You are on page 1of 24

1

Static Control
for industrial and cleanroom environments

2
www.meech.com
Meech International manufactures four interrelated product ranges:
Industrial static and dust control equipment
Electronics and cleanroom (ESD/ESA) control equipment
Surface cleaning systems
Compressed air energy saving and noise reduction products
This brochure covers the Industrial Static Control product range and is intended as an overview only. Further detailed
information on Meech product-based solutions and applications can be obtained by contacting any of our offices or
distributors or by visiting our web site at www.meech.com.
Contents:
Who is Meech? 3
Meech - a worldwide manufacturing company with offices in the UK, USA, Belgium, Hungary and China.
What is Static and What Problems Can it Cause? 4
A basic guide to static electricity, its origins and the problems it can cause.
Detection and Measurement 5
It is vital to understand the location and level of static charge present in a process.
The Four Technologies 6
Guide to the technologies used by Meech in its static control systems.
Product Selection Guide 7
Locate the products best suited to solve problems in your industry/application.
Testing and Measurement 8
Static detection and testing equipment for problem diagnosis.
Power Supplies 9-10
High voltage power supplies for AC and Pulsed DC systems.
Ionising Bars 11-12
Powerful AC and pulsed DC ionising bars to suit all applications.
Options for Ionising Bars 13
A range of added extras for use with Meech ionising bars.
EX Range 14
The Meech EX bars are fully approved and certified to ATEX / UL standards and control static safely in hazardous areas.
Ionising Blowers 15
Ionising blowers provide powerful, extended range ionisation
Ionising Air Guns and Nozzles 16-17
Compressed air ionisation for cleaning and product control.
Static Generation 18-20
Meech static generation systems provide temporary pinning of materials.
Cleanroom 200 Series 21-22
The Meech Series 200 range of ionisation equipment for the electronics and cleanroom industries.

Products shown in this document may be covered by one or more patents, patents applied for and/or registered designs
and/or trade marks. For further information please refer to our Head Office or visit www.meech.com.

3
Weve got the world covered
Wherever you are in the world, youll find Meech hard at
work, providing a wide range of businesses with specialist
expertise. From our headquarters and technical centre
in the UK, our manufacturing subsidiary in the USA and
sales offices in Belgium, Hungary, China and India, weve
got the world covered. In fact, our distribution network
now covers 50 countries, providing easy access to fully
trained, carefully selected Meech distributors, who can
provide in-depth support wherever you are based.
Outstanding quality as standard
Quality is at the heart of every Meech system. We
always work to the highest possible quality standards in
everything we do: manufacturing, customer support and
technical know-how. Our quality management system is
certified by BSI to ISO9001. Products manufactured by
Meech are also appropriately certified to international
standards which include CENELEC EN 60950, UL/CSA
(CUL) and CE. We also hold ATEX and ULEX approvals
for use in hazardous environments. So, you can be sure
youve chosen a solution and a company that will meet
your own exacting standards.
All the experience you need
Established in 1907, Meech has earned a worldwide
reputation for the design and manufacture of
effective, durable systems that are supported by our
knowledgeable technical team. With so much to offer,
no wonder our global user list has grown to in excess of
7,000 companies, including: Amcor, Avery Dennison, BP,
Brckner Group, Ford, GlaxoSmithKline, Honda, Nestl,
Nissan, Procter & Gamble, RPC Group and Tetrapak.
Worldwide Distribution Network

4
www.meech.com
Contact + Pressure + Separation
OR

Contact + Friction + Separation
What is Static?
Essentially, a static charge arises when an external force
causes electrons to be stripped from an atom leaving
it with an excess of protons and a net positive charge.
The electrons attach to a recipient atom, which will
consequently have an excess of electrons and will be
negatively charged.
What causes Static?
The most common causes are Friction, Pressure and
Separation. Examples range from the unwinding of
plastic films to the everyday occurrences of shocks from
cars and door knobs. Other causes include Induction,
whereby an insulator material can become charged if it
is brought into an electrical field. Temperature change
can also generate a static charge; a good example is the
generation of static charges on injection mouldings as
they cool.
Does this affect all materials?
Electrons can be stripped from practically all atoms
by one or more of the above processes. However if
it occurs where one of the materials is conductive,
that material will not hold the charge (assuming it is
grounded), whereas if the material is an insulator
(non-conductive) the charge will be unable to move
across the surface and literally becomes a static pool of
electrical charges.
What other factors are relevant?
The charge polarity is not normally an issue. But, it is
the magnitude of the charge that will cause problems
or not. Equally, many items each with a small charge
can act as an accumulator to produce a very high
static voltage (the battery effect); an example of
this is a container of small plastic parts that have just
been moulded. The force of any friction, pressure or
separation event will directly impact the magnitude of
the charge generated, so the higher the input energy,
the greater the charge. The type of material will
dramatically affect the polarity and charge produced.
Materials have different electron bond strengths, so
some materials will give up electrons relatively easily.
This phenomenon is described by the triboelectric
series. Lastly, the level of ambient humidity will play a
role in both the magnitude and life of a static charge.
Triboelectric
Series
For a more detailed explanation of the topics discussed here, please visit our website at http://www.meech.com/en/
downloads/brochures-booklets and download Static Electricity - Causes and Cures.

5
What are the problems?
There are at least 5 major areas where uncontrolled static
charges are of concern:
Product misbehaviour
Most commonly used packaging materials are
non-conductive. The friction and separation experienced
in the processing of such materials generates static
charges that can cause blockages in even the most
modern machine design. Loss of productivity and profit
can result.
Dust attraction
Neutral airborne particles are attracted to charged
surfaces and charged particles are attracted to neutral
surfaces. The resultant problems can lead to high reject
rates, high levels of rework, customer complaints and
loss of credibility.
Operator/Personnel shocks
The static voltage that leads to an unpleasant shock
when getting out of a car is of the order of 15kV. Yet
levels of 20-60kV are commonplace in the plastics and
converting industries. Not only are shocks from such
charges discomforting, the recoil effect can lead to more
serious accidents.
Fires and explosions
Where a process is carried out in a combustible
atmosphere, static charges can have sufficient energy to
cause ignition. This can occur where a grounded object
intensifies the static field to produce a spark, or where
a charge on an isolated conductor (e.g. a non-grounded
metal plate) reaches a threshold level and flashes over
to a proximity ground. Consequent fires or explosions
can result not only in the loss of production time but, in
extreme cases, the loss of complete factories!
Electrostatic discharge (ESD)
This is most common in the electronics industry, where
a side effect of the drive to smaller scales of circuit is an
increase in product sensitivity to static charges. 30 volts
is now the common threshold for semiconductors, and
hard disk reader heads can be susceptible to charges
of less than 3 volts. Problems can arise not only in
component assembly but also in later use of the finished
product.

6
www.meech.com
AC Static Elimination
A normal mains 110/240V, 50/60Hz AC supply is
increased by a special transformer to typically 7kV AC.
This high voltage is carried by a shielded HV cable to
the static eliminator, where it is connected to an array
of emitter pins that are stressed by the elevated voltage
in proximity to an earthed surface. This creates a high
energy "corona" or "ion cloud", in which a very large
number of positive and negative ions are generated. As
the AC cycle changes, either positive or negative ions
are produced in approximately equal quantities.
A statically charged surface of either polarity passing
close to this ion cloud will be quickly neutralised.

Pulsed DC Static Elimination
Whereas an AC system is limited to generating ions in
accordance with the frequency of the AC supply, Pulsed
DC technology allows control of not only frequency but
also ion balance (the relative proportion of positive and
negative ions). Mains voltage is transformed into high
voltage that is split into positive and negative outputs
and connected to dedicated emitters. Alternating
clouds of positive and negative ions are produced in
accordance with the chosen frequency setting (between
0.5 and 20Hz). The lower frequencies allow longer
distance ionisation to be achieved in still air whilst the
balance control allows the ion output to be adjusted
to suit the charge polarity on the target. Thus, Pulsed
DC systems can offer optimum solutions for specific
materials and more demanding applications.

Static Generation
Static Generation describes a method for creating a
controlled static charge on a non - conductive material
that will allow a sound, but temporary, adhesion between
surfaces with charges of opposite polarity. A high DC
voltage (up to 50kV) is safely produced and is carried
through a HV cable to a static generator bar, where it is
connected to an array of suitably designed emitter pins to
generate a "corona". The DC voltage may be positive or
negative, depending on the application and the
characteristics of the materials to be bonded. The emitter
pins are positioned within close proximity of a grounded
surface (fig.1) or, for greater effect, a generator bar with
emitter pins of the opposite polarity (fig.2). The material(s)
to be bonded are passed into the "corona", resulting in
bonding to the grounded surface or to the other material.



Pulsed DC Ionising Bar
Ionisation at
electrode points
Surface with no
residual charge
Surface with high
positive charge
Direction of material
Negative Ions attracted
to positive charge over
long distance
Positive Ions
not attracted
to surface charge.
Dedicated positive and
negative emitter pins
Bar casing
connected
to earth
HT AC supply to
electrode pin
AC Ionising Bar
Ionisation at
Electrode Point
Surface with no
residual charge
Surface with high
positive charge
Direction of material

7
PRODUCT TYPE
INDUSTRY/APPLICATION
AC
Bars
AC
Blowers
AC
Nozzles
AC
Guns
AC
Curtains
Pulsed DC
Static
Generation
Series 200
AUTOMOTIVE
Interior Component Painting/Spray
Plastic Components Painting/Spray
Vehicle Body Painting/Spray
CONVERTING
Coating
Laminating
Plastic Bag (various types)
Sheeting
Slitting
Wind/Rewind
ELECTRONICS
Assembly/PC Boards
Bench-top
Cleanroom
PACKAGING
Blister Packing
Canning/Bottling
Form Fill Seal
Stretch Wrapping
Wrapping Machines
PAPER & BOARD
Corrugated Board
Paper Production
PLASTICS - FLEXIBLE
Blown Film
Cast Film
PLASTICS - RIGID
Blow Moulding
Extrusion
GRP
Injection Moulding
In-Mould Labelling
Rotational Moulding
Thermo/Vacuum Forming
PRINTING
Binding/Finishing
Flexo/Litho Sheet
Inkjet
Laser
On-demand/Digital/Thermal
Screen
Tampo
Web Printing
TEXTILES
Beaming/Warping
Carding
Folding
Inspection
Stenters

8
www.meech.com
Testing and Measurement
983v2 Static Locator
The Model 983v2 Static Locator provides accurate measurement
of static electrical charges. Its design enables fast response,
low drift and ease of operation. The wide measurement range of
-200kV to +200kV handles all applications.
984v2 Ion Sensor
The Meech Model 984v2 Ion Sensor is an easy-to-use device
for checking the performance of both AC and DC powered static
eliminator bars. Indicator lights confrm the presence of ions and,
in the case of a DC power source, their polarity.
Test Kit - 983v2 & 984v2
The Meech 983v2 & 984v2 test kit gives operators &
maintenance staff the ability to diagnose static related issues
and monitor the performance of their ionising equipment.
990 Surface Resistance Meter
The 990 SRM measures both surface resistivity and resistance
to ground, giving simple repeatable measurements of
conductive, static dissipative and insulative surfaces.
Customers opinion:
We are thrilled with the set up now in place and the money it has saved enables us to deliver the performance solutions
we promise our clients on budget, as well as guaranteeing the high quality aesthetics associated with our product.
~ Process Engineer, Viracon, USA


9
904
Model 904 is the constant voltage power supplies, designed
to provide a 7kV source for Meech AC ionizing equipment. It is
adjustable to operate at 100-120V or 200-240V input voltage and
is available in either 50Hz or 60Hz versions.


905
Model 905 is the constant voltage power supplies, designed
to provide a 5kV source for Meech AC ionizing equipment. It is
adjustable to operate at 100-120V or 200-240V input voltage and
is available in either 50Hz or 60Hz versions.
904CM
The 904CM system monitors the performance of AC ionising
bars to allow maintenance to be carried once the performance
has dropped below a chosen level. Additional spark detection
circuitry allows early detection of potential problems or for
damaged equipment to be identifed and replaced.
The system comprises three parts, a modifed 904 power unit,
the 904CM monitoring unit and insulating brackets for AC bars.

AC Power Supplies
Due to the fact static cant be seen by the naked eye, it is often not considered as a cause of production problems.
However, with our operator experience and Meechs expertise in static control solutions, we quickly identifed where
improvements could be made. The Meech systems now enable us to run our rewinding machines at twice the previous
speed and have eliminated potential quality problems. Time is also saved with the Feedback automatic control system
and operators are no longer concerned about the possibility of shocks due to static built up. Everyone from the
management to the machine operators are delighted with the results.
~ Production Manager, Technibond, UK


10
www.meech.com
Customers opinion:
We were very impressed with the level of technical information that we received from Meech to ensure
optimum operation of the equipment.
~ Design Engineer, Autobond, UK
977v3
The Model 977v3 Pulsed DC Controller has been designed to
operate with the full industrial range of Meech Pulsed DC static
elimination equipment. It is light and compact but able to cope with
the most technically demanding industrial applications. In addition to
the ability to control power output, frequency and polarity, the 977v3
also offers alarm and remote monitoring and control functionality.





977CM
The 977CM Current Monitoring Pulsed DC Controller, brings
together powerful long-range ionisation; closed-loop feedback;
self-monitoring and remote reporting. A complete package, unique
to Meech. Self-monitoring and adjustment of performance allows
optimum control of static for much longer periods than previously
possible. Local display and output signals alert operators to the need
to clean the equipment.
977HL
The 977HL Current Monitoring Pulsed DC Controller, brings
together powerful long-range ionisation; closed-loop feedback;
self-monitoring and remote reporting. A complete package, unique
to Meech. Self-monitoring and adjustment of performance allows
optimum control of static for much longer periods than previously
possible. Local display and output signals alert operators to the need
to clean the equipment.
DC Power Supplies

11
AC Ionising Bars
910 Bar
The Model 910 bar incorporates an inductively coupled design
that achieves powerful static neutralisation with completely
shockproof operation. The design is compact, yet rugged,
enough for most industrial applications .
912 Circular Bar
The Model 912 range of circular static eliminators is based on the
popular Model 910 shockless bar. The inductively coupled
design provides powerful static neutralisation and completely
shockproof operation.
914 Bar
The model 914 AC Ionising Bar shares the same resistive
coupling of the 915, whilst similar to the 910 in size. It provides
an ideal replacement for old style bars and its compact design
allows installation on cramped machinery.
915 Bar
The Meech Model 915 AC Bar meets the most demanding
of static elimination problems. The powerful performance of
the Model 915 provides very fast decay times and effective
ionisation up to distances of 150mm. The design of the 915 is
such that it can operate for long periods between cleaning.

913 Flow Tube
The Meech Model 913 Flow Tube neutralises static charges
on materials in handling and conveying systems. The Model
913 Flow Tube incorporates in-line ionisation, which eliminates
material clinging and clogging in ducting systems due to static
charges. The 913 Flow Tube is available in a range of diameters
to suit the specifc application.
The 915 systems worked straight away and have needed no maintenance since installation. We will defnitely
call on Meech if we have any further static problems.
~ Maintenance Manager, 4DM, UK

12
www.meech.com
Hyperion 929IPS Bar
The Hyperion 929IPS is a compact pulsed DC ionising
bar with Integrated Power Supply (IPS). Powered by
24VDC, the 929IPS delivers powerful ionisation for close
to midrange applications.
The need for powerful ionisation to cope with modern fast
machinery is answered by the Hyperion 929IPS. Compact
dimensions of just 26 x 43mm makes it easy to install on
printing and converting machinery.


Hyperion 971 Bar
The Hyperion 971 Pulsed DC bar delivers powerful, long
range ionisation to control static electricity on a wide range
of applications, yet shockless and safe for operators to
handle. For the most demanding ones, the integrated air-
boost can be used to increase its capability at distance.
The design has been optimised to deliver extra-long
service life and to reduce the effects of contamination and
to allow easy maintenance.
Hyperion 971IPS Bar
The Hyperion 971IPS is a long range pulsed dc ionising
bar with an Integrated Power Supply (IPS). Powered by
24V, the 971IPS offers all the features of the 971 bar with
the additional beneft of low voltage wiring. Ion Current
Monitoring provides local and remote cleaning alerts
to ensure maximum performance. Using a BarMaster
programmer, the output can be optimised to suit a
particular application.
DC Ionising Bars
Customers opinion:
It was, something of a revelation - a neat and simple solution that overcame a very big problem.

~ Finishing Manager, London, UK

13
Quick Connect for 915 AC Static
Bars
On machinery where AC bars
need to be disconnected
periodically, the quick-connect
Replacement Pins for Hyperion 971
Bar
Replacement pins allow model
971 pulsed DC bars to be kept
in as-new condition
Water Resistant
A water resistant option allows
the installation of bars where
routine machine cleaning can
cause them to be splashed.
Splitters
The splitters have been
developed to enable a number
of ionising products to be
powered from the Meech
Pulsed DC Controllers
Dust Proof for 915 AC Static Bars

For installation in dirty or dusty
environments the dust proof
option improves reliance of the
bar.
Inter Connect for Hyperion 971
Pulsed DC Bars
Installation of pulsed DC bars
on wide machinery can be
made easier by installing a
series of interconnected bars.
Air Assist
The effective range of bars can
be increased by the addition of
an air-boost system.
Feedback System
The 988 Sensor Bar works in
conjunction with the 977CM
Pulsed DC Controller; enabling
the system to provide
closed-loop static control.
900vs2
Monitoring of AC systems
provides piece of mind. Clear
LEDs indicate the state of the
HT output.
Hyperion BarMaster
Hyperion Barmaster is a
unique device that temporarily
connected inline with the 24V
power supply to the bar allows
adjustment of the output and of the clean-pin alert
settings.
Options for AC and DC Ionising Bars
We are very pleased with the results obtained. We managed to solve the problem existing in our production
plant quickly; the Feedback System manufactured by Meech guarantees the smooth running of the whole
production process, and the products leaving our factory are of the worlds highest quality

~ Process Engineer, 3M, Poland

14
www.meech.com
Ex Range
915Ex Bar
The Meech Model 915Ex is based on the popular 915 AC
system. It is classifed for use in hazardous environments and is
particularly suited to coating, laminating, fnishing and gravure
printing applications. The 915Ex is certifed by Baseefa to comply
with Article 9 of the Council Directive 94/9/EC (ATEX). 915Ex
bars are also UL approved to Class I, Div 2, Group D hazardous
locations.
935Ex Blower
Utilising high-power 915Ex bars and a remote fan unit, the 935Ex
provides excellent long-range ionisation. Uses include solvent-
based coating heads.
957 Curtain with 915Ex Bar
Model 957Ex consists of a Meech 915Ex static eliminator
bar mounted on to Energy Saving Compressed Air Curtain.
It produces a high speed, laminar beam of ionised air for long
range static neutralisation and dust removal. It is available in
a variety of lengths. The 915Ex Bar is BASEEFA (EXs IIA T6 -
Zone 1 on 2) and UL approved for use in hazardous areas.
976Ex Bar
The Meech Model 976Ex is unique and has been designed to
extend the exceptional performance and other benefts of the
976 Pulsed DC system to classifed hazardous environments. It
is particularly suited to coating, laminating, fnishing and gravure
printing applications. The 976Ex is certifed by Baseefa to comply
with Article 9 of the Council Directive 94/9/EC (ATEX). It is also
UL approved to Class I, Div 2, Group D hazardous locations.
Customers opinion:
ISP Calvert City changed to the Meech 915Ex bar approximately 5 years ago. Since the installation, we have
seen a signifcant decrease in equipment downtime related to static elimination devices. We are pleased with
the performance of the bars.
~Senior Reliability Engineer, ISP Chemicals, LLC, USA

15
Ionising Blowers
935 Blower
The Model 935 Ionising Blower provides effective long range
ionisation over a large area. Its versatility makes it suitable for a
wide range of industrial applications. The Model 935 comprises
an ionisation head and an integrated fan system. A high volume
fow of ionised air is generated by blowing air through the
ionisation head at the mouth of the unit.
957 Ionised Air Curtain
The Meech Model 957 Ionising Air Curtain is an extremely
versatile unit that provides effective static neutralisation and
dust removal in a wide range of industrial applications. The unit
comprises a Model 915 bar mounted on to an Energy Saving
Compressed Air Curtain, to produce a high speed, laminar beam
of ionised air.
958 Sheet Separator
The Meech Model 958 Sheet Separator system has been
designed to allow effcient operation of automatic sheet feeders
by eliminating static charges and separating the sheets with a
controlled blade of ionised air. The system comprises of one or
more full fow Meech ionising air curtains on adjustable brackets,
which are mounted on the cross rod of the feeder.
We have been delighted with all the static solutions that Meech has provided. They have resulted in higher
yields and throughput on our contact lens production lines.
~ Production Engineer, Cooper Vision, UK

16
www.meech.com
Ionising Air Guns and Nozzles
954 Gun
The Meech Model 954 is a hand-held ionising air gun used for
neutralising static charge and removing dust contamination in a
wide range of industrial processes. The ergonomic, lightweight
design of the 954 provides simple, quiet and effective operation.
955 Gun
The Meech Model 955 is a hand held ionising blow gun. It is a
portable and effcient way of removing static charges and dust
in a range of industrial applications. An electrical centrifugal
fan provides high velocity air fow, avoiding the need for a
costly compressed air supply. The 955 requires just a standard
single phase 110V or 240V supply, thereby making the unit fully
portable.
940 Nozzle
The Model 940 is available as either a Through Type or Blank
Endnozzle. The Through Type nozzle allows the HT cable to
pass through so that more than one nozzle can be installed in
series on to the cable. It is suitable for applications requiring the
removal of electrostatically attracted dust and for longer range
static neutralization
942 Nozzle
The Meech Model 942 is a small, lightweight in-line ionising
air nozzle with highly effcient air fow characteristics. It can be
used either as a single unit (Blank End) or with two or more units
connected in series (Through Type).The 942 is designed for use
with low pressure air lines. It is particularly suited to applications
on sheet feeder and delivery systems.
Customers opinion:
We were impressed with the prompt service and excellent solution offered by Meech. Although it was
originally installed as a temporary measure, it is now always switched on to ensure uninterrupted production
in our factory.
~ Production Director, Moffat Press, UK

17
261 Nozzle
Meechs Model 261 Ion Nozzle is a small, lightweight ioniser
for use with our range of Pulsed DC Controllers. It is suitable
for installation into machinery and equipment used within
cleanrooms as well as industrial environments. It is quick to
install, using the optional mounting bracket, and easy and safe to
use.
261 Slotted Ionising Nozzle
The Slotted 261 Ion Nozzle produces a blade of ionised air.
Particularly useful for separating sheets on printer feed-stack.
Mounted on adjustable brackets the ionised air breaks the bond
between the sheets and prevents double-feeding.
261 Flexi Ionising Nozzle
The Meech Model 261 Flexi Nozzle is a small, lightweight 261
nozzle with the discharge outlet extended by fexible knuckle
trunking. It is particularly suited to high speed applications such
as sheet delivery systems. The addition of fexible knuckle
trunking enables the system to deliver ionized air with accuracy
into diffcult to reach places, where conventional systems would
be ineffective or impossible to install
Ionising Air Guns and Nozzles
Printing on metallised paper can be problematic due to static. However since the installation of the Meech 261
Flexi nozzles on two presses, our press teams have reported a signifcant improvement in run performance
on our metallised stocks. Meech service post installation during the frst few weeks of production has been
excellent.
~ Production Director, Darley Ltd, UK
Options
261 Brackets
Universal mounting brackets
simplify installation of 261
nozzles.


18
www.meech.com
Static Generation
992v3 (30kV and 50kV)
The Meech Model 992v3 (30kV and 50kV) Static Generators
create a controlled level of static charge to impart temporary
bonding between materials, at least one of which is insulative.
The 992v3s provide a high voltage output adjustable over the
range 0-50kV or a constant current that can be adjusted between
0 and 260A (50kV) or 0 to 500A (30kV) .The selected output
voltage or current is shown on a digital display. The adjustability
of the output voltage and current enables the unit to be used in
a multitude of applications and with a variety of materials. The
992v3 generators are used in conjunction with the Model 993R
sparkfree generator bar or selection of pinning heads and are
available in either negative or positive output polarity versions.


993R Generator Bar
The Meech Model 993R is a high performance Generator Bar
for use with the Meech range of 30kV and 50kV high voltage
DC static generators. Resistively coupled emitter pins deliver
smooth, controlled pinning whilst spark free operation avoids
tripping out on intermittent applications.
995v3 Flexible Pinning Head
The Model 995v3 Flexible Pinning Head is designed for use with
the Meech range of high voltage static generators. Resistively
coupled emitter pins deliver smooth, controlled pinning
whilst spark-free operation avoids tripping out on intermittent
applications. The fexible trunking permits accurate positioning to
enable targeted pinning of non-conductive materials.

Customers opinion:
This new solution is a signifcant improvement on the previous vacuum system that could result in marked
products. The Meech engineer understood our requirements and has given us excellent service and support.
a Model 992v3 static generator and a 994SPP Single Point Pinning System.
~ Manager, Edart Electronics, China

19
995 Pinning Head
With a Compact design in a PTFE body, the 995 series of pinning
heads deliver exceptional pinning of multi-layer plastics. Uses
include bag making and fow-wrapping machinery.
995 Edge Pinning Claw
The 995 Edge Pinning Claw is a powerful pinning head intended
for use on cast-flm lines. Pinning the edges of the cast flm to
the chill roller prevents necking of the flm. Resistively coupled
titanium pins deliver spark free pinning. The 995-CLAW can be
powered from either our 30kV or 50kV range of 992v3 generators
995 Dirty Environment Pinner
The 995 Dirty Environment Pinner provides electrostatic pinning
in applications where the risk of contamination is high.
The resistively-coupled titanium pins are shrouded to offer a
physical protection whilst an open design avoids the build up
of contaminant. This makes them ideal for food overwrapping
machinery where spillages are common.
995 Hand Held Pinner
Manual pinning applications require safe, spark-free operation.
The integral switch on the 995 Hand-held pinner allows the
operator to switch the system on only when required.
Static Generation
Continuing diffculty with our existing static pinning system was causing very low productivity. So, we
contacted Meech for and alternate viewpoint. The Meech engineers advised on the use and installation of a
Hydra pinning system. We have now achieved consistent performance on our in mould labelling process and
much higher productivity.
~ Managing Director, Shalam UK Ltd, UK

20
www.meech.com
994 IML Generator
The 994-IML Static Generator has been designed after
consultation with In Mould Labelling OEMs. The criteria
they laid down was that the unit needed to be compact,
light & reasonably priced. The Meech 994-IML provides
0-20kV, Negative polarity, in a lightweight package with
connections to suit the Meech Hydra IML pinning system.

994 Single Point Pinner (SPP)
The 994-SPP system provides individually resistively
coupled pinning heads. Splitter blocks with four or six
outlets give spark-free pinning; ideal for larger in-mould
labelling applications.


994 Hydra (IML)
The Hydra system offers miniaturised pinning heads
that can be installed in the smallest of in-mould labelling
applications; including drinking cups and food containers.
Modular design makes it suitable for both end-users and
OEMs.

Static Generation - IML
Options
Hydra splitters
Installation of pulsed DC bars
on wide machinery can be
made easier by installing a
series of interconnected bars.
Hydra HT Ultra Flexible Cable
The effective range of bars
can be increased by the
addition of an air-boost
system.
Customers opinion:
People have to accept that they may need to equip either the press or the fnishing equipment with a static
elimination system if it is needed, the solution is quite straightforward and it is usually inexpensive, particularly
when you take into account the usual improvements to productivity.
~ Managing Director, IBIS Integrated Bindery Systems, UK

21
Cleanroom 200 Series
221 and 225 Blower
The Model 225 Ionising Blower provides a high level of ESD
protection with excellent workstation coverage, quiet operation
and ease of maintenance. Standard lengths of 600mm and
1200mm are available to suit the specifc application. The 225
is the top-of-the-range Model and is provided with an extensive
range of features and options.
212v2 Blower
The Model 212v2 Bench top Ioniser is a compact unit which
complements the Meech Series 200 product range. This model
provides excellent work station coverage and a high level of
ESD protection. It has been specifcally designed to meet the
demanding performance requirements in applications such as:
Semiconductor manufacture
Electronics assembly & testing
Test and re-work
Optics, contact lenses & fibre optics
Medical device manufacture & packaging
Wave soldering

233v3 Pulsed DC Controller
The Model 233v3 Pulsed DC Controller has been designed
to operate with the Series 200 range of ionisers for ESD
applications. The 233v3 is light, compact and features lockable
plug and socket connectors for quick release. It also provides the
option of Steady State DC (SSDC) output.
251 Ionising Gun
Meechs Model 251 Ion Gun is a robust, lightweight injection
moulded product for use with the Model 233 Pulsed DC
Controller. It is suitable for contamination blow-off and
neutralisation of static charges in electronic applications and
cleanroom environments. It is quick, easy and safe to use.
Supplied with 2 metres of cable as standard.
By installing the Meech 241 static control ioniser system on our machines, we can ensure maximum
effectiveness and our customers can achieve better repair yields throughout their polarisation replacement
process. We have also been able to increase our customer base by introducing smaller companies to the
LCD repair business.

~ Company Director, Clarion Design, UK

22
www.meech.com
261 Ionising Nozzle
Meechs Model 261 Ion Nozzle is a small, lightweight ioniser,
designed for use with the Model 233 Pulsed DC Controller. It is
suitable for installation into machinery and equipment used within
electronic and cleanroom environments. It is quick to install,
using the optional mounting bracket, and easy and safe to use.
261 Flexi Ionising Nozzle
The Meech Model 261 Flexi Nozzle is a small, lightweight ioniser
with the discharge outlet extended by fexible knuckle trunking.
The 261 Flexi Nozzle is designed for use with Meech Pulsed
DC Controllers and is suitable for installation into machinery
and equipment in both industrial and electronics environments.
It is particularly suited to high speed applications such as sheet
delivery systems. The addition of fexible knuckle trunking
enables the system to deliver ionized air with accuracy into
diffcult to reach places, where conventional systems would be
ineffective or impossible to install
271, 272, 273 Flexible Ion Nozzle
The Model 271 Flexible Ion Nozzle is a compact, hands free
ioniser, designed for repetitive cleaning tasks. It is powered by
the Model 233 Pulsed DC Controller. It is suitable for electronic
and cleanroom environments and is quick to install and easy and
safe to use.
The 272 includes a pneumatic foot pedal that allows the operator
to regulate both the fow of air and activate the ionization feld
hands free.
The 273 includes a standard foot switch which allows the
operator to regulate the air fow to the fexible nozzle.
Cleanroom 200 Series
Customers opinion:
Contamination will always be a concern, however, being able to call on the expertise at Meech International,
means we are confdent that any issues can be overcome. We have been impressed with their knowledge of
static and how it affects our industry and see them as partners when integrating static control solutions.
~ Production Manager Cleanrooms, Sovrin, UK


23
Meech is also a leading provider of:
Web Cleaning Systems Typically used within the
printing and packaging industries to remove
contamination, improve print quality and increase
productivity.
JetStream Air Knife Systems Energy efficient air
knife systems that are used for contamination and
surface moisture removal.
Air Technology Equipment Compressed air
products that save energy, reduce noise levels and
provide efficient cooling.
All you need, from the
best in the business


Meech Static Eliminators Ltd 2013 www.meech.com
Meech International
2 Network Point
Range Road, Witney
OX29 0YN, UK
Tel: +44 (0)1993 706700
Fax: +44 (0)1993 776977
email: sales@meech.com
Meech CE
2151 Ft
Szchenyi t. 46
Hungary
Tel: +36 27535075
Fax: +36 27535076
email: ce@meech.com
Meech Static Eliminators USA Inc
2915 Newpark Drive
Norton, OH 44203
USA
Tel: +1 330 564 2000 / 1 800 232 4210
Fax: +1 330 564 2005
email: info@meech.com
Meech Static Eliminators (Shanghai) Co. Ltd
7G, 7F, LP Tower
#25 Xiangfeng Road
201103 Shanghai
China
Tel: +86 400 820 0102
Fax: +86 21 6405 7736
email: china@meech.com
Meech Elektrostatik SA
Kaiserbaracke 66
B-4780 St.Vith
Belgium
Tel: +32 8086 2983
Fax: +32 8086 2821
email: mesa@meech.com
Meech Shavotech
Shavo House, Survey No.21A / 10 B, Plot No.394
South Main Road, Koregaon Park, PUNE 411 001
India
Tel: 020-26069641/ 26069642,
Fax: No.020-26069644
e-mail: india@meech.com