You are on page 1of 17

Nokia Siemens Networks

GSM/EDGE BSS, rel.


RG10(BSS), operating
documentation, issue 06
Flexi EDGE BTS Dual TRX Module (EXxx)
Description
DN70178382
Issue 4-0
Approval Date 2009/10/16
2 DN70178382
Issue 4-0
Flexi EDGE BTS Dual TRX Module (EXxx) Description
Id:0900d8058063dfd0
The information in this document is subject to change without notice and describes only the
product defined in the introduction of this documentation. This documentation is intended for the
use of Nokia Siemens Networks customers only for the purposes of the agreement under which
the document is submitted, and no part of it may be used, reproduced, modified or transmitted
in any form or means without the prior written permission of Nokia Siemens Networks. The
documentation has been prepared to be used by professional and properly trained personnel,
and the customer assumes full responsibility when using it. Nokia Siemens Networks welcomes
customer comments as part of the process of continuous development and improvement of the
documentation.
The information or statements given in this documentation concerning the suitability, capacity,
or performance of the mentioned hardware or software products are given "as is" and all liability
arising in connection with such hardware or software products shall be defined conclusively and
finally in a separate agreement between Nokia Siemens Networks and the customer. However,
Nokia Siemens Networks has made all reasonable efforts to ensure that the instructions
contained in the document are adequate and free of material errors and omissions. Nokia
Siemens Networks will, if deemed necessary by Nokia Siemens Networks, explain issues which
may not be covered by the document.
Nokia Siemens Networks will correct errors in this documentation as soon as possible. IN NO
EVENT WILL Nokia Siemens Networks BE LIABLE FOR ERRORS IN THIS DOCUMENTA-
TION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL, DIRECT, INDI-
RECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES, SUCH AS BUT NOT LIMITED
TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESS OPPORTUNITY
OR DATA,THAT MAY ARISE FROM THE USE OF THIS DOCUMENT OR THE INFORMATION
IN IT.
This documentation and the product it describes are considered protected by copyrights and
other intellectual property rights according to the applicable laws.
The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademark
of Nokia Corporation. Siemens is a registered trademark of Siemens AG.
Other product names mentioned in this document may be trademarks of their respective
owners, and they are mentioned for identification purposes only.
Copyright Nokia Siemens Networks 2010. All rights reserved
f Important Notice on Product Safety
Elevated voltages are inevitably present at specific points in this electrical equipment.
Some of the parts may also have elevated operating temperatures.
Non-observance of these conditions and the safety instructions can result in personal
injury or in property damage.
Therefore, only trained and qualified personnel may install and maintain the system.
The system complies with the standard EN 60950 / IEC 60950. All equipment connected
has to comply with the applicable safety standards.
The same text in German:
Wichtiger Hinweis zur Produktsicherheit
In elektrischen Anlagen stehen zwangslufig bestimmte Teile der Gerte unter Span-
nung. Einige Teile knnen auch eine hohe Betriebstemperatur aufweisen.
Eine Nichtbeachtung dieser Situation und der Warnungshinweise kann zu Krperverlet-
zungen und Sachschden fhren.
Deshalb wird vorausgesetzt, dass nur geschultes und qualifiziertes Personal die
Anlagen installiert und wartet.
Das System entspricht den Anforderungen der EN 60950 / IEC 60950. Angeschlossene
Gerte mssen die zutreffenden Sicherheitsbestimmungen erfllen.
DN70178382
Issue 4-0
3
Flexi EDGE BTS Dual TRX Module (EXxx) Description
Id:0900d8058063dfd0
Table of Contents
This document has 17 pages.
1 Summary of changes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
2 Dual TRX Module (EXxx). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
3 Dual TRX Module (EXxx) main blocks. . . . . . . . . . . . . . . . . . . . . . . . . . 10
4 Dual TRX Module (EXxx) power requirements . . . . . . . . . . . . . . . . . . . 12
5 Dual TRX Module (EXxx) interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
6 Dual TRX Module (EXxx) dimensions and weight . . . . . . . . . . . . . . . . . 15
7 Dual TRX Module (EXxx) LED indications. . . . . . . . . . . . . . . . . . . . . . . 16
8 Contents of the Dual TRX Module (EXxx) delivery . . . . . . . . . . . . . . . . 17
4 DN70178382
Issue 4-0
Flexi EDGE BTS Dual TRX Module (EXxx) Description
Id:0900d8058063dfd0
List of Figures
Figure 1 Dual TRX Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Figure 2 Dual TRX Module main blocks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Figure 3 Flexi EDGE Dual TRX Module (EXxx) front panel connectors and labels .
13
DN70178382
Issue 4-0
5
Flexi EDGE BTS Dual TRX Module (EXxx) Description
Id:0900d8058063dfd0
List of Tables
Table 1 Dual TRX Module (EXxx) input voltage range . . . . . . . . . . . . . . . . . . . 12
Table 2 Dual TRX Module (EXxx) power consumption . . . . . . . . . . . . . . . . . . . 12
Table 3 Flexi EDGE Dual TRX Module (EXxx) front panel connectors, cable types
and interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Table 4 EXxx dimensions and weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Table 5 Dual TRX Module LED indications . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Table 6 Flexi EDGE Dual TRX Module (EXxx) delivery contents . . . . . . . . . . . 17
6 DN70178382
Issue 4-0
Flexi EDGE BTS Dual TRX Module (EXxx) Description
Id:0900d8058063dfd0
DN70178382
Issue 4-0
7
Flexi EDGE BTS Dual TRX Module (EXxx) Description Summary of changes
Id:0900d8058063dfba
1 Summary of changes
Changes between issues 4-0 and 3-0
Updated chapters:
Dual TRX Module (EXxx) was updated with hardware support information. A note
about installation was added.
Dual TRX Module (EXxx) power requirements were updated
Dual TRX Module (EXxx) LED indications were updated
Contents of the Dual TRX Module (EXxx) delivery was updated.
Changes between issues 3-0 and 2-0
Updated chapters:
Dual TRX Module (EXxA) updated with information on Intelligent Downlink Diversity
(IDD) TRX. The figure Isometric view of the Dual TRX Module updated.
Module dimensions and weights updated with information on Dual TRX weight.
Contents of the EXxA delivery updated with information on preinstalled screws.
Changes between issues 2-0 and 1-0
New chapters:
Summary of Changes added.
Updated chapters:
Dual TRX Module (EXxA) main blocks added the Fan Module to the bulleted list.
Dual TRX Module (EXxA) power requirements Table 2 updated with explanations
of terms maximum, nominal, idle and one PA in use.
Dual TRX Module (EXxA) interfaces added two notes to table 3.
Dual TRX Module (EXxA) LED indications Table 5 updated with information on
cycling colours.
8 DN70178382
Issue 4-0
Flexi EDGE BTS Dual TRX Module (EXxx) Description
Id:0900d8058063db4e
Dual TRX Module (EXxx)
2 Dual TRX Module (EXxx)
The Dual TRX Module (EXxx) is a two-carrier TRX unit. The module contains the
common (2 carrier) baseband part and two separate RF parts for two transceivers
(transmitter and receiver chains) and space for two optional Wideband Combiner
Modules (Ewxx).
The Dual TRX Module (EXxB) hardware can simultaneously support the following future
BSS features:
Full Voice services over Adaptive Multi-user Orthogonal Sub channels (VAMOS)
Enhanced General Packet Radio Service Evolution (EGPRS2)
The Dual TRX Module (EXxx) is used as:
a combined module with the Dual Duplexer Module (ERxx), making a logical Sector
Module
or a stand-alone TRX module with the Remote Tune Combiner (ECxA) Module
or a stand-alone extension TRX module.
The Dual TRX Module and System Module (ESMA) communication is managed through
a single Ethernet interface. Each transceiver within the Dual TRX Module can be sepa-
rately activated with a licence key at the BSC.
The Dual TRX Module contains two transceivers that can be used:
as a separate TRX in the same sector
as a separate TRX in different sectors
or as a Double Power TRX.
or as an Intelligent Downlink Diversity (IDD) TRX.
There are separate Dual TRX Modules for each frequency band that Flexi EDGE BTS
supports:
EXTx GSM800
EXGx GSM900
EXDx GSM1800
EXPx GSM1900
See the following figure for an isometric view of the Dual TRX Module.
DN70178382
Issue 4-0
9
Flexi EDGE BTS Dual TRX Module (EXxx) Description Dual TRX Module (EXxx)
Id:0900d8058063db4e
Figure 1 Dual TRX Module
g The installation instructions for EXxA are the same as for EXxB.
DN70185036
10 DN70178382
Issue 4-0
Flexi EDGE BTS Dual TRX Module (EXxx) Description
Id:0900d8058063db59
Dual TRX Module (EXxx) main blocks
3 Dual TRX Module (EXxx) main blocks
The Dual TRX Module (EXxx) includes the following functional blocks:
Baseband
TRX, O&M, telecom and digital signal processing (DSP)
Ethernet interface for control, user and baseband hopping data
Synchronisation
Digital up/down conversion and filtering
TX and RX data conversion
TX Double Power support
Intelligent Downlink Diversity (IDD)
4-way Uplink Diversity support
RX 4-Way Interference Reject Combining (IRC) support
Temperature management
Power supply
Power distribution of TRX internal supply voltages
Transmitter
Direct conversion from TX interface to TX RF
Digital power control
TX Double Power and IDD support
Receiver
Dual down-conversion from RX RF to RX interface
Diversity reception
Digital Automatic Gain Control (AGC)
Synthesisers
Local oscillator signals for TX and RX up/down conversions
Frequency hopping capability on timeslot basis
Fan Module
DN70178382
Issue 4-0
11
Flexi EDGE BTS Dual TRX Module (EXxx) Description Dual TRX Module (EXxx) main blocks
Id:0900d8058063db59
In 2-way diversity case the signal comes from DTRX's other Rx main connector
and with 4-way diversity the signal comes from the diversity Rx connector.
PSU - power supply unit, BB - baseband, IF - interface, DP - double power, FHS
- frequency hopping system, PA - power amplifier
Figure 2 Dual TRX Module main blocks
Dual TRX Module
Fan Module
BB Module
BB
PSU (All voltages)
D
a
t
a
C
o
n
v
e
r
t
e
r
Power,
Data, IF
signals,
Control
signals
and
Clock
Fan Connector
T
X
2
C
h
a
i
n
D
i
v
R
X
2
M
a
i
n
R
X
2
R
X
F
F
S
D
i
v
R
X
1
M
a
i
n
R
X
1
RX FHS 1 & 2
28V
PSU
28V
PSU
TX FHS 1 & 2
Supports DP functionality
BUS
ERxA
PWR
(48 V)
DP
T
X
1
C
h
a
i
n
P
A
M
o
d
u
l
e
P
A
M
o
d
u
l
e
TxA RxA
RxA_
Div
RxB
RxB_
Div
TxB
TRX Module
DN70185184
12 DN70178382
Issue 4-0
Flexi EDGE BTS Dual TRX Module (EXxx) Description
Id:0900d8058063dbac
Dual TRX Module (EXxx) power requirements
4 Dual TRX Module (EXxx) power requirements
Maximum: maximum power consumption, 2 carriers ON all the time at Power Level 0
Nominal: expected (average) power consumption, 2 carriers ON all the time at Power
Level 0
Idle: no Power Amplifiers ON (for example, no active timeslots)
One PA in Use: expected (average) power consumption, 1 carrier ON all the time at
Power Level 0
Note that the power consumption of the Dual Duplexer Module or MHAs are not included
in the table even though they are fed through the Dual TRX Module.
Property Value
Nominal system voltage 48 V DC
Input voltage range 40.5 - 57 V DC
Table 1 Dual TRX Module (EXxx) input voltage range
EXTx/EXGx (800/900) EXDx (1800) EXPx (1900)
Maximum 325 W 365 W 385 W
Nominal 295 W 335 W 355 W
Idle 39 W (EXTA/EXGA)
45 W (EXTB/EXGB)
37 W (EXDA)
50 W (EXDB)
37 W (EXPA)
50 W (EXPB)
One PA in use 180 W 200 W 210 W
Table 2 Dual TRX Module (EXxx) power consumption
DN70178382
Issue 4-0
13
Flexi EDGE BTS Dual TRX Module (EXxx) Description Dual TRX Module (EXxx) interfaces
Id:0900d8058063dbb2
5 Dual TRX Module (EXxx) interfaces
Figure 3 Flexi EDGE Dual TRX Module (EXxx) front panel connectors and labels
DN70131596
Bus
ER_A
PWR
DP
TxA RxA
RxA
Div
RxB
Div
RxB
Caution,
Hot Surface
Electrostatical
sensitive device
Grounding
point
TxB
LED
Label name
on module
Description Connector
type
Cable type Interface(s) Signal
direction
(to/from
the
module)
BUS Ethernet (1000 Base-
T/100 Base-TX)
baseband processing
of end user, hopping,
synchronisation, and
O&M data
MDR 26
(female)
Bus cable, AWG30
Twinax, MDR 26
(male)
length: 1054/1554
mm (41.5/61.2 in.)
ESMA, ESEA To and
from the
module
ER_A Power and control
interface for the ERxA
MDR 36
(female)
ERxA cable, MDR
36 (male)
hard-wired with
other end fixed to
ER_A
length: 200 mm (7.9
in.)
ERxA To and
from the
module
PWR -48 VDC input power
with fuse protection
Multi-Beam
XL (female)
Power cable, 2 x
AWG12, Multi-Beam
XL (male)
length: 1188/2000
mm (46.8/78.7 in.)
ESMA, ESEA To and
from the
module
Table 3 Flexi EDGE Dual TRX Module (EXxx) front panel connectors, cable types and interfaces
14 DN70178382
Issue 4-0
Flexi EDGE BTS Dual TRX Module (EXxx) Description
Id:0900d8058063dbb2
Dual TRX Module (EXxx) interfaces
DP Synchronous combin-
ing of both transmit-
ters in the module to
generate one
GSM/EDGE carrier
capacity with
increased output
power
NOTE: Interface to
the EWxA (required
module with the DP
feature)
Molex Microfit
(male)
DP cable, 4 x
AWG24, Molex
Microfit (female)
length: 203 mm (8.0
in.)
EWxA To and
from the
module
RxA, RxB
(blue)
Receives a digitally
modulated
GSM/EDGE RF
carrier in accordance
with the appropriate
telecommunications
standard (Rx input)
QMA
(female)
RF cable, SemiFlex
50, QMA (male)
length:
172/275/1300 mm
(6.8/10.8/51.2 in.)
ERxA, ECxA To the
module
RxA Div , RxB
Div (blue)
Four-way uplink
receive diversity
(4UD)
NOTE: This connector
is also used in 2UD
configurations which
require splitting an
EXxx between cell
areas (for example,
cost optimized config-
urations, 1+3).
QMA
(female)
RF cable, SemiFlex
50, QMA (male)
length:
172/275/1300 mm
(6.8/10.8/51.2 in.)
ERxA, ECxA To the
module
TxA, TxB (red) Transmits a digitally
modulated
GSM/EDGE RF
carrier in accordance
with the appropriate
telecommunications
standard (Tx output).
QMA
(female)
RF cable, SemiFlex
50, QMA (male)
length:
172/275/1300 mm
(6.8/10.8/51.2 in.)
ERxA, EWxA,
ECxA
From the
module
Label name
on module
Description Connector
type
Cable type Interface(s) Signal
direction
(to/from
the
module)
Table 3 Flexi EDGE Dual TRX Module (EXxx) front panel connectors, cable types and interfaces (Cont.)
DN70178382
Issue 4-0
15
Flexi EDGE BTS Dual TRX Module (EXxx) Description Dual TRX Module (EXxx) dimensions and weight
Id:0900d8058063dbf3
6 Dual TRX Module (EXxx) dimensions and
weight
The dimensions of the Flexi EDGE Dual TRX Module are presented in the table below.
1)
Width of the casing without front covers/with front covers
2)
Depth of the casing without front covers/with front covers
Property Value
Width
1)
447/492 mm
(17.6/19.4 in.)
Height 90 mm
(3.5 in.)
Depth
2)
422/560 mm
(16.6/22.1 in.)
Weight 7.58 kg
(16.7 lbs)
Table 4 EXxx dimensions and weight
16 DN70178382
Issue 4-0
Flexi EDGE BTS Dual TRX Module (EXxx) Description
Id:0900d8058063de43
Dual TRX Module (EXxx) LED indications
7 Dual TRX Module (EXxx) LED indications
The Dual TRX Module (EXxx) has two tri-colour LEDs on the front panel to indicate the
operational status of the module and all fault conditions during operation.
Colour Explanation
Cycling colours BTS has requested highlighting for TRX module and
timer is still running.
Red, blinking 7606 alarm is active on one of the carriers or
7607 alarm is active on one or on both carriers.
7607 alarm on IDD TRX or DPTRX TRX object.
Red, stable TRX_OM SW is not running or
7606 alarm is active on both carriers.
7606 alarm on IDD TRX or DPTRX TRX object.
Yellow, blinking TRX_OM SW state is Clock sync or
one or both carriers are in TRX_OM SW state TRX con-
figuring, Wait for OMUSIG establishment or Wait for
system information.
Yellow, stable Both carriers are blocked from BTS or
both carriers have TRXSIG channel disconnected when
in TRX_OM SW state is supervisory.
IDD TRX or DPTRX object blocked/locked or IDD TRX or
DPTRX TRX object is Shutdown (but is still providing
power/control for DDU supporting other TRX's or are
powered due to malfunctioning e.g. power cycle in
ESEA) from BSC or
IDD TRX or DPTRX TRX object has TRXSIG channel
disconnected when the carrier state is supervisory.
Green, blinking Only one carrier is in the supervisory state and no 7606
or 7607 alarm is active and LAPD on TRXSIG is con-
nected for this carrier, or.
both carriers are in supervisory state but one carrier has
LAPD on TRXSIG channel disconnected.
Not applicable when the TRX module is configured for
IDD TRX or DPTRX TRX object.
Green, stable Both carriers are in TRX_OM SW state supervisory and
no 7607 or 7606 alarms are active.
IDD TRX or DPTRX TRX object is in supervisory state
and no 7606 / 7607 alarms are active and TRXSIG is
connected.
Table 5 Dual TRX Module LED indications
DN70178382
Issue 4-0
17
Flexi EDGE BTS Dual TRX Module (EXxx) Description Contents of the Dual TRX Module (EXxx) delivery
Id:0900d8058063de9c
8 Contents of the Dual TRX Module (EXxx)
delivery
Description Product code Quantity
EDGE Dual TRX Module (EXxx): 1
EDGE Dual TRX Module 800 MHz (EXTA)
EDGE Dual TRX Module 800 MHz (EXTB)
EDGE Dual TRX Module 900 MHz (EXGA)
EDGE Dual TRX Module 900 MHz (EXGB)
EDGE Dual TRX Module 1800 MHz (EXDA)
EDGE Dual TRX Module 1800 MHz (EXDB)
EDGE Dual TRX Module 1900 MHz (EXPA)
EDGE Dual TRX Module 1900 MHz (EXPB)
470214A
472043A
470215A
472044A
470216A
472045A
470217A
472046A
Dual TRX Module Cable Set: 083309A 1
Power cable 1188 mm (46.8 in.) 994940
1
Bus cable 1054 mm (41.5 in.) 994938
1
RF cable 172 mm (6.8 in.) 994931
4
M5 thumbscrews (preinstalled) 4
Table 6 Flexi EDGE Dual TRX Module (EXxx) delivery contents