Inverter Series
R410A
N
E
W
!
SPLIT-TYPE AIR CONDITIONERS
L-179-13-MD034-A SI-1308 Printed in Japan(MDOC)
New publication effective August. 2013
Specifications subject to change without notice.
HEAD OFFICE: TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
http://Global.MitsubishiElectric.com
Inverter Series
R410A
N
E
W
!
SPLIT-TYPE AIR CONDITIONERS
Outdoor unit
Inverter Series
01-02
4hp 3hp 2.5hp 2hp
PRODUCT LINE
-
UP
Remote controller
Ceiling-cassette
Ceiling-suspended
Ceiling-concealed
PLY
PCY
PEY
INVERTER TECHNOLOGIES
Mitsubishi Electric inverters ensure superior performance including the optimum control of operation
frequency. As a result, optimum power is applied in all heating/cooling ranges and maximum comfort is
achieved while consuming minimal energy. Fast, comfortable operation and amazingly low running cost
Thats the Mitsubishi Electric promise.
Inverters electronically control the electrical voltage,
current and frequency of electrical devices such as
the compressor motor in an air conditioner. They
receive information from sensors monitoring operat-
ing conditions, and adjust the revolution speed of
the compressor, which directly regulates air condi-
tioner output. Optimum control of operation
frequency results in eliminating the consumption of
excessive electricity and providing the most
comfortable room environment.
INVERTERS HOW THEY WORK
Simple comparison of air conditioner operation control with inverter and Non-inverter.
Non-inver!er air condi!ioner repea!s working and s!opping opera!ion !o keep room
!empera!ure. 1here!ore, i! brings lower energy-saving and uncom!or!able opera!ion.
TRUE COMFORT
I Inverter Operation Image
PAM
Conventional
inverter
I Merits of PAM Control Power increased
Efficient voltage increase
realises increased power
Significant energy savings
Remarkable reduction in power
loss saves electricity
Limited power
Insufficient power
when needed
Limited energy savings
Electricity is wasted
Without PAM control With PAM control
Supply
voltage
Current
Time
Time
PAM adjusts the form of the current wave so that it becomes close to that of the supply
voltage wave. High harmonics are reduced and 98% of the electricity is utilized.
Magnetic torque
+
Reluctance torque
DC compressor
motor ( rotor )
Neodymium
magnets
PLY-P24BA PLY-P18BA PLY-P30BA PLY-P36BA optional
PCY-P24KA PCY-P18KA PCY-P30KA PCY-P36KA optional optional
optional PEY-P24JA PEY-P18JA
SUY-KA18VA
PEY-P30JA PEY-P36JA
SUY-KA24VA SUY-KA30VA SUY-KA36VA
optional
Joint Lap DC Motor
Mitsubishi Electric has developed a
unique motor, called the Poki-Poki
Motor in Japan, which is manufac-
tured using a joint lapping technique.
This innovative motor operates
based on a high-density, high-mag-
netic force, leading to extremely high
efficiency and reliability.
Rare Earth Magnet Rotor (Compressor)
An innovative motor with a rare earth magnet rotor is
equipped in the compressor to ensure excellent efficiency.
The rare earth magnet has a
residual magnetic flux density
threefold that of the previously
used ferrite magnet.
Grooved Piping
High-performance grooved piping is used in heat
exchangers to increase the heat exchange area.
PAM (Pulse Amplitude Modulation)
DC Fan Motor
A highly efficient DC motor drives the fan of the
outdoor unit. Efficiency is much higher than an
equivalent AC motor.
Reluctance DC Rotary Compressor
Powerful neodymium magnets are used in
the rotor of the reluctance DC motor. More
efficient operation is realised by strong mag-
netic and reluctance torques produced by
the magnets.
(SUY-KA24/30/36VA Only)
Grooved piping
Cross-sectional view
Pipe image
PAM is a technology that controls the current waveform so that it resembles the
supply voltage wave, thereby reducing loss and realising more efficient use of elec-
tricity. Using PAM control, 98% of the input power supply is used effectively.
Change in room
temperature
Optimum Control of frequency
keeps preset room temperature
Inverter air
conditioner
Time Compressor operation
Minimum power
operation
Constant room temperature
P
r e
s
e
t
t e
m
p
e
r a
t u
r e
Compressor operation
Change in room
temperature
On/off operation of compressor
keeps room temperature
Non-inverter
air conditioner
ON
Time
Full power
getting too hot getting too cool
P
r e
s
e
t
t e
m
p
e
r a
t u
r e
ON ON OFF OFF
SERIES
PLY
SERIES
Advancements in PLY series improve
style and performance for ensured
indoor comfort
Wide Airflow
Wide-angle outlets distribute air-
flow to all corners of the room, en-
suring the room is sufficiently
cooled/heated. Horizontal airflow
and a fan speed reduced by 20%
compared to conventional models
also contribute to increased com-
fort for occupants.
Conventional model
PLY-P88BA
Less Cold Draft
The horizontal airflow function
prevents cold drafts from striking
the body directly, thereby keep-
ing the body from becoming
over-chilled.
Automatic air-speed adjustment
An automatic air speed adjustment mode is provided in addition to
the four air-speed stages, of High, Medium 1, Medium 2, and Low.
Air speed can be changed freely in accordance with a difference
between the set temperature and the room temperature. The auto-
matic air speed adjustment mode offers quick cooling of a room in
high mode, such as at the starting up of cooling operation. After
the room temperature is stabilized, the low mode will be applied
automatically to maintain comfort.
Automatic vane shutter*
When the air conditioner is not
operating, the vane shutter closes
automatically to conceal the air
outlet and create an aesthetically
appealing flat surface.
Unit height of only 258mm (PLY-P18/24BA)
The high-power ceiling cas-
settes offer a wide-flow air
outlet that enables effective
air conditioning of rooms
with atrium ceilings up to
4.5m in height. The de-
mands of high-ceiling applications
such as halls, showrooms or shopping
malls can now be fully answered
thanks to this powerful yet highly effi-
cient airflow.
Wide-flow air outlet
Pure White color harmonized with the interior dcor
A "Pure White" color is adopted for the decoration panel and wired
remote controller so as to blend with any interior dcor.
Ceiling cassette models boast a slim body height for smooth and aes-
thetic installation even in narrow plenum spaces.
Quiet Operation
An improved airflow path and powerful high-
capacity flow fan contribute to the realisation of
quieter operation.
Power flow fan
Other Features
Maximum upward draining of 850mm
Wireless remote controller available
Duct flange for Fresh-air Intake
Branch duct
Automatic Grille Lowering
Function (Option)
Easy to use/Simple maintenance
An automatic grille lowering function capable
of stopping at eight different heights is avail-
able to simplify filter maintenance.
(comes with the automatic elevation panel)
1.2m
1.6m
2.0m
2.4m
2.8m
3.2m
3.6m
4.0m
Automatic
elevation to
4.0m
The i-see Sensor built into the optional corner
panel eliminates uneven temperature distribution
and reduces electricity consumption.
The i-see Sensor temperature-sensing technology
improves energy efficiency and enhances room comfort
The i-see Sensor is an innovative Mitsubishi Electric technology
that uses a radiation-based sensor to monitor temperature through-
out an entire room. When connected to the air conditioner control
panel, the i-see Sensor works to maximize room comfort.
The i-see Sensor rotates 90 at intervals of 5sec,
accurately measuring the temperature throughout
the room (covering entire floor space).
I i-see Sensor Operation
90
rotation
90
rotation
90
rotation
5sec
measurement
5sec
measurement
5sec
measurement
5sec
measurement
Sensible temperature control prevents excessive
cooling through pioneering control technology
By measuring the inlet temperature and floor temperature, tempera-
tures felt by the human body (sensible temperature) will be com-
puted. This allows the proper sensible temperature to always be
maintained through the suppression of excessive cooling.
Elevating (up-down)
controller
optional
PLY-P18/24/30/36BA
( i-see Sensor: optional )
Inverter Series
03-04
4-way Ceiling Cassette
High Low
Automatic air-
speed adjustment Medium 2 Medium 1
*
This feature will not activate when the vane is set
at the fixed position.
(When using the wireless remote controller, an extra setting is required.)

Vane shutter closes automatically
During operation When turned off
PLY-P18/24BA
PLY-P30/36BA
PLY-P18/24BA PLY-P30/36BA
8If required to set Low Ceiling Mode in a high humidity condition, please consult with dealers since
there is some risk of condensation.
3-way 2.7 3.0 3.0 3.6 4.5 3.5
4-way 2.5 2.7 2.7 3.2 4.5 3.5
ISpecification according to ceiling height
(PLY-P30/36BA)
Horizontal airflow prevents drafty feeling
(optional corner panel)
The i-see Sensor automatically controls over-cooling
by detecting the optimum temperatures.
Fixed condition Fixed condition
Temperature set at 26 27C,
without the i-see Sensor
Temperature set at 28C, with i-see Sensor
and automatic air- speed adjustment mode
Felt temperature: 26.5C Felt temperature: 28C
32C
23C
14C
28C
30 minutes
26.5C
Inlet temperature
Floor temperature
Felt temperature
28 C
30 minutes
26.5 C
Inlet temperature
Floor temperature
Felt temperature
No drops in felt temperature
Fixed condition Fixed condition
Felt temperature drops
Example When you want the felt temperature to be 28C.
With optional i-see
Sensor corner panel
The felt temperature drops according to
the drop in floor-level temperature. If the
floor-level temperature is not monitored
during long cooling operation, the felt
temperature becomes chilly.
Air temperature is adjusted according
to the floor temperature to keep the
felt temperature at 28C.
PCY
SERIES SERIES
A stylish indoor unit design and airflow
settings for both high- and low-ceiling
interiors expand installation possibilities
Stylish Indoor Unit Design
A stylish square-like design is adopted for
the indoor units of all models. As a result,
the units blend in better with the ceiling.
PC-GAKD
PCY-P88KA
Optional Drain Pump for
Full-capacity Models
The pumping height of
the optional drain pump
has been increased
from 400mm to 600mm,
expanding flexibility in
choosing unit location
during installation work.
Drainage outlet can
be 600mm above
ceiling surface
Drain pump installation
possible
Ceiling
surface
Equipped with Automatic Air-speed Adjustment
In addition to the conventional 4-speed setting, units are now
equipped with an automatic air-speed adjustment mode. This
setting automatically adjusts the air-speed to conditions that
match the room environment. At the start of cooling operation,
the airflow is set to high-speed to quickly cool the room. When
the room temperature reaches the desired setting, the
airflow speed is decreased automatically for stable comfort-
able cooling operation.
Start of cooling
After room
temperature is stabilised
Strong Gentle
Fresh Outside-air Intake
Airflow volume (m3/min)
50
0
50
100
150
200
250
300
0 1 2 3 4
S
t
a
t
ic
p
r
e
s
s
u
r
e
(
P
a
)
GOutside-air intake characteristics
PCY-P30/36KA
PCY-P18/24KA
Flockless vanes
With the adoption of flockless vanes, dirt and other impurities
can be cleaned off easily with mild household detergent.
optional optional
Ceiling-suspended
PCY-P18/24/30/36KA
PEY
SERIES SERIES
The thin, ceiling-concealed indoor units
of the PEY series are the perfect answer
for the air conditioning requirements of
buildings with minimum ceiling installation
space and wide-ranging external static
pressure. Energy-saving efficiency has
been improved, thereby reducing electricity
consumption and contributing to a further
reduction in operating cost.
Compact Indoor Units
For all models, unit height are unified to 250mm. Compared to the
previous model, the height size is reduced, allowing installation in
tight spaces, such as ceiling cavities or drop-ceilings.
Air Inlet
The units with bottom inlet make more noise than those with rear
inlet. It is recommended that the rear inlet be selected when install-
ing the units in the rooms that should be quiet such as bedrooms.
Wide Selection of Fan Speeds and External
Static Pressure
Five-stage external static pressure conversions and three fan
speed selections are available. Capable of being set to a maxi-
mum of 125Pa, units are applicable to a wide range of building
types.
1Rear inlet 2Bottom inlet
PEY-P18/24/30/36JA
optional optional
250mm
Ceiling-concealed
IExternal static pressure setting
Series
PEY-P
.
JA
18 24 30 36
35/50/70/100/125Pa
Reduction in height size
Air inlet
Air outlet
Air outlet
Air inlet
Inverter Series
05-06
Units are equipped with a knock-out hole that enables the in-
duction of fresh outside-air.
Inverter Series
07-08
CONTROL
TECHNOLOGIES
PAR-31MAA(Optional)
Easier to read thanks to use of a full dot liquid-crystal display with
backlight, and easier to use owing to adopting a menu format that
has reduced the number of operating buttons.
Energy-efficient Control
Operation Control Functions
Easy To Read & Easy To Use
Multi-language Display
Control panel operation in eight
different languages
Display Example [Operation Mode]
Full Dot LCD
Using a temperature that is 1C higher for cooling results in a 10% reduction in
power consumption.* Temperature Range Restriction limits the maximum and
minimum temperature settings, contributing to the prevention of overcooling. *In-
house calculations
Temperature Range Restriction
prevents overcooling
Temperature
Range
Restriction
When using Auto-off Timer, even if one forgets to turn off the unit, operation stops
automatically after the preset time elapses, thereby preventing wasteful opera-
tion. Auto-off Timer can be set in 10-minute units, in a range between 30 minutes
and 4 hours. Eliminates all anxiety about forgetting to turn off the unit.
Turns cooling off
automatically after preset time
elapses
Auto-off
Timer
After adjusting the temperature for initialing on a hot day, it is easy to forget to
return the temperature setting to its original value. The Auto-return function auto-
matically resets the temperature back to the original setting after a specified period
of time, thereby preventing overcooling. The Auto-return activation time can be set
in 10-minute units, in a range between 30 and 120 minutes.
*Auto-return cannot be used when Temperature Range Restrictions is in use.
Prevents wasteful operation by
automatically returning to the preset
temperature after specified operating time
Auto-return
This function monitors the room temperature and automatically activates the
cooling mode when the temperature rises above the preset maximum tempera-
ture setting.
Keep desired room temperatures
automatically
Night
Setback
Choose the desired language,
among the following languages.
Multi-
Ianguage
Full Dot Liquid-crystal Display Adopted
[English] [Italian] [German] [Spanish] [Swedish] [Russian] [Portuguese] [French]
Cooling/Dry (Setting example of minimum temp. in 25C)
Lower temperature limit
Possible temperature range setting
19(C) 30(C)
30(C) 25(C)
To prevent excessive cooling Lower temperatures cannot
be selected
Meeting room Changing room Recommended for
In addition to operation start/stop, the operation mode, temperature setting and air-
flow direction can be locked. Unwanted adjustment of temperature settings is pre-
vented and an appropriate temperature is constantly maintained, leading to energy
savings. This feature is also useful in preventing erroneous operation or tampering.
Fixed temperature setting promotes
energy savings
Operation
Lock
The Weekly Timer enables the setting of operation start and finish times and adjust-
ing the temperature as standard features. Up to 8 patterns per day can be set, pro-
viding operation that matches the varying conditions of each period, such as the
number of customers in the store.*Weekly Timer cannot be used when On/Off Timer is in use.
Set up to 8 patterns per day including
temperature control
Weekly
Timer
Auto-descending panel operation is available as an option. Panels can be
lowered/raised using a button on the wired remote controller. Filter cleaning can
be performed easily.
Easily raise/lower panels using
the remote controller
Auto-
descending
Panel Operation
(4-way ceiling cassette)
Office Restaurant
Office Restaurant
Recommended for
PAR-31MAA
The adoption of dot liquid-crystal display (LCD) technology and a
large display screen for the control panel optimises visibility. Op-
eration and control status are easily read at a glance.
Energy-efficient Control
Operation Control Functions
Easy to Read/Easy to Use
Multi-language Display
Control panel operation in eight
different languages
Display Example [Operation Mode]
Dot LCD
Choose the desired language, among the
following languages.
Multi-
Ianguage
Dot Liquid-crystal Display Adopted
PAR-21MAA
User-friendly Deluxe Remote Controller with Excellent
Operability and Visibility
PAR-21MAA
Advanced MA Remote Controller
A Progressive Step in the Evolution of Air Conditioning Control
Reassuring Troubleshooting Navigation Function
Contact Details Displayed When Abnormality Occurs
Easily contact a service company when there is a problem.
The telephone number of a service company and other information can be input
and stored in advance. When a problem occurs, the contact details are dis-
played automatically, and a call for help can be made without delay.
Set the time for the air conditioner to turn off automatically. The timer can be set
in the range from 30 minutes up to 4 hours in 30-minute intervals.
The Simple Timerstarts/stops in units of 1 hour in a 72-hour periodis set at
the time of shipment from the factory. It can be changed to the Auto-off Timer
function using the remote controller.
Automatically turns off
air conditioner
Auto-off
Timer
Units can be set so that the operation mode cannot be changed. When Opera-
tion Lock is activated, new temperature setting commands are not accepted,
thereby ensuring that the unit runs in the specified (locked in) temperature range.
This promotes energy savings and prevents erroneous/ mischievous operation.
Only the administrator can change settings when using the Operation Lock mode.
Prevent operation settings
from being changed
Operation
Lock
Set the upper and lower limits for the temperature range during operation. Exces-
sive cooling is prevented, leading to increased energy savings.
Air conditioner operation restricted
to within a specified operating range
Temperature
Range
Restriction
Control temperature on a weekly basis
Temperature settings and On/Off control can be managed over a period of one
week using the Weekly Timer. Up to eight setting patterns per calendar day are
possible.
Introduced in response to
market demand
Weekly
Timer
[English] [Italian] [German] [Spanish]
[Japanese] [Russian] [Chinese] [French]
Cooling/Dry
Recommended for
Lower temperature limit
Possible temperature range setting
19(C) 30(C)
30(C) 25(C)
To prevent excessive cooling Lower temperatures cannot
be selected
(Setting example of minimum temp. in 25C)
Busy
hours
Off-peak
hours
4
26
25
24
23
22
0
10 12 14 16 18 20 22 24
T
e
m
p
e
r
a
tu
r
e
s
e
ttin
g
(
C
)
Opening time
Lunch time Dinner time
7-patterns setting
Closing time
Set to lower temperature Set to higher temperature
1
2
3 5
6 7
(Time)
(Results of cooperative study with Japan Facility Solutions, Inc.)
Meeting room Recommended for Changing room
Recommended for
Computer server facility
Office School
Hospital
Public hall
Recommended for
Computer server facility
Office School
Hospital
Public hall
Setting Example (restaurant in summer time)
Busy
hours
5
26
25
24
23
22
0
10 12 14 16 18 20 22 24
T
e
m
p
e
ra
tu
re
s
e
ttin
g
(C
)
Opening
time
Lunch time
Preparation
Dinner time
8-patterns setting
Closing time
Set to lower temperature Set to higher temperature
1
2 4
3
6
7 8
(Time)
*Joint research conducted with Japan Facility Solutions, Inc.
Off-peak
hours
Setting Example (restaurant in summer time)
Ceiling-Concealed Type
Models
kW
CMM
CFM
kW
BTU/h
Cooling capacity
Total input
Indoor
unit
Outdoor
unit
EER
Model name
Fan motor output
Airflow(low-mid-high)
External static pressure
Operation control & thermostat
Noise level (low-mid-high)
Unit drain pipe O.D.
Dimensions
Weight
Model name SUY-KA18VA SUY-KA36VA SUY-KA30VA SUY-KA24VA
PEY-P18JA
425-510-600
Pa
dB(A)
mm
mm
mm
W
D
12-14.5-17
5.3(2.8-5.4)
18000
kW 1.57
W/W 3.38
PEY-P18JA
620-740-885
17.5-21-25
850-1025-1200
24-29-34
30-34-39 33-38-42
732
External finish Munsell 3.0Y 7.8/1.1
Refrigerant (R410A) control Liner Expansion Valve
Compressor output
Protection devices
Discharge thermo, Comp.shell thermo, Over current protection, (Compressor)
Over heat protection, Over current protection, (Fan motor)
mm H 250
46(1625)
kg
kW
1040-1225-1485
29.5-35.5-42
0.085 0.121
32
7
36-40-44
38
1.2
39
1400
0.244
30-35-39
1100 900
29 27
0.9
Fan motor output kW 0.06 0.05
Airflow CMM(CFM) 51(1800) 34(1200)
54 56 Noise level
Dimensions
dB(A) 58 51
47 50 Weight kg 51 33
15 MAX.height difference m 12
30 MAX.piping length m 20
Liquid:9.52 Gas:15.88 Pipe size O.D. mm Liquid:6.35 Gas:12.7
Chargeless piping length m
W 840 mm 800
D 330 mm 285
H 880 mm 550
Power Supply
External finish
PEY-P36JA
10.6(4.1-10.7)
36000
3.33
3.18
PEY-P36JA
Gralvanized sheet
35-50-70-100-125
Remote control & Built-in
PEY-P30JA
8.8(4.1-9.7)
30000
2.5
3.52
PEY-P30JA
PEY-P24JA
7.1(3.6-8.9)
24000
3.51
PEY-P24JA
2.02
1ph 220-240V 50Hz / 1ph 220V 60Hz
System Controls Versatile system controls can be realised by using optional parts, relay circuits, control panels, etc.
Inverter Series
09-10
SPECIFICATIONS
FOR INDOOR UNITS
2-remote Controller
Control
With two remote controllers, control
can be performed locally and
remotely from two locations.
Operation Control by
Level Signal
Air conditioner can be started/
stopped remotely. In addition,
On/Off operation by local remote
controller can be prohibited/permitted.
Operation Control by
Pulse Signal
Remote Display of
Operating Status
Operating status can be
displayed at a remote location.
Allows On/Off operation with
timer
*For control by an external
timer, refer to B Operation
Control by Level Signal.
Timer Operation
Wired Remote Controller
PAR-31MAA
PAR-21MAA
Wireless Remote Controller
PAR-SL97A-E (for PEY)
Wireless Remote Controller Kit for PCY
PAR-SL94B-E
Adapter for remote On/Off
PAC-SE55RA-E
Relay box (to be purchased locally)
Remote control panel (to be purchased
locally)
Standard functions of PAR-31MAA
A
B
C
D
E
Details Major Optional Parts Required
System Examples
Wired remote controller Wireless remote controller
Up to two remote controllers can be
connected to one group.
Both wired and wireless remote controllers
can be used in combination.
Operation other than On/Off (e.g., adjust-
ment of temperature, fan speed, and airflow)
can be performed even when remote
controller operation is prohibited.
Timer control is possible with an external
timer.
Connector cable for remote display
PAC-SA88HA-E/ PAC-725AD
(10 pcs. x PAC-SA88HA-E)
Relay box (to be purchased locally)
Remote control panel (to be purchased
locally)
The pulse signal can be turned On/Off.
Operation/emergency signal can be
received at a remote location.
Operation/emergency signal can be
received at a remote location (when
channeled through the PAC-SF40RM
no-voltage signal, when channeled through
the PAC-SA88HA-E DC 12V signal).
Weekly Timer:
On/Off and up to 8 pattern temperatures can
be set for each calendar day. (Initial setting)
On/Off Timer:
On/Off can be set once each within 72 hr.
in intervals of 5-minute units.
Auto-off Timer:
Operation will be switched off after a certain
time elapse. Set time can be changed from
30 min. to 4 hr. at 10 min. intervals.

*Simple Timer and Auto-off Timer
cannot be used at the same time.
Remote display panel (to be purchased
locally)
Connector cable for remote display
PAC-SA88HA-E/ PAC-725AD
(10 pcs. x PAC-SA88HA-E)
Relay box (to be purchased locally)
Remote operation adapter
PAC-SF40RM
*Unable to use with wireless remote controller
PAR-31MAA
PAR-21MAA PAR-31MAA
PAR-21MAA
(Example of 1 : 1 system)
(Example of 1 : 1 system)
Relay box (to be purchased) locally)
Relay box (to be purchased) locally)
Adapter for
remote
On/Off
Adapter for
remote
On/Off
PAR-SL97A-E
PAR-SL97A-E
(Example of 1 : 1 system)
PAR-31MAA
(Example of 1 : 1 system x 2)
Relay box (to be purchased locally)
(Example of 1 : 1 system x 2)
* Set "Main" and "Sub"
remote controllers. * When using wired and
wireless remote controllers
PAR-SL97A-E
Remote
display
panel
Remote
display
panel PAR-31/
21MAA
Remote
control
panel
Remote
control
panel Wired remote
controller
Connector
cable for
remote
display
Connector
cable for
remote
display
PAR-SL97A-E
(Example of 1 : 1 system x 2)
Relay box (to be purchased locally)
(Example of 1 : 1 system x 2)
Remote
control
panel
Remote
control
panel Wired remote
controller
Remote operation adapter/
Connector cable for remote display +
Relay box
Remote operation adapter/
Connector cable for remote display +
Relay box
MAJOR SYSTEM CONTROL
PAR-31MAA Control
PAR-21MAA Control
System Group Control
M-NET Connections
PAR-31MAA (Wired remote controller)
PAR-21MAA (Wired remote controller)
<SUY Series Outdoor Unit>
MAC-333IF-E (Interface)
PAR-31MAA (Wired remote controller)
PAR-21MAA (Wired remote controller)
A
B
C
Details Major Optional Parts Required
System Examples
PLY,PCY,PEY Series Indoor Unit
SUY Series Outdoor
Indoor Unit
Outdoor Unit
Standard equipment (for indoor units
compatible with wired remote controllers)
One remote controller can control plural air
conditioners with the same settings
simultaneously.
One remote controller can control up to 16
refrigerant systems.
Up to two remote controller can be
connected.
<SUY Series Outdoor Unit>
MAC-333IF-E
MELANS System controller
PAC-SC51KUA (power supply unit)
Group of air conditioners can be controlled
by MELANS system controller (M-NET).
PAR-31MAA
PAR-21MAA
MAC-333IF-E
Outdoor
unit
Indoor unit
MAC-333IF-E MELANS
system controller
(AG-150A etc)
PAC-SC51KUA
Power supply
unit
City Multi
indoor unit
Outdoor
unit
Indoor unit
PAR-31MAA
PAR-21MAA
PAR-31MAA
PAR-21MAA
PAR-31MAA
PAR-21MAA
Ceiling-Suspended Type
Models
kW
CMM
CFM
kW
BTU/h
Cooling capacity
Total input
Indoor
unit
Outdoor
unit
EER
Model name
Fan motor output
Airflow(low-mid2-mid1-high)
External static pressure
Operation control & thermostat
Noise level (low-mid2-mid1-high)
Unit drain pipe I.D.
Dimensions
Weight
Model name SUY-KA18VA SUY-KA36VA SUY-KA30VA SUY-KA24VA
PCY-P18KA
0.095
565-600-635-705
Pa
dB(A)
mm
mm
mm
W
D
16-17-18-20
5.3(2.8-5.4)
18000
kW 1.51
W/W 3.51
PCY-P18KA
565-635-705-775
16-18-20-22
0.16
850-920-990-1060
24-26-28-30
34-36-40-42 39-41-43-45
680
External finish Munsell 3.0Y 7.8/1.1
Refrigerant (R410A) control Liner Expansion Valve
Compressor output
Protection devices
Discharge thermo, Comp.shell thermo, Over current protection, (Compressor)
Over heat protection, Over current protection, (Fan motor)
mm H 230
46(1625)
kg
kW
32
955-1025-1130-1200
27-29-32-34
26
7
42-44-46-48
37
1.2
40
1280 1600
34-36-38-40
0.9
Fan motor output kW 0.06 0.05
Airflow CMM(CFM) 51(1800) 34(1200)
54 56 Noise level
Dimensions
dB(A) 58 51
47 50 Weight kg 51 33
15 MAX.height difference m 12
30 MAX.piping length m 20
Liquid:9.52 Gas:15.88 Pipe size O.D. mm Liquid:6.35 Gas:12.7
Chargeless piping length m
W 840 mm 800
D 330 mm 285
H 880 mm 550
Power Supply
External finish
PCY-P36KA
10.6(4.1-10.7)
36000
3.13
3.39
PCY-P36KA
Munsell 6.4Y 8.9/0.4
0 (direct blow)
Remote control & Built-in
PCY-P30KA
8.8(4.1-9.7)
30000
2.6
3.38
PCY-P30KA
PCY-P24KA
7.1(3.6-8.9)
24000
3.38
PCY-P24KA
2.1
1ph 220-240V 50Hz / 1ph 220V 60Hz
Ceiling Cassette Type
Models
kW
CMM
CFM
kW
BTU/h
Cooling capacity
Total input
Indoor
unit
Outdoor
unit
EER
Model name
Fan motor output
Airflow(low-mid2-mid1-high)
External static pressure
Operation control & thermostat
Noise level (low-mid2-mid1-high)
Unit drain pipe O.D.
Dimensions
Weight ( ):Panel
( ):Panel
Model name SUY-KA18VA SUY-KA36VA SUY-KA30VA SUY-KA24VA
PLY-P18BA
425-460-495-565
Pa
dB(A)
mm
mm
mm
W
D
12-13-14-16
5.3(2.8-5.4)
18000
kW 1.47
W/W 3.61
PLY-P18BA
495-565-635-705
14-16-18-20
705-775-885-990
20-22-25-28
28-30-32-34 33-35-38-41
840(950)
840(950)
External finish Munsell 3.0Y 7.8/1.1
Refrigerant (R410A) control Liner Expansion Valve
Compressor output
Protection devices
Discharge thermo, Comp.shell thermo, Over current protection, (Compressor)
Over heat protection, Over current protection, (Fan motor)
mm H
46(1625)
kg
kW
850-920-1025-1130
24-26-29-32
0.05
32
7
37-39-41-44
24(6)
1.2
26(6)
0.12
258(35) 298(35)
28-29-30-32
22(6) 19(6)
0.9
Fan motor output kW 0.06 0.05
Airflow CMM(CFM) 51(1800) 34(1200)
54 56 Noise level
Dimensions
dB(A) 58 51
47 50 Weight kg 51 33
15 MAX.height difference m 12
30 MAX.piping length m 20
Liquid:9.52 Gas:15.88 Pipe size O.D. mm Liquid:6.35 Gas:12.7
Chargeless piping length m
W 840 mm 800
D 330 mm 285
H 880 mm 550
Power Supply
External finish
PLY-P36BA
10.6(4.1-10.7)
36000
3.13
3.39
PLY-P36BA
Munsell 6.4Y 8.9/0.4
0 (direct blow)
Remote control & Built-in
PLY-P30BA
8.8(4.1-9.7)
30000
2.36
3.73
PLY-P30BA
PLY-P24BA
7.1(3.6-8.9)
24000
3.51
PLY-P24BA
2.02
1ph 220-240V 50Hz / 1ph 220V 60Hz
Inverter Series
11-12
EXTERNAL
DIMENSIONS
Unit : mm
1
0
69
800
302.5
500 Bolt pitch for installation
150
22.3
Handle
5
5
0
2
8
0
1
6
4
.5
9
9
.5
170.5
23
Service panel
Service port
2
8
5
3
4
4
.54
4
400
Air in
Air out
Air in
1
7
.5
B
o
lt p
itc
h
fo
r
in
s
ta
lla
tio
n
3
0
4
~
3
2
5
40
Liquid refrigerant pipe joint
Gas refrigerant pipe joint
4
3
3
5
2 holes 10X21
Drain hole
SUY-KA18VA
OUTDOOR UNIT
SUY-KA24VA SUY-KA30VA SUY-KA36VA
OUTDOOR UNIT
417.5
40
42 Drain hole
175 500
3
3
0
5
0
Air in
Air out
2-holes 10 21
3
6
0
840
109
81
8
8
0
4
5
2
Service panel
9
9
.5
1
6
4
.5
195
3
5
4
4
Liquid refrigerant
pipe joint
Gas refrigerant
pipe joint
42
B
o
lt p
itc
h
fo
r
in
s
ta
lla
tio
n
Air in
Unit : mm
Ceiling hole
Branch duct hole
Indoor unit/Outdoor
unit connecting
terminal block

Indoor power supply
terminal block(optional part)
Branch duct hole
Fresh air
intake hole
Ceiling hole
Suspension bolt pitch
Suspension bolt pitch
Remote controller
terminal block
(7.5)
(7.5)
605 +35
- 5
620
160
160
160
840
150
90CD
840
187.5
20~45 860~910 20~45
810
20~45
860~910
20~45
24160
950
Cut out hole
Cut out hole
Burring hole pitch Burring hole
175
167
130
100
70
155
350
90 100 100 90
Detail connecting of branch duct
14- 2.8
150
377 284 60 Drain pipe
Ceiling
Grille
Power supply wire,
Indoor unit/Outdoor unit
connecting wire entry
Control wire entry
Keep approximately
10 to 15mm space
between unit ceiling
and ceiling slab.
Suspension bolt
M10 or W3/8
A
17 +5 0
B
35
190
156
105
140
50~70 Suspension bolt
lower edge
170
Models B A C D
241 258
80
85
74
298
77
281
PLY-P18BA
PLY-P24BA
PLY-P30BA
PLY-P36BA
PLY-P18BA PLY-P24BA PLY-P30BA PLY-P36BA
INDOOR UNIT
950
Refrigerant pipe
Refrigerant pipe
(liquid)
(gas)
INDOOR UNIT
When drain socket
is installed
(Drainage)
(
PCY-P30KA PCY-P36KA
233
5
10
51
246
180
200
236
84
88
195
230
57
254
476
680
182 85
1518
1600 2 2
1493
Air outlet
Air intake
(gas)
(liquid)
PCY-P18KA PCY-P24KA
INDOOR UNIT
Air intake
Air outlet
84
88
195
230
57
254
476
680
182 85
1198
1280 2 2
1173
When drain socket
is installed
233
5
10
51
246
A
B
236
(Drainage)
(gas)
(liquid)
( (
PEY-P18JA PEY-P24JA PEY-P30JA PEY-P36JA
INDOOR UNIT
Models
PEY-P30JA
PEY-P36JA
PEY-P24JA
PEY-P18JA
A
900
1100
1400
954
B
1154
1454
860
D
1060
1360
9
E
11
14
1200
C
1500
1000
1300
1000
F
800
1358
1058
G
858
Models
PCY-P24KA
PCY-P18KA
A
184
180
203
B
200
5
7
7
8
2
5
0
3
3
1
2
2
15
2
4
57
10
1
0
0
1
0
0
x
(E
-1
)=
F
A
B
(S
u
s
p
e
n
s
io
n
b
o
lt p
itc
h
)
C
2
3
643(Suspension bolt pitch)
3
0
2
0
D
(D
u
c
t)
1
7
8
(D
u
c
t)
4
0
2
3
10
32 700
732
136 67
356
1
0
0
2
1
7
Suspension bolt hole
4-14x30 Slot
Air
outlet
Air
inlet
Refrigerant piping
Flare connection(liquid)
Refrigerant piping
Flare connection(gas)
Control box
Terminal block
(Indoor/Outdoor
connecting line)
Terminal block
(Remote controller
transmission line)

2xE- 2.9
2x2- 2.9
Drain pipe(O.D. 32)
Inverter Series
13-14
SUY-KA
Upper limit (DB)
Lower limit (DB)
46C
18C
Cooling
Guaranteed Operating Range
Sound Pressure Level
Sound pressure measurements were conducted in an anechoic chamber.
The actual noise level depends on the distance from the unit and the acoustic environment.
Single-phase, 220-240V Single-phase, 220-240V 50Hz
Single-phase, 220V Single-phase, 220V 60Hz
Notes for All Specifications
Rating conditions
Cooling - Indoor: 27C (80F) DB, 19C (66F) WB
Outdoor: 35C (95F) DB
Refrigerant piping length (one-way): 7.5m (25ft.)
Total input based on the indicated voltage (indoor/outdoor)
Indoor Outdoor
Refrigerant Piping
SUY-KA18
SUY-KA24
12
15
20
30
SUY-KA30
SUY-KA36
15
15
30
30
Liquid: 9.52
Gas: 15.88
Liquid: 9.52
Gas: 12.7
Liquid: 6.35
Gas: 15.88
Liquid: 9.52
Gas: 15.88
t 0.8
t 1.0
t 0.8
t 0.8
t 0.8
t 1.0
t 0.8
t 1.0
Thickness (mm) Pipe size OD (mm) Capacity
Between indoor & outdoor units
Max. height difference (m) Max. piping length (m)
Amount of Necessary Refrigerant ( R410A: kg)
SUY-KA18
SUY-KA24
SUY-KA30
SUY-KA36
1.2
2.0
2.1
2.5
0.05
0.06
0.06
0.06
0.12
0.16
0.16
0.16
0.2
0.26
0.26
0.26

0.36
0.36
0.36

0.36
0.46
0.46
Xg =15g/m (length-7) m
Xg =20g/m (length-7) m
30m 25m 20m 15m 10m 7m
Factory charged Additional charged
Calculation Piping length
NOTICE
IDo not install indoor units in areas (e.g., mobile phone base stations) where the emission of VOCs such as phthalate
compounds and formaldehyde is known to be high as this may result in a chemical reaction.
IWhen installing or relocating or servicing the air conditioners, use only the specified refrigerant (R410A) to charge the
refrigerant lines.
Do not mix it with any other refrigerant and do not allow air to remain in the lines.
If air is mixed with the refrigerant, then it can be the cause of abnormal high pressure in the refrigerant lines, and may
result in an explosion and other hazards.
The use of any refrigerant other than that specified for the system will cause mechanical failure or system malfunction or
unit breakdown. In the worst case, this could lead to a serious impediment to securing product safety.
Outdoor Unit Installation Location
A
D
C
A
B
A
C
A
C
B
SUY-KA18VA SUY-KA24VA
SUY-KA30VA
SUY-KA36VA
Outdoor unit
Ventilation and service space
100 mm or more 350 mm or more
Basically open 100 mm or more without any obstruction in front and both sides
of the unit.
200 mm or more (Open two sides of left, eight, or rear side.)
I SUY-KA18VA
A B
100 mm or more 350 mm or more 500 mm or more
I SUY-KA24VA SUY-KA30VA SUY-KA36VA
A B C
C
D
When the piping is to be attached to a wall containing metals (tin plated) or metal
netting, use a chemically treated wooden piece 20mm or thicker between the
wall and the piping or wrap 7 to 8 tums of insulation vinyl tape around the piping.
Units should be installed by licensed contractor accordingly to local code
requirement.
Optional Parts
Part name Model name Application name
PCY-P24/30/36 PAC-SH84DM-E
PCY-P18 PAC-SH85DM-E
PLY-P PAC-SH65OF-E Flange for fresh-air intake
Drain pump
All indoor units MAC-333IF-E
PLY-P / PEY-P PAR-SL97A-E
M-NET&Terminal interface
Wireless remote controller
PEY-P PAR-SA9CA-E
Wireless remote controller
signal receiver
PLY-P PAR-SA9FA-E
PCY-P18/24 PAC-SH89KF-E
PCY-P30/36 PAC-SH90KF-E
PLY-P PAC-SH59KF-E
PEY-P18 PAC-KE92TB-E
High efficiency filter element
Filter box PEY-P24 PAC-KE93TB-E
PEY-P30/36 PAC-KE94TB-E
PLY-P PAC-SA1ME-E
PLY-P PAC-SH51SP-E
i-see sensor corner panel
Shutter plate
PLY-P PAC-SH53TM-E Multi-function casement
All indoor units PAC-SE55RA-E Remote On/Off adaptor
All indoor units PAC-SF40RM-E Remote operation adaptor
All indoor units PAC-SE41TS-E Remote sensor
PLY-P PAC-SH48AS-E Space panel
All indoor units PAC-SA88HA-E Connector cable for remote display
Wired remote controller
Air discharge guide
Multiple remote controller adaptor
All indoor units PAR-31MAA
All indoor units PAR-21MAA
SUY-KA18 MAC-881SG
SUY-KA24/30/36 MAC-886SG
PCY-P PAR-SL94B-E
Wireless remote controller kit
(Sender & Receiver)
PAC-725AD All indoor units
High efficiency filter