You are on page 1of 3

Siemens AG 2013 - 2014.

All rights reserved


A5E31876033-AE, 08/2014 1

SIMATIC
S7-1500/ET 200MP
Amendments to documentation S7-1500/ET 200MP
Product Information

Introduction
Scope of validity of the product information
This product information supplements the documentation for S7-1500/ET 200MP and takes precedence over our system
manuals, function manuals and manuals.
Security information
For the secure operation of Siemens products and solutions, it is necessary to take suitable preventive action (e.g. cell
protection concept) and integrate each component into a holistic, state-of-the-art industrial security concept. Third-party
products that may be in use should also be considered. You can find more information about industrial security on the
Internet (http://www.siemens.com/industrialsecurity).
Supplement to documentation S7-1500/ET 200MP
S7-1500/ET 200MP - Marine approval
Certificates for marine approval are available for SIMATIC S7-1500/ET 200MP. The certificates can be found on the Internet
(http://support.automation.siemens.com/WW/view/en/56926743/134200).
S7-1500/ET 200MP - Calibration of analog modules
The "Calibration" function (calibration in RUN) is only possible with the following configurations.
Module/module name Configuration Article no.:
AI 8xU/I/RTD/TC ST QI 1 x 8-channel with value status 6ES7531-7KF00-0AB0
AI 8xU/I/RTD/TC ST 1 x 8-channel without value status
AI 8xU/I HS QI 1 x 8-channel with value status 6ES7531-7NF10-0AB0
AI 8xU/I HS 1 x 8-channel without value status
AQ 8xU/I HS QI 1 x 8-channel with value status 6ES7532-5HF00-0AB0
AQ 8xU/I HS 1 x 8-channel without value status
AQ 4xU/I ST QI 1 x 4-channel with value status 6ES7532-5HD00-0AB0
AQ 4xU/I ST 1 x 4-channel without value status
AI 4xU/I/RTD/TC/ AQ 2xU/I ST QI 1 x 6-channel with value status 6ES7534-7QE00-0AB0
AI 4xU/I/RTD/TC/ AQ 2xU/I ST 1 x 6-channel without value status
AI 4xU/I/RTD/TC ST QI 1 x 4-channel with value status 6ES7531-7QD00-0AB0
AI 4xU/I/RTD/TC ST 1 x 4-channel without value status
AQ 2xU/I ST QI 1 x 2-channel with value status 6ES7532-5NB00-0AB0
AQ 2xU/I ST 1 x 2-channel without value status

Amendments to documentation S7-1500/ET 200MP
2 A5E31876033-AE, 08/2014
S7-1500/ET 200MP - Configuring
You can configure the following modules with STEP 7 (TIA Portal) as of V13.0.0 with HSP0102 or with a GSD file.
Module Article number
AI 4xU/I/RTD/TC/ AQ 2xU/I ST 6ES7534-7QE00-0AB0
AI 4xU/I/RTD/TC ST 6ES7531-7QD00-0AB0
AQ 2xU/I ST 6ES7532-5NB00-0AB0
S7-1500/ET 200MP - MSI/MSO
The function "Module-internal Shared Input / Shared Output" (MSI/MSO)" can be configured with the GSD file. Configuration
with STEP 7 (TIA Portal) is possible starting from V13, Update 3.
S7-1500/ET 200MP with PtP modules - Parameter assignment of data flow control
Communication may come to a standstill when you use communication modules with RS232 interface, if the following
hardware data flow control was configured:
Hardware RTS always ON
Hardware RTS always ON, ignore DTR/DSR
The behavior occurs for the following communication modules with firmware version V1.0.0:
CM PtP RS232 BA (6ES7540-1AD00-0AA0)
CM PtP RS232 HF (6ES7541-1AD00-0AB0)
The behavior of the modules has been remedied as of firmware version V1.0.1.
S7-1500/ET 200MP - Use of PTC resistors
PTC resistors are suitable for temperature monitoring of electrical devices, such as motors, drives, and transformers. Use
Type A PTC resistors (PTC thermistor) in accordance with DIN/VDE 0660, part 302. In doing so, follow these steps:
1. Choose "Resistor (2-wire terminal)" and "PTC" in STEP 7.
2. Connect the PTC using 2-wire connection technology.
If you enable the "Underflow" diagnostics in STEP 7, it will be signaled for resistance values <18 . In this case, this
diagnostic signifies "Short-circuit in the wiring".
The following figure shows the address space assignment for analog modules with PTC resistors.

Figure 1 Assignment of the address space for analog modules with PTC resistors

Amendments to documentation S7-1500/ET 200MP
A5E31876033-AE, 08/2014 3
ET 200MP with IM 155-5 PN ST
Channel diagnostics
In contrast to the order specified in the manual, the User Structure Identifiers (USI) are structured as follows:
USI data block
Reserved bytes
Manufacturer-specific diagnostics
MSI/MSO
As of firmware version V2.0.0, the IM 155-5 PN ST interface module supports the module-internal Shared Input/Shared
Output (MSI/MSO) function with up to two IO controllers.
ET 200MP with IM 155-5 DP ST
Operation on Y-link
As of firmware version V2.0.0, the IM 155-5 DP ST interface module can be operated as DP slave after the Y-link.
Technical specifications
For the IM 155-5 DP ST, the address space of each module can be assigned a maximum of 64 bytes of inputs and a
maximum of 64 bytes of outputs.
ET 200MP with IM155-5 PN HF - Shared Device
In contrast to the information in the ET 200MP IM155-5 PN HF manual, you cannot use the shared device function with more
than 2 IO controllers.
ET 200MP - Response times
Additional information about performance measurements is available on the Internet
(http://support.automation.siemens.com/WW/view/en/34677186/136000&cspltfrm=0&cssw=0&csbinh=5).
S7-1500 CPU 1517-3 PN/DP

Note
Use of the 2nd PROFINET interface (X2) for communication with a configuration system