11.95 2.69
13.16 2.80
5.94
2.14
7.15
2.24
8.36
2.35
9.57
2.46
11.03 2.59
12.00 2.68
13.21 2.79
6.09
2.10
7.33
2.20
8.57
2.31
9.81
2.42
11.30 2.54
12.30 2.63
13.54 2.74
5.73
2.20
6.90
2.31
8.07
2.42
9.24
2.54
10.65 2.67
11.58 2.76
12.75 2.87
5.74
2.20
6.91
2.31
8.08
2.42
9.25
2.54
10.66 2.67
11.59 2.76
12.76 2.87

18C
TC
PI
kW
kW
5.76
2.17
6.97
2.28
8.17
2.39
9.38
2.50
10.83 2.63
11.79 2.71
13.00 2.82
5.78
2.16
6.99
2.27
8.20
2.38
9.42
2.49
10.87 2.62
11.84 2.70
13.05 2.81
5.80
2.15
7.01
2.26
8.23
2.37
9.44
2.48
10.90 2.61
11.87 2.69
13.08 2.80
5.60
2.23
6.77
2.34
7.94
2.45
9.12
2.56
10.52 2.70
11.46 2.79
12.63 2.90
5.77
2.17
6.97
2.28
8.18
2.39
9.39
2.50
10.84 2.63
11.80 2.71
13.01 2.82
5.79
2.16
7.00
2.27
8.21
2.38
9.42
2.49
10.88 2.62
11.85 2.70
13.06 2.81
5.94
2.12
7.18
2.23
8.42
2.33
9.66
2.44
11.15 2.57
12.15 2.65
13.39 2.76
5.59
2.23
6.76
2.34
7.93
2.45
9.10
2.56
10.50 2.70
11.44 2.79
12.61 2.90
5.60
2.23
6.77
2.34
7.94
2.45
9.11
2.56
10.51 2.70
11.45 2.79
12.62 2.90

Indoor air temp.:CDB


20C
21C
TC
PI
TC
PI
kW
kW
kW
kW
5.61
2.19
5.54
2.20
6.82
2.30
6.75
2.31
8.03
2.41
7.95
2.42
9.23
2.52
9.16
2.53
10.68 2.65 10.61 2.66
11.64 2.74 11.57 2.75
12.85 2.85 12.78 2.86
5.64
2.18
5.56
2.20
6.85
2.29
6.77
2.30
8.06
2.40
7.98
2.41
9.27
2.51
9.19
2.52
10.72 2.64 10.65 2.65
11.69 2.73 11.61 2.74
12.90 2.84 12.82 2.85
5.65
2.18
5.58
2.19
6.87
2.28
6.79
2.30
8.08
2.39
8.01
2.40
9.29
2.50
9.22
2.51
10.75 2.63 10.68 2.64
11.72 2.72 11.65 2.73
12.93 2.82 12.86 2.84
5.46
2.25
5.39
2.26
6.63
2.36
6.56
2.37
7.80
2.47
7.73
2.49
8.97
2.59
8.90
2.60
10.38 2.72 10.31 2.73
11.32 2.81 11.25 2.82
12.49 2.92 12.42 2.93
5.62
2.19
5.55
2.20
6.83
2.30
6.75
2.31
8.03
2.41
7.96
2.42
9.24
2.52
9.17
2.53
10.69 2.65 10.62 2.66
11.66 2.74 11.58 2.75
12.86 2.85 12.79 2.86
5.64
2.18
5.57
2.20
6.85
2.29
6.78
2.30
8.06
2.40
7.99
2.41
9.28
2.51
9.20
2.52
10.73 2.64 10.66 2.65
11.70 2.73 11.63 2.74
12.91 2.84 12.84 2.85
5.78
2.14
5.71
2.15
7.03
2.25
6.95
2.26
8.27
2.36
8.19
2.37
9.51
2.46
9.43
2.47
11.00 2.59 10.92 2.60
11.99 2.68 11.92 2.69
13.24 2.78 13.16 2.79
5.45
2.25
5.38
2.26
6.62
2.36
6.55
2.37
7.79
2.47
7.71
2.49
8.96
2.59
8.88
2.60
10.36 2.72 10.29 2.73
11.30 2.81 11.22 2.82
12.47 2.92 12.39 2.93
5.45
2.25
5.38
2.26
6.62
2.36
6.55
2.37
7.79
2.47
7.72
2.49
8.96
2.59
8.89
2.60
10.37 2.72 10.30 2.73
11.31 2.81 11.24 2.82
12.48 2.92 12.41 2.93

22C
TC
PI
kW
kW
5.47
2.22
6.67
2.32
7.88
2.43
9.09
2.54
10.53 2.67
11.50 2.76
12.70 2.87
5.49
2.21
6.70
2.32
7.91
2.42
9.12
2.53
10.57 2.66
11.54 2.75
12.75 2.86
5.50
2.20
6.72
2.31
7.93
2.42
9.14
2.52
10.60 2.65
11.57 2.74
12.79 2.85
5.31
2.27
6.49
2.39
7.66
2.50
8.83
2.61
10.24 2.74
11.17 2.83
12.35 2.95
5.47
2.22
6.68
2.32
7.89
2.43
9.09
2.54
10.54 2.67
11.51 2.76
12.72 2.87
5.49
2.21
6.70
2.32
7.92
2.42
9.13
2.53
10.58 2.66
11.55 2.75
12.76 2.86
5.63
2.17
6.87
2.27
8.12
2.38
9.36
2.49
10.85 2.61
11.84 2.70
13.08 2.81
5.30
2.27
6.47
2.39
7.64
2.50
8.81
2.61
10.22 2.74
11.15 2.83
12.32 2.95
5.31
2.27
6.48
2.39
7.65
2.50
8.82
2.61
10.23 2.74
11.16 2.83
12.33 2.95

24C
TC
PI
kW
kW
5.32
2.24
6.53
2.35
7.73
2.46
8.94
2.57
10.39 2.70
11.35 2.79
12.56 2.89
5.34
2.23
6.55
2.34
7.76
2.45
8.97
2.56
10.42 2.69
11.39 2.77
12.60 2.88
5.35
2.22
6.57
2.33
7.78
2.44
9.00
2.55
10.45 2.68
11.42 2.76
12.64 2.87
5.17
2.30
6.34
2.41
7.51
2.52
8.69
2.63
10.09 2.77
11.03 2.86
12.20 2.97
5.33
2.24
6.53
2.35
7.74
2.46
8.95
2.57
10.39 2.70
11.36 2.79
12.57 2.89
5.34
2.23
6.56
2.34
7.77
2.45
8.98
2.56
10.43 2.69
11.40 2.77
12.61 2.88
5.48
2.19
6.72
2.30
7.96
2.40
9.21
2.51
10.70 2.64
11.69 2.72
12.93 2.83
5.16
2.30
6.33
2.41
7.50
2.52
8.67
2.63
10.07 2.77
11.01 2.86
12.18 2.97
5.17
2.30
6.34
2.41
7.51
2.52
8.68
2.63
10.08 2.77
11.02 2.86
12.19 2.97

161

Capacity Tables

Combination
(Capacity)
2.0+2.5+2.5+5.0

2.0+2.5+2.5+6.0

2.0+2.5+2.5+7.1

2.0+2.5+3.5+3.5

2.0+2.5+3.5+5.0

2.0+2.5+3.5+6.0

2.0+2.5+5.0+5.0

2.0+3.5+3.5+3.5

2.0+3.5+3.5+5.0

162

EDAU12-722

Outdoor
air temp.
CWB
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0

16C
TC
PI
kW
kW
5.91
2.14
7.12
2.25
8.32
2.36
9.53
2.47
10.97 2.60
11.94 2.69
13.15 2.80
5.93
2.14
7.14
2.24
8.35
2.35
9.56
2.46
11.02 2.59
11.98 2.68
13.19 2.79
5.95
2.13
7.16
2.24
8.38
2.34
9.59
2.45
11.05 2.58
12.02 2.67
13.23 2.78
5.74
2.20
6.92
2.31
8.09
2.42
9.26
2.54
10.67 2.67
11.60 2.76
12.78 2.87
5.92
2.14
7.12
2.25
8.33
2.36
9.54
2.47
10.99 2.60
11.95 2.69
13.16 2.80
5.94
2.14
7.15
2.24
8.36
2.35
9.57
2.46
11.03 2.59
12.00 2.68
13.21 2.79
6.09
2.10
7.33
2.20
8.57
2.31
9.81
2.42
11.30 2.54
12.30 2.63
13.54 2.74
5.74
2.19
6.92
2.30
8.09
2.42
9.26
2.53
10.67 2.66
11.60 2.75
12.78 2.86
5.92
2.14
7.13
2.25
8.34
2.36
9.55
2.47
11.00 2.60
11.96 2.69
13.17 2.80

18C
TC
PI
kW
kW
5.76
2.17
6.97
2.28
8.17
2.39
9.38
2.50
10.83 2.63
11.79 2.71
13.00 2.82
5.78
2.16
6.99
2.27
8.20
2.38
9.42
2.49
10.87 2.62
11.84 2.70
13.05 2.81
5.80
2.15
7.01
2.26
8.23
2.37
9.44
2.48
10.90 2.61
11.87 2.69
13.08 2.80
5.60
2.23
6.77
2.34
7.94
2.45
9.12
2.56
10.52 2.70
11.46 2.79
12.63 2.90
5.77
2.17
6.97
2.28
8.18
2.39
9.39
2.50
10.84 2.63
11.80 2.71
13.01 2.82
5.79
2.16
7.00
2.27
8.21
2.38
9.42
2.49
10.88 2.62
11.85 2.70
13.06 2.81
5.94
2.12
7.18
2.23
8.42
2.33
9.66
2.44
11.15 2.57
12.15 2.65
13.39 2.76
5.60
2.22
6.77
2.33
7.94
2.44
9.12
2.55
10.52 2.69
11.46 2.77
12.63 2.89
5.77
2.17
6.98
2.28
8.19
2.39
9.40
2.50
10.85 2.63
11.81 2.71
13.02 2.82

Indoor air temp.:CDB


20C
21C
TC
PI
TC
PI
kW
kW
kW
kW
5.61
2.19
5.54
2.20
6.82
2.30
6.75
2.31
8.03
2.41
7.95
2.42
9.23
2.52
9.16
2.53
10.68 2.65 10.61 2.66
11.64 2.74 11.57 2.75
12.85 2.85 12.78 2.86
5.64
2.18
5.56
2.20
6.85
2.29
6.77
2.30
8.06
2.40
7.98
2.41
9.27
2.51
9.19
2.52
10.72 2.64 10.65 2.65
11.69 2.73 11.61 2.74
12.90 2.84 12.82 2.85
5.65
2.18
5.58
2.19
6.87
2.28
6.79
2.30
8.08
2.39
8.01
2.40
9.29
2.50
9.22
2.51
10.75 2.63 10.68 2.64
11.72 2.72 11.65 2.73
12.93 2.82 12.86 2.84
5.46
2.25
5.39
2.26
6.63
2.36
6.56
2.37
7.80
2.47
7.73
2.49
8.97
2.59
8.90
2.60
10.38 2.72 10.31 2.73
11.32 2.81 11.25 2.82
12.49 2.92 12.42 2.93
5.62
2.19
5.55
2.20
6.83
2.30
6.75
2.31
8.03
2.41
7.96
2.42
9.24
2.52
9.17
2.53
10.69 2.65 10.62 2.66
11.66 2.74 11.58 2.75
12.86 2.85 12.79 2.86
5.64
2.18
5.57
2.20
6.85
2.29
6.78
2.30
8.06
2.40
7.99
2.41
9.28
2.51
9.20
2.52
10.73 2.64 10.66 2.65
11.70 2.73 11.63 2.74
12.91 2.84 12.84 2.85
5.78
2.14
5.71
2.15
7.03
2.25
6.95
2.26
8.27
2.36
8.19
2.37
9.51
2.46
9.43
2.47
11.00 2.59 10.92 2.60
11.99 2.68 11.92 2.69
13.24 2.78 13.16 2.79
5.46
2.24
5.39
2.25
6.63
2.35
6.56
2.37
7.80
2.46
7.73
2.48
8.97
2.58
8.90
2.59
10.38 2.71 10.31 2.72
11.32 2.80 11.25 2.81
12.49 2.91 12.42 2.92
5.63
2.19
5.55
2.20
6.83
2.30
6.76
2.31
8.04
2.41
7.97
2.42
9.25
2.52
9.18
2.53
10.70 2.65 10.63 2.66
11.67 2.74 11.59 2.75
12.87 2.85 12.80 2.86

22C
TC
PI
kW
kW
5.47
2.22
6.67
2.32
7.88
2.43
9.09
2.54
10.53 2.67
11.50 2.76
12.70 2.87
5.49
2.21
6.70
2.32
7.91
2.42
9.12
2.53
10.57 2.66
11.54 2.75
12.75 2.86
5.50
2.20
6.72
2.31
7.93
2.42
9.14
2.52
10.60 2.65
11.57 2.74
12.79 2.85
5.31
2.27
6.49
2.39
7.66
2.50
8.83
2.61
10.24 2.74
11.17 2.83
12.35 2.95
5.47
2.22
6.68
2.32
7.89
2.43
9.09
2.54
10.54 2.67
11.51 2.76
12.72 2.87
5.49
2.21
6.70
2.32
7.92
2.42
9.13
2.53
10.58 2.66
11.55 2.75
12.76 2.86
5.63
2.17
6.87
2.27
8.12
2.38
9.36
2.49
10.85 2.61
11.84 2.70
13.08 2.81
5.31
2.27
6.49
2.38
7.66
2.49
8.83
2.60
10.24 2.73
11.17 2.82
12.35 2.94
5.48
2.22
6.69
2.32
7.89
2.43
9.10
2.54
10.55 2.67
11.52 2.76
12.73 2.87

24C
TC
PI
kW
kW
5.32
2.24
6.53
2.35
7.73
2.46
8.94
2.57
10.39 2.70
11.35 2.79
12.56 2.89
5.34
2.23
6.55
2.34
7.76
2.45
8.97
2.56
10.42 2.69
11.39 2.77
12.60 2.88
5.35
2.22
6.57
2.33
7.78
2.44
9.00
2.55
10.45 2.68
11.42 2.76
12.64 2.87
5.17
2.30
6.34
2.41
7.51
2.52
8.69
2.63
10.09 2.77
11.03 2.86
12.20 2.97
5.33
2.24
6.53
2.35
7.74
2.46
8.95
2.57
10.39 2.70
11.36 2.79
12.57 2.89
5.34
2.23
6.56
2.34
7.77
2.45
8.98
2.56
10.43 2.69
11.40 2.77
12.61 2.88
5.48
2.19
6.72
2.30
7.96
2.40
9.21
2.51
10.70 2.64
11.69 2.72
12.93 2.83
5.17
2.29
6.34
2.40
7.51
2.51
8.69
2.62
10.09 2.76
11.03 2.85
12.20 2.96
5.33
2.24
6.54
2.35
7.75
2.46
8.95
2.57
10.40 2.70
11.37 2.79
12.58 2.89

SUPER MULTI NX E-Series Heat Pump

EDAU12-722

Combination
(Capacity)
2.5+2.5+2.5+2.5

2.5+2.5+2.5+3.5

2.5+2.5+2.5+5.0

2.5+2.5+2.5+6.0

2.5+2.5+3.5+3.5

2.5+2.5+3.5+5.0

2.5+2.5+3.5+6.0

2.5+3.5+3.5+3.5

2.5+3.5+3.5+5.0

Capacity Tables

Outdoor
air temp.
CWB
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0

SUPER MULTI NX E-Series Heat Pump

16C
TC
PI
kW
kW
5.73
2.20
6.90
2.31
8.07
2.42
9.24
2.54
10.65 2.67
11.58 2.76
12.75 2.87
5.74
2.20
6.91
2.31
8.08
2.42
9.25
2.54
10.66 2.67
11.59 2.76
12.76 2.87
5.91
2.14
7.12
2.25
8.32
2.36
9.53
2.47
10.97 2.60
11.94 2.69
13.15 2.80
5.93
2.14
7.14
2.24
8.35
2.35
9.56
2.46
11.02 2.59
11.98 2.68
13.19 2.79
5.74
2.20
6.92
2.31
8.09
2.42
9.26
2.54
10.67 2.67
11.60 2.76
12.78 2.87
5.92
2.14
7.12
2.25
8.33
2.36
9.54
2.47
10.99 2.60
11.95 2.69
13.16 2.80
5.94
2.14
7.15
2.24
8.36
2.35
9.57
2.46
11.03 2.59
12.00 2.68
13.21 2.79
5.74
2.19
6.92
2.30
8.09
2.42
9.26
2.53
10.67 2.66
11.60 2.75
12.78 2.86
5.92
2.14
7.13
2.25
8.34
2.36
9.55
2.47
11.00 2.60
11.96 2.69
13.17 2.80

18C
TC
PI
kW
kW
5.59
2.23
6.76
2.34
7.93
2.45
9.10
2.56
10.50 2.70
11.44 2.79
12.61 2.90
5.60
2.23
6.77
2.34
7.94
2.45
9.11
2.56
10.51 2.70
11.45 2.79
12.62 2.90
5.76
2.17
6.97
2.28
8.17
2.39
9.38
2.50
10.83 2.63
11.79 2.71
13.00 2.82
5.78
2.16
6.99
2.27
8.20
2.38
9.42
2.49
10.87 2.62
11.84 2.70
13.05 2.81
5.60
2.23
6.77
2.34
7.94
2.45
9.12
2.56
10.52 2.70
11.46 2.79
12.63 2.90
5.77
2.17
6.97
2.28
8.18
2.39
9.39
2.50
10.84 2.63
11.80 2.71
13.01 2.82
5.79
2.16
7.00
2.27
8.21
2.38
9.42
2.49
10.88 2.62
11.85 2.70
13.06 2.81
5.60
2.22
6.77
2.33
7.94
2.44
9.12
2.55
10.52 2.69
11.46 2.77
12.63 2.89
5.77
2.17
6.98
2.28
8.19
2.39
9.40
2.50
10.85 2.63
11.81 2.71
13.02 2.82

Indoor air temp.:CDB


20C
21C
TC
PI
TC
PI
kW
kW
kW
kW
5.45
2.25
5.38
2.26
6.62
2.36
6.55
2.37
7.79
2.47
7.71
2.49
8.96
2.59
8.88
2.60
10.36 2.72 10.29 2.73
11.30 2.81 11.22 2.82
12.47 2.92 12.39 2.93
5.45
2.25
5.38
2.26
6.62
2.36
6.55
2.37
7.79
2.47
7.72
2.49
8.96
2.59
8.89
2.60
10.37 2.72 10.30 2.73
11.31 2.81 11.24 2.82
12.48 2.92 12.41 2.93
5.61
2.19
5.54
2.20
6.82
2.30
6.75
2.31
8.03
2.41
7.95
2.42
9.23
2.52
9.16
2.53
10.68 2.65 10.61 2.66
11.64 2.74 11.57 2.75
12.85 2.85 12.78 2.86
5.64
2.18
5.56
2.20
6.85
2.29
6.77
2.30
8.06
2.40
7.98
2.41
9.27
2.51
9.19
2.52
10.72 2.64 10.65 2.65
11.69 2.73 11.61 2.74
12.90 2.84 12.82 2.85
5.46
2.25
5.39
2.26
6.63
2.36
6.56
2.37
7.80
2.47
7.73
2.49
8.97
2.59
8.90
2.60
10.38 2.72 10.31 2.73
11.32 2.81 11.25 2.82
12.49 2.92 12.42 2.93
5.62
2.19
5.55
2.20
6.83
2.30
6.75
2.31
8.03
2.41
7.96
2.42
9.24
2.52
9.17
2.53
10.69 2.65 10.62 2.66
11.66 2.74 11.58 2.75
12.86 2.85 12.79 2.86
5.64
2.18
5.57
2.20
6.85
2.29
6.78
2.30
8.06
2.40
7.99
2.41
9.28
2.51
9.20
2.52
10.73 2.64 10.66 2.65
11.70 2.73 11.63 2.74
12.91 2.84 12.84 2.85
5.46
2.24
5.39
2.25
6.63
2.35
6.56
2.37
7.80
2.46
7.73
2.48
8.97
2.58
8.90
2.59
10.38 2.71 10.31 2.72
11.32 2.80 11.25 2.81
12.49 2.91 12.42 2.92
5.63
2.19
5.55
2.20
6.83
2.30
6.76
2.31
8.04
2.41
7.97
2.42
9.25
2.52
9.18
2.53
10.70 2.65 10.63 2.66
11.67 2.74 11.59 2.75
12.87 2.85 12.80 2.86

22C
TC
PI
kW
kW
5.30
2.27
6.47
2.39
7.64
2.50
8.81
2.61
10.22 2.74
11.15 2.83
12.32 2.95
5.31
2.27
6.48
2.39
7.65
2.50
8.82
2.61
10.23 2.74
11.16 2.83
12.33 2.95
5.47
2.22
6.67
2.32
7.88
2.43
9.09
2.54
10.53 2.67
11.50 2.76
12.70 2.87
5.49
2.21
6.70
2.32
7.91
2.42
9.12
2.53
10.57 2.66
11.54 2.75
12.75 2.86
5.31
2.27
6.49
2.39
7.66
2.50
8.83
2.61
10.24 2.74
11.17 2.83
12.35 2.95
5.47
2.22
6.68
2.32
7.89
2.43
9.09
2.54
10.54 2.67
11.51 2.76
12.72 2.87
5.49
2.21
6.70
2.32
7.92
2.42
9.13
2.53
10.58 2.66
11.55 2.75
12.76 2.86
5.31
2.27
6.49
2.38
7.66
2.49
8.83
2.60
10.24 2.73
11.17 2.82
12.35 2.94
5.48
2.22
6.69
2.32
7.89
2.43
9.10
2.54
10.55 2.67
11.52 2.76
12.73 2.87

24C
TC
PI
kW
kW
5.16
2.30
6.33
2.41
7.50
2.52
8.67
2.63
10.07 2.77
11.01 2.86
12.18 2.97
5.17
2.30
6.34
2.41
7.51
2.52
8.68
2.63
10.08 2.77
11.02 2.86
12.19 2.97
5.32
2.24
6.53
2.35
7.73
2.46
8.94
2.57
10.39 2.70
11.35 2.79
12.56 2.89
5.34
2.23
6.55
2.34
7.76
2.45
8.97
2.56
10.42 2.69
11.39 2.77
12.60 2.88
5.17
2.30
6.34
2.41
7.51
2.52
8.69
2.63
10.09 2.77
11.03 2.86
12.20 2.97
5.33
2.24
6.53
2.35
7.74
2.46
8.95
2.57
10.39 2.70
11.36 2.79
12.57 2.89
5.34
2.23
6.56
2.34
7.77
2.45
8.98
2.56
10.43 2.69
11.40 2.77
12.61 2.88
5.17
2.29
6.34
2.40
7.51
2.51
8.69
2.62
10.09 2.76
11.03 2.85
12.20 2.96
5.33
2.24
6.54
2.35
7.75
2.46
8.95
2.57
10.40 2.70
11.37 2.79
12.58 2.89

163

Capacity Tables

Combination
(Capacity)
3.5+3.5+3.5+3.5

EDAU12-722

Outdoor
air temp.
CWB
-15.0
-10.0
-5.0
0.0
6.0
10.0
15.0

Symbols

16C
TC
PI
kW
kW
5.75
2.19
6.92
2.30
8.10
2.42
9.27
2.53
10.68 2.66
11.62 2.75
12.79 2.86

18C
TC
PI
kW
kW
5.61
2.22
6.78
2.33
7.95
2.44
9.13
2.55
10.53 2.69
11.47 2.77
12.65 2.89

Indoor air temp.:CDB


20C
21C
TC
PI
TC
PI
kW
kW
kW
kW
5.46
2.24
5.39
2.25
6.64
2.35
6.56
2.37
7.81
2.46
7.74
2.48
8.98
2.58
8.91
2.59
10.39 2.71 10.32 2.72
11.33 2.80 11.26 2.81
12.50 2.91 12.43 2.92

22C
TC
PI
kW
kW
5.32
2.27
6.49
2.38
7.67
2.49
8.84
2.60
10.25 2.73
11.19 2.82
12.36 2.94

24C
TC
PI
kW
kW
5.18
2.29
6.35
2.40
7.52
2.51
8.70
2.62
10.10 2.76
11.04 2.85
12.21 2.96

NOTE:

TC

: Total capacity

(kW)

PI

: Power input

(kW)

Capacities are based on the following conditions.


Corresponding refrigerant piping length : 7.5m
Level difference : 0m
3D052669#1
3D052669#2
3D052669#3
3D052669#4
3D052669#5
3D052669#6
3D052669#7
3D052669#8
3D052669#9

164

SUPER MULTI NX E-Series Heat Pump

EDAU12-722

7.2

Capacity Tables

Capacity Correction Factor by the Length of Refrigerant Piping (Reference)


The cooling and the heating capacity of the unit has to be corrected in accordance with the length of
refrigerant piping. (The distance between the indoor unit and the outdoor unit)
< line: Cooling capacity>
<--- line: Heating capacity>

7.2.1

20 / 25 / 35 / 50 class
R-410A 20/25/35/50class

Capacity correction factor

0.9

0.8

10

15

20

25

Piping length (m)


(R5241)

7.2.2

60 / 71 class
R-410A 60/71class

Capacity correction factor

0.9

0.8

10

15

20

25

Piping length (m)


(R5489)

Note:

1. The graphs show the factor when additional refrigerant of the proper quantity is charged.
2. If it is for the multi-type room air-conditioner, the variation of the capacity will be smaller when only one
indoor unit is in operation.

SUPER MULTI NX E-Series Heat Pump

165

Operation Limit

EDAU12-722

8. Operation Limit
3MXS52EVMA, 3MXS68EVMA
Heating

(50/60Hz)

Cooling
50

15.5

46
40

5
Continuous operation

10

Pull-down period

20

Outdoor temp. (CWB)

30
Continuous operation

Outdoor temp. (CDB)

10

-5

0
-10
-5
-15
(-15CDB)
10

20

14

23

28 30

20
10
Indoor temp. (CDB)

Notes:
The graphs are based
on the following conditions.
Equivalent piping length 7.5m
Level difference
0m
Air flow rate
High

Indoor temp. (CWB)

30

3D054636

4MXS80EVMA
Heating

(50/60Hz)

Cooling
50
46

15.5

40
10

-5

Continuous operation

10

Outdoor temp.(CWB)

20

Pull-down period

Continuous operation

Outdoor temp.(CDB)

30

0
-10
-10
-15
(-15CDB)
10

14

20

23

Indoor temp.(CWB)

166

28 30
Notes:
The graphs are based
on the following conditions.
Equivalent piping length
Level difference
Air flow rate

20
10
Indoor temp.(CDB)
7.5m
0m
High

30

3D052043

SUPER MULTI NX E-Series Heat Pump

EDAU12-722

Fan Characteristics

9. Fan Characteristics
9.1

External Static Pressure

FDXS25CVMA

2
(Pa)
70

60

50

rn
a

External static pressure

(mmH2O)

40

U
st ppe
at r
ic lim
pr i
es t o
su f e
re xt
e

(mmH2O)
7

30

H
3
l
rna

xte
fe
it oure
m
i
r l ss
we re
Lotatic p
s

20

SL

10

(Pa)
6

(mmH2O)

8
9
Air flow rate (m3/min)

10

11

(mmH2O)

3D045760E

FDXS35CVMA

(mmH2O)
7

(Pa)

(mmH2O)

70

60

50

External static pressure

na

40

er
xt
fee
o
it ur
lim ss
er pre
p
c
Up tati
s
L

30

20
SL

4
H
3

nal

te
f ex
it o e
lim ssur
r
e re
Lowatic p
st

10

(Pa)
(mmH2O)

SUPER MULTI NX E-Series Heat Pump

8
9
10
Air flow rate (m3/min)

11

(mmH2O)

3D045761E

167

Fan Characteristics

EDAU12-722

FDXS50CVMA

(mmH2O)
7

(Pa)

60

50

External static pressure

(mmH2O)

70

5
l

a
rn

e
xt
fe
ti o ure
im s
r l res
pe ic p
p
U tat
s

40

4
H

30

L
2

20

SL

rnal

exte
it of
er lim ure
Low c press
stati

10

(Pa)
8

(mmH2O)

11
12
10
Air flow rate (m3/min)

13

14

(mmH2O)
3D045762D

FDXS60CVMA

(mmH2O)
7

(Pa)

60

50

External static pressure

(mmH2O)

70

5
l

na

r
xte
f ee
o
t r
mi su
r li es
pe ic pr
p
U tat
s

40

H
4

L
30

SL
2

20

10

rnal

te
of ex
r limitssure
e
w
o
e
r
L tic p
sta

(Pa)
(mmH2O)

9.5

10.5

11.5

12.5

13.5

14.5

Air flow rate (m3/min)

168

15.5

16.5

17.5

(mmH2O)
3D045763D

SUPER MULTI NX E-Series Heat Pump

EDAU12-722

Fan Characteristics

CDXS25EAVMA, CDXS35EAVMA

(mmH 2 O)
7

(Pa)
70

(mmH 2 O)
7

2
6

50

Up
sta p e r o
tic f li
pre mit
ssu e x
re tern
a

60

External static pressure

40

30

3
H

20

2
L

10
SL
(Pa)

(mmH 2 O)

10

11 (mmH 2 O)

Air flow rate(m 3 /min)

3D051853

SUPER MULTI NX E-Series Heat Pump

169

Sound Level

EDAU12-722

10. Sound Level


10.1 Measuring Location
Indoor Units
Duct Connected Type

Wall Mounted Type

2m

1m

DUCT

DUCT

0.8m

1.5m

1m

MICROPHONE

(R4124)
(R1759)

Floor / Ceiling Suspended Dual Type

Floor Standing Type

1m

1m

0.8m

1m

(R1002)

Ceiling Mounted Cassette Type

Outdoor Units

1m

(R1003)

Note:

170

1. Operation sound is measured in an anechoic chamber.


2. The data are based on the conditions shown in the table below.
Cooling

Heating

Piping Length

Indoor ; 27CDB/19CWB
Outdoor ; 35CDB

Indoor ; 20CDB
Outdoor ; 7CDB/6CWB

5m

SUPER MULTI NX E-Series Heat Pump

EDAU12-722

Sound Level

10.2 Octave Band Level


10.2.1 Indoor Units
FTXS20DVMA, FTXS25EVMA
COOLING

70

OVER ALL ( dB )
50/60Hz
SCALE 220-240/220-230V
(H)

NC-60

60

NC-50

50/60Hz
220-240/220-230V
(L)

37

25

( B.G.N IS ALREADY RECTIFIED )

50

OPERATING CONDITIONS
NC-40

POWER SOURCE

40

220-240/220-230V 50/60Hz

JIS STANDARD
STANDARD EXTERNAL STATIC PRESSURE
50/60Hz 220-240/220-230V(H)

NC-30

30

50/60Hz 220-240/220-230V(L)
Cooling

NC-20

20

APPROXIMATE
THRESHOLD HEARING
FOR CONTINUOUS
NOISE
63

125
250
500 1000 2000 4000
OCTAVE BAND CENTER FREQUENCY (Hz)

OCTAVE BAND SOUND PRESSURE LEVEL


dB(0dB=0.0002 bar)

OCTAVE BAND SOUND PRESSURE LEVEL


dB(0dB=0.0002 bar)

70

HEATING
OVER ALL ( dB )
50/60Hz
SCALE 220-240/220-230V
(H)

NC-60

60

NC-50

50/60Hz
220-240/220-230V
(L)

37

28

( B.G.N IS ALREADY RECTIFIED )

50

OPERATING CONDITIONS
NC-40

POWER SOURCE

40

220-240/220-230V 50/60Hz

JIS STANDARD
STANDARD EXTERNAL STATIC PRESSURE
50/60Hz 220-240/220-230V(H)

NC-30

30

50/60Hz 220-240/220-230V(L)
Heating

NC-20

20

APPROXIMATE
THRESHOLD HEARING
FOR CONTINUOUS
NOISE
63

8000

125
250
500 1000 2000 4000
OCTAVE BAND CENTER FREQUENCY (Hz)

3D048277B

8000

FTXS35EVMA
COOLING

70

OVER ALL ( dB )
50/60Hz
SCALE 220-240/220-230V
(H)

NC-60

60

NC-50

50/60Hz
220-240/220-230V
(L)

38

26

( B.G.N IS ALREADY RECTIFIED )

50

OPERATING CONDITIONS
NC-40

POWER SOURCE

40

220-240/220-230V 50/60Hz

JIS STANDARD
STANDARD EXTERNAL STATIC PRESSURE
50/60Hz 220-240/220-230V(H)

NC-30

30

50/60Hz 220-240/220-230V(L)
Cooling

NC-20

20

APPROXIMATE
THRESHOLD HEARING
FOR CONTINUOUS
NOISE
63

125
250
500 1000 2000 4000
OCTAVE BAND CENTER FREQUENCY (Hz)

OCTAVE BAND SOUND PRESSURE LEVEL


dB(0dB=0.0002 bar)

OCTAVE BAND SOUND PRESSURE LEVEL


dB(0dB=0.0002 bar)

70

HEATING
OVER ALL ( dB )
50/60Hz
SCALE 220-240/220-230V
(H)

NC-60

60

NC-50

50/60Hz
220-240/220-230V
(L)

38

29

( B.G.N IS ALREADY RECTIFIED )

50

OPERATING CONDITIONS
NC-40

POWER SOURCE

40

220-240/220-230V 50/60Hz

JIS STANDARD
STANDARD EXTERNAL STATIC PRESSURE
50/60Hz 220-240/220-230V(H)

NC-30

30

50/60Hz 220-240/220-230V(L)
Heating

NC-20

20

APPROXIMATE
THRESHOLD HEARING
FOR CONTINUOUS
NOISE
63

8000

125
250
500 1000 2000 4000
OCTAVE BAND CENTER FREQUENCY (Hz)

3D048278B

8000

FTXS50FVMA
COOLING

70

OVER ALL ( dB )
50/60Hz
50/60Hz
SCALE 220-240/220-230V 220-240/220-230V
(H)
(L)

NC-60
60

44

NC-50

35

( B.G.N IS ALREADY RECTIFIED )

50

OPERATING CONDITIONS
NC-40

POWER SOURCE 220-240/220-230V 50/60Hz

40

JIS STANDARD
50/60Hz 220-240/220-230V(H)

NC-30
30

50/60Hz 220-240/220-230V(L)
Cooling
NC-20

20

APPROXIMATE
THRESHOLD HEARING
FOR CONTINUOUS
NOISE
63

125
250
500 1000 2000 4000
OCTAVE BAND CENTER FREQUENCY (Hz)

OCTAVE BAND SOUND PRESSURE LEVEL


dB(0dB=0.0002 bar)

OCTAVE BAND SOUND PRESSURE LEVEL


dB(0dB=0.0002 bar)

70

HEATING
OVER ALL ( dB )
50/60Hz
50/60Hz
SCALE 220-240/220-230V 220-240/220-230V
(H)
(L)

NC-60
60

42

NC-50

33

( B.G.N IS ALREADY RECTIFIED )

50

OPERATING CONDITIONS
NC-40

POWER SOURCE 220-240/220-230V 50/60Hz

40

JIS STANDARD
50/60Hz 220-240/220-230V(H)

NC-30
30

50/60Hz 220-240/220-230V(L)
Heating
NC-20

20

APPROXIMATE
THRESHOLD HEARING
FOR CONTINUOUS
NOISE
63

8000

125
250
500 1000 2000 4000
OCTAVE BAND CENTER FREQUENCY (Hz)

3D054979A

8000

FTXS60FVMA
COOLING

70

OVER ALL ( dB )
50/60Hz
SCALE 220-240/220-230V
(H)

NC-60

60

45

NC-50

50/60Hz
220-240/220-230V
(L)
36

( B.G.N IS ALREADY RECTIFIED )

50

OPERATING CONDITIONS
NC-40

POWER SOURCE

40

220-240/220-230V 50/60Hz

JIS STANDARD
50/60Hz 220-240/220-230V(H)

NC-30

30

50/60Hz 220-240/220-230V(L)
Cooling
NC-20

20

APPROXIMATE
THRESHOLD HEARING
FOR CONTINUOUS
NOISE
63

125
250
500 1000 2000 4000
OCTAVE BAND CENTER FREQUENCY (Hz)

8000

SUPER MULTI NX E-Series Heat Pump

OCTAVE BAND SOUND PRESSURE LEVEL


dB(0dB=0.0002 bar)

OCTAVE BAND SOUND PRESSURE LEVEL


dB(0dB=0.0002 bar)

70

HEATING
OVER ALL ( dB )
50/60Hz
SCALE 220-240/220-230V
(H)

NC-60

60

35

44

NC-50

50/60Hz
220-240/220-230V
(L)

( B.G.N IS ALREADY RECTIFIED )

50

OPERATING CONDITIONS
NC-40

POWER SOURCE

40

220-240/220-230V 50/60Hz

JIS STANDARD
NC-30

50/60Hz 220-240/220-230V(H)

30

50/60Hz 220-240/220-230V(L)
Heating
NC-20

20

APPROXIMATE
THRESHOLD HEARING
FOR CONTINUOUS
NOISE
63

125
250
500 1000 2000 4000
OCTAVE BAND CENTER FREQUENCY (Hz)

8000

3D040300E

171

Sound Level

EDAU12-722

FTXS71FVMA
COOLING

70

OVER ALL ( dB )
50/60Hz
50/60Hz
SCALE 220-240/220-230V 220-240/220-230V
(L)
(H)

NC-60

60

NC-50

46

37

( B.G.N IS ALREADY RECTIFIED )

50

OPERATING CONDITIONS
NC-40

POWER SOURCE 220-240/220-230V 50/60Hz

40

JIS STANDARD
50/60Hz 220-240/220-230V(H)

NC-30

30

50/60Hz 220-240/220-230V(L)
Cooling
NC-20

20

APPROXIMATE
THRESHOLD HEARING
FOR CONTINUOUS
NOISE
63

125
250
500 1000 2000 4000
OCTAVE BAND CENTER FREQUENCY (Hz)

OCTAVE BAND SOUND PRESSURE LEVEL


dB(0dB=0.0002 bar)

OCTAVE BAND SOUND PRESSURE LEVEL


dB(0dB=0.0002 bar)

70

HEATING
OVER ALL ( dB )
50/60Hz
50/60Hz
SCALE 220-240/220-230V 220-240/220-230V
(L)
(H)

NC-60

60

NC-50

46

37

( B.G.N IS ALREADY RECTIFIED )

50

OPERATING CONDITIONS
NC-40

POWER SOURCE 220-240/220-230V 50/60Hz

40

JIS STANDARD
50/60Hz 220-240/220-230V(H)

NC-30

30

50/60Hz 220-240/220-230V(L)
Heating
NC-20

20

APPROXIMATE
THRESHOLD HEARING
FOR CONTINUOUS
NOISE
63

8000

125
250
500 1000 2000 4000
OCTAVE BAND CENTER FREQUENCY (Hz)

3D040301D

8000

FDXS25CVMA
COOLING
50Hz/230V
SCALE 60Hz/220V
(H)

NC-60

OCTAVE BAND SOUND PRESSURE LEVEL


dB(0dB=0.0002 bar)

70

OVER ALL ( dB )

60

NC-50

50Hz/230V
60Hz/220V
(L)

35

31

( B.G.N IS ALREADY RECTIFIED )

50

OPERATING CONDITIONS
NC-40

230V/50Hz, 220V/60Hz

POWER SOURCE

40

JIS STANDARD
STANDARD EXTERNAL STATIC PRESSURE
(H) 230V/50Hz, 220V/60Hz

NC-30

30

(L) 230V/50Hz, 220V/60Hz


Cooling

NC-20

20

APPROXIMATE
THRESHOLD HEARING
FOR CONTINUOUS
NOISE
63

125
250
500 1000 2000 4000
OCTAVE BAND CENTER FREQUENCY (Hz)

OCTAVE BAND SOUND PRESSURE LEVEL


dB(0dB=0.0002 bar)

70

HEATING
OVER ALL ( dB )
NC-60

60
NC-50

SCALE

50Hz/230V
60Hz/220V
(H)

50Hz/230V
60Hz/220V
(L)

35

31

( B.G.N IS ALREADY RECTIFIED )

50

OPERATING CONDITIONS
NC-40

230V/50Hz, 220V/60Hz

POWER SOURCE

40

JIS STANDARD
STANDARD EXTERNAL STATIC PRESSURE
(H) 230V/50Hz, 220V/60Hz

NC-30

30

(L) 230V/50Hz, 220V/60Hz


Heating

NC-20

20

APPROXIMATE
THRESHOLD HEARING
FOR CONTINUOUS
NOISE
63

8000

125
250
500 1000 2000 4000
OCTAVE BAND CENTER FREQUENCY (Hz)

3D046243E

8000

FDXS35CVMA
COOLING

SCALE

50Hz/230V
60Hz/220V
(H)

50Hz/230V
60Hz/220V
(L)

35

31

NC-60

OCTAVE BAND SOUND PRESSURE LEVEL


dB(0dB=0.0002 bar)

70

OVER ALL ( dB )

60
NC-50

( B.G.N IS ALREADY RECTIFIED )

50

OPERATING CONDITIONS
NC-40

POWER SOURCE

40

JIS STANDARD
STANDARD EXTERNAL STATIC PRESSURE
(H) 230V/50Hz, 220V/60Hz

NC-30

30

(L) 230V/50Hz, 220V/60Hz


Cooling

NC-20

20

230V/50Hz, 220V/60Hz

APPROXIMATE
THRESHOLD HEARING
FOR CONTINUOUS
NOISE
63

125
250
500 1000 2000 4000
OCTAVE BAND CENTER FREQUENCY (Hz)

OCTAVE BAND SOUND PRESSURE LEVEL


dB(0dB=0.0002 bar)

70

HEATING
OVER ALL ( dB )

SCALE

50Hz/230V
60Hz/220V
(H)

50Hz/230V
60Hz/220V
(L)

35

31

NC-60

60
NC-50

( B.G.N IS ALREADY RECTIFIED )

50

OPERATING CONDITIONS
NC-40

230V/50Hz, 220V/60Hz

POWER SOURCE

40

JIS STANDARD
STANDARD EXTERNAL STATIC PRESSURE
(H) 230V/50Hz, 220V/60Hz

NC-30

30

(L) 230V/50Hz, 220V/60Hz


Heating

NC-20

20

APPROXIMATE
THRESHOLD HEARING
FOR CONTINUOUS
NOISE
63

8000

125
250
500 1000 2000 4000
OCTAVE BAND CENTER FREQUENCY (Hz)

3D046244E

8000

FDXS50CVMA
COOLING

70

OVER ALL ( dB )

SCALE

50Hz/230V
60Hz/220V
(H)

50Hz/230V
60Hz/220V
(L)

37

33

NC-60

60
NC-50

( B.G.N IS ALREADY RECTIFIED )

50

OPERATING CONDITIONS
NC-40

POWER SOURCE

40

230V/50Hz, 220V/60Hz

JIS STANDARD
STANDARD EXTERNAL STATIC PRESSURE
(H) 230V/50Hz, 220V/60Hz

NC-30

30

(L) 230V/50Hz, 220V/60Hz


Cooling

NC-20

20

APPROXIMATE
THRESHOLD HEARING
FOR CONTINUOUS
NOISE
63

172

125
250
500 1000 2000 4000
OCTAVE BAND CENTER FREQUENCY (Hz)

8000

OCTAVE BAND SOUND PRESSURE LEVEL


dB(0dB=0.0002 bar)

OCTAVE BAND SOUND PRESSURE LEVEL


dB(0dB=0.0002 bar)

70

HEATING
OVER ALL ( dB )

SCALE

50Hz/230V
60Hz/220V
(H)

50Hz/230V
60Hz/220V
(L)

37

33

NC-60

60
NC-50

( B.G.N IS ALREADY RECTIFIED )

50

OPERATING CONDITIONS
NC-40

POWER SOURCE

40

230V/50Hz, 220V/60Hz

JIS STANDARD
STANDARD EXTERNAL STATIC PRESSURE
(H) 230V/50Hz, 220V/60Hz

NC-30

30

(L) 230V/50Hz, 220V/60Hz


Heating

NC-20

20

APPROXIMATE
THRESHOLD HEARING
FOR CONTINUOUS
NOISE
63

125
250
500 1000 2000 4000
OCTAVE BAND CENTER FREQUENCY (Hz)

8000

3D046245D

SUPER MULTI NX E-Series Heat Pump

EDAU12-722

Sound Level

FDXS60CVMA
COOLING

70

OVER ALL ( dB )

SCALE

50Hz/230V
60Hz/220V
(H)

50Hz/230V
60Hz/220V
(L)

38

34

NC-60

60
NC-50

( B.G.N IS ALREADY RECTIFIED )

50

OPERATING CONDITIONS
NC-40

POWER SOURCE

40

230V/50Hz, 220V/60Hz

JIS STANDARD
STANDARD EXTERNAL STATIC PRESSURE
(H) 230V/50Hz, 220V/60Hz

NC-30

30

(L) 230V/50Hz, 220V/60Hz


Cooling

NC-20

20

APPROXIMATE
THRESHOLD HEARING
FOR CONTINUOUS
NOISE
63

125
250
500 1000 2000 4000
OCTAVE BAND CENTER FREQUENCY (Hz)

OCTAVE BAND SOUND PRESSURE LEVEL


dB(0dB=0.0002 bar)

OCTAVE BAND SOUND PRESSURE LEVEL


dB(0dB=0.0002 bar)

70

HEATING
OVER ALL ( dB )

SCALE

50Hz/230V
60Hz/220V
(H)

50Hz/230V
60Hz/220V
(L)

38

34

NC-60

60
NC-50

( B.G.N IS ALREADY RECTIFIED )

50

OPERATING CONDITIONS
NC-40

230V/50Hz, 220V/60Hz

POWER SOURCE

40

JIS STANDARD
STANDARD EXTERNAL STATIC PRESSURE
(H) 230V/50Hz, 220V/60Hz

NC-30

30

(L) 230V/50Hz, 220V/60Hz


Heating

NC-20

20

APPROXIMATE
THRESHOLD HEARING
FOR CONTINUOUS
NOISE
63

8000

125
250
500 1000 2000 4000
OCTAVE BAND CENTER FREQUENCY (Hz)

3D046246D

8000

CDXS25EAVMA, CDXS35EAVMA
COOLING

70

OVER ALL ( dB )
220-240V/50Hz
SCALE 220-230V/60Hz
(H)

NC-60

60

NC-50

220-240V/50Hz
220-230V/60Hz
(L)

35

31

( B.G.N IS ALREADY RECTIFIED )

50

OPERATING CONDITIONS
NC-40

POWER SOURCE 220-240V/50Hz, 220-230V/60Hz

40

JIS STANDARD
STANDARD EXTERNAL STATIC PRESSURE
(H) 220-240V/50Hz, 220-230V/60Hz

NC-30

30

(L) 220-240V/50Hz, 220-230V/60Hz


Cooling

NC-20

20

APPROXIMATE
THRESHOLD HEARING
FOR CONTINUOUS
NOISE
63

125
250
500 1000 2000 4000
OCTAVE BAND CENTER FREQUENCY (Hz)

OCTAVE BAND SOUND PRESSURE LEVEL


dB(0dB=0.0002 bar)

OCTAVE BAND SOUND PRESSURE LEVEL


dB(0dB=0.0002 bar)

70

HEATING
OVER ALL ( dB )
220-240V/50Hz
SCALE 220-230V/60Hz
(H)

NC-60

60

NC-50

220-240V/50Hz
220-230V/60Hz
(L)

35

31

( B.G.N IS ALREADY RECTIFIED )

50

OPERATING CONDITIONS
NC-40

POWER SOURCE 220-240V/50Hz,220-230V/60Hz

NC-30

STANDARD EXTERNAL STATIC PRESSURE


(H) 220-240V/50Hz, 220-230V/60Hz

40

JIS STANDARD

30

(L) 220-240V/50Hz, 220-230V/60Hz


Heating

NC-20

20

APPROXIMATE
THRESHOLD HEARING
FOR CONTINUOUS
NOISE
63

8000

125
250
500 1000 2000 4000
OCTAVE BAND CENTER FREQUENCY (Hz)

3D051866

8000

FLXS25BVMA
COOLING

70

OVER ALL ( dB )

SCALE

50Hz
230V(H)
(H)

50Hz
230V(L)
(L)

37

31

NC-60

60
NC-50

( B.G.N IS ALREADY RECTIFIED )

50

OPERATING CONDITIONS
NC-40

POWER SOURCE

40

230V 50Hz

JIS STANDARD
STANDARD EXTERNAL STATIC PRESSURE
50Hz 230V(H)

NC-30

30

50Hz 230V(L)
Cooling

NC-20

20

APPROXIMATE
THRESHOLD HEARING
FOR CONTINUOUS
NOISE
63

125
250
500 1000 2000 4000
OCTAVE BAND CENTER FREQUENCY (Hz)

OCTAVE BAND SOUND PRESSURE LEVEL


dB(0dB=0.0002 bar)

OCTAVE BAND SOUND PRESSURE LEVEL


dB(0dB=0.0002 bar)

70

HEATING
OVER ALL ( dB )

SCALE

50Hz
230V(H)
(H)

50Hz
230V(L)
(L)

37

31

NC-60

60
NC-50

( B.G.N IS ALREADY RECTIFIED )

50

OPERATING CONDITIONS
NC-40

230V 50Hz

POWER SOURCE

40

JIS STANDARD
NC-30

STANDARD EXTERNAL STATIC PRESSURE


50Hz 230V(H)

NC-20

Heating

30

50Hz 230V(L)

20

APPROXIMATE
THRESHOLD HEARING
FOR CONTINUOUS
NOISE
63

8000

125
250
500 1000 2000 4000
OCTAVE BAND CENTER FREQUENCY (Hz)

3D035245C

8000

FLXS35BVMA
COOLING

70

OVER ALL ( dB )

SCALE

50Hz
230V(H)
(H)

50Hz
230V(L)
(L)

38

32

NC-60

60
NC-50

( B.G.N IS ALREADY RECTIFIED )

50

OPERATING CONDITIONS
NC-40

POWER SOURCE

40

230V 50Hz

JIS STANDARD
STANDARD EXTERNAL STATIC PRESSURE
50Hz 230V(H)

NC-30

30

50Hz 230V(L)
NC-20

20

Cooling

APPROXIMATE
THRESHOLD HEARING
FOR CONTINUOUS
NOISE
63

125
250
500 1000 2000 4000
OCTAVE BAND CENTER FREQUENCY (Hz)

8000

SUPER MULTI NX E-Series Heat Pump

OCTAVE BAND SOUND PRESSURE LEVEL


dB(0dB=0.0002 bar)

OCTAVE BAND SOUND PRESSURE LEVEL


dB(0dB=0.0002 bar)

70

HEATING
OVER ALL ( dB )

SCALE

50Hz
230V(H)
(H)

50Hz
230V(L)
(L)

39

33

NC-60

60
NC-50

( B.G.N IS ALREADY RECTIFIED )

50

OPERATING CONDITIONS
NC-40

POWER SOURCE

40

230V 50Hz

JIS STANDARD
STANDARD EXTERNAL STATIC PRESSURE
50Hz 230V(H)

NC-30

30

50Hz 230V(L)
Heating

NC-20

20

APPROXIMATE
THRESHOLD HEARING
FOR CONTINUOUS
NOISE
63

125
250
500 1000 2000 4000
OCTAVE BAND CENTER FREQUENCY (Hz)

8000

3D035246C

173

Sound Level

EDAU12-722

FLXS50BVMA
COOLING

70

OVER ALL ( dB )

SCALE

50Hz
230V(H)
(H)

50Hz
230V(L)
(L)

47

39

NC-60

60
NC-50

( B.G.N IS ALREADY RECTIFIED )

50

OPERATING CONDITIONS
NC-40

POWER SOURCE

40

JIS STANDARD
STANDARD EXTERNAL STATIC PRESSURE
50Hz 230V(H)

NC-30

30

50Hz 230V(L)
Cooling

NC-20

20

230V 50Hz

APPROXIMATE
THRESHOLD HEARING
FOR CONTINUOUS
NOISE
63

125
250
500 1000 2000 4000
OCTAVE BAND CENTER FREQUENCY (Hz)

OCTAVE BAND SOUND PRESSURE LEVEL


dB(0dB=0.0002 bar)

OCTAVE BAND SOUND PRESSURE LEVEL


dB(0dB=0.0002 bar)

70

HEATING
OVER ALL ( dB )

SCALE

50Hz
230V(H)
(H)

50Hz
230V(L)
(L)

46

35

NC-60

60
NC-50

( B.G.N IS ALREADY RECTIFIED )

50

OPERATING CONDITIONS
NC-40

230V 50Hz

POWER SOURCE

40

JIS STANDARD
NC-30

STANDARD EXTERNAL STATIC PRESSURE


50Hz 230V(H)

NC-20

Heating

30

50Hz 230V(L)

20

APPROXIMATE
THRESHOLD HEARING
FOR CONTINUOUS
NOISE
63

8000

125
250
500 1000 2000 4000
OCTAVE BAND CENTER FREQUENCY (Hz)

3D035247C

8000

FLXS60BVMA
COOLING

70

OVER ALL ( dB )

SCALE

50Hz
230V(H)
(H)

50Hz
230V(L)
(L)

48

41

NC-60

60
NC-50

( B.G.N IS ALREADY RECTIFIED )

50

OPERATING CONDITIONS
NC-40

POWER SOURCE

40

230V 50Hz

JIS STANDARD
STANDARD EXTERNAL STATIC PRESSURE

NC-30

50Hz 230V(H)

30

50Hz 230V(L)
NC-20

20

Cooling

APPROXIMATE
THRESHOLD HEARING
FOR CONTINUOUS
NOISE
63

125
250
500 1000 2000 4000
OCTAVE BAND CENTER FREQUENCY (Hz)

OCTAVE BAND SOUND PRESSURE LEVEL


dB(0dB=0.0002 bar)

OCTAVE BAND SOUND PRESSURE LEVEL


dB(0dB=0.0002 bar)

70

HEATING
OVER ALL ( dB )

SCALE

50Hz
230V(H)
(H)

50Hz
230V(L)
(L)

47

37

NC-60

60
NC-50

( B.G.N IS ALREADY RECTIFIED )

50

OPERATING CONDITIONS
NC-40

230V 50Hz

POWER SOURCE

40

JIS STANDARD
STANDARD EXTERNAL STATIC PRESSURE

NC-30

50Hz 230V(H)

30

50Hz 230V(L)
NC-20

20

APPROXIMATE
THRESHOLD HEARING
FOR CONTINUOUS
NOISE
63

8000

Heating

125
250
500 1000 2000 4000
OCTAVE BAND CENTER FREQUENCY (Hz)

3D035248C

8000

FVXS25FV1A
70

COOLING

70

OVER ALL ( dB )

HEATING
OVER ALL ( dB )
NC-50

60
NC-40

SCALE

50Hz
230V(H)

50Hz
230V(L)

38

26

( B.G.N IS ALREADY RECTIFIED )

50

OPERATING CONDITIONS
NC-30

220-240V 50Hz

POWER SOURCE

40

JIS STANDARD
STANDARD EXTERNAL STATIC PRESSURE
50Hz 220-240V(H)

NC-20
30

50Hz 220-240V(L)
Cooling
20

APPROXIMATE
THRESHOLD HEARING
FOR CONTINUOUS
NOISE
63

125
250
500 1000 2000 4000
OCTAVE BAND CENTER FREQUENCY (Hz)

OCTAVE BAND SOUND PRESSURE LEVEL


dB(0dB=0.0002 bar)

OCTAVE BAND SOUND PRESSURE LEVEL


dB(0dB=0.0002 bar)

NC-50
60

NC-40

SCALE

50Hz
230V(H)

50Hz
230V(L)

38

26

( B.G.N IS ALREADY RECTIFIED )

50

OPERATING CONDITIONS
NC-30

POWER SOURCE

40

220-240V 50Hz

JIS STANDARD
STANDARD EXTERNAL STATIC PRESSURE
50Hz 220-240V(H)

NC-20
30

50Hz 220-240V(L)
Heating
20

APPROXIMATE
THRESHOLD HEARING
FOR CONTINUOUS
NOISE
63

8000

125
250
500 1000 2000 4000
OCTAVE BAND CENTER FREQUENCY (Hz)

3D056240

8000

FVXS35FV1A
70

COOLING

70

OVER ALL ( dB )

HEATING
OVER ALL ( dB )
NC-50

60
NC-40

SCALE

50Hz
230V(H)

50Hz
230V(L)

39

27

( B.G.N IS ALREADY RECTIFIED )

50

OPERATING CONDITIONS
NC-30

POWER SOURCE

40

220-240V 50Hz

JIS STANDARD
STANDARD EXTERNAL STATIC PRESSURE
50Hz 220-240V(H)

NC-20
30

50Hz 220-240V(L)
Cooling
20

APPROXIMATE
THRESHOLD HEARING
FOR CONTINUOUS
NOISE
63

174

125
250
500 1000 2000 4000
OCTAVE BAND CENTER FREQUENCY (Hz)

8000

OCTAVE BAND SOUND PRESSURE LEVEL


dB(0dB=0.0002 bar)

OCTAVE BAND SOUND PRESSURE LEVEL


dB(0dB=0.0002 bar)

NC-50
60

NC-40

SCALE

50Hz
230V(H)

50Hz
230V(L)

39

27

( B.G.N IS ALREADY RECTIFIED )

50

OPERATING CONDITIONS
NC-30

220-240V 50Hz

POWER SOURCE

40

JIS STANDARD
STANDARD EXTERNAL STATIC PRESSURE
50Hz 220-240V(H)

NC-20
30

50Hz 220-240V(L)
Heating
20

APPROXIMATE
THRESHOLD HEARING
FOR CONTINUOUS
NOISE
63

125
250
500 1000 2000 4000
OCTAVE BAND CENTER FREQUENCY (Hz)

8000

3D056239

SUPER MULTI NX E-Series Heat Pump

EDAU12-722

Sound Level

FVXS50FV1A
COOLING

70

NC-60
60
NC-50

SCALE

50Hz
230V(H)

50Hz
230V(L)

44

36

( B.G.N IS ALREADY RECTIFIED )

50

OPERATING CONDITIONS
NC-40

220-240V 50Hz

POWER SOURCE

40

JIS STANDARD
STANDARD EXTERNAL STATIC PRESSURE
50Hz 220-240V(H)

NC-30
30

50Hz 220-240V(L)
Cooling

NC-20
APPROXIMATE
THRESHOLD HEARING
FOR CONTINUOUS
NOISE
63

250
500 1000 2000 4000
125
OCTAVE BAND CENTER FREQUENCY (Hz)

OCTAVE BAND SOUND PRESSURE LEVEL


dB(0dB=0.0002 bar)

SCALE
A
C

60

HI
29.5
36.1

LOW
24.5
32.3

(B.G.N IS ALREADY RECTIFIED)

NC-50
50

OPERATING CONDITIONS
POWER SOURCE

NC-40

230V 50Hz

JIS STANDARD

40

HI

COOLING

NC-30
30

LOW

RETURN AIR TEMPERATURE : 27C DB, 19C WB


OUTDOOR TEMPERATURE : 35C DB, 24C WB

RETURN AIR TEMPERATURE : 20C DB, 15C WB


HEATING
OUTDOOR TEMPERATURE : 7C DB, 6C WB
4 DIRECTION DISCHARGE

NC-20
APPROXIMATE
THRESHOLD HEARING
FOR CONTINUOUS
NOISE
125
250
500
1000 2000 4000
OCTAVE BAND CENTER FREQUENCY (Hz)

50Hz
230V(L)

45

36

OPERATING CONDITIONS
NC-40

220-240V 50Hz

POWER SOURCE

40

JIS STANDARD
STANDARD EXTERNAL STATIC PRESSURE
50Hz 220-240V(H)

NC-30
30

50Hz 220-240V(L)
Heating

NC-20
20

APPROXIMATE
THRESHOLD HEARING
FOR CONTINUOUS
NOISE
125
250
500 1000 2000 4000
OCTAVE BAND CENTER FREQUENCY (Hz)

3D056238

8000

OVER ALL(dB)

NC-60

SCALE
A
C

60

NC-50

HI
32.0
38.0

LOW
25.0
32.7

(B.G.N IS ALREADY RECTIFIED)

50

OPERATING CONDITIONS
POWER SOURCE

NC-40
40

HI

NC-30
30

LOW

230V 50Hz

JIS STANDARD
RETURN AIR TEMPERATURE : 27C DB, 19C WB
COOLING
OUTDOOR TEMPERATURE : 35C DB, 24C WB
RETURN AIR TEMPERATURE : 20C DB, 15C WB
HEATING
OUTDOOR TEMPERATURE : 7C DB, 6C WB
4 DIRECTION DISCHARGE

NC-20
20

APPROXIMATE
THRESHOLD HEARING
FOR CONTINUOUS
NOISE
63

125
250
500
1000 2000 4000
OCTAVE BAND CENTER FREQUENCY (Hz)

4D040177A

8000

FFQ60B8V1B

70

OCTAVE BAND SOUND PRESSURE LEVEL


dB(0dB=0.0002 bar)

50Hz
230V(H)

( B.G.N IS ALREADY RECTIFIED )

50

4D040176A

8000

FFQ50B8V1B

70

OVER ALL(dB)
SCALE
A
C

NC-60
60

HI
38.0
42.5

LOW
28.0
35.0

(B.G.N IS ALREADY RECTIFIED)

NC-50
50

OPERATING CONDITIONS

NC-40

POWER SOURCE

HI

40

NC-30

240V 50Hz

JIS STANDARD
RETURN AIR TEMPERATURE : 27C DB, 19C WB
COOLING
OUTDOOR TEMPERATURE : 35C DB, 24C WB

LOW
HEATING

30

RETURN AIR TEMPERATURE : 20C DB, 15C WB


OUTDOOR TEMPERATURE : 7C DB, 6C WB

4 DIRECTION DISCHARGE

NC-20
APPROXIMATE
THRESHOLD HEARING
FOR CONTINUOUS
NOISE
63

NC-50

SCALE

70

OVER ALL(dB)

NC-60

20

60

FFQ35B8V1B

70

63

OVER ALL ( dB )
NC-60

63

FFQ25B8V1B

20

HEATING

8000

OCTAVE BAND SOUND PRESSURE LEVEL


dB(0dB=0.0002 bar)

20

OCTAVE BAND SOUND PRESSURE LEVEL


dB(0dB=0.0002 bar)

OVER ALL ( dB )

125
250
500
1000 2000 4000
OCTAVE BAND CENTER FREQUENCY (Hz)

8000

SUPER MULTI NX E-Series Heat Pump

4D040182A

OCTAVE BAND SOUND PRESSURE LEVEL


dB(0dB=0.0002 bar)

OCTAVE BAND SOUND PRESSURE LEVEL


dB(0dB=0.0002 bar)

70

OVER ALL(dB)

NC-60

SCALE
A
C

60

NC-50

LOW
34.0
39.5

(B.G.N IS ALREADY RECTIFIED)

50

OPERATING CONDITIONS

NC-40

HI

POWER SOURCE

LOW

COOLING

RETURN AIR TEMPERATURE : 27C DB, 19C WB


OUTDOOR TEMPERATURE : 35C DB, 24C WB

HEATING

RETURN AIR TEMPERATURE : 20C DB, 15C WB


OUTDOOR TEMPERATURE : 7C DB, 6C WB

NC-30
30

240V 50Hz

JIS STANDARD

40

4 DIRECTION DISCHARGE

NC-20
20

HI
42.0
45.6

APPROXIMATE
THRESHOLD HEARING
FOR CONTINUOUS
NOISE
63

125
250
500
1000 2000 4000
OCTAVE BAND CENTER FREQUENCY (Hz)

8000

4D040183A

175

Sound Level

EDAU12-722

10.2.2 Outdoor Units


3MXS52EVMA
COOLING
NC-60

60

50Hz
60Hz

SCALE
A

NC-50

220-240V
220-230V
46

( B.G.N IS ALREADY RECTIFIED )

50

OPERATING CONDITIONS
NC-40

POWER SOURCE

40

220-240/220-230V 50/60Hz

JIS STANDARD(JISC9612)
Cooling

NC-30

30
NC-20

20

70

OVER ALL ( dB )

APPROXIMATE
THRESHOLD HEARING
FOR CONTINUOUS
NOISE
63

125
250
500 1000 2000 4000
OCTAVE BAND CENTER FREQUENCY (Hz)

OCTAVE BAND SOUND PRESSURE LEVEL


dB(0dB=0.0002 bar)

OCTAVE BAND SOUND PRESSURE LEVEL


dB(0dB=0.0002 bar)

70

HEATING
OVER ALL ( dB )
NC-60

60

50Hz
60Hz

SCALE
A

NC-50

220-240V
220-230V
47

( B.G.N IS ALREADY RECTIFIED )

50

OPERATING CONDITIONS
NC-40

POWER SOURCE

40

220-240/220-230V 50/60Hz

JIS STANDARD(JISC9612)
Heating

NC-30

30
NC-20

20

APPROXIMATE
THRESHOLD HEARING
FOR CONTINUOUS
NOISE
63

8000

125
250
500 1000 2000 4000
OCTAVE BAND CENTER FREQUENCY (Hz)

3D034806F

8000

3MXS68EVMA
COOLING
NC-60

50Hz
60Hz

SCALE

60

NC-50

220-240V
220-230V
48

( B.G.N IS ALREADY RECTIFIED )

50

OPERATING CONDITIONS
NC-40

POWER SOURCE

40

220-240/220-230V 50/60Hz

JIS STANDARD(JISC9612)
Cooling

NC-30

30
NC-20

20

70

OVER ALL ( dB )

APPROXIMATE
THRESHOLD HEARING
FOR CONTINUOUS
NOISE
63

125
250
500 1000 2000 4000
OCTAVE BAND CENTER FREQUENCY (Hz)

OCTAVE BAND SOUND PRESSURE LEVEL


dB(0dB=0.0002 bar)

OCTAVE BAND SOUND PRESSURE LEVEL


dB(0dB=0.0002 bar)

70

HEATING
OVER ALL ( dB )
NC-60

60

50Hz
60Hz

SCALE
A

NC-50

220-240V
220-230V
49

( B.G.N IS ALREADY RECTIFIED )

50

OPERATING CONDITIONS
NC-40

POWER SOURCE

40

220-240/220-230V 50/60Hz

JIS STANDARD(JISC9612)
Heating

NC-30

30
NC-20

20

APPROXIMATE
THRESHOLD HEARING
FOR CONTINUOUS
NOISE
63

8000

125
250
500 1000 2000 4000
OCTAVE BAND CENTER FREQUENCY (Hz)

3D034807H

8000

4MXS80EVMA
COOLING
NC-60

60
NC-50

SCALE

50Hz 220V-240V
60Hz 220V-230V

48

( B.G.N IS ALREADY RECTIFIED )

50

OPERATING CONDITIONS
NC-40

POWER SOURCE 220-240/220-230V 50/60Hz

40

JIS STANDARD (JIS9612)


Cooling

NC-30

30
NC-20

20

APPROXIMATE
THRESHOLD HEARING
FOR CONTINUOUS
NOISE
63

176

70

OVER ALL ( dB )

125
250
500 1000 2000 4000
OCTAVE BAND CENTER FREQUENCY (Hz)

8000

OCTAVE BAND SOUND PRESSURE LEVEL


dB(0dB=0.0002 bar)

OCTAVE BAND SOUND PRESSURE LEVEL


dB(0dB=0.0002 bar)

70

HEATING
OVER ALL ( dB )
NC-60

60
NC-50

SCALE

50Hz 220V-240V
60Hz 220V-230V

49

( B.G.N IS ALREADY RECTIFIED )

50

OPERATING CONDITIONS
NC-40

POWER SOURCE 220-240/220-230V 50/60Hz

40

JIS STANDARD (JIS9612)


Heating

NC-30

30
NC-20

20

APPROXIMATE
THRESHOLD HEARING
FOR CONTINUOUS
NOISE
63

125
250
500 1000 2000 4000
OCTAVE BAND CENTER FREQUENCY (Hz)

8000

3D052341

SUPER MULTI NX E-Series Heat Pump

EDAU12-722

Electric Characteristics

11. Electric Characteristics


Model
Outdoor

Units
H/P
C/O

Hz

3MXS52EVMA

H/P

50/60

3MXS68EVMA

H/P

50/60

4MXS80EVMA

H/P

50/60

SYMBOLS:
MCA : MIN. CIRCUIT AMPS (A)
MFA : MAX. FUSE AMPS (A)
MSC : MAX. CURRENT DURING THE
STARTING COMPRESSOR (A)
RLA
: RATED LOAD AMPS (A)
OFM : OUTDOOR FAN MOTOR
FLA
: FULL LOAD AMPS (A)
W
: FAN MOTOR RATED OUTPUT (W)

Power supply

Volts

Min.

Max.

220
230
240
220
230
240
220
230
240

198
207
216
198
207
216
198
207
216

242
253
264
242
253
264
242
253
264

MCA

MFA

17.5

20

18.5

20

18.5

20

Comp.
MSC

RLA

7.3
7.3
7.3
9.0
9.0
9.0
9.7
9.7
9.7

6.44
6.47
6.50
8.12
8.15
8.18
8.05
8.05
8.05

OFM
W

FLA

43

0.33

43

0.33

86

0.97

NOTE:
1. RLA is based on the following conditions.
Cooling
Indoor temp.: 27CDB/19CWB
Outdoor temp.: 35CDB.
2. Voltage range.
Units are suitable for use on electrical systems where voltage
supplied to unit terminal is not below or above listed range limits.
3. Maximum allowable voltage variation between phases is 2%.
4. Select wire size based on the value of MCA.
5. MCA represents maximum input current.
MFA represents capacity which may accept MCA.
6. Instead of fuse, use circuit breaker.
7. MFA is used to select the circuit breaker and the ground fault
circuit interrupter (earth leakage circuit breaker).
8. Be sure to install an earth leak detector. (One that can handle
higher harmonics.)
(This unit uses an inverter, which means that it must be used an
earth leak detector capable handling high harmonics in order to
prevent malfunctioning of the earth leak detector itself.)
3D054873
3D052367

SUPER MULTI NX E-Series Heat Pump

177

Electric Characteristics

178

EDAU12-722

SUPER MULTI NX E-Series Heat Pump

EDAU12-722

Part 3
Installation Manual
1. Indoor Units.........................................................................................180
1.1
1.2
1.3
1.4
1.5
1.6
1.7
1.8
1.9

Safety Precautions ...............................................................................180


Wall Mounted Type FTXS 20 D............................................................181
Wall Mounted Type FTXS 25/35 E.......................................................189
Wall Mounted Type FTXS 50/60/70 F ..................................................196
Duct Connected Type FDXS 25/35/50/60 C ........................................203
Duct Connected Type CDXS 25/35 E ..................................................211
Floor / Ceiling Suspended Dual Type FLXS 25/35/50/60 B .................219
Floor Standing Type FVXS 25/35/50 F ................................................227
Ceiling Mounted Cassette Type FFQ 25/35/50/60 B............................238

2. Outdoor Units ......................................................................................260


2.1
2.2
2.3
2.4

Installation Manual

Safety Precautions ...............................................................................260


3MXS52EVMA .....................................................................................261
3MXS68EVMA .....................................................................................275
4MXS80EVMA .....................................................................................289

179

Indoor Units

EDAU12-722

1. Indoor Units
1.1

Safety Precautions

Safety Precautions
Read these Safety Precautions carefully to ensure correct installation.
This manual classifies the precautions into WARNING and CAUTION.
Be sure to follow all the precautions below: they are all important for ensuring safety.
WARNING

Failure to follow any of WARNING is likely to result in such grave consequences as death or serious injury.

CAUTION

Failure to follow any of CAUTION may result in grave consequences in some cases.

The following safety symbols are used throughout this manual:


Be sure to observe this instruction.

Be sure to establish an earth connection.

Never attempt.

After completing installation, test the unit to check for installation errors. Give the user adequate instructions
concerning the use and cleaning of the unit according to the Operation Manual.

WARNING
Installation should be left to the dealer or another professional. Improper installation may cause water leakage, electrical shock, or fire.
Install the air conditioner according to the instructions given in this manual. Incomplete installation may cause water leakage, electrical shock, or fire.
Be sure to use the supplied or specified installation parts. Use of other parts may cause the unit to come to lose, water leakage, electrical shock, or fire.
Install the air conditioner on a solid base that can support the weight of the unit.
An inadequate base or incomplete installation may cause injury in the event the unit falls off the base.

Electrical work should be carried out in accordance with the installation manual and the national electrical wiring
rules or code of practice.

Insufficient capacity or incomplete electrical work may cause electrical shock or fire.

Be sure to use a dedicated power circuit. Never use a power supply shared by another appliance.
For wiring, use a cable length enough to cover the entire distance with no connection.
Do not use an extension cord. Do not put other loads on the power supply, use a dedicated power circuit.
(Failure to do so may cause abnormal heat, electric shock or fire.)

Use the specified types of wires for electrical connections between the indoor and outdoor units.
Firmly clamp the interconnecting wires so their terminals receive no external stresses. Incomplete connections or clamping may cause terminal overheating or fire.

After connecting interconnecting and supply wiring be sure to shape the cables so that they do not put undue force on the
electrical covers or panels.

Install covers over the wires. Incomplete cover installation may cause terminal overheating, electrical shock, or fire.

When installing or relocating the system, be sure to keep the refrigerant circuit free from substances other than the specified
refrigerant (R410A), such as air.

(Any presence of air or other foreign substance in the refrigerant circuit causes an abnormal pressure rise or rupture, resulting in injury.)

The installation height from the floor must be over 1.8m.


If any refrigerant has leaked out during the installation work, ventilate the room.
(The refrigerant produces a toxic gas if exposed to flames.)

After all installation is complete, check to make sure that no refrigerant is leaking out.
(The refrigerant produces a toxic gas if exposed to flames.)

During pump-down, stop the compressor before removing the refrigerant piping. If the compressor is still running and the shut-off valve is open during
pump-down, air will be sucked in when the refrigerant piping is removed, causing abnormal pressure in the freezer cycle which will lead to breakage and even injury.

During installation, attach the refrigerant piping securely before running the compressor. If the compressor is not attached and the shut-off valve
is open during pump-down, air will be sucked in when the compressor is run, causing abnormal pressure in the freezer cycle which will lead to breakage and even injury.

Be sure to establish an earth. Do not earth the unit to a utility pipe, arrester, or telephone earth.
Incomplete earth may cause electrical shock, or fire.

A high surge current from lightning or other sources may cause damage to the air conditioner.

Be sure to install an earth leakage breaker. Failure to install an earth leakage breaker may result in electric shocks, or fire.

CAUTION
Do not install the air conditioner in a place where there is danger of exposure to inflammable gas leakage.
If the gas leaks and builds up around the unit, it may catch fire.

Establish drain piping according to the instructions of this manual. Inadequate piping may cause flooding.
Tighten the flare nut according to the specified method such as with a torque wrench.
If the flare nut is tightened too hard, the flare nut may crack after a long time and cause refrigerant leakage.

180

Installation Manual

EDAU12-722

1.2

Indoor Units

Wall Mounted Type FTXS 20 D

Accessories
Indoor unit fixing screws
M4 12L

A Mounting plate

D Wireless remote controller

Mounting platefixing screws


B
M4 25L

E Remote controller holder

J Insulation tape

K Operation manual

L Installation manual

C Titanium Apatite

Photocatalytic
Air-Purifying Filter

Fixing screws for remote


controller holder M3 20L

G AAA dry-cell batteries

Choosing an Installation Site


Before choosing the installation site, obtain user approval.

1.

Indoor unit.

1)
2)
3)
4)
5)
6)
7)

The indoor unit should be sited in a place where:


the restrictions on installation specified in the indoor unit installation drawings are met,
both air intake and exhaust have clear paths met,
the unit is not in the path of direct sunlight,
the unit is away from the source of heat or steam,
there is no source of machine oil vapour (this may shorten indoor unit life),
cool (warm) air is circulated throughout the room,
the unit is away from electronic ignition type fluorescent lamps (inverter or rapid start type) as they may shorten the
remote control range,
8) the unit is at least 1 metre away from any television or radio set (unit may cause interference with the picture or sound).
9) install at the recommended height (1.8m).

2.

Wireless remote controller.


1) Turn on all the fluorescent lamps in the room, if any, and find the site where remote control signals are properly
received by the indoor unit (within 7 metres).

Installation Tips
<When there is no work space because the unit is close to ceiling>

1. Removing and installing front panel.

Removal method

Caution

Hook fingers on the panel protrusions on the left and right of the main body,
and open until the panel stops. Slide the front panel sideways to disengage
the rotating shaft. Then pull the front
panel toward you to remove it.

1) Push up.

Be sure to wear protection gloves.

Place both hands under the center of the front


grille, and while pushing up, pull it toward you.

2) Pull toward you.

Installation method
1) Install the front grille and firmly engage the upper hooks (3 locations).
2) Install 2screws of the front grille.
3) Install the air filter and then mount the front panel.

Installation method
Push the
rotating shaft
of the front
panel into the
groove.

3. How to set the different


addresses.

2. Removing and installing front grille.


Removal method
1) Remove front panel to remove the air filter.
2) Remove the front grille.
mark of the front grille,
3) In front of the
there are 3 upper hooks. Lightly pull the
front grille toward you with one hand, and
push down on the hooks with the fingers of
your other hand.

mark area
(3 locations)

Upper hook

Lightly pull the front


grille toward you with
one hand, and push
down on the hooks with
the fingers of your other
hand. (3 locations)

Push
down.

Upper hook

Upper hook

ADDRESS

When two indoor units are


installed in one room, the
two wireless remote
controllers can be set for
different addresses.
1) In the same way as when
connecting to an HA
system, remove the metal
plate electrical wiring
cover.
2) Cut the address jumper
(JA) on the pindted circuit
board.
3) Cut the address jumper
(J4) in the remote control.

JA

Align the tabs of the front panel with the


grooves, and push all the way in. Then close
slowly. Push the center of the lower surface
of the panel firmly to engage the tabs.

JA ADDRESS
EXIST
CUT

1
2

J4

J4 ADDRESS
EXIST
CUT

Installation Manual

1
2

181

Indoor Units

EDAU12-722

Indoor Unit Installation Drawings


How to attach the indoor unit.
Hook the claws of the bottom frame
to the mounting plate.
If the claws are difficult to hook,
remove the front grille.
How to remove the indoor unit.
Push up the marked area (at the
lower part of the front grille) to
release the claws. If it is difficult to Front grille
release, remove the front grille.

A Mounting plate

A Mounting
plate

Clip

Bottom frame

Mark (rear side)

The mounting plate


should be installed on a
wall which can support the
weight of the indoor unit.
B Mounting platefixing
screws M4 25L (6)

Caulk
pipe hole
gap
with putty.

30 mm or more from ceiling

Cut thermal insulation


pipe to an appropriate
length and wrap it with
tape, making sure that no
gap is left in the insulation
pipes cut line.

Front panel

50 mm or more from walls


(on both sides)

Wrap the insulation pipe with


the finishing tape from bottom
to top.
Intelligent-eye sensor

Air filters

C Titanium Apatite Photocatalytic


Air-Purifying Filter (2)
Titanium Apatite
Photocatalytic
Air-Purifying Filter

Service lid
Opening service lid
Service lid is opening/closing type.
Opening method
1) Remove the service lid screws.
2) Pull out the service lid diagonally
down in the direction of the arrow.
3) Pull down.

Air filter

Filter frame

Tab

D Wireless
remote controller

F Fixing screws for


remote controller
holder M3 20L (2)

Before screwing the remote


controller holder to the wall,
make sure that control
signals are properly
received by indoor unit.
E
Remote
controller holder

Intelligent-eye Sensor
Caution
1) Do not hit or violently push the intelligent-eye sensor. This can lead to damage and malfunction.
2) Do not place large objects near the sensor. Also keep heating units or humidifiers outside the
sensors detection area.

182

Installation Manual

EDAU12-722

Indoor Units

Indoor Unit Installation


1.

Installing the mounting plate.


The mounting plate should be installed on a wall which can support the weight of the indoor unit.
1) Temporarily secure the mounting plate to the wall, make sure that the panel is completely level, and mark
the boring points on the wall.
2) Secure the mounting plate to the wall with screws.
Recommended mounting-plate retention spots and dimensions
450

Recommended
mounting - plate
retention spots
(6 spots in all)

400

(Bolt size : M10)

135

110
65
60

65
130
220

60

44.5

Use tape
measure
as shown.
Position the
end of a tape
measure at .

131.5
44.5 87

283

47.5

46.5

(Bolt size : M10)

50.5

141.5

b Place a leveler
on raised tab.

80

100

110

50
800

Drain hose
position

Throughthe-wall
hole 65mm

Liquid pipe end Keep here the piece cut out


from the unit for piping
Gas pipe end

* The removed pipe port cover can be


kept in the mounting plate pocket.

Removed pipe
port cover

A Mounting plate

2.

Boring a wall hole and installing wall embedded pipe.


For walls containing metal frame or metal board, be sure to use a wall
embedded pipe and wall cover in the feed-through hole to prevent
possible heat, electrical shock, or fire.
Be sure to caulk the gaps around the pipes with caulking material to
prevent water leakage.
1) Bore a feed-through hole of 65 mm in the wall so it has a down slope
toward the outside.
2) Insert a wall pipe into the hole.
3) Insert a wall cover into wall pipe.
4) After completing refrigerant piping, wiring, and drain piping, caulk pipe
hole gap with putty.

Installation Manual

Inside
Wall embedded pipe
(field supply)

Outside
Caulking

65

Wall hole cover


(field supply)
Wall embedded pipe
(field supply)

183

Indoor Units

EDAU12-722

3.

Installing indoor unit.


3-1. Right-side, right-back, or right-bottom piping.
1) Attach the drain hose to the
underside of the refrigerant pipes
with an adhesive vinyl tape.
2) Wrap the refrigerant pipes and
Remove pipe port cover
drain hose together with an
here for right-side piping. Right-bottom
piping
insulation tape.
Remove pipe port cover
here for right-bottom piping.

3) Pass the drain hose and


refrigerant pipes through the wall
hole, then set the indoor unit on
the mounting plate hooks by
using the markings at the top of
the indoor unit as a guide.

Right-back piping
Bind coolant pipe
and drain hose
together with
insulating tape.

A Mounting plate

4) Open the front panel, then


Hang indoor units hook here.
open the service lid. (Refer to
Installation tips)
5) Pass the interconnecting
A Mounting plate
wires from the outdoor unit
When stripping the
ends of interconnecting
in advance, bind
Interconnecting
through the feed-through wall wires
right ends of wires with
wires
insulating tape.
hole and then through the
Wire guide
back of the indoor unit. Pull
them through the front side.
Bend the ends of tie wires upward for easier work in advance.
(If the interconnecting wire ends are to be stripped first, bundle
wire ends with adhesive tape.)
6) Press the bottom frame of the indoor unit with both hands to
set it on the mounting plate hooks. Make sure that the wires do
not catch on the edge of the indoor unit.

3-2. Left-side, left-back, or left bottom piping.


1) Attach the drain hose to the
underside of the refrigerant
pipes with adhesive vinyl
tape.

Remove pipe
port cover
here for leftside piping.

Remove pipe port cover here for left-bottom piping.

Left-side
piping
Left-back
piping

Left-bottom piping

2) Be sure to connect the drain


hose to the drain port in place
of a drain plug.

184

How to set drain plug


No g

ap

Do not apply lubricating


oil (refrigerant machine
oil) when inserting.
Application of causes
deterioration and drain
leakage of the plug.
Insert a hexagon wrench (4 mm)

Installation Manual

EDAU12-722

Indoor Units

3) Shape the refrigerant pipe along the pipe path marking on the
mounting plate.
4) Pass drain hose and refrigerant pipes through the wall hole,
then set the indoor unit on mounting plate hooks, using the
markings at the top of indoor unit as a guide.

Drain
hose

A Mounting plate

Caulk this hole


with putty or
caulking material.

Bind with plastic


tape.

Wrap insulating tape around the bent portion


of refrigerant pipe.
Overlap at least half the width of the tape
with each turn.

5) Pull in the interconnecting wires.


6) Connect the inter-unit piping.
7) Wrap the refrigerant pipes and drain hose together with insulation
tape as right figure, in case of setting the drain hose through the back
of the indoor unit.
8) While exercising care so that the
A
Mounting
Drain hose
plate
interconnecting wires do not catch
Refrigerant
indoor unit, press the bottom edge of
pipes
indoor unit with both hands until it is
firmly caught by the mounting plate
Bottom frame
hooks. Secure indoor unit to the
H M4 12L (2 point)
mounting plate with the screws (M4 12L).
3-3. Wall embedded piping.
Follow the instructions given under
Insert drain hose
to this depth so
it wont be pulled
out of drain pipe.

Left-side, left-back, or left bottom piping


1) Insert the drain hose to this
depth so it wont be pulled out
of the drain pipe.

4.

Inner wall

50 mm
or more

Outer wall

Drain hose
Vinyl chloride
drain pipe
(VP-30)

Wiring.
With a Multi indoor unit , install as described in the installation
manual supplied with the Multi outdoor unit.
1) Strip wire ends (15 mm).
Terminal block
Electrical component box
2) Match wire colours with
Shape wires so
terminal numbers on indoor
that the service
lid will fit securely.
and outdoor units terminal
blocks and firmly screw wires
Firmly secure wire retainer
so that wires sustain no
to the corresponding terminals.
Use the
external stress.
specified
3) Connect the earth wires to the
Wire retainer
wire type.
corresponding terminals.
4) Pull wires to make sure that they are securely latched up, then retain wires with wire retainer.
5) In case of connecting to an adapter system. Run the remote control cable
and attach the S21. (Refer to 5. When connecting to an HA system.)
Firmly fix the wires with
6) Shape the wires so
the terminal screws.
Outdoor unit
that the service lid
When wire length exceeds
fits securely, then
10 m, use 2.0-mm wires.
close service lid.
1 23

Indoor
unit

LN

1
2
3

Safety
breaker
15A
Firmly fix the wires with
the terminal screws.

H05VV

Earth leakage
circuit breaker

Power
supply
50Hz 220V - 240V
60Hz 220V - 230V

Earth

Warning
1) Do not use tapped wires, stand wires, extensioncords, or starbust
connections, as they may cause overtheating, electrical shock,or fire.
2) Do not use locally purchased electrical parts inside the product. (Do not branch the power
for the drain pump, etc., from the terminal block.) Doing so may cause electric shock or fire.

Installation Manual

185

Indoor Units

EDAU12-722

5.

When connecting to an HA system.


1)
2)
3)
4)

Remove the front grille. (2 screws)


Remove the electrical wiring box. (1 screw)
Remove the metal plate electrical wiring cover. (3 tabs)
Attach the connection cord to the S21 connector and pull the
harness out through the notched part in the figure.
5) Replace the electrical wiring cover as it was, and pull the harness
around, as shown in the figure.
Tab

Notched part

Push
Slide

HA cord

HA connector
(S21)

Slide
3) Remove the metal
plate electrical
wiring cover.

6.

Screw
Pull
Tab

4) Attach the connection cord to


the S21 connector and pull the
harness out through the
notched part in the figure.

5) Replace the electrical


wiring cover as it was,
and pull the harness
around, as shown
in the figure.

Drain piping.
The drain hose should
be inclined downward.

1) Connect the drain hose, as described


right.

No trap is permitted.
Do not put the end
of the hose in water.

3) When drain hose requires extension,


obtain an extension hose commercially
available.
Be sure to thermally insulate the indoor
section of the extension hose.

Indoor unit
drain hose

18

2) Remove the air filters and pour some


water into the drain pan to check the water
flows smoothly.

Extension drain hose

Heat insulation tube


(Field supply)

18

4) When connecting a rigid polyvinyl chloride pipe (nominal diameter


13 mm) directly to the drain hose attached to the indoor unit as with
embedded piping work, use any commercially available drain
socket (nominal diameter 13 mm) as a joint.

Drain hose supplied with


the indoor unit

186

Commercially available drain


socket
(nominal diameter 13 mm)

Commercially available rigid


polyvinyl chloride pipe
(nominal diameter 13 mm)

Installation Manual

EDAU12-722

Indoor Units

Refrigerant Piping Work


With a Multi indoor unit

1.

, install as described in the installation manual supplied with the Multi outdoor unit.

Flaring the pipe end.


1) Cut the pipe end with a pipe cutter.
2) Remove burrs with the cut surface facing downward
so that the chips do not enter the pipe.
3) Put the flare nut on the pipe.
4) Flare the pipe.
5) Check that the flaring is properly made.

(Cut exactly at
right angles.)

Remove burrs

Flaring
Set exactly at the position shown below.
A

Die

Flare tool for R410A

Conventional flare tool

Clutch-type

Clutch-type (Rigid-type) Wing-nut type (Imperial-type)

0 ~ 0.5 mm

1.0 ~ 1.5 mm

1.5 ~ 2.0 mm

Check
Flares inner
surface must
be flaw-free.

The pipe end must


be evenly flared in
a perfect circle.
Make sure that the
flare nut is fitted.

Warning
1) Do not use mineral oil on flared part.
2) Prevent mineral oil from getting into the system as this would reduce the lifetime of the units.
3) Never use piping which has been used for previous installations. Only use parts which are delivered with the unit.
4) Do never install a drier to this R410A unit in order to guarantee its lifetime.
5) The drying material may dissolve and damage the system.
6) Incomplete flaring may cause refrigerant gas leakage.

2.

Refrigerant piping.
1) Align the centres of both flares and tighten the flare nuts 3 or 4 turns
by hand. Then tighten them fully with the torque wrenches.
Use torque wrenches when tightening the flare nuts to prevent
damage to the flare nuts and escaping gas.

Flare nut tightening torque


Gas side
Liquid side
3/8 inch
1/4 inch
32.7-39.9N m
14.2-17.2N m
(330-407kgf cm)
(144-175kgf cm)

Torque wrench

Coat here with refrigeration machine oil

Spanner

Piping union
Flare nut

2) To prevent gas leakage, apply refrigeration machine oil on both inner and outer surfaces of the flare. (Use
refrigeration oil for R410A)
2-1. Caution on piping handling.
Wall
Be sure to
1) Protect the open end of the pipe against dust and moisture.
place a cap.
2) All pipe bends should be as gentle as possible. Use a pipe
Rain
If no flare cap is
available, cover
bender for bending.
the flare mouth
with tape to keep
(Bending radius should be 30 to 40 mm or larger.)
dirt or water out.

2-2. Selection of copper and heat insulation materials.


When using commercial copper pipes and fittings, observe the following:
1) Insulation material: Polyethylene foam
Heat transfer rate: 0.041 to 0.052 W/mK (0.035 to 0.045 kcal/(mh C))
Refrigerant gas pipes surface temperature reaches 110C max.
Choose heat insulation materials that will withstand this
temperature.
2) Be sure to insulate both the gas and liquid piping and to provide
insulation dimensions as below.
Gas side

Liquid side

20/25/35 class
O.D. 9.5mm

O.D. 6.4mm
Thickness 0.8mm

Liquid pipe

Gas pipe
insulation

Gas pipe thermal insulation


20/25/35 class

Thickness 0.8mm

Inter-unit wiring
Gas pipe

Liquid pipe
insulation
Finishing tape

Drain hose

Liquid pipe
thermal insulation

I.D. 12-15mm

I.D. 8-10mm

Thickness 10mm Min.

3) Use separate thermal insulation pipes for gas and liquid refrigerant pipes.

Installation Manual

187

Indoor Units

EDAU12-722

Trial Operation and Testing


1.

Trial operation and testing.


1-1 Measure the supply voltage and make sure that it falls in the specified range.
1-2 Trial operation should be carried out in either cooling or heating mode.
For Heat pump

In cooling mode, select the lowest programmable temperature; in heating mode, select the highest
programmable temperature.
1) Trial operation may be disabled in either mode depending on the room temperature.
Use the remote control for trial operation as described below.
2) After trial operation is complete, set the temperature to a normal level (26C to 28C in cooling mode, 20C
to 24C in heating mode).
3) For protection, the system disables restart operation for 3 minutes after it is turned off.
For Cooling only

Select the lowest programmable temperature.


1) Trial operation in cooling mode may be disabled depending on the room temperature.
Use the remote control for trial operation as described below.
2) After trial operation is complete, set the temperature to a normal level (26C to 28C).
3) For protection, the system disables restart operation for 3 minutes after it is turned off.

1-3 Carry out the test operation in accordance with the operation manual to ensure that all functions and
parts, such as louver movement, are working properly.
The air conditioner requires a small amount of power in its standby mode. If the system is not to be used for
some time after installation, shut off the circuit breaker to eliminate unnecessary power consumption.

If the circuit breaker trips to shut off the power to the air conditioner, the system will restore the original
operation mode when the circuit breaker is opened again.

Trial operation from remote controller.


1) Press ON/OFF button to turn on the system.
2) Simultaneously press centre of TEMP button and MODE button.
3) Press MODE button twice.
( will appear on the display to indicate that Trial Operation mode is selected.)
4) Trial run mode terminates in approx. 30 minutes and switches into normal mode. To quit a trial
operation, press ON/OFF button.

2.

Test items.
Test items

Symptom
(diagnostic display on RC)

Indoor and outdoor units are installed properly on


solid bases.

Fall, vibration, noise

No refrigerant gas leaks.

Incomplete cooling/heating function

Refrigerant gas and liquid pipes and indoor drain


hose extension are thermally insulated.

Water leakage

Draining line is properly installed.

Water leakage

System is properly earthed.

Electrical leakage

The specified wires are used for interconnecting


wire connections.

Inoperative or burn damage

Indoor or outdoor units air intake or exhaust has


clear path of air. Shut-off valves are opened.

Incomplete cooling/heating function

Indoor unit properly receives remote controller


commands.

Inoperative

Check

3P142640-1H

188

Installation Manual

EDAU12-722

1.3

Indoor Units

Wall Mounted Type FTXS 25/35 E

Accessories
A Mounting plate

Mounting plate fixing


screws M4 25L
Titanium
Apatite Photocatalytic
C
Air-Purifying Filter
B

D Wireless remote controller

Insulation tape

K Operation manual

G AAA dry-cell batteries

L Installation manual

Indoor unit fixing screws


H
M4 12L

E Remote controller holder

2
1

Fixing screws for remote


controller holder M3 20L

3
Choosing an Installation Site
Before choosing the installation site, obtain user approval.

1.

Indoor unit.

1)
2)
3)
4)
5)
6)
7)
8)
9)

2.

The indoor unit should be sited in a place where:


the restrictions on installation specified in the indoor unit installation drawings are met,
both air intake and exhaust have clear paths met,
the unit is not in the path of direct sunlight,
the unit is away from the source of heat or steam,
there is no source of machine oil vapour (this may shorten indoor unit life),
cool (warm) air is circulated throughout the room,
the unit is away from electronic ignition type fluorescent lamps (inverter or rapid start type) as they may shorten the remote controller range,
the unit is at least 1 metre away from any television or radio set (unit may cause interference with the picture or sound),
install at the recommended height (1.8m).

Wireless remote controller.


1) Turn on all the fluorescent lamps in the room, if any, and find the site where remote controller signals are
properly received by the indoor unit (within 7 metres).

Installation Tips
<When there is no work space because the unit is close to ceiling>

1. Removing and installing front panel.

Removal method
Hook fingers on the panel protrusions on the left and right
of the main body, and open until the panel stops. Slide
the front panel sideways to disengage
the rotating shaft. Then pull
the front panel toward you
to remove it.

CAUTION
1) Push up.

Be sure to wear protection gloves.


Place both hands under the center of the front
grille, and while pushing up, pull it toward you.

2) Pull toward you.

Installation method
1) Install the front grille and firmly engage the upper hooks (3 locations).
2) Install 2 screws of the front grille.
3) Install the air filter and then mount the front panel.

Installation method

2. Removing and installing front grille.

Removal method

mark area
(3 locations)

Upper hook

1)Remove front panel to remove the air filter.


2)Remove the front grille.
mark of the
3)In front of the
front grille, there are 3 upper
hooks. Lightly pull the front grille
pull the front
toward you with one hand, and Lightly
grille toward you with
one hand, and push
push down on the hooks with
down on the hooks with
fingers of your other
the fingers of your other hand. the
hand. (3 locations)

Push
down.

Upper hook

Upper hook

When two indoor units are


installed in one room, the
two wireless remote
controllers can be set for
different addresses.
1) In the same way as
when connecting to an
HA system, remove the
metal plate electrical
wiring cover.
2) Cut the address jumper
(JA) on the printed
circuit board.
3) Cut the address jumper
(J4) in the remote
controller.

ADDRESS

3. How to set the


different addresses.

Push the
rotating shaft
of the front
panel into the
groove.

JA

Align the tabs of the front panel with the


grooves, and push all the way in. Then
close slowly. Push the center of the
lower surface of the panel firmly to
engage the tabs.

JA ADDRESS
EXIST
CUT

1
2

J4

J4 ADDRESS
EXIST
CUT

Installation Manual

1
2

189

Indoor Units

EDAU12-722

Indoor Unit Installation Drawings


How to attach the indoor unit.
Hook the claws of the bottom frame
to the mounting plate.
If the claws are difficult to hook,
remove the front grille.
How to remove the indoor unit.
Push up the marked area (at the
lower part of the front grille) to
release the claws. If it is difficult to Front grille
release, remove the front grille.

A Mounting plate

A Mounting
plate

Clip

Bottom frame

Mark (rear side)

The mounting plate


should be installed on a
wall which can support the
weight of the indoor unit.
B Mounting plate fixing
screws M4 25L (6)

Caulk
pipe hole
gap
with putty.

30mm or more from ceiling

Cut thermal insulation


pipe to an appropriate
length and wrap it with
tape, making sure that no
gap is left in the insulation
pipes cut line.

Front panel
Wrap the insulation pipe with
the finishing tape from bottom
to top.

50mm or more from walls


(on both sides)

Intelligent-eye sensor

M4 16L

Air filters

Service lid
Opening service lid
Service lid is opening/closing type.
Opening method
1) Remove the service lid screws.
2) Pull out the service lid diagonally
down in the direction of the arrow.
3) Pull down.

C Titanium Apatite Photocatalytic


Air-Purifying Filter (2)
C Titanium Apatite
Photocatalytic
Air-Purifying Filter
Air filter
Filter frame
D Wireless
remote controller
Tab

F Fixing screws for


remote controller
holder M3 20L (2)

Before screwing the remote


controller holder to the wall,
make sure that control
signals are properly
received by indoor unit.
E
Remote
controller holder

Intelligent-eye Sensor
CAUTION
1) Do not hit or violently push the intelligent-eye sensor. This can lead to damage and malfunction.
2) Do not place large objects near the sensor. Also keep heating units or humidifiers outside the
sensors detection area.

190

Installation Manual

EDAU12-722

Indoor Units

Indoor Unit Installation (1)


1.

Installing the mounting plate.


The mounting plate should be installed on a wall which can support the weight of the indoor unit.
1) Temporarily secure the mounting plate to the wall, make sure that the panel is completely level, and
mark the boring points on the wall.
2) Secure the mounting plate to the wall with screws.
Recommended mounting plate retention spots and dimensions

3
450

Recommended
mounting plate
retention spots
(6 spots in all)

100

400

(Bolt size : M10)

135

110
65
60

65
130
220

60

44.5

Use tape
measure
as shown.
Position the
end of a tape
measure at .

131.5
44.5 87

283

47.5

46.5

(Bolt size : M10)

50.5

80

141.5

Place a leveler
on raised tab.

110

50
800

Drain hose
position

Throughthe-wall
hole 65mm

Liquid pipe end Keep here the piece cut out


from the unit for piping
Gas pipe end

* The removed pipe port cover can be


kept in the mounting plate pocket.

Removed pipe
port cover

A Mounting plate

2.

Boring a wall hole and installing wall embedded pipe.


For walls containing metal frame or metal board, be sure to use a wall
embedded pipe and wall cover in the feed-through hole to prevent
possible heat, electrical shock, or fire.
Be sure to caulk the gaps around the pipes with caulking material to
prevent water leakage.
1) Bore a feed-through hole of 65mm in the wall so it has a down slope
toward the outside.
2) Insert a wall pipe into the hole.
3) Insert a wall cover into wall pipe.
4) After completing refrigerant piping, wiring, and drain piping, caulk pipe
hole gap with putty.

Installation Manual

Inside
Wall embedded pipe
(Field supply)

Outside
Caulking

65

Wall hole cover


(Field supply)
Wall embedded pipe
(Field supply)

191

Indoor Units

EDAU12-722

Indoor Unit Installation (2)


3.

Installing indoor unit.


3-1. Right-side, right-back, or right-bottom piping.
1) Attach the drain hose to the underside of the refrigerant pipes
with an adhesive vinyl tape.
2) Wrap the refrigerant pipes and drain hose together with an
insulation tape.

Right-back piping

Remove pipe port cover


here for right-side piping.

Right-bottom
piping

Bind coolant pipe


and drain hose
together with
insulating tape.

Remove pipe port cover


here for right-bottom piping.

A Mounting plate

3) Pass the drain hose and refrigerant pipes through the wall
hole, then set the indoor unit on the mounting plate hooks by
using the markings at the top of the indoor unit as a guide.
4) Open the front panel, then open the service lid. (Refer to
Installation Tips.)
5) Pass the interconnecting wires from the outdoor unit through
the feed-through wall hole and then through the back of the
indoor unit. Pull them through the front side.
Bend the ends of tie wires upward for easier work in advance.
(If the interconnecting wire ends are to be stripped first, bundle
wire ends with adhesive tape.)
6) Press the bottom frame of the indoor unit with both hands to
set it on the mounting plate hooks. Make sure that the wires do
not catch on the edge of the indoor unit.

Hang indoor units hook here.

A Mounting plate
When stripping the
ends of interconnecting
wires in advance, bind
right ends of wires with
insulating tape.

Interconnecting
wires
Wire guide

3-2. Left-side, left-back, or left-bottom piping.


1) Attach the drain hose to the underside of the refrigerant pipes
with adhesive vinyl tape.

Remove pipe
port cover
here for leftside piping.
Left-side
piping
Left-back
piping

Remove pipe port cover here for left-bottom piping.


Left-bottom piping

2) Be sure to connect the drain hose to the drain port in place of


a drain plug.

3) Shape the refrigerant pipe along the pipe path


marking on the mounting plate.
4) Pass drain hose and refrigerant pipes through
the wall hole, then set the indoor unit on
Drain
hose
mounting plate hooks, using the markings at
Caulk this hole
with putty or
the top of indoor unit as a guide.
caulking material.
5) Pull in the interconnecting wires.
6) Connect the inter-unit piping.
7) Wrap the refrigerant pipes and drain hose together with
insulation tape as right figure, in case of setting the drain hose
through the back of the indoor unit.
8) While exercising care so that the interconnecting wires do not catch
indoor unit, press the bottom edge of indoor unit with both hands until
it is firmly caught by the mounting plate hooks. Secure indoor unit to
the mounting plate with the screws (M4 12L).
3-3. Wall embedded piping.
Follow the instructions given under
Left-side, left-back, or left-bottom piping
1) Insert the drain hose to this depth so it wont be pulled out of
the drain pipe.

192

How to set drain plug


p

a
No g

Do not apply lubricating


oil (refrigerant machine
oil) when inserting.
Application of causes
deterioration and drain
leakage of the plug.
Insert a hexagon wrench (4mm)

A Mounting plate

Bind with plastic


tape.

Wrap insulating tape around the


bent portion of refrigerant pipe.
Overlap at least half the width
of the tape with each turn.

Drain hose

A
Mounting
plate
Refrigerant
pipes

Bottom frame
H M4 12L (2 point)

Insert drain hose


to this depth so
it wont be pulled
out of drain pipe.

50mm
or more

Outer wall

Inner wall

Drain hose
Vinyl chloride
drain pipe
(VP-30)

Installation Manual

EDAU12-722

Indoor Units

Indoor Unit Installation (3)


With a multi indoor unit

4.

, install as described in the installation manual supplied with the Multi outdoor unit.
Terminal block

Wiring.
1) Strip wire ends (15mm).
2) Match wire colours with terminal numbers on indoor and outdoor units
terminal blocks and firmly screw wires to the corresponding terminals.
3) Connect the earth wires to the corresponding terminals.
Attach the earth wire so that it is not connected to the fan
motor connector.
4) Pull wires to make sure that they are securely latched up,
then retain wires with wire retainer.
5) In case of connecting to an adapter system. Run the remote
controller cable and attach the S21.
(Refer to 5. When connecting to an HA system.)
6) Shape the wires so that the service lid fits securely, then close service lid.

Electrical component box


Shape wires so that the service lid
will fit securely.
Connector for fan motor
Firmly secure wire retainer so that
wires sustain no external stress.
Wire retainer
Use the
specified wire type.

Firmly fix the wires with


the terminal screws.

3
Outdoor unit
1 23

When wire length exceeds


10m, use 2.0mm diameter wires.

Indoor
unit

LN

1
2
3

Firmly fix the wires with


the terminal screws.

H05VV

WARNING
1) Do not use tapped wires, stranded wires, extensioncords, or starburst connections, as they may cause
overtheating, electrical shock,or fire.
2) Do not use locally purchased electrical parts inside the product. (Do not branch the power for the drain pump, etc.,
from the terminal block.) Doing so may cause electric shock or fire.

5.

When connecting to an HA system.


1) Remove the front grille.
Tab
(2 screws)
Notched part
Push
2) Remove the electrical
Slide
wiring box. (1 screw)
3) Remove the metal plate
HA connector
(S21)
electrical wiring cover.
(3 tabs)
Slide
4) Attach the connection
4) Attach the connection cord to
cord to the S21 connector 3) Remove the metal Screw
Pull
the S21 connector and pull the
plate electrical
Tab
harness out through the
wiring cover.
and pull the harness out
notched part in the figure.
through the notched part
in the figure.
5) Replace the electrical wiring cover as it was, and pull the harness
around, as shown in the figure.

5) Replace the electrical


wiring cover as it was,
and pull the harness
around, as shown
in the figure.

Drain piping.
1) Connect the drain hose, as described below.
The drain hose should
be inclined downward.

3) When drain hose requires extension, obtain


an extension hose commercially available.
Be sure to thermally insulate the indoor
section of the extension hose.

No trap is permitted.

Indoor unit
drain hose

18

6.

HA cord

Extension drain hose

Do not put the end


of the hose in water.
Heat insulation tube
(Field supply)

4) When connecting a rigid polyvinyl chloride pipe


(nominal diameter 13mm) directly to the drain
hose attached to the indoor unit as with embedded
piping work, use any commercially available drain
socket (nominal diameter 13mm) as a joint.
18

2) Remove the air filters and pour some water


into the drain pan to check the water flows
smoothly.

Drain hose supplied with


the indoor unit

Installation Manual

Commercially available drain


socket
(nominal diameter 13mm)

Commercially available rigid


polyvinyl chloride pipe
(nominal diameter 13mm)

193

Indoor Units

EDAU12-722

Refrigerant Piping Work


With a multi indoor unit

1.

, install as described in the installation manual supplied with the Multi outdoor unit.

Flaring the pipe end.


1) Cut the pipe end with a pipe cutter.
2) Remove burrs with the cut surface facing
downward so that the chips do not enter
the pipe.
3) Put the flare nut on the pipe.
4) Flare the pipe.
5) Check that the flaring is properly made.

(Cut exactly at
right angles.)

Remove burrs

Flaring
Set exactly at the position shown below.
A

Die

Flare tool for R410A

Conventional flare tool

Clutch-type

Clutch-type (Rigid-type) Wing-nut type (Imperial-type)

0-0.5mm

1.0-1.5mm

1.5-2.0mm

Check
Flares inner
surface must
be flaw-free.

The pipe end must


be evenly flared in
a perfect circle.
Make sure that the
flare nut is fitted.

WARNING
1) Do not use mineral oil on flared part.
2) Prevent mineral oil from getting into the system as this would reduce the lifetime of the units.
3) Never use piping which has been used for previous installations. Only use parts which are delivered
with the unit.
4) Do never install a drier to this R410A unit in order to guarantee its lifetime.
5) The drying material may dissolve and damage the system.
6) Incomplete flaring may cause refrigerant gas leakage.

2.

Refrigerant piping.
1) Align the centres of both flares and tighten the flare nuts 3 or 4
turns by hand. Then tighten them fully with the torque wrenches.
Use torque wrenches when tightening the flare nuts to prevent
damage to the flare nuts and escaping gas.
Torque wrench

Coat here with refrigeration machine oil

Flare nut tightening torque


Liquid side

Gas side
3/8 inch

1/4 inch

32.7-39.9N m

14.2-17.2N m

(330-407kgf cm)

(144-175kgf cm)

Spanner

Piping union
Flare nut

2) To prevent gas leakage, apply refrigeration machine oil on both inner and outer surfaces of the flare.
(Use refrigeration oil for R410A)
2-1. Caution on piping handling.
1) Protect the open end of the pipe against dust and moisture.
2) All pipe bends should be as gentle as possible. Use a
Rain
pipe bender for bending.
(Bending radius should be 30 to 40mm or larger.)
2-2. Selection of copper and heat insulation materials.
When using commercial copper pipes and fittings, observe the following:
1) Insulation material: Polyethylene foam
Heat transfer rate: 0.041 to 0.052W/mK (0.035 to 0.045kcal/(mh C))
Refrigerant gas pipes surface temperature reaches 110C max.
Choose heat insulation materials that will withstand this temperature.
2) Be sure to insulate both the gas and liquid piping and to provide
insulation dimensions as below.
Gas side
25/35 class
O.D. 9.5mm

Liquid side
O.D. 6.4mm

Thickness 0.8mm

Gas pipe thermal insulation


25/35 class

Liquid pipe thermal


insulation

I.D. 12-15mm

I.D. 8-10mm

Wall

Be sure to
place a cap.
If no flare cap is
available, cover
the flare mouth
with tape to keep
dirt or water out.

Inter-unit wiring
Gas pipe

Gas pipe
insulation

Liquid pipe

Liquid pipe
insulation
Finishing tape

Drain hose

Thickness 10mm Min.

3) Use separate thermal insulation pipes for gas and liquid refrigerant pipes.

194

Installation Manual

EDAU12-722

Indoor Units

Trial Operation and Testing


1.

Trial operation and testing.


1-1 Measure the supply voltage and make sure that it falls in the specified range.
1-2 Trial operation should be carried out in either cooling or heating mode.
For Heat pump

In cooling mode, select the lowest programmable temperature; in heating mode, select the highest
programmable temperature.
1) Trial operation may be disabled in either mode depending on the room temperature.
Use the remote controller for trial operation as described below.
2) After trial operation is complete, set the temperature to a normal level (26C to 28C in cooling mode,
20C to 24C in heating mode).
3) For protection, the system disables restart operation for 3 minutes after it is turned off.

For Cooling only

Select the lowest programmable temperature.


1) Trial operation in cooling mode may be disabled depending on the room temperature.
Use the remote controller for trial operation as described below.
2) After trial operation is complete, set the temperature to a normal level (26C to 28C).
3) For protection, the system disables restart operation for 3 minutes after it is turned off.

1-3 Carry out the test operation in accordance with the operation manual to ensure that all functions and
parts, such as louver movement, are working properly.
The air conditioner requires a small amount of power in its standby mode. If the system is not to be used for
some time after installation, shut off the circuit breaker to eliminate unnecessary power consumption.

If the circuit breaker trips to shut off the power to the air conditioner, the system will restore the original
operation mode when the circuit breaker is opened again.

Trial operation from remote controller.


1) Press ON/OFF button to turn on the system.
2) Simultaneously press centre of TEMP button and MODE button.
3) Press MODE button twice.
( will appear on the display to indicate that Trial Operation mode is selected.)
4) Trial run mode terminates in approx. 30 minutes and switches into normal mode. To quit a trial
operation, press ON/OFF button.

2.

Test items.
Test items

Symptom
(diagnostic display on RC)

Indoor and outdoor units are installed properly on


solid bases.

Fall, vibration, noise

No refrigerant gas leaks.

Incomplete cooling/heating function

Refrigerant gas and liquid pipes and indoor drain


hose extension are thermally insulated.

Water leakage

Draining line is properly installed.

Water leakage

System is properly earthed.

Electrical leakage

The specified wires are used for interconnecting


wire connections.

Inoperative or burn damage

Indoor or outdoor units air intake or exhaust has


clear path of air. Shut-off valves are opened.

Incomplete cooling/heating function

Indoor unit properly receives remote controller


commands.

Inoperative

Check

3P175978-5B

Installation Manual

195

Indoor Units

1.4

EDAU12-722

Wall Mounted Type FTXS 50/60/70 F

Accessories
A Mounting plate
B

Mounting plate fixing


screws M4 25L

D Wireless remote controller

Indoor unit fixing screws


M4 12L

E Remote controller holder

Insulation tape

Fixing screws for remote


F
controller holder M3 20L

K Operation manual

G AAA dry-cell batteries

L Installation manual

C Titanium Apatite

Photocatalytic
Air-Purifying Filter

Choosing an Installation Site


Before choosing the installation site, obtain user approval.

1.

Indoor unit.

1)
2)
3)
4)
5)
6)
7)
8)
9)

2.

The indoor unit should be sited in a place where:


the restrictions on installation specified in the indoor unit installation drawings are met,
both air intake and exhaust have clear paths met,
the unit is not in the path of direct sunlight,
the unit is away from the source of heat or steam,
there is no source of machine oil vapour (this may shorten indoor unit life),
cool (warm) air is circulated throughout the room,
the unit is away from electronic ignition type fluorescent lamps (inverter or rapid start type) as they may shorten the remote controller range,
the unit is at least 1 metre away from any television or radio set (unit may cause interference with the picture or sound),
install at the recommended height (1.8m).

Wireless remote controller.


1) Turn on all the fluorescent lamps in the room, if any, and find the site where remote controller signals are
properly received by the indoor unit (within 7 metres).

Installation Tips
<When there is no work space because the unit is close to ceiling>

1. Removing and installing front panel.

Removal method
Hook fingers on the panel protrusions on the left and right
of the main body, and open until the panel stops. Slide
the front panel sideways to disengage
the rotating shaft. Then pull
the front panel toward you
to remove it.

CAUTION

1) Push up.

Be sure to wear protection gloves.

Place both hands under the center of the front


grille, and while pushing up, pull it toward you.

2) Pull toward you.

Installation method
1) Install the front grille and firmly engage the upper hooks (3 locations).
2) Install 3 screws of the front grille.
3) Install the air filter and then mount the front panel.

Installation method
Push the
rotating shaft
of the front
panel into the
groove.

2. Removing and installing front grille.

Removal method
1)Remove front panel to remove
the air filter.
2) Remove the front grille.
3) In front of the
mark of
the front grille, there are 3
upper hooks. Lightly pull the
front grille toward you with one
hand, and push down on the
hooks with the fingers of your
other hand.

196

Upper hook

Lightly pull the front grille


toward you with one
hand, and push down on
the hooks with the fingers
of your other hand.
(3 locations)

mark area
(3 locations)

Push
down.

Upper hook

Upper hook

When two indoor units are


installed in one room, the
two wireless remote
controllers can be set for
different addresses.
1) In the same way as when
connecting to an HA
system, remove the metal
plate electrical wiring
cover.
2) Cut the address jumper
(JA) on the prindted
circuit board.
3) Cut the address jumper
(J4) in the remote
controller.

ADDRESS

3. How to set the different


addresses.

JA

Align the tabs of the front panel with


the grooves, and push all the way in.
Then close slowly. Push the center of
the lower surface of the panel firmly to
engage the tabs.

JA ADDRESS
EXIST
CUT

1
2

J4

J4 ADDRESS
EXIST
CUT

1
2

Installation Manual

EDAU12-722

Indoor Units

Indoor Unit Installation Drawings


How to attach the indoor unit.
Hook the claws of the bottom frame
to the mounting plate.
If the claws are difficult to hook,
remove the front grille.

A Mounting plate

How to remove the indoor unit.


Push up the marked area (at the
lower part of the front grille) to
release the claws. If it is difficult to
release, remove the front grille.

A Mounting
plate
Clip
Bottom frame

Front grille

Mark (rear side)

3
The mounting plate
should be installed on a
wall which can support the
weight of the indoor unit.

B Mounting plate fixing


screws M4 25L (9)

Caulk
pipe hole
gap
with putty.

30mm or more from ceiling

Cut thermal insulation


pipe to an appropriate
length and wrap it with
tape, making sure that no
gap is left in the insulation
pipes cut line.

Front panel
Wrap the insulation pipe with
the finishing tape from bottom
to top.

50mm or more from walls


(on both sides)

Air filters

Intelligent-eye sensor
(FTXS, FTKS only)
M4 16L

C Titanium Apatite Photocatalytic


Air-Purifying Filter (2)

Service lid
Opening service lid
Service lid is opening/closing type.
Opening method
1) Remove the service lid screws.
2) Pull out the service lid diagonally
down in the direction of the arrow.
3) Pull down.

Tabs (upper 3 locations)

Tabs (lower 3 locations)


Insert the upper side of the C Titanium
Apatite Photocatalytic Air-purifying filter into
the tabs (upper 3 locations),push the lower
side of the filters up a little and into the tabs
(lower 3 locations).

D Wireless
remote controller

F Fixing screws for


remote controller
holder M3 20L (2)

Before screwing the remote


controller holder to the wall,
make sure that control
signals are properly
received by indoor unit.
E
Remote
controller holder

Intelligent-eye Sensor (FTXS, FTKS only)


CAUTION
1) Do not hit or violently push the intelligent-eye sensor. This can lead to damage and malfunction.
2) Do not place large objects near the sensor. Also keep heating units or humidifiers outside the
sensors detection area.

Installation Manual

197

Indoor Units

EDAU12-722

Indoor Unit Installation (1)


1.

Installing the mounting plate.


The mounting plate should be installed on a wall which can support the weight of the indoor unit.
1) Temporarily secure the mounting plate to the wall, make sure that the panel is completely level, and
mark the boring points on the wall.
2) Secure the mounting plate to the wall with screws.
Recommended mounting plate retention spots and dimensions

Recommended mounting plate retention


spots (9 spots in all)
Place a leveler on raised tab.
(Bolt size : M10)

(Bolt size : M10)

100
55

125

90

290

Use tape
measure
as shown.
Position the
end of a tape
measure at .

80

52

52

80
60

83

413.5

44.5

100

99.5

1050
Through-the-wall
Drain hose position hole 80mm

* The removed pipe port cover can be


kept in the mounting plate pocket.

Keep here the piece cut out


from the unit for piping

Gas pipe end


Liquid pipe end

(length: mm)

Removed pipe
port cover

A Mounting plate

2.

Boring a wall hole and installing wall embedded pipe.


For walls containing metal frame or metal board, be sure to use a wall
embedded pipe and wall cover in the feed-through hole to prevent
possible heat, electrical shock, or fire.
Be sure to caulk the gaps around the pipes with caulking material to
prevent water leakage.
1) Bore a feed-through hole of 80mm in the wall so it has a down slope
toward the outside.
2) Insert a wall pipe into the hole.
3) Insert a wall cover into wall pipe.
4) After completing refrigerant piping, wiring, and drain piping, caulk pipe
hole gap with putty.

198

Inside
Wall embedded pipe
(Field supply)

Wall hole cover


(Field supply)

Outside
Caulking

80
Wall embedded pipe
(Field supply)

Installation Manual

EDAU12-722

Indoor Units

Indoor Unit Installation (2)


3.

Installing indoor unit.


3-1. Right-side, right-back, or right-bottom piping.
1) Attach the drain hose to the underside of the refrigerant pipes
with an adhesive vinyl tape.
2) Wrap the refrigerant pipes and drain hose together with an
insulation tape.

Remove pipe port cover


here for right-side piping.

Right-back piping
Right-bottom
piping

Remove pipe port cover


here for right-bottom piping.

Hang indoor units hook here.

When stripping the


ends of inter-unit wiring
in advance, bind right
ends of wires with
insulating tape.
Wire guide

Remove pipe port


cover here for
left-side piping.
Left-side
piping

Remove pipe port cover here for left-bottom piping.


Left-bottom piping

3) Shape the refrigerant pipe along the pipe path


marking on the mounting plate.
4) Pass drain hose and refrigerant pipes through
the wall hole, then set the indoor unit on
Drain
hose
mounting plate hooks, using the markings at
Caulk this hole
the top of indoor unit as a guide.
with putty or
caulking material.
5) Pull in the inter-unit wiring.
6) Connect the inter-unit piping.
7) Wrap the refrigerant pipes and drain hose together with
insulation tape as right figure, in case of setting the drain hose
through the back of the indoor unit.
8) While exercising care so that the inter-unit wiring do not catch
indoor unit, press the bottom edge of indoor unit with both hands
until it is firmly caught by the mounting plate hooks. Secure
indoor unit to the mounting plate with the screws (M4 12L).
3-3. Wall embedded piping.
Follow the instructions given under
Left-side, left-back, or left-bottom piping .
1) Insert the drain hose to this depth so it wont be pulled out of
the drain pipe.

Installation Manual

Mounting plate

Inter-unit wiring

3-2. Left-side, left-back, or left-bottom piping.


1) Attach the drain hose to the underside of the refrigerant pipes
with adhesive vinyl tape.
2) Be sure to connect the drain hose to the drain port in place of
a drain plug.

A Mounting plate

3) Pass the drain hose and refrigerant pipes through the wall
hole, then set the indoor unit on the mounting plate hooks by
using the markings at the top of the indoor unit as a guide.
4) Open the front panel, then open the service lid. (Refer to
Installation Tips.)
5) Pass the inter-unit wiring from the outdoor unit through the
feed-through wall hole and then through the back of the indoor
unit. Pull them through the front side.
Bend the ends of tie wires upward for easier work in advance.
(If the inter-unit wiring ends are to be stripped first, bundle wire
ends with adhesive tape.)
6) Press the bottom frame of the indoor unit with both hands to
set it on the mounting plate hooks. Make sure that the wires do
not catch on the edge of the indoor unit.

Bind coolant pipe


and drain hose
together with
insulating tape.

Left-back
piping

How to set drain plug


ap
No g

Do not apply lubricating


oil (refrigerant oil) when
inserting.
Application of causes
deterioration and drain
leakage of the plug.
Insert a hexagon wrench (4mm)

A Mounting plate

Bind with plastic


tape.

Wrap insulating tape around the


bent portion of refrigerant pipe.
Overlap at least half the width
of the tape with each turn.

Drain hose

Mounting
plate
Refrigerant
pipes

Bottom frame
H M4 12L (2 point)

Insert drain hose to this


depth so it wont be
pulled out of drain pipe.

Inner wall

50mm
or more

Drain hose

Outer wall

Vinyl chloride
drain pipe
(VP-30)

199

Indoor Units

EDAU12-722

Indoor Unit Installation (3)


4.

Wiring.
With a Multi indoor unit , install as described in the installation
manual supplied with the Multi outdoor unit.
1) Strip wire ends (15mm).
2) Match wire colours with terminal numbers on indoor and
outdoor units terminal blocks and firmly screw wires to the
corresponding terminals.
3) Connect the earth wires to the corresponding terminals.
4) Pull wires to make sure that they are securely latched up,
then retain wires with wire retainer.
5) In case of connecting to an adapter system. Run the remote
controller cable and attach the S21. (Refer to 5. When
connecting to an HA system.)
6) Shape the wires so that the service lid fits securely, then close
service lid.

Terminal block
Electrical component box
Shape wires so
that the service
lid will fit securely.

Use the
specified
wire type.

Firmly secure wire retainer


so that wires sustain no
external stress.
Wire retainer

Firmly fix the wires with


the terminal screws.

Outdoor unit
1 23

When wire length exceeds


10m, use 2.0mm diameter wires.

Indoor
unit

LN

1
2
3

Firmly fix the wires with


the terminal screws.

H05VV

WARNING
1) Do not use tapped wires, stranded wires, extensioncords, or starburst connections, as they may cause
overtheating, electrical shock,or fire.
2) Do not use locally purchased electrical parts inside the product. (Do not branch the power for the drain pump, etc.,
from the terminal block.) Doing so may cause electric shock or fire.

5.

When connecting to an HA system.


1) Remove the front grille.
Tab
Push
(3 screws)
Notched part
Tab
Push
2) Remove the electrical
wiring box. (1 screw)
Slide
3) Remove the metal plate
HA connector
Main body
(S21)
electrical wiring cover.
(4 tabs)
Metal plate
4) Attach the connection
electrical cover
Screw
4) Attach the connection cord to
Push
cord to the S21 connector 3) Remove the metal
the S21 connector and pull the
plate electrical
Tab
harness out through the
wiring cover.
and pull the harness out
notched part in the figure.
through the notched part
in the figure.
5) Replace the electrical wiring cover as it was, and pull the harness
around, as shown in the figure.

5) Replace the electrical


wiring cover as it was,
and pull the harness
around, as shown
in the figure.

Drain piping.
1) Connect the drain hose, as described below.
The drain hose should
be inclined downward.

3) When drain hose requires extension, obtain


an extension hose commercially available.
Be sure to thermally insulate the indoor
section of the extension hose.

No trap is permitted.

Indoor unit
drain hose

18

6.

HA cord

Extension drain hose

Do not put the end


of the hose in water.
Heat insulation tube
(Field supply)

4) When connecting a rigid polyvinyl chloride pipe


(nominal diameter 13mm) directly to the drain
hose attached to the indoor unit as with embedded
piping work, use any commercially available drain
socket (nominal diameter 13mm) as a joint.
18

2) Remove the air filters and pour some water


into the drain pan to check the water flows
smoothly.

Drain hose supplied with


the indoor unit

200

Commercially available drain


socket
(nominal diameter 13mm)

Commercially available rigid


polyvinyl chloride pipe
(nominal diameter 13mm)

Installation Manual

EDAU12-722

Indoor Units

Refrigerant Piping Work


With a Multi indoor unit

1.

, install as described in the installation manual supplied with the Multi outdoor unit.

Flaring the pipe end.


1) Cut the pipe end with a pipe cutter.
2) Remove burrs with the cut surface facing
downward so that the chips do not enter the
pipe.
3) Put the flare nut on the pipe.
4) Flare the pipe.
5) Check that the flaring is properly made.

(Cut exactly at
right angles.)

Remove burrs

Flaring
Set exactly at the position shown below.
A

Die

Flare tool for R410A

Conventional flare tool

Clutch-type

Clutch-type (Rigid-type) Wing-nut type (Imperial-type)

0-0.5mm

1.0-1.5mm

1.5-2.0mm

Check

The pipe end must


be evenly flared in
a perfect circle.

Flares inner
surface must
be flaw-free.

Make sure that the


flare nut is fitted.

WARNING
1) Do not use mineral oil on flared part.
2) Prevent mineral oil from getting into the system as this would reduce the lifetime of the units.
3) Never use piping which has been used for previous installations. Only use parts which are delivered
with the unit.
4) Do never install a drier to this R410A unit in order to guarantee its lifetime.
5) The drying material may dissolve and damage the system.
6) Incomplete flaring may cause refrigerant gas leakage.

2.

Refrigerant piping.
1) Align the centres of both flares and tighten the flare nuts 3 or 4
turns by hand. Then tighten them fully with the torque wrenches.
Use torque wrenches when tightening the flare nuts to
prevent damage to the flare nuts and escaping gas.
Torque wrench

Coat here with refrigeration oil

Flare nut tightening torque


Gas side

Liquid side

1/2 inch

5/8 inch

1/4 inch

49.5-60.3N m

61.8-75.4N m

14.2-17.2N m

(505-615kgf cm) (630-770kgf cm)

(144-175kgf cm)

Spanner

Piping union
Flare nut

2) To prevent gas leakage, apply refrigeration oil on both inner and outer surfaces of the flare.
(Use refrigeration oil for R410A.)
2-1. Caution on piping handling.
1) Protect the open end of the pipe against dust and moisture. Rain
2) All pipe bends should be as gentle as possible. Use a
pipe bender for bending.
(Bending radius should be 30 to 40mm or larger.)
2-2. Selection of copper and heat insulation materials.
When using commercial copper pipes and fittings, observe the following:
1) Insulation material: Polyethylene foam
Heat transfer rate: 0.041 to 0.052W/mK (0.035 to 0.045kcal/(mh C))
Refrigerant gas pipes surface temperature reaches 110C max.
Choose heat insulation materials that will withstand this temperature.
2) Be sure to insulate both the gas and liquid piping and to provide
insulation dimensions as below.
Gas side

Liquid side

Wall

Be sure to
place a cap.
If no flare cap is
available, cover
the flare mouth
with tape to keep
dirt or water out.

Inter-unit wiring
Gas pipe

Liquid pipe

Gas pipe
insulation

Gas pipe thermal insulation

Liquid pipe
insulation
Finishing tape

Drain hose

Liquid pipe thermal insulation

50/60 class

71/80/90 class

50/60/71/80/90 classs

50/60 class

71/80/90 class

50/60/71/80/90 class

O.D. 12.7mm

O.D. 15.9mm

O.D. 6.4mm

I.D. 14-16mm

I.D. 16-20mm

I.D. 8-10mm

Thickness 0.8mm Thickness 1.0mm

Thickness 0.8mm

Thickness 10mm Min.

3) Use separate thermal insulation pipes for gas and liquid refrigerant pipes.

Installation Manual

201

Indoor Units

EDAU12-722

Trial Operation and Testing


1.

Trial operation and testing.


1-1 Measure the supply voltage and make sure that it falls in the specified range.
1-2 Trial operation should be carried out in either cooling or heating mode.
For Heat pump

In cooling mode, select the lowest programmable temperature; in heating mode, select the highest
programmable temperature.
1) Trial operation may be disabled in either mode depending on the room temperature.
Use the remote controller for trial operation as described below.
2) After trial operation is complete, set the temperature to a normal level (26C to 28C in cooling mode,
20C to 24C in heating mode).
3) For protection, the system disables restart operation for 3 minutes after it is turned off.
For Cooling only

Select the lowest programmable temperature.


1) Trial operation in cooling mode may be disabled depending on the room temperature.
Use the remote controller for trial operation as described below.
2) After trial operation is complete, set the temperature to a normal level (26C to 28C).
3) For protection, the system disables restart operation for 3 minutes after it is turned off.

1-3 Carry out the test operation in accordance with the operation manual to ensure that all functions and
parts, such as louver movement, are working properly.
The air conditioner requires a small amount of power in its standby mode. If the system is not to be used for
some time after installation, shut off the circuit breaker to eliminate unnecessary power consumption.

If the circuit breaker trips to shut off the power to the air conditioner, the system will restore the original
operation mode when the circuit breaker is opened again.

Trial operation from remote controller.


1) Press ON/OFF button to turn on the system.
2) Simultaneously press centre of TEMP button and MODE button.
3) Press MODE button twice.
( will appear on the display to indicate that Trial Operation mode is selected.)
4) Trial run mode terminates in approx. 30 minutes and switches into normal mode. To quit a trial
operation, press ON/OFF button.

2.

Test items.
Test items

Symptom
(diagnostic display on RC)

Indoor and outdoor units are installed properly on


solid bases.

Fall, vibration, noise

No refrigerant gas leaks.

Incomplete cooling/heating function

Refrigerant gas and liquid pipes and indoor drain


hose extension are thermally insulated.

Water leakage

Draining line is properly installed.

Water leakage

System is properly earthed.

Electrical leakage

The specified wires are used for inter-unit wiring


connections.

Inoperative or burn damage

Indoor or outdoor units air intake or exhaust has


clear path of air. Stop valves are opened.

Incomplete cooling/heating function

Indoor unit properly receives remote controller


commands.

Inoperative

Check

3P182980-4

202

Installation Manual

EDAU12-722

1.5

Indoor Units

Duct Connected Type FDXS 25/35/50/60 C

ACCESSORIES
Clamp metal

Insulation
for fitting

1 pc.

1 each

for gas pipe

Sealing pad
Large and small
3 pcs.
1 each
(only for 50-60 type)

Washer for
Drain hose hanging bracket Sealing material

Clamp

Washer
fixing plate

8 pcs.

6 pcs.

1 set

1 pc.

1 pc.

2 pc.

2 large
Large
1 small

Hanger (right)
insulation
4 pcs.

for liquid pipe

Screws for
duct flanges

Air fillter

1 set

1 pc.

Small

Stored in outlet vent

Wireless
Remote controller
AAA
remote controller
holder
dry-cell batteries
1 pc.

1 set

1 pc.

Reciever kit
1 pc.

1 pc.

Mounting frame

24 pcs.

Decorative
cover

[ Other ]

2 pcs.

Operation
manual
Installation
manual

Screws
M4 25

2 pcs.

CHOOSING A SITE
Before choosing the installation site, obtain user approval.

Indoor unit
CAUTION
When moving the unit during or after unpacking, make sure to lift it by holding its lifting lugs. Do not exert any pressure on other
parts, especially the refrigerant piping, drain piping and flange parts.
Wear protective gears (gloves and so on) when installing the unit.
If you think the humidity inside the ceiling might exceed 30C and RH80%, reinforce the insulation on the unit body.
Use glass wool or polyethylene foam as insulation so that the thickness is more than 10mm and fits inside the ceiling opening.

Select the signal receiver mounting location according to the following conditions:
Install the signal receiver, which has a built-in temperature sensor, near the intake vent where there is convection of air
and it can get an accurate reading of the rooms temperature. If the intake vent is in another room or the unit cannot be
installed near the intake vent for any other reason, install it 1.5m above the floor on a wall where there is convection.
In order to get an accurate reading of the rooms temperature, install the signal receiver in a location
where it is not exposed directly to cold or hot air from the air discharge grille or to direct sunlight.
Since the receiver has a built-in light receptor to receive signals from the wireless remote controller, do
not mount it in a location where the signal may be blocked by a curtain, etc.

2500
*H=
or more 240 or more

If there is
no ceiling

200

Optimum air distribution is ensured.


The air passage is not blocked.
Condensate can drain properly.
The ceiling is strong enough to bear the weight of the indoor unit.
300
or more
A false ceiling does not seem to be at an incline.
Maintenance
Control box
Sufficient clearance for maintenance and servicing is ensured.
space
Piping between the indoor and outdoor units is within the allowable limits.
(Refer to the installation manual for the outdoor unit.)
The indoor unit, outdoor unit, power supply wiring and transmission wiring is at least
1 meter away from televisions and radios. This prevents image interference and noise
in electrical appliances. (Noise may be generated depending on the conditions under
20 or more
which the electric wave is generated, even if a one-meter allowance is maintained.)
Use suspension bolts to install the unit. Check whether or not the ceiling is strong enough to support the weight
Ceiling
of the unit. If there is a risk that the ceiling is not strong enough, reinforce the ceiling before installing the unit.
(Installation pitch is marked on the carton box for installation. Refer to it to check for points requiring reinforcing.)
(length : mm) Floor surface
Select the *H dimension such that a downward slope of at least 1/100 is ensured as indicated in DRAIN PIPING WORK.
The installation pitch is listed on the packing material, and should be checked when deciding whether to reinforce the location or not.
Air discharge grille:
Wooden or plastic grille is recommended
because condensation may occur
depending on humidity conditions.

CAUTION
If the signal receiver is not installed in a location where there is convection of air, it may be unable to get an accurate reading of the rooms temperature.

Wireless Remote Controller

Outdoor unit

Turn on all the fluorescent lamps in the room, if any, and find the site where remote
controller signals are properly received by the indoor unit (within 4 metres).

For outdoor unit installation, see the installation


manual supplied with the Multi outdoor unit.

Installation Manual

203

Indoor Units

EDAU12-722

PREPARATIONS BEFORE INSTALLATION


620

Relation of the unit to the suspension bolt positions.


Install the inspection opening on the control box side where
maintenance and inspection of the control box are easy. Install the
inspection opening also in the lower part of the unit.

500
(length : mm)

Suspension
bolt pitch

Air discharge

Air inlet
A

Make sure the range of the units external static pressure is not exceeded.
(See the technical documentation for the range of the external static pressure setting.)
Open the installation hole. (Pre-set ceilings)
Once the installation hole is opened in the ceiling where the unit is
to be installed, pass refrigerant piping, drain piping, transmission
wiring, and remote controller wiring (unneeded if using a wireless
remote controller) to the units piping and wiring holes.
See REFRIGERANT PIPING WORK, DRAIN PIPING WORK,
and WIRING.
After opening the ceiling hole, make sure ceiling is level if needed. It
might be necessary to reinforce the ceiling frame to prevent shaking.
Consult an architect or carpenter for details.

Control box

(Suspension bolt pitch)

Ceiling
SERVICE SPACE
620

450450
(Inspection
opening size)

Model
25 35 50 type
60 type

(length: mm)
B
A
900
940
1100
1140

Allow view
Inspection door
(Ceiling opening)

Ceiling slab

Install the suspension bolts.


(Use W3/8 to M10 suspension bolts.)
Use a hole-in-anchor, sunken insert, sunken anchor for existing
ceilings, and a sunken insert, sunken anchor or other part to be
procured in the field to reinforce the ceiling to bearing the weight of
the unit. (Refer to Fig.)

Anchor bolt
Long nut or turn-buckle
Suspension bolt
Indoor unit
NOTE: All the above parts are field supplied.

Mount chamber lid and air filter (accessory).


For bottom intake, replace the chamber lid in
the procedure listed in Fig.
(1) Remove the protection net. (8 locations)
Remove the chamber lid. (7 locations)
(2) Reattached the removed chamber lid in the
orientation shown in Fig. (7 locations)
Reattached the removed protection net in
the orientation shown in Fig. (8 locations)

(1)

Air inlet
Protection net

Chamber lid

Chamber lid
Air discharge

Air discharge
Protection net

(3) Attach sealing pad as shown in the figure below. (Stored in outlet vent)
(In order to take in the air inside the ceiling,
Sealing pad (Small)
and when not taking in air from outdoor air,
(accessory)
(3)
it is not necessary to stick.)
Attach the sealing pad (accessory) to the
plate metal sections which are not
covered by anti-sweat material.
Make sure there are no gaps between the
different pieces of sealing pad.
(4) Attach the hanger (right) insulation to the
right hanger. (Stored in outlet vent)
(See the below figure for the sticking base
line.)

(2)

Air inlet

Sealing pad (Small)


(accessory)
Air inlet

Air inlet
Sealing pad
(Large)
(accessory)

Air
discharge

Sealing pad
(Large)
(accessory)

Air
discharge

Anti-sweat material
included with the product

Anti-sweat material
included with the product

For rear intake type

For bottom intake type

Hanger bracket (right)

Hanger (right) insulation


line
se
ba
ing
k
Stic

Slit

(5) Attach the air filter (accessory) in the


manner shown in the diagram.

(5)

ARROW VIEW

In case of bottom side

In case of back side


Main unit

Force

Filter
Force

Attach the
filter to the
main unit
while
pushing
down on
the tabs.

When two indoor units are installed in one room, one of the two
wireless remote controllers can be easily set for another addresses.

PCB in the indoor unit


J4

Cut the jumper JA on PCB.

Wireless remote controller


Cut the jumper J4.

Wireless
remote
controller

J4
EXIST
CUT

204

ADDRESS
1
2

JA

ADDRESS

JB
JC

ADDRESS: JA
EXIST 1
CUT
2

Installation Manual

EDAU12-722

Indoor Units

INDOOR UNIT INSTALLATION


As for the parts to be used for installation work, be sure to use the provided accessories and specified parts designated by our company.
Install the indoor unit temporarily.
Attach the hanger bracket to the suspension bolt. Be sure to fix
it securely by using a nut and washer from the upper and lower
sides of the hanger bracket. (Refer to Fig.)

[ Securing the hanger bracket ]


Part to be procured in the field

[ PRECAUTION ]
Since the unit uses a plastic drain pan, prevent welding spatter and
other foreign substances from entering the outlet hole during installation.

[ How to secure washers ]

Washer for
hanging bracket
(accessory)
Hanger
bracket

Insert
below washer
Washer
fixing plate
(accessory)

Tighten
(double nut)

Adjust the height of the unit.


Check the unit is horizontally level.

CAUTION
Make sure the unit is installed level using a level or a plastic tube filled with water. In using a
plastic tube instead of a level, adjust the top surface of the unit to the surface of the water at
both ends of the plastic tube and adjust the unit horizontally. (One thing to watch out for in
particular is if it is installed so that the slope is not in the direction of the drain piping, as this
might cause leaking.)

Level
Vinyl tube

Tighten the upper nut.


Mounting the receiver.
Mount the receiver as shown below.

1 Press the receiver into the


mounting frame.

2 Mount the completed


assembly using two screws.

3 Press the decorative cover into


the mounting frame.

NOTE) Mount the Remote controller cord far enough away from strong electrical wires (such as distribution wires for electrical lights,
air conditioners, etc.) and from weak electrical wires (such as wires for telephones, intercoms, etc.).

For heat pump: If your feet feel cold when using the heating function, it is recommended
that the air discharge grille shown at below be attached.
45
(Adjustable angle)

OUTDOOR UNIT INSTALLATION


Install as described in the installation manual supplied with the Multi outdoor unit.

Installation Manual

205

Indoor Units

EDAU12-722

REFRIGERANT PIPING WORK

See the installation manual supplied with the Multi outdoor unit
for outdoor unit.

FLARING THE PIPE END

1. Cut the pipe end with a pipe cutter.


2. Remove burrs with the cut surface facing downward so that
the chips do not enter the pipe.
3. Put the flare nut on the pipe.
4. Flare the pipe.
5. Check that the flaring is properly made.

WARNING
Do not use mineral oil on flared part.
Prevent mineral oil from getting into the system as this
would reduce the lifetime of the units.
Never use piping which has been used for previous
installations. Only use parts which are delivered with the unit.
Do never install a drier to this R410A unit in order to guarantee
its lifetime.
The drying material may dissolve and damage the system.
Incomplete flaring may cause refrigerant gas leakage.

(Cut exactly at right angles.)

Remove burrs

Flaring
Set exactly at the position shown below.
Flare tool
Conventional flare tool
for R410A
A
Clutch-type Wing-nut type
Clutch-type
(Rigid-type) (Imperial-type)
Die

0 ~ 0.5mm

1.0 ~ 1.5mm

1.5 ~ 2.0mm

Check
The pipe end must
be evenly flared in a
perfect circle.

Flares inner surface


must be flaw-free.

Make sure that the


flare nut is fitted.

REFRIGERANT PIPING

1. To prevent gas leakage, apply refrigeration machine oil on


both inner and outer surfaces of the flare.
(Use refrigeration oil for R410A)
2. Align the centres of both flares and tighten the flare nuts 3 or 4
turns by hand. Then tighten them fully with the torque wrenches.
Use torque wrenches when tightening the flare nuts to
prevent damage to the flare nuts and escaping gas.

Flare nut tightening torque


Gas side
3/8 inch
1/2 inch
49.5~60.3N m
32.7~39.9N m
(333~407kgf cm)
(505~615kgf cm)

Liquid side
1/4 inch
14.2~17.2N m
(144~175kgf cm)

CAUTION
Overtightening may damage the flare and cause leaks.
Coat here with
refrigeration machine oil

Torque wrench
Liquid Piping Insulation Procedure
Piping insulation
material (main unit)

Spanner

Insulation for fitting


(attached)
Flare nut connection

Flare nut
Attach to base
Piping union

Turn seams up

Main unit
Clamp (attached)

Piping insulation material


(Field supply)

3. After the work is finished, make sure to check that there


is no gas leak.
4. After checking for gas leaks, be sure to insulate the pipe
connections.
Insulate using the insulation for fitting included with the
liquid and gas pipes. Besides, make sure the insulation for
fitting on the liquid and gas piping has its seams facing up.
(Tighten both edges with clamp.)
For the gas piping, wrap the medium sealing pad over the
insulation for fitting (flare nut part).

Liquid pipe

Gas pipe
Gas Piping Insulation Procedure
Piping insulation
material (main unit)
Attach to base

CAUTION
Be sure to insulate any field piping all the way to the piping
connection inside the unit. Any exposed piping may cause
condensation or burns if touched.

206

Main unit
Clamp
(attached)

Insulation for fitting


(attached)

Measure the length of the gas


pipe as you will have to cover
it with the sealing tape.

Flare nut connection


Turn seams up

Small sealing pad


(attached)
Main unit

Piping insulation material


(Field supply)

Wrap the sealing


tape around the
gas pipe.

Installation Manual

EDAU12-722

Indoor Units

Cautions on Pipe Handling


Protect the open end of the pipe against dust and
moisture.
(Tighten both edges with clamp.)
All pipe bends should be as gentle as possible.
Use a pipe bender for bending.
(Bending radius should be 30 to 40mm or larger.)

Wall

Be sure to
place a cap.
Rain

If no flare cap is
available, cover
the flare mouth
with tape to keep
dirt or water out.

Selection of Copper and Heat Insulation materials


When using commercial copper pipes and fittings, observe the following:
Insulation material: Polyethylene foam
Heat transfer rate: 0.041 to 0.052W/mK (0.035 to 0.045kcal/mhC)
Refrigerant gas pipes surface temperature reaches 110C max.
Choose heat insulation materials that will withstand this temperature.
Be sure to insulate both the gas and liquid piping and to provide insulation dimensions as below.
Gas side

Liquid side

25/35 class

50/60 class

O.D. 9.5mm

O.D. 12.7mm
Thickness 0.8mm

O.D. 6.4mm

Gas pipe thermal insulation


25/35 class

50/60 class

Liquid pipe
thermal insulation

I.D. 12-15mm

I.D. 14-16mm

I.D. 8-10mm

Thickness 10mm Min.

Also, when subject to high humidity, heat insulation of the refrigerant piping (the unit piping and
branch piping) must be further reinforced.
Reinforce the insulation when installing the unit near bathrooms, kitchens, and other similar locations.
Refer to the following:
30C, more than 75% RH: 20mm Min. in thickness
If the insulation is not sufficient, condensation may form on the surface of the insulation.
Use separate thermal insulation pipes for gas and liquid refrigerant pipes.

Inter-unit wiring
Gas pipe

Gas pipe
insulation
Finishing tape

Installation Manual

Liquid pipe

Liquid pipe
insulation
Drain hose

207

Indoor Units

EDAU12-722

DRAIN PIPING WORK


CAUTION
Make sure all water is out before making the duct connection.
Install the drain piping.
Drain pipe connection hole

Connect the drain pipe after removing the rubber cap and
insulation tubing attached to the connection hole.

Refrigerant piprs

To keep the drain tube from sagging, space hanging wires every 1 to 1.5m.
Use the drain hose and the metal clamp. Insert the drain hose
fully into the drain socket and firmly tighten the metal clamp with
the upper part of the tape on the hose end. Tighten the metal
clamp until the screw head is less than 4mm from the hose.
The two areas below should be insulated because
condensation may form there causing water to leak.
Drain piping passing indoors
Drain sockets
Referring the figure below, insulate the metal clamp and
drain hose using the included large sealing pad.
Clamp metal
(attached)

Make sure the drain works properly.


The diameter of the drain pipe should be greater than or
equal to the diameter of the connecting pipe
(vinyl tube; pipe size: 20mm; outer dimension: 26mm).
Keep the drain pipe short and sloping downwards at a
gradient of at least 1/100 to prevent air pockets from forming.

Tape

Drain hose

Large sealing pad


(attached)
Clamp metal
(attached)
4mm

PRECAUTION
Drain piping connections
Do not connect the drain piping directly to sewage pipes that
smell of ammonia. The ammonia in the sewage might enter the
indoor unit through the drain pipes and corrode the heat exchanger.
Do not twist or bend the drain hose, so that excessive force is not applied to it.
(This type of treatment may cause leaking.)
After piping work is finished, check drainage flows smoothly.
Gradually insert approximately 1L of water into the drain pan to
check drainage in the manner described below.

CAUTION
Water accumulating in the drain piping can cause the
drain to clog.

Gradually pour approximately 1L of


water from the outlet hole into the
drain pan to check drainage.
Check the drainage.

Air outlet
Portable pump

Bucket

Refrigerant
pipes
Drain outlet

INSTALLING THE DUCT


Connect the duct supplied in the field.
Air inlet side
Attach the duct and intake-side flange (field supply).
Connect the flange to the main unit with accessory screws
(in 20 or 24 positions).
Wrap the intake-side flange and duct connection area with
aluminum tape or something similar to prevent air escaping.

CAUTION

Outlet side
Connect the duct according to the inside of the outlet-side
flange.
Wrap the outlet-side flange and the duct connection area with
aluminum tape or something similar to prevent air escaping.

CAUTION

When attaching a duct to the intake side, be sure also to


attach an air filter inside the air passage on the intake side.
(Use an air filter whose dust collecting efficiency is at least
50% in a gravimetric technique.)
Flange
(Field supply)
Main unit

Connection screw
(accessory)

Flange

Be sure to insulate the duct to prevent condensation from


forming. (Material: glass wool or polyethylene foam, 25mm
thick)
Use electric insulation between the duct and the wall when
using metal ducts to pass metal laths of the net or fence
shape or metal plating into wooden buildings.

Insulation
material
(Field supply)

Aluminum tape
(Field supply)
Aluminum tape
(Field supply)
Air inlet side

208

Outlet side

Installation Manual

EDAU12-722

Indoor Units

WIRING

See the installation manual supplied with the Multi outdoor unit for outdoor unit.

How to connect wirings.


Wire only after removing the control box lid as shown in the
Fig.

[ Connecting electrical wiring ]


Terminal block (4P)

Control box lid

Power supply wiring


Earth wire

Power supply wiring


Earth wire
Wiring through hole

Indoor PCboard(ASSY)

Wiring Diagram
(Rear)

Remote controller wiring

(Control box side)

Power supply wiring


Earth wire

Wiring

Clamp (for fixing in place)


Clasp

(attached)

(Power supply side)

Clamp
(for fixing in place)
(attached)

Make sure to let a wire go through a wire penetration area.


After wiring, seal the wire and wire penetration area to
prevent moisture and small creatures from the outside.
Wrap the strong and weak electric lines with the sealing
material as shown in the figure below.
(Otherwise, moisture or small creatures such as insects from
the outside may cause short-circuit inside the control box.)
Attach securely so that there are no gaps.
Sealing material
(attached)

Wire

Outside
unit

Power supply wiring and Earth wire


Remove the control box lid.
Next, pull the wires into the unit through the wiring through hole
and connect to the power wiring terminal block (4P).

WARNING
Do not use tapped wires, stand wires, extensioncords, or
starbust connections, as they may cause overheating,
electrical shock, or fire.

Wiring
through hole

To outdoor unit

When wire length exceeds


10m, use 2.0-mm wires.

Inside
unit

[How to adhere it]

CAUTION

Indoor
unit

1
2
3

1.6mm or 2.0mm
H05VV

When clamping the wiring, use the included clamping


material as shown in the Fig. to prevent outside pressure
being exerted on the wiring connections and clamp firmly.
When doing the wiring, make sure the wiring is neat and
does not cause the control box lid to stick up, then close the
cover firmly. When attaching the control box lid, make sure
you do not pinch any wires.
Outside the machine, separate the weak wiring (remote
controller) and strong wiring (earth wire and power supply
wiring) at least 50mm so that they do not pass through the
same place together. Proximity may cause electrical
interference, malfunctions, and breakage.
[ PRECAUTION ]
See also the Electrical Wiring Diagram Nameplate when
wiring the unit for electrical power.

Installation Manual

209

Indoor Units

EDAU12-722

TRIAL OPERATION AND TESTING


Trial Operation and Testing
(1) Measure the supply voltage and make sure that it falls in the specified range.
(2) Trial operation should be carried out in either cooling or heating mode.

Trial operation from Remote Controller


(1) Press ON/OFF button to turn on the system.
(2) Simultaneously press center of TEMP button and MODE button.
(3) Press MODE button twice.
( will appear on the display to indicate that Trial Operation mode is selected.)
(4) Trial run mode terminates in approx. 30 minutes and switches into normal mode. To quit a trial operation, press ON/OFF button.
In cooling mode, select the lowest programmable temperature; in heating mode, select the highest programmable temperature.
Trial operation may be disabled in either mode depending on the room temperature.
Use the remote control for trial operation as described below.
After trial operation is complete, set the temperature to a normal level (26C to 28C in cooling mode, 20C to 24C in heating mode).
For protection, the system disables restart operation for 3 minutes after it is turned off.
(3) Carry out the test operation in accordance with the Operation Manual to ensure that all functions and parts, are working properly.
* The air conditioner requires a small amount of power in its standby mode. If the system is not to be used for some time after
installation, shut off the circuit breaker to eliminate unnecessary power consumption.
* If the circuit breaker trips to shut off the power to the air conditioner, the system will restore the original operation mode when
the circuit breaker is turned on again.

Test Items
Test Items
Indoor and outdoor units are installed properly on solid bases.
No refrigerant gas leaks.
Refrigerant gas and liquid pipes and indoor drain hose extension
are thermally insulated.
Draining line is properly installed.
System is properly earthed.
The specified wires are used for interconnecting wire connections.
Indoor or outdoor units air inlet or discharge has clear path of air.
Shut-off valves are opened.
Indoor unit properly receives remote controller commands.

Symptom
(diagnostic display on RC)

Check

Fall, vibration, noise


Incomplete cooling/heating function
Water leakage
Water leakage
Electrical leakage
Inoperative or burn damage
Incomplete cooling/heating function
Inoperative

3P141286-7H

210

Installation Manual

EDAU12-722

1.6

Indoor Units

Duct Connected Type CDXS 25/35 E

ACCESSORIES
Clamp metal

Insulation
for fitting

1 pc.

1 each

Sealing pad
Large and small
1 each

for gas pipe

Large

for liquid pipe

Small

Screws for
duct flanges

Air fillter

1 set

1 pc.

Drain hose

1 pc.

1 pc.

Washer for
hanging bracket Sealing material
8 pcs.

Washer
fixing plate

6 pcs.

1 set

Hanger (right)
insulation
Stored in
outlet vent

4 pcs.

Wireless
Remote controller
AAA
remote controller
holder
dry-cell batteries
1 pc.

2 pcs.

Clamp

1 pc.

1 set

Receiver kit
1 pc.

1 pc.

2 pcs.

Mounting
frame

Decorative
cover

Screws
M4 25

[ Other ]
Operation
manual
Installation
manual

24 pcs.

2 pcs.

CHOOSING A SITE
Before choosing the installation site, obtain user approval.

Indoor unit
CAUTION
When moving the unit during or after unpacking, make sure to lift it by holding its lifting lugs. Do not exert any pressure on other
parts, especially the refrigerant piping, drain piping and flange parts.
Wear protective gears (gloves and so on) when installing the unit.
If you think the humidity inside the ceiling might exceed 30C and RH80%, reinforce the insulation on the unit body.
Use glass wool or polyethylene foam as insulation so that the thickness is more than 10mm and fits inside the ceiling opening.

Select the signal receiver mounting location according to the following conditions:
Install the signal receiver, which has a built-in temperature sensor, near the intake vent where there is convection of air
and it can get an accurate reading of the rooms temperature. If the intake vent is in another room or the unit cannot be
installed near the intake vent for any other reason, install it 1.5m above the floor on a wall where there is convection.
In order to get an accurate reading of the rooms temperature, install the signal receiver in a location
where it is not exposed directly to cold or hot air from the air discharge grille or to direct sunlight.
Since the receiver has a built-in light receptor to receive signals from the wireless remote controller, do
not mount it in a location where the signal may be blocked by a curtain, etc.

2500
*H=
or more 240 or more

If there is
no ceiling

200

Optimum air distribution is ensured.


The air passage is not blocked.
Condensate can drain properly.
The ceiling is strong enough to bear the weight of the indoor unit.
300
or more
A false ceiling does not seem to be at an incline.
Maintenance
Control box
Sufficient clearance for maintenance and servicing is ensured.
space
Piping between the indoor and outdoor units is within the allowable limits.
(Refer to the installation manual for the outdoor unit.)
The indoor unit, outdoor unit, power supply wiring and transmission wiring is at least
1 meter away from televisions and radios. This prevents image interference and noise
in electrical appliances. (Noise may be generated depending on the conditions under
20 or more
which the electric wave is generated, even if a one-meter allowance is maintained.)
Use suspension bolts to install the unit. Check whether or not the ceiling is strong enough to support the weight
Ceiling
of the unit. If there is a risk that the ceiling is not strong enough, reinforce the ceiling before installing the unit.
(Installation pitch is marked on the carton box for installation. Refer to it to check for points requiring reinforcing.)
(length : mm) Floor surface
Select the *H dimension such that a downward slope of at least 1/100 is ensured as indicated in DRAIN PIPING WORK.
The installation pitch is listed on the packing material, and should be checked when deciding whether to reinforce the location or not.
Air discharge grille:
Wooden or plastic grille is recommended
because condensation may occur
depending on humidity conditions.

CAUTION
If the signal receiver is not installed in a location where there is convection of air, it may be unable to get an accurate reading of the rooms temperature.

Wireless Remote Controller

Outdoor unit

Turn on all the fluorescent lamps in the room, if any, and find the site where remote
controller signals are properly received by the indoor unit (within 4 metres).

For outdoor unit installation, see the installation


manual supplied with the Multi outdoor unit.

Installation Manual

211

Indoor Units

EDAU12-722

PREPARATIONS BEFORE INSTALLATION


620

Relation of the unit to the suspension bolt positions.


Install the inspection opening on the control box side where
maintenance and inspection of the control box are easy.
Install the inspection opening also in the lower part of the unit.

(length : mm)

Suspension
bolt pitch

Air discharge

Air inlet

Open the installation hole. (Pre-set ceilings)


Once the installation hole is opened in the ceiling where the unit is
to be installed, pass refrigerant piping, drain piping, transmission
wiring, and remote controller wiring (unneeded if using a wireless
remote controller) to the units piping and wiring holes.
See REFRIGERANT PIPING WORK, DRAIN PIPING WORK,
and WIRING.
After opening the ceiling hole, make sure ceiling is level if needed. It
might be necessary to reinforce the ceiling frame to prevent shaking.
Consult an architect or carpenter for details.

Control box

(Suspension bolt pitch)

Ceiling

SERVICE SPACE
620

450450

Make sure the range of the units external static pressure is not exceeded.
(See the technical documentation for the range of the external static pressure setting.)

500

(Inspection
opening size)

(length: mm)
A
B
700
740

Model
25 35

Allow view
Inspection door
(Ceiling opening)

Ceiling slab

Install the suspension bolts.


(Use W3/8 to M10 suspension bolts.)
Use a hole-in-anchor, sunken insert, sunken anchor for existing
ceilings, and a sunken insert, sunken anchor or other part to be
procured in the field to reinforce the ceiling to bearing the weight of
the unit. (Refer to Fig.)

Anchor bolt
Long nut or turn-buckle
Suspension bolt
Indoor unit
NOTE: All the above parts are field supplied.

Mount chamber lid and air filter (accessory).


For bottom intake, replace the chamber lid and
the protection net in the procedure listed in Fig.
(1) Remove the protection net. (6 locations)
Remove the chamber lid. (7 locations)
(2) Reattach the removed chamber lid in the
orientation shown in Fig.(7 locations)
Reattach the removed protection net in the
orientation shown in Fig. (6 locations)
Refer to Fig.for the direction of the
protection net.

(3) Attach the hanger (right) insulation to the


right hanger. (Stored in outlet vent)
(See the below figure for the sticking base
line.)

Protection net

(1)

(2)

Air inlet

Chamber lid
Chamber lid
Air discharge

Protection net
Air discharge

Air inlet

(3)

Hanger bracket (right)

Hanger (right) insulation

Slit
S

(4) Attach the air filter (accessory) in the


manner shown in the diagram.

se

ing
tick

(4) In case of bottom side

ARROW VIEW

In case of back side


Main unit

Force

Filter
Force

212

lin

ba

Attach the
filter to the
main unit
while
pushing
down on
the bends.

Installation Manual

EDAU12-722

Indoor Units

When two indoor units are installed in one room, one of the two
wireless remote controllers can be easily set for another addresses.

PCB in the indoor unit


J4

Cut the jumper JA on PCB.

Wireless remote controller


Cut the jumper J4.

Wireless
remote
controller

J4
EXIST
CUT

ADDRESS
1
2

ADDRESS: JA
EXIST 1
CUT
2

JA

ADDRESS

JB
JC

INDOOR UNIT INSTALLATION


As for the parts to be used for installation work, be sure to use the provided accessories and specified parts designated by our company.
Install the indoor unit temporarily.
Attach the hanger bracket to the suspension bolt. Be sure to fix
it securely by using a nut and washer from the upper and lower
sides of the hanger bracket. (Refer to Fig.)

[ Securing the hanger bracket ]


Part to be procured in the field

[ PRECAUTION ]
Since the unit uses a plastic drain pan, prevent welding spatter and
other foreign substances from entering the outlet hole during installation.

[ How to secure washers ]

Washer for
hanging bracket
(accessory)
Hanger
bracket

Insert
below washer
Washer
fixing plate
(accessory)

Tighten
(double nut)

Adjust the height of the unit.


Check the unit is horizontally level.

CAUTION
Make sure the unit is installed level using a level or a plastic tube filled with water.In using a plastic
tube instead of a level ,adjust the top surface of the unit to the surface of the water at both ends of
the plastic tube and adjust the unit horizontally.(One thing to watch out for in particular is if it is
installed so that the slope is not in the direction of the drain piping,as this might cause leaking.)
Level

Tighten the upper nut.

Vinyl tube

Mounting the receiver.


Mount the receiver as shown below.

1 Press the receiver into the


mounting frame.

2 Mount the completed


assembly using two screws.

3 Press the decorative cover into


the mounting frame.

NOTE) Mount the Remote controller cord far enough away from strong electrical wires (such as distribution wires for electrical lights,
air conditioners, etc.) and from weak electrical wires (such as wires for telephones, intercoms, etc.).

For heat pump: If your feet feel cold when using the heating function, it is recommended
that the air discharge grille shown at below be attached.
45
(Adjustable angle)

OUTDOOR UNIT INSTALLATION


Install as described in the installation manual supplied with the Multi outdoor unit.

Installation Manual

213

Indoor Units

EDAU12-722

REFRIGERANT PIPING WORK

See the installation manual supplied with the Multi outdoor unit
for outdoor unit.

FLARING THE PIPE END

1. Cut the pipe end with a pipe cutter.


2. Remove burrs with the cut surface facing downward so that
the chips do not enter the pipe.
3. Put the flare nut on the pipe.
4. Flare the pipe.
5. Check that the flaring is properly made.

(Cut exactly at right angles.)

Remove burrs

Flaring
Set exactly at the position shown below.
Flare tool
Conventional flare tool
for R410A
A

WARNING
Do not use mineral oil on flared part.
Prevent mineral oil from getting into the system as this
would reduce the lifetime of the units.
Never use piping which has been used for previous
installations. Only use parts which are delivered with the unit.
Do never install a drier to this R410A unit in order to guarantee
its lifetime.
The drying material may dissolve and damage the system.
Incomplete flaring may cause refrigerant gas leakage.

Clutch-type

Clutch-type
(Rigid-type)

Wing-nut type
(Imperial-type)

0-0.5mm

1.0-1.5mm

1.5-2.0mm

Die

Check
The pipe end must
be evenly flared in a
perfect circle.

Flares inner surface


must be flaw-free.

Make sure that the


flare nut is fitted.

REFRIGERANT PIPING

1. To prevent gas leakage, apply refrigeration machine oil on


both inner and outer surfaces of the flare.
(Use refrigeration oil for R410A)
2. Align the centres of both flares and tighten the flare nuts 3 or 4
turns by hand. Then tighten them fully with the torque wrenches.
Use torque wrenches when tightening the flare nuts to
prevent damage to the flare nuts and escaping gas.

Flare nut tightening torque


Gas side
Liquid side
3/8 inch
1/4 inch
32.7-39.9Nm
14.2-17.2Nm
(333-407kgfcm)
(144-175kgfcm)

CAUTION
Overtightening may damage the flare and cause leaks.
Coat here with
refrigeration machine oil

Torque wrench
Liquid Piping Insulation Procedure
Piping insulation
material (main unit)

Spanner

Insulation for fitting


(attached)
Flare nut connection

Flare nut
Attach to base
Piping union

Turn seams up

Main unit
Clamp (attached)

Piping insulation material


(Field supply)

3. After the work is finished, make sure to check that there


is no gas leak.
4. After checking for gas leaks, be sure to insulate the pipe
connections.
Insulate using the insulation for fitting included with the
liquid and gas pipes. Besides, make sure the insulation for
fitting on the liquid and gas piping has its seams facing up.
(Tighten both edges with clamp.)
For the gas piping, wrap the medium sealing pad over the
insulation for fitting (flare nut part).

Liquid pipe

Gas pipe
Gas Piping Insulation Procedure
Piping insulation
material (main unit)
Attach to base

CAUTION
Be sure to insulate any field piping all the way to the piping
connection inside the unit. Any exposed piping may cause
condensation or burns if touched.

214

Main unit
Clamp
(attached)

Insulation for fitting


(attached)

Measure the length of the gas


pipe as you will have to cover
it with the sealing tape.

Flare nut connection


Turn seams up

Small sealing pad


(attached)
Main unit

Piping insulation material


(Field supply)

Wrap the sealing


tape around the
gas pipe.

Installation Manual

EDAU12-722

Indoor Units

Cautions on Pipe Handling


Protect the open end of the pipe against dust and
moisture.
(Tighten both edges with clamp.)
All pipe bends should be as gentle as possible.
Use a pipe bender for bending.
(Bending radius should be 30 to 40mm or larger.)

Wall

Be sure to
place a cap.
Rain

If no flare cap is
available, cover
the flare mouth
with tape to keep
dirt or water out.

Selection of Copper and Heat Insulation materials


When using commercial copper pipes and fittings, observe the following:
Insulation material: Polyethylene foam
Heat transfer rate: 0.041 to 0.052W/mK (0.035 to 0.045kcal/mhC)
Refrigerant gas pipes surface temperature reaches 110C max.
Choose heat insulation materials that will withstand this temperature.
Be sure to insulate both the gas and liquid piping and to provide insulation dimensions as below.
Gas side

Liquid side

25/35 class
O.D. 9.5mm

O.D. 6.4mm
Thickness 0.8mm

Gas pipe thermal insulation


25/35 class

Liquid pipe
thermal insulation

I.D. 12-15mm

I.D. 8-10mm

Thickness 10mm Min.

Also, when subject to high humidity, heat insulation of the refrigerant piping (the unit piping and
branch piping) must be further reinforced.
Reinforce the insulation when installing the unit near bathrooms, kitchens, and other similar locations.
Refer to the following:
30C, more than 75% RH: 20mm Min. in thickness
If the insulation is not sufficient, condensation may form on the surface of the insulation.
Use separate thermal insulation pipes for gas and liquid refrigerant pipes.

Inter-unit wiring
Gas pipe

Liquid pipe

Gas pipe
insulation

Liquid pipe
insulation

Finishing tape

Drain hose

DRAIN PIPING WORK


CAUTION
Make sure all water is out before making the duct connection.
Install the drain piping.
Drain pipe connection hole

Refrigerant piprs

Connect the drain pipe after removing the rubber cap and
insulation tubing attached to the connection hole.

Make sure the drain works properly.


The diameter of the drain pipe should be greater than or
equal to the diameter of the connecting pipe
(vinyl tube; pipe size: 20mm;
outer dimension: 26mm).
Keep the drain pipe short and sloping downwards at a
gradient of at least 1/100 to prevent air pockets from forming.

To keep the drain tube from sagging, space hanging wires every 1 to 1.5m.
Use the drain hose and the metal clamp. Insert the drain hose
fully into the drain socket and firmly tighten the metal clamp with
the upper part of the tape on the hose end. Tighten the metal
clamp until the screw head is less than 4mm from the hose.
The two areas below should be insulated because
condensation may form there causing water to leak.
Drain piping passing indoors
Drain sockets
Referring the figure below, insulate the metal clamp and
drain hose using the included large sealing pad.
Clamp metal
(attached)

Tape

Drain hose

Large sealing pad


(attached)
Clamp metal
(attached)
4mm

PRECAUTION
Drain piping connections
Do not connect the drain piping directly to sewage pipes that
smell of ammonia. The ammonia in the sewage might enter the
indoor unit through the drain pipes and corrode the heat exchanger.
Do not twist or bend the drain hose, so that excessive force is not applied to it.
(This type of treatment may cause leaking.)
After piping work is finished, check drainage flows smoothly.
Gradually insert approximately 1L of water into the drain pan to
check drainage in the manner described below.

CAUTION
Water accumulating in the drain piping can cause the
drain to clog.

Gradually pour approximately 1L of


water from the outlet hole into the
drain pan to check drainage.
Check the drainage.

Air outlet
Portable pump

Bucket

Refrigerant
pipes
Drain outlet

Installation Manual

215

Indoor Units

EDAU12-722

INSTALLING THE DUCT


Connect the duct supplied in the field.
Air inlet side
Attach the duct and intake-side flange (field supply).
Connect the flange to the main unit with accessory screws
(in 16 positions).
Wrap the intake-side flange and duct connection area with
aluminum tape or something similar to prevent air escaping.

CAUTION

Outlet side
Connect the duct according to the inside of the outlet-side
flange.
Wrap the outlet-side flange and the duct connection area with
aluminum tape or something similar to prevent air escaping.

CAUTION

When attaching a duct to the intake side, be sure also to


attach an air filter inside the air passage on the intake side.
(Use an air filter whose dust collecting efficiency is at least
50% in a gravimetric technique.)
Flange
(Field supply)
Main unit

Connection screw
(accessory)

Flange

Be sure to insulate the duct to prevent condensation from


forming. (Material: glass wool or polyethylene foam, 25mm
thick)
Use electric insulation between the duct and the wall when
using metal ducts to pass metal laths of the net or fence
shape or metal plating into wooden buildings.

Insulation
material
(Field supply)

Aluminum tape
(Field supply)
Aluminum tape
(Field supply)
Air inlet side

216

Outlet side

Installation Manual

EDAU12-722

Indoor Units

WIRING

See the installation manual supplied with the Multi outdoor unit for outdoor unit.

How to connect wirings.


Wire only after removing the control box lid as shown in the
Fig.

[ Connecting electrical wiring ]


Terminal block (4P)

Control box lid

Power supply wiring


Earth wire

Power supply wiring


Earth wire
Wiring through hole

Indoor PCboard(ASSY)

Wiring Diagram
(Rear)

Remote controller wiring

(Control box side)

Power supply wiring


Earth wire

Wiring

Clamp (for fixing in place)


Clasp

(attached)

(Power supply side)

Clamp
(for fixing in place)
(attached)

Make sure to let a wire go through a wire penetration area.


After wiring, seal the wire and wire penetration area to
prevent moisture and small creatures from the outside.
Wrap the strong and weak electric lines with the sealing
material as shown in the figure below.
(Otherwise, moisture or small creatures such as insects from
the outside may cause short-circuit inside the control box.)
Attach securely so that there are no gaps.
Sealing material
(attached)

Wire

Outside
unit

Power supply wiring and Earth wire


Remove the control box lid.
Next, pull the wires into the unit through the wiring through hole
and connect to the power wiring terminal block (4P).

WARNING
Do not use tapped wires, stand wires, extensioncords, or
starbust connections, as they may cause overheating,
electrical shock, or fire.

Wiring
through hole

To outdoor unit

When wire length exceeds


10m, use 2.0-mm wires.

Inside
unit

[How to adhere it]

CAUTION

Indoor
unit

1
2
3

1.6mm or 2.0mm
H05VV

When clamping the wiring, use the included clamping


material as shown in the Fig. to prevent outside pressure
being exerted on the wiring connections and clamp firmly.
When doing the wiring, make sure the wiring is neat and
does not cause the control box lid to stick up, then close the
cover firmly. When attaching the control box lid, make sure
you do not pinch any wires.
Outside the machine, separate the weak wiring (remote
controller) and strong wiring (earth wire and power supply
wiring) at least 50mm so that they do not pass through the
same place together. Proximity may cause electrical
interference, malfunctions, and breakage.
[ PRECAUTION ]
See also the Electrical Wiring Diagram Nameplate when
wiring the unit for electrical power.

Installation Manual

217

Indoor Units

EDAU12-722

TRIAL OPERATION AND TESTING


Trial Operation and Testing
(1) Measure the supply voltage and make sure that it falls in the specified range.
(2) Trial operation should be carried out in either cooling or heating mode.

Trial operation from Remote Controller


(1) Press ON/OFF button to turn on the system.
(2) Simultaneously press center of TEMP button and MODE button.
(3) Press MODE button twice.
( will appear on the display to indicate that Trial Operation mode is selected.)
(4) Trial run mode terminates in approx. 30 minutes and switches into normal mode. To quit a trial operation, press ON/OFF button.
In cooling mode, select the lowest programmable temperature; in heating mode, select the highest programmable temperature.
Trial operation may be disabled in either mode depending on the room temperature.
Use the remote control for trial operation as described below.
After trial operation is complete, set the temperature to a normal level (26C to 28C in cooling mode, 20C to 24C in heating mode).
For protection, the system disables restart operation for 3 minutes after it is turned off.
(3) Carry out the test operation in accordance with the Operation Manual to ensure that all functions and parts, are working properly.
* The air conditioner requires a small amount of power in its standby mode. If the system is not to be used for some time after
installation, shut off the circuit breaker to eliminate unnecessary power consumption.
* If the circuit breaker trips to shut off the power to the air conditioner, the system will restore the original operation mode when
the circuit breaker is turned on again.

Test Items
Test Items
Indoor and outdoor units are installed properly on solid bases.
No refrigerant gas leaks.
Refrigerant gas and liquid pipes and indoor drain hose extension
are thermally insulated.
Draining line is properly installed.
System is properly earthed.
The specified wires are used for interconnecting wire connections.
Indoor or outdoor units air inlet or discharge has clear path of air.
Shut-off valves are opened.
Indoor unit properly receives remote controller commands.

Symptom
(diagnostic display on RC)

Check

Fall, vibration, noise


Incomplete cooling/heating function
Water leakage
Water leakage
Electrical leakage
Inoperative or burn damage
Incomplete cooling/heating function
Inoperative

3P141286-6D

218

Installation Manual

EDAU12-722

1.7

Indoor Units

Floor / Ceiling Suspended Dual Type FLXS 25/35/50/60 B

ACCESSORIES
A Mounting plate
Mounting plate fixing screws
B
M4 X 25L

1
10

Heat insulation tube


N (Refrigerant pipe)
Heat insulation tube
P (Extension auxiliary pipe)

Q Binding bands

G AAA dry-cell batteries

H Photocatalytic deodorizing filter

C Air purifying filter

J Side covers

D Wireless remote controller

K Operation manual

E Remote controller holder

L Installation manuals

Fixing screws for remote controller


F holder M3 X 20L

M Extension auxiliary pipe

2The extension auxiliary pipe M P is not included for FLXS25, FLXS35.

CHOOSING A SITE
2Before choosing the installation site, obtain user approval.
Indoor unit
The indoor unit should be sited in a place where:
2 the restrictions on installation specified in the indoor unit installation
drawings are met,
2 both air intake and exhaust have clear paths met,
2 the unit is not in the path of direct sunlight,
2 the unit is away from the source of heat or steam,
2 there is no source of machine oil vapour (this may shorten indoor unit
life),
2 cool air is circulated throughout the room,
2 the unit is away from electronic ignition type fluorescent lamps (inverter
or rapid start type) as they may shorten the remote control range,
2 the unit is at least 1 metre away from any television or radio set (unit
may cause interference with the picture or sound).

Wireless Remote Controller


2Turn on all the fluorescent lamps in the
room, if any, and find the site where remote
control signals are properly received by the
indoor unit (within 7 metres).

BEFORE INSTALLING THE INDOOR UNIT


2Perform the following before
installing the indoor unit.
1 Open the air inlet grille and
the screw cover, and
remove the 7 screws.
2 Release the claws in the 3
places indicated.
3 Release the center hook and
remove the front panel.
4 Release the claws in the 2
places indicated and remove
the electric component
cover.

Screw cover
2 Claw
3

Electric
component
cover

ON
OFF

Claw
Front panel
Drain pan hook

1
2

Drain pan hook


Front panel hook
* Move the front panel in the
direction of the arrow
to
remove it from the drain pan
hook.

Air inlet grille


Front panel
To release the
center hook

INSTALLATION TIPS
How to the different addresses.
2When two indoor units installed in one room, the two wireless remote controllers can be set for different addresses.

SW2

(Refer to the BEFORE INSTALLING THE INDOOR UNIT .)


2Cut the jumper JA on PCB.
Wireless remote controller 2Cut the jumper J4

CEILING

FLOOR

PCB in the indoor unit

2Remove the electric component cover.


Wireless
remote
controller

J4

ADDRESS JA
EXIST
1
2
CUT

J4
ADDRESS
EXIST
1
2

In case of Ceiling suspended use.


CUT
2Slide the switch(SW2)to CEILING in case of installing on the ceiling.

Installation Manual

219

Indoor Units

EDAU12-722

INDOOR/OUTDOOR UNIT INSTALLATION DRAWINGS

There should be no space


between ceiling and the unit.

Space for installation work


Min. (200 mm)

Space for installation work


Min. (200 mm)
Air filters

50 mm or more
from walls

A Mounting plate

The mounting plate


should be installed on
a wall which can
support the weight of
the indoor unit.

B M4 X 25L
H Photocatalytic deodorizing filter or
C Air purifying filter

Space for
installation
work Min.
(200 mm)

ON
OFF

50 mm or more
from floor

D Wireless
remote controller

F
(M3 X 20L)

220

Cut thermal insulation pipe


to an appropriate length and
wrap it with tape, making
sure that no gap is left in the
insulation pipes cut line.

Space for
installation
work Min.
(200 mm)

Caulk pipe
hole gap
with putty.

Wrap the
insulation pipe
with the finishing
tape from bottom
to top.

Before screwing the remote


controller holder to the wall,
make sure that control signals are
properly received by indoor unit.

E
Remote
controller
holder

Installation Manual

EDAU12-722

Indoor Units

1
More than 170

INDOOR/OUTDOOR UNIT INSTALLATION DRAWINGS


Ceiling mounting
Rear side piping hole 65 mm
Local drain pipe

55
Ceiling

40

Ceiling
Wall

Rear side drain hose hole 40 mm

1 Determine the position of the


feed-through hole so that the
local piping is placed in a
downward sloping direction.

1,050
980

40

138

490

230

22
40~45

Right side
piping hole
65 mm

35

40

50

Drain hose

Wall

With a Multi indoor unit,


install as described in the
installation manual supplied
with the Multi outdoor unit.

Top side piping hole 65 mm

55

Wall mounting

55
Wall

40

40

Wall

Under side piping hole 80 mm

35

1,050

Floor

800

Right side piping hole 80 mm


Liquid pipe

102

40

97
30

Drain pipe

255

48

490

Wall

162

Gas pipe

26
Floor

150

Floor

Rear side piping hole 80 mm

55

Connection position

Installation Manual

221

Indoor Units

EDAU12-722

INDOOR UNIT
CEILING MOUNTING

INSTALLING THE SUSPENSION BOLT

2Install the suspension bolt so that it can support the indoor unit; adjust distance to ceiling before
installation.

40 ~ 45

25 ~ 30

Ceiling
Suspension
bolt
Spring
washer

Nut (M10)

Washer
Nut (M10)

Spring
washer

Suspension bolt
(M10)

J Side cover

Washer
M10 nut

2Mount the indoor unit according to the


installation drawings and tighten it
securely with M10 nut. (4 places)

Electric component cover


(2 claws)

J Side cover
(6 claws)

2After mounting the indoor unit on the


ceiling, install each part as shown in the
diagram on the right.

Front grille

Incline condition for installation


less than 1

less than 1

INSTALLING INDOOR UNIT

(1) Connect the extension auxiliary pipe


Upper right-side piping
( M , supplied) to the local piping. (See WALL
MOUNTING 1. INSTALLATION) (Applies to
both ceiling mounting and wall mounting units.)
(2) Prepare the local piping at the connection Right-side
piping
point for the drain pipe, as shown in the
Cut away here
Right-back piping
installation drawings.
Drain hose
for right-side
Note:
Be sure to place the drain hose as shown in the
diagram on the right, in a downward sloping
direction.

piping
Bottom frame cover
Cut away here
for right-back
piping
Note:
For upper right-side piping,
remove the bottom frame
cover before installing the
indoor unit.

(3) Connect the drain hose to the local drain pipe.


Position the interconnecting wire in the same
direction as the piping.
Feed-through portion of drain hose
For determining the position of the drain
hose, perform the following procedures.

Bottom frame

Bottom
frame claw
Panel

Drain hose

1 Cut out with


a nipper.

222

2 Cut out the drain


hose portion.

3 Screw it to the 4 After determining the position of the drain hose,


hook the panel to the bottom frame claws.
bottom frame.

Installation Manual

EDAU12-722

Indoor Units

INDOOR UNIT
WALL MOUNTING

INSTALLATION

2Install the indoor unit on the wall according to the installation drawings.
(1) Hang the indoor unit on the hooks of A mounting plate. (2 places)
(2) Fix the three holes in the lower portion of the indoor unit with B M4 x 25L screws.

3
A Mounting plate
J Side cover
(6 claws)

J Side cover
B M4 x 25L

Indoor unit
hook portion

Electric component cover


(2 claws)
Front grille

A Mounting plate

Condition for installation


less than 1

2 Work should be performed to match the (2)


direction of the piping, as the extension
auxiliary pipe
( M , supplied) and installation methods vary
depending on the direction the piping is
brought out.
(1) Select the extension auxiliary pipe in accordance
with the direction of the piping. (This should be
done without the included piping for wall-mounted
right-back piping and ceiling-mounted upper rightside piping.)
(2) Attach the heat insulation tube P to the extension
auxiliary pipe. (Make sure there are no gaps.)
(3) Attach the extension auxiliary pipe to the product.

(3)
Bottomright piping

Right side
piping

INSTALLING INDOOR UNIT


Note:

(1) Connect the extension auxiliary pipe


Remove the bottom frame cover for right-back
piping before installing the indoor unit.
( M , supplied) to the local piping.
(Applies to both ceiling mounting and
wall mounting units.)
(2) Prepare the local piping at the
connection point for the drain pipe, as Right-side piping
shown in the installation drawings.
Cut away here for
right-side piping
(3) Connect the drain hose to the local
Cut away here
drain pipe.
Right-back piping
for bottom-right
Position the interconnecting wire in the
piping
Bottom-right piping
same direction as the piping.

Installation Manual

223

Indoor Units

EDAU12-722

INDOOR UNIT
COMMONALITY BETWEEN CEILING MOUNTING AND WALL MOUNTING

WIRING

With a Multi indoor unit , install as


described in the installation manual
supplied with the Multi outdoor unit.

Remote control
cable(option)
Terminal blocks

Secure the wires so that


the structure does not rise.
S21 Fix securely so that

external force is not directly


(1) Strip wire ends (15 mm).
applied to the terminals.
(2) Match wire colours with terminal numbers on
indoor and outdoor units' terminal blocks and
firmly screw wires to the corresponding
Use
terminals.
designated
(3) Connect the earth wires to the corresponding
wire to
connect it
Earth wire
terminals.
securely.
(4) Pull wires to make sure that they are securely
Electric component
latched up, then retain wires with wire retainer. box
Wire clamp
(5) In case of connecting to an adapter system.
Run the remote control cable and attach the S21 connector as the illustration on the right.
(6) Shape the wires so that the service lid fits securely, then close service lid.

Warning
To outdoor unit
When wire length exceeds
10 m, use 2.0-mm wires.

3
Indoor 2
1
unit

H05VV

1) Do not use tapped wires,stand wires, extensioncords, or


starbust connections, as they may cause overheating,
electrical shock,or fire.
2) Do not use locally purchased electrical parts inside the
product. (Do not branch the power for the drain pump, etc.,
from the terminal block.) Doing so may cause electric
shock or fire.

INSULATION OF REFRIGERANT PIPES

After checking for refrigerant leaks


2 Joints in liquid pipe and the gas pipe

must be insulated with N heat


insulation tube attached with Q binding
bands.

Q Binding band

* Cut N heat insulation tube to appropriate


length.

N Heat insulation tube

DRAIN PIPING

2 Connect the drain hose, as described below.

2 Pour water into the drain pan from

the right side to check that water


flows smoothly from the drain hose.

Drain hose must


slope downward.

Allow no trap to
form in the piping.

Do not allow end of


hose to touch water.

Ceiling mounting

Wall mounting

2 When drain hose

requires extension,
obtain an extension
hose commercially
available.
After connecting the
local drain hose, tape
unit
the slits of the heat Indoor
drain hose
Tape here
insulation tube.
(Field supply)

Remove this socket for Wall mounting .

224

Ceiling mounting

Be sure to
attach this
part cut
from the
panel.

Extension
drain hose
(Field supply)

Heat insulation tube


(More than 10 mm:
Field supply)

Wall mounting

Installation Manual

EDAU12-722

Indoor Units

REFRIGERANT PIPING WORK

FLARING THE PIPE END

1. Cut the pipe end with a pipe cutter.


2. Remove burrs with the cut surface facing downward
so that the chips do not enter the pipe.
3. Put the flare nut on the pipe.
4. Flare the pipe.
5. Check that the flaring is properly made.

(Cut exactly at
right angles.)

Remove burrs

Flaring
Set exactly at the position shown below.
A

Die

Flare tool for R410A

Conventional flare tool

Clutch-type

Clutch-type (Rigid-type) Wing-nut type (Imperial-type)

0 ~ 0.5 mm

1.5 ~ 2.0 mm

1.0 ~ 1.5 mm

Warning
1) Do not use mineral oil on flared part.
2) Prevent mineral oil from getting into the system as this would reduce the lifetime of the units.
3) Never use piping which has been used for previous installations. Only use parts which are
delivered with the unit.
4) Do never install a drier to this R410A unit in order to guarantee its lifetime.
5) The drying material may dissolve and damage the system.
6) Incomplete flaring may cause refrigerant gas leakage.

Check
Flares inner
surface must
be flaw-free.

The pipe end must


be evenly flared in
a perfect circle.
Make sure that the
flare nut is fitted.

REFRIGERANT PIPING

1) Align the centres of both flares and tighten the flare nuts
3 or 4 turns by hand. Then tighten them fully with the
torque wrenches.
2 Use torque wrenches when tightening the flare nuts to
prevent damage to the flare nuts and escaping gas.
Torque wrench

Flare nut tightening torque


Gas side

Liquid side

3/8 inch

1/2 inch

1/4 inch

32.7-39.9N m

49.5-60.3N m

14.2-17.2N m

(333-407kgf cm)

(505-615kgf cm)

(144-175kgf cm)

Valve cap tightening torque


Coat here with refrigeration machine oil

Gas side

Spanner

Piping union
Flare nut

Liquid side

3/8 inch

1/2 inch

1/4 inch

21.6-27.4N m

26.5-32.3N m

21.6-27.4N m

(220-280kgf cm)

(270-330kgf cm)

(220-280kgf cm)

2) To prevent gas leakage, apply refrigeration machine oil on both inner and outer surfaces of the flare. (Use
refrigeration oil for R410A)
Cautions on Pipe Handling
1) Protect the open end of the pipe against dust and moisture.
2) All pipe bends should be as gentle as possible. Use a pipe bender
for bending.
(Bending radius should be 30 to 40 mm or larger.)

Wall

Be sure to
place a cap.
Rain

If no flare cap is
available, cover
the flare mouth
with tape to keep
dirt or water out.

Selection of Copper and Heat Insulation materials


When using commercial copper pipes and fittings, observe the following:
1) Insulation material: Polyethylene foam
Heat transfer rate: 0.041 to 0.052kW/mK (0.035 to 0.045 kcal/mhC)
Refrigerant gas pipe's surface temperature reaches 110C max.
Choose heat insulation materials that will withstand this temperature.
2) Be sure to insulate both the gas and liquid piping and to provide insulation dimensions as below.
Gas side
25/35 class
50/60 class
O.D. 9.5mm
O.D. 12.7mm
Thickness 0.8 mm

Liquid side
25/35/50/60 class
O.D. 6.4 mm
Thickness 0.8 mm

Gas pipe thermal insulation


Liquid pipe thermal insulation
25/35 class
50/60 class
25/35/50/60 class
I.D. 12 15 mm I.D. 14 16 mm
I.D. 8 10 mm
Thickness 10 mm Min.

Inter-unit wiring
Gas pipe

Gas pipe
insulation

Liquid pipe

Liquid pipe
insulation
Finishing tape

Drain hose

3) Use separate thermal insulation pipes for gas and liquid refrigerant pipes.

Installation Manual

225

Indoor Units

EDAU12-722

TRIAL OPERATION AND TESTING


Trial Operation and Testing
(1) Measure the supply voltage and make sure that it falls in the specified range.
(2) Trial operation should be carried out in either cooling or heating mode.
Trial operation from Remote Controller
(1) Press ON/OFF button to turn on the system.
(2) Simultaneously press center of TEMP button and MODE button.
(3) Press MODE button twice.
(" " will appear on the display to indicate that Trial Operation mode is selected.)
(4) Trial run mode terminates in approx. 30 minutes and switches into normal mode. To quit a trial operation,
press ON/OFF button.
In cooling mode, select the lowest programmable temperature; in heating mode, select the highest programmable
temperature.
Trial operation may be disabled in either mode depending on the room temperature.
Use the remote control trial operation as described below.
After trial operation is complete, set the temperature to a normal level
(26C to 28C in cooling mode, 20C to 24C in heating mode).
For protection, the system disables restart operation for 3 minutes after it is turned off.
(3) Carry out the test operation in accordance with the Operation Manual to ensure that all functions and parts, such as
louver movement, are working properly.
The air conditioner requires a small amount of power in its standby mode. If the system is not to be used for some
* time after installation, shut off the circuit breaker to eliminate unnecessary power consumption.
the circuit breaker trips to shut off the power to the air conditioner, the system will restore the original operation
* Ifmode
when the circuit breaker is opened again.
Test Items
Test Items

Symptom
(diagnostic display on RC)

Indoor and outdoor units are installed properly on solid bases.

Fall, vibration, noise

No refrigerant gas leaks.

Incomplete cooling/heating function

Refrigerant gas and liquid pipes and indoor drain hose


extension are thermally insulated.

Water leakage

Draining line is properly installed.

Water leakage

System is properly earthed.

Electrical leakage

The specified wires are used for interconnecting wire


connections.

Inoperative or burn damage

Indoor or outdoor unit's air intake or exhaust has clear path of air.
Shut-off valves are opened.

Incomplete cooling/heating function

Indoor unit properly receives remote control commands.

Inoperative

Check

3P141286-3

226

Installation Manual

EDAU12-722

1.8

Indoor Units

Floor Standing Type FVXS 25/35/50 F

Accessories
A Mounting plate

E Wireless remote controller

F Remote controller holder

C Drain hose

G AAA dry-cell batteries

D Insulation sheet

H Operation manual

B Titanium Apatite Photocatalytic

Air-Purifying Filter

Installation manual

Fixing screws for Remote


controller holder M3 20L

K Fixing screw M4 25L

3
Choosing an Installation Site
Before choosing the installation site, obtain user approval.

1.

Indoor unit.

1)
2)
3)
4)
5)
6)
7)
8)

2.

The indoor unit should be sited in a place where:


the restrictions on installation specified in the indoor unit installation drawings are met,
both air intake and exhaust have clear paths met,
the unit is not in the path of direct sunlight,
the unit is away from the source of heat or steam,
there is no source of machine oil vapour (this may shorten indoor unit life),
cool (warm) air is circulated throughout the room,
the unit is away from electronic ignition type fluorescent lamps (inverter or rapid start type) as they may shorten the remote controller range,
the unit is at least 1 m away from any television or radio set (unit may cause interference with the picture or sound).

Wireless remote controller.


1) Turn on all the fluorescent lamps in the room, if any, and find the site where remote controller signals are
properly received by the indoor unit (within 7 m).

Indoor Unit Installation Drawings


The indoor unit may be mounted in any of the three styles shown here.
Exposed

Half concealed

Location for securing the installation panel.


64

Concealed

(700)

A Mounting
plate

(Unit:mm)

150

26

134

250

Molding

Grid (field supply)

Wall Installation

230

Floor Installation

140
574
(600)

644

21
35

16
35

Front grille

70mm or more

Air filter
B Titanium Apatite Photocatalytic
Air-Purifying Filter (2)

50mm or more
from walls

E Wireless remote
controller

J Fixing screws for Remote


controller holder M3 20L

Installation Manual

Front panel

F Remote controller
holder

50mm or more
from walls

Caulk pipe
hole gap
with putty.

227

Indoor Units

EDAU12-722

Installation Tips
1.

Removing and installing front panel


Removal method
1) Slide until the 2 stoppers click into place.
2) Open the front panel forward and undo the string.
3) Remove the front panel.

Installation method
1) Attach the front grille and front panel after pulling
the string around them.
2) Close the front panel and slide until the stoppers
click outside.

2.

Removing and installing front grille

3 tabs

Removal method
1) Remove the front panel.
2) Remove the 4 screws and remove the front grille
while pulling it forward (3 tabs).
Installation method
1) Secure the front grille with the 4 installation
screws. (3 tabs)
2) Return the front panel to the original position.

Front grille
Casing

Remove
front grille

Front panel

3.

How to set the different addresses


When two indoor units are installed in one room,
Remove 4 screws.
the two wireless remote controllers can be
set for different addresses.
1) Remove the front grille.
2) Live the sensor securing plate and remove the front metal plate cover.
3) Remove connectors 5P, 6P, and 7P.
4) Remove the electric box (1 screw).
5) Remove the thermistor.
6) Remove the side metal plate cover (8 tabs).
7) Cut the address jumper (JA) on the printed circuit board.
8) Cut the address jumper (J4) in the remote controller.
5) Thermistor
3) Connector 6P

JA

JA ADRESS
1
EXIST
CUT
2

3) Connector 5P

Open the front panel

J4

2) Sensor
securing
plate

3) Connector 7P

4) Remove 1 screw.
6) Side metal plate cover
2) Front metal plate cover

228

J4 ADRESS
1
EXIST
CUT
2

Installation Manual

EDAU12-722

Indoor Units

Indoor Unit Installation (1)


Exposed installation
1.

Refrigerant piping
1)
2)
3)
4)

Drill a hole (65mm in diameter) in the spot indicated by the


symbol in the illustration as below.
The location of the hole is different depending on which side of the pipe is taken out.
For piping, see 6. Connecting the refrigerant pipe, under Indoor Unit Installation (4).
Seal the pipe end completely with a cap or tape to keep dust or moisture out.

(Unit : mm)
60

45

Wall

Left bottom piping

75

75

Right bottom piping

45
75

Right back piping

Left/right piping

45

75

45

45

Left back piping

Wall

Refrigerant pipe

75

45

Min. allowable length


The suggested shortest pipe length is 2.5m, in
order to avoid noise from the outdoor unit and
vibration.
(Mechanical noise and vibration may occur
depending on how the unit is installed and the
environment in which it is used.)
See the installation manual for the outdoor unit
for the maximum pipe length.
For multi-connections, see the installation
manual for the multi-outdoor unit.

350

CAUTION

Floor

2.

Boring a wall hole and installing wall embedded pipe


For walls containing metal frame or metal board, be sure to use a
wall embedded pipe and wall cover in the feed-through hole to
prevent possible heat, electrical shock, or fire.
Be sure to caulk the gaps around the pipes with caulking material
to prevent water leakage.
1) Bore a feed-through hole of 65mm in the wall so it has a down
slope toward the outside.
2) Insert a wall pipe into the hole.
3) Insert a wall cover into wall pipe.
4) After completing refrigerant piping, wiring, and drain piping,
caulk pipe hole gap with putty.

Installation Manual

Inside
Wall embedded pipe
(field supply)

Outside
Caulking

65

Wall hole cover


(field supply)
Wall embedded pipe
(field supply)

229

Indoor Units

EDAU12-722

Indoor Unit Installation (2)


3.

Drain piping
1) Use commercial rigid polyvinyl chloride pipe (general VP 20 pipe, outer diameter 26mm, inner
diameter 20mm) for the drain pipe.
2) The drain hose (outer diameter 18mm at connecting end, 220mm long) is supplied with the indoor
unit. Prepare the drain pipe picture below position.
3) The drain pipe should be inclined downward so that water will flow smoothly without any
accumulation. (Should not be trap.)
4) Insert the drain hose to this depth so it wont be pulled out of the drain pipe.
5) Insulate the indoor drain pipe with 10mm or more of insulation material to prevent condensation.
6) Remove the air filters and pour some water into the drain pan to check the water flows smoothly.
(Unit: mm)
150

100
100

Must be no trap.

Insert drain hose


to this depth so
it wont be pulled
out of drain pipe.

Do not touch water.


220

C Drain hose

50mm
or more
Reducer

Vinyl chloride
drain pipe
(VP-20)

Vinyl chloride
drain pipe
(VP-30)

CAUTION
Use polyvinyl chloride adhesive agent for gluing. Failure to do so may cause water leakage.

4.

Installing indoor unit

3 tabs

Front grille

Casing

4-1. Preparation
Open the front panel, remove the 4 screws and
dismount the front grille while pulling it forward.

Follow the procedure below when removing the


slit portions.

Remove
front grille
Front panel

For Moldings
Remove the pillars. (Remove the slit portions on
the bottom frame using nippers. )

For Side Piping


Remove the pillars.
1) Remove the 7 screws.
2) Remove the upper casing (2 tabs).
3) Remove the left and right casings (2 tabs on each side).
4) Remove the slit portions on the bottom frame
and casings using nippers.
5) Return by following the steps in reverse order
(3 > 2 > 1).
For Moldings

Open the front panel.

Remove 4 screws.

2) Upper casing

3) Side
casings
3) Side casings
Remove 7 screws.

Remove the pillar.

For Side Piping


Casing

Bottom frame

Casing
Remove the pillar.

Remove the pillar.

230

Installation Manual

EDAU12-722

Indoor Units

Indoor Unit Installation (3)


4-2. Installation
Secure using K 6 screws for floor installations. (Do not forget to secure to the rear wall.)
For wall installations, secure the A mounting plate using K 5 screws and the indoor unit using
K 4 screws.
The mounting plate should be installed on a wall which can support the weight of the indoor unit.
1) Temporarily secure the mounting plate to the wall, make sure that the panel is completely
level, and mark the boring points on the wall.
2) Secure the mounting plate to the wall with screws.
Floor Installation

Wall Installation

A Mounting plate

The mounting
plate should be
installed on a wall
which can support
the weight of the
indoor unit.

Casing

K 5 screws
(M4 25L)

K 6 screws (M4 25L)

K 4 screws (M4 25L)

Molding

3) Once refrigerant piping and drain piping connections are complete, fill in the gap of the
through hole with putty.
A gap can lead to condensation on the refrigerant pipe, and drain pipe, and the entry of
insects into the pipes.
4) Attach the front panel and front grille in their original positions once all connections are complete.

5.

Flaring the pipe end


1)
2)
3)
4)
5)

Cut the pipe end with a pipe cutter.


Remove burrs with the cut surface facing downward so that the chips do not enter the pipe.
Fit the flare nut on the pipe.
Flare the pipe.
Check that the flaring is properly made.

WARNING
1) Do not use mineral oil on flared part.
2) Prevent mineral oil from getting into the system as this would reduce the lifetime of the units.
3) Never use piping which has been used for previous installations. Only use parts which are delivered
with the unit.
4) Do never install a drier to this R410A unit in order to guarantee its lifetime.
5) The drying material may dissolve and damage the system.
6) Incomplete flaring may cause refrigerant gas leakage.

Flares inner
surface must
be scratch-free.

Flaring
Set exactly at the position shown below.
A

(Cut exactly
at right
angles.)

Installation Manual

Remove
burrs

Die

Flare tool for R410A

Conventional flare tool

Clutch-type

Clutch-type (Rigid-type) Wing-nut type (Imperial-type)

0-0.5mm

1.0-1.5mm

1.5-2.0mm

The pipe end must


be evenly flared in
a perfect circle.

Make sure that the


flare nut is fitted.

231

Indoor Units

EDAU12-722

Indoor Unit Installation (4)


6.

Connecting the refrigerant pipe


1) Use torque wrenches when tightening the flare nuts to prevent damage to the flare nuts and gas leaks.
Torque wrench

Coat here with refrigeration oil

Spanner

Piping union
Flare nut

2) Align the centres of both flares and tighten the flare nuts 3 or 4 turns by hand.
Then tighten them fully with the torque wrenches.
3) To prevent gas leakage, apply refrigeration oil on both inner and outer surfaces in the flare
(Use refrigeration oil for R410A).
Flare nut tightening torque
Gas side
25/35 class
3/8 inch
32.7-39.9Nm
(333-407kgfcm)

Liquid side
25/35/50 class
1/4 inch
14.2-17.2Nm
(144-175kgfcm)

50 class
1/2 inch
49.5-60.3Nm
(505-615kgfcm)

6-1. Cautions on pipe handling


1) Protect the open end of the pipe against dust and
moisture.
2) All pipe bends should be as gentle as possible. Use a
pipe bender for bending.
(Bending radius should be 30 to 40mm or larger.)

Wall

Be sure to
place a cap.
Rain

6-2. Selection of copper and heat insulation materials


When using commercial copper pipes and fittings, observe the
following:
1) Insulation material: Polyethylene foam
Heat transfer rate: 0.041 to 0.052W/mK (0.035 to 0.045kcal/(mhC))
Refrigerant gas pipes surface temperature reaches 110C max.
Choose heat insulation materials that will withstand this temperature.

If no flare cap is
available, cover
the flare mouth
with tape to keep
dirt or water out.

Inter-unit
wiring
Gas pipe

Liquid pipe

Gas pipe
insulation

Liquid pipe
Finising tape insulation

2) Be sure to insulate both the gas and liquid piping and to provide insulation dimensions as below.
Gas side
25/35 class
50 class
O.D. 9.5mm
O.D. 12.7mm
Thickness 0.8mm

Liquid side
O.D. 6.4mm

Gas pipe thermal insulation


Liquid pipe
thermal insulation
25/35 class
50 class
I.D. 12-15mm
I.D. 14-16mm
I.D. 8-10mm
Thickness 10mm Min.

3) Use separate thermal insulation pipes for gas and liquid refrigerant pipes.

7.

Checking for gas leakage


1) Check for leakage of gas after air purging.
2) See the sections on air purges and gas
leak checks in the installation manual for
the outdoor unit.

232

Check for leakage here.


Apply soapy water and
check carefully for leaking
gas.
Wipe soapy water off after
the check is complete.

Installation Manual

EDAU12-722

Indoor Units

Indoor Unit Installation (5)


8.

Attaching the connection pipe

Attach the pipe after checking for gas leakage, described right.

1)

2)

3)

Refrigerant
pipe

1) Cut the insulated portion of the on-site piping, matching it up


with the connecting portion.

Refrigerant
pipe

Refrigerant
pipe

Slit

Slit

2) Secure the slit on the refrigerant piping side with the butt
joint on the auxiliary piping using the tape, making sure
there are no gaps.

D Insulation
sheet

3) Wrap the slit and the butt joint with the included D insulation
sheet, making sure there are no gaps.

Tape
Auxiliary pipe

CAUTION
1) Insulate the joint of the pipes securely.
Incomplete insulation may lead to water leakage.
2) Push the pipe inside so it does not place undue force on the front panel.

9.

Connecting the drain hose


Insert the supplied C drain hose into the socket
of the drain pan.
Fully insert the drain hose until it adheres to a seal
of the socket.

Drain pan

Seal

Drain pan

C Drain hose

Seal

10. Wiring

C Drain hose

, install as described in the installation manual supplied with the Multi outdoor unit.
Live the sensor securing plate, remove the front metal plate cover, and connect the branch wiring to the terminal block.
Strip wire ends (15mm).
Match wire colours with terminal numbers on indoor and outdoor units terminal blocks and firmly screw wires to the corresponding terminals.
Connect the earth wires to the corresponding terminals.
Pull wires to make sure that they are securely latched up, then retain wires with wire retainer.
In case of connecting to an adapter system. Run the remote controller cable and attach the S21.
(Refer to 11. When connecting to an HA system.)

With a Multi indoor unit

1)
2)
3)
4)
5)

Sensor securing plate


Firmly fix the wires with
the terminal screws.
Outdoor unit
Shape wires so
that the front
metal plate cover
will fit securely.

Terminal block
Electrical
component
box

When wire length exceeds 10m,


use 2.0mm diameter wires.

1 23

LN

Front metal
plate cover

Firmly secure wire


retainer so that
wires sustain no
external stress.

Wire retainer

Indoor 2
3
unit

Use the specified wire type.

Firmly fix the wires with


the terminal screws.

H05VV

WARNING
1) Do not use tapped wires, stranded wires, extensioncords, or starburst connections, as they may cause overheating, electrical shock, or fire.
2) Do not use locally purchased electrical parts inside the product. (Do not branch the power for the drain pump, etc.,
from the terminal block.) Doing so may cause electric shock or fire.

11. When connecting to an HA system


1) Remove the electric box. (See 3. How to set the different addresses on page 4.)
2) Cut off the pins using a nipper.
3) Wire as shown in the diagram and connect the connection cord to the
S21 connector.
4) Attach the side metal plate cover and thermistor sensor and return the
electric box to its previous state.
5) Attach connectors 5P, 6P, and 7P.
6) Replace the front metal plate cover and the sensor securing plate.

Installation Manual

HA connector
(S21)

S2
1

Sensor
securing
plate

Side metal
plate cover

HA cord
2) Pin
Front metal plate cover

233

Indoor Units

EDAU12-722

Indoor Unit Installation (6)


Half concealed installation
Only items peculiar to this installation method are given here. See Projecting installation for additional
instructions.

1.

Wall hole

(Unit:mm)

Drill a wall hole of the size shown in the illustration on the right.

670-690

585-595

Open size

Opening hole
Floor

2.

Installation of supplemental plate for attaching main unit


The rear of the unit can be fixed with screws at the points shown in the illustration as below. Be sure
to install the supplemental plate in accordance with the depth of the inner wall.
644

95

Fixing point
on the back

150
250

(Unit:mm)

Screw hole

Screw hole

Supplemental plate
(Field supply)

140
Opening hole

230

250

Supplemental plate
(Field supply)

200

CAUTION
1) The supplemental plate for installing the main unit must be used, or there will be a gap between the
unit and the wall.

3.

Refrigerant piping
See 1. Refrigerant piping under Indoor Unit Installation (8)
Left bottom piping

Wall

Right bottom piping

50

35

Hole location

Right/left piping

45

Wall

75

75
50

234

Installation Manual

EDAU12-722

Indoor Units

Indoor Unit Installation (7)


4.

Installing the indoor unit


1)
2)
3)
4)
5)

Remove the front grille.


Remove 7 screws.
Remove the upper casing (2 tabs).
Remove the side casings (2 tabs on each side).
Attach the indoor unit to the wall and secure using K screws in 6 locations (M4 25L).
Upper casing

Side casing

K 6 screws
(M4 25L)

Remove 7 screws.

CAUTION
1) Use drain pan edge for horizontal projection of the indoor unit.
2) Install the indoor unit flush against wall.

NOTE:
For refrigerant piping, Boring a wall hole and installing wall embedded pipe, drain piping,
installing indoor unit, flaring the pipe end, connecting the refrigerant pipe, checking for gas
leakage, attaching the connection pipe, connecting the drain hose, wiring, when connecting to an
HA system, see Exposed Installation.

Concealed installation
Only items peculiar to this installation method are given here. See Exposed Installation for additional
instructions.
Install the unit according to the instructions below. Failure to do so may cause lead to both
cooling and heating failure and the condensation inside the house.
1) Allow enough space between the main unit and ceiling not to obstruct the flow of cool/warm air.
2) Place a partition plate between outlet and inlet sections.
3) Place a partition plate on the right side.
4) Change the upward-blow limit switch.
5) Use a movable lattice at the air outlet to allow the adjustment of cool/warm air flow direction.
6) Lattice size should be 70% or more of open rate.
(Unit:mm)

Right side partition plate

Partition plate
50 or more

Installation Manual

50 or more

235

Indoor Units

EDAU12-722

Indoor Unit Installation (8)


(Unit:mm)
Right side partition plate
partition plate
Movable lattice

70 or more
15-20

Upper lattice
must not
project

410

70% or more
of open rate
partition plate

120

Movable lattice

40 or less
20-30

1.

Refrigerant piping
(Unit:mm)
Left bottom piping

Right bottom piping

Right/left piping

45

60

45

Hole location

75

75
45

2.

Changing upward air flow dipswitch


Change the upward air flow dipswitch (SW2-4) to ON to limit the upward air flow.
1) Remove the front grille.
2) Switch the dipswitch (SW2-4) on the PCB in the electrical equipment box to ON.
How to set and use the switch

Upward air flow dipswitch

Switch number

SW2-4

Set function

Upward air flow limit

ON

ON

OFF

OFF

Use

Switch to on for
embedded units

Factory setting

OFF

CAUTION
Be sure to turn on the upward air flow switch. Failure to do so may cause incomplete cooling/heating and formation
of condensation inside the house.

NOTE:
For refrigerant piping, Boring a wall hole and installing wall embedded pipe, drain piping,
installing indoor unit, flaring the pipe end, connecting the refrigerant pipe, checking for gas
leakage, attaching the connection pipe, connecting the drain hose, wiring, when connecting to an
HA system, see Exposed Installation.

236

Installation Manual

EDAU12-722

Indoor Units

Trial Operation and Testing


1.

Trial operation and testing


1-1 Measure the supply voltage and make sure that it falls in the specified range.
1-2 Trial operation should be carried out in either cooling or heating mode.
For Heat pump
In cooling mode, select the lowest programmable temperature; in heating mode, select the highest
programmable temperature.
1) Trial operation may be disabled in either mode depending on the room temperature.
Use the remote controller for trial operation as described below.
2) After trial operation is complete, set the temperature to a normal level (26C to 28C in cooling
mode, 20C to 24C in heating mode).
3) For protection, the system disables restart operation for 3 minutes after it is turned off.

For Cooling only


Select the lowest programmable temperature.
1) Trial operation in cooling mode may be disabled depending on the room temperature.
Use the remote controller for trial operation as described below.
2) After trial operation is complete, set the temperature to a normal level (26C to 28C).
3) For protection, the unit disables restart operation for 3 minutes after it is turned off.
1-3 Carry out the test operation in accordance with the Operation Manual to ensure that all
functions and parts, such as louver movement, are working properly.
The air conditioner requires a small amount of power in its standby mode. If the system is not to
be used for some time after installation, shut off the circuit breaker to eliminate unnecessary
power consumption.
If the circuit breaker trips to shut off the power to the air conditioner, the system will restore the
original operation mode when the circuit breaker is opened again.

Trial Operation from Remote Controller


1) Press ON/OFF button to turn on the system.
2) Press TEMP (2 locations) and MODE at the same time.
3) Press MODE button twice.
( will appear on the display to indicate that Trial Operation mode is selected.)
4) Trial run mode terminates in approx. 30 minutes and switches into normal mode. To quit a trial operation, press ON/OFF
button.

2.

Test items
Test Items

Symptom

Check

Indoor and outdoor units are installed properly on solid bases. Fall, vibration, noise
Incomplete cooling/heating
No refrigerant gas leaks.
function
Refrigerant gas and liquid pipes and indoor drain hose
extension are thermally insulated.

Water leakage

Draining line is properly installed.


System is properly earthed.
The specified wires are used for inter-unit wiring connections.
Indoor or outdoor units air intake or exhaust has clear path of air.
Stop valves are opened.

Water leakage
Electrical leakage
Inoperative or burn damage
Incomplete cooling/heating
function

Indoor unit properly receives remote control commands.

Inoperative

3P191294-1A

Installation Manual

237

Indoor Units

1.9

EDAU12-722

Ceiling Mounted Cassette Type FFQ 25/35/50/60 B


1. SAFETY CONSIDERATIONS
Please read these SAFETY CONSIDERATIONS carefully before installing air conditioning equipment and
be sure to install it correctly. After completing the installation, make sure that the unit operates properly during the start-up operation. Please instruct the customer how to operate the unit and keep it maintained.
Also, inform customers that they should store this installation manual along with the operation manual for
future reference.
This air conditioner comes under the term appliances not accesible to the general public.
Meaning of warning and caution symbols
WARNING..........Failure to observe a warning may result in death.
CAUTION ...........Failure to observe a caution may result in injury or damage to the equipment.
WARNING
Ask your dealer or qualified personnel to carry out installation work. Do not try to install the machine yourself.
Improper installation may result in water leakage, electric shocks or fire.
Perform installation work in accordance with this installation manual.
Improper installation may result in water leakage, electric shocks or fire.
Be sure to use only the specified accessories and parts for installation work.
Failure to use the specified parts may result in water leakage, electric shocks, fire or the unit falling.
Install the air conditioner on a foundation strong enough to withstand the weight of the unit.
A foundation of insufficient strength may result in the equipment falling and causing injuries.
Carry out the specified installation work after taking into account strong winds, typhoons or earthquakes.
Improper installation work may result in the equipment falling and accidents.
Make sure that a separate power supply circuit is provided for this unit and that all electrical work is carried out by qualified personnel according to local laws and regulations and this installation manual.
An insufficient power supply capacity or improper electrical construction may lead to electric shocks or
fire.
Make sure that all wiring is secured, the specified wires are used, and no external forces act on the terminal connections or wires.
Improper connections or installation may result in fire.
When wiring the power supply and connecting the wiring between the indoor and outdoor units, position
the wires so that the control box lid can be securely fastened.
Improper positioning of the control box lid may result in electric shocks, fire or the terminals overheating.
If the refrigerant gas leaks during installation, ventilate the area immediately.
Toxic gas may be produced if the refrigerant gas comes into contact with fire.
After completing the installation work, check that the refrigerant gas does not leak.
Toxic gas may be produced if the refrigerant gas leaks into the room and comes into contact with a source
of fire, such as a fan heater, stove or cooker.
Before touching electrical parts, turn off the unit.

238

Installation Manual

EDAU12-722

Indoor Units

CAUTION
Ground the air conditioner.
Do not connect the ground wire to gas or water pipes, lightning rods or telephone ground wires. Incomplete grounding may result in electric shocks.
Be sure to install an earth leakage breaker.
Failure to install an earth leakage breaker may result in electric shocks.
While following the instructions in this installation manual, install drain piping in order to ensure proper
drainage and insulate piping in order to prevent condensation.
Improper drain piping may result in water leakage and property damage.
Install the indoor and outdoor units, power cord and connecting wires at least 1 meter away from televisions or radios in order to prevent image interference or noise.
(Depending on the radio waves, a distance of 1 meter may not be sufficient enough to eliminate the
noise.)
Remote controller (wireless kit) transmitting distance can result shorter than expected in rooms with electronic fluorescent lamps. (inverter or rapid start types)
Install the indoor unit as far away from fluorescent lamps as possible.
Do not install the air conditioner in the following locations:
(a) where a mineral oil mist or an oil spray or vapor is produced, for example in a kitchen
Plastic parts may deteriorate and fall off or result in water leakage.
(b) where corrosive gas, such as sulfurous acid gas, is produced
Corroding copper pipes or soldered parts may result in refrigerant leakage.
(c) near machinery emitting electromagnetic waves
Electromagnetic waves may disturb the operation of the control system and result in a
malfunction of the equipment.
(d) where flammable gases may leak, where there are carbon fiber or ignitable dust suspensions in the
air, or where volatile flammables such as thinner or gasoline are handled.
Operating the unit in such conditions may result in fire.

Installation Manual

239

Indoor Units

EDAU12-722

2. BEFORE INSTALLATION
When moving the unit while removing it from the carton box, be sure to lift it by holding on to the
four lifting lugs without exerting any pressure on other parts, especially, the refrigerant piping, drain
piping, and other resin parts.
Be sure to check the type of R410A refrigerant to be used before installing the unit.(Using an incorrect
refrigerant will prevent normal operation of the unit.)
The accessories needed for installation must be retained in your custody until the installation work is completed. Do not discard them!
Decide upon a line of transport.
Leave the unit inside its packaging while moving, until reaching the installation site. Where unpacking is
unavoidable, use a sling of soft material or protective plates together with a rope when lifting, to avoid
damage or scratches to the unit.
Especially, do not unfasten packing case(top) guarding the control box until suspending the unit.
When selecting installation site, refer to the paper pattern.
For the installation of an outdoor unit, refer to the installation manual attached to the outdoor unit.
Do not use the unit in locations with high salt content in the air such as beachfront property, locations
where the voltage fluctuates such as factories, or in automobiles or marine vessels.

2-1

ACCESSORIES

Check the following accessories are included with your unit.

Name

(1)Drain hose

(2)Clamp

(3)Washer for
hanging bracket

Quantity

1 pc.

1 pc.

8 pcs.

(4)Clamp
(Big)
6 pcs.

(Small)
1 pc.

(5)Paper pattern
for installation
1 pc.
Also used as
packing material

Shape

Name

(6)Screws
(M5)

Quantity

4 pcs.

(7)Washer
Insulation for fitting
fixing plate
4 pcs.

For paper pattern


for installation

1 each.
(8)For gas pipe

Sealing pad
1 each.

(12)Sealing
material
2 pcs.

(10)Large

Operation
manual
Installation
manual

Shape
(9)For liquid pipe

2-2

(Other)

(11)Small

OPTIONAL ACCESSORIES

The optional decoration panel and remote controller are required for this indoor unit.(Refer to Table 1, 2)
Table 1
Unit model
FFQ25355060BV1B

240

Optional decoration panel


BYFQ60BW1
Colour : White

Installation Manual

EDAU12-722

Indoor Units

These are two types of remote controllers: wired and wireless. Select a remote controller from Table 2
according to customer request and install in an appropriate place.
Table 2
Remote controller type
Wired type
Wireless type

European market
Cooling only type
Heat Pump type
BRC1C517
BRC7E531W
BRC7E530W

Australian market
Cooling only type
Heat Pump type
BRC1C61
BRC7E531W
BRC7E530W

NOTE
If you wish to use a remote controller that is not listed in Table 2 on page 4, select a suitable remote
controller after consulting catalogs and technical materials .

FOR THE FOLLOWING ITEMS, TAKE SPECIAL CARE DURING CONSTRUCTION AND
CHECK AFTER INSTALLATION IS FINISHED.
a. Items to be checked after completion of work
Items to be checked
Are the indoor and outdoor unit fixed firmly?
Is the gas leak test finished?
Is the unit fully insulated?
Dose drainage flow smoothly?
Dose the power supply voltage correspond
to that shown on the name plate?
Are wiring and piping correct?
Is the unit safely grounded?
Is wiring size according to specifications?
Is something blocking the air outlet or inlet
of either the indoor or outdoor units?
Are refrigerant piping length and additional
refrigerant charge noted down?

If not properly done, what is likely to occur


The units may drop, vibrate or make noise.
It may result in insuffcient cooling.
Condensate water may drip.
Condensate water may drip.
The unit may malfunction or the components burn out.
The unit may malfunction or the components burn out.
Dangerous at electric leakage.
The unit may malfunction or the components burn out.

Check

It may result in insufficient cooling.


The refrigerant charge in the system is not
clear.

b. Items to be checked at time of delivery

Also review the SAFETY CONSIDERATIONS


Items to be checked
Did you explain about operations while showing the instruction manual to your customer?
Did you hand the instruction manual over to your customer?

Check

c. Points for explanation about operations


The items with
WARNING and
CAUTION marks in the instruction manual are the items pertaining to possibillties for bodily injury and material damage in addition to the general usage of
the product. Accordingly, it is necessary that you make a full explanation about the described contents
and also ask your customers to read the instruction manual.

2-3

NOTE TO THE INSTALLER

Be sure to instruct customers how to properly operate the unit (especially cleaning filters, operating different functions, and adjusting the temperature) by having them carry out operations themselves while looking at the manual.

Installation Manual

241

Indoor Units

EDAU12-722

3. SELECTING INSTALLATION SITE


Please attach additional thermal insulation material to the unit body when it is believed that the relative
humidity in the ceiling exceeds 80%. Use glass wool, polyethylene foam, or similar with a thickness of 10
mm or more as thermal insulation material.
For this unit, you are able to select air flow direction.
To enable the discharge of air in 2 or 3 directions, it is necessary to purchase the sealing member of air discharge outlet.
(1) Select an installation site where the following conditions are fulfilled and that meets your customer's approval.
In the upper space (including the back of the ceiling) of the indoor unit where there is no possible dripping of water from the refrigerant pipe, drain pipe, water pipe, etc.
Where optimum air distribution can be ensured.
Where nothing blocks air passage.
Where condensate can be properly drained.
Where the ceiling is strong enough to bear the indoor unit weight.
Where the false ceiling is not noticeably on an incline.
Where sufficient clearance for maintenance and service can be ensured.
Where there is no risk of flammable gas leakage.
Where piping between indoor and outdoor units is possible within the allowable limit.
(Refer to the installation manual for the outdoor unit.)

[Space required for installation] (mm)


>

>

* 1500

Air
outlet

* 1500

1500

2500

>

>

>

For installation
in high places

* 1500

Air
Air outlet
inlet

>

* 1500

>

* 1500

Fig. 1

>

* 1500

Fig. 2
NOTE
Leave 200 mm or more space where marked with the *, on sides where the air outlet is closed.
Model

FFQ25355060

285 (Confirm the space of 295 or more)

CAUTION
Install the indoor and outdoor units, power cord and connecting wires at least 1 meter away from televisions or radios in order to prevent image interference or noise.
(Depending on the radio waves, a distance of 1 meter may not be sufficient enough to eliminate the
noise.)
(2) Air flow direction
Select the air flow directions best suited to the room and point of installation. (For air outlet in 2 or 3 directions, it is necessary to make field settings by remote controller and to close the air outlet(s). Refer to the
installation manual of the sealing member of air discharge outlet and the section entitled 10. FIELD SETTING)

242

Installation Manual

EDAU12-722

Indoor Units

[Air flow direction] (Example)


Piping

Piping

Air outlet in
4 directions

Piping

Air outlet in
3 directions

Air outlet in
2 directions

(3) Use suspension bolts for installation. Check whether the ceiling is strong enough to support the
weight of the unit or not. If there is a risk, reinforce the ceiling before installing the unit.
(Installation pitch is maked on the paper pattern for installation. Refer to it to check for points requiring
reinforcing.)

4. PREPARATIONS BEFORE INSTALLATION


(1) Relation of ceiling opening to unit and suspension bolt position.

Suspension
bolt ( 4)

533 (Suspension bolt pitch)


575 (indoor unit)
585-660 (Ceiling opening)
700 (Decoration panel)

(Ceiling opening dimension)


585 *660
Hanger
bracket

False
ceiling

20

20

(Ceiling-panel overlapping dimension)


View as seen from A
Fig. 3
Fig. 4

(180)

700 (Decoration panel)


585-660 (Ceiling opening)
575 (indoor unit)
533 (Suspension bolt pitch)

Refrigerant
piping

(mm)

A
NOTE
Installation is possible with a ceiling dimension of 660 mm (marked with *). However, to achieve a ceilingpanel overlapping dimension of 20 mm, the spacing between the ceiling and the unit should be 45 mm or
less. If the spacing between ceiling and the unit is over 45 mm, attach ceiling material to
part or
recover the ceiling.

False
ceiling

False
ceiling

Ceiling material
< 45

< 45

(mm)
Fig. 5

(2) Make the ceiling opening needed for installation where applicable. (For existing ceilings)
Refer to the paper pattern for installation (5) for ceiling opening dimensions.
Create the ceiling opening required for installation. From the side of the opening to the casing outlet,implement the refrigerant and drain piping and wiring for remote controller (unnecessary for wireless type) and wiring between units. Refer to each PIPING or WIRING section.
After making an opening in the ceiling, it may be necessary to reinforce ceiling beams to keep the ceiling level and to prevent it from vibrating. Consult the builder for details.

Installation Manual

243

Indoor Units

EDAU12-722

(3) Install the suspension bolts.


(Use either a M8 ~ M10 size bolt)
Use a hole-in anchor for existing ceilings, and
a sunken insert, sunken anchor or other field
supplied parts for new ceilings to reinforce
the ceiling to bear the weight of the unit.
Adjust clearance (50 100 mm) from the
ceiling before proceeding further.

<installation example>
Ceiling slab
Anchor
Long nut or turn-buckle
Suspension bolt
False ceiling

NOTE
All the above parts are field supplied.

(mm)

Fig. 6

5. INDOOR UNIT INSTALLATION


As for the parts to be used for installation work, be sure to use the provided accessories and specified parts
designated by our company.
(1) For new ceilings
(1-1) Install the indoor unit temporarily.
Attach the hanger bracket to the suspension bolt. Be sure to fix it securely by using a nut and
washer (3) from the upper and lower sides of the hanger bracket.
The washer fixing plate (7) will prevent the washer from falling.

Nut (Field supplied)


Washer (3) (attached)
Insert
Hanger bracket

Washer fixing plate (7)


(attached)

Tighten
(double nut)

[Securing the washer]

[Securing the hanger bracket]


Fig. 7

Fig. 8

(1-2) Refer to the paper pattern for installation (5) for ceilling opening dimension.
Consult the builder or carpenter for details.
The center of the ceiling opening is indicated on the paper pattern for installation.
The center of the unit is indicated on the paper pattern for installation.
Fix the paper pattern to the unit with screws (6) (4).

Paper pattern for installation (5)


(attached)

Screws (6)
(attached)
Screws (6)
(attached) [Installation of paper pattern for installation]
Fig. 9

244

Installation Manual

EDAU12-722

Indoor Units

<Ceiling work>
(1-3) Adjust the unit to the right position for installation.
(Refer to 4.PREPARATIONS BEFORE INSTALLATION-(1). )
(1-4) Check the unit is horizontally level.
CAUTION
The indoor unit is equipped with a built-in drain
pump and float switch. Verify that it is level by using
a water level or a waterfilled vinyl tube.
(If the unit is tilted against condensate flow, the float
switch may malfunction and cause water to drip.)
(1-5) Remove the washer fixing plate (7) used for preventing the washer from falling and tighten the
upper nut.
(1-6) Remove the paper pattern for installation (5).

3
Water level

Vinyl tube

[Maintaining horizontality]

Fig. 10
(2) For existing ceilings
(2-1) Install the indoor unit temporarily.
Attach the hanger bracket to the suspension bolt. Be sure to fix it securely by using a nut and
washer (3) from the upper and lower sides of hanger bracket. The washer fixing plate (7) will prevent the washer from falling.
Nut (Field supplied)
Washer (3) (attached)
Insert
Hanger bracket
Tighten
(double nut)

Washer fixing plate (7)


(attached)
[Securing the washer]

[Securing the hanger bracket]


Fig. 11

Fig. 12

(2-2) Adjust the height and position of the unit.


(Refer to 4.PREPARATIONS BEFORE INSTALLATION-(1).)
(2-3) Perform steps (1-4), (1-5) in (1) For new ceilings.

Installation Manual

245

Indoor Units

EDAU12-722

6. REFRIGERANT PIPING WORK


<For refrigerant piping of outdoor units, see the installation manual attached to the outdoor unit.>
<Execute heat insulation work completely on both sides of the gas piping and the liquid piping.
Otherwise, a water leakage can result sometimes.>
(When using a heat pump, the temperature of the gas piping can reach up to approximately 120 C, so use
insulation which is sufficiently resistant.)
<Also, in cases where the temperature and humidity of the refrigerant piping sections might exceed
30 C or RH80%, reinforce the refrigerant insulation. (20 mm or thicker) Condensation may form on
the surface of the insulating material.>
<Before refrigerant piping work, check which type of refrigerant is used. Proper operation is not possible if the types of refrigerant are not the same.>
CAUTION
Use a pipe cutter and flare suitable for the type of refrigerant.
Apply ester oil or ether oil around the flare portions before connectiong.
To prevent dust, moisuture or other foreign matter from infiltrating the tube, either pinch the end
or cover it with tape.
Do not allow anything other than the designated refrigerant to get mixed into the refrigerant circuit, such as air, etc. If any refrigerant gas leaks while working on the unit, ventilate the room
thoroughly right away.
The outdoor unit is charged with refrigerant.
Be sure to use both a spanner and torque wrench together, as
shown in the drawing, when connecting or disconnecting pipes to/
from the unit. (Refer to Fig. 13)
Refer to Table 3 for the dimensions of flare nut spaces.
When connecting the flare nut, coat the flare section (both inside and
outside) with ester oil or ether oil, rotate three or four times first,
then screw in. (Refer to Fig. 14)

Torque wrench

Spanner
Piping union

CAUTION

Flare nut

Over-tightening may damage the flare and cause


a refrigerant leakage.

Ester oil or ether oil

NOTE
Use the flare nut included with the unit main body.
Table 3
Pipe size

Tightening torque

6.4(1/4")

14.2 - 17.2 Nm
(144 - 175 kgfcm)
32.7 - 39.9 Nm
(333 - 407 kgfcm)

9.5(3/8")
12.7(1/2")

49.5 - 60.3 Nm
(505 - 615 kgfcm)

Fig. 13

Fig. 14

Flare dimensions
A (mm)

Flare

8.7-9.1
12.8-13.2
16.2 - 16.6

Refer to Table 3 to determine the proper tightening torque.


CAUTION
Over-tightening may damage the flare and cause a refrigerant leakage.

246

Installation Manual

EDAU12-722

Indoor Units

Not recommendable but in case of emergency


You must use a torque wrench but if you are obliged to install the unit without a torque wrench, you may follow the installation method mentioned below.
After the work is finished, make sure to check that there is no gas leak.
When you keep on tightening the flare nut with a spanner, there is a point where the tightening torque suddenly increases. From that position, further tighten the flare nut the angle shown below:
Pipe size
6.4 (1/4")
9.5 (3/8")
12.7 (1/2")

Further tightening angle


60 to 90 degrees
60 to 90 degrees
30 to 60 degrees

Recommended arm length of tool


Approx. 150mm
Approx. 200mm
Approx. 250mm

CAUTION
CAUTION TO BE TAKEN WHEN BRAZING REFRIGERANT PIPING
Do not use flux when brazing refrigerant piping. Therefore, use the phosphor copper brazing filter metal
(BCuP) which does not require flux.
(Flux has extremely harmful infulence on refrigerant piping sysems. For instance, if the chlorine based
flux is used, it will cause pipe corrosion or, in particular, if the flux contains fluorine, it will damage the
refrigerant oil.)
Before brazing local refrigerant piping, nitrogen gas shall be blown through the piping to expel air from the
piping.
If your brazing is done without nitrogen gas blowing, a large amount of oxide film develops inside the piping, and could cause system malfunction.
When brazing the refrigerant piping, only begin brazing after having carried out nitrogen substitution or
while inserting nitrogen into the refrigerant piping. Once this is done, connect the indoor unit with a flared
or a flanged connection.
Nitrogen should be set to 0.02 Mpa (0.2 kg/cm2) with a pressure-reducing valve if brazing while inserting
nitrogen into the piping. (Refer to Fig.15)

Taping

Refrigerant piping

Pressure-reducing valve
Part to be
brazed

hands valve

Nitrogen

Nitrogen
Fig. 15

Make absolutely sure to execute heat insulation works on the pipe-connecting section after checking gas
leakage by thoroughly studying the following figure and using the attached heat insulating materials for fitting (8) and (9). (Fasten both ends with the clamps (4).)
(Refer to Fig. 16)
Wrap the sealing pad (11) only around the insulation for the joints on the gas piping side.
(Refer to Fig. 16)

Installation Manual

247

Indoor Units

EDAU12-722

Small sealing pad


(attached) (11)
(Wrap the piping union
with the sealing pad.)
Insulation for fitting
(attached) (9)
(for liquid pipe)

Clamp (4)
(Big 4)
(attached)

Liquid piping

Insulation for fitting (attached) (8)


(for gas pipe)
Gas piping

Fig. 16

CAUTION
Be sure to insulate any field piping all the way to the piping connection inside the unit. Any exposed piping
may cause condensation or burns if touched.

7. DRAIN PIPING WORK


(1) Carry out the drain piping
Lay pipes so as to ensure that drainage can occur with problems.
Employ a pipe with either the same diameter or with the diameter larger (excluding the raising section)
than that of the connecting pipe (PVC pipe, nominal diameter 20 mm, outside diameter 26 mm).
keep the drain pipe short and sloping downwards at a gradient of at least 1/100 to prevent air pockets from
forming.
If the drain hose cannot be sufficiently set on a slope, refer to PRECAUTIONS FOR DRAIN RAISING PIPING on page 12.
To keep the drain hose from sagging, space hanger bracket every 1 to 1.5 m.

Hanger bracket
GOOD
Fig. 17

1/100
gradient or more

WRONG

WRONG
Fig. 18

Use the attached drain hose (1) and clamp (2).


Insert the drain hose into the drain socket up to the base, and tighten the clamp securely within the portion
of a gray tape of the hose-inserted tip. Tighten the clamp until the screw head is less than 4 mm from the
hose.
Make sure that heat insulation work is executed on the following 2 spots to prevent any possible water
leakage due to dew condensation.
Indoor drain pipe
Drain socket
Wrap the attached sealing pad (10) over the clamp and drain hose to insulate.

248

Installation Manual

EDAU12-722

Indoor Units

Clamp (2)
(attached)

Clamp (2)
(attached)

Large sealing pad (10)


(attached)

Drain hose (1)


(attached)

Tape (Gray)

4mm

Fig. 19

Fig. 20

<PRECAUTIONS FOR DRAIN RAISING PIPING>


Install the drain raising pipes at a height of less than 545 mm.
Install the drain raising pipes at a right angle to the indoor unit and no more than 300 mm from the unit.

Hanger bracket

Ceiling slab

Adjustable
( 545)
205

1-1.5m

Clamp (2)
(attached)

750

300

Drain hose (attached)(1)

(mm)

Drain raising pipe


Raising section

Fig. 21

100mm

NOTE
To ensure no excessive pressure is applied to the included drain hose (1), do not bend or twist when
installing. (This may cause leakage.)
If converging multiple drain pipes, install according to the procedure shown below.

Slope downwards at a
gradient of at least 1/100 to
prevent air pockets from forming
T-joint converging drain pipes
Fig. 22

Select converging drain pipes whose gauge is suitable for the operating capacity of the unit.
(2) After piping work is finished, check if drainage flows smoothly.
Add approximately 1000 cc of water slowly from the air outlet and check drainage flow.
WHEN ELECTRIC WIRING WORK IS FINISHED
Check drainage flow during cooling operation.
WHEN ELECTRIC WIRING WORK IS NOT FINISHED
Remove the control box lid. Connect the single phase power supply (SINGLE PHASE 50Hz 220-240V) to
connections No.1 and No.2 on the power supply terminal block. Do not connect to No.3 of the power supply terminal block. (The drain pump will not operate.) When carrying out wiring work around the control
box, make sure none of the connectors come undone. Be sure to attach the control box lid before turning
on the power.
After confirming drainage (Fig.23, Fig.24), turn off the power and remove the power supply.
Attach the control box lid as before.

Installation Manual

249

Indoor Units

EDAU12-722

Drain pipe

Fig. 23

100

(mm)

Plastic container
for pouring
(Tube should be
about 100 mm long.)

Service drain outlet (with rubber plug)


(Use this outlet to drain water from
the drain pan)
<Adding water through air outlet>
[Method of adding water]

Control
box lid

Remove the
control box lid
(take off 2 screws)

Power supply
terminal block

No.3
No.1 No.2

Single phase
power supply
(50Hz 220-240V)

Fig. 24

CAUTION
Drain piping connections
Do not connect the drain piping directly to sewage pipes that smell of ammonia. The ammonia in the sewage
might enter the indoor unit through the drain pipes and corrode the heat exchanger.
Keep in mind that it will become the cause of getting drain pipe blocked if water collects on drain pipe.

250

Installation Manual

EDAU12-722

Indoor Units

8. WIRING EXAMPLE
For the wiring of outdoor units, refer to the installation manual attached to the outdoor units.
Confirm the system type.
Pair type : 1 remote controller controls 1 indoor unit. (standard system) (Refer to Fig. 25)
Multi system: 1 through 4 indoor units connect to 1 outdoor unit. The indoor unit is controlled by remote
controller connected to each indoor unit. (Refer to Fig. 26)
However, the group control is not expected.
Group control: 1 remote controller controls up to 16 indoor units. (All indoor units operate according to
the remote controller) (Refer to Fig. 27)
2 remote controllers control: 2 remote controllers control 1 indoor unit. (Refer to Fig. 28)

Multi system

Pair type

Main power supply

Main power supply

Main switch
Fuse

Main switch
Fuse
Outdoor unit

Outdoor unit

1 2 3

1 2 3

1 2 3

1 2 3

P1 P2

P1 P2

Indoor
unit

Indoor unit
P1 P2

Remote controller
(Optional accessories)

Fig. 25

1 2 3

1 2 3

1 2 3

P1 P2

P1 P2

Indoor
unit
P1 P2

Fig. 26

1 2 3

Indoor
unit
P1 P2

P1 P2

Remote controller
(Optional accessories)

Group control

2 remote controllers control

Main power supply

Main power supply

Main power supply

Main power supply

Main switch
Fuse

Main switch
Fuse

Main switch
Fuse

Main switch
Fuse

Outdoor unit

Outdoor unit

Outdoor unit

Outdoor unit

1 2 3

1 2 3

1 2 3

1 2 3

1 2 3

1 2 3
P1 P2

1 2 3
P1 P2

Indoor unit

Indoor unit
P1 P2

Remote controller
(Optional accessories)

Fig. 27

1 2 3
P1 P2

Indoor unit

P1 P2

Indoor unit
Remote
controller 1 P P
(Optional
accessories)
1

P1 P2

Fig. 28

Remote
controller 2
(Optional
accessories)

NOTE
1. All transmission wiring except for the remote controller wires is polarized and must match the terminal symbol.
of a remote controller
2. In case a shielding wire is to be used, connect a shielded portion with the
terminal board.(Also, connect the ground for the remote control to a grounded metal part.)
3. For group control remote controller, choose the remote controller that suits the indoor unit which has
the most functions (as attached swing flap)

Installation Manual

251

Indoor Units

EDAU12-722

9. ELECTRIC WIRING WORK

All field supplied parts and materials and electric works must conform to local codes.
Use copper wire only.
For electric wiring work, refer to also Wiring diagram label attached to the Control box lid.
For remote controller wiring details, refer to the installation manual attached to the remote controller.
All wiring must be performed by an authorized electrician.
A circuit breaker capable of shutting down power supply to the entire system must be installed.
Refer to the installation manual attached to the outdoor unit for the size of power supply electric wire connected to the outdoor unit, the capacity of the circuit breaker and switch, and wiring instructions.
Be sure to ground the air conditioner.
Do not connect the ground wire to gas and water pipes, lightning rods, or telephone ground wires.
Gas pipes : might cause explosions or fire if gas leaks.
Water pipes : no grounding effect if hard vinyl piping is used.
Telephone ground wires or lightning rods : might cause abnormally high electric potential in the ground
during lighting storms.
Specifications for field wire
Table 4
Wire
Wiring between units

H05VV-U4G(NOTE 1)

Remote controller cord

Vinyl cord with sheath or cable (2 wire) (NOTE 2)

Wiring to ground terminal

Ground wire conform to local codes

Size(mm2)

Length

2.5

0.75-1.25

Max.500m *

2.0

*This will be the total extended length in the system when doing group control.
NOTE
1. Shows only in case of protected pipes. Use H07RN-F in case of no protection.
2. For European and Asian market : Vinyl cord with sheath or cable (Insulated thickness : 1mm or more)
For Australian regular : Shield wire (Insulated thickness : 1mm or more)
CAUTION
Arrange the wires and fix a lid firmly so that the lid does not float during wiring work.
Do not clamp remote controller cords together with wiring between units together. Doing so may cause
malfunction.
Remote controller cords and wiring between units should be located at least 50 mm from other electric
wires. Not following this guideline may result in malfunction due to electrical noise.
Connection of wiring between units, ground wire and for the remote control cord (Refer to Fig. 29)
Wiring between units and ground wire
Remove the control box lid and connect wires of matching number to the power supply terminal block
(4P)inside. And connect the ground wire to the terminal block. In doing this, pull the wires inside through
the hole and fix the wires securely with the included clamp (4).
Give enough slack to the wires between the clamp (4) and power supply terminal block. (Use Fig. 30 as a
guide and allow at least 80mm for removing the sheath.)
Remove the control box lid and pull the wires inside through the hole and connect to the terminal block for
remote controller (6P). (no polarity) Securely fix the remote controller cord with the included clamp (4).
Give enough slack to the wires between the clamp (4) and the terminal block for the remote controller.
After connection, attach sealing material (12)
Be sure to attach it to prevent the infiltration of water as well as any insects and other small creatures from
the outside. Otherwise a short circuit may occur inside the control box.

252

Installation Manual

EDAU12-722

Indoor Units

Wiring Remote controller cord

Remote controller cord

the shield part of shielded wire.


(Ground
Refer to Note 2 in "8. WIRING EXAMPLE")
Note

Terminal block for


remote controller (6P)
15
10~
mm

control box lid

After clamping
Clamp(4)(small)
(attached)
to wire sheath,
Clamp(4)
clamp the wire
(Big)
(attached) sheath with
Clamp(4) Clamp(4)(Big)
(Small)
to clamp
material.
Be sure to clamp
wire sheath.
After securing the
Clamp
clamp (4) to clamp
material
material, cut off
any extra material

Wiring diagram label


(Back side of control box lid)

Remove the
control box lid
(take off 2
screws)

Wiring between units


Outdoor
unit

Note

Indoor
unit

(Wiring between units)


How to connect power
supply terminal block
(4P) with ground wire

10~15mm

Wiring between
units

Clamp(4)
(Big)
(attached)

Clamp
material

Power supply
terminal block

Be sure to clamp
wire sheath.
After securing the
clamp (4) to clamp material,
cut off any extra material

Fig. 29

Note)
Be sure to attach it to prevent the infiltration of water
as well as any insects and other small creatures from
the outside. Otherwise a short circuit may occur
inside the control box.
(attached)
Sealing material (12)
Attach completely to
hole of wiring without
leaving any space

Sealing
material(12)
(attached)

Wiring

(Outside)

(Inside)

Wiring to
outside

[How to attach sealing materials]

Observe the notes mentioned below when wiring to the power supply terminal block.
Tightening torque for the terminal blocks.
Use the correct screwdriver for tightening the terminal screws. If the blade of screwdriver is too small, the
head of the screw might be damaged, and the screw will not be properly tightened.
If the terminal screws are tightened too hard, screws might be damaged.
Refer to the table below for the tightening torque of the terminal screws.
Tightening torque

Installation Manual

Terminal block for remote controller (6P)

0.79 - 0.97 Nm

Power supply terminal block (4P)

1.18 - 1.44 Nm

253

Indoor Units

EDAU12-722

Precautions to be taken for power supply wiring


Use a round crimp-style terminal for connection to the power supply terminal block. In case it cannot be
used due to unavoidable reasons, be sure to observe the following instructions.
Be sure to peel off the sheath of wiring between units more than 80 mm.
(Refer to Fig. 30)
In wiring, make certain that prescribed wires are used, carry out complete connections, and fix the wires
so that external forces are not applied to the terminals.

Attach insulation sleeve


Round crimp-style terminal
Wiring between units

or

Fig. 30

mm
80

m
or

CAUTION
When clamping the wires, be sure no pressure is applied to the wire connections by using the included
clamping material to make appropriate clamps. Also, when wiring, make sure the lid on the control box
fits snugly by arranging the wires neatly and attaching the control box lid firmly. When attaching the control
box lid, make sure no wires get caught in the edges. Pass wiring through the wiring through holes to prevent
damage to them.
Make sure the remote control cord, the wiring between units, and other electrical wiring do not pass through
the same locations outside the machine, separating them by at least 50mm, otherwise electrical noise
(external static) could cause mistaken operation or breakage.

254

Installation Manual

EDAU12-722

Indoor Units

10. FIELD SETTINGS


(1) Make sure the control box lids are closed on the indoor and outdoor units.
(2) Field settings must be made from the remote controller and in accordance with installation conditions.
Setting can be made by changing the Mode No., FIRST CODE NO. and SECOND CODE NO..
The Field Settings included with the remote control lists the order of the settings and method of operation.

10-1 Setting air outlet direction

For changing air outlet direction (2 or 3 directions), refer to the optional installation manual of the sealing
member of air discharge outlet kit or the service manual.
(SECOND CODE NO. is factory set to 01 for air outlet in 4 directions.)

10-2 Setting for options


For settings for options, see the installation instructions provided with the option.

10-3 Setting air filter sign


Remote controllers are equiped with liquid crystal display air filer signs to display the time to clean air filters.
Change the SECOND CODE NO. according to Table 5 depending on the amount of dirt or dust in
the room.
(SECOND CODE NO. is factory set to 01 for air filter contamination-light.)
Table5
Setting
Air filter contaminationlight
Air filter contaminationheavy

Spacing time of display air filter


sign (long life type)

Mode No.

FIRST CODE
NO.

10 (20)

Approx. 2500 hrs

SECOND
CODE NO.
01

Approx. 1250 hrs

02

10-4 When implementing group control


When using as a pair unit, you may control up to 16 unit with the remote controller.
In this case, all the indoor units in the group will operate in accordance with the group control remote controller.
Select a remote controller which matches as many of the functions (swing flap, etc) in the group as possible.
Outdoor unit 1
Indoor unit 1

Outdoor unit 2

Indoor unit 2

Outdoor unit 3

Indoor unit 3

Group control remote controller

Wiring Method (See 9. ELECTRIC WIRING WORK on page 15.)


(1) Remove the control box lid.
(2) Cross-wire the remote control terminal block (P1 P 2) inside the control box. (There is no polarity.)
(Refer to Fig. 27 on page 14 and Table 4 on page 15)

10-5 Two remote Controllers (Controlling 1 indoor unit by 2 remote controllers)


When using 2 remote controllers, one must be set to MAIN and the other to SUB.

Installation Manual

255

Indoor Units

EDAU12-722

MAIN/SUB CHANGEOVER
screwdriver into the recess between the upper and lower part of remote controller and, work(1) Insert a
ing from the 2 positions, pry off the upper part. (The remote controller PC board is attached to the upper
part of remote controller.) (Refer to Fig. 31)
(2) Turn the main/sub changeover switch on one of the two remote controller PC boards to S. (Leave the
switch of the other remote controller set to M.) (Refer to Fig. 32)
Fig. 31

Fig. 32

Upper part of
remote controller

Insert the screwdriver


here and gently work
off the upper part of
remote controller.

Lower part of
remote controller

(Factory setting)

S
M

(Only one remote


controller needs S
to be changed if M
factory settings
have remained
untouched.)

Remote
controller
PC board

Wiring Method (See 9. ELECTRIC WIRING WORK on page15. )


(3) Remove the control box lid.
(4) Add remote controller 2 to the remote control terminal block (P 1, P 2) in the control box.
(There is no polarity.) (Refer to Fig. 28 on page 14 and Table 4 on page 15)

11. INSTALLATION OF THE DECORATION PANEL


<Read 12. TEST OPERATION before making a test run without attaching the decorated panels.>
Refer to the installation manual attached to the decoration panel.
After installing the decoration panel, ensure that there is no space between the unit body and decoration
panel.

12. TEST OPERATION


(1) Make sure the control box lids are closed on the indoor and outdoor units.
(2) Refer to the section of FOR THE FOLLOWING ITEMS, TAKE SPECIAL CARE DURING CONSTRUCTION AND CHECK AFTER INSTALLATION IS FINISHED on page 4.
After finishing the construction of refrigerant piping, drain piping, and electric wiring, conduct test operation accordingly to protect the unit.

12-1 TEST OPERATION


Open the gas side stop valve.
Open the liquid side stop valve.
Electrify for 6 hours.
Set to cooling operation with the remote controller and start operation by pressing ON/OFF button (
).
Press INSPECTION/TEST OPERATION button (
) 4 times (2 times for wireless remote controller) and
operate at Test Operation mode for 3 minutes.
) to make sure the unit is in operation.
6. Press AIR FLOW DIRECTION ADJUST button (
) and operate normally.
7. Press INSPECTION/TEST OPERATION button (
8. Confirm function of unit according to the operation manual.
1.
2.
3.
4.
5.

256

Installation Manual

EDAU12-722

Indoor Units

PRECAUTIONS
1. Refer to 12-2 HOW TO DIAGNOSE FOR MALFUNCTION if the unit does not operate properly.
2. After completing the test run, press the INSPECTION/TEST OPERATION button once to put the unit in
inspection mode, and make sure the malfunction code is 00. (=normal)
If the code reads anything other than 00, refer to 12-2 HOW TO DIAGNOSE FOR MALFUNCTION.
NOTE
If a malfunction is preventing operation, refer to the malfunction diagnoses below.

12-2 HOW TO DIAGNOSE FOR MALFUNCTION


If the air conditioner does not operate normally after installing the air conditioner,
a malfunction shown in the table below may happen.
Remote control display

No display

88*
88 flashing

Malfunction
Power supply trouble or Open phase connection
Wrong wiring between indoor and outdoor unit
Indoor PC board faulty
Power supply PCB assy faulty
Wrong remote control connection wiring
Remote control faulty
Fuse faulty
Indoor PC board faulty
Wrong wiring between indoor and outdoor unit
Wrong wiring between indoor and outdoor unit

*After turning on the power, the maximun is 90 seconds, although it will only display 88. This is not a problem, and it will be set for 90 seconds.
Diagnose with the display on the liquid crystal display remote controller.
1. With the wired remote controller. (Note 1)
When the operation stops due to trouble, operation lamp flashes, and
and the malfunction code
are indicated on the liquid crystal display. In such a case, diagnose the fault contents by
referring to the table on the malfunction code list in case of group control, the unit No. is displayed
so that the indoor unit No. with the trouble can be recognized. (Note 2)
2. With the wireless remote controller.
(Refer also to the operation manual attached to the wireless remote controller)
NOTE
1.In case wired remote controller. Press the INSPECTION/TEST OPERATION button on remote controller,

starts flashing and changes the inspection mode.


2.Keep down the ON/OFF button for 5 seconds or longer in the inspection mode and the above trouble
history disappears, after the trouble code goes on and off twice, followed by the code 00(normal).
The display changes from the inspection mode to the normal mode.

Installation Manual

257

Indoor Units

EDAU12-722

12-3 Malfunction code


For places where the malfunction code is left blank, the
indication is not displayed. Though the
system continues operating, be sure to inspect the system and make repairs as necessary.
Depending on the type of indoor or outdoor unit, the malfunction code may or may not be displayed.
Code
A1
A3
A5
A6
AH
AJ
C4
C5
C9
CJ
E0
E1
E3
E4
E5
E6
E7
E8
E9
EA
F3
H3
H4
H6
H7
H8
H9
J3
J5
J6
J8
J9
L4
L5

258

Malfunction/Remarks
Indoor unit's PC board faulty
Drain water level abnormal
Freeze-up protector or stopped by high pressure control
Indoor fan motor overloaded, overcurrent or locked
Air cleaner faulty
Only the air cleaner does not function.
Type set improper
Capacity data is wrongly proset. Or there is nothing programmed in the data hold IC.
Sensor (R2T) for heat exchanger temperature is fault
Sensor (R3T) for heat exchanger temperature is fault
Sensor for suction air temperature is fault
Sensor for remote controller is fault
The remote controller thermistor does not function, but the system thermo run is possible.
Action of safety device (outdoor unit)
Outdoor unit's PC board faulty
High pressure abnormal (outdoor unit)
Low pressure abnormal (outdoor unit)
Compressor motor lock malfunction
Compressor motor lock by over current (outdoor)
Outdoor fan motor lock malfunction
Outdoor fan instantaneous overcurrent malfunction
Input overcurrent (outdoor unit)
Electronic expansion valve faulty (outdoor unit)
Cooling/heating swich malfunction. (outdoor unit)
Discharge pipe temperature abnormal (outdoor unit)
High pressure switch faulty (outdoor unit)
Low pressure switch faulty (outdoor unit)
Faulty position defection sensor (outdoor unit)
Outdoor motor position signal malfunction
CT abnormality (outdoor unit)
Outdoor air thermistor faulty (outdoor unit)
Discharge pipe thermistor faulty (outdoor unit)
Suction pipe thermistor faulty (outdoor unit)
Heat exchanger thermistor faulty (outdoor unit)
Liquid piping thermistor malfunction (heating) (outdoor)
Gas piping thermistor malfunction (cooling) (outdoor)
Overheated heat-radiating fin (outdoor unit)
Inverter cooling defect.
Instantaneous overcurrent (outdoor unit)
Possible earth fault or short circuit in the compressor motor.

Installation Manual

EDAU12-722

Indoor Units

L8
L9
LC
P1
P3
P4
PJ
U0
U1
U2

U4
UF

U5
U8
UA
UC

Electric thermal (outdoor unit)


Possible electrical overload in the compressor or cut line in the compressor motor.
Stall prevention (outdoor unit)
Compressor possibly locked.
Transmission malfunction between the outdoor control unit's inverters (outdoor unit)
Open-phase or main circuit low voltage (outdoor unit)
PC-board temperature sensor malfunction (outdoor unit)
Heat-radiating fin temperature sensor malfunction (outdoor unit)
Type set improper (outdoor unit)
Capacity data is wrongly proset. Or there is nothing programmed in the data hold IC.
Suction pipe temperature abnormal or refrigerant shortage.
Reverse phase
Peverse two phase of the L1, L2 and L3 leads.
Power source voltage malfunction (NOTE 3)
Includes the defect in 52C.
Transmission error (indoor unit - outdoor unit)
Incorrect wiring between indoor and outdoor units or malfunction of the PC board
mounted on the indoor and the outdoor units.
If UF is shown, the wiring between the indoor and outdoor unit is not properly wired.
Therefore, immediately disconnect the power supply and correct the wiring. (The compressor and the fan mounted on the outdoor unit may start operation independent of the
remote controller operation)
Transmission error (indoor unit - outdoor unit)
Transmission is improper between the indoor unit and the remote controller.
Malfunction in transmission between main and sub remote controls.
(Malfunction in sub remote control.)
Miss setting for multi system
Setting is wrong for selector switch of multi-system. (see switch SS2 on the main unit's
PC board) Incorrect combination with indoor unit and outdoor unit.
Central control address overlapping

3P083811-4P

Installation Manual

259

Outdoor Units

EDAU12-722

2. Outdoor Units
2.1

Safety Precautions

Safety Precautions
Read these Safety Precautions carefully to ensure correct installation.
This manual classifies the precautions into WARNING and CAUTION.
Be sure to follow all the precautions below: they are all important for ensuring safety.
WARNING

Failure to follow any of WARNING is likely to result in such grave consequences as death or serious injury.

CAUTION

Failure to follow any of CAUTION may result in grave consequences in some cases.

The following safety symbols are used throughout this manual:


Be sure to observe this instruction.

Be sure to establish an earth connection.

Never attempt.

After completing installation, test the unit to check for installation errors. Give the user adequate instructions
concerning the use and cleaning of the unit according to the Operation Manual.

WARNING
Installation should be left to the dealer or another professional. Improper installation may cause water leakage, electrical shock, or fire.
Install the air conditioner according to the instructions given in this manual. Incomplete installation may cause water leakage, electrical shock, or fire.
Be sure to use the supplied or specified installation parts. Use of other parts may cause the unit to come to lose, water leakage, electrical shock, or fire.
Install the air conditioner on a solid base that can support the weight of the unit. An inadequate base or incomplete installation may cause injury in the event the unit falls off the base.
Electrical work should be carried out in accordance with the installation manual and the national electrical wiring
rules or code of practice. Insufficient capacity or incomplete electrical work may cause electrical shock or fire.
Be sure to use a dedicated power circuit. Never use a power supply shared by another appliance.
For wiring, use a cable length enough to cover the entire distance with no connection.
Do not use an extension cord. Do not put other loads on the power supply, use a dedicated power circuit. (Failure to do so may cause abnormal heat, electric shock or fire.)

Use the specified types of wires for electrical connections between the indoor and outdoor units.
Firmly clamp the interconnecting wires so their terminals receive no external stresses. Incomplete connections or clamping may cause terminal overheating or fire.

After connecting interconnecting and supply wiring be sure to shape the cables so that they do not put undue force on the electrical covers or panels.
Install covers over the wires. Incomplete cover installation may cause terminal overheating, electrical shock, or fire.

When installing or relocating the system, be sure to keep the refrigerant circuit free from substances other than the specified
refrigerant (R410A), such as air. (Any presence of air or other foreign substance in the refrigerant circuit causes an abnormal pressure rise or rupture, resulting in injury.)
If any refrigerant has leaked out during the installation work, ventilate the room.
(The refrigerant produces a toxic gas if exposed to flames.)

After all installation is complete, check to make sure that no refrigerant is leaking out.
(The refrigerant produces a toxic gas if exposed to flames.)

During pump-down, stop the compressor before removing the refrigerant piping. If the compressor is still running and the stop valve is open during
pump-down, air will be sucked in when the refrigerant piping is removed, causing abnormal pressure in the freezer cycle which will lead to breakage and even injury.

During installation, attach the refrigerant piping securely before running the compressor. If the compressor is not attached and the stop valve is
open during pump-down, air will be sucked in when the compressor is run, causing abnormal pressure in the freezer cycle which will lead to breakage and even injury.

Be sure to establish an earth. Do not earth the unit to a utility pipe, arrester, or telephone earth.
Incomplete earth may cause electrical shock, or fire. A high surge current from lightning or other sources may cause damage to the air conditioner.

Be sure to install an earth leakage breaker. Failure to install an earth leakage breaker may result in electric shocks, or fire.

CAUTION
Do not install the air conditioner in a place where there is danger of exposure to inflammable gas leakage.
If the gas leaks and builds up around the unit, it may catch fire.

Establish drain piping according to the instructions of this manual. Inadequate piping may cause flooding.
Tighten the flare nut according to the specified method such as with a torque wrench.
If the flare nut is tightened too hard, the flare nut may crack after a long time and cause refrigerant leakage.

Make sure to provide for adequate measures in order to prevent that the outdoor unit be used as a shelter by small animals.
Small animals making contact with electrical parts can cause malfunctions, smoke or fire. Please instruct the customer to keep the area around the unit clean.

260

Installation Manual

EDAU12-722

2.2

Outdoor Units

3MXS52EVMA

Accessories
Accessories supplied with the outdoor unit:
(B) Drain plug

(A) Installation Manual

3
There is on the bottom packing case.
(C) Reducer assy

(D) Screw bag


(For fixing electrical wire anchor bands)

There is on the bottom packing case.


(3MXS52, 3MKS58)

There is on the bottom packing case.

Precautions for Selecting the Location


OUTDOOR UNIT
1) Choose a place solid enough to bear the weight and vibration of the unit, where the operation noise will not be amplified.
2) Choose a location where the hot air discharged from the unit or the operation noise will not cause a nuisance to the
neighbors of the user.
3) Avoid places near a bedroom and the like, so that the operation noise will cause no trouble.
4) There must be sufficient spaces for carrying the unit into and out of the site.
5) There must be sufficient space for air passage and no obstructions around the air inlet and the air outlet.
6) The site must be free from the possibility of flammable gas leakage in a nearby place.
7) Install units, power cords and inter-unit cables at least 3 meter away from television and radio sets. This is to prevent
interference to images and sounds. (Noises may be heard even if they are more than 3 meter away depending on radio
wave conditions.)
8) In coastal areas or other places with salty atmosphere of sulfate gas, corrosion may shorten the life of the air conditioner.
9) Since drain flows out of the outdoor unit, do not place under the unit anything which must be kept away from moisture.

NOTE
Cannot be installed hanging from ceiling or stacked.

CAUTION
When operating the air conditioner in a low outdoor ambient
temperature, be sure to follow the instructions described below.
1) To prevent exposure to wind, install the outdoor unit with its
suction side facing the wall.
2) Never install the outdoor unit at a site where the suction side
may be exposed directly to wind.
3) To prevent exposure to wind, it is recommended to install a
baffle plate on the air discharge side of the outdoor unit.
4) In heavy snowfall areas, select an installation site where the
snow will not affect the unit.

Installation Manual

Construct a large canopy.


Construct a pedestal.

Install the unit high enough off the


ground to prevent burying in snow.

261

Outdoor Units

EDAU12-722

Indoor/Outdoor Unit Installation Drawings


For installation of the indoor units, refer to the installation manual which was provided with the units.
(The diagram shows a wall-mounted indoor unit.)

CAUTION
1) Do not connect the embedded branch piping and the outdoor unit when only carrying out piping work without
connecting the indoor unit in order to add another indoor unit later.
Make sure no dirt or moisture gets into either side of the embedded branch piping.
See 7 Refrigerant Piping Work in Refrigerant Piping Work (3) for details.
2) Heat pump type: It is impossible to connect the indoor unit for one room only. Be sure to connect at least 2 rooms.
Cooling only type: It is possible to connect the indoor unit for one room only.

Cut thermal insulation


pipe to an appropriate
length and wrap it with
tape, making sure that no
gap is left in the insulation
pipes cut line.
Caulk
pipe hole
gap
with putty.
Wrap the insulation
pipe with the finishing
tape from bottom to top.
Allow 30cm of work
space below the
ceiling surface.
Allow space for piping
and electrical servicing.
25cm from wa

ll

If there is the danger of the unit falling


or overturning, fix the unit with
foundation bolts, or with wire or other
means.
If the location does not have good
drainage, place the unit on a level
mounting base (or a plastic pedestal).
Install the outdoor unit in a level
position. Failure to do so may result in
water leakage or accumulation.

Stop valve cover


m
3c

(Foot
bo

58cm
lt-hole
centre

le
ho

3
olt
t b s)
oo re
(F ent
c

s)

Also insulate the connection on the outdoor unit.


Level mounting base
(available separately)

Clamping material
Insulation tube
Tape

Service lid

Use tape or insulating material on all connections


to prevent air from getting in between the copper
piping and the insulation tube.
Be sure to do this if the outdoor unit is installed
above.

262

Installation Manual

EDAU12-722

Outdoor Units

Installation
Install the unit horizontally.
The unit may be installed directly on a concrete verandah or a solid place if drainage is good.
If the vibration may possibly be transmitted to the building, use a vibration-proof rubber (field supply).

Connections (Connection Port)

Install the indoor unit according to the table below, which shows the relationship between the class of indoor unit and the
corresponding port.
The total indoor unit class that can be connected to this unit:
Heat pump type: 3MXS52 Up to 9.0kW
Cooling only type: 3MKS50 Up to 9.5kW
3MKS58 Up to 10.0kW
Port

3MXS52

3MKS50

3MKS58
#

20 , 25 , 35

25 , 35

20 , 25 , 35

25 , 35

20 , 25 , 35 , 50

20 , 25 , 35 , 50
#

25 , 35

20 , 25 , 35 , 50

20 , 25 , 35 , 50

: Use a reducer to connect pipes.


: Use No. 2 and 4 reducers

: Use No. 5 and 6 reducers

: Use No. 1 and 3 reducers


Refer to How to Use Reducers for information on reducer numbers and their shapes.
#

Precautions on Installation

20

Check the strength and level of the installation ground so that the unit will not cause any operating vibration or noise after installed.
In accordance with the foundation drawing in fix the unit securely by means of the foundation bolts. (Prepare four sets of M8
or M10 foundation bolts, nuts and washers each which are available on the market.)
It is best to screw in the foundation bolts until their length are 20mm from the foundation surface.

Installation Manual

263

Outdoor Units

EDAU12-722

Outdoor Unit Installation Guidelines


Where a wall or other obstacle is in the path of outdoor units intake or exhaust airflow, follow the installation guidelines below.
For any of the below installation patterns, the wall height on the exhaust side should be 1200mm or less.

Wall facing one side

Walls facing two sides

More than 100

More than 350


More than 350
More
than 100

1200
or less
More than 50

More than 50
Top view

Side view

Walls facing three sides

More than 100


More than 50

More than 350


Top view

Unit: mm

Selecting a Location for Installation of the Indoor Units


The maximum allowable length of refrigerant piping, and the maximum allowable height difference between the outdoor and
indoor units, are listed below. (The shorter the refrigerant piping, the better the performance. Connect so that the piping is as
short as possible. Shortest allowable length per room is 3m.)
3MXS52, 3MKS50, 3MKS58

Outdoor unit capacity class


Piping to each indoor unit

25m max.

Total length of piping between all units

50m max.

Indoor Unit
Outdoor Unit
Level
difference:
15m max.

Level
difference: 7.5m
max.

(Heat pump
unit only)

If the outdoor unit is positioned higher than the indoor


units.

264

Level
difference:
15m max.
Level
difference:
7.5m max.

Outdoor Unit

(Heat pump Indoor Unit


unit only)
If the outdoor unit is positioned otherwise.
(If lower than one or more indoor units.)

Installation Manual

EDAU12-722

Outdoor Units

Refrigerant Piping Work (1)

1 Installing Outdoor Unit


When installing the outdoor unit, refer to Precautions for Selecting the Location and the Indoor/Outdoor Unit
Installation Drawings.
If drain work is necessary, follow the procedures below.

2 Drain Work
Use drain plug for drainage.
If the drain port is covered by a mounting base or floor surface, place additional foot bases of at least 30mm in height
under the outdoor units feet.
In cold areas, do not use a drain hose with the outdoor unit. (Otherwise, drain water may freeze, impairing heating
performance.)

Drain-water hole
Bottom frame
While pressing

Drain plug
Hose (available commercially,
inner dia. 16mm)

3 Refrigerant Piping
1) Align the centres of both flares and tighten the flare nuts 3 or 4 turns by hand. Then tighten them fully with the torque wrenches.
Use torque wrenches when tightening the flare nuts to prevent damage to the flare nuts and escaping gas.
Torque wrench

Coat here with refrigeration oil

Spanner

Piping union
Flare nut

Flare nut tightening torque


14.2-17.2N m
Flare nut for 6.4
(144-175kgf cm)
32.7-39.9N m
Flare nut for 9.5
(333-407kgf cm)
49.5-60.3N m
Flare nut for 12.7
(505-615kgf cm)
61.8-75.4N m
Flare nut for 15.9
(630-769kgf cm)

Valve cap tightening


torque
Liquid pipe
26.5-32.3N m
(270-330kgf cm)
Gas pipe
48.1-59.7N m
(490-610kgf cm)

Service port cap


tightening torque

10.8-14.7N m
(110-150kgf cm)

2) To prevent gas leakage, apply refrigeration oil on both inner and outer surfaces of the flare.
(Use refrigeration oil for R410A.)

Installation Manual

265

Outdoor Units

EDAU12-722

Refrigerant Piping Work (2)

4 Purging Air and Checking Gas Leakage


When piping work is completed, it is necessary to purge the air and check for gas leakage.

WARNING
1) Do not mix any substance other than the specified refrigerant (R410A) into the refrigeration cycle.
2) When refrigerant gas leaks occur, ventilate the room as soon and as much as possible.
3) R410A, as well as other refrigerants, should always be recovered and never be released directly into the environment.
4) Use a vacuum pump for R410A exclusively. Using the same vacuum pump for different refrigerants may damage the
vacuum pump or the unit.
If using additional refrigerant, perform air purging from the refrigerant pipes and indoor unit using a vacuum pump, then
charge additional refrigerant.
Use a hexagonal wrench (4mm) to operate the stop valve rod.
All refrigerant pipe joints should be tightened with a torque wrench at the specified tightening torque.
1) Connect projection side of charging hose (which comes from gauge manifold) to gas stop valves service port.
2) Fully open gauge manifolds low-pressure valve (Lo) and completely close its high-pressure valve (Hi).
(High-pressure valve subsequently requires no operation.)
3) Apply vacuum pumping. Check that the compound pressure gauge reads 0.1MPa (76cmHg).
Evacuation for at least 1 hour is recommended.
4) Close gauge manifolds low-pressure valve (Lo) and stop vacuum pump.
(Leave as is for 4-5 minutes and make sure the coupling meter needle does not go back.
If it does go back, this may indicate the presence of moisture or leaking from connecting parts. After inspecting all the
connection and loosening then retightening the nuts, repeat steps 2-4.)
5) Remove covers from liquid stop valve and gas stop valve.
6) Turn the liquid stop valves rod 90 degrees counterclockwise with a hexagonal wrench to open valve.
Close it after 5 seconds, and check for gas leakage.
Using soapy water, check for gas leakage from indoor units flare and outdoor units flare and valve rods.
After the check is complete, wipe all soapy water off.
7) Disconnect charging hose from gas stop valves service port, then fully open liquid and gas stop valves.
(Do not attempt to turn valve rod beyond its stop.)
8) Tighten valve caps and service port caps for the liquid and gas stop valves with a torque wrench at the specified
torques. See 3 Refrigerant Piping in Refrigerant Piping Work (1) for details.

5 Refilling the Refrigerant


Check the type of refrigerant to be used on the machine nameplate.
Precautions when adding R410A
Fill from the liquid pipe in liquid form.
It is a mixed refrigerant, so adding it in gas form may cause the refrigerant composition to change, preventing normal operation.
1) Before filling, check whether the cylinder has a siphon attached or not. (It should have something like liquid filling siphon
attached displayed on it.)
Filling a cylinder with an attached siphon
Stand the cylinder upright when filling.

Filling other cylinders


Turn the cylinder upside-down
when filling.

There is a siphon pipe inside, so the


cylinder need not be upside-down to
fill with liquid.

2) Be sure to use the R410A tools to ensure pressure and to prevent foreign objects entering.

266

Installation Manual

EDAU12-722

Outdoor Units

Refrigerant Piping Work (3)

6 Charging with Refrigerant


If the total length of piping for all rooms exceeds the figure listed below, additionally charge with 20g of refrigerant
(R410A) for each additional meter of piping.
Outdoor unit capacity class

3MXS52

Total length of piping for all rooms

30m

For cooling only


Cooling only models (3MKS50, 3MKS58) are chargeless. There is no need to charge with refrigerant.

CAUTION
Even though the stop valve is fully closed, the refrigerant may slowly leak out; do not leave the flare nut removed for a long
period of time.

7 Refrigerant Piping Work


Cautions on Pipe Handling

Wall

Be sure to
place a cap.
Rain

1) Protect the open end of the pipe against dust and moisture.
2) All pipe bends should be as gentle as possible. Use a pipe bender for
bending. (Bending radius should be 30 to 40mm or larger.)

If no flare cap is
available, cover
the flare mouth
with tape to keep
dirt or water out.

Selection of Copper and Heat Insulation Materials


When using commercial copper pipes and fittings, observe the following:
1) Insulation material: Polyethylene foam
Heat transfer rate: 0.041 to 0.052W/mK (0.035 to 0.045kcal/mhC)
Refrigerant gas pipes surface temperature reaches 110C max.
Choose heat insulation materials that will withstand this temperature.
2) Be sure to insulate both the gas and liquid piping and to provide insulation
dimensions as below.

Inter-unit wiring
Gas pipe

Pipe size

Pipe insulation

O.D.: 6.4mm / Thickness: 0.8mm


O.D.: 9.5mm, 12.7mm / Thickness: 0.8mm
O.D.: 15.9mm / Thickness: 1.0mm

I.D.: 8-10mm / Thickness: 10mm min.


I.D.: 12-15mm / Thickness: 13mm min.
I.D.: 16-20mm / Thickness: 13mm min.

Gas pipe
insulation

3) Use separate thermal insulation pipes for gas and liquid refrigerant pipes.

8 Flaring the Pipe End


1) Cut the pipe end with a pipe cutter.
2) Remove burrs with the cut surface facing downward
so that the chips do not enter the pipe.
3) Put the flare nut on the pipe.
4) Flare the pipe.
5) Check that the flaring is properly made.

Liquid pipe

Liquid pipe
insulation
Finishing tape

(Cut exactly at
right angles.)

Drain hose

Remove burrs

Flaring
Set exactly at the position shown below.
A

Die

Flare tool for R410A

Conventional flare tool

Clutch-type

Clutch-type (Rigid-type) Wing-nut type (Imperial-type)

0-0.5mm

1.0-1.5mm

1.5-2.0mm

Check
Flares inner
surface must
be flaw-free.

The pipe end must


be evenly flared in
a perfect circle.
Make sure that the
flare nut is fitted.

WARNING
1) Do not use mineral oil on flared part.
2) Prevent mineral oil from getting into the system as this would reduce the lifetime of the units.
3) Never use piping which has been used for previous installations. Only use parts which are delivered with the unit.
4) Do never install a drier to this R410A unit in order to guarantee its lifetime.
5) The drying material may dissolve and damage the system.
6) Incomplete flaring may cause refrigerant gas leakage.

Installation Manual

267

Outdoor Units

EDAU12-722

How to Use Reducers


No.1
15.9
12.7

No.2
12.7
9.5

Gasket (1)

No.3
15.9
12.7

No.4
12.7
9.5

No.5
15.9
9.5

Gasket (2)

No.6
15.9
9.5

Reduce and gasket

Use the reducers supplied with the unit as described below.


(1) Connecting a pipe of 12.7 to a gas pipe connection port for 15.9:

No. 1
Be sure to attach
the gasket.

Inter-unit piping
No. 3

Flare nut (for 15.9)

Connection port of outdoor unit

(2) Connecting a pipe of 9.5 to a gas pipe connection port for 15.9:

Flare nut (for 9.5)


No. 6

No. 5

Be sure to attach the gasket.

(3) Connecting a pipe of 9.5 to a gas pipe connection port for 12.7:

No. 2

No. 4

Flare nut (for 12.7)

Be sure to attach the gasket.

When using the reducer packing shown above, be careful not to overtighten
the nut, or the smaller pipe may be damaged (about 2/3 - 1 the normal
torque).
Apply a coat of refrigeration oil to the threaded connection port of the outdoor
unit where the flare nut comes in.
Use an appropriate wrench to avoid damaging the connection thread by
overtightening the flare nut.

268

Flare nut tightening torque


Flare nut for 9.5

32.7-39.9Nm
(333-407kgfcm)

Flare nut for 12.7

49.5-60.3Nm
(505-615kgfcm)

Flare nut for 15.9

61.8-75.4Nm
(630-769kgfcm)

Installation Manual

EDAU12-722

Outdoor Units

Pump Down Operation


In order to protect the environment, be sure to pump
down when relocating or disposing of the unit.

1) Remove the valve cap from liquid stop valve and gas stop
valve.
2) Carry out forced cooling operation. See Forced Operation.
3) After five to ten minutes, close the liquid stop valve with a
hexagonal wrench.
4) After two to three minutes, close the gas stop valve and
stop forced cooling operation.

Gas stop valve

Close
Hexagonal
wrench

Liquid stop
valve

Valve cap

Forced Operation
1) Turn the Operation Mode switch (SW2) to COOL. (Heat pump only)
2) Press the Forced Operation switch (SW1) to begin forced cooling. Press the Forced Operation switch (SW1) again to
stop forced cooling.
Forced operation also stops automatically after 15 minutes from when operation starts.

Service PC-board

Operation Mode
switch (SW2)

Installation Manual

Forced Operation
switch (SW1)

269

Outdoor Units

EDAU12-722

Wiring
WARNING
1) Do not use tapped wires, stranded wires (CAUTION (1)), extensioncords, or starbust connections, as they may cause
overheating, electrical shock, or fire.
2) Do not use locally purchased electrical parts inside the product. (Do not branch the power for the drain pump, etc.,
from the terminal block.) Doing so may cause electric shock or fire.
3) Be sure to install an earth leak detector. (One that can handle higher harmonics.)
(This unit uses an inverter, which means that it must be used an earth leak detector capable handling harmonics in
order to prevent malfunctioning of the earth leak detector itself.)
4) Use an all-pole disconnection type breaker with at least 3mm between the contact point gaps.
Do not turn ON the safety breaker until all work is
completed.
1) Strip the insulation from the wire (20mm).
2) Connect the connection wires between the indoor
and outdoor units so that the terminal numbers
match. Tighten the terminal screws securely. We
recommend a flathead screwdriver be used to
tighten the screws. The screws are packed with the
terminal board.
3) Be sure to match the symbols for wiring and piping.
4) Pull the wire and make sure that it does not
disconnect. Then fix the wire in place with the wire
retainer.

Room
A

Outdoor unit

Room
B

Room
C
Be sure to use the dedicated circuits.

Indoor unit

50Hz 220-240V
60Hz 220-230V

Earth leakage
circuit breaker

Safety breaker

To room C
H05VV

Room A
To room B
If the length of a connection wire is
10m or more, use 2.0mm wire.

CAUTION (1)
In case using stranded wires is unavoidable for some
reason, make sure to install the round crimp-style
terminals on the tip.

Place the round crimp-style terminals on the wires


up to the covered part and secure in place.
Round crimp-style
terminal
Stranded wire

<Ground terminal installation>


1) Use the following method when installing a single core wire.
Screw

Shape the wires so that


there is no lifting of the
service hatch or other
structural parts.

Flat washer

Use the specified


wires and
connect them
securely.

Wire
retainer

Be sure to clamp
the wire for
power source on
this location.

A single core wire

CAUTION (2)

Arrow view

2) Use the following method when installing the round


crimp-style terminal.
Screw

Flat washer

When connecting the connection wires to the


terminal board using a single core wire, be sure to
perform curling.
Problems with the work may cause heat and fires.

Round crimpstyle terminal

Screw

Flat washer
Round
crimp-style
terminal

Good
Screw
Flat washer
Round crimpstyle terminal

Wrong

Arrow view

270

Earth
This air conditioner must be earthed.
For earthing, follow the applicable local standard for
electrical installations.

Installation Manual

EDAU12-722

Outdoor Units

Priority Room Setting


To use Priority Room Setting, initial settings must be made when the
unit is installed. Explain the Priority Room Setting, as described below,
to the customer, and confirm whether or not the customer wants to use
Priority Room Setting.
Setting it in the guest and living rooms is convenient.

About the Priority Room Setting Function

Service PC-board

The indoor unit for which Priority Room Setting is applied takes priority in
the following cases.

1) Operation mode priority


The operation mode of the indoor unit which is set for Priority Room
Setting takes priority. If the set indoor unit is operating, all other indoor
units do not operate and enter standby mode, according to the
operation mode of the set indoor unit.

Priority Room
Setting switch (SW4)

2) Priority during powerful operation


If the indoor unit which is set for Priority Room Setting is operating at
powerful, the capabilities of other indoor units will be somewhat
reduced. Power supply gives priority to the indoor unit which is set for
Priority Room Setting.

3) Indoor or outdoor unit quiet operation priority


Setting the indoor unit to indoor or outdoor unit quiet operation will
make the outdoor unit run quiet operation.

Setting procedure
Slide the switch to the ON side for the switch that corresponds to the piping connected to the indoor unit to be set.
(In the figure below, it is room A.)
Once the settings are complete, reset the power.
Be sure to only set one room

Installation Manual

271

Outdoor Units

EDAU12-722

Night Quiet Mode Setting


If Night Quiet Mode is to be used, initial settings must be made when
the unit is installed.
Explain Night Quiet Mode, as described below, to the customer, and
confirm whether or not the customer wants to use Night Quiet Mode.

About Night Quiet Mode

Service PC-board

The Night Quiet Mode function reduces operating noise of the outdoor
unit at nighttime. This function is useful if the customer is worried about
the effects of the operating noise on the neighbors.
However, if Night Quiet Mode is running, cooling capacity will be saved.

Setting procedure
Remove the SW5 jumper switch.
Once the settings are complete, reset the power.
Night Quiet Mode
setting switch (SW5)

NOTE
Install the removed jumper switch as described below. This switch
will be needed to later disable this setting.

Jumper switch

After removing

COOL/ HEAT Mode Lock <S15> (Heat Pump Units Only)


Use the S15 connector to set the unit to only cool or heat.
Setting to only heat (H): short-circuit pins 1 and 3 of the connector <S15>
Setting to only cool (C): short-circuit pins 3 and 5 of the connector <S15>
The following specifications apply to the connector housing and pins.
JST products Housing: VHR-5N
Pin:
SVH-21T-1,1
Note that forced operation is also possible in COOL/HEAT mode.

COOL mode (C)


HEAT mode (H)

Arrow view

S10
S22

S15

S21

PCB
S20

272

Installation Manual

EDAU12-722

Outdoor Units

Test Run and Final Check (1)


Before starting the test run, measure the voltage at the primary side of the safety breaker.
Check that all liquid and gas stop valves are fully open.
Check that piping and wiring all match. The wiring error check can be conveniently used for underground wiring and other
wiring that cannot be directly checked.

Wiring Error Check

Service PC-board

This product is capable of automatic correction of wiring error.

Press the wiring error check switch on the outdoor unit service PCboard. However, the wiring error check switch will not function for
3 minutes after the safety breaker is turned on, or depending on the
outside air conditions. (See Note 2.) Approximately 15-20 minutes
after the switch is pressed, the errors in the connection wiring will be
corrected.

Wiring error
check switch
(SW3)

The service monitor LEDs indicate whether or not correction is


possible, as shown in the table below. For details about how to read
the LED display, refer to the service manual.
If self-correction is not possible, check the indoor unit wiring and
piping in the usual manner.

LED

Status

Message

All Flashing

Automatic correction impossible

Flashing One after another

Automatic correction completed

(One or more of LEDs 1 to 4 are ON) Abnormal stop [Note. 4]

Wiring correct example


Terminal block

The figure at left shows branch wiring.

From Room C
to the kitchen

From Room B
to the living room

From Room A
to the bedroom

Wiring error check


LED lighting sequence after a wiring correction.
Order of LED flashing: 2 1 3

NOTE
1) For two rooms, LED 3 and 4 are not displayed, and for three rooms, LED 4 is not displayed.
2) If the outside air temperature is 5 C or less , the wiring error check function will not operate.
3) After wiring error check operation is completed, LED indication will continue until ordinary operation starts.
This is normal.
4) Follow the product diagnosis procedures. (Check the nameplate on the underside of the stop valve.)

Installation Manual

273

Outdoor Units

EDAU12-722

Test Run and Final Check (2)


Test Run and Final Check
To test cooling, set for the lowest temperature. To test heating, set for the highest temperature. (Depending on the room
temperature, only heating or cooling (but not both) may be possible.)
After the unit is stopped, it will not start again (heating or cooling) for approximately 3 minutes.
During the test run, first check the operation of each unit individually. Then also check the simultaneous operation of all
indoor units.
Check both heating and cooling operation.
After running the unit for approximately 20 minutes, measure the temperatures at the indoor unit inlet and outlet. If the
measurements are above the values shown in the table below, then they are normal.

Temperature difference
between inlet and outlet

Cooling

Heating

Approx. 8C

Approx. 20C

(When running in one room)

During cooling operation, frost may form on the gas stop valve or other parts. This is normal.
Operate the indoor units in accordance with the included operation manual. Check that they operate normally.

Items to Check
Check item

Consequences of trouble

Are the indoor units installed securely?

Falling, vibration, noise

Has an inspection been made to check for gas leakage?

No cooling, no heating

Has complete thermal insulation been done (gas pipes, liquid


pipes, indoor portions of the drain hose extension)?

Water leakage

Is the drainage secure?

Water leakage

Are the ground wire connections secure?

Danger in the event of a ground fault

Are the electric wires connected correctly?

No cooling, no heating

Is the wiring in accordance with the specifications?

Operation failure, burning

Are the inlets/outlets of the indoor and outdoor units free of any
obstructions?
Are the stop valves open?

No cooling, no heating

Do the marks match (room A, room B) on the wiring and piping for
each indoor unit?

No cooling, no heating

Is the priority room setting set for 2 or more rooms?

The priority room setting will not function.

Check

ATTENTION
Have the customer actually operate the unit while looking at the manual included with the indoor unit. Instruct the
customer how to operate the unit correctly (particularly cleaning of the air filters, operation procedures, and temperature
adjustment).
Even when the air conditioner is not operating, it consumes some electric power. If the customer is not going to use the
unit soon after it is installed, turn OFF the breaker to avoid wasting electricity.
If additional refrigerant has been charged because of long piping, list the amount added on the nameplate on the
reverse side of the stop valve cover.

3P174484-4B

274

Installation Manual

EDAU12-722

2.3

Outdoor Units

3MXS68EVMA

Accessories
Accessories supplied with the outdoor unit:
(B) Drain plug

(A) Installation Manual

3
There is on the bottom packing case.
(C) Reducer assy

(D) Screw bag


(For fixing electrical wire anchor bands)

There is on the bottom packing case.

There is on the bottom packing case.

Precautions for Selecting the Location


OUTDOOR UNIT
1) Choose a place solid enough to bear the weight and vibration of the unit, where the operation noise will not be amplified.
2) Choose a location where the hot air discharged from the unit or the operation noise will not cause a nuisance to the
neighbors of the user.
3) Avoid places near a bedroom and the like, so that the operation noise will cause no trouble.
4) There must be sufficient spaces for carrying the unit into and out of the site.
5) There must be sufficient space for air passage and no obstructions around the air inlet and the air outlet.
6) The site must be free from the possibility of flammable gas leakage in a nearby place.
7) Install units, power cords and inter-unit cables at least 3 meter away from television and radio sets. This is to prevent
interference to images and sounds. (Noises may be heard even if they are more than 3 meter away depending on radio
wave conditions.)
8) In coastal areas or other places with salty atmosphere of sulfate gas, corrosion may shorten the life of the air conditioner.
9) Since drain flows out of the outdoor unit, do not place under the unit anything which must be kept away from moisture.

NOTE
Cannot be installed hanging from ceiling or stacked.

CAUTION
When operating the air conditioner in a low outdoor ambient
temperature, be sure to follow the instructions described below.
1) To prevent exposure to wind, install the outdoor unit with its
suction side facing the wall.
2) Never install the outdoor unit at a site where the suction side
may be exposed directly to wind.
3) To prevent exposure to wind, it is recommended to install a
baffle plate on the air discharge side of the outdoor unit.
4) In heavy snowfall areas, select an installation site where the
snow will not affect the unit.

Installation Manual

Construct a large canopy.


Construct a pedestal.

Install the unit high enough off the


ground to prevent burying in snow.

275

Outdoor Units

EDAU12-722

Indoor/Outdoor Unit Installation Drawings


For installation of the indoor units, refer to the installation manual which was provided with the units.
(The diagram shows a wall-mounted indoor unit.)

CAUTION
1) Do not connect the embedded branch piping and the outdoor unit when only carrying out piping work without
connecting the indoor unit in order to add another indoor unit later.
Make sure no dirt or moisture gets into either side of the embedded branch piping.
See 7 Refrigerant Piping Work in Refrigerant Piping Work (3) for details.
2) Heat pump type: It is impossible to connect the indoor unit for one room only. Be sure to connect at least 2 rooms.
Cooling only type: It is possible to connect the indoor unit for one room only.

Cut thermal insulation


pipe to an appropriate
length and wrap it with
tape, making sure that no
gap is left in the insulation
pipes cut line.
Caulk
pipe hole
gap
with putty.
Wrap the insulation
pipe with the finishing
tape from bottom to top.
Allow 30cm of work
space below the
ceiling surface.
Allow space for piping
and electrical servicing.
25cm from wa

ll

If there is the danger of the unit falling


or overturning, fix the unit with
foundation bolts, or with wire or other
means.
If the location does not have good
drainage, place the unit on a level
mounting base (or a plastic pedestal).
Install the outdoor unit in a level
position. Failure to do so may result in
water leakage or accumulation.

Stop valve cover


m
3c

(Foot
bo

58cm
lt-hole
centre

le
ho

3
olt
t b s)
oo re
(F ent
c

s)

Also insulate the connection on the outdoor unit.


Level mounting base
(available separately)

Clamping material
Insulation tube
Tape

Service lid

Use tape or insulating material on all connections


to prevent air from getting in between the copper
piping and the insulation tube.
Be sure to do this if the outdoor unit is installed
above.

276

Installation Manual

EDAU12-722

Outdoor Units

Installation
Install the unit horizontally.
The unit may be installed directly on a concrete verandah or a solid place if drainage is good.
If the vibration may possibly be transmitted to the building, use a vibration-proof rubber (field supply).

Connections (Connection Port)

Install the indoor unit according to the table below, which shows the relationship between the class of indoor unit and the
corresponding port.
The total indoor unit class that can be connected to this unit:
Heat pump type: 3MXS68 Up to 11.0kW
Cooling only type: 3MKS71 Up to 13.5kW
3MKS75 Up to 13.5kW
Port

3MXS68
#

A
B
C

3MKS71
#

3MKS75
#

20 , 25 , 35 , 50 , 60

25 , 35 , 50 , 60

20 , 25 , 35 , 50 , 60

20 , 25 , 35 , 50 , 60

25 , 35 , 50 , 60

20 , 25 , 35 , 50 , 60

20 , 25 , 35 , 50 , 60

25 , 35 , 50 , 60 , 71

20 , 25 , 35 , 50 , 60 , 71

: Use a reducer to connect pipes.


: Use No. 2 and 4 reducers

: Use No. 5 and 6 reducers

: Use No. 1 and 3 reducers


Refer to How to Use Reducers for information on reducer numbers and their shapes.
#

Precautions on Installation

20

Check the strength and level of the installation ground so that the unit will not cause any operating vibration or noise after installed.
In accordance with the foundation drawing in fix the unit securely by means of the foundation bolts. (Prepare four sets of M8
or M10 foundation bolts, nuts and washers each which are available on the market.)
It is best to screw in the foundation bolts until their length are 20mm from the foundation surface.

Installation Manual

277

Outdoor Units

EDAU12-722

Outdoor Unit Installation Guidelines


Where a wall or other obstacle is in the path of outdoor units intake or exhaust airflow, follow the installation guidelines below.
For any of the below installation patterns, the wall height on the exhaust side should be 1200mm or less.

Wall facing one side

Walls facing two sides

More than 100

More than 350


More than 350
More
than 100

1200
or less
More than 50

More than 50
Top view

Side view

Walls facing three sides

More than 100


More than 50

More than 350


Top view

Unit: mm

Selecting a Location for Installation of the Indoor Units


The maximum allowable length of refrigerant piping, and the maximum allowable height difference between the outdoor and
indoor units, are listed below. (The shorter the refrigerant piping, the better the performance. Connect so that the piping is as
short as possible. Shortest allowable length per room is 3m.)
3MXS68, 3MKS71, 3MKS75

Outdoor unit capacity class


Piping to each indoor unit

25m max.

Total length of piping between all units

60m max.

Indoor Unit
Outdoor Unit
Level
difference:
15m max.

Level
difference: 7.5m
max.

(Heat pump
unit only)

If the outdoor unit is positioned higher than the indoor


units.

278

Level
difference:
15m max.
Level
difference:
7.5m max.

Outdoor Unit

(Heat pump Indoor Unit


unit only)
If the outdoor unit is positioned otherwise.
(If lower than one or more indoor units.)

Installation Manual

EDAU12-722

Outdoor Units

Refrigerant Piping Work (1)

1 Installing Outdoor Unit


When installing the outdoor unit, refer to Precautions for Selecting the Location and the Indoor/Outdoor Unit
Installation Drawings.
If drain work is necessary, follow the procedures below.

2 Drain Work
Use drain plug for drainage.
If the drain port is covered by a mounting base or floor surface, place additional foot bases of at least 30mm in height
under the outdoor units feet.
In cold areas, do not use a drain hose with the outdoor unit. (Otherwise, drain water may freeze, impairing heating
performance.)

Drain-water hole
Bottom frame
While pressing

Drain plug
Hose (available commercially,
inner dia. 16mm)

3 Refrigerant Piping
1) Align the centres of both flares and tighten the flare nuts 3 or 4 turns by hand. Then tighten them fully with the torque wrenches.
Use torque wrenches when tightening the flare nuts to prevent damage to the flare nuts and escaping gas.
Torque wrench

Coat here with refrigeration oil

Spanner

Piping union
Flare nut

Flare nut tightening torque


14.2-17.2N m
Flare nut for 6.4
(144-175kgf cm)
32.7-39.9N m
Flare nut for 9.5
(333-407kgf cm)
49.5-60.3N m
Flare nut for 12.7
(505-615kgf cm)
61.8-75.4N m
Flare nut for 15.9
(630-769kgf cm)

Valve cap tightening


torque
Liquid pipe
26.5-32.3N m
(270-330kgf cm)
Gas pipe
48.1-59.7N m
(490-610kgf cm)

Service port cap


tightening torque

10.8-14.7N m
(110-150kgf cm)

2) To prevent gas leakage, apply refrigeration oil on both inner and outer surfaces of the flare.
(Use refrigeration oil for R410A.)

Installation Manual

279

Outdoor Units

EDAU12-722

Refrigerant Piping Work (2)

4 Purging Air and Checking Gas Leakage


When piping work is completed, it is necessary to purge the air and check for gas leakage.

WARNING
1) Do not mix any substance other than the specified refrigerant (R410A) into the refrigeration cycle.
2) When refrigerant gas leaks occur, ventilate the room as soon and as much as possible.
3) R410A, as well as other refrigerants, should always be recovered and never be released directly into the environment.
4) Use a vacuum pump for R410A exclusively. Using the same vacuum pump for different refrigerants may damage the
vacuum pump or the unit.
If using additional refrigerant, perform air purging from the refrigerant pipes and indoor unit using a vacuum pump, then
charge additional refrigerant.
Use a hexagonal wrench (4mm) to operate the stop valve rod.
All refrigerant pipe joints should be tightened with a torque wrench at the specified tightening torque.
1) Connect projection side of charging hose (which comes from gauge manifold) to gas stop valves service port.
2) Fully open gauge manifolds low-pressure valve (Lo) and completely close its high-pressure valve (Hi).
(High-pressure valve subsequently requires no operation.)
3) Apply vacuum pumping. Check that the compound pressure gauge reads 0.1MPa (76cmHg).
Evacuation for at least 1 hour is recommended.
4) Close gauge manifolds low-pressure valve (Lo) and stop vacuum pump.
(Leave as is for 4-5 minutes and make sure the coupling meter needle does not go back.
If it does go back, this may indicate the presence of moisture or leaking from connecting parts. After inspecting all the
connection and loosening then retightening the nuts, repeat steps 2-4.)
5) Remove covers from liquid stop valve and gas stop valve.
6) Turn the liquid stop valves rod 90 degrees counterclockwise with a hexagonal wrench to open valve.
Close it after 5 seconds, and check for gas leakage.
Using soapy water, check for gas leakage from indoor units flare and outdoor units flare and valve rods.
After the check is complete, wipe all soapy water off.
7) Disconnect charging hose from gas stop valves service port, then fully open liquid and gas stop valves.
(Do not attempt to turn valve rod beyond its stop.)
8) Tighten valve caps and service port caps for the liquid and gas stop valves with a torque wrench at the specified
torques. See 3 Refrigerant Piping in Refrigerant Piping Work (1) for details.

5 Refilling the Refrigerant


Check the type of refrigerant to be used on the machine nameplate.
Precautions when adding R410A
Fill from the liquid pipe in liquid form.
It is a mixed refrigerant, so adding it in gas form may cause the refrigerant composition to change, preventing normal operation.
1) Before filling, check whether the cylinder has a siphon attached or not. (It should have something like liquid filling siphon
attached displayed on it.)
Filling a cylinder with an attached siphon
Stand the cylinder upright when filling.

Filling other cylinders


Turn the cylinder upside-down
when filling.

There is a siphon pipe inside, so the


cylinder need not be upside-down to
fill with liquid.

2) Be sure to use the R410A tools to ensure pressure and to prevent foreign objects entering.

280

Installation Manual

EDAU12-722

Outdoor Units

Refrigerant Piping Work (3)

6 Charging with Refrigerant


If the total length of piping for all rooms exceeds the figure listed below, additionally charge with 20g of refrigerant
(R410A) for each additional meter of piping.
Outdoor unit capacity class

3MXS68

Total length of piping for all rooms

30m

For cooling only


Cooling only models (3MKS71, 3MKS75) are chargeless. There is no need to charge with refrigerant.

CAUTION
Even though the stop valve is fully closed, the refrigerant may slowly leak out; do not leave the flare nut removed for a long
period of time.

7 Refrigerant Piping Work


Cautions on Pipe Handling

Wall

Be sure to
place a cap.
Rain

1) Protect the open end of the pipe against dust and moisture.
2) All pipe bends should be as gentle as possible. Use a pipe bender for
bending. (Bending radius should be 30 to 40mm or larger.)

If no flare cap is
available, cover
the flare mouth
with tape to keep
dirt or water out.

Selection of Copper and Heat Insulation Materials


When using commercial copper pipes and fittings, observe the following:
1) Insulation material: Polyethylene foam
Heat transfer rate: 0.041 to 0.052W/mK (0.035 to 0.045kcal/mhC)
Refrigerant gas pipes surface temperature reaches 110C max.
Choose heat insulation materials that will withstand this temperature.
2) Be sure to insulate both the gas and liquid piping and to provide insulation
dimensions as below.

Inter-unit wiring
Gas pipe

Pipe size

Pipe insulation

O.D.: 6.4mm / Thickness: 0.8mm


O.D.: 9.5mm, 12.7mm / Thickness: 0.8mm
O.D.: 15.9mm / Thickness: 1.0mm

I.D.: 8-10mm / Thickness: 10mm min.


I.D.: 12-15mm / Thickness: 13mm min.
I.D.: 16-20mm / Thickness: 13mm min.

Gas pipe
insulation

3) Use separate thermal insulation pipes for gas and liquid refrigerant pipes.

8 Flaring the Pipe End


1) Cut the pipe end with a pipe cutter.
2) Remove burrs with the cut surface facing downward
so that the chips do not enter the pipe.
3) Put the flare nut on the pipe.
4) Flare the pipe.
5) Check that the flaring is properly made.

Liquid pipe

Liquid pipe
insulation
Finishing tape

(Cut exactly at
right angles.)

Drain hose

Remove burrs

Flaring
Set exactly at the position shown below.
A

Die

Flare tool for R410A

Conventional flare tool

Clutch-type

Clutch-type (Rigid-type) Wing-nut type (Imperial-type)

0-0.5mm

1.0-1.5mm

1.5-2.0mm

Check
Flares inner
surface must
be flaw-free.

The pipe end must


be evenly flared in
a perfect circle.
Make sure that the
flare nut is fitted.

WARNING
1) Do not use mineral oil on flared part.
2) Prevent mineral oil from getting into the system as this would reduce the lifetime of the units.
3) Never use piping which has been used for previous installations. Only use parts which are delivered with the unit.
4) Do never install a drier to this R410A unit in order to guarantee its lifetime.
5) The drying material may dissolve and damage the system.
6) Incomplete flaring may cause refrigerant gas leakage.

Installation Manual

281

Outdoor Units

EDAU12-722

How to Use Reducers


No.1
15.9
12.7

No.2
12.7
9.5

Gasket (1)

No.3
15.9
12.7

No.4
12.7
9.5

No.5
15.9
9.5

Gasket (2)

No.6
15.9
9.5

Reduce and gasket

Use the reducers supplied with the unit as described below.


(1) Connecting a pipe of 12.7 to a gas pipe connection port for 15.9:

No. 1
Be sure to attach
the gasket.

Inter-unit piping
No. 3

Flare nut (for 15.9)

Connection port of outdoor unit

(2) Connecting a pipe of 9.5 to a gas pipe connection port for 15.9:

Flare nut (for 9.5)


No. 6

No. 5

Be sure to attach the gasket.

(3) Connecting a pipe of 9.5 to a gas pipe connection port for 12.7:

No. 2

No. 4

Flare nut (for 12.7)

Be sure to attach the gasket.

When using the reducer packing shown above, be careful not to overtighten
the nut, or the smaller pipe may be damaged (about 2/3 - 1 the normal
torque).
Apply a coat of refrigeration oil to the threaded connection port of the outdoor
unit where the flare nut comes in.
Use an appropriate wrench to avoid damaging the connection thread by
overtightening the flare nut.

282

Flare nut tightening torque


Flare nut for 9.5

32.7-39.9Nm
(333-407kgfcm)

Flare nut for 12.7

49.5-60.3Nm
(505-615kgfcm)

Flare nut for 15.9

61.8-75.4Nm
(630-769kgfcm)

Installation Manual

EDAU12-722

Outdoor Units

Pump Down Operation


In order to protect the environment, be sure to pump
down when relocating or disposing of the unit.

1) Remove the valve cap from liquid stop valve and gas stop
valve.
2) Carry out forced cooling operation. See Forced Operation.
3) After five to ten minutes, close the liquid stop valve with a
hexagonal wrench.
4) After two to three minutes, close the gas stop valve and
stop forced cooling operation.

Gas stop valve

Close
Hexagonal
wrench

Liquid stop
valve

Valve cap

Forced Operation
1) Turn the Operation Mode switch (SW2) to COOL. (Heat pump only)
2) Press the Forced Operation switch (SW1) to begin forced cooling. Press the Forced Operation switch (SW1) again to
stop forced cooling.
Forced operation also stops automatically after 15 minutes from when operation starts.

Service PC-board

Operation Mode
switch (SW2)

Installation Manual

Forced Operation
switch (SW1)

283

Outdoor Units

EDAU12-722

Wiring
WARNING
1) Do not use tapped wires, stranded wires (CAUTION (1)), extensioncords, or starbust connections, as they may cause
overheating, electrical shock, or fire.
2) Do not use locally purchased electrical parts inside the product. (Do not branch the power for the drain pump, etc.,
from the terminal block.) Doing so may cause electric shock or fire.
3) Be sure to install an earth leak detector. (One that can handle higher harmonics.)
(This unit uses an inverter, which means that it must be used an earth leak detector capable handling harmonics in
order to prevent malfunctioning of the earth leak detector itself.)
4) Use an all-pole disconnection type breaker with at least 3mm between the contact point gaps.
Do not turn ON the safety breaker until all work is
completed.
1) Strip the insulation from the wire (20mm).
2) Connect the connection wires between the indoor
and outdoor units so that the terminal numbers
match. Tighten the terminal screws securely. We
recommend a flathead screwdriver be used to
tighten the screws. The screws are packed with the
terminal board.
3) Be sure to match the symbols for wiring and piping.
4) Pull the wire and make sure that it does not
disconnect. Then fix the wire in place with the wire
retainer.

Outdoor unit

Room
A

Be sure to use the dedicated circuits.

Room
B

Earth leakage
circuit breaker

Safety breaker

Room
C

50Hz 220-240V
60Hz 220-230V

Indoor unit
To room B
Room A
H05VV
To room C
If the length of a connection wire is
10m or more, use 2.0mm wire.

CAUTION (1)
In case using stranded wires is unavoidable for some
reason, make sure to install the round crimp-style
terminals on the tip.

Place the round crimp-style terminals on the wires


up to the covered part and secure in place.
Round crimp-style
terminal
Stranded wire

<Ground terminal installation>


1) Use the following method when installing a single core wire.
Screw

Shape the wires so that


there is no lifting of the
service hatch or other
structural parts.

Flat washer

Use the specified


wires and
connect them
securely.

Wire
retainer

Be sure to clamp
the wire for
power source on
this location.

A single core wire

CAUTION (2)

Arrow view

2) Use the following method when installing the round


crimp-style terminal.
Screw

Flat washer

When connecting the connection wires to the


terminal board using a single core wire, be sure to
perform curling.
Problems with the work may cause heat and fires.

Round crimpstyle terminal

Screw

Flat washer
Round
crimp-style
terminal

Good
Screw
Flat washer
Round crimpstyle terminal

Wrong

Arrow view

284

Earth
This air conditioner must be earthed.
For earthing, follow the applicable local standard for
electrical installations.

Installation Manual

EDAU12-722

Outdoor Units

Priority Room Setting


To use Priority Room Setting, initial settings must be made when the
unit is installed. Explain the Priority Room Setting, as described below,
to the customer, and confirm whether or not the customer wants to use
Priority Room Setting.
Setting it in the guest and living rooms is convenient.

About the Priority Room Setting Function

Service PC-board

The indoor unit for which Priority Room Setting is applied takes priority in
the following cases.

1) Operation mode priority


The operation mode of the indoor unit which is set for Priority Room
Setting takes priority. If the set indoor unit is operating, all other indoor
units do not operate and enter standby mode, according to the
operation mode of the set indoor unit.

Priority Room
Setting switch (SW4)

2) Priority during powerful operation


If the indoor unit which is set for Priority Room Setting is operating at
powerful, the capabilities of other indoor units will be somewhat
reduced. Power supply gives priority to the indoor unit which is set for
Priority Room Setting.

3) Indoor or outdoor unit quiet operation priority


Setting the indoor unit to indoor or outdoor unit quiet operation will
make the outdoor unit run quiet operation.

Setting procedure
Slide the switch to the ON side for the switch that corresponds to the piping connected to the indoor unit to be set.
(In the figure below, it is room A.)
Once the settings are complete, reset the power.
Be sure to only set one room

Installation Manual

285

Outdoor Units

EDAU12-722

Night Quiet Mode Setting


If Night Quiet Mode is to be used, initial settings must be made when
the unit is installed.
Explain Night Quiet Mode, as described below, to the customer, and
confirm whether or not the customer wants to use Night Quiet Mode.

About Night Quiet Mode

Service PC-board

The Night Quiet Mode function reduces operating noise of the outdoor
unit at nighttime. This function is useful if the customer is worried about
the effects of the operating noise on the neighbors.
However, if Night Quiet Mode is running, cooling capacity will be saved.

Setting procedure
Remove the SW5 jumper switch.
Once the settings are complete, reset the power.
Night Quiet Mode
setting switch (SW5)

NOTE
Install the removed jumper switch as described below. This switch
will be needed to later disable this setting.

Jumper switch

After removing

COOL/ HEAT Mode Lock <S15> (Heat Pump Units Only)


Use the S15 connector to set the unit to only cool or heat.
Setting to only heat (H): short-circuit pins 1 and 3 of the connector <S15>
Setting to only cool (C): short-circuit pins 3 and 5 of the connector <S15>
The following specifications apply to the connector housing and pins.
JST products Housing: VHR-5N
Pin:
SVH-21T-1,1
Note that forced operation is also possible in COOL/HEAT mode.

COOL mode (C)


HEAT mode (H)

Arrow view

S15
S22

S10

S21

PCB
S20

286

Installation Manual

EDAU12-722

Outdoor Units

Test Run and Final Check (1)


Before starting the test run, measure the voltage at the primary side of the safety breaker.
Check that all liquid and gas stop valves are fully open.
Check that piping and wiring all match. The wiring error check can be conveniently used for underground wiring and other
wiring that cannot be directly checked.

Wiring Error Check

Service PC-board

This product is capable of automatic correction of wiring error.


Press the wiring error check switch on the outdoor unit service PCboard. However, the wiring error check switch will not function for
3 minutes after the safety breaker is turned on, or depending on the
outside air conditions. (See Note 2.) Approximately 15-20 minutes
after the switch is pressed, the errors in the connection wiring will be
corrected.
The service monitor LEDs indicate whether or not correction is
possible, as shown in the table below. For details about how to read
the LED display, refer to the service manual.

3
Wiring error
check switch
(SW3)

If self-correction is not possible, check the indoor unit wiring and


piping in the usual manner.

LED

Status

Message

All Flashing

Automatic correction impossible

Flashing One after another

Automatic correction completed

(One or more of LEDs 1 to 4 are ON) Abnormal stop [Note. 4]

Wiring correct example


Terminal block

The figure at left shows branch wiring.

From Room B
to the living room

From Room A
to the bedroom

From Room C
to the kitchen

Wiring error check


LED lighting sequence after a wiring correction.
Order of LED flashing: 2 1 3

NOTE
1) For two rooms, LED 3 and 4 are not displayed, and for three rooms, LED 4 is not displayed.
2) If the outside air temperature is 5 C or less , the wiring error check function will not operate.
3) After wiring error check operation is completed, LED indication will continue until ordinary operation starts.
This is normal.
4) Follow the product diagnosis procedures. (Check the nameplate on the underside of the stop valve.)

Installation Manual

287

Outdoor Units

EDAU12-722

Test Run and Final Check (2)


Test Run and Final Check
To test cooling, set for the lowest temperature. To test heating, set for the highest temperature. (Depending on the room
temperature, only heating or cooling (but not both) may be possible.)
After the unit is stopped, it will not start again (heating or cooling) for approximately 3 minutes.
During the test run, first check the operation of each unit individually. Then also check the simultaneous operation of all
indoor units.
Check both heating and cooling operation.
After running the unit for approximately 20 minutes, measure the temperatures at the indoor unit inlet and outlet. If the
measurements are above the values shown in the table below, then they are normal.

Temperature difference
between inlet and outlet

Cooling

Heating

Approx. 8C

Approx. 20C

(When running in one room)

During cooling operation, frost may form on the gas stop valve or other parts. This is normal.
Operate the indoor units in accordance with the included operation manual. Check that they operate normally.

Items to Check
Check item

Consequences of trouble

Are the indoor units installed securely?

Falling, vibration, noise

Has an inspection been made to check for gas leakage?

No cooling, no heating

Has complete thermal insulation been done (gas pipes, liquid


pipes, indoor portions of the drain hose extension)?

Water leakage

Is the drainage secure?

Water leakage

Are the ground wire connections secure?

Danger in the event of a ground fault

Are the electric wires connected correctly?

No cooling, no heating

Is the wiring in accordance with the specifications?

Operation failure, burning

Are the inlets/outlets of the indoor and outdoor units free of any
obstructions?
Are the stop valves open?

No cooling, no heating

Do the marks match (room A, room B) on the wiring and piping for
each indoor unit?

No cooling, no heating

Is the priority room setting set for 2 or more rooms?

The priority room setting will not function.

Check

ATTENTION
Have the customer actually operate the unit while looking at the manual included with the indoor unit. Instruct the
customer how to operate the unit correctly (particularly cleaning of the air filters, operation procedures, and temperature
adjustment).
Even when the air conditioner is not operating, it consumes some electric power. If the customer is not going to use the
unit soon after it is installed, turn OFF the breaker to avoid wasting electricity.
If additional refrigerant has been charged because of long piping, list the amount added on the nameplate on the
reverse side of the stop valve cover.

3P174484-6A

288

Installation Manual

EDAU12-722

2.4

Outdoor Units

4MXS80EVMA

Accessories
Accessories supplied with the outdoor unit:
(B) Drain socket assy
(HEAT PUMP ONLY)

(A) Installation Manual

(C) Reducer assy

Precautions for Selecting the Location


OUTDOOR UNIT
1) Choose a place solid enough to bear the weight and vibration of the unit, where the operation noise will not be
amplified.
2) Choose a location where the hot air discharged from the unit or the operation noise will not cause a nuisance to the
neighbors of the user.
3) Avoid places near a bedroom and the like, so that the operation noise will cause no trouble.
4) There must be sufficient spaces for carrying the unit into and out of the site.
5) There must be sufficient space for air passage and no obstructions around the air inlet and the air outlet.
6) The site must be free from the possibility of flammable gas leakage in a nearby place.
7) Install units, power cords and inter-unit cables at least 3 meter away from television and radio sets. This is to
prevent interference to images and sounds. (Noises may be heard even if they are more than 3 meter away
depending on radio wave conditions.)
8) In coastal areas or other places with salty atmosphere of sulfate gas, corrosion may shorten the life of the air
conditioner.
9) Since drain flows out of the outdoor unit, do not place under the unit anything which must be kept away from
moisture.

NOTE
Cannot be installed hanging from ceiling or stacked.

CAUTION
When operating the air conditioner in a low outdoor ambient
temperature, be sure to follow the instructions described below.
1) To prevent exposure to wind, install the outdoor unit with its
suction side facing the wall.
2) Never install the outdoor unit at a site where the suction side
may be exposed directly to wind.
3) To prevent exposure to wind, it is recommended to install a
baffle plate on the air discharge side of the outdoor unit.
4) In heavy snowfall areas, select an installation site where the
snow will not affect the unit.

Installation Manual

Construct a large canopy.


Construct a pedestal.

Install the unit high enough off the


ground to prevent burying in snow.

289

Outdoor Units

EDAU12-722

Indoor/Outdoor Unit Installation Drawings


For installation of the indoor units, refer to the installation manual which was provided with the units.
(The diagram shows a wall-mounted indoor unit.)

CAUTION
1) Do not connect the embedded branch piping and the outdoor unit when only carrying out piping work without
connecting the indoor unit in order to add another indoor unit later.
Make sure no dirt or moisture gets into either side of the embedded branch piping.
See 7 Refrigerant Piping Work in Refrigerant Piping Work (3) for details.
2) Heat pump type: It is impossible to connect the indoor unit for one room only. Be sure to connect at least 2 rooms.
Cooling only type: It is possible to connect the indoor unit for one room only.

Cut thermal insulation


pipe to an appropriate
length and wrap it with
tape, making sure that no
gap is left in the insulation
pipes cut line.
Caulk
pipe hole
gap
with putty.
Wrap the insulation
pipe with the finishing
tape from bottom to top.
Allow 30cm of work
space below the
ceiling surface.
Allow space for piping
and electrical servicing.
25cm from wa
ll

If there is the danger of the unit falling


or overturning, fix the unit with
foundation bolts, or with wire or other
means.
If the location does not have good
drainage, place the unit on a level
mounting base (or a plastic pedestal).
Install the outdoor unit in a level
position. Failure to do so may result in
water leakage or accumulation.

Right side plate

cm

le

o
-h
olt
t b es)
o
o r
(F ent
c
35

(Foot
bo

lt-hole

62cm
centre
s

Also insulate the connection on the outdoor unit.


Level mounting base
(available separately)

Clamping material
Insulation tube
Tape

Service lid

Use tape or insulating material on all connections


to prevent air from getting in between the copper
piping and the insulation tube.
Be sure to do this if the outdoor unit is installed
above.

290

Installation Manual

EDAU12-722

Outdoor Units

Installation
Install the unit horizontally.
The unit may be installed directly on a concrete verandah or a solid place if drainage is good.
If the vibration may possibly be transmitted to the building, use a vibration-proof rubber (field supply).

Connections (connection port)

Install the indoor unit according to the table below, which shows the relationship between the class of indoor unit and the
corresponding port.
The total indoor unit class that can be connected to this unit:
Heat pump type:

4MXS80 Up to 14.5kW
4MXS100 Up to 15.6kW
3MXS90 Up to 15.6kW
Cooling only type: 4MKS80 Up to 15.6kW
4MKS90 Up to 15.6kW
4MKS100 Up to 15.6kW
3MKS90 Up to 15.6kW
3MXS90
3MKS90

Port

20 , 25 , 35 , 50
#

25 , 35

20 , 25 , 35

25 , 35 , 50 , 60

20 , 25 , 35 , 50 , 60

25 , 35 , 50 , 60 , 71

20 , 25 , 35 , 50 , 60 , 71

25 , 35 , 50 , 60 , 71

4MXS100
4MKS100

20 , 25 , 35 , 50 , 60 , 71
20 , 25 , 35 , 50 , 60 , 71

4MXS80
4MKS90

4MKS80

20 , 25 , 35 , 50 , 60 , 71

: Use a reducer to connect pipes.


: Use No. 2 and 4 reducers

: Use No. 5 and 6 reducers

: Use No. 1 and 3 reducers


: Use No. 7 reducer
: Use No. 8 reducer
Refer to How to Use Reducers for information on reducer numbers and their shapes.
#

Precautions on Installation

20

Check the strength and level of the installation ground so that the unit will not cause any operating vibration or noise after installed.
In accordance with the foundation drawing in fix the unit securely by means of the foundation bolts. (Prepare four sets of
M8 or M10 foundation bolts, nuts and washers each which are available on the market.)
It is best to screw in the foundation bolts until their length are 20mm from the foundation surface.

Installation Manual

291

Outdoor Units

EDAU12-722

Outdoor Unit Installation Guidelines


Where a wall or other obstacle is in the path of outdoor units intake or exhaust airflow, follow the installation guidelines
below.
For any of the below installation patterns, the wall height on the exhaust side should be 1200mm or less.

Wall facing one side

Walls facing two sides

More than 100

More than 350


More than 350
More
than 100
1200
or less
More than 50

More than 50
Top view

Side view

Walls facing three sides

More than 100


More than 350

More than 50

Top view

Unit: mm

Selecting a Location for Installation of the Indoor Units


The maximum allowable length of refrigerant piping, and the maximum allowable height difference between the
outdoor and indoor units, are listed below. (The shorter the refrigerant piping, the better the performance. Connect so
that the piping is as short as possible. Shortest allowable length per room is 3m.)
Outdoor unit capacity class

4MXS80, 3MXS90, 4MXS100, 4MKS80, 4MKS90, 3MKS90, 4MKS100

Piping to each indoor unit

25m max.

Total length of piping between all units

70m max.

Indoor Unit
Outdoor Unit
Level
difference:
15m max.

Level
difference:
7.5m max.

If the outdoor unit is positioned higher than the indoor


units.

292

Level
difference:
15m max.
Level
difference:
7.5m max.

Outdoor Unit
Indoor Unit

If the outdoor unit is positioned otherwise.


(If lower than one or more indoor units)

Installation Manual

EDAU12-722

Outdoor Units

Refrigerant Piping Work (1)

1 Installing Outdoor Unit


When installing the outdoor unit, refer to Precautions for Selecting the Location and the Indoor/Outdoor Unit
Installation Drawings.
If drain work is necessary, follow the procedures below.

2 Drain Work
Use drain plug for drainage.
If the drain port is covered by a mounting base or floor surface, place additional foot bases of at least 100mm in
height under the outdoor units feet.
In cold areas, do not use a drain hose with the outdoor unit. (Otherwise, drain water may freeze, impairing
heating performance.)
1. Insert drain receiver (C) onto drain socket (A) and drain cap (B) beyond 4
projections around drain socket and drain cap.
2. Insert drain socket and drain caps into their matching drain hole ; Drain socket (A)
into drain hole I and drain caps (B) into drain hole II and III. After insertion, turn
them about 40 clockwise.

II

(A) Drain socket

(Be sure not to insert them into wrong drain holes, or there
causes water leakage.)

I
III

(B) Drain cap

(C) Drain receiver

(View from bottom)

3. Connect vinyl hose on the market (internal diameter of 25mm) to drain socket (A).
(If the house is too long and hangs down, fix it carefully to prevent the kinks.)

NOTE
If the drain holes of the outdoor unit are covered with the mounting bracket or the floor, raise the unit to provide the
space of more than 100mm under the leg of the outdoor unit.

3 Refrigerant Piping
1) Align the centres of both flares and tighten the flare nuts 3 or 4 turns by hand. Then tighten them fully with the torque wrenches.
Use torque wrenches when tightening the flare nuts to prevent damage to the flare nuts and escaping gas.
Torque wrench

Coat here with refrigeration machine oil

Spanner

Piping union
Flare nut

Flare nut tightening torque


14.2-17.2N m
(144-175kgf cm)
32.7-39.9N m
Flare nut for 9.5
(333-407kgf cm)
49.5-60.3N m
Flare nut for 12.7
(505-615kgf cm)
61.8-75.4N m
Flare nut for 15.9
(630-769kgf cm)
Flare nut for 6.4

Valve cap tightening


torque
Liquid pipe
26.5-32.3N m
(270-330kgf cm)
Gas pipe
48.1-59.7N m
(490-610kgf cm)

Service port cap


tightening torque

10.8-14.7N m
(110-150kgf cm)

2) To prevent gas leakage, apply refrigeration machine oil on both inner and outer surfaces of the flare.
(Use refrigeration oil for R410A)

Installation Manual

293

Outdoor Units

EDAU12-722

Refrigerant Piping Work (2)

4 Purging Air and Checking Gas Leakage


When piping work is completed, it is necessary to purge the air and check for gas leakage.

WARNING
1) Do not mix any substance other than the specified refrigerant (R410A) into the refrigeration cycle.
2) When refrigerant gas leaks occur, ventilate the room as soon and as much as possible.
3) R410A, as well as other refrigerants, should always be recovered and never be released directly into the environment.
4) Use a vacuum pump for R410A exclusively. Using the same vacuum pump for different refrigerants may damage
the vacuum pump or the unit.

If using additional refrigerant, perform air purging from the refrigerant pipes and indoor unit using a vacuum pump, then
charge additional refrigerant.
Use a hexagonal wrench (4mm) to operate the shut-off valve rod.
All refrigerant pipe joints should be tightened with a torque wrench at the specified tightening torque.
1) Connect projection side (on which worm pin is pressed) of charging hose (which comes from gauge manifold) to
gas shut-off valves service port.
2) Fully open gauge manifolds low-pressure valve (Lo) and completely close its high-pressure valve (Hi).
(High-pressure valve subsequently requires no operation.)
3) Apply vacuum pumping. Check that the compound pressure gauge reads 0.1MPa (76cmHg).
Evacuation for at least 1 hour is recommended.
4) Close gauge manifolds low-pressure valve (Lo) and stop vacuum pump.
(Leave as is for 4-5 minutes and make sure the coupling meter needle does not go back.
If it does go back, this may indicate the presence of moisture or leaking from connecting parts. After inspecting all
the connection and loosening then retightening the nuts, repeat steps 2-4.)
5) Remove covers from liquid shut-off value and gas shut-off valve.
6) Turn the liquid shut-off valves rod 90 degrees counterclockwise with a hexagonal wrench to open valve.
Close it after 5 seconds, and check for gas leakage.
Using soapy water, check for gas leakage from indoor units flare and outdoor units flare and valve rods.
After the check is complete, wipe all soapy water off.
7) Disconnect charging hose from gas shut-off valves service port, then fully open liquid and gas shut-off valves.
(Do not attempt to turn valve rod beyond its stop.)
8) Tighten valve lids and service port caps for the liquid and gas shut-off valves with a torque wrench at the specified
torques. See 3 Refrigerant Piping in Refrigerant Piping Work (1) for details.

5 Refilling The Refrigerant


Check the type of refrigerant to be used on the machine nameplate.
Precautions when adding R410A
Fill from the liquid pipe in liquid form.
It is a mixed refrigerant, so adding it in gas form may cause the refrigerant composition to change, preventing normal operation.
1) Before filling, check whether the cylinder has a siphon attached or not. (It should have something like liquid filling
siphon attached displayed on it.)
Filling a cylinder with an attached siphon
Stand the cylinder upright when filling.

Filling other cylinders


Turn the cylinder upside-down
when filling.

There is a siphon pipe inside, so the


cylinder need not be upside-down to
fill with liquid.

2) Be sure to use the R410A tools to ensure pressure and to prevent foreign objects entering.

294

Installation Manual

EDAU12-722

Outdoor Units

Refrigerant Piping Work (3)

6 Charging with Refrigerant


If the total length of piping for all rooms exceeds the figure listed below, additionally charge with 20g of refrigerant
(R410A) for each additional meter of piping.
Outdoor unit capacity class

4MXS80, 3MXS90, 4MXS100

Total length of piping for all rooms

40m

For cooling only


Cooling only models (4MKS80, 3MKS90, 4MKS90, 4MKS100) are chargeless. There is no need to charge with
refrigerant.

CAUTION
Even though the shut-off valve is fully closed, the refrigerant may slowly leak out; do not leave the flare nut removed
for a long period of time.

7 Refrigerant Piping Work


Cautions on Pipe Handling

Wall

Be sure to
place a cap.
Rain

1) Protect the open end of the pipe against dust and moisture.
2) All pipe bends should be as gentle as possible. Use a pipe bender for
bending. (Bending radius should be 30 to 40mm or larger.)

If no flare cap is
available, cover
the flare mouth
with tape to keep
dirt or water out.

Selection of Copper and Heat Insulation materials


When using commercial copper pipes and fittings, observe the following:
1) Insulation material: Polyethylene foam
Heat transfer rate: 0.041 to 0.052W/mK (0.035 to 0.045kcal/mhC)
Refrigerant gas pipes surface temperature reaches 110C max.
Choose heat insulation materials that will withstand this temperature.
2) Be sure to insulate both the gas and liquid piping and to provide
insulation dimensions as below.

Inter-unit wiring
Gas pipe

Pipe size

Pipe insulation

O.D.: 6.4mm / Thickness: 0.8mm


O.D.: 9.5mm, 12.7mm / Thickness: 0.8mm
O.D.: 15.9mm / Thickness: 1.0mm

I.D.: 8 10mm / Thickness: 10mm min.


I.D.: 12 15mm / Thickness: 13mm min.
I.D.: 16 20mm / Thickness: 13mm min.

Gas pipe
insulation

3) Use separate thermal insulation pipes for gas and liquid refrigerant pipes.

8 Flaring the Pipe End


1) Cut the pipe end with a pipe cutter.
2) Remove burrs with the cut surface facing
downward so that the chips do not enter the pipe.
3) Put the flare nut on the pipe.
4) Flare the pipe.
5) Check that the flaring is properly made.

Liquid pipe

Liquid pipe
insulation
Finishing tape

(Cut exactly at
right angles.)

Drain hose

Remove burrs

Flaring
Set exactly at the position shown below.
A

Die

Flare tool for R410A

Conventional flare tool

Clutch-type

Clutch-type (Rigid-type) Wing-nut type (Imperial-type)

0 0.5mm

1.0 1.5mm

1.5 2.0mm

Check
Flares inner
surface must
be flaw-free.

The pipe end must


be evenly flared in
a perfect circle.
Make sure that the
flare nut is fitted.

WARNING
1) Do not use mineral oil on flared part.
2) Prevent mineral oil from getting into the system as this would reduce the lifetime of the units.
3) Never use piping which has been used for previous installations. Only use parts which are delivered with the unit.
4) Do never install a drier to this R410A unit in order to guarantee its lifetime.
5) The drying material may dissolve and damage the system.
6) Incomplete flaring may cause refrigerant gas leakage.

Installation Manual

295

Outdoor Units

EDAU12-722

How to Use Reducers


No.1
15.9
12.7

No.2
12.7
9.5

Gasket (1)

No.3
15.9
12.7

No.4
12.7
9.5

No.5
15.9
9.5

Gasket (2)

No.6
15.9
9.5

No.7
9.5
12.7

Reduce and gasket

No.8
12.7
15.9

Reduce

Use the reducers supplied with the unit as described below.


(1) Connecting a pipe of 12.7 to a gas pipe connection port for 15.9:

No. 1
Be sure to attach
the gasket.

Inter-unit piping
No. 3

Flare nut (for 15.9)

Connection port of outdoor unit

(2) Connecting a pipe of 9.5 to a gas pipe connection port for 15.9:

Flare nut (for 9.5)


No. 6

No. 5

Be sure to attach the gasket.

(3) Connecting a pipe of 9.5 to a gas pipe connection port for 12.7:

No. 4

No. 2

Flare nut (for 12.7)

Be sure to attach the gasket.

(4) Connecting a pipe of 12.7 to a gas pipe connection port for 9.5:

No. 7

Flare nut (for 12.7)

(5) Connecting a pipe of 15.9 to a gas pipe connection port for 12.7:

No. 8

Flare nut (for 15.9)

When using the reducer packing shown above, be careful not to


overtighten the nut, or the smaller pipe may be damaged. (about 2/3 - 1
the normal torque)
Apply a coat of refrigeration oil to the threaded connection port of the
outdoor unit where the flare nut comes in.
Use an appropriate wrench to avoid damaging the connection thread by
overtightening the flare nut.

296

Flare nut tightening torque


Flare nut for 9.5

32.739.9Nm
(333407kgfcm)

Flare nut for 12.7

49.560.3Nm
(505615kgfcm)

Flare nut for 15.9

61.875.4Nm
(630769kgfcm)

Installation Manual

EDAU12-722

Outdoor Units

Pump Down Operation


In order to protect the environment, be sure to pump
down when relocating or disposing of the unit.

1) Remove the valve lid from liquid shut-off valve and gas
shut-off valve.
2) Carry out forced cooling operation. See Forced
Operation.
3) After five to ten minutes, close the liquid shut-off valve
with a hexagonal wrench.
4) After two to three minutes, close the gas shut-off valve
and stop forced cooling operation.

Gas shut-off valve

Close
Hexagonal
wrench

3
Liquid shut-off
valve

Valve lid

Forced Operation
1) Turn the Operation Mode switch (SW2) to COOL. (Heat pump only)
2) Press the Forced Operation switch (SW1) to begin forced cooling. Press the Forced Operation switch (SW1) again to
stop forced cooling.
Forced operation also stops automatically after 15 minutes from when operation starts.

Service PC-board

Operation Mode
switch (SW2)

Forced Operation
switch (SW1)

For 4 Rooms

Installation Manual

297

Outdoor Units

EDAU12-722

Wiring
WARNING
1) Do not use tapped wires, stranded wires (CAUTION (1)), extensioncords, or starbust connections, as they may
cause overheating, electrical shock, or fire.
2) Do not use locally purchased electrical parts inside the product. (Do not branch the power for the drain pump,
etc., from the terminal block.) Doing so may cause electric shock or fire.
3) Be sure to install an earth leak detector. (One that can handle higher harmonics.)
(This unit uses an inverter, which means that it must be used an earth leak detector capable handling harmonics
in order to prevent malfunctioning of the earth leak detector itself.)
4) Use an all-pole disconnection type breaker with at least 3mm between the contact point gaps.

Do not turn ON the safety breaker until all work is


completed.
1) Strip the insulation from the wire (20mm).
2) Connect the connection wires between the indoor
and outdoor units so that the terminal numbers
match. Tighten the terminal screws securely. We
recommend a flathead screwdriver be used to
tighten the screws. The screws are packed with
the terminal board.
3) Be sure to match the symbols for wiring and piping.
4) Pull the wire and make sure that it does not
disconnect. Then fix the wire in place with the wire
retainer.

Room
A

Room
B

Room
C

Room
D

Outdoor unit

Be sure to use the dedicated circuits.


50Hz 220-240V
60Hz 220-230V

Earth leakage
circuit breaker

Safety breaker

To room D

Indoor unit

To room C
H05VV

Room A
To room B
If the length of a connection wire is
10m or more, use 2.0mm wire.

CAUTION (1)
Room A

Room B

Power supply

In case using stranded wires is unavoidable for some


reason, make sure to install the round crimp-style
terminals on the tip.

Room C

Room D

Place the round crimp-style terminals on the wires


up to the covered part and secure in place.
Round crimp-style
terminal
Stranded wire

<Ground terminal installation>


1) Use the following method when installing a single core wire.
Screw

Shape the wires so that


there is no lifting of the
service hatch or other
structural parts.

Wire
retainer

Be sure to clamp the wire for


power source on this location.

Flat washer
Use the specified wires and
connect them securely.

A single core wire

Wire
retainer

CAUTION (2)

Arrow view

2) Use the following method when installing the round


crimp-style terminal.
Screw

Flat washer

When connecting the connection wires to the


terminal board using a single core wire, be sure to
perform curling.
Problems with the work may cause heat and fires.

Round crimpstyle terminal

Screw

Flat washer
Round
crimp-style
terminal

Good
Screw
Flat washer
Round crimpstyle terminal

Wrong

Arrow view

298

Earth
This air conditioner must be earthed.
For earthing, follow the applicable local standard for
electrical installations.

Installation Manual

EDAU12-722

Outdoor Units

Priority Room Setting


To use Priority Room Setting, initial settings must be made when the
unit is installed. Explain the Priority Room Setting, as described below,
to the customer, and confirm whether or not the customer wants to use
Priority Room Setting.
Setting it in the guest and living rooms is convenient.

About the Priority Room Setting function

Service PC-board

The indoor unit for which Priority Room Setting is applied takes priority in
the following cases.

1) Operation mode priority

Priority Room
Setting switch (SW4)

The operation mode of the indoor unit which is set for Priority Room
Setting takes priority. If the set indoor unit is operating, all other indoor
units do not operate and enter standby mode, according to the
operation mode of the set indoor unit.

2) Priority during powerful operation


If the indoor unit which is set for Priority Room Setting is operating at
powerful, the capabilities of other indoor units will be somewhat
reduced. Power supply gives priority to the indoor unit which is set for
Priority Room Setting.

3) Indoor or outdoor unit silent operation priority

For 4 Rooms

Setting the indoor unit to indoor or outdoor unit silent operation will
make the outdoor unit run silent operation.

Setting procedure
Slide the switch to the ON side for the switch that corresponds to the piping connected to the indoor unit to be set.
(In the figure below, it is room A.)
Once the settings are complete, reset the power.
Be sure to only set one room

Installation Manual

299

Outdoor Units

EDAU12-722

Night Quiet Mode setting


If Night Quiet Mode is to be used, initial settings must be made when
the unit is installed.
Explain Night Quiet Mode, as described below, to the customer, and
confirm whether or not the customer wants to use Night Quiet Mode.

About Night Quiet Mode

Service PC-board

The Night Quiet Mode function reduces operating noise of the outdoor
unit at nighttime. This function is useful if the customer is worried about
the effects of the operating noise on the neighbors.
However, if Night Quiet Mode is running, cooling capacity will be saved.

Setting procedure
Remove the SW5 jumper switch.
Once the settings are complete, reset the power.
Night Quiet Mode
setting switch (SW5)

NOTE
Install the removed jumper switch as described below. This switch
will be needed to later disable this setting.
For 4 Rooms

Jumper switch

After removing

COOL/ HEAT mode lock <S15> (Heat Pump units only)


Use the S15 connector to set the unit to only cool or heat.
Setting to only heat (H): short-circuit pins 1 and 3 of the connector <S15>
Setting to only cool (C): short-circuit pins 3 and 5 of the connector <S15>
The following specifications apply to the connector housing and pins.
JST products Housing: VHR-5N
Pin:
SVH-21T-1,1
Note that forced operation is also possible in COOL/HEAT mode.

COOL mode (C)


HEAT mode (H)

Arrow view

S23 S15
S22

S10

S21
S20

300

Installation Manual

EDAU12-722

Outdoor Units

Test Run and Final Check (1)


Before starting the test run, measure the voltage at the primary side of the safety breaker.
Check that all liquid and gas shut-off valves are fully open.
Check that piping and wiring all match. The wiring error check can be conveniently used for underground wiring and
other wiring that cannot be directly checked.

Wiring Error Check

Service PC-board

This product is capable of automatic correction of wiring error.

Press the wiring error check switch on the outdoor unit service PCboard. However, the wiring error check switch will not function for
3 minutes after the safety breaker is turned on, or depending on the
outside air conditions (See Note 2.). Approximately 15 20 minutes
after the switch is pressed, the errors in the connection wiring will be
corrected.

Wiring error
check switch
(SW3)

The service monitor LEDs indicate whether or not correction is


possible, as shown in the table below. For details about how to read
the LED display, refer to the service manual.
If self-correction is not possible, check the indoor unit wiring and
piping in the usual manner.

LED

Status

For 4 Rooms

Message

All Flashing

Automatic correction impossible

Flashing One after another

Automatic correction completed

(One or more of LEDs 1 to 4 are ON) Abnormal stop [Note. 4]

Wiring correct example


Terminal block

The figure at left shows branch wiring.

From Room C
to the kitchen

From Room B
From Room D
From Room A
to the living room to the childrens room to the bedroom

Wiring error check


LED lighting sequence after a wiring correction.
Order of LED flashing: 2 1 3 4

NOTE
1) For two rooms, LED 3 and 4 are not displayed, and for three rooms, LED 4 is not displayed.
2) If the outside air temperature is 5 C or less , the wiring error check function will not operate.
3) After wiring error check operation is completed, LED indication will continue until ordinary operation starts.
This is normal.
4) Follow the product diagnosis procedures. (Details of product error diagnosis are listed on the back of the
right side plate .)

Installation Manual

301

Outdoor Units

EDAU12-722

Test Run and Final Check (2)


Test Run and Final Check
To test cooling, set for the lowest temperature. To test heating, set for the highest temperature. (Depending on the
room temperature, only heating or cooling (but not both) may be possible.)
After the unit is stopped, it will not start again (heating or cooling) for approximately 3 minutes.
During the test run, first check the operation of each unit individually. Then also check the simultaneous operation of all
indoor units.
Check both heating and cooling operation.
After running the unit for approximately 20 minutes, measure the temperatures at the indoor unit inlet and outlet. If the
measurements are above the values shown in the table below, then they are normal.

Temperature difference
between inlet and outlet

Cooling

Heating

Approx. 8C

Approx. 20C

(When running in one room)

During cooling operation, frost may form on the gas shut-off valve or other parts. This is normal.
Operate the indoor units in accordance with the included operation manual. Check that they operate normally.

Items to Check
Check item

Consequences of trouble

Are the indoor units installed securely?

Falling, vibration, noise

Has an inspection been made to check for gas leakage?

No cooling, no heating

Has complete thermal insulation been done (gas pipes, liquid


pipes, indoor portions of the drain hose extension)?

Water leakage

Is the drainage secure?

Water leakage

Are the ground wire connections secure?

Danger in the event of a ground fault

Are the electric wires connected correctly?

No cooling, no heating

Is the wiring in accordance with the specifications?

Operation failure, burning

Are the inlets/outlets of the indoor and outdoor units free of


any obstructions?
Are the shut-off valves open?

No cooling, no heating

Do the marks match (room A, room B) on the wiring and


piping for each indoor unit?

No cooling, no heating

Is the priority room setting set for 2 or more rooms?

The priority room setting will not function.

Check

ATTENTION
Have the customer actually operate the unit while looking at the manual included with the indoor unit. Instruct the
customer how to operate the unit correctly (particularly cleaning of the air filters, operation procedures, and
temperature adjustment).
Even when the air conditioner is not operating, it consumes some electric power. If the customer is not going to
use the unit soon after it is installed, turn OFF the breaker to avoid wasting electricity.
If additional refrigerant has been charged because of long piping, list the amount added on the nameplate on the
reverse side of the shut-off valve cover.

3P174484-1

302

Installation Manual

EDAU12-722

Part 4
Operation Manual
1. Instruction............................................................................................304
1.1 FTXS, CDXS, FDXS, FLXS Series ......................................................304
1.2 FVXS Series.........................................................................................363
1.3 FFQ Series ...........................................................................................393

Operation Manual

303

Instruction

EDAU12-722

1. Instruction
1.1

FTXS, CDXS, FDXS, FLXS Series

1.1.1

Manual Contents and Reference Page


Wall Mounted Type

Model Series

FTXS20D
FTXS25/35E

FTXS50/60/71F

Safety Precautions

305

305

Names of Parts

307

310

322

322

AUTO, DRY, COOL, HEAT, FAN


Operation 1

325

325

Read before Operation

Preparation before Operation


Operation

Adjusting the Air Flow Direction

327

329

POWERFUL Operation

333

333

OUTDOOR UNIT QUIET Operation


1

334

334

ECONO Operation

335

MOLD PROOF Operation

336

337

INTELLIGENT EYE Operation

339

341

TIMER Operation

343

343

Note for Multi System

345

345

347

350

360

360

3P194539-2
3P194539-3

3P194539-1

HOME LEAVE Operation

Care
Care and Cleaning
Trouble Shooting
Trouble Shooting
Drawing No.

Floor/Ceiling Suspended
Dual Type

Duct Connected Type

Model Series

FDXS25/35/50/60C

CDXS25/35E

FLXS25-60B

Safety Precautions

305

305

305

Names of Parts

313

316

319

322

322

322

AUTO, DRY, COOL, HEAT, FAN


Operation 1

325

325

325

Read before Operation

Preparation before Operation


Operation

Adjusting the Air Flow Direction

331

333

333

333

334

334

334

ECONO Operation

MOLD PROOF Operation

337

337

337

POWERFUL Operation

OUTDOOR UNIT QUIET Operation


1

HOME LEAVE Operation

INTELLIGENT EYE Operation

343

343

343

Note for Multi System

345

345

345

353

355

357

TIMER Operation
Care
Care and Cleaning
Trouble Shooting
Trouble Shooting
Drawing No.

360

360

360

3P196326-7

3P196326-6

3P194537-7

1 : Illustrations are for wall mounted type FTXS20D as representative.


2 : Illustrations are for wall mounted type FTXS50~71F as representative.

304

Operation Manual

EDAU12-722

1.1.2

Instruction

Safety Precautions

Safety precautions

Keep this manual where the operator can easily find them.
Read this manual attentively before starting up the unit.
For safety reason the operator must read the following cautions carefully.
This manual classifies precautions into WARNING and CAUTION. Be sure to follow all precautions below: they are all
important for ensuring safety.

WARNING

CAUTION

If you do not follow these instructions exactly, the unit may


cause property damage, personal injury or loss of life.

If you do not follow these instructions exactly, the unit may


cause minor or moderate property damage or personal injury.

Never do.

Be sure to follow the instructions.

Be sure to earth the air conditioner.

Never cause the air conditioner (including the remote


controller) to get wet.

Never touch the air conditioner (including the remote


controller) with a wet hand.

WARNING
In order to avoid fire, explosion or injury, do not operate the unit when harmful, among which flammable or
corrosive gases, are detected near the unit.
It is not good for health to expose your body to the air flow for a long time.
Do not put a finger, a rod or other objects into the air outlet or inlet. As the fan is rotating at a high speed, it will
cause injury.
Do not attempt to repair, relocate, modify or reinstall the air conditioner by yourself. Incorrect work will cause electric
shocks, fire etc.
For repairs and reinstallation, consult your Daikin dealer for advice and information.
The refrigerant used in the air conditioner is safe. Although leaks should not occur, if for some
reason any refrigerant happens to leak into the room, make sure it does not come in contact
with any flame as of gas heaters, kerosene heaters or gas range.
If the air conditioner is not cooling (heating) properly, the refrigerant may be leaking, so call your dealer.
When carrying out repairs accompanying adding refrigerant, check the content of the repairs with our service staff.
Do not attempt to install the air conditioner by your self. Incorrect work will result in water leakage, electric shocks or
fire. For installation, consult the dealer or a qualified technician.
In order to avoid electric shock, fire or injury, if you detect any abnormally such as smell of fire, stop the operation and
turn off the breaker. And call your dealer for instructions.

CAUTION
The air conditioner must be earthed. Incomplete earthing may result in electric shocks. Do not connect the
earth line to a gas pipe, water pipe, lightning rod, or a telephone earth line.
In order to avoid any quality deterioration, do not use the unit for cooling precision instruments, food, plants,
animals or works of art.
Never expose little children, plants or animals directly to the air flow.
Do not place appliances which produce open fire in places exposed to the air flow from the unit or under the
indoor unit. It may cause incomplete combustion or deformation of the unit due to the heat.
Do not block air inlets nor outlets. Impaired air flow may result in insufficient performance or trouble.

Operation Manual

305

Instruction

EDAU12-722

Do not stand or sit on the outdoor unit. Do not place any object on the unit to avoid injury, do not remove the fan guard.
Do not place anything under the indoor or outdoor unit that must be kept away from moisture. In certain conditions,
moisture in the air may condense and drip.
After a long use, check the unit stand and fittings for damage.
Do not touch the air inlet and aluminum fins of outdoor unit. It may cause injury.
The appliance is not intended for use by young children or infirm persons without supervision.
Young children should be supervised to ensure that they do not play with the appliance.
To avoid oxygen deficiency, ventilate the room sufficiently if equipment with burner is used together with the
air conditioner.
Before cleaning, be sure to stop the operation, turn the breaker off or pull out the supply cord.
Do not connect the air conditioner to a power supply different from the one as specified. It may cause trouble or fire.
Depending on the environment, an earth leakage breaker must be installed. Lack of an earth leakage breaker may
result in electric shocks.
Arrange the drain hose to ensure smooth drainage. Incomplete draining may cause wetting of the building, furniture
etc.
Do not operate the air conditioner with wet hands.

Do not wash the indoor unit with excessive water, only use a slightly wet cloth.
Do not place things such as vessels containing water or anything else on top of the unit. Water may penetrate into the unit and degrade electrical insulations, resulting in an electric shock.

Installation site.
To install the air conditioner in the following types of environments, consult the dealer.
Places with an oily ambient or where steam or soot occurs.
Salty environment such as coastal areas.
Places where sulfide gas occurs such as hot springs.
Places where snow may block the outdoor unit.
The drain from the outdoor unit must be discharged to a place of good drainage.

Consider nuisance to your neighbours from noises.


For installation, choose a place as described below.
A place solid enough to bear the weight of the unit which does not amplify the operation noise or vibration.
A place from where the air discharged from the outdoor unit or the operation noise will not annoy
your neighbours.

Electrical work.
For power supply, be sure to use a separate power circuit dedicated to the air conditioner.

System relocation.
Relocating the air conditioner requires specialized knowledge and skills. Please consult the dealer if relocation is necessary for moving or remodeling.

306

Operation Manual

EDAU12-722

1.1.3

Instruction

Names of Parts

FTXS 20 D, FTXS 25/35 E

Names of parts
Indoor Unit
1

4
5
7

11

10

8
16

14
13

15
ON/OFF

Operation Manual

12

307

Instruction

EDAU12-722

Outdoor Unit
17

22
19
20

18

21

Indoor Unit
1. Air filter
2. Titanium Apatite Photocatalytic
Air-Purifying Filter:
These filters are attached to the inside of the air
filters.

12. Indoor Unit ON/OFF switch:


Push this switch once to start operation.
Push once again to stop it.
The operation mode refers to the following
table.

3. Air inlet
4. Front panel

FTK
FTX

5. Panel tab
6. Room temperature sensor:
It senses the air temperature around the unit.
7. INTELLIGENT EYE sensor:
It detects the movements of people and automatically switches between normal operation
and energy saving operation.
8. Display
9. Air outlet
10. Flaps (horizontal blades)
11. Louvers (vertical blades):
The louvers are inside of the air outlet.

Temperature
setting
COOL
22C
AUTO
25C
Mode

Air flow
rate
AUTO
AUTO

This switch is useful when the remote controller


is missing.
13. Operation lamp (green)
14. TIMER lamp (yellow)
15. INTELLIGENT EYE lamp (green)
16. Signal receiver:
It receives signals from the remote controller.
When the unit receives a signal, you will hear a
short beep.
Operation start .............beep-beep
Settings changed..........beep
Operation stop ..............beeeeep

Outdoor Unit
17. Air inlet: (Back and side)
18. Air outlet
19. Refrigerant piping and inter-unit cable
20. Drain hose

21. Earth terminal:


It is inside of this cover.
22. Outside air temperature sensor:
It senses the ambient temperature around the
unit.

Appearance of the outdoor unit may differ from some models.

308

Operation Manual

EDAU12-722

Instruction

Remote Controller
1

ECONO

ON/OFF

3
TEMP

POWERFUL

MODE

8
13

FAN
SWING
MOLD PROOF SENSOR

ON

CANCEL

9
10
12
11
16

OFF
TIMER

18
17

15
14

<ARC433A46, A47>
1. Signal transmitter:
It sends signals to the indoor unit.
2. Display:
It displays the current settings.
(In this illustration, each section is shown
with all its displays ON for the purpose of
explanation.)
3. ECONO button:
ECONO operation
4. POWERFUL button:
POWERFUL operation
5. TEMPERATURE adjustment buttons:
It changes the temperature setting.
6. ON/OFF button:
Press this button once to start operation.
Press once again to stop it.
7. MODE selector button:
It selects the operation mode.
(AUTO/DRY/COOL/HEAT/FAN)

Operation Manual

8. QUIET button: OUTDOOR UNIT QUIET


operation
9. FAN setting button:
It selects the air flow rate setting.
10. SWING button
11. MOLD PROOF button:
MOLD PROOF operation
12. SENSOR button: INTELLIGENT EYE
operation
13. ON TIMER button
14. OFF TIMER button
15. TIMER Setting button:
It changes the time setting.
16. TIMER CANCEL button:
It cancels the timer setting.
17. CLOCK button
18. RESET button:
Restart the unit if it freezes.
Use a thin object to push.

309

Instruction

EDAU12-722

FTXS 50/60/71 F

Names of parts
Indoor Unit

3
2

5
6
10

11

7
8

12

16

13
15
14

310

Operation Manual

EDAU12-722

Instruction

Outdoor Unit
50/60 class

71/80/90 class

17

17
19

19

20
18
18

21

21

20

Indoor Unit
1. Air filter
2. Titanium Apatite Photocatalytic
Air-Purifying Filter
3. Air inlet
4. Front panel
5. Panel tab

14. HOME LEAVE lamp (red):


Lights up when you use HOME LEAVE
Operation.
15. Indoor Unit ON/OFF switch:
Push this switch once to start operation.
Push once again to stop it.
The operation mode refer to the following table.

6. INTELLIGENT EYE sensor:


It detects the movements of people and
automatically switches between normal operation
and energy saving operation.

Temperature
setting
FTKS COOL
22C
25C
FTXS AUTO
Mode

7. Room temperature sensor:


It senses the air temperature around the unit.
8. Display
9. Air outlet
10. Flap (horizontal blade)
11. Louvers (vertical blades):
The Louvers are inside of the air outlet.
12. Operation lamp (green)
13. TIMER lamp (yellow)

Air flow
rate
AUTO
AUTO

This switch is useful when the remote controller


is missing.
16. Signal receiver:
It receives signals from the remote controller.
When the unit receives a signal, you will hear a
short beep.
Operation start .............beep-beep
Settings changed..........beep
Operation stop ..............beeeeep

Outdoor Unit
17. Air inlet: (Back and side)

20. Drain hose

18. Air outlet

21. Earth terminal:


It is inside of this cover.

19. Refrigerant piping and inter-unit cable

Appearance of the outdoor unit may differ from some models.

Operation Manual

311

Instruction

EDAU12-722

Remote Controller
1

5
3
6

9
11

7
QUIET

8
13

ON

CANCEL

12
10
16

OFF
TIMER

18
17

15
14

< ARC433B70, B71 >


1. Signal transmitter:
It sends signals to the indoor unit.
2. Display:
It displays the current settings.
(In this illustration, each section is shown
with all its displays ON for the purpose of
explanation.)
3. HOME LEAVE button:
HOME LEAVE operation
4. POWERFUL button:
POWERFUL operation
5. TEMPERATURE adjustment buttons:
It changes the temperature setting.
6. ON/OFF button:
Press this button once to start operation.
Press once again to stop it.
7. MODE selector button:
It selects the operation mode.
(AUTO/DRY/COOL/HEAT/FAN)

312

8. QUIET button: OUTDOOR UNIT QUIET


operation
9. FAN setting button:
It selects the air flow rate setting.
10. SENSOR button: INTELLIGENT EYE
operation
11. SWING button:
Flap (Horizontal blade)
12. SWING button:
Louver (Vertical blades)
13. ON TIMER button:
14. OFF TIMER button:
15. TIMER Setting button:
It changes the time setting.
16. TIMER CANCEL button:
It cancels the timer setting.
17. CLOCK button:
18. RESET button:
Restart the unit if it freezes.
Use a thin object to push.

Operation Manual

EDAU12-722

Instruction

FDXS 25/35/50/60 C

Names of parts
Indoor Unit
1

3
6
8
7

9
10

Operation Manual

313

Instruction

EDAU12-722

Outdoor Unit
11
12
13

15

14

Indoor Unit
1. Air outlet
2. Air outlet grille: (Field supply)
Appearance of the Air outlet grille and Air inlet
grille may differ with some models.
3. Display, Control panel

10. Indoor Unit ON/OFF switch:


Push this switch once to start operation.
Push once again to stop it.
This switch is useful when the remote controller
is missing.

4. Suction grille: (Option)


Appearance of the suction grille and Air inlet
grille may differ with some models.

The operation mode refers to the following table.

5. Air inlet

CDKS
C(F)DXS

6. Room temperature sensor:


It senses the air temperature around the unit.

Mode
COOL
AUTO

Temperature
Air flow rate
setting
22C
AUTO
25C
AUTO

7. Operation lamp (green)


8. TIMER lamp (yellow)
9. HOME LEAVE lamp (red):
Lights up when you use HOME LEAVE
operation.

Outdoor Unit
11. Air inlet: (Back and side)
12. Refrigerant piping and inter-unit cable

14. Earth terminal:


It is inside of this cover.

13. Drain hose

15. Air outlet

Appearance of the outdoor unit may differ from some models.

314

Operation Manual

EDAU12-722

Instruction

Remote Controller
1

3
6

9
7
8
10

13
15
14

12
11

ARC433B69, B76
1. Signal transmitter:
It sends signals to the indoor unit.
2. Display:
It displays the current settings.
(In this illustration, each section is shown
with all its displays ON for the purpose of
explanation.)
3. HOME LEAVE button:
HOME LEAVE operation
4. POWERFUL button:
POWERFUL operation
5. TEMPERATURE adjustment buttons:
It changes the temperature setting.
6. ON/OFF button:
Press this button once to start operation.
Press once again to stop it.

Operation Manual

7. MODE selector button:


It selects the operation mode.
(AUTO/DRY/COOL/HEAT/FAN)
8. QUIET button: OUTDOOR UNIT
QUIET operation
9. FAN setting button:
It selects the air flow rate setting.
10. ON TIMER button
11. OFF TIMER button
12. TIMER Setting button:
It changes the time setting.
13. TIMER CANCEL button:
It cancels the timer setting.
14. CLOCK button
15. RESET button:
Restart the unit if it freezes.
Use a thin object to push.

315

Instruction

EDAU12-722

CDXS 25/35 E

Names of parts
Indoor Unit
1

3
6
8
7

316

9
10

Operation Manual

EDAU12-722

Instruction

Outdoor Unit
11
12
13
15
14

Indoor Unit

1. Air outlet
2. Air outlet grille: (Field supply)
Appearance of the Air outlet grille and Air inlet
grille may differ with some models.
3. Display, Control panel

10. Indoor Unit ON/OFF switch:


Push this switch once to start operation.
Push once again to stop it.
This switch is useful when the remote controller
is missing.

4. Suction grille: (Option)


Appearance of the suction grille and Air inlet
grille may differ with some models.

The operation mode refers to the following table.

5. Air inlet

CDKS
CDXS

6. Room temperature sensor:


It senses the air temperature around the unit.

Mode
COOL
AUTO

Temperature
setting
22C
25C

Air flow rate


AUTO
AUTO

7. Operation lamp (green)


8. TIMER lamp (yellow)
9. HOME LEAVE lamp (red):
Lights up when you use HOME LEAVE
operation.

Outdoor Unit
11. Air inlet: (Back and side)
12. Refrigerant piping and inter-unit cable

14. Earth terminal:


It is inside of this cover.

13. Drain hose

15. Air outlet

Appearance of the outdoor unit may differ from some models.

Operation Manual

317

Instruction

EDAU12-722

Remote Controller
1

5
3
6

9
7
8
10

13
15
14

12
11

ARC433B69, B76
1. Signal transmitter:
It sends signals to the indoor unit.
2. Display:
It displays the current settings.
(In this illustration, each section is shown
with all its displays ON for the purpose of
explanation.)
3. HOME LEAVE button:
HOME LEAVE operation
4. POWERFUL button:
POWERFUL operation
5. TEMPERATURE adjustment buttons:
It changes the temperature setting.
6. ON/OFF button:
Press this button once to start operation.
Press once again to stop it.

318

7. MODE selector button:


It selects the operation mode.
(AUTO/DRY/COOL/HEAT/FAN)
8. QUIET button: OUTDOOR UNIT
QUIET operation
9. FAN setting button:
It selects the air flow rate setting.
10. ON TIMER button
11. OFF TIMER button
12. TIMER Setting button:
It changes the time setting.
13. TIMER CANCEL button:
It cancels the timer setting.
14. CLOCK button
15. RESET button:
Restart the unit if it freezes.
Use a thin object to push.

Operation Manual

EDAU12-722

Instruction

FLXS 25/35/50/60 B

Names of parts
Indoor Unit
The indoor unit can be installed either to the ceiling or to a wall. The descriptions contained in this manual show the case when installation is being carried out to the ceiling. (The methods of operation used
are the same when installing to a wall.)

4
4

ON
OFF

5
9
8

7
6
11
10

12

14
13

Opening the front grille


How to open the front grille :

CAUTION
Before opening the front grille, be sure to stop the operation and turn the breaker OFF.

Operation Manual

319

Instruction

EDAU12-722

Outdoor Unit
15
17
18

16

19

Indoor Unit

1. Louvers (vertical blades):


The louvers are inside of the air outlet.
2. Air outlet
3. Flap (horizontal blade)
4. Grille tab

13. Indoor unit ON/OFF switch:


Push this switch once to start operation.
Push once again to stop it.
The operation mode refers to the following
table.

5. Air inlet

Mode

6. Display

AUTO

7. Air filter
8. Photocatalytic deodorizing filter or
Air purifying filter:
These filters are attached to the inside of the air
filters.
9. Front grille
10. Operation lamp (green)
11. TIMER lamp (yellow)
12. HOME LEAVE lamp (red):
Lights up when you use HOME LEAVE
Operation.

Temperature
setting
25C

Air flow rate


AUTO

Push the switch using an object with a sharp


tip, such as a pen.
This switch is useful when the remote controller
is missing.
14. Signal receiver:
It receives signals from the remote controller.
When the unit receives a signal, you will hear a
short beep.
Operation start .............beep-beep
Settings changed..........beep
Operation stop ..............beeeeep

Outdoor Unit
15. Air inlet: (Back and side)

18. Drain hose

16. Air outlet

19. Earth terminal:


It is inside of this cover.

17. Refrigerant piping and inter-unit cable

Appearance of the outdoor unit may differ from some models.

320

Operation Manual

EDAU12-722

Instruction

Remote Controller
1

ON

HOME LEAVE

ON/OFF

3
POWERFUL

TEMP

MODE
QUIET

FAN

4
7

SWING

9
10

CANCEL

14

8
11

ON
OFF

16

TIMER

15

13
12

< ARC433B67 >


1. Signal Transmitter:
It sends signals to the indoor unit.
2. Display:
It displays the current settings.
(In this illustration, each section is shown
with all its displays ON for the purpose of
explanation.)
3. HOME LEAVE button:
for HOME LEAVE operation
4. POWERFUL button:
for POWERFUL operation
5. TEMPERATURE adjustment buttons:
It changes the temperature setting.
6. ON/OFF button:
Press this button once to start operation.
Press once again to stop it.

Operation Manual

7. MODE selector button:


It selects the operation mode.
(AUTO/DRY/COOL/HEAT/FAN)
8. QUIET button
9. FAN setting button:
It selects the air flow rate setting.
10. SWING button
11. ON TIMER button
12. OFF TIMER button
13. TIMER Setting button:
It changes the time setting.
14. TIMER CANCEL button:
It cancels the timer setting.
15. CLOCK button
16. RESET button:
Restart the unit if it freezes.
Use a thin object to push.

321

Instruction

1.1.4

EDAU12-722

Preparation before Operation

Preparation Before Operation


To set the batteries
1. Slide the front cover to take it off.
2. Set two dry batteries (AAA).
3. Set the front cover as before.

ATTENTION
About batteries
When replacing the batteries, use batteries of the same type, and replace the two old batteries
together.
When the system is not used for a long time, take the batteries out.
We recommend replacing once a year, although if the remote controller display begins to fade or if
reception deteriorates, please replace with new alkali batteries. Do not use manganese batteries.
The attached batteries are provided for the initial use of the system.
The usable period of the batteries may be short depending on the manufactured date of the air
conditioner.

322

Operation Manual

EDAU12-722

Instruction

Preparation Before Operation


To operate the remote
controller
To use the remote controller, aim the transmitter
at the indoor unit. If there is anything to block
signals between the unit and the remote controller, such as a curtain, the unit will not operate.
Do not drop the remote controller. Do not get it wet.
The maximum distance for communication is
about 7m.

To fix the remote controller


holder on the wall
1. Choose a place from where the signals reach the unit.
2. Fix the holder to a wall, a pillar, etc.
with the screws supplied with the
holder.
3. Place the remote controller in the
remote controller holder.

ATTENTION
About remote controller
Never expose the remote controller to direct sunlight.
Dust on the signal transmitter or receiver will reduce the sensitivity. Wipe off dust with soft cloth.
Signal communication may be disabled if an electronic-starter-type fluorescent lamp (such as
inverter-type lamps) is in the room. Consult the shop if that is the case.
If the remote control signals happen to operate another appliance, move that appliance to somewhere else, or consult the shop.

Operation Manual

323

Instruction

EDAU12-722

To set the clock


1. Press CLOCK button.
is displayed.
blinks.

2. Press TIMER setting button


to set the clock to the present
time.
Holding down
or
button rapidly increases or decreases the time display.

3. Press CLOCK button.

ECONO
POWERFUL

ON/OFF
TEMP

MODE
SWING
FAN
QUIET MOLD PROOF SENSOR

blinks.

2
ON

Turn the breaker ON


Turning ON the breaker opens the flap, then
closes it again. (This is a normal procedure.)

CANCEL

1, 3

OFF

TIMER

NOTE
Tips for saving energy
Be careful not to cool (heat) the room too much.
Keeping the temperature setting at a moderate level helps save energy.
Cover windows with a blind or a curtain.
Blocking sunlight and air from outdoors increases the cooling (heating) effect.
Clogged air filters cause inefficient operation and waste energy. Clean them
once in about every two weeks.

Recommended temperature setting


For cooling:26C 28C
For heating:20C 24C

Please note
The air conditioner always consumes 15-35 watts of electricity even while it is not operating.
If you are not going to use the air conditioner for a long period, for example in spring or autumn, turn the breaker OFF.
Use the air conditioner in the following conditions.
Mode

Operating conditions

If operation is continued out of this range

COOL

Outdoor temperature:10 to 46C


Indoor temperature: 18 to 32C
Indoor humidity:
80% max.

A safety device may work to stop the operation.


(In multi system, it may work to stop the operation of the outdoor unit only.)
Condensation may occur on the indoor unit and drip.

HEAT

Outdoor temperature:10 to 20C


Indoor temperature: 10 to 30C

A safety device may work to stop the operation.

DRY

Outdoor temperature:10 to 46C


Indoor temperature: 18 to 32C
Indoor humidity:
80% max.

A safety device may work to stop the operation.


Condensation may occur on the indoor unit and drip.

Operation outside this humidity or temperature range may cause a safety device to disable the system.

324

Operation Manual

EDAU12-722

1.1.5

Instruction

AUTO DRY COOL HEAT FAN Operation

OPERATION

AUTO DRY COOL HEAT FAN Operation


The air conditioner operates with the operation mode of your
choice.
From the next time on, the air conditioner will operate with the
same operation mode.

To start operation
1. Press MODE selector button
and select a operation mode.
Each pressing of the button advances the
mode setting in sequence.

: AUTO

2, 3
1

: DRY
: COOL
: HEAT

QUIET

: FAN

5
ON

<FTKS>

CANCEL

OFF
TIMER

<FTXS>

2. Press ON/OFF button.


The OPERATION lamp lights up.

To stop operation
3. Press ON/OFF button again.
Then OPERATION lamp goes off.

To change the temperature setting


4. Press TEMPERATURE adjustment button.
DRY or FAN mode

AUTO or COOL or HEAT mode


Press

The temperature setting is not variable.

Operation Manual

to raise the temperature and press

to lower the temperature.

Set to the temperature you like.

325

Instruction

EDAU12-722

To change the air flow rate setting


5. Press FAN setting button.
DRY mode

AUTO or HEAT or COOL or FAN mode


Five levels of air flow rate setting from
plus

to

are available.

The air flow rate setting is not variable.

Indoor unit quiet operation


When the air flow is set to
, the noise from the indoor unit will become quieter.
Use this when making the noise quieter.
The unit might lose capacity when the air flow rate is set to a weak level.

NOTE
Note on HEAT operation
Since this air conditioner heats the room by taking heat from outdoor air to indoors, the heating
capacity becomes smaller in lower outdoor temperatures. If the heating effect is insufficient, it is
recommended to use another heating appliance in combination with the air conditioner.
The heat pump system heats the room by circulating hot air around all parts of the room. After the
start of heating operation, it takes some time before the room gets warmer.
In heating operation, frost may occur on the outdoor unit and lower the heating capacity. In that case,
the system switches into defrosting operation to take away the frost.
During defrosting operation, hot air does not flow out of indoor unit.
Note on COOL operation
This air conditioner cools the room by blowing the hot air in the room outside, so if the
outside temperature is high, performance drops.
Note on DRY operation
The computer chip works to rid the room of humidity while maintaining the temperature as
much as possible. It automatically controls temperature and fan strength, so manual
adjustment of these functions is unavailable.
Note on AUTO operation
In AUTO operation, the system selects a temperature setting and an appropriate operation mode
(COOL or HEAT) based on the room temperature at the start of the operation.
The system automatically reselects setting at a regular interval to bring the room temperature to
user-setting level.
If you do not like AUTO operation, you can manually select the operation mode and setting
you like.
Note on air flow rate setting
At smaller air flow rates, the cooling (heating) effect is also smaller.

326

Operation Manual

EDAU12-722

1.1.6

Instruction

Adjusting the Air Flow Direction

FTXS 20 D, FTXS 25/35 E

Adjusting the Air Flow Direction


You can adjust the air flow direction to increase your comfort.

To adjust the horizontal


blades (flaps)
1. Press SWING button.

is displayed on the LCD and the

flaps will begin to swing.


ECONO

2. When the flaps have reached the


desired position, press SWING
button once more.
The flaps will stop moving.

disappears from the LCD.

POWERFUL

ON/OFF
TEMP

MODE
FAN
SWING
QUIET MOLD PROOF SENSOR

ON

1, 2

CANCEL

OFF

TIMER

Operation Manual

327

Instruction

EDAU12-722

To adjust the vertical blades


(louvres)
Hold the knob and move the louvres.
(You will find a knob on the left-side and the right-side blades.)
When the unit is installed in the corner of a room,
the direction of the louvers should be facing away
from the wall.
If they face the wall, the wall will block off the wind,
causing the cooling (or heating) efficiency to drop.

Notes on flaps and louvres angles


When SWING button is selected, the flaps
swinging range depends on the operation mode.
(See the figure.)
If the unit is operated after being stopped with
the flaps pointed down in cooling or dry operation, the flaps will automatically move to a horizontal position after about one hour to prevent
condensation from forming on them.
ATTENTION
Always use a remote controller to adjust the flaps
angle. If you attempt to move it forcibly with hand
when it is swinging, the mechanism may be broken.
Be careful when adjusting the louvres. Inside the
air outlet, a fan is rotating at a high speed.

328

Operation Manual

EDAU12-722

Instruction

FTXS 50/60/71 F

Adjusting the Air Flow Direction


You can adjust the air flow direction to increase your
comfort.

To adjust the horizontal


blade (flap)
1. Press SWING button

is displayed on the LCD and the

flaps will begin to swing.

2. When the flap has reached the


desired position,
press SWING button
once
more.
The flap will stop moving.

1, 2
QUIET

3, 4

disappears from the LCD.


ON

CANCEL

OFF

TIMER

To adjust the vertical blades (louvers)


3. Press SWING button

is displayed on the LCD.

4. When the louvers have reached the desired position, press the
SWING button
once more.
The louvers will stop moving.

disappears from the LCD.

Operation Manual

329

Instruction

EDAU12-722

To 3-D Airflow
1. 3. Press the SWING button
and the SWING button
:
the and
display will light up and the flap and louvers will
move in turn.

To cancel 3-D Airflow


2. 4. Press either the SWING button

or the SWING button

Notes on louvers angles


ATTENTION
Always use a remote controller to adjust the louvers angles. In side the air outlet, a fan is rotating at a
high speed.

Notes on flap angle


When SWING button is selected, the flaps swinging
range depends on the operation mode. (See the figure.)
Three-Dimensional (3-D) Airflow
Using three-dimensional airflow circulates cold air,
which tends to collected at the bottom of the room, and
hot air, which tends to collect near the ceiling,
throughout the room, preventing areas of cold and hot
developing.
ATTENTION
Always use a remote controller to adjust the flaps angle.
If you attempt to move it forcibly with hand when it is
swinging, the mechanism may be broken.
Be careful when adjusting the louvers. Inside the air
outlet, fan is rotating at a high speed.

In COOL or DRY mode

STOP
COOL
DRY

In HEAT or FAN mode

STOP
HEAT
FAN

330

Operation Manual

EDAU12-722

Instruction

FLXS 25/35/50/60 B

Adjusting the Air Flow Direction


You can adjust the air flow direction to increase your comfort.

To adjust the horizontal


blade (flap)

ON
C

1. Press SWING button.


is displayed on the LCD.

2. When the flaps have reached the


desired position, press SWING
button once more.

HOME LEAVE

ON/OFF

POWERFUL

TEMP

MODE
QUIET

FAN

The flaps will stop moving.

ON

SWING

1, 2

CANCEL

OFF
TIMER

Operation Manual

331

Instruction

EDAU12-722

To adjust the vertical blades


(louvers)
When adjusting the louver, use a robust and stable stool and
watch your steps carefully.
Hold the knob and move the louvers.
(You will find a knob on the left side and the right side blades.)

Notes on flap and louvers angles


Unless [SWING] is selected, you should set the
flap at a near- horizontal angle in COOL or DRY
mode to obtain the best performance.
In COOL or DRY mode, if the flap is fixed at a
downward position, the flap automatically moves
in about 60 minutes to prevent condensation on it.
ATTENTION
Always use a remote controller to adjust the flap
angle.
If you attempt to move it forcibly with hand when it
is swinging, the mechanism may be broken.
Be careful when adjusting the louvers. Inside the
air outlet, a fan is rotating at a high speed.

332

DRY
COOL
FAN
HEAT

Operation Manual

EDAU12-722

1.1.7

Instruction

POWERFUL Operation

POWERFUL Operation
POWERFUL operation quickly maximizes the cooling
(heating) effect in any operation mode. You can get the
maximum capacity .

To start POWERFUL
operation
1. Press POWERFUL button.
POWERFUL operation ends in 20 minutes.
Then the system automatically operates
again with the settings which were used
before POWERFUL operation.
When using POWERFUL operation,
there are some functions which are not
available.

is displayed on the LCD.

To cancel POWERFUL
operation
2. Press POWERFUL button
again.

ECONO
POWERFUL

ON/OFF
TEMP

1, 2
MODE
FAN
SWING
QUIET MOLD PROOF SENSOR

ON

CANCEL

OFF

TIMER

disappears from the LCD.

NOTE
Notes on POWERFUL operation
POWERFUL Operation cannot be used together with ECONO or QUIET Operation.
Priority is given to the function of whichever button is pressed last.
POWERFUL Operation can only be set when the unit is running. Pressing the operation
stop button causes the settings to be canceled, and the disappears from the LCD.
In COOL and HEAT mode
To maximize the cooling (heating) effect, the capacity of outdoor unit must be increased
and the air flow rate be fixed to the maximum setting.
The temperature and air flow settings are not variable.
In DRY mode
The temperature setting is lowered by 2.5C and the air flow rate is slightly increased.
In FAN mode
The air flow rate is fixed to the maximum setting.
When using priority-room setting
See Note for multi system.

Operation Manual

333

Instruction

1.1.8

EDAU12-722

OUTDOOR UNIT QUIET Operation

OUTDOOR UNIT QUIET Operation


OUTDOOR UNIT QUIET operation lowers the noise
level of the outdoor unit by changing the frequency and
fan speed on the outdoor unit. T his function is
convenient during night.

To start OUTDOOR UNIT


QUIET operation
1. Press QUIET button.

is displayed on the LCD.

To cancel OUTDOOR UNIT


QUIET operation
2. Press QUIET button again.

QUIET

disappears from the LCD.

1, 2
ON

CANCEL

OFF

TIMER

NOTE
Note on OUTDOOR UNIT QUIET operation
If using a multi system, this function will work only when the OUTDOOR UNIT QUIET
operation is set on all operated indoor units.
However, if using priority-room setting, see Note for multi system
This function is available in COOL, HEAT, and AUTO modes.
(This is not available in FAN and DRY mode.)
POWERFUL operation and OUTDOOR UNIT QUIET operation cannot be used at the
same time.
Priority is given to the function of whichever button is pressed last.
If operation is stopped using the remote controller or the main unit ON/OFF switch when
using OUTDOOR UNIT QUIET operation,
will remain on the remote controller
display.

334

Operation Manual

EDAU12-722

1.1.9

Instruction

ECONO Operation

ECONO Operation
ECONO operation is a function which enables efficient operation by lowering the maximum power consumption value.

To start ECONO operation


1. Press ECONO button .

is displayed on the LCD.

To cancel ECONO operation

2. Press ECONO button again.

disappears from the LCD.

1, 2

ECONO
POWERFUL

ON/OFF
TEMP

MODE
FAN
SWING
QUIET MOLD PROOF SENSOR

ON

CANCEL

OFF

TIMER

NOTE
ECONO Operation can only be set when the unit is running. Pressing the operation stop
button causes the settings to be canceled, and the disappears from the LCD.
ECONO operation is a function which enables efficient operation by limiting the power
consumption of the outdoor unit (operating frequency).
ECONO operation functions in AUTO, COOL, DRY, and HEAT modes.
POWERFUL operation and ECONO operation cannot be used at the same time.
Priority is given to the function of whichever button is pressed last.
Power consumption may not drop even if ECONO operation is used, when the level of
power consumption is already low.

Operation Manual

335

Instruction

EDAU12-722

1.1.10 MOLD PROOF Operation

MOLD PROOF Operation


MOLD PROOF operation is a function which reduces the spread of mold by using Fan mode to lower
the humidity inside the indoor unit.

To set MOLD PROOF


operation
1. Press and hold the MOLD PROOF
button for two seconds.

is displayed on the LCD.

To cancel MOLD PROOF


operation
2. Press and hold the MOLD PROOF
button for two seconds one more
time.

disappears from the LCD.

ECONO
POWERFUL

ON/OFF
TEMP

MODE
FAN
SWING
QUIET MOLD PROOF SENSOR

1, 2
ON

CANCEL

OFF

TIMER

NOTE
MOLD PROOF operation will operate for approximately one hour after dry or cooling mode
is turned off.
This function is not designed to remove existing dust or mold.
MOLD PROOF operation is not available when the unit is turned off using the OFF TIMER.

336

Operation Manual

EDAU12-722

Instruction

1.1.11 HOME LEAVE Operation

HOME LEAVE Operation


HOME LEAVE operation is a function which allows you to record your preferred temperature and air
flow rate settings.

To start HOME LEAVE


operation
1. Press HOME LEAVE button.

is displayed on the LCD.

The HOME LEAVE lamp lights up.

4
1, 2

To cancel HOME LEAVE


operation
QUIET

2. Press HOME LEAVE button again.


disappears from the LCD.


ON

The HOME LEAVE lamp goes off.

CANCEL

OFF
TIMER

Before using HOME LEAVE operation.


To set the temperature and air flow rate for HOME LEAVE operation
When using HOME LEAVE operation for the first time, please set the temperature and air flow rate
for HOME LEAVE operation. Record your preferred temperature and air flow rate.
Initial setting
temperature

Selectable range

Air flow rate

temperature

Air flow rate

Cooling

25C

18-32C

5 step,

and

Heating

25C

10-30C

5 step,

and

1. Press HOME LEAVE button. Make sure is displayed in the remote


controller display.
2. Adjust the set temperature with
or
as you like.
3. Adjust the air flow rate with FAN setting button as you like.
Home leave operation will run with these settings the next time you use the unit. To change
the recorded information, repeat steps 1 3.

Operation Manual

337

Instruction

EDAU12-722

Whats the HOME LEAVE operation?


Is there a set temperature and air flow rate which is most comfortable, a set temperature and air flow rate which
you use the most? HOME LEAVE operation is a function that allows you to record your favorite set temperature
and air flow rate. You can start your favorite operation mode simply by pressing the HOME LEAVE button on the
remote controller. This function is convenient in the following situations.

Useful in these cases


1.Use as an energy-saving mode.
Set the temperature 2-3C higher (cooling) or lower (heating) than normal. Setting the fan strength to the lowest
setting allows the unit to be used in energy-saving mode. Also convenient for use while you are out or sleeping.

Every day before you leave the house...

When you go out, push the HOME LEAVE


Operation button, and the air conditioner
will adjust capacity to reach the preset
temperature for HOME LEAVE Operation.

When you return, you will be


welcomed by a comfortably air
conditioned room.

Push the HOME LEAVE Operation


button again, and the air conditioner
will adjust capacity to the set
temperature for normal operation.

The unit will maintain the


temperature in the room at a
comfortable level while you sleep.

When you enter the living room in the


morning, the temperature will be just right.

Before bed...

Set the unit to HOME LEAVE


Operation before leaving the living
room when going to bed.

Disengaging HOME LEAVE Operation


will return the temperature to that set
for normal operation. Even the coldest
winters will pose no problem!

2.Use as a favorite mode.


Once you record the temperature and air flow rate settings you most often use, you can retrieve them by
pressing HOME LEAVE button. You do not have to go through troublesome remote controller operations.

NOTE
Once the temperature and air flow rate for HOME LEAVE operation are set, those settings will be
used whenever HOME LEAVE operation is used in the future. To change these settings, please refer
to the Before using HOME LEAVE operation section above.
HOME LEAVE operation is only available in COOL and HEAT mode. Cannot be used in AUTO, DRY,
and FAN mode.
HOME LEAVE operation runs in accordance with the previous operation mode (COOL or HEAT)
before using HOME LEAVE operation.
HOME LEAVE operation and POWERFUL operation cannot be used at the same time.
Last button that was pressed has priority.
The operation mode cannot be changed while HOME LEAVE operation is being used.
When operation is shut off during HOME LEAVE operation, using the remote controller or the indoor
unit ON/OFF switch, will remain on the remote controller display.

338

Operation Manual

EDAU12-722

Instruction

1.1.12 INTELLIGENT EYE Operation


FTXS 20 D, FTXS 25/35 E

INTELLIGENT EYE Operation


INTELLIGENT EYE is the infrared sensor which
detects the human movement.

To start INTELLIGENT
EYE operation
1. Press SENSOR button.

To cancel the
INTELLIGENT EYE
operation
2. Press SENSOR button again.

is displayed on the LCD.

disappears from the LCD.

ECONO
POWERFUL

ON/OFF
TEMP

MODE
SWING
FAN
QUIET MOLD PROOF SENSOR

1, 2

[EX.]
When somebody in the room

ON

CANCEL

OFF

Normal operation

TIMER

When nobody in the room


20 min. after, start energy

saving

operation.

Somebody back in the room


Back to normal operation.

Operation Manual

339

Instruction

EDAU12-722

INTELLIGENT EYE is useful for Energy Saving


Energy saving operation
Change the temperature 2C in heating / +2C in cooling / +2C in dry mode from set temperature.
Decrease the air flow rate slightly in fan operation. (In FAN mode only)

Notes on INTELLIGENT EYE


Application range is as follows.

Sensor may not detect moving objects further than 7m away. (Check the application range)
Sensor detection sensitivity changes according to indoor unit location, the speed of passersby, temperature range, etc.
The sensor also mistakenly detects pets, sunlight, fluttering curtains and light reflected off of
mirrors as passersby.
INTELLIGENT EYE operatipon will not go on during powerful operation.
Night set mode will not go on during you use INTELLIGENT EYE operation.

CAUTION
Do not place large objects near the sensor.
Also keep heating units or humidifiers outside the sensors detection area. This sensor can
detect objects it shouldnt as well as not detect objects it should.
Do not hit or violently push the INTELLIGENT EYE sensor. Th is can lead to damage and
malfunction.

340

Operation Manual

EDAU12-722

Instruction

FTXS 50/60/71 F

INTELLIGENT EYE Operation


INTELLIGENT EYE is the infrared sensor which
detects the human movement.

To start INTELLIGENT
EYE operation
1. Press SENSOR button.

is displayed on the LCD.

To cancel the
INTELLIGENT EYE
operation
2. Press SENSOR button again.

QUIET

disappears from the LCD.

[EX.]

1, 2
ON

When somebody in the room

CANCEL

OFF
TIMER

Normal operation

When nobody in the room


20 min. after, start energy

saving

operation.

Somebody back in the room


Back to normal operation.

Operation Manual

341

Instruction

EDAU12-722

INTELLIGENT EYE is useful for Energy Saving.


Energy saving operation
Change the temperature 2C in heating / +2C in cooling / +1C in dry mode from set temperature.
Decrease the air flow rate slightly in fan operation. (In FAN mode only)

Notes on INTELLIGENT EYE


Application range is as follows.
Vertical angle 90
(Side View)

Horizontal angle 110


(Top View)

90

7m

55 55

7m

Sensor may not detect moving objects further than 7m away. (Check the application range)
Sensor detection sensitivity changes according to indoor unit location, the speed of
passersby, temperature range, etc.
The sensor also mistakenly detects pets, sunlight, fluttering curtains and light reflected off of
mirrors as passersby.
INTELLIGENT EYE operation will not go on during powerful operation.
Night set mode will not go on during you use INTELLIGENT EYE operation.

CAUTION
Do not place large objects near the sensor.
Also keep heating units or humidifiers outside the sensors detection area. This sensor can
detect objects it shouldnt as well as not detect objects it should.
Do not hit or violently push the INTELLIGENT EYE sensor. This can lead to damage and
malfunction.

342

Operation Manual

EDAU12-722

Instruction

1.1.13 TIMER Operation

TIMER Operation
Timer functions are useful for automatically switching the
air conditioner on or off at night or in the morning. You can
also use OFF TIMER and ON TIMER in combination.

To use OFF TIMER op eration


Check that the clock is correct.
If not, set the clock to the present time.

1. Press OFF TIMER button.


is displayed.

ECONO
POWERFUL

ON/OFF
TEMP

blinks.

2. Press TIMER Setting button


until the time setting reaches the
point you like.
Every pressing of either button increases
or decreases the time setting by 10 minutes. Holding down either button changes
the setting rapidly.

MODE
SWING
FAN
QUIET MOLD PROOF SENSOR

ON

CANCEL

2
4

OFF

TIMER

3. Press OFF TIMER button


again.

1, 3

The TIMER lamp lights up.

To cancel the OFF TIMER operation


4. Press CANCEL button.
The TIMER lamp goes off.

NOTE
When TIMER is set, the present time is not displayed.
Once you set ON, OFF TIMER, the time setting is kept in the memory. (The memory is canceled when
remote controller batteries are replaced.)
When operating the unit via the ON/OFF Timer, the actual length of operation may vary from the time
entered by the user. (Maximum approx. 10 minutes)
NIGHT SET MODE
When the OFF TIMER is set, the air conditioner automatically adjusts the temperature setting (0.5C
up in COOL, 2.0C down in HEAT) to prevent excessive cooling (heating) for your pleasant sleep.

Operation Manual

343

Instruction

EDAU12-722

To use ON TIME R operation


Check that the clock is correct. If not, set
the clock to the present time

1. Press ON TIMER button.


is displayed.
blinks.

2. Press TIMER Setting button


until the time setting reaches
the point you like.
Every pressing of either button
increases or decreases the time setting
by 10 minutes. Holding down either button changes the setting rapidly.

3. Press ON TIMER button


again.

ECONO
POWERFUL

ON/OFF
TEMP

MODE
SWING
FAN
QUIET MOLD PROOF SENSOR

1, 3

The TIMER lamp lights up.


ON

CANCEL

4
OFF

TIMER

To cancel ON TI MER
operation
4. Press CANCEL button.
The TIMER lamp goes off.

To combine ON TI MER and OFF TI MER


A sample setting for combining the two timers is shown below.

ATTENTION
In the following cases, set the timer again.
After a breaker has turned OFF.
After a power failure.
After replacing batteries in the remote controller.

344

Operation Manual

EDAU12-722

Instruction

1.1.14 Note for Multi System

Note for Multi System


What is a Multi System?
This system has one outdoor unit connected to multiple indoor units.

Selecting the Operation Mode


1. With the Priority Room Setting
present but inactive or not present.

A
room

Outdoor
unit
Living
room

B
room

When more than one indoor unit is operating, priority is


given to the first unit that was turned on.
C
room
In this case, set the units that are turned on later to the
same operation mode (*1) as the first unit.
Otherwise, they will enter the Standby Mode, and the operation lamp will flash; this does not indicate malfunction.
(*1)
COOL, DRY and FAN mode may be used at the same time.
AUTO mode automatically selects COOL mode or HEAT mode based on the room temperature.
Therefore, AUTO mode is available when selecting the same operation mode as that of the room
with the first unit to be turned on.
CAUTION
Normally, the operation mode in the room where the unit is first run is given priority, but the following situations are
exceptions, so please keep this in mind.
If the operation mode of the first room is FAN Mode, then using Heating Mode in any room after this will give priority to
heating. In this situation, the air conditioner running in FAN Mode will go on standby, and the operation lamp will flash.

2. With the Priority Room Setting active.


See Priority Room Setting on the next page.

NIGHT QUIET Mode (Available only for cooling operation)


NIGHT QUIET Mode requires initial programming during installation. Please consult your retailer or dealer for assistance.
NIGHT QUIET Mode reduces the operation noise of the outdoor unit during the night time hours to prevent
annoyance to neighbors.
The NIGHT QUIET Mode is activated when the temperature drops 5C or more below the highest temperature
recorded that day. Therefore, when the temperature difference is less than 5C, this function will not be activated.
NIGHT QUIET Mode reduces slightly the cooling efficiency of the unit.

OUTDOOR UNIT QUIET Operation


1. With the Priority Room Setting present but inactive or not present.
When using the OUTDOOR UNIT QUIET operation feature with the Multi system, set all indoor units to
OUTDOOR UNIT QUIET operation using their remote controllers.
When clearing OUTDOOR UNIT QUIET operation, clear one of the operating indoor units using their remote controller.
However OUTDOOR UNIT QUIET operation display remains on the remote controller for other rooms.
We recommend you release all rooms using their remote controllers.

2. With the Priority Room Setting active.


See Priority Room Setting on the next page.

Cooling / Heating Mode Lock (Available only for heat pump models)
The Cooling / Heating Mode Lock requires initial programming during installation.Please consult your retailer or dealer
for assistance. The Cooling / Heating Mode Lock sets the unit forcibly to either Cooling or Heating Mode. This function
is convenient when you wish to set all indoor units connected to the Multi system to the same operation mode.

Operation Manual

345

Instruction

EDAU12-722

Priority Room Setting


The Priority Room Setting requires initial programming during installation. Please consult your
retailer or dealer for assistance.
The room designated as the Priority Room takes priority in the following situations;

1. Operation Mode Priority.


As the operation mode of the Priority Room takes precedence, the user can select a different
operation mode from other rooms.
Example
* Room A is the Priority Room in the examples.
When COOL mode is selected in Room A while operating the following modes in Room B,C and D :

Operation mode in Room B, C and D


COOL or DRY or FAN

Status of Room B, C and D when the unit in Room A is in COOL mode


Current operation mode maintained

HEAT

The unit enters Standby Mode. Operation resumes when the


Room A unit stops operating.

AUTO

If the unit is set to COOL mode, operation continues. If set to


HEAT mode, it enters Standby Mode. Operation resumes when
the Room A unit stops operating.

2. Priority when POWERFUL operation is used.


Example
* Room A is the Priority Room in the examples.
The indoor units in Rooms A,B,C and D are all operating. If the unit in Room A enters POWERFUL
operation, operation capacity will be concentrated in Room A. In such a case, the cooling (heating)
efficiency of the units in Rooms B,C and D may be slightly reduced.

3. Priority when using OUTDOOR UNIT QUIET operation.


Example
* Room A is the Priority Room in the examples.
Just by setting the unit in Room A to QUIET operation, the air conditioner starts OUTDOOR UNIT
QUIET operation.
You dont have to set all the operated indoor units to QUIET operation.

346

Operation Manual

EDAU12-722

Instruction

1.1.15 Care and Cleaning


FTXS 20 D, FTXS 25/35 E

Care and Cleaning


CAUTION

Before cleaning, be sure to stop the operation and


turn the breaker OFF.

Units
Indoor unit, Outdoor unit and Remote controller

1. Wipe them with dry soft cloth.

Front panel
1. Open the front panel.
Hold the panel by the tabs on the two sides and lift
it unitl it stops with a click.

2. Remove the front panel.


Lift the front panel up, slide it slightly to the
right, and remove it from the horizontal axle.

3. Clean the front panel.


Wipe it with a soft cloth soaked in water.
Only neutral detergent may be used.
In case of washing the panel with water, dry it with
cloth, dry it up in the shade after washing.

4. Attach the front panel.


Set the 2 keys of the front panel into the slots and
push them in all the way.
Close the front panel slowly and push the panel at
the 3 points.
( 1 on each side and 1 in the middle.)

CAUTION

Dont touch the metal parts of the indoor unit. If you touch those parts, this may cause an injury.
When removing or attaching the front panel, use a robust and stable stool and watch your steps carefully.
When removing or attaching the front panel, support the panel securely with hand to prevent it from falling.
For cleaning, do not use hot water above 40C, benzine, gasoline, thinner, nor other volatile oils, polishing compound, scrubbing brushes, nor other hand stuff.
After cleaning, make sure that the front panel is securely fixed.

Operation Manual

347

Instruction

EDAU12-722

Filters
1. Open the front panel.
2. Pull out the air filters.
Push a little upwards the tab at the center of each air
filter, then pull it down.

3. Take off the Titanium Apatite


Photocatalytic Air-Purifying Filter.
Hold the recessed parts of the frame and
unhook the four claws.

4. Clean or replace each filter.

Titanium Apatite
Photocatalytic
Air-Purifying Filter

Air filter

Filter frame

See figure.
Tab

5. Set the air filter and Titanium Apatite


Photocatalytic Air-Purifying Filter as they
were and close the front panel.
Insert claws of the filters into slots of the front panel.
Close the front panel slowly and push the panel at the 3
points. (1 on each side and 1 in the middle.)

Air Filter
1. Wash the air filters with water or clean them with
vacuum cleaner.
If the dust does not come off easily, wash them with neutral detergent
thinned with lukewarm water, then dry them up in the shade.
It is recommended to clean the air filters every two weeks.

Titanium Apatite Photocatalytic


Air-Purifying Filter.
The Titanium Apatite Photocatalytic Air-Purifying Filter can be renewed
by washing it with water once every 6 months. We recommend replacing
it once every 3 years.

[ Maintenance ]
1. Remove dust with a vacuum cleaner and wash lightly with water.
2. If it is very dirty, soak it for 10 to 15 minutes in water mixed with a neutral cleaning agent.
3. Do not remove filter from frame when washing with water.
4. After washing, shake off remaining water and dry in the shade.
5. Since the material is made out of paper, do not wring out the filter
when removing water from it.

[ Replacement ]
1. Remove the tabs on the filter frame and replace with a new filter.
Dispose of the old filter as flammable waste.

348

Operation Manual

EDAU12-722

Instruction

NOTE
Operation with dirty filters:
(1) cannot deodorize the air.
(2) cannot clean the air.
(3) results in poor heating or cooling. (4) may cause odour.
To order Titanium Apatite Photocatalytic Air-Purifying Filter contact to the service shop
there you bought the air conditioner.
Dispose of old filters as burnable waste.
Item
Titanium Apatite Photocatalytic Air-Purifying Filter.
(without frame) 1 set

Part No.
KAF970A46

Check
Check that the base, stand and other fittings of the outdoor unit are not decayed or corroded.
Check that nothing blocks the air inlets and the outlets of the indoor unit and the outdoor unit.
Check that the drain comes smoothly out of the drain hose during COOL or DRY operation.
If no drain water is seen, water may be leaking from the indoor unit. Stop operation and consult the service shop if this is the case.

Before a long idle period


1. Operate the Fan only for several hours on a fine day to dry out the
inside.
Press MODE selector button and select Fanoperation.
Press ON/OFF button and start operation.

2. After operation stops, turn off the breaker for the room air conditioner.
3. Clean the air filters and set them again.
4. Take out batteries from the remote controller.
When a multi outdoor unit is connected, make sure the heating operation is not used at the
other room before you use the fan operation.

Operation Manual

349

Instruction

EDAU12-722

FTXS 50/60/71 F

CARE

Care and Cleaning


CAUTION

Before cleaning, be sure to stop the operation and


turn the breaker OFF.

Units
Indoor unit, outdoor unit and remote controller
1. Wipe them with dry soft cloth.

Front panel
1. Open the front panel.
Hold the panel by the tabs on the two
sides and lift it until it stops with a
click.

2. Remove the front panel.


Open the front panel
further while sliding it to
either the left or right
and pulling it toward
you. This will disconnect
the rotation dowel on
one side. Then
disconnect the rotation
dowel on the other side
in the same manner.

3. Clean the front panel.


Wipe it with a soft cloth soaked in water.
Only neutral detergent may be used.
In case of washing the panel with water, dry it with cloth, dry it up in the shade after washing.

4. Attach the front panel.


Align the rotation dowels on the left and right of the front panel
with the slots, then push them all the way in.
Close the front panel slowly. (Press the panel at both sides
and the center.)

CAUTION

Dont touch the metal parts of the indoor unit. If you touch those parts, this may cause an injury.
When removing or attaching the front panel, use a robust and stable stool and watch your steps carefully.
When removing or attaching the front panel, support the panel securely with hand to prevent it from falling.
For cleaning, do not use hot water above 40C, benzine, gasoline, thinner, nor other volatile oils,
polishing compound, scrubbing brushes, nor other hand stuff.
After cleaning, make sure that the front panel is securely fixed.

350

Operation Manual

EDAU12-722

Instruction

Filters
1. Open the front panel.
2. Pull out the air filters.
Push a little upwards the tab at the
center of each air filter, then pull it
down.

3. Take off the Titanium


Apatite Photocatalytic
Air-Purifying Filter.
Press the top of the aircleaning filter onto the tabs
(3 at top). Then press the
bottom of the filter up
slightly, and press it onto
the tabs (3 at bottom).

tabs (3 at top)

4
tabs (3 at bottom)

4. Clean or replace each filter.


See figure.

5. Set the air filter and the Titanium


Apatite Photocatalytic Air-Purifying
Filter as they were and close the front
panel.
Press the front panel at both sides and the
center.

Air Filter
1. Wash the air filters with water or clean them with
vacuum cleaner.
If the dust does not come off easily, wash them with neutral
detergent thinned with lukewarm water, then dry them up in the
shade.
It is recommended to clean the air filters every two weeks.

Titanium Apatite Photocatalytic Air-purifying Filter


The Titanium Apatite Photocatalytic Air-Purifying Filter can be renewed by washing it with water
once every 6 months. We recommend replacing it once every 3 years.

[ Maintenance ]
1.
2.
3.
4.

Remove dust with a vacuum cleaner and wash lightly with water.
If it is very dirty, soak it for 10 to 15 minutes in water mixed with a neutral cleaning agent.
After washing, shake off remaining water and dry in the shade.
Since the material is made out of polyester, do not wring out the filter
when removing water from it.

[ Replacement ]
1. Remove the tabs on the filter frame and replace with a new filter.
Dispose of the old filter as non-flammable waste.

Operation Manual

351

Instruction

EDAU12-722

NOTE
Operation with dirty filters:
(1) cannot deodorize the air.
(2) cannot clean the air.
(3) results in poor heating or cooling.
(4) may cause odour.
To order Titanium Apatite Photocatalytic Air-Purifying Filter contact to the service shop
there you bought the air conditioner.
Dispose of old filters as non-flammable waste.
Item
Titanium Apatite Photocatalytic Air-Purifying Filter.
(without frame) 1 set

Part No.
KAF952B42

Check
Check that the base, stand and other fittings of the outdoor unit are not decayed or corroded.
Check that nothing blocks the air inlets and the outlets of the indoor unit and the outdoor unit.
Check that the drain comes smoothly out of the drain hose during COOL or DRY operation.
If no drain water is seen, water may be leaking from the indoor unit. Stop operation and consult the
service shop if this is the case.

Before a long idle period


1. Operate the FAN only for several hours on a fine day to dry out the
inside.
Press MODE button and select FAN operation.
Press ON/OFF button and start operation.

2. After operation stops, turn off the breaker for the room air conditioner.
3. Clean the air filters and set them again.
4. Take out batteries from the remote controller.
NOTE)When a multi outdoor unit is connected, make sure the heating operation is not used at
the other room before you use the fan operation.

352

Operation Manual

EDAU12-722

Instruction

FDXS 25/35/50/60 C

Care and Cleaning


CAUTION

Only a qualified service person is allowed to


perform maintenance.
Before cleaning, be sure to stop the operation
and turn the breaker OFF.

Cleaning the air filter

1.Removing the air filter.


Rear suction
Pull the bottom side of the air filter backwards, over the 3 bends.
Bottom suction
Pull the filter over the 3 bends situated at the backside of the unit.

2.Cleaning the air filter.


Remove dust from the air filter using a vacuum cleaner and
gently rinse them in cool water. Do not use detergent or hot
water to avoid filter shrinking or deformation. After cleaning
dry them in the shade.

3.Replacing the air filter.


Rear suction
Hook the filter behind the flap situated at the top of the unit
and push the other side gently over the 3 bends.
Bottom suction
Hook the filter behind the flap situated at the middle of the unit and push the other side gently
over the 3 bends.

Main unit
Force

Filter
Force

In case of back side

Operation Manual

Attach the filter to the


main unit while
pushing down on the
tabs.

In case of bottom side

353

Instruction

EDAU12-722

Cleaning the drain pan


Clean the drain pan periodically, or drain piping may be clogged with dust and may result in water leakage.
Ask your DAIKIN dealer to clean them.
Prepare a cover locally to prevent any dust in the air around the indoor unit from getting in the drain pan, if
there is a great deal of dust present.

CAUTION
Do not operate the air conditioner without filters, this to avoid dust accummulation inside the
unit.
Do not remove the air filter except when cleaning.
Unnecessary handling may damage the filter.
Do not use gasoline, benzene, thinner, polishing powder, liquid insecticide, It may cause discoloring or
warping.
Do not let the indoor unit get wet. It may cause an electric shock or a fire.
Operation with dusty air filters lowers the cooling and heating capacity and wastes energy.
The suction grille is option.
Do not use water or air of 50C or higher for cleaning air filters and outside panels.

Check
Check that the base, stand and other fittings of the outdoor unit are not decayed or corroded.
Check that nothing blocks the air inlets and the outlets of the indoor unit and the outdoor unit.
Check that the drain comes smoothly out of the drain hose during COOL or DRY operation.
If no drain water is seen, water may be leaking from the indoor unit. Stop operation and consult the
service shop if this is the case.

Before a long idle period


1. Operate the Fan only for several hours on a fine day to dry out the inside.
Press MODE selector button and select FAN operation.
Press ON/OFF button and start operation.

2. After operation stops, turn off the breaker for the room air conditioner.
3. Clean the air filters and set them again.
4. Take out batteries from the remote controller.
When a multi outdoor unit is connected, make sure the heating operation is not used at the
other room before you use the fan operation.

354

Operation Manual

EDAU12-722

Instruction

CDXS 25/35 E

Care and Cleaning


CAUTION

Only a qualified service person is allowed to


perform maintenance.
Before cleaning, be sure to stop the operation
and turn the breaker OFF.

Cleaning the air filter

1.Removing the air filter.


Rear suction
Pull the bottom side of the air filter backwards, over the bends.
Bottom suction
Pull the filter over the bends situated at the backside of the unit.

2.Cleaning the air filter.


Remove dust from the air filter using a vacuum cleaner and
gently rinse them in cool water. Do not use detergent or hot
water to avoid filter shrinking or deformation. After cleaning
dry them in the shade.

3.Replacing the air filter.


Rear suction
Hook the filter behind the flap situated at the top of the unit
and push the other side gently over the bends.
Bottom suction
Hook the filter behind the flap situated at the middle of the unit and push the other side gently
over the bends.

Main unit
Force

Filter
Force

In case of back side

Operation Manual

Attach the filter to the


main unit while
pushing down on the
bends.

In case of bottom side

355

Instruction

EDAU12-722

Cleaning the drain pan


Clean the drain pan periodically, or drain piping may be clogged with dust and may result in water leakage.
Ask your DAIKIN dealer to clean them.
Prepare a cover locally to prevent any dust in the air around the indoor unit from getting in the drain pan, if
there is a great deal of dust present.

CAUTION
Do not operate the air conditioner without filters, this to avoid dust accumulation inside the
unit.
Do not remove the air filter except when cleaning.
Unnecessary handling may damage the filter.
Do not use gasoline, benzene, thinner, polishing powder, liquid insecticide, It may cause discoloring or
warping.
Do not let the indoor unit get wet. It may cause an electric shock or a fire.
Operation with dusty air filters lowers the cooling and heating capacity and wastes energy.
The suction grille is option.
Do not use water or air of 50C or higher for cleaning air filters and outside panels.
Ask your DAIKIN dealer how to clean it.

Check
Check that the base, stand and other fittings of the outdoor unit are not decayed or corroded.
Check that nothing blocks the air inlets and the outlets of the indoor unit and the outdoor unit.
Check that the drain comes smoothly out of the drain hose during COOL or DRY operation.
If no drain water is seen, water may be leaking from the indoor unit. Stop operation and consult the service shop if this is the case.

Before a long idle period


1. Operate the FAN only for several hours on a fine day to dry out the
inside.
Press MODE selector button and select FAN operation.
Press ON/OFF button and start operation.

2. After operation stops, turn off the breaker for the room air conditioner.
3. Clean the air filters and set them again.
4. Take out batteries from the remote controller.
When a multi outdoor unit is connected, make sure the heating operation is not used at the
other room before you use the fan operation.

356

Operation Manual

EDAU12-722

Instruction

FLXS 25/35/50/60 B

Care and Cleaning


CAUTION

Before cleaning, be sure to stop the operation and


turn the breaker OFF.

Units
Indoor unit, Outdoor unit and Remote controller
1. Wipe them with dry soft cloth.

Front grille
1. Open the front grille.
Hold the grille by the tabs on the two sides and lift
it unitl it stops.
ON
OFF

2. Clean the front grille


Wipe it with a soft cloth soaked in water.
Only neutral detergent may be used.
In case of washing the grille with water, dry it with
cloth, dry it up in the shade after washing.

3. Close the front grille


Push the grille at the 5 points indicated by .
Operation without air filters may result in troubles
as dust will accumulate inside the indoor unit.

ON
OFF

CAUTION

Dont touch the metal parts of the indoor unit. If you touch those parts, this may cause an injury.
When opening and closing the front grille, use a robust and stable stool and watch your steps carefully.
When opening and closing the front grille, support the grille securely with hand to prevent it from falling.
For cleaning, do not use hot water above 40 C, benzine, gasoline, thinner, nor other volatile oils, polishing compound, scrubbing brushes, nor other hand stuff.
After cleaning, make sure that the front grille is securely fixed.

Operation Manual

357

Instruction

EDAU12-722

Filters
1. Open the front grille.
2. Pull out the air filters.
Push upwards the tab at the center of each air filter, then pull it down.

ON
OFF

3. Take off the air purifying filter,


photocatalytic deodorizing filter.
Hold the recessed parts of the frame and unhook
the four claws.

ON
OFF

4. Clean or replace each filter.


See figure.

Air purifying filter


or Photocatalytic
deodorizing filter

5. Set the air filter, air purifying filter


and photocatalytic deodorizing filter as
they were and close the front grille.

ON
OFF

Insert claws of the filters into slots of the front grille.


Push the grille at the 5 points.

Air Filter
1. Wash the air filters with water or clean them
with vacuum cleaner.
If the dust does not come off easily, wash them with neutral detergent thinned with lukewarm water, then dry them up in the shade.
It is recommended to clean the air filters every two weeks.

Air Purifying Filter (green)


(Replace approximately once every 3 months.)

1. Detach the filter element and attach a new one.


Insert with the green side up.
It is recommended to replace the air purifying filter every three months.

Photocatalytic Deodorizing Filter (gray)


[ Maintenance ]
1. Dry the photocatalytic deodorizing filter in the sun.
After removing the dust with a vacuum cleaner, place the filter in the sun for approximately 6 hours.
By drying the photocatalytic deodorizing filter in the sun, its deodorizing and antibacterial capabilities
are regenerated.
Because the filter material is paper, it can not be cleaned with water.
It is recommended dry the filter once every 6 months.

[ Replacement ]
1. Detach the filter element and attach a new one.

358

Operation Manual

EDAU12-722

Instruction

Check
Check that the base, stand and other fittings of the outdoor unit are not decayed or corroded.
Check that nothing blocks the air inlets and the outlets of the indoor unit and the outdoor unit.
Check that the drain comes smoothly out of the drain hose during COOL or DRY operation.
If no drain water is seen, water may be leaking from the indoor unit. Stop operation and consult the service shop if this is the case.

Before a long idle period


1. Operate the FAN only for several hours on a fine day to dry out the
inside.

Press MODE selector button and select FAN operation.


Press ON/OFF button and start operation.

2. After operation stops, turn off the breaker for the room air conditioner.
3. Clean the air filters and set them again.
4. Take out batteries from the remote controller.
When a multi outdoor unit is connected, make sure the heating operation is not used at the other room
before you use the fan operation.

NOTE
Operation with dirty filters :
(1) cannot deodorize the air.
(2) cannot clean the air.
(3) results in poor heating or cooling.
(4) may cause odour.
The air purifying filter and Photocatalytic deodorizing filter cannot be reused, even if washed.
In principle, there is no need to replace the photocatalytic deodorizing filter. Remove the dust periodically with a vacuum cleaner. However, it is recommended to replace the filter in the following
cases.
(1) The paper material is torn or broken during cleaning.
(2) The filter has become extremely dirty after long use.
To order air purifying filter or Photocatalytic deodorizing filter, contact to the service shop where you
bought the air conditioner.
Dispose of old air filters as non-burnable waste and Photocatalytic deodorizing filters as
burnable waste.
Item

Part No.

Photocatalytic deodorizing filter (with frame)

KAZ917B41

Photocatalytic deodorizing filter (without frame)

KAZ917B42

Air purifying filter (with frame)

KAF925B41

Air purifying filter (without frame)

KAF925B42

Operation Manual

359

Instruction

EDAU12-722

1.1.16 Troubleshooting

Trouble Shooting
These cases are not troubles.
The following cases are not air conditioner troubles but have some reasons. You may just continue using it.

Case

360

Explanation

Operation does not start soon.


When ON/OFF button was
pressed soon after
operation was stopped.
When the mode was
reselected.

This is to protect the air conditioner.


You should wait for about 3 minutes.

Hot air does not flow out soon


after the start of heating
operation.

The air conditioner is warming up. You should wait for 1 to 4


minutes.
(The system is designed to start discharging air only after it
has reached a certain temperature.)

The heating operation stops


suddenly and a flowing sound
is heard.

The system is taking away the frost on the outdoor unit.


You should wait for about 3 to 8 minutes.

The outdoor unit emits water or


steam.

In HEAT mode
The frost on the outdoor unit melts into water or steam
when the air conditioner is in defrost operation.
In COOL or DRY mode
Moisture in the air condenses into water on the cool
surface of outdoor unit piping and drips.

Mists come out of the indoor


unit.

This happens when the air in the room is cooled into mist by
the cold air flow during cooling operation.

The indoor unit gives out odour.

This happens when smells of the room, furniture, or


cigarettes are absorbed into the unit and discharged with the
air flow.
(If this happens, we recommend you to have the indoor unit
washed by a technician. Consult the service shop where you
bought the air conditioner.)

The outdoor fan rotates while


the air conditioner is not in
operation.

After operation is stopped:


The outdoor fan continues rotating for another 60
seconds for system protection.
While the air conditioner is not in operation:
When the outdoor temperature is very high, the out door
fan starts rotating for system protection.

The operation stopped


suddenly.
(OPERATION lamp is on)

For system protection, the air conditioner may stop


operating on a sudden large voltage fluctuation.
It automatically resumes operation in about 3 minutes.

Operation Manual

EDAU12-722

Instruction

Check again.
Please check again before calling a repair person.

Case
The air conditioner does not
operate.
(OPERATION lamp is off)

Check
Hasnt a breaker turned OFF or a fuse blown?
Isnt it a power failure?
Are batteries set in the remote controller?
Is the timer setting correct?

Cooling (Heating) effect is poor. Are the air filters clean?


Is there anything to block the air inlet or the outlet of the
indoor and the outdoor units?
Is the temperature setting appropriate?

Are the windows and doors closed?


Are the air flow rate and the air direction set appropriately?
Is the unit set to the INTELLIGENT EYE mode?
Operation stops suddenly.
(OPERATION lamp flashes.)

Are the air filters clean?


Is there anything to block the air inlet or the outlet of the
indoor and the outdoor units?
Clean the air filters or take all obstacles away and turn the
breaker OFF. Then turn it ON again and try operating the air
conditioner with the remote controller. If the lamp still flashes,
call the service shop where you bought the air conditioner.
Are operation modes all the same for indoor units
connected to outdoor units in the multi system?
If not, set all indoor units to the same operation mode and
confirm that the lamps flash.
Moreover, when the operation mode is in AUTO, set all
indoor unit operation modes to COOL or HEAT for a
moment and check again that the lamps are normal.
If the lamps stop flashing after the above steps, there is no
malfunction.

An abnormal functioning
happens during operation.

Operation Manual

The air conditioner may malfunction with lightning or radio


waves. Turn the breaker OFF, turn it ON again and try
operating the air conditioner with the remote controller.

361

Instruction

EDAU12-722

Call the service shop immediately.

WARNING
When an abnormality (such as a burning smell) occurs, stop operation and turn the breaker OFF.
Continued operation in an abnormal condition may result in troubles, electric shocks or fire.
Consult the service shop where you bought the air conditioner.
Do not attempt to repair or modify the air conditioner by yourself.
Incorrect work may result in electric shocks or fire.
Consult the service shop where you bought the air conditioner.

If one of the following symptoms takes place, call the service shop immediately.

The power cord is abnormally hot or damaged.


An abnormal sound is heard during operation.
The safety breaker, a fuse, or the earth leakage breaker
cuts off the operation frequently.
A switch or a button often fails to work properly.
There is a burning smell.
Water leaks from the indoor unit.

After a power failure


The air conditioner automatically resumes
operation in about 3 minutes. You should just
wait for a while.

Turn the breaker


OFF and call the
service shop.

Lightning
If lightning may strike the neighbouring area,
stop operation and turn the breaker OFF for
system protection.

We recommend periodical maintenance.


In certain operating conditions, the inside of the air conditioner may get foul after several seasons of
use, resulting in poor performance. It is recommended to have periodical maintenance by a specialist
aside from regular cleaning by the user. For specialist maintenance, contact the service shop where
you bought the air conditioner.
The maintenance cost must be born by the user.

362

Operation Manual

EDAU12-722

1.2

Instruction

FVXS Series

Safety precautions

Keep this manual where the operator can easily find them.
Read this manual attentively before starting up the unit.
For safety reason the operator must read the following cautions carefully.
This manual classifies precautions into WARNING and CAUTION. Be sure to follow all precautions
below: they are all important for ensuring safety.

WARNING

CAUTION

If you do not follow these instructions exactly, the unit may If you do not follow these instructions exactly, the unit may
cause property damage, personal injury or loss of life.
cause minor or moderate property damage or personal injury.

Never do.

Be sure to follow the instructions.

Be sure to earth the air conditioner.

Never cause the air conditioner (including the


remote controller) to get wet.

Never touch the air conditioner (including the


remote controller) with a wet hand.

WARNING
In order to avoid fire, explosion or injury, do not operate the unit when harmful, among
which flammable or corrosive gases, are detected near the unit.
It is not good for health to expose your body to the air flow for a long time.
Do not put a finger, a rod or other objects into the air outlet or inlet. As the fan is rotating at
a high speed, it will cause injury.
Do not attempt to repair, relocate, modify or reinstall the air conditioner by yourself. Incorrect work
will cause electric shocks, fire etc.
For repairs and reinstallation, consult your Daikin dealer for advice and information.
The refrigerant used in the air conditioner is safe. Although leaks should not occur, if for
some reason any refrigerant happens to leak into the room, make sure it does not come in
contact with any flame as of gas heaters, kerosene heaters or gas range.
If the air conditioner is not cooling (heating) properly, the refrigerant may be leaking, so call your dealer.
When carrying out repairs accompanying adding refrigerant, check the content of the repairs with our service staff.
Do not attempt to install the air conditioner by your self. Incorrect work will result in water leakage,
electric shocks or fire. For installation, consult the dealer or a qualified technician.
In order to avoid electric shock, fire or injury, if you detect any abnormally such as smell of fire, stop
the operation and turn off the breaker. And call your dealer for instructions.
Depending on the environment, an earth leakage breaker must be installed. Lack of an earth leakage breaker may result in electric shocks or fire.

The air conditioner must be earthed. Incomplete earthing may result in electric shocks. Do
not connect the earth line to a gas pipe, water pipe, lightning rod, or a telephone earth line.

CAUTION
In order to avoid any quality deterioration, do not use the unit for cooling precision instruments, food, plants, animals or works of art.
Never expose little children, plants or animals directly to the air flow.

Operation Manual

363

Instruction

EDAU12-722

Do not place appliances which produce open fire in places exposed to the air flow from the unit or
under the indoor unit. It may cause incomplete combustion or deformation of the unit due to the heat.
Do not block air inlets nor outlets. Impaired air flow may result in insufficient performance or trouble.
Do not stand or sit on the outdoor unit. Do not place any object on the unit to avoid injury, do not remove the fan guard.
Do not place anything under the indoor or outdoor unit that must be kept away from moisture. In certain conditions, moisture in the air may condense and drip.
After a long use, check the unit stand and fittings for damage.
Do not touch the air inlet and alminum fins of outdoor unit. It may cause injury.
The appliance is not intended for use by young children or infirm persons without supervision.
Young children should be supervised to ensure that they do not play with the appliance.
To avoid oxygen deficiency, ventilate the room sufficiently if equipment with burner is used
together with the air conditioner.
Before cleaning, be sure to stop the operation, turn the breaker off or pull out the supply cord.
Do not connect the air conditioner to a power supply different from the one as specified. It
may cause trouble or fire.
Arrange the drain hose to ensure smooth drainage. Incomplete draining may cause wetting of the
building, furniture etc.
Do not place objects in direct proximity of the outdoor unit and do not let leaves and other debris
accumulate around the unit.
Leaves are a hotbed for small animals which can enter the unit. Once in the unit, such animals can
cause malfunctions, smoke or fire when making contact with electrical parts.
Do not operate the air conditioner with wet hands.

Do not wash the indoor unit with excessive water, only use a slightly wet cloth.
Do not place things such as vessels containing water or anything else on top of the unit. Water
may penetrate into the unit and degrade electrical insulations, resulting in an electric shock.

Installation site.
To install the air conditioner in the following types of environments, consult the dealer.
Places with an oily ambient or where steam or soot occurs.
Salty environment such as coastal areas.
Places where sulfide gas occurs such as hot springs.
Places where snow may block the outdoor unit.
The drain from the outdoor unit must be discharged to a place of good drainage.

Consider nuisance to your neighbours from noises.


For installation, choose a place as described below.
A place solid enough to bear the weight of the unit which does not amplify the operation noise or vibration.
A place from where the air discharged from the outdoor unit or the operation noise will not annoy
your neighbours.

Electrical work.
For power supply, be sure to use a separate power circuit dedicated to the air conditioner.

System relocation.
Relocating the air conditioner requires specialized knowledge and skills. Please consult the
dealer if relocation is necessary for moving or remodeling.

364

Operation Manual

EDAU12-722

Instruction

Names of parts
Indoor Unit
1

12
10

4
2
9
5

11

Opening the Front Panel


How to open the front panel: (page 26.)
Air outlet selection switch

This setting blows air from upper outlet only.

This setting automatically decides a blow


pattern depending on mode and conditions.

This setting is
recommended.

13

The unit is shipped from the


factory with this setting.

14

CAUTION
Before opening the front panel, be sure to stop the operation and turn the breaker OFF.
Do not touch the metal parts on the inside of the indoor unit, as it may result in injury.

Operation Manual

365

Instruction

EDAU12-722

Outdoor Unit
15
16
17
19

18

Indoor Unit
1. Titanium Apatite Photocatalytic
Air-Purifying Filter:
These filters are attached to the inside of
the air filters.
2. Air outlet
3. Display
4. Front panel
5. Louvers (vertical blades): (page 12.)
The louvers are inside of the air outlet.
6. Air inlet
7. Air filter
8. Flap (horizontal blade): (page 12.)
9. Operation lamp (green)
10. TIMER lamp (yellow): (page 17.)
11. Indoor Unit ON/OFF switch:
Push this switch once to start operation.
Push once again to stop it.

The operation mode refers to the following


table.
Temperature
setting
COOL
22C
AUTO
25C
Mode

Air flow rate


AUTO
AUTO

This switch is useful when the remote


controller is missing.
12. Signal receiver:
It receives signals from the remote
controller.
When the unit receives a signal, you will
hear a short beep.
Operation start ........ beep-beep
Settings changed ..... beep
Operation stop.......... beeeeep
13. Air outlet selection switch: (page 13.)
14. Room temperature sensor:
It senses the air temperature around the unit.

Outdoor Unit
15. Air inlet: (Back and side)
16. Refrigerant piping and inter-unit cable

18. Earth terminal:


It is inside of this cover.

17. Drain hose

19. Air outlet

Appearance of the outdoor unit may differ from some models.

366

Operation Manual

EDAU12-722

Instruction

Remote Controller
1

2
5
3

<Open the lid>

7
8
11
14
16
17
19

9
10
12
13
15
18
20

<ARC452A2>
1. Signal transmitter:
It sends signals to the indoor unit.
2. Display:
It displays the current settings.
(In this illustration, each section is shown
with all its displays ON for the purpose of
explanation.)
3. FAN setting button:
It selects the air flow rate setting.
4. POWERFUL button:
POWERFUL operation (page 14.)
5. ON/OFF button:
Press this button once to start operation.
Press once again to stop it.
6. TEMPERATURE adjustment buttons:
It changes the temperature setting.
7. MODE selector button:
It selects the operation mode.
(AUTO/DRY/COOL/HEAT/FAN) (page 10.)
8. QUIET button:
OUTDOOR UNIT QUIET operation (page 15.)

9. ECONO button:
ECONO operation (page 16.)
10. SWING button:
Adjusting the Air Flow Direction (page 12.)
11. WEEKLY button:
WEEKLY TIMER operation (page 19.)
12. PROGRAM button:
WEEKLY TIMER operation (page 19.)
13. COPY button:
WEEKLY TIMER operation (page 19.)
14. BACK button:
WEEKLY TIMER operation (page 19.)
15. NEXT button:
WEEKLY TIMER operation (page 19.)
16. SELECT button:
It changes the timer setting (page 17.)
17. OFF TIMER button: (page 17.)
18. ON TIMER button: (page 18.)
19. TIMER CANCEL button:
It cancels the timer setting. (page 17, 18.)
It cannot be used for the WEEKLY TIMER operation.
20. CLOCK button: (page 8.)

Operation Manual

367

Instruction

EDAU12-722

Preparation Before Operation


To set the batteries

1. Slide the front cover to take it off.

Position and
correctly!

2. Set two dry batteries (LR03AAA).


3. Set the front cover as before.

3
1

To operate the remote controller


To use the remote controller, aim the transmitter at the indoor
unit. If there is anything to block signals between the unit and
the remote controller, such as a curtain, the unit will not
operate.
Do not drop the remote controller. Do not get it wet.
The maximum distance for communication is about 7m.
Receiver

To fix the remote controller holder


on the wall
Remote
controller
holder

1. Choose a place from where the signals


reach the unit.
2. Fix the holder to a wall, a pillar, etc. with the
screws supplied with the holder.
3. Place the remote controller in the remote
controller holder.

Set.

To remove, pull it
upwards.

ATTENTION
About batteries
When replacing the batteries, use batteries of the same type, and replace the two old batteries together.
When the system is not used for a long time, take the batteries out.
We recommend replacing once a year, although if the remote controller display begins to fade or if reception
deteriorates, please replace with new alkaline batteries. Using manganese batteries reduces the lifespan.
The attached batteries are provided for the initial use of the system.
The usable period of the batteries may be short depending on the manufactured date of the air conditioner.
About remote controller
Never expose the remote controller to direct sunlight.
Dust on the signal transmitter or receiver will reduce the sensitivity. Wipe off dust with soft cloth.
Signal communication may be disabled if an electronic-starter-type fluorescent lamp (such
as inverter-type lamps) is in the room. Consult the shop if that is the case.
If the remote controller signals happen to operate another appliance, move that appliance
to somewhere else, or consult the shop.

368

Operation Manual

EDAU12-722

Instruction

Preparation Before Operation


To set the clock
1. Press CLOCK button.
is displayed.
and

blinks.

2. Press SELECT button to set


the current day of the week.
3. Press CLOCK button.

blinks.

4. Press SELECT button to set


the clock to the present time.
Holding down
or
button
rapidly increases or decreases the time
display.

5. Press CLOCK button.


Always point the remote controller at the
indoor unit when pushing the buttons
when setting the indoor units internal
clock.
blinks.

2, 4

1, 3, 5

NOTE
If the indoor units internal clock is not set to the correct time, the WEEKLY TIMER will not
operate punctually.

Operation Manual

369

Instruction

EDAU12-722

Turn the breaker ON


Turning ON the breaker closes the flap. (This is a normal procedure.)

NOTE
Tips for saving energy
Be careful not to cool (heat) the room too much.
Keeping the temperature setting at a moderate level helps save energy.
Cover windows with a blind or a curtain.
Blocking sunlight and air from outdoors increases the cooling (heating) effect.
Clogged air filters cause inefficient operation and waste energy.
Clean them once in about every two weeks.

Recommended temperature setting


For cooling:26C 28C
For heating:20C 24C

Please note
The air conditioner always consumes 15-35 watts of electricity even while it is not operating.
If you are not going to use the air conditioner for a long period, for example in spring or autumn, turn the breaker OFF.
Use the air conditioner in the following conditions.
Mode

Operating conditions

If operation is continued out of this range

COOL

Outdoor temperature: 3MXS 5 to 46C


4MXS 10 to 46C
3/4MKS 10 to 46C
RXS 10 to 46C
Indoor temperature: 18 to 32C
Indoor humidity: 80% max.

A safety device may work to stop the operation.


(In multi system, it may work to stop the operation of
the outdoor unit only.)
Condensation may occur on the indoor unit and drip.

HEAT

Outdoor temperature: 3/4MXS 15 to 24C


A safety device may work to stop the operation.
RXS25/35/50 15 to 24C
Indoor temperature: 10 to 30C

DRY

Outdoor temperature: 3MXS 5 to 46C


4MXS 10 to 46C
3/4MKS 10 to 46C
RXS 10 to 46C
Indoor temperature: 18 to 32C
Indoor humidity: 80% max.

A safety device may work to stop the operation.


Condensation may occur on the indoor unit and drip.

Operation outside this humidity or temperature range may cause a safety device to disable the system.

370

Operation Manual

EDAU12-722

Instruction

AUTO DRY COOL HEAT FAN Operation


The air conditioner operates with the operation
mode of your choice.
From the next time on, the air conditioner will
operate with the same operation mode.

To start operation
1. Press MODE selector button
and select a operation mode.
Each pressing of the button advances
the mode setting in sequence.

: AUTO
: DRY

5
4

: COOL
: HEAT
: FAN

2, 3

2. Press ON/OFF button.


The OPERATION lamp lights up.

To stop operation
3. Press ON/OFF button again.
Then OPERATION lamp goes off.

To change the temperature setting


4. Press TEMPERATURE adjustment button.
DRY or FAN mode

AUTO or COOL or HEAT mode


Press

The temperature setting is not variable.

to raise the temperature and press

to lower the temperature.

Set to the temperature you like.

10

Operation Manual

371

Instruction

EDAU12-722

To change the air flow rate setting


5. Press FAN setting button.
DRY mode

AUTO or COOL or HEAT or FAN mode


Five levels of air flow rate setting from
plus

to

are available.

The air flow rate setting is not variable.

Indoor unit quiet operation


When the air flow is set to , the noise from the indoor unit will become quieter.
Use this when making the noise quieter.
The unit might lose capacity when the air flow rate is set to a weak level.

NOTE
Note on HEAT operation
Since this air conditioner heats the room by taking heat from outdoor air to indoors, the heating
capacity becomes smaller in lower outdoor temperatures. If the heating effect is insufficient, it
is recommended to use another heating appliance in combination with the air conditioner .
The heat pump system heats the room by circulating hot air around all parts of the room.
After the start of heating operation, it takes some time before the room gets warmer.
In heating operation, frost may occur on the outdoor unit and lower the heating capacity. In
that case, the system switches into defrosting operation to take away the frost.
During defrosting operation, hot air does not flow out of indoor unit.
Note on COOL operation
This air conditioner cools the room by blowing the hot air in the room outside, so if the
outside temperature is high, performance drops.
Note on DRY operation
The computer chip works to rid the room of humidity while maintaining the temperature as
much as possible. It automatically controls temperature and fan strength, so manual
adjustment of these functions is unavailable.
Note on AUTO operation
In AUTO operation, the system selects a temperature setting and an appropriate operation
mode (COOL or HEAT) based on the room temperature at the start of the operation.
The system automatically reselects setting at a regular interval to bring the room
temperature to user-setting level.
If you do not like AUTO operation, you can manually select the operation mode and setting
you like.
Note on air flow rate setting
At smaller air flow rates, the cooling (heating) effect is also smaller.

11

372

Operation Manual

EDAU12-722

Instruction

Adjusting the Air Flow Direction


You can adjust the air flow direction to increase
your comfort.

To adjust the horizontal


blade (flap)
1. Press SWING button.

is displayed on the LCD and the
flaps will begin to swing.

2. When the flap has reached the


desired position, press
SWING button once more.

The flap will stop moving.


disappears from the LCD.

1, 2

To adjust the vertical


blades (louvers)
Hold the knob and move the louver.
(You will find a knob on the left-side and the rightside blades.)

Notes on flap and louvers angle


Unless SWING is selected, you should set the
flap at a near-horizontal angle in HEAT mode and
at a upward position in COOL or DRY mode to
obtain the best performance.

HEAT
COOL/
DRY

ATTENTION
When adjusting the flap by hand, turn off the unit,
and use the remote controller to restart the unit.
Be careful when adjusting the louvers. Inside the
air outlet, a fan is rotating at a high speed.

12

Operation Manual

373

Instruction

EDAU12-722

Air flow selection


Make air flow selection according to what suits you.

When setting the air flow selection switch to

Air conditioner automatically decides the appropriate blowing pattern depending on the operating
mode/situation.
Operating mode

Situation

Blowing pattern

COOL mode

When the room has become fully


cool, or when one hour has
passed since turning on the air
conditioner.

So that air does not come into


direct contact with people, air is
blown upper air outlet, room temperature is equalized.

At start of operation or other


times when the room is not fully
cooled.
At times other than below.
(Normal time.)

Air is blown from the upper and


lower air outlets for high speed
cooling during COOL mode, and
for filling the room with warm air
during HEAT mode.

HEAT mode

At start or when air temperature


is low.

So that air does not come into


direct contact with people. Air is
blown upper air outlet.

During Dry mode, so that cold air does not come into direct contact with people, air is blown
upper air outlet.

When setting the air outlet selection switch to

Regardless of the operating mode or situation, air blows from the upper air outlet.
Use this switch when you do not want air coming out of the lower air outlet. (While sleeping etc.)

CAUTION
Do not try to adjust the flap by hand.
When adjusting by hand, the mechanism may not operate properly or condensation may drip
from air outlets.

13

374

Operation Manual

EDAU12-722

Instruction

POWERFUL Operation
POWERFUL operation quickly maximizes the
cooling (heating) effect in any operation mode.
You can get the maximum capacity.

To start POWERFUL
operation
1. Press POWERFUL button.
POWERFUL operation ends in
20minutes. Then the system
automatically operates again with the
settings which were used before
POWERFUL operation.
When using POWERFUL operation,
there are some functions which are
not available.

is displayed on the LCD.

4
1, 2

To cancel POWERFUL
operation
2. Press POWERFUL button
again.

disappears from the LCD.

NOTE
Notes on POWERFUL operation
POWERFUL Operation cannot be used together with ECONO or QUIET Operation.
Priority is given to the function of whichever button is pressed last.
POWERFUL Operation can only be set when the unit is running. Pressing the operation
stop button causes the settings to be canceled, and the disappears from the LCD.
In COOL and HEAT mode
To maximize the cooling (heating) effect, the capacity of outdoor unit must be increased
and the air flow rate be fixed to the maximum setting.
The temperature and air flow settings are not variable.
In DRY mode
The temperature setting is lowered by 2.5C and the air flow rate is slightly increased .
In FAN mode
The air flow rate is fixed to the maximum setting.
When using priority-room setting
See Note for Multi System. (page 24.)

14

Operation Manual

375

Instruction

EDAU12-722

OUTDOOR UNIT QUIET Operation


OUTDOOR UNIT QUIET operation lowers the
noise level of the outdoor unit by changing the
frequency and fan speed on the outdoor unit.
This function is convenient during night.

To start OUTDOOR
UNIT QUIET operation
1. Press QUIET button.

is displayed on the LCD.

To cancel OUTDOOR
UNIT QUIET operation
2. Press QUIET button again.

disappears from the LCD.

1, 2

NOTE
Note on OUTDOOR UNIT QUIET operation
If using a multi system, this function will work only when the OUTDOOR UNIT QUIET
operation is set on all operated indoor units.
However, if using priority-room setting, see Note for Multi System. (page 24.)
This function is available in COOL, HEAT, and AUTO modes.
(This is not available in FAN and DRY mode.)
POWERFUL operation and OUTDOOR UNIT QUIET operation cannot be used at the
same time.
Priority is given to the function of whichever button is pressed last.
If operation is stopped using the remote controller or the main unit ON/OFF switch when
using OUTDOOR UNIT QUIET operation,
will remain on the remote controller
display.

15

376

Operation Manual

EDAU12-722

Instruction

ECONO Operation
ECONO operation is a function which enables
efficient operation by lowering the maximum
power consumption value.

To start ECONO
operation
1. Press ECONO button.

is displayed on the LCD.

To cancel ECONO
operation

2. Press ECONO button again.

disappears from the LCD.

1, 2

NOTE
ECONO Operation can only be set when the unit is running. Pressing the operation stop
button causes the settings to be canceled, and the disappears from the LCD.
ECONO operation is a function which enables efficient operation by limiting the power
consumption of the outdoor unit (operating frequency).
ECONO operation functions in AUTO, COOL, DRY, and HEAT modes.
POWERFUL operation and ECONO operation cannot be used at the same time.
Priority is given to the function of whichever button is pressed last.
Power consumption may not drop even if ECONO operation is used, when the level of
power consumption is already low.

16

Operation Manual

377

Instruction

EDAU12-722

TIMER Operation
Timer functions are useful for automatically
switching the air conditioner on or off at night or in
the morning. You can also use OFF TIMER and
ON TIMER in combination.

To use OFF TIMER


operation
Check that the clock is correct.
If not, set the clock to the present time.
(page 8.)

1. Press OFF TIMER button.


is displayed.
blinks.

2. Press SELECT button until


the time setting reaches the
point you like.
Every pressing of either button
increases or decreases the time
setting by 10 minutes. Holding down
either button changes the setting
rapidly.

3. Press OFF TIMER button


again.

1, 3
4

The TIMER lamp lights up.

To cancel the OFF TIMER Operation


4. Press CANCEL button.
The TIMER lamp goes off.

NOTE
When TIMER is set, the present time is not displayed.
Once you set ON, OFF TIMER, the time setting is kept in the memory. (The memory is
canceled when remote controller batteries are replaced.)
When operating the unit via the ON/OFF Timer, the actual length of operation may vary from
the time entered by the user. (Maximum approx. 10 minutes)
NIGHT SET MODE
When the OFF TIMER is set, the air conditioner automatically adjusts the temperature
setting (0.5C up in COOL, 2.0C down in HEAT) to prevent excessive cooling (heating) for
your pleasant sleep.

17

378

Operation Manual

EDAU12-722

Instruction

TIMER Operation
To use ON TIMER
operation
Check that the clock is correct. If not, set
the clock to the present time. (page 8.)

1. Press ON TIMER button.


is displayed.
blinks.

2. Press SELECT button until


the time setting reaches the
point you like.
Every pressing of either button
increases or decreases the time setting
by 10 minutes. Holding down either
button changes the setting rapidly.

3. Press ON TIMER button


again.
The TIMER lamp lights up.

2
1, 3

To cancel ON TIMER
operation

4. Press CANCEL button.


The TIMER lamp goes off.

To combine ON TIMER and OFF TIMER


A sample setting for combining the two timers is shown below.

Display

(Example)
Present time: 11:00 p.m.
(The unit operating)
OFF TIMER at 0:00 a.m.
ON TIMER at 7:00 a.m.

Combined

ATTENTION
In the following cases, set the timer again.
After a breaker has turned OFF.
After a power failure.
After replacing batteries in the remote controller.

18

Operation Manual

379

Instruction

EDAU12-722

WEEKLY TIMER Operation


Up to 4 timer settings can be saved for each day of the week.

To use WEEKLY TIMER operation


Make sure the day of the week and time are set.
If not, set the day of the week and time. (page 8.)
The following procedure is to make a reservation
on Monday for Tuesday 6:00 am/27C.

1. Press

button.

The day of the week and the reservation


number will be displayed.
1 to 4 settings can be made per day.

2. Press the SELECT button to select the desired


day of the week and reservation number.
Pressing the SELECT button changes the
reservation number and the day of the week.

3. Press NEXT button.

3, 5

The day of the week will be set.


and

blink.

2, 4, 6

4. Press SELECT button to select the desired mode.


and

or

will flash.

ON TIMER

OFF TIMER

no setting

To go to the next reservation setting, select no setting.

5. Press NEXT button.


The weekly mode will be set.

and
blink.

6. Press SELECT button to select the desired time.


The time can be set between 0:00 and 23:50 in 10 minute intervals.
Press BACK button to return to the mode setting.

19

380

Operation Manual

EDAU12-722

Instruction

WEEKLY TIMER Operation


7. Press NEXT button.
The time will be set.

and the temperature blink.

8. Press SELECT button to


select the desired temperature.
The temperature can be set between
10C and 32C.
To return to the time setting, press
BACK button.
The set temperature is only displayed
when the mode setting is on.

9. Press NEXT button.


The temperature will be set.
The temperature will be set and go to
the next reservation setting.
Set the following using the same
procedures.

10.Press
button to
complete the setting.
Point the remote controller toward the
air conditioner and press the buttons to
operate. The air conditioner will beep
and the operation lamp will flash.

10

7, 9
8

20

Operation Manual

381

Instruction

EDAU12-722

To cancel WEEKLY
TIMER operation
11.Press WEEKLY button to
deactivate the WEEKLY
operation.
The
will disappear from the
display.
The TIMER lamp goes off.
To reactivate the WEEKLY TIMER
operation, press the WEEKLY button
again.

11

NOTE
WEEKLY TIMER
Do not forget to set the time on the remote control first.
The day of the week, time and ON/OFF can be set with WEEKLY TIMER. For ON-TIMER, settings
other than the above are based on the remote controller settings just before the operation.
The WEEKLY button activates or deactivates the reservation.
To set WEEKLY TIMER, press
button and make a reservation according to the procedures.
Only the time and set temperature set with the weekly timer are sent with the
button.
Set the weekly timer only after setting the operation mode, the fan strength, and the fan
direction ahead of time.
Up to 4 settings per day and up to 28 settings per week can be reserved with WEEKLY
TIMER. If a reservation deactivated with WEEKLY button is activated once again, the last
reservation made will be used.
Cooling: The unit operates at 18C even if it is set at 10 to 17C.
Heating: The unit operates at 30C even if it is set at 31 to 32C.
Shutting the breaker off, power outages, and other similar events will render operation of the
indoor units internal clock inaccurate. Reset the clock. (page 8.)
The BACK button can be used only for the mode, time and temperature settings.
It cannot be used to go back to the reservation number.

21

382

Operation Manual

EDAU12-722

Instruction

WEEKLY TIMER Operation


Confirming a
reservation
The reservation can be confirmed.

1. Press

button.

The day of the week and the reservation


number of the current day will be
displayed.

4
2. Press SELECT button to
select the day of the week and
the reservation number to be
confirmed.
Pressing the SELECT button displays
the reservation details.

1, 3
4, 6
3. Press

button.

Reservation confirmation complete.

Canceling all
reservations

2, 5

4. Hold the WEEKLY button for 5 seconds.


Be sure to direct the remote control toward the main unit and check for a receiving tone.
This operation is not effective while WEEKLY TIMER is being set.
All reservations will be canceled.

Canceling individual reservations


This function can be used for canceling reservations for each day of the week.
It can be used while confirming or setting reservations.

5. Select the day of the week to be canceled with the SELECT button.
6. Hold the WEEKLY button for 5 seconds.
The selected reservation will be canceled.

22

Operation Manual

383

Instruction

EDAU12-722

Setting WEEKLY TIMER


using copy mode
A reservation made once can be easily copied and
the same settings used for another day of the week.

1. Press
button.
2. Press SELECT button to confirm
the day of the week to be copied.

3. Press COPY button.


This activates copy mode.
Copy whole reservation of the selected day of the week.

4. Press SELECT button to select


the destination day of the week.

1, 6
3, 5

2, 4
5. Press COPY button.
The reservation will be copied to the selected day of the week. The whole reservation of the
selected day of the week will be copied.
The reservation can be copied to another day of the week in succession.

6. Press

button.

Exit copy mode.

NOTE
COPY MODE
The entire reservation of the source day of the week is copied in the copy mode.
Detailed settings can be made after the copy is completed.
Both WEEKLY TIMER and ON/OFF timer cannot be used at the same time. The ON/OFF timer has priority if it is set
while WEEKLY TIMER is still active. WEEKLY TIMER is activated after the reserved ON/OFF timer is completed.

23

384

Operation Manual

EDAU12-722

Instruction

Note for Multi System


What is a Multi System?
This system has one outdoor unit connected to
multiple indoor units.

A
room

Outdoor
unit

Selecting the operation mode


1. With the Priority Room Setting
present but inactive or not present.

B
room

Living
room
C
room

When more than one indoor unit is operating, priority is given to the first unit that was turned on.
In this case, set the units that are turned on later
to the same operation mode (*1) as the first unit.
Otherwise, they will enter the Standby Mode, and the operation lamp will flash; this does not indicate malfunction.
(*1)
COOL, DRY and FAN mode may be used at the same time.
AUTO mode automatically selects COOL mode or HEAT mode based on the room temperature.
Therefore, AUTO mode is available when selecting the same operation mode as that of the room
with the first unit to be turned on.
CAUTION
Normally, the operation mode in the room where the unit is first run is given priority, but the
following situations are exceptions, so please keep this in mind.
If the operation mode of the first room is FAN Mode, then using Heating Mode in any room after this will give priority to
heating. In this situation, the air conditioner running in FAN Mode will go on standby, and the operation lamp will flash.

2. With the Priority Room Setting active.


See Priority Room Setting on the next page.

NIGHT QUIET Mode (Available only for cooling operation)


NIGHT QUIET Mode requires initial programming during installation. Please consult your retailer or dealer for assistance.
NIGHT QUIET Mode reduces the operation noise of the outdoor unit during the night time hours to
prevent annoyance to neighbors.
The NIGHT QUIET Mode is activated when the temperature drops 5C or more below the highest temperature
recorded that day. Therefore, when the temperature difference is less than 5C, this function will not be activated.
NIGHT QUIET Mode reduces slightly the cooling (heating) efficiency of the unit.

OUTDOOR UNIT QUIET operation (page 15.)


1. With the Priority Room Setting present but inactive or not present.
When using the OUTDOOR UNIT QUIET operation feature with the Multi system, set all
indoor units to OUTDOOR UNIT QUIET operation using their remote controllers.
When clearing OUTDOOR UNIT QUIET operation, clear one of the operating indoor units using their remote controller.
However OUTDOOR UNIT QUIET operation display remains on the remote controller for other rooms.
We recommend you release all rooms using their remote controllers.

2. With the Priority Room Setting active.


See Priority Room Setting on the next page.

Cooling / Heating mode lock (Available only for heat pump models)
The Cooling / Heating Mode Lock requires initial programming during installation.Please consult your retailer or dealer
for assistance. The Cooling / Heating Mode Lock sets the unit forcibly to either Cooling or Heating Mode. This function
is convenient when you wish to set all indoor units connected to the Multi system to the same operation mode.

24

Operation Manual

385

Instruction

EDAU12-722

Priority Room Setting


The Priority Room Setting requires initial programming during installation. Please consult your
retailer or dealer for assistance.
The room designated as the Priority Room takes priority in the following situations;

1. Operation mode Priority.


As the operation mode of the Priority Room takes precedence, the user can select a different
operation mode from other rooms.
Example
* Room A is the Priority Room in the examples.
When COOL mode is selected in Room A while operating the following modes in Room B,C and D:
Operation mode in Room
B, C and D
COOL or DRY or FAN

Status of Room B, C and D when the unit in Room


A is in COOL mode
Current operation mode maintained

HEAT

The unit enters Standby Mode. Operation resumes when


the Room A unit stops operating.

AUTO

If the unit is set to COOL mode, operation continues. If set


to HEAT mode, it enters Standby Mode. Operation
resumes when the Room A unit stops operating.

2. Priority when POWERFUL operation is used.


Example
* Room A is the Priority Room in the examples.
The indoor units in Rooms A,B,C and D are all operating. If the unit in Room A enters
POWERFUL operation, operation capacity will be concentrated in Room A. In such a case,
the cooling (heating) efficiency of the units in Rooms B,C and D may be slightly reduced.

3. Priority when using OUTDOOR UNIT QUIET operation.


Example
* Room A is the Priority Room in the examples.
Just by setting the unit in Room A to QUIET operation, the air conditioner starts OUTDOOR
UNIT QUIET operation.
You dont have to set all the operated indoor units to QUIET operation.

25

386

Operation Manual

EDAU12-722

Instruction

Care and Cleaning


CAUTION

Before cleaning, be sure to stop the operation and


turn the breaker OFF.

Units
Indoor unit, Outdoor unit and Remote controller
1. Wipe them with dry soft cloth.

Front panel
1. Open the front panel.
Slide the two stoppers on the left and right
sides inward until they click.

2. Remove the front panel.


Remove the string.
Allowing the front panel to fall forward will
enable you to remove it.

String

3. Clean the front panel.


Wipe it with a soft cloth soaked in water.
Only neutral detergent may be used.
In case of washing the front panel with water,
dry it with cloth, dry it up in the shade after
washing.

4. Attach the front panel.


Insert the front panel into the grooves of the
unit (3 places).
Attach the string to the right, inner-side of the
front grille.
Close the panel slowly.

String

Place front
panel in
grooves.

CAUTION
Dont touch the metal parts of the indoor unit. If you touch those parts, this may cause an
injury.
When removing or attaching the front panel, use a robust and stable stool and watch your
steps carefully.
When removing or attaching the front panel, support the panel securely with hand to prevent
it from falling.
For cleaning, do not use hot water above 40C, benzine, gasoline, thinner, nor other volatile
oils, polishing compound, scrubbing brushes, nor other hand stuff.
After cleaning, make sure that the front panel is securely fixed.

26

Operation Manual

387

Instruction

EDAU12-722

Filters
1. Open the front panel. (page 26.)

2. Remove the air filter.


Press the claws on the right and left of the air
filter down slightly, then pull upward.

3. Take off the Titanium Apatite


Photocatalytic Air-Purifying Filter.
Hold the tabs of the frame, and remove the
claws in 4 places.

4. Clean or replace each filter.


See figure.

5. Set the air filter and Titanium Apatite


Photocatalytic Air-Purifying Filter as
they were and close the front panel.

Titanium Apatite
Photocatalytic
Air-Purifying
Filter

Air filter

Operation without air filters may result in


troubles as dust will accumulate inside the
indoor unit.

Air Filter
1. Wash the air filters with water or clean them with
vacuum cleaner.
If the dust does not come off easily, wash them with neutral
detergent thinned with lukewarm water, then dry them up in the
shade.
It is recommended to clean the air filters every 2 weeks.

Titanium Apatite Photocatalytic


Air-Purifying Filter
The Titanium Apatite Photocatalytic Air-Purifying Filter can be renewed by washing it with water
once every 6 months. We recommend replacing it once every 3 years.

[ Maintenance ]
1. Vacuum dusts, and soak in warm water or water for about 10 to 15
minutes if dirt is heavy.
2. Do not remove filter from frame when washing with water.
3. After washing, shake off remaining water and dry in the shade.
4. Since the material is made out of paper, do not wring out the filter when removing water from it.

[ Replacement ]
1. Remove the tabs on the filter frame and replace with a new filter.
Dispose of the old filter as flammable waste.

27

388

Operation Manual

EDAU12-722

Instruction

NOTE
Operation with dirty filters:
(1) cannot deodorize the air.
(2) cannot clean the air.
(3) results in poor heating or cooling. (4) may cause odour.
To order Titanium Apatite Photocatalytic Air-Purifying Filter contact to the service shop
there you bought the air conditioner.
Dispose of old filters as flammable waste.
Item
Titanium Apatite Photocatalytic Air-Purifying Filter
(without frame) 1 set

Part No.
KAF968A42

Check
Check that the base, stand and other fittings of the outdoor unit are not decayed or corroded.
Check that nothing blocks the air inlets and the outlets of the indoor unit and the outdoor unit.
Check that the drain comes smoothly out of the drain hose during COOL or DRY operation.
If no drain water is seen, water may be leaking from the indoor unit. Stop operation and
consult the service shop if this is the case.

Before a long idle period


1. Operate the FAN only for several hours on a fine day to dry out the
inside.
Press MODE button and select FANoperation.
Press ON/OFF button and start operation.

2. After operation stops, turn off the breaker for the room air conditioner.
3. Clean the air filters and set them again.
4. Take out batteries from the remote controller.

NOTE
When a multi outdoor unit is connected, make sure the heating operation is not used at
the other room befure you use the fan operation. (page 24.)

28

Operation Manual

389

Instruction

EDAU12-722

Trouble Shooting
These cases are not troubles.
The following cases are not air conditioner troubles but have some reasons. You may just continue
using it.

Case

Explanation

Operation does not start soon. This is to protect the air conditioner.
You should wait for about 3 minutes.
When ON/OFF button was
pressed soon after operation
was stopped.
When the mode was reselected.
Hot air does not flow out soon
after the start of heating
operation.

The air conditioner is warming up. You should wait for 1 to 4


minutes.
(The system is designed to start discharging air only after it
has reached a certain temperature.)

The heating operation stops


suddenly and a flowing sound
is heard.

The system is taking away the frost on the outdoor unit.


You should wait for about 4 to 12 minutes.

The outdoor unit emits water or


steam.

In HEAT mode
The frost on the outdoor unit melts into water or steam
when the air conditioner is in defrost operation.
In COOL or DRY mode
Moisture in the air condenses into water on the cool
surface of outdoor unit piping and drips.

Mist comes out of the indoor


unit.

This happens when the air in the room is cooled into mist by
the cold air flow during cooling operation.
This is because the air in the room is cooled by the heat
exchanger and becomes mist during defrost operation.

The indoor unit gives out odour.

This happens when smells of the room, furniture, or


cigarettes are absorbed into the unit and discharged with the
air flow.
(If this happens, we recommend you to have the indoor unit
washed by a technician. Consult the service shop where you
bought the air conditioner.)

The outdoor fan rotates while


the air conditioner is not in
operation.

After operation is stopped:


The outdoor fan continues rotating for another 60 seconds
for system protection.
While the air conditioner is not in operation:
When the outdoor temperature is very high, the outdoor
fan starts rotating for system protection.

The operation stopped


suddenly.
(OPERATION lamp is on.)

For system protection, the air conditioner may stop operating


on a sudden large voltage fluctuation.
It automatically resumes operation in about 3 minutes.

29

390

Operation Manual

EDAU12-722

Instruction

Check again.
Please check again before calling a repair person.

Case
The air conditioner does not
operate.
(OPERATION lamp is off.)

Check

Hasnt a breaker turned OFF or a fuse blown?


Isnt it a power failure?
Are batteries set in the remote controller?
Is the timer setting correct?

Cooling (Heating) effect is poor. Are the air filters clean?


Is there anything to block the air inlet or the outlet of the
indoor and the outdoor units?
Is the temperature setting appropriate?
Are the windows and doors closed?
Are the air flow rate and the air direction set appropriately?
Operation stops suddenly.
(OPERATION lamp flashes.)

Are the air filters clean?


Is there anything to block the air inlet or the outlet of the
indoor and the outdoor units?
Clean the air filters or take all obstacles away and turn the
breaker OFF. Then turn it ON again and try operating the air
conditioner with the remote controller. If the lamp still flashes,
call the service shop where you bought the air conditioner.
Are operation modes all the same for indoor units connected
to outdoor units in the multi system?
If not, set all indoor units to the same operation mode and
confirm that the lamps flash.
Moreover, when the operation mode is in AUTO, set all
indoor unit operation modes to COOL or HEAT for a
moment and check again that the lamps are normal.
If the lamps stop flashing after the above steps, there is no
malfunction.
(page 24.)

An abnormal functioning
happens during operation.

The air conditioner may malfunction with lightning or radio


waves. Turn the breaker OFF, turn it ON again and try
operating the air conditioner with the remote controller.

30

Operation Manual

391

Instruction

EDAU12-722

Call the service shop immediately.

WARNING
When an abnormality (such as a burning smell) occurs, stop operation and turn the breaker OFF.
Continued operation in an abnormal condition may result in troubles, electric shocks or fire.
Consult the service shop where you bought the air conditioner.
Do not attempt to repair or modify the air conditioner by yourself.
Incorrect work may result in electric shocks or fire.
Consult the service shop where you bought the air conditioner.
If one of the following symptoms takes place, call the service shop immediately.

The power cord is abnormally hot or damaged.


An abnormal sound is heard during operation.
The safety breaker, a fuse, or the earth leakage breaker
cuts off the operation frequently.
A switch or a button often fails to work properly.
There is a burning smell.
Water leaks from the indoor unit.
After a power failure
The air conditioner automatically resumes
operation in about 3 minutes. You should just
wait for a while.

Turn the breaker


OFF and call the
service shop.

Lightning
If lightning may strike the neighbouring area,
stop operation and turn the breaker OFF for
system protection.

We recommend periodical maintenance.


In certain operating conditions, the inside of the air conditioner may get foul after several seasons of
use, resulting in poor performance. It is recommended to have periodical maintenance by a specialist
aside from regular cleaning by the user. For specialist maintenance, contact the service shop where
you bought the air conditioner.
The maintenance cost must be born by the user.

31
C : 3P191290-2A

392

Operation Manual

EDAU12-722

1.3

Instruction

FFQ Series
5 12

3
7

hr

C
hr

6
8

NOT
AVAILABLE

TEST

9
11
10
13

L H

14

21

20
TEST

19

17

15

16

18

22

e
d

h
f
g

b
d
c

hr

l
2

[1]

Operation Manual

393

Instruction

EDAU12-722

1. WHAT TO DO BEFORE
OPERATION
This operation manual is for the following systems
with standard control. Before initiating operation,
contact your Daikin dealer for the operation that
corresponds to your sysem.
Pair system

Indoor unit

Heat pump type


This system provides cooling, heating, automatic,
program dry, and fan operation modes.
Cooling only type
This system provides cooling, program dry, and
fan operation modes.

PRECAUTIONS FOR GROUP CONTROL


SYSTEM OR TWO REMOTE
CONTROLLER CONTROL SYSTEM
This system provides two other control systems
beside individual control (one remote controller
controls one indoor unit) system. Confirm the following if your unit is of the following control system
type.

Outdoor unit
Unit with
remote
controller

Group control system


One remote controller controls up to 16 indoor
units.
All indoor units are equally set.

Multi system

Indoor unit

Indoor unit

Outdoor unit
Unit with
remote
controller

Unit with
remote
controller

NOTE
If the unit you purchased is controlled by a wireless remote controller, also refer to the wireless
remote controllers operation manual.
If your installation has a customized control system,
ask your Daikin dealer for operation that corresponds to your system.

Two remote controllers control system


Two remote controllers control one indoor unit
(In case of group control system, one group of
indoor units)
The unit is individually operated.
NOTE
Contact your Daikin dealer in case of changing
the combination or setting of group control and
two remote controllers control system.

Names and functions of parts


Refer to figure 2 on page [1]
a

c
d
e
f
g
h
i
j
k

394

Indoor unit
Outdoor unit
The external appearance of the outdoor
unit varies depending on its capacity
class. The outdoor unit shown in the figure is for reference to indicate features.
Contact your Daikin Dealer and verify
which outdoor unit you have.
Remote controller
Inlet air
Discharged air
Air outlet
Air flow flap (at air outlet)
Refrigerant piping, connection electric wire
Drain pipe
Air inlet
The built-in air filter removes dust and dirt.
Drain pumping out device (built-in)
Drains water removed from the room during cooling.
Ground wire
Wire to ground from the outdoor unit to prevent electrical shocks.

Operation Manual

EDAU12-722

2. SAFETY CONSIDERATIONS
We recommend that you read this instruction manual carefully before use to gain full advantage of the
function of the air conditioner, and to avoid malfunction due to erroneous handling.
This air conditioner comes under the term appliances not accessible to the general public.
The precautions described below are WARNING and CAUTION. These are very important
precautions concerning safety. Be sure to
observe all of them without fail.
WARNING.. These are the matters with possibilities leading to serious consequences such as death or serious
injury due to erroneous handling.
CAUTION ... These are the matters with possibilities leading to injury or material damage due to erroneous
handling including probabilities
leading to serious consequences
in some cases.
After reading, keep this manual at a place
where any user can read at any time. Furthermore, make certain that this operation manual
is handed to a new user when he takes over
the operation.
WARNING
Avoid exposure of your body directly to the
cold air for a long time, or avoid excessive
exposure of your body to the cold air.
Otherwise, your physical condition may be deteriorated and/or your health may be ruined.
When the air conditioner is in abnormal conditions (smell of something burning, etc), unplug
the power cord from the outlet, and contact the
dealer where you purchased the air conditioner.
Continued operation under such circumstances
may result in a failure, electric shock, and fire.
Ask your dealer for installation of the air conditioner.
Incomplete installation performed by yourself may
result in a failure, a water leakage, electric shock,
and fire.
Ask your dealer for improvement, repair, and
maintenence.
Incomplete improvement, repair, and maintenance may result in a failure, a water leakage,
electric shock, and fire.
Do not insert your finger, a stick, etc., into the
air inlet, outlet, and fan blades.
A fan in high-speed running may result in injury.
For refrigerant leakage, consult your dealer.
When the air conditioner is to be installed in a
small room, it is necessary to take proper measures so that the amount of any leaked refrigerant
dose not exceed the limiting concentration even
when it leaks. If the refrigerant leaks exceeding

Operation Manual

Instruction

the level of limiting concentration, an oxygen deficiency accident may happen.


For installation of separately sold component
parts, ask a specialist.
Be sure to use the separately sold component
parts designated by our company.
Incomplete installation performed by yourself may
result in a failure, a water leakage, electric shock,
and fire.
Ask your dealer to move and reinstall the air
conditioner.
Incomplete installation may result in a failure, a
water leakage, electric shock, and fire.
The refrigerant in the air conditioner is safe
and normally does not leak. If the refrigerant
leaks inside the room, the contact with a fire of
a burner, a heater or a cooker may result in a
harmful gas.
Do not use the air conditioner until when a service
person confirms to finish repairing the portion
where the refrigerant leaks.

CAUTION
Do not use the air conditioner for other purposes.
Do not use the air conditioner for a special application such as the storage of foods, animals and
plants, precision machines, and art objects as
otherwise the deterioration of quality may result.
Do not remove the air outlet of the outdoor
unit.
The fan may get exposed and result in injury.
When the air conditioner is used in combination with burners or heaters, perform sufficient
ventilation.
Insufficient ventilation may result in an oxygen
deficiency accident.
Check and make sure that foundation blocks
are not damaged after a long use.
If they are left in a damaged condition, the unit
may fall and result in injury.
Neither place a flammable spray bottle near
the air conditioner not perform spraying.
Doing so may result in a fire.
To clean the air conditioner, stop operation,
and unplug the power cord from the outlet.
Otherwise, an electric shock and injury may
result.
Do not operate the air conditioner with a wet
hand.
An electric shock may result.
Do not use any fuse with improper capacity.
The use of piece of wire and whatnot may result
in a failure and fire.
Do not place a burner or heater at a place
directly exposed to the wind from the air conditioner.
Incomplete combustion of the burner or heater
may result.
Do not allow a child to mount on the outdoor
unit or avoid placing any object on it.
Falling or tumbling may result in injury.

395

Instruction

EDAU12-722

Do not expose animals and plants directly to


the wind from the air conditioner.
Adverse influence to animals and plants may
result.
Do not wash the air conditioner with water.
An electric shock may result.
Do not install the air conditioner at any place
where flammable gas may leak out.
If the gas leaks out and stays around the air conditioner, a fire may break out.
Be sure to install an earth leakage breaker.
Unless it is installed, an electric shock may result.
Be sure the air conditioner is electrically
grounded.
Do not connect the grounding conductor to a gas
pipe, water pipe, lightning arrester, and the
grounding conductor for a telephone.
Imperfect grounding work may result in an electric
shock.
Execute complete drain piping for perfect
drainage.
Incomplete piping may result in a water leakage.
The appliance is not intended for use by young
children or infirm persons without supervision.
Young children should be supervised to ensure
that they do not play with the appliance.

3. OPERATION RANGE
If the temperature or the humidity is beyond the following conditions, safety devices may work and the
air conditioner may not operate, or sometimes,
water may drop from the indoor unit.
COOLING
OUTDOOR
UNIT

INDOOR
TEMPERATURE

RS50 60
RKS25 35
50 60
RXS25 35
50 60

D
B 21 to 32

3MKS50
4MKS58 75
90
3MXS52
4MXS68 80

D
B 21 to 32

W 14 to 23
B

W 14 to 23
B

HUMIDITY

OUTDOOR
TEMPERATURE

80% or
below

D -10 to 46
B (-5)

80% or
below

D -10 to 46
B

RXS25 35
RXS50 60
3MXS52
4MXS68 80

396

INDOOR
TEMPERATURE
DB
DB
DB

10 to 30
10 to 30
10 to 30

4. INSTALLATION SITE
Regarding places for installation
Is the air conditioner installed at a well-ventilated place where there are no obstacles
around?
Do not use the air conditioner in the following
places.
a. Filled with much mineral oil such as cutting oil
b. Where there is much salt such as a beach
area
c. Where sulfured gas exists such as a hot-spring
resort.
d. Where there are considerable voltage
fluctuations such as a factory or plant
e. Vehicles and vessels
f. Where there is much spray of oil and vapor
such as a cookery, etc.
g. Where there are machines generating
electromagnetic waves.
h. Filled with acid and/or alkaline steam or vapor
Is a snow protection measure taken?
For details, consult your dealer.

Regarding wiring
All wiring must be performed by an authorized
electrician.
To do wiring, ask your dealer. Never do it by
yourself.
Make sure that a separate power supply circuit
is provided for this air conditioner and that all
electrical work is carried out by qualified personnel according to local laws and regulations.

Pay attention to running noises, too

WB

-15 to 20

DB

-14 to 24

Are the following places selected?


a. A place that can sufficiently withstand the
weight of the air conditioner with less running
noises and vibrations.
b. A place where the hot wind discharged from
the air outlet of outdoor unit and the running
noises.
Are you sure that there are no obstacles near
the air outlet of the outdoor unit?
Such obstacles may result in declined performance and increased running noises.
If abnormal noises occur in use, stop the operation of the air conditioner, and then consult
your dealer or our service station.

WB

-15 to 18

Regarding drainage of drain piping

DB

-14 to 21

WB

-15 to 15.5

Is the drain piping executed to perform complete drainage?


If proper drainage is not carried out from the out-

HEATING
OUTDOOR
UNIT

DB: Dry bulb temperature (C)


WB: Wet bulb temperature (C)
The setting temperature range of the remote controller is 16 C to 32 C.
The numerical value in a parenthesis shows the
operation range of the model for Australia.

OUTDOOR
TEMPERATURE
DB

-14 to 24

Operation Manual

EDAU12-722

Instruction

door drain pipes during air-conditioning operation, chances are that dust and dirt are clogged
in the pipe. This may result in a water leakage
from the indoor unit. Under such circumstances,
stop the operation of the air conditioner, and then
con sult your dealer or our service station.

5. NAME AND FUNCTION OF


EACH SWITCH AND DISPLAY
ON THE REMOTE
CONTROLLER
Refer to figure 1 on page [1]

ON/OFF BUTTON
Press the button and the system will start.
Press the button again and the system will
stop.
OPERATION LAMP (RED)
The lamp lights up during operation.
DISPLAY
(UNDER CENTRALIZED CONTROL)
When this display shows, the system is
UNDER CENTRALIZED CONTROL.
DISPLAY

(VENTILATION/AIR CLEANING)
This display shows that the total heat
exchange and the air cleaning unit are in
operation (These are optional accessories).
DISPLAY

(OPERATION MODE)
This display shows the current OPERATION
MODE. For cooling only type,
(Auto)
and
(Heating) are not installed.
DISPLAY TEST (INSPECTION/TEST
OPERATION)
When the INSPECTION/TEST OPERATION
BUTTON is pressed, the display shows the
system mode is in.
DISPLAY

(PROGRAMMED TIME)

This display shows the PROGRAMMED


TIME of the system start or stop.
DISPLAY
(SET TEMPERATURE)
This display shows the set temperature.

DISPLAY
(FAN SPEED)
This display shows the set fan speed.
DISPLAY
(AIR FLOW FLAP)
10
Refer to AIR FLOW DIRECTION ADJUST.
9

Operation Manual

DISPLAY
(TIME TO CLEAN AIR
11 FIL-TER)
Refer to HOW TO CLEAN THE AIR FILTER.
DISPLAY
(DEFROST)
12
Refer to DEFROST OPERATION".
NON-FUNCTIONING DISPLAY
If that particular function is not available,
pressing the button may display the words
NOT AVAILABLE for a few seconds.
13 When running multiple units simultaneously
The NOT AVAILABLE message will only be
appear if none of the indoor units is equipped
with the function. If even one unit is equipped
with the function, the display will not appear.
TIMER MODE START/STOP BUTTON
14
Refer to PROGRAM TIMER OPERATION.
TIMER ON/ OFF BUTTON
15
Refer to PROGRAM TIMER OPERATION

INSPECTION/TEST OPERATION BUTTON


16
This button is used only by qualified service
persons for maintenance purposes.
PROGRAMMING TIME BUTTON
17 Use this button for programming START and/
or STOP time.
TEMPERATURE SETTING BUTTON
18 Use this button for SETTING TEMPERATURE.
FILTER SIGN RESET BUTTON
Refer to HOW TO CLEAN THE AIR FILTER.
FAN SPEED CONTROL BUTTON
20 Press this button to select the fan speed,
HIGH or LOW, of your choice.
OPERATION MODE SELECTOR BUTTON
21
Press this button to select OPERATION MODE.
19

22

AIR FLOW DIRECTION ADJUST BUTTON


Refer to AIR FLOW DIRECTION ADJUST.

NOTE
For the sake of explanation, all indications are
shown on the display in figure 1 contrary to
actual running situations.

6. OPERATION PROCEDURE
Refer to figure 1 on page [1]
Operating procedure varies with heat pump type
and cooling only type. Contact your Daikin dealer
to confirm your system type.
To protect the unit, turn on the main power switch
6 hours before operation.

397

Instruction

EDAU12-722

If the main power supply is turned off during


operation, operation will restart automatically
after the power turns back on again.

COOLING, HEATING, AUTOMATIC, FAN,


AND PROGRAM DRY OPERATION
Operate in the following order.

OPERATION MODE SELECTOR

Press OPERATION MODE SELECTOR button several times and select the OPERATION MODE of your choice as follows.
COOLING OPERATION ........................
HEATING OPERATION .........................
AUTOMATIC OPERATION.....................

In this operation mode,COOL/HEAT


changeover is automatically conducted.
FAN OPERATION .................................

DRY OPERATION..................................

The function of this program is to decrease


the humidity in your room with the minimum
temperature decrease.
Micro computer automatically determines
TEMPERATURE and FAN SPEED.
This system dose not go into operation if the
room temperature is below 16 C.
Refer to figure 3 on page [1]
For cooling only type, COOLING , FAN and
DRY operation are able to select.

ON/OFF

Press ON/OFF button


OPERATION lamp lights up or goes off and the system starts or stops OPERATION.

[EXPLANATION OF HEATING OPERATION]


DEFROST OPERATION
As the frost on the coil of an outdoor unit
increase, heating effect decreases and the system goes into DEFROST OPERATION.
The indoor unit fan stops and the remote controller display shows
.
After 6 to 8 minutes (maximum 10 minutes) of
DEFROST OPERATION, the system returns to
HEATING OPERATION.

Regarding outside air temperature and heating capacity


The heating capacity of the air conditioner
declines as the outside air temperature falls.
In such a case, use the air conditioner in combination with other heating systems.

398

A warm air circulating system is employed, and


therefore it takes some time until the entire room
is warmed up after the start of operation.
An indoor fan runs to discharge a gentle wind
automatically until the temperature inside the air
conditioner reaches a certain level. At this time,
the remote controller displays
. Leave it
as it stands and wait for a while.
When the warm air stays under the ceiling and
your feet are cold, we recommend that you use a
circulator (a fan to circulate the air inside the
room). For details,consult your dealer.

ADJUSTMENT
For programming TEMPERATURE, FAN SPEED
and AIR FLOW DIRECTION, follow the procedure
shown below.

TEMPERATURE SETTING
Press TEMPERATURE SETTING button and
program the setting temperature.
Each time this button is pressed,setting
temperature rises 1 C.
Each time this button is pressed, setting temperature lowers 1 C.
The setting is impossible for fan operation.
NOTE
The setting temperature range of the remote controller is 16 C to 32 C.

FAN SPEED CONTROL


Press FAN SPEED CONTROL button.
High or Low fan speed can be selected.
Micro computer may sometimes control the fan
speed in order to protect the unit.

AIR FLOW DIRECTION ADJUST


Press the AIR FLOW DIRECTION ADJUST button
to adjust the air flow angle.

Up and down adjustment


The movable limit of the flap is changeable.
Contact your Daikin dealer for details.

Operation Manual

EDAU12-722

Instruction

Press the AIR FLOW DIRECTION ADJUST


button to select the air direction as following.
The AIR FLOW FLAP display
swings as shown left and the
air flow direction continuously
varies. (Automatic swing setting)

swing

Press the PROGRAMMING TIME button and


set the time for stopping or starting the system.
When this button is pressed, the time
advances by 1 hour.

Press AIR FLOW DIRECTION


ADJUST button to select the air
direction of your choice.
The AIR FLOW FLAP display
stops swinging and the air
flow direction is fixed (Fixed
air flow direction setting).

PROGRAMMING TIME

When this button is pressed, the time


goes backward by 1 hour.

TIMER ON/OFF

Press the TIMER ON/OFF button.


MOVEMENT OF THE AIR FLOW FLAP
For the following conditions, micro computer controls the air flow direction so it may be different from
the display.
Operation
mode
Operation
condition

Heating
When starting operation
When room temperature is higher
than the set temperature
At defrost operation
(Air is blown horizontally to prevent
the cool air from being blown
directly onto anyone in the room.)

Operation mode includes automatic operation.

PROGRAM TIMER OPERATION


Operate in the following order.
The timer is operated in the following two ways.
Programming the stop time (
) .... The system stops
operating after the set time has elapsed.
Programming the start time (
) .... The system starts
operating after the set time has elapsed.
The timer can be programmed a maximum of 72
hours.
The start and the stop time can be simultaneously programmed.

TIMER MODE START/STOP

Press the TIMER MODE START/STOP button several times and select the mode on
the display.
The display flashes.
For setting the timer stop ....
For setting the timer start ....

Operation Manual

The timer setting procedure ends.


The display
or
changes from flashing light to a constant light.
Refer to figure 4 on page [1]
NOTE
When setting the timer Off and On at the same
time, repeat the above procedure from 1 to 3
once again.
When the timer is programmed to stop the system
after 3 hours and start the system after 4 hours, the
system will stop after 3 hours and then 1 hour later
the system will start.
After the timer is programmed, the display shows
the remaining time.
Press the TIMER ON/OFF button once again to
cancel programming. The display vanishes.

7. OPTIMUM OPERATION
Observe the following precautions to ensure the
system operates.
Adjust the room temperature properly for a comfortable environment. Avoid excessive heating or
cooling.
Prevent direct sunlight from entering a room during cooling operation by using curtains or blinds.
Ventilate the room regularly.
Using the unit for long periods of time requires
attentive ventilation of the room.
Do not place items that might be damaged by
water under the indoor unit.
Water may condensate and drip if the humidity
reaches 80% or if the drain exit gets clogged.
Keep doors and windows closed. If the doors and
windows remain open, room air will flow out and
cause to decrease the effect of cooling and heating.

399

Instruction

EDAU12-722

Do not place other heaters directly below the


indoor unit.
They may deform due to the heat.
Never place objects near the air inlet and the air
outlet of the unit. It may cause deterioration in the
effect or stop in the operation.
Turn off the main power supply switch when it is
not used for long periods of time. When the main
power switch is turned on, some watts of electricity is being used even if the system is not operating. Turn off the main power supply switch for
saving energy. When reoperating, turn on the
main power supply switch 6hours before operation for smooth running (Refer to MAINTENANCE).
When the display shows
(TIME TO
CLEAN AIR FILTER), ask a qualified service person to clean the filters (Refer to MAINTENANCE).

Fig. 1

2. Detach the air filter


Pull the hook of the air filter out diagonally downward, and remove the filter.
Fig. 2

8. MAINTENANCE
(FOR SERVICE PERSONNEL)
ONLY A QUALIFIED SERVICE PERSON IS
ALLOWED TO PERFORM MAINTENANCE
IMPORTANT!
BEFORE OBTAINING ACCESS TO TERMINAL DEVICES, ALL POWER SUPPLY CIRCUITS MUST BE INTERRUPTED
To clean the air conditioner, be sure to stop operation, and turn the power switch off. Otherwise,
an electric shock and injury may result.
Do not wash the air conditioner with water
Doing so may result in an electric shock.
Be careful with a scaffold or staging
Caution must be exercised because of work at a
high place.

HOW TO CLEAN THE AIR FILTER


Clean the air filter when the display shows
(TIME TO CLEAN AIR FILTER).

It will display that it will operate for a set amount of


time.
Increase the frequency of cleaning if the unit is
installed in a room where the air is extremely contaminated.
If the dirt becomes impossible to clean, change the
air filter (Air filter for exchange is optional)

3. Clean the air filter.


Use vacuum cleaner A) or wash the air filter with
water B).
A) Using a vacuum cleaner

B) Washing with water


When the air filter is very dirty, use
soft brush and neutral detergent.
Remove water and dry in the shade.
NOTE
Do not wash the air conditioner with hot water of
more than 50C, as doing so may result in discoloration and/or deformation.
Do not expose it to fire, as doing so may result in
burning.
4. Fix the air filter
(1) Hook the air filter to a protrusion on the suction grille.
(2) Push the lower part of the air filter onto the
protrusion at the lower part of the suction
grille, and fix the air filter there.
Fig. 3

1. Open the suction grille.


Push it downward slowly while pressing horizontally the buttons provided on two spots.
(Follow the same procedure for closing).

400

Operation Manual

EDAU12-722

5. Shut the suction grille.


Refer to item No.1.
6. After turning on the power, press FILTER
SIGN RESET button.
The TIME TO CLEAN AIR FILTER display vanishes.

Instruction

Directly apply the type of detergent used for


cleaning ventilation fans or ovens, wait 10 minutes, and then rinse with water.
5. Fix the air filter.
Refer to HOW TO CLEAN THE AIR FILTER.
(Refer to Fig. 3)

HOW TO CLEAN AIR OUTLET AND OUTSIDE PANELS

6. Fix the suction grille.


Refer to item No. 2.

Clean with soft cloth.


When it is difficult to remove stains, use water or
neutral detergent.

7. Shut the suction grille.


Refer to item No. 1.

NOTE
Do not use gasoline, benzene, thinner, polishing
powder, liquid insecticide. It may cause discoloring or warping.
Do not let the indoor unit get wet. It may cause an
electric shock or a fire.
Do not use water or air of 50C or higher for
cleaning air filters and outside panels.

HOW TO CLEAN THE SUCTION GRILLE


1. Open the suction grille.
Push it downward slowly while pressing horizontally the buttons provided on two spots. (Follow
the same procedure for closing.)
Fig. 4

START UP AFTER A LONG STOP


Confirm the following
Check that the air inlet and outlet are not
blocked. Remove any obstacle.
Check if the earth is connected.
Might there be a broken wire somewhere?
Contact your dealer if there are any problems.

Clean the air filter and outside panels


After cleaning the air filter, make sure to attach it.
Turn on the main power supply switch
The display on the remote controller will be
shown when the power is turned on.
To protect the unit, turn on the main power switch
at least 6 hours before operation.

WHAT TO DO WHEN STOPPING THE SYSTEM FOR A LONG PERIOD


Turn on FAN OPERATION for a half day and dry
the unit.
Refer to 6.OPERATION PROCEDURE.

2. Detach the suction grille.


Open the suction grille 45 degrees and lift it
upward.
Fig. 5

Cut off the power supply.


When the main power switch is turned on, some
watts of electricity is being used even if the system is not operating.
Turn off the main power supply switch for saving
energy.
The display on the remote controller will vanish
when the main power switch is turned off.
Clean the air filter and the exterior.
Be sure to replace the air filter to its original place
after cleaning. Refer to MAINTENANCE.

9. NOT MALFUNCTION OF THE


AIR CONDITIONER
3. Detach the air filter.
Refer to HOW TO CLEAN THE AIR FILTER.
(Refer to Fig. 2)
4. Clean the suction grille.
Wash with a soft bristle brush and
neutral detergent or water, and dry
throughly.
When very grimy

Operation Manual

The following symptoms do not indicate air conditioner malfunction


I. THE SYSTEM DOES NOT OPERATE
The system does not restart immediately after
the ON/OFF button is pressed.
If the OPERATION lamp lights, the system is in
normal condition.
It does not restart immediately because a safety
device operates to prevent overload of the sys-

401

Instruction

tem. After 3 minutes, the system will turn on


again automatically.
The system does not restart immediately
when TEMPERATURE SETTING button is
returned to the former position after pushing
the button.
If the OPERATION lamp lights, the system is in
normal condition.
It does not restart immediately because a safety
device operates to prevent overload of the system. After 3 minutes, the system will turn on
again automatically.
The system does not start when the display
shows
(UNDER CENTRALIZED
CONTROL) and it flashes for few seconds
after pressing an operation button.
This is because the system is under centralized
control. Flashes on the display indicates that the
system cannot be controlled by the remote controller.
The system does not start immediately after
the power supply is turned on.
Wait one minute until the micro computer is prepared for operation.
The outdoor unit is stopped
This is because the room temprerature has
reached the set temprerature. The indoor unit
switches to fan operation.

II. The display shows


(UNDER CENTRALIZED CONTROL) and the unit operates
in a mode different to what is shown on the
remote controller display.
When using a unit in a multi system, the operation condition of that unit is controlled by a micro
computer as described below, according to the
operation condition of other indoor units connected to the system.
If the operation mode does not match other
indoor units that are already running, the indoor
unit will assume the STANDBY state (the fan is
stopped and the air flow flap is positioned horizontally).
If HEATING mode is set together with COOLING, DRY or FAN mode, the above mentioned
condition will occur.
NOTE
Normally, the operation mode in the room where
the unit is first run is given priority, but the following situations are exceptions, so please keep this
in mind.
a. If the operation mode of the first room is FAN
Mode, then using Heating Mode in any room
after this will give priority to heating. In this situation, the air conditioner running in FAN
Mode will go on standby.
b. With the Priority Room Setting active.
Contact your Daikin dealer for the operation
that corresponds to your system.
If the total capacity of operating indoor units
exceeds the limit, the indoor unit will assume the
STANDBY state (FAN and AIR FLOW DIREC-

402

EDAU12-722

TION will be left as set). (This only applies to


cooling only type.)
If another indoor unit commences a HEATING
operation after this indoor unit is running in
COOLING mode, this indoor unit may switch to
DRY operation (fan on low, air flow flap set at horizontal).
III.The fan speed is different from the setting.
Pressing the fan speed control button does
not change the fan speed.
When the room temperature reaches the set
temperature in heating mode, the power supply
from the outdoor unit is stopped and the indoor
unit will operate on the low fan setting. (If using
the multi system, the fan will alternate between
off and low.)
This is to prevent the cool air from being blown
directly onto anyone in the room.
IV. AIR BLOW DIRECTION IS NOT AS SPECIFIED.
Actual air blow direction is not as shown on
the remote contoller.
Automatic swing setting does not work.
Refer to AIR FLOW DIRECTION ADJUST.
V. WHITE MIST COMES OUT OF A UNIT
When humidity is high during cooling operation (In oily or dusty places)
If the inside of an indoor unit is extremely contaminated, the temperature distribution inside a
room becomes uneven. It is necessary to clean
the inside of the indoor unit. Ask your Daikin
dealer for details on cleaning the unit. This operation requires a qualified service person.
When the system is changed over to HEATING OPERATION after DEFROST OPERATION.
Moisture generated by DEFROST becomes
steam and exists.
VI.NOISE OF AIR CONDITIONERS
A ringing sound after the unit is started.
This sound is generated by the temperature regulator working.
It will quiet down after about a minute.
A continuous flow Shuh sound is heard when
the systems is in COOLING or DEFROST
OPERATION.
This is the sound of refrigerant gas flowing
through both indoor and outdoor units.
A Shuh sound which is heard at the start or
immediately after the stop of operation or
which is heard at the start or immediately after
the stop of DEFROST OPERATION.
This is the noise of refrigerant caused by flow
stop and flow change.
A continuous flowing sound "Shah"or a trickling sound "Jyuru Jyuru"are heard when the
system is in COOLING OPERATION or at a
stop.
The noise is heard when the drain pump is in
operation.

Operation Manual

EDAU12-722

Instruction

A Pishi-pishi squeaking sound is heard when


the system is in operation or after the stop of
operation.
Expansion and contraction of plastic parts
caused by temperature change makes this noise.
VII.DUST FROM THE UNITS
Dust may blow out from the unit after starting
operation from long resting time.
Dust absorbed by the unit blows out.
VIII.THE UNITS GIVE OFF ODORS
The unit absorbs the smell of rooms, furniture,
cigarettes, etc., and then emits them.
IX.THE LIQUID CRYSTAL OF THE REMOTE
CONTROLLER SHOW

It happens immediately after the main power


supply switch is turned on.
This shows that the remote controller is in normal condition.
This continues temporary.

10. TROUBLE SHOOTING


I. If one of the following malfunctions occurs,
take the measures shown below and contact
your Daikin dealer.
The system must be repaired by a qualified service
person.
WARNING
When the air conditioner is in abnormal conditions (smell of something burning, etc),
unplug the power cord from the outlet, and
contact your dealer
Continued operation under such circumstances
may result in a failure, electric shock, and fire.
If a safety device such as a fuse, a breaker, or an
earth leakage breaker frequently actuates, or
ON/OFF switch does not properly work.
Measure: Turn off the main power switch
If water leaks from unit.
Measure: Stop the operation.
If the display
(INSPECTION), UNIT No.,
and the OPERATION lamp flash and the MALFUNCTION CODE appears.
OPERATION lamp

Measure: Notify and inform the model name and


what the malfunction code indicates
to your Daikin dealer.
II. If the system does not properly operate
except for the above mentioned case, and
none of the above mentioned malfunctions is
evident, investigate the system according to
the following procedures.
1. If the system does not operate at all.
Check if there is a power failure.
Wait until power is restored. If power failure
occurs during operation, the system automatically restarts immediately after the power supply
recovers.
Check if the fuse has blown or breaker has
worked.
Change the fuse or set the breaker.

2. If the system stops operating after operating


the system.
Check if the air inlet or outlet of outdoor or indoor
unit is blocked by obstacles.
Remove the obstacle and make it well-ventilated.
Check if the air filter is clogged.
Ask a qualified service person to clean the air filters (Refer to MAINTENANCE).
3. The system operates but it does not sufficiently cool or heat.
If the air inlet or outlet of the indoor or the outdoor
unit is blocked with obstacles.
Remove the obstacle and make it well-ventilated.
If the air filter is clogged.
Ask a qualified service person to clean the air filters (Refer to MAINTENANCE).
If the set temperature is not proper (Refer to
ADJUSTMENT).
If the FAN SPEED button is set to LOW SPEED
(Refer to ADJUSTMENT).
If the air flow angle is not proper (Refer to AIR
FLOW DIRECTION ADJUST).
If the doors or the windows are open.
Shut doors or windows to prevent wind from coming in.
If direct sunlight enters the room (when cooling).
Use curtains or blinds.
When there are too many inhabitants in the room
(when cooling).
Cooling effect decreases if heat gain of the room
is too large.
If the heat source of the room is excessive (when
cooling).
Cooling effect decreases if heat gain of the room
is too large.

UNIT No.

INSPECTION
display

L H

INDOOR UNIT No. in which


a malfunction occurs
MALFUNCTION CODE

3P083810-4M

Operation Manual

403

Instruction

404

EDAU12-722

Operation Manual

EDAU12-722

Part 5
Options
1. Optional Accessories ..........................................................................406
1.1 Option List ............................................................................................406
1.2 Installation Manual ...............................................................................408

Options

405

Optional Accessories

EDAU12-722

1. Optional Accessories
1.1

Option List

1.1.1

Indoor Units

Wall Mounted Type


FTXS20D
FTXS25/35E

Option Name

Centralized Control Board-up to 5 Rooms

Wiring Adaptor for Time Clock/Remote Control 2


(Normal Open Pulse Contact / Normal Open Contact)

KRC72
KRP413A1S

1
1

Central Remote Controller

Unified ON/OFF Controller

Schedule Timer

Interface Adaptor for Room Air Conditioner

Titanium Apatite Photocatalytic Air-purifying Filter


(without Frame)

Remote Controller Loss Prevention with the Chain

FTXS50/60/71F

DCS302CA61
DCS301BA61

DST301BA61
KRP928B2S
KAF970A46

KAF952B42
KKF917A4

1 Wiring adaptor is also required for each indoor unit.


2 Time clock and other devices ; obtained locally.
Duct Connected Type
Option Name

FDXS25-50C

Centralized Control Board-up to 5 Rooms

Wiring Adaptor for Time Clock/Remote Control 2


(Normal Open Pulse Contact / Normal Open Contact)

FDXS60C

CDXS25/35E

KRC72
KRP413A1S

1
1

DCS302CA61

Central Remote Controller

Unified ON/OFF Controller

Schedule Timer

Interface Adaptor for Room Air Conditioner

KRP928B2S

Suction Grille

KDGF19A45

DCS301BA61

DST301BA61

Insulation Kit for High Humidity

Remote Controller Loss Prevention with the Chain

KDT25N50

KDT25N63

KDT25N32

KKF917A4

1 Wiring adaptor is also required for each indoor unit.


2 Time clock and other devices ; obtained locally.
Floor / Ceiling Suspended Dual Type
Option Name

FLXS25/35/50/60B

Centralized Control Board-up to 5 Rooms

Wiring Adaptor for Time Clock/Remote Control 2


(Normal Open Pulse Contact / Normal Open Contact)

KRC72
KRP413A1S

1
Unified ON/OFF Controller 1
Schedule Timer 1

Interface Adaptor for Room Air Conditioner

KRP928B2S

Photocatalytic Deodorizing Filter with Frame

KAZ917B41

Photocatalytic Deodorizing Filter without Frame

KAZ917B42

Air Purifying Filter with Frame

KAF925B41

10

Air Purifying Filter without Frame

KAF925B42

11

Remote Controller Loss Prevention with the Chain

KKF917A4

3
4

Central Remote Controller

DCS302CA61
DCS301BA61
DST301BA61

1 Wiring adaptor is also required for each indoor unit.


2 Time clock and other devices ; obtained locally.

406

Options

EDAU12-722

Optional Accessories

Floor Standing Type


Option Name

FVXS35/50F

KRC72

Centralized Control Board-up to 5 Rooms

Wiring Adaptor for Time Clock/Remote Control 2


(Normal Open Pulse Contact / Normal Open Contact)

Central Remote Controller

Unified ON/OFF Controller

Schedule Timer

KRP413A1S

1
1

DCS302CA61
DCS301BA61

DST301BA61

Interface Adaptor for Room Air Conditioner

KRP928B2S

Titanium Apatite Photocatalytic Air-purifying Filter


(without Frame)

KAF968A42

Remote Controller Loss Prevention with the Chain

KKF910AA4

1 Wiring adaptor is also required for each indoor unit.


2 Time clock and other devices ; obtained locally.

Ceiling Mounted Cassette Type


Option Name

FFQ25/35/50/60B

Decoration Panel (required)

BYFQ60BW1

Sealing Member of Air Discharge Outlet

KDBHQ44B60

Panel Spacer

KDBQ44B60A

Fresh Air Intake Kit

Long-Life Filter

Direct Installation Type

KDDQ44X60
KAFQ441B60

Wired Type

BRC1C61

Remote Controller
(required)

Central Remote Controller

DCS302CA61

Unified ON/OFF Controller

DCS301BA61

Schedule Timer

DST301BA61

10

Adaptor for Wiring

Wireless
Type

Cooling Only

BRC7E531W7

Heat Pump

BRC7E530W7

11

Adaptor for External ON/OFF and Monitoring

12

Installation Box for Adaptor PCB

13

Remote Sensor

14

Interface Adaptor for SkyAir Series

KRP1B57

KRP4A53
KRP1B101
KRCS01-1
DTA112BA51

1 Installation box for adaptor PCB(KRP1B101) is necessary.

1.1.2

Outdoor Units
Option Name
1

Air Direction Adjustment Grille

Drain Plug

3MXS52E
3MXS68E

4MXS80E
KPW945A4

KKP937A4

KKP945A4

1 5 pieces / 5units
2 1 set / 1 unit

Options

407

Optional Accessories

EDAU12-722

1.2

Installation Manual

1.2.1

KRP413A1S
Safety Precautions

Read these safety precautions carefully before installing the unit, and be
sure to install the unit properly.
This manual classifies precautions to the user into the following two
categories. These warnings and cautions are for your safety. Follow them.
WARNING

Faulty installation can result in death or serious injury

CAUTION

Faulty installation can result in serious injury


or other serious consequences.

Below is a key to symbols used in this manual.


Be sure to follow instructions.
Be sure to perform grounding work.
Never attempt.

After installation is complete, test the unit to confirm that it is working


properly, and instruct the owner its proper use.

WARNING
Installation should be left to the dealer from whom you purchased the unit, or
another qualified professionals.
Install the unit securely according to the installation manual. Faulty installation
may lead to electric shock or fire.
Be sure to use the supplied or specified parts. Using other parts may lead to
electric shock or fire.
Install the unit securely in a location that will support its weight. If installed in a
poor location or improperly installed, the unit may not work as intended.
For electrical work, follow local electric standards and the installation manual.
Faulty installation may lead to fire or electric shock.
Do not bundle the power cord, or attempt to extend it by splicing it with another
cord or by using an extension cord. Do not place any other load on the power
circuit used for the unit. Improper wiring may lead to electric shock, heat
generation or fire.
Use dedicated wiring for all electrical connections, and be sure to arrange the
wiring so that force applied to the wiring will not damage the terminals. Poor
wiring or installation may cause electric shock, heat generation or fire.

1. Functions and Features


On/Off setting
Switching between Instantaneous Contact/Normal Contact
Connection with five-room central controller (KRC72 for oversea model)
Connection with fan coil remote controller
Automatic reset after power failure
Output of normal operation signals/malfunction signals

2. Field Wiring
For interconnecting wiring, use Daikin KDC100A12 cable (not supplied) or
other similar cable. The cable should have the specifications shown below.
Optional cable KDC100A12 (without connectors)
Specifications:
0.2 mm2 4 core (sheathed)
Outer diameter: 5.3
Length:
100 m
Colour:
Grey
Other cable (commercially available)
Outer dia.

Remarks

Cable for instrumentation (IPVV) 0.3 mm2 4-core

Item

7.2 mm

Hard sheath

Microphone cord (MVVS) 0.3 mm2 4-core

8.0 mm

Microphone cord (MVVS) 0.2 mm2 4-core

6.5 mm

Microphone cord (MVVS) 0.15 mm2 4-core

4.8 mm

Shielded

Intercom cable 0.65 mm2 dia. 4-core


PVC jumper wire (TJVC) (from 0.5 mm dia. 4 pcs.)

Not sheathed

Note 1: Keep any wiring for the control unit away from the power cord to prevent
electrical noise.
Note 2: Do not use cables shown above for power cord, inter-unit cord/cable or
power cord for lamps.

CAUTION
Before installation, unplug the air conditioner to ensure safety. Failure to do so
may cause electric shock.
Static electricity may damage electric components. Before connecting cables
and communication lines, and operating the switches, be sure to discharge any
electrical charge from your body (by, for example, touching the earth line)
Do not install the unit in a location where it may be exposed to flammable
gases. If gas leaks and build up around the unit, it may catch fire.
Do not place the wiring close to the power cord, inter-unit cable, or pipes which
generate noise. Treat the wiring with care.

408

Options

EDAU12-722

Optional Accessories

Installation
This product is available in two types. The KRP413A1S KRP413AA1S is for installation in a case independent of the indoor unit, and
the KRP413A1 is for installation within the indoor unit.

1. KRP413A1S KRP413AA1S
1

3. Attaching Adaptor Case Assy (for KRP413A1S KRP413AA1S)

Installation diagram

1
Adaptor case

Indoor unit PCB

Using the screws (to mount on a wall, etc.)

Use the 3 supplied screws to attach the case assy .

Adaptor case

S21

Indoor unit
wiring

Local wiring or
power cord, etc.

Install the adaptor case assy as close to the indoor unit as possible.
Removing case front
Case front

Components

Adaptor case assy


(Adaptor (PCB) is attached in the adaptor case.)

Wiring (approx. 0.8 m)

Screw
Adaptor PCB
Screw cover

Accessories
Binding band (4 pcs.)
Securing tape for attaching to the indoor unit (2 sets)
Screws for attaching the adaptor case (4 pcs.)
Screws for attaching to the wall (3 pcs.)

Remove the screw cover, one of the screws


and then the case front.
Attach the case back to the surface by
tightening the screws through the screw
holes (one round hole, two long holes).
After connecting the cables (refer to the following sections), replace the
case front. Be careful not to damage the wiring in the case.
Press in so that the prong catches
the case back.

Installation manual

Wiring

2. KRP413A1
For this type, install the adaptor PCB within the indoor unit. The method of
installation and connection vary depending on the model of the air
conditioner. See your air conditioner installation manual for details.

Screw

Screw cover

Components
Adaptor PCB

Installation manual

Wiring (approx. 0.25 m)

Using securing tape (to attach on the indoor unit)

Attach the adaptor case with the supplied securing tape.


Remove the case front (as for mounting on a wall).
After connecting the cables (see the following sections), replace the
case front. It can be screwed to the case back from the rear with the
four supplied screws.
Be careful not to damage the wiring in the case.
Attach the hook side (loop side) of the included securing tape to the rear
surface of the HA case, then attach the loop side (hook side) to the top of
the air conditioner unit spaced at the same intervals.

Securing tape
Hook side (loop side)

Securing tape
Loop side (hook side)
Indoor unit

To prevent the adaptor case assy from falling, do not use the securing
tape for attaching it to a wall or other surface.

Options

409

Optional Accessories

EDAU12-722

Wiring
1. Wiring

4. Connection with Remote Controller

Connect one end of the wiring to connector S21 of the PCB in the
indoor unit.
Connect the other end of the wiring to connector S6 of the adaptor
PCB.
Connect field wiring according to the functions assigned to each
connection terminal of the adaptor PCB.
Secure all wires.

Example connections with three kinds of remote controllers are shown


bellow.
Note: These connections cannot be used in combination.

Generic remote controller

Set SW1-1 to Off and select Operation Mode 1.


SW1

Securing wires in the adaptor case assy (for KRP413A1S KRP413AA1S)

ON
OFF

Fasten with a tie-wrap so that wires will not come loose even if pulled.
If the wire protrudes from
this side, cut the cut-off
section of the case front.

<Instantaneous Contact>
1

On/Off

2
1

Off

Inter unit
cable (field wiring)
Tie-wrap
(to prevent the wires from coming loose)

2. Automatic Reset After Power Failure

1
2
1

On

This PCB stores the following data in the event of a power failure
(common features).
On/Off (see Note 1)
Operation modes
Temperature setting
Air flow rate
On/Off status of remote controller

Power On/Off cannot be controlled


from the units remote controller.
When power is restored after a
power failure in this mode, On or
Off is determined according to
the current settings of the remote
controller.

Operation

Securing wires in the indoor unit (for KRP413A1)

S
1

S
2

Five-room central controller (KRC72)

Set SW1-1 to Off and select Operation Mode 1.


The remote controller most recently used takes precedence.
SW1
ON

Five-room central
controller

(Note 1 When SW1-2 is in Off mode, the unit will not be activated.)

OFF
1

3. Monitor Signal Output (normal operation and malfunction)

Terminal
blocks A to E

Maximum length of the wiring is 100 m.

1 S
2 4

3
2

1 S
2 1

Monitor signal output for LED


Locally procured parts
1

R
D

LED

Item Manufacturer

S
4

Max 100 m

S
2

<Normal Contact>

The method for securing wire varies depending on the model of the air
conditioner. See your air conditioner installation manual for details.

The remote controller most


recently used (local or air
conditioner) takes precedence.
Use a remote controller with a
pulse width of 100 msec or
more.

S
1

LED

Toshiba

Rohm

Type
TLG208 (green)
TLR208 (red)
1S2473
510 ohm 1/4W

Monitor signal output (normal operation and


malfunction)using external relay contacts

Fan coil remote controller

Set SW1-1 to On and select Operation Mode 2.


Most settings (power On/Off, air flow rate, mode change) cannot be
made using the air conditioners remote controller.
When power is restored after a power failure in this mode, On or Off is
determined according to the current settings of the remote controller.
When the Cooling /Heating mode is changed, use the air conditioners
remote controller to adjust the temperature.
SW1
ON

S
8

DC12V

S
5

L1

2
3

L2

OFF

: Operation light
: Malfunction light

S
1

H M L OFF

(+)
MR1

()

L1

MR1
MR2

()

MR2

External power
supply for light

L2

1
2

Max 100 m

Field supplied parts

Field procured parts (Recommended external relay contacts)


Manufacturer

410

Type

Coil rated voltage

Fan coil remote controller

Omron

MY relay

12 V DC

160 ohm 10%

HC relay

12 V DC

160 ohm 10%

1 S
3

On (When heating)

Coil resistance

Matsushita

S
2

Off
(When cooling)

Cooling/heating switch

Options

EDAU12-722

Optional Accessories

Test Operation and Confirmation


1. When the System is Not Working
Is the air conditioner working properly?
Are the connectors of the wiring properly connected?
Are the remote controller and field wiring properly connected?
Are all switch settings correct?
If there is nothing apparently wrong, conduct a diagnostic check using the following procedure.
Diagnostic check
Defect in adaptor PCB.
Defect in wiring.
Defect in indoor units PCB.
Transmission error (between remote controller and indoor unit)

START

Is the CPU Normal light


for the remote controllers
PCB flashing?

No

Yes

Is 12 V DC being supplied
to No. 4 and No. 5 on S6 of the
remote controllers PCB?

No

Yes

Is 12 V DC being supplied
to No. 4 and No. 5 on S21
of the indoor unit?

No

Yes

5
Is the malfunction light
of the remote
controllers PCB on?

No

Yes
OR

2. Switch Settings and Connection Terminals

1
2
1
2
1
2
1
2

S
4
S
1
S
2
S
3

Selecting the operation


mode

OFF
ON

Operation mode 2 (Used with fan coil remote controller settings)

OFF

Always Off

SW1-2

Selecting On/Off when


power is restored after
a power failure

ON

Off if operation was in Off mode before power failure; On if operation was in
On mode before power failure

S 1
8 2
1
S 2
5
3

Instantaneous contact
SW1-1: OFF
(Operation mode 1)

SW1
1
2
OFF ON

S6

Normal contact

S1 (1) - S2 (1)

OPEN

CLOSE

S1 (1) - S1 (2)

Pulse input
On/Off switching

OPEN, Not activated


CLOSE, Activated

S1

S2 (2), S3

S2

S1, S2 OPEN

S3

S1 (1) - S1 (2) CLOSE

On, airflow: L tap

S1 (1) - S2 (1) CLOSE

On, airflow: M tap

S1 (1) - S2 (2) CLOSE

On, airflow: H tap

S3 (With the remote


controller only)

CLOSE, Heating

SW1-1: ON
(Operation mode 2)

CPU normal operation monitor


(Flashes when the operation is normal.)

Operation mode 1 (Used with the exception of fan coil remote controller settings)

SW1-1

S4
S5

(1) - (2)

Not activated

OPEN, Cooling

Voltage on (DC12 V), normal operation light output

(1) - (2)

Normal operation light output (power for light required)

(1) - (3)

Malfunction light output (power for light required)

S6 connector
S8

Not used

(+) - ()

Connect with connector S21 on the PCB of the indoor unit


Relay DC 12 V power supply terminal (Field supplied parts)

2P031616-1B

Options

411

Optional Accessories

1.2.2

EDAU12-722

KRP928B2S
1.Overview, Features and Compatible Models

Safety Precautions

This kit is the interface required when connecting the central controller and a Daikin Room Air
Conditioner. Use of the central controller makes it possible to perform the following monitoring
and operations. It is compatible with room air conditioners which have an HA connector S21.

Read these Safety Precautions carefully to ensure correct installation.


This manual classifies precautions into WARNING and CAUTION.

1.Run / stop for the central controller and wired remote controller, operating mode
selection, and temperature can be set.
2.The operating status, any errors, and the content of those errors can be monitored
from the central controller and wired remote controller.
3.Run / stop for the central controller and wireless remote controller, operating mode
selection, and the temperature setting can be limited by the central controller.
4.Zone control can be performed from the central controller.
5.The unit can remember the operating status of the air conditioner before a power
outage and then start operating in the same status when the power comes back
on.
6.Card keys, operating control panels, and other constant / instantaneous
connection-compatible equipment can be connected.
7.The Operating / error signals can be read.
8.HA JEM-A-compatible equipment can be connected.
9.The indoor temperature can be monitored from the Ve-up controller.

WARNING : Failure to follow WARNING is very likely to result in such grave


consequences as death or serious injury.

CAUTION : Failure to follow CAUTION may result in serious injury or


property damage, and in certain circumstances, may result in
a grave consequence.

Be sure to follow all the precautions below ; they are all important for
ensuring safety.
WARNING
Installation should be left to the dealer or another qualified professional.
Improper installation by yourself may cause malfunction, electrical shock, or fire.

Install the set according to the instructions given in this manual.


Incomplete or improper installation may cause malfunction, electrical shock, or fire.

Precaution
1.When reading the Operating / error signals, a separate external power source
(DC 12V) is needed.
2.A separate timer power source (DC 16V) is needed when using the schedule
timer independently, and not in conjunction with other central controllers.
3.The range of temperatures that can be set from the central controller is 18C to
32C in cooling and 14C to 28C in heating.
4.Fan operation cannot be selected from the central controller or wired remote controller.
5.Group control (i.e., control of multiple indoor units with a single remote controller) is
not available.
6.Monitoring is not available of the thermo status, compressor operating status,
indoor fan operating status, electric heater, or humidifier operating status.
7.Forced thermo off, filter sign display and reset, fan direction and speed settings,
air conditioning fee management, energy savings instructions, low-noise
instructions, and demand instructions cannot be made.

Be sure to use the standard attachments or the genuine parts.


Use of other parts may cause malfunction, electrical shock, or fire.

Disconnect power to the connected equipment before starting installation.


Failure to do so may cause malfunction, electrical shock, or fire.

CAUTION
An earth leakage circuit breaker should be installed.
If the breaker is not installed, electrical shock may occur.

Do not install the set in a location where there is danger of exposure to


inflammable gas.
Gas accumulated around the unit at the worst may cause fire.

2.Component Parts and Separately-Sold Parts which are Required

To prevent damage due to electrostatic discharge, touch your hand to a


nearby metal object (doorknob, aluminum sash, etc.) to discharge static
electricity from your body before touching this kit.

This kit includes the following components. Check to ensure that none of
these are missing.

Static electricity can damage this kit.

Qty

Parts
Kit assy
PCB is in the housing.

Lay this cable separately from other power cables to avoid external
electrical noises.

After installation is complete, test the operation of the PCB set to check
for problems, and explain how to use the set to the end-user.

Screw cover

Parts

Qty

Connection harness (about 1.6m)

1set

Mounting screws

3pcs.

Binding band

1pc.

Installation manual

1set

3.Names of Parts and Electric Wiring


<Wiring procedure>

Lower group number


switch (SW1)

Room air conditioner indoor unit

Service monitor (LED1: green)


When the CPU is working
properly, the LED flashes.

Upper group number


switch (SW2-1to 3)
Operation when recovering
from a power outage mode
switch (SW2-4)

Japanese unit / Overseas unit


Setting switch (SW3-3)

DAIKIN

Momentary contact / constant contact


Selection switch (SW3-2)

OFF

SW1

SW2
LED1

Supplied connection harness

SW3
S6
Tes1

S1
S16

Cable available field supply


(See the installation manual of
the central remote controller)

F1

S8

Central controller equipment


DCS302 Series
DCS301 Series
DCS601 Series
DST301 Series
KRC65, KRC72,
KDC100A10, and KDC101B
Series cannot be connected.
In case that a central remote
controller is connected

412

S5

Forced stop
Settings switch (SW3-1)
Power supply terminal (S8)
Connect an external DC 12V power
supply only when reading the
Operating / error display.

S19

F2

A cable field supply

Non polarity
Included in the Drain
Up Kit.

OFF

1234

1 2 3 4 ON

ON

1 1234

To HA connector (S21)

Once the switches are set and


the wiring complete, secure the
case using the included
screws.

A cable field supply

Separately sold remote control code (quadplex)


KRCW101A Series

Tele-con (Field supply)

Remote controller
BRC944 Series

Card key
(Field supply)
Operating control panel
(Field supply)

Operating monitoring
equipment
(Field supply)

The adapter included with the


remote controller is not used.

In case that the device coping


with HA JEM-A is connected

Connecting a Wired
Remote Controller

Connecting a Momentary / constant


Contact Input Equipment

Reading the Operating / error Display

Options

EDAU12-722

4.Switch Settings

5.Control Codes

Turn the power on after all the switches have been set.
Settings made while the power is on are invalid.

When using a central remote controller, the operating codes can be used to limit
operation from wireless remote controllers.
: permitted; : prohibited

ON

Automatic operation is available from the central controller.

(2) Group number settings (SW1 and SW2-1 to SW2-3)


Set these when using the central controller. (Set to the
than one unit to the same number.

side.) Do not set more

However, these settings do not need to be made when using the schedule timer
independently.
(The settings are needed when used in conjunction with another DCS Series
central controller.)
In this case, the schedule timer performs an auto address after the power is turned
on, so new group numbers are automatically set. Settings made using the switches
will be overwritten.
SW2 Upper
setting group NO.
1 1 2 3

Lower
SW1
setting group NO.
1 1 2 3 4

1
0

Lower
SW1
setting group NO.
1 2 3 4

0 0

0 8

0
1 2 3

1 2 3 4

2
1 2 3

1 2 3 4

1 2 3

1 2 3 4

1 2 3 4

1 2 3

1 2 3 4

1 2 3 4

1 2 3 4

1 2 3 4

1 2 3 4

1 3

0 6

1 5

(3) Settings when recovering from a power outage (SW2-4)


This selects whether to restart operation when the power comes back on after a
power outage occurred during operation. This setting is given priority in cases
where the indoor unit has an auto start ON / OFF jumper. Note also that
regardless of whether switch SW2-4 is on or off, the operating mode, set
temperature, fan direction and speed settings, and remote control prohibition
status are stored.
SW2-4 setting
OFF
(Factory setting)

permitted
Only OFF
Constant control is permitted prohibited
contact mode accepted
prohibited permitted

Instantaneous
contact mode

Constant
contact mode

prohibited
permitted
permitted
prohibited
prohibited permitted
Last command
prohibited
priority
permitted
permitted
prohibited
prohibited permitted
prohibited
Does not affect settings

Operating mode
temperaturet
Fan direction
and fan speed

Fan direction
and fan speed

Stop

Operating mode Fan direction


temperature and fan speed

Operations from
central controller,
contact input and
HA JEM-A input

6.Read Operating / Error Display Signal

KRP928B2S

Power supply for relay (DC 12V)


Operating control panel (Field supply)
MC

S5

M1

(+)
()
()

MR1
MR1
MR2

Abnormality display

MR2

7.Combining Equipment

Last command priority

D-BIPS

Wireless Remote Controller

Instantaneous contact input

Wired Remote Controller

Constant contact input

Wired Remote Controller

Total wire length max: 100m

Schedule timer

Forced stop contact input

Run / stop Input


Contact specs
No-voltage minute electric current contact
(Minimum applicable load DC 12V, 1mA or lower)

D-BIPS

ON / OFF control is rejected


(operate / stop / timer prohibition)
(NOTE 2).
During a forced stop, all
remote controller actions
are prohibited.

The central controller can be combined with the following devices.


Schedule timer

100 msec or more.


Contact - Open to close: air condition runs.
ON Close to open: air conditioner is stopped
(NOTE 1).
Contact - Open to close: air condition stops
Invalid (forced stop). Close to open: no change in
operating status.

Power source
for display

Operating Display

Relay specs (MR1 and MR2)


Coil voltage: DC 12V
Coil resistance: 160 10%
(Matsushita Electric HC
Relay, Omron MY Relay)
Wiring length
Max: 100m

Wireless Remote Controller

CB

Control mode

KRP928B2S

S1

The Operating / error signals can be read from the contact output (S5).
Output specs
M1: Turn MR 1 ON when the air conditioner is running.
M2: Turn MR 2 when a communication error has occurred between the KRP928B2S and
the air conditioner, or MR 1 is ON and the unit has stopped after an error.
MR 2 is not turned ON during a warning.

M2

What Happens

NOTE1: Since central equipment and HA JEM-A-compatible equipment both use


last command priority, the contact status and operating status of the air
conditioner might not match sometimes.
Example: If the unit is run from the central controller while the air
conditioner is stopped with an open contact, the contact will be
open and the unit will be running.
NOTE2: Operating mode and fan direction and speed settings can be changed.

CA

Operations from the remote controller

operating Change set


Start / stop Changemode
temperature Run / timer

The operating status of the air conditioner

ON

Forced stop contact input

Constant contact input

Central Remote Controller

Forced stop or remote


controller permission input

(Only during timer operation)

Ve-up controller settings

S8

OFF is reversed by an instantaneous input of

Constant contact input

Stops after recovering from a power outage

S1
SW3-1 SW3-2
operating mode setting setting

OFF

What Happens

(4) Contact input function settings (SW3-1 to SW3-2)


When using contact input (S1), choose one of the following functions.

Instantaneous contact
input (factory setting)

(Only during timer operation)

ON / OFF permitted permitted


prohibited
control is
Instantaneous rejected
prohibited permitted
contact mode
prohibited

Stops if the unit was stopped before the power outage


and runs if it was running.

ON

S1 pin
operating mode

Forced stop

NOTE also that a separate timer power source is needed when using the
schedule timer independently.
Power source specs: DC 16V, +10%, -15%, 200mA.
Recommended power source: Omron S82J-01015A. (Should be used with the
output voltage adjusted to the center, DC 16V.)

The remote controller permission / prohibition settings using the Ve-up controller are as
follows.
: permitted; : prohibited

1 4
1 2 3 4

0 7

Constant
contact mode
Forced stop

1 2 3 4

1 2 3 4

1 2

0 5
1 2 3 4

1 2 3

1 1

0 4

6
1 2 3

1 0

0 3

5
1 2 3

0 9

0 2

Timer operation
is accepted by
remote controller

1 2 3 4

0 1

Instantaneous Central priority


contact mode
Last command priority

Operations from
central controller,
contact input and
HA JEM-A input

HA JEM-A-compatible equipment

Overseas

0,1,3
10,11
2
1219
4
5
6,7

Stop

OFF
(Factory setting)

Automatic operation is not available from the central controller.


When using automatic operation using the wireless remote
controller, the central controller displays automatic cooling
(heating) and 25C. Even if the temperature is changed, it will
return to 25C after a while.

Run / timer

Japan

ON / OFF control
is rejected
Only OFF control
is accepted

What Happens

Stop

SW3-3 setting

Control mode

Control
code

ON / OFF controller

Destination

S1
operating
mode

Operations from the remote controller


Run control from the Stop control from the
central controller
central controller
Operating mode
temperature

Open the Kits case and set the switches on the circuit board.
(1) For Overseas / Japanese unit setting (SW3-3)
Room air conditioners, different methods are used for setting the temperature in
automatic mode, so this switch needs to be set.

Run / timer

NOTE

Optional Accessories

Central Remote Controller


ON / OFF controller

Instantaneous contact input


HA JEM-A-compatible equipment

3P157704-2A

Options

413

Optional Accessories

1.2.3

EDAU12-722

KDT25N32, KDT25N50, KDT25N63

Caution
This kit can be installed to the Ceiling mounted Built-in Type Air Conditioners. <Slim duct type>
When the Installation box for adapter PCB(KPP1B101) is used together, mount this kit before Installation box.
It is recommended to mount this kit before installing the indoor unit.

Combination table
The indoor unit model applied
Room Air Conditioners
VRV

Kit name
KDT25N50
CDK(X)D(S)25 35 50C(D)VM(A)(T)
FXD(Q)20 25 32 40 50M(N)VE(T)(5)

KDT25N32
CDK(X)D(S)25 35EAVM(A)(T)
FXD(Q)20 25 32PVE(T)(5)

KDT25N63
CDK(X)D(S)60C(D)VM(A)(T)
FXD(Q)63M(N)VE(T)(5)

Details of parts

Number of
pieces

Kit name
KDT25N32
KDT25N50
KDT25N63

5 Bottom plate insulation

B-1
(mm)

Slit

420

Shape

(mm) Score
A
700
900
1100

Kit name
KDT25N32
KDT25N50
KDT25N63

380

Number of
pieces

Designation

A
700
900
1100

Kit name
KDT25N32
KDT25N50
KDT25N63

390

4 Side plate insulation

S-2

240

(mm)

Chamber cover insulation


A

A
704
904
1104

C-1
(mm)

Slit

1
7 Hanger (right) insulation

S-1

Slit (mm)

3 Side plate insulation

200

Designation

T-2
Slit

207

380

Shape

(mm)

Slit

207

2 Top plate insulation

T-1

1 Top plate insulation

240

Designation

Kit name
KDT25N32
KDT25N50
KDT25N63

A
621
821
1021

H-1

8 Hanger (left) insulation

(mm)

H-2

9 Installation manual
(mm)

390

Slit
Number of
pieces

90

90

Shape
Slit

(This instruction)

When moving the unit at or after opening, hold the unit by the hanger brackets.
Do not apply force to the refrigernat piping, drain piping or flange parts.

How to attach

<Procedure> Stick the insulations carefully according to the following procedures


and do not make a gap between the adjacent thermal insulations.
(1) Stick the top plate insulation T-1 , T-2 to the indoor unit top plate.
(2) Cut off the side plate insulation S-1 following the score.(See the right figure)
(3) Stick the side plate insulation S-1 to the indoor unit right side plate.
(4) Stick the side plate insulation S-1 to the indoor unit left side plate
without cutting off the area surrounded by the score.
(5) Stick the side plate insulation S-2 to the indoor unit left side plate.
(6) Stick the bottom plate insulation B-1 to the indoor unit bottom plate.
(7) Stick the chamber cover insulation C-1 to the indoor unit chamber cover.
(8) Stick the hanger (left) insulation H-2 and the hanger (right) insulation H-1
respectively to the left and right hangers respectively.
(See the right figure for the sticking base line.)

Cut off the area shown with oblique lines and throw it away.
VRV model only
VRV and Room Airconditioners
KDT25N50, KDT25N63 model only

T-2
se

T-1

ing

lin

ba

ck
Sti

S-2
H-2

ARROW VIEW

S-1

Hanger brackets(right)

Hanger bracket (left)

H-2

H-1

Side plate(right)
Side plate(left)

C-1

S-1

H-1

DETAIL B

DETAIL C

B-1

3P131323-1C

414

Options

EDAU12-722

1.2.4

Optional Accessories

BRC1C61

5 12

5
3
7

hr

C
hr

6
8

NOT
AVAILABLE

TEST

L H

14

9
11
10
13
21
20

TEST

16

19

15

17

18

22
3PA59583-16Z-1

Options

415

Optional Accessories

EDAU12-722

ON/OFF BUTTON
Press the button and the system will start.
Press the button again and the system will
stop.
OPERATION LAMP (RED)
The lamp lights up during operation.
DISPLAY
(UNDER CENTRALIZED CONTROL)
When this display shows, the system is
UNDER
CENTRALIZED CONTROL.
DISPLAY

(VENTILATION/AIR CLEANING)
This display shows that the total heat
exchange and the air cleaning unit are in
operation (These are optional
accessories).

DISPLAY
(OPERATION MODE)
This display shows the current OPERATION
MODE. For cooling only type,
(Auto)
and (Heating) are not installed.

DISPLAY
TEST (INSPECTION/TEST
OPERATION)
When the INSPECTION/TEST OPERATION
BUTTON is pressed, the display shows the
system mode is in.
hr

DISPLAY

14
15

TIMER MODE START/STOP BUTTON


TIMER ON/OFF BUTTON

INSPECTION/TEST OPERATION BUTTON


16 This button is used only by qualified service
persons for maintenance purposes.
PROGRAMMING TIME BUTTON
17 Use this button for programming START and/
or STOP time.
TEMPERATURE SETTING BUTTON
18
Use this button for SETTING TEMPERATURE.
FILTER SIGN RESET BUTTON
19
FAN SPEED CONTROL BUTTON
20 Press this button to select the fan speed,
HIGH or LOW, of your choice.
OPERATION MODE SELECTOR BUTTON
21
Press this button to select OPERATION MODE.
AIR FLOW DIRECTION ADJUST BUTTON
22
NOTE
For the sake of explanation, all indications are
shown on the display in Figure 1 contrary to
actual running situations.

(PROGRAMMED TIME)

hr

This display shows the PROGRAMMED TIME


of the system start or stop.
8

DISPLAY
(SET TEMPERATURE)
This display shows the set temperature.

DISPLAY
(FAN SPEED)
This display shows the set fan speed.

DISPLAY

(AIR FLOW FLAP)

10
DISPLAY
11 TER)

12

DISPLAY

(TIME TO CLEAN AIR FIL-

(DEFROST)

NON-FUNCTIONING DISPLAY
If that particular function is not available, pressing the button may display the words NOT
AVAILABLE for a few seconds.
13 When running multiple units simultaneously
The NOT AVAILABLE message will only be
appear if none of the indoor units is equipped
with the function. If even one unit is equipped
with the function, the display will not appear.

416

3PA59583-16Z-2

Options

EDAU12-722

Optional Accessories

Installation

1.Remove the upper part of remote controller.


Insert minus screwdriver into the slots in the lower part of
remote controller (2 places), and remove the upper part of
remote controller.
The PC board is mounted in the
upper part of remote controller. Be
careful not to damage the board
with the minus screwdriver.

Upper Part of
Remote Controller

Lower Part of
Remote Controller

Minus screwdriver
Insert the minus
screwdriver and
twist lightly to remove.

2.Fasten the remote controller.


For exposed mounting, fasten with
the included wood screws (2).
For flush-mounting, fasten with
the included machine screws (2).

Wood Screws
(3.5 x 16)

Switch Box
(Field supplied parts)

Machine
Screws
(M4 x 16)

For the field supplied switch box, use optional accessories


KJB111A or KJB211A.
NOTE
Choose the flattest place possible for the mounting surface. Be careful not to distort the shape of the lower part of
remote controller by over-tightening the mounting screws.

Options

417

Optional Accessories

EDAU12-722

3.Wire the indoor unit.

NOTE
Connect the terminals on top of the upper part of
When wiring, run the wiring
remote controller (P1, P2), and the terminals of the
away the power supply wiring in
indoor unit (P1, P2). (P1 and P2 do not have polarity.) order to avoid receiving electric
noise (external noise).
Indoor Unit
Indoor Unit
P1, P2

P1, P2

Notch the part for the wiring to


pass through with nippers, etc.

Ground the shielded


part on the indoor
unit side. (NOTE.2)

Wiring Specifications
Sheathed vinyl code or cable
Wiring Type
(2 wire)
(NOTE.2)
0.75 1.25 mm2
Size

Lower part of
remote controller

PC Board

Upper Part of
Remote controller

(Wired from the rear)

PC Board

(Wired from the top)

NOTE) 1.Peel the shield and sheath for


the part that is to pass through
the inside of the remote controller case, as shown in the figure
below.

4.Reattach the upper part of remote controller.


Be careful not to pinch the wiring when attaching.

NOTE
1.The switch box and wiring for connection are not
included.
2.Do not directly touch the PC board with your hand.
If controlling one indoor unit with two remote
controllers

Peel the shield


and sheath.

2. Shield wire (2 wire) can be


used for remote controller
wiring, but it must confirm to
EMC (Electromagnetic Compatibility) (European Directive).
First, begin fitting from
the clips at the bottom.

Change the MAIN/SUB changeover switch setting as


described below.

PC Board

S
S
M
M
Main Remote Sub
Controller
Remote
(Factory Set) Controller

Set one remote controller tomain, and the other to sub.


NOTE
If controlling with one remote controller, be sure to set it
to main.
Set the remote controller before turning power supply on.

is displayed for about one minute when the power supply is turned on,

and the remote controller cannot be operated in some cases.

418

Options

EDAU12-722

Optional Accessories

If optional accessories are mounted on the indoor unit, the


indoor unit setting may have to be changed. Refer to the
instruction manual for each optional accessory.

FIELD SETTING
Procedure

When in the normal mode, press the


and the FIELD SET MODE is entered.

TEST

Select the desired MODE NO. with the

button for a minimum of four seconds,


button.

During group control, when setting by each indoor unit (mode No. 20, 21 and 23
have been selected), push the
button and select the INDOOR UNIT NO to
be set. (This operation is unnecessary when setting by group.)
Push the

upper button and select FIRST CODE NO.

Push the

lower button and select the SECOND CODE NO.

Push the

button once and the present settings are SET.

Push the

TEST

button for about one second to return to the NORMAL MODE.

(Example) If during group setting and the time to clean air filter is set to FILTER CONTAMINATION HEAVY, SET MODE NO. to 10, FIRST CODE NO. to 0, and SECOND CODE NO to 02.

UNIT NO.

MODE NO.

SECOND
CODE NO.

FIRST
CODE NO.

FIELD
SET
MODE

UNIT NO.

SETTING

.
1 7

TEST

Mode No. FIRST


Note) 1 CODE NO.

13(23)

Description of Setting

SECOND CODE No.


01

Note) 2

02

03

Ultra-long-life type
Filter Contamination - Heavy/Light
Approx. 5,000 hours
Approx. 10,000 hours
(Setting for spacing time of display time to clean air filter)
Long-life type Light Approx. 2,500 hours Heavy Approx. 1,250 hours
(Setting for when filter contamination is heavy, and
Approx. 200 hours
Approx. 100hours
spacing time to clean air filter is to be halved)
Standard type

Long-life filter type (Setting of filter sign indication time)


(Change setting when Ultra-long-life filter is installed)

Long-life filter

Ultra-long-life filter (1)

Spacing Time of Display Time to Clean Air Filter Count


(Setting for when the filter sign is not to be displayed)

Display

Do Not Display

Setting Number of Connected Skyair Simultaneous Operation System


Indoor Units(Setting for Simultaneous Operation System)

Pair

Twin

High Celling Setting


(Setting for when installed in a Ceiling higher than 2.7m)

Normal

High Ceiling 1

High Ceiling 2

Selection of Air Flow Direction (Setting for when a blocking pad kit has
been installed)

Air Flow Direction Adjust Function


(To be set when decoration panel for air outlet is installed)

Equippeed

No Equippeed

Air Flow Direction Range Setting

Upper

Normal

Lower

Normal

High Static Pressure

Low Static Pressure

Setting the External Static Pressure


(Setting according to the connected duct resistance)
(For FHYK, follow the High Ceiling Setting)

(Normal)

(High Ceiling)

10(20)

11(21)

Note:

1. Setting is carried out in the group mode, however, set the mode number inside the ( ) for individual
setting of the each indoor unit or confirmation after setting.
2. The SECOND CODE number is set to 01 when shipped from the factory.
However for the following cases it is set to 02.
zAir flow direction range setting.
3. Do not make any settings not given in the table above.
4. Not displayed if the indoor unit is not equipped with that function.
5. When returning to the normal mode, 88 may be displayed in the LCD in order for the remote
controller to initialize itself.
2P068938-1

Options

419

Optional Accessories

1.2.5

EDAU12-722

BRC7E531W7(C/O), BRC7E530W7(H/P)

1-1
1
ON OFF

1-2
H

M L

DOWN

10

ON OFF

UP

TEMP

FAN

11

hr.

M L TIME

UP

hr.

FAN

DOWN

13

RESERVE CANCEL

hr.

5
TEST

TIMER

12

MODE

15

hr.

7
SWING

14
16

TEST
TEST

17

3PA63363-21T-1

Receiver
FFQ-B

420

Options

EDAU12-722

Optional Accessories

DISPLAY
(SIGNAL
TRANSMISSION)
1
This lights up when a signal is being
transmitted.
DISPLAY

(OPERATION MODE)

M L

(SET TEMPERATURE)

10

11

12

AIR FLOW DIRECTION ADJUST


14 BUTTON

15

16

This display shows the set temperature.


hr.
DISPLAY hr.

(PROGRAMMED TIME)

This display shows PROGRAMMED


TIME of the system start or stop.
5

DISPLAY

TIMER RESERVE/CANCEL BUTTON

2 This display shows the current OPERATION MODE. For straight cooling
type,
(Auto) and (Heating)
are not installed.
DISPLAY

13

17

18

(AIR FLOW FLAP)

DISPLAY

(FAN SPEED)
The display shows the set fan speed.
TEST
DISPLAY
(INSPECTION/ TEST OPERATION)
When the INSPECTION/TEST OPERATION BUTTON is pressed, the display
shows the system mode is in.
ON/OFF BUTTON
Press the button and the system will
start. Press the button again and the
system will stop.
FAN SPEED CONTROL BUTTON
Press this button to select the fan
speed, HIGH or LOW, of your choice.
TEMPERATURE SETTING BUTTON
Use this button for SETTING TEMPERATURE (Operates with the front cover
of the remote controller closed.)
PROGRAMMING TIMER BUTTON
Use this button for programming
START and/or STOP time. (Operates
with the front cover of the remote controller opened.)
TIMER MODE START/STOP BUTTON

19

20

21

22

23

OPERATION MODE SELECTOR


BUTTON
Press this button to select OPERATION
MODE.
FILTER SIGN RESET BUTTON
Refer to the section of MAINTENANCE
in the operation manual attached to the
indoor unit.
INSPECTION/TEST OPERATION
BUTTON
This button is used only by qualified
service persons for maintenance
purposes.
EMERGENCY OPERATION SWITCH
This switch is readily used if the remote
controller does not work.
RECEIVER
This receives the signals from the
remote controller.
OPERATING INDICATOR LAMP
(Red)
This lamp stays lit while the air
conditioner runs. It flashes when the
unit is in trouble.
TIMER INDICATOR LAMP (Green)
This lamp stays lit while the timer is set .
AIR FILTER CLEANING TIME
INDICATOR LAMP (Red)
Lights up when it is time to clean the air
filter.
DEFROST LAMP (Orange)
Lights up when the defrosting operation has started. (For straight cooling
type this lamp does not turn on.)

3PA63363-21T-3

Options

421

Optional Accessories

1.2.6

EDAU12-722

DTA112B51 <Interface Adaptor for DIII-NET (SA)>


Accessories

Check if the following accessories are included in the kit.

1 Adaptor

Relay PCB

3 Relay harness

(for models
other than FFQ)

Note

PC board support

Clamp material

Installation manual

(for FFQ model)

Before opening control box lid, besure cut off the all air conditioner power of indoor unit and outdoor unit,
or you may get an electric shock..

SYSTEM OUTLINE
By connecting this kit to an optional controller for centralized control,
all units of the SKY AIR Series in the system can be controlled
as a group from the optional controller.

Adaptor 1

Set the triangle


marks together

X1A

One kit must be installed onto the master unit of each group.
X2A

ELECTRIC WIRING for FFQ model


X60A

(1) Mount the Adapter 1 on the indoor unit PCB by setting the triangle marks together.(Fig.1)
(2) Insert the Relay harness 3 into the connector of the Adapter 1 (Fig.2)
(3) Remove the remote control terminal block(X1M) from the control box mounted
inside the indoor unit.
(4) Connect the Relay harness 3 with the terminals F1 and F2 on the terminal block(X1M). (Fig.2)
(5) Mount the remote control terminal block(X1M) on the inside of the control box
as it was before removing it.
(6) Bind the extra wires with the attached Clamp material 5 so that
the wires do not go over the indoor unit PCB. (Fig.3)
(7) Connect the wires from the terminals F1 and F2 to the centralized control. (Fig.2)

Indoor unit PCB

X61A

Fig.1
Indoor unit Terminal block (X1M)

Indoor unit Terminal block (X1M)

Clamp material 5
(Clamp with earth wire)

Field wiring (Note.1)


P1 P2 F1 F2

Relay harness 3

Adaptor 1

Optional controller
for centralized control
P1 P2 F1 F2

Other group

Indoor unit PCB

Reverse side
X3A

X1A

X1A

Indoor unit PCB X61A


Adaptor X2A
X2A

adaptor 1

X2A

Fig.2

X3A

Indoor unit PCB X60A


Adaptor X1A

Noise filter

Clamp material 5
(Clamp noise filter to the side of control box)

Fig.3

Note 1. Wiring specifications ... Use a 0.75-1.25mm sheathed vinyl cord or cable (2 wires).
2. For details on compatible systems and how to connect to optional controllers,
see the instruction manual of the optional controller and technical reference materials.

C : 1P107904C

422

Options

EDAU12-722

1.2.7

Optional Accessories

KKP945A4

3P089958-1B

Options

423

Optional Accessories

1.2.8

EDAU12-722

KPW945A4

Before installation
Check the following parts

Name

Louver

Truss tapping screw

Installation manual

1piece

M4x4screws(max.7.5kW class)
M5x4screws(8.0/9.0kW class)

1piece

Shape

Quantity

Installation Procedure
Selection of Installation Location
Use when installing in a location that meets the following conditions.
O When installing near the border to a neighbor's house
O If exhaust blows directly on passers-by because outdoor unit is installed facing a road.
O If exhaust blows directly on vegetation

Space Needed for Installation


O

A minimum of 100mm is needed


between the back of the outdoor
unit and any obstructions
(walls, etc.)
re
mo

tha

n10

Installation of Louvers
Caution
Attach the louvers overlapping the standard grill.
Installing the louvers without the grill would allow hands to enter the fan area,
which is dangerous, so be sure to install the standard grill.
When pointing up

When pointing down

(1) Remove the 4 attachment screws from


the standard grill.

(1) Remove the 4 attachment screws from


the standard grill.

(2) Install the louver pointed up.

(2) Install the louver pointed down.

O
O

Overlap the standard grill and


screw both in together.
The attachment screws
are in the louvers.

(3) Installation complete

Overlap the standard grill and


screw both in together.
O The attachment screws
are in the louvers.
O

(3) Installation complete

3P089958-2C

424

Options

Specifications, designs and other content appearing in this brochure are current as of January 2007 but subject to change without notice.

EDAU 12-722
Printed in Japan 01/2007 B AK