Manual
. Outline
. Components
. Product Qualities
. Product Installation
. Button Functions
. Input Program
. How to use
. Cautions for safety
contents
. Outline
function is built in this equipment.
equipment.
running stops, the position of sample is same as first position.
motor and control board.
If running begins, you can monitor the data of each step by real
time graphic.
The system of this equipment is that motor spins and stops by
running data a user input, and BLDC servo motor with control
This equipment has a LED lamp that can know the status of alarm,
In system parameter you can set up maximum acceleration and
deceleration time, maximum speed, motor alarm logic, vacuum sensor
logic. You can also set a function in system parameter that if the
Memory storage program is 100 and each program has 100 steps.
User input program number, step number, motor speed(unit:RPM),
acceleration and deceleration time(Ramp, unit:second), motor
run time(unit : second) and fix a sample to a vacuum pump and run
start, vacuum in order to easily make maintenance and repair.
It contains a program menu which can monitor communication of a
. Components

1. main body



2. vacuum pump

3. vacuum chuck

4. vacuum hose
5. power cord
6. manual
. Product Qualities
ACE - 200
Bowl Size 235 m/m diameter
Bowl Material
Model
Rotation Speed
SUS 316
0 to 50 ~ 8,000 rpm
Vacuum Pump
Time
Spin Step
Recipes
Vacuum Input
Micom control
320 x 420 x 240 (mm)
Rotary vacuum pump
LCD(back light type)
Graphic function
Real time steps graphic
representation
Display
Power Input AC 220V , 50/60 Hz
Variable, 0.1 ~ 999sec
100 steps
100 recipes
-450 ~ -650 mmHg
System Controller
Dimensions (W*D*H)
. Product Installation


picture 1-1













"ON"





power switch
power cord
1. connect power cord, vacuum hose, power code for vacuum pump
on the main body backside like picture 1-1.
power cord for vacuum pump
(turn a cap clockwise and fix)
put groove of shaft and it of balt in chuck as a straight line
3. Fit the vacuum chuck to groove of shaft in main body.
2. Turn on power switch of main body backside.
vacuum hose
(put to the end)
. Button functions
: select a program menu
: running a process
: stop that process
: Running , deleting program
: when input step and room , moves a position of cursor
: initializing memory, deleting step
: Adding a step
: after input a step, program number , store the data and change into another screen
: changing a screen of step input, graphical <-> character screen.
~ : input numbers
: power of main body
: power of vacuum pump
: sensor adjusing a degree of vacuum
(status of being set up! Prohibit adjustment)
. Program input
1-1. pressing the button in initial screen moves you into the coding program.
1-2. press the program number in select program "[ ]" and press the button

program number in
coding
when move into next page
use these button
page number in coding
rpm user appointed
1-3. Input Rpm, Ramp, Time value in each step. Using button
after having put cursor(-) to coding program, press the button
, you move into next line.
rpm maintenance time
time to reach rpm value input (1~30 sec)
"Ramp"is acceleration and deceleration time of rpm(sec/3,000 rpm)
character screen.
1-5. by using button, data running screen can convert to graphic or
screen after press
1-4. after having finished value input in each step press the button .
(input value is stored, screen is converted to graphic screen)
after having finished data input you must
input deceleration time in the last room
TIP after having finished date input if press instead of
End Rpm "0"
you can run equipment in temporary storage status.
screen after press
. How to use
and start the coating process.



6-2. In case of overload of a motor, alarm lamp twinkles quickly.
- get off the power and re-start the process 10 seconds later.
button and run on equipment.
1. Prepare a sample and coating solution.
2. Place a sample on CHUCK and balance its center.
5. If the coating process is finished, open a cover and pick out the sample
6. Alarm function
6-1. If vacuum condition lacks, alarm lamp twinkles slowly.
after removing vacuum by pressing "vacuum".

if the vacuum status is stabilized, LED lamp lights.
cover the lid. After that, by pressing button("START" lamp is on)
- after recovering vacuum condition with normality, press

3. By pressing the front "vacuum power", turn it on and by
pressing ,fix the sample.
4. All the preparations are made, sprinkle coating solution on the sample and
. Cautions for safety
Do not give a forcible load or shock to equipment.
http://www.spincoater.net
4.Caution: Do not operate the process except the manual.
DONG AH TRADE CORP
turn off motor and vacuum pump switch for about 10 to 20
6.Caution: use a right chuck depending on size of sample. Using bad size
of sample may cause a risk for trouble or accident to happen.
minutes and re-start it.

5.Caution: If you are using it over a long time (more than 1 hour),
around equipment.
quick stop beyond the motor specification.
1.Danger : A misuse may cause very dangerous incidents,

including death or a severe wound.
2.Caution: Do not leave flammable matter or high pressure appliances
3.Caution: Do not make forcible operation as quick acceleration and