GEA Chillers and Heat Pumps with HX-Factor

Energy-efficient and compact models


for inside and outside installation
Product Brochure

==~==

db^=e~=b~

Good climate with HX-Factor:


Reliable. Efficient. Sustainable.
The HX-Factor is our performance promise. It
stands for unique competence in heat exchangers (HX = HEAT EXCHANGE) and characterizes all its products and services. The many
advantages associated with the HX-Factor offer
you maximum benefit over the entire lifetime
of the systems.

Economy and ecology in harmony


The signs of the times are clear
Investors, systems builders, planners and architects no longer ask whether, but how
they can improve the sustainability trend of their plant and building engineering.
Buildings are unique objects. Position, size, construction quality and increasingly the building technology determine values and yields. The energetic state is considerably gaining
in significance, because buildings are responsible for about 40 percent of world energy
consumption and contribute to 21 percent of the world-wide greenhouse gas emissions.
The proportion of the energy costs in the "second rent" for users and residents is constantly
increasing.
You come across the air condi-

Where heating, cooling, cleaning, filtering, humidification and dehumidification of air is

tioning technology with HX-

required, GEA makes its contribution to progress. Customized climate-control and air treat-

Factor in all walks of life.

ment, with the maximum-possible reduction of energy consumption over the entire life
cycle of the facilities: this all pays out handsomely in euros and cents, in comfort, and in
work productivity. In highly sensitive areas, such as clinical and cleanroom applications,
our solutions reliably satisfy all international standards and achieve high rankings in the
demanding classification of the Eurovent Compliance Committee for Air Handling Units.
They furthermore set new standards for sustainability and perfect system integration in
modern sport arenas, factory buildings, airport facilities, and swimming pools, as well as
in offices, museums and hotels. Summarized with the concept "HX-Factor", this quality justifies our technological advantage. The HX-Factor is more than just technology. It is an attitude and creates value with a future: quality of life for residents and users. Protection of
energy resources and our climate. Security for investors and planners.

x2]

PR-2014-0100-GB Subject to modifications K0-06/2014

Technical quality
Whoever treats air must master it
The fact that our air treatment is neither seen nor heard, although one is agreeably aware
of it, and that in the meantime it avoids energy and wasteful costs, is due to our precision
air-treatment work in both hardware and software.
Can a building with large glazed areas be heated during spring and autumn on its north
side and cooled on its south side, with only one system and without having to switch on
the central heating? Does a plant in the pharmaceutical or electronic industry, for instance,
which heats, cools, humidifies and dehumidifies the air, also offer protection from dirt and
bacteria? Can investors and building owners calculate the life cycle costs of a central plant
air handling unit, determine the effect of energy-saving equipment on the operating cost
for this purpose, and thus select the optimal efficiency class right in the configuration stage
of the plant?

GEA stands for:


GEA has found answers to this and many other questions concerning air treatment and cli-

Customized air quality and a

mate control and has implemented them in solutions which reflect its experience gained

healthy, comfortable indoor cli-

in many and various successful applications. The core proposal consists of a broad spec-

mate with extremely quiet

trum of central and decentral air treatment plants, separators and filter plants up to complete clean room systems. The function, control, and design of such facilities can be

operation
Maximum energy efficiency

precisely customized according to the desired task, adapted to the design characteristics

and reduction in CO2 emis-

and infrastructure of specific buildings, and designed according to the calculation of oper-

sions

ating costs as well as the highest standards of energy efficiency and climate protection. Cutting-edge control technology from our own development permits individual control in
single rooms as well as central handling within a building management system.

Precise control and regulation,

centrally and decentrally


High adaptability to the most

diverse tasks and environments


Control units with access through interfaces to all leading systems of building automation,

Simple system integration

provide for the trouble-free integration of all equipment in the building management sys-

Durability and high availability

tem. The fact that planners and users can implement their own wishes at the design stage

at low maintenance cost

of the plant itself is proof of the precision work involved in the air-conditioning equipment.
You can see that the HX-Factor has many facets. Generations of cross-functional experience
play a role, as do our customized engineering, worldwide proximity to our customers, and
our well-proven innovative abilities. Every individual GEA employee contributes to quality
by adding positive characteristics to the HX-Factor.
By enthusiasm for a technology that shapes the lives of people in progressive ways.
By special diligence and precision. By commitment at all levels. This quality transfers oneto-one to our products and services. Thus you can personally experience the HX-Factor. It
assures you many diverse product benefits. It rewards your trust with reliable, efficient
and sustainable solutions. Therefore count on the HX-Factor!

PR-2014-0100-GB Subject to modifications K0-06/2014

x3]

GEA chiller
Variety for your comfort
Irrespective of whether your requirement is for indoor or outdoor
installation, air or water-cooled, there is a vast variety of equipment
with or without heat pump and an extensive spectrum of accessories
available to you within the capacity range of 4.9 - 2.749 KW.
Last but not least, GEA chillers are characterized by their efficiency and
high energy conservation potential, additionally underlined by the use
of high-quality components and environmentally-friendly refrigerants
R-410A and R-134a, which are used in most GEA chillers depending
upon the model. With GEA chillers and heat pumps with reversible circuit, you can provide energy not only for cooling, but also for heating.
And if you require a compressor/condensing unit or want a system
with external condenser, our program includes the correct unit for you
here as well. The choice is yours.

Legend
Explanation of the pictograms used in this document
Pictogram

x4]

Description

Pictogram

Description

Screw compressor

Plate Heat Exchanger

Scroll
compressor

Shell and tube heat exchanger

Inverter compressor

Master/slave operation is possible

Refrigerant R-134a

Direct evaporator

Refrigerant R -410A

BMS integration is possible

R -407C refrigerant

Plate Heat Exchanger

Unit with free cooling

Heating

Unit as low-noise model

Cooling

Unit as high-performance model

Outdoor installation

Unit as high-temperature model

Indoor installation

Unit as low-noise model with extended operating


limits

Eurovent certified

PR-2014-0100-GB Subject to modifications K0-06/2014

Contents
Our Products
Economy and ecology in harmony - HX-Factor

Explanation of the pictograms used in this document

GEA chiller and heat pumps for outdoor installation

GEA chiller and heat pump for indoor mounting

Chiller outdoor installation air-cooled

10

GSAC 0011 ... 0061 FD5 / FD1 4.9 kW to 15.4 kW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10


GAC(N,P) 016 064 FD1 20 kW to 75 kW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
GLAC 2015 2081 CD1/2 / .SL (.HE) 39 kW to 227 kW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
GLAC 4061 4121 CD2 / .SL (.HE) 159 kW to 352 kW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
GLAC 4131 ... 8321 CD2 / .SL (.HE) 354 kW to 885 kW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
GLAC 0751 1301 BA2 / .SL 145 kW to 266 kW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
GLAC 1532 2632 BA2 / .SL 277 kW to 516 kW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
GLAC 1542 2642 BA2 / .SL 277 kW to 516 kW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
GLAC 2150 4840 CA2 / .SL (.HE) 295 kW to 1818 kW . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
GLFC 0152 0612 BD2 / .SL 37 kW to 162 kW with free cooling . . . . . . . . . . . . . . . . . . . . . . 29
GLFC 0604 ... 1204 BD2 / .SL 153 kW to 326 kW with free cooling . . . . . . . . . . . . . . . . . . . . . 32
GLFC 2150 ... 2482 DA2 / .SL 286 kW to 1212 kW with free cooling . . . . . . . . . . . . . . . . . . . . 35

Compressor/condensing unit outdoor installation air-cooled

38

GLCU 2015 ... 4060 BC1/2 / .SL 40 kW to 171 kW. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38

Chiller indoor installation air-cooled

39

GSDC 0011 ... 0041 FD5 / FD1 4.9 kW to 15.4 kW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39


GLDC 0152 1204 BD2 37 kW to 312 kW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
GLRC 2015 4160 CD2 41 kW to 442 kW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
GLWC 0152 1204 BD2 43 kW to 371 kW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
GLWC 0401 1902 BA2 87 kW to 447 kW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
GLWC 1130 4960 CA2 / .HE 306 kW to 2416 kW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48

Heat pump outdoor installation air-cooled

50

GSAH 0011 ...0061 FD5 / FD1 5.7 kW to 16.8 kW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50


GAH(N,P) 016 064 FD1 20 kW to 75 kW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
GLAH 0152 0612 BD1 / .LT 42 kW to 174 kW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
GLAH 0524 1204 BD2 / .LT 147 kW to 359 kW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
GLAH 4131 ...8321 CD2 / .LT 373 kW to 902 kW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
GCH 100 250 CD4 / CD1 13 kW to 32 kW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58

Heat pump indoor mounting air-cooled

59

GSDH 0011 ...0061 FD5 / FD1 5.7 kW to 16.8 kW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59

Heat pump indoor installation water-cooled

60

GLWH 0152 1204 BD2 50 kW to 419 kW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60


GLWH 0401 1902 BA2 97 kW to 494 kW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
GLWH 1130 ...4960 CA2 339 kW to 2663 kW. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
GLWH 1130 ...4960 CA2.HT 345 kW to 2581 kW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66

Hydraulic module indoor and outdoor installation

68

GLHM#03# ... #25#-00 Buffer Volume 300 l to 2500 l . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70

Controls

69

Overview of accessories

70

First Service

74

PR-2014-0100-GB Subject to modifications K0-06/2014

x5]

GEA chiller and heat pumps for outdoor installation


Overview of capacity
Cooling/heating duty [kW]

10

20

40

60

80

100

150

200

300

400

GSAC 0011...0061 FD1/5


GAC(N,P) 016...064 FD1
GLAC 2015...2081 CD1/2
GLAC 4061 ...4121 CD2
Chiller
air cooled

GLAC 4131... 8
GLAC 0751...1301 BA2
GLAC 1532...2632 BA2

GLAC 1542...2642 BA2


GLAC 2150...4840

GLFC 0152...0612 BD2


Chiller
air cooled, with free cooling

GLFC 0604...1204 BD2

GLFC 2150...2482

GSAH 0011...0061 FD1/5


GAH(N,P) 016...064 FD1
Heat pump configuration
air/water

GLAH 0152...0612 BD1


GLAH 0524...1204 BD2

GLAH 4131 .

GCH 100...250 CD1/CD4


Compressor
condensing unit

GLCU 2015...2052 BC1


GLCU 4052...4060 BC2

Hydraulic module
external buffer tank module
x6]

GLHM-00

PR-2014-0100-GB Subject to modifications K0-06/2014

500

750

1000

2000

R410A

R 407C

R 134a

Screw compressor

Scroll
compressor

Hydraulic mod- Hydraulic module as standard ule as option

Pump module
as option

321 CD2

CA2

DA2

..8321 CD2

PR-2014-0100-GB Subject to modifications K0-06/2014

x7]

GEA chiller and heat pump for indoor installation


Overview of capacity

Cooling/heating duty [kW]

10

20

40

60

80

100

150

200

300

400

GSDC 0011...0061 FD1/5


Chiller
air cooled, for duct connection

GLDC 0152...0612 BD2


GLDC 0604...1204 BD2

Heat pump model


air/water

GSDH 0011...0061 FD1/5

GLRC 2015...2061 CD2


Chiller
without condenser
GLRC 4060...4160 CD2

GLWC 0152...0612 BD2


GLWC 0604...1204 BD2
Chiller,
water cooled

GLWC 0401 ... 1902 BA2


GLWC 1130 ... 49

GLWH 0152...0612 BD2


GLWH 0604...1204 BD2
Heat pump model
water/water

GLWH 0401...1902 BA2


GLWH 1130

Hydraulic module
external buffer tank module

x8]

GLHM-00

PR-2014-0100-GB Subject to modifications K0-06/2014

500

750

1000

2000

R410A

R 407C

R 134a

Screw compressor

Scroll
Hydraulic mod- Hydraulic mod- Pump module
compressor ule as standard ule as option
as option

0 CA2
GLWC 2450 ... 4960 CA2

...2420 CA2 (.HT)


GLWH 2450 ...4960 CA2 (.HT)

PR-2014-0100-GB Subject to modifications K0-06/2014

x9]

Chiller outside installation air-cooled


GSAC 0011 ... 0061 FD5 / FD1 4.9 kW to 15.4 kW

Equipment
Optimized packaged model with 1 scroll compressor
self-supporting sheet steel construction

- galvanized
- powder-coated
Standard pump module integrated

additionally fitted with safety valve, expansion tank, pressure


gauge, air vent and fill connection
Following pump heads for pipework provided on-site
Second pump to enlarge the delivery head

as option for model sizes 0041 ... 0061


Buffer tank to be mounted below the unit is available as an option
Cooling operation down to -10 C air inlet temperature

Can be delivered in two different versions:

Condensing pressure is used to regulate fan speed

GSAC 0011 ... 0041 FD5 with 230 V supply voltage

Autoadaptive microprocessor control

GSAC 0021 ... 0061 FD1 with 400 V supply voltage

Supply voltage

Refrigerant R-410a
Cooling capacity
ESEER

1~230 Volt (Series FD5)

3~400 Volt (Series FD1)

GSAC

0011

0021

0025

0031

0041

0021

0025

0031

0041

0051

0061

kW

4.9

5.6

6.9

8.6

11.0

5.6

7.0

8.7

11.4

13.2

15.4

3.1

3.4

3.3

3.3

3.2

3.4

3.4

3.3

3.3

3.3

3.5

Max. current consumption

17.6

17.6

20.6

24.6

28.6

7.1

7.6

9.6

11.6

13.4

16.6

Max. power consumption

kW

1.9

2.1

2.5

3.4

4.1

2.0

2.4

3.1

4.2

4.7

5.2

Scroll
compressor

Quantity

Refrigeration Circuits

Quantity

Capacity stages

Quantity

Delivery head of remaining pipework

kPa

59.0

57.0

54.0

54.0

43.0

57.0

54.0

54.0

40.0

33.0

30.0

Rated volume flow

m/h

0.8

1.0

1.2

1.5

1.9

1.0

1.2

1.5

2.0

2.3

2.7

Sound power level

dB(A)

65

66

66

66

69

66

66

66

69

69

69

Sound pressure level

dB(A)

37

38

38

38

41

38

38

38

41

41

41

Length

mm

900

900

900

900

900

900

900

900

900

900

900

Width

mm

370

370

370

370

370

370

370

370

370

370

420

Height

mm

640

640

940

940

1240

640

940

940

1240

1240

1390

Weight

kg

80

85

100

105

125

85

100

105

125

145

155

Performance data
Sound power level
Sound pressure level

x10]

At chilled water 12/7C and air intake temperature 35C


EUROVENT certified figure, requirement specified by Eurovent 8/1 and ISO 9614
Rectangular-shaped radiation 10 m distance reflection factor Q=2
For project-related sound data calculations - use the obligatory sound power level!

PR-2014-0100-GB Subject to modifications K0-06/2014

Chiller outdoor installation air-cooled


GAC(N,P) 016 064 FD1 20 kW to 75 kW

Equipment
Space-saving optimized version with 1 or 2 DC inverters

Scroll compressors
Cooling operation from -15 C to +43 C air inlet temperature
Microprocessor control
Automatic self-diagnostics
Integrated 24h real-time clock with indication of weekdays
Inverter-controlled condenser fans
Electronic pressure sensing HP/LP
Unit main switch
Electronic pressure sensor for high pressure and low pressure
Installed water filter
Shut-off valves for water inlet and outlet are supplied separately

Can be delivered in two different versions:

Flow switch mounted and cabled in the unit

GACN - without hydraulic unit.

Noise-reduced operation possible

GACP - with pump module, manometer, safety valve, expan-

Leading/following operation of several units with accessories

sion tank

GZSEQUENC.E18 is possible
Connection to the building management system with Modbus Pro-

tocol with accessory GZAMODBUS.E14 is possible


Additional controller functions, see page 69

Refrigerant R -410A
Cooling capacity

GAC_*

016

021

025

032

040

050

064

kW

20.0

25.0

30.0

37.5

50.0

60.0

75.0

ESEER

4.8

4.7

4.5

4.0

4.6

4.4

4.0

Max. current consumption

22.0

25.0

26.0

35.0

47.0

50.0

67.0

Max. power consumption

kW

7.4

9.2

12.7

18.2

19.3

27.3

39.3

Scroll
compressor

Quantity

Refrigeration Circuits

Quantity

Capacity stages

Quantity

Sound power level

dB(A)

78

78

78

80

81

81

83

Sound pressure level

dB(A)

46

46

46

48

49

49

51

Length

mm

1371

1371

1371

1684

2358

2358

2980

Width

mm

774

774

774

774

780

780

780

Height

mm

1684

1684

1684

1684

1684

1684

1684

*Weight GACN without pump

kg

267

320

320

401

577

577

738

*Weight GACP with pump

kg

282

235

335

415

610

610

771

Performance data
Sound power level
Sound pressure level

At evaporation temperature 7 C and air inlet temperature 35 C


Requirement specified by Eurovent 8/1 and ISO 9614
Rectangular-shaped radiation 10 m distance reflection factor Q=2
For project-related sound data calculations - use the obligatory sound power level!

PR-2014-0100-GB Subject to modifications K0-06/2014

x11]

Chiller outside installation air-cooled


GLAC 2015 2081 CD1/2 / .SL (.HE) 39 kW to 227 kW

Equipment
Standard configuration with 2 scroll compressors
Buffer tank and pump optional (hydraulics module GLHM)

In addition, with flow switch, regulating valve, safety valve, expansion vessel, venting and filler connection
Aluminium "Micro Channel" condenser with special corrosion pro-

tection coating (E-Coating)


Cooling operation down to -10 C ambient temperature
Autoadaptive microprocessor control
Controller type: HVAC Systems Step I/II
Unit main switch
Master/slave operation with GEA HVAC System unit series availa-

ble as an accessory item

Deliverable in three different versions:


GLAC 2015 2070 CD1/2 as standard unit

Connection to BMS via optional interface

GLAC 2015 2070 CD1/2.SL especially quiet version


GLAC 2015 2081 CD1/2.HE as highly efficient version

Refrigerant R -410A

GLAC

2015

2018

2020

2025

2026

2030

2035

2040

2045

2050

2055

2060

2070

Cooling capacity

kW

39.2

44.3

51.9

58.9

65.0

77.6

88.5

102.0

114.5

127.4

144.3

165.7

189.5

El. power consumption

kW

13.5

15.6

18.1

20.5

23.5

26.8

31.3

35.4

40.2

44.9

52.3

57.7

67.9

EER

2.9

2.8

2.9

2.9

2.8

2.9

2.8

2.9

2.9

2.8

2.8

2.9

2.8

ESEER

4.4

4.4

4.4

4.4

4.3

4.2

4.4

4.0

4.1

4.1

4.2

4.1

4.2

Cooling capacity

kW

39.0

44.0

51.6

58.6

64.7

77.3

88.0

101.4

113.8

126.8

143.5

164.9

188.6

El. power consumption

kW

13.7

15.9

18.4

20.8

23.8

27.1

31.9

35.9

40.8

45.6

53.0

58.5

68.8

2.8

2.8

2.8

2.8

2.7

2.9

2.8

2.8

2.8

2.8

2.7

2.8

2.7

Performance values
according to
EN14511:2011

EER
ESEER

4.2

4.2

4.2

4.2

4.2

4.1

4.2

3.9

4.0

4.0

4.0

3.9

4.0

Max. current conmp.

33.9

36.1

45.2

49.6

55.4

67.6

73.2

80.0

89.7

99.4

112.5

129.5

152.5

kW

18.8

21.0

24.6

27.4

29.8

35.5

40.8

48.6

53.7

58.8

67.2

77.6

91.8

Scroll compressor

Quantity

Refrigeration Circuits

Quantity

Capacity stages

Max. power consumption

Quantity

Sound power level

dB(A)

83

83

84

84

84

85

86

88

88

88

89

90

90

Sound pressure level

dB(A)

51

51

52

52

52

53

54

56

56

56

57

58

58

Length

mm

1755

1755

1755

2290

2290

2290

2290

2825

2825

2825

3360

3980

3980

Width

mm

1195

1195

1195

1195

1195

1195

1195

1195

1195

1195

1195

1195

1195

Height

mm

1885

1885

1885

1885

1885

1885

1885

2010

2010

2010

2010

2010

2010

kg

470

480

490

540

550

570

660

830

870

900

980

1130

1110

Weight
Performance data
Sound power level
Sound pressure level

x12]

At chilled water 12/7C and air intake temperature 35C


EUROVENT certified figure, requirement specified by Eurovent 8/1 and ISO 9614
Rectangular-shaped radiation 10 m distance reflection factor Q=2
For project-related sound data calculations - use the obligatory sound power level!

PR-2014-0100-GB Subject to modifications K0-06/2014

Chiller outside installation air-cooled


GLAC 2015 2081CD1/2.SL (.HE) 39 kW to 227 kW
Refrigerant R -410A

GLAC.SL

2015

2018

2020

2025

2026

2030

2035

2040

2045

2050

2055

2060

2070

Cooling capacity

kW

39.4

44.6

52.3

58.9

65.9

77.8

88.5

100.0

113.4

124.3

140.5

153.0

175.4

El. power consumption

kW

13.9

16.1

18.2

20.3

22.9

27.4

30.5

35.1

39.3

44.8

52.5

61.7

72.1

EER

2.8

2.8

2.9

2.9

2.9

2.8

2.9

2.9

2.9

2.8

2.7

2.5

2.4

ESEER

4.3

4.3

4.5

4.2

4.2

4.3

4.4

4.4

4.4

4.3

4.3

4.1

4.0

Cooling capacity

kW

39.2

44.3

52.0

58.6

65.5

77.4

87.9

99.4

112.8

123.7

139.8

152.3

174.6

El. power consumption

kW

14.1

16.3

18.5

20.6

23.2

27.8

31.1

35.7

39.9

45.4

53.2

62.4

72.8

2.8

2.7

2.8

2.9

2.8

2.8

2.8

2.8

2.8

2.7

2.6

2.4

2.4

Performance values
according to
EN14511:2011

EER
ESEER

4.1

4.1

4.3

4.0

4.1

4.1

4.1

4.2

4.2

4.2

4.1

4.0

3.8

Max. current conmpt.

34.4

36.6

44.6

53.0

58.8

68.8

71.1

76.7

89.7

103.3

116.4

129.5

152.5

Max. power consumption

kW

19.0

21.2

24.6

28.8

31.2

36.4

41.6

46.9

52.1

58.4

66.8

75.2

91.8

Scroll
compressor

Quantity

Refrigeration Circuits

Quantity

Capacity stages

Quantity

Sound power level

dB(A)

76

77

77

78

78

78

79

80

81

81

82

82

83

Sound pressure level

dB(A)

44

45

45

46

46

46

47

48

49

49

50

50

51

kg

540

550

560

670

680

680

860

960

1070

1080

1110

1180

1150

2071

2081

Weight

Refrigerant R 410A

GLAC.HE 2015

2018

2020

2025

2026

2030

2035

2040

2045

2050

2056

2061

Cooling capacity

kW

41.7

47.4

55.0

62.5

69.6

85.1

96.6

108.0 121.9 137.8 160.4 178.4 201.2 227.1

El. power consumption

kW

12.9

14.5

16.7

19.3

21.8

26.5

30.2

33.6

38.3

42.6

48.9

55.4

63.5

70.5

EER

3.2

3.3

3.3

3.2

3.2

3.2

3.2

3.2

3.2

3.2

3.3

3.2

3.2

3.2

ESEER

4.6

4.7

4.5

4.5

4.5

4.3

4.4

4.4

4.5

4.3

4.3

4.3

4.4

4.2

Cooling capacity

kW

41.4

47.1

54.7

62.1

69.2

84.6

95.9

107.3 121.2 137.0 159.4 177.5 200.2 225.7

El. power consumption

kW

13.1

14.8

17.1

19.6

22.2

26.9

30.9

34.3

39.0

43.4

49.8

56.4

64.5

71.9

EER

3.2

3.2

3.2

3.2

3.1

3.1

3.1

3.1

3.1

3.2

3.2

3.2

3.1

3.1

ESEER

4.3

4.4

4.2

4.3

4.3

4.1

4.1

4.2

4.3

4.1

4.1

4.1

4.2

4.0

Max. current consumption

35.0

37.2

47.4

51.8

57.6

68.8

74.4

79.7

89.4

103.3 121.1 134.2 148.6 167.1

Max. power consumption

kW

19.0

21.2

25.1

27.9

30.3

38.0

43.3

48.3

53.4

60.8

71.2

79.6

88.5

99.4

Quantity

Refrigeration Circuits Quantity

Capacity stages

Quantity

Sound power level

dB(A)

84

84

85

85

86

88

88

90

90

90

91

91

92

93

Sound pressure level

dB(A)

52

52

53

53

54

56

56

58

58

58

59

59

60

61

kg

480

540

550

560

570

680

830

960

1000

1080

1510

1550

1570

1810

Performance values according to


EN14511:2011

Scroll
compressor

Weight
Performance data
Sound power level
Sound pressure level

At chilled water 12/7C and air intake temperature 35C


EUROVENT certified figure, requirement specified by Eurovent 8/1 and ISO 9614
Rectangular-shaped radiation 10 m distance reflection factor Q=2
For project-related sound data calculations - use the obligatory sound power level!
Dimensions on previous page.

PR-2014-0100-GB Subject to modifications K0-06/2014

x13]

Chiller outside installation air-cooled


GLAC 4061 4121 CD2 / .SL (.HE) 159 kW to 352 kW

Equipment
Standard configuration with 4 scroll compressors
Buffer tank and pump are optional (hydraulic module GLHM) addi-

tionally fitted with a regulating valve, safety valve, expansion tank,


air vent and fill connection
Aluminium "Micro Channel" condenser
Cooling operation down to -15 C ambient temperature possible

(accessories)
Autoadaptive microprocessor control
Controller type: HVAC Systems Step II
Unit main switch
Master/slave operation with GEA HVAC System unit series availa-

ble as an accessory item


Connection to BMS via optional interface

Deliverable in three different versions:


GLAC 4061 4121 CD2 as standard unit
GLAC 4061 4121 CD2.SL as especially quiet version
GLAC 4061 4121 CD2.HE as highly efficient version

GLAC

4061

4071

4081

4091

4101

4111

4121

Cooling capacity

kW

164.7

194.1

217.8

248.2

289.2

308.4

326.7

El. power consumption

kW

58.3

66.7

78.9

88.6

99.0

108.4

118.2

EER

2.8

2.9

2.8

2.8

2.9

2.8

2.8

ESEER

4.1

4.4

4.3

4.4

4.3

4.3

4.2

Cooling capacity

kW

163.9

193.2

216.8

247.1

287.9

307.2

325.2

El. power consumption

kW

59.1

67.6

79.9

89.7

100.3

109.7

119.6

EER

2.8

2.9

2.7

2.8

2.9

2.8

2.7

ESEER

3.9

4.2

4.1

4.2

4.0

4.1

4.0

Max. current consumption

133.0

157.0

176.0

198.0

229.0

243.0

256.0

Max. power consumption

Refrigerant R -410A

Performance values
according to
EN14511:2011

kW

77.0

90.0

103.0

116.0

132.0

143.0

153.0

Scroll
compressor

Quantity

Refrigeration Circuits

Quantity

Capacity stages

Quantity

Sound power level

dB(A)

92

92

93

94

95

95

95

Sound pressure level

dB(A)

60

60

61

62

63

63

63

Length

mm

3160

3160

3160

3160

4335

4335

4335

Width

mm

2250

2250

2250

2250

2250

2250

2250

Height

mm

2170

2170

2170

2170

2170

2170

2170

Weight

kg

1510

1680

1690

1830

2250

2300

2330

Performance data
Sound power level
Sound pressure level

x14]

At chilled water 12/7C and air intake temperature 35C


EUROVENT certified figure, requirement specified by Eurovent 8/1 and ISO 9614
Rectangular-shaped radiation 10 m distance reflection factor Q=2
For project-related sound data calculations - use the obligatory sound power level!

PR-2014-0100-GB Subject to modifications K0-06/2014

Chiller outside installation air-cooled


GLAC 4061 4121 CD2.SL (.HE) 159 kW to 352 kW
Refrigerant R 410A

GLAC.SL

4061

4071

4081

4091

4101

4111

4121

Cooling capacity

kW

159.0

179.9

214.3

241.3

264.0

296.1

312.2

El. power consumption

kW

56.3

70.7

77.8

89.4

103.7

109.1

119.6

EER

2.8

2.5

2.8

2.7

2.6

2.7

2.6

ESEER

4.3

4.4

4.4

4.4

4.3

4.3

4.3

Cooling capacity

kW

158.3

179.2

213.4

240.3

263.0

294.9

311.0

El. power consumption

kW

57.0

71.5

78.7

90.4

104.7

110.2

120.9

EER

2.8

2.5

2.7

2.7

2.5

2.7

2.6

ESEER

4.1

4.2

4.2

4.2

4.1

4.2

4.1

Max. current consumption

133.0

157.0

184.0

207.0

229.0

251.0

264.0

Max. power
consumption

kW

74.0

87.0

102.0

115.0

127.0

140.0

151.0

Scroll
compressor

Quantity

Refrigeration Circuits

Quantity

Capacity stages

Performance values according to


EN14511:2011

Quantity

Sound power level

dB(A)

82

83

83

84

84

86

86

Sound pressure level

dB(A)

50

51

51

52

52

53

53

kg

1550

1730

2030

2170

2300

2700

2730

Refrigerant R 410A

GLAC.HE

4061

4071

4081

4091

4101

4111

4121

Cooling capacity

kW

174.1

205.2

235.4

266.4

301.9

330.0

352.0

El. power consumption

kW

54.4

65.0

72.9

84.1

95.8

102.8

111.1

EER

3.2

3.2

3.2

3.2

3.2

3.2

3.2

ESEER

4.3

4.3

4.5

4.5

4.4

4.4

4.4

Cooling capacity

kW

173.6

204.5

234.2

265.2

300.9

328.8

350.6

El. power consumption

kW

54.9

65.8

74.1

85.3

96.7

104.0

112.5

EER

3.2

3.1

3.2

3.1

3.1

3.2

3.1

ESEER

4.2

4.1

4.2

4.2

4.3

4.2

4.2

Max. current consum

133.0

165.0

184.0

207.0

229.0

251.0

264.0

Max. power consum.

kW

77.0

94.0

107.0

120.0

132.0

147.0

157.0

Quantity

Refrigeration Circuits Quantity

Capacity stages

Quantity

Sound power level

dB(A)

92

93

94

95

95

96

97

Sound pressure level

dB(A)

60

61

62

63

63

64

65

kg

1700

2150

2160

2290

2550

2930

2950

Weight

Performance values according to


EN14511:2011

Scroll
compressor

Weight
Performance data
Sound power level
Sound pressure level

At chilled water 12/7C and air intake temperature 35C


EUROVENT certified figure, requirement specified by Eurovent 8/1 and ISO 9614
Rectangular-shaped radiation 10 m distance reflection factor Q=2
For project-related sound data calculations - use the obligatory sound power level!
Dimensions on previous page.

PR-2014-0100-GB Subject to modifications K0-06/2014

x15]

Chiller outside installation air-cooled


GLAC 4131 ... 8321 CD2 / .SL (.HE) 354 kW to 885 kW

Equipment
High-efficiency optimized version with 4, 6 or 8 scroll compressors
Buffer tank and pump are optional (hydraulic module GLHM) addi-

tionally fitted with a safety valve, expansion tank, air vent and fill
connection
Aluminium "Micro Channel" condenser
Cooling operation down to -15 C ambient temperature
Autoadaptive microprocessor control
Controller type: HVAC Systems Step II
Unit main switch
Configuration with an electronic expansion valve EEV
Master/slave operation with GEA HVAC System unit series availa-

Deliverable in three different versions:

ble as an accessory item


Connection to BMS via optional interface

GLAC 4131 8321 CD2 as standard unit


GLAC 4131 8321 CD2.SL as especially quiet version
GLAC 4131 8321 CD2.HE as highly efficient version

Refrigerant R -410A

GLAC

4131

4141

4161

5171

6181

5201

6211

6231

6241

8241

8261

8281

8301

8321

Cooling capacity

kW

354.3 378.8 413.4 458.3 501.3 525.6 569.4 603.7 634.9 665.3 707.9 759.4 793.5 826.6

El. power consumption

kW

124.4 130.2 147.8 160.4 171.9 183.9 195.4 214.1 218.6 233.7 248.8 260.5 279.1 295.7

EER

2.9

2.9

2.8

2.9

2.9

2.9

2.9

2.8

2.9

2.9

2.9

2.9

2.8

2.8

ESEER

4.2

4.2

4.0

4.2

4.2

4.1

4.2

4.1

4.1

4.1

4.2

4.3

4.2

4.1

Performance values
according to
EN14511:2011
Cooling capacity

kW

352.8 377.5 411.7 456.5 499.1 524.0 567.4 601.7 632.5 662.9 705.0 756.9 790.8 823.5

El. power consumption

kW

126.0 131.5 149.6 162.1 174.1 185.5 197.4 216.2 221.0 236.1 251.6 262.9 281.9 298.7

EER

2.8

2.9

2.8

2.8

2.9

2.8

2.9

2.8

2.9

2.8

2.8

2.9

2.8

2.8

ESEER

4.0

4.1

3.9

4.0

4.0

3.9

4.0

4.0

3.9

4.0

4.0

4.1

4.0

3.9

Max. current consum.

273.0 288.0 317.0 351.0 384.0 398.0 432.0 461.0 480.0 534.0 572.0 609.0 630.0 650.0

Max. power consum.

kW

166.0 177.0 198.0 214.0 231.0 249.0 265.0 286.0 299.0 329.0 348.0 367.0 381.0 395.0

Scroll compressor

Quantity

Refrigeration Circuits

Quantity

Capacity stages

Quantity

Sound power level

dB(A)

96

96

96

96

97

97

97

97

98

98

98

99

99

99

Sound pressure level

dB(A)

64

64

64

64

65

65

64

64

65

65

65

66

66

66

Length

mm

3905

3905

5080

5080

5080

5080

6255

6255

6255

7430

7430

7430

7430

7430

Width

mm

2260

2260

2260

2260

2260

2260

2260

2260

2260

2260

2260

2260

2260

2260

Height

mm

2450

2450

2450

2450

2450

2450

2450

2450

2450

2450

2450

2450

2450

2450

Weight

kg

2730

2770

2800

3400

3650

3690

4200

4220

4350

5260

5300

5370

5400

5430

Performance data
Sound power level
Sound pressure level

x16]

At chilled water 12/7C and air intake temperature 35C


EUROVENT certified figure, requirement specified by Eurovent 8/1 and ISO 9614
Rectangular-shaped radiation 10 m distance reflection factor Q=2
For project-related sound data calculations - use the obligatory sound power level!

PR-2014-0100-GB Subject to modifications K0-06/2014

Chiller outside installation air-cooled


GLAC 4131 ... 8321 CD2.SL (.HE) 354 kW to 885 kW
Refrigerant R -410A

GLAC.SL

4131

4141

4161

5171

6181

5201

6211

6231

6241

8241

8261

8281

8301

8321

Cooling capacity

kW

333.6 358.1 397.4 431.5 465.0 497.7 532.3 579.3 595.9 615.9 666.4 717.7 757.8 794.6

El. power consumption

kW

129.2 137.3 153.1 168.1 182.7 191.6 206.0 220.0 229.7 244.6 258.3 274.8 288.4 306.2

EER

2.6

2.6

2.6

2.6

2.6

2.6

2.6

2.6

2.6

2.5

2.6

2.6

2.6

2.6

ESEER

4.3

4.3

4.2

4.3

4.4

4.3

4.4

4.4

4.3

4.3

4.4

4.4

4.4

4.3

Performance values
as of EN14511:2011
Cooling capacity

kW

332.2 356.9 395.9 430.0 463.2 496.2 530.6 577.5 593.9 613.9 664.0 715.6 755.4 791.8

El. power consumption

kW

130.5 138.5 154.7 169.6 184.5 193.0 207.7 221.9 231.7 246.6 260.7 276.9 290.8 309.0

EER

2.6

2.6

2.6

2.5

2.5

2.6

2.6

2.6

2.6

2.5

2.6

2.6

2.6

2.6

ESEER

4.1

4.2

4.1

4.2

4.1

4.1

4.2

4.2

4.2

4.2

4.2

4.2

4.2

4.1

Max. current consumption

266.0 283.0 312.0 344.0 375.0 390.0 422.0 453.0 468.0 524.0 561.0 598.0 619.0 640.0

kW

162.0 174.0 196.0 211.0 227.0 245.0 260.0 283.0 293.0 324.0 343.0 362.0 376.0 390.0

Max. power consumption

Scroll
compressor

Quantity

Refrigeration Circuits

Quantity

Capacity stages

Quantity

Sound power level

dB(A)

86

86

86

87

87

87

87

88

88

88

89

90

90

90

Sound pressure level

dB(A)

53

53

53

54

54

54

54

55

55

55

56

57

57

57

kg

3060

3160

3200

3900

4110

4190

4640

4730

4790

5410

5810

6160

6200

6250

Refrigerant R -410A GLAC.HE

4131

4141

4161

5171

6181

5201

6211

6231

6241

8241

8261

8281

8301

8321

Cooling capacity

kW

370.5 391.4 438.4 481.1 517.5 549.2 591.4 632.7 657.3 701.5 740.0 784.6 830.6 884.7

El. power consumption

kW

119.6 125.1 141.5 154.0 166.3 177.0 189.4 204.0 212.3 225.3 239.0 250.4 266.5 283.0

Weight

EER

3.1

3.1

3.1

3.1

3.1

3.1

3.1

3.1

3.1

3.1

3.1

3.1

3.1

3.1

ESEER

4.5

4.5

4.4

4.5

4.5

4.4

4.5

4.5

4.4

4.4

4.5

4.5

4.5

4.5

Performance values
as of EN14511:2011
Cooling capacity

kW

368.7 389.9 436.4 479.1 515.1 547.3 589.2 630.4 654.7 698.7 736.8 782.0 827.5 881.1

El. power consumption

kW

121.3 126.6 143.6 155.9 168.7 178.8 191.6 206.3 214.8 228.1 242.2 253.0 269.6 286.6

EER

3.0

3.1

3.0

3.1

3.1

3.1

3.1

3.1

3.1

3.1

3.0

3.1

3.1

3.1

ESEER

4.2

4.3

4.2

4.3

4.2

4.2

4.3

4.3

4.2

4.2

4.2

4.3

4.3

4.2

Max. current consumption

281.0 295.0 325.0 358.0 391.0 406.0 439.0 473.0 487.0 534.0 579.0 624.0 645.0 666.0

kW

170.0 181.0 202.0 218.0 235.0 253.0 269.0 292.0 303.0 329.0 352.0 375.0 389.0 403.0

Max. power consumption

Scroll
compressor

Quantity

Refrigeration Circuits

Quantity

Capacity stages

Quantity

Sound power level

dB(A)

97

97

97

97

98

98

98

99

99

99

99

100

100

100

Sound pressure level

dB(A)

65

65

65

64

65

65

65

66

66

66

66

67

67

67

kg

3060

3100

3130

3800

4050

4090

4540

4630

4690

5930

5970

6040

6070

6110

Weight
Performance data
Sound power level
Sound pressure level

At chilled water 12/7C and air intake temperature 35C


EUROVENT certified figure, requirement specified by Eurovent 8/1 and ISO 9614
Rectangular-shaped radiation 10 m distance reflection factor Q=2
For project-related sound data calculations - use the obligatory sound power level!
Dimensions on previous page.

PR-2014-0100-GB Subject to modifications K0-06/2014

x17]

Chiller outside installation air-cooled


GLAC 0751 1301 BA2 / .SL 145 kW to 266 kW

Equipment
Standard model with 1 screw compressor
Buffer tank and pump are optional (hydraulic module GLHM) addi-

tionally fitted with a regulating valve, safety valve, expansion tank,


air vent and fill connection
Cooling operation down to -15 C ambient temperature
With separately enclosed water filter
Autoadaptive microprocessor control
Controller type: HVAC Systems Step III
Unit main switch
Master/slave operation with GEA HVAC System unit series availa-

ble as an accessory item

Can be delivered in two different versions:

Connection to BMS via optional interface

GLAC 0751 1301 BA2 als Standardgert


GLAC 0751 1301 BA2.SL in especially quiet version

Refrigerant R-134a

GLAC

0751

0851

0951

0961

1021

1301

Cooling capacity

kW

144.5

162.5

182.4

201.3

234.3

266.1

El. power consumption

kW

51.5

60.9

68.7

75.1

85.4

93.5

EER

2.8

2.7

2.7

2.7

2.8

2.9

ESEER

3.5

3.4

3.5

3.6

3.5

3.5

Cooling capacity

kW

144.0

161.9

181.8

200.7

233.5

265.3

El. power consumption

kW

52.1

61.5

69.3

75.7

86.1

94.3

2.8

2.6

2.6

2.7

2.7

2.8

Performance values as
of EN14511:2011

EER
ESEER

3.4

3.4

3.5

3.6

3.4

3.5

Max. current consumption

117.0

127.0

144.0

144.0

154.0

201.0

Max. power consumption

kW

70.1

76.0

87.9

87.9

94.1

121.0

Screw compressor

Quantity

Refrigeration Circuits

Quantity

Minimum partial load level

50

50

50

50

50

50

Sound power level

dB(A)

94

94

94

94

96

96

Sound pressure level

dB(A)

62

62

62

62

64

64

Length

mm

3110

3110

3110

3110

4610

4610

Width

mm

2222

2222

2222

2222

2222

2222

Height

mm

2150

2150

2150

2150

2150

2150

Weight

kg

1680

1710

1780

1860

2590

2720

Performance data
Sound power level
Sound pressure level

x18]

At chilled water 12/7C and air intake temperature 35C


EUROVENT certified figure, requirement specified by Eurovent 8/1 and ISO 9614
Rectangular-shaped radiation 10 m distance reflection factor Q=2
For project-related sound data calculations - use the obligatory sound power level!

PR-2014-0100-GB Subject to modifications K0-06/2014

Chiller outside installation air-cooled


GLAC 0751 1301 BA2 / .SL 145 kW to 266 kW

Refrigerant R-134a

GLAC.SL

0751

0851

0951

0961

1021

1301

Cooling capacity

kW

134.3

150.9

165.8

197.4

223.1

238.3

El. power consumption

kW

53.3

62.7

73.5

76.2

90.3

101.5

EER

2.5

2.4

2.3

2.6

2.5

2.4

ESEER

3.5

3.4

3.4

3.7

3.6

3.3

Cooling capacity

kW

133.8

150.4

165.3

196.8

222.4

237.7

El. power consumption

kW

53.8

63.2

74.0

76.8

91.0

102.1

2.5

2.4

2.2

2.6

2.4

2.3

Performance values as
of EN14511:2011

EER
ESEER

3.5

3.3

3.3

3.6

3.5

3.3

Max. current consumption

112.0

122.0

139.0

143.0

148.0

195.0

Max. power consumption

kW

67.7

73.6

85.5

87.2

90.5

117.0

Screw compressor

Quantity

Refrigeration Circuits

Quantity

Capacity stages

Quantity

50

50

50

50

50

50

Sound power level

dB(A)

84

84

84

84

86

86

Sound pressure level

dB(A)

52

52

52

52

54

54

Length

mm

3110

3110

3110

4110

4610

4610

Width

mm

2222

2222

2222

2222

2222

2222

Height

mm

2150

2150

2150

2150

2150

2150

Weight

kg

1680

1770

1840

1980

2670

2720

Performance data
Sound power level
Sound pressure level

At chilled water 12/7C and air intake temperature 35C


EUROVENT certified figure, requirement specified by Eurovent 8/1 and ISO 9614
Rectangular-shaped radiation 10 m distance reflection factor Q=2
For project-related sound data calculations - use the obligatory sound power level!

PR-2014-0100-GB Subject to modifications K0-06/2014

x19]

Chiller outside installation air-cooled


GLAC 1532 2632 BA2 / .SL 277 kW to 516 kW

Equipment
Standard configuration with 2 screw compressors
Standard hydraulics module GLHM with integrated buffer tank and

pump
Pumps with larger delivery head are available
Following pump heads for remaining pipework provided on-site
Cooling operation down to -15 C ambient temperature
With separately enclosed water filter
Autoadaptive microprocessor control
Controller type: HVAC Systems Step III
Unit main switch
Master/slave operation with GEA HVAC System unit series availa-

ble as an accessory item

Can be delivered in two different versions:


GLAC 1532 2632 BA2 als Standardgert

Connection to BMS via optional interface

GLAC 1532 2632 BA2.SL in especially quiet version

Refrigerant R-134a

GLAC

1532

1732

1932

1952

2432

2632

Cooling capacity

kW

276.9

328.9

366.3

398.2

466.1

515.9

El. power consumption

kW

103.8

121.4

138.9

154.3

178.6

193.0

EER

2.7

2.7

2.6

2.6

2.6

2.7

ESEER

3.6

3.6

3.6

3.6

3.6

3.5

Cooling capacity

kW

275.9

327.6

364.8

396.5

463.9

513.3

El. power consumption

kW

104.8

122.7

140.4

155.9

180.9

195.5

EER

2.6

2.7

2.6

2.5

2.6

2.6

ESEER

3.6

3.5

3.5

3.8

3.5

3.4

Max. current consumption

233.0

259.0

295.0

295.0

371.0

413.0

Performance values as
of EN14511:2011

Max. power consumption

kW

140.0

156.0

181.0

181.0

225.0

249.0

Screw compressor

Quantity

Refrigeration Circuits

Quantity

Minimum partial load level

Quantity

25

25

25

25

25

25

Sound power level

dB(A)

97

97

97

97

99

99

Sound pressure level

dB(A)

65

65

65

65

67

67

Length

mm

4610

4610

4610

4610

5610

5610

Width

mm

2222

2222

2222

2222

2222

2222

Height

mm

2150

2420

2420

2420

2430

2430

Weight

kg

3130

3340

3490

3530

4590

4820

Performance data
Sound power level
Sound pressure level

x20]

At chilled water 12/7C and air intake temperature 35C


EUROVENT certified figure, requirement specified by Eurovent 8/1 and ISO 9614
Rectangular-shaped radiation 10 m distance reflection factor Q=2
For project-related sound data calculations - use the obligatory sound power level!

PR-2014-0100-GB Subject to modifications K0-06/2014

Chiller outside installation air-cooled


GLAC 1532 2632 BA2 / .SL 277 kW to 516 kW

Refrigerant R-134a

GLAC.SL

1532

1732

1932

1952

2432

2632

Cooling capacity

kW

252.3

295.6

333.5

376.6

442.5

484.3

El. power consumption

kW

111.5

128.0

148.8

164.4

183.4

199.5

EER

2.3

2.3

2.2

2.3

2.4

2.4

ESEER

3.5

3.5

3.5

3.6

3.7

3.5

Cooling capacity

kW

251.4

294.6

332.4

375.2

440.5

482.1

El. power consumption

kW

112.4

129.0

150.0

165.8

185.4

201.7

2.2

2.3

2.2

2.3

2.4

2.4

Performance values according to EN14511:2011

EER
ESEER

3.4

3.4

3.4

3.3

3.6

3.4

Max. current consumption

229.0

264.0

305.0

309.0

383.0

421.0

Max. power consumption

kW

138.0

154.0

180.0

182.0

222.0

244.0

Screw compressor

Quantity

Refrigeration Circuits

Quantity

Minimum partial load level

25

25

25

25

25

25

Sound power level

dB(A)

86

87

87

87

89

89

Sound pressure level

dB(A)

54

55

55

55

57

57

Length

mm

4610

4610

5610

5610

6610

6610

Width

mm

2222

2222

2222

2222

2222

2222

Height

mm

2150

2420

2430

2430

2430

2430

Weight

kg

3220

3450

3640

3840

5180

5450

Performance data
Sound power level
Sound pressure level

At chilled water 12/7C and air intake temperature 35C


EUROVENT certified figure, requirement specified by Eurovent 8/1 and ISO 9614
Rectangular-shaped radiation 10 m distance reflection factor Q=2
For project-related sound data calculations - use the obligatory sound power level!

PR-2014-0100-GB Subject to modifications K0-06/2014

x21]

Chiller outside installation air-cooled


GLAC 1542 2642 BA2 / .SL 277 kW to 516 kW

Equipment
Standard configuration with 2 screw compressors
Cooling operation down to -15 C ambient temperature
Autoadaptive microprocessor control
Controller type: HVAC Systems Step III
Unit main switch
Master/slave operation with GEA HVAC System unit series availa-

ble as an accessory item


Connection to BMS via optional interface

Can be delivered in two different versions:


GLAC 1542 2642 BA2 als Standardgert
GLAC 1542 2642 BA2.SL in especially quiet version

Refrigerant R-134a

GLAC

1542

1742

1942

1962

2442

2642

Cooling capacity

kW

276.9

328.9

366.3

398.2

466.1

515.9

El. power consumption

kW

103.8

121.4

138.9

154.3

178.6

193.0

EER

2.7

2.7

2.6

2.6

2.6

2.7

ESEER

3.6

3.6

3.6

3.6

3.6

3.5

Cooling capacity

kW

275.9

327.3

364.8

397.1

464.8

514.1

El. power consumption

kW

104.8

122.9

140.3

155.4

179.9

194.7

2.6

2.7

2.6

2.6

2.6

2.6

Performance values
according to
EN14511:2011

EER
ESEER

3.5

3.4

3.4

3.5

3.5

3.4

Max. current consumption

227.0

253.0

287.0

287.0

360.0

398.0

Max. power consumption

kW

137.0

153.0

177.0

177.0

219.0

241.0

Screw compressor

Quantity

Refrigeration Circuits

Quantity

Minimum partial load level

25

25

25

25

25

25

Sound power level

dB(A)

97

99

97

97

99

99

Sound pressure level

dB(A)

65

67

65

65

67

67

Length

mm

4610

4610

4610

4610

5610

5610

Width

mm

2222

2222

2222

2222

2222

2222

Height

mm

2150

2420

2420

2420

2430

2430

Weight

kg

3490

3680

3810

4100

5140

5340

Performance data
Sound power level
Sound pressure level

x22]

At chilled water 12/7C and air intake temperature 35C


EUROVENT certified figure, requirement specified by Eurovent 8/1 and ISO 9614
Rectangular-shaped radiation 10 m distance reflection factor Q=2
For project-related sound data calculations - use the obligatory sound power level!

PR-2014-0100-GB Subject to modifications K0-06/2014

Chiller outside installation air-cooled


GLAC 1542 2642 BA2 / .SL 277 kW to 516 kW

Refrigerant R-134a

GLAC.SL

1542

1742

1942

1962

2442

2642

Cooling capacity

kW

252.3

295.6

333.5

376.6

442.5

484.3

El. power consumption

kW

111.5

128.0

148.8

164.4

183.4

199.5

EER

2.3

2.3

2.2

2.3

2.4

2.4

ESEER

3.5

3.5

3.5

3.6

3.7

3.5

Cooling capacity

kW

251.4

294.5

332.4

375.6

441.4

482.8

El. power consumption

kW

112.3

129.1

149.9

165.3

184.5

201.0

2.2

2.3

2.2

2.3

2.4

2.4

Performance values according to EN14511:2011

EER
ESEER

3.4

3.4

3.4

3.6

3.6

3.4

Max. current consumption

221.0

253.0

294.0

294.0

368.0

406.0

Max. power consumption

kW

134.0

148.0

174.0

174.0

214.0

236.0

Screw compressor

Quantity

Refrigeration Circuits

Quantity

Minimum partial load level

25

25

25

25

25

25

Sound power level

dB(A)

86.0

87.0

87.0

87.0

89.0

89.0

Sound pressure level

dB(A)

54.3

55.1

55.0

55.0

56.8

56.8

Length

mm

4610

4610

5610

5610

6610

6610

Width

mm

2222

2222

2222

2222

2222

2222

Height

mm

2150

2420

2430

2430

2430

2430

Weight

kg

3580

3790

3960

4410

5730

5970

Performance data
Sound power level
Sound pressure level

At chilled water 12/7C and air intake temperature 35C


EUROVENT certified figure, requirement specified by Eurovent 8/1 and ISO 9614
Rectangular-shaped radiation 10 m distance reflection factor Q=2
For project-related sound data calculations - use the obligatory sound power level!

PR-2014-0100-GB Subject to modifications K0-06/2014

x23]

Chiller outside installation air-cooled


GLAC 2150 4840 CA2 / .SL (.HE) 295 kW to 1818 kW

Equipment
High-efficiency optimized version with 2, 3 or 4 screw compressors
Cooling operation down to -18 C ambient temperature possible

(accessories)
Autoadaptive microprocessor control
Controller type: HVAC Systems Step III
Unit main switch
Configuration with an electronic expansion valve EEV
Master/slave operation with GEA HVAC System unit series availa-

ble as an accessory item


Connection to BMS via optional interface

Deliverable in three different versions:


GLAC 2150 4840 CA2 as standard unit
GLAC 2150 4840 CA2.SL in especially quiet version
GLAC 2150 3660 CA2.HE as highly efficient version

Refrigerant R-134a

GLAC

2150

2170

2190

2192

2220

2265

2270

2272

2315

Cooling capacity

kW

308.0

342.8

384.8

434.0

494.8

562.8

599.0

665.7

735.5

El. power consumption

kW

102.1

113.3

131.3

147.4

173.4

202.4

211.7

235.5

254.7

EER

3.0

3.0

2.9

2.9

2.9

2.8

2.8

2.8

2.9

ESEER

3.8

4.1

4.1

4.1

3.8

4.0

4.0

4.2

4.0

Cooling capacity

kW

307.2

341.9

383.5

432.4

493.4

561.2

597.1

663.7

732.9

El. power consumption

kW

102.9

114.2

132.5

149.1

174.8

204.0

213.5

237.5

257.4

3.0

3.0

2.9

2.9

2.8

2.8

2.8

2.8

2.9

Performance values
according to
EN14511:2011

EER
ESEER

3.7

4.0

4.0

4.0

3.7

3.8

3.9

4.1

3.9

Max. current consumption

232.0

253.0

286.0

294.0

367.0

430.0

454.0

454.0

526.0

Max. power consumption

kW

141.0

152.0

176.0

180.0

221.0

259.0

275.0

275.0

322.0

Screw compressor

Quantity

Refrigeration Circuits

Quantity

Minimum partial load level

25

25

25

25

25

25

25

25

25

Sound power level

dB(A)

99

99

99

100

100

100

100

102

102

Sound pressure level

dB(A)

67

67

67

68

68

68

68

69

69

Length

mm

4000

4000

4000

4000

4900

4900

4900

5800

5800

Width

mm

2260

2260

2260

2260

2260

2260

2260

2260

2260

Height

mm

2500

2500

2500

2500

2500

2500

2500

2500

2500

Weight

kg

3480

3500

3510

3630

4730

4870

4960

5680

6170

Performance data
Sound power level
Sound pressure level

x24]

At chilled water 12/7C and air intake temperature 35C


EUROVENT certified figure, requirement specified by Eurovent 8/1 and ISO 9614
Rectangular-shaped radiation 10 m distance reflection factor Q=2
For project-related sound data calculations - use the obligatory sound power level!

PR-2014-0100-GB Subject to modifications K0-06/2014

Chiller outside installation air-cooled


GLAC 2150 4840 CA2 / .SL (.HE) 295 kW to 1818 kW

Refrigerant R-134a

GLAC

2360

2390

2420

2450

2480

2482

2541

2600

2602

Cooling capacity

kW

794.4

848.3

917.1

989.4

1051.1

1134.4

1213.4

1243.9

1328.1

El. power consumption

kW

279.7

303.5

323.7

344.4

357.5

398.8

417.8

443.5

465.2

EER

2.8

2.8

2.8

2.9

2.9

2.8

2.9

2.8

2.9

ESEER

3.9

3.9

4.0

4.0

4.1

4.1

4.1

4.0

4.2

Cooling capacity

kW

792.0

845.5

914.0

986.4

1047.5

1130.3

1210.2

1240.5

1324.0

El. power consumption

kW

282.1

306.3

326.9

347.4

361.0

402.9

421.1

447.0

469.3

EER

2.8

2.8

2.8

2.8

2.9

2.8

2.9

2.8

2.8

ESEER

3.7

3.7

3.9

3.9

3.9

4.0

4.0

3.9

4.1

Max. current consumption

590.0

635.0

673.0

722.0

763.0

763.0

852.0

926.0

926.0

Performance values according


to EN14511:2011

Max. power consumption

kW

365.0

390.0

410.0

440.0

466.0

466.0

518.0

562.0

562.0

Screw compressor

Quantity

Refrigeration Circuits

Quantity

Minimum partial load level

25

25

25

25

25

25

25

25

25

Sound power level

dB(A)

102

103

103

104

104

104

106

106

106

Sound pressure level

dB(A)

69

70

70

71

71

71

73

73

73

Length

mm

5800

7000

7000

7600

7600

7600

9400

9400

11200

Width

mm

2260

2260

2260

2260

2260

2260

2260

2260

2260

Height

mm

2500

2500

2500

2500

2500

2500

2500

2500

2500

Weight

kg

6560

7010

7220

7860

8030

8090

9290

9380

10040

Refrigerant R-134a

GLAC

3630

3690

3720

3721

3722

4840

Cooling capacity

kW

1397.7

1495.1

1616.4

1681.4

1740.8

1817.5

El. power consumption

kW

478.1

532.3

541.9

579.9

604.1

672.5

EER

2.9

2.8

3.0

2.9

2.9

2.7

ESEER

4.0

3.9

4.1

4.2

4.2

4.0

Cooling capacity

kW

1393.4

1490.0

1611.4

1675.9

1734.3

1811.6

El. power consumption

kW

482.4

537.5

546.9

585.5

610.7

678.4

2.9

2.8

3.0

2.9

2.8

2.7

Performance values according


to EN14511:2011

EER
ESEER

3.9

3.8

Max. current consumption

1021.0

1103.0

1144.0

1144.0

1144.0

1331.0

Max. power consumption

kW

621.0

673.0

699.0

699.0

699.0

812.0

Screw compressor

Quantity

Refrigeration Circuits

Quantity

Minimum partial load level

16

16

16

16

16

12

Sound power level

dB(A)

106

106

106

106

106

106

Sound pressure level

dB(A)

73

73

73

73

73

73

Length

mm

11200

11200

11200

11200

11200

12400

Width

mm

2260

2260

2260

2260

2260

2260

Height

mm

2500

2500

2500

2500

2500

2500

Weight

kg

11440

11780

12350

12420

12480

13650

Performance data
Sound power level
Sound pressure level

At chilled water 12/7C and air intake temperature 35C


EUROVENT certified figure, requirement specified by Eurovent 8/1 and ISO 9614
Rectangular-shaped radiation 10 m distance reflection factor Q=2
For project-related sound data calculations - use the obligatory sound power level!

PR-2014-0100-GB Subject to modifications K0-06/2014

x25]

Chiller outside installation air-cooled


GLAC 2150 4840 CA2 / .SL (.HE) 295 kW to 1818 kW

Refrigerant R-134a

GLAC.SL

2150

2170

2190

2192

2220

2265

2270

2272

2315

Cooling capacity

kW

295.0

325.5

377.7

425.1

485.8

558.3

592.4

662.2

726.6

El. power consumption

kW

98.3

115.5

131.2

147.2

168.6

197.8

208.1

231.4

250.7

EER

3.0

2.8

2.9

2.9

2.9

2.8

2.9

2.9

2.9

ESEER

4.1

4.1

4.1

4.3

4.0

4.1

4.1

4.3

4.1

Cooling capacity

kW

294.3

324.6

376.6

423.5

484.5

556.8

590.6

660.2

724.1

El. power consumption

kW

99.0

116.4

132.4

148.7

169.9

199.4

209.9

233.4

253.2

3.0

2.8

2.9

2.9

2.9

2.8

2.8

2.8

2.9

Performance values according to EN14511:2011

EER
ESEER

4.0

4.0

4.0

4.1

3.9

4.0

4.0

4.2

3.9

Max. current consumption

232.0

253.0

294.0

294.0

367.0

437.0

462.0

462.0

533.0

Max. power consumption

kW

141.0

152.0

180.0

180.0

221.0

263.0

279.0

279.0

326.0

Screw compressor

Quantity

Refrigeration Circuits

Quantity

Minimum partial load level

25

25

25

25

25

25

25

25

25

Sound power level

dB(A)

87

87

88

88

89

89

90

90

91

Sound pressure level

dB(A)

55

55

56

56

57

57

57

57

58

Length

mm

4000

4000

4000

4000

4900

4900

4900

5800

5800

Width

mm

2260

2260

2260

2260

2260

2260

2260

2260

2260

Height

mm

2500

2500

2500

2500

2500

2500

2500

2500

2500

Weight

kg

3870

3890

3970

4230

5340

5700

5810

6520

7190

Refrigerant R-134a

GLAC.SL

2360

2390

2420

2450

2480

2482

2541

2600

2602

Cooling capacity

kW

781.8

846.6

905.5

992.4

1032.6

1140.1

1175.8

1230.7

1293.5

El. power consumption

kW

275.9

290.3

317.8

335.7

361.1

392.0

419.9

436.0

472.1

EER

2.8

2.9

2.9

3.0

2.9

2.9

2.8

2.8

2.7

ESEER

3.9

4.0

4.0

4.1

4.1

4.3

4.2

4.1

4.2

Cooling capacity

kW

779.6

843.8

902.5

989.3

1029.2

1135.9

1172.8

1227.3

1289.7

El. power consumption

kW

278.2

293.1

320.8

338.7

364.5

396.1

422.9

439.4

475.9

2.8

2.9

2.8

2.9

2.8

2.9

2.8

2.8

2.7

Performance values according


to EN14511:2011

EER
ESEER

3.8

3.9

3.9

4.0

3.9

4.1

4.1

4.0

4.1

Max. current consumption

597.0

643.0

681.0

737.0

778.0

778.0

852.0

941.0

941.0

Max. power consumption

kW

369.0

394.0

414.0

448.0

474.0

474.0

518.0

570.0

570.0

Screw compressor

Quantity

Refrigeration Circuits

Quantity

25

25

25

25

25

25

25

25

25

Sound power level

dB(A)

91

92

92

93

93

94

94

94

94

Sound pressure level

dB(A)

58

59

59

60

60

61

61

61

61

Length

mm

4000

4000

4000

4000

4900

4900

4900

5800

5800

Width

mm

2260

2260

2260

2260

2260

2260

2260

2260

2260

Height

mm

2500

2500

2500

2500

2500

2500

2500

2500

2500

Weight

kg

7590

7950

8370

9530

9550

10120

10590

10830

10990

Minimum partial load level

Performance data
Sound power level
Sound pressure level

x26]

At chilled water 12/7C and air intake temperature 35C


EUROVENT certified figure, requirement specified by Eurovent 8/1 and ISO 9614
Rectangular-shaped radiation 10 m distance reflection factor Q=2
For project-related sound data calculations - use the obligatory sound power level!

PR-2014-0100-GB Subject to modifications K0-06/2014

Chiller outside installation air-cooled


GLAC 2150 4840 CA2 / .SL (.HE) 295 kW to 1818 kW

Refrigerant R-134a

GLAC.SL

3630

3690

3720

3721

3722

4840

Cooling capacity

kW

1358.9

1460.9

1531.3

1597.6

1654.4

1761.9

El. power consumption

kW

475.6

527.8

561.3

607.6

637.4

682.1

EER

2.9

2.8

2.7

2.6

2.6

2.6

ESEER

4.1

4.0

4.0

4.0

4.1

3.9

Cooling capacity

kW

1354.9

1456.0

1527.0

1592.7

1648.7

1756.5

El. power consumption

kW

479.6

532.6

565.6

612.5

643.1

687.5

EER

2.8

2.7

2.7

2.6

2.6

2.6

ESEER

3.9

3.9

3.9

3.9

3.9

3.8

Max. current consumption

1021.0

1103.0

1144.0

1144.0

1144.0

1346.0

Performance values according


to EN14511:2011

Max. power consumption

kW

621.0

673.0

699.0

699.0

699.0

820.0

Screw compressor

Quantity

Refrigeration Circuits

Quantity

Minimum partial load level

16

16

16

16

16

12

Sound power level

dB(A)

94

94

94

94

95

96

Sound pressure level

dB(A)

61

61

61

61

62

63

Length

mm

11200

11200

11200

11200

11200

11200

Width

mm

2260

2260

2260

2260

2260

2260

Height

mm

2500

2500

2500

2500

2500

2500

Weight

kg

12830

12880

13390

13430

13470

15230

Refrigerant R-134a

GLAC.HE

2150

2170

2190

2192

2220

2260

2265

2270

2272

Cooling capacity

kW

310.9

356.3

406.1

455.1

512.3

558.4

596.9

633.8

703.5

El. power consumption

kW

97.9

112.9

127.4

144.6

162.7

178.1

188.8

199.2

223.2

EER

3.2

3.2

3.2

3.2

3.2

3.1

3.2

3.2

3.2

ESEER

4.1

4.1

4.2

4.4

4.1

4.2

4.2

4.2

4.2

Cooling capacity

kW

310.1

355.3

404.7

454.0

510.8

556.8

595.1

631.6

701.2

El. power consumption

kW

98.6

113.9

128.8

145.8

164.2

179.6

190.6

201.4

225.6

EER

3.1

3.1

3.1

3.1

3.1

3.1

3.1

3.1

3.1

ESEER

4.0

4.0

4.1

4.2

3.9

4.1

4.0

4.1

4.0

Max. current consumption

232.0

260.0

294.0

294.0

367.0

406.0

437.0

462.0

477.0

Performance values according to EN14511:2011

Max. power consumption

kW

141.0

156.0

180.0

180.0

221.0

244.0

263.0

279.0

287.0

Screw compressor

Quantity

Refrigeration Circuits

Quantity

25

25

25

25

25

25

25

25

25

Sound power level

dB(A)

98

98

99

99

100

100

101

101

101

Sound pressure level

Minimum partial load level

dB(A)

66

66

67

67

68

67

68

68

68

Length

mm

4000

4000

4000

4000

4000

4000

4000

4000

4000

Width

mm

2260

2260

2260

2260

2260

2260

2260

2260

2260

Height

mm

2500

2500

2500

2500

2500

2500

2500

2500

2500

Weight

kg

3530

3650

3780

4260

4920

5370

5460

5920

6660

Performance data
Sound power level
Sound pressure level

At chilled water 12/7C and air intake temperature 35C


EUROVENT certified figure, requirement specified by Eurovent 8/1 and ISO 9614
Cube-shaped radiaton 10 m distance reflection factor Q=2
For project-related noise calculations, please only employ the binding sound power level!.

PR-2014-0100-GB Subject to modifications K0-06/2014

x27]

Chiller outside installation air-cooled


GLAC 2150 4840 CA2 / .SL (.HE) 295 kW to 1818 kW

Refrigerant R-134a

GLAC.HE

2315

2360

2390

2420

2450

2480

2482

2541

3570

Cooling capacity

kW

775.3

851.0

905.9

977.6

1049.6

1103.1

1202.9

1255.1

1362.9

El. power consumption

kW

244.5

268.5

286.3

307.0

326.9

345.6

377.2

400.2

433.1

EER

3.2

3.2

3.2

3.2

3.2

3.2

3.2

3.1

3.2

ESEER

4.1

3.9

4.0

4.1

4.2

4.2

4.2

4.2

4.0

Cooling capacity

kW

772.3

848.2

902.6

974.0

1046.0

1099.1

1198.1

1251.5

1360.6

El. power consumption

kW

247.5

271.4

289.7

310.6

330.4

349.6

381.9

403.7

435.4

EER

3.1

3.1

3.1

3.1

3.2

3.1

3.1

3.1

3.1

ESEER

3.9

3.8

3.9

3.9

4.0

4.0

4.0

4.1

3.9

Max. current consumption

541.0

605.0

650.0

696.0

737.0

778.0

793.0

867.0

945.0

Performance values according


to EN14511:2011

Max. power consumption

kW

330.0

373.0

398.0

422.0

448.0

474.0

482.0

526.0

581.0

Screw compressor

Quantity

Refrigeration Circuits

Quantity

Minimum partial load level

25

25

25

25

25

25

25

25

25

Sound power level

dB(A)

101

102

102

103

103

103

103

104

104

Sound pressure level

dB(A)

68

69

69

70

70

70

70

71

71

Length

mm

7600

7600

7600

7600

7600

7600

7600

7600

7600

Width

mm

2260

2260

2260

2260

2260

2260

2260

2260

2260

Height

mm

2500

2500

2500

2500

2500

2500

2500

2500

2500

Weight

kg

7070

7460

8220

8800

9340

9570

9820

10150

12270

Refrigerant R-134a

GLAC.HE

3630

3660

Cooling capacity

kW

1468.9

1542.8

El. power consumption

kW

467.9

491.3

EER

3.1

3.1

ESEER

4.2

4.2

Cooling capacity

kW

1466.1

1539.6

El. power consumption

Performance values according to


EN14511:2011

kW

470.7

494.4

EER

3.1

3.1

ESEER

4.1

0.0

Max. current consumption

1021.0

1062.0

Max. power consumption

kW

621.0

647.0

Screw compressor

Quantity

Refrigeration Circuits

Quantity

16

25

Sound power level

dB(A)

104

104

Sound pressure level

dB(A)

71

71

Length

mm

11200

11200

Width

mm

2260

2260

Height

mm

2500

2500

Weight

kg

12720

12830

Minimum partial load level

Performance data
Sound power level
Sound pressure level

x28]

At chilled water 12/7C and air intake temperature 35C


EUROVENT certified figure, requirement specified by Eurovent 8/1 and ISO 9614
Rectangular-shaped radiation 10 m distance reflection factor Q=2
For project-related sound data calculations - use the obligatory sound power level!

PR-2014-0100-GB Subject to modifications K0-06/2014

Chiller outside installation air-cooled


GLFC 0152 0612 BD2 / .SL 37 kW to 162 kW with free cooling

Equipment
Unit with a free-cooling function with high energy-saving potential
The free cooling mode is activated starting from 1 C temperature

difference between outdoor air and water


3-way valve for optimizing water circuits and efficiency
with 2 scroll compressors
Autoadaptive microprocessor control
Controller type: HVAC Systems Step II
Unit main switch
Master/slave operation with GEA HVAC System unit series availa-

ble as an accessory item


Connection to BMS via optional interface

Can be delivered in two different versions:


GLFC 0152 0612 BD2 as standard unit
GLFC 0152 0612 BD2.SL in especially quiet version

Refrigerant R -410A

GLFC

0152

0182

0202

0252

0302

0352

0412

0452

0512

0552

0612

Cooling capacity

kW

37.4

44.3

53.5

58.7

76.7

90.3

99.2

113.4

129.2

143.9

161.6

El. power consumption

kW

15.2

16.4

20.7

23.9

30.1

32.7

37.7

43.3

46.2

54.2

62.8

2.5

2.7

2.6

2.5

2.6

2.8

2.6

2.6

2.8

2.7

2.6

Cooling capacity

kW

37.0

43.9

52.9

58.0

75.8

89.4

98.4

112.4

127.8

142.7

160.2

El. power consumption

kW

15.6

16.9

21.3

24.5

30.9

33.6

38.5

44.3

47.6

55.5

64.3

2.4

2.6

2.5

2.4

2.5

2.7

2.6

2.5

2.7

2.6

2.5

Max. current consumption

33.6

35.8

48.4

52.8

63.4

71.6

79.8

93.3

103.0

116.1

133.0

Max. power consumption

kW

19.5

21.7

27.8

30.6

38.0

43.4

48.8

56.0

61.1

69.5

80.0

Scroll
compressor

Quantity

Refrigeration Circuits

Quantity

Capacity stages

Quantity

Sound power level

dB(A)

87

87

90

90

91

91

92

92

93

93

94

Sound pressure level

EER
Performance values according to EN14511:2011

EER

dB(A)

55

55

58

58

59

59

60

60

61

61

62

Length

mm

2200

2200

2602

2602

2602

3602

3602

3602

4602

4602

4602

Width

mm

920

920

1104

1104

1104

1104

1104

1104

1104

1104

1104

Height

mm

1780

1780

2175

2175

2175

2175

2175

2175

2175

2205

2205

Weight

kg

670

710

870

880

1060

1310

1340

1410

1650

1680

1740

Performance data
*Free-cooling mode
Sound power level
Sound pressure level

Performance data in normal mode with chilled water 12/7C and air inlet temperature 35C with 30% ethylene glycol
Performance data in optimized conditions with chilled water free-cooling 15/10 with 30% ethylene glycol
Requirement specified by ISO 3744
Rectangular-shaped radiation 10 m distance reflection factor Q=2
For project-related sound data calculations - use the obligatory sound power level!

PR-2014-0100-GB Subject to modifications K0-06/2014

x29]

Chiller outside installation air-cooled


GLFC 0152 0612 BD2 / .SL 37 kW to 162 kW with free cooling

Free cooling operation*

GLFC

0152

0182

0202

0252

0302

0352

0412

0452

0512

0552

0612

Cooling capacity

kW

41.0

48.0

58.0

64.0

83.0

98.0

108.0

123.0

140.0

156.0

175.0

El. power consumption

kW

16.0

17.0

21.0

24.0

32.0

34.0

39.0

45.0

47.0

56.0

65.0

Cooling capacity

kW

31.0

36.0

42.0

44.0

55.0

70.0

72.0

84.0

99.0

102.0

114.0

Share of free-cooling capacity

77.0

74.0

73.0

69.0

66.0

71.0

67.0

68.0

70.0

65.0

65.0

Cooling capacity

kW

41.0

48.0

58.0

64.0

83.0

98.0

108.0

123.0

140.0

156.0

175.0

power consumption

kW

1.5

1.5

4.2

4.2

4.2

4.2

4.2

6.3

6.3

6.3

8.4

Air Inlet Temperature

2.0

1.6

1.3

0.5

-0.1

0.9

0.0

0.2

0.8

-0.3

-0.3

27.0

32.0

13.8

15.0

19.8

23.4

25.7

19.5

22.3

24.8

20.9

GLFC.SL

0152

0182

0202

0252

0302

0352

0412

0452

0512

0552

0612

Cooling capacity

kW

35.4

43.2

48.5

54.7

72.3

84.2

96.1

105.2

118.4

134.0

154.3

El. power consumption

kW

15.4

17.1

20.4

23.3

29.9

34.2

37.6

43.6

48.3

56.1

62.4

2.3

2.5

2.4

2.4

2.4

2.5

2.6

2.4

2.5

2.4

2.5

Cooling capacity

kW

35.0

42.7

48.0

54.1

71.5

83.4

95.3

104.3

117.3

132.7

152.7

El. power consumption

Performance data without


free cooling operation at
35 C outdoor temperature

Performance data with


free cooling operation at 5
C outdoor temperature

Capacity data at 100 % freecooling mode

EER

Refrigerant R -410A

EER
Performance values
as of EN14511:2011

kW

15.7

17.5

20.9

23.9

30.7

35.0

38.4

44.5

49.5

57.4

64.0

EER

2.2

2.5

2.3

2.3

2.3

2.4

2.5

2.3

2.4

2.3

2.4

Max. current consumption

32.4

40.4

48.4

52.8

63.4

75.4

83.6

93.3

106.8

119.9

133.0

Max. power consumption

kW

18.9

22.6

26.0

28.8

36.2

42.8

48.2

53.3

59.6

68.0

76.4

Scroll
compressor

Quantity

Refrigeration Circuits

Quantity

Capacity stages

Quantity

Sound power level

dB(A)

77

78

78

79

80

81

81

82

83

84

85

Sound pressure level

dB(A)

45

46

46

47

48

49

49

50

51

51

52

Length

mm

2200

2602

2602

2602

3602

3602

4602

4602

4602

4602

4602

Width

mm

920

1104

1104

1104

1104

1104

1104

1104

1104

1277

1277

Height

mm

1780

2175

2175

2175

2175

2175

2205

2175

2205

2350

2350

Weight

kg

680

860

920

940

1240

1350

1590

1610

1690

1920

2000

Performance data
*Free-cooling mode
Sound power level
Sound pressure level

x30]

Performance data in normal mode with chilled water 12/7C and air inlet temperature 35C with 30% ethylene glycol
Performance data in optimized conditions with chilled water free-cooling 15/10 with 30% ethylene glycol
Requirement specified by ISO 3744
Rectangular-shaped radiation 10 m distance reflection factor Q=2
For project-related sound data calculations - use the obligatory sound power level!

PR-2014-0100-GB Subject to modifications K0-06/2014

Chiller outside installation air-cooled


GLFC 0152 0612 BD2 / .SL 37 kW to 162 kW with free cooling

Free cooling operation*

GLFC.SL

0152

0182

0202

0252

0302

0352

0412

0452

0512

0552

0612

Cooling capacity

kW

38.0

47.0

53.0

59.0

79.0

92.0

105.0

114.0

128.0

145.0

167.0

El. power consumption

kW

16.0

18.0

21.0

24.0

31.0

34.0

39.0

45.0

50.0

58.0

64.0

Cooling capacity

kW

25.0

30.0

34.0

38.0

50.0

59.0

69.0

72.0

80.0

90.0

98.0

Share of free-cooling
capacity

77.0

74.0

73.0

69.0

66.0

71.0

67.0

68.0

70.0

65.0

65.0

Cooling capacity

kW

38.0

47.0

53.0

59.0

79.0

92.0

105.0

114.0

128.0

145.0

167.0

Power consumption

kW

0.6

1.5

1.5

1.7

1.7

2.6

2.6

2.6

3.4

3.4

4.4

Air Inlet Temperature

-0.5

-0.9

-0.5

-0.6

-0.8

-0.6

-0.2

-0.9

-0.9

-1.1

-2.1

63.7

31.3

35.0

34.6

46.2

35.2

40.3

43.8

37.6

42.5

37.9

Performance data without free cooling operation at 35 C outdoor


temperature

Performance data with free


cooling operation at 5 C
outdoor temperature

Capacity data at 100 %


free-cooling mode

EER
Performance data
*Free-cooling mode
Sound power level
Sound pressure level

Performance data in normal mode with chilled water 12/7C and air inlet temperature 35C with 30% ethylene glycol
Performance data in optimized conditions with chilled water free-cooling 15/10 with 30% ethylene glycol
Requirement specified by ISO 3744
Rectangular-shaped radiation 10 m distance reflection factor Q=2
For project-related sound data calculations - use the obligatory sound power level!

PR-2014-0100-GB Subject to modifications K0-06/2014

x31]

Chiller outside installation air-cooled


GLFC 0604 ... 1204 BD2 / .SL 153 kW to 326 kW with free cooling

Equipment
Unit with a free-cooling function with high energy-saving potential
The free-cooling operation begins from 1 C temperature difference

between outdoor air and water


3-way valve for optimizing water circuits and efficiency
with 4 scroll compressors in two refrigeration circuits
Autoadaptive microprocessor control
Controller type: HVAC Systems Step II
Unit main switch
Master/slave operation with GEA HVAC System unit series availa-

ble as an accessory item


Connection to BMS via optional interface

Can be delivered in two different versions:


GLFC 0604 ... 1204 BD2 as standard unit
GLFC 0604 ... 1204 BD2.SL in especially quiet Ausfhrung

Refrigerant R -410A

GLFC

0604

0704

0804

0904

1004

1104

1204

Cooling capacity

kW

153.7

179.1

202.5

231.9

253.9

291.0

326.3

El. power consumption

kW

60.0

66.2

77.5

84.2

94.4

107.0

124.2

2.6

2.7

2.6

2.8

2.7

2.7

2.6

Cooling capacity

kW

152.1

176.9

199.8

229.7

251.4

287.9

322.6

El. power consumption

kW

61.6

68.3

80.3

86.4

96.9

110.0

127.9

2.5

2.6

2.5

2.7

2.6

2.6

2.5

Max. current consumption

126.8

143.2

167.2

186.6

206.0

232.2

266.0

Max. power consumption

kW

76.0

86.8

101.8

112.0

122.2

139.0

160.0

Scroll
compressor

Quantity

Refrigeration Circuits

Quantity

Capacity stages

Quantity

Sound power level

dB(A)

93

93

94

94

94

95

96

Sound pressure level

EER
Performance values according
to EN14511:2011

EER

dB(A)

61

61

62

62

62

63

64

Length

mm

4110

4110

4110

5110

5110

5110

5110

Width

mm

2220

2220

2220

2220

2220

2220

2220

Height

mm

2150

2150

2150

2150

2150

2430

2430

Weight

kg

2200

2330

2510

2880

2940

3260

3400

Performance data
*Free-cooling mode
Sound power level
Sound pressure level

x32]

Performance data in normal mode with chilled water 12/7C and air inlet temperature 35C with 30% ethylene glycol
Performance data in optimized conditions with chilled water free-cooling 15/10 with 30% ethylene glycol
Requirement specified by ISO 3744
Rectangular-shaped radiation 10 m distance reflection factor Q=2
For project-related sound data calculations - use the obligatory sound power level!

PR-2014-0100-GB Subject to modifications K0-06/2014

Chiller outside installation air-cooled


GLFC 0604 ... 1204 BD2 / .SL 153 kW to 326 kW with free cooling

Free cooling operation*

GLFC

0604

0704

0804

0904

1004

1104

1204

Cooling capacity

kW

167.0

195.0

221.0

252.0

275.0

316.0

354.0

El. power consumption

kW

62.0

68.0

80.0

86.0

97.0

110.0

128.0

Cooling capacity

kW

129.0

135.0

156.0

193.0

199.0

227.0

254.0

Share of free-cooling capacity

77.0

69.0

71.0

77.0

72.0

72.0

72.0

Cooling capacity

kW

167.0

195.0

221.0

252.0

275.0

316.0

354.0

Power consumption

kW

8.4

8.4

12.6

12.6

12.6

12.6

16.8

Air Inlet Temperature

2.0

0.5

0.9

1.9

1.2

1.1

1.0

19.9

23.2

17.5

20.0

21.8

25.0

21.1

GLFC.SL

0604

0704

0804

0904

1004

1104

1204

Cooling capacity

kW

142.5

165.4

184.8

208.8

236.1

269.7

302.5

El. power consumption

kW

61.0

70.0

79.1

87.9

95.3

109.7

125.9

2.3

2.4

2.3

2.4

2.5

2.5

2.4

Cooling capacity

kW

141.1

163.7

182.7

207.1

234.0

267.2

299.4

El. power consumption

kW

62.3

71.8

81.3

89.6

97.4

112.2

128.9

2.3

2.3

2.3

2.3

2.4

2.4

2.3

Max. current consumption

126.8

150.8

167.2

186.6

206.0

232.2

266.0

Max. power consumption

kW

72.4

85.6

96.4

106.6

116.8

133.6

152.8

Scroll
compressor

Quantity

Refrigeration Circuits

Quantity

Capacity stages

Quantity

Sound power level

dB(A)

82

83

83

84

84

85

86

Sound pressure level

dB(A)

50

51

51

52

52

53

54

Length

mm

4110

4110

4110

5110

5110

5110

5110

Width

mm

2220

2220

2220

2220

2220

2220

2220

Height

mm

2150

2150

2150

2150

2150

2430

2430

Weight

kg

2280

2410

2580

2880

3040

3380

3520

Performance data without


free cooling operation at 35 C
outside temperature

Performance data with free


cooling operation at 5 C outdoor temperature

Capacity data at 100 % free-cooling mode

EER

Refrigerant R -410A

EER
Performance values according
to EN14511:2011

EER

Performance data
*Free-cooling mode
Sound power level
Sound pressure level

Performance data in normal mode with chilled water 12/7C and air inlet temperature 35C with 30% ethylene glycol
Performance data in optimized conditions with chilled water free-cooling 15/10 with 30% ethylene glycol
Requirement specified by ISO 3744
Rectangular-shaped radiation 10 m distance reflection factor Q=2
For project-related sound data calculations - use the obligatory sound power level!

PR-2014-0100-GB Subject to modifications K0-06/2014

x33]

Chiller outside installation air-cooled


GLFC 0604 ... 1204 BD2 / .SL 153 kW to 326 kW with free cooling

Free cooling operation*

GLFC.SL

0604

0704

0804

0904

1004

1104

1204

Cooling capacity

kW

155.0

180.0

201.0

226.0

255.0

291.0

326.0

El. power consumption

kW

63.0

73.0

82.0

91.0

98.0

113.0

130.0

Cooling capacity

kW

97.0

112.0

115.0

140.0

148.0

166.0

188.0

Share of free-cooling capacity

63.0

62.0

57.0

62.0

58.0

57.0

58.0

Cooling capacity

kW

155.0

180.0

201.0

226.0

255.0

291.0

326.0

power consumption

kW

3.4

5.2

5.2

5.2

5.2

5.2

6.9

Air Inlet Temperature

-1.0

-1.0

-2.5

-1.1

-2.2

-2.5

-2.4

45.5

34.6

38.7

43.5

49.0

56.0

47.3

Performance data without


free cooling operation at 35 C
outdoor temperature

Performance data with free


cooling operation at 5 C outdoor temperature

Capacity data at 100 % free-cooling mode

EER
Performance data
*Free-cooling mode
Sound power level
Sound pressure level

x34]

Performance data in normal mode with chilled water 12/7C and air inlet temperature 35C with 30% ethylene glycol
Performance data in optimized conditions with chilled water free-cooling 15/10 with 30% ethylene glycol
Requirement specified by ISO 3744
Rectangular-shaped radiation 10 m distance reflection factor Q=2
For project-related sound data calculations - use the obligatory sound power level!

PR-2014-0100-GB Subject to modifications K0-06/2014

Chiller outside installation air-cooled


GLFC 2150 ... 2600 DA2 / .SL 286 kW to 1212 kW with free cooling

Equipment
Unit with a free-cooling function with high energy-saving potential
The free cooling mode is activated starting from 1 C temperature

difference between outdoor air and water


3-way valve for optimizing water circuits and efficiency
Autoadaptive microprocessor control
Controller type: HVAC Systems Step III
Unit main switch
Master/slave operation with GEA HVAC System unit series availa-

ble as an accessory item


Connection to BMS via optional interface

Can be delivered in two different versions:


GLFC 2150 ... 2600 DA2 as standard unit
GLFC 2150 ... 2540 DA2.SL as especially quiet version

Refrigerant R-134a GLFC 2150 2170 2190 2200 2220 2260 2270 2300 2320 2340 2360 2390 2420 2450 2480

2540

2600

Cooling capacity

kW

286.0

320.2

370.6

412.6

454.9

529.8

570.4

596.1

646.0

709.1

754.8

807.5

866.5

938.4 1025.7 1140.9 1212.4

El. power consumption

kW

92.4

106.6

119.3

138.3

146.8

179.5

192.4

207.6

219.7

233.8

256.2

275.5

286.9

317.3

331.8

386.1

429.6

3.1

3.0

3.1

3.0

3.1

3.0

3.0

2.9

2.9

3.0

3.0

2.9

3.0

3.0

3.1

3.0

2.8

Cooling capacity

kW

284.6

318.4

368.7

410.3

453.0

527.3

568.1

593.5

643.5

706.0

751.5

803.2

861.9

934.0 1020.2 1135.4 1205.9

El. power consumption

kW

93.7

108.4

121.1

140.6

148.7

182.0

194.7

210.2

222.2

236.9

259.6

279.8

291.5

321.6

337.3

391.6

436.1

EER

3.0

2.9

3.0

2.9

3.1

2.9

2.9

2.8

2.9

3.0

2.9

2.9

3.0

2.9

3.0

2.9

2.8

Max. current consumption

234.0

241.0

262.0

303.0

314.0

377.0

414.0

439.0

471.0

506.0

533.0

572.0

609.0

663.0

716.0

800.0

882.0

EER
Performance values
as of EN14511:2011

kW

116.0

145.0

157.0

185.0

192.0

226.0

248.0

264.0

284.0

306.0

324.0

350.0

375.0

404.0

433.0

485.0

537.0

Screw compressor

Quantity

Refrigeration Circuits

Quantity

Max. power consumption

25

25

25

25

25

25

25

25

25

25

25

25

25

25

25

25

25

Sound power level

dB(A)

99.0

100.0

100.0

100.0

101.0

102.0

102.0

102.0

102.0

102.0

103.0

103.0

103.0

105.0

106.0

106.0

106.0

Sound pressure level

dB(A)

66.4

67.4

67.3

67.3

68.2

69.2

69.1

69.1

69.0

68.9

69.9

69.9

69.7

71.7

72.5

72.5

72.4

Length

mm

4000

4000

4900

4900

5800

5800

6400

6400

7000

7900

7900

7900

10000 10000 11800

11800 13000

Width

mm

2260

2260

2260

2260

2260

2260

2260

2260

2260

2260

2260

2260

2260

2260

2260

2260

2260

Height

mm

2500

2500

2500

2500

2500

2500

2500

2500

2500

2500

2500

2500

2500

2500

2500

2500

2500

Weight

kg

4880

4990

5520

5700

7000

7410

8270

8310

8750

9600

10470 10570 12680 13180 13710

Minimum partial load level

Performance data
*Free-cooling mode
Sound power level
Sound pressure level

14930 15810

Performance data in normal mode with chilled water 12/7C and air inlet temperature 35C with 30% ethylene glycol
Performance data in optimized conditions with chilled water free-cooling 15/10 with 30% ethylene glycol
Requirement specified by ISO 3744
Rectangular-shaped radiation 10 m distance reflection factor Q=2
For project-related sound data calculations - use the obligatory sound power level!

PR-2014-0100-GB Subject to modifications K0-06/2014

x35]

Chiller outside installation air-cooled


GLFC 2150 ... 2600 DA2 / .SL 286 kW to 1212 kW with free cooling
Free cooling oper- GLFC 2150 2170 2190 2200 2220 2260 2270 2300 2320 2340 2360 2390 2420 2450 2480 2540 2600
ation*
Performance data without free cooling operation at 35 C outdoor
temperature

Cooling capacity

kW

314.0

351.5

407.3

452.8

501.1

580.6

625.8

653.1

708.6

777.8

826.6

882.8

946.8

1027

1125

1250

1329

El. power consumption

kW

96.2

111.0

124.1

144.0

153.0

187.3

200.8

216.9

229.3

243.0

266.7

287.2

298.8

330.4

344.5

402.5

447.5

Cooling capacity

kW

208.9

237.4

272.8

304.1

337.0

397.7

424.6

433.1

482.4

517.5

556.6

573.3

613.1

674.1

747.9

821.7

873.2

Share of free-cooling
capacity

67.0

68.0

67.0

67.0

67.0

68.0

68.0

66.0

68.0

67.0

67.0

65

65

66

66

66

66

Cooling capacity

kW

314.0

351.5

407.3

452.8

501.1

580.6

625.8

653.1

708.6

777.8

826.6

882.8

946.8

1027

1125

1250

1329

Power consumption

kW

11.9

15.9

15.9

19.9

19.9

23.9

23.9

23.9

27.8

31.8

31.8

31.8

31.8

39.8

47.7

47.7

47.7

Air Inlet Temperature

1.6

1.8

1.7

1.8

1.8

2.1

2.1

1.8

2.1

1.6

2.0

1.5

1.5

1.7

1.6

1.7

1.7

26.4

22.1

25.6

22.8

25.2

24.3

26.2

27.3

25.5

24.5

26.0

27.8

29.8

25.8

23.6

26.2

27.9

Performance data
with free cooling operation at 5 C outdoor temperature

Capacity data at 100


% free-cooling mode

EER

Refrigerant R-134a GLFC.SL

2150

Cooling capacity

kW

282.2 319.4 364.5 407.4 446.7 534.6 561.9 610.6 638.2 673.5 750.9 839.7 801.3 940.4 979.7 1107.0

El. power consumption

kW

93.3

3.0

EER

2170

2190

2200

2220

2260

2270

2300

2320

2340

2360

2390

2420

2450

2480

103.0 120.6 135.4 148.7 174.1 194.1 201.4 219.7 242.2 255.6 293.8 276.3 312.0 340.8
3.1

3.0

3.0

3.0

3.0

2.9

3.0

2.9

2.8

2.9

2.9

2.9

3.0

2.9

2540

391.9
2.8

Performance values
as of EN14511:2011
Cooling capacity

kW

280.9 317.6 362.7 405.3 445.0 532.0 559.7 607.8 635.8 670.7 747.8 835.4 797.4 936.0 974.9 1101.8

El. power consumption

kW

94.6

EER

2.9

Max. current consumption

241.0 241.0 269.0 303.0 321.0 384.0 422.0 454.0 479.0 506.0 549.0 624.0 587.0 678.0 716.0

800.0

kW

120.0 145.0 161.0 185.0 196.0 230.0 252.0 272.0 288.0 306.0 332.0 383.0 358.0 412.0 433.0

485.0

Max. power consumption

104.8 122.4 137.6 150.4 176.7 196.3 204.1 222.1 244.9 258.7 298.1 280.2 316.4 345.7
3.0

2.9

2.9

2.9

3.0

2.9

3.0

2.9

2.7

2.9

2.8

2.9

3.0

2.8

397.0
2.9

Screw compressor

Quantity

Refrigeration Circuits

Quantity

Minimum partial load


level

25

25

25

25

25

25

25

25

25

25

25

25

25

25

25

25

Sound power level

dB(A)

89.0

89.0

89.0

90.0

91.0

91.0

91.0

92.0

92.0

92.0

92.0

92.0

92.0

94.0

94.0

95.0

Sound pressure level

dB(A)

56.8

56.7

56.7

57.6

58.4

58.3

58.3

59.2

59.2

59.2

58.9

58.9

58.9

61.0

61.0

61.9

Length

mm

4000

4900

4900

5800

5800

7000

7000

7900

7900

7900 10000 10000 10000 11800 11800 13000

Width

mm

2260

2260

2260

2260

2260

2260

2260

2260

2260

2260

2260

2260

2260

2260

2260

2260

Height

mm

2500

2500

2500

2500

2500

2500

2500

2500

2500

2500

2500

2500

2500

2500

2500

2500

Weight

kg

5380

5950

6040

6600

7500

8250

9070

9550 10040 10590 13020 13560 13060 14970 15060 16360

Performance data
*Free-cooling mode
Sound power level
Sound pressure level

x36]

Performance data in normal mode with chilled water 12/7C and air inlet temperature 35C with 30% ethylene glycol
Performance data in optimized conditions with chilled water free-cooling 15/10 with 30% ethylene glycol
Requirement specified by ISO 3744
Rectangular-shaped radiation 10 m distance reflection factor Q=2
For project-related sound data calculations - use the obligatory sound power level!

PR-2014-0100-GB Subject to modifications K0-06/2014

Chiller outside installation air-cooled


GLFC 2150 ... 2600 DA2 / .SL 286 kW to 1212 kW with free cooling

Free cooling oper- GLFC.SL 2150 2170 2190 2200 2220 2260 2270 2300 2320 2340 2360 2390 2420 2450 2480 2540
ation*
Performance data
without free cooling
operation at 35 C
outdoor temperature
Cooling capacity

kW

309.3

350.1

399.6

446.2

491.1

585.4

615.2

669.3

698.6

735.3

821.0

874

912.7

1028

1071

1209

El. power consumption

kW

97.4

107.6

125.8

141.7

155.6

182.1

203.4

210.5

230.1

253.9

267.1

288.9

307.1

325.8

356.6

411

Cooling capacity

kW

201.7

221.5

257.5

283.4

327.5

376.2

400.4

431.8

458.3

469.9

541.5

558.2

570.2

669.5

682.9

743.1

Share of free-cooling
capacity

65.0

63.0

64.0

64.0

67.0

64.0

65.0

65.0

66.0

64.0

66.0

64

62

65

64

61

Cooling capacity

kW

309.3

350.1

399.6

446.2

491.1

585.4

615.2

669.3

698.6

735.3

821.0

874

912.7

1028

1071

1209

Power consumption

kW

9.5

9.5

11.9

11.9

14.3

16.7

16.7

19.1

19.3

19.1

23.9

23.8

23.8

28.6

28.6

28.6

Air Inlet Temperature

1.0

1.0

1.0

0.9

1.0

0.9

1.3

1.0

1.3

1.0

1.3

0.9

0.6

1.2

0.9

0.4

32.4

36.7

33.6

37.5

34.3

35.1

36.8

35.0

36.2

38.5

34.4

36.7

38.3

35.9

37.4

42.3

Performance data
with free cooling operation at 5 C outdoor temperature

Capacity data at 100


% free-cooling mode

EER
Performance data
*Free-cooling mode
Sound power level
Sound pressure level

Performance data in normal mode with chilled water 12/7C and air inlet temperature 30C with 30% ethylene glycol
Performance data in optimized conditions with chilled water free-cooling 15/10 with 30% ethylene glycol
Requirement specified by ISO 3744
Rectangular-shaped radiation 10 m distance reflection factor Q=2
For project-related sound data calculations - use the obligatory sound power level!

PR-2014-0100-GB Subject to modifications K0-06/2014

x37]

Compressor/condensing unit outside installation air-cooled


GLCU 2015 ... 4060 BC1/2 / .SL 40 kW to 171 kW

Equipment
Standard configuration with 2 or 4 scroll compressors

2-circuit system
Frame and panels made of galvanized steel
Coated plastic
Condenser made of copper pipes and corrugated aluminium fins
Cooling operation down to -15 C ambient temperature
Activation on-site

Switch cabinet produced according to EN60204-1 / IEC204-1


Unit main switch
Shut off valve in liquid and suction line
High and low pressure switch

Can be delivered in two different versions:

Continuously variable fan speed control

GLCU 2015 ... 4060 BC1 as standard unit

Recommended accessories

GLCU 4052 ... 4060 BC2.SL in especially quiet version

Refrigerating engineering accessories GLZCU... .R06


(expansion valve, solenoid valve, filter drier and sight glass, to be
mounted in each circuit by others on site)

GLCU(.SL)

2015

2018

2020

2025

2030

2041

2051

4052

4060

4052
.SL

4060
.SL

Cooling capacity

kW

40.3

50.4

58.5

71.1

85.2

120.2

148.0

150.8

171.1

141.0

161.6

El. power consumption

kW

14.8

18.2

20.7

25.9

30.2

38.8

47.4

56.5

65.9

55.2

64.7

R -407C refrigerant

EER

2.7

2.8

2.8

2.8

2.8

3.1

3.1

2.7

2.6

2.6

2.5

Max. current consumption

31.4

41.3

46.7

59.7

64.7

88.0

105.0

115.0

129.0

115.0

129.0

Max. power consumption

kW

16.2

19.4

22.2

27.7

36.7

50.3

60.5

66.0

76.4

62.4

72.8

Scroll
compressor

Quantity

Refrigeration Circuits

Quantity

Capacity stages

Quantity

Sound power level

dB(A)

78

79

79

81

81

85

85

94

94

79

79

Sound pressure level

dB(A)

47

47

48

50

50

53

53

62

62

47

47

Length

mm

1695

2195

2195

2745

2745

3245

3245

3110

3110

3110

3110

Width

mm

1120

1120

1120

1120

1120

1120

1120

2220

2220

2220

2220

Height

mm

1420

1420

1420

1420

1420

1620

1620

1700

1700

1700

2150

Weight

kg

510

570

600

675

775

910

980

1520

1600

1620

1700

Performance data
Sound power level
Sound pressure level

x38]

Only the model sizes 4052 and 4060 are available as SL units
At evaporation temperature 7 C and air inlet temperature 35 C
Requirement specified by ISO 3744
Rectangular-shaped radiation 10 m distance reflection factor Q=2
For project-related sound data calculations - use the obligatory sound power level!

PR-2014-0100-GB Subject to modifications K0-06/2014

Chiller inside installation air cooled


GSDC 0011 ... 0041 FD5 / FD1 4.9 kW to 15.4 kW

Equipment
Optimized packaged model with 1 scroll compressor
Standard pump module integrated

additionally fitted with safety valve, expansion tank, pressure


gauge, air vent and fill connection
Following pump heads for pipework provided on-site
Second pump to enlarge the delivery head

as option for model sizes 0041 ... 0061


Buffer tank to be mounted below the unit is available as an option
Cooling operation down to -10 C air inlet temperature
Condensing pressure is used to regulate fan speed
Centrifugal fan for pressure-side duct connection

Can be delivered in two different versions:

Autoadaptive microprocessor control

GSDC 0011 ... 0041 FD5 with 230 V supply voltage


GSDC 0021 ... 0061 FD1 with 400 V supply voltage

Supply voltage

Refrigerant R-410a

1~230 Volt (Series FD5)

3~400 Volt (Series FD1)

GSDC

0011

0021

0025

0031

0041

0021

0025

0031

0041

0051

0061

Cooling capacity

kW

4.9

5.6

6.9

8.6

11.0

5.6

7.0

8.7

11.4

13.2

15.4

Max. external pressure

Pa

200.0

100.0

200.0

80.0

80.0

100.0

200.0

80.0

80.0

80.0

70.0

ESEER

2.2

2.5

2.7

2.6

2.4

2.5

2.8

2.7

2.5

2.5

2.8

Max. current consumption

20.3

20.3

23.3

27.3

31.3

9.8

10.3

12.3

14.3

16.1

19.3

Max. power consumption

kW

2.5

2.6

3.1

4.0

5.2

2.6

3.0

3.7

5.3

5.8

6.4

Scroll
compressor

Quantity

Refrigeration Circuits

Quantity

Capacity stages

Quantity

Delivery head remaining


pipework

kPa

59.0

57.0

54.0

54.0

43.0

57.0

54.0

54.0

40.0

33.0

30.0

Rated volume flow

m/h

0.8

1.0

1.2

1.5

1.9

1.0

1.2

1.5

2.0

2.3

2.7

Sound power level

dB(A)

68

68

68

68

71

68

68

68

71

71

71

Sound pressure level

dB(A)

40

40

40

40

43

40

40

40

43

43

43

Length

mm

900

900

900

900

900

900

900

900

900

900

900

Width

mm

580

580

580

580

580

580

580

580

580

580

630

Height

mm

640

640

940

940

1240

640

940

940

1240

1240

1390

Weight

kg

100

105

120

125

165

105

120

125

165

185

195

Performance data
Sound power level
Sound pressure level

At chilled water 12/7C and air intake temperature 35C


Requirement specified by Eurovent 8/1 and ISO 9614
Rectangular-shaped radiation 10 m distance reflection factor Q=2
For project-related sound data calculations - use the obligatory sound power level!

PR-2014-0100-GB Subject to modifications K0-06/2014

x39]

Chiller inside installation air cooled


GLDC 0152 1204 BD2 37 kW to 312 kW

Equipment
Standard configuration with 2 or 4 scroll compressors
Pump module is optional (hydraulic module GLPE) additionally fit-

ted with a safety valve, air vent and fill connection


Cooling operation down to -10 C air inlet temperature
Autoadaptive microprocessor control
Controller type: HVAC Systems Step I (0152 ...0612)

HVAC Systems Step II (0604 ...1204)


Unit main switch
Master/slave operation with GEA HVAC System unit series availa-

ble as an accessory item


Connection to BMS via optional interface
Configuration with a centrifugal fan
Pressure and suction side duct connection

Refrigerant R -410A

GLDC

0152

0182

0202

0252

0302

0352

0412

0452

0512

0552

0612

Cooling capacity

kW

37.1

43.0

50.5

57.0

74.8

86.4

97.9

108.8

120.9

137.7

158.7

Max. external pressure

Pa

480

380

370

370

230

420

410

310

300

340

310

El. power consumption

kW

15.7

18.3

20.6

23.2

30.4

36.8

40.7

46.8

51.5

58.3

67.2

EER

2.4

2.4

2.5

2.5

2.5

2.4

2.4

2.3

2.4

2.4

2.4

ESEER

4.7

4.3

4.5

4.4

4.2

3.9

3.9

3.7

3.7

4.2

3.9

Cooling capacity

kW

36.8

42.7

50.2

56.6

74.3

86.0

97.4

108.3

120.3

137.0

158.0

El. power consumption

Performance values as
of EN14511:2011

kW

14.2

16.7

19.0

21.5

28.7

33.6

37.7

43.5

48.4

55.2

62.3

EER

2.6

2.6

2.6

2.6

2.6

2.6

2.6

2.5

2.5

2.5

2.5

ESEER

4.4

4.0

4.2

4.1

4.0

3.7

3.7

3.6

3.6

3.8

3.6

Max. current consumption

37.6

39.8

47.8

52.2

65.6

80.8

89.0

98.7

108.4

121.5

143.0

Max. power consumption

kW

21.0

23.2

26.6

29.4

38.2

47.2

52.6

57.7

62.8

71.2

83.6

Scroll compressor

QTY

Refrigeration Circuits

QTY

Capacity stages

QTY

Sound power level

dB(A)

85

88

88

88

90

95

95

96

96

96

98

Sound pressure level

dB(A)

53

56

56

56

58

63

63

64

64

64

66

Length

mm

2200

2200

2200

2200

2200

2602

2602

2602

2602

3602

3602

Width

mm

920

920

920

920

920

1104

1104

1104

1104

1104

1104

Height

mm

1642

1642

1642

1642

1642

1927

1927

1927

1927

1927

1927

kg

670

670

700

720

880

1120

1170

1210

1260

1450

1550

Weight
Performance data
Sound power level
Sound pressure level

x40]

At chilled water 12/7C and air intake temperature 35C


EUROVENT certified figure, requirement specified by Eurovent 8/1 and ISO 9614
Rectangular-shaped radiation 10 m distance reflection factor Q=2
For project-related sound data calculations - use the obligatory sound power level!

PR-2014-0100-GB Subject to modifications K0-06/2014

Chiller inside installation air cooled


GLDC 0152 1204 BD2 37 kW to 312 kW

Refrigerant R -410A

GLDC

0604

0704

0804

0904

1004

1104

1204

Cooling capacity

kW

151.6

171.9

194.8

221.7

244.0

281.3

312.2

Max. external pressure

Pa

390

280

320

400

310

270

300

El. power consumption

kW

62.5

73.1

83.5

89.6

101.6

115.0

133.2

EER

2.4

2.4

2.3

2.5

2.4

2.5

2.3

ESEER

3.7

3.6

3.5

3.9

3.8

3.8

3.6

Cooling capacity

kW

150.9

171.1

193.9

220.7

242.9

280.1

310.9

El. power consumption

Performance values according to


EN14511:2011

kW

57.9

68.2

76.9

83.5

95.1

108.6

125.0

EER

2.6

2.5

2.5

2.6

2.6

2.6

2.5

ESEER

3.7

3.6

3.5

3.8

3.6

3.7

3.6

Max. current consumption

139.0

156.0

181.0

201.0

220.0

246.0

282.0

Max. power consumption

kW

79.6

90.4

105.0

115.0

126.0

142.0

163.0

Scroll
compressor

Quantity

Refrigeration Circuits

Quantity

Capacity stages

Quantity

Sound power level

dB(A)

97

98

99

98

99

99

100

Sound pressure level

dB(A)

65

66

67

66

67

67

68

Length

mm

3602

3602

4602

4602

4602

4602

5602

Width

mm

1277

1277

1277

1277

1277

1277

1277

Height

mm

1900

1900

2235

2235

2235

2235

2235

kg

1845

1940

2310

2445

2515

2695

2885

Weight
Performance data
Sound power level
Sound pressure level

At chilled water 12/7C and air intake temperature 35C


EUROVENT certified figure, requirement specified by Eurovent 8/1 and ISO 9614
Rectangular-shaped radiation 10 m distance reflection factor Q=2
For project-related sound data calculations - use the obligatory sound power level!

PR-2014-0100-GB Subject to modifications K0-06/2014

x41]

Chiller inside installation air cooled


GLRC 2015 4160 CD2 41 kW to 442 kW

Equipment
Standard configuration with 2 or 4 scroll compressors
Condenser by others, air or water cooled
Pump module optional (hydraulics module GLPE)

additionally with safety valve, venting and filler connection


Device dimensions change when using the
pump module
Autoadaptive microprocessor control
Unit main switch
Controller type: HVAC Systems Step I (2015 ...2061)

HVAC Systems Step II (4060 ...4160)


Master/slave operation with GEA HVAC System unit series availa-

ble as an accessory item


Connection to BMS via optional interface

Refrigerant R -410A

GLRC

2015

2018

2020

2025

2026

2030

2035

2041

2045

2051

2055

2061

Cooling capacity

kW

40.6

46.9

55.0

62.1

69.0

82.1

95.1

107.2

120.3

134.7

154.4

174.2

El. power consumption

kW

11.5

12.9

15.0

17.3

19.1

22.5

25.8

29.1

32.6

36.1

41.5

47.0

EER

3.5

3.6

3.7

3.6

3.6

3.7

3.7

3.7

3.7

3.7

3.7

3.7

ESEER

Cooling capacity

kW

40.2

46.6

54.7

61.7

68.5

81.8

94.7

106.7

119.8

134.1

153.9

173.5

El. power consumption

kW

11.8

13.2

15.4

17.7

19.6

22.9

26.2

29.6

33.1

36.6

42.1

47.7

3.4

3.5

3.6

3.5

3.5

3.6

3.6

3.6

3.6

3.7

3.7

3.6

Performance values
as of EN14511:2011

EER
ESEER

Max. current consumption

30.6

32.8

40.8

45.2

51.0

61.0

66.6

72.2

81.9

91.6

104.7

117.8

Max. power consumption

kW

18.0

20.2

23.6

26.4

28.8

34.0

39.3

44.6

49.7

54.8

63.2

71.6

Scroll compressor

QTY

Refrigeration Circuits

QTY

Capacity stages

QTY

Sound power level

dB(A)

73

74

74

74

75

76

77

77

78

78

79

79

Sound pressure level

dB(A)

42

43

43

43

44

44

45

45

46

46

47

47

Length

mm

1130

1130

1130

1130

1130

1310

1310

1310

1310

1310

1310

1310

Width

mm

669

669

669

669

669

893

893

893

893

893

893

893

Height

mm

1255

1255

1255

1255

1255

1496

1496

1496

1496

1496

1496

1496

Weight

kg

270

280

290

295

300

410

500

585

615

645

680

700

Performance data
Sound power level
Sound pressure level

x42]

At chilled water 12/7C and condensing temperature 45C


Requirement specified by ISO 3744
Rectangular-shaped radiation 10 m distance reflection factor Q=2
For project-related sound data calculations - use the obligatory sound power level!

PR-2014-0100-GB Subject to modifications K0-06/2014

Chiller inside installation air cooled


GLRC 2015 4160 CD2 41 kW to 442 kW

Refrigerant R -410A

GLRC

4060

4070

4080

4090

4100

4110

4120

4140

4160

Cooling capacity

kW

164.7

190.2

212.7

241.4

269.6

308.0

347.7

396.1

442.2

El. power consumption

kW

45.0

51.6

58.1

65.2

72.2

83.1

93.9

106.6

119.3

EER

3.7

3.7

3.7

3.7

3.7

3.7

3.7

3.7

3.7

ESEER

Cooling capacity

kW

164.1

189.5

211.8

240.4

268.6

307.0

346.3

394.4

440.2

El. power consumption

kW

45.7

52.3

59.0

66.1

73.2

84.1

95.3

108.3

121.2

EER

3.6

3.6

3.6

3.6

3.7

3.7

3.6

3.6

3.6

ESEER

Max. current consumption

122.0

133.2

144.4

163.8

183.2

209.4

235.6

265.0

294.4

Max. power consumption

kW

68.0

78.6

89.0

99.0

110.0

126.0

143.0

164.6

186.0

Scroll
compressor

Quantity

Refrigeration Circuits

Quantity

Capacity stages

Quantity

Sound power level

dB(A)

86

87

88

89

90

91

91

91

91

Sound pressure level

Performance values according to EN14511:2011

dB(A)

54

55

56

57

58

59

59

59

59

Length

mm

2227

2227

2227

2227

2227

2227

2227

2227

2227

Width

mm

1020

1020

1020

1020

1020

1020

1020

1020

1020

Height

mm

1780

1780

1780

1780

1780

1780

1780

1780

1780

Weight

kg

755

950

1125

1185

1250

1330

1370

1430

1480

Performance data
Sound power level
Sound pressure level

At chilled water 12/7C and condensing temperature 45C


Requirement specified by ISO 3744
Rectangular-shaped radiation 10 m distance reflection factor Q=2
For project-related sound data calculations - use the obligatory sound power level!

PR-2014-0100-GB Subject to modifications K0-06/2014

x43]

Chiller inside installation water cooled


GLWC 0152 1204 BD2 43 kW to 371 kW

Equipment
Standard configuration with 2 or 4 scroll compressors
Pump module optional (hydraulics module GLPE/GLPC)

additionally with safety valve, expansion vessel,


pressure gauge, venting and filler connection
Device dimensions change when using the
pump module
Autoadaptive microprocessor control
Unit main switch

Controler type: HVAC Systems-Step I (0152 ... 0612)


HVAC Systems-Step II (0604 ... 1204)
Master/slave operation with GEA HVAC System unit series availa-

ble as an accessory item


Connection to BMS via optional interface

Refrigerant R -410A

GLWC

0152

0182

0202

0252

0262

0302

0352

0412

0452

0512

0552

0612

Cooling capacity

kW

43.4

50.1

59.0

66.4

72.6

86.7

101.2

114.7

128.6

143.5

164.9

186.3

El. power consumption

kW

10.0

11.3

13.0

15.2

16.6

19.5

22.7

25.9

28.9

32.2

36.9

41.6

EER

4.3

4.4

4.5

4.4

4.4

4.4

4.5

4.4

4.5

4.5

4.5

4.5

ESEER

5.8

6.0

6.0

5.7

5.6

5.7

5.8

5.7

5.8

5.8

5.9

5.8

Cooling capacity

kW

43.0

49.7

58.6

66.0

72.1

86.3

100.8

114.1

128.0

142.9

164.3

185.5

El. power consumption

Performance values
as of EN14511:2011

kW

10.7

12.0

13.9

16.1

17.7

20.4

23.6

27.1

30.2

33.5

38.3

43.3

EER

4.0

4.1

4.2

4.1

4.1

4.2

4.3

4.2

4.3

4.3

4.3

4.3

ESEER

5.0

5.2

5.2

5.0

4.9

5.1

5.2

5.2

5.2

5.3

5.4

5.3

Max. current consumption

30.6

32.8

40.8

45.2

51.0

55.8

64.0

72.2

81.9

91.6

104.7

117.8

Max. power consumption

kW

18.0

20.2

23.6

26.4

28.8

33.8

39.2

44.6

49.7

54.8

63.2

71.6

Scroll compressor

QTY

Refrigeration Circuits

QTY

Capacity stages

QTY

Sound power level

dB(A)

73

74

74

74

75

76

77

77

78

78

79

79

Sound pressure level

dB(A)

42

43

43

43

44

44

45

45

46

46

47

47

Length

mm

1055

1055

1055

1055

1055

1222

1222

1222

1222

1222

1222

1222

Width

mm

649

649

649

649

649

873

873

873

873

873

873

873

Height

mm

1255

1255

1255

1255

1255

1496

1496

1496

1496

1496

1496

1496

Weight

kg

285

300

310

320

325

570

610

640

680

725

770

800

Performance data
Sound power level
Sound pressure level

x44]

At chilled water 12/7C and cooling water temperature 30/35C


EUROVENT certified figure, requirement specified by Eurovent 8/1 and ISO 9614
Rectangular-shaped radiation 10 m distance reflection factor Q=2
For project-related sound data calculations - use the obligatory sound power level!

PR-2014-0100-GB Subject to modifications K0-06/2014

Chiller inside installation water cooled


GLWC 0152 1204 BD2 43 kW to 371 kW

Refrigerant R -410A

GLWC

0604

0704

0804

0904

1004

1104

1204

Cooling capacity

kW

173.9

202.7

228.0

257.9

288.1

328.5

371.1

El. power consumption

kW

38.9

45.2

51.6

58.0

64.1

74.0

83.5

EER

4.5

4.5

4.4

4.5

4.5

4.4

4.4

ESEER

5.8

5.9

5.8

5.9

5.9

6.0

5.9

Cooling capacity

kW

173.3

202.0

227.1

256.9

287.1

327.5

369.8

El. power consumption

kW

40.4

46.8

53.4

59.9

66.1

76.2

86.4

EER

4.3

4.3

4.3

4.3

4.3

4.3

4.3

ESEER

5.2

5.3

5.3

5.4

5.4

5.5

5.3

Max. current consumption

111.6

128.0

144.4

163.8

183.2

209.4

235.6

Max. power consumption

Performance values according


to EN14511:2011

kW

68.0

78.0

89.0

99.0

110.0

126.0

143.0

Scroll
compressor

Quantity

Refrigeration Circuits

Quantity

Capacity stages

Quantity

Sound power level

dB(A)

86

87

88

89

90

91

91

Sound pressure level

dB(A)

54

55

56

57

58

59

59

Length

mm

2227

2227

2227

2227

2227

2227

2227

Width

mm

877

877

877

877

877

877

877

Height

mm

1780

1780

1780

1780

1780

1780

1780

Weight

kg

1050

1125

1190

1270

1355

1445

1510

Performance data
Sound power level
Sound pressure level

At chilled water 12/7C and cooling water temperature 30/35C


EUROVENT certified figure, requirement specified by Eurovent 8/1 and ISO 9614
Rectangular-shaped radiation 10 m distance reflection factor Q=2
For project-related sound data calculations - use the obligatory sound power level!

PR-2014-0100-GB Subject to modifications K0-06/2014

x45]

Chiller inside installation water cooled


GLWC 0401 1902 BA2 87 kW to 447 kW

Equipment
Standard configuration with 1 or 2 screw compressors
Control cabinet on the long side
Pump control as an option
Autoadaptive microprocessor control
Unit main switch
Controller type: HVAC Systems Step III
Master/slave operation with GEA HVAC System unit series availa-

ble as an accessory item


Connection to BMS via optional interface

Refrigerant R-134a

GLWC

0401

0501

0551

0651

0751

0851

0951

Cooling capacity

kW

87.0

106.6

130.2

147.4

164.6

197.7

221.1

El. power consumption

kW

19.6

24.5

28.1

32.7

36.9

42.7

49.6

EER

4.4

4.4

4.6

4.5

4.5

4.6

4.5

ESEER

5.2

5.3

5.3

5.3

5.4

5.5

5.4

Cooling capacity

kW

86.7

106.4

129.9

147.0

164.1

197.2

220.2

El. power consumption

kW

20.3

25.5

29.1

33.9

38.2

44.4

51.4

4.3

4.2

4.5

4.3

4.3

4.5

4.3

Performance values according to


EN14511:2011

EER
ESEER

4.8

4.9

4.9

5.0

5.0

5.2

5.0

Max. current consumption

55.4

67.1

80.4

91.7

105.0

115.0

132.0

Max. power consumption

kW

32.6

40.5

48.7

51.7

64.3

70.2

82.1

Screw compressor

Quantity

Refrigeration Circuits

Quantity

Minimum partial load level

50

50

50

50

50

50

50

Sound power level

dB(A)

91

92

94

94

94

94

94

Sound pressure level

dB(A)

60

61

62

62

62

62

62

Length

mm

2300

2500

2500

2500

2500

3200

3200

Width

mm

1000

1000

1000

1000

1000

1000

1000

Height

mm

1500

1500

1500

1500

1500

1500

1500

Weight

kg

800

840

1160

1180

1190

1270

1350

Performance data
Sound power level
Sound pressure level

x46]

At chilled water 12/7C and cooling water temperature 30/35C


EUROVENT certified figure, requirement specified by Eurovent 8/1 and ISO 9614
Rectangular-shaped radiation 10 m distance reflection factor Q=2
For project-related sound data calculations - use the obligatory sound power level!

PR-2014-0100-GB Subject to modifications K0-06/2014

Chiller inside installation water cooled


GLWC 0401 1902 BA2 87 kW to 447 kW

Refrigerant R-134a

GLWC

0802

1002

1102

1302

1502

1702

1902

Cooling capacity

kW

177.5

217.0

250.7

297.9

340.1

392.9

447.0

El. power consumption

kW

39.3

49.2

55.8

65.6

74.5

85.4

99.5

EER

4.5

4.4

4.5

4.5

4.6

4.6

4.5

ESEER

5.4

5.5

5.2

5.5

5.7

5.7

5.6

Cooling capacity

kW

177.1

216.2

249.6

296.8

338.9

391.2

445.8

El. power consumption

kW

40.7

51.3

58.0

68.1

77.2

89.0

102.4

EER

4.4

4.2

4.3

4.4

4.4

4.4

4.4

ESEER

4.9

4.9

4.7

5.0

4.9

5.0

5.2

Max. current consumption

111.0

134.0

161.0

183.0

210.0

230.0

264.0

Performance values according to


EN14511:2011

Max. power consumption

kW

65.2

81.0

97.4

103.0

129.0

140.0

164.0

Screw compressor

Quantity

Refrigeration Circuits

Quantity

25

25

25

25

25

25

25

Sound power level

dB(A)

94

95

97

97

97

97

97

Sound pressure level

Minimum partial load level

dB(A)

62

63

65

65

65

65

65

Length

mm

3200

3200

3200

3500

3500

3500

3500

Width

mm

1200

1200

1200

1200

1200

1200

1200

Height

mm

1500

1500

1500

1800

1800

1800

1800

Weight

kg

1470

1490

1930

2220

2260

2320

2720

Performance data
Sound power level
Sound pressure level

At chilled water 12/7C and cooling water temperature 30/35C


EUROVENT certified figure, requirement specified by Eurovent 8/1 and ISO 9614
Rectangular-shaped radiation 10 m distance reflection factor Q=2
For project-related sound data calculations - use the obligatory sound power level!

PR-2014-0100-GB Subject to modifications K0-06/2014

x47]

Chiller inside installation water cooled


GLWC 1130 4960 CA2 / .HE 306 kW to 2416 kW

Equipment
Standard configuration with 1, 2, 3 or 4 screw compressors
HE configuration with 1 or 2 screw compressors
Control cabinet on the front side
Pump control as an option
Autoadaptive microprocessor control
Unit main switch
Configuration with an electronic expansion valve EEV
Controller type: HVAC Systems Step III
Master/slave operation with GEA HVAC System unit series availa-

ble as an accessory item


Connection to BMS via optional interface

Can be delivered in two different versions:


GLWC 1130 4960 CA2 as standard unit
GLWC 1130 2480 CA2.HE as highly efficient version

Refrigerant R-134a

GLWC

1130

1140

1160

1180

1210

1240

1270

2280

1300

2320

2360

2420

Cooling capacity

kW

306.0

348.3

421.9

477.4

537.7

606.8

674.9

694.1

746.4

843.9

957.3

1071.3

El. power consumption

kW

60.5

68.7

83.4

94.4

106.0

119.7

133.5

137.4

147.5

166.7

188.8

211.6

EER

5.1

5.1

5.1

5.1

5.1

5.1

5.1

5.1

5.1

5.1

5.1

5.1

ESEER

5.9

6.0

5.7

5.8

5.9

5.9

5.8

5.9

5.9

5.9

6.1

6.1

Cooling capacity

kW

304.9

347.0

420.1

475.8

535.9

604.3

672.7

691.6

743.5

841.1

954.1

1068.8

El. power consumption

kW

62.7

71.3

86.6

97.6

109.7

124.2

137.9

142.0

152.9

172.1

194.9

217.2

4.9

4.9

4.9

4.9

4.9

4.9

4.9

4.9

4.9

4.9

4.9

4.9

Performance values
as of EN14511:2011

EER
ESEER

5.4

5.5

5.3

5.4

5.5

5.4

5.4

5.4

5.4

5.4

5.6

5.7

Max. current consumption

147.0

168.0

197.0

223.0

247.0

286.0

318.0

336.0

351.0

394.0

446.0

494.0

Max. power consumption

kW

89.0

101.0

122.0

138.0

155.0

175.0

196.0

203.0

216.0

243.0

275.0

310.0

Screw compressor

QTY

Refrigeration Circuits

QTY

Minimum partial load


level

25

25

25

25

25

25

25

12.5

25

12.5

12.5

12.5

Sound power level

dB(A)

97

97

97

97

97

97

99

99

99

99

99

99

Sound pressure level

dB(A)

65

65

65

65

65

65

67

67

67

67

67

67

Length

mm

3830

3830

3860

3860

3860

3860

3930

4200

3930

4750

4750

4750

Width

mm

900

900

900

900

900

900

900

1150

900

1150

1150

1150

Height

mm

1700

1700

1840

1840

1840

1840

1990

2050

1990

2050

2050

2200

Weight

kg

2050

2110

2590

2810

2910

2970

3510

4120

3600

5110

5400

6070

Performance data
Sound power level
Sound pressure level

x48]

At chilled water 12/7C and cooling water temperature 30/35C


EUROVENT certified figure, requirement specified by Eurovent 8/1 and ISO 9614
Rectangular-shaped radiation 10 m distance reflection factor Q=2.
For project-related sound data calculations - use the obligatory sound power level!

PR-2014-0100-GB Subject to modifications K0-06/2014

Chiller inside installation water cooled


GLWC 1130 4960 CA2 / .HE 306 kW to 2416 kW
Refrigerant R-134a

GLWC

2450

2480

2540

2600

3630*

3660*

3720*

3780*

3810*

3900*

4900*

4960*

Cooling capacity

kW

1144.7

1213.3

1348.2

1490.3

1603.6

1676.6

1815.0

1967.0

2024.4

2235.5

2278.0

2416.1

El. power consumption

kW

226.1

239.8

266.9

295.0

317.4

331.3

359.1

388.9

400.4

442.0

450.7

478.2

EER

5.1

5.1

5.1

5.1

5.1

5.1

5.1

5.1

5.1

5.1

5.1

5.1

ESEER

6.2

6.2

6.0

6.1

6.1

6.2

6.2

6.1

6.1

6.1

6.2

6.2

Cooling capacity

kW

1141.8

1210.0

1343.9

1484.9

1599.4

1671.5

1808.8

1961.6

2018.6

2228.0

2273.1

2410.3

El. power consumption

kW

232.4

246.8

275.1

304.8

326.0

341.0

370.5

399.8

411.8

455.8

461.8

490.8

EER

4.9

4.9

4.9

4.9

4.9

4.9

4.9

4.9

4.9

4.9

4.9

4.9

ESEER

5.8

5.7

5.5

5.6

5.7

5.7

5.6

5.6

5.6

5.6

5.8

5.7

Max. current consumption

533.0

572.0

636.0

702.0

741.0

780.0

858.0

922.0

954.0

1053.0

1066.0

1144.0

Performance values according to EN14511:2011

Max. power consumption

kW

330.0

350.0

391.0

432.0

465.0

485.0

525.0

566.0

587.0

648.0

660.0

700.0

Screw compressor

Quantity

Refrigeration Circuits

Quantity

Minimum partial load level

12.5

12.5

12.5

12.5

8.5

8.5

8.5

8.5

8.5

8.5

6.25

6.25

Sound power level

dB(A)

99

99

101

101

102

102

102

102

102

102

102

102

Sound pressure level

dB(A)

67

67

69

69

70

70

70

70

70

70

70

70

Length

mm

4750

4750

4850

4850

4950

4950

4950

4950

4950

4950

4650

4650

Width

mm

1150

1150

1150

1150

1700

1700

1700

1700

1700

1700

2250

2250

Height

mm

2200

2200

2200

2200

2150

2150

2150

2150

2150

2150

2230

2230

Weight

kg

6120

6180

6950

7090

8980

9050

9120

9950

10170

10350

14330

14390

* These units are not certified by Eurovent

Refrigerant R-134a

GLWC.HE

1130

1140

1160

1180

1210

1240

2280

2320

2360

2420

2480

Cooling capacity

kW

320.7

364.7

441.9

506.4

573.7

649.4

729.5

884.2

1012.3

1146.9

1298.5

El. power consumption

kW

57.3

65.1

79.1

90.3

102.6

116.2

130.3

158.1

180.4

205.1

232.3

EER

5.6

5.6

5.6

5.6

5.6

5.6

5.6

5.6

5.6

5.6

5.6

ESEER

6.5

6.5

6.3

6.4

6.4

6.4

6.7

6.6

6.7

6.6

6.7

Cooling capacity

kW

319.4

363.3

440.0

504.3

571.4

646.6

726.7

880.5

1009.3

1142.6

1293.0

El. power consumption

kW

60.0

68.2

83.0

94.7

107.6

122.1

136.0

165.5

187.7

214.4

243.5

5.3

5.3

5.3

5.3

5.3

5.3

5.3

5.3

5.4

5.3

5.3

Performance values according to EN14511:2011

EER
ESEER

5.8

5.8

5.7

5.7

5.7

5.7

6.0

5.8

6.1

5.9

5.9

Max. current consumption

146.8

168.0

197.2

223.0

247.0

286.0

336.0

394.4

446.0

494.0

572.0

Max. power consumption

kW

89.0

101.3

121.6

137.7

154.9

175.1

202.6

243.2

275.4

309.8

350.2

Screw compressor

Quantity

Refrigeration Circuits

Quantity

25

25

25

25

25

25

25

25

25

25

25

Sound power level

dB(A)

97

97

97

97

97

97

99

99

99

99

99

Sound pressure level

dB(A)

65

65

65

65

65

65

67

67

67

67

67

Length

mm

4250

4250

4150

4150

4130

4350

4550

4950

5170

4920

4920

Width

mm

900

900

900

900

900

900

1150

1150

1150

1150

1285

Height

mm

1815

1910

1990

1990

1990

2090

2050

2200

2200

2350

2430

Weight

kg

2470

2770

3570

3750

3790

4230

5390

6460

6920

7900

8560

Minimum partial load level

Performance data
Sound power level
Sound pressure level

At chilled water 12/7C and cooling water temperature 30/35C


EUROVENT certified figure, requirement specified by Eurovent 8/1 and ISO 9614
Rectangular-shaped radiation 10 m distance reflection factor Q=2
For project-related sound data calculations - use the obligatory sound power level!

PR-2014-0100-GB Subject to modifications K0-06/2014

x49]

Heat pump outside installation air-cooled


GSAH 0011 ...0061 FD5 / FD1 5.7 kW to 16.8 kW

Equipment
Optimized packaged model with 1 scroll compressor
Self-supporting sheet steel construction

- galvanized
- powder-coated
Heat-pump cycle with a 4-way valve
Standard pump module integrated

additionally fitted with safety valve, expansion tank, pressure


gauge, air vent and fill connection
Following pump heads for pipework provided on-site
Second pump for increasing pump head as an option for model

sizes 0041 - 0061


Buffer tank to be mounted below the unit is available as an option

Can be delivered in two different versions:


GSAH 0011 ...0041 FD5 with 230 V supply voltage

Cooling operation down to -10 C air inlet temperature

GSAH 0011 ...0061 FD1 with 400 V supply voltage

Heating operation down to -7 C air inlet temperature


Condensing pressure is used to regulate fan speed
Autoadaptive microprocessor control

Supply voltage

Refrigerant R-410a

1~230 Volt (Series FD5)

GSAC

0011

0021

0025

Heating capacity

kW

5.7

6.5

Max. power consumption

kW

2.3

2.4

Cooling capacity

kW

4.6

ESEER

Max. current consumption

3~400 Volt (Series FD1)

0031

0041

0021

0025

0031

0041

0051

0061

8.1

10

12.4

2.9

3.6

4.5

6.4

9.7

12.8

14.4

16.8

2.4

2.7

3.2

4.7

5.0

5.4

5.4

6.6

8.2

10.4

5.3

6.7

8.2

10.8

12.6

14.6

3.0

3.2

3.2

3.0

3.0

3.2

3.4

3.2

3.1

3.1

3.3

17.6

17.6

20.6

24.6

28.6

7.1

7.6

9.6

11.6

13.4

16.6

Scroll
compressor

Quantity

Refrigeration Circuits

Quantity

Capacity stages

Quantity

Delivery head of remaining pipework

kPa

59.0

57.0

54.0

54.0

43.0

57.0

54.0

54.0

40.0

33.0

30.0

Rated volume flow

m/h

0.8

1.0

1.2

1.5

1.9

1.0

1.2

1.5

2.0

2.3

2.7

Sound power level

dB(A)

65

66

66

66

69

66

66

66

69

69

69

Sound pressure level

dB(A)

37

38

38

38

41

38

38

38

41

41

41

Length

mm

900

900

900

900

900

900

900

900

900

900

900

Width

mm

370

370

370

370

370

370

370

370

370

370

420

Height

mm

640

640

940

940

1240

640

940

940

1240

1240

1390

Weight

kg

90

95

110

115

140

95

110

115

140

160

170

Performance data
Sound power level
Sound pressure level

x50]

At chilled water 40/45C and air intake temperature 7C


At chilled water 12/7C and air intake temperature 35C * in heating mode
EUROVENT certified figure, requirement specified by Eurovent 8/1 and ISO 9614
Rectangular-shaped radiation 10 m distance reflection factor Q=2
For project-related sound data calculations - use the obligatory sound power level!

PR-2014-0100-GB Subject to modifications K0-06/2014

Heat pump outside installation air-cooled


GAH(N,P) 016 064 FD1 20 kW to 75 kW

Equipment
Space-saving optimized version with 1 or 2 DC inverters

Scroll compressors
Heat-pump cycle with a 4-way valve
Cooling operation von -15 C bis +43 C air inlet temperature

Heating operation von -15 C bis +35 C air outlet temperature


Microprocessor control
Automatic self-diagnostics
Integrated 24h real-time clock with indication of weekdays
Inverter-controlled condenser fans
Pressure sensor for high and low pressure
Electronic Expansion Valve (EEV)

Can be delivered in two different versions:

Installed water filter


Shut-off valves for water inlet and outlet are supplied separately

GAHN - without hydraulic unit

Flow switch mounted and cabled in the unit

GAHP - with pump module, manometer, safety valve, expan-

Noise-reduced operation possible

sion vessel

Leading/following operation of several units with accessories

GZSEQUENC.E18 is possible
Connection to the building management system with Modbus Pro-

tocol with accessory GZAMODBUS.E14 is possible


Additional controller functions, see page 69

Refrigerant R-410a

GAH_*

016

021

025

032

040

050

064

Heating capacity

kW

20.0

25.0

30.0

37.5

50.0

60.0

75.0

Max. power consumption

kW

9.6

9.0

11.7

13.1

18.0

23.5

26.1

Cooling capacity

kW

20.0

25.0

30.0

37.5

50.0

60.0

75.0

ESEER

4.8

4.7

4.5

4.0

4.6

4.4

4.0

Max. current consumption

22.0

25.0

26.0

35.0

47.0

50.0

67.0

Scroll
compressor

Quantity

Refrigeration Circuits

Quantity

Capacity stages

Quantity

Sound power level

dB(A)

78

78

78

80

81

81

83

Sound pressure level

dB(A)

46

46

48

46

49

49

51

Length

mm

1371

1371

1371

1684

2358

2358

2980

Width

mm

774

774

774

774

780

780

780

Height

mm

1684

1684

1684

1684

1684

1684

1684

*Weight GAHN - without pump

kg

267

320

320

401

577

577

738

*Weight GAHP - with pump

kg

282

335

335

415

610

610

771

Performance data
Sound power level
Sound pressure level

At chilled water 40/45C and air intake temperature 7C


At chilled water 12/7C and air intake temperature 35C * in heating mode
EUROVENT certified figure, requirement specified by Eurovent 8/1 and ISO 9614
Rectangular-shaped radiation 10 m distance reflection factor Q=2
For project-related sound data calculations - use the obligatory sound power level!

PR-2014-0100-GB Subject to modifications K0-06/2014

x51]

Heat pump outside installation air-cooled


GLAH 0152 0612 BD1 / .LT 42 kW to 174 kW
Equipment
Standard- and LT version with 2 scroll compressors
Heat-pump cycle with a 4-way valve
Buffer tank and pump optional (hydraulics module GLHM)

In addition, with flow switch, regulating valve, safety valve, expansion vessel, venting and filler connection
Cooling operation down to -15 C ambient temperature

Heating operation down to -5 C ambient temperature,


Heating operation down to -10 C ambient temperature with LT model
Installed water filter
Autoadaptive microprocessor control
Controller type: HVAC Systems Step I

Can be delivered in two different versions:

Unit main switch


Master/slave operation with GEA HVAC System unit series availa-

GLAH 0152 0612 BD1 as standard unit


GLAH 0152 0512 BD1.LT as quiet version and extended tem-

ble as an accessory item


Connection to BMS via optional interface

Refrigerant R -410A

perature range for heat pump operation

GLAH

0152

0182

0202

0252

0302

0352

0412

0452

0512

0552

0612

Cooling capacity

kW

37.7

42.8

47.9

57.5

72.1

82.5

93.9

106.7

120.1

137.6

150.5

El. cooling power consumption

kW

13.6

15.7

19.2

20.4

28.0

32.0

36.0

39.8

44.0

50.4

59.0

EER

2.8

2.7

2.5

2.8

2.6

2.6

2.6

2.7

2.7

2.7

2.6

ESEER

4.0

4.1

4.0

4.0

4.0

4.1

3.9

4.1

4.0

4.2

4.0

Cooling capacity

kW

37.4

42.5

47.6

57.2

71.6

82.0

93.3

106.0

119.4

136.7

149.6

El. power consumption

kW

13.9

16.0

19.5

20.8

28.5

32.5

36.6

40.5

44.7

51.3

59.9

EER

2.7

2.7

2.4

2.8

2.5

2.5

2.6

2.6

2.7

2.7

2.5

ESEER

3.8

3.8

3.8

3.8

3.7

3.9

3.7

3.9

3.8

4.0

3.8

Heating capacity

kW

42.9

48.1

54.2

65.2

81.0

93.5

105.4

120.7

135.7

156.5

172.5

El. heat power consumption

kW

14.2

15.6

18.1

21.2

26.1

29.8

33.9

37.9

42.3

48.4

54.4

3.0

3.1

3.0

3.1

3.1

3.1

3.1

3.2

3.2

3.2

3.2

Heating capacity

kW

43.3

48.5

54.6

65.6

81.7

94.2

106.2

121.5

136.7

157.8

174.0

El. power consumption

kW

14.7

16.0

18.5

21.7

26.7

30.5

34.7

38.7

43.3

49.6

55.8

Perform. factors EN14511:2011

COP
Perform. factors (EN14511:2011)

COP

3.0

3.0

3.0

3.0

3.1

3.1

3.1

3.1

3.2

3.2

3.1

Max. current consumption

35.0

37.0

45.0

52.0

62.0

71.0

81.0

91.0

103.0

116.0

129.0

Max. power consumption

kW

19.0

21.2

24.6

27.9

35.3

40.7

46.6

51.7

57.3

65.7

74.1

Scroll compressor

Quantity

Refrigeration Circuits

Quantity

Capacity stages

Quantity

Sound power level

dB(A)

84

84

84

84

85

86

86

86

87

87

87

Sound pressure level

dB(A)

52

52

52

52

53

54

54

54

55

55

55

Length

mm

1695

1695

1695

2195

2195

2195

2745

2745

3245

3245

3245

Width

mm

1120

1120

1120

1120

1120

1120

1120

1120

1120

1120

1120

Height

mm

1420

1420

1420

1420

1420

1420

1420

1420

1620

1620

1620

kg

450

460

470

560

690

750

840

910

1030

1090

1100

Weight
Performance data
Sound power level
Sound pressure level

x52]

At chilled water 40/45C and air intake temperature 7C


At chilled water 12/7C and air intake temperature 35C * in heating mode
EUROVENT certified figure, requirement specified by Eurovent 8/1 and ISO 9614
Rectangular-shaped radiation 10 m distance reflection factor Q=2
For project-related sound data calculations - use the obligatory sound power level!

PR-2014-0100-GB Subject to modifications K0-06/2014

Heat pump outside installation air-cooled


GLAH 0152 0612 BD1 / .LT 42 kW to 174 kW

Refrigerant R -410A

GLAH.LT

0152

0182

0202

0252

0302

0352

0412

0452

0512

Cooling capacity

kW

35.8

41.6

48.0

54.6

73.2

83.5

93.9

103.2

118.9

El. cooling power consumption

kW

14.3

16.0

19.1

21.4

27.2

31.9

36.0

41.6

44.6

EER

2.5

2.6

2.5

2.6

2.7

2.6

2.6

2.5

2.7

ESEER

4.1

4.2

4.0

4.0

4.1

4.0

3.9

3.9

4.0

Cooling capacity

kW

35.5

41.3

47.7

54.3

72.7

83.0

93.3

102.6

118.2

El. power consumption

kW

14.6

16.3

19.4

21.7

27.7

32.5

36.6

42.2

45.3

EER

2.4

2.5

2.5

2.5

2.6

2.6

2.6

2.4

2.6

ESEER

3.8

3.9

3.8

3.9

3.9

3.8

3.8

3.8

3.8

Heating capacity

kW

41.8

48.2

54.1

63.6

84.1

96.2

108.9

120.6

137.5

El. heat power consumption

kW

13.8

15.2

18.1

20.6

26.1

30.4

34.1

37.9

42.4

3.0

3.2

3.0

3.1

3.2

3.2

3.2

3.2

3.2

Heating capacity

kW

42.2

48.6

54.5

64.0

84.7

96.9

109.8

121.5

138.5

El. power consumption

kW

14.2

15.6

18.5

21.1

26.7

31.2

34.9

38.7

43.4

3.0

3.1

3.0

3.0

3.2

3.1

3.1

3.1

3.2

Max. current consumption

33.0

36.0

45.0

49.0

61.0

73.0

81.0

91.0

103.0

Max. power consumption

kW

18.6

20.8

24.6

27.4

35.1

41.2

46.6

51.7

57.3

Scroll
compressor

Quantity

Refrigeration Circuits

Quantity

Capacity stages

Quantity

Sound power level

dB(A)

79

79

80

80

81

83

83

83

84

Sound pressure level

Performance values according to


EN14511:2011

COP
Performance values according to
EN14511:2011

COP

dB(A)

48

48

49

49

49

51

51

51

52

Length

mm

1695

1695

2195

2195

2745

2745

2745

2745

3245

Width

mm

1120

1120

1120

1120

1120

1120

1120

1120

1120

Height

mm

1420

1420

1420

1420

1420

1620

1620

1620

1620

Weight

kg

450

480

520

560

770

840

910

950

1070

Performance data
Sound power level
Sound pressure level

Version .LT with cooling operation to -15 C, heating operation to -10 C outdoor temperature
For warm water 40/45 C and air intake temperature 7 C
At chilled water 12/7C and air intake temperature 35C * in heating mode
EUROVENT certified figure, requirement specified by Eurovent 8/1 and ISO 9614
Rectangular-shaped radiation 10 m distance reflection factor Q=2
For project-related sound data calculations - use the obligatory sound power level!

PR-2014-0100-GB Subject to modifications K0-06/2014

x53]

Heat pump outside installation air-cooled


GLAH 0524 1204 BD2 / .LT 147 kW to 359 kW
Equipment
Standard- and LT version with 4 scroll compressors
Heat-pump cycle with a 4-way valve
Buffer tank and pump are optional (hydraulic module GLHM) addi-

tionally fitted with a regulating valve, safety valve, expansion tank,


air vent and fill connection
Cooling operation down to -15 C ambient temperature

Heating operation down to -5 C ambient temperature,


Heating operation down to -10 C ambient temperature with LT model
Installed water filter
Autoadaptive microprocessor control
Controller type: HVAC Systems Step II
Unit main switch

Can be delivered in two different versions:

Master/slave operation with GEA HVAC System unit series availa-

GLAH 0524 1204 BD2 as standard unit

ble as an accessory item

GLAH 0524 1204 BD2.LT with extended range of applica-

Connection to BMS via optional interface

Refrigerant R -410A

tion for heat pump operation

GLAH

0524

0604

0704

0804

0904

1004

1104

1204

Cooling capacity

kW

129.1

146.8

165.9

188.8

211.0

240.0

277.1

310.8

El. cooling power consumption

kW

54.0

59.9

68.9

75.8

85.2

95.6

107.4

120.5

EER

2.4

2.5

2.4

2.5

2.5

2.5

2.6

2.6

ESEER

3.4

3.6

3.6

3.8

3.9

3.7

3.8

3.9

Cooling capacity

kW

128.3

145.9

164.9

187.7

209.7

238.4

275.7

309.2

El. power consumption

kW

54.8

60.9

69.9

76.9

86.5

97.3

108.8

122.0

EER

2.3

2.4

2.4

2.4

2.4

2.5

2.5

2.5

ESEER

3.2

3.4

3.5

3.6

3.6

3.5

3.7

3.8

Heating capacity

kW

145.4

166.9

185.1

209.3

234.2

266.5

306.4

343.9

El. heat power consumption

kW

52.8

57.9

64.8

72.1

79.8

92.0

104.1

116.3

2.8

2.9

2.9

2.9

2.9

2.9

2.9

3.0

Heating capacity

kW

146.5

168.3

186.3

210.8

235.9

268.7

308.1

346.0

El. power consumption

kW

53.8

59.2

66.1

73.6

81.5

94.2

105.9

118.4

Performance values EN14511:2011

COP
Performance values EN14511:2011

COP

2.7

2.8

2.8

2.9

2.9

2.9

2.9

2.9

Max. current consumption

116.0

132.0

156.0

174.0

197.0

228.0

241.0

254.0

Max. power consumption

kW

70.0

77.0

91.0

104.0

116.0

133.0

143.0

154.0

Scroll compressor

Quantity

Refrigeration Circuits

Quantity

Capacity stages

Quantity

Sound power level

dB(A)

92

92

92

92

93

94

95

95

Sound pressure level

dB(A)

60

60

60

60

61

62

63

63

Length

mm

3110

3110

3110

3110

4110

4110

4110

4110

Width

mm

2220

2220

2220

2220

2220

2220

2220

2220

Height

mm

1700

1700

2150

2150

2150

2150

2150

2150

Weight

kg

1570

1750

1900

2080

2270

2410

2540

2700

Performance data
Sound power level
Sound pressure level

x54]

At chilled water 40/45C and air intake temperature 7C


At chilled water 12/7C and air intake temperature 35C * in heating mode
EUROVENT certified figure, requirement specified by Eurovent 8/1 and ISO 9614
Rectangular-shaped radiation 10 m distance reflection factor Q=2
For project-related sound data calculations - use the obligatory sound power level!

PR-2014-0100-GB Subject to modifications K0-06/2014

Heat pump outside installation air-cooled


GLAH 0524 1204 BD2 / .LT 147 kW to 359 kW

Refrigerant R -410A

GLAH.LT

0524

0604

0704

0804

0904

1004

1104

1204

Cooling capacity

kW

134.1

149.3

171.9

197.9

219.4

248.1

286.5

322.1

El. cooling power consumption

kW

51.3

58.6

65.7

75.3

85.2

91.7

102.8

119.0

EER

2.6

2.6

2.6

2.6

2.6

2.7

2.8

2.7

ESEER

3.5

3.6

3.8

3.6

3.6

3.8

4.0

3.8

Cooling capacity

kW

133.2

148.3

170.9

196.6

217.9

246.4

285.0

320.5

El. power consumption

Performance values according to


EN14511:2011

kW

52.2

59.5

66.7

76.6

86.7

93.4

104.2

120.7

EER

2.6

2.5

2.6

2.6

2.5

2.6

2.7

2.7

ESEER

3.3

3.4

3.6

3.4

3.4

3.6

3.7

3.7

Heating capacity

kW

149.8

166.5

190.6

219.7

243.5

273.8

315.4

356.5

El. heat power consumption

kW

53.0

57.8

65.1

76.9

84.5

92.3

104.5

121.0

2.8

2.9

2.9

2.9

2.9

3.0

3.0

3.0

Heating capacity

kW

150.9

167.8

192.0

221.4

245.5

276.2

317.4

358.7

El. power consumption

123.3

COP
Performance values EN14511:2011

kW

54.1

59.2

66.5

78.6

86.4

94.7

106.4

COP

2.8

2.8

2.9

2.8

2.8

2.9

3.0

2.9

Max. current consumption

116.0

132.0

156.0

182.0

205.0

228.0

241.0

262.0

Max. power consumption

kW

70.0

77.0

91.0

108.0

120.0

133.0

143.0

158.0

Scroll compressor

Quantity

Refrigeration Circuits

Quantity

Capacity stages

Quantity

Sound power level

dB(A)

92

92

92

94

94

94

96

97

Sound pressure level

dB(A)

60

60

60

62

62

62

64

65

Length

mm

3110

3110

3110

4110

4110

4110

5110

5110

Width

mm

2220

2220

2220

2220

2220

2220

2220

2220

Height

mm

2150

2150

2150

2150

2150

2150

2150

2150

Weight

kg

1700

1840

1980

2310

2370

2520

2800

2940

Performance data
Sound power level
Sound pressure level

Version .LT with cooling operation to -15 C, heating operation to -10 C outdoor temperature
At chilled water 40/45C and air intake temperature 7C
At chilled water 12/7C and air intake temperature 35C * in heating mode
EUROVENT certified figure, requirement specified by Eurovent 8/1 and ISO 9614
Rectangular-shaped radiation 10 m distance reflection factor Q=2
For project-related sound data calculations - use the obligatory sound power level!

PR-2014-0100-GB Subject to modifications K0-06/2014

x55]

Heat pump outside installation air-cooled


GLAH 4131 ...8321 CD2 / .LT 373 kW to 902 kW
Equipment
High-efficiency optimized version with 4, 6 or 8 scroll compressors
Heat-pump cycle with a 4-way valve
Buffer tank and pump are optional (hydraulic module GLHM) addi-

tionally fitted with a safety valve, expansion tank, air vent and fill
connection
Cooling operation down to -15 C ambient temperature
Heating operation down to -5 C ambient temperature,
Heating operation down to -12 C ambient temperature with LT
model
Autoadaptive microprocessor control
Controller type: HVAC Systems Step II
Unit main switch
Configuration with an electronic expansion valve EEV
Master/slave operation with GEA HVAC System unit series available as an accessory item
Connection to BMS via optional interface

Refrigerant R -410A

Can be delivered in two different versions:


GLAH 4131 8321 CD2 as standard unit
GLAH 4131 8321 CD2.LT with extended range of application
for heat pump operation

GLAH

4131

4141

4161

6171

6181

6201

6211

6241

8241

8261

8281

8301

8321

Cooling capacity

kW

339.4

363.4

396.4

434.9

477.8

525.7

546.2

594.3

637.7

678.0

728.4

760.9

792.4

El. cooling power consumption

kW

126.4

132.0

151.4

164.6

177.8

190.4

198.1

227.1

237.1

252.7

264.2

283.2

302.8

EER

2.7

2.8

2.6

2.6

2.7

2.8

2.8

2.6

2.7

2.7

2.8

2.7

2.6

ESEER

3.8

3.9

3.8

3.9

3.8

3.9

3.9

3.8

3.8

3.8

3.9

3.9

3.8

Cooling capacity

kW

338.0

362.1

394.7

433.6

476.1

524.0

544.4

592.3

635.5

675.5

726.2

758.5

789.7

El. power consumption

kW

127.8

133.3

153.1

165.9

179.4

192.1

199.9

229.1

239.3

255.2

266.3

285.6

305.5

EER

2.7

2.7

2.6

2.6

2.7

2.7

2.7

2.6

2.7

2.7

2.7

2.7

2.6

ESEER

3.6

3.7

3.6

3.8

3.6

3.8

3.8

3.6

3.8

3.8

3.9

3.9

3.8

Heating capacity

kW

371.0

398.0

435.7

472.9

514.6

572.2

597.2

653.6

686.2

742.0

796.3

834.3

871.4

El. heat power consumption

kW

122.4

129.7

142.8

157.2

170.6

187.2

194.1

214.3

227.2

245.2

258.7

272.3

285.6

3.0

3.1

3.1

3.0

3.0

3.1

3.1

3.1

3.0

3.0

3.1

3.1

3.1

Heating capacity

kW

372.8

399.7

437.9

474.5

516.6

574.3

599.6

656.2

688.9

745.3

799.1

837.4

875.0

El. power consumption

kW

124.2

131.4

144.9

158.9

172.7

189.3

196.4

216.9

229.9

248.5

261.6

275.4

289.2

Performance factors (EN14511:2011)

COP
Performance factors (EN14511:2011)

COP

3.0

3.0

3.0

3.0

3.0

3.0

3.1

3.0

3.0

3.0

3.1

3.0

3.0

Max. current consumption

273.1

287.8

317.2

353.8

387.6

417.0

431.7

475.8

516.8

546.2

575.6

605.0

634.4

Max. power consumption

kW

165.9

176.6

198.0

212.0

232.8

254.2

264.9

297.0

310.4

331.8

353.2

374.6

396.0

Scroll compressor

QTY

Refrigeration Circuits

QTY

Capacity stages

QTY

Sound power level

dB(A)

96

96

96

96

97

97

97

98

98

98

99

99

99

Sound pressure level

dB(A)

64

64

64

64

65

65

65

66

65

65

66

66

66

Length

mm

3905

3905

3905

4515

5690

5690

5690

5690

7430

7430

7430

7430

7430

Width

mm

2260

2260

2260

2260

2260

2260

2260

2260

2260

2260

2260

2260

2260

Height

mm

2450

2450

2450

2450

2450

2450

2450

2450

2450

2450

2450

2450

2450

kg

3170

3250

3280

4220

4610

4740

4810

4860

5950

6080

6230

6260

6300

Weight
Performance data
Sound power level
Sound pressure level

x56]

For warm water 40/45 C and air intake temperature 7 C / For cold water 12/7 C and air intake temperature 35 C; * in heating operation
EUROVENT certified figure, requirement specified by Eurovent 8/1 and ISO 9614
Rectangular-shaped radiation 10 m distance reflection factor Q=2
For project-related sound data calculations - use the obligatory sound power level!

PR-2014-0100-GB Subject to modifications K0-06/2014

Heat pump outside installation air-cooled


GLAH 4131 ...8321 CD2 / .LT 373 kW to 902 kW

Refrigerant R -410A

GLAH.LT 4131

4141

4161

6171

6181

6201

6211

6241

8241

8261

8281

8301

8321

Cooling capacity

kW

351.8

371.8

416.8

453.2

504.4

537.6

559.0

624.8

666.7

709.6

745.4

789.3

833.2

El. cooling power consumption

kW

121.2

127.8

143.4

155.5

172.6

184.7

191.7

215.0

228.2

242.3

255.7

269.9

286.7

EER

2.9

2.9

2.9

2.9

2.9

2.9

2.9

2.9

2.9

2.9

2.9

2.9

2.9

ESEER

4.1

4.2

4.1

4.2

4.1

4.2

4.2

4.1

4.1

4.1

4.2

4.2

4.1

Cooling capacity

kW

350.2

370.4

414.9

451.8

502.5

535.9

557.0

622.6

664.3

706.7

743.1

786.6

830.1

El. power consumption

kW

122.7

129.2

145.2

156.9

174.5

186.5

193.7

217.3

230.7

245.1

258.0

272.5

289.8

EER

2.9

2.9

2.9

2.9

2.9

2.9

2.9

2.9

2.9

2.9

2.9

2.9

2.9

ESEER

3.9

4.0

3.9

4.0

3.9

4.0

4.0

4.1

4.1

4.1

4.2

4.2

4.1

Heating capacity

kW

383.2

409.4

449.2

496.7

533.2

586.5

614.1

673.6

708.5

766.4

818.9

860.0

898.4

El. heat power consumption

kW

119.5

127.8

139.8

154.8

166.2

182.6

191.2

209.9

221.3

239.4

254.9

268.7

279.8

3.2

3.2

3.2

3.2

3.2

3.2

3.2

3.2

3.2

3.2

3.2

3.2

3.2

Heating capacity

kW

385.1

411.2

451.5

498.6

535.4

588.7

616.7

676.4

711.4

770.0

821.9

863.4

902.2

El. power consumption

kW

121.5

129.7

142.2

156.6

168.4

184.9

193.8

212.7

224.3

243.0

258.0

272.1

283.6

Performance factors (EN14511:2011)

COP
Performance factors (EN14511:2011)

COP

3.2

3.2

3.2

3.2

3.2

3.2

3.2

3.2

3.2

3.2

3.2

3.2

3.2

Max. current consumption

280.7

295.4

324.8

365.2

399.0

428.4

443.1

487.2

532.0

561.4

590.8

620.2

649.6

Max. power consumption

kW

169.9

180.6

202.0

218.0

238.8

260.2

270.9

303.0

318.4

339.8

361.2

382.6

404.0

Scroll compressor

Quantity

Refrigeration Circuits

Quantity

Capacity stages

Quantity

Sound power level

dB(A)

97

97

97

97

98

98

98

99

99

99

100

100

100

Sound pressure level

dB(A)

65

65

65

64

65

65

65

66

66

66

67

67

67

Length

mm

5080

5080

5080

6255

7430

7430

7430

7430

9780

9780

9780

9780

9780

Width

mm

2260

2260

2260

2260

2260

2260

2260

2260

2260

2260

2260

2260

2260

Height

mm

2450

2450

2450

2450

2450

2450

2450

2450

2450

2450

2450

2450

2450

Weight

kg

3490

3580

3610

4840

5120

5270

5350

5400

6610

6760

6940

6970

7000

Performance data
Sound power level
Sound pressure level

For warm water 40/45 C and air intake temperature 7 C / For cold water 12/7 C and air intake temperature 35 C; * in heating operation
EUROVENT certified figure, requirement specified by Eurovent 8/1 and ISO 9614
Rectangular-shaped radiation 10 m distance reflection factor Q=2
For project-related sound data calculations - use the obligatory sound power level!

PR-2014-0100-GB Subject to modifications K0-06/2014

x57]

Heat pump outside installation air-cooled


GCH 100 250 CD4 / CD1 13 kW to 32 kW

Equipment
Space-saving optimized version (1 or 2 scroll compressors)
Heat-pump cycle with a 4-way valve
Inverter technology is used for compressor control
Cooling operation from 43 C to -5 C outside temperature (dry bulb)
Heating operation from 15.5 C to -20 C outdoor temperature (wet bulb)
Control over constant evaporation and condensing temperatures or

via 0-10 volt signal provided on-site

Accessories required
Expansion valve kit GZCHCD.R12
Communication box GZCH-CBOX.E13 or
GZCH-DBOX.E12 with GZCH-010V.E11

Supply voltage

1~230 Volt (Series CD4)

Refrigerant R -410A

3~400 Volt (Series CD1)

GCH

100

125

140

125

200

250

Heating capacity

kW

12.5

16.0

18.0

16.0

25.0

31.5

Max. power consumption

kW

2.7

3.9

4.6

4.0

5.6

7.7

Cooling capacity

kW

11.2

14.0

15.5

14.0

22.4

28.0

Max. power consumption

kW

2.8

3.5

4.5

3.5

5.2

7.4

Max. current consumption

kW

27.0

27.0

27.0

16.0

17.0

32.0

Scroll compressor

Quantity

Refrigeration Circuits

Quantity

24-100

24-100

24-100

50-100

50-100

50-100

Sound power level

dB(A)

66

67

69

72

78

78

Sound pressure level

Capacity stages

dB(A)

38

39

41

44

50

50

Length

mm

900

900

900

635

635

635

Width

mm

320

320

320

76

765

765

Height

mm

1345

1345

1345

1680

1680

1680

Weight

kg

120

120

120

157

185

238

Accessories: overview of expansion valves


GZCH###CD.R12

063

080

100

125

140

200

250

Cooling capacity
min.

kW

6.3

7.9

10.0

12.4

15.5

17.7

24.7

max.

kW

7.8

9.9

12.3

15.4

17.6

24.6

30.8

min.

dm

0.96

1.22

1.53

1.91

2.14

3.06

3.82

max.

dm

1.22

1.53

1.91

2.14

2.97

3.8

4.78

of capacity stage

100

100

100

100

125

200

200

up to capacity stage

125

140

200

250

250

250

250

Evaporation volume

can be combined with:

Length

mm

401

401

401

401

401

401

401

Width

mm

215

215

215

215

215

215

215

Height

mm

78

78

78

78

78

78

78

kg

2.9

2.9

2.9

2.9

2.9

2.9

2.9

Operating weight
Performance data
Sound power level
Sound pressure level

x58]

Cooling - at evaporating temperature 7C and outside-air temperature 35C / heating - at condensation temperature 45C and outside-air temperature 7C
Determination according to ISO 3744
Cube-shaped radiaton 10 m distance reflection factor Q=2
For project-related sound data calculations - use the obligatory sound power level!

PR-2014-0100-GB Subject to modifications K0-06/2014

Heat pump inside installation air-cooled


GSDH 0011 ...0061 FD5 / FD1 5.7 kW to 16.8 kW

Equipment
Optimized packaged model with 1 scroll compressor
Heat-pump cycle with a 4-way valve
Standard pump module integrated

additionally fitted with safety valve, expansion tank, pressure


gauge, air vent and fill connection
Following pump heads for pipework provided on-site
Second pump to enlarge the delivery head

as option for model sizes 0041 ... 0061


Buffer tank to be mounted below the unit is available as an option
Cooling operation down to -10 C air inlet temperature

Heating operation down to -7 C air inlet temperature

Can be delivered in two different versions:

Condensing pressure is used to regulate fan speed


Centrifugal fan for pressure-side duct connection

GSDH 0011 ...0041 FD5 with 230 V supply voltage

Autoadaptive microprocessor control

GSDH 0021 ...0061 FD1 with 400 V supply voltage

Supply voltage

Refrigerant R -410A

1~230 Volt (Series FD5)

3~400 Volt (Series FD1)

GSDH

0011

0021

0025

0031

0041

0021

0025

0031

0041

0051

0061

Heating capacity

kW

5.7

6.5

8.1

10

12.4

6.4

9.7

12.8

14.4

16.8

Max. power consumption

kW

2.3

2.4

2.9

3.6

4.5

2.4

2.7

3.2

4.7

5.4

Cooling capacity

kW

4.6

5.4

6.6

8.2

10.4

5.3

6.7

8.2

10.8

12.6

14.6

max. external pressure

Pa

200.0

100.0

200.0

80.0

80.0

100.0

200.0

80.0

80.0

80.0

70.0

ESEER

2.1

2.4

2.5

2.5

2.3

2.4

2.6

2.6

2.4

2.4

2.6

Max. current consumption

20.3

30.3

23.3

27.3

31.3

9.8

10.3

12.3

14.3

16.1

19.3

Scroll compressor

QTY

Refrigeration Circuits

QTY

Capacity stages

QTY

Delivery head of remaining pipework

kPa

59.0

57.0

54.0

54.0

43.0

57.0

54.0

54.0

40.0

33.0

30.0

Rated volume flow

m/h

0.8

1.0

1.2

1.5

1.9

1.0

1.2

1.5

2.0

2.3

2.7

Sound power level

dB(A)

68

68

68

68

71

68

68

68

71

71

71

Sound pressure level

dB(A)

40

40

40

40

43

40

40

40

43

43

43

Length

mm

900

900

900

900

900

900

900

900

900

900

900

Width

mm

580

580

580

580

580

580

580

580

580

580

630

Height

mm

640

640

940

940

1240

640

940

940

1240

1240

1390

Weight

kg

110

115

130

135

180

115

130

135

180

200

210

Performance data
Sound power level
Sound pressure level

At warm water 40/45C and air intake temperature 7C


At chilled water 12/7C and air inlet temperature 35C *in heating mode
EUROVENT certified figure, requirement specified by Eurovent 8/1 and ISO 9614
Rectangular-shaped radiation 10 m distance reflection factor Q=2
For project-related sound data calculations - use the obligatory sound power level!

PR-2014-0100-GB Subject to modifications K0-06/2014

x59]

Heat pump inside installation water-cooled


GLWH 0152 1204 BD2 50 kW to 419 kW

Equipment
Standard configuration with 2 scroll compressors
Heat-pump cycle with a 4-way valve
Pump module optional (hydraulics module GLPE/GLPC)

additionally with safety valve, expansion vessel,


pressure gauge, venting and filler connection
different device dimensions when using the pump module
Autoadaptive microprocessor control
Unit main switch
Controller type: HVAC Systems Step I (0152 ...0612)

HVAC Systems Step II (0604 ...1204)


Master/slave operation with GEA HVAC System unit series availa-

ble as an accessory item


Connection to BMS via optional interface

Refrigerant R -410A

GLWH

0152

0182

0202

0252

0262

0302

0352

0412

452

512

552

612

Cooling capacity

kW

43.4

50.1

59.0

66.4

72.6

86.7

101.2

114.7

128.6

143.5

164.9

186.3

El. cooling power consumption

kW

10.2

11.5

13.3

15.5

17.0

19.9

23.1

26.4

29.5

32.8

37.6

42.5

EER

4.3

4.3

4.4

4.3

4.3

4.4

4.4

4.3

4.4

4.4

4.4

4.4

ESEER

5.7

5.9

5.9

5.6

5.5

5.5

5.7

5.6

5.7

5.7

5.8

5.7

Cooling capacity

kW

43.1

49.9

58.7

66.1

72.2

86.3

100.9

114.3

128.1

143.0

164.4

185.7

El. power consumption

Performance factors EN14511:2011

kW

10.7

12.1

14.0

16.4

18.0

20.7

24.0

27.4

30.8

34.0

39.0

44.0

EER

4.0

4.1

4.2

4.0

4.0

4.2

4.2

4.2

4.2

4.2

4.2

4.2

ESEER

5.1

5.2

5.2

4.9

4.8

5.1

5.2

5.2

5.2

5.2

5.3

5.3

Heating capacity

kW

49.2

56.7

66.2

75.1

82.9

98.3

113.8

128.5

144.4

161.1

185.1

209.0

El. heat power consumption

kW

12.9

14.3

16.7

19.2

21.0

24.6

28.3

32.1

35.8

39.8

45.6

51.5

3.8

4.0

4.0

3.9

4.0

4.0

4.0

4.0

4.0

4.1

4.1

4.1

Heating capacity

kW

49.5

57.0

66.6

75.5

83.5

98.7

114.3

129.0

145.0

161.8

185.7

209.8

El. power consumption

53.0

COP
Performance factor EN14511:2011

kW

13.4

14.9

17.4

20.0

22.1

25.4

29.1

33.0

37.0

41.0

46.9

COP

3.7

3.8

3.8

3.8

3.8

3.9

3.9

3.9

3.9

4.0

4.0

4.0

Max. current consumption

30.6

32.8

40.8

45.2

51.0

55.8

64.0

72.2

81.9

91.6

104.7

117.8

Max. power consumption

kW

18.0

20.2

23.6

26.4

28.8

33.8

39.2

44.6

49.7

54.8

63.2

71.6

Scroll compressor

Quantity

Refrigeration Circuits

Quantity

Capacity stages

Quantity

Sound power level

dB(A)

73

74

74

74

75

76

77

77

78

78

79

79

Sound pressure level

dB(A)

42

43

43

43

44

44

45

45

46

46

47

47

Length

mm

1055

1055

1055.0

1055

1055

1222

1222

1222

1222

1222

1222

1222

Width

mm

649

649

649.0

649

649

873

873

873

873

873

873

873

Height

mm

1255

1255

1255.0

1255

1255

1496

1496

1496

1496

1496

1496

1496

Weight

kg

300

315

325.0

335

340

595

630

675

705

755

805

850

Performance data
Sound power level
Sound pressure level

x60]

Cooling - At chilled water 12/7C and cooling water 30/35C


Heating - At warm water 40/45 C and chilled water 10/6 C
EUROVENT certified figure, requirement specified by Eurovent 8/1 and ISO 9614
Rectangular-shaped radiation 10 m distance reflection factor Q=2
For project-related sound data calculations - use the obligatory sound power level!

PR-2014-0100-GB Subject to modifications K0-06/2014

Heat pump inside installation water-cooled


GLWH 0152 1204 BD2 50 kW to 419 kW

Refrigerant R -410A

GLWH

0604

0704

0804

0904

1004

1104

1204

Cooling capacity

kW

173.9

202.7

228.0

257.9

288.1

328.5

371.1

El. cooling power consumption

kW

39.7

46.1

52.6

59.1

65.3

75.4

85.2

EER

4.4

4.4

4.3

4.4

4.4

4.4

4.4

ESEER

5.7

5.8

5.7

5.8

5.8

5.9

5.8

Cooling capacity

kW

173.4

202.1

227.3

257.1

287.4

327.7

370.2

El. power consumption

kW

41.0

47.6

54.1

61.2

67.3

77.6

87.7

EER

4.2

4.3

4.2

4.2

4.3

4.2

4.2

ESEER

5.2

5.3

5.3

5.2

5.3

5.4

5.3

Heating capacity

kW

197.1

227.7

255.7

289.3

322.9

369.2

417.0

El. heat power consumption

kW

49.0

56.4

63.8

71.7

79.2

91.5

103.4

4.0

4.0

4.0

4.0

4.1

4.0

4.0

Heating capacity

kW

197.8

228.5

256.5

290.3

323.9

370.3

418.3

El. power consumption

kW

50.3

57.8

65.3

73.7

81.1

93.6

105.8

Performance values as of EN14511:2011

COP
Performance values as of EN14511:2011

COP

3.9

4.0

3.9

3.9

4.0

4.0

4.0

Max. current consumption

111.6

128.0

144.4

163.8

183.2

209.4

235.6

Max. power consumption

kW

68.0

78.0

89.0

99.0

110.0

126.0

143.0

Scroll compressor

Quantity

Refrigeration Circuits

Quantity

Capacity stages

Quantity

Sound power level

dB(A)

86

87

88

89

90

91

91

Sound pressure level

dB(A)

54

55

56

57

58

59

59

Length

mm

2227

2227

2227

2227

2227

2227

2227

Width

mm

877

877

877

877

877

877

877

Height

mm

1780

1780

1780

1780

1780

1780

1780

Weight

kg

1100

1175

1255

1310

1415

1520

1600

Performance data
Sound power level
Sound pressure level

Cooling - At chilled water 12/7C and cooling water 30/35C


Heating - At warm water 40/45 C and chilled water 10/6 C
EUROVENT certified figure, requirement specified by Eurovent 8/1 and ISO 9614
Rectangular-shaped radiation 10 m distance reflection factor Q=2
For project-related sound data calculations - use the obligatory sound power level!

PR-2014-0100-GB Subject to modifications K0-06/2014

x61]

Heat pump inside installation water-cooled


GLWH 0401 1902 BA2 97 kW to 494 kW

Equipment
Standard configuration with 1 or 2 screw compressors
Control cabinet on the long side
Pump control as an option
Selectable regulation of condenser water temperature (warm water)

and evaporator water temperature (chilled water)


Autoadaptive microprocessor control
Unit main switch
Controller type: HVAC Systems Step III
Master/slave operation with GEA HVAC System unit series availa-

ble as an accessory item


Connection to BMS via optional interface

Refrigerant R-134a

GLWH

0401

0501

0551

0651

0751

0851

0951

Cooling capacity

kW

86.96

106.64

130.23

147.36

164.58

197.72

221.11

El. cooling power consumption

kW

19.58

24.49

28.12

32.7

36.89

42.74

49.61

EER

4.4

4.4

4.6

4.5

4.5

4.6

4.5

ESEER

5.2

5.3

5.3

5.3

5.4

5.5

5.4

Cooling capacity

kW

86.7

106.4

129.9

147.0

164.1

197.2

220.2

El. power consumption

kW

20.3

25.5

29.1

33.9

38.2

44.4

51.4

EER

4.3

4.2

4.5

4.3

4.3

4.5

4.3

ESEER

4.8

4.9

4.9

5.0

5.0

5.2

5.0

Heating capacity

kW

96.5

119.0

143.0

162.8

182.9

216.5

244.5

El. heat power consumption

kW

23.3

29.0

33.9

38.9

43.6

50.8

58.5

4.1

4.1

4.2

4.2

4.2

4.3

4.2

Heating capacity

kW

96.8

119.6

143.6

163.5

183.6

217.4

245.3

El. power consumption

kW

24.0

29.9

34.8

40.0

44.9

52.3

60.3

Performance values as of EN14511:2011

COP
Performance values as of EN14511:2011

COP

4.0

4.0

4.1

4.1

4.1

4.2

4.1

Max. current consumption

55.4

67.1

80.4

91.7

105.0

115.0

132.0

Max. power consumption

kW

32.6

40.5

48.7

51.7

64.3

70.2

82.1

Screw compressor

Quantity

Refrigeration Circuits

Quantity

50

50

50

50

50

50

50

Sound power level

dB(A)

91

92

94

94

94

94

94

Sound pressure level

dB(A)

60

61

62

62

62

62

62

Length

mm

2300

2500

2500

2500

2500

3200

3200

Width

mm

1000

1000

1000

1000

1000

1000

1000

Height

mm

1500

1500

1500

1500

1500

1500

1500

Weight

kg

800

840

1160

1180

1190

1270

1350

Minimum partial load level

Performance data
Sound power level
Sound pressure level

x62]

Cooling - At chilled water 12/7C and cooling water 30/35C


Heating - At warm water 40/45 C and chilled water 10/6 C
EUROVENT certified figure, requirement specified by Eurovent 8/1 and ISO 9614 Eurovent 8/1 and ISO 9614
Rectangular-shaped radiation 10 m distance reflection factor Q=2
For project-related sound data calculations - use the obligatory sound power level!

PR-2014-0100-GB Subject to modifications K0-06/2014

Heat pump inside installation water-cooled


GLWH 0401 1902 BA2 97 kW to 494 kW

Refrigerant R-134a

GLWH

0802

1002

1102

1302

1502

1702

1902

Cooling capacity

kW

177.52

217

250.72

297.94

340.11

392.94

446.98

El. cooling power consumption

kW

39.33

49.2

55.79

65.56

74.45

85.35

99.52

EER

4.5

4.4

4.5

4.5

4.6

4.6

4.5

ESEER

5.4

5.5

5.2

5.5

5.7

5.7

5.6

Cooling capacity

kW

177.1

216.2

249.6

296.8

338.9

391.2

445.8

El. power consumption

kW

40.7

51.3

58.0

68.1

77.2

89.0

102.4

EER

4.4

4.2

4.3

4.4

4.4

4.4

4.4

ESEER

4.9

4.9

4.7

5.0

4.9

5.0

5.2

Heating capacity

kW

195.9

241.1

278.0

328.3

374.9

430.9

493.0

El. heat power consumption

kW

46.8

58.1

67.3

78.0

87.8

101.5

117.2

4.2

4.2

4.1

4.2

4.3

4.3

4.2

Heating capacity

kW

196.7

242.1

278.9

329.4

376.1

432.5

494.3

El. power consumption

kW

48.1

60.1

69.6

80.4

90.5

105.0

119.9

Performance values as of EN14511:2011

COP
Performance values as of EN14511:2011

COP

4.1

4.0

4.0

4.1

4.2

4.1

4.1

Max. current consumption

111.0

134.0

161.0

183.0

210.0

230.0

264.0

Max. power consumption

kW

65.2

81.0

97.4

103.0

129.0

140.0

164.0

Screw compressor

Quantity

Refrigeration Circuits

Quantity

Minimum partial load level

25

25

25

25

25

25

25

Sound power level

dB(A)

94

95

97

97

97

97

97

Sound pressure level

dB(A)

62

63

65

65

65

65

65

Length

mm

3200

3200

3200

3500

3500

3500

3500

Width

mm

1200

1200

1200

1200

1200

1200

1200

Height

mm

1500

1500

1500

1800

1800

1800

1800

Weight

kg

1470

1490

1930

2220

2260

2320

2720

Performance data
Sound power level
Sound pressure level

Cooling - At chilled water 12/7C and cooling water 30/35C


Heating - At warm water 40/45 C and chilled water 10/6 C
EUROVENT certified figure, requirement specified by Eurovent 8/1 and ISO 9614 Eurovent 8/1 and ISO 9614
Rectangular-shaped radiation 10 m distance reflection factor Q=2
For project-related sound data calculations - use the obligatory sound power level!

PR-2014-0100-GB Subject to modifications K0-06/2014

x63]

Heat pump inside installation water-cooled


GLWH 1130 ...4960 CA2 339 kW to 2663 kW

Equipment
Standard configuration with 1, 2, 3 or 4 screw compressors
Control cabinet on the front side
Pump control as an option
Selectable regulation of condenser water temperature (warm water)

and evaporator water temperature (chilled water)


Autoadaptive microprocessor control
Unit main switch
Configuration with an electronic expansion valve EEV
Controller type: HVAC Systems Step III
Master/slave operation with GEA HVAC System unit series availa-

ble as an accessory item


Connection to BMS via optional interface

Refrigerant R-134a

GLWH

1130

1140

1160

1180

1210

1240

1270

2280

1300

2320

2360

2420

Cooling capacity

kW

306.04

348.34

421.85

477.38

537.72

606.81

674.9

694.08

746.42

843.86

957.31

1071.29

El. cooling power consumption

kW

60.47

68.7

83.36

94.38

106.02

119.66

133.47

137.4

147.52

166.71

188.78

211.62

EER

5.1

5.1

5.1

5.1

5.1

5.1

5.1

5.1

5.1

5.1

5.1

5.1

ESEER

5.9

6.0

5.7

5.8

5.9

5.9

5.8

5.9

5.9

5.9

6.1

6.1

Cooling capacity

kW

304.9

347.0

420.1

475.8

535.9

604.3

672.7

691.6

743.5

841.1

954.1

1068.8

El. power consumption

kW

62.7

71.3

86.6

97.6

109.7

124.2

137.9

142.0

152.9

172.1

194.9

217.2

EER

4.9

4.9

4.9

4.9

4.9

4.9

4.9

4.9

4.9

4.9

4.9

4.9

ESEER

5.4

5.5

5.3

5.4

5.5

5.4

5.4

5.4

5.4

5.4

5.6

5.7

Heating capacity

kW

337.8

384.3

459.6

520.3

589.9

666.6

736.1

766.4

814.3

919.3

1042.7

1177.1

El. heat power consumption

kW

76.6

87.0

103.8

117.7

132.0

148.9

164.6

174.1

181.7

207.7

235.4

263.6

4.4

4.4

4.4

4.4

4.5

4.5

4.5

4.4

4.5

4.4

4.4

4.5

Heating capacity

kW

338.7

385.4

460.8

521.6

591.4

668.3

737.9

768.2

816.3

921.4

1045.1

1179.8

El. power consumption

kW

78.9

89.7

107.1

120.9

135.7

153.7

169.1

178.9

187.3

213.1

241.5

269.2

Performance factors (EN14511:2011)

COP
Performance factors (EN14511:2011)

COP

4.3

4.3

4.3

4.3

4.4

4.4

4.4

4.3

4.4

4.3

4.3

4.4

Max. current consumption

147.0

168.0

197.0

223.0

247.0

286.0

318.0

336.0

351.0

394.0

446.0

494.0

Max. power consumption

kW

89.0

101.0

122.0

138.0

155.0

175.0

196.0

203.0

216.0

243.0

275.0

310.0

Screw compressor

QTY

Refrigeration Circuits

QTY

Minimum partial load level

25

25

25

25

25

25

25

12.5

25

12.5

12.5

12.5

Sound power level

dB(A)

97

97

97

97

97

97

99

99

99

99

99

99

Sound pressure level

dB(A)

65

65

65

65

65

65

67

67

67

67

67

67

Length

mm

3830

3830

3860

3860

3860

3860

3930

4200

3930

4750

4750

4750

Width

mm

900

900

900

900

900

900

900

1150

900

1150

1150

1150

Height

mm

1700

1700

1840

1840

1840

1840

1990

2050

1990

2050

2050

2200

Weight

kg

2050

2110

2590

2810

2910

2970

3510

4120

3600

5110

5400

6070

Performance data
Sound power level
Sound pressure level

x64]

Cooling - At chilled water 12/7C and cooling water 30/35C


Heating - At warm water 40/45 C and chilled water 10/6 C
EUROVENT certified figure, requirement specified by Eurovent 8/1 and ISO 9614 Eurovent 8/1 and ISO 9614
Rectangular-shaped radiation 10 m distance reflection factor Q=2
For project-related sound data calculations - use the obligatory sound power level!

PR-2014-0100-GB Subject to modifications K0-06/2014

Heat pump inside installation water-cooled


GLWH 1130 ...4960 CA2 339 kW to 2663 kW

Refrigerant R-134a

GLWH

2450

2480

2540

2600

3630* 3660* 3720* 3780*

3810*

3900*

4900*

4960*

Cooling capacity

kW

1144.7

1213.3

1348.2

1490.3

1603.6

1676.6

1815.0

1967.0

2024.4

2235.5

2278.0

2416.1

El. cooling power consumption

kW

226.1

239.8

266.9

295.0

317.4

331.3

359.1

388.9

400.4

442.0

450.7

478.2

EER

5.1

5.1

5.1

5.1

5.1

5.1

5.1

5.1

5.1

5.1

5.1

5.1

ESEER

6.2

6.2

6.0

6.1

6.1

6.2

6.2

6.1

6.1

6.1

6.2

6.2

Cooling capacity

kW

1141.8

1210.0

1343.9

1484.9

1599.4

1671.5

1808.8

1961.6

2018.6

2228.0

2273.1

2410.3

El. power consumption

kW

232.4

246.8

275.1

304.8

326.0

341.0

370.5

399.8

411.8

455.8

461.8

490.8

EER

4.9

4.9

4.9

4.9

4.9

4.9

4.9

4.9

4.9

4.9

4.9

4.9

ESEER

5.8

5.7

5.5

5.6

5.7

5.7

5.6

5.6

5.6

5.6

5.8

5.7

Heating capacity

kW

1256.1

1332.0

1470.9

1626.5

1762.8

1841.4

1995.0

2148.6

2207.9

2440.7

2504.8

2657.7

El. heat power consumption

kW

280.9

298.3

329.1

363.4

395.3

412.0

446.8

480.5

493.8

544.7

560.4

595.3

4.5

4.5

4.5

4.5

4.5

4.5

4.5

4.5

4.5

4.5

4.5

4.5

Heating capacity

kW

1258.9

1335.0

1474.1

1630.1

1766.5

1845.3

1999.3

2153.1

2212.4

2445.7

2509.9

2663.4

El. power consumption

kW

287.3

305.4

337.6

373.6

404.2

422.1

458.8

491.6

505.3

558.9

571.7

608.0

Performance factors
(EN14511:2011)

COP
Performance factors
(EN14511:2011)

COP

4.4

4.4

4.4

4.4

4.4

4.4

4.4

4.4

4.4

4.4

4.4

4.4

Max. current consumption

533.0

572.0

636.0

702.0

741.0

780.0

858.0

922.0

954.0

1053.0

1066.0

1144.0

Max. power consumption

kW

330.0

350.0

391.0

432.0

465.0

485.0

525.0

566.0

587.0

648.0

660.0

700.0

Screw compressor

Quantity

Refrigeration Circuits

Quantity

25

25

25

25

8.5

8.5

8.5

8.5

8.5

8.5

6.25

6.25

Sound power level

dB(A)

99

99

101

101

102

102

102

102

102

102

102

102

Sound pressure level

dB(A)

67

67

69

69

70

70

70

70

70

70

70

70

Length

mm

4750

4750

4850

4850

4950

4950

4950

4950

4950

4950

4650

4650

Width

mm

1150

1150

1150

1150

1700

1700

1700

1700

1700

1700

2250

2250

Height

mm

2200

2200

2200

2200

2150

2150

2150

2150

2150

2150

2230

2230

Weight

kg

6120

6180

6950

7090

8980

9050

9120.0

9950

10170

10350

14330

14390

Minimum partial load level

* These units are not certified by Eurovent


Performance data
Sound power level
Sound pressure level

Cooling - At chilled water 12/7C and cooling water 30/35C


Heating - At warm water 40/45 C and chilled water 10/6 C
EUROVENT certified figure, requirement specified by Eurovent 8/1 and ISO 9614 Eurovent 8/1 and ISO 9614
Rectangular-shaped radiation 10 m distance reflection factor Q=2
For project-related sound data calculations - use the obligatory sound power level!

PR-2014-0100-GB Subject to modifications K0-06/2014

x65]

Heat pump inside installation water-cooled


GLWH 1130 ...4960 CA2.HT 345 kW to 2581 kW

Equipment
HT version with 1, 2, 3 or 4 screw compressors
Extended operating limits
Control cabinet on the front side
Pump control as an option
Selectable regulation of condenser water temperature (warm water)

and evaporator water temperature (chilled water)


Autoadaptive microprocessor control
Unit main switch
Configuration with an electronic expansion valve EEV
Controller type: HVAC Systems Step III
Master/slave operation with GEA HVAC System unit series availa-

ble as an accessory item


Connection to BMS via optional interface

Refrigerant R-134a

GLWH.HT

1130

1140

1160

1180

1210

1240

2280

2320

2360

Cooling capacity

kW

315.9

357.6

418.9

478.9

533.6

585.0

712.5

838.0

960.4

El. cooling power consumption

kW

65.1

73.9

84.5

97.0

112.6

122.5

147.9

169.1

194.1

4.9

4.8

5.0

4.9

4.7

4.8

4.8

5.0

5.0

Cooling capacity

kW

314.7

356.2

417.2

477.3

531.8

582.7

709.9

835.2

957.1

El. power consumption

kW

67.5

76.7

87.7

100.3

116.2

126.8

152.9

174.4

200.3

4.7

4.7

4.8

4.8

4.6

4.6

4.6

4.8

4.8

Heating capacity

kW

343.8

393.1

454.1

526.0

588.1

646.0

783.8

908.3

1054.2

El. heat power consumption

kW

76.8

88.2

100.5

118.3

134.0

146.4

176.5

201.1

236.6

4.5

4.5

4.5

4.5

4.4

4.4

4.4

4.5

4.5

Heating capacity

kW

344.8

394.2

455.2

527.4

589.5

647.6

785.8

910.4

1056.6

El. power consumption

kW

79.2

91.1

103.7

121.6

137.7

150.8

181.6

206.4

242.9

EER
Performance factors
(EN14511:2011)

EER

COP
Performance factors
(EN14511:2011)

COP

4.4

4.3

4.4

4.3

4.3

4.3

4.3

4.4

4.4

Max. current consumption

214.0

245.0

274.0

314.0

358.0

390.0

490.0

548.0

628.0

Max. power consumption

kW

131.0

150.0

168.0

193.0

220.0

242.0

300.0

335.0

386.0

Screw compressor

Quantity

Refrigeration Circuits

Quantity

25

25

25

25

25

25

12.5

12.5

12.5

Sound power level

dB(A)

97

97

97

97

97

97

99

99

99

Sound pressure level

dB(A)

65

65

65

65

65

65

67

67

67

Length

mm

3830

3830

3860

3860

3860

3860

4200

4750

4750

Width

mm

900

900

900

900

900

900

1150

1150

1150

Height

mm

1700

1700

1840

1840

1840

1840

2050

2050

2050

Weight

kg

2050

2110

2590

2810

2910

2970

4120

5110

5400

Minimum partial load level

Performance data
Sound power level
Sound pressure level

x66]

Cooling - At chilled water 12/7C and cooling water 30/35C


Heating - At warm water 40/45 C and chilled water 10/6 C
Requirement specified by ISO 3744
Rectangular-shaped radiation 10 m distance reflection factor Q=2
For project-related sound data calculations - use the obligatory sound power level!

PR-2014-0100-GB Subject to modifications K0-06/2014

Heat pump inside installation water-cooled


GLWH 1130 ...4960 CA2.HT 345 kW to 2581 kW

Refrigerant R-134a

GLWH.HT

2420

2450

2480

3630*

3660*

3720

4900

4960

Cooling capacity

kW

1063.3

1118.3

1169.0

1591.6

1646.4

1749.6

2226.7

2329.7

El. cooling power consumption

kW

224.3

235.8

245.9

336.4

347.4

367.8

469.1

489.4

4.7

4.7

4.8

4.7

4.7

4.8

4.8

4.8

Cooling capacity

kW

1060.9

1115.6

1166.0

1587.5

1641.6

1744.0

2222.1

2324.5

El. power consumption

kW

229.9

241.9

252.4

345.0

356.8

378.3

479.8

501.0

EER
Performance factors
(EN14511:2011)

EER

4.6

4.6

4.6

4.6

4.6

4.6

4.6

4.6

Heating capacity

kW

1173.2

1233.8

1290.6

1757.0

1817.3

1933.2

2460.1

2575.5

El. heat power consumption

kW

267.1

280.8

293.7

400.6

413.6

439.4

559.0

584.9

4.4

4.4

4.4

4.4

4.4

4.4

4.4

4.4

Heating capacity

kW

1175.8

1236.5

1293.4

1760.6

1821.1

1937.2

2465.0

2580.8

El. power consumption

596.6

COP
Performance factors
(EN14511:2011)

kW

272.6

286.8

300.2

409.3

423.3

450.4

569.6

COP

4.3

4.3

4.3

4.3

4.3

4.3

4.3

4.3

Max. current consumption

716.0

748.0

780.0

1074.0

1106.0

1170.0

1496.0

1560.0

Max. power consumption

kW

440.0

462.0

484.0

660.0

682.0

726.0

924.0

968.0

Screw compressor

Quantity

Refrigeration Circuits

Quantity

12.5

12.5

12.5

8.5

8.5

8.5

6.25

6.25

Sound power level

dB(A)

99

99

99

102

102

102

102

102

Sound pressure level

Minimum partial load level

dB(A)

67

67

67

70

70

70

70

70

Length

mm

4750

4750

4750

4950

4950

4950

4650

4650

Width

mm

1150

1150

1150

1700

1700

1700

2250

2250

Height

mm

2200

2200

2200

2150

2150

2150

2230

2230

Weight

kg

6070

6120

6180

8980

9050

9120

14330

14390

* These units are not certified by Eurovent


Performance data
Cooling - At chilled water 12/7C and cooling water 30/35C
Heating - At warm water 40/45 C and chilled water 10/6 C
Sound power level
Requirement specified by ISO 3744
Sound pressure level
Rectangular-shaped radiation 10 m distance reflection factor Q=2
For project-related sound data calculations - use the obligatory sound power level!

PR-2014-0100-GB Subject to modifications K0-06/2014

x67]

Hydraulic module for inside and outside installation


GLHM#03# ... #25#-00 Buffer Volume 300 l to 2500 l

Equipment
External buffer tank module to be selected with chillers for safe operation and ensuring minimum run time.
Self-supporting construction using galvanized plastic coated metal sheet
Configuration with 1 to 2 pumps
Single circuit tank with 300 to 2500 l volume
Fitted with:

Expansion tank
Safety valve
Pressure gauge
Water-side differential pressure switch
Fill and drain valve

Depending on water volume and pressure drop, these mod-

Air vent valve

ules can be combined with the following chiller series, for

Thermal insulation using closed porous neoprene

which integrated hydraulic units are not available:


GLFC
GLAC / GLAH
GLWC / GLWH
GLRC

Module

GLHM

103#

203#

105#

205#

107#

207#

110#

210#

115#

215#

125#

225#

Volume

300

300

500

500

700

700

1000

1000

1500

1500

2500

2500

Pumps

Length

mm

1504

1504

1504

1504

2044

2044

2044

2044

2260

2260

2260

2260

Width

mm

1120

1120

1120

1120

1200

1200

1200

1200

1900

1900

1900

1900

Height

mm

1265

1265

1265

1265

1510

1510

1510

1510

1145

1145

1145

1145

kg

500

530

720

760

1130

1250

1430

1580

2130

2320

3190

3380

Operating weight

Example of system integration


Chiller
heat pump

x68]

GLHM ### #-00

Consumer

PR-2014-0100-GB Subject to modifications K0-06/2014

Control system
Features of chiller controller of G and GL series
HVAC Systems-Step I
Following controller functions are available as standard:

Alphanumeric displays
Selection between 3 languages
Remote ON/OFF contact
Collective fault message
Remote switch between heating/cooling mode
Actuation of the on-site pump
P-I temperature control at inlet and outlet
Retrieving last 200 alarm messages with alarm history

Additional controller functions are available as option:

Setpoint shift via 4-20 mA signal


Demand limit contact
Fault shutdown provided on-site
Connection to a remote control
Compressor soft start
Operation message of compressor
Connection to a BMS
Master/slave operation with up to 5 units

HVAC Systems-Step II
Following controller functions are available as standard:
As with HVAC systems step I, but with the following additional functions:

Setpoint shift via 4-20 mA signal


Selection between 7 languages
Fault shutdown provided on-site
Besides, the following additional controller functions are optional:
As with HVAC systems step I, but with the following additional functions:

2nd setpoint
HVAC Systems-Step III
Following controller functions are available as standard:
As with HVAC systems step I, but with the following additional functions:

Continuous capacity control of screw compressors


Selection between 7 languages
Without chilled water pump control
Besides, the following additional controller functions are optional:
As with HVAC systems step I, but with the following additional functions:

2nd setpoint
Regulation of chilled water pump
Controller of the GAC / GAH(N/P) 016 - 064 FD1 series
Following controller functions are available as standard:

Collective fault message


Run status unit
Actuation of the on-site pump
Chilled water outlet regulation or room temperature regulation
Reading off fault messages
Integrated timer-program for week management
Activation of noise-reduced operation with the remote control
Weather dependent setpoint (only GAH)
Night operation mode (only GAH)

Additional controller functions are available as option:

Connection of an additional remote control


Connection to a Building Management System
Master/slave operation with several units

PR-2014-0100-GB Subject to modifications K0-06/2014

x69]

GLAC2015-2070CD1/2.SL

GLAC2015-2081CD1/2.HE

E06

E14

Serial Card for LonWorks

E15

Serial interface card for BACnet over IP

E16

Serial interface card for BACnet MS/TP (RS485)

E17

Sequencer, master-slave controller

E18

External control panel for up to 200 m

E19

External control panel 200 up to 500 m

E20

Input for 4-20 mA setpoint displacement

E21

Input remote signal for second set point

E22

Input for capacity limitation

E23

Sequencer with serial interface card Carel/Modbus (RS485)

E24

Sequencer with serial interface card for LonWorks

E25

Sequencer with serial interface card for BACnet MS/TP (RS485)

E27

Compressor soft start

E28

Additional interface for extended controller functions

E29

Remote control

E30

Main switch

E31

Speed control for fan motors

E32

Remote control with comfort function

E33

Pump enabling for 2 evaporator pumps (1x Standby)

E34

Pump enabling for 1 evaporator and 1 condenser pump

E35

Pump enabling for 2 evaporator and 2 condenser pumps (each 1x Standby)

E36

0-10 volt output signal for high-pressure regulation provided on-site

E37

Modulating capacity control of compressors up to 25%

E38

Speed control for operation at low ambient temperatures

E39

Speed control down to -5 C discharge temperature

E40

Inverter regulated fans for operation to -10 C discharge temperature

E41

Extended fan control down to -5 C discharge temperature

E42

Inverter regulated fans for operation to -10 C discharge temperature

E43

Extended fan control down to -5 C discharge temperature

E44

Inverter regulated fans for operation to -10 C discharge temperature

E45

Compensation of reactive current for compressor

E46

Speed control for operation at low ambient temperatures or medium discharge temperatures

E47

Extended speed control for operation at very low ambient temperatures or very low medium discharge temperatures

E48, E49, E50

EC-Fans

E51, E52, E53

Extended range of application up to 50 C outdoor temperature

E54

Compensation of reactive current for compressor

E55, E56, E57

Heating for switch box

E58

Extended fan control down to -5 C discharge temperature

E62, E63, E64

Inverter regulated fans for operation down to -10 C discharge temperature & low Discharge Temperature

E65, E66, E67

Description
Accessories code

GAC/H(N,P)016-064FD1

GLAC2015-2070CD1/2

GS(A,D/C,H)0011-0061FD5/FD1

Overview of accessories

Electrical accessories
Additional remote control

E01

Compressor operation message

E03

Pump enabling

E04

Heavy-duty evaporator anti-freeze heating

E05

Soft start for compressors


Serial Card for Carel/Modbus (RS485)

Installation of accessories
Spring anti-vibration mounts

I01

Rubber anti-vibration isolators

I02, M03, I26, M10, I59, M16

Corrosion resistant coating for condenser coil fins

I03, I23, I52

Condenser coil protection grille

I04, I60

Protection grille or mesh on the condenser air-intake side

I05, I61

Chilled water connections up to unit's exterior side

I06

Victaulic-coupling on evaporator

I07

Chilled water connections with flanges

I08

Flow switch

I10

Heavy-duty thermal insulation of evaporator

I11

Water filter (delivered separately)

I12

Cannot be delivered for all unit sizes

GLWC1130-2480CA2.HE

GLAH4131-8321CD2 (LT)

GLAH0152-0612BD1 (LT)

GLAH0524-1204BD2 (LT)

GLWH0152-0612BD2

GLWH0604-1204BD2

GLWH0401-1902BA2

GLWH1130-4960CA2

GLWH1130-4960CA2.HT

GLFC2150-2482DA2 (SL)

GLWC1130-4960CA2

GLFC0604-1204BD2 (SL)

GLWC0401-1902BA2

GLFC0152-0612BD2 (SL)

GLWC0604-1204BD2

GLAC2150-3660CA2.HE

GLWC0152-0612BD2

GLAC2150-4840CA2.SL

GLRC4060-4160CD2

GLAC2150-4840CA2

GLRC2015-2061CD2

GLAC1542-2642BA2 (SL)

GLDC0604-1204BD2

GLAC1532-2632BA2 (SL)

GLDC0152-0612BD2

GLAC0751-1301BA2 (SL)

GLCU452-4060BC2 (.SL)

GLAC4131-8321CD2 (SL/HE)

GLCU2015-2051BC1

GLAC4061-4121CD2 (SL/HE)

Cannot be delivered for all unit sizes

GLAC2015-2070CD1/2

GLAC2015-2070CD1/2.SL

GLAC2015-2081CD1/2.HE

GAC/H(N,P)016-064FD1

Accessories code

GS(A,D/C,H)0011-0061FD5/FD1

Description

Installation of accessories
Pump for heavy-duty delivery head

I15

Compressor sound insulation

I17

Sound insulation of compressor section

I19

Horizontal air delivery ducts kit

I20, I29

Victaulic-coupling with a counter pipe (groove/external screw thread) without GLPE

I27

Victaulic-coupling with a counter pipe (groove/external screw thread) with GLPE

I28

Polyurethane varnish coating for Cu/Al heat exchanger

I18, I22, I51

Protective coating for Microchannel heat exchanger (MCHX)

I55, I56, I57

Sound-attenuated casing for reducing compressor noise level

I24

Sound-attenuated casing for reducing compressor noise level

I25

Water filter for condenser (delivered separately)

I30

3-Way valve for cooling water regulation

I31

Water connection from top (only for GLPE/GLPC)

I32

Victaulic coupling with counter pipe

I33

Victaulic coupling with counter pipe (without pumps - without .I39-.I43)

I34

Victaulic coupling with counter pipe (with GLPE - without .I39-.I43)

I35

Victaulic coupling with counter pipe (with GLPC - without .I39-.I43)

I36

Victaulic coupling with pipe counterpart (with 1 pump GLPE and GLPC - without .I39 - .I43)

I37

Victaulic coupling with pipe counterpart (with 3-4 pumps GLPE and GLPC - without .I39 - .I43)

I38

Water connection manifold for evaporator and condenser (no pumps)

I39

Water connection manifold for evaporator and condenser (with GLPE)

I40

Water connection manifold for evaporator and condenser (with GLPC)

I41

Water connection manifold for evaporator and condenser (with 1 pump GLPE and GLPC)

I42

Water connection manifold for evaporator and condenser (with 3-4 pumps GLPE and GLPC)

I43

Sound-attenuated casing for reducing compressor noise level

I44

Piping set for buffer tank

I45

Sound-attenuated casing for reducing compressor noise level

I47

Acoustic box for unit sound attenuation XL (-16dB(A) SLP)

I48

Protection for condenser deflecting bends

I53

Protective panel for unit display

I58

Refrigerating engineering accessories


Solenoid valve for liquid line

R01

Shut-off valve on compressor suction side

R02

Refrigeration connecting kit

R06

Condensing pressure control by variable fan speed

R07

Shut-off valve in high-pressure line

R10

Electronic expansion valve kit (10-12.3 kW cooling capacity)

R12

Suction and pressure gauge

R13

Double safety valve for low-pressure side

R17

Double safety valve for high-pressure side

R18

Double safety valves for high and low pressure sides

R19

Extended range of application up to -18 C outdoor temperature

R20, R21, R22

Condenser pressure regulation to -20 C

R23, R24, R25

Condenser pressure regulation to -20 C

R25

Mechanical Accessories
GLHM frost protection kit with electric heater

M05, M09

Assembly kit 2nd pump (serial switching)

M11

Modulating 2- or 3-way valve

M12

GLHM frost protection heating with heating element for piping systems

M13

Electric heating element for all hydraulic components

M14

Buffer tank

GSHM30

Operation for discharge temperatures below 0 C

O10

Unit packaging as open timber crate for chiller

O01

Packing of the unit with nylon cover

O11, O15

Lifting rods for unloading and shipping

O12

Unit stabilization for shipping

O13, O14

Extended range of application to -18 C outdoor temperature for wind-protected placement

O16, O17, O18

Extended range of application up to 50 C outdoor temperature

O19

Extended range of application up to -25 C outdoor temperature

O20

Operation with cold water-discharge temperatures up to 20 C

O21

Operation with chilled water outlet 20 C & air intake temperatures to 48 C

O22

Operation with chilled water outlet 20 C & air intake temperatures down to -25 C

O23

GLAC1532-2632BA2 (SL)
GLAC1542-2642BA2 (SL)
GLAC2150-4840CA2
GLAC2150-4840CA2.SL
GLAC2150-3660CA2.HE
GLFC0152-0612BD2 (SL)
GLFC0604-1204BD2 (SL)
GLFC2150-2482DA2 (SL)

GLRC2015-2061CD2

GLWH1130-4960CA2.HT

GLWH1130-4960CA2

GLWH0401-1902BA2

GLWH0604-1204BD2

GLWH0152-0612BD2

GLAH0524-1204BD2 (LT)

GLAH0152-0612BD1(LT)

GLAH4131-8321CD2 (.LT)

GLWC1130-2480CA2.HE

GLWC1130-4960CA2

GLWC0401-1902BA2

GLWC0604-1204BD2

GLWC0152-0612BD2

GLRC4060-4160CD2

GLDC0604-1204BD2

GLDC0152-0612BD2

GLCU4052-4060BC2 (.SL)

GLCU2015-2051BC1

GLAC0751-1301BA2 (SL)

GLAC4131-8321CD2 (SL/HE)

GLAC4061-4121CD2 (SL/HE)

First Service
Always at your side
Economical right from the start
The developments from GEA represent state-of-the-art technology. Our systems support
diverse applications that optimally conform to current criteria of cost effectiveness, safety,
and sustainability. Our products and services go far beyond pure technology. They are integrated into a comprehensive and in every respect customized service package. This program includes not only conventional services such as spare part delivery, maintenance,
and repair. It unites the consulting and engineering of a technology leader with customized
after-sales service and rapid response times. And this applies not only to installing new
equipment This service also applies for upgrading and optimizing old equipment, and provides you with perfect support in all project phases The functionality of the system is
secured over its entire service life.

Our services at a glance


Own heat exchanger

International service und support in experienced hands

production

Wherever you need us, we will be there for you in the shortest time. Throughout Europe,

Use of certified

a company-owned customer service ensures that you can enjoy the advantages of our units

products and components

at all times. In Germany alone, many technicians are ready on-call for rapid deployment.

Use of components from well-

All services are designed for absolute safety and reliability. On request, for example, a func-

known component manufac-

tion check of all GEA components can be carried out by our service force on location, sup-

turers

ported by an experienced GEA technician and the installer. This way our many years of

Short delivery times for spare

parts
Commissioning of new

facilities

functional know-how is passed on directly and personally. In this context, we should also
mention the training sessions which we offer for our air-conditioning solutions technology. Such training is a beneficial instrument for ensuring the lasting functionality and
availability of the systems.

Periodic servicing
Maintenance

A decision for quality

Factory trial run

A high quality standard is the basis and principle of all our services. All our service special-

Renovation and optimization

ists are highly experienced and devote themselves to their work with great diligence. Tech-

of old systems

nically and personally convincing: this is what you can expect from us.

Maintenance agreements

x74]

PR-2014-0100-DE nderungen vorbehalten K0-06/2014

Initial installation
Maintenance and servicing
Assembly services
Spare parts
Customer service
Consulting
Refurbishing
Training

PR-2014-0100-DE nderungen vorbehalten K0-06/2014

x75]

We live our values.


Excellence  Passion  Integrity  Responsibility !"#$

GEA Group is a global engineering company with multi-billion euro sales and operations in more than

        
 
 
       
process technology. GEA Group is listed in the STOXX Europe 600 Index.

x76]

www.gea-airtreatment.com

PR-2014-0100-DE nderungen vorbehalten K0-06/2014